WorldWideScience

Sample records for beryllium measurement review

  1. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A

    2009-05-27

    Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

  2. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A.

    2008-12-17

    This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses on validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.

  3. BERYLLIUM MEASUREMENT IN COMMERCIALLY AVAILABLE WET WIPES

    Energy Technology Data Exchange (ETDEWEB)

    Youmans-Mcdonald, L.

    2011-02-18

    Analysis for beryllium by fluorescence is now an established method which is used in many government-run laboratories and commercial facilities. This study investigates the use of this technique using commercially available wet wipes. The fluorescence method is widely documented and has been approved as a standard test method by ASTM International and the National Institute for Occupational Safety and Health (NIOSH). The procedure involves dissolution of samples in aqueous ammonium bifluoride solution and then adding a small aliquot to a basic hydroxybenzoquinoline sulfonate fluorescent dye (Berylliant{trademark} Inc. Detection Solution Part No. CH-2) , and measuring the fluorescence. This method is specific to beryllium. This work explores the use of three different commercial wipes spiked with beryllium, as beryllium acetate or as beryllium oxide and subsequent analysis by optical fluorescence. The effect of possible interfering metals such as Fe, Ti and Pu in the wipe medium is also examined.

  4. What is a Beryllium Measurement? A Critical Look at Beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Charles Davis; Dan Field; John Hess; Dan Jensen

    2006-03-01

    DOE workplaces strive to comply with the 10 CFR 850.31(b)(1) surface concentration release criterion. The usual planning considerations for demonstrating compliance are these: how many swipes, and where; which sample preparation and analytical methods; what reporting limits; and what sample statistic to compare with the criterion. We have reviewed swipe samples from hundreds of Nevada Test Site workplaces: office buildings; experimental facilities; forward area field units; shops; and tunnels. Our experiences have led us to a critical examination of the inner workings of the measurement process itself, involving details generally taken for granted when those usual questions are asked. In this presentation we dissect the ICP-AES Be measurement process. We discuss calibration options and how they impact the distributions of analytical results. We look at distributions of blank results obtained from different labs, and discuss their relevance to determining reporting limits. We examine the way measurements are made from spectra, how that process impacts our understanding of the actual statistical distributions of Be measurements, and how interferences can affect Be measurements. Our objective is to gain sufficient confidence in the measurement process so that the usual questions will make sense and the survey results will be credible. Based on our observations, we offer these recommendations: prepare calibration samples in digested blank swipes; force the calibration line through (0,0); base reporting limits on field blank measurement distributions rather than 40 CFR 236 calculations; use, but do not believe, the usual lognormal distribution assumption; and avoid the 234.861 nm emission line.

  5. Beryllium processing technology review for applications in plasma-facing components

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R.G.; Jacobson, L.A.; Stanek, P.W.

    1993-07-01

    Materials research and development activities for the International Thermonuclear Experimental Reactor (ITER), i.e., the next generation fusion reactor, are investigating beryllium as the first-wall containment material for the reactor. Important in the selection of beryllium is the ability to process, fabricate and repair beryllium first-wall components using existing technologies. Two issues that will need to be addressed during the engineering design activity will be the bonding of beryllium tiles in high-heat-flux areas of the reactor, and the in situ repair of damaged beryllium tiles. The following review summarizes the current technology associated with welding and joining of beryllium to itself and other materials, and the state-of-the-art in plasma-spray technology as an in situ repair technique for damaged beryllium tiles. In addition, a review of the current status of beryllium technology in the former Soviet Union is also included.

  6. Measurement of the ultracold neutron loss coefficient in beryllium powder

    International Nuclear Information System (INIS)

    The ultracold neutron (UCN) reflection from beryllium powder at different slab thicknesses and different packing densities is measured. The reduced UCN loss coefficient η=(1.75±0.35)x10-4 for thermally untreated beryllium is extracted from experimental data. The formerly obtained experimental results on UCN reflection from beryllium after high temperature annealing are reconsidered. The loss coefficient η at room temperature in this case is obtained to be (6.4±2.5)x10-5, which is an order of magnitude higher than the theoretical one. The extraction of the loss coefficient from the experimental data is based on the modified diffusion theory where albedo reflection depends on packing density

  7. Nuclear charge radius measurements of radioactive beryllium isotopes

    CERN Multimedia

    2002-01-01

    We propose to measure the nuclear charge radii of the beryllium isotopes $^{7,9,10}$Be and the one-neutron halo isotope $^{11}$Be using laser spectroscopy of trapped ions. Ions produced at ISOLDE and ionized with the laser ion source will be cooled and bunched in the radio-frequency buncher of the ISOLTRAP experiment and then transferred into a specially designed Paul trap. Here, they will be cooled to temperatures in the mK range employing sympathetic and direct laser cooling. Precision laser spectroscopy of the isotope shift on the cooled ensemble in combination with accurate atomic structure calculations will provide nuclear charge radii with a precision of better than 3%. This will be the first model-independent determination of a one-neutron halo nuclear charge radius.

  8. Beryllium Toxicity

    Science.gov (United States)

    ... Favorites Del.icio.us Digg Facebook Google Bookmarks Yahoo MyWeb Beryllium Toxicity Patient Education Care Instruction Sheet ... Favorites Del.icio.us Digg Facebook Google Bookmarks Yahoo MyWeb Page last reviewed: May 23, 2008 Page ...

  9. Lifetime Measurements for Electric-Dipole △ n = 0 Transitions in the Beryllium-Like Sulfur

    Institute of Scientific and Technical Information of China (English)

    DU Shu-Bin; YANG Zhi-Hu; CHANG Hong-Wei; SU Hong

    2005-01-01

    @@ We have measured lifetimes of △n = 0 allowed transitions in beryllium-like sulfur using beam foil spectroscopic techniques. The measured values, derived from analysis of arbitrarily normalized decay curves, are presented and compared with theoretical calculations and previous measurements. Accurate probabilities have been determined by the well-known relationship.

  10. Measurement of the ultracold-neutron loss coefficient for beryllium powder

    International Nuclear Information System (INIS)

    Reflections of ultracold neutrons (UCN) from beryllium powder have been measured for various layer thickness and various packing densities. On the basis of the experimental data, the reduced UCN loss coefficient for the UCN reflected from the thermally untreated beryllium, η, is found to be η = (1.75 ± 0.35) x 10-4. The previously obtained data on the reflection of UCN from beryllium powder annealed at high temperature are reconsidered. the value obtained for η at room temperature is (6.4 ± 2.5) x 10-5, which exceeds the theoretical value by an order of magnitude. The analysis of the experimental data was carried out by using a modified diffusion theory in which the albedo reflection depends on the packing density

  11. Measurement of neutron yield by 62 MeV proton beam on a thick Beryllium target

    CERN Document Server

    Alba, R; Boccaccio, P; Celentano, A; Colonna, N; Cosentino, G; Del Zoppo, A; Di Pietro, A; Esposito, J; Figuera, P; Finocchiaro, P; Kostyukov, A; Maiolino, C; Osipenko, M; Ricco, G; Ripani, M; Viberti, C M; Santonocito, D; Schillaci, M

    2012-01-01

    In the framework of research on IVth generation reactors and high intensity neutron sources a low-power prototype neutron amplifier was recently proposed by INFN. It is based on a low-energy, high current proton cyclotron, whose beam, impinging on a thick Beryllium converter, produces a fast neutron spectrum. The world database on the neutron yield from thick Beryllium target in the 70 MeV proton energy domain is rather scarce. The new measurement was performed at LNS, covering a wide angular range from 0 to 150 degrees and an almost complete neutron energy interval. In this contribution the preliminary data are discussed together with the proposed ADS facility.

  12. (n,p) emission channeling measurements on ion-implanted beryllium

    CERN Multimedia

    Jakubek, J; Uher, J

    2007-01-01

    We propose to perform emission-channeling measurements using thermal neutron induced proton emission from ion-implanted $^{7}$Be. The physics questions addressed concern the beryllium doping of III-V and II-VI semiconductors and the host dependence of the electron capture half-life of $^{7}$Be.

  13. Comprehensive Measurement of Neutron Yield Produced by 62 MeV Protons on Beryllium Target

    International Nuclear Information System (INIS)

    A low-power prototype of neutron amplifier, based on a 70 MeV, high current proton cyclotron being installed at LNL for the SPES RIB facility, was recently proposed within INFN-E project. This prototype uses a thick Beryllium converter to produce a fast neutron spectrum feeding a sub-critical reactor core. To complete the design of such facility the new measurement of neutron yield from a thick Beryllium target was performed at LNS. This measurement used liquid scintillator detectors to identify produced neutrons by Pulse Shape Discrimination and Time of Flight technique to measure neutron energy in the range 0.5-62 MeV. To extend the covered neutron energy range 3He detector was used to measure neutrons below 0.5 MeV. The obtained yields were normalized to the charge deposited by the proton beam on the metallic Beryllium target. These techniques allowed to achieve a wide angular coverage from 0 to 150 degrees and to explore almost complete neutron energy interval. (authors)

  14. Degassing measurement for beryllium exposed to D{sub 2} atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Markin, A.V.; Zakharov, A.P. [Russian Academy of Sciences, Moscow (Russian Federation). Inst. of Physical Chemistry

    1998-01-01

    A possibility of the correct determination of deuterium solubility and diffusivity in Be on the basis of degassing experiments is demonstrated. It has been found that the main fraction (above 90%) of deuterium retained under D{sub 2} exposure is removed under slight electropolishing (descaling of {approx} 2-5 {mu}m) of the samples before TDS measurement. This deuterium seems to be located in the near surface oxide layers formed during the exposure as a result of interaction of beryllium with oxygen containing molecules of residual gas. In all degassing runs the diffusion of deuterium in the bulk of beryllium samples was not a limited-stage of gas release. (author)

  15. RF surface resistance of copper-on-beryllium at cryogenic temperatures measured by a 22-GHZ demountable cavity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jianfei; Krawczyk, F. L. (Frank L.); Kurennoy, S. (Sergey); Schrage, D. L. (Dale L.); Shapiro, A. H. (Alan H.); Tajima, T. (Tsuyoshi); Wood R. L. (Richard L.)

    2003-01-01

    A 22-GHz demountable cavity on the cold head of a compact refrigerator system was used to measure the RF performance of several coppt:r-plated Beryllium samples. The cavity inner surfce was treated by chemical polishing and heat treatment., as well as an OFE copper coupon to provide a baseline for comparison. The measured surhce resistance was reasonable and repeatable during either cooling or warming. Materials tested included four grades of Beryllium, OFE copper, alumina-dispersion strengthened copper (Glidcop), and Cu-plated versions of all of the above. Two coupons, Cuplated on Beryllium 0-30 and 1-70, offered comparable surface resistance to pure OFE copper or Cu-plated Glidcop. The RF surface resistance of Cu-on-Beryllium samples at cryogenic temperatures is reported together with that of other reference materials.

  16. Beryllium development programme in India

    International Nuclear Information System (INIS)

    India has fairly large deposits of beryl. The requirement of beryllium and copper-beryllium alloys in space and electronic industries has provided the incentive for the setting up of an indigenous base for the development of beryllium process metallurgy. The paper presents the developmental work carried out, in the Metallurgy Division of the Bhabha Atomic Research Centre, on the preparation of beryllium metal and its alloys starting from Indian beryl. A laboratory facility incorporating essential precautionary measures has been set up for the safe handling of beryllium and its compounds. Based on the laboratory investigations a flow-sheet suitable to Indian conditions has been developed. The flow-sheet involves preparation of anhydrous beryllium fluoride from beryl through the silico-fluoride route, magnesiothermic reduction of beryllium fluoride for the production of beryllium metal or its master alloy with copper or aluminium, and fabrication of beryllium metal. (author)

  17. Beryllium technology workshop, Clearwater Beach, Florida, November 20, 1991

    International Nuclear Information System (INIS)

    This report discusses the following topics: beryllium in the ITER blanket; mechanical testing of irradiated beryllium; tritium release measurements on irradiated beryllium; beryllium needs for plasma-facing components; thermal conductivity of plasma sprayed beryllium; beryllium research at the INEL; Japanese beryllium research activities for in-pile mockup tests on ITER; a study of beryllium bonding of copper alloy; new production technologies; thermophysical properties of a new ingot metallurgy beryllium product line; implications of beryllium:steam interactions in fusion reactors; and a test program for irradiation embrittlement of beryllium at JET

  18. X-ray Thomson scattering measurements of density and temperature in shock-compressed beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H J; Neumayer, P; Castor, J; Doppner, T; Falcone, R W; Fortmann, C; Hammel, B A; Kritcher, A L; Landen, O L; Lee, R W; Meyerhofer, D D; Munro, D H; Redmer, R; Regan, S P; Weber, S; Glenzer, S H

    2008-08-05

    We present the first x-ray scattering measurements of the state of compression and heating in laser irradiated solid beryllium. The scattered spectra at two different angles show Compton and plasmon features indicating a dense Fermi-degenerate plasma state with a Fermi energy above 30 eV and with temperatures in the range of 10 eV to 15 eV. These measurements indicate compression by a factor of three in agreement with Hugoniot data and detailed radiation hydrodynamic modeling.

  19. Beryllium 1989

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    The Roskill report on beryllium gives information on the occurrence and reserves, production technology, geographic distribution, consumption and end-uses, stocks, prices and beryllium and health. There is an appendix on international trade statistics. (author).

  20. Measurement of charged particle production from 450 GeV/c protons on beryllium

    CERN Document Server

    Ambrosini, G; Bernier, K; Biino, C; Bonesini, M; Bonivento, W; Borer, K; Brooijmans, G; Catanesi, M G; Collazuol, G; Daniels, D C; Dittus, F B; Elsener, K; Godley, A; Grant, A; Grégoire, G; Guglielmi, A M; Kabana, S; Kabana, R; Klingenberg, R; Lehmann, G; Lindén, T; Linssen, Lucie; Marchionni, A; Mishra, S R; Moffitt, L; Moser, U; Palladino, Vittorio; Pietropaolo, F; Pretzl, Klaus P; Pullia, Antonio; Radicioni, E; Ragazzi, S; Stachel, J; Sergiampietri, F; Soler, F J P; Stoffel, F; Tabarelli de Fatis, T; Terranova, F; Tovey, Stuart N; Tsesmelis, E; Weber, M

    1999-01-01

    This paper presents the results on charged particle yields and production ratios as measured by the NA56/SPY experiment for 450 GeV/c proton interactions on beryllium targets. The data cover a secondary momentum range from 7 GeV/c to 135 GeV/c and $p_T$ values up to 600~MeV/c. An experimental accuracy on the measured yields in the range from $5 \\%$ to $10 \\%$, depending on the beam momentum, and around $3 \\%$ for the particle production ratios has been achieved. These measurements are relevant for a precise evaluation of fluxes and composition of neutrino beams at accelerators. Results on the target thickness and shape dependence are also reported. Inclusive invariant cross sections in the forward direction have been derived. %An experimental accuracy of about 3\\% has been achieved on the measurements %of the $K/\\pi$ production ratios. These results will greatly reduce %the uncertainty on the estimation of the $\

  1. Beryllium Desorption from Sediments

    Science.gov (United States)

    Boschi, V.; Willenbring, J. K.

    2015-12-01

    Beryllium isotopes have provided a useful tool in the field of geochronology and geomorphology over the last 25 years. The amount of cosmogenic meteoric 10Be and native 9Be absorbed to soils often scales with the residence time and chemical weathering of sediments in a landscape, respectively. Thus, the concentrations in river sediment may be used to quantify the denudation of specific watersheds. When deposited in ocean sediment, these concentrations are thought to record the history of denudation on Earth over the last ~10 Ma. The use of both isotopes often relies on the premise of beryllium retention to sediment surfaces in order to preserve a landscape's erosion and weathering signature. Changes in setting, en route from the soil to fluvial system to the ocean, can cause beryllium desorption and may preclude some applications of the 10Be/9Be system. Four mechanisms were tested to determine the desorption potential of beryllium including a reduction in pH, an increase in ionic strength and complexation with soluble organic and inorganic species. These processes have the potential to mobilize beryllium into solution. For example, by both reducing the pH and increasing the ionic strength, competition for adsorption sites increases, potentially liberating beryllium from the sediment surface. In addition, organic and inorganic ligands can complex beryllium causing it to become mobilized. To determine which of these alterations influence beryllium desorption and to quantify the effect, we prepared separate solutions of beryllium bound to minerals and organic compounds and measured beryllium concentrations in solution before and after adjusting the pH, ionic strength, and changing inorganic and organic ligand concentrations. We conclude from our observations that overall, beryllium sorbed to organic compounds was more resistant to desorption relative to mineral-associated beryllium. Among the methods tested, a reduction in pH resulted in the greatest amount of

  2. The Karlsruhe Neutron Transmission Experiment (KANT): Spherical shell transmission measurements with 14 MeV neutrons on beryllium

    International Nuclear Information System (INIS)

    This is a set of viewgraphs (no additional text) of a presentation on spherical shell transmission measurements with 14 MeV neutrons on beryllium; the cross for 9Be(n,2n)2α for the energy range between threshold (1.85 MeV) and 20 MeV neutron energy is measured and the measurement is compared with the literature. Also, neutron leakage multiplication in spherical Be shells with various thicknesses are presented. Figs, tabs

  3. Beryllium Concentrations at European Workplaces: Comparison of 'Total' and Inhalable Particulate Measurements.

    Science.gov (United States)

    Kock, Heiko; Civic, Terence; Koch, Wolfgang

    2015-07-01

    A field study was carried out in order to derive a factor for the conversion of historic worker exposure data on airborne beryllium (Be) obtained by sampling according to the 37-mm closed faced filter cassette (CFC) 'total' particulate method into exposure concentration values to be expected when sampling using the 'Gesamtstaubprobenahmesystem' (GSP) inhalable sampling convention. Workplaces selected to represent the different copper Be work processing operations that typically occur in Germany and the EU were monitored revealing a broad spectrum of prevailing Be size distributions. In total, 39 personal samples were taken using a 37-mm CFC and a GSP worn side by side for simultaneous collection of the 'total' dust and the inhalable particulates, respectively. In addition, 20 static general area measurements were carried out using GSP, CFC, and Respicon samplers in parallel, the latter one providing information on the extra-thoracic fraction of the workplace aerosol. The study showed that there is a linear relationship between the concentrations measured with the CFC and those measured with the GSP sampler. The geometric mean value of the ratios of time-weighted average concentrations determined from GSP and CFC samples of all personal samples was 2.88. The individual values covered a range between 1 and 17 related to differences in size distributions of the Be-containing particulates. This was supported by the area measurements showing that the conversion factor increases with increasing values of the extra-thoracic fraction covering a range between 0 and 79%. PMID:25808693

  4. Extraction and optical fluorescence method for the measurement of trace beryllium in soils.

    Science.gov (United States)

    Agrawal, Anoop; Cronin, John P; Agrawal, Akshay; Tonazzi, Juan C L; Adams, Lori; Ashley, Kevin; Brisson, Michael J; Duran, Brandy; Whitney, Gary; Burrell, Anthony K; McCleskey, T Mark; Robbins, James; White, Kenneth T

    2008-03-15

    Beryllium metal and beryllium oxide are important industrial materials used in a variety of applications in the electronics, nuclear energy, and aerospace industries. These materials are highly toxic, they must be disposed of with care, and exposed workers need to be protected. Recently, a new analytical method was developed that uses dilute ammonium bifluoride for extraction of beryllium and a high quantum yield optical fluorescence reagent to determine trace amounts of beryllium in airborne and surface samples. The sample preparation and analysis procedure was published by both ASTM International and the National Institute for Occupational Safety and Health (NIOSH). The main advantages of this method are its sensitivity, simplicity, use of lower toxicity materials, and low capital costs. Use of the technique for analyzing soils has been initiated to help meet a need at several of the U.S. Department of Energy legacy sites. So far this work has mainly concentrated on developing a dissolution protocol for effectively extracting beryllium from a variety of soils and sediments so that these can be analyzed by optical fluorescence. Certified reference materials (CRM) of crushed rock and soils were analyzed for beryllium content using fluorescence, and results agree quantitatively with reference values.

  5. Beryllium. Beryllium oxide, obtention and properties. Pt.4

    International Nuclear Information System (INIS)

    As a continuation of the 'Beryllium' series this work reviews several methods of high purity beryllia production. Diverse methods of obtention and purification from different beryllium compounds are described. Some chemical, mechanical and electrical properties related with beryllia obtention methods are summarized. (Author)

  6. Mechanical performance of irradiated beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Scaffidi-Argentina, F.; Dalle-Donne, M.; Werle, H. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Neutronenphysik und Reaktortechnik

    1998-01-01

    For the Helium Cooled Pebble Bed (HCPB) Blanket, which is one of the two reference concepts studied within the European Fusion Technology Programme, the neutron multiplier consists of a mixed bed of about 2 and 0.1-0.2 mm diameter beryllium pebbles. Beryllium has no structural function in the blanket, however microstructural and mechanical properties are important, as they might influence the material behavior under neutron irradiation. The EXOTIC-7 as well as the `Beryllium` experiments carried out in the HFR reactor in Petten are considered as the most detailed and significant tests for investigating it. This paper reviews the present status of beryllium post-irradiation examinations performed at the Forschungszentrum Karlsruhe with samples from these irradiation experiments, emphasizing the effects of irradiation of essential material properties and trying to elucidate the processes controlling the property changes. The microstructure, the porosity distribution, the impurity content, the behavior under compression loads and the compatibility of the beryllium pebbles with lithium orthosilicate (Li{sub 4}SiO{sub 4}) during the in-pile irradiation are presented and critically discussed. Qualitative information on ductility and creep obtained by hardness-type measurements are also supplied. (author)

  7. Beryllium Related Matter

    Energy Technology Data Exchange (ETDEWEB)

    Gaylord, R F

    2008-12-23

    In recent months, LLNL has identified, commenced, and implemented a series of interim controls, compensatory measures, and initiatives to ensure worker safety, and improve safety processes with regards to potential worker exposure to beryllium. Many of these actions have been undertaken in response to the NNSA Independent Review (COR-TS-5/15/2008-8550) received by LLNL in November of 2008. Others are the result of recent discoveries, events or incidents, and lessons learned, or were scheduled corrective actions from earlier commitments. Many of these actions are very recent in nature, or are still in progress, and vary in the formality of implementation. Actions are being reviewed for effectiveness as they progress. The documentation of implementation, and review of effectiveness, when appropriate, of these actions will be addressed as part of the formal Corrective Action Plan addressing the Independent Review. The mitigating actions taken fall into the following categories: (1) Responses to specific events/concerns; (2) Development of interim controls; (3) Review of ongoing activities; and (4) Performance improvement measures.

  8. Dosimetry of High-Energy Protons by Measurement of Beryllium-7 Formed in the Tissues

    International Nuclear Information System (INIS)

    In the course of biological experiments at the CERN cyclotron at Geneva (using 600 MeV protons) and the Saturne synchrotron at the Saclay Nuclear Studies Centre, the radioactivity induced in living beings was investigated by gamma-spectrography. Whereas most of the induced radioisotopes (gamma emitters) are short-lived, the beryllium-7 produced by spallation reactions on, in particular, oxygen, carbon and nitrogen atoms, has an activity peak which stands out abruptly from the spectrum as a whole at the 479-keV level. As its half-life is 54. 5 d, it can be recorded for a sufficiently long time. An experiment carried out with Whitsar rats given whole-body exposures of between 400 and 800 rad with 600-MeV protons and of 200 to 1000 rad with 3-GeV protons, disclosed a linear response of the Be7 activity in relation to the dose absorbed per gram of tissue. The authors compare their experimental results with the activities calculated in terms of energy on the basis of published cross-sections. The accidental exposure of human beings to proton beams can only be local. Exposure of the heads of Fauve de Bourgogne rabbits weighing approximately 2 kg show that the activity measured on the head, in relation to the rest of the body, is of the order of 1.8 ± 5. Be7 can be detected during the first days in spite of some diffusion. Relative dosimetry, indicating the scale of the accidental exposure received, is therefore possible. (author)

  9. Preliminary proposal for a beryllium technology program for fusion applications

    International Nuclear Information System (INIS)

    The program was designed to provide the answers to the critical issues of beryllium technology needed in fusion blanket designs. The four tasks are as follows: (1) Beryllium property measurements needed for fusion data base. (2) Beryllium stress relaxation and creep measurements for lifetime modelling calculations. (3) Simplified recycle technique development for irradiated beryllium. (4) Beryllium neutron multiplier measurements using manganese bath absolute calibration techniques

  10. Measurement of the thermal conductivity and heat transfer coefficient of a binary bed of beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Donne, M.D.; Piazza, G. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Neutronenphysik und Reaktortechnik; Goraieb, A.; Sordon, G.

    1998-01-01

    The four ITER partners propose to use binary beryllium pebble bed as neutron multiplier. Recently this solution has been adopted for the ITER blanket as well. In order to study the heat transfer in the blanket the effective thermal conductivity and the wall heat transfer coefficient of the bed have to be known. Therefore at Forschungszentrum Karlsruhe heat transfer experiments have been performed with a binary bed of beryllium pebbles and the results have been correlated expressing thermal conductivity and wall heat transfer coefficients as a function of temperature in the bed and of the difference between the thermal expansion of the bed and of that of the confinement walls. The comparison of the obtained correlations with the data available from the literature show a quite good agreement. (author)

  11. Beryllium Concentrations at European Workplaces: Comparison of ‘Total’ and Inhalable Particulate Measurements

    OpenAIRE

    Kock, Heiko; Civic, Terence; Koch, Wolfgang

    2015-01-01

    A field study was carried out in order to derive a factor for the conversion of historic worker exposure data on airborne beryllium (Be) obtained by sampling according to the 37-mm closed faced filter cassette (CFC) ‘total’ particulate method into exposure concentration values to be expected when sampling using the ‘Gesamtstaubprobenahmesystem’ (GSP) inhalable sampling convention. Workplaces selected to represent the different copper Be work processing operations that typically occur in Germa...

  12. Thermal behavior and temperature measurements of melting beryllium plasma-facing components exposed to high heat flux

    International Nuclear Information System (INIS)

    The emissivity of metallic materials is low and varies with temperature and wavelength inducing errors on surface temperature measurements. High heat flux experiments on beryllium were carried out to investigate the thermal behavior of bulk Be tiles. Thermal modeling aiming at determining the surface and bulk temperatures have been performed using ANSYS®. A Be tile was exposed to heat flux with power density ranging between 1 and 7 MW/m2. Surface temperatures were measured using an infrared camera in the 3–5 μm range and two-color pyrometers, one at short wavelengths (1.5–1.7 μm) and one at mid IR range wavelengths (2–4 μm) range. Both the IR camera and two-color pyrometers do not provide accurate temperature measurements on melted Be due to changes in the emissivities and emissivity ratio induced by surface modifications

  13. Benchmark Evaluation of Fuel Effect and Material Worth Measurements for a Beryllium-Reflected Space Reactor Mockup

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, Margaret A. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Center for Space Nuclear Research; Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-02-01

    The critical configuration of the small, compact critical assembly (SCCA) experiments performed at the Oak Ridge Critical Experiments Facility (ORCEF) in 1962-1965 have been evaluated as acceptable benchmark experiments for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. The initial intent of these experiments was to support the design of the Medium Power Reactor Experiment (MPRE) program, whose purpose was to study “power plants for the production of electrical power in space vehicles.” The third configuration in this series of experiments was a beryllium-reflected assembly of stainless-steel-clad, highly enriched uranium (HEU)-O2 fuel mockup of a potassium-cooled space power reactor. Reactivity measurements cadmium ratio spectral measurements and fission rate measurements were measured through the core and top reflector. Fuel effect worth measurements and neutron moderating and absorbing material worths were also measured in the assembly fuel region. The cadmium ratios, fission rate, and worth measurements were evaluated for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. The fuel tube effect and neutron moderating and absorbing material worth measurements are the focus of this paper. Additionally, a measurement of the worth of potassium filling the core region was performed but has not yet been evaluated Pellets of 93.15 wt.% enriched uranium dioxide (UO2) were stacked in 30.48 cm tall stainless steel fuel tubes (0.3 cm tall end caps). Each fuel tube had 26 pellets with a total mass of 295.8 g UO2 per tube. 253 tubes were arranged in 1.506-cm triangular lattice. An additional 7-tube cluster critical configuration was also measured but not used for any physics measurements. The core was surrounded on all side by a beryllium reflector. The fuel effect worths were measured by removing fuel tubes at various radius. An accident scenario

  14. Beryllium usage in fusion blankets and beryllium data needs

    International Nuclear Information System (INIS)

    Increasing numbers of designers are choosing beryllium for fusion reactor blankets because it, among all nonfissile materials, produces the highest number (2.5 neutron in an infinite media) of neutrons per 14-MeV incident neutron. In amounts of about 20 cm of equivalent solid density, it can be used to produce fissile material, to breed all the tritium consumed in ITER from outboard blankets only, and in designs to produce Co-60. The problem is that predictions of neutron multiplication in beryllium are off by some 10 to 20% and appear to be on the high side, which means that better multiplication measurements and numerical methods are needed. The n,2n reactions result in two helium atoms, which cause radiation damage in the form of hardening at low temperatures (300/degree/C). The usual way beryllium parts are made is by hot pressing the powder. A lower cost method is to cold press and then sinter. There is no radiation damage data on this form of beryllium. The issues of corrosion, safety relative to the release of the tritium built-up inside beryllium, and recycle of used beryllium are also discussed. 10 figs

  15. Recommended design correlations for S-65 beryllium

    International Nuclear Information System (INIS)

    The properties of tritium and helium behavior in irradiated beryllium are reviewed, along with the thermal-mechanical properties needed for ITER design analysis. Correlations are developed to describe the performance of beryllium in a fusion reactor environment. While this paper focuses on the use of beryllium as a plasma-facing component (PFC) material, the correlations presented here can also be used to describe the performance of beryllium as a neutron multiplier for a tritium breeding blanket. The performance properties for beryllium are subdivided into two categories: properties which do not change with irradiation damage to the bulk of the material; and properties which are degraded by neutron irradiation. The approach taken in developing properties correlations is to describe the behavior of dense, pressed S-65 beryllium as a function of temperature. As there are essentially no data on the performance of porous and/or irradiated S-65 beryllium, the degradation of properties with as-fabricated porosity and irradiation are determined form the broad data base on S-200F, as well as other types and grades, and applied to S-65 beryllium by scaling factors. The resulting correlations can be used for Be produced by vacuum hot pressing (VHP) and cold-pressing (CP)/sintering(S)/hot-isostatic-pressing(HIP). The performance of plasma-sprayed beryllium is discussed but not quantified

  16. An estimate of the stratospheric contribution to springtime tropospheric ozone maxima using TOPSE measurements and beryllium-7 simulations

    Science.gov (United States)

    Allen, Dale J.; Dibb, Jack E.; Ridley, Brian; Pickering, Kenneth E.; Talbot, Robert W.

    2003-02-01

    Measurements of tropospheric ozone (O3) between 30°N and 70°N show springtime maxima at remote locations. The contribution of seasonal changes in stratosphere-troposphere exchange (STE) to these maxima was investigated using measurements from the Tropospheric Ozone Production about the Spring Equinox Experiment (TOPSE) campaign and the beryllium-7 (7Be) distribution from a calculation driven by fields from the Goddard Earth Observing System Data Assimilation System (GEOS DAS). Comparison with TOPSE measurements revealed that upper tropospheric model-calculated 7Be mixing ratios were reasonable (a change from previous calculations) but that lower tropospheric mixing ratios were too low most likely due to an overestimation of scavenging. Temporal fluctuations were well captured although their amplitudes were often underestimated. Analysis of O3 measurements indicated that O3 mixing ratios increased by 5-10% month-1 for θ underworld) and by 10-15% month-1 for θ > 300 K (the tropospheric middleworld). 7Be mixing ratios decreased with time for θ 300 K. Model-calculated middleworld increases of 7Be were a factor of 2 less than measured increases. 7Be with a stratospheric source (strat-7Be) increased by 4.6-8.8% month-1 along TOPSE flight paths within the tropospheric middleworld. Increases in strat-7Be were not seen along TOPSE flight paths in the underworld. Assuming changes in tropospheric O3 with a stratospheric source are the same as changes in strat-7Be and that 50% of O3 in the region of interest is produced in the stratosphere, changes in STE explain 20-60% of O3 increases in the tropospheric middleworld and less than 33% of O3 increases in the underworld.

  17. Beryllium facilities in India

    International Nuclear Information System (INIS)

    Due to its unique combination of physical, mechanical, thermal and nuclear properties, beryllium is indispensable for many applications in the fields of nuclear and space sciences. Beryllia and copper beryllium alloys have also found extensive applications in the electrical and electronic industries. Beryllium facilities at Bhabha Atomic Research Centre (BARC) have been set up to meet indigenous requirements for these materials. Besides developing beryllium technology, the project team has also designed and developed a number of special purpose equipment. (Author)

  18. The uses and adverse effects of beryllium on health

    Directory of Open Access Journals (Sweden)

    Cooper Ross

    2009-01-01

    Full Text Available Context: This review describes the health effects of beryllium exposure in the workplace and the environment. Aim: To collate information on the consequences of occupational and environmental exposure to beryllium on physiological function and well being. Materials and Methods: The criteria used in the current review for selecting articles were adopted from proposed criteria in The International Classification of Functioning, Disability, and Health. Articles were classified based on acute and chronic exposure and toxicity of beryllium. Results: The proportions of utilized and nonutilized articles were tabulated. Years 2001-10 gave the greatest match (45.9% for methodological parameters, followed by 27.71% for 1991-2000. Years 1971-80 and 1981-90 were not significantly different in the information published and available whereas years 1951-1960 showed a lack of suitable articles. Some articles were published in sources unobtainable through requests at the British Library, and some had no impact factor and were excluded. Conclusion: Beryllium has some useful but undoubtedly harmful effects on health and well-being. Measures need to be taken to prevent hazardous exposure to this element, making its biological monitoring in the workplace essential.

  19. Neutron irradiation of beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Gelles, D.S.; Ermi, R.M. [Pacific Northwest National Lab., Richland, WA (United States); Tsai, H. [Argonne National Lab., IL (United States)

    1998-03-01

    Seven subcapsules from the FFTF/MOTA 2B irradiation experiment containing 97 or 100% dense sintered beryllium cylindrical specimens in depleted lithium have been opened and the specimens retrieved for postirradiation examination. Irradiation conditions included 370 C to 1.6 {times} 10{sup 22} n/cm{sup 2}, 425 C to 4.8 {times} 10{sup 22} n/cm{sup 2}, and 550 C to 5.0 {times} 10{sup 22} n/cm{sup 2}. TEM specimens contained in these capsules were also retrieved, but many were broken. Density measurements of the cylindrical specimens showed as much as 1.59% swelling following irradiation at 500 C in 100% dense beryllium. Beryllium at 97% density generally gave slightly lower swelling values.

  20. Beryllium chemistry and processing

    CERN Document Server

    Walsh, Kenneth A

    2009-01-01

    This book introduces beryllium; its history, its chemical, mechanical, and physical properties including nuclear properties. The 29 chapters include the mineralogy of beryllium and the preferred global sources of ore bodies. The identification and specifics of the industrial metallurgical processes used to form oxide from the ore and then metal from the oxide are thoroughly described. The special features of beryllium chemistry are introduced, including analytical chemical practices. Beryllium compounds of industrial interest are identified and discussed. Alloying, casting, powder processing, forming, metal removal, joining and other manufacturing processes are covered. The effect of composition and process on the mechanical and physical properties of beryllium alloys assists the reader in material selection. The physical metallurgy chapter brings conformity between chemical and physical metallurgical processing of beryllium, metal, alloys, and compounds. The environmental degradation of beryllium and its all...

  1. Thermal fatigue of beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Deksnis, E.; Ciric, D.; Falter, H. [JET Joint undertaking, Abingdon (United Kingdom)] [and others

    1995-09-01

    Thermal fatigue life of S65c beryllium castellated to a geometry 6 x 6 x (8-10)mm deep has been tested for steady heat fluxes of 3 MW/m{sup 2} to 5 MW/m{sup 2} and under pulsed heat fluxes (10-20 MW/m{sup 2}) for which the time averaged heat flux is 5 MW/m{sup 2}. These tests were carried out in the JET neutral beam test facility A test sequence with peak surface temperatures {le} 600{degrees}C produced no visible fatigue cracks. In the second series of tests, with T{sub max} {le} 750{degrees}C evidence for fatigue appeared after a minimum of 1350 stress cycles. These fatigue data are discussed in view of the observed lack of thermal fatigue in JET plasma operations with beryllium PFC. JET experience with S65b and S65c is reviewed; recent operations with {Phi} = 25 MW/m{sup 2} and sustained melting/resolidification are also presented. The need for a failure criterion for finite element analyses of Be PFC lifetimes is discussed.

  2. New measurements of spontaneous transition probabilities for beryllium-like ions

    International Nuclear Information System (INIS)

    The authors describe measurements of spectral line intensities for pairs of transitions having common upper levels and thus derive the branching ratios of their spontaneous radiative transition probabilities. These are then combined with the results of measurements of the radiative lifetimes of the upper levels by other authors to obtain values of the individual transition probabilities. The results are for transitions in NIV, OV and NeVII and are given with a claimed accuracy of between 7% and 38%. These are compared with values calculated theoretically. For some of the simpler electric dipole transitions good agreement is found. On the other hand for some of the other transitions which in certain cases are only possible because of configuration interaction disparities between the present measurements and theory are as large as x5. (author)

  3. Measurement of the ratio of Σ0 to Λ0 inclusive production by 28.5 GeV/c protons on beryllium

    International Nuclear Information System (INIS)

    The ratio of the cross section for Σ0 inclusive production to the cross section for Λ0 inclusive production has been measured with 28.5 GeV/c protons incident on a beryllium target at an average laboratory production angle of 40. This ratio was measured to be 0.278+-0.011+-0.05 where the uncertainties are statistical and systematic in that order. The ratio does not depend strongly on the momentum of the produced particle between 10 and 24 GeV/c. The effect of Σ0 contamination on previous determinations of the polarization of inclusively produced Λ0's is discussed. (orig.)

  4. Precision Measurement of the Beryllium-7 Solar Neutrino Interaction Rate in Borexino

    Science.gov (United States)

    Saldanha, Richard Nigel

    Solar neutrinos, since their first detection nearly forty years ago, have revealed valuable information regarding the source of energy production in the Sun, and have demonstrated that neutrino oscillations are well described by the Large Mixing Angle (LMA) oscillation parameters with matter interactions due to the Mikheyev-Smirnov-Wolfenstein (MSW) effect. This thesis presents a precision measurement of the 7Be solar neutrino interaction rate within Borexino, an underground liquid scintillator detector that is designed to measure solar neutrino interactions through neutrino-electron elastic scattering. The thesis includes a detailed description of the analysis techniques developed and used for this measurement as well as an evaluation of the relevant systematic uncertainties that affect the precision of the result. The rate of neutrino-electron elastic scattering from 0.862 MeV 7Be neutrinos is determined to be 45.4 +/- 1.6 (stat) +/- 1.5 (sys) counts/day/100 ton. Due to extensive detector calibrations and improved analysis methods, the systematic uncertainty in the interaction rate has been reduced by more than a factor of two from the previous evaluation. In the no-oscillation hypothesis, the interaction rate corresponds to a 0.862 MeV 7Be electron neutrino flux of (2.75 +/- 0.13) x 10 9 cm-2 sec-1. Including the predicted neutrino flux from the Standard Solar Model yields an electron neutrino survival probability of Pee 0.51 +/- 0.07 and rules out the no-oscillation hypothesis at 5.1sigma The LMA-MSW neutrino oscillation model predicts a transition in the solar Pee value between low ( 10 MeV) energies which has not yet been experimentally confirmed. This result, in conjunction with the Standard Solar Model, represents the most precise measurement of the electron neutrino survival probability for solar neutrinos at sub-MeV energies.

  5. Recommended design correlations for S-65 beryllium

    International Nuclear Information System (INIS)

    The properties of tritium and helium behavior in irradiated beryllium are reviewed, along with the thermal-mechanical properties needed for ITER design analysis. Correlations are developed to describe the performance of beryllium in a fusion reactor environment. While this paper focuses on the use of beryllium as a plasma-facing component (PFC) material, the correlations presented here can also be used to describe the performance of beryllium as a neutron multiplier for a tritium breeding blanket. The performance properties for beryllium are subdivided into two categories: properties which do not change with irradiation damage to the bulk of the material; and properties which are degraded by neutron irradiation. The irradiation-independent properties described within are: thermal conductivity, specific heat capacity, thermal expansion, and elastic constants. Irradiation-dependent properties include: yield strength, ultimate tensile strength, plastic tangent modulus, uniform and total tensile elongation, thermal and irradiation-induced creep strength, He-induced swelling and tritium retention/release. The approach taken in developing properties correlations is to describe the behavior of dense, pressed S-65 beryllium -- the material chosen for ITER PFC application -- as a function of temperature. As there are essentially no data on the performance of porous and/or irradiated S-65 beryllium, the degradation of properties with as-fabricated porosity and irradiation are determined from the broad data base on S-200F, as well as other types and grades, and applied to S-65 beryllium by scaling factors. The resulting correlations can be used for Be produced by vacuum hot pressing (VHP) and cold-pressing (CP)/sintering(S)/hot-isostatic-pressing (HIP). The performance of plasma-sprayed beryllium is discussed but not quantified

  6. Recommended design correlations for S-65 beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Billone, M.C. [Argonne National Lab., IL (United States)

    1995-09-01

    The properties of tritium and helium behavior in irradiated beryllium are reviewed, along with the thermal-mechanical properties needed for ITER design analysis. Correlations are developed to describe the performance of beryllium in a fusion reactor environment. While this paper focuses on the use of beryllium as a plasma-facing component (PFC) material, the correlations presented here can also be used to describe the performance of beryllium as a neutron multiplier for a tritium breeding blanket. The performance properties for beryllium are subdivided into two categories: properties which do not change with irradiation damage to the bulk of the material; and properties which are degraded by neutron irradiation. The irradiation-independent properties described within are: thermal conductivity, specific heat capacity, thermal expansion, and elastic constants. Irradiation-dependent properties include: yield strength, ultimate tensile strength, plastic tangent modulus, uniform and total tensile elongation, thermal and irradiation-induced creep strength, He-induced swelling and tritium retention/release. The approach taken in developing properties correlations is to describe the behavior of dense, pressed S-65 beryllium -- the material chosen for ITER PFC application -- as a function of temperature. As there are essentially no data on the performance of porous and/or irradiated S-65 beryllium, the degradation of properties with as-fabricated porosity and irradiation are determined from the broad data base on S-200F, as well as other types and grades, and applied to S-65 beryllium by scaling factors. The resulting correlations can be used for Be produced by vacuum hot pressing (VHP) and cold-pressing (CP)/sintering(S)/hot-isostatic-pressing (HIP). The performance of plasma-sprayed beryllium is discussed but not quantified.

  7. Fluorimetric method for determination of Beryllium

    International Nuclear Information System (INIS)

    The old fluorimetric method for the determination of Beryllium, based essentially on the fluorescence of the Beryllium-Morine complex in a strongly alkaline solution, is still competitive and stands the comparison with more modern methods or at least three reasons: in the presence of solid or gaseous samples (powders), the times necessary to finalize an analytic determination are comparable since the stage of the process which lasts the longest is the mineralization of the solid particles containing Beryllium, the cost of a good fluorimeter is by far Inferior to the cost, e. g., of an Emission Spectrophotometer provided with ICP torch and magnets for exploiting the Zeeman effect and of an Atomic absorption Spectrophotometer provided with Graphite furnace; it is possible to determine, fluorimetrically, rather small Beryllium levels (about 30 ng of Beryllium/sample), this potentiality is more than sufficient to guarantee the respect of all the work safety and hygiene rules now in force. The study which is the subject of this publication is designed to the analysis procedure which allows one to reach good results in the determination of Beryllium, chiefly through the control and measurement of the interference effect due to the presence of some metals which might accompany the environmental samples of workshops and laboratories where Beryllium is handled, either at the pure state or in its alloys. The results obtained satisfactorily point out the merits and limits of this analytic procedure

  8. Chronic Beryllium Disease Prevention Program Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S

    2012-03-29

    This document describes how Lawrence Livermore National Laboratory (LLNL) meets the requirements and management practices of federal regulation 10 CFR 850, 'Chronic Beryllium Disease Prevention Program (CBDPP).' This revision of the LLNL CBDPP incorporates clarification and editorial changes based on lessons learned from employee discussions, observations and reviews of Department of Energy (DOE) Complex and commercial industry beryllium (Be) safety programs. The information is used to strengthen beryllium safety practices at LLNL, particularly in the areas of: (1) Management of small parts and components; and (2) Communication of program status to employees. Future changes to LLNL beryllium activities and on-going operating experience will be incorporated into the program as described in Section S, 'Performance Feedback.'

  9. Safety handling of beryllium for fusion technology R and D

    International Nuclear Information System (INIS)

    Feasibility of beryllium use as a blanket neutron multiplier, first wall and plasma facing material has been studied for the D-T burning experiment reactors such as ITER. Various experimental work of beryllium and its compounds will be performed under the conditions of high temperature and high energy particle exposure simulating fusion reactor conditions. Beryllium is known as a hazardous substance and its handling has been carefully controlled by various health and safe guidances and/or regulations in many countries. Japanese regulations for hazardous substance provide various guidelines on beryllium for the protection of industrial workers and environment. This report was prepared for the safe handling of beryllium in a laboratory scale experiments for fusion technology R and D such as blanket development. Major items in this report are; (1) Brief review of guidances and regulations in USA, UK and Japan. (2) Safe handling and administration manuals at beryllium facilities in INEL, LANL and JET. (3) Conceptual design study of beryllium handling facility for small to mid-scale blanket R and D. (4) Data on beryllium toxicity, example of clinical diagnosis of beryllium disease, and environmental occurence of beryllium. (5) Personnel protection tools of Japanese Industrial Standard for hazardous substance. (author) 61 refs

  10. Study on neutron irradiation behavior of beryllium as neutron multiplier

    Energy Technology Data Exchange (ETDEWEB)

    Ishitsuka, Etsuo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    1998-03-01

    More than 300 tons beryllium is expected to be used as a neutron multiplier in ITER, and study on the neutron irradiation behavior of beryllium as the neutron multiplier with Japan Materials Testing Reactor (JMTR) were performed to get the engineering data for fusion blanket design. This study started as the study on the tritium behavior in beryllium neutron reflector in order to make clear the generation mechanism on tritium of JMTR primary coolant since 1985. These experiences were handed over to beryllium studies for fusion study, and overall studies such as production technology of beryllium pebbles, irradiation behavior evaluation and reprocessing technology have been started since 1990. In this presentation, study on the neutron irradiation behavior of beryllium as the neutron multiplier with JMTR was reviewed from the point of tritium release, thermal properties, mechanical properties and reprocessing technology. (author)

  11. Tritium release from neutron irradiated beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Scaffidi-Argentina, F.; Werle, H. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Neutronenphysik und Reactortechnik

    1998-01-01

    One of the most important open issues related to beryllium for fusion applications refers to the kinetics of the tritium release as a function of neutron fluence and temperature. The EXOTIC-7 as well as the `Beryllium` experiments carried out in the HFR reactor in Petten are considered as the most detailed and significant tests for investigating the beryllium response under neutron irradiation. This paper reviews the present status of beryllium post-irradiation examinations performed at the Forschungszentrum Karlsruhe with samples from the above mentioned irradiation experiments, trying to elucidate the tritium release controlling processes. In agreement with previous studies it has been found that release starts at about 500-550degC and achieves a maximum at about 700-750degC. The observed release at about 500-550degC is probably due to tritium escaping from chemical traps, while the maximum release at about 700-750degC is due to tritium escaping from physical traps. The consequences of a direct contact between beryllium and ceramics during irradiation, causing tritium implanting in a surface layer of beryllium up to a depth of about 40 mm and leading to an additional inventory which is usually several times larger than the neutron-produced one, are also presented and the effects on the tritium release are discussed. (author)

  12. Measurement of the production cross-section of positive pions in the collision of 8.9 GeV/c protons on beryllium

    CERN Document Server

    Catanesi, M G; Apollonio, M; Arce, P; Artamonov, A; Bagulya, A; Barr, G; Blondel, A; Bobisut, F; Bogomilov, M; Bonesini, M; Booth, C; Borghi, S; Bunyatov, S; Burguet-Castell, J; Buttar, C; Campanelli, M; Cervera-Villanueva, A; Chelkov, G A; Chernyaev, E; Chimenti, P; Chizhov, M; Coney, L; De Min, A; De Santo, A; Dedovitch, D; Di Capua, E; Dore, U; Dumarchez, J; Edgecock, R; Ellis, M; Engel, R; Ferri, F; Gastaldi, Ugo; Giani, S; Giannini, G; Gibin, D; Gilardoni, S; Gome-Cadenas, J J; Gorbunov, P; Gostkin, M I; Grant, A; Graulich, J S; Grichine, V; Grossheim, A; Gruber, P; Grégoire, G; Guglielmi, A M; Guskov, A; Gössling, C; Hodgson, P; Howlett, L; Ivanchenko, V; Kato, I; Kayis-Topaksu, A; Khartchenko, D; Kirsanov, M; Kolev, D; Koreshev, V; Krasnoperov, A V; Krumshtein, Z; Martín-Albo, J; Meurer, C; Mezzetto, M; Mills, G B; Morone, M C; Nefedov, Y; Novella, P; Orestano, D; Paganoni, M; Paleari, F; Palladino, V; Panman, J; Papadopoulos, I; Pasternak, J; Pastore, F; Pattison, C; Piperov, S; Polukhina, N; Popov, B; Prior, G; Radicioni, E; Robbins, S; Santin, G; Schmitz, D; Schroeter, R; Semak, A; Serdiouk, V; Soler, F J P; Sorel, M; Temnikov, P; Tereshchenko, V V; Tonazzo, A; Tornero, A; Tortora, L; Tsenov, R; Tsukerman, I; Vannucci, F; Veenhof, R; Vidal-Sitjes, G; Wiebusch, C; Zaets, V; Zhemchugov, A; Zuber, K; Zucchelli, P

    2007-01-01

    The double-differential production cross-section of positive pions, $d^2\\sigma^{\\pi^{+}}/dpd\\Omega$, measured in the HARP experiment is presented. The incident particles are 8.9 \\GeVc protons directed onto a beryllium target with a nominal thickness of 5% of a nuclear interaction length. The measured cross-section has a direct impact on the prediction of neutrino fluxes for the MiniBooNE and SciBooNE experiments at Fermilab. After cuts, 13 million protons on target produced about 96,000 reconstructable secondary tracks which were used in this analysis. Cross-section results are presented in the kinematic range 0.75~${GeV}/c$ $\\leq p_{\\pi} \\leq$ 6.5 ${GeV}/c$ and 30 mrad $\\leq \\theta_{\\pi} \\leq$ 210 mrad in the laboratory frame.

  13. Measurement of the production cross-section of positive pions in the collision of 8.9 GeV/c protons on beryllium

    Science.gov (United States)

    Catanesi, M. G.; HARP Collaboration; Radicioni, E.; Edgecock, R.; Ellis, M.; Robbins, S.; Soler, F. J. P.; Gößling, C.; Bunyatov, S.; Chelkov, G.; Dedovitch, D.; Gostkin, M.; Guskov, A.; Khartchenko, D.; Krasnoperov, A.; Kroumchtein, Z.; Nefedov, Y.; Popov, B.; Serdiouk, V.; Tereshchenko, V.; Zhemchugov, A.; di Capua, E.; Vidal-Sitjes, G.; Artamonov, A.; Arce, P.; Giani, S.; Gilardoni, S.; Gorbunov, P.; Grant, A.; Grossheim, A.; Gruber, P.; Ivanchenko, V.; Kayis-Topaksu, A.; Panman, J.; Papadopoulos, I.; Pasternak, J.; Tcherniaev, E.; Tsukerman, I.; Veenhof, R.; Wiebusch, C.; Zucchelli, P.; Blondel, A.; Borghi, S.; Campanelli, M.; Morone, M. C.; Prior, G.; Schroeter, R.; Engel, R.; Meurer, C.; Kato, I.; Gastaldi, U.; Mills, G. B.; Graulich, J. S.; Grégoire, G.; Bonesini, M.; de Min, A.; Ferri, F.; Paganoni, M.; Paleari, F.; Kirsanov, M.; Bagulya, A.; Grichine, V.; Polukhina, N.; Palladino, V.; Coney, L.; Schmitz, D.; Barr, G.; de Santo, A.; Pattison, C.; Zuber, K.; Bobisut, F.; Gibin, D.; Guglielmi, A.; Mezzetto, M.; Dumarchez, J.; Vannucci, F.; Ammosov, V.; Koreshev, V.; Semak, A.; Zaets, V.; Dore, U.; Orestano, D.; Pastore, F.; Tonazzo, A.; Tortora, L.; Booth, C.; Buttar, C.; Hodgson, P.; Howlett, L.; Bogomilov, M.; Chizhov, M.; Kolev, D.; Tsenov, R.; Piperov, S.; Temnikov, P.; Apollonio, M.; Chimenti, P.; Giannini, G.; Santin, G.; Burguet-Castell, J.; Cervera-Villanueva, A.; Gómez-Cadenas, J. J.; Martín-Albo, J.; Novella, P.; Sorel, M.; Tornero, A.

    2007-09-01

    The double-differential production cross-section of positive pions, d^2σ^{π+}/d pdΩ, measured in the HARP experiment is presented. The incident particles are 8.9 GeV/c protons directed onto a beryllium target with a thickness of 5% of a nuclear interaction length. The measured cross-section has a direct impact on the prediction of neutrino fluxes for the MiniBooNE and SciBooNE experiments at Fermilab. After cuts, 13 million protons on target produced about 96000 reconstructed secondary tracks which were used in this analysis. Cross-section results are presented in the kinematic range 0.75 GeV/c≤pπ≤ 6.5 GeV/c and 30 mrad≤θπ≤ 210 mrad in the laboratory frame.

  14. Beryllium Manufacturing Processes

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, A

    2006-06-30

    This report is one of a number of reports that will be combined into a handbook on beryllium. Each report covers a specific topic. To-date, the following reports have been published: (1) Consolidation and Grades of Beryllium; (2) Mechanical Properties of Beryllium and the Factors Affecting these Properties; (3) Corrosion and Corrosion Protection of Beryllium; (4) Joining of Beryllium; (5) Atomic, Crystal, Elastic, Thermal, Nuclear, and other Properties of Beryllium; and (6) Beryllium Coating (Deposition) Processes and the Influence of Processing Parameters on Properties and Microstructure. The conventional method of using ingot-cast material is unsuitable for manufacturing a beryllium product. Beryllium is a highly reactive metal with a high melting point, making it susceptible to react with mold-wall materials forming beryllium compounds (BeO, etc.) that become entrapped in the solidified metal. In addition, the grain size is excessively large, being 50 to 100 {micro}m in diameter, while grain sizes of 15 {micro}m or less are required to meet acceptable strength and ductility requirements. Attempts at refining the as-cast-grain size have been unsuccessful. Because of the large grain size and limited slip systems, the casting will invariably crack during a hot-working step, which is an important step in the microstructural-refining process. The high reactivity of beryllium together with its high viscosity (even with substantial superheat) also makes it an unsuitable candidate for precision casting. In order to overcome these problems, alternative methods have been developed for the manufacturing of beryllium. The vast majority of these methods involve the use of beryllium powders. The powders are consolidated under pressure in vacuum at an elevated temperature to produce vacuum hot-pressed (VHP) blocks and vacuum hot-isostatic-pressed (HIP) forms and billets. The blocks (typically cylindrical), which are produced over a wide range of sizes (up to 183 cm dia. by 61

  15. Beryllium-10 in Australasian tektites - Evidence for a sedimentary precursor

    Science.gov (United States)

    Pal, D. K.; Moniot, R. K.; Kruse, T. H.; Herzog, G. F.; Tuniz, C.

    1982-01-01

    Each of seven Australasian tektites contains about 100 micron atoms of beryllium-10 (half-life, 1.53 million years) per gram. Cosmic-ray bombardment of the australites cannot have produced the measured amounts of beryllium-10 either at the earth's surface or in space. The beryllium-10 contents of these australites are consistent with a sedimentary precursor that adsorbed from precipitation beryllium-10 produced in the atmosphere. The sediments must have spent several thousand years at the earth's surface within a few million years of the tektite-producing event.

  16. Measurement of the tensor analyzing power in the inelastic scattering of deuteron on beryllium at an angle of 80 mrad at 4.5 GeV/c

    International Nuclear Information System (INIS)

    Tensor Ayy and vector Ayy analyzing powers of inelastic scattering of deuterons with momentum of 4.5 GeV/c on beryllium at and angle of ∼ 80 mrad in the vicinity of baryonic resonance excitation have been measured. The new Ayy data being plotted versus t are in good agreement with the previous data at 4/5, 5.5, and 9 GeV/c, obtained at zero angle in an overlapping region of t, and all existing data fit the common |t| dependence up to ∼ 0.9 (GeV/c)2. The results of the experiment are compared with the calculations in the framework of the multiple-scattering and ω-meson exchange models in t-channel

  17. Postirradiation examination of beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Gelles, D.S. [Pacific Northwest National Lab., Richland, WA (United States)

    1998-03-01

    Postirradiation examinations of COBRA-1A beryllium pebbles irradiated in the EBR-II fast reactor at neutron fluences which generated 2700--3700 appm helium have been performed. Measurements included density change, optical microscopy, scanning electron microscopy, and transmission electron microscopy. The major change in microstructure is development of unusually shaped helium bubbles forming as highly non-equiaxed thin platelet-like cavities on the basal plane. Measurement of the swelling due to cavity formation was in good agreement with density change measurements.

  18. Protection of air in premises and environment against beryllium aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Bitkolov, N.Z.; Vishnevsky, E.P.; Krupkin, A.V. [Research Inst. of Industrial and Marine Medicine, St. Petersburg (Russian Federation)

    1998-01-01

    First and foremost, the danger of beryllium aerosols concerns a possibility of their inhalation. The situation is aggravated with high biological activity of the beryllium in a human lung. The small allowable beryllium aerosols` concentration in air poses a rather complex and expensive problem of the pollution prevention and clearing up of air. The delivery and transportation of beryllium aerosols from sites of their formation are defined by the circuit of ventilation, that forms aerodynamics of air flows in premises, and aerodynamic links between premises. The causes of aerosols release in air of premises from hoods, isolated and hermetically sealed vessels can be vibrations, as well as pulses of temperature and pressure. Furthermore, it is possible the redispersion of aerosols from dirty surfaces. The effective protection of air against beryllium aerosols at industrial plants is provided by a complex of hygienic measures: from individual means of breath protection up to collective means of the prevention of air pollution. (J.P.N.)

  19. Development of Beryllium Vacuum Chamber Technology for the LHC

    CERN Document Server

    Veness, R; Dorn, C

    2011-01-01

    Beryllium is the material of choice for the beam vacuum chambers around collision points in particle colliders due to a combination of transparency to particles, high specific stiffness and compatibility with ultra-high vacuum. New requirements for these chambers in the LHC experiments have driven the development of new methods for the manufacture of beryllium chambers. This paper reviews the requirements for experimental vacuum chambers. It describes the new beryllium technology adopted for the LHC and experience gained in the manufacture and installation.

  20. Status of beryllium development for fusion applications

    International Nuclear Information System (INIS)

    Beryllium is a leading candidate material for the neutron multiplier of tritium breeding blankets and the plasma-facing component of first-wall and divertor systems. Depending on the application, the fabrication methods proposed include hot-pressing, hot-isostatic-pressing, cold-isostatic-pressing/sintering, rotary electrode processing and plasma spraying. Product forms include blocks, tubes, pebbles, tiles and coatings. While, in general, beryllium is not a leading structural material candidate, its mechanical performance, as well as its performance with regard to sputtering, heat transport, tritium retention/release, helium-induced swelling and chemical compatibility, is an important consideration in first-wall/blanket design. Differential expansion within the beryllium causes internal stresses which may result in cracking, thereby affecting the heat transport and barrier performance of the material. Overall deformation can result in loading of neighboring structural material. Thus, in assessing the performance of beryllium for fusion applications, it is important to have a good database in all of these performance areas, as well as a set of properties correlations and models for the purpose of interpolation/extrapolation.In this current work, the range of anticipated fusion operating conditions is reviewed. The thermal, mechanical, chemical compatibility, tritium retention/release, and helium retention/swelling databases are then reviewed for fabrication methods and fusion operating conditions of interest. Properties correlations and uncertainty ranges are also discussed. In the case of the more complex phenomena of tritium retention/release and helium-induced swelling, fundamental mechanisms and models are reviewed in more detail. Areas in which additional data are needed are highlighted, along with some trends which suggest ways of optimizing the performance of beryllium for fusion applications. (orig.)

  1. An analysis of seasonal changes in STE using measurements from the TOPSE campaign and the Beryllium-7 distribution from a calculation driven by the GEOS-3 DAS.

    Science.gov (United States)

    Allen, D. J.; Dibb, J. E.; Ridley, B.; Pickering, K. E.

    2002-05-01

    Measurements of tropospheric ozone (O3) between 30\\deg and 70\\deg N show springtime maxima at remote locations. The contribution of seasonal changes in stratosphere-troposphere exchange (STE) to these maxima was investigated using measurements from the Tropospheric Ozone Production about the Spring Equinox Experiment (TOPSE) campaign and the Beryllium-7 (7Be) distribution from a calculation driven by fields from the Goddard Earth Observing System Data Assimilation System. Comparison with TOPSE measurements revealed that upper tropospheric model-calculated 7Be mixing ratios were reasonable (a change from previous calculations) but that lower tropospheric mixing ratios were too low most likely due to an overestimation of scavenging. Temporal fluctuations were well captured although their amplitudes were often underestimated. Analysis of O3 measurements indicated that mixing ratios increased by 5-10% per month for θ underworld) and by 10-15% per month for θ > 300 K (the tropospheric middleworld). 7Be mixing ratios decreased with time for θ 300 K. Model-calculated middleworld increases of 7Be were a factor of 2 less than measured increases. 7Be with a stratospheric source (strat-7Be) increased by 4.6-8.8% along TOPSE flight paths within the tropospheric middleworld. Increases in strat-7Be were not seen along TOPSE flight paths in the underworld. Assuming changes in O3 with a stratospheric source are the same as changes in strat-7Be and that 50% of O3 is produced in the stratosphere, changes in STE explain 20-60% of O3 increases in the tropospheric middleworld and less than 30% of O3 increases in the underworld.

  2. On-Line Measurements of Beryllium, Chromium, and Mercury by Using Aerosol Beam Focused Laser-Induced Plasma Spectrometer and Time-Integrated Filter Sampling Reference Method

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, M.D.

    2003-05-15

    A novel real-time monitor for aerosol particles has been developed by the Oak Ridge National Laboratory (ORNL). The instrument is designed to perform in-situ measurement for the elemental composition of aerosol particles in flue gas. We had tested this monitor at the Eastman Chemical Company in July 2001 taking advantage of the emissions from a waste incinerator operated by the company as the background. To investigate the behavior and response of the monitor under simulated/known conditions, stock solutions of prepared metal concentration(s) were nebulized to provide spikes for the instrument testing. Strengths of the solutions were designed such that a reference method (RM) was able to collect sufficient material on filter samples that were subsequently analyzed in a laboratory to produce 30-minute average data points. Parallel aerosol measurements were performed by using the ORNL instrument. Recorded signal of an individual element was processed and the concentration calculated from a calibration curve established prior to the campaign. RM data were able to reflect the loads simulated in the spiked waste stream. However, it missed one beryllium sample. The possibility of bias exists in the RM determination of chromium that could lead to erroneous comparison between the RM and the real-time monitoring data. With the real-time detection capability, the ORNL instrument was able to reveal the emission variation by making seven measurements within a 30-minute cycle. The ability of the instrument also enables the reconstruction of the baseline chromium emission concentration. The measurements for mercury by both methods are in good agreement.

  3. On-Line Measurement of Beryllium, Chromium, and Mercury by Using Aerosol Beam Focused Laser-Induced Plasma Spectrometer and TIme-Integrated Filter Sampling and Reference Method

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, M.-D.; Vannice, R.W.

    2003-05-20

    A novel real-time monitor for aerosol particles has been developed by the Oak Ridge National Laboratory (ORNL). The instrument is designed to perform in-situ measurement for the elemental composition of aerosol particles in flue gas. They had tested this monitor at the Eastman Chemical Company in July 2001 taking advantage of the emissions from a waste incinerator operated by the company as the background. To investigate the behavior and response of the monitor under simulated/known conditions, stock solutions of prepared metal concentration(s) were nebulized to provide spikes for the instrument testing. Strengths of the solutions were designed such that a reference method (RM) was able to collect sufficient material on filter samples that were analyzed in a laboratory to produce 30-minute average data points. Parallel aerosol measurements were performed by using the ORNL instrument. Recorded signal of an individual element was processed and the concentration calculated from a calibration curve established prior to the campaign. RM data were able to reflect the loads simulated in the spiked waste stream. However, it missed one beryllium sample. The possibility of bias exists in the RM determination of chromium that could lead to erroneous comparison between the RM and the real-time monitoring data. With the real-time detection capability, the ORNL instrument was able to reveal the emission variation by making seven measurements within a 30-minute cycle. The ability of the instrument also enables the reconstruction of the baseline chromium emission concentration. The measurements for mercury by both methods are in good agreement.

  4. Reprocessing technology development for irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, H.; Sakamoto, N. [Oarai Research Establishment, Ibaraki-ken (Japan); Tatenuma, K. [KAKEN Co., Ibaraki-ken (Japan)] [and others

    1995-09-01

    At present, beryllium is under consideration as a main candidate material for neutron multiplier and plasma facing material in a fusion reactor. Therefore, it is necessary to develop the beryllium reprocessing technology for effective resource use. And, we have proposed reprocessing technology development on irradiated beryllium used in a fusion reactor. The preliminary reprocessing tests were performed using un-irradiated and irradiated beryllium. At first, we performed beryllium separation tests using un-irradiated beryllium specimens. Un-irradiated beryllium with beryllium oxide which is a main impurity and some other impurities were heat-treated under chlorine gas flow diluted with Ar gas. As the results high purity beryllium chloride was obtained in high yield. And it appeared that beryllium oxide and some other impurities were removed as the unreactive matter, and the other chloride impurities were separated by the difference of sublimation temperature on beryllium chloride. Next, we performed some kinds of beryllium purification tests from beryllium chloride. And, metallic beryllium could be recovered from beryllium chloride by the reduction with dry process. In addition, as the results of separation and purification tests using irradiated beryllium specimens, it appeared that separation efficiency of Co-60 from beryllium was above 96%. It is considered that about 4% Co-60 was carried from irradiated beryllium specimen in the form of cobalt chloride. And removal efficiency of tritium from irradiated beryllium was above 95%.

  5. Aerosols generated during beryllium machining.

    Science.gov (United States)

    Martyny, J W; Hoover, M D; Mroz, M M; Ellis, K; Maier, L A; Sheff, K L; Newman, L S

    2000-01-01

    Some beryllium processes, especially machining, are associated with an increased risk of beryllium sensitization and disease. Little is known about exposure characteristics contributing to risk, such as particle size. This study examined the characteristics of beryllium machining exposures under actual working conditions. Stationary samples, using eight-stage Lovelace Multijet Cascade Impactors, were taken at the process point of operation and at the closest point that the worker would routinely approach. Paired samples were collected at the operator's breathing zone by using a Marple Personal Cascade Impactor and a 35-mm closed-faced cassette. More than 50% of the beryllium machining particles in the breathing zone were less than 10 microns in aerodynamic diameter. This small particle size may result in beryllium deposition into the deepest portion of the lung and may explain elevated rates of sensitization among beryllium machinists.

  6. Beryllium. Its minerals. Pt. 1

    International Nuclear Information System (INIS)

    With this work a series of reports begins, under the generic name 'Beryllium', related to several aspects of beryllium technology. The target is to update, with critical sense, current bibliographic material in order to be used in further applications. Some of the most important beryllium ores, the Argentine emplacement of their deposits and world occurrence are described. Argentine and world production, resources and reserves are indicated here as well. (Author)

  7. Spray measurement technology: a review

    International Nuclear Information System (INIS)

    Sprays are among the most intellectually challenging and practically important topics in fluid mechanics. This paper reviews needs, milestones, challenges, and a broad array of techniques for spray measurement. In addition, tabular summaries provide cross-referenced entry points to the vast literature by organizing over 300 citations according to key spray phenomena, physical parameters and measurement techniques for each of the principal spray regions (nozzle internal flow, near-field spray-formation region, far-field developed spray, and spray-wall interaction). The article closes with perspectives on some current issues in spray research, including the cost and complexity of apparatus for spray physics and spray engineering, the need for simultaneous diagnostic measurements under application-relevant conditions, and the effective comparison of spray measurements and numerical simulations. (topical review)

  8. Fluorimetric method for determination of Beryllium; Determinazione fluorimetrica del berillio

    Energy Technology Data Exchange (ETDEWEB)

    Sparacino, N.; Sabbioneda, S. [ENEA, Centro Ricerche Saluggia, Vercelli (Italy). Dip. Energia

    1996-10-01

    The old fluorimetric method for the determination of Beryllium, based essentially on the fluorescence of the Beryllium-Morine complex in a strongly alkaline solution, is still competitive and stands the comparison with more modern methods or at least three reasons: in the presence of solid or gaseous samples (powders), the times necessary to finalize an analytic determination are comparable since the stage of the process which lasts the longest is the mineralization of the solid particles containing Beryllium, the cost of a good fluorimeter is by far Inferior to the cost, e. g., of an Emission Spectrophotometer provided with ICP torch and magnets for exploiting the Zeeman effect and of an Atomic absorption Spectrophotometer provided with Graphite furnace; it is possible to determine, fluorimetrically, rather small Beryllium levels (about 30 ng of Beryllium/sample), this potentiality is more than sufficient to guarantee the respect of all the work safety and hygiene rules now in force. The study which is the subject of this publication is designed to the analysis procedure which allows one to reach good results in the determination of Beryllium, chiefly through the control and measurement of the interference effect due to the presence of some metals which might accompany the environmental samples of workshops and laboratories where Beryllium is handled, either at the pure state or in its alloys. The results obtained satisfactorily point out the merits and limits of this analytic procedure.

  9. Joining of Beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, A

    2006-02-01

    A handbook dealing with the many aspects of beryllium that would be important for the users of this metal is currently being prepared. With an introduction on the applications, advantages and limitations in the use of this metal the following topics will be discussed in this handbook: physical, thermal, and nuclear properties; extraction from the ores; purification and casting of ingots; production and types of beryllium powders; consolidation methods, grades, and properties; mechanical properties with emphasis on the various factors affecting these properties; forming and mechanical working; welding, brazing, bonding, and fastening; machining; powder deposition; corrosion; health aspects; and examples of production of components. This report consists of ''Section X--Joining'' from the handbook. The prefix X is maintained here for the figures, tables and references. In this section the different methods used for joining beryllium and the advantages, disadvantages and limitations of each are presented. The methods discussed are fusion welding, brazing, solid state bonding (diffusion bonding and deformation bonding), soldering, and mechanical fastening. Since beryllium has a high affinity for oxygen and nitrogen with the formation of oxides and nitrides, considerable care must be taken on heating the metal, to protect it from the ambient atmosphere. In addition, mating surfaces must be cleaned and joints must be designed to minimize residual stresses as well as locations for stress concentration (notch effects). In joining any two metals the danger exists of having galvanic corrosion if the part is subjected to moisture or to any type of corroding environment. This becomes a problem if the less noble (anodic) metal has a significantly smaller area than the more noble (cathodic) metal since the ions (positive charges) from the anodic (corroding) metal must correspond to the number of electrons (negative charges) involved at the cathode. Beryllium

  10. Fallout beryllium-7 as a soil and sediment tracer in river basins: current status and needs

    Science.gov (United States)

    Taylor, Alex; Blake, Will H.; Smith, Hugh G.; Mabit, Lionel; Keith-Roach, Miranda J.

    2013-04-01

    Beryllium-7 is a cosmogenic radionuclide formed in the upper atmosphere by cosmic ray spallation of nitrogen and oxygen. Its constant natural production and fallout via precipitation coupled with its ability to bind to soil particles have underpinned its application as a sediment tracer. The short half-life of beryllium-7 (53.3 days) lends itself to tracing sediment dynamics over short time periods, thus, enabling assessment of the effect of land use change upon soil redistribution. Although beryllium-7 has been widely applied as a tracer to date, there remain crucial gaps in understanding relating to the assumptions for its use. To further support the application of beryllium-7 as a tracer across a range of environments requires consideration of both the current strengths and shortcomings of the technique to direct research needs. Here we review research surrounding the assumptions underpinning beryllium-7 use as a tracer and identify key knowledge gaps relating to i) the effects of rain shadowing and vegetation interception upon beryllium-7 fallout uniformity at the hillslope-scale; ii) the effect of preferential flow pathways upon beryllium-7 depth distribution in soil and overland flow upon beryllium-7 inventory uniformity and iii) the potential for beryllium-7 desorption in saline and reducing environments. To provide continued support for the use of beryllium-7 as a hillslope and catchment-scale tracer, there is an urgent need to undertake further research to quantify the effect of these factors upon tracer estimates.

  11. Technical Basis for PNNL Beryllium Inventory

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Michelle Lynn

    2014-07-09

    The Department of Energy (DOE) issued Title 10 of the Code of Federal Regulations Part 850, “Chronic Beryllium Disease Prevention Program” (the Beryllium Rule) in 1999 and required full compliance by no later than January 7, 2002. The Beryllium Rule requires the development of a baseline beryllium inventory of the locations of beryllium operations and other locations of potential beryllium contamination at DOE facilities. The baseline beryllium inventory is also required to identify workers exposed or potentially exposed to beryllium at those locations. Prior to DOE issuing 10 CFR 850, Pacific Northwest Nuclear Laboratory (PNNL) had documented the beryllium characterization and worker exposure potential for multiple facilities in compliance with DOE’s 1997 Notice 440.1, “Interim Chronic Beryllium Disease.” After DOE’s issuance of 10 CFR 850, PNNL developed an implementation plan to be compliant by 2002. In 2014, an internal self-assessment (ITS #E-00748) of PNNL’s Chronic Beryllium Disease Prevention Program (CBDPP) identified several deficiencies. One deficiency is that the technical basis for establishing the baseline beryllium inventory when the Beryllium Rule was implemented was either not documented or not retrievable. In addition, the beryllium inventory itself had not been adequately documented and maintained since PNNL established its own CBDPP, separate from Hanford Site’s program. This document reconstructs PNNL’s baseline beryllium inventory as it would have existed when it achieved compliance with the Beryllium Rule in 2001 and provides the technical basis for the baseline beryllium inventory.

  12. The beryllium quandary: will the lower exposure limits spur new developments in sampling and analysis?

    Energy Technology Data Exchange (ETDEWEB)

    Brisson, Michael

    2013-06-03

    At the time this article was written, new rulemakings were under consideration at OSHA and the U.S. Department of Energy (DOE) that would propose changes to occupational exposure limits for beryllium. Given these developments, it’s a good time to review the tools and methods available to IHs for assessing beryllium air and surface contamination in the workplace—what’s new and different, and what’s tried and true. The article discusses limit values and action levels for beryllium, problematic aspects of beryllium air sampling, sample preparation, sample analysis, and data evaluation.

  13. Experiments on studying beryllium - steam interaction, determination of oxidated beryllium emissivity factor

    International Nuclear Information System (INIS)

    The report presents results of beryllium emissivity factor measurements within 700-1300 K temperature range. The tests were conducted at Institute of Atomic Energy of the National Nuclear Center of the Republic of Kazakhstan to receive experimental data for verification of calculation programs describing an accident involving water coolant discharge into ITER reactor vacuum cavity. (author)

  14. Neutron counter based on beryllium activation

    Energy Technology Data Exchange (ETDEWEB)

    Bienkowska, B.; Prokopowicz, R.; Kaczmarczyk, J.; Paducha, M. [Institute of Plasma Physics and Laser Microfusion (IPPLM), Hery 23, 01-497 Warsaw (Poland); Scholz, M.; Igielski, A. [Institute of Nuclear Physics PAS (IFJPAN), Radzikowskiego 152, 31-342 Krakow (Poland); Karpinski, L. [Faculty of Electrical Engineering, Rzeszow University of Technology, Pola 2, 35-959 Rzeszow (Poland); Pytel, K. [National Centre for Nuclear Research (NCBJ), Soltana 7, 05-400 Otwock - Swierk (Poland)

    2014-08-21

    The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction {sup 9}Be(n, α){sup 6}He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, {sup 6}He, decays with half-life T{sub 1/2} = 0.807 s emitting β{sup −} particles which are easy to detect. Large area gas sealed proportional detector has been chosen as a counter of β–particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β–source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5–the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β{sup −} particles emitted from radioactive {sup 6}He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.

  15. Neutron counter based on beryllium activation

    Science.gov (United States)

    Bienkowska, B.; Prokopowicz, R.; Scholz, M.; Kaczmarczyk, J.; Igielski, A.; Karpinski, L.; Paducha, M.; Pytel, K.

    2014-08-01

    The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction 9Be(n, α)6He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, 6He, decays with half-life T1/2 = 0.807 s emitting β- particles which are easy to detect. Large area gas sealed proportional detector has been chosen as a counter of β-particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β-source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5-the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β- particles emitted from radioactive 6He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.

  16. Measurement of the Tensor $A_{yy}$ and Vector $A_y$ Analyzing Powers of the Deuteron Inelastic Scattering on Beryllium at 5.0 GeV/c and 178 mrad

    CERN Document Server

    Azhgirey, L S; Isupov, A Yu; Ivanov, V I; Khrenov, A N; Ladygin, V P; Ladygina, N B; Litvinenko, A G; Peresedov, V F; Yudin, N P; Zhmyrov, V N; Zolin, L S

    2004-01-01

    Tensor $A_{yy}$ and vector $A_{y}$ analyzing powers in the inelastic scattering of deuterons with a momentum of 5.0 GeV/c on beryllium at an angle of 178 mrad in the vicinity of the excitation of baryonic resonances with masses up to $\\sim$ 1.8 GeV/${\\rm c}^2$ have been measured. The $A_{yy}$ data are in good agreement with the previous data obtained at 4.5 and 5.5 GeV/c. The results of the experiment are compared with the predictions of the plane-wave impulse approximation and $\\omega$-meson exchange model.

  17. Review of neutrino mass measurements

    International Nuclear Information System (INIS)

    The current status of the experimental search for neutrino mass is reviewed, with emphasis on direct kinematic methods. New data on the /tau/ neutrino from the Argus collaboration have reduced the upper mass limit a factor of 2. The situation concerning the electron neutrino mass as measured in tritium beta decay is essentially unchanged from a year ago. Simpson and Hime report finding evidence for a 17-keV neutrino in the β decay of 35S. There may be evidence for neutrino mass and mixing in the SN1987a data. 62 refs., 4 figs

  18. Determination of beryllium by using X-ray fluorescence spectrometry.

    Science.gov (United States)

    Zawisza, Beata

    2008-03-01

    X-ray fluorescence spectrometry method is subject to certain difficulties and inconveniences for the elements having the atomic number 9 or less. These difficulties become progressively more severe as the atomic number decreases, and are quite serious for beryllium, which is practically indeterminable directly by XRF. Therefore, an indirect determination of beryllium that is based on the evaluation of cobalt in the precipitate is taken into consideration. In the thesis below, there is a description of a new, simple, and precise method by selective precipitation using hexamminecobalt(III) chloride and ammonium carbonate-EDTA solution as a complexing agent for the determining of a trace amount of beryllium using X-ray fluorescence spectrometry. The optimum conditions for [Co(NH(3))(6)][Be(2)(OH)(3)(CO(3))(2)(H(2)O)(2)].(3)H(2)O complex formation were studied. The complex was collected on the membrane filter, and the Co Kalpha line was measured by XRF. The method presents the advantages of the sample preparation and the elimination of the matrix effects due to the thin film obtained. The detection limit of the proposed method is 0.2 mg of beryllium. The method was successfully applied to beryllium determination in copper/ beryllium/cobalt alloys.

  19. Impurities effect on the swelling of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Donne, M.D.; Scaffidi-Argentina, F. [Institut fuer Neutronenphysik und Reaktortechnik, Karlsruhe (Germany)

    1995-09-01

    An important factor controlling the swelling behaviour of fast neutron irradiated beryllium is the impurity content which can strongly affect both the surface tension and the creep strength of this material. Being the volume swelling of the old beryllium (early sixties) systematically higher than that of the more modem one (end of the seventies), a sensitivity analysis with the aid of the computer code ANFIBE (ANalysis of Fusion Irradiated BEryllium) to investigate the effect of these material properties on the swelling behaviour of neutron irradiated beryllium has been performed. Two sets of experimental data have been selected: the first one named Western refers to quite recently produced Western beryllium, whilst the second one, named Russian refers to relatively old (early sixties) Russian beryllium containing a higher impurity rate than the Western one. The results obtained with the ANFIBE Code were assessed by comparison with experimental data and the used material properties were compared with the data available in the literature. Good agreement between calculated and measured values has been found.

  20. Plasma cleaning of beryllium coated mirrors

    Science.gov (United States)

    Moser, L.; Marot, L.; Steiner, R.; Newman, M.; Widdowson, A.; Ivanova, D.; Likonen, J.; Petersson, P.; Pintsuk, G.; Rubel, M.; Meyer, E.; Contributors, JET

    2016-02-01

    Cleaning systems of metallic first mirrors are needed in more than 20 optical diagnostic systems from ITER to avoid reflectivity losses. Currently, plasma sputtering is considered as one of the most promising techniques to remove deposits coming from the main wall (mainly beryllium and tungsten). This work presents the results of plasma cleaning of rhodium and molybdenum mirrors exposed in JET-ILW and contaminated with typical tokamak elements (including beryllium and tungsten). Using radio frequency (13.56 MHz) argon or helium plasma, the removal of mixed layers was demonstrated and mirror reflectivity improved towards initial values. The cleaning was evaluated by performing reflectivity measurements, scanning electron microscopy, x-ray photoelectron spectroscopy and ion beam analysis.

  1. Behavior of beryllium pebbles under irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dalle-Donne, M.; Scaffidi-Argentina, F. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Neutronenphysik und Reactortechnik; Baldwin, D.L.; Gelles, D.S.; Greenwood, L.R.; Kawamura, H.; Oliver, B.M.

    1998-01-01

    Beryllium pebbles are being considered in fusion reactor blanket designs as neutron multiplier. An example is the European `Helium Cooled Pebble Bed Blanket.` Several forms of beryllium pebbles are commercially available but little is known about these forms in response to fast neutron irradiation. Commercially available beryllium pebbles have been irradiated to approximately 1.3 x 10{sup 22} n/cm{sup 2} (E>1 MeV) at 390degC. Pebbles 1-mm in diameter manufactured by Brush Wellman, USA and by Nippon Gaishi Company, Japan, and 3-mm pebbles manufactured by Brush Wellman were included. All were irradiated in the below-core area of the Experimental Breeder Reactor-II in Idaho Falls, USA, in molybdenum alloy capsules containing helium. Post-irradiation results are presented on density change measurements, tritium release by assay, stepped-temperature anneal, and thermal ramp desorption tests, and helium release by assay and stepped-temperature anneal measurements, for Be pebbles from two manufacturing methods, and with two specimen diameters. The experimental results on density change and tritium and helium release are compared with the predictions of the code ANFIBE. (author)

  2. Evaluation of Cadmium Ratio and Foil Activation Measurements for a Beryllium-Reflected Assembly of U(93.15)O2 Fuel Rods (1.506-cm Triangular Pitch)

    International Nuclear Information System (INIS)

    A series of small, compact critical assembly (SCCA) experiments were completed from 1962 to 1965 at Oak Ridge National Laboratory's Critical Experiments Facility (ORCEF) in support of the Medium-Power Reactor Experiments (MPRE) program. Initial experiments, performed in November and December of 1962, consisted of a core of un-moderated stainless-steel tubes, each containing 26 UOIdaho National Laboratory (INL), Idaho Falls, ID (United States) fuel pellets, surrounded by a graphite reflector. Measurements were performed to determine critical reflector arrangements, fission-rate distributions, and cadmium ratio distributions. The graphite reflectors were then changed to beryllium reflectors. For the beryllium reflected assemblies, the fuel was in 1.506-cm-triangular and 7-tube clusters leading to two critical configurations. Once the critical configurations had been achieved, various measurements of reactivity, relative axial and radial activation rates of 235U, and cadmium ratios were performed. The cadmium ratio, reactivity, and activation rate measurements, performed on the 1.506-cm-array critical configuration, have been evaluated and are described in this paper

  3. Reduction evaporation of BeO to provide a beryllium metal sample for accelerator radiometric dating

    International Nuclear Information System (INIS)

    A technique is described for preparing beryllium metal samples from beryllium oxide for use in accelerator ion sources. These samples are used to measure minute 10Be/9Be ratios for radiometric dating at the University of Washington tandem Van de Graaff accelerator. (orig.)

  4. The uses and adverse effects of beryllium on health

    DEFF Research Database (Denmark)

    Cooper, Ross G.; Harrison, Adrian Paul

    2009-01-01

    in the current review for selecting articles were adopted from proposed criteria in The International Classification of Functioning, Disability, and Health. Articles were classified based on acute and chronic exposure and toxicity of beryllium. Results: The proportions of utilized and nonutilized articles were...

  5. Processing Irradiated Beryllium For Disposal

    Energy Technology Data Exchange (ETDEWEB)

    T. J. Tranter; R. D. Tillotson; N. R. Mann; G. R. Longhurst

    2005-11-01

    The purpose of this research was to develop a process for decontaminating irradiated beryllium that will allow it to be disposed of through normal radwaste channels. Thus, the primary objectives of this ongoing study are to remove the transuranic (TRU) isotopes to less than 100 nCi/g and remove {sup 60}Co, and {sup 137}Cs, to levels that will allow the beryllium to be contact handled. One possible approach that appears to have the most promise is aqueous dissolution and separation of the isotopes by selected solvent extraction followed by precipitation, resulting in a granular form for the beryllium that may be fixed to prevent it from becoming respirable and therefore hazardous. Beryllium metal was dissolved in nitric and fluorboric acids. Isotopes of {sup 241}Am, {sup 239}Pu, {sup 85}Sr, and {sup 137}Cs were then added to make a surrogate beryllium waste solution. A series of batch contacts was performed with the spiked simulant using chlorinated cobalt dicarbollide (CCD) and polyethylene glycol diluted with sulfone to extract the isotopes of Cs and Sr. Another series of batch contacts was performed using a combination of octyl (phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) in tributyl phosphate (TBP) diluted with dodecane for extracting the isotopes of Pu and Am. The results indicate that greater than 99.9% removal can be achieved for each isotope with only three contact stages.

  6. Status of beryllium materials for fusion application

    International Nuclear Information System (INIS)

    The possible use of beryllium as a material for fusion reactors is discussed. Based on the results of recent Russian elaborations, which were not covered previously in the scientific literature, an attempt of complex analysis of the techniques of using beryllium is made. The specific requirements on beryllium as a protective material for first wall and divertor are considered. Also the possibility of creating a fusion grade of beryllium is discussed and an optimum strategy is suggested. (orig.)

  7. Preliminary irradiation test for new material selection on lifetime extension of beryllium reflector

    International Nuclear Information System (INIS)

    Beryllium has been utilized as a moderator and/or reflector in Japan Materials Testing Reactor (JMTR), because of nuclear properties of beryllium, low neutron capture and high neutron scattering cross sections. At present, the amount of irradiated beryllium frames in JMTR is about 2 tons in the JMTR canal. In this study, preliminary irradiation test was performed from 162nd to 165th operation cycles of JMTR as irradiation and PIE technique development for lifetime expansion of beryllium frames. The design study of irradiation capsule, development of dismount device of irradiation capsule and the high accuracy size measurement device were carried out. The PIEs such as tensile tests, metallurgical observation, and size change measurement were also carried out with two kinds of irradiated beryllium metals (S-200F and S-65C). (author)

  8. Release of beryllium from mineral ores in artificial lung and skin surface fluids.

    Science.gov (United States)

    Duling, Matthew G; Stefaniak, Aleksandr B; Lawrence, Robert B; Chipera, Steve J; Virji, M Abbas

    2012-06-01

    Exposure to some manufactured beryllium compounds via skin contact or inhalation can cause sensitization. A portion of sensitized persons who inhale beryllium may develop chronic beryllium disease (CBD). Little is understood about exposures to naturally occurring beryllium minerals. The purpose of this study was to assess the bioaccessibility of beryllium from bertrandite ore. Dissolution of bertrandite from two mine pits (Monitor and Blue Chalk) was evaluated for both the dermal and inhalation exposure pathways by determining bioaccessibility in artificial sweat (pH 5.3 and pH 6.5), airway lining fluid (SUF, pH 7.3), and alveolar macrophage phagolysosomal fluid (PSF, pH 4.5). Significantly more beryllium was released from Monitor pit ore than Blue Chalk pit ore in artificial sweat buffered to pH 5.3 (0.88 ± 0.01% vs. 0.36 ± 0.00%) and pH 6.5 (0.09 ± 0.00% vs. 0.03 ± 0.01%). Rates of beryllium released from the ores in artificial sweat were faster than previously measured for manufactured forms of beryllium (e.g., beryllium oxide), known to induce sensitization in mice. In SUF, levels of beryllium were below the analytical limit of detection. In PSF, beryllium dissolution was biphasic (initial rapid diffusion followed by latter slower surface reactions). During the latter phase, dissolution half-times were 1,400 to 2,000 days, and rate constants were ~7 × 10(-10) g/(cm(2)·day), indicating that bertrandite is persistent in the lung. These data indicate that it is prudent to control skin and inhalation exposures to bertrandite dusts. PMID:21866318

  9. Measurement of Autism: A Review of Four Screening Measures

    OpenAIRE

    Nishalie Fernandopulle

    2011-01-01

    Using a key word search on electronic databases, two relevant journals and relevant review references, four measures of autistic symptoms (Childhood Asperger Syndrome Test, Autism Behavior Checklist, Social Communication Questionnaire, Social Responsiveness Scale) were reviewed with reference to their ability to discriminate the three major components of autism and measure across the whole spectrum of autism. None of the reviewed measures were able to effectively tap into and differentiate be...

  10. Assessment of soil contamination. Measuring devices for arsenic, berryllium, lead, cadmium, mercury and selenium. Wirkung von Bodenkontaminationen. Messlatten fuer Arsen, Beryllium, Blei, Cadmium, Quecksilber und Selen

    Energy Technology Data Exchange (ETDEWEB)

    Blumenbach, D.; Kloke, A.; Luehr, H.P.

    1991-12-01

    To assess soil contamination with respect to the suitability of the site concerned, it is essential to obtain knowledge of the relationship between soil contamination levels and the effect of the contaminants on a targets meriting protection (e.g. human beings, plants, soil organisms). In this final report, data obtained from literature on the inorganic pollutants arsenic, lead, cadmium, mercury, selenium and beryllium are compiled, and for selected targets an overview is given of the damage occurring at the various concentration levels studies. The present data, together with information on the envisaged use of the site and on soil properties influencing the pollutant's transport to the protected target, can be used to assess soil quality. Threshold values for use in decision-making cannot be derived directly from the presented data, as such data can only convey a picture of the range of the harmful concentrations given in the literature. (orig.).

  11. Erosion of beryllium under ITER – Relevant transient plasma loads

    Energy Technology Data Exchange (ETDEWEB)

    Kupriyanov, I.B., E-mail: igkupr@gmail.com [A.A. Bochvar High Technology Research Institute of Inorganic Materials, Rogova St. 5a, 123060 Moscow (Russian Federation); Nikolaev, G.N.; Kurbatova, L.A.; Porezanov, N.P. [A.A. Bochvar High Technology Research Institute of Inorganic Materials, Rogova St. 5a, 123060 Moscow (Russian Federation); Podkovyrov, V.L.; Muzichenko, A.D.; Zhitlukhin, A.M. [TRINITI, Troitsk, Moscow reg. (Russian Federation); Gervash, A.A. [Efremov Research Institute, S-Peterburg (Russian Federation); Safronov, V.M. [Project Center of ITER, Moscow (Russian Federation)

    2015-08-15

    Highlights: • We study the erosion, mass loss/gain and surface structure evolution of Be/CuCrZr mock-ups, armored with beryllium of TGP-56FW grade after irradiation by deuterium plasma heat load of 0.5 MJ/m{sup 2} at 250 °C and 500 °C. • Beryllium mass loss/erosion under plasma heat load at 250 °C is rather small (no more than 0.2 g/m{sup 2} shot and 0.11 μm/shot, correspondingly, after 40 shots) and tends to decrease with increasing number of shots. • Beryllium mass loss/erosion under plasma heat load at 500 °C is much higher (∼2.3 g/m{sup 2} shot and 1.2 μm/shot, correspondingly, after 10 shot) and tends to decrease with increasing the number of shots (∼0.26 g/m{sup 2} pulse and 0.14 μm/shot, correspondingly, after 100 shot). • Beryllium erosion value derived from the measurements of profile of irradiated surface is much higher than erosion value derived from mass loss data. - Abstract: Beryllium will be used as a armor material for the ITER first wall. It is expected that erosion of beryllium under transient plasma loads such as the edge-localized modes (ELMs) and disruptions will mainly determine a lifetime of the ITER first wall. This paper presents the results of recent experiments with the Russian beryllium of TGP-56FW ITER grade on QSPA-Be plasma gun facility. The Be/CuCrZr mock-ups were exposed to up to 100 shots by deuterium plasma streams (5 cm in diameter) with pulse duration of 0.5 ms and heat loads range of 0.2–0.5 MJ/m{sup 2} at different temperature of beryllium tiles. The temperature of Be tiles has been maintained about 250 and 500 °C during the experiments. After 10, 40 and 100 shots, the beryllium mass loss/gain under erosion process were investigated as well as evolution of surface microstructure and cracks morphology.

  12. Defense programs beryllium good practice guide

    International Nuclear Information System (INIS)

    Within the DOE, it has recently become apparent that some contractor employees who have worked (or are currently working) with and around beryllium have developed chronic beryllium disease (CBD), an occupational granulomatous lung disorder. Respiratory exposure to aerosolized beryllium, in susceptible individuals, causes an immunological reaction that can result in granulomatous scarring of the lung parenchyma, shortness of breath, cough, fatigue, weight loss, and, ultimately, respiratory failure. Beryllium disease was originally identified in the 1940s, largely in the fluorescent light industry. In 1950, the Atomic Energy Commission (AEC) introduced strict exposure standards that generally curtailed both the acute and chronic forms of the disease. Beginning in 1984, with the identification of a CBD case in a DOE contractor worker, there was increased scrutiny of both industrial hygiene practices and individuals in this workforce. To date, over 100 additional cases of beryllium-specific sensitization and/or CBD have been identified. Thus, a disease previously thought to be largely eliminated by the adoption of permissible exposure standards 45 years ago is still a health risk in certain workforces. This good practice guide forms the basis of an acceptable program for controlling workplace exposure to beryllium. It provides (1) Guidance for minimizing worker exposure to beryllium in Defense Programs facilities during all phases of beryllium-related work, including the decontamination and decommissioning (D ampersand D) of facilities. (2) Recommended controls to be applied to the handling of metallic beryllium and beryllium alloys, beryllium oxide, and other beryllium compounds. (3) Recommendations for medical monitoring and surveillance of workers exposed (or potentially exposed) to beryllium, based on the best current understanding of beryllium disease and medical diagnostic tests available. (4) Site-specific safety procedures for all processes of beryllium that is

  13. Field-emission spectroscopy of beryllium atoms adsorbed on tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Czyzewski, J.J.; Grzesiak, W.; Krajniak, J. (Politechnika Wroclawska (Poland))

    1981-01-01

    Field emission energy distributions (FEED) have been measured for the beryllium-tungsten (023) adsorption system over the 78-450 K temperature range. A temperature dependence of the normalized half-width, ..delta../d, of FEED peaks changed significantly due to beryllium adsorption; and the curve, ..delta../d vs p, for the Be/W adsorption system was identical in character to the calculated curve based on the free electron model in contrast to the curve for the clean tungsten surface. In the last part of this paper Gadzuk's theory of the resonance-tunneling effect is applied to the beryllium atom on tungsten. Experimental and theoretical curves of the enhancement factor as a function of energy have been discussed.

  14. Protection of beryllium metal against microbial influenced corrosion using silane self-assembled monolayers

    Science.gov (United States)

    Vaidya, Rajendra U.; Deshpande, Alina; Hersman, Larry; Brozik, Susan M.; Butt, Darryl

    1999-08-01

    The effectiveness of a self-assembled silane monolayer as protection for beryllium against microbiologically influenced corrosion (MIC) was demonstrated. Four-point bend tests on coated and uncoated beryllium samples were conducted after microbiological exposures, and the effectiveness of these coatings as MIC protection was reported through mechanical property evaluations. Application of the silane monolayer to the beryllium surfaces was found to prevent degradation of the failure strength and displacement-to-failure of beryllium in bending. In contrast, the uncoated beryllium samples exhibited a severe reduction in these mechanical properties in the presence of the marine Pseudomonas bacteria. The potentiodynamic measurements showed that both the uncoated and coated samples pitted at the open-circuit potential. However, the size and distribution of the corrosion pits formed on the surface of the beryllium samples were significantly different for the various cases (coated vs uncoated samples exposed to control vs inoculated medium). This study demonstrates the following: (1) the deleterious effects of MIC on the mechanical properties of beryllium and (2) the potential for developing fast, easy, and cost-effective MIC protection for beryllium metal using silane self-assemblies.

  15. Measurement of autism: a review of four screening measures.

    Science.gov (United States)

    Fernandopulle, Nishalie

    2011-01-01

    Using a key word search on electronic databases, two relevant journals and relevant review references, four measures of autistic symptoms (Childhood Asperger Syndrome Test, Autism Behavior Checklist, Social Communication Questionnaire, Social Responsiveness Scale) were reviewed with reference to their ability to discriminate the three major components of autism and measure across the whole spectrum of autism. None of the reviewed measures were able to effectively tap into and differentiate between all points on the spectrum. Further work is required to assess the sensitivity of the measures to independence between domains. The development of a measure sensitive to symptom change/continuity across development may be useful. PMID:22021947

  16. Measurement of autism: A review of four screening measures

    Directory of Open Access Journals (Sweden)

    Nishalie Fernandopulle

    2011-01-01

    Full Text Available Using a key word search on electronic databases, two relevant journals and relevant review references, four measures of autistic symptoms (Childhood Asperger Syndrome Test, Autism Behavior Checklist, Social Communication Questionnaire, Social Responsiveness Scale were reviewed with reference to their ability to discriminate the three major components of autism and measure across the whole spectrum of autism. None of the reviewed measures were able to effectively tap into and differentiate between all points on the spectrum. Further work is required to assess the sensitivity of the measures to independence between domains. The development of a measure sensitive to symptom change/continuity across development may be useful.

  17. Reactivity test between beryllium and copper

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, H. [Japan Atomic Energy Research Institute, Ibaraki-ken (Japan); Kato, M. [NGK Insulators, Ltd., Aichi-ken (Japan)

    1995-09-01

    Beryllium has been expected for using as plasma facing material on ITER. And, copper alloy has been proposed as heat sink material behind plasma facing components. Therefore, both materials must be joined. However, the elementary process of reaction between beryllium and copper alloy does not clear in detail. For example, other authors reported that beryllium reacted with copper at high temperature, but it was not obvious about the generation of reaction products and increasing of the reaction layer. In the present work, from this point, for clarifying the elementary process of reaction between beryllium and copper, the out-of-pile compatibility tests were conducted with diffusion couples of beryllium and copper which were inserted in the capsule filled with high purity helium gas (6N). Annealing temperatures were 300, 400, 500, 600 and 700{degrees}C, and annealing periods were 100, 300 and 1000h. Beryllium specimens were hot pressed beryllium, and copper specimens were OFC (Oxygen Free Copper).

  18. Worker Environment Beryllium Characterization Study

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environment, Safety, Health & Quality

    2009-12-28

    This report summarizes the conclusion of regular monitoring of occupied buildings at the Nevada Test Site and North Las Vegas facility to determine the extent of beryllium (Be) contamination in accordance with Judgment of Needs 6 of the August 14, 2003, “Minnema Report.”

  19. Worker Environment Beryllium Characterization Study

    International Nuclear Information System (INIS)

    This report summarizes the conclusion of regular monitoring of occupied buildings at the Nevada Test Site and North Las Vegas facility to determine the extent of beryllium (Be) contamination in accordance with Judgment of Needs 6 of the August 14, 2003, 'Minnema Report.'

  20. Neutron irradiation behavior of ITER candidate beryllium grades

    Energy Technology Data Exchange (ETDEWEB)

    Kupriyanov, I.B.; Gorokhov, V.A.; Nikolaev, G.N. [A.A.Bochvar All-Russia Scientific Research Inst. of Inorganic Materials (VNIINM), Moscow (Russian Federation); Melder, R.R.; Ostrovsky, Z.E.

    1998-01-01

    Beryllium is one of the main candidate materials both for the neutron multiplier in a solid breeding blanket and for the plasma facing components. That is why its behaviour under the typical for fusion reactor loading, in particular, under the neutron irradiation is of a great importance. This paper presents mechanical properties, swelling and microstructure of six beryllium grades (DshG-200, TR-30, TshG-56, TRR, TE-30, TIP-30) fabricated by VNIINM, Russia and also one - (S-65) fabricated by Brush Wellman, USA. The average grain size of the beryllium grades varied from 8 to 25 {mu}m, beryllium oxide content was 0.8-3.2 wt. %, initial tensile strength was 250-680 MPa. All the samples were irradiated in active zone of SM-3 reactor up to the fast neutron fluence (5.5-6.2) {center_dot} 10{sup 21} cm{sup -2} (2.7-3.0 dpa, helium content up to 1150 appm), E > 0.1 MeV at two temperature ranges: T{sub 1} = 130-180degC and T{sub 2} = 650-700degC. After irradiation at 130-180degC no changes in samples dimensions were revealed. After irradiation at 650-700degC swelling of the materials was found to be in the range 0.1-2.1 %. Beryllium grades TR-30 and TRR, having the smallest grain size and highest beryllium oxide content, demonstrated minimal swelling, which was no more than 0.1 % at 650-700degC and fluence 5.5 {center_dot} 10{sup 21} cm{sup -2}. Tensile and compression test results and microstructure parameters measured before and after irradiation are also presented. (author)

  1. Dose reduction in computed tomography: the effect of eye and testicle shielding on radiation dose measured in patients with beryllium oxide-based optically stimulated luminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Grobe, Henrik; Koch, Arne; Abolmaali, Nasreddin [Dresden University of Technology, OncoRay - Center for Radiation Research in Oncology, Molecular Imaging, Medical Faculty Carl Gustav Carus, Fetscherstrasse 74, P.O. Box 86, Dresden (Germany); Sommer, Marian; Henniger, Juergen [Dresden University of Technology, Radiation Physics Group, Institute of Nuclear and Particle Physics, Dresden (Germany); Hietschold, Volker [University Hospital Carl Gustav Carus, Institute and Policlinic of Radiological Diagnostics, Dresden (Germany)

    2009-05-15

    The aim of this study was to assess the effect of eye and testicle shielding on radiation dose to the lens and the testes of patients undergoing CT examinations. Fifty-one male patients underwent CT twice with identical protocols initially without, the second time with protective garments. Doses to the testes and the lenses were recorded with beryllium oxide-based dosimeters. The dose to the testes and lenses from CT exposure was reduced by 96.2% {+-} 1.7% and 28.2% {+-} 18.5%, when testicle and eye shielding was used, respectively. The effect of the eye shielding on the eye lens dose was found to depend on the x-ray tube position when the eye is primarily exposed during the scan. The maximum eye lens dose reduction achieved was found to be 43.2% {+-} 6.5% corresponding to the anterior position of the tube. A significant correlation between the patient's body mass index and dose exposure could not be found. Eye and testicle shields, apart from being inexpensive and easy to use, were proven to be effective in reducing eye lens and testicle radiation dose burden from CT exposures. (orig.)

  2. OVERVIEW OF BERYLLIUM SAMPLING AND ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    Brisson, M

    2009-04-01

    Because of its unique properties as a lightweight metal with high tensile strength, beryllium is widely used in applications including cell phones, golf clubs, aerospace, and nuclear weapons. Beryllium is also encountered in industries such as aluminium manufacturing, and in environmental remediation projects. Workplace exposure to beryllium particulates is a growing concern, as exposure to minute quantities of anthropogenic forms of beryllium may lead to sensitization and to chronic beryllium disease, which can be fatal and for which no cure is currently known. Furthermore, there is no known exposure-response relationship with which to establish a 'safe' maximum level of beryllium exposure. As a result, the current trend is toward ever lower occupational exposure limits, which in turn make exposure assessment, both in terms of sampling and analysis, more challenging. The problems are exacerbated by difficulties in sample preparation for refractory forms of beryllium, such as beryllium oxide, and by indications that some beryllium forms may be more toxic than others. This chapter provides an overview of sources and uses of beryllium, health risks, and occupational exposure limits. It also provides a general overview of sampling, analysis, and data evaluation issues that will be explored in greater depth in the remaining chapters. The goal of this book is to provide a comprehensive resource to aid personnel in a wide variety of disciplines in selecting sampling and analysis methods that will facilitate informed decision-making in workplace and environmental settings.

  3. Beryllium - A Unique Material in Nuclear Applications

    International Nuclear Information System (INIS)

    Beryllium, due to its unique combination of structural, chemical, atomic number, and neutron absorption cross section characteristics, has been used successfully as a neutron reflector for three generations of nuclear test reactors at the Idaho National Engineering and Environmental Laboratory (INEEL). The Advanced Test Reactor (ATR), the largest test reactor in the world, has utilized five successive beryllium neutron reflectors and is scheduled for continued operation with a sixth beryllium reflector. A high radiation environment in a test reactor produces radiation damage and other changes in beryllium. These changes necessitate safety analysis of the beryllium, methods to predict performance, and appropriate surveillances. Other nuclear applications also utilize beryllium. Beryllium, given its unique atomic, physical, and chemical characteristics, is widely used as a ''window'' for x-rays and gamma rays. Beryllium, intimately mixed with high-energy alpha radiation emitters has been successfully used to produce neutron sources. This paper addresses operational experience and methodologies associated with the use of beryllium in nuclear test reactors and in ''windows'' for x-rays and gamma rays. Other nuclear applications utilizing beryllium are also discussed

  4. Defense programs beryllium good practice guide

    Energy Technology Data Exchange (ETDEWEB)

    Herr, M.

    1997-07-01

    Within the DOE, it has recently become apparent that some contractor employees who have worked (or are currently working) with and around beryllium have developed chronic beryllium disease (CBD), an occupational granulomatous lung disorder. Respiratory exposure to aerosolized beryllium, in susceptible individuals, causes an immunological reaction that can result in granulomatous scarring of the lung parenchyma, shortness of breath, cough, fatigue, weight loss, and, ultimately, respiratory failure. Beryllium disease was originally identified in the 1940s, largely in the fluorescent light industry. In 1950, the Atomic Energy Commission (AEC) introduced strict exposure standards that generally curtailed both the acute and chronic forms of the disease. Beginning in 1984, with the identification of a CBD case in a DOE contractor worker, there was increased scrutiny of both industrial hygiene practices and individuals in this workforce. To date, over 100 additional cases of beryllium-specific sensitization and/or CBD have been identified. Thus, a disease previously thought to be largely eliminated by the adoption of permissible exposure standards 45 years ago is still a health risk in certain workforces. This good practice guide forms the basis of an acceptable program for controlling workplace exposure to beryllium. It provides (1) Guidance for minimizing worker exposure to beryllium in Defense Programs facilities during all phases of beryllium-related work, including the decontamination and decommissioning (D&D) of facilities. (2) Recommended controls to be applied to the handling of metallic beryllium and beryllium alloys, beryllium oxide, and other beryllium compounds. (3) Recommendations for medical monitoring and surveillance of workers exposed (or potentially exposed) to beryllium, based on the best current understanding of beryllium disease and medical diagnostic tests available. (4) Site-specific safety procedures for all processes of beryllium that is likely to

  5. Beryllium abundances in stars with planets:Extending the sample

    CERN Document Server

    Gálvez-Ortiz, M C; Hernández, J I González; Israelian, G; Santos, N C; Rebolo, R; Ecuvillon, A

    2011-01-01

    Context: Chemical abundances of light elements as beryllium in planet-host stars allow us to study the planet formation scenarios and/or investigate possible surface pollution processes. Aims: We present here an extension of previous beryllium abundance studies. The complete sample consists of 70 stars hosting planets and 30 stars without known planetary companions. The aim of this paper is to further assess the trends found in previous studies with less number of objects. This will provide more information on the processes of depletion and mixing of light elements in the interior of late type stars, and will provide possible explanations for the abundance differences between stars that host planets and "single" stars. Methods: Using high resolution UVES spectra, we measure beryllium abundances of 26 stars that host planets and 1 "single" star mainly using the \\lambda 3131.065 A Be II line, by fitting synthetic spectra to the observational data. We also compile beryllium abundance measurements of 44 stars hos...

  6. Mutagenicity, carcinogenicity and teratogenicity of beryllium.

    Science.gov (United States)

    Léonard, A; Lauwerys, R

    1987-07-01

    The carcinogenicity of a number of beryllium compounds has been confirmed in experiments on laboratory animals and this metal has to be treated as a possible carcinogenic threat to man. These carcinogenic properties are associated with mutagenic activity as shown by the results of short-term tests performed in vitro with beryllium chloride and beryllium sulfate. These soluble beryllium compounds can produce some infidelity of in vitro synthesis, forward gene mutations in microorganisms and in mammalian cells. They are also able to induce cell transformation. In addition to the positive results obtained in several short-term assays beryllium compounds have been found to bind to nucleoproteins, to inhibit certain enzymes needed for DNA synthesis, to bind nucleic acids to cell membranes and to inhibit microtubule polymerization. The teratogenicity of beryllium salts is relatively unknown and needs additional investigation.

  7. Inhibited solid propellant composition containing beryllium hydride

    Science.gov (United States)

    Thompson, W. W. (Inventor)

    1978-01-01

    An object of this invention is to provide a composition of beryllium hydride and carboxy-terminated polybutadiene which is stable. Another object of this invention is to provide a method for inhibiting the reactivity of beryllium hydride toward carboxy-terminated polybutadiene. It was found that a small amount of lecithin inhibits the reaction of beryllium hydride with the acid groups in carboxy terminated polybutadiene.

  8. Stellar abundances of beryllium and CUBES

    CERN Document Server

    Smiljanic, R

    2014-01-01

    Stellar abundances of beryllium are useful in different areas of astrophysics, including studies of the Galactic chemical evolution, of stellar evolution, and of the formation of globular clusters. Determining Be abundances in stars is, however, a challenging endeavor. The two Be II resonance lines useful for abundance analyses are in the near UV, a region strongly affected by atmospheric extinction. CUBES is a new spectrograph planned for the VLT that will be more sensitive than current instruments in the near UV spectral region. It will allow the observation of fainter stars, expanding the number of targets where Be abundances can be determined. Here, a brief review of stellar abundances of Be is presented together with a discussion of science cases for CUBES. In particular, preliminary simulations of CUBES spectra are presented, highlighting its possible impact in investigations of Be abundances of extremely metal-poor stars and of stars in globular clusters.

  9. Sampling for Passive Internet Measurement: A Review

    OpenAIRE

    Duffield, Nick

    2004-01-01

    Sampling has become an integral part of passive network measurement. This role is driven by the need to control the consumption of resources in the measurement infrastructure under increasing traffic rates and the demand for detailed measurements from applications and service providers. Classical sampling methods play an important role in the current practice of Internet measurement. The aims of this review are (i) to explain the classical sampling methodology in the context of the Internet t...

  10. New and Emerging Technologies for Real-Time Air and Surface Beryllium Monitoring; FINAL

    International Nuclear Information System (INIS)

    In this study, five emerging technologies were identified for real-time monitoring of airborne beryllium: Microwave-Induced Plasma Spectroscopy (MIPS), Aerosol Beam-Focused Laser-Induced Plasma Spectroscopy (ABFLIPS), Laser-Induced Breakdown Spectroscopy (LIBS), Surfaced-Enhanced Raman Scattering (SERS) Spectroscopy, and Micro-Calorimetric Spectroscopy (CalSpec). Desired features of real-time air beryllium monitoring instrumentation were developed from the Y-12 CBDPP. These features were used as guidelines for the identification of potential technologies as well as their unique demonstrated capability to provide real-time monitoring of similar materials. However, best available technologies were considered, regardless of their ability to comply with the desired features. None of the five technologies have the capability to measure the particle size of airborne beryllium. Although reducing the total concentration of airborne beryllium is important, current literature suggests that reducing or eliminating the concentration of respirable beryllium is critical for worker health protection. Eight emerging technologies were identified for surface monitoring of beryllium. CalSpec, MIPS, SERS, LIBS, Laser Ablation, Absorptive Stripping Voltametry (ASV), Modified Inductively Coupled Plasma (ICP) Spectroscopy, and Gamma BeAST. Desired features of real-time surface beryllium monitoring were developed from the Y-12 CBDPP. These features were used as guidelines for the identification of potential technologies. However, the best available technologies were considered regardless of their ability to comply with the desired features

  11. Development of radiation resistant grades of beryllium for nuclear and fusion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kupriyanov, I.B.; Gorokhov, V.A.; Nikolaev, G.N. [Russia Research Institute of Inorganic Materials, Moscow (Russian Federation)

    1995-09-01

    R&D results on beryllium with high radiation resistance obtained recently are described in this report. The data are presented on nine different grades of isotropic beryllium manufactured by VNIINM and distinguished by both initial powder characteristics and properties of billets, made of these powders. The average grain size of the investigated beryllium grades varied from 8 to 26 {mu}m, the content of beryllium oxide was 0.9 - 3.9 wt.%, the dispersity of beryllium oxide - 0.04 - 0.5 {mu}m, tensile strength -- 250 - 650 MPa. All materials were irradiated in SM - 2 reactor over the temperature range 550 - 780{degrees}C. The results of the investigation showed, that HIP beryllium grades are less susceptible to swelling at higher temperatures in comparison with hot pressed and extruded grades. Beryllium samples, having the smallest grain size, demonstrated minimal swelling, which was less than 0.8 % at 750{degrees}C and Fs = 3.7 {center_dot}10{sup 21} cm{sup -2} (E>0.1 MeV). The mechanical properties, creep and microstructure parameters, measured before and after irradiation, are presented.

  12. New and Emerging Technologies for Real-Time Air and Surface Beryllium Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Phifer, B.E. Jr.; Churnetski, E.L.; Cooke, L.E.; Reed, J.J.; Howell, M.L.; Smith, V.D.

    2001-09-01

    In this study, five emerging technologies were identified for real-time monitoring of airborne beryllium: Microwave-Induced Plasma Spectroscopy (MIPS), Aerosol Beam-Focused Laser-Induced Plasma Spectroscopy (ABFLIPS), Laser-Induced Breakdown Spectroscopy (LIBS), Surfaced-Enhanced Raman Scattering (SERS) Spectroscopy, and Micro-Calorimetric Spectroscopy (CalSpec). Desired features of real-time air beryllium monitoring instrumentation were developed from the Y-12 CBDPP. These features were used as guidelines for the identification of potential technologies as well as their unique demonstrated capability to provide real-time monitoring of similar materials. However, best available technologies were considered, regardless of their ability to comply with the desired features. None of the five technologies have the capability to measure the particle size of airborne beryllium. Although reducing the total concentration of airborne beryllium is important, current literature suggests that reducing or eliminating the concentration of respirable beryllium is critical for worker health protection. Eight emerging technologies were identified for surface monitoring of beryllium. CalSpec, MIPS, SERS, LIBS, Laser Ablation, Absorptive Stripping Voltametry (ASV), Modified Inductively Coupled Plasma (ICP) Spectroscopy, and Gamma BeAST. Desired features of real-time surface beryllium monitoring were developed from the Y-12 CBDPP. These features were used as guidelines for the identification of potential technologies. However, the best available technologies were considered regardless of their ability to comply with the desired features.

  13. Off the Beaten Track-A Hitchhiker's Guide to Beryllium Chemistry.

    Science.gov (United States)

    Naglav, Dominik; Buchner, Magnus R; Bendt, Georg; Kraus, Florian; Schulz, Stephan

    2016-08-26

    This Minireview aims to give an introduction to beryllium chemistry for all less-experienced scientists in this field of research. Up to date information on the toxicity of beryllium and its compounds are reviewed and several basic and necessary guidelines for a safe and proper handling in modern chemical research laboratories are presented. Interesting phenomenological observations are described that are related directly to the uniqueness of this element, which are also put into historical context. Herein we combine the contributions and experiences of many scientist that work passionately in this field. We want to encourage fellow scientists to reconcile the long-standing reservations about beryllium and its compounds and motivate intense research on this spurned element. Who on earth should be able to deal with beryllium and its compounds if not chemists? PMID:27364901

  14. Cosmis Lithium-Beryllium-Boron Story

    Science.gov (United States)

    Vangioni-Flam, E.; Cassé, M.

    Light element nucleosynthesis is an important chapter of nuclear astrophysics. Specifically, the rare and fragile light nuclei Lithium, Beryllium and Boron (LiBeB) are not generated in the normal course of stellar nucleosynthesis (except Lithium-7) and are, in fact, destroyed in stellar interiors. This characteristic is reflected in the low abundance of these simple species. Up to recently, the most plausible interpretation was that galactic cosmic rays (GCR) interact with interstellar CNO to form LiBeB. Other origins have been also identified, primordial and stellar (Lithium-7) and supernova neutrino spallation (Lithium-7 and Boron-11). In contrast, Beryllium-9, Boron-10 and Lithium-6 are pure spallative products. This last isotope presents a special interest since the Lithium-7/Lithium-6 ratio has been measured in a few halo stars offering a new constraint on the early galactic evolution. However, in the nineties, new observations prompted astrophysicists to reassess the question. Optical measurements of the beryllium and boron abundances in halo stars have been achieved by the 10 meters KECK telescope and the Hubble Space Telescope. These observations indicate a quasi linear correlation between Be and B vs Fe, at least at low metallicity, unexpected on the basis of GCR scenario, predicting a quadratic relationship. As a consequence, the origin and the evolution of the LiBeB nuclei has been revisited. This linearity implies the acceleration of C and O nuclei freshly synthesized and their fragmentation on the the interstellar Hydrogen and Helium. Wolf-Rayet stars and supernovae via the shock waves induced, are the best candidates to the acceleration of their own material enriched into C and O; so LiBeB is produced independently of the Interstellar Medium chemical composition. Moreover, neutrinos emitted by the newly born neutron stars interacting with the C layer of the supernova could produce specifically Lithium-7 and Boron-11. This process is supported by the

  15. Low-energy electronic stopping for boron in beryllium

    International Nuclear Information System (INIS)

    The range distribution for 50-keV boron bombarding beryllium was measured by an energetic ion-beam backscattering technique using helium ions. This distribution was compared with the range calculated with computer code EDEP1, with the result k 0.101 ± 0.013 for the electronic-stopping k-value. This value is compared with the results of recent interpolations from measurements of other elements. (author)

  16. Investigation of beryllium/steam interaction

    Energy Technology Data Exchange (ETDEWEB)

    Chekhonadskikh, A.M.; Vurim, A.D.; Vasilyev, Yu.S.; Pivovarov, O.S. [Inst. of Atomic Energy National Nuclear Center of the Republic of Kazakstan Semipalatinsk (Kazakhstan); Shestakov, V.P.; Tazhibayeva, I.L.

    1998-01-01

    In this report program on investigations of beryllium emissivity and transient processes on overheated beryllium surface attacked by water steam to be carried out in IAE NNC RK within Task S81 TT 2096-07-16 FR. The experimental facility design is elaborated in this Report. (author)

  17. Modeling of hydrogen interactions with beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Longhurst, G.R. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States)

    1998-01-01

    In this paper, improved mathematical models are developed for hydrogen interactions with beryllium. This includes the saturation effect observed for high-flux implantation of ions from plasmas and retention of tritium produced from neutronic transmutations in beryllium. Use of the models developed is justified by showing how they can replicated experimental data using the TMAP4 tritium transport code. (author)

  18. Investigation of the ion beryllium surface interaction

    Energy Technology Data Exchange (ETDEWEB)

    Guseva, M.I.; Birukov, A.Yu.; Gureev, V.M. [RRC Kurchatov Institute, Moscow (Russian Federation)] [and others

    1995-09-01

    The self -sputtering yield of the Be was measured. The energy dependence of the Be self-sputtering yield agrees well with that calculated by W. Eckstein et. al. Below 770 K the self-sputtering yield is temperature independent; at T{sub irr}.> 870 K it increases sharply. Hot-pressed samples at 370 K were implanted with monoenergetic 5 keV hydrogen ions and with a stationary plasma (flux power {approximately} 5 MW/m{sup 2}). The investigation of hydrogen behavior in beryllium shows that at low doses hydrogen is solved, but at doses {ge} 5x10{sup 22} m{sup -2} the bubbles and channels are formed. It results in hydrogen profile shift to the surface and decrease of its concentration. The sputtering results in further concentration decrease at doses > 10{sup 25}m{sup -2}.

  19. Assessment of LANL beryllium waste management documentation

    International Nuclear Information System (INIS)

    The objective of this report is to determine present status of the preparation and implementation of the various high priority documents required to properly manage the beryllium waste generated at the Laboratory. The documents being assessed are: Waste Acceptance Criteria, Waste Characterization Plan, Waste Certification Plan, Waste Acceptance Procedures, Waste Characterization Procedures, Waste Certification Procedures, Waste Training Procedures and Waste Recordkeeping Procedures. Beryllium is regulated (as a dust) under 40 CFR 261.33 as ''Discarded commercial chemical products, off specification species, container residues and spill residues thereof.'' Beryllium is also identified in the 3rd thirds ruling of June 1, 1990 as being restricted from land disposal (as a dust). The beryllium waste generated at the Laboratory is handled separately because beryllium has been identified as a highly toxic carcinogenic material

  20. Beryllium for fusion application - recent results

    Science.gov (United States)

    Khomutov, A.; Barabash, V.; Chakin, V.; Chernov, V.; Davydov, D.; Gorokhov, V.; Kawamura, H.; Kolbasov, B.; Kupriyanov, I.; Longhurst, G.; Scaffidi-Argentina, F.; Shestakov, V.

    2002-12-01

    The main issues for the application of beryllium in fusion reactors are analyzed taking into account the latest results since the ICFRM-9 (Colorado, USA, October 1999) and presented at 5th IEA Be Workshop (10-12 October 2001, Moscow Russia). Considerable progress has been made recently in understanding the problems connected with the selection of the beryllium grades for different applications, characterization of the beryllium at relevant operational conditions (irradiation effects, thermal fatigue, etc.), and development of required manufacturing technologies. The key remaining problems related to the application of beryllium as an armour in near-term fusion reactors (e.g. ITER) are discussed. The features of the application of beryllium and beryllides as a neutron multiplier in the breeder blanket for power reactors (e.g. DEMO) in pebble-bed form are described.

  1. Analysis of beryllium and depleted uranium: An overview of detection methods in aerosols and soils

    International Nuclear Information System (INIS)

    We conducted a survey of commercially available methods for analysis of beryllium and depleted uranium in aerosols and soils to find a reliable, cost-effective, and sufficiently precise method for researchers involved in environmental testing at the Yuma Proving Ground, Yuma, Arizona. Criteria used for evaluation include cost, method of analysis, specificity, sensitivity, reproducibility, applicability, and commercial availability. We found that atomic absorption spectrometry with graphite furnace meets these criteria for testing samples for beryllium. We found that this method can also be used to test samples for depleted uranium. However, atomic absorption with graphite furnace is not as sensitive a measurement method for depleted uranium as it is for beryllium, so we recommend that quality control of depleted uranium analysis be maintained by testing 10 of every 1000 samples by neutron activation analysis. We also evaluated 45 companies and institutions that provide analyses of beryllium and depleted uranium. 5 refs., 1 tab

  2. Analysis of beryllium and depleted uranium: An overview of detection methods in aerosols and soils

    Energy Technology Data Exchange (ETDEWEB)

    Camins, I.; Shinn, J.H.

    1988-06-01

    We conducted a survey of commercially available methods for analysis of beryllium and depleted uranium in aerosols and soils to find a reliable, cost-effective, and sufficiently precise method for researchers involved in environmental testing at the Yuma Proving Ground, Yuma, Arizona. Criteria used for evaluation include cost, method of analysis, specificity, sensitivity, reproducibility, applicability, and commercial availability. We found that atomic absorption spectrometry with graphite furnace meets these criteria for testing samples for beryllium. We found that this method can also be used to test samples for depleted uranium. However, atomic absorption with graphite furnace is not as sensitive a measurement method for depleted uranium as it is for beryllium, so we recommend that quality control of depleted uranium analysis be maintained by testing 10 of every 1000 samples by neutron activation analysis. We also evaluated 45 companies and institutions that provide analyses of beryllium and depleted uranium. 5 refs., 1 tab.

  3. A Systematic Review of Assessment Literacy Measures

    Science.gov (United States)

    Gotch, Chad M.; French, Brian F.

    2014-01-01

    This work systematically reviews teacher assessment literacy measures within the context of contemporary teacher evaluation policy. In this study, the researchers collected objective tests of assessment knowledge, teacher self-reports, and rubrics to evaluate teachers' work in assessment literacy studies from 1991 to 2012. Then they evaluated…

  4. Technical issues for beryllium use in fusion blanket applications

    International Nuclear Information System (INIS)

    Beryllium is an excellent non-fissioning neutron multiplier for fusion breeder and fusion electric blanket applications. This report is a compilation of information related to the use of beryllium with primary emphasis on the fusion breeder application. Beryllium resources, production, fabrication, properties, radiation damage and activation are discussed. A new theoretical model for beryllium swelling is presented

  5. Characterization of beryllium deformation using in-situ x-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Magnuson, Eric Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Donald William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Clausen, Bjorn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sisneros, Thomas A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Park, Jun-Sang [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-08-24

    Beryllium’s unique mechanical properties are extremely important in a number of high performance applications. Consequently, accurate models for the mechanical behavior of beryllium are required. However, current models are not sufficiently microstructure aware to accurately predict the performance of beryllium under a range of processing and loading conditions. Previous experiments conducted using the SMARTS and HIPPO instruments at the Lujan Center(LANL), have studied the relationship between strain rate and texture development, but due to the limitations of neutron diffraction studies, it was not possible to measure the response of the material in real-time. In-situ diffraction experiments conducted at the Advanced Photon Source have allowed the real time measurement of the mechanical response of compressed beryllium. Samples of pre-strained beryllium were reloaded orthogonal to their original load path to show the reorientation of already twinned grains. Additionally, the in-situ experiments allowed the real time tracking of twin evolution in beryllium strained at high rates. The data gathered during these experiments will be used in the development and validation of a new, microstructure aware model of the constitutive behavior of beryllium.

  6. Geochemistry of beryllium in Bulgarian coals

    Energy Technology Data Exchange (ETDEWEB)

    Eskenazy, Greta M. [Geology Department, University of Sofia ' St. Kl. Ohridski' , Tzar Osvoboditel 15, Sofia 1504 (Bulgaria)

    2006-04-03

    The beryllium content of about 3000 samples (coal, coaly shales, partings, coal lithotypes, and isolated coalified woods) from 16 Bulgarian coal deposits was determined by atomic emission spectrography. Mean Be concentrations in coal show great variability: from 0.9 to 35 ppm for the deposits studied. There was no clear-cut relationship between Be content and rank. The following mean and confidence interval Be values were measured: lignites, 2.6+/-0.8 ppm; sub-bituminous coals, 8.2+/-3.3 ppm; bituminous coals, 3.0+/-1.2 ppm; and anthracites, 19+/-9.0 ppm. The Be contents in coal and coaly shales for all deposits correlated positively suggesting a common source of the element. Many samples of the coal lithotypes vitrain and xylain proved to be richer in Be than the hosting whole coal samples as compared on ash basis. Up to tenfold increase in Be levels was routinely recorded in fusain. The ash of all isolated coalified woods was found to contain 1.1 to 50 times higher Be content relative to its global median value for coal inclusions. Indirect evidence shows that Be occurs in both organic and inorganic forms. Beryllium is predominantly organically bound in deposits with enhanced Be content, whereas the inorganic form prevails in deposits whose Be concentration approximates Clarke values. The enrichment in Be exceeding the coal Clarke value 2.4 to 14.5 times in some of the Bulgarian deposits is attributed to subsynchronous at the time of coal deposition hydrothermal and volcanic activity. (author)

  7. Measurement of solar neutrinos from the beryllium ray in the Borexino experiment: analysis of data from the CTF (Counting Test Facility) prototype after designing and validation of the fast digitizing system

    International Nuclear Information System (INIS)

    The Borexino experiment (BX), a collaboration involving nine countries, is located in the Gran Sasso underground laboratory, Italy. It aims to measure the solar neutrino flux from the beryllium line at 862 keV. It will be the first real-time solar neutrino measurement at such low energies. This demands rigorous control of radio-purity. The technical feasibility is being studied with the prototype called the Counting Test Facility (CTF). The College de France group is responsible for the fast digitizer boards (FADC) on BX. The FADC were designed by our laboratory and completed at the beginning of 2002. Prototype and first industrial boards have been installed on CTF for tests and are currently operating with photomultipliers. We developed FADC data acquisition software for CTF and BX. For BX, we use an online algorithm to reduce data flow, based on event coincidence detection and suppression of low energy events. We have been producing data with CTF since summer 2000, and with BX we have performed a variety of tests with the first air runs. CTF analysis concerns just FADC data, and a joint analysis of FADC-based electronics with the standard system installed by the Italian team. One can reconstruct event energy and coincidences using FADC with a precision similar to the standard electronics. The parallel analysis shows the importance of using a single digitizing electronic train with no dead time in order to measure contamination in the detector, to analyse photomultiplier after-pulses and to discriminate between alpha and beta events. Furthermore, several discrimination methods are studied for BX with simulations. (author)

  8. Beryllium, Lithium and Oxygen Abundances in F-type Stars

    CERN Document Server

    García-López, R J; Pérez de Taoro, M R; Casares, C; Rasilla, J L; Rebolo, R; Allende-Prieto, C

    1997-01-01

    Beryllium and oxygen abundances have been derived in a sample of F-type field stars for which lithium abundances had been measured previously, with the aim of obtaining observational constraints to discriminate between the different mixing mechanisms proposed. Mixing associated with the transport of angular momentum in the stellar interior and internal gravity waves within the framework of rotating evolutionary models, appear to be promising ways to explain the observations.

  9. Investigations of the ternary system beryllium-carbon-tungsten and analyses of beryllium on carbon surfaces; Untersuchung des ternaeren Systems Beryllium-Kohlenstoff-Wolfram und Betrachtungen von Beryllium auf Kohlenstoffoberflaechen

    Energy Technology Data Exchange (ETDEWEB)

    Kost, Florian

    2009-05-25

    . Depending on the layer sequence, carbide formation is complete in the temperature range between 570 and 770 K. Be{sub 2}W alloy formation only takes place if further metallic beryllium is available after carbide formation. Be{sub 2}C and Be{sub 2}W dissociate at temperatures T>1170 K. Based on RBS analysis of C/Be/W systems of several 100 nm thickness, the concentration dependent diffusion coefficient for Be in W was determined. Only Be{sub 12}W formation was observed due to the large beryllium reservoir. Carbide formation (Be{sub 2}C) is not observed until the alloy formation is completed. Furthermore, the first successful depth-resolved XPS measurements were performed on ternary layer systems using synchrotron radiation. The reactions in the ternary system are restricted to compounds that are already known from binary system investigations. No further Be, C, W-containing species are detected. Beryllium carbide is dominant in the system as long as it does not dissociate. (orig.)

  10. Environmental Measurements Laboratory program review, December 1983

    International Nuclear Information System (INIS)

    This volume contains all of the written material that was submitted to the panel of Reviewers in advance of a Program Review conducted by the US Department of Energy, Office of Health and Environmental Research at the Environmental Measurements Laboratory (EML) December 7-9, 1983. In addition to a general introduction there are nineteen papers grouped into the five broad program categories covering all of the scientific and engineering projects of the Laboratory: Natural Radioactivity and Radiation, Anthropogenic Radioactivity and Radiation, Non-nuclear, Quality Assurance, and Development and Support. These short articles, for the most part, focus on the rationale for EML's involvement in each project, emphasizing their relevance to the EML and Department of Energy missions. Project results and their interpretation were presented at the Review and can be found in the material referenced in this volume

  11. Environmental Measurements Laboratory program review, December 1983

    Energy Technology Data Exchange (ETDEWEB)

    Volchok, H.L.; de Planque, G. (EDS.)

    1984-03-01

    This volume contains all of the written material that was submitted to the panel of Reviewers in advance of a Program Review conducted by the US Department of Energy, Office of Health and Environmental Research at the Environmental Measurements Laboratory (EML) December 7-9, 1983. In addition to a general introduction there are nineteen papers grouped into the five broad program categories covering all of the scientific and engineering projects of the Laboratory: Natural Radioactivity and Radiation, Anthropogenic Radioactivity and Radiation, Non-nuclear, Quality Assurance, and Development and Support. These short articles, for the most part, focus on the rationale for EML's involvement in each project, emphasizing their relevance to the EML and Department of Energy missions. Project results and their interpretation were presented at the Review and can be found in the material referenced in this volume.

  12. Measuring Urban Traffic Congestion – A Review

    Directory of Open Access Journals (Sweden)

    Amudapuram Mohan Rao

    2012-12-01

    Full Text Available Traffic’ congestion has been one of major issues that most metropolises are facing. It is believed that identification of congestion is the first step for selecting appropriate mitigation measures. Congestion - both in perception and in reality - impacts the movement of people. Traffic congestion wastes time, energy and causes pollution. There are broadly two factors, which effect the congestion; (a micro-level factors (b macro-level factors that relate to overall demand for road use. Congestion is ‘triggered’ at the ‘micro’ level (e.g. on the road, and ‘driven’ at the ‘macro’ level. The micro level factors are, for example, many people want to move at the same time, too many vehicles for limited road space. On the other side, macro level factors are e.g. land-use patžterns, car ownership trends, regional economic dynamics, etc. This paper gives an overview and presents the possible ways to identify and measure metrics for urban arterial congestion. A systematic review is carried out, based on measurement metrics such as speed, travel time/delay and volume and level of service. The review covers distinct aspects like definition; measurement criteria followed by different countries/organizations. The strengths and weaknesses of these measures are discussed. Further, a short critique of measurement criteria is presented.

  13. Investigation of the mechanism of interaction of Lithium 6 ions on Beryllium 9

    International Nuclear Information System (INIS)

    The objective of this research on the interaction of Lithium 6 and Beryllium 9 ions is to obtain new indications on the mode of interaction of these heavy ions, and on the configuration of target nuclei and projectile nuclei. In a first part, the author presents and describes the experimental conditions which comprise a Van de Graaff accelerator, a source, a stripper, and a target. He reports the study of α particles emitted by the reaction between the Lithium and Beryllium ions: description of the experimental installation (irradiation chamber and method), presentation and interpretation of experimental results. In the next part, he reports the study of Lithium 7 and Beryllium 10 nuclides emitted by disintegration of Beryllium 11: description of experimental conditions, variations of cross sections, variation of the cross section rate, and interpretation. The author then addresses the study of the intervention of the mode of interaction by 15N compound nucleus in the reactions between lithium and beryllium ions: study of intensities of the different spectrum lines, measurement of the Doppler effect produced of the 479 keV line, interpretation of results. In conclusion, the author analyses the mechanism of interaction between lithium and beryllium ions, and discusses different theories: the Newns and Glendenning theories, and the Leigh theory

  14. Elastic, micro- and macroplastic properties of polycrystalline beryllium

    Science.gov (United States)

    Kardashev, B. K.; Kupriyanov, I. B.

    2011-12-01

    The Young's modulus and the internal friction of beryllium polycrystals (size grain from 6 to 60 μm) prepared by the powder metallurgy method have been studied as functions of the amplitude and temperature in the range from 100 to 873 K. The measurements have been performed using the composite piezoelectric vibrator method for longitudinal vibrations at frequencies about 100 kHz. Based on the acoustic measurements, the data have been obtained on the elastic and inelastic (microplastic) properties as functions of vibration stress amplitudes within the limits from 0.2 to 30-60 MPa. The microplastic deformation diagram is shown to become nonlinear at the amplitudes higher than 5 MPa. The beryllium mechanical characteristics (the yield strength σ 0.2, the ultimate strength σ u , and the conventional microscopic yield strength σ y ) obtained with various grain sizes are compared. At room temperature, all the parameters satisfactorily obey the Hall-Petch relationship, although there is no complete similarity. The temperature dependences are quite different, namely: σ 0.2( T) and σ u ( T) decrease monotonically during heating from room temperature to higher temperatures; however, σ y ( T) behaves unusually, and it has a minimum near 400 K. The different levels of stresses and the absence of similarity indicate that the scattering of the ultrasound energy and the formation of a level of the macroscopic flow stresses in beryllium occur on dislocation motion obstacles of different origins.

  15. Lithium-Beryllium-Boron : Origin and Evolution

    OpenAIRE

    Vangioni-Flam, Elisabeth; Casse, Michel; Audouze, Jean

    1999-01-01

    The origin and evolution of Lithium-Beryllium-Boron is a crossing point between different astrophysical fields : optical and gamma spectroscopy, non thermal nucleosynthesis, Big Bang and stellar nucleosynthesis and finally galactic evolution. We describe the production and the evolution of Lithium-Beryllium-Boron from Big Bang up to now through the interaction of the Standard Galactic Cosmic Rays with the interstellar medium, supernova neutrino spallation and a low energy component related to...

  16. Mechanical properties of S-65C grade beryllium at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Goods, S.H. [Sandia National Lab., Livermore, CA (United States); Dombrowski, D.E.

    1998-01-01

    Tensile property measurements and fractographic analysis of S-65C beryllium are reviewed. Tests were performed on specimens oriented in the longitudinal and transverse directions with respect to the direction of vacuum hot-pressing. Specimens were tested in air at RT, 100degC, 200degC, 300degC, 415degC and 500degC at an initial strain rate of 1.1 x 10{sup -4} sec{sup -1}. Ductility of the material was strongly affected by the test temperature, exhibiting a peak ductility at 300degC. The material displayed a yield point phenomenon which was most pronounced at this same temperature. Scanning electron microscopy was performed on the resulting fracture surfaces and observations are reported. (author)

  17. Foot Plantar Pressure Measurement System: A Review

    Directory of Open Access Journals (Sweden)

    Yufridin Wahab

    2012-07-01

    Full Text Available Foot plantar pressure is the pressure field that acts between the foot and the support surface during everyday locomotor activities. Information derived from such pressure measures is important in gait and posture research for diagnosing lower limb problems, footwear design, sport biomechanics, injury prevention and other applications. This paper reviews foot plantar sensors characteristics as reported in the literature in addition to foot plantar pressure measurement systems applied to a variety of research problems. Strengths and limitations of current systems are discussed and a wireless foot plantar pressure system is proposed suitable for measuring high pressure distributions under the foot with high accuracy and reliability. The novel system is based on highly linear pressure sensors with no hysteresis.

  18. Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O₂ Fuel Rods (1.506-cm Pitch and 7-Tube Clusters)

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, Margaret A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Briggs, J. Blair [Idaho National Lab. (INL), Idaho Falls, ID (United States); Murphy, Michael F. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mihalczo, John T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-01

    Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one Na

  19. CRITICAL CONFIGURATION AND PHYSICS MEASUREMENTS FOR BERYLLIUM REFLECTED ASSEMBLIES OF U(93.15)O2 FUEL RODS (1.506-CM PITCH AND 7-TUBE CLUSTERS)

    Energy Technology Data Exchange (ETDEWEB)

    Margaret A. Marshall

    2014-03-01

    Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one Na

  20. Measurement of Pion and Kaon Fluxes Below 60 GeV/c Produced by 450~GeV/c Protons on a Beryllium Target The SPY Collaboration

    CERN Multimedia

    2002-01-01

    % NA56 \\\\ \\\\ We propose to perform a measurement of the production rates of $\\pi$'s and K's and their ratio below 60~GeV/c from 450~GeV/c protons hitting a Be target. These data are of great importance for the correct evaluation of the neutrino flux at the present and future SPS neutrino experiments. The apparatus of the NA52 experiment has the capability of performing the measurement, using about two weeks of proton beam time and a target closely resembling the one used in the current SPS neutrino beam line.

  1. Electronic band structure of beryllium oxide

    CERN Document Server

    Sashin, V A; Kheifets, A S; Ford, M J

    2003-01-01

    The energy-momentum resolved valence band structure of beryllium oxide has been measured by electron momentum spectroscopy (EMS). Band dispersions, bandwidths and intervalence bandgap, electron momentum density (EMD) and density of occupied states have been extracted from the EMS data. The experimental results are compared with band structure calculations performed within the full potential linear muffin-tin orbital approximation. Our experimental bandwidths of 2.1 +- 0.2 and 4.8 +- 0.3 eV for the oxygen s and p bands, respectively, are in accord with theoretical predictions, as is the s-band EMD after background subtraction. Contrary to the calculations, however, the measured p-band EMD shows large intensity at the GAMMA point. The measured full valence bandwidth of 19.4 +- 0.3 eV is at least 1.4 eV larger than the theory. The experiment also finds a significantly higher value for the p-to-s-band EMD ratio in a broad momentum range compared to the theory.

  2. Interaction of beryllium and hydrogen isotopes

    International Nuclear Information System (INIS)

    It has been considered that in the plasma nuclear fusion experimental devices of magnetic field confinement type, in order to reduce the energy loss due to bremsstrahlung, the use of the plasma-facing materials (PFM) of low atomic number like carbon is indispensable at present. Attention is paid to beryllium which is one of the PFMs, and its effectiveness was rocognized by the practical use in JET. When Be is considered as a PFM, it is necessary to accumulate many data on the diffusion, dissolution, permeation and surface recoupling of hydrogen isotopes, which regulate the recycling and inventory of deuterium and tritium fuel, and the relation of these factors with the physical and chemical states of Be. In this research, as the first phase of understanding the characteristics of Be as a PFM, the change of the surface condition by heating Be was investigated by X-ray photoelectron spectroscopy, and the chemical form of the Be-related substances emitted from the surface by argon or deuterium ion sputtering and their thermal behavior were measured by secondary ion mass spectrometry. The sample, the measurement and the results are reported. The diversified secondary ions of Be, Be cluster, Be oxide, hydroxide, hydride and deuteride were observed by the measurement, and their features are shown. (K.I.)

  3. High-resolution records of the beryllium-10 solar activity proxy in ice from Law Dome, East Antarctica: measurement, reproducibility and principal trends

    OpenAIRE

    J. B. Pedro; Smith, A M; Simon, K J; van Ommen, T. D.; M. A. J. Curran

    2011-01-01

    Three near-monthly resolution 10Be records are presented from the Dome Summit South (DSS) ice core site, Law Dome, East Antarctica. The chemical preparation and Accelerator Mass Spectrometer (AMS) measurement of these records is described. The reproducibility of 10Be records at DSS is assessed through intercomparison of the ice core data with data from two previously published and contemporaneous snow pits. We find generally good agreement between...

  4. Sanitary-hygienic and ecological aspects of beryllium production

    Energy Technology Data Exchange (ETDEWEB)

    Dvinskykh, E.M.; Savchuk, V.V.; Sidorov, V.L.; Slobodin, D.B.; Tuzov, Y.V. [Ulba Metallurgical Plant, Ust-Kamenogorsk (Kazakhstan)

    1998-01-01

    The Report describes An organization of sanitary-hygienic and ecological control of beryllium production at Ulba metallurgical plant. It involves: (1) the consideration of main methods for protection of beryllium production personnel from unhealthy effect of beryllium, (2) main kinds of filters, used in gas purification systems at different process areas, (3) data on beryllium monitoring in water, soil, on equipment. This Report also outlines problems connected with designing devices for a rapid analysis of beryllium in air as well as problems of beryllium production on ecological situation in the town. (author)

  5. Migration of Beryllium via Multiple Exposure Pathways among Work Processes in Four Different Facilities.

    Science.gov (United States)

    Armstrong, Jenna L; Day, Gregory A; Park, Ji Young; Stefaniak, Aleksandr B; Stanton, Marcia L; Deubner, David C; Kent, Michael S; Schuler, Christine R; Virji, M Abbas

    2014-01-01

    Inhalation of beryllium is associated with the development of sensitization; however, dermal exposure may also be important. The primary aim of this study was to elucidate relationships among exposure pathways in four different manufacturing and finishing facilities. Secondary aims were to identify jobs with increased levels of beryllium in air, on skin, and on surfaces; identify potential discrepancies in exposure pathways, and determine if these are related to jobs with previously identified risk. Beryllium was measured in air, on cotton gloves, and on work surfaces. Summary statistics were calculated and correlations among all three measurement types were examined at the facility and job level. Exposure ranking strategies were used to identify jobs with higher exposures. The highest air, glove, and surface measurements were observed in beryllium metal production and beryllium oxide ceramics manufacturing jobs that involved hot processes and handling powders. Two finishing and distribution facilities that handle solid alloy products had lower exposures than the primary production facilities, and there were differences observed among jobs. For all facilities combined, strong correlations were found between air-surface (rp ≥ 0.77), glove-surface (rp ≥ 0.76), and air-glove measurements (rp ≥ 0.69). In jobs where higher risk of beryllium sensitization or disease has been reported, exposure levels for all three measurement types were higher than in jobs with lower risk, though they were not the highest. Some jobs with low air concentrations had higher levels of beryllium on glove and surface wipe samples, suggesting a need to further evaluate the causes of the discrepant levels. Although such correlations provide insight on where beryllium is located throughout the workplace, they cannot identify the direction of the pathways between air, surface, or skin. Ranking strategies helped to identify jobs with the highest combined air, glove, and/or surface exposures

  6. Target particle and heat loads in low-triangularity L-mode plasmas in JET with carbon and beryllium/tungsten walls

    NARCIS (Netherlands)

    Groth, M.; Brezinsek, S.; Belo, P.; Corrigan, G.; Harting, D.; Wiesen, S.; Beurskens, M. N. A.; Brix, M.; Clever, M.; Coenen, J. W.; Eich, T.; Flanagan, J.; Giroud, C.; Huber, A.; Jachmich, S.; Kruezi, U.; Lehnen, M.; Lowry, C.; Maggi, C. F.; Marsen, S.; Meigs, A. G.; Sergienko, G.; Sieglin, B.; Silva, C.; Sirinelli, A.; Stamp, M. F.; van Rooij, G. J.

    2013-01-01

    Divertor radiation profiles, and power and particle fluxes to the target have been measured in attached \\{JET\\} L-mode plasmas with carbon and beryllium/tungsten wall materials. In the beryllium/tungsten configuration, factors of 2–3 higher power loads and peak temperatures at the low field side tar

  7. The use of a beryllium Hopkinson bar to characterize a piezoresistive accelerometer in shock environments

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, V.I.; Brown, F.A.; Davie, N.T.

    1996-03-01

    The characteristics of a piezoresistive accelerometer in shock environments are being studied at Sandia National Laboratories in the Mechanical Shock Testing Laboratory. A Hopkinson bar capability has been developed to extend our understanding of the piezoresistive accelerometer, in two mechanical configurations, in the high frequency, high shock environments where measurements are being made. In this paper, the beryllium Hopkinson bar configuration with a laser doppler vibrometer as the reference measurement is described. The in-axis performance of the piezoresistive accelerometer for frequencies of dc-50 kHz and shock magnitudes of up to 70,000 g as determined from measurements with a beryllium Hopkinson bar are presented. Preliminary results of characterizations of the accelerometers subjected to cross-axis shocks in a split beryllium Hopkinson bar configuration are presented.

  8. A role for cell adhesion in beryllium-mediated lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Hong-geller, Elizabeth [Los Alamos National Laboratory

    2008-01-01

    Chronic beryllium disease (CBD) is a debilitating lung disorder in which exposure to the lightweight metal beryllium (Be) causes the accumulation of beryllium-specific CD4+ T cells in the lung and formation of noncaseating pulmonary granulomas. Treatment for CBD patients who exhibit progressive pulmonary decline is limited to systemic corticosteroids, which suppress the severe host inflammatory response. Studies in the past several years have begun to highlight cell-cell adhesion interactions in the development of Be hypersensitivity and CBD. In particular, the high binding affinity between intercellular adhesion molecule 1 (I-CAM1) on lung epithelial cells and the {beta}{sub 2} integrin LFA-1 on migrating lymphocytes and macrophages regulates the concerted rolling of immune cells to sites of inflammation in the lung. In this review, we discuss the evidence that implicates cell adhesion processes in onset of Be disease and the potential of cell adhesion as an intervention point for development of novel therapies.

  9. Beryllium assessment and recommendation for application in ITER plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Barabash, V.; Tanaka, S.; Matera, R. [ITER Joint Central Team, Muenchen (Germany)

    1998-01-01

    The design status of the ITER Plasma Facing Components (PFC) is presented. The operational conditions of the armour material for the different components are summarized. Beryllium is the reference armour material for the Primary Wall, Baffle and Limiter and the back-up material for the Divertor Dome. The activities on the selection of the Be grades and the joining technologies are reviewed. (author)

  10. High-resolution records of the beryllium-10 solar activity proxy in ice from Law Dome, East Antarctica: measurement, reproducibility and principal trends

    Directory of Open Access Journals (Sweden)

    J. B. Pedro

    2011-07-01

    Full Text Available Three near-monthly resolution 10Be records are presented from the Dome Summit South (DSS ice core site, Law Dome, East Antarctica. The chemical preparation and Accelerator Mass Spectrometer (AMS measurement of these records is described. The reproducibility of 10Be records at DSS is assessed through intercomparison of the ice core data with data from two previously published and contemporaneous snow pits. We find generally good agreement between the five records, comparable to that observed between other trace chemical records from the site. This result allays concerns raised by a previous Antarctic study (Moraal et al., 2005 about poor reproducibility of ice core 10Be records. A single composite series is constructed from the three ice cores providing a monthly-resolved record of 10Be concentrations at DSS over the past decade (1999 to 2009. To our knowledge, this is the first published ice core data spanning the recent exceptional solar minimum of solar cycle 23. 10Be concentrations are significantly correlated to the cosmic ray flux recorded by the McMurdo neutron monitor (rxy = 0.64, with 95 % CI of 0.53 to 0.71, suggesting that solar modulation of the atmospheric production rate may explain up to ~40 % of the variance in 10Be concentrations at DSS. Sharp concentration peaks occur in most years during the summer-to-autumn, possibly caused by stratospheric incursions. Our results underscore the presence of both production and meteorological signals in ice core 10Be data.

  11. High-resolution records of the beryllium-10 solar activity proxy in ice from Law Dome, East Antarctica: measurement, reproducibility and principal trends

    Directory of Open Access Journals (Sweden)

    J. B. Pedro

    2011-02-01

    Full Text Available Three near-monthly resolution 10Be records are presented from the Dome Summit South (DSS ice core site, Law Dome, East Antarctica. The chemical preparation and Accelerator Mass Spectrometer (AMS measurement of these records is described. The reproducibility of 10Be records at DSS is assessed through intercomparison of the ice core data with data from two previously published and contemporaneous snow pits. We find generally good agreement between the five records, comparable to that observed between other trace chemical records from the site. This result allays concerns raised by a previous Antarctic study (Moraal et al., 2005 about poor reproducibility of ice core 10Be records. A single composite series is constructed from the three ice cores providing a monthly-resolved record of 10Be concentrations at DSS over the past decade (1999 to 2009. To our knowledge, this is the first published ice core data spanning the recent exceptional solar minimum of solar cycle 23. 10Be concentrations are significantly correlated to the cosmic ray flux recorded by the McMurdo neutron monitor (rxy = 0.64, with 95% CI of 0.53 to 0.71, suggesting that solar modulation of the atmospheric production rate may explain up to ~40% of the variance in 10Be concentrations at DSS. Sharp concentration peaks occur in most years during the summer-to-autumn, possibly caused by stratospheric incursions. Our results underscore the presence of both production and meteorological signals in ice core 10Be data.

  12. X-ray drive of beryllium capsule implosions at the National Ignition Facility

    Science.gov (United States)

    Wilson, D. C.; Yi, S. A.; Simakov, A. N.; Kline, J. L.; Kyrala, G. A.; Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Olson, R. E.; Strozzi, D. J.; Celliers, P. M.; Schneider, M. B.; MacPhee, A. G.; Zylstra, A. B.; Callahan, D. A.; Hurricane, O. A.; Milovich, J. L.; Hinkel, D. E.; Rygg, J. R.; Rinderknecht, H. G.; Sio, H.; Perry, T. S.; Batha, S.

    2016-05-01

    National Ignition Facility experiments with beryllium capsules have followed a path begun with “high-foot” plastic capsule implosions. Three shock timing keyhole targets, one symmetry capsule, a streaked backlit capsule, and a 2D backlit capsule were fielded before the DT layered shot. After backscatter subtraction, laser drive degradation is needed to match observed X-ray drives. VISAR measurements determined drive degradation for the picket, trough, and second pulse. Time dependence of the total Dante flux reflects degradation of the of the third laser pulse. The same drive degradation that matches Dante data for three beryllium shots matches Dante and bangtimes for plastic shots N130501 and N130812. In the picket of both Be and CH hohlraums, calculations over-estimate the x-ray flux > 1.8 keV by ∼100X, while calculating the total flux correctly. In beryllium calculations these X-rays cause an early expansion of the beryllium/fuel interface at ∼3 km/s. VISAR measurements gave only ∼0.3 km/s. The X-ray drive on the Be DT capsule was further degraded by an unplanned decrease of 9% in the total picket flux. This small change caused the fuel adiabat to rise from 1.8 to 2.3. The first NIF beryllium DT implosion achieved 29% of calculated yield, compared to CH capsules with 68% and 21%.

  13. Beryllium. Health hazards and their control. Pt. 2

    International Nuclear Information System (INIS)

    In this work (continuation of 'Beryllium' series) health hazards, toxic effects, limits of permissible atmospheric contamination and safe exposure to beryllium are described. Guidelines to the design, control operations and hygienic precautions of the working facilities are given. (Author)

  14. Steam-chemical reactivity for irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Anderl, R.A.; McCarthy, K.A.; Oates, M.A.; Petti, D.A.; Pawelko, R.J.; Smolik, G.R. [Idaho National Engineering and Environmental Lab., Idaho Falls, ID (United States)

    1998-01-01

    This paper reports the results of an experimental investigation to determine the influence of neutron irradiation effects and annealing on the chemical reactivity of beryllium exposed to steam. The work entailed measurements of the H{sub 2} generation rates for unirradiated and irradiated Be and for irradiated Be that had been previously annealed at different temperatures ranging from 450degC to 1200degC. H{sub 2} generation rates were similar for irradiated and unirradiated Be in steam-chemical reactivity experiments at temperatures between 450degC and 600degC. For irradiated Be exposed to steam at 700degC, the chemical reactivity accelerated rapidly and the specimen experienced a temperature excursion. Enhanced chemical reactivity at temperatures between 400degC and 600degC was observed for irradiated Be annealed at temperatures of 700degC and higher. This reactivity enhancement could be accounted for by the increased specific surface area resulting from development of a surface-connected porosity in the irradiated-annealed Be. (author)

  15. Micromechanical properties of beryllium and other instrument materials, end-of-year-report

    International Nuclear Information System (INIS)

    The objective of the program is to evaluate and understand the micromechanical properties of beryllium and other instrument materials for use in gyroscopes, so that dimensional instability can be improved. Improved dimensional stability is expected to lessen the need to periodically align gyroscopes in service. Drift in alignment has been attributed in part to mass shifts of 0.000001 inches in critical components of gyroscopes. This report consists of two major parts. Part A - Micromechanical properties of instrument grade beryllium. (description of the materials problem, instrumentation to make strain measurements in the range of 10 to the -7 power, and initial results.) Part B - 10 to the -8 power creep measurement system

  16. Occupational and non-occupational allergic contact dermatitis from beryllium.

    Science.gov (United States)

    Vilaplana, J; Romaguera, C; Grimalt, F

    1992-05-01

    There are various references to sensitization to beryllium in the literature. Since introducing a patch testing series for patients with suspected sensitization to metals, we have found 3 cases of sensitization to beryllium. Of these 3 cases, we regard the first 2 as having relevant sensitization. Beryllium chloride (1% pet.) was positive in 3 patients and negative in 150 controls.

  17. 75 FR 80734 - Chronic Beryllium Disease Prevention Program

    Science.gov (United States)

    2010-12-23

    ... Beryllium Disease Prevention Program (CBDPP) (63 FR 66940). After considering the comments received, DOE... CFR Part 850 RIN 1992-AA39 Chronic Beryllium Disease Prevention Program AGENCY: Office of Health... beryllium disease prevention program. The Department solicits comment and information on the...

  18. Spectrographic determination of impurities in beryllium oxide

    International Nuclear Information System (INIS)

    A method for the spectrographic determination of Al, B, Cd, Co, Cu, Cr, Fe, Mg, NaNi, Si and Zn in nuclear grade beryllium oxide has been developed. The determination of Co, Al, Na and Zn is besed upon a carrier distillation technique. Better results were obtained with 2% Ga2O3 as carrier in beryllium oxide. For the elements B, Cd, Cu, Fe, Cr, Mg, Ni and Si the sample is loaded in a Scribner-Mullin shallow cup electrode, covered with graphite powder and excited in DC arc. The relative standard deviation values for different elements are in the range of 10 to 20%. The method fulfills requirements of precision and sensitivity for specification analysis of nuclear grade beryllium oxide.(Author)

  19. [Effects of beryllium chloride on cultured cells].

    Science.gov (United States)

    Sakaguchi, T; Sakaguchi, S; Nakamura, I; Kagami, M

    1984-05-01

    The effects of beryllium on cultured cells were investigated. Three cell-lines (HeLa-S3, Vero, HEL-R66) were used in these experiments and they were cultured in Eagle's MEM plus 5 or 10% FBS (Fetal Bovine Serum) containing beryllium in various concentrations. HeLa cells or Vero cells were able to grow in the medium with 10 micrograms Be/ml (1.1 mM). On the other hand, the growth of HEL cells were strongly inhibited, even when cultured in the medium with 1 microgram Be/ml (1.1 X 10(-1) mM) and the number of living cells showed markedly low level as compared to that of the control samples cultured in the medium without beryllium. The cytotoxic effects of beryllium on these cells, which were cultured for three days in the medium with beryllium, were observed. None of cytotoxic effects were found on HeLa cells cultured with 0.5 micrograms/ml (5.5 X 10(-2) mM) and on Vero cells cultured with 0.05 micrograms Be/ml (5.5 X 10(-3) mM), while HEL cells received cytotoxic effects even when cultured in the medium containing 0.05 micrograms Be/ml (5.5 X 10(-3) mM), and these effects on the cells appeared strong when cultured in the medium without FBS. It was revealed from these experiments that HEL cells are very sensitive in terms of toxic effects of beryllium. Therefore, there cells can be used for the toxicological study on low level concentrations of the metal.

  20. Mineral resource of the month: beryllium

    Science.gov (United States)

    Shedd, Kim B.

    2006-01-01

    Beryllium metal is lighter than aluminum and stiffer than steel. These and other properties, including its strength, dimensional stability, thermal properties and reflectivity, make it useful for aerospace and defense applications, such as satellite and space-vehicle structural components. Beryllium’s nuclear properties, combined with its low density, make it useful as a neutron reflector and moderator in nuclear reactors. Because it is transparent to most X rays, beryllium is used as X-ray windows in medical, industrial and analytical equipment.

  1. Migration of Beryllium via Multiple Exposure Pathways among Work Processes in Four Different Facilities

    Science.gov (United States)

    Armstrong, Jenna L.; Day, Gregory A.; Park, Ji Young; Stefaniak, Aleksandr B.; Stanton, Marcia L.; Deubner, David C.; Kent, Michael S.; Schuler, Christine R.; Virji, M. Abbas

    2016-01-01

    Inhalation of beryllium is associated with the development of sensitization; however, dermal exposure may also be important. The primary aim of this study was to elucidate relationships among exposure pathways in four different manufacturing and finishing facilities. Secondary aims were to identify jobs with increased levels of beryllium in air, on skin, and on surfaces; identify potential discrepancies in exposure pathways, and determine if these are related to jobs with previously identified risk. Beryllium was measured in air, on cotton gloves, and on work surfaces. Summary statistics were calculated and correlations among all three measurement types were examined at the facility and job level. Exposure ranking strategies were used to identify jobs with higher exposures. The highest air, glove, and surface measurements were observed in beryllium metal production and beryllium oxide ceramics manufacturing jobs that involved hot processes and handling powders. Two finishing and distribution facilities that handle solid alloy products had lower exposures than the primary production facilities, and there were differences observed among jobs. For all facilities combined, strong correlations were found between air-surface (rp ≥ 0.77), glove-surface (rp ≥ 0.76), and air-glove measurements (rp ≥ 0.69). In jobs where higher risk of beryllium sensitization or disease has been reported, exposure levels for all three measurement types were higher than in jobs with lower risk, though they were not the highest. Some jobs with low air concentrations had higher levels of beryllium on glove and surface wipe samples, suggesting a need to further evaluate the causes of the discrepant levels. Although such correlations provide insight on where beryllium is located throughout the workplace, they cannot identify the direction of the pathways between air, surface, or skin. Ranking strategies helped to identify jobs with the highest combined air, glove, and/or surface exposures

  2. Tritium analyses of COBRA-1A2 beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, D.L. [Pacific Northwest National Lab., Richland, WA (United States)

    1998-03-01

    Selected tritium measurements have been completed for the COBRA-1A2 experiment C03 and D03 beryllium pebbles. The completed results, shown in Tables 1, 2, and 3, include the tritium assay results for the 1-mm and 3-mm C03 pebbles, and the 1-mm D03 pebbles, stepped anneal test results for both types of 1-mm pebbles, and the residual analyses for the stepped-anneal specimens. All results have been reported with date-of-count and are not corrected for decay. Stepped-anneal tritium release response is provided in addenda.

  3. Electromagnetic properties of the Beryllium-11 nucleus in Halo EFT

    OpenAIRE

    Hammer H.-W.; Phillips D.R.

    2010-01-01

    We compute electromagnetic properties of the Beryllium-11 nucleus using an effective field theory that exploits the separation of scales in this halo system. We fix the parameters of the EFT from measured data on levels and scattering lengths in the 10Be plus neutron system. We then obtain predictions for the B(E1) strength of the 1/2+ to 1/2− transition in the 11Be nucleus. We also compute the charge radius of the ground state of 11Be. Agreement with experiment within the expected accurac...

  4. Preliminary results for explosion bonding of beryllium to copper

    Energy Technology Data Exchange (ETDEWEB)

    Butler, D.J. [Northwest Technical Industries, Inc., Sequim, WA (United States); Dombrowski, D.E. [Brush Wellman, Inc., Cleveland, OH (United States)

    1995-09-01

    This program was undertaken to determine if explosive bonding is a viable technique for joining beryllium to copper substrates. The effort was a cursory attempt at trying to solve some of the problems associated with explosive bonding beryllium and should not be considered a comprehensive research effort. There are two issues that this program addressed. Can beryllium be explosive bonded to copper substrates and can the bonding take place without shattering the beryllium? Thirteen different explosive bonding iterations were completed using various thicknesses of beryllium that were manufactured with three different techniques.

  5. Vacuum hot-pressed beryllium and TiC dispersion strengthened tungsten alloy developments for ITER and future fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiang, E-mail: xliu@swip.ac.cn [Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, Sichuan (China); Chen, Jiming; Lian, Youyun; Wu, Jihong; Xu, Zengyu; Zhang, Nianman; Wang, Quanming; Duan, Xuro [Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, Sichuan (China); Wang, Zhanhong; Zhong, Jinming [Northwest Rare Metal Material Research Institute, CNMC, Ningxia Orient Group Co. Ltd.,No.119 Yejin Road, Shizuishan City, Ningxia,753000 (China)

    2013-11-15

    Beryllium and tungsten have been selected as the plasma facing materials of the ITER first wall (FW) and divertor chamber, respectively. China, as a participant in ITER, will share the manufacturing tasks of ITER first-wall mockups with the European Union and Russia. Therefore ITER-grade beryllium has been developed in China and a kind of vacuum hot-pressed (VHP) beryllium, CN-G01, was characterized for both physical, and thermo-mechanical properties and high heat flux performance, which indicated an equivalent performance to U.S. grade S-65C beryllium, a reference grade beryllium of ITER. Consequently CN-G01 beryllium has been accepted as the armor material of ITER-FW blankets. In addition, a modification of tungsten by TiC dispersion strengthening was investigated and a W–TiC alloy with TiC content of 0.1 wt.% has been developed. Both surface hardness and recrystallization measurements indicate its re-crystallization temperature approximately at 1773 K. Deuterium retention and thermal desorption behaviors of pure tungsten and the TiC alloy were also measured by deuterium ion irradiation of 1.7 keV energy to the fluence of 0.5–5 × 10{sup 18} D/cm{sup 2}; a main desorption peak at around 573 K was found and no significant difference was observed between pure tungsten and the tungsten alloy. Further characterization of the tungsten alloy is in progress.

  6. Status of beryllium development for fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Billone, M.C. [Argonne National Lab., IL (United States); Donne, M.D. [Kernforschungszentrum Karlsruhe GmbH (Germany). Institut fuer Neutronphysik and Reaktortechnik; Macaulay-Newcombe, R.G. [McMaster Univ., Ontario, CA (United States). Dept. of Engineering Physics

    1994-05-01

    Beryllium is a leading candidate material for the neutron multiplier of tritium breeding blankets and the plasma facing component of first wall and divertor systems. Depending on the application, the fabrication methods proposed include hot-pressing, hot-isostatic-pressing, cold isostatic pressing/sintering, rotary electrode processing and plasma spraying. Product forms include blocks, tubes, pebbles, tiles and coatings. While, in general, beryllium is not a leading structural material candidate, its mechanical performance, as well its performance with regard to sputtering, heat transport, tritium retention/release, helium-induced swelling and chemical compatibility, is an important consideration in first-wall/blanket design. Differential expansion within the beryllium causes internal stresses which may result in cracking, thereby affecting the heat transport and barrier performance of the material. Overall deformation can result in loading of neighboring structural material. Thus, in assessing the performance of beryllium for fusion applications, it is important to have a good database in all of these performance areas, as well as a set of properties correlations and models for the purpose of interpolation/extrapolation.

  7. Potential exposures and risks from beryllium-containing products.

    Science.gov (United States)

    Willis, Henry H; Florig, H Keith

    2002-10-01

    Beryllium is the strongest of the lightweight metals. Used primarily in military applications prior to the end of the Cold War, beryllium is finding new applications in many commercial products, including computers, telecommunication equipment, and consumer and automotive electronics. The use of beryllium in nondefense consumer applications is of concern because beryllium is toxic. Inhalation of beryllium dust or vapor causes a chronic lung disease in some individuals at concentrations as low as 0.01 microg/m3 in air. As beryllium enters wider commerce, it is prudent to ask what risks this might present to the general public and to workers downstream of the beryllium materials industry. We address this question by evaluating the potential for beryllium exposure from the manufacturing, use, recycle, and disposal of beryllium-containing products. Combining a market study with a qualitative exposure analysis, we determine which beryllium applications and life cycle phases have the largest exposure potential. Our analysis suggests that use and maintenance of the most common types of beryllium-containing products do not result in any obvious exposures of concern, and that maintenance activities result in greater exposures than product use. Product disposal has potential to present significant individual risks, but uncertainties concerning current and future routes of product disposal make it difficult to be definitive. Overall, additional exposure and dose-response data are needed to evaluate both the health significance of many exposure scenarios, and the adequacy of existing regulations to protect workers and the public. Although public exposures to beryllium and public awareness and concern regarding beryllium risks are currently low, beryllium risks have psychometric qualities that may lead to rapidly heightened public concern. PMID:12442995

  8. A NEAR REAL-TIME BERYLLIUM MONITOR WITH CAM AND WIPE ANALYSIS CAPABILITIES

    Energy Technology Data Exchange (ETDEWEB)

    D.T. Kendrick; Steven Saggese

    2002-12-01

    Science & Engineering Associates, Inc. (SEA), under contract No. DE-AC26-00NT40768, was tasked by the US Department of Energy--National Energy Technology Laboratory to develop and test a near real-time beryllium monitor for airborne and surface measurements. Recent public awareness of the health risks associated with exposure to beryllium has underscored the need for better, faster beryllium monitoring capabilities within the DOE. A near real-time beryllium monitor will offer significant improvements over the baseline monitoring technology currently in use. Whereas the baseline technology relies upon collecting an air sample on a filter and the subsequent analysis of the filter by an analytical laboratory, this effort developed a monitor that offers near real-time measurement results while work is in progress. Since the baseline typically only offers after-the-fact documentation of exposure levels, the near real-time capability provides a significant increase in worker protection. The beryllium monitor developed utilizes laser induced breakdown spectroscopy, or LIBS as the fundamental measurement technology. LIBS has been used in a variety of laboratory and field based instrumentation to provide real-time, and near-real-time elemental analysis capabilities. LIBS is an analytical technique where a pulsed high energy laser beam is focused to a point on the sample to be interrogated. The high energy density produces a small high temperature plasma plume, sometimes called a spark. The conditions within this plasma plume result in the constituent atoms becoming excited and emitting their characteristic optical emissions. The emission light is collected and routed to an optical spectrometer for quantitative spectral analysis. Each element has optical emissions, or lines, of a specific wavelength that can be used to uniquely identify that element. In this application, the intensity of the beryllium emission is used to provide a quantitative measure of the abundance of the

  9. Detection of beryllium treatment of natural sapphires by NRA

    Science.gov (United States)

    Gutiérrez, P. C.; Ynsa, M.-D.; Climent-Font, A.; Calligaro, T.

    2010-06-01

    Since the 1990's, artificial treatment of natural sapphires (Al 2O 3 crystals coloured by impurities) by diffusion of beryllium at high temperature has become a growing practice. This process permits to enhance the colour of these gemstones, and thus to increase their value. Detection of such a treatment - diffusion of tens of μg/g of beryllium in Al 2O 3 crystals - is usually achieved using high sensitivity techniques like laser-ablation inductively coupled plasma mass spectrometry (LA-ICP/MS) or laser-induced breakdown spectrometry (LIBS) which are unfortunately micro-destructive (leaving 50-100-μm diameter craters on the gems). The simple and non-destructive alternative method proposed in this work is based on the nuclear reaction 9Be(α, nγ) 12C with an external helium ion beam impinging on the gem directly placed in air. The 4439 keV prompt γ-ray tagging Be atoms are detected with a high efficiency bismuth germanate scintillator. Beam dose is monitored using the 2235 keV prompt γ-ray produced during irradiation by the aluminium of the sapphire matrix through the 27Al(α, pγ) 30Si nuclear reaction. The method is tested on a series of Be-treated sapphires previously analyzed by LA-ICP/MS to determine the optimal conditions to obtain a peak to background appropriate to reach the required μg/g sensitivity. Using a 2.8-MeV external He beam and a beam dose of 200 μC, beryllium concentrations from 5 to 16 μg/g have been measured in the samples, with a detection limit of 1 μg/g.

  10. Detection of beryllium treatment of natural sapphires by NRA

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, P.C., E-mail: carolina.gutierrez@uam.e [Centro de Micro-Analisis de Materiales (CMAM), Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Ynsa, M.-D.; Climent-Font, A. [Centro de Micro-Analisis de Materiales (CMAM), Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Dpto. Fisica Aplicada C-12, Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Calligaro, T. [Centre de Recherche et de Restauration des musees de France C2RMF, CNRS-UMR171, 14 quai Francois Mitterrand, 75001 Paris (France)

    2010-06-15

    Since the 1990's, artificial treatment of natural sapphires (Al{sub 2}O{sub 3} crystals coloured by impurities) by diffusion of beryllium at high temperature has become a growing practice. This process permits to enhance the colour of these gemstones, and thus to increase their value. Detection of such a treatment - diffusion of tens of {mu}g/g of beryllium in Al{sub 2}O{sub 3} crystals - is usually achieved using high sensitivity techniques like laser-ablation inductively coupled plasma mass spectrometry (LA-ICP/MS) or laser-induced breakdown spectrometry (LIBS) which are unfortunately micro-destructive (leaving 50-100-{mu}m diameter craters on the gems). The simple and non-destructive alternative method proposed in this work is based on the nuclear reaction {sup 9}Be({alpha}, n{gamma}){sup 12}C with an external helium ion beam impinging on the gem directly placed in air. The 4439 keV prompt {gamma}-ray tagging Be atoms are detected with a high efficiency bismuth germanate scintillator. Beam dose is monitored using the 2235 keV prompt {gamma}-ray produced during irradiation by the aluminium of the sapphire matrix through the {sup 27}Al({alpha}, p{gamma}){sup 30}Si nuclear reaction. The method is tested on a series of Be-treated sapphires previously analyzed by LA-ICP/MS to determine the optimal conditions to obtain a peak to background appropriate to reach the required {mu}g/g sensitivity. Using a 2.8-MeV external He beam and a beam dose of 200 {mu}C, beryllium concentrations from 5 to 16 {mu}g/g have been measured in the samples, with a detection limit of 1 {mu}g/g.

  11. Model study in chemisorption: atomic hydrogen on beryllium clusters

    Energy Technology Data Exchange (ETDEWEB)

    Bauschlicher, C.W. Jr.

    1976-08-01

    The interaction between atomic hydrogen and the (0001) surface of Be metal has been studied by ab initio electronic structure theory. Self-consistent-field (SCF) calculations have been performed using minimum, optimized minimum, double zeta and mixed basis sets for clusters as large as 22 Be atoms. The binding energy and equilibrium geometry (the distance to the surface) were determined for 4 sites. Both spatially restricted (the wavefunction was constrained to transform as one of the irreducible representations of the molecular point group) and unrestricted SCF calculations were performed. Using only the optimized minimum basis set, clusters containing as many as 22 beryllium atoms have been investigated. From a variety of considerations, this cluster is seen to be nearly converged within the model used, providing the most reliable results for chemisorption. The site dependence of the frequency is shown to be a geometrical effect depending on the number and angle of the bonds. The diffusion of atomic hydrogen through a perfect beryllium crystal is predicted to be energetically unfavorable. The cohesive energy, the ionization energy and the singlet-triplet separation were computed for the clusters without hydrogen. These quantities can be seen as a measure of the total amount of edge effects. The chemisorptive properties are not related to the total amount of edge effects, but rather the edge effects felt by the adsorbate bonding berylliums. This lack of correlation with the total edge effects illustrates the local nature of the bonding, further strengthening the cluster model for chemisorption. A detailed discussion of the bonding and electronic structure is included. The remaining edge effects for the Be/sub 22/ cluster are discussed.

  12. Thermal ramp tritium release in COBRA-1A2 C03 beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, D.L. [Pacific Northwest National Lab., Richland, WA (United States)

    1998-03-01

    Tritium release kinetics, using the method of thermal ramp heating at three linear ramp rates, were measured on the COBRA-1A2 C03 1-mm beryllium pebbles. This report includes a brief discussion of the test, and the test data in graph format.

  13. Experimental bremsstrahlung yields for MeV proton bombardment of beryllium and carbon

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, David D. [Institute for Environmental Research, Australian Nuclear Science and Technology Organisation, Private Mail Bag 1, Menai, NSW 2234 (Australia)], E-mail: dcz@ansto.gov.au; Stelcer, Eduard; Siegele, Rainer; Ionescu, Mihail; Prior, Michael [Institute for Environmental Research, Australian Nuclear Science and Technology Organisation, Private Mail Bag 1, Menai, NSW 2234 (Australia)

    2008-04-15

    Experimental bremsstrahlung yields for 2, 3 and 4 MeV protons on thin beryllium and carbon targets have been measured. The yields have been corrected for detector efficiency, self-absorption in the target and fitted to 9th order polynomials over the X-ray energy range 1-10 keV for easy comparison with theoretical calculations.

  14. Physical theory of measuring process : a critical review

    OpenAIRE

    榛葉, 豊; 福地, 充; 坂田, 亮

    1980-01-01

    After a survey of the orthodox interpretation of quantum mechanics and von Neumann's approach to a measurement theory, the measurement theory of Daneri, Loinger and Prosperi is critically reviewed in regard in particular to their aims and assumptions. The review will lead us to see what is still desirable of a physical theory of measurement on quantum mechanical systems.

  15. Steam chemical reactivity of plasma-sprayed beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Anderl, R.A.; Pawelko, R.J.; Smolik, G.R. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States). Idaho National Engineering and Environmental Lab.; Castro, R.G. [Los Alamos National Lab., NM (United States)

    1998-07-01

    Plasma-spraying with the potential for in-situ repair makes beryllium a primary candidate for plasma facing and structural components in experimental magnetic fusion machines. Deposits with good thermal conductivity and resistance to thermal cycling have been produced with low pressure plasma-spraying (LPPS). A concern during a potential accident with steam ingress is the amount of hydrogen produced by the reactions of steam with hot components. In this study the authors measure the reaction rates of various deposits produced by LPPS with steam from 350 C to above 1,000 C. They correlate these reaction rates with measurements of density, open porosity and BET surface areas. They find the reactivity to be largely dependent upon effective surface area. Promising results were obtained below 600 C from a 94% theoretical dense (TD) deposit with a BET specific surface area of 0.085 m{sup 2}/g. Although reaction rates were higher than those for dense consolidated beryllium they were substantially lower, i.e., about two orders of magnitude, than those obtained from previously tested lower density plasma-sprayed deposits.

  16. Control of beryllium powder at a DOE facility

    International Nuclear Information System (INIS)

    Beryllium is contained in a number of domestic and national defense items. Although many items might contain beryllium in some manner, few people need worry about the adverse effects caused by exposure to beryllium because it is the inhalable form of beryllium that is most toxic. Chronic beryllium disease (CBD), a granulomas and fibrotic lung disease with long latency, can be developed after inhalation exposures to beryllium. It is a progressive, debilitating lung disease. Its occurrence in those exposed to beryllium has been difficult to predict because some people seem to react to low concentration exposures whereas others do not react to high concentration exposures. Onset of the disease frequently occurs between 15 to 20 years after exposure begins. Some people develop the disease after many years of low concentration exposures but others do not develop CBD even though beryllium is shown to be present in lungs and urine. Conclusions based on these experiences are that their is some immunological dependence of developing CBD in about 3--4% of the exposed population, but the exact mechanism involved has not yet been identified. Acute beryllium disease can occur after a single exposure to a concentration of greater than 0.100 mg/m3 (inhalation exposure); it is characterized by the development of chemical pneumoconiosis, a respiratory disease. The acute effect of skin contact is a dermatitis characterized by itching and reddened, elevated, or fluid-accumulated lesions which appear particularly on the exposed surfaces of the body, especially the face, neck, arms, and hands. Small particles of beryllium that enter breaks in the skin can lead to the development of granulomas and/or open sores that do not heal until the beryllium has been removed. Our interest is only airborne beryllium, which is found in areas that machine or produce beryllium

  17. Use of a Paraffin Based Grout to Stabilize Buried Beryllium and Other Wastes

    International Nuclear Information System (INIS)

    The long term durability of WAXFIXi, a paraffin based grout, was evaluated for in situ grouting of activated beryllium wastes in the Subsurface Disposal Area (SDA), a radioactive landfill at the Radioactive Waste Management Complex, part of the Idaho National Laboratory (INL). The evaluation considered radiological and biological mechanisms that could degrade the grout using data from an extensive literature search and previous tests of in situ grouting at the INL. Conservative radioactive doses for WAXFIX were calculated from the ''hottest'' (i.e., highest-activity) Advanced Test Reactor beryllium block in the SDA.. These results indicate that WAXFIX would not experience extensive radiation damage for many hundreds of years. Calculation of radiation induced hydrogen generation in WAXFIX indicated that grout physical performance should not be reduced beyond the effects of radiation dose on the molecular structure. Degradation of a paraffin-based grout by microorganisms in the SDA is possible and perhaps likely, but the rate of degradation will be at a slower rate than found in the literature reviewed. The calculations showed the outer 0.46 m (18 in.) layer of each monolith, which represents the minimum expected distance to the beryllium block, was calculated to require 1,000 to 3,600 years to be consumed. The existing data and estimations of biodegradation and radiolysis rates for WAXFIX/paraffin do not indicate any immediate problems with the use of WAXFIX for grouting beryllium or other wastes in the SDA

  18. The use of a beryllium Hopkinson bar to characterize in-axis and cross-axis accelerometer response in shock environments

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, V.I.; Brown, F.A.

    1997-05-01

    The characteristics of a piezoresistive accelerometer in shock environments are being studied at Sandia National Laboratories in the Mechanical Shock Testing Laboratory. A beryllium Hopkinson bar capability has been developed to extend the understanding of the piezoresistive accelerometer, in two mechanical configurations and with and without mechanical isolation, in the high frequency, high shock environments where measurements are being made. In this paper, recent measurements with beryllium single and split-Hopkinson bar configurations are described. The in axis performance of the piezoresistive accelerometer in mechanical isolation for frequencies of dc-30 kHz and shock magnitudes of up to 6,000 g as determined from measurements with a beryllium Hopkinson bar with a certified laser doppler vibrometer as the reference measurement are presented. Results of characterizations of the accelerometers subjected to cross axis shocks in a split beryllium Hopkinson bar configuration are also presented.

  19. Beryllium-10 in the Taylor Dome ice core: Applications to Antarctic glaciology and paleoclimatology

    Energy Technology Data Exchange (ETDEWEB)

    Steig, E.J.

    1996-12-31

    An ice core was drilled at Taylor dome, East Antarctica, reaching to bedrock at 554 meters. Oxygen-isotope measurements reveal climatic fluctuations through the last interglacial period. To facilitate comparison of the Taylor Dome paleoclimate record with geologic data and results from other deep ice cores, several glaciological issues need to be addressed. In particular, accumulation data are necessary as input for numerical ice-flow-models, for determining the flux of chemical constituents from measured concentrations, and for calculation of the offset in age between ice and trapped air in the core. The analysis of cosmogenic beryllium-10 provides a geochemical method for constraining the accumulation-rate history at Taylor Dome. High-resolution measurements were made in shallow firn cores and snow pits to determine the relationship among beryllium-10 concentrations, wet and dry deposition mechanisms, and snow-accumulation rates. Comparison between theoretical and measured variations in deposition over the last 75 years constrains the relationship between beryllium-10 deposition and global average production rates. The results indicate that variations in geomagnetically-modulated production-rate do not strongly influence beryllium-10 deposition at Taylor Dome. Although solar modulation of production rate is important for time scales of years to centuries, snow-accumulation rate is the dominant control on ice-core beryllium-10 concentrations for longer periods. Results show that the Taylor Dome core can be used to provide new constraints on regional climate over the last 130,000 years, complementing the terrestrial and marine geological record from the Dry Valley, Transantarctic Mountains and western Ross Sea.

  20. Helium analyses of 1-mm beryllium microspheres from COBRA-1A2

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, B.M. [Pacific Northwest National Lab., Richland, WA (United States)

    1998-03-01

    Multiple helium analyses on four beryllium microspheres irradiated in the Experimental Breeder Reactor-II (EBR-II) at Argonne National Laboratory-West (ANL-W), are reported. The purpose of the analyses was to determine the total helium content of the beryllium, and to determine the helium release characteristics of the beryllium as a function of time and temperature. For the helium release measurements, sequential helium analyses were conducted on two of the samples over a temperature range from 500 C to 1100 C in 100 C increments. Total helium measurements were conducted separately using the normal analysis method of vaporizing the material in a single analysis run. Observed helium release in the two beryllium samples was nonlinear with time at each temperature interval, with each step being characterized by a rather rapid initial release rate, followed by a gradual slowing of the rate over time. Sample Be-C03-1 released virtually all of its helium after approximately 30 minutes at 1000 C, reaching a final value of 2722 appm. Sample Be-D03-1, on the other hand, released only about 62% of its helium after about 1 hour at 1100 c, reaching a final value of 1519 appm. Combining these results with subsequent vaporization runs on the two samples, yielded total helium concentrations of 2724 and 2459 appm. Corresponding helium concentrations measured in the two other C03 and D03 samples, by vaporization alone, were 2941 and 2574 appm. Both sets of concentrations are in reasonable agreement with predicted values of 2723 and 2662 appm. Helium-3 levels measured during the latter two vaporization runs were 2.80 appm for Be-C03-2, and 2.62 appm for Be-D03-2. Calculated {sup 3}He values are slightly lower at 2.55 and 2.50 appm, respectively, suggesting somewhat higher tritium levels in the beryllium than predicted.

  1. REVIEW OF ENVIRONMENTAL APPLICATIONS OF BIOLUMINESCENCE MEASUREMENTS

    Science.gov (United States)

    This review of the recent literature on environmental applications of bioluminescence systems will focus on in vivo and in vitro bioluminescence methods that have been utilized to elucidate properties of chemicals, toxic and mutagenic effects, and to estimate biomass. he unifying...

  2. Review of measures to control radiation

    International Nuclear Information System (INIS)

    Methods used in Canada and the U.S.A. to overcome problems in the control of radiation, to prescribe standards and to ensure that compliance with the standards is achieved are reviewed. The relevant Acts and Regulations are outlined. Options which could be applied in Australia for effecting better control of radiation are suggested

  3. Status of material development for lifetime expansion of beryllium reflector

    International Nuclear Information System (INIS)

    Beryllium has been used as the reflector element material in the reactor, specifically S-200F structural grade beryllium manufactured by Materion Brush Beryllium and Composites (former, Brush Wellman Inc.). As a part of the reactor upgrade, the Japan Atomic Energy Agency (JAEA) also has carried out the cooperation experiments to extend the operating lifetime of the beryllium reflector elements. It will first be necessary to determine which of the material's physical, mechanical and chemical properties will be the most influential on that choice. The irradiation testing plans to evaluate the various beryllium grades are also briefly considered and prepared. In this paper, material selection, irradiation test plan and PEI development for lifetime expansion of beryllium are described for material testing reactors. (author)

  4. Mechanisms of hydrogen retention in metallic beryllium and beryllium oxide and properties of ion-induced beryllium nitride; Rueckhaltemechanismen fuer Wasserstoff in metallischem Beryllium und Berylliumoxid sowie Eigenschaften von ioneninduziertem Berylliumnitrid

    Energy Technology Data Exchange (ETDEWEB)

    Oberkofler, Martin

    2011-09-22

    In the framework of this thesis laboratory experiments on atomically clean beryllium surfaces were performed. They aim at a basic understanding of the mechanisms occurring upon interaction of a fusion plasma with a beryllium first wall. The retention and the temperature dependent release of implanted deuterium ions are investigated. An atomistic description is developed through simulations and through the comparison with calculations based on density functional theory. The results of these investigations are compared to the behaviour of hydrogen upon implantation into thermally grown beryllium oxide layers. Furthermore, beryllium nitride is produced by implantation of nitrogen into metallic beryllium and its properties are investigated. The results are interpreted with regard to the use of beryllium in a fusion reactor. (orig.)

  5. Characterization of plasma sprayed beryllium ITER first wall mockups

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R.G.; Vaidya, R.U.; Hollis, K.J. [Los Alamos National Lab., NM (United States). Material Science and Technology Div.

    1998-01-01

    ITER first wall beryllium mockups, which were fabricated by vacuum plasma spraying the beryllium armor, have survived 3000 thermal fatigue cycles at 1 MW/m{sup 2} without damage during high heat flux testing at the Plasma Materials Test Facility at Sandia National Laboratory in New Mexico. The thermal and mechanical properties of the plasma sprayed beryllium armor have been characterized. Results are reported on the chemical composition of the beryllium armor in the as-deposited condition, the through thickness and normal to the through thickness thermal conductivity and thermal expansion, the four-point bend flexure strength and edge-notch fracture toughness of the beryllium armor, the bond strength between the beryllium armor and the underlying heat sink material, and ultrasonic C-scans of the Be/heat sink interface. (author)

  6. Late-time radiography of beryllium ignition-target ablators in long-pulse gas-filled hohlraums

    International Nuclear Information System (INIS)

    A multiple-laboratory campaign is underway to qualify beryllium as a fusion capsule ablator for the National Ignition Facility [Moses and Wuest, Fusion Sci. Technol. 43, 420 (2003)]. Although beryllium has many advantages over other ablator materials, individual crystals of beryllium have anisotropic properties, e.g., sound speed, elastic constants, and thermal expansion coefficients, which may seed hydrodynamic instabilities during the implosion phase of ignition experiments. Experiments based on modeling have begun at the OMEGA laser [Boehly, McCrory, Verdon et al., Fusion Eng. Design 44, 35 (1999)] to create a test bed for measuring instability growth rates with face-on radiography of perturbed beryllium samples with the goal of establishing a specification for microstructure in beryllium used as an ablator. The specification would include the size and distribution of sizes of grains and voids and the impurity content. The experimental platform is a 4 kJ laser-heated (for ∼6 ns) hohlraum that is well modeled for radiation temperature and for shock pressure and breakout timing through the driven beryllium sample. A 1 atm methane gas fill has been used to maintain a clear line of sight through the hohlraum for radiography with acceptable plasma backscatter losses. The peak radiation temperature is 145 eV; the pressure early in the laser pulse is 1 Mbar for over 1 ns. Radiographs of sinusoidally perturbed copper-doped (0.9% by atom) beryllium samples have been obtained more than 10 ns after drive initiation. With the current laser drive, a growth factor approaching ten has been measured for initial 2.5 μm perturbations with on-axis radiography

  7. Dynamic behaviour of S200F beryllium

    International Nuclear Information System (INIS)

    Compression tests have been made on a large scale of strain, strain rate (up to 2000 s-1) and temperature (between 20 C and 300 C). From these experiences, we have calculated a constitutive model for beryllium S200F, which can be used by computer codes. Its formulation is not far from Steinberg, Cochran and Guinan's. But in our case, the influences of temperature and strain rate appear clearly within the expression. To validate our equation, we have used it in a computer code. Its extrapolation for higher strain rates is in good agreement with experiments such as Taylor impact tests or plate impact tests (strain rates greater than 104 s-1). With micrography, we could settle a link between the main strain mode within the material, and the variation of one parameter of the model. Beside the constitutive model, we have shown that shock loaded beryllium behaves in two different ways. If the strain rate is lower than 5.106 s-1, then it is proportional to the squared shock pressure. Beyond, it is a linear function of shock pressure to the power of four. By a spall study on beryllium, we have confirmed that it is excessively fragile. Its fracture is sudden, at a strength near 1 GPa. (author)

  8. Interaction of nitrogen ions with beryllium surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Dobes, Katharina [Institute of Applied Physics, TU Wien, Association EURATOM ÖAW, Vienna (Austria); Köppen, Martin [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Oberkofler, Martin [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, D-85748 Garching (Germany); Lungu, Cristian P.; Porosnicu, Corneliu [National Institute for Laser, Plasma, and Radiation Physics, Bucharest (Romania); Höschen, Till; Meisl, Gerd [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, D-85748 Garching (Germany); Linsmeier, Christian [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Aumayr, Friedrich, E-mail: aumayr@iap.tuwien.ac.at [Institute of Applied Physics, TU Wien, Association EURATOM ÖAW, Vienna (Austria)

    2014-12-01

    The interaction of energetic nitrogen projectiles with a beryllium surface is studied using a highly sensitive quartz crystal microbalance technique. The overall mass change rate of the beryllium sample under N{sub 2}{sup +} ion impact at an ion energy of 5000 eV (i.e. 2500 eV per N) is investigated in situ and in real-time. A strong dependency of the observed mass change rate on the nitrogen fluence (at constant flux) is found and can be attributed to the formation of a nitrogen-containing mixed material layer within the ion penetration depth. The presented data elucidate the dynamics of the interaction process and the surface saturation with increasing nitrogen fluence in a unique way. Basically, distinct interaction regimes can be discriminated, which can be linked to the evolution of the surface composition upon nitrogen impact. Steady state surface conditions are obtained at a total cumulative nitrogen fluence of ∼80 × 10{sup 16} N atoms per cm{sup 2}. In dynamic equilibrium, the interaction is marked by continuous surface erosion. In this case, the observed total sputtering yield becomes independent from the applied nitrogen fluence and is of the order of 0.4 beryllium atoms per impinging nitrogen atom.

  9. Aerosol resuspension from fabric: implications for personal monitoring in the beryllium industry.

    Science.gov (United States)

    Bohne, J E; Cohen, B S

    1985-02-01

    The fabric used for work clothing at an industrial site can significantly influence personal monitor (PM) exposure estimates because dust resuspension from clothing can increase the concentration at the sampler inlet. The magnitude of the effect depends on removal forces and on the interaction of the contaminant particles with work garments. Aerosol deposition and resuspension on cotton and Nomex aramid fabrics was evaluated at a beryllium refinery. Electrostatically charged cotton backdrops collected more beryllium than neutral controls, but electronegative Nomex backdrops did not. Moving fabrics collected more beryllium than did stationary controls. When contaminated fabrics were agitated, PMs mounted 2.5 cm in front of the fabric collected more beryllium than monitors above the fabric, positioned to simulate the nose or mouth. The difference between the air concentrations measured by these PMs increased with Be loading and tended to level off for highly contaminated fabric. Cotton resuspended a larger fraction of its contaminant load than Nomex. These results are consistent with current knowledge of the behavior of particles on fabric fibers. Aerosol resuspension from garments is an important consideration in assessing inhalation exposure to toxic dusts. A garment may attract and retain toxic particles. This contamination is then available for later resuspension. PMID:3976498

  10. The relationship between gross and net erosion of beryllium at elevated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Doerner, R.P., E-mail: rdoerner@ucsd.edu [Center for Energy Research, University of California in San Diego, La Jolla, CA 92093-0417 (United States); Jepu, I. [National Institute for Lasers, Plasma and Radiation Physics, NILPRP, Magurele, Bucharest 077125 (Romania); Nishijima, D. [Center for Energy Research, University of California in San Diego, La Jolla, CA 92093-0417 (United States); Safi, E.; Bukonte, L.; Lasa, A.; Nordlund, K. [Association EURATOM-Tekes, University of Helsinki, PO Box 43, 00014 University of Helsinki (Finland); Schwarz-Selinger, T. [Max-Planck Institut für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany)

    2015-08-15

    Surface temperature is a critical variable governing plasma–material interactions. PISCES-B injects controllable amounts of Be impurities into the plasma to balance, or exceed, the erosion rate of beryllium from samples in un-seeded plasma exposures. At low temperature, an order of magnitude more beryllium, than the beryllium mass loss measured in un-seeded discharges, needs to be seeded into the plasma to achieve no mass loss from a sample. At elevated temperature, no mass loss is achieved when the beryllium-seeding rate equals the mass loss rate in un-seeded discharges. Molecular dynamics simulations show that below 500 K, Be adatoms have difficulty surmounting the Ehrlich–Schwoebel barrier at the edge of a terrace. Above this temperature, an Arrhenius behavior is observed with an activation energy of 0.32 eV. Qualitatively, this indicates that at low surface temperature the deposited atoms may be more easily re-eroded, accounting for the increased seeding needed to balance the erosion.

  11. Beryllium-steam interaction experiments and self-sustained reaction studies (integral validation testing)

    International Nuclear Information System (INIS)

    In accordance with the Task Agreement G 81 TT 02 FR, Be-steam interaction experiments were performed in order to obtain experimental data for validation of calculation codes analyzing accident situation involving water coolant ingress into the vacuum chamber of International Thermonuclear Experimental Reactor (ITER). The report describes the experimental facility, specimens used for oxidized beryllium emissivity factor determination and the ITER first wall mock-up used in the experiments on its interaction with steam. Experimental results on Be-emissivity factor after beryllium oxidation versus temperature are given. Four experimental runs of the ITER first wall mock-up interaction with steam were carried out for initial conditions when internal (beryllium) mock-up layer was heated to temperatures of 680, 880 and 1273 K and steam temperature was of 413-423 K. The plots of temperature evolution for beryllium, bronze and stainless steel layers versus time were obtained. Temperature records with 5 s interval are presented. Hydrogen gain in these four experimental runs was measured. The data may be used for computer code validation. No self-sustained Be-steam chemical reaction at temperatures used in the experiments was observed

  12. An investigation of process sensitivity for electron beam evaporation of beryllium

    International Nuclear Information System (INIS)

    This paper reports on the process sensitivity of a beryllium coating process investigated using a statistical design of experiments approach. Process sensitivity is a measure of the variation in a given quality characteristic of the coating as a function of the evaporation process parameters. Manufacturing processes which maximize quality while simultaneously minimizing variability are most desirable. Three evaporation process parameters were included in this study: deposition rate, substrate temperature, and run time. A central composite experimental design employing a total of 18 coating runs was used to produce beryllium coatings on aluminum, silicon, fused silica, and beryllium substrates. The quality of the resulting coatings was characterized by scanning electron microscopy, IR spectrophotometry, stylus profilometry, and weight gain (thickness). Analysis of these results allowed the development of functional relationship between the quality characteristics (thickness, reflectance, etc.) and the evaporation process parameters. Process sensitivity for each response was then determined by calculating the gradient of each quality characteristic with respect to all three process parameters. Three dimensional plots were developed of the quality characteristic and its process sensitivity as a function of process parameters. Both quality characteristic and process sensitivity plots will be presented and discussed. For many of the quality characteristics, temperature during deposition was found to be the most sensitive process parameter for the beryllium c-beam evaporation process

  13. Review of air flow measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, Jennifer

    2002-12-01

    Airflow measurement techniques are necessary to determine the most basic of indoor air quality questions: ''Is there enough fresh air to provide a healthy environment for the occupants of the building?'' This paper outlines airflow measurement techniques, but it does not make recommendations for techniques that should be used. The airflows that will be discussed are those within a room or zone, those between rooms or zones, such as through doorways (open or closed) or passive vents, those between the building and outdoors, and those through mechanical air distribution systems. Techniques that are highlighted include particle streak velocimetry, hot wire anemometry, fan pressurization (measuring flow at a given pressure), tracer gas, acoustic methods for leak size determination, the Delta Q test to determine duct leakage flows, and flow hood measurements. Because tracer gas techniques are widely used to measure airflow, this topic is broken down into sections as follows: decay, pulse injection, constant injection, constant concentration, passive sampling, and single and multiple gas measurements for multiple zones.

  14. Flow measurement in mechanical ventilation: a review.

    Science.gov (United States)

    Schena, Emiliano; Massaroni, Carlo; Saccomandi, Paola; Cecchini, Stefano

    2015-03-01

    Accurate monitoring of flow rate and volume exchanges is essential to minimize ventilator-induced lung injury. Mechanical ventilators employ flowmeters to estimate the amount of gases delivered to patients and use the flow signal as a feedback to adjust the desired amount of gas to be delivered. Since flowmeters play a crucial role in this field, they are required to fulfill strict criteria in terms of dynamic and static characteristics. Therefore, mechanical ventilators are equipped with only the following kinds of flowmeters: linear pneumotachographs, fixed and variable orifice meters, hot wire anemometers, and ultrasonic flowmeters. This paper provides an overview of these sensors. Their working principles are described together with their relevant advantages and disadvantages. Furthermore, the most promising emerging approaches for flowmeters design (i.e., fiber optic technology and three dimensional micro-fabrication) are briefly reviewed showing their potential for this application. PMID:25659299

  15. Review of SQUID Sensors for Measuring Magnetocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. H.; Kim, J. M.; Yu, K. K.; Kim, K.; Kwon, H. [Brain and Cognition Measurement Lab, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2011-08-15

    Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

  16. Measures of Cultural Competence in Nurses: An Integrative Review

    OpenAIRE

    Collette Loftin; Vicki Hartin; Marietta Branson; Helen Reyes

    2013-01-01

    Background. There is limited literature available identifying and describing the instruments that measure cultural competence in nursing students and nursing professionals. Design. An integrative review was undertaken to identify the characteristics common to these instruments, examine their psychometric properties, and identify the concepts these instruments are designed to measure. Method. There were eleven instruments identified that measure cultural competence in nursing. Of these eleven ...

  17. Electrophysiological measurements of spectral sensitivities: a review

    Directory of Open Access Journals (Sweden)

    R.D. DeVoe

    1997-02-01

    Full Text Available Spectral sensitivities of visual systems are specified as the reciprocals of the intensities of light (quantum fluxes needed at each wavelength to elicit the same criterion amplitude of responses. This review primarily considers the methods that have been developed for electrophysiological determinations of criterion amplitudes of slow-wave responses from single retinal cells. Traditional flash methods can require tedious dark adaptations and may yield erroneous spectral sensitivity curves which are not seen in such modifications as ramp methods. Linear response methods involve interferometry, while constant response methods involve manual or automatic adjustments of continuous illumination to keep response amplitudes constant during spectral scans. In DC or AC computerized constant response methods, feedback to determine intensities at each wavelength is derived from the response amplitudes themselves. Although all but traditional flash methods have greater or lesser abilities to provide on-line determinations of spectral sensitivities, computerized constant response methods are the most satisfactory due to flexibility, speed and maintenance of a constant adaptation level

  18. Irradiated Beryllium Disposal Workshop, Idaho Falls, ID, May 29-30, 2002

    Energy Technology Data Exchange (ETDEWEB)

    Longhurst, Glen Reed; Anderson, Gail; Mullen, Carlan K; West, William Howard

    2002-07-01

    In 2001, while performing routine radioactive decay heat rate calculations for beryllium reflector blocks for the Advanced Test Reactor (ATR), it became evident that there may be sufficient concentrations of transuranic isotopes to require classification of this irradiated beryllium as transuranic waste. Measurements on samples from ATR reflector blocks and further calculations confirmed that for reflector blocks and outer shim control cylinders now in the ATR canal, transuranic activities are about five times the threshold for classification. That situation implies that there is no apparent disposal pathway for this material. The problem is not unique to the ATR. The High Flux Isotope Reactor at Oak Ridge National Laboratory, the Missouri University Research Reactor at Columbia, Missouri and other reactors abroad must also deal with this issue. A workshop was held in Idaho Falls Idaho on May 29-30, 2002 to acquaint stakeholders with these findings and consider a path forward in resolving the issues attendant to disposition of irradiated material. Among the findings from this workshop were (1) there is a real potential for the US to be dependent on foreign sources for metallic beryllium within about a decade; (2) there is a need for a national policy on beryllium utilization and disposition and for a beryllium coordinating committee to be assembled to provide guidance on that policy; (3) it appears it will be difficult to dispose of this material at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico due to issues of Defense classification, facility radioactivity inventory limits, and transportation to WIPP; (4) there is a need for a funded DOE program to seek resolution of these issues including research on processing techniques that may make this waste acceptable in an existing disposal pathway or allow for its recycle.

  19. First beryllium capsule implosions on the National Ignition Facility

    Science.gov (United States)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B.; Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F.; Haan, S. W.; Celliers, P. M.; Clark, D. S.; Hammel, B. A.; Kozioziemski, B.; Schneider, M. B.; Marinak, M. M.; Rinderknecht, H. G.; Robey, H. F.; Salmonson, J. D.; Patel, P. K.; Ma, T.; Edwards, M. J.; Stadermann, M.; Baxamusa, S.; Alford, C.; Wang, M.; Nikroo, A.; Rice, N.; Hoover, D.; Youngblood, K. P.; Xu, H.; Huang, H.; Sio, H.

    2016-05-01

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  20. Physical properties of beryllium oxide - Irradiation effects; Proprietes physiques et caracteristiques mecaniques de l'oxyde de beryllium fritte - Effet de l'irradiation et guerison

    Energy Technology Data Exchange (ETDEWEB)

    Elston, J.; Caillat, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This work has been carried out in view of determining several physical properties of hot-pressed beryllium oxide under various conditions and the change of these properties after irradiation. Special attention has been paid on to the measurement of the thermal conductivity coefficient and thermal diffusivity coefficient. Several designs for the measurement of the thermal conductivity coefficient have been achieved. They permit its determination between 50 and 300 deg. C, between 400 and 800 deg. C. Some measurements have been made above 1000 deg. C. In order to measure the thermal diffusivity coefficient, we heat a perfectly flat surface of a sample in such a way that the heat flux is modulated (amplitude and frequency being adjustable). The thermal diffusivity coefficient is deduced from the variations of temperature observed on several spots. Tensile strength; compressive strength; expansion coefficient; sound velocity and crystal parameters have been also measured. Some of the measurements have been carried out after neutron irradiation. Some data have been obtained on the change of the properties of beryllium oxide depending on the integrated neutron flux. (author)Fren. [French] L'objet de cette etude est la determination de plusieurs proprietes physiques de l'oxyde de beryllium fritte sous charge dans differentes conditions et l'evolution de ces proprietes apres irradiation. Une attention particuliere a ete portee sur la mesure de la conductibilite et de la diffusivite thermiques. Differents montages ont ete realises pour mesurer la conductibilite thermique. Ils permettent la determination entre 50 et 300 deg. C, entre 400 et 800 deg. C; quelques mesures ont ete faites au-dessus de 1000 deg. C. Pour la mesure du coefficient de diffusivite thermique, on realise une attaque thermique, de frequence et d'amplitude reglables d'une face parfaitement plane d'un echantillon d'oxyde de beryllium. Les variations de temperature sont

  1. Measuring elderly dysphagic patients' performance in eating--a review

    DEFF Research Database (Denmark)

    Hansen, Tina; Kjaersgaard, Annette; Faber, Jens

    2011-01-01

    Purpose. This review aims to identify psychometrically robust assessment tools suitable for measuring elderly dysphagic patients' performance in eating for use in clinical practice and research. Method. Electronic databases, related citations and references were searched to identify assessment...

  2. Beryllium toxicity testing in the suspension culture of mouse fibroblasts.

    Science.gov (United States)

    Rössner, P; Bencko, V

    1980-01-01

    Suspension culture of mouse fibroblast cell line L-A 115 was used to test beryllium toxicity in the presence of magnesium ions. Beryllium added to the MEM cultivation medium was bound in a complex with sulphosalicylic acid BeSSA complex, because the use of beryllium chloride turned out to yield ineffective beryllium phosphate that formed macroscopically detectable insoluble opacities. The BeSSA complex was used in the concentration range: 10(-3)--10(-9)M, magnesium was used in 3 concentrations: 10(-1)M, 5 x 10(-2)M and 10(-2)M. Growth curve analysis revealed pronounced beryllium toxicity at the concentration of 10(-3)M, magnesium-produced toxic changes were observed only at the concentration of 10(-1)M. No competition between the beryllium and magnesium ions was recorded. It is assumed that the possible beryllium-magnesium competition was significantly modified by the use of BeSSA complex-bound beryllium.

  3. Ionization energies of beryllium in strong magnetic fields

    Institute of Scientific and Technical Information of China (English)

    GUANXiao-xu; ZHANGYue-xia

    2004-01-01

    We have develop an effective frozen core approximation to calculate energy levels and ionization enegies of the beryllium atom in magnetic field strengths up to 2.35 × 105T. Systematic improvement over the Hartree-Fock results for the beryllium low-lying states has been accomplished.

  4. Joining of beryllium by braze welding technique: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Banaim, P.; Abramov, E. [Ben-Gurion Univ. of the Negev, Beersheba (Israel); Zalkind, S.; Eden, S.

    1998-01-01

    Within the framework of some applications, there is a need to join beryllium parts to each other. Gas Tungsten Arc Braze Welds were made in beryllium using 0.3 mm commercially Aluminum (1100) shim preplaced at the joint. The welds exhibited a tendency to form microcracks in the Fusion Zone and Heat Affected Zone. All the microcracks were backfilled with Aluminum. (author)

  5. Beryllium-10 in continental sediments

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L.; Sacks, I.S.; Tera, F. (Carnegie Institution of Washington, DC (USA). Dept. of Terrestrial Magnetism); Klein, J.; Middleton, R. (Pennsylvania Univ., Philadelphia (USA). Dept. of Physics)

    1981-11-01

    The concentration of /sup 10/Be has been measured in 10 samples taken from a transect of surface sediments beginning in the Atchafalaya River and extending across the Bay 136 km into the Gulf of Mexico. If corrected for a lower retentivity of sand for Be, they have a concentration that is constant within 13%. This concentration is about an order of magnitude smaller than that of deep ocean sediments. For comparison, measurements of /sup 10/Be in rainwater, in a sample of soil and in a deep ocean core were made.

  6. Specification for nuclear-grade beryllium oxide powder

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This specification defines the physical and chemical requirements of nuclear-grade beryllium oxide (BeO) powder to be used in fabricating nuclear components. 1.2 This specification does not include requirements for health and safety. , , It recognizes the material as a Class B poison and suggests that producers and users become thoroughly familiar with and comply to applicable federal, state, and local regulations and handling guidelines. 1.3 Special tests and procedures are given in Annex A1 and Annex A2. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  7. Stress distribution and fracture behavior of beryllium compact tension specimens

    International Nuclear Information System (INIS)

    Compact tension specimens of beryllium (Be) were designed to study fracture behavior and mechanical properties. The local stress distribution near a notch in a compact tension specimen was measured in situ by the combination of an X-ray stress analysis and a custom-designed load device. The fracture morphology was observed by scanning electron microscopy. The result showed that the local stresses near the notch tip are much higher than in other areas, and cracking occurs first in that area. The load-crack opening displacement curve of the Be compact tension specimen was obtained, and used to calculate the fracture toughness as 15.7 MPa√m. The compact tension specimen fracture surfaces were mainly characterized by cleavage fracture over three different areas. Cleavage micro-cracks along the basal slip plane were formed at the crack tip, and their growth was controlled by the primary stress after reaching a critical length

  8. Electromagnetic properties of the Beryllium-11 nucleus in Halo EFT

    Directory of Open Access Journals (Sweden)

    Hammer H.-W.

    2010-04-01

    Full Text Available We compute electromagnetic properties of the Beryllium-11 nucleus using an effective field theory that exploits the separation of scales in this halo system. We fix the parameters of the EFT from measured data on levels and scattering lengths in the 10Be plus neutron system. We then obtain predictions for the B(E1 strength of the 1/2+ to 1/2− transition in the 11Be nucleus. We also compute the charge radius of the ground state of 11Be. Agreement with experiment within the expected accuracy of a leading-order computation in this EFT is obtained. We also indicate how higher-order corrections that affect both s-wave and p-wave 10 Be-neutron interactions will affect our results.

  9. Ultra-trace determination of beryllium in occupational hygiene samples by ammonium bifluoride extraction and fluorescence detection using hydroxybenzoquinoline sulfonate.

    Science.gov (United States)

    Ashley, Kevin; Agrawal, Anoop; Cronin, John; Tonazzi, Juan; McCleskey, T Mark; Burrell, Anthony K; Ehler, Deborah S

    2007-02-19

    A highly sensitive molecular fluorescence method for measuring ultra-trace levels of beryllium has been previously described. The method entails extraction of beryllium workplace samples by 1% ammonium bifluoride (NH(4)HF(2), aqueous), followed by fluorescence detection using hydroxybenzoquinoline sulfonate (HBQS). In this work, modification of the existing procedure resulted in a significant improvement in detection power, thereby enabling ultra-trace determination of beryllium in air filter and surface wipe samples. Such low detection limits may be necessary in view of expected decreases in applicable occupational exposure limits (OELs) for beryllium. Attributes of the modified NH(4)HF(2) extraction/HBQS fluorescence method include method detection limits (MDLs) of <0.8 ng to approximately 2 ng Be per sample (depending on the fluorometer used), quantitative recoveries from beryllium oxide, a dynamic range of several orders of magnitude, and freedom from interferences. Other key advantages of the technique are field portability, relatively low cost, and high sample throughput. The method performance compares favorably with that of inductively coupled plasma-mass spectrometry (ICP-MS).

  10. Ultra-trace determination of beryllium in occupational hygiene samples by ammonium bifluoride extraction and fluorescence detection using hydroxybenzoquinoline sulfonate

    Energy Technology Data Exchange (ETDEWEB)

    Ashley, Kevin [U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 4676 Columbia Parkway, M.S. R-7, Cincinnati, OH 45226-1998 (United States)]. E-mail: kashley@cdc.gov; Agrawal, Anoop [Berylliant, Inc., 4541 E. Fort Lowell Road, Tucson, AZ 85712 (United States); Cronin, John [Berylliant, Inc., 4541 E. Fort Lowell Road, Tucson, AZ 85712 (United States); Tonazzi, Juan [Berylliant, Inc., 4541 E. Fort Lowell Road, Tucson, AZ 85712 (United States); McCleskey, T. Mark [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Burrell, Anthony K. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Ehler, Deborah S. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States)

    2007-02-19

    A highly sensitive molecular fluorescence method for measuring ultra-trace levels of beryllium has been previously described. The method entails extraction of beryllium workplace samples by 1% ammonium bifluoride (NH{sub 4}HF{sub 2}, aqueous), followed by fluorescence detection using hydroxybenzoquinoline sulfonate (HBQS). In this work, modification of the existing procedure resulted in a significant improvement in detection power, thereby enabling ultra-trace determination of beryllium in air filter and surface wipe samples. Such low detection limits may be necessary in view of expected decreases in applicable occupational exposure limits (OELs) for beryllium. Attributes of the modified NH{sub 4}HF{sub 2} extraction/HBQS fluorescence method include method detection limits (MDLs) of <0.8 ng to {approx}2 ng Be per sample (depending on the fluorometer used), quantitative recoveries from beryllium oxide, a dynamic range of several orders of magnitude, and freedom from interferences. Other key advantages of the technique are field portability, relatively low cost, and high sample throughput. The method performance compares favorably with that of inductively coupled plasma-mass spectrometry (ICP-MS)

  11. Preparation and characterization of beryllium doped organic plasma polymer coatings

    International Nuclear Information System (INIS)

    We report the formation of beryllium doped plasma polymerized coatings derived from a helical resonator deposition apparatus, using diethylberyllium as the organometaric source. These coatings had an appearance not unlike plain plasma polymer and were relatively stable to ambient exposure. The coatings were characterized by Inductively Coupled Plasma Mass Spectrometry and X-Ray Photoelectron Spectroscopy. Coating rates approaching 0.7 μm hr-1 were obtained with a beryllium-to-carbon ratio of 1:1.3. There is also a significant oxygen presence in the coating as well which is attributed to oxidation upon exposure of the coating to air. The XPS data show only one peak for beryllium with the preponderance of the XPS data suggesting that the beryllium exists as BeO. Diethylberyllium was found to be inadequate as a source for beryllium doped plasma polymer, due to thermal decomposition and low vapor recovery rates

  12. Spectrofluorimetric Determination of Beryllium by Mean Centering of Ratio Spectra.

    Science.gov (United States)

    Chamsaz, Mahmoud; Samghani, Kobra; Arbab-Zavar, Mohammad Hossein; Heidari, Tahereh

    2016-07-01

    Trace amounts of beryllium has been determined by spectrofluorimetric method that used morin as fluorimetric reagent. Beryllium gives a highly fluorescent complex with morin. The excitation wavelength of morin and Be-morin complex were 410 and 430. The fluorescence spectra of morin and Be-morin complex were overlaped in excitation wavelength of 430 nm. A method based on mean centering of ratio spectra has been performed to remove the interference caused by morin as it overlaps with the Be-morin spectra. The linear range of beryllium concentration is in 0.2-200 ppb range. The parameters of detection limit and RSD were 0.18 ppb and 4.6 % respectively. This method was used for determination of beryllium in copper-beryllium alloy as a real sample. In determination of Be(II), the interference by Cu(II) was very serious, which was eliminated by adding triethanolamine. PMID:27265354

  13. Stepped-anneal helium release in 1-mm beryllium pebbles from COBRA-1A2

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, B.M. [Pacific Northwest National Lab., Richland, WA (United States)

    1998-03-01

    Stepped-anneal helium release measurements on two sets of fifteen beryllium pebbles irradiated in the Experimental Breeder Reactor-II (EBR-II) at Argonne National Laboratory-West (ANL-w), are reported. The purpose of the measurements was to determine the helium release characteristics of the beryllium using larger sample sizes and longer anneal times relative to earlier measurements. Sequential helium analyses were conducted over a narrower temperature range from approximately 800 C to 1100 C in 100 C increments, but with longer anneal time periods. To allow for overnight and unattended operation, a temperature controller and associated circuitry were added to the experimental setup. Observed helium release was nonlinear with time at each temperature interval, with each step being generally characterized by an initial release rate followed by a slowing of the rate over time. Sample Be-C03 showed a leveling off in the helium release after approximately 3 hours at a temperature of 890 C. Sample Be-D03, on the other hand, showed a leveling off only after {approximately}12 to 24 hours at a temperature of 1100 C. This trend is consistent with that observed in earlier measurements on single microspheres from the same two beryllium lots. None of the lower temperature steps showed any leveling off of the helium release. Relative to the total helium concentrations measured earlier, the total helium releases observed here represent approximately 80% and 92% of the estimated total helium in the C03 and D03 samples, respectively.

  14. A review of worldwide atmospheric mercury measurements

    Directory of Open Access Journals (Sweden)

    F. Sprovieri

    2010-09-01

    Full Text Available A large number of activities have been carried out to characterise the levels of mercury (Hg species in ambient air and precipitation, in order to understand how they vary over time and how they depend on meteorological conditions. Following the discovery of atmospheric Hg depletion events (AMDEs in Polar Regions, a significant research effort was made to assess the chemical-physical mechanisms behind the rapid conversion of atmospheric gaseous Hg (Hg0 into reactive and water-soluble forms which are potentially bioavailable. The understanding of the way in which Hg is released into the atmosphere, transformed, deposited and eventually incorporated into biota is of crucial importance not only for the polar regions but also for the marine environment in general. The oceans and seas are both sources and sinks of Hg and play a major role in the Hg cycle. In this work, the available Hg concentration datasets from a number of terrestrial sites (industrial, rural and remote in both the Northern and Southern Hemispheres as well as over oceans and seas have been investigated. The higher Hg species concentration and variability observed in the Northern Hemisphere suggest that the majority of emissions and re-emissions occur there. The inter-hemispherical gradient with higher total gaseous mercury (TGM concentrations in the Northern Hemisphere has remained nearly constant over the years for which data are available. The analysis of Hg concentration patterns indicates the differences in regional source/sink characteristics, with increasing variability toward areas strongly influenced by anthropogenic sources. The large increase in Hg emissions in rapidly developing countries (i.e., China, India over the last decade, due primarily to a sharp increase in energy production from coal combustion, are not currently reflected in the long-term measurements of TGM in ambient air and precipitation at continuous monitoring sites in either Northern Europe or

  15. Trace-level beryllium analysis in the laboratory and in the field: State of the art, challenges, and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    BRISSON, MICHAEL

    2006-03-30

    Control of workplace exposure to beryllium is a growing issue in the United States and other nations. As the health risks associated with low-level exposure to beryllium are better understood, the need increases for improved analytical techniques both in the laboratory and in the field. These techniques also require a greater degree of standardization to permit reliable comparison of data obtained from different locations and at different times. Analysis of low-level beryllium samples, in the form of air filters or surface wipes, is frequently required for workplace monitoring or to provide data to support decision-making on implementation of exposure controls. In the United States and the United Kingdom, the current permissible exposure level is 2 {micro}g/m{sup 3} (air), and the United States Department of Energy has implemented an action level of 0.2 {micro}g/m{sup 3} (air) and 0.2 {micro}g/100 cm{sup 2} (surface). These low-level samples present a number of analytical challenges, including (1) a lack of suitable standard reference materials, (2) unknown robustness of sample preparation techniques, (3) interferences during analysis, (4) sensitivity (sufficiently low detection limits), (5) specificity (beryllium speciation), and (6) data comparability among laboratories. Additionally, there is a need for portable, real-time (or near real-time) equipment for beryllium air monitoring and surface wipe analysis that is both laboratory-validated and field-validated in a manner that would be accepted by national and/or international standards organizations. This paper provides a review of the current analytical requirements for trace-level beryllium analysis for worker protection, and also addresses issues that may change those requirements. The current analytical state of the art and relevant challenges facing the analytical community will be presented, followed by suggested criteria for real-time monitoring equipment. Recognizing and addressing these challenges will

  16. Sedimentation in mountain streams: A review of methods of measurement

    Science.gov (United States)

    Hedrick, Lara B.; Anderson, James T.; Welsh, Stuart; Lin, Lian-Shin

    2013-01-01

    The goal of this review paper is to provide a list of methods and devices used to measure sediment accumulation in wadeable streams dominated by cobble and gravel substrate. Quantitative measures of stream sedimentation are useful to monitor and study anthropogenic impacts on stream biota, and stream sedimentation is measurable with multiple sampling methods. Evaluation of sedimentation can be made by measuring the concentration of suspended sediment, or turbidity, and by determining the amount of deposited sediment, or sedimentation on the streambed. Measurements of deposited sediments are more time consuming and labor intensive than measurements of suspended sediments. Traditional techniques for characterizing sediment composition in streams include core sampling, the shovel method, visual estimation along transects, and sediment traps. This paper provides a comprehensive review of methodology, devices that can be used, and techniques for processing and analyzing samples collected to aid researchers in choosing study design and equipment.

  17. Glass-Coated Beryllium Mirrors for the LHCb RICH1 Detector

    CERN Document Server

    Barber, G J; Cameron, W; D'Ambrosio, C; Frei, C; Harnew, N; Head, R; Khimitch, Y P; Khmelnikov, V A; Loveridge, P W; Metlica, F; Obraztsov, V F; Piedigrossi, D; Sizenev, V; Kompozit Joint Stock Company, Moscow, Russia; Szczypka, P M; Ullaland, O; Vygosky, E; Websdale, D M

    2007-01-01

    The design, manufacture and testing of lightweight glass-coated beryllium spherical converging mirrors for the RICH1 detector of LHCb are described. The mirrors need to be lightweight to minimize the material budget and fluorocarbon-compatible to avoid degradation in the RICH1 C4F10 gas radiator. Results of the optical measurements for the small-sized prototypes and for the first full-sized prototype mirror are reported.

  18. Use of a Paraffin Based Grout to Stabilize Buried Beryllium and Other Wastes

    Energy Technology Data Exchange (ETDEWEB)

    Gretchen Matthern; Duane Hanson; Neal Yancey; Darrell Knudson

    2005-12-01

    The long term durability of WAXFIXi, a paraffin based grout, was evaluated for in situ grouting of activated beryllium wastes in the Subsurface Disposal Area (SDA), a radioactive landfill at the Radioactive Waste Management Complex, part of the Idaho National Laboratory (INL). The evaluation considered radiological and biological mechanisms that could degrade the grout using data from an extensive literature search and previous tests of in situ grouting at the INL. Conservative radioactive doses for WAXFIX were calculated from the "hottest" (i.e., highest-activity) Advanced Test Reactor beryllium block in the SDA.. These results indicate that WAXFIX would not experience extensive radiation damage for many hundreds of years. Calculation of radiation induced hydrogen generation in WAXFIX indicated that grout physical performance should not be reduced beyond the effects of radiation dose on the molecular structure. Degradation of a paraffin-based grout by microorganisms in the SDA is possible and perhaps likely, but the rate of degradation will be at a slower rate than found in the literature reviewed. The calculations showed the outer 0.46 m (18 in.) layer of each monolith, which represents the minimum expected distance to the beryllium block, was calculated to require 1,000 to 3,600 years to be consumed. The existing data and estimations of biodegradation and radiolysis rates

  19. Inhibitory effects of beryllium chloride on rat liver microsomal enzymes.

    Science.gov (United States)

    Teixeira, C F; Yasaka, W J; Silva, L F; Oshiro, T T; Oga, S

    1990-04-30

    A single i.v. dose (0.1 mmol Be2+/kg) of beryllium chloride prolonged the duration of pentobarbital-induced sleep and zoxazolamine-induced paralysis, in rats. The effects are correlated with changes of the pharmacokinetic parameters and with the in vitro inhibition of both aliphatic and aromatic hydroxylation of pentobarbital and zoxazolamine. In vitro N-demethylation of meperidine and aminopyrine was partially inhibited while O-demethylation of quinidine was unaffected by liver microsomes of rats pretreated with beryllium salt. The findings give clues that beryllium chloride inhibits some forms of cytochrome P-450, especially those responsible for hydroxylation of substrates, like pentobarbital and zoxazolamine.

  20. Analysis of surface contaminants on beryllium and aluminum windows

    International Nuclear Information System (INIS)

    An effort has been made to document the types of contamination which form on beryllium windows surfaces due to interaction with a synchrotron radiation beam. Beryllium windows contaminated in a variety of ways (exposure to water and air) exhibited surface powders, gels, crystals and liquid droplets. These contaminants were analyzed by electron diffraction, electron energy loss spectroscopy, energy dispersive X-ray spectroscopy and wet chemical methods. Materials found on window surfaces include beryllium oxide, amorphous carbon, cuprous oxide, metallic copper and nitric acid. Aluminum window surface contaminants were also examined. (orig.)

  1. Beryllium Health and Safety Committee Data Reporting Task Force

    Energy Technology Data Exchange (ETDEWEB)

    MacQueen, D H

    2007-02-21

    On December 8, 1999, the Department of Energy (DOE) published Title 10 CFR 850 (hereafter referred to as the Rule) to establish a chronic beryllium disease prevention program (CBDPP) to: {sm_bullet} reduce the number of workers currently exposed to beryllium in the course of their work at DOE facilities managed by DOE or its contractors, {sm_bullet} minimize the levels of, and potential for, expos exposure to beryllium, and {sm_bullet} establish medical surveillance requirements to ensure early detection of the disease.

  2. Measuring Health Literacy in Individuals with Diabetes: A Systematic Review and Evaluation of Available Measures

    Science.gov (United States)

    Al Sayah, Fatima; Williams, Beverly; Johnson, Jeffrey A.

    2013-01-01

    Objective: To identify instruments used to measure health literacy and numeracy in people with diabetes; evaluate their use, measurement scope, and properties; discuss their strengths and weaknesses; and propose the most useful, reliable, and applicable measure for use in research and practice settings. Methods" A systematic literature review was…

  3. Extraction of beryllium from refractory beryllium oxide with dilute ammonium bifluoride and determination by fluorescence: a multiparameter performance evaluation.

    Science.gov (United States)

    Goldcamp, Michael J; Goldcamp, Diane M; Ashley, Kevin; Fernback, Joseph E; Agrawal, Anoop; Millson, Mark; Marlow, David; Harrison, Kenneth

    2009-12-01

    Beryllium exposure can cause a number of deleterious health effects, including beryllium sensitization and the potentially fatal chronic beryllium disease. Efficient methods for monitoring beryllium contamination in workplaces are valuable to help prevent dangerous exposures to this element. In this work, performance data on the extraction of beryllium from various size fractions of high-fired beryllium oxide (BeO) particles (from bifluoride (ABF) solution were obtained under various conditions. Beryllium concentrations were determined by fluorescence using a hydroxybenzoquinoline fluorophore. The effects of ABF concentration and volume, extraction temperature, sample tube types, and presence of filter or wipe media were examined. Three percent ABF extracts beryllium nearly twice as quickly as 1% ABF; extraction solution volume has minimal influence. Elevated temperatures increase the rate of extraction dramatically compared with room temperature extraction. Sample tubes with constricted tips yield poor extraction rates owing to the inability of the extraction medium to access the undissolved particles. The relative rates of extraction of Be from BeO of varying particle sizes were examined. Beryllium from BeO particles in fractions ranging from less than 32 microm up to 212 microm were subjected to various extraction schemes. The smallest BeO particles are extracted more quickly than the largest particles, although at 90 degrees C even the largest BeO particles reach nearly quantitative extraction within 4 hr in 3% ABF. Extraction from mixed cellulosic-ester filters, cellulosic surface-sampling filters, wetted cellulosic dust wipes, and cotton gloves yielded 90% or greater recoveries. Scanning electron microscopy of BeO particles, including partially dissolved particles, shows that dissolution in dilute ABF occurs not just on the exterior surface but also via accessing particles' interiors due to porosity of the BeO material. Comparison of dissolution kinetics data

  4. Low cycle thermal fatigue testing of beryllium grades for ITER plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Watson, R.D.; Youchison, D.L. [Sandia National Labs., Livermore, CA (United States); Dombrowski, D.E. [Brush Wellman, Inc., Cleveland, OH (United States); Guiniatouline, R.N. [Efremov Institute, (Russia); Kupriynov, I.B. [Russian Institute of Inorganic Materials (Russia)

    1996-02-01

    A novel technique has been used to test the relative low cycle thermal fatigue resistance of different grades of US and Russian beryllium, which is proposed as plasma facing armor for fusion reactor first wall, limiter, and divertor components. The 30 kW electron beam test system at Sandia National Laboratories was used to sweep the beam spot along one direction at 1 Hz. This produces a localized temperature ``spike`` of 750{degree}C for each pass of the beam. Large thermal stresses in excess of the yield strength are generated due to very high spot heat flux, 250 MW/m{sup 2}. Cyclic plastic strains on the order of 0.6% produced visible cracking on the heated surface in less than 3000 cycles. An in-vacuo fiber optic borescope was used to visually inspect the beryllium surfaces for crack initiation. Grades of US beryllium tested included: S-65C, S- 65H, S-200F, S-200F-H, SR-200, I-400, extruded high purity, HIP`d spherical powder, porous beryllium (94% and 98% dense), Be/30% BeO, Be/60% BeO, and TiBe{sub 12}. Russian grades included: TGP-56, TShGT, DShG-200, and TShG-56. Both the number of cycles to crack initiation, and the depth of crack propagation, were measured. The most fatigue resistant grades were S-65C, DShG-200, TShGT, and TShG-56. Rolled sheet Be (SR-200) showed excellent crack propagation resistance in the plane of rolling, despite early formation of delamination cracks. Only one sample showed no evidence of surface melting, Extruded (T). Metallographic and chemical analyses are provided. Good agreement was found between the measured depth of cracks and a 2-D elastic-plastic finite element stress analysis.

  5. Resting Doppler ankle brachial pressure index measurement: a literature review.

    Science.gov (United States)

    Sihlangu, Dorcus; Bliss, Julie

    2012-07-01

    Peripheral vascular disease (PVD) is under-diagnosed in primary and acute settings. The use of Doppler ankle brachial pressure index (ABPI) is effective in diagnosing PVD , aid in determining aetiology of leg ulcers and is cost efficient in reducing the effects of atherosclerosis and cardiovascular events. The aim of this literature review was to review practitioners' experience in using Doppler ABPI, different skills used to measure ABPI and to examine practitioners' confidence in ABPI. The findings identified variation in method for Doppler measurement: including position of the artery, arm measurement, resting period and type of equipment for measuring blood pressure, variations in practitioners' training and experience have demonstrated variability in ABPI results. Although limited in number, the studies have demonstrated knowledge gap, and the need for training among health professionals. PMID:22875182

  6. Measuring religiousness in health research: review and critique.

    Science.gov (United States)

    Hall, Daniel E; Meador, Keith G; Koenig, Harold G

    2008-06-01

    Although existing measures of religiousness are sophisticated, no single approach has yet emerged as a standard. We review the measures of religiousness most commonly used in the religion and health literature with particular attention to their limitations, suggesting that vigilance is required to avoid over-generalization. After placing the development of these scales in historical context, we discuss measures of religious attendance, private religious practice, and intrinsic/extrinsic religious motivation. We also discuss measures of religious coping, wellbeing, belief, affiliation, maturity, history, and experience. We also address the current trend in favor of multi-dimensional and functional measures of religiousness. We conclude with a critique of the standard, "context-free" approach aimed at measuring "religiousness-in-general", suggesting that future work might more fruitfully focus on developing ways to measure religiousness in specific, theologically relevant contexts. PMID:19105008

  7. An analytical review of hospital financial performance measures.

    Science.gov (United States)

    Glandon, G L; Counte, M; Holloman, K; Kowalczyk, J

    1987-11-01

    Hospital administrators must have timely, valid, and interpretable financial information that allows them to make operational decisions in response to the threats of the changing health care environment. Aggregate indexes that reflect dimensions of hospital financial performance and simplify the information in financial ratios are needed to aid in decision making. This article reviews the development and use of hospital financial performance measures and lays the groundwork for research into deriving a multidimensional measure.

  8. Measuring High School Graduation Rates: A Review of the Literature

    Science.gov (United States)

    Savich, Carl

    2007-01-01

    This paper reviewed the research literature on graduation rates in U.S. high schools to evaluate and assess the findings. The methodology employed was to determine the measuring method that researchers used in reaching their findings. The strengths and weaknesses of the method employed were then analyzed. Flaws and inaccuracies were examined and…

  9. Performance measurement for product lifecycle management: a systemact literature review

    Directory of Open Access Journals (Sweden)

    Fernando Fonseca

    2012-01-01

    Full Text Available The aim of this study is to identify recommendations as well as the main performance indicator for developing a performance measurement system (PMS for product lifecycle management (PLM approach. Thus it was performed a systematic literature review that identified 22 recommendations and 296 performance indicators.

  10. Workplace Discrimination, Prejudice, and Diversity Measurement: A Review of Instrumentation.

    Science.gov (United States)

    Burkard, Alan W.; Boticki, Michael A.; Madson, Michael B.

    2002-01-01

    Critically reviews diversity measures in terms of item development, psychometric evidence, and utility for counseling and development: Workplace Prejudice/Discrimination Inventory, Attitudes toward Diversity Scale; Organizational Diversity Inventory, Workforce Diversity Questionnaire, Perceived Occupational Opportunity Scale-Form B, and Perceived…

  11. The Validity of Attribute-Importance Measurement: A Review

    NARCIS (Netherlands)

    Ittersum, van K.; Pennings, J.M.E.; Wansink, B.; Trijp, van J.C.M.

    2007-01-01

    A critical review of the literature demonstrates a lack of validity among the ten most common methods for measuring the importance of attributes in behavioral sciences. The authors argue that one of the key determinants of this lack of validity is the multi-dimensionality of attribute importance. Bu

  12. Wind measurements for wind energy applications. A review

    DEFF Research Database (Denmark)

    Mortensen, N.G.

    1994-01-01

    A review is given of the error sources and uncertainties in cup and sonic anemometry. In both cases the effects of the tower, boom and other mounting arrangements, as well as the siting of the anemometer, should be considered carefully. Cup anemometer measurements are inherently biased due to the...

  13. New facility for post irradiation examination of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Ishitsuka, Etsuo; Kawamura, Hiroshi [Oarai Research Establishment, Ibaraki-Ken (Japan)

    1995-09-01

    Beryllium is expected as a neutron multiplier and plasma facing materials in the fusion reactor, and the neutron irradiation data on properties of beryllium up to 800{degrees}C need for the engineering design. The acquisition of data on the tritium behavior, swelling, thermal and mechanical properties are first priority in ITER design. Facility for the post irradiation examination of neutron irradiated beryllium was constructed in the hot laboratory of Japan Materials Testing Reactor to get the engineering design data mentioned above. This facility consist of the four glove boxes, dry air supplier, tritium monitoring and removal system, storage box of neutron irradiated samples. Beryllium handling are restricted by the amount of tritium;7.4 GBq/day and {sup 60}Co;7.4 MBq/day.

  14. Development of Biomarkers for Chronic Beryllium Disease in Mice

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, Terry

    2013-01-25

    Beryllium is a strategic metal, indispensable for national defense programs in aerospace, telecommunications, electronics, and weaponry. Exposure to beryllium is an extensively documented occupational hazard that causes irreversible, debilitating granulomatous lung disease in as much as 3 - 5% of exposed workers. Mechanistic research on beryllium exposure-disease relationships has been severely limited by a general lack of a sufficient CBD animal model. We have now developed and tested an animal model which can be used for dissecting dose-response relationships and pathogenic mechanisms and for testing new diagnostic and treatment paradigms. We have created 3 strains of transgenic mice in which the human antigen-presenting moiety, HLA-DP, was inserted into the mouse genome. Each mouse strain contains HLA-DPB1 alleles that confer different magnitude of risk for chronic beryllium disease (CBD): HLA-DPB1*0401 (odds ratio = 0.2), HLA-DPB1*0201 (odds ratio = 15), HLA-DPB1*1701 (odds ratio = 240). Our preliminary work has demonstrated that the *1701 allele, as predicted by human studies, results in the greatest degree of sensitization in a mouse ear swelling test. We have also completed dose-response experiments examining beryllium-induced lung granulomas and identified susceptible and resistant inbred strains of mice (without the human transgenes) as well as quantitative trait loci that may contain gene(s) that modify the immune response to beryllium. In this grant application, we propose to use the transgenic and normal inbred strains of mice to identify biomarkers for the progression of beryllium sensitization and CBD. To achieve this goal, we propose to compare the sensitivity and accuracy of the lymphocyte proliferation test (blood and bronchoalveolar lavage fluid) with the ELISPOT test in the three HLA-DP transgenic mice strains throughout a 6 month treatment with beryllium particles. Because of the availability of high-throughput proteomics, we will also identify

  15. The beryllium production at Ulba metallurgical plant (Ust-Kamenogrsk, Kazakhstan)

    Energy Technology Data Exchange (ETDEWEB)

    Dvinskykh, E.M.; Savchuk, V.V.; Tuzov, Y.V. [Ulba Metallurgical Plant (Zavod), Ust-Kamenogorsk, Abay prospect 102 (Kazakhstan)

    1998-01-01

    The Report includes data on beryllium production of Ulba metallurgical plant, located in Ust-Kamenogorsk (Kazakhstan). Beryllium production is showed to have extended technological opportunities in manufacturing semi-products (beryllium ingots, master alloys, metallic beryllium powders, beryllium oxide) and in production of structural beryllium and its parts. Ulba metallurgical plant owns a unique technology of beryllium vacuum distillation, which allows to produce reactor grades of beryllium with a low content of metallic impurities. At present Ulba plant does not depend on raw materials suppliers. The quantity of stored raw materials and semi-products will allow to provide a 25-years work of beryllium production at a full capacity. The plant has a satisfactory experience in solving ecological problems, which could be useful in ITER program. (author)

  16. Beryllium nitride thin film grown by reactive laser ablation

    OpenAIRE

    G. Soto; Diaz, J.A.; Machorro, R.; Reyes-Serrato, A.; de la Cruz, W.

    2001-01-01

    Beryllium nitride thin films were grown on silicon substrates by laser ablating a beryllium foil in molecular nitrogen ambient. The composition and chemical state were determined with Auger (AES), X-Ray photoelectron (XPS) and energy loss (EELS) spectroscopies. A low absorption coefficient in the visible region, and an optical bandgap of 3.8 eV, determined by reflectance ellipsometry, were obtained for films grown at nitrogen pressures higher than 25 mTorr. The results show that the reaction ...

  17. Hydration of beryllium(II) in aqueous solutions of common inorganic salts. A combined vibrational spectroscopic and ab initio molecular orbital study.

    Science.gov (United States)

    Rudolph, Wolfram W; Fischer, Dieter; Irmer, Gert; Pye, Cory C

    2009-09-01

    Raman spectra of aqueous beryllium perchlorate, chloride, nitrate, and sulfate solutions have been measured over a broad concentration (0.098-4.950 mol L(-1)) range. The Raman spectroscopic data suggest that the tetra-aqua beryllium(II) ion is thermodynamically stable in perchlorate, chloride, and nitrate solutions over the concentration range measured. No inner-sphere complexes in these solutions could be detected spectroscopically except in very concentrated beryllium nitrate solutions. Beryllium sulfate solutions however, show a different picture, namely the existence of a thermodynamically stable beryllium sulfato complex most likely monodentate even at very low concentrations. At very high beryllium sulfate concentrations, a small quantity of a bidentate sulfato complex was found. With a temperature increase, the sulfato complex formation increases and this demonstrates the entropically driven sulfato complex formation. Furthermore, with increased temperature the hydrolysis increases, measured by the formation of hydrogen sulfate. Ab initio geometry optimizations and frequency calculations are reported for beryllium-water clusters with only inner sphere waters, clusters with an inner sphere and an incomplete second hydration, and clusters with a higher number of waters in the second hydration sphere. The cluster, [Be(OH2)(12)(2+)] (Be[4 + 8]) with 4 water molecules in the first sphere and 8 water molecules in the second sphere gave sufficiently realistic frequencies for BeO4 skeleton in comparison to the experimental ones. However, the cluster, [Be(OH2)(18)(2+)] (Be[6 + 12]) with 6 water molecules in the inner sphere and 12 water molecules in the outer sphere on an energy minimum gave unrealistically low BeO4 frequencies. This fact demonstrates that a six-fold coordination of Be2+ can be ruled out.

  18. Systematic review of ground reaction force measurements in cats.

    Science.gov (United States)

    Schnabl, E; Bockstahler, B

    2015-10-01

    Although orthopaedic abnormalities in cats are frequently observed radiographically, they remain clinically underdiagnosed, and kinetic motion analysis, a fundamental aspect of orthopaedic research in dogs and horses, is not commonly performed. More information obtained with non-invasive measurement techniques to assess normal and abnormal gait in cats would provide a greater insight into their locomotion and biomechanics and improve the objective measurement of disease alterations and treatment modalities. In this systematic review, 12 previously performed studies that investigated ground reaction force measurements in cats during locomotion were evaluated. The aims of these studies, the measurement methods and equipment used, and the outcomes of parameters used to assess both sound and diseased cats are summarised and discussed. All reviewed studies used pressure sensitive walkways to gain data and all provided an acclimatisation period as a prerequisite for measurements. In sound cats during walking, the forelimb peak vertical force was greater than in the hindlimb and the peak vertical force in the hindlimb was greater in cats than in dogs. This review confirms that ground reaction forces can be used to evaluate lameness and treatment effects in the cat. PMID:26118478

  19. Beryllium pressure vessels for creep tests in magnetic fusion energy

    International Nuclear Information System (INIS)

    Beryllium has interesting applications in magnetic fusion experimental machines and future power-producing fusion reactors. Chief among the properties of beryllium that make these applications possible is its ability to act as a neutron multiplier, thereby increasing the tritium breeding ability of energy conversion blankets. Another property, the behavior of beryllium in a 14-MeV neutron environment, has not been fully investigated, nor has the creep behavior of beryllium been studied in an energetic neutron flux at thermodynamically interesting temperatures. This small beryllium pressure vessel could be charged with gas to test pressures around 3, 000 psi to produce stress in the metal of 15,000 to 20,000 psi. Such stress levels are typical of those that might be reached in fusion blanket applications of beryllium. After contacting R. Powell at HEDL about including some of the pressure vessels in future test programs, we sent one sample pressure vessel with a pressurizing tube attached (Fig. 1) for burst tests so the quality of the diffusion bond joints could be evaluated. The gas used was helium. Unfortunately, budget restrictions did not permit us to proceed in the creep test program. The purpose of this engineering note is to document the lessons learned to date, including photographs of the test pressure vessel that show the tooling necessary to satisfactorily produce the diffusion bonds. This document can serve as a starting point for those engineers who resume this task when funds become available

  20. Assessment of irradiation effects on beryllium reflector and heavy water tank of JRR-3M

    Energy Technology Data Exchange (ETDEWEB)

    Murayama, Yoji; Kakehuda, Kazuhiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-10-01

    The JRR-3M, a swimming pool type research reactor with beryllium and heavy water reflectors, has been operated since 1990. Since the beryllium reflectors are close to fuel and receive high fast neutron fluence in a relatively short time, they may be subject to change their dimensions by swelling due mostly to entrapped helium gaseous. This may bend the reflectors to the outside and narrow gaps between the reflectors and the fuel elements. The gaps have been measured with an ultrasonic thickness gage in an annual inspection. The results in 1996 show that the maximum of expansion in the diametral directions was 0.6 mm against 1.6 mm of a managed value for replacement of the reflector. A heavy water tank of the JRR-3M is made of aluminum alloy A5052. Surveillance tests of the alloy have been conducted to evaluate irradiation effects of the heavy water tank. Five sets of specimens of the alloy have been irradiated in the beryllium reflectors where fast neutron flux is higher than that in the heavy water tank. In 1994, one set of specimens had been unloaded and carried out the post-irradiation tests. The results show that the heavy water tank preserved satisfactory mechanical properties. (author)

  1. Experimental investigation of the energy and temperature dependence of beryllium self sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Korshunov, S.N.; Guseva, M.I.; Stolijarova, V.G. [RRC Kurchatov Institute, Moscow (Russian Federation)

    1995-09-01

    The low-Z metal beryllium is considered as plasma facing material (PFM) for the ITER. It is expected that operation temperature range of beryllium PFM will be (670 - 1070) K. While experimental Be-sputtering data bases exist for H{sup +}, D{sup +} and He{sup +}-ions, the self-sputtering yields of Be have only been estimated by computer simulation. In this paper we report the experimental results on the energy and temperature dependence of the beryllium self-sputtering yield (S). The energy dependence of S{sup s} in the energy range (0.5 - 10.0) keV was measured at 670 K. The self-sputtering yield of Be attains its maximal value at the ion energy of 1.5 keV, being equal to 0.32 {+-} at./ion. Comparison of the experimental results and theoretical prediction shows a good agreement for energy dependence of S{sup s}. The temperature dependence of S{sup s} in the temperature range (370-1070)K was obtained for 0.9keV Be{sup +}-ions. The value of S{sup s} is not changed up to 870 K. It sharply increases at the temperatures above 870 attaining the value of 0.75 at./ion at 1070 K.

  2. Erosion of beryllium under high-flux plasma impact

    Energy Technology Data Exchange (ETDEWEB)

    Doerner, R.P., E-mail: rdoerner@ucsd.edu [Center for Energy Research, UCSD, La Jolla, CA 92093-0417 (United States); Björkas, C. [EURATOM-Tekes, Department of Physics, University of Helsinki, P.O.B. 64, 00014 Helsinki (Finland); Institute for Energy Research-Plasma Physics, Forchungszentrun Jülich GmbH, 52425 Jülich (Germany); Nishijima, D. [Center for Energy Research, UCSD, La Jolla, CA 92093-0417 (United States); Schwarz-Selinger, T. [Max-Planck Institut für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany)

    2013-07-15

    Be sputtering yields, measured by weight loss, in PISCES-B are a factor of 5–10 less than that predicted by binary collision approximations. Measurements show the BeO surface is removed early in the plasma bombardment. Modeling of molecular ions (D{sub 2}{sup +} and D{sub 3}{sup +}) species and redeposition cannot explain the difference. Surface morphology that evolves during the exposure reduces the sputtering yield by a factor of 2–3. Plasma fuel atoms retained in the surface decrease the sputtering yield compared to calculations of a pure Be surface. These effects may explain the measured erosion rates in the absence of Be impurities within the plasma. By introducing Be impurity ions into the plasma, it is possible to simulate a controllable amount of redeposition. The weight loss from eroding Be targets, with Be seeding, is unchanged until the concentration of Be ions in the plasma greatly exceeds the sputtering yield in the non-beryllium seeded exposure.

  3. Beryllium data base for in-pile mockup test on blanket of fusion reactor, (1)

    International Nuclear Information System (INIS)

    Beryllium has been used in the fusion blanket designs with ceramic breeder as a neutron multiplier to increase the net tritium breeding ratio (TBR). The properties of beryllium, that is physical properties, chemical properties, thermal properties, mechanical properties, nuclear properties, radiation effects, etc. are necessary for the fusion blanket design. However, the properties of beryllium have not been arranged for the fusion blanket design. Therefore, it is indispensable to check and examine the material data of beryllium reported previously. This paper is the first one of the series of papers on beryllium data base, which summarizes the reported material data of beryllium. (author)

  4. Ação promotora do berílio em catalisadores da síntese do estireno Promotor action of beryllium in catalysts for styrene production

    Directory of Open Access Journals (Sweden)

    Mário Nilo Mendes Barbosa

    1997-10-01

    Full Text Available The catalytic dehydrogenation of ethylbenzene in presence of steam is the main commercial route to produce styrene. The industrial catalysts are potassium- and chromia-doped hematite which show low surface areas leading to bad performance and short life. In order to develop catalysts with high areas, the effect of beryllium on the textural properties and on the catalytic performance of this iron oxide was studied. The influence of the amount of the dopant, the starting material and the calcination temperature were also studied. In sample preparations, iron and beryllium salts (nitrate or sulfate were hydrolyzed with ammonia and then calcinated. The experiments followed a factorial design with two variables in two levels (Fe/Be= 3 and 7; calcination temperature= 500 and 700ºC. Solids without any dopant were also prepared. Samples were characterized by elemental analysis, infrared spectroscopy, surface area and porosity measurements, X-ray diffraction, DSC and TG. The catalysts were tested in a microreactor at 524ºC and 1 atm, by using a mole ratio of steam/ ethylbenzene=10. The selectivity was measured by monitoring styrene, benzene and toluene formation. It was found that the effect of beryllium on the characteristics of hematite and on its catalytic performance depends on the starting material and on the amount of dopant. Surface areas increased due to the dopant as well as the nature of the precursor; samples produced by beryllium sulfate showed higher areas. Beryllium-doped solids showed a higher catalytic activity when compared to pure hematite, but no significant influence of the anion of starting material was noted. It can be concluded that beryllium acts as both textural and structural promoter. Samples with Fe/Be= 3, heated at 500ºC, lead to the highest conversion and were the most selective. However, catalysts prepared from beryllium sulfate are the most promising to ethylbenzene dehydrogenation due to their high surface area which

  5. Discriminant analysis for repeated measures data: a review

    Directory of Open Access Journals (Sweden)

    Lisa Lix

    2010-09-01

    Full Text Available Discriminant analysis (DA encompasses procedures for classifying observations into groups (i.e., predictive discriminative analysis and describing the relative importance of variables for distinguishing amongst groups (i.e., descriptive discriminative analysis. In recent years, a number of developments have occurred in DA procedures for the analysis of data from repeated measures designs. Specifically, DA procedures have been developed for repeated measures data characterized by missing observations and/or unbalanced measurement occasions, as well as high-dimensional data in which measurements are collected repeatedly on two or more variables. This paper reviews the literature on DA procedures for univariate and multivariate repeated measures data, focusing on covariance pattern and linear mixed-effects models. A numeric example illustrates their implementation using SAS software.

  6. Measuring parent food practices: a systematic review of existing measures and examination of instruments

    OpenAIRE

    Vaughn, Amber E; Tabak, Rachel G.; Bryant, Maria J.; Ward, Dianne S

    2013-01-01

    During the last decade, there has been a rapid increase in development of instruments to measure parent food practices. Because these instruments often measure different constructs, or define common constructs differently, an evaluation of these instruments is needed. A systematic review of the literature was conducted to identify existing measures of parent food practices and to assess the quality of their development. The initial search used terms capturing home environment, parenting behav...

  7. What is compassion and how can we measure it? A review of definitions and measures

    OpenAIRE

    Strauss, C; Lever Taylor, B.; J. Gu; Kuyken, W; Baer, R; Jones, F.W.; K. Cavanagh

    2016-01-01

    The importance of compassion is widely recognized and it is receiving increasing research attention. Yet, there is lack of consensus on definition and a paucity of psychometrically robust measures of this construct. Without an agreed definition and adequate measures, we cannot study compassion, measure compassion or evaluate whether interventions designed to enhance compassion are effective. In response, this paper proposes a definition of compassion and offers a systematic review of self- an...

  8. Beryllium abundance in turn-off stars of NGC 6752

    CERN Document Server

    Pasquini, L; Randich, S; Galli, D; Gratton, R G; Wolff, B; Pasquini, Luca; Bonifacio, Piercarlo; Randich, Sofia; Galli, Daniele; Gratton, Raffaele G.

    2006-01-01

    Aims: To measure the beryllium abundance in two TO stars of the Globular Cluster NGC 6752, one oxygen rich and sodium poor, the other presumably oxygen poor and sodium rich. Be abundances in these stars are used to put on firmer grounds the hypothesis of Be as cosmochronometer and to investigate the formation of Globular Clusters. Method:We present near UV spectra with resolution R$\\sim 45000$ obtained with the UVES spectrograph on the 8.2m VLT Kueyen telescope, analysed with spectrum synthesis based on plane parallel LTE model atmospheres. Results:Be is detected in the O rich star with log(Be/H)=-12.04 $\\pm$0.15, while Be is not detected in the other star for which we obtain the upper limit log(Be/H)$<$-12.2. A large difference in nitrogen abundance (1.6 dex) is found between the two stars. Conclusions:The Be measurement is compatible with what found in field stars with the same [Fe/H] and [O/H]. The 'Be age' of the cluster is found to be 13.3 Gyrs, in excellent agreement with the results from main sequen...

  9. Instruments measuring blunted affect in schizophrenia: a systematic review.

    Directory of Open Access Journals (Sweden)

    Sanja Kilian

    Full Text Available Blunted affect, also referred to as emotional blunting, is a prominent symptom of schizophrenia. Patients with blunted affect have difficulty in expressing their emotions. The work of Abrams and Taylor and their development of the Rating Scale for Emotional Blunting in the late 1970's was an early indicator that blunted affect could indeed be assessed reliably. Since then, several new instruments assessing negative symptoms with subscales measuring blunted affect have been developed. In light of this, we aim to provide researchers and clinicians with a systematic review of the different instruments used to assess blunted affect by providing a comparison of the type, characteristics, administration and psychometric properties of these instruments. Studies reporting on the psychometric properties of instruments assessing blunted affect in patients with schizophrenia were included. Reviews and case studies were excluded. We reviewed 30 full-text articles and included 15 articles and 10 instruments in this systematic review. On average the instruments take 15-30 minutes to administer. We found that blunted affect items common across all instruments assess: gestures, facial expressions and vocal expressions. The CAINS Self-report Expression Subscale, had a low internal consistency score. This suggests that this sub-scale does not reliably assess patients' self-reported blunted affect symptoms and is likely due to the nature of blunted affect. Instruments correlated minimally with instruments measuring positive symptoms and more importantly with depression suggesting that the instruments distinguish between seemingly similar symptoms.

  10. A review of impedance measurements of whole cells.

    Science.gov (United States)

    Xu, Youchun; Xie, Xinwu; Duan, Yong; Wang, Lei; Cheng, Zhen; Cheng, Jing

    2016-03-15

    Impedance measurement of live biological cells is widely accepted as a label free, non-invasive and quantitative analytical method to assess cell status. This method is easy-to-use and flexible for device design and fabrication. In this review, three typical techniques for impedance measurement, i.e., electric cell-substrate impedance sensing, Impedance flow cytometry and electric impedance spectroscopy, are reviewed from the aspects of theory, to electrode design and fabrication, and applications. Benefiting from the integration of microelectronic and microfluidic techniques, impedance sensing methods have expanded their applications to nearly all aspects of biology, including living cell counting and analysis, cell biology research, cancer research, drug screening, and food and environmental safety monitoring. The integration with other techniques, the fabrication of devices for certain biological assays, and the development of point-of-need diagnosis devices is predicted to be future trend for impedance sensing techniques. PMID:26513290

  11. A Systematic Review of the Measurement of Sustainable Diets.

    Science.gov (United States)

    Jones, Andrew D; Hoey, Lesli; Blesh, Jennifer; Miller, Laura; Green, Ashley; Shapiro, Lilly Fink

    2016-07-01

    Sustainability has become an integral consideration of the dietary guidelines of many countries in recent decades. However, a lack of clear metrics and a shared approach to measuring the multiple components of sustainable diets has hindered progress toward generating the evidence needed to ensure the credibility of new guidelines. We performed a systematic literature review of empirical research studies on sustainable diets to identify the components of sustainability that were measured and the methods applied to do so. Two independent reviewers systematically searched 30 databases and other sources with the use of a uniform set of search terms and a priori exclusion criteria. In total, 113 empirical studies were included in the final review. Nearly all of the studies were focused on high-income countries. Although there was substantial heterogeneity in the components of sustainability measured, the estimated greenhouse gas emissions (GHGEs) of various dietary patterns were by far most commonly measured (n = 71 studies). Estimating the GHGEs of foods through various stages of production, use, and recycling with the use of the Life Cycle Assessment approach was the most common method applied to measure the environmental impacts of diets (n = 49 studies). Many components of sustainable diets identified in existing conceptual frameworks are disproportionately underrepresented in the empirical literature, as are studies that examine consumer demand for sustainable dietary alternatives. The emphasis in the literature on high-income countries also overlooks the production and dietary alternatives most relevant to low- and middle-income countries. We propose 3 methodological and measurement approaches that would both improve the global relevance of our understanding of sustainable diets and attend more completely to the existing multidimensional, multiscale conceptual framing of sustainable diets. PMID:27422501

  12. A Systematic Review of the Measurement of Sustainable Diets.

    Science.gov (United States)

    Jones, Andrew D; Hoey, Lesli; Blesh, Jennifer; Miller, Laura; Green, Ashley; Shapiro, Lilly Fink

    2016-07-01

    Sustainability has become an integral consideration of the dietary guidelines of many countries in recent decades. However, a lack of clear metrics and a shared approach to measuring the multiple components of sustainable diets has hindered progress toward generating the evidence needed to ensure the credibility of new guidelines. We performed a systematic literature review of empirical research studies on sustainable diets to identify the components of sustainability that were measured and the methods applied to do so. Two independent reviewers systematically searched 30 databases and other sources with the use of a uniform set of search terms and a priori exclusion criteria. In total, 113 empirical studies were included in the final review. Nearly all of the studies were focused on high-income countries. Although there was substantial heterogeneity in the components of sustainability measured, the estimated greenhouse gas emissions (GHGEs) of various dietary patterns were by far most commonly measured (n = 71 studies). Estimating the GHGEs of foods through various stages of production, use, and recycling with the use of the Life Cycle Assessment approach was the most common method applied to measure the environmental impacts of diets (n = 49 studies). Many components of sustainable diets identified in existing conceptual frameworks are disproportionately underrepresented in the empirical literature, as are studies that examine consumer demand for sustainable dietary alternatives. The emphasis in the literature on high-income countries also overlooks the production and dietary alternatives most relevant to low- and middle-income countries. We propose 3 methodological and measurement approaches that would both improve the global relevance of our understanding of sustainable diets and attend more completely to the existing multidimensional, multiscale conceptual framing of sustainable diets.

  13. Results of The Analysis of The Blood Beryllium Lymphocyte Proliferation Test Data From The Oak Ridge Y-12 Study

    Energy Technology Data Exchange (ETDEWEB)

    Frome, EL

    2001-12-18

    The potential hazards from exposure to beryllium or beryllium compounds in the workplace were first reported in the 1930s. The tritiated thymidine beryllium lymphocyte proliferation test (BeLPT) is an in vitro blood test that is widely used to screen beryllium exposed workers in the nuclear industry for sensitivity to beryllium. Newman [18] has discussed the clinical significance of the BeLPT and described a standard protocol that was developed in the late 1980s. Cell proliferation is measured by the incorporation of tritiated thymidine into dividing cells on two culture dates and using three concentrations of beryllium sulfate. Results are expressed as a ''stimulation index'' (SI) which is the ratio of the amount of tritiated thymidine (measured by beta counts) in the stimulated cells divided by the counts for the unstimulated cells on the same culture day. Several statistical methods for use in the routine analysis of the BeLPT were considered in the early 1990's by Frome et al. [7]. The least absolute values (LAV) method was recommended for routine analysis of the BeLPT. The purposes of this report are to further evaluate the LAV method using new data, and to describe a new method for identification of an abnormal or borderline test. This new statistical biological positive (SBP) method reflects the clinical judgment that (1) at least two SIs show a ''positive'' response to beryllium, and (2), that the maximum of the six SIs must exceed a cut point that is determined from a reference data set of normal individuals whose blood has been tested by the same method in the same serum. The new data is from the Y-12 facility in Oak Ridge and consist of 1080 worker and 33 nonexposed control BeLPTs (all tested in the same serum). Graphical results are presented to explain the statistical method, and the new SBP method is applied to the Y-12 group. The true positive rate and specificity of the new method were estimated to be 86

  14. Measures of Cultural Competence in Nurses: An Integrative Review

    Directory of Open Access Journals (Sweden)

    Collette Loftin

    2013-01-01

    Full Text Available Background. There is limited literature available identifying and describing the instruments that measure cultural competence in nursing students and nursing professionals. Design. An integrative review was undertaken to identify the characteristics common to these instruments, examine their psychometric properties, and identify the concepts these instruments are designed to measure. Method. There were eleven instruments identified that measure cultural competence in nursing. Of these eleven instruments, four had been thoroughly tested in either initial development or in subsequent testing, with developers providing extensive details of the testing. Results. The current literature identifies that the instruments to assess cultural competence in nurses and nursing students are self-administered and based on individuals' perceptions. The instruments are commonly utilized to test the effectiveness of educational programs designed to increase cultural competence. Conclusions. The reviewed instruments measure nurses’ self-perceptions or self-reported level of cultural competence but offer no objective measure of culturally competent care from a patient’s perspective which can be problematic. Comparison of instruments reveals that they are based on a variety of conceptual frameworks and that multiple factors should be considered when deciding which instrument to use.

  15. A Psychometric Review of Measures Assessing Discrimination Against Sexual Minorities.

    Science.gov (United States)

    Morrison, Todd G; Bishop, C J; Morrison, Melanie A; Parker-Taneo, Kandice

    2016-08-01

    Discrimination against sexual minorities is widespread and has deleterious consequences on victims' psychological and physical wellbeing. However, a review of the psychometric properties of instruments measuring lesbian, gay, and bisexual (LGB) discrimination has not been conducted. The results of this review, which involved evaluating 162 articles, reveal that most have suboptimal psychometric properties. Specifically, myriad scales possess questionable content validity as (1) items are not created in collaboration with sexual minorities; (2) measures possess a small number of items and, thus, may not sufficiently represent the domain of interest; and (3) scales are "adapted" from measures designed to examine race- and gender-based discrimination. Additional limitations include (1) summed scores are computed, often in the absence of scale score reliability metrics; (2) summed scores operate from the questionable assumption that diverse forms of discrimination are necessarily interrelated; (3) the dimensionality of instruments presumed to consist of subscales is seldom tested; (4) tests of criterion-related validity are routinely omitted; and (5) formal tests of measures' construct validity are seldom provided, necessitating that one infer validity based on the results obtained. The absence of "gold standard" measures, the attendant difficulty in formulating a coherent picture of this body of research, and suggestions for psychometric improvements are noted. PMID:26566991

  16. Proton irradiation effects on beryllium - A macroscopic assessment

    Science.gov (United States)

    Simos, Nikolaos; Elbakhshwan, Mohamed; Zhong, Zhong; Camino, Fernando

    2016-10-01

    Beryllium, due to its excellent neutron multiplication and moderation properties, in conjunction with its good thermal properties, is under consideration for use as plasma facing material in fusion reactors and as a very effective neutron reflector in fission reactors. While it is characterized by unique combination of structural, chemical, atomic number, and neutron absorption cross section it suffers, however, from irradiation generated transmutation gases such as helium and tritium which exhibit low solubility leading to supersaturation of the Be matrix and tend to precipitate into bubbles that coalesce and induce swelling and embrittlement thus degrading the metal and limiting its lifetime. Utilization of beryllium as a pion production low-Z target in high power proton accelerators has been sought both for its low Z and good thermal properties in an effort to mitigate thermos-mechanical shock that is expected to be induced under the multi-MW power demand. To assess irradiation-induced changes in the thermal and mechanical properties of Beryllium, a study focusing on proton irradiation damage effects has been undertaken using 200 MeV protons from the Brookhaven National Laboratory Linac and followed by a multi-faceted post-irradiation analysis that included the thermal and volumetric stability of irradiated beryllium, the stress-strain behavior and its ductility loss as a function of proton fluence and the effects of proton irradiation on the microstructure using synchrotron X-ray diffraction. The mimicking of high temperature irradiation of Beryllium via high temperature annealing schemes has been conducted as part of the post-irradiation study. This paper focuses on the thermal stability and mechanical property changes of the proton irradiated beryllium and presents results of the macroscopic property changes of Beryllium deduced from thermal and mechanical tests.

  17. Review of soot measurement in hydrocarbon-air flames

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Soot,which is produced in fuel-rich parts of flames as a result of incomplete combustion of hydrocarbons,is the No.2 contributor to global warming after carbon dioxide.Developing soot measurement techniques is important to understand soot formation mechanism and control soot emission.The various soot measurement techniques,such as thermophoretic sampling par-ticles diagnostics followed by electron microscopy analysis,thermocouple particle densitometry,light extinction,laser-induced incandescence,two-color method,and emission computed tomography,are reviewed in this paper.The measurement principle and application cases of these measurement methods are described in detail.The development trend of soot measurement is to realize the on-line measurement of multi-dimensional distributions of temperature,soot volume fraction,soot particle size and other parameters in hydrocarbon-air flames.Soot measurement techniques suitable for both small flames in laboratories and large-scale flames in industrial combustion devices should be developed.Besides,in some special situations,such as high-pressure,zero gravity and micro-gravity flames,soot measurement also should be provided.

  18. Tritium and helium retention and release from irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Anderl, R.A.; Longhurst, G.R.; Oates, M.A.; Pawelko, R.J. [Idaho National Engineering and Environmental Lab., Idaho Falls, ID (United States)

    1998-01-01

    This paper reports the results of an experimental effort to anneal irradiated beryllium specimens and characterize them for steam-chemical reactivity experiments. Fully-dense, consolidated powder metallurgy Be cylinders, irradiated in the EBR-II to a fast neutron (>0.1 MeV) fluence of {approx}6 x 10{sup 22} n/cm{sup 2}, were annealed at temperatures from 450degC to 1200degC. The releases of tritium and helium were measured during the heat-up phase and during the high-temperature anneals. These experiments revealed that, at 600degC and below, there was insignificant gas release. Tritium release at 700degC exhibited a delayed increase in the release rate, while the specimen was at 700degC. For anneal temperatures of 800degC and higher, tritium and helium release was concurrent and the release behavior was characterized by gas-burst peaks. Essentially all of the tritium and helium was released at temperatures of 1000degC and higher, whereas about 1/10 of the tritium was released during the anneals at 700degC and 800degC. Measurements were made to determine the bulk density, porosity and specific surface area for each specimen before and after annealing. These measurements indicated that annealing caused the irradiated Be to swell, by as much as 14% at 700degC and 56% at 1200degC. Kr gas adsorption measurements for samples annealed at 1000degC and 1200degC determined specific surface areas between 0.04 m{sup 2}/g and 0.1 m{sup 2}/g for these annealed specimens. The tritium and helium gas release measurements and the specific surface area measurements indicated that annealing of irradiated Be caused a porosity network to evolve and become surface-connected to relieve internal gas pressure. (author)

  19. Development of Interatomic Potentials for Beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Bjorkas, C.; Juslin, N.; Nordlund, K. [Accelerator Laboratory, University of Helsinki, P.O. Box 43, FIN-00014 Helsinki (Finland); Erhart, P. [Lawrence Livermore National Laboratory, Livermore, AK (United States); Henriksson, K. [Royal Institute of Technology, Stockholm (Sweden)

    2007-07-01

    Full text of publication follows: To be able to benefit from fusion as a clean and safe power source, we need a comprehensive understanding of the dynamic region of a fusion reactor. Knowing the interplay between the fuel plasma and the reactor components, such as the first wall and the divertor, one can minimize the resulting degradation. The atom-level mechanisms behind the reactions, (e.g. erosion and redeposition) are, however, not accessible to experiments. Hence, computational methods, including molecular dynamics (MD) simulations, are needed. The interactions in a system of particles are within MD described by an interatomic potential. The study of reactor processes requires models for the mixed interaction between the first wall and divertor materials beryllium, carbon and tungsten, as well as for the interaction of these with hydrogen. The absence of proper models for the Be system motivated us to develop potentials for pure Be, Be-C, Be-W and Be-H. We present a Tersoff-like bond order potential for pure Be and the same formalism applied to Be-C and Be-H. The performance of the potentials is discussed and an outlook for the remaining potential is also given. (authors)

  20. Beryllium abundances in stars hosting giant planets

    CERN Document Server

    Santos, N C; Israelian, G; Mayor, M; Rebolo, R; García-Gíl, A; Pérez de Taoro, M R; Randich, S

    2002-01-01

    We have derived beryllium abundances in a wide sample of stars hosting planets, with spectral types in the range F7V-K0V, aimed at studying in detail the effects of the presence of planets on the structure and evolution of the associated stars. Predictions from current models are compared with the derived abundances and suggestions are provided to explain the observed inconsistencies. We show that while still not clear, the results suggest that theoretical models may have to be revised for stars with Teff<5500K. On the other hand, a comparison between planet host and non-planet host stars shows no clear difference between both populations. Although preliminary, this result favors a ``primordial'' origin for the metallicity ``excess'' observed for the planetary host stars. Under this assumption, i.e. that there would be no differences between stars with and without giant planets, the light element depletion pattern of our sample of stars may also be used to further investigate and constraint Li and Be deple...

  1. Post irradiation examination and evaluation of properties of beryllium assemblies in HFETR

    International Nuclear Information System (INIS)

    The post irradiation examination of the beryllium assemblies and irradiated surveillance Be specimens in HFETR are described. The nondestructive test of nine Be assemblies are carried out underwater in the storage pool of HFETR. Dimension and density of the irradiated surveillance specimens are also measured in semi-hot cells. The evaluation on irradiation behavior of Be based on the results from the tests indicates that the home made Be has good performances against irradiation and corrosion, the design of HFETR Be assemblies are reasonable and the management of the core Be assemblies is scientific. Some suggestions for measures on Be irradiation surveillance have been proposed. (authors)

  2. The structure, properties and performance of plasma-sprayed beryllium for fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R.G.; Stanek, P.W.; Elliott, K.E. [and others

    1995-09-01

    Plasma-spray technology is under investigation as a method for producing high thermal conductivity beryllium coatings for use in magnetic fusion applications. Recent investigations have focused on optimizing the plasma-spray process for depositing beryllium coatings on damaged beryllium surfaces. Of particular interest has been optimizing the processing parameters to maximize the through-thickness thermal conductivity of the beryllium coatings. Experimental results will be reported on the use of secondary H{sub 2} gas additions to improve the melting of the beryllium powder and transferred-arc cleaning to improve the bonding between the beryllium coatings and the underlying surface. Information will also be presented on thermal fatigue tests which were done on beryllium coated ISX-B beryllium limiter tiles using 10 sec cycle times with 60 sec cooldowns and an International Thermonuclear Experimental Reactor (ITER) relevant divertor heat flux slightly in excess of 5 MW/m{sup 2}.

  3. Controlling Beryllium Contaminated Material And Equipment For The Building 9201-5 Legacy Material Disposition Project

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, T. D.; Easterling, S. D.

    2010-10-01

    This position paper addresses the management of beryllium contamination on legacy waste. The goal of the beryllium management program is to protect human health and the environment by preventing the release of beryllium through controlling surface contamination. Studies have shown by controlling beryllium surface contamination, potential airborne contamination is reduced or eliminated. Although there are areas in Building 9201-5 that are contaminated with radioactive materials and mercury, only beryllium contamination is addressed in this management plan. The overall goal of this initiative is the compliant packaging and disposal of beryllium waste from the 9201-5 Legacy Material Removal (LMR) Project to ensure that beryllium surface contamination and any potential airborne release of beryllium is controlled to levels as low as practicable in accordance with 10 CFR 850.25.

  4. Validation of cleaning method for various parts fabricated at a Beryllium facility

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Cynthia M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-15

    This study evaluated and documented a cleaning process that is used to clean parts that are fabricated at a beryllium facility at Los Alamos National Laboratory. The purpose of evaluating this cleaning process was to validate and approve it for future use to assure beryllium surface levels are below the Department of Energy’s release limits without the need to sample all parts leaving the facility. Inhaling or coming in contact with beryllium can cause an immune response that can result in an individual becoming sensitized to beryllium, which can then lead to a disease of the lungs called chronic beryllium disease, and possibly lung cancer. Thirty aluminum and thirty stainless steel parts were fabricated on a lathe in the beryllium facility, as well as thirty-two beryllium parts, for the purpose of testing a parts cleaning method that involved the use of ultrasonic cleaners. A cleaning method was created, documented, validated, and approved, to reduce beryllium contamination.

  5. A REVIEW OF COLOR MEASURMENTS IN THE TEXTILE INDUSTRY

    Directory of Open Access Journals (Sweden)

    BRAD Raluca

    2016-05-01

    Full Text Available Color is an important factor in the evaluation of aesthetic appearance and functionality of many products, but especially of textile industry ones. In textiles production process, color can be assessed in different stages: the selection of raw materials, the incoming item tests, the preparation of dyeing ingredients, the crocking resistance testing, the color fastness and in all stages, the quality control. Color evaluation can be done visually or using specialized test instruments such as colorimeters or spectrometers, therefore a high accuracy of measurements must be achieved. Standards describe different procedures and testing techniques depending on the product type and the quality level required by the customer. The paper presents the most common systems of color representation and communication, measurement methods and techniques, and standards that define them. The CIE color representation systems have been reviewed, together with the measurement methods offering the repeatability of the process. Most of the standards have been issued in US, but several European and International are stating the color assessment process. We have also conducted a review of latest published papers in the topic of color measurement, comparison and match. Several image processing applications algorithms offers new opportunities for computer assisted evaluation and control of textile color properties.

  6. Electric properties of the Beryllium-11 system in Halo EFT

    International Nuclear Information System (INIS)

    We compute E1 transitions and electric radii in the Beryllium-11 nucleus using an effective field theory that exploits the separation of scales in this halo system. We fix the leading-order parameters of the EFT from measured data on the 1/2+ and 1/2- levels in 11Be and the B(E1) strength for the transition between them. We then obtain predictions for the B(E1) strength for Coulomb dissociation of the 11Be nucleus to the continuum. We also compute the charge radii of the 1/2+ and 1/2- states. Agreement with experiment within the expected accuracy of a leading-order computation in this EFT is obtained. We also discuss how next-to-leading-order (NLO) corrections involving both s-wave and p-wave 10Be-neutron interactions affect our results, and display the NLO predictions for quantities which are free of additional short-distance operators at this order. Information on neutron-10Be scattering in the relevant channels is inferred.

  7. A Report on the Validation of Beryllium Strength Models

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Derek Elswick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-02-05

    This report discusses work on validating beryllium strength models with flyer plate and Taylor rod experimental data. Strength models are calibrated with Hopkinson bar and quasi-static data. The Hopkinson bar data for beryllium provides strain rates up to about 4000 per second. A limitation of the Hopkinson bar data for beryllium is that it only provides information on strain up to about 0.15. The lack of high strain data at high strain rates makes it difficult to distinguish between various strength model settings. The PTW model has been calibrated many different times over the last 12 years. The lack of high strain data for high strain rates has resulted in these calibrated PTW models for beryllium exhibiting significantly different behavior when extrapolated to high strain. For beryllium, the α parameter of PTW has recently been calibrated to high precision shear modulus data. In the past the α value for beryllium was set based on expert judgment. The new α value for beryllium was used in a calibration of the beryllium PTW model by Sky Sjue. The calibration by Sjue used EOS table information to model the temperature dependence of the heat capacity. Also, the calibration by Sjue used EOS table information to model the density changes of the beryllium sample during the Hopkinson bar and quasi-static experiments. In this paper, the calibrated PTW model by Sjue is compared against experimental data and other strength models. The other strength models being considered are a PTW model calibrated by Shuh- Rong Chen and a Steinberg-Guinan type model by John Pedicini. The three strength models are used in a comparison against flyer plate and Taylor rod data. The results show that the Chen PTW model provides better agreement to this data. The Chen PTW model settings have been previously adjusted to provide a better fit to flyer plate data, whereas the Sjue PTW model has not been changed based on flyer plate data. However, the Sjue model provides a reasonable fit to

  8. Quality of life measurement in bone metastases: A literature review

    Directory of Open Access Journals (Sweden)

    Sukirtha Tharmalingam

    2008-12-01

    Full Text Available Sukirtha Tharmalingam, Edward Chow, Kristin Harris, Amanda Hird, Emily SinclairRapid Response Radiotherapy Program, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, CanadaAbstract: Quality of life (QOL has become an important consideration in the care of patients with bone metastases as prevalence, incidence and patient survival are on the rise. As a result, more interventional studies now measure patient’s QOL as a meaningful endpoint. However, well-developed bone metastases specific quality of life instruments are lacking. A literature review was conducted to better understand the nature of QOL instruments used in bone metastases trials. A total of 47 articles evaluating QOL in patients with bone metastases were identified. Twenty-five different instruments were used to evaluate QOL with study-designed questionnaires and the EORTC QLQ-C30 being most commonly employed. Many studies used more than one scale or instrument to measure QOL. This makes it difficult to compare QOL in bone metastases patients across studies and come to any formal conclusions. Therefore, this review demonstrates the need to develop a bone module that can be used across countries in future clinical trials.Keywords: bone metastases, quality of life, QOL instrument, review

  9. The results of medical surveillance of beryllium production personnel

    International Nuclear Information System (INIS)

    The report presents results of surveillance of 1836 workers of beryllium production of Ulba Metallurgical Plant JSC with the acute and chronic forms of occupation diseases for 52 years of its operation. The dependence of acute and chronic occupation lesions on the protection degree is shown. It has been found out that, the risk of getting an occupation disease increases sharply at the moments of experimental works and at the time of reconstruction and some other extreme conditions in the production, that is supported by fixed lesions of eye mucous coat, skin and lung lesions. In this case, the readiness of people for their work in deleterious conditions and their personal responsibility for following the regulations of safety occupational standards plays a definite role. Therefore, the issues of protection are of paramount importance in prophylaxis both of acute and chronic exposure to beryllium. An influence of duration of service and occupation on chronic beryllium diseases is shown. A parallel between the lung beryllium disease and skin lesions by insoluble beryllium compounds is drawn for the first time. (author)

  10. Report of a technical evaluation panel on the use of beryllium for ITER plasma facing material and blanket breeder material

    International Nuclear Information System (INIS)

    Beryllium because of its low atomic number and high thermal conductivity, is a candidate for both ITER first wall and divertor surfaces. This study addresses the following: why beryllium; design requirements for the ITER divertor; beryllium supply and unirradiated physical/mechanical property database; effects of irradiation on beryllium properties; tritium issues; beryllium health and safety; beryllium-coolant interactions and safety; thermal and mechanical tests; plasma erosion of beryllium; recommended beryllium grades for ITER plasma facing components; proposed manufacturing methods to produce beryllium parts for ITER; emerging beryllium materials; proposed inspection and maintenance techniques for beryllium components and coatings; time table and costs; and the importance of integrating materials and manufacturing personnel with designers

  11. Report of a technical evaluation panel on the use of beryllium for ITER plasma facing material and blanket breeder material

    Energy Technology Data Exchange (ETDEWEB)

    Ulrickson, M.A. [ed.] [Sandia National Labs., Albuquerque, NM (United States); Manly, W.D. [Oak Ridge National Lab., TN (United States); Dombrowski, D.E. [Brush Wellman, Inc., Cleveland, OH (United States)] [and others

    1995-08-01

    Beryllium because of its low atomic number and high thermal conductivity, is a candidate for both ITER first wall and divertor surfaces. This study addresses the following: why beryllium; design requirements for the ITER divertor; beryllium supply and unirradiated physical/mechanical property database; effects of irradiation on beryllium properties; tritium issues; beryllium health and safety; beryllium-coolant interactions and safety; thermal and mechanical tests; plasma erosion of beryllium; recommended beryllium grades for ITER plasma facing components; proposed manufacturing methods to produce beryllium parts for ITER; emerging beryllium materials; proposed inspection and maintenance techniques for beryllium components and coatings; time table and costs; and the importance of integrating materials and manufacturing personnel with designers.

  12. Etched track radiometers in radon measurements: a review

    CERN Document Server

    Nikolaev, V A

    1999-01-01

    Passive radon radiometers, based on alpha particle etched track detectors, are very attractive for the assessment of radon exposure. The present review considers various devices used for measurement of the volume activity of radon isotopes and their daughters and determination of equilibrium coefficients. Such devices can be classified into 8 groups: (i) open or 'bare' detectors, (ii) open chambers, (iii) sup 2 sup 2 sup 2 Rn chambers with an inlet filter, (iv) advanced sup 2 sup 2 sup 2 Rn radiometers, (v) multipurpose radiometers, (vi) radiometers based on a combination of etched track detectors and an electrostatic field, (vii) radiometers based on etched track detectors and activated charcoal and (viii) devices for the measurement of radon isotopes and/or radon daughters by means of track parameter measurements. Some of them such as the open detector and the chamber with an inlet filter have a variety of modifications and are applied widely both in geophysical research and radon dosimetric surveys. At the...

  13. Experimental studies and modeling of processes of hydrogen isotopes interaction with beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Tazhibaeva, I.L.; Chikhray, Y.V.; Romanenko, O.G.; Klepikov, A.Kh.; Shestakov, V.P.; Kulsartov, T.V. [Science Research Inst. of Experimental and Theoretical Physics of Kazakh State Univ., Almaty (Kazakhstan); Kenzhin, E.A.

    1998-01-01

    The objective of this work was to clarify the surface beryllium oxide influence on hydrogen-beryllium interaction characteristics. Analysis of experimental data and modeling of processes of hydrogen isotopes accumulation, diffusion and release from neutron irradiated beryllium was used to achieve this purpose as well as the investigations of the changes of beryllium surface element composition being treated by H{sup +} and Ar{sup +} plasma glowing discharge. (author)

  14. Satisfaction measurement instruments for healthcare service users: a systematic review.

    Science.gov (United States)

    Almeida, Renato Santos de; Bourliataux-Lajoinie, Stephane; Martins, Mônica

    2015-01-01

    Patient satisfaction surveys can be an interesting way to improve quality and discuss the concept of patient-centered care. This study aimed to conduct a systematic review of the validated patient satisfaction measurement instruments applied in healthcare. The systematic review searched the MEDLINE/PubMed, LILACS, SciELO, Scopus and Web of Knowledge. The search strategy used the terms: "Patient Satisfaction" AND "Patient centered care" AND "Healthcare survey OR Satisfaction questionnaire" AND "Psychometric properties". 37 studies were included and almost all studies showed that satisfaction is a multidimensional construct. In these studies, 34 different instruments were used and most surveys contained the dimension patient-healthcare professional interactions, physical environment and management process. The COSMIN score for methodological quality showed that most of them scored a good or fair average. We can conclude that there is not a gold standard instrument for patient satisfaction assessment but some dimensions are essential for this construct. PMID:25715288

  15. Satisfaction measurement instruments for healthcare service users: a systematic review

    Directory of Open Access Journals (Sweden)

    Renato Santos de Almeida

    2015-01-01

    Full Text Available Patient satisfaction surveys can be an interesting way to improve quality and discuss the concept of patient-centered care. This study aimed to conduct a systematic review of the validated patient satisfaction measurement instruments applied in healthcare. The systematic review searched the MEDLINE/PubMed, LILACS, SciELO, Scopus and Web of Knowledge. The search strategy used the terms: "Patient Satisfaction" AND "Patient centered care" AND "Healthcare survey OR Satisfaction questionnaire" AND "Psychometric properties". 37 studies were included and almost all studies showed that satisfaction is a multidimensional construct. In these studies, 34 different instruments were used and most surveys contained the dimension patient-healthcare professional interactions, physical environment and management process. The COSMIN score for methodological quality showed that most of them scored a good or fair average. We can conclude that there is not a gold standard instrument for patient satisfaction assessment but some dimensions are essential for this construct.

  16. Lawrence Livermore Laboratory's beryllium control program for high-explosive test firing bunkers and tables

    International Nuclear Information System (INIS)

    This report on the control program to minimize beryllium levels in Laboratory workplaces includes an outline of beryllium surface, soil, and air levels and an 11-y summary of sampling results from two high-use, high-explosive test firing bunkers. These sampling data and other studies demonstrate that the beryllium control program is functioning effectively

  17. Beryllium Health and Safety Committee Data Reporting Task Force White Paper #2 -- Uses of Uncensored Data

    Energy Technology Data Exchange (ETDEWEB)

    MacQueen, D H

    2007-10-10

    TS was a suggestion that certain of the statistical comparisons described in the TS could be better implemented if analytical results, even when below a reporting limit, were to be reported by analytical laboratories. See Appendix 1 for a review of terminology related to reporting limits. The Beryllium Health and Safety Committee (BHSC) formed a Sampling and Analysis Subcommittee (SAS) in 2003. The SAS established a working group on accreditation and reporting limits. By 2006 it had become evident that the issues extended to data reporting as a whole. The SAS proposed to the BHSC the formation of a Data Reporting Task Force (DRTF) to consider issues related to data reporting. The BHSC Board agreed, and requested that the DRTF generate a white paper, to be offered by the BHSC to potential interested parties such as the DOE policy office that is responsible for beryllium health and safety policy. It was noted that additional products could include detailed guidance and potentially a journal article in the future. The SAS proposed that DRTF membership represent the affected disciplines (chemists, industrial hygiene professionals and statisticians, and the DOE office that is responsible for beryllium health and safety policy). The BHSC Board decided that DRTF membership should come from DOE sites, since the focus would be on reporting in the context of the TS and the Rule. The DRTF came into existence in late 2006. The DRTF membership includes industrial hygienists, analytical chemists and laboratory managers, members of the regulatory and oversight community, and environmental statisticians. A first White Paper, ''Summary of Issues and Path Forward'', was reviewed by the BHSC in March 2007 and issued by the DRTF in June 2007. It describes the charter of the DRTF, introduces some basic terminology (reproduced here in Appendix 1), lays out the issues the DRTF is expected to address, and describes a path forward for the DRTF's work. This first

  18. Estimation of beryllium ground state energy by Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kabir, K. M. Ariful [Department of Physical Sciences, School of Engineering and Computer Science, Independent University, Bangladesh (IUB) Dhaka (Bangladesh); Halder, Amal [Department of Mathematics, University of Dhaka Dhaka (Bangladesh)

    2015-05-15

    Quantum Monte Carlo method represent a powerful and broadly applicable computational tool for finding very accurate solution of the stationary Schrödinger equation for atoms, molecules, solids and a variety of model systems. Using variational Monte Carlo method we have calculated the ground state energy of the Beryllium atom. Our calculation are based on using a modified four parameters trial wave function which leads to good result comparing with the few parameters trial wave functions presented before. Based on random Numbers we can generate a large sample of electron locations to estimate the ground state energy of Beryllium. Our calculation gives good estimation for the ground state energy of the Beryllium atom comparing with the corresponding exact data.

  19. Photochemical Behavior of Beryllium Complexes with Subporphyrazines and Subphthalocyanines.

    Science.gov (United States)

    Montero-Campillo, M Merced; Lamsabhi, Al Mokhtar; Mó, Otilia; Yáñez, Manuel

    2016-07-14

    Structures of beryllium subphthalocyanines and beryllium subporphyrazines complexes with different substituents are explored for the first time. Their photochemical properties are studied using time-dependent density functional theory calculations and compared to boron-related compounds for which their photochemical activity is already known. These beryllium compounds were found to be thermodynamically stable in a vacuum and present features similar to those of boron-containing analogues, although the nature of bonding between the cation and the macrocycle presents subtle differences. Most important contributions to the main peak in the Q-band region arise from HOMO to LUMO transitions in the case of subphthalocyanines and alkyl subporphyrazine complexes, whereas a mixture of that contribution and a HOMO-2 to LUMO contribution are present in the case of thioalkyl subporphyrazines. The absorption in the visible region could make these candidates suitable for photochemical devices if combined with appropriate donor groups. PMID:26812068

  20. Force-field parameters for beryllium complexes in amorphous layers.

    Science.gov (United States)

    Emelyanova, Svetlana; Chashchikhin, Vladimir; Bagaturyants, Alexander

    2016-09-01

    Unknown force-field parameters for metal organic beryllium complexes used in emitting and electron transporting layers of OLED structures are determined. These parameters can be used for the predictive atomistic simulations of the structure and properties of amorphous organic layers containing beryllium complexes. The parameters are found for the AMBER force field using a relaxed scan procedure and quantum-mechanical DFT calculations of potential energy curves for specific internal (angular) coordinates in a series of three Be complexes (Bebq2; Be(4-mpp)2; Bepp2). The obtained parameters are verified in calculations of some molecular and crystal structures available from either quantum-mechanical DFT calculations or experimental data. Graphical Abstract Beryllium complexes in amorphous layersᅟ. PMID:27550375

  1. Monte Carlo uncertainty analyses for integral beryllium experiments

    CERN Document Server

    Fischer, U; Tsige-Tamirat, H

    2000-01-01

    The novel Monte Carlo technique for calculating point detector sensitivities has been applied to two representative beryllium transmission experiments with the objective to investigate the sensitivity of important responses such as the neutron multiplication and to assess the related uncertainties due to the underlying cross-section data uncertainties. As an important result, it has been revealed that the neutron multiplication power of beryllium can be predicted with good accuracy using state-of-the-art nuclear data evaluations. Severe discrepancies do exist for the spectral neutron flux distribution that would transmit into significant uncertainties of the calculated neutron spectra and of the nuclear blanket performance in blanket design calculations. With regard to this, it is suggested to re-analyse the secondary energy and angle distribution data of beryllium by means of Monte Carlo based sensitivity and uncertainty calculations. Related code development work is underway.

  2. Clustering Measurements of broad-line AGNs: Review and Future

    CERN Document Server

    Krumpe, Mirko; Coil, Alison L

    2013-01-01

    Despite substantial effort, the precise physical processes that lead to the growth of super-massive black holes in the centers of galaxies are still not well understood. These phases of black hole growth are thought to be of key importance in understanding galaxy evolution. Forthcoming missions such as eROSITA, HETDEX, eBOSS, BigBOSS, LSST, and Pan-STARRS will compile by far the largest ever Active Galactic Nuclei (AGNs) catalogs which will allow us to measure the spatial distribution of AGNs in the universe with unprecedented accuracy. For the first time, AGN clustering measurements will reach a level of precision that will not only allow for an alternative approach to answering open questions in AGN/galaxy co-evolution but will open a new frontier, allowing us to precisely determine cosmological parameters. This paper reviews the large-scale clustering measurements of broad line AGNs. We summarize how clustering is measured and which constraints can be derived from AGN clustering measurements, we discuss re...

  3. Residual limb volume change: Systematic review of measurement and management

    Directory of Open Access Journals (Sweden)

    Joan E. Sanders, PhD

    2011-10-01

    Full Text Available Management of residual limb volume affects decisions regarding timing of fit of the first prosthesis, when a new prosthetic socket is needed, design of a prosthetic socket, and prescription of accommodation strategies for daily volume fluctuations. This systematic review assesses what is known about measurement and management of residual limb volume change in persons with lower-limb amputation. Publications that met inclusion criteria were grouped into three categories: group I: descriptions of residual limb volume measurement techniques; group II: studies investigating the effect of residual limb volume change on clinical care in people with lower-limb amputation; and group III: studies of residual limb volume management techniques or descriptions of techniques for accommodating or controlling residual limb volume. We found that many techniques for the measurement of residual limb volume have been described but clinical use is limited largely because current techniques lack adequate resolution and in-socket measurement capability. Overall, limited evidence exists regarding the management of residual limb volume, and the evidence available focuses primarily on adults with transtibial amputation in the early postoperative phase. While we can draw some insights from the available research about residual limb volume measurement and management, further research is required.

  4. ESA-SSA Review of Space Weather Measurement Requirements

    Science.gov (United States)

    Luntama, Juha-Pekka; Glover, Alexi; Hilgers, Alain

    2012-07-01

    The ESA Space Situational Awareness (SSA) Preparatory Programme was started in 2009. The objective of the programme is to support the European independent utilisation of and access to space. The first phase of the ESA SSA system development will be finished in 2012 and the next phase is foreseen to be started after the ESA Ministerial Council meeting in November 2012. The definition of measurement requirements for the Space Weather Segment (SWE) of the ESA SSA system has been based on the space weather service requirements defined the by expected users of the system. This document, SSA SWE Customer Requirements Document (CRD), has been defined in a iterative process together with the members of the SSA User Representative Group (URG) and the delegates representing the European states participating the programme. Based on the SWE CRD, ESA with the support of the European industry has produced two documents: SSA SWE System Requirements Document (SRD) and SSA SWE Product Specification (PS). SWE PS contains the requirements for the measurements data required by the SSA SWE system. The SWE PS document has been recently rigorously reviewed by the SSA URG in the framework of the SSA System Requirements Review (SRR). The support provided by the Steering Board of the ESA Space Weather Working Team (SWWT) in this review was extremely useful. The members of the SWWT SB representing the scientific community and the provisional service providers were able to give very detailed comments regarding the measurement requirements for accuracy, cadence, timeliness, etc. As these parameters will be provisional design and cost drivers for the ESA SSA system, definition of the appropriate values at this point in the programme is crucial. This paper provides an overview of the measurement requirements for the SWE Segment of the ESA SSA Programme. The paper discusses the requirement definition process, the customer and service provider inputs, and the critical requirements as they have

  5. CHAPTER 7. BERYLLIUM ANALYSIS BY NON-PLASMA BASED METHODS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A

    2009-04-20

    The most common method of analysis for beryllium is inductively coupled plasma atomic emission spectrometry (ICP-AES). This method, along with inductively coupled plasma mass spectrometry (ICP-MS), is discussed in Chapter 6. However, other methods exist and have been used for different applications. These methods include spectroscopic, chromatographic, colorimetric, and electrochemical. This chapter provides an overview of beryllium analysis methods other than plasma spectrometry (inductively coupled plasma atomic emission spectrometry or mass spectrometry). The basic methods, detection limits and interferences are described. Specific applications from the literature are also presented.

  6. A Review of Direct Neck Measurement in Occupational Settings

    Directory of Open Access Journals (Sweden)

    Helenice J. C. Gil Coury

    2010-12-01

    Full Text Available No guidelines are available to orient researchers on the availability and applications of equipment and sensors for recording precise neck movements in occupational settings. In this study reports on direct measurements of neck movements in the workplace were reviewed. Using relevant keywords two independent reviewers searched for eligible studies in the following databases: Cinahal, Cochrane, Embase, Lilacs, PubMed, MEDLINE, PEDro, Scopus and Web of Science. After applying the inclusion criteria, 13 articles on direct neck measurements in occupational settings were retrieved from among 33,666 initial titles. These studies were then methodologically evaluated according to their design characteristics, exposure and outcome assessment, and statistical analysis. The results showed that in most of the studies the three axes of neck movement (flexion-extension, lateral flexion and rotation were not simultaneously recorded. Deficiencies in available equipment explain this flaw, demonstrating that sensors and systems need to be improved so that a true understanding of real occupational exposure can be achieved. Further studies are also needed to assess neck movement in those who perform heavy-duty work, such as nurses and electricians, since no report about such jobs was identified.

  7. Pion yield from 450 GeV/c protons on beryllium

    CERN Document Server

    Ambrosini, G; Bernier, K; Biino, C; Bonesini, M; Bonivento, W; Borer, K; Brooijmans, G; Catanesi, M G; Collazuol, G; Daniels, D C; Dittus, F B; Elsener, K; Godley, A; Grant, A; Grégoire, G; Guglielmi, A M; Kabana, S; Klingenberg, R; Lehmann, G; Lindén, T; Linssen, Lucie; Marchionni, A; Mishra, S R; Moffitt, L; Moser, U; Palladino, Vittorio; Pietropaolo, F; Pretzl, Klaus P; Pullia, Antonio; Radicioni, E; Ragazzi, S; Schacher, J; Sergiampietri, F; Soler, F J P; Stoffel, F; Tabarelli de Fatis, T; Terranova, F; Tovey, Stuart N; Tsesmelis, E; Weber, M

    1998-01-01

    This paper reports on the charged pion production yields measured by the SPY/NA56 experiment for 450 GeV/c proton interactions on beryllium targets. The present data cover a secondary momentum range from 7 GeV/c to 135 GeV/c in the forward direction. An experimental accuracy ranging from 5 to 10\\%, depending on the beam momentum, has been achieved, limited mainly by the knowledge of the beam acceptance. These results will be relevant in the calculation of neutrino fluxes in present and future neutrino beams.

  8. K/π production ratios from 450 GeV/c protons on beryllium

    Science.gov (United States)

    Spy Collaboration; Ambrosini, G.; Arsenescu, R.; Bernier, K.; Biino, C.; Bonesini, M.; Bonivento, W.; Borer, K.; Brooijmans, G.; Catanesi, M. G.; Collazuol, G.; Daniels, D.; Dittus, F.; Elsener, K.; Godley, A.; Grant, A.; Gregoire, G.; Guglielmi, A.; Kabana, S.; Klingenberg, R.; Lehmann, G.; Lindén, T.; Linssen, L.; Marchionni, A.; Mishra, S. R.; Moffitt, L.; Moser, U.; Palladino, V.; Pietropaolo, F.; Pretzl, K.; Pullia, A.; Radicioni, E.; Ragazzi, S.; Schacher, J.; Sergiampietri, F.; Soler, F. J. P.; Stoffel, F.; Tabarelli de Fatis, T.; Terranova, F.; Tovey, S. N.; Tsesmelis, E.; Weber, M.

    1998-02-01

    This paper reports on the charged K/π production ratios and on the shape of the pT distributions of π fluxes measured by the SPY/NA56 experiment for 450 GeV/c proton interactions on beryllium targets. The present data cover a secondary momentum range from 7 GeV/c to 135 GeV/c in the forward direction and with pT values up to 600 MeV/c. An experimental accuracy of about 3% has been achieved. These results will reduce the uncertainty on the estimation of the νe component of neutrino beams.

  9. Pion yield from 450 GeV/c protons on beryllium

    Science.gov (United States)

    Spy Collaboration; Ambrosini, G.; Arsenescu, R.; Bernier, K.; Biino, C.; Bonesini, M.; Bonivento, W.; Borer, K.; Brooijmans, G.; Catanesi, M. G.; Collazuol, G.; Daniels, D.; Dittus, F.; Elsener, K.; Godley, A.; Grant, A.; Gregoire, G.; Guglielmi, A.; Kabana, S.; Klingenberg, R.; Lehmann, G.; Lindén, T.; Linssen, L.; Marchionni, A.; Mishra, S. R.; Moffitt, L.; Moser, U.; Palladino, V.; Pietropaolo, F.; Pretzl, K.; Pullia, A.; Radicioni, E.; Ragazzi, S.; Schacher, J.; Sergiampietri, F.; Soler, F. J. P.; Stoffel, F.; Tabarelli de Fatis, T.; Terranova, F.; Tovey, S. N.; Tsesmelis, E.; Weber, M.

    1998-04-01

    This paper reports on the charged pion production yields measured by the SPY/NA56 experiment for 450 GeV/c proton interactions on beryllium targets. The present data cover a secondary momentum range from 7 GeV/c to 135 GeV/c in the forward direction. An experimental accuracy ranging from 5 to 10%, depending on the beam momentum, has been achieved, limited mainly by the knowledge of the beam acceptance. These results will be relevant in the calculation of neutrino fluxes in present and future neutrino beams.

  10. Thermal shock tests with beryllium coupons in the electron beam facility JUDITH

    Energy Technology Data Exchange (ETDEWEB)

    Roedig, M.; Duwe, R.; Schuster, J.L.A. [Forschungszentrum Juelich GmbH (Germany)] [and others

    1995-09-01

    Several grades of American and Russian beryllium have been tested in high heat flux tests by means of an electron beam facility. For safety reasons, major modifications of the facility had to be fulfilled in advance to the tests. The influence of energy densities has been investigated in the range between 1 and 7 MJ/m{sup 2}. In addition the influence of an increasing number of shots at constant energy density has been studied. For all samples, surface profiles have been measured before and after the experiments. Additional information has been gained from scanning electron microscopy, and from metallography.

  11. Beryllium solubility in occupational airborne particles: Sequential extraction procedure and workplace application.

    Science.gov (United States)

    Rousset, Davy; Durand, Thibaut

    2016-01-01

    Modification of an existing sequential extraction procedure for inorganic beryllium species in the particulate matter of emissions and in working areas is described. The speciation protocol was adapted to carry out beryllium extraction in closed-face cassette sampler to take wall deposits into account. This four-step sequential extraction procedure aims to separate beryllium salts, metal, and oxides from airborne particles for individual quantification. Characterization of the beryllium species according to their solubility in air samples may provide information relative to toxicity, which is potentially related to the different beryllium chemical forms. Beryllium salts (BeF(2), BeSO(4)), metallic beryllium (Bemet), and beryllium oxide (BeO) were first individually tested, and then tested in mixtures. Cassettes were spiked with these species and recovery rates were calculated. Quantitative analyses with matched matrix were performed using inductively coupled plasma mass spectrometry (ICP-MS). Method Detection Limits (MDLs) were calculated for the four matrices used in the different extraction steps. In all cases, the MDL was below 4.2 ng/sample. This method is appropriate for assessing occupational exposure to beryllium as the lowest recommended threshold limit values are 0.01 µg.m(-3) in France([) (1) (]) and 0.05 µg.m(-3) in the USA.([ 2 ]) The protocol was then tested on samples from French factories where occupational beryllium exposure was suspected. Beryllium solubility was variable between factories and among the same workplace between different tasks. PMID:26327570

  12. Measuring verbal psychotherapeutic techniques – A systematic review of intervention characteristics and measures

    Directory of Open Access Journals (Sweden)

    Antje eGumz

    2015-11-01

    Full Text Available Language is one of the most important tools of psychotherapists. The working mechanisms of verbal therapeutic techniques, however, are still marginally understood. In part, this is due to the lack of a generally acknowledged typology as well as a gold standard for the assess-ment of verbal techniques, which limits the possibility of conducting studies focusing this topic. The present study reviews measures used in clinical research which assess directly ob-servable dimensions of verbal interventions in a reliable manner. All measures were evaluated with respect to their theoretical foundation, research goals, assessment modes, and various psychometric properties. A systematic search in databases (PubMed, PsycInfo, PsycArticles, PSYNDEX, Web of Science, Embase followed by an additional snowballing search cover-ing the years 1940-2013 yielded n=179 publications eligible for review. Within these publica-tions, 34 measures were identified showing great heterogeneity regarding the aspects under study. Only two measures reached the highest psychometric standards and can be recom-mended for clinical use without any reservation. Central problems include deficiencies in the systematization of techniques as well as their partly ambiguous and inconsistent definitions. To promote this field of research, it will be important to achieve a consensus concerning the terminology, conceptions and measures of verbal techniques.

  13. Some features of beryllium corrosion behavior in Be-liquid Li-V-4Ti-4Cr alloy system

    International Nuclear Information System (INIS)

    Recent experimental results on beryllium corrosion behavior in a V-4Ti-4Cr alloy, liquid lithium static system during testing for 200-500 h at temperatures from 600 to 800 deg. C are presented. The influence of test conditions (temperature, duration and lithium purity) and beryllium characteristics (microstructure, grain size and chemical composition) on weight loss of beryllium and penetration of lithium into beryllium are discussed. Results of compressive tests for beryllium specimens before and after corrosion testing are also introduced

  14. Top-quark mass measurements: review and perspectives

    CERN Document Server

    Cortiana, Giorgio

    2015-01-01

    The top quark is the heaviest elementary particle known and its mass ($m_{\\rm top}$) is a fundamental parameter of the Standard Model (SM). The $m_{\\rm top}$ value affects theory predictions of particle production cross-sections required for exploring Higgs-boson properties and searching for New Physics (NP). Its precise determination is essential for testing the overall consistency of the SM, to constrain NP models, through precision electroweak fits, and has an extraordinary impact on the Higgs sector, and on the SM extrapolation to high-energies. The methodologies, the results, and the main theoretical and experimental challenges related to the $m_{\\rm top}$ measurements and combinations at the Large Hadron Collider (LHC) and at the Tevatron are reviewed and discussed. Finally, the prospects for the improvement of the $m_{\\rm top}$ precision during the upcoming LHC runs are briefly outlined.

  15. REVIEW OF HIGH FIELD Q SLOPE, CAVITY MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Gianluigi Ciovati

    2008-01-23

    One of the most interesting phenomenon occurring in superconducting radio-frequency (SRF) cavities made of bulk niobium is represented by a sharp decrease of the quality factor above peak surface magnetic field of about 90 mT and is referred to as "high field Q-slope" or "Q-drop". This phenomenon was observed first in 1997 and since then some effort was devoted to the understanding of the causes behind it. Still, no clear physical interpretation of the Q-drop has emerged, despite several attempts. In this contribution, I will review the experimental results for various cavities measured in many laboratories and I will try to identify common features and differences related to the Q-drop.

  16. Review of B0-B0 oscillation measurements

    International Nuclear Information System (INIS)

    Recent new measurements of the B0d-B0d oscillation frequency Δmd and new lower limits on Δms are reviewed. The world average is Δmd=0.457±0.019ℎ ps-1. Assuming τBd=(1.57±0.05) ps, it leads to a world average value of χd=0.17±0.011. From this χd value, the χ average value of 0.115±0.006 given by the EW group and taking χs=0.5 the Bs fraction has been determined to be fs=(10±2)%. The highest limit obtained on the B0s-B0s oscillation frequency is Δms>5.6ℎ ps-1 at 95% confidence level assuming fs=10%. (orig.)

  17. TEM study of impurity segregations in beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Klimenkov, M., E-mail: michael.klimenkov@kit.edu [Institute for Applied Materials – Applied Materials Physics, Karlsruhe Institute of Technology, Hermann-von-Helmholz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Chakin, V.; Moeslang, A. [Institute for Applied Materials – Applied Materials Physics, Karlsruhe Institute of Technology, Hermann-von-Helmholz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Rolli, R. [Institute for Applied Materials – Materials and Biomechanics, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2014-12-15

    Beryllium is planned to be used as a neutron multiplier in the Helium-cooled Pebble Bed European concept of a breeding blanket of demonstration power reactor DEMO. In order to evaluate the irradiation performance, individual pebbles and constrained pebble beds were neutron-irradiated at temperatures typical of fusion blankets. Beryllium pebbles 1 mm in diameter produced by the rotating electrode method were subjected to a TEM study before and after irradiation at High Flux Reactor, Petten, Netherlands at 861 K. The grain size varied in a wide range from sub-micron size up to several tens of micrometers, which indicated formation bimodal grain size distribution. Based on the application of combined electron energy loss spectroscopy and energy dispersive X-ray spectroscopy methods, we suggest that impurity precipitates play an important role in controlling the mechanical properties of beryllium. The impurity elements were present in beryllium at a sub-percent concentration form beryllide particles of a complex (Fe/Al/Mn/Cr)B composition. These particles are often ordered along dislocations lines, forming several micron-long chains. It can be suggested that fracture surfaces often extended along these chains in irradiated material.

  18. Beryllium Wipe Sampling (differing methods - differing exposure potentials)

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, Kent

    2005-03-09

    This research compared three wipe sampling techniques currently used to test for beryllium contamination on room and equipment surfaces in Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling without a wetting agent, with water-moistened wipe materials, and by methanol-moistened wipes. Analysis indicated that methanol-moistened wipe sampling removed about twice as much beryllium/oil-film surface contamination as water-moistened wipes, which removed about twice as much residue as dry wipes. Criteria at 10 CFR 850.30 and .31 were established on unspecified wipe sampling method(s). The results of this study reveal a need to identify criteria-setting method and equivalency factors. As facilities change wipe sampling methods among the three compared in this study, these results may be useful for approximate correlations. Accurate decontamination decision-making depends on the selection of appropriate wetting agents for the types of residues and surfaces. Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced removal efficiency such as methanol when surface contamination includes oil mist residue.

  19. TEM study of impurity segregations in beryllium pebbles

    Science.gov (United States)

    Klimenkov, M.; Chakin, V.; Moeslang, A.; Rolli, R.

    2014-12-01

    Beryllium is planned to be used as a neutron multiplier in the Helium-cooled Pebble Bed European concept of a breeding blanket of demonstration power reactor DEMO. In order to evaluate the irradiation performance, individual pebbles and constrained pebble beds were neutron-irradiated at temperatures typical of fusion blankets. Beryllium pebbles 1 mm in diameter produced by the rotating electrode method were subjected to a TEM study before and after irradiation at High Flux Reactor, Petten, Netherlands at 861 K. The grain size varied in a wide range from sub-micron size up to several tens of micrometers, which indicated formation bimodal grain size distribution. Based on the application of combined electron energy loss spectroscopy and energy dispersive X-ray spectroscopy methods, we suggest that impurity precipitates play an important role in controlling the mechanical properties of beryllium. The impurity elements were present in beryllium at a sub-percent concentration form beryllide particles of a complex (Fe/Al/Mn/Cr)B composition. These particles are often ordered along dislocations lines, forming several micron-long chains. It can be suggested that fracture surfaces often extended along these chains in irradiated material.

  20. Codeposition of deuterium ions with beryllium oxide at elevated temperatures

    CERN Document Server

    Markin, A V; Gorodetsky, A E; Negodaev, M A; Rozhanskii, N V; Scaffidi-Argentina, F; Werle, H; Wu, C H; Zalavutdinov, R K; Zakharov, A P

    2000-01-01

    Deuterium-loaded BeO films were produced by sputtering the beryllium target with 10 keV Ne ions in D sub 2 gas at a pressure of approximately 1 Pa. The sputtered beryllium reacts - on the substrate surface - with the residual oxygen, thus forming a beryllium oxide layer. Biasing the substrate negatively with respect to the target provides the simultaneous bombardment of the growing film surface with D ions formed by Ne-D sub 2 collisions. Substrate potential governs the maximum energy of ions striking the growing film surface while its size governs the flux density. According to X-ray photoelectron spectroscopy (XPS), electron probe microanalysis (EPMA) and reflection high energy electron diffraction (RHEED) data, the beryllium is deposited in the form of polycrystalline hcp-BeO layers with negligible (about 1 at.%) carbon and neon retention. Thermal desorption spectroscopy (TDS) data shows a strong deuterium bonding, with a desorption peak at 950 K, in the films deposited at -50 and -400 V substrate potentia...

  1. Fluorometric determination of beryllium with 2-(o-hydroxylphenyl)benzoxazole

    Energy Technology Data Exchange (ETDEWEB)

    Gladilovich, D.B.; Stolyarov, K.P.

    1985-09-01

    According to the authors, of great interest for the fluorometric determination of small quantities of beryllium is 2-(o-hydroxyphenyl)benzthiazole (HPBT). In this work, 2-(o-hydroxyphenyl)benzoaxzole (HPBO), which is an analog of HPBT and differs from it in that the sulfur atom in the heterocyclic portion of the molecule is replaced by an oxygen atom, is proposed as a reagent for the fluorometric determination of beryllium. The fluorescent reaction of HPBO with beryllium is studied in this paper, in addition to the selection of the optimum conditions for the determination and the development of a procedure for the analysis of complex objects on this basis. The reaction proceeds in aqueous ethanol medium at pH 7.2-7.5. The limit of detection is 0.6 ng/ml. Methods have been developed for the determination of 10/sup -2/% beryllium in alloys based on copper and 10/sup -3/-10/sup -4/% in standard samples of silicate rocks.

  2. Extraction of lead and beryllium from a firing site soil

    International Nuclear Information System (INIS)

    The Dual Axis Radiographic Hydrodynamic Test (DARHT) program is being implemented at LANL to conduct tests for evaluating the stability of the nation's aging nuclear stockpile. In order to reduce impact on the environment, containment of the non-fissile explosives tests is being phased in. The resulting shot debris can contain a mix of depleted uranium, lead, and beryllium. We are developing a treatment scheme to separate the radioactive and RCRA-hazardous components in order to recover the uranium, re-use some materials in future shots, and minimize waste for disposal. Our experience using a proprietary water soluble polymer to extract lead from contaminated soil to below TCLP levels has been extended to a surrogate soil from an open-air firing site that contains both lead and beryllium. Results for lead removal from this soil by dendrimers and molecular chelators will also be shown. Because of the potentially severe inhalation hazard associated with beryllium, the fate of this metal in our treatment scheme has been investigated, as well as extraction of beryllium using a variety of chemical agents

  3. Thermal cycling tests of actively cooled beryllium copper joints

    Energy Technology Data Exchange (ETDEWEB)

    Roedig, M.; Duwe, R.; Linke, J.; Schuster, A.; Wiechers, B. [Forschungszentrum Juelich GmbH (Germany)

    1998-01-01

    Screening tests (steady state heating) and thermal fatigue tests with several kinds of beryllium-copper joints have been performed in an electron beam facility. Joining techniques under investigation were brazing with silver containing and silver-free braze materials, hot isostatic pressing (HIP) and diffusion bonding (hot pressing). Best thermal fatigue performance was found for the brazed samples. (author)

  4. Hanford Site Beryllium Program: Past, Present, and Future - 12428

    International Nuclear Information System (INIS)

    The U.S. Department of Energy (DOE) has a long history of beryllium use because of the element's broad application to many nuclear operations and processes. At the Hanford Site beryllium alloy was used to fabricate parts for reactors, including fuel rods for the N-Reactor during plutonium production. Because of continued confirmed cases of chronic beryllium disease (CBD), and data suggesting CBD occurs at exposures to low-level concentrations, the DOE decided to issue a rule to further protect federal and contractor workers from hazards associated with exposure to beryllium. When the beryllium rule was issued in 1999, each of the Hanford Site contractors developed a Chronic Beryllium Disease Prevention Program (CBDPP) and initial site wide beryllium inventories. A new site-wide CBDPP, applicable to all Hanford contractors, was issued in May, 2009. In the spring of 2010 the DOE Headquarters Office of Health, Safety, and Security (HSS) conducted an independent inspection to evaluate the status of implementation of the Hanford Site Chronic Beryllium Disease Prevention Program (CBDPP). The report identified four Findings and 12 cross-cutting Opportunities for Improvement (OFIs). A corrective action plan (CAP) was developed to address the Findings and crosscutting OFIs. The DOE directed affected site contractors to identify dedicated resources to participate in development of the CAP, along with involving stakeholders. The CAP included general and contractor-specific recommendations. Following initiation of actions to implement the approved CAP, it became apparent that additional definition of product deliverables was necessary to assure that expectations were adequately addressed and CAP actions could be closed. Consequently, a supplement to the original CAP was prepared and transmitted to DOE-HQ for approval. Development of the supplemental CAP was an eight month effort. From the onset a core group of CAP development members were identified to develop a mechanism for

  5. Fundamental hydrogen interactions with beryllium : a magnetic fusion perspective.

    Energy Technology Data Exchange (ETDEWEB)

    Wampler, William R. (Sandia National Laboratories, Albuquerque, NM); Felter, Thomas E.; Whaley, Josh A.; Kolasinski, Robert D.; Bartelt, Norman Charles

    2012-03-01

    Increasingly, basic models such as density functional theory and molecular dynamics are being used to simulate different aspects of hydrogen recycling from plasma facing materials. These models provide valuable insight into hydrogen diffusion, trapping, and recombination from surfaces, but their validation relies on knowledge of the detailed behavior of hydrogen at an atomic scale. Despite being the first wall material for ITER, basic single crystal beryllium surfaces have been studied only sparsely from an experimental standpoint. In prior cases researchers used electron spectroscopy to examine surface reconstruction or adsorption kinetics during exposure to a hydrogen atmosphere. While valuable, these approaches lack the ability to directly detect the positioning of hydrogen on the surface. Ion beam techniques, such as low energy ion scattering (LEIS) and direct recoil spectroscopy (DRS), are two of the only experimental approaches capable of providing this information. In this study, we applied both LEIS and DRS to examine how hydrogen binds to the Be(0001) surface. Our measurements were performed using an angle-resolved ion energy spectrometer (ARIES) to probe the surface with low energy ions (500 eV - 3 keV He{sup +} and Ne{sup +}). We were able to obtain a 'scattering maps' of the crystal surface, providing insight on how low energy ions are focused along open surface channels. Once we completed a characterization of the clean surface, we dosed the sample with atomic hydrogen using a heated tungsten capillary. A distinct signal associated with adsorbed hydrogen emerged that was consistent with hydrogen residing between atom rows. To aid in the interpretation of the experimental results, we developed a computational model to simulate ion scattering at grazing incidence. For this purpose, we incorporated a simplified surface model into the Kalypso molecular dynamics code. This approach allowed us to understand how the incident ions interacted with the

  6. A review of hemorheology: Measuring techniques and recent advances

    Science.gov (United States)

    Sousa, Patrícia C.; Pinho, Fernando T.; Alves, Manuel A.; Oliveira, Mónica S. N.

    2016-02-01

    Significant progress has been made over the years on the topic of hemorheology, not only in terms of the development of more accurate and sophisticated techniques, but also in terms of understanding the phenomena associated with blood components, their interactions and impact upon blood properties. The rheological properties of blood are strongly dependent on the interactions and mechanical properties of red blood cells, and a variation of these properties can bring further insight into the human health state and can be an important parameter in clinical diagnosis. In this article, we provide both a reference for hemorheological research and a resource regarding the fundamental concepts in hemorheology. This review is aimed at those starting in the field of hemodynamics, where blood rheology plays a significant role, but also at those in search of the most up-to-date findings (both qualitative and quantitative) in hemorheological measurements and novel techniques used in this context, including technical advances under more extreme conditions such as in large amplitude oscillatory shear flow or under extensional flow, which impose large deformations comparable to those found in the microcirculatory system and in diseased vessels. Given the impressive rate of increase in the available knowledge on blood flow, this review is also intended to identify areas where current knowledge is still incomplete, and which have the potential for new, exciting and useful research. We also discuss the most important parameters that can lead to an alteration of blood rheology, and which as a consequence can have a significant impact on the normal physiological behavior of blood.

  7. What is compassion and how can we measure it? A review of definitions and measures.

    Science.gov (United States)

    Strauss, Clara; Lever Taylor, Billie; Gu, Jenny; Kuyken, Willem; Baer, Ruth; Jones, Fergal; Cavanagh, Kate

    2016-07-01

    The importance of compassion is widely recognized and it is receiving increasing research attention. Yet, there is lack of consensus on definition and a paucity of psychometrically robust measures of this construct. Without an agreed definition and adequate measures, we cannot study compassion, measure compassion or evaluate whether interventions designed to enhance compassion are effective. In response, this paper proposes a definition of compassion and offers a systematic review of self- and observer-rated measures. Following consolidation of existing definitions, we propose that compassion consists of five elements: recognizing suffering, understanding the universality of human suffering, feeling for the person suffering, tolerating uncomfortable feelings, and motivation to act/acting to alleviate suffering. Three databases were searched (Web of Science, PsycInfo, and Medline) and nine measures included and rated for quality. Quality ratings ranged from 2 to 7 out of 14 with low ratings due to poor internal consistency for subscales, insufficient evidence for factor structure and/or failure to examine floor/ceiling effects, test-retest reliability, and discriminant validity. We call our five-element definition, and if supported, the development of a measure of compassion based on this operational definition, and which demonstrates adequate psychometric properties. PMID:27267346

  8. Twinning and de-twinning in beryllium during strain path changes

    Energy Technology Data Exchange (ETDEWEB)

    Brown, D.W., E-mail: dbrown@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Almer, J.D. [Argonne National Laboratory, Argonne, IL 60439 (United States); Clausen, B. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Mosbrucker, P.L. [Kinectrics Inc., 800 Kipling Avenue, Unit 2, Toronto, ON, Canada M8Z 5G5 (Canada); Sisneros, T.A.; Vogel, S.C. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2013-01-01

    Rolled beryllium samples in the form of rectangular parallelepipeds were deformed at strain rates of 0.001/s and 5/s through multiple strain paths. Samples were initially deformed in-plane nominally -0.22 in compression at a rate of 5/s to populate the microstructure with twins and then reoriented and deformed a second time either in the through-thickness direction or the other in-plane direction. The microstructure (texture and internal strain) were monitored through in-situ and ex-situ diffraction measurements using neutron diffraction on the HIPPO diffractometer at LANSCE, and high energy X-ray diffraction on the 1-ID-C beamline at the APS. Twin reversal is observed when the sample is reoriented and deformed a second time in the TT direction. The twin reversal is strain rate independent in contrast to the strong strain rate dependence observed during twinning in beryllium. Deformation twinning is also observed during secondary compression in the second in-plane direction, but from the current data set we cannot determine with certainty if these twins originate from the parent orientation or the twins formed during primary in-plane compression. As a whole, this data set creates a very demanding test for the development of polycrystalline plasticity models of deformation in hexagonal metals.

  9. Interaction of implanted deuterium and helium with beryllium: radiation enhanced oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Langley, R.A.

    1979-01-01

    The interaction of implanted deuterium and helium with beryllium is of significant interest in the application of first wall coatings and other components of fusion reactors. Electropolished polycrystalline beryllium was first implanted with an Xe backscatter marker at 1.98 MeV followed by either implantation with 5 keV diatomic deuterium or helium. A 2.0 MeV He beam was used to analyze for impurity buildup; namely oxygen. The oxide layer thickness was found to increase linearly with increasing implant fluence. A 2.5 MeV H/sup +/ beam was used to depth profile the D and He by ion backscattering. In addition the retention of the implant was measured as a function of the implant fluence. The mean depth of the implant was found to agree with theoretical range calculations. Scanning electron microscopy was used to observe blister formation. No blisters were observed for implanted D but for implanted He blisters occurred at approx. 1.75 x 10/sup 17/ He cm/sup -2/. The blister diameter increased with increasing implant fluence from about 0.8 ..mu..m at 10/sup 18/ He cm/sup -2/ to 5.5 ..mu..m at 3 x 10/sup 18/ He cm/sup -2/.

  10. Laser/x-ray coupling in the first NIF beryllium implosions

    Science.gov (United States)

    Wilson, D. C.; Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Kyrala, G. A.; Perry, T. S.; Batha, S.; Callahan, D. A.; Dewald, E. L.; Jones, O.; Hinkel, D. E.; Hurricane, O. A.; Izumi, N.; Macphee, A. G.; Milovich, J. L.; Ralph, J. E.; Rygg, J. R.; Schneider, M. B.; Strozzi, D. J.; Thomas, C. A.; Tommasini, R.

    2015-11-01

    The x-ray flux driving a capsule is currently overestimated in standard Hydra high-flux model (Rosen et al., HEDP 7,180 (2011)) calculations of gas-filled hohlraums. Jones et al. (Phys. Plasmas,19,056315 (2012)) introduced time dependent multipliers to reduce the laser drive and achieve an appropriate radiation drive on NIF capsules. Using shock velocities from VISAR capsule experiments, symmetry capsule implosion times with truncated laser pulses, and time dependent DANTE X-ray flux measurements from 1D and 2D convergent ablator implosions, we derived a set of time dependent flux multipliers for the first NIF cryogenically layered beryllium capsule implosion. The similarity between these multipliers for both plastic and beryllium capsules suggests that they are primarily correcting for improper modeling of the hohlraum physics, with possibly some residual contribution from capsule modeling deficiencies. Using Lasnex we have adjusted hohlraum physics and resolution in an attempt to model these implosions without drive multipliers. This work was funded by the US Department of Energy.

  11. Beryllium coating produced by evaporation-condensation method and some their properties

    Energy Technology Data Exchange (ETDEWEB)

    Pepekin, G.I.; Anisimov, A.B.; Chernikov, A.S.; Mozherinn, S.I.; Pirogov, A.A. [SRI SIA Lutch., Podolsk (Russian Federation)

    1998-01-01

    The method of vacuum evaporation-condensation for deposition of beryllium coatings on metal substrates, considered in the paper, side by side with a plasma-spray method is attractive fon ITER application. In particular this technique may be useful for repair the surface of eroded tiles which is operated in a strong magnetic field. The possibility of deposition of beryllium coatings with the rate of layer growth 0.1-0.2 mm/h is shown. The compatibility of beryllium coating with copper or stainless steel substrate is provided due to intermediate barrier. The results of examination of microstructure, microhardness, porosity, thermal and physical properties and stability under thermal cycling of beryllium materials are presented. The value of thermal expansion coefficient and thermal conductivity of condensed beryllium are approximately the same as for industrial grade material produced by powder mettalurgy technique. However, the condensed beryllium has higher purity (up to 99.9-99.99 % wt.). (author)

  12. 5. IEA International workshop on beryllium technology for fusion. Book of abstracts

    International Nuclear Information System (INIS)

    The collection includes the abstracts of reports presented to the 5-th IEA international workshop on beryllium technology for fusion. The themes of reports are as follows: status of beryllium technology for fusion in Russia; manufacturing and testing of Be armoured first wall mock-up for ITER; development of the process of diffusion welding of metals stainless steel-copper-beryllium into a single composite; some features of beryllium-laser beam interaction; the effect of irradiation dose on tritium and helium release from neutron irradiated beryllium; thermal properties of neutron irradiated Be12Ti. The results of investigating the mechanical properties variation and swelling of beryllium under high temperature neutron irradiation are presented

  13. JET-ISX-B beryllium limiter experiment safety analysis report and operational safety requirements

    International Nuclear Information System (INIS)

    An experiment to evaluate the suitability of beryllium as a limiter material has been completed on the ISX-B tokamak. The experiment consisted of two phases: (1) the initial operation and characterization in the ISX experiment, and a period of continued operation to the specified surface fluence (1022 atoms/cm2) of hydrogen ions; and (2) the disassembly, decontamination, or disposal of the ISX facility. During these two phases of the project, the possibility existed for beryllium and/or beryllium oxide powder to be produced inside the vacuum vessel. Beryllium dust is a highly toxic material, and extensive precautions are required to prevent the release of the beryllium into the experimental work area and to prevent the contamination of personnel working on the device. Details of the health hazards associated with beryllium and the appropriate precautions are presented. Also described in appendixes to this report are the various operational safety requirements for the project

  14. Proceedings of the 8th specialist meeting on recycling of irradiated Beryllium

    International Nuclear Information System (INIS)

    This report summarizes the documents presented in the 8th Specialist Meeting on Recycling of Irradiated Beryllium, which was held on October 28, 2013, in Bariloche, Río Negro, Argentina, hosted by INVAP and CNEA (Comision Nacional de Energia Atomica). The objective of the meeting is to exchange the information of current status and future plan for beryllium study in the Research/Testing reactors, and to make a discussion of “How to cooperate”. There were 20 participants from USA, Japan, Korea, Austria and Argentina. In this meeting, information exchange of current status and future plan for beryllium study was carried out for the Research/Testing reactor fields, and evaluation results of beryllium materials were discussed based on new irradiated beryllium data such as swelling, deformation, gas release and so on. The subject of the used beryllium recycling was also discussed for the enforcement of demonstration recycling tests. (author)

  15. Be{sub 2}C formation in beryllium-carbon binary system by vacuum heating

    Energy Technology Data Exchange (ETDEWEB)

    Ashida, Kan; Watanabe, Kuniaki [Toyama Univ. (Japan). Hydrogen Isotope Research Center

    1998-01-01

    The surface chemical states of beryllium and carbon binary systems at elevated temperature were investigated by means of x-ray photoelectron spectroscopy (XPS) and secondary ion mass spectroscopy (SIMS). The XPS measurements revealed that the mixed subsurface layers containing Be and C readily yield Be{sub 2}C layers by vacuum heating and ion bombardment. The SIMS measurements showed that hydrogen isotope atoms are trapped by three distinct sites; namely Be, C, and O-sites on the sample surface. The SIMS measurements also showed that carbon atoms lose its ability to bind with hydrogen isotope atoms on forming Be{sub 2}C. It would be a key to control hydrogen inventory when Be and C are used together as PFM. (author)

  16. Effects of beryllium-compounds on the hen. 2. Comm

    International Nuclear Information System (INIS)

    After oral application of 7Be2+ this cation is relative slowly absorbed from the intestine. The highest proportion of 7Be appeared in the feces. The absorbed 7Be has been found in the feathers, the bones and in the muscles as well as in the mucosa of the stomach and the intestine. Relative low is the accumulation in the liver and the kidneys as well as in the brain and the spinal cord. After i.v. application a high proportion of 7Be has been observed in the eggs. The rest of the applied radio-beryllium has been accumulated 7Be in the metabolically active tissues is removed very slowly. In contrast to this observation radio-beryllium disappeared relatively rapidly from the blood. (orig.)

  17. Quantum-chemical approach to cohesive properties of metallic beryllium

    International Nuclear Information System (INIS)

    Calculations based upon the incremental approach, i.e. an expansion of the correlation energy in terms of one-body, two-body, and higher-order contributions from localized orbital groups, have been performed for metallic beryllium. We apply an embedding scheme which has been successfully applied recently to ground-state properties of magnesium and group 12 elements. This scheme forces localization in metallic-like model systems and allows for a gradual delocalization within the incremental approach. Quantum-chemical methods of the coupled-cluster and multi-reference configuration interaction type are used for evaluating individual increments. Results are given for the cohesive energy and lattice constants of beryllium, and it is shown that further development of the approach is needed for this difficult case

  18. Studies on extraction of beryllium from thiocyanate solutions by quaternary ammonium halides.

    Science.gov (United States)

    El-Yamani, I S; El-Messieh, E N

    A 0.4M tricaprylmethylammonium chloride solution in n-hexane was used for the quantitative extraction of beryllium from hydrochloric acid (pH 3) and 5M potassium thiocyanate. Beryllium was stripped from the organic phase with 1M sodium hydroxide, then determined volumetrically with bismuthyl perchlorate and bromocresol green indicator. Beryllium was extracted in presence of a large number of elements which are usually associated with it in beryl and in fission products of nuclear fuel.

  19. Dose Rates from Plutonium Metal and Beryllium Metal in a 9975 Shipping Container

    International Nuclear Information System (INIS)

    A parametric study was performed of the radiation dose rates that might be produced if plutonium metal and beryllium metal were shipped in the 9975 shipping package. These materials consist of heterogeneous combinations plutonium metal and beryllium. The plutonium metal content varies up to 4.4 kilograms while the beryllium metal varies up to 4 kilograms. This paper presents the results of that study

  20. Impact of HFIR LEU Conversion on Beryllium Reflector Degradation Factors

    Energy Technology Data Exchange (ETDEWEB)

    Ilas, Dan [ORNL

    2013-10-01

    An assessment of the impact of low enriched uranium (LEU) conversion on the factors that may cause the degradation of the beryllium reflector is performed for the High Flux Isotope Reactor (HFIR). The computational methods, models, and tools, comparisons with previous work, along with the results obtained are documented and discussed in this report. The report documents the results for the gas and neutronic poison production, and the heating in the beryllium reflector for both the highly enriched uranium (HEU) and LEU HFIR configurations, and discusses the impact that the conversion to LEU may have on these quantities. A time-averaging procedure was developed to calculate the isotopic (gas and poisons) production in reflector. The sensitivity of this approach to different approximations is gauged and documented. The results show that the gas is produced in the beryllium reflector at a total rate of 0.304 g/cycle for the HEU configuration; this rate increases by ~12% for the LEU case. The total tritium production rate in reflector is 0.098 g/cycle for the HEU core and approximately 11% higher for the LEU core. A significant increase (up to ~25%) in the neutronic poisons production in the reflector during the operation cycles is observed for the LEU core, compared to the HEU case, for regions close to the core s horizontal midplane. The poisoning level of the reflector may increase by more than two orders of magnitude during long periods of downtime. The heating rate in the reflector is estimated to be approximately 20% lower for the LEU core than for the HEU core. The decrease is due to a significantly lower contribution of the heating produced by the gamma radiation for the LEU core. Both the isotopic (gas and neutronic poisons) production and the heating rates are spatially non-uniform throughout the beryllium reflector volume. The maximum values typically occur in the removable reflector and close to the midplane.

  1. Presence of Beryllium (Be) in urban soils: human health risk

    Energy Technology Data Exchange (ETDEWEB)

    Pena, A.; Gonzalez, M. J.; Lobo, M. C.

    2009-07-01

    Berylium (Be) is, together with As, Cd, Hg, Pb and Ti, one of the trace elements more toxic for human being (Vaessen) and Szteke, 2000; Yaman and Avci, 2006), but in spite of the exponential increment of its applications during the last decades, surprisingly there isn't hardly information about its presence and environmental distribution. The aim of this work is to evaluate the presence of Beryllium in urban soils in Alcala de Henares, (Madrid Spain).

  2. Analysis of features of the deformation of auxetic beryllium

    OpenAIRE

    Гунько, Михаил Николаевич; Олейнич-Лысюк, Алла Васильевна; Раранский, Николай Дмитриевич; Тащук, Александр Юрьевич

    2015-01-01

    In the framework of the linear elasticity theory using the experimentally obtained elastic stiffness modules, temperature dependences of the elastic compliance modules and tensor components of Poisson's ratios    of beryllium in a wide range of temperatures and directions in the crystal lattice were calculated, and it was shown that with increasing temperature, the value and signs of Poisson's ratios  change differently in various temperature intervals. In the interval 0-300K,  become negativ...

  3. Detail analysis of fusion neutronics benchmark experiment on beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Konno, Chikara, E-mail: konno.chikara@jaea.go.j [Fusion Research and Development Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Ochiai, Kentaro; Takakura, Kosuke; Ohnishi, Seiki; Kondo, Keitaro [Fusion Research and Development Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Wada, Masayuki [Japan Computer System, Mito-shi, Ibaraki-ken 310-0805 (Japan); Sato, Satoshi [Fusion Research and Development Directorate, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan)

    2010-12-15

    Our previous analysis of the integral experiments (in situ and TOF experiments) on beryllium with DT neutrons at JAEA/FNS pointed out two problems by using MCNP4C and the latest nuclear data libraries; one was a strange larger neutron peak around 12 MeV appearing in the TOF experiment analysis with JEFF-3.1 and the other was an overestimation on law energy neutrons in the in situ experiment analyses with all the nuclear data libraries. We investigated reasons for these problems in detail. It was found out that the official ACE file MCJEFF3.1 of JEFF-3.1 had an inconsistency with the original JEFF-3.1, which caused the strange larger neutron peak around 12 MeV in the TOF experiment analysis. We also found out that the calculated thermal neutron peak was probably too large in the in situ experiment. On trial we examined influence of the thermal neutron scattering law data of beryllium metal in ENDF/B-VI. The result pointed out that the coherent elastic scattering cross-section data in the thermal neutron scattering law data of beryllium metal were probably too large.

  4. Electron microscope study of thin beryllium lamellae (1963)

    International Nuclear Information System (INIS)

    Thin SR beryllium lamellae are examined by electron microscopy after various treatments, together with other samples made up of Be - Fe at 1 per cent and 0.2 per cent iron. The SR beryllium is examined after annealing at 750 deg C and 900 deg C, strongly cold-worked and quenched at 900 deg C. At 950 deg C the metal is perfectly annealed; at 750 deg C the polygonisation is almost complete, the dislocations are arranged either is dislocation walls in the prismatic planes, or in hexagonal lattices with non-dissociated nodes suggesting a high stacking defect energy. The cold-worked structure has a high dislocation density and already existing crystal walls. In the quenched state, the few dislocations are very straight and are aligned in the crystallographic directions. Iron-precipitation is studied in two alloys during tempering at 660 deg after quenching in salt water. The precipitate appears at the grain boundaries and then spreads through the matrix leaving a depleted zone in the neighbourhood of the joints. These precipitates, in the form of platelets parallel to the base planes of the beryllium lattice have been identified as the inter metallic phase Be11 Fe oriented in relation to the matrix (0 0 0 1)//(0 0 0 1) (1 0 1-bar 0)//(1 1 2-bar 0). (authors)

  5. A diethylhydroxylaminate based mixed lithium/beryllium aggregate

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Raphael J.F. [Paris-Lodron Universitaet Salzburg (Austria). Fachbereich fuer Materialwissenschaften und Physik; Jana, Surajit [Asansol Girls College, West-Bengal (India). Dept. of Chemistry; Froehlich, Roland [Muenster Univ. (Germany). Organisch-Chemisches Inst.; Mitzel, Norbert W. [Bielefeld Univ. (Germany). Anorganische Chemie und Strukturchemie

    2015-07-01

    A mixed lithium/beryllium diethylhydroxylaminate compound containing {sup n}butyl beryllium units of total molecular composition {sup n}Be(ONEt{sub 2}){sub 2} [(LiONEt{sub 2}){sup 2} {sup n}BuBeONEt{sub 2}]{sub 2} (1) was isolated from a reaction mixture of {sup n}butyl lithium, N,N-diethylhydroxylamine and BeCl{sub 2} in diethylether/thf. The crystal structure of 1 has been determined by X-ray diffraction. The aggregate is composed of two ladder-type subunits connected in a beryllium-centered distorted tetrahedron of four oxygen atoms. Only the lithium atoms are engaged in coordination with the nitrogen donor atoms. The DFT calculations support the positional occupation determined for Li and Be in the crystal structure. The DFT and the solid-state structure are in excellent agreement, indicating only weak intermolecular interactions in the solid state. Structural details of metal atom coordination are discussed.

  6. Measures of Consumer Satisfaction in Social Welfare and Behavioral Health: A Systematic Review

    Science.gov (United States)

    Fraser, Mark W.; Wu, Shiyou

    2016-01-01

    This article reviews the origins, conceptual bases, psychometric properties, and limitations of consumer satisfaction measures in social welfare and behavioral health. Based on a systematic review of research reports published between 2003 and 2013, we identify 58 consumer satisfaction measures. On average, these measures have acceptable…

  7. Beryllium Science: US-UK agreement on the use of Atomic Energy for mutual defense

    Energy Technology Data Exchange (ETDEWEB)

    Hanafee, J.E. (ed.)

    1988-02-19

    Twenty-seven papers are presented on beryllium supply, production, fabrication, safe handling, analysis, powder technology, and coatings. Separate abstracts have been prepared for the individual papers. (DLC)

  8. Problems and future plan on material development of beryllium in materials testing reactors

    International Nuclear Information System (INIS)

    Beryllium has been utilized as a moderator and/or reflector in a number of material testing reactors. The attractive nuclear properties of beryllium are its low atomic number, low atomic weight, low parasitic capture cross section for thermal neutrons, readiness to part with one of its own neutrons, and good neutron elastic scattering characteristics. However, it is difficult to reprocess irradiated beryllium because of high induced radioactivity. Disposal has also been difficult because of toxicity issues and special nuclear material controls. In this paper, problems and future plans of beryllium technology are introduced for nuclear reactors. (author)

  9. The impact of beryllium chloride and oxide on sexual function and offspring development in female rats

    International Nuclear Information System (INIS)

    The comparative study of the action of soluble chloride and difficultly soluble beryllium oxide on sexual cycle in female rats and their conception capability, revealing of embryotoxic and teratogenic effect of these compounds and determination of significance of terms of their impact on pregnant female as well as beryllium capability to penetrate through the placenta and accumulate in the offspring organism have been performed. A great potential danger of impact on animal reproductive function of soluble (chloride) beryllium compounds as compared with low soluble ones (oxide). In the genesis of embryotoxic teratonic effect probably along with beryllium impact on progeny through the maternal organism there occurs its direct impact on the offspring

  10. Vacuum Brazing of Beryllium Copper Components for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Tyhurst, C.C.; Cunningham, M.A.

    2002-06-04

    A process for vacuum brazing beryllium copper anode assemblies was required for the Plasma Electrode Pockels Cell System, or PEPC, a component for the National Ignition Facility (NIF). Initial problems with the joint design and wettability of the beryllium copper drove some minor design changes. Brazing was facilitated by plating the joint surface of the beryllium copper rod with silver 0.0006 inch thick. Individual air sampling during processing and swipe tests of the furnace interior after brazing revealed no traceable levels of beryllium.

  11. Beryllium Science: US-UK agreement on the use of Atomic Energy for mutual defense

    International Nuclear Information System (INIS)

    Twenty-seven papers are presented on beryllium supply, production, fabrication, safe handling, analysis, powder technology, and coatings. Separate abstracts have been prepared for the individual papers

  12. A combined radial collimator and cooled beryllium filter for neutron scattering

    Science.gov (United States)

    Groitl, Felix; Rantsiou, Emmanouela; Bartkowiak, Marek; Filges, Uwe; Graf, Dieter; Niedermayer, Christof; Rüegg, Christian; Rønnow, Henrik M.

    2016-05-01

    A flexible, combined, radial collimator and beryllium (Be) filter have been designed and manufactured at the Paul Scherrer Institut (PSI), Switzerland. The Be is integrated in the radial collimator by placing thin Be slices between the collimator lamellas. The filter/collimator is mounted within a vacuum vessel and dry cooled. The flexible design allows for different degrees of collimation and for different Be lengths. Results of measurements carried out at the BOA beamline at PSI are presented. These experiments include rotation scans determining the focal full width half maximum (FWHM), transmission measurements, test of different collimator lamellas and performance tests of the cooling of the filter. This new combined device will be a crucial part of the CAMEA spectrometer at SINQ, PSI.

  13. Surface energy balance measurements in the Mexico City: a review

    Energy Technology Data Exchange (ETDEWEB)

    Tejeda Martinez, A. [Universidad Veracruzana, Xalapa, Veracruz (Mexico); Jauregui Ostos, E. [Centro de Ciencias de la Atmosfera, Universidad Nacional Autonoma de Mexico, UNAM, Mexico, D.F. (Mexico)

    2005-01-01

    During the last decade of the 20th Century, diverse campaigns for measuring the atmospheric energy balance were performed in downtown Mexico City (School of Mines and Preparatory School No. 7), in the southern suburbs (University Reserve) and in the surrounding rural areas (Plan Texcoco), in addition to a campaign carried out in 1985 in the Tacubaya district, a suburban western peripheral site. The objective was to obtain data for a better understanding of the climatic alterations due to urbanization, particularly to describe the role that the modification of the natural ground cover has played as a result of paving and the construction of urban canyons. In this paper, a review of these campaigns is presented. Energy partitioning in some areas (Tacubaya and Preparatory School No.7) is similar to that observed in urban centers of middle latitudes, whereas the major contrast was observed between Texcoco, with maximum energy consumption through evaporation, and School of Mines, where the latent heat is as low as in a desert. From the values of the correlations among the different components of energy balance, it may be possible to attempt the modeling of the diverse components of energy balance by means of regression equations starting from the net radiation. Those same coefficients distinguish the type of environment: urban, suburban or rural. [Spanish] Las primeras mediciones de balance energetico en la Ciudad de Mexico se realizaron en 1985 en un suburbio al poniente de la ciudad (el observatorio de Tacubaya). Ya en la decada de los anos noventa del siglo XX, dichas observaciones se multiplicaron tanto en el centro historico (antigua Escuela de Minas y en el edificio de la Preparatoria No. 7), como en otros sitios al sur (en terrenos de Ciudad Universitaria) y en la periferia rural (Plan Texcoco). El proposito de estas mediciones ha sido tener un mejor entendimiento de las alteraciones climaticas debidas a la urbanizacion. En este trabajo se presenta una revision

  14. Beryllium metal I. experimental results on acute oral toxicity, local skin and eye effects, and genotoxicity.

    Science.gov (United States)

    Strupp, Christian

    2011-01-01

    The toxicity of soluble metal compounds is often different from that of the parent metal. Since no reliable data on acute toxicity, local effects, and mutagenicity of beryllium metal have ever been generated, beryllium metal powder was tested according to the respective Organisation for Economical Co-Operation and Development (OECD) guidelines. Acute oral toxicity of beryllium metal was investigated in rats and local effects on skin and eye in rabbits. Skin-sensitizing properties were investigated in guinea pigs (maximization method). Basic knowledge about systemic bioavailability is important for the design of genotoxicity tests on poorly soluble substances. Therefore, it was necessary to experimentally compare the capacities of beryllium chloride and beryllium metal to form ions under simulated human lung conditions. Solubility of beryllium metal in artificial lung fluid was low, while solubility in artificial lysosomal fluid was moderate. Beryllium chloride dissolution kinetics were largely different, and thus, metal extracts were used in the in vitro genotoxicity tests. Genotoxicity was investigated in vitro in a bacterial reverse mutagenicity assay, a mammalian cell gene mutation assay, a mammalian cell chromosome aberration assay, and an unscheduled DNA synthesis (UDS) assay. In addition, cell transformation was tested in a Syrian hamster embryo cell assay, and potential inhibition of DNA repair was tested by modification of the UDS assay. Beryllium metal was found not to be mutagenic or clastogenic based on the experimental in vitro results. Furthermore, treatment with beryllium metal extracts did not induce DNA repair synthesis, indicative of no DNA-damaging potential of beryllium metal. A cell-transforming potential and a tendency to inhibit DNA repair when the cell is severely damaged by an external stimulus were observed. Beryllium metal was also found not to be a skin or eye irritant, not to be a skin sensitizer, and not to have relevant acute oral

  15. Thermal flux measurements in hypersonic flows: A review

    Science.gov (United States)

    Wendt, J. F.; Balageas, D.; Neumann, R. D.

    1993-04-01

    This contribution reviews the papers presented in the Session on 'Heat Flux' and 'Thermography' at a NATO Advanced Research Workshop entitled 'New Trends in Instrumentation for Hypersonic Research', 27 April-1 May, 1992, Le Fauga, France. The present status and problem areas associated with specific methods are discussed and recommendations for future research and development are presented.

  16. Measuring Competitive Effects from School Voucher Programs: A Systematic Review

    Science.gov (United States)

    Egalite, Anna J.

    2013-01-01

    Studies of the competition effects from voucher or tuition tax credit scholarship programs on public school student academic outcomes have taken place in seven locations throughout the United States, with the majority of studies taking place in Florida, followed by Wisconsin. This article reviews 21 total studies of the impacts on student academic…

  17. A REVIEW OF ENVIRONMENTAL APPLICATIONS OF BIOLUMINESCENCE MEASUREMENTS

    Science.gov (United States)

    This review of the recent literature on environmental applications of bioluminescence systems will focus on in vivo and in vitro bioluminescence methods that have been utilized to elucidate properties of chemicals, toxic and mutagenic effects, and to estimate biomass. The unifyin...

  18. Wellness: A Review of Theory and Measurement for Counselors

    Science.gov (United States)

    Roscoe, Lauren J.

    2009-01-01

    Wellness is considered the paradigm of counseling and development (J. E. Myers, 1991, 1992). However, researchers have failed to agree on a definition or on the dimensional structure of wellness. Furthermore, existing quantitative wellness instruments are inadequate for capturing the complexity of wellness. The author reviews wellness theory and…

  19. Analysis of the KANT experiment on beryllium using TRIPOLI-4 Monte Carlo code

    International Nuclear Information System (INIS)

    Beryllium is an important material in fusion technology for multiplying neutrons in blankets. However, beryllium nuclear data are differently presented in modern nuclear data evaluations. Recent investigations with the TRIPOLI-4 Monte Carlo simulation of the tritium breeding ratio (TBR) demonstrated that beryllium reaction data are the main source of the calculation uncertainties between ENDF/B-VII.0 and JEFF-3.1. To clarify the calculation uncertainties from data libraries on beryllium, in this study TRIPOLI-4 calculations of the Karlsruhe Neutron Transmission (KANT) experiment have been performed by using ENDF/B-VII.0 and new JEFF-3.1.1 data libraries. The KANT Experiment on beryllium has been used to validate neutron transport codes and nuclear data libraries. An elaborated KANT experiment benchmark has been compiled and published in the NEA/SINBAD database and it has been used as reference in the present work. The neutron multiplication in bulk beryllium assemblies was considered with a central D-T neutron source. Neutron leakage spectra through the 5, 10, and 17 cm thick spherical beryllium shells were calculated and five-group partial leakage multiplications were reported and discussed. In general, improved C/E ratios on neutron leakage multiplications have been obtained. Both ENDF/B-VII.0 and JEFF-3.1.1 beryllium data libraries of TRIPOLI-4 are acceptable now for fusion neutronics calculations.

  20. Proceedings of the third IEA international workshop on beryllium technology for fusion

    International Nuclear Information System (INIS)

    This report is the Proceedings of the Third International Energy Agency International Workshop on Beryllium Technology for Fusion. The workshop was held on October 22-24, 1997, at the Sangyou Kaikan in Mito City with 68 participants who attended from the Europe, the Russian Federation, the Kazakstan, the United States and Japan. The topics for papers were arranged into 9 sessions; beryllium applications for ITER, production and characterization, chemical compatibility and corrosion, forming and joining, plasma/tritium interactions, beryllium coating, first wall applications, neutron irradiation effects, health and safety. To utilize beryllium in the pebble type blanket, a series of discussions were intensified in multiple view points such as the swelling, He/T release from beryllium pebble irradiated up to high He content, effective thermal conductivity, tritium permeation and coating, and fabrication cost, and so on. As the plasma facing material, life time of beryllium and coated beryllium, dust and particle production, joining, waste treatment, mechanical properties and deformation by swelling were discussed as important issues. Especially, it was recognized throughout the discussions that the comparative study by the different researchers should be carried out to establish the reliability of the data reported in the workshop and in others. To enhance the comparative study, the world wide collaboration for the relative evaluation of the beryllium was proposed by the International Organization Committee and the proposal was approved by all of the participants. The 45 of the presented papers are indexed individually. (J.P.N.)

  1. Proceedings of the third IEA international workshop on beryllium technology for fusion

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Hiroshi; Okamoto, Makoto [eds.

    1998-01-01

    This report is the Proceedings of the Third International Energy Agency International Workshop on Beryllium Technology for Fusion. The workshop was held on October 22-24, 1997, at the Sangyou Kaikan in Mito City with 68 participants who attended from the Europe, the Russian Federation, the Kazakstan, the United States and Japan. The topics for papers were arranged into 9 sessions; beryllium applications for ITER, production and characterization, chemical compatibility and corrosion, forming and joining, plasma/tritium interactions, beryllium coating, first wall applications, neutron irradiation effects, health and safety. To utilize beryllium in the pebble type blanket, a series of discussions were intensified in multiple view points such as the swelling, He/T release from beryllium pebble irradiated up to high He content, effective thermal conductivity, tritium permeation and coating, and fabrication cost, and so on. As the plasma facing material, life time of beryllium and coated beryllium, dust and particle production, joining, waste treatment, mechanical properties and deformation by swelling were discussed as important issues. Especially, it was recognized throughout the discussions that the comparative study by the different researchers should be carried out to establish the reliability of the data reported in the workshop and in others. To enhance the comparative study, the world wide collaboration for the relative evaluation of the beryllium was proposed by the International Organization Committee and the proposal was approved by all of the participants. The 45 of the presented papers are indexed individually. (J.P.N.)

  2. Tritium release from highly neutron irradiated constrained and unconstrained beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Chakin, V., E-mail: vladimir.chakin@kit.edu; Rolli, R.; Vladimirov, P.; Moeslang, A.

    2015-06-15

    Highlights: • For the irradiated constrained beryllium pebbles, the tritium release occurs easier than for the unconstrained ones. • Tritium retention in the irradiated constrained and unconstrained beryllium pebbles decreases with increasing irradiation temperature. • Formation of sub-grains in the constrained beryllium pebbles facilitate the open porosity network formation. - Abstract: Beryllium is the reference neutron multiplier material in the Helium Cooled Pebble Bed (HCPB) breeding blanket of fusion power plants. Significant tritium inventory accumulated in beryllium as a result of neutron-induced transmutations could become a safety issue for the operation of such blankets as well as for the nuclear waste utilization. To provide a related materials database, a neutron irradiation campaign of beryllium pebbles with diameters of 0.5 and 1 mm at 686–1006 K, the HIDOBE-01 experiment, has been performed in the HFR in Petten, the Netherlands, producing up to 3020 appm helium and 298 appm tritium. Thermal desorption tests of irradiated unconstrained and constrained beryllium pebbles were performed in a purge gas flow using a quadrupole mass-spectrometer (QMS) and an ionization chamber. Compared to unconstrained pebbles, constrained beryllium pebbles have an enhanced tritium release at all temperatures investigated. Small elongated sub-grains formed under irradiation in the constrained pebbles promote formation of numerous channels for facilitated tritium release.

  3. 10 CFR 71.23 - General license: Plutonium-beryllium special form material.

    Science.gov (United States)

    2010-01-01

    ... requirements of 49 CFR 173.417(a). (b) The general license applies only to a licensee who has a quality... 10 Energy 2 2010-01-01 2010-01-01 false General license: Plutonium-beryllium special form material... RADIOACTIVE MATERIAL General Licenses § 71.23 General license: Plutonium-beryllium special form material....

  4. A Study Of Cosmic Ray Beryllium With The Isotope Magnet Experiment (isomax)

    CERN Document Server

    Geier, S

    2000-01-01

    Secondary nuclei in the cosmic radiation, which are produced in the process of propagation and nuclear fragmentation of primary particles through the interstellar medium, can be used to gain information on the propagation mechanism, and the details of the cosmic ray diffusion and the gas distribution in the galaxy. The Goddard ISOMAX experiment is a state-of-the-art mass spectrometer constructed for the purpose of measuring the abundance ratios of the isotopes of Beryllium, especially [10]Be which has a half life of 1.51 Myrs, at energies around 1 GeV per nucleon. This will enable the balloon borne instrument, which was launched for the first time in summer 1998, to put constraints on the typical travel times of cosmic rays and the density of the propagated medium—hence on the question how much time cosmic rays spend traveling outside the galactic disk. Construction and calibration of the instrument are presented and the first results are reported.

  5. Advanced Measuring (Instrumentation Methods for Nuclear Installations: A Review

    Directory of Open Access Journals (Sweden)

    Wang Qiu-kuan

    2012-01-01

    Full Text Available The nuclear technology has been widely used in the world. The research of measurement in nuclear installations involves many aspects, such as nuclear reactors, nuclear fuel cycle, safety and security, nuclear accident, after action, analysis, and environmental applications. In last decades, many advanced measuring devices and techniques have been widely applied in nuclear installations. This paper mainly introduces the development of the measuring (instrumentation methods for nuclear installations and the applications of these instruments and methods.

  6. Measuring marketing performance: a review and a framework

    OpenAIRE

    Gao, Yuhui

    2010-01-01

    Critics of marketing commonly allude to problems with its accountability and credibility. In order to address these issues, marketing professionals have been called on to demonstrate the contribution of marketing to firm performance. A better understanding of current research in marketing performance can better enable marketing managers to justify its expense. Given the foregoing, it was determined to (1) review the current status of marketing performance studies, and (2) develop a comprehens...

  7. Deformation behaviour of fine grained high purity beryllium - influence of fabrication parameters, temperature and copper additions

    International Nuclear Information System (INIS)

    The deformation behaviour of high-purity beryllium was tested on hot isostatically pressed samples of different initial grain size and compared with material manufactured commercially from pure beryllium and with beryllium-copper alloys containing 0.44, 1.1 and 2.1 at.% copper. Initial grain size of these high purity material was 0C. Grain structure of the samples was subsequently analysed by light, rastor and transmission electron microscopy. The influence of copper additions on deformation of high-purity beryllium was analysed. A further aim of this study was to investigate, by suitable methods, the mode of action of relevant impurities and to throw light on their influence on grain formation. This should enable reliable information to be provided for the manufacture of high-purity beryllium which, in turn, will lead to an improvement in ductility. (orig./IHOE)

  8. Patient-reported outcome measures for asthma : a systematic review

    NARCIS (Netherlands)

    Worth, Allison; Hammersley, Victoria; Knibb, Rebecca; Flokstra-de-Blok, Bertine; DunnGalvin, Audrey; Walker, Samantha; Dubois, Anthony E J; Sheikh, Aziz

    2014-01-01

    BACKGROUND: Patient-reported outcome measures (PROMs) are measures of the outcome of treatment(s) reported directly by the patient or carer. There is increasing international policy interest in using these to assess the impact of clinical care. AIMS: To identify suitably validated PROMs for asthma a

  9. Use of notched beams to establish fracture criteria for beryllium

    International Nuclear Information System (INIS)

    The fracture of an improved form of pure beryllium was studied under triaxial tensile stresses. This state of stress was produced by testing notched beams, which were thick enough to be in a state of plane strain at the center. A plane strain, elastic-incremental plasticity finite element program was then used to determine the stress and strain distributions at fracture. A four-point bend fixture was used to load the specimens. It was carefully designed and manufactured to eliminate virtually all of the shear stresses at the reduced section of the notched beams. The unixial properties were obtained

  10. Beryllium ignition target design for indirect drive NIF experiments

    Science.gov (United States)

    Simakov, A. N.; Wilson, D. C.; Yi, S. A.; Kline, J. L.; Salmonson, J. D.; Clark, D. S.; Milovich, J. L.; Marinak, M. M.

    2016-03-01

    Beryllium (Be) ablator offers multiple advantages over carbon based ablators for indirectly driven NIF ICF ignition targets. These are higher mass ablation rate, ablation pressure and ablation velocity, lower capsule albedo, and higher thermal conductivity at cryogenic temperatures. Such advantages can be used to improve the target robustness and performance. While previous NIF Be target designs exist, they were obtained a long time ago and do not incorporate the latest improved physical understanding and models based upon NIF experiments. Herein, we propose a new NIF Be ignition target design at 1.45 MJ, 430 TW that takes all this knowledge into account.

  11. Dosage of boron traces in graphite, uranium and beryllium oxide

    International Nuclear Information System (INIS)

    The problem of the dosage of the boron in the materials serving to the construction of nuclear reactors arises of the following way: to determine to about 0,1 ppm close to the quantities of boron of the order of tenth ppm. We have chosen the colorimetric analysis with curcumin as method of dosage. To reach the indicated contents, it is necessary to do a previous separation of the boron and the materials of basis, either by extraction of tetraphenylarsonium fluoborate in the case of the boron dosage in uranium and the beryllium oxide, either by the use of a cations exchanger resin of in the case of graphite. (M.B.)

  12. Technique of beryllium determination using an (α,n) reaction

    International Nuclear Information System (INIS)

    The possibility of detecting small amounts of 9Be using the (α, n) reaction has been investigated. It is shown that at a 210Po α-particle source intensity of 3x108 s-1 for limit of the detectable amount of beryllium is equal to 0.1 μg in the case of recording neutron-gamma (>= 3.6 MeV) coincidences. Other light elements (B, F, Al, Mg, Si etc.) do not produce a noticeable background under such conditions

  13. Double K-shell photoionization of atomic beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Yip, F. L. [Departamento de Quimica, Modulo 13, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); Martin, F. [Departamento de Quimica, Modulo 13, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); Instituto Madrilen(tilde sign)o de Estudios Avanzados en Nanociencia, Cantoblanco, E-28049 Madrid (Spain); McCurdy, C. W. [Department of Chemistry, University of California, Davis, California 95616 (United States); Lawrence Berkeley National Laboratory, Chemical Sciences, and Ultrafast X-ray Science Laboratory, Berkeley, California 94720 (United States); Rescigno, T. N. [Lawrence Berkeley National Laboratory, Chemical Sciences, and Ultrafast X-ray Science Laboratory, Berkeley, California 94720 (United States)

    2011-11-15

    Double photoionization of the core 1s electrons in atomic beryllium is theoretically studied using a hybrid approach that combines orbital and grid-based representations of the Hamiltonian. The {sup 1} S ground state and {sup 1} P final state contain a double occupancy of the 2s valence shell in all configurations used to represent the correlated wave function. Triply differential cross sections are evaluated, with particular attention focused on a comparison of the effects of scattering the ejected electrons through the spherically symmetric valence shell with similar cross sections for helium, representing a purely two-electron target with an analogous initial-state configuration.

  14. Accumulation of tritium in beryllium material under neutron irradiation

    International Nuclear Information System (INIS)

    In the present work the programming code is created on the basis of which the accumulation kinetics of tritium and isotope of He4 in the Be9 sample is analyzed depending on the time. The program is written in C++ programming language and for the calculations Monte Carlo method was applied. This program scoped on the calculation of concentration of helium and tritium in beryllium samples depending on the spectrum of the neutron flux in different experimental reactors such as JMTR, JOYO and IPEN/MB. The processes of accumulation of helium and tritium for each neutron energy spectrum of these reactors were analyzed. (author)

  15. Microstructure and mechanical properties of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Ishitsuka, E.; Kawamura, H. [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Terai, T.; Tanaka, S.

    1998-01-01

    Microstructure and mechanical properties of the neutron irradiated beryllium with total fast neutron fluences of 1.3 - 4.3 x 10{sup 21} n/cm{sup 2} (E>1 MeV) at 327 - 616degC were studied. Swelling increased by high irradiation temperature, high fluence, and by the small grain size and high impurity. Obvious decreasing of the fracture stress was observed in the bending test and in small grain specimens which had many helium bubbles on the grain boundary. Decreasing of the fracture stress for small grain specimens was presumably caused by crack propagation on the grain boundaries which weekend by helium bubbles. (author)

  16. Measuring capacity building in communities: a review of the literature

    Directory of Open Access Journals (Sweden)

    Liberato Selma C

    2011-11-01

    Full Text Available Abstract Background Although communities have long been exhorted to make efforts to enhance their own health, such approaches have often floundered and resulted in little or no health benefits when the capacity of the community has not been adequately strengthened. Thus being able to assess the capacity building process is paramount in facilitating action in communities for social and health improvement. The current review aims to i identify all domains used in systematically documented frameworks developed by other authors to assess community capacity building; and ii to identify the dimensions and attributes of each of the domains as ascribed by these authors and reassemble them into a comprehensive compilation. Methods Relevant published articles were identified through systematic electronic searches of selected databases and the examination of the bibliographies of retrieved articles. Studies assessing capacity building or community development or community participation were selected and assessed for methodological quality, and quality in relation to the development and application of domains which were identified as constituents of community capacity building. Data extraction and analysis were undertaken using a realist synthesis approach. Results Eighteen articles met the criteria for this review. The various domains to assess community capacity building were identified and reassembled into nine comprehensive domains: "learning opportunities and skills development", "resource mobilization", "partnership/linkages/networking", "leadership", "participatory decision-making", "assets-based approach", "sense of community", "communication", and "development pathway". Six sub-domains were also identified: "shared vision and clear goals", "community needs assessment", "process and outcome monitoring", "sustainability", "commitment to action" and "dissemination". Conclusions The set of domains compiled in this review serve as a foundation for

  17. House dust mite control measures for asthma: systematic review

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C.; Johansen, Helle Krogh

    2008-01-01

    The major allergen in house dust comes from mites. We performed a systematic review of the randomized trials that had assessed the effects of reducing exposure to house dust mite antigens in the homes of people with mite-sensitive asthma, and had compared active interventions with placebo...... improved (relative risk 1.01, 95% CI 0.80-1.27), asthma symptom scores (standardized mean difference -0.04, 95% CI -0.15 to 0.07) or in medication usage (standardized mean difference -0.06, 95% CI -0.18 to 0.07). Chemical and physical methods aimed at reducing exposure to house dust mite allergens cannot...

  18. Patient-reported outcome measures for asthma: a systematic review

    OpenAIRE

    Worth, Allison; Hammersley, Victoria; Knibb, Rebecca; Flokstra-de-Blok, Bertine; DunnGalvin, Audrey; Walker, Samantha; Dubois, Anthony E J; Sheikh, Aziz

    2014-01-01

    Background: Patient-reported outcome measures (PROMs) are measures of the outcome of treatment(s) reported directly by the patient or carer. There is increasing international policy interest in using these to assess the impact of clinical care. Aims: To identify suitably validated PROMs for asthma and examine their potential for use in clinical settings. Methods: We systematically searched MEDLINE, EMBASE and Web of Science databases from 1990 onwards to identify PROMs for asthma. These were ...

  19. Measures of satisfaction with care during labour and birth: a comparative review

    OpenAIRE

    Sawyer, A.; Ayers, S; Abbott, J.; Gyte, G; H. Rabe; Duley, L

    2013-01-01

    Background: satisfaction is the one of the most frequently reported outcome measures for quality of care. Assessment of satisfaction with maternity services is crucial, and psychometrically sound measures are needed if this is to inform health practices. This paper comparatively reviews current measures of satisfaction with care during labour and birth. Methods: A review of the literature was conducted. Studies were located through computerised databases and hand searching references of i...

  20. Breakup branches of Borromean beryllium-9

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R., E-mail: r.smith.3@pgr.bham.ac.uk; Freer, M.; Wheldon, C.; Curtis, N.; Ashwood, N. I.; Barr, M.; Kokalova, Tz.; Malcolm, J. D.; Ziman, V. A. [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham, B15 2TT (United Kingdom); Almaraz-Calderon, S.; Aprahamian, A.; Bucher, B.; Couder, M.; Fang, X.; Jung, F.; Lu, W.; Roberts, A.; Tan, W. P. [Institute for Structure and Nuclear Astrophysics, Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States); Copp, P.; Lesher, S. R. [Department of Physics, University of Wisconsin - La Crosse, La Crosse, WI 54601 (United States); and others

    2015-10-15

    The breakup reaction {sup 9}Be({sup 4}He, 3α)n was measured using an array of four double-sided silicon strip detectors at beam energies of 22 and 26 MeV. Excited states in {sup 9}Be up to 12 MeV were populated and reconstructed through the measurement of the charged reaction products. It is proposed that limits on the spins and parities of the states can be derived from the way that they decay. Various breakup paths for excited states in {sup 9}Be have been explored including the {sup 8}Be{sub g.s.} + n, {sup 8}Be{sub 2{sup +}} + n and {sup 5}He{sub g.s.} + {sup 4}He channels. By imposing the condition that the breakup proceeded via the {sup 8}Be ground state, clean excitation spectra for {sup 9}Be were reconstructed. The remaining two breakup channels were found to possess strongly-overlapping kinematic signatures and more sophisticated methods (referenced) are required to completely disentangle these other possibilities. Emphasis is placed on the development of the experimental analysis and the usefulness of Monte-Carlo simulations for this purpose.

  1. Metallic beryllium-7 target of small diameter

    CERN Document Server

    Zyuzin, A Yu; Vincent, J S; Buckley, K R; Bateman, N P; Snover, K A; Csandjan, J M; Steiger, T D; Adelberger, E G; Swanson, H E

    1999-01-01

    The stellar sup 7 Be(p, gamma) sup 8 B reaction rate has the largest uncertainty among all nuclear reaction rates in the standard solar model. However, the solar neutrino flux predicted for the majority of proposed and existing solar neutrino detectors is directly dependent on the rate of sup 7 Be(p, gamma) sup 8 B reaction. The existing solar neutrino detectors measure rate of sup 8 B decay neutrinos that is too low. This constitutes largely the solar neutrino problem. Existing measurements of the sup 7 Be(p, gamma) sup 8 B reaction rate disagree with one another, indicating the need for more precise experiments. To provide the required targets a new procedure for sup 7 Be production, separation and target manufacturing has been developed. First, a lithium target has been designed for sup 7 Be production at TRIUMF's 13 MeV cyclotron. The lithium target has been extensively tested at 50 mu A proton beam current yielding 8.1 MBq/mu A h of sup 7 Be. An adsorption filtration technique has been developed for sup ...

  2. Aerosol light absorption and its measurement: A review

    International Nuclear Information System (INIS)

    Light absorption by aerosols contributes to solar radiative forcing through absorption of solar radiation and heating of the absorbing aerosol layer. Besides the direct radiative effect, the heating can evaporate clouds and change the atmospheric dynamics. Aerosol light absorption in the atmosphere is dominated by black carbon (BC) with additional, significant contributions from the still poorly understood brown carbon and from mineral dust. Sources of these absorbing aerosols include biomass burning and other combustion processes and dust entrainment. For particles much smaller than the wavelength of incident light, absorption is proportional to the particle volume and mass. Absorption can be calculated with Mie theory for spherical particles and with more complicated numerical methods for other particle shapes. The quantitative measurement of aerosol light absorption is still a challenge. Simple, commonly used filter measurements are prone to measurement artifacts due to particle concentration and modification of particle and filter morphology upon particle deposition, optical interaction of deposited particles and filter medium, and poor angular integration of light scattered by deposited particles. In situ methods measure particle absorption with the particles in their natural suspended state and therefore are not prone to effects related to particle deposition and concentration on filters. Photoacoustic and refractive index-based measurements rely on the heating of particles during light absorption, which, for power-modulated light sources, causes an acoustic signal and modulation of the refractive index in the air surrounding the particles that can be quantified with a microphone and an interferometer, respectively. These methods may suffer from some interference due to light-induced particle evaporation. Laser-induced incandescence also monitors particle heating upon absorption, but heats absorbing particles to much higher temperatures to quantify BC mass

  3. Review of Prior U.S. Attribute Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    White, G K

    2012-07-06

    Attribute Measurement Systems have been developed and demonstrated several times in the United States over the last decade or so; under the Trilateral Initiative (1996-2002), FMTTD (Fissile Material Transparency Technology Demonstration, 2000), and NG-AMS (Next Generation Attribute Measurement System, 2005-2008). Each Attribute Measurement System has contributed to the growing body of knowledge regarding the use of such systems in warhead dismantlement and other Arms Control scenarios. The Trilateral Initiative, besides developing prototype hardware/software, introduced the topic to the international community. The 'trilateral' parties included the United States, the Russian Federation, and the International Atomic Energy Agency (IAEA). With the participation of a Russian delegation, the FMTTD demonstrated that measurements behind an information barrier are feasible while meeting host party security requirements. The NG-AMS system explored the consequences of maximizing the use of Commercial off the Shelf (COTS) equipment, which made construction easier, but authentication harder. The 3rd Generation Attribute Measurement System (3G-AMS) will further the scope of previous systems by including additional attributes and more rigor in authentication.

  4. The mechanism for production of beryllium fluoride from the product of ammonium fluoride processing of beryllium- containing raw material

    Science.gov (United States)

    Kraydenko, R. I.; Dyachenko, A. N.; Malyutin, L. N.; Petlin, I. V.

    2016-06-01

    The technique of fluorite-phenacite-bertrandite ores from Russian Ermakovskoe deposit processing by ammonium bifluoride is described. To determine the temperature mode and the thermal dissociation mechanism of ammonium tetrafluoroberyllate (the product of ammonium-fluoride leaching of the ore) the TG/DTA have been carried out. By IR spectroscopy and XRD the semi-products of ammonium tetrafluoroberyllate thermal dissociation have been identified. The hygroscopic low-temperature beryllium fluoride forms higher than 380°C. The less hydroscopic form of BeF2 have been produced at 600°C.

  5. Lava effusion rate definition and measurement--A review

    Science.gov (United States)

    Calvari, Sonia; Dehn, Jonathan; Harris, A.

    2007-01-01

    Measurement of effusion rate is a primary objective for studies that model lava flow and magma system dynamics, as well as for monitoring efforts during on-going eruptions. However, its exact definition remains a source of confusion, and problems occur when comparing volume flux values that are averaged over different time periods or spatial scales, or measured using different approaches. Thus our aims are to: (1) define effusion rate terminology; and (2) assess the various measurement methods and their results. We first distinguish between instantaneous effusion rate, and time-averaged discharge rate. Eruption rate is next defined as the total volume of lava emplaced since the beginning of the eruption divided by the time since the eruption began. The ultimate extension of this is mean output rate, this being the final volume of erupted lava divided by total eruption duration. Whether these values are total values, i.e. the flux feeding all flow units across the entire flow field, or local, i.e. the flux feeding a single active unit within a flow field across which many units are active, also needs to be specified. No approach is without its problems, and all can have large error (up to ∼50%). However, good agreement between diverse approaches shows that reliable estimates can be made if each approach is applied carefully and takes into account the caveats we detail here. There are three important factors to consider and state when measuring, giving or using an effusion rate. First, the time-period over which the value was averaged; second, whether the measurement applies to the entire active flow field, or a single lava flow within that field; and third, the measurement technique and its accompanying assumptions.

  6. A review on recent upper atmosphere atomic oxygen measurements

    Science.gov (United States)

    Kaufmann, Martin; Ern, Manfred; Riese, Martin; Zhu, Yajun

    2016-07-01

    Atomic oxygen is a key player in the upper mesosphere lower and thermosphere chemistry, energy balance, and dynamics. In recent years, a few new global datasets of this species have been presented. They are based on airglow measurements from low earth satellites. Surprisingly, the atomic oxygen abundance differs by 30-50% for similar atmospheric conditions. This paper gives an overview on the various atomic oxygen datasets available so far and presents most recent results obtained from measurements of the SCIAMACHY instrument on Envisat. Differences between the datasets are discussed.

  7. NSSS aging review: critical systems operating measures and monitoring

    International Nuclear Information System (INIS)

    How long the nuclear plants can get. In this question we can find three main aspects: Economic - Licensing - and Technical ones. The final answer to this question will include compulsory elements coming from these three areas, each of them being a deciding factor. The presentation is focused on the technical aspect; but before a few comments are done on economic and licensing factors. Then, some particular technical items dealing with aging or life time of our nuclear plants are reviewed: electrical equipment, heat exchangers (steam generators), wear: primary pump, embrittlement: Reactor Pressure Vessel (Austeno-ferritic parts), fatigue (Thermo-hydraulic transients). By the way, some information about how this problem is handled, at the present time, explicitely or implicitely in France are given

  8. Measurement errors and scaling relations in astrophysics: a review

    CERN Document Server

    Andreon, S

    2012-01-01

    This review article considers some of the most common methods used in astronomy for regressing one quantity against another in order to estimate the model parameters or to predict an observationally expensive quantity using trends between object values. These methods have to tackle some of the awkward features prevalent in astronomical data, namely heteroscedastic (point-dependent) errors, intrinsic scatter, non-ignorable data collection and selection effects, data structure and non-uniform population (often called Malmquist bias), non-Gaussian data, outliers and mixtures of regressions. We outline how least square fits, weighted least squares methods, Maximum Likelihood, survival analysis, and Bayesian methods have been applied in the astrophysics literature when one or more of these features is present. In particular we concentrate on errors-in-variables regression and we advocate Bayesian techniques.

  9. Influence of neutron irradiation on the tritium retention in beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Rolli, R.; Ruebel, S.; Werle, H. [Forschungszentrum Karlsruhe, Inst. fuer Neutronenphysik und Reaktortechnik, Karlsruhe (Germany); Wu, C.H.

    1998-01-01

    Carbon-based materials and beryllium are the candidates for protective layers on the components of fusion reactors facing plasma. In contact with D-T plasma, these materials absorb tritium, and it is anticipated that tritium retention increases with the neutron damage due to neutron-induced traps. Because of the poor data base for beryllium, the work was concentrated on it. Tritium was loaded into the samples from stagnant T{sub 2}/H{sub 2} atmosphere, and afterwards, the quantity of the loaded tritium was determined by purged thermal annealing. The specification of the samples is shown. The samples were analyzed by SEM before and after irradiation. The loading and the annealing equipments are contained in two different glove boxes with N{sub 2} inert atmosphere. The methods of loading and annealing are explained. The separation of neutron-produced and loaded tritium and the determination of loaded tritium in irradiated samples are reported. Also the determination of loaded tritium in unirradiated samples is reported. It is evident that irradiated samples contained much more loaded tritium than unirradiated samples. The main results of this investigation are summarized in the table. (K.I.)

  10. Remarkable Hydrogen Storage on Beryllium Oxide Clusters: First Principles Calculations

    CERN Document Server

    Shinde, Ravindra

    2016-01-01

    Since the current transportation sector is the largest consumer of oil, and subsequently responsible for major air pollutants, it is inevitable to use alternative renewable sources of energies for vehicular applications. The hydrogen energy seems to be a promising candidate. To explore the possibility of achieving a solid-state high-capacity storage of hydrogen for onboard applications, we have performed first principles density functional theoretical calculations of hydrogen storage properties of beryllium oxide clusters (BeO)$_{n}$ (n=2 -- 8). We observed that polar BeO bond is responsible for H$_{2}$ adsorption. The problem of cohesion of beryllium atoms does not arise, as they are an integral part of BeO clusters. The (BeO)$_{n}$ (n=2 -- 8) adsorbs 8--12 H$_{2}$ molecules with an adsorption energy in the desirable range of reversible hydrogen storage. The gravimetric density of H$_{2}$ adsorbed on BeO clusters meets the ultimate 7.5 wt% limit, recommended for onboard practical applications. In conclusion,...

  11. Microstructural Characterization of Beryllium Treated Al-Si Alloys

    Directory of Open Access Journals (Sweden)

    M. F. Ibrahim

    2015-01-01

    Full Text Available The present study was carried out on B356 and B357 alloys using the thermal analysis technique. Metallographic samples prepared from these castings were examined using optical microscopy and FESEM. Results revealed that beryllium causes partial modification of the eutectic Si, similar to that reported for magnesium additions. Addition of 0.8 wt.% Mg reduces the eutectic temperature by ~10°C. During solidification of alloys containing high levels of Fe and Mg, but no Sr, formation of a Be-Fe phase was detected at 611°C, close to that of α-Al. The Be-Fe phase precipitates in script-like form at or close to the β-Al5SiFe platelets. A new reaction, composed of fine particles of Si and π-Fe phase, was observed to occur near the end of solidification in high Mg-, high Fe-, and Be-containing alloys. The amount of this reaction decreased with the addition of Sr. Occasionally, Be-containing phase particles were observed as part of the reaction. Addition of Be has a noticeable effect on decreasing the β-Al5FeSi platelet length; this effect may be enhanced by addition of Sr. Beryllium addition also results in precipitation of the β-Al5FeSi phase in nodular form, which lowers its harmful effects on the alloy mechanical properties.

  12. United Kingdom Beryllium Registry: mortality and autopsy study.

    Science.gov (United States)

    Williams, W J

    1996-01-01

    This report is based on 30 deaths from chronic beryllium disease (CBD) in the United Kingdom with details of 19 autopsies. The majority were fluorescent lamp workers and machinists who died from respiratory failure. There were no cases of lung cancer. The survival times ranged from less than 1 to 29 years and was longest in machinists. All of the workers showed interstitial pulmonary fibrosis with varying degrees of cystic change. The majority showed hyalinized, and a few active sarcoid-type, granulomas. Extrathoracic granulomas, as in a U.K. sarcoid autopsy series, were rare. A notable difference was the absence of myocardial involvement in CBD compared to an incidence of 20% in the sarcoid autopsies. The detection of beryllium in the criteria for diagnosis is emphasized and the cases classified as definite include 12 of 19 positive analysis, 6 of 19, negative or unavailable analysis. The remaining case was classified as dubious because, despite a positive analysis, granulomas were absent. The main differential diagnosis is sarcoidosis. Images Figure 1. Figure 2. Figure 3. PMID:8933040

  13. A non-chemical spectroscopic determination of atmospheric beryllium

    International Nuclear Information System (INIS)

    Beryllium in the atmosphere is determined by emission spectroscopy using a non-chemical method of analysis. Long term effects of beryllium poisoning result in respiratory and skin disease, and this is partly reflected by the low threshold limits (0.002 mg/m3). In comparison the threshhold values for lead and cadmium are 0.2 and 0.16 mg/m3 respectively. Air samples are collected at 2 litres/ minute using cellulose filters, and sampling time is dependent on the individual process being monitored, but can be as short as five minutes, eg. dental laboratories. The filters are initially divided in two parts, and one portion is carefully pelletised using a steel press. The pellet is placed in an electrode cup and 'wetted' using isopropanol and ethylene glycol. Wetting is necessary because the pellets tended to explode out of the arcing zone. Calibration graphs were produced using an internal cobalt standard, and the 234.8 nm, 313.0 nm emission lines were used. No spectral and inter-element effects were observed, and the minimum detection limit was one nanogram. Under normal working conditions a 25% precision was obtained. (author)

  14. Calculations for electron-impact excitation and ionization of beryllium

    CERN Document Server

    Zatsarinny, Oleg; Fursa, Dmitry V; Bray, Igor

    2016-01-01

    The B-spline R-matrix and the convergent close-coupling methods are used to study electron collisions with neutral beryllium over an energy range from threshold to 100 eV. Coupling to the target continuum significantly affects the results for transitions from the ground state, but to a lesser extent the strong transitions between excited states. Cross sections are presented for selected transitions between low-lying physical bound states of beryllium, as well as for elastic scattering, momentum transfer, and ionization. The present cross sections for transitions from the ground state from the two methods are in excellent agreement with each other, and also with other available results based on nonperturbative convergent pseudo-state and time-dependent close-coupling models. The elastic cross section at low energies is dominated by a prominent shape resonance. The ionization from the $(2s2p)^3P$ and $(2s2p)^1P$ states strongly depends on the respective term. The current predictions represent an extensive set o...

  15. Review Article: Structural flood-protection measures referring to several European case studies

    Science.gov (United States)

    Kryžanowski, A.; Brilly, M.; Rusjan, S.; Schnabl, S.

    2014-01-01

    The paper presents a review of structural measures that were taken to cope with floods in some cities along the Danube River, such as Vienna, Bratislava, and Belgrade. These cities were also considered as case studies within the KULTURisk project. The structural measures are reviewed and compared to each other according to the type, duration of application, the return period of the design flood event, how the project measures are integrated into spatial planning and the problems that occur in the flood defences today. Based on this review, some suggestions are given on how to improve the flood risk management in flood-prone areas.

  16. Dissolution of FB-Line Residues Containing Beryllium Metal

    Energy Technology Data Exchange (ETDEWEB)

    RUDISILL, TRACY S.; CROWDER, MARK L.

    2005-09-06

    Scrap materials containing plutonium (Pu) metal were dissolved at the Savannah River Site (SRS) as part of a program to disposition nuclear materials during the deactivation of the FB-Line facility. Some of these items contained both Pu and beryllium (Be) metal as a composite material. The Pu and Be metals were physically separated to minimize the amount of Be associated with the Pu; however, a dissolution flowsheet was required to dissolve small amounts of Be combined with the Pu metal using a dissolving solution containing nitric acid (HNO{sub 3}) and potassium fluoride (KF). Since the dissolution of Pu metal in HNO{sub 3}/fluoride (F{sup -}) solutions was well understood, the primary focus of the flowsheet development was the dissolution of Be metal. Initially, small-scale experiments were used to measure the dissolution rate of Be metal foils using conditions effective for the dissolution of Pu metal. The experiments demonstrated that the dissolution rate was nearly independent of the HNO{sub 3} concentration over the limited range of investigation and only a moderate to weak function of the F{sup -} concentration. The effect of temperature was more pronounced, significantly increasing the dissolution rate between 40 and 105 C. The offgas analysis from three Be metal foil dissolutions demonstrated that the production of hydrogen (H{sub 2}) was sensitive to the HNO{sub 3} concentration, decreasing by a factor of approximately two when the concentration was increased from 4 to 8 M. In subsequent experiments, complete dissolution of Be samples from a Pu/Be composite material was achieved in a 4 M HNO{sub 3} solution containing 0.1-0.2 M KF. Gas samples collected during each experiment showed that the maximum H{sub 2} generation rate occurred at temperatures below 70-80 C. A Pu metal dissolution experiment was performed using a 4 M HNO{sub 3}/0.1 M KF solution at 80 C to demonstrate flowsheet conditions developed for the dissolution of Be metal. As the reaction

  17. Outcome instruments to measure frailty: a systematic review

    NARCIS (Netherlands)

    Vries, N.M. de; Staal, J.B.; Ravensberg, C.D. van; Hobbelen, J.S.; Olde Rikkert, M.G.M.; Nijhuis-Van der Sanden, M.W.G.

    2011-01-01

    Frailty is one of the greatest challenges for healthcare professionals. The level of frailty depends on several interrelated factors and can change over time while different interventions seem to be able to influence the level of frailty. Therefore, an outcome instrument to measure frailty with soun

  18. A Narrative Review of Generic Intervention Fidelity Measures

    Science.gov (United States)

    Di Rezze, Briano; Law, Mary; Gorter, Jan Willem; Eva, Kevin; Pollock, Nancy

    2012-01-01

    To increase the rigor of pediatric rehabilitation research, there is a need to evaluate the degree to which an intervention is conducted as planned (i.e., fidelity). Generic fidelity measures evaluate more than one intervention and often include nonspecific attributes of the therapy process common to both interventions. The objective of this study…

  19. A review of international sources for road safety measures assessment.

    NARCIS (Netherlands)

    Yannis, G. Weijermars, W. & Kauppila, J.

    2012-01-01

    The efficiency assessment of road safety measures is considered to be an extremely useful tool in decision making; in particular, cost-benefit and cost-effectiveness analyses are carried out in several countries, in a more or less systematic way. The objective of this paper is to present findings fr

  20. Measuring solar reflectance Part II: Review of practical methods

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, Ronnen; Akbari, Hashem; Berdahl, Paul

    2010-05-14

    A companion article explored how solar reflectance varies with surface orientation and solar position, and found that clear sky air mass 1 global horizontal (AM1GH) solar reflectance is a preferred quantity for estimating solar heat gain. In this study we show that AM1GH solar reflectance R{sub g,0} can be accurately measured with a pyranometer, a solar spectrophotometer, or an updated edition of the Solar Spectrum Reflectometer (version 6). Of primary concern are errors that result from variations in the spectral and angular distributions of incident sunlight. Neglecting shadow, background and instrument errors, the conventional pyranometer technique can measure R{sub g,0} to within 0.01 for surface slopes up to 5:12 [23{sup o}], and to within 0.02 for surface slopes up to 12:12 [45{sup o}]. An alternative pyranometer method minimizes shadow errors and can be used to measure R{sub g,0} of a surface as small as 1 m in diameter. The accuracy with which it can measure R{sub g,0} is otherwise comparable to that of the conventional pyranometer technique. A solar spectrophotometer can be used to determine R*{sub g,0}, a solar reflectance computed by averaging solar spectral reflectance weighted with AM1GH solar spectral irradiance. Neglecting instrument errors, R*{sub g,0} matches R{sub g,0} to within 0.006. The air mass 1.5 solar reflectance measured with version 5 of the Solar Spectrum Reflectometer can differ from R*{sub g,0} by as much as 0.08, but the AM1GH output of version 6 of this instrument matches R*{sub g,0} to within about 0.01.

  1. Thermal desorption of deuterium implanted into beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Markin, A.V.; Chernikov, V.N.; Zakharov, A.P. [Institute of Physical Chemistry, Moscow (Russian Federation)] [and others

    1995-09-01

    By means of TDS measurements it is shown that the desorption of deuterium from Be implanted with 5 keV D ions to fluences, {Phi}, from 1x10{sup 20} D/m{sup 2} to 1x10{sup 21} D/m{sup 2} proceeds in one high temperature stage B, while at {Phi} {ge} 1.2x10{sup 21}D/m{sup 2} one more stage A is added. The desorption maximum A is narrow and consists of two peaks A{sub 1} and A{sub 2} at about 460 K and 490 K, respectively. Peak A{sub 1} is attributed to the desorption of deuterium from the walls of opened channels formed under D ion implantation. Peak {sub A}2 is a consequence of the opening of a part of closed bubbles/channels to the outer surface. The position of maximum B shifts noticeably and nonsteadily on the fluence in a range from 850 to 1050 K. The origin of this maximum is the liberation of D atoms bound at vacancy complexes discussed previously by Wampler. The dependence of Tm(B) on the fluence is governed by the interaction of freely migrating D atoms with partly opened or fully closed gas cavity arrangements which are created under temperature ramping, but differently in specimens implanted with D ions to different fluences.

  2. Measurement of G Using a Cryogenic Torsion Pendulum: Post-2008 Analysis Review

    Directory of Open Access Journals (Sweden)

    Newman Riley

    2014-06-01

    Full Text Available A measurement of G by our University of California, Irvine (UCI team was reported at the 2008 Conference on Precision Electromagnetic Measurements (CPEM [1]. This work has not yet been published; work continues to review and refine analysis of data from that measurement. We present in this paper the analysis and results of the measurement as it stood at the time of the 2008 conference, and discuss the analysis review under way. Our G measurement was conducted “blind”, keeping the exact value of the source mass hidden until just before the conference presentation.

  3. Use of Beryllium-7 as a surrogate to determine the deposition of metal and polycyclic aromatic hydrocarbon through urban aerosols in Nantes, France

    OpenAIRE

    Percot, Stéphane; Ruban, Véronique; Roupsard, Pierre; Maro, Denis; MILLET, Maurice

    2013-01-01

    The aerodynamic size distribution of the natural radionuclide Beryllium 7 (7Be) and associated trace metals, pesticides and polycyclic aromatic hydrocarbons (PAHs) in Nantes (France) was determined during 6 campaigns (conducted from June 2010 to March 2012) using a low pressure impactor. The activity distribution of 7Be, as measured by a gamma ray spectrometer, was associated with the accumulation mode (with around 85% of the mass < 1 µm) and explained by post condensation processes on the ai...

  4. Summary measures for clinical gait analysis: a literature review.

    Science.gov (United States)

    Cimolin, Veronica; Galli, Manuela

    2014-04-01

    Instrumented 3D-gait analysis (3D-GA) is an important method used to obtain information that is crucial for establishing the level of functional limitation due to pathology, observing its evolution over time and evaluating rehabilitative intervention effects. However, a typical 3D-GA evaluation produces a vast amount of data, and despite its objectivity, its use is complicated, and the data interpretation is difficult. It is even more difficult to obtain an overview on patient cohorts for a comparison. Moreover, there is a growing awareness of the need for a concise index, specifically, a single measure of the 'quality' of a particular gait pattern. Several gait summary measures, which have been used in conjunction with 3D-GA, have been proposed to objectify clinical impression, quantify the degree of gait deviation from normal, stratify the severity of pathology, document the changes in gait patterns over time and evaluate interventions.

  5. Criteria for Affordable Housing Performance Measurement: A Review

    Directory of Open Access Journals (Sweden)

    Esruq-Labin A.M.J.

    2014-01-01

    Full Text Available A home is one of the basic human needs, thus a new concept known as Grow Home has risen. This concept was established to encourage more families to buy their own houses. The Grow Home concept is based on the notion of affordable housing. This paper aims to explore a proposal for affordable housing measurement with six assessment components. In other words, this work intends to study factors that can affect affordable housing assessment. In this paper, we investigated the 20 criteria for affordable housing assessment given by Mulliner and Maliene in their study. Then, we rearranged these criteria into five components, and added the Grow Home component. Each component has different criteria. Finally, six affordable housing measurement components are identified, namely, income ratios, loans and accommodations, facilities and services, safety and comfort, quality management, and Grow Home. These components are also considered as main factors that directly affect affordable housing. This study aspires to contribute to existing literature by proposing six assessment components as a measurement of affordable housing.

  6. The development and advantages of beryllium capsules for the National Ignition Facility

    International Nuclear Information System (INIS)

    Capsules with beryllium ablators have long been considered as alternatives to plastic for the National Ignition Facility laser; now the superior performance of beryllium is becoming well substantiated. Beryllium capsules have the advantages of relative insensitivity to instability growth, low opacity, high tensile strength, and high thermal conductivity. 3-D calculation with the HYDRA code NTIS Document No. DE-96004569 (M. M. Marinak et.al. in UCRL-LR-105821-95-3) confirm 2-D LASNEX U. B. Zimmerman and W. L. Kruer, Comments Plasmas Phys. Controlled Thermonucl. Fusion, 2, 51(2975) results that particular beryllium capsule designs are several times less sensitive than the CH point design to instability growth from DT ice roughness. These capsule designs contain more ablator mass and leave some beryllium unablated at ignition. By adjusting the level of copper dopant, the unablated mass can increase or decrease, with a corresponding decrease or increase in sensitivity to perturbations. A plastic capsule with the same ablator mass as the beryllium and leaving the same unablated mass also shows this reduced perturbation sensitivity. Beryllium's low opacity permits the creation of 250 eV capsule designs. Its high tensile strength allows it to contain DT fuel at room temperature. Its high thermal conductivity simplifies cryogenic fielding

  7. Epicardial Fat: Definition, Measurements and Systematic Review of Main Outcomes

    International Nuclear Information System (INIS)

    Epicardial fat (EF) is a visceral fat deposit, located between the heart and the pericardium, which shares many of the pathophysiological properties of other visceral fat deposits, It also potentially causes local inflammation and likely has direct effects on coronary atherosclerosis. Echocardiography, computed tomography and magnetic resonance imaging have been used to evaluate EF, but variations between methodologies limit the comparability between these modalities. We performed a systematic review of the literature finding associations of EF with metabolic syndrome and coronary artery disease. The summarization of these associations is limited by the heterogeneity of the methods used and the populations studied, where most of the subjects were at high cardiovascular disease risk. EF is also associated with other known factors, such as obesity, diabetes mellitus, age and hypertension, which makes the interpretation of its role as an independent risk marker intricate. Based on these data, we conclude that EF is a visceral fat deposit with potential implications in coronary artery disease. We describe the reference values of EF for the different imaging modalities, even though these have not yet been validated for clinical use. It is still necessary to better define normal reference values and the risk associated with EF to further evaluate its role in cardiovascular and metabolic risk assessment in relation to other criteria currently used

  8. Epicardial Fat: Definition, Measurements and Systematic Review of Main Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Bertaso, Angela Gallina [Programa de Pós-Graduação em Ciências da Saúde: Cardiologia e Ciências Cardiovasculares - Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil); Bertol, Daniela [Programa de Pós-Graduação em Epidemiologia - Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil); Duncan, Bruce Bartholow; Foppa, Murilo, E-mail: mfoppa@cardiol.br [Programa de Pós-Graduação em Ciências da Saúde: Cardiologia e Ciências Cardiovasculares - Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil); Programa de Pós-Graduação em Epidemiologia - Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil)

    2013-07-15

    Epicardial fat (EF) is a visceral fat deposit, located between the heart and the pericardium, which shares many of the pathophysiological properties of other visceral fat deposits, It also potentially causes local inflammation and likely has direct effects on coronary atherosclerosis. Echocardiography, computed tomography and magnetic resonance imaging have been used to evaluate EF, but variations between methodologies limit the comparability between these modalities. We performed a systematic review of the literature finding associations of EF with metabolic syndrome and coronary artery disease. The summarization of these associations is limited by the heterogeneity of the methods used and the populations studied, where most of the subjects were at high cardiovascular disease risk. EF is also associated with other known factors, such as obesity, diabetes mellitus, age and hypertension, which makes the interpretation of its role as an independent risk marker intricate. Based on these data, we conclude that EF is a visceral fat deposit with potential implications in coronary artery disease. We describe the reference values of EF for the different imaging modalities, even though these have not yet been validated for clinical use. It is still necessary to better define normal reference values and the risk associated with EF to further evaluate its role in cardiovascular and metabolic risk assessment in relation to other criteria currently used.

  9. Instrumented Measurement of Balance and Postural Control in Individuals with Lower Limb Amputation: A Critical Review

    Science.gov (United States)

    Jayakaran, Prasath; Johnson, Gillian M.; Sullivan, S. John; Nitz, Jennifer C.

    2012-01-01

    Measurement of balance and postural performance that underpins activities of daily living is important in the rehabilitation of individuals with a lower limb amputation (LLA), and there are a number of methods and strategies available for this purpose. To provide an evidence-based choice of approach, this review aims to critically review the tasks…

  10. A Review for Model Plant Mismatch Measures in Process Monitoring

    Institute of Scientific and Technical Information of China (English)

    王洪; 谢磊; 宋执环

    2012-01-01

    Model is usually necessary for the design of a control loop. Due to simplification and unknown dynamics, model plant mismatch is inevitable in the control loop. In process monitoring, detection of mismatch and evaluation of its influences are demanded. In this paper several mismatch measures are presented based on different model descriptions. They are categorized into different groups from different perspectives and their potential in detection and diagnosis is evaluated. Two case studies on mixing process and distillation process demonstrate the efficacy of the framework of mismatch monitoring.

  11. Acoustic doppler methods for remote measurements of ocean flows - a review

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The evolution of acoustic doppler methods for remote measurements of ocean flows has been briefly reviewed in historical perspective. Both Eulerian and profiling methods have been discussed. Although the first acoustic Doppler current meter has been...

  12. Measuring Emotions Toward Wildlife: A Review of Generic Methods and Instruments

    NARCIS (Netherlands)

    Jacobs, M.H.; Fehres, P.; Campbell, M.

    2012-01-01

    Researchers are recognizing the importance of studying emotions for understanding human–wildlife interactions. This article reviews generic methods and instruments for assessing emotions, as developed within the affective sciences. Four broad categories of emotion measures can be distinguished: (a)

  13. Experiences of mental illness stigma, prejudice and discrimination: a review of measures

    Directory of Open Access Journals (Sweden)

    Clement Sarah

    2010-03-01

    Full Text Available Abstract Background There has been a substantial increase in research on mental illness related stigma over the past 10 years, with many measures in use. This study aims to review current practice in the survey measurement of mental illness stigma, prejudice and discrimination experienced by people who have personal experience of mental illness. We will identify measures used, their characteristics and psychometric properties. Method A narrative literature review of survey measures of mental illness stigma was conducted. The databases Medline, PsychInfo and the British Nursing Index were searched for the period 1990-2009. Results 57 studies were included in the review. 14 survey measures of mental illness stigma were identified. Seven of the located measures addressed aspects of perceived stigma, 10 aspects of experienced stigma and 5 aspects of self-stigma. Of the identified studies, 79% used one of the measures of perceived stigma, 46% one of the measures of experienced stigma and 33% one of the measures of self-stigma. All measures presented some information on psychometric properties. Conclusions The review was structured by considering perceived, experienced and self stigma as separate but related constructs. It provides a resource to aid researchers in selecting the measure of mental illness stigma which is most appropriate to their purpose.

  14. Measuring a caring culture in hospitals: a systematic review of instruments

    OpenAIRE

    Hesselink, G.J.; Kuis, E.; Pijnenburg, M.A.; Wollersheim, H.C.

    2013-01-01

    OBJECTIVE: To identify instruments or components of instruments that aim to measure aspects of a caring culture-shared beliefs, norms and values that direct professionals and managers to act caring in hospitals, and to evaluate their psychometric properties. DESIGN: Systematic review. DATA SOURCES: PubMed, CINAHL, EMBASE, PsychInfo, Web of Science and the International bibliography of the Social Sciences. STUDY SELECTION: Peer-reviewed articles describing (components of) instruments measuring...

  15. Radon decay product in-door behaviour - parameter, measurement method, and model review

    International Nuclear Information System (INIS)

    This report reviews parameters used to characterize indoor radon daughter behavior and concentrations. Certain parameters that affect indoor radon daughter concentrations are described and the values obtained experimentally or theoretically are summarized. Radon daughter measurement methods are reviewed, such as, PAEC, unattached daughters, particle size distributions, and plateout measurement methods. In addition, certain radon pressure driven/diffusion models and indoor radon daughter models are briefly described. (orig.)

  16. The structure and the Raman vibrational spectrum of the beryllium aquacation.

    Science.gov (United States)

    Rozmanov, Dmitry A; Sizova, Olga V; Skripkin, Mikhail Yu; Burkov, Kim A

    2005-11-01

    The experimental Raman vibrational spectrum of the 5.94 m water solution of the beryllium(II) chloride has been acquired. Theoretical frequencies, infrared and Raman intensities of the vibrational spectrum of the beryllium cation tetrahydrate have been calculated by means of quantum chemical approach. The peaks of the experimental spectrum have been assigned on the basis of the results of the quantum-chemical calculations. It has been shown that the hydrating surrounding of the aquacation increases effectively the frequency of the beryllium-oxygen stretching vibration by 16% in comparison with the free complex.

  17. Conditions for preparation of ultrapure beryllium by electrolytic refining in molten alkali-metal chlorides

    Energy Technology Data Exchange (ETDEWEB)

    Wohlfarth, Hagen

    1982-02-01

    Electrolytic refining is regarded as the most suitable process for the production of beryllium with impurity contents below 1 at.-ppM. Several parameters are important for electrolytic refining of beryllium in a BeCl/sub 2/-containing LiCl-KCl melt: current density, BeCl/sub 2/ content, electrolyte temperature, composition of the unpurified beryllium and impurity-ion concentrations in the melt, as well as apparatus characteristics such as rotation speed of the cathode and condition of the crucible material. These factors were studied and optimized such that extensive removal of the maximum number of accompanying and alloying elements was achieved.

  18. Study of beryllium redeposition under bombardment by high intensity -low energy- hydrogen ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Gureev, V.M.; Guseva, M.I.; Danelyan, L.S. [Russian Research Centre Kurchatov Inst., Moscow (Russian Federation)] [and others

    1998-01-01

    The results of studying the erosion of beryllium under an effect of intense ion fluxes with the energy of 250 eV, at the fluences {approx}10{sup 2}1 cm{sup -2}, at the MAGRAS-stand are given. The operating conditions under which a practically-complete redeposition of the sputtered beryllium upon the target surface were experimentally-realized. A change in the microstructure of a beryllium target under sputtering and redeposition is analyzed. Some technological applications are considered. (author)

  19. Measuring factors affecting implementation of health innovations: a systematic review of structural, organizational, provider, patient, and innovation level measures

    OpenAIRE

    Chaudoir, Stephenie R.; Dugan, Alicia G; Barr, Colin HI

    2013-01-01

    Background Two of the current methodological barriers to implementation science efforts are the lack of agreement regarding constructs hypothesized to affect implementation success and identifiable measures of these constructs. In order to address these gaps, the main goals of this paper were to identify a multi-level framework that captures the predominant factors that impact implementation outcomes, conduct a systematic review of available measures assessing constructs subsumed within these...

  20. HOW TO MEASURE HUMAN CAPITAL: A SHORT REVIEW

    Directory of Open Access Journals (Sweden)

    Bálint BALOGH

    2013-06-01

    Full Text Available This paper focuses on the most important estimation approaches of human capital. These approaches can be labeled as either monetary or non-monetary methods of estimation. The three major monetary methods of human capital are the prospective method, the retrospective method and the integrated approach. The income-based approach (prospective method estimates human capital based on the present value of a person’s future income stream. The cost-based approach (retrospective method is centered on the “production” costs of human capital, trying to determine the costs of producing human capital by adding up the education and schooling costs. The integrated approach is a mixture of the prospective and retrospective method. On the other side, the non-monetary measures are essentially education-based indicators, such as the literacy rate, the school enrollment rate or the average years of education.

  1. Photoluminescence enhancement from GaN by beryllium doping

    Science.gov (United States)

    García-Gutiérrez, R.; Ramos-Carrazco, A.; Berman-Mendoza, D.; Hirata, G. A.; Contreras, O. E.; Barboza-Flores, M.

    2016-10-01

    High quality Be-doped (Be = 0.19 at.%) GaN powder has been grown by reacting high purity Ga diluted alloys (Be-Ga) with ultra high purity ammonia in a horizontal quartz tube reactor at 1200 °C. An initial low-temperature treatment to dissolve ammonia into the Ga melt produced GaN powders with 100% reaction efficiency. Doping was achieved by dissolving beryllium into the gallium metal. The powders synthesized by this method regularly consist of two particle size distributions: large hollow columns with lengths between 5 and 10 μm and small platelets in a range of diameters among 1 and 3 μm. The GaN:Be powders present a high quality polycrystalline profile with preferential growth on the [10 1 bar 1] plane, observed by means of X-ray diffraction. The three characteristics growth planes of the GaN crystalline phase were found by using high resolution TEM microscopy. The optical enhancing of the emission in the GaN powder is attributed to defects created with the beryllium doping. The room temperature photoluminescence emission spectra of GaN:Be powders, revealed the presence of beryllium on a shoulder peak at 3.39 eV and an unusual Y6 emission at 3.32eV related to surface donor-acceptor pairs. Also, a donor-acceptor-pair transition at 3.17 eV and a phonon replica transition at 3.1 eV were observed at low temperature (10 K). The well-known yellow luminescence band coming from defects was observed in both spectra at room and low temperature. Cathodoluminescence emission from GaN:Be powders presents two main peaks associated with an ultraviolet band emission and the yellow emission known from defects. To study the trapping levels related with the defects formed in the GaN:Be, thermoluminescence glow curves were obtained using UV and β radiation in the range of 50 and 150 °C.

  2. Failure prediction of thin beryllium sheets used in spacecraft structures

    Science.gov (United States)

    Roschke, Paul N.; Mascorro, Edward; Papados, Photios; Serna, Oscar R.

    1991-01-01

    The primary objective of this study is to develop a method for prediction of failure of thin beryllium sheets that undergo complex states of stress. Major components of the research include experimental evaluation of strength parameters for cross-rolled beryllium sheet, application of the Tsai-Wu failure criterion to plate bending problems, development of a high order failure criterion, application of the new criterion to a variety of structures, and incorporation of both failure criteria into a finite element code. A Tsai-Wu failure model for SR-200 sheet material is developed from available tensile data, experiments carried out by NASA on two circular plates, and compression and off-axis experiments performed in this study. The failure surface obtained from the resulting criterion forms an ellipsoid. By supplementing experimental data used in the the two-dimensional criterion and modifying previously suggested failure criteria, a multi-dimensional failure surface is proposed for thin beryllium structures. The new criterion for orthotropic material is represented by a failure surface in six-dimensional stress space. In order to determine coefficients of the governing equation, a number of uniaxial, biaxial, and triaxial experiments are required. Details of these experiments and a complementary ultrasonic investigation are described in detail. Finally, validity of the criterion and newly determined mechanical properties is established through experiments on structures composed of SR200 sheet material. These experiments include a plate-plug arrangement under a complex state of stress and a series of plates with an out-of-plane central point load. Both criteria have been incorporated into a general purpose finite element analysis code. Numerical simulation incrementally applied loads to a structural component that is being designed and checks each nodal point in the model for exceedance of a failure criterion. If stresses at all locations do not exceed the failure

  3. Modes of Occurrence and Geological Origin of Beryllium in Coals from the Pu'an Coalfield, Guizhou, Southwest China

    Institute of Scientific and Technical Information of China (English)

    YANG Jianye

    2007-01-01

    The concentration, modes of occurrence and geological origin of beryllium in five workable coal beds from the Pu'an Coalfield of Guizbou were studied using the inductively coupled-plasma mass spectrometry (ICP-MS), floating and sinking experiments (FSE) and sequential chemical extraction procedures (SCEP). The results show that the average concentration of beryllium in coals from the Pu'an Coalfield is 1.54 μg/g, much lower than that in most Chinese and worldwide coals.Beryllium in the Pu'an coals was not significantly enriched. However, it should be noted that the No. 8 coal bed from the study area has a high concentration of beryllium, 6.89 μg/g, three times higher than the background value of beryllium in coal. Beryllium in coal mainly occurs as organic association and has predominantly originated from coal-forming plants when its concentration is relatively low. The concentration of beryllium occurring as organic association is close to that distributed in inorganic matter when beryllium concentration of coal is similar to its background value, and in addition to coal-forming plants, beryllium is mainly derived from detrital materials of terrigenous origin. When beryllium is anomalously enriched in coal, it mainly occurs as organic association and is derived from volcanic tonsteins leached for a long geological time and then adsorbed by organic matter in peat mire.

  4. Thermal desorption analysis of beryllium tile pieces from JET

    International Nuclear Information System (INIS)

    Pieces of beryllium tile exposed to a D-D plasma in JET have been studied by thermal desorption spectroscopy. These tiles have a thick layer of redeposited Be-C-O with considerable hydrogen and deuterium present. The samples were heated at a constant rate of 2 C/min. from 100 C to 900 C. Desorption peaks occurred in the range of 140-480 C. There was no significant desorption at temperatures above 600 C. The amount of deuterium detected varied from a low of 8 x 1021/m2 to a high of 2.1 x 1023/m2. In one case, the amount of deuterium in a tile piece was seven times greater than the amount in a neighboring tile piece. Some of the tile pieces in the plasma-exposed region showed surface melting. Despite this, the deuterium yield from one of these pices is >1023/m2. (orig.)

  5. Thermal Induced Processes in Laminar System of Stainless Steel - Beryllium

    International Nuclear Information System (INIS)

    The paper reports on investigation of the laminar system 'stainless steel 12Cr18Ni10Ti - Be' at thermal treatment. There have been determined sequences of phase transformations along with relative amount of iron-containing phases in the samples subjected to thermal beryllization. It has been revealed that thermal beryllization of stainless steel thin foils results in γ→α transformation and formation of the beryllides NiBe and FeBe2. It has also been revealed that direct γ→α- and reverse α→γ-transformations are accompanied by, correspondingly, formation and decomposition of the beryllide NiBe. It is shown that distribution of the formed phases within sample bulk is defined by local concentration of beryllium. Based on obtained experimental data there is proposed a physical model of phase transformations in stainless steel at thermal beryllization.

  6. Optical properties and structure of beryllium lead silicate glasses

    Energy Technology Data Exchange (ETDEWEB)

    Zhidkov, I. S., E-mail: i.s.zhidkov@urfu.ru [Ural Federal University, Mira Str. 19, Yekaterinburg, 620002, Russia and Institute of Metal Physics, Russian Academy of Sciences-Ural Division, S. Kovalevskoi Str. 18, 620990 Yekaterinburg (Russian Federation); Zatsepin, A. F.; Cholakh, S. O.; Kuznetsova, Yu. A. [Ural Federal University, Mira Str. 19, Yekaterinburg, 620002 (Russian Federation)

    2014-10-21

    Luminescence and optical properties and structural features of (BeO){sub x}(PbO⋅SiO{sub 2}){sub 1−x} glasses (x = 0 ÷ 0.3) are investigated by means of optical absorption and photoluminescence spectroscopy and X-ray diffraction. The regularities of the formation of the optical absorption edge and static disorder are studied. It is shown that the optical absorption and luminescence are determined by transitions between localized states of lead ions. The impact of beryllium oxide on optical and luminescence properties and electronic structure of bands tails is discussed. The presence of two different concentration ranges with various short-range order structure and band tails nature has been established.

  7. Optical properties and structure of beryllium lead silicate glasses

    Science.gov (United States)

    Zhidkov, I. S.; Zatsepin, A. F.; Cholakh, S. O.; Kuznetsova, Yu. A.

    2014-10-01

    Luminescence and optical properties and structural features of (BeO)x(PbOṡSiO2)1-x glasses (x = 0 ÷ 0.3) are investigated by means of optical absorption and photoluminescence spectroscopy and X-ray diffraction. The regularities of the formation of the optical absorption edge and static disorder are studied. It is shown that the optical absorption and luminescence are determined by transitions between localized states of lead ions. The impact of beryllium oxide on optical and luminescence properties and electronic structure of bands tails is discussed. The presence of two different concentration ranges with various short-range order structure and band tails nature has been established.

  8. Modelling of radiation impact on ITER Beryllium wall

    International Nuclear Information System (INIS)

    In the ITER H-Mode confinement regime, edge localized instabilities (ELMs) will perturb the discharge. Plasma lost after each ELM moves along magnetic field lines and impacts on divertor armour, causing plasma contamination by back propagating eroded carbon or tungsten. These impurities produce enhanced radiation flux distributed mainly over the beryllium main chamber wall. The simulation of the complicated processes involved are subject of the integrated tokamak code TOKES that is currently under development. This work describes the new TOKES model for radiation transport through confined plasma. Equations for level populations of the multi-fluid plasma species and the propagation of different kinds of radiation (resonance, recombination and bremsstrahlung photons) are implemented. First simulation results without account of resonance lines are presented.

  9. Electron microscope observation of single - crystalline beryllium thin foils

    International Nuclear Information System (INIS)

    Thin foils prepared from single crystalline beryllium simples deformed at room temperature, have been observed by transmission electron microscopy. The various deformation modes have been investigated separately, from their early stages and their characteristic dislocation configurations have been observed. Basal slip is characterized at is outset by the presence of numerous dipoles and elongated prismatic loops. More pronounced cold work leads to the formation of dislocation tangles and bundles which eventually give a cellular structure. Prismatic slip begins by the cross-slip of dislocations from the basal plane into the prismatic plane. A cellular structure is equally observed in heavily deformed samples. Sessile dislocations have been observed in twin boundaries; they are produced by reactions between slip dislocations and twin dislocations. Finally, the study of samples quenched from 1100 deg. C and annealed at 200 deg. C has shown that the observed loops lie in prismatic planes and have a Burgers vector b 1/3. (authors)

  10. Tensile and fracture toughness test results of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Chaouadi, R.; Moons, F.; Puzzolante, J.L. [Centre d`Etude de l`Energie Nucleaire, Mol (Belgium)

    1998-01-01

    Tensile and fracture toughness test results of four Beryllium grades are reported here. The flow and fracture properties are investigated by using small size tensile and round compact tension specimens. Irradiation was performed at the BR2 material testing reactor which allows various temperature and irradiation conditions. The fast neutron fluence (>1 MeV) ranges between 0.65 and 2.45 10{sup 21} n/cm{sup 2}. In the meantime, un-irradiated specimens were aged at the irradiation temperatures to separate if any the effect of temperature from irradiation damage. Test results are analyzed and discussed, in particular in terms of the effects of material grade, test temperature, thermal ageing and neutron irradiation. (author)

  11. A systematic review of measures assessing mothers' knowledge, attitudes, confidence and satisfaction towards breastfeeding.

    Science.gov (United States)

    Chambers, Julie A; McInnes, Rhona J; Hoddinott, Pat; Alder, Elizabeth M

    2007-11-01

    In order to support breastfeeding interventions, there is a need for objective, reliable, valid and sensitive measures of factors related to breastfeeding. Publications on the development and testing of tools measuring mothers' knowledge, attitudes, confidence or self-efficiency and/or satisfaction towards breastfeeding were systematically reviewed. Twenty-two papers evaluating 13 self-report measures matched our selection criteria, and were critically appraised by two independent reviewers. All scales were tested with pregnant women or breastfeeding mothers. The 13 measures varied markedly in ease of completion and cultural appropriateness and none reached our highest level of evidence grading. Four of the measures had sufficient evidence to support their use, including the Breastfeeding Attrition Prediction Tool, the Modified Breastfeeding Evaluation Scale, the Breastfeeding Self-Efficiency Scale and the Iowa Infant Feeding Attitude Scale. There has been a tendency to develop new measures rather than evaluate the strengths and weaknesses of existing measures, particularly in different populations. PMID:18062138

  12. Cost effective aluminum beryllium mirrors for critical optics applications

    Science.gov (United States)

    Say, Carissa; Duich, Jack; Huskamp, Chris; White, Ray

    2013-09-01

    The unique performance of aluminum-beryllium frequently makes it an ideal material for manufacturing precision optical-grade metal mirrors. Traditional methods of manufacture utilize hot-pressed powder block in billet form which is subsequently machined to final dimensions. Complex component geometries such as lightweighted, non-plano mirrors require extensive tool path programming, fixturing, and CNC machining time and result in a high buy-to-fly ratio (the ratio of the mass of raw material purchased to the mass of the finished part). This increases the cost of the mirror structure as a significant percentage of the procurement cost is consumed in the form of machining, tooling, and scrap material that do not add value to the final part. Inrad Optics, Inc. and IBC Advanced Alloys Corp. undertook a joint study to evaluate the suitability of investment-cast Beralcast® 191 and 363 aluminum-beryllium as a precision mirror substrate material. Net shape investment castings of the desired geometry minimizes machining to just cleanup stock, thereby reducing the recurring procurement cost while still maintaining performance. The thermal stability of two mirrors, (one each of Beralcast® 191 and Beralcast® 363), was characterized from -40°F to +150°F. A representative pocketed mirror was developed, including the creation of a relevant geometry and production of a cast component to validate the approach. Information from the demonstration unit was used as a basis for a comparative cost study of the representative mirror produced in Beralcast® and one machined from a billet of AlBeMet® 162 (AlBeMet® is a registered trademark of Materion Corporation). The technical and financial results of these studies will be discussed in detail.

  13. Assessment of beryllium Faraday screens of the JET ICRF antennas

    International Nuclear Information System (INIS)

    The JET ICRF antennas, equipped with beryllium (Be) Faraday screens (FS), can be operated in such a way that the RF specific effects on the plasma boundary, by the impurity influx originating at the screens, are reduced to a negligible level. In dipole phasing, k parallel = 7 m-1, the influx is for all purposes negligible. In monopole phasing (kparallel = 0 m-1) the beryllium influx does not exceed ΦFSBe = 1 x 1019 atoms·MW-1·s-1 and the corresponding δZeff/PRF is -1. The observed dependences of ΦFSBe (in monopole phasing) on plasma density, antenna voltage, antenna phasing, and the angle between FS elements and the magnetic field in the boundary, B-vector(a) = B-vectorθ(a) + B-vectorT(a), confirm that the release mechanism is sputtering by ions accelerated in the RF enhanced Bohm-Debye sheaths forming at the front face of the FS. When the angle between FS and B-vector(a) is approx. 22 deg. C, the fraction of the RF power radiated by the antenna, dissipated at the screen, can reach 40%. At high antenna voltage, arcing across the FS can occur. With dipole phasing the heating efficiency is not degraded, even with the large angle, and all the power coupled by the antenna is absorbed at the resonance position near the plasma centre. The open screen design did not introduce any disadvantages. The experience from JET operation at powers of up to 22 MW shows that, if the necessary conditions are met, i.e. if RF rectification is minimized, antennas are phased as dipoles and material with low sputtering coefficients at energies of 0.5-1 keV is used, then the influx from the FS is, for all practical purposes, eliminated. (author). 19 refs, 6 figs

  14. Finite element prediction of elastic strains in beryllium compact tension specimens

    International Nuclear Information System (INIS)

    Three-dimensional finite element (FE) calculations using ABAQUS version 5.5.9 were compared to neutron diffraction measurements of a loaded, pre-cracked beryllium compact tension (CT) specimens. The objective was to validate the FE results with the experimental open-quotes elastic strainclose quotes measurements. Then the FE calculations could be used to study residual stress and other aspects of these problems in the unloaded state and the crack tip stress in the loaded state which is hard to measure experimentally. A graded FE mesh was focused on the regions containing high strain gradients, the smallest elements were approximately 0.5 mm x 0.5 mm x 0.4 mm. A standard 20-node brick element model was complemented by a model with 1/4-point elements at the crack tip. Since the neutron diffraction measurements provided a volume average of approximately a cube of edge 3.0 mm, various averaging (or integrating) techniques were used on the FE results. Several integration schemes showed good agreement with the experimental results

  15. REMOVAL OF BERYLLIUM FROM DRINKING WATER BY CHEMICAL COAGULATION AND LIME SOFTENING

    Science.gov (United States)

    The effectiveness of conventional drinking water treatment and lime softening was evaluated for beryllium removal from two drinking water sources. ar test studies were conducted to determine how common coagulants (aluminum sulfate and ferric chloride and lime softening performed ...

  16. Estimations of neutron yield from beryllium target irradiated by SPring-8 hard synchrotron radiation

    CERN Document Server

    Gryaznykh, D A; Plokhoi, V V

    2000-01-01

    The possibility of creating a neutron source based on ''SPring-8'' synchrotron radiation interaction with beryllium targets is discussed. The possible neutron yield is estimated to be of order 10 sup 1 sup 2 s sup - sup 1 .

  17. Neutron field produced by 25 MeV deuteron on thick beryllium for radiobiological study; energy spectrum.

    Science.gov (United States)

    Takada, Masashi; Mihara, Erika; Sasaki, Michiya; Nakamura, Takashi; Honma, Toshihiko; Kono, Koji; Fujitaka, Kazunobu

    2004-01-01

    Biological data is necessary for estimation of protection from neutrons, but there is a lack of data on biological effects of neutrons for radiation protection. Radiological study on fast neutrons has been done at the National Institute of Radiological Sciences. An intense neutron source has been produced by 25 MeV deuterons on a thick beryllium target. The neutron energy spectrum, which is essential for neutron energy deposition calculation, was measured from thermal to maximum energy range by using an organic liquid scintillator and multi-sphere moderated 3He proportional counters. The spectrum of the gamma rays accompanying the neutron beam was measured simultaneously with the neutron spectrum using the organic liquid scintillator. The transmission by the shield of the spurious neutrons originating from the target was measured to be less than 1% by using the organic liquid scintillator placed behind the collimator. The measured neutron energy spectrum is useful in dose calculations for radiobiology studies.

  18. Self-Report Measures of Boredom: An Updated Review of the Literature.

    Science.gov (United States)

    Vodanovich, Stephen J; Watt, John D

    2016-01-01

    A detailed review of the psychometric measures of boredom was published approximately 12 years ago (Vodanovich, 2003). Since that time, numerous studies have been conducted on existing scales, and new measures of boredom have been developed. Given these assessment advancements, an updated review of self-report boredom scales is warranted. The primary focus of the current review is research published since 2003, and it includes a total of 16 boredom scales. The measures reviewed consist of two trait assessments (Boredom Proneness Scale, Boredom Susceptibility subscale of the Sensation Seeking Scale), five context-specific trait boredom scales (Boredom Coping Scale, Leisure Boredom Scale, Free Time Boredom Scale, Sexual Boredom Scale, Relational Boredom Scale), three assessments of state boredom (Multidimensional State Boredom Scale, State Boredom Measure, Boredom Experience Scale), and six context-specific state boredom measures-Lee's Job Boredom Scale, Dutch Boredom Scale, Boredom Coping Scale (Academic), the Boredom subscale of the Achievement Emotions Questionnaire, Academic Boredom Scale, Precursors to Boredom Scale. In addition to providing a review of these measures, a brief critique of each scale is included, as well as suggestions for needed research focus. PMID:26646053

  19. A Review of Acculturation Measures and Their Utility in Studies Promoting Latino Health

    Science.gov (United States)

    Wallace, Phyllis M.; Pomery, Elizabeth A.; Latimer, Amy E.; Martinez, Josefa L.; Salovey, Peter

    2010-01-01

    The authors reviewed the acculturation literature with the goal of identifying measures used to assess acculturation in Hispanic populations in the context of studies of health knowledge, attitudes, and behavior change. Twenty-six acculturation measures were identified and summarized. As the Hispanic population continues to grow in the United…

  20. Self-Report Measures of Parent-Adolescent Attachment and Separation-Individuation: A Selective Review.

    Science.gov (United States)

    Lopez, Frederick G.; Gover, Mark R.

    1993-01-01

    Reviews and critiques three self-report measures of parent-adolescent attachment (Parental Bonding Instrument, Parental Attachment Questionnaire, Inventory of Parent and Peer Attachment) and three self-report measures of parent-adolescent separation-individuation (Psychological Separation Inventory, Personal Authority in the Family System…

  1. Measures of Self-Care Independence for Children with Osteochondrodysplasia: A Clinimetric Review

    Science.gov (United States)

    Ireland, Penelope; Johnston, Leanne M.

    2012-01-01

    This systematic review evaluates the validity, reliability, and clinical utility of outcome measures used to assess self-care skills among children with congenital musculoskeletal conditions and assesses the applicability of these measures for children with osteochondrodysplasia aged 0-12 years. Electronic databases were searched to identify…

  2. A Systematic Review of Psychometric Evaluation of Motivational Interviewing Integrity Measures

    Science.gov (United States)

    Wallace, Lloyd; Turner, Fiona

    2009-01-01

    The Motivational Interviewing Skills Code (MISC) has been developed to measure motivational interviewing skill, but a need has been identified for more economical instruments. This study expands on a previous systematic review by Madson and Campbell (2006) and examines the extent to which motivational interviewing integrity measures other than the…

  3. A Critical Review of Theories and Measures of Ethics-Related Leadership.

    Science.gov (United States)

    Zhu, Weichun; Zheng, Xiaoming; Riggio, Ronald E; Zhang, Xi

    2015-01-01

    This chapter reviews the different theoretical perspectives and measurements of ethics-related leadership models, including ethical leadership, transformational leadership, authentic leadership, servant leadership, spiritual leadership, and a virtues-based approach to leadership ethics. The similarities and differences among these theoretical models and measures to ethics-related leadership are discussed.

  4. Measurement of Habitual Physical Activity Performance in Adolescents with Cerebral Palsy: A Systematic Review

    Science.gov (United States)

    Clanchy, Kelly M.; Tweedy, Sean M.; Boyd, Roslyn

    2011-01-01

    Aim: This systematic review compares the validity, reliability, and clinical use of habitual physical activity (HPA) performance measures in adolescents with cerebral palsy (CP). Method: Measures of HPA across Gross Motor Function Classification System (GMFCS) levels I-V for adolescents (10-18y) with CP were included if at least 60% of items…

  5. A Critical Review of Theories and Measures of Ethics-Related Leadership.

    Science.gov (United States)

    Zhu, Weichun; Zheng, Xiaoming; Riggio, Ronald E; Zhang, Xi

    2015-01-01

    This chapter reviews the different theoretical perspectives and measurements of ethics-related leadership models, including ethical leadership, transformational leadership, authentic leadership, servant leadership, spiritual leadership, and a virtues-based approach to leadership ethics. The similarities and differences among these theoretical models and measures to ethics-related leadership are discussed. PMID:26894906

  6. Measuring patient knowledge of asthma: a systematic review of outcome measures.

    NARCIS (Netherlands)

    Pink, J.; Pink, K.; Elwyn, G.

    2009-01-01

    BACKGROUND: Asthma self-management education is a key component of international guidelines. No gold standard patient centred outcome measure exists for asthma knowledge. Our aim was to identify high-quality, validated, and reliable outcome measures suitable for use in either the research or clinica

  7. Measurement of stiffness of standing trees and felled logs using acoustics: A review.

    Science.gov (United States)

    Legg, Mathew; Bradley, Stuart

    2016-02-01

    This paper provides a review on the use of acoustics to measure stiffness of standing trees, stems, and logs. An outline is given of the properties of wood and how these are related to stiffness and acoustic velocity throughout the tree. Factors are described that influence the speed of sound in wood, including the different types of acoustic waves which propagate in tree stems and lumber. Acoustic tools and techniques that have been used to measure the stiffness of wood are reviewed. The reasons for a systematic difference between direct and acoustic measurements of stiffness for standing trees, and methods for correction, are discussed. Other techniques, which have been used in addition to acoustics to try to improve stiffness measurements, are also briefly described. Also reviewed are studies which have used acoustic tools to investigate factors that influence the stiffness of trees. These factors include different silvicultural practices, geographic and environmental conditions, and genetics.

  8. Disability measurement for lymphatic filariasis: a review of generic tools used within morbidity management programs.

    Directory of Open Access Journals (Sweden)

    Lynne Zeldenryk

    Full Text Available Lymphatic filariasis (LF-related disability affects 40 million people globally, making LF the leading cause of physical disability in the world. Despite this, there is limited research into how the impacts of LF-related disability are best measured. This article identifies the tools currently being used to measure LF-related disability and reviews their applicability against the known impacts of LF. The findings from the review show that the generic disability tools currently used by LF programs fail to measure the majority of known impacts of LF-related disability. The findings from the review support the development of an LF-specific disability measurement tool and raise doubt about the suitability of generic disability tools to assess disability related to neglected tropical diseases (NTDs globally.

  9. Characterization of phagolysosomal simulant fluid for study of beryllium aerosol particle dissolution.

    Science.gov (United States)

    Stefaniak, A B; Guilmette, R A; Day, G A; Hoover, M D; Breysse, P N; Scripsick, R C

    2005-02-01

    A simulant of phagolysosomal fluid is needed for beryllium particle dissolution research because intraphagolysosomal dissolution is believed to be a necessary step in the cellular immune response associated with development of chronic beryllium disease. Thus, we refined and characterized a potassium hydrogen phthalate (KHP) buffered solution with pH 4.55, termed phagolysosomal simulant fluid (PSF), for use in a static dissolution technique. To characterize the simulant, beryllium dissolution in PSF was compared to dissolution in the J774A.1 murine cell line. The effects of ionic composition, buffer strength, and the presence of the antifungal agent alkylbenzyldimethylammonium chloride (ABDC) on beryllium dissolution in PSF were evaluated. Beryllium dissolution in PSF was not different from dissolution in the J774A.1 murine cell line (p = 0.78) or from dissolution in another simulant having the same pH but different ionic composition (p = 0.73). A buffer concentration of 0.01-M KHP did not appear adequate to maintain pH under all conditions. There was no difference between dissolution in PSF with 0.01-M KHP and 0.02-M KHP (p = 0.12). At 0.04-M KHP, beryllium dissolution was increased relative to 0.02-M KHP (p = 0.02). Use of a 0.02-M KHP buffer concentration in the standard formulation for PSF provided stability in pH without alteration of the dissolution rate. The presence of ABDC did not influence beryllium dissolution in PSF (p = 0.35). PSF appears to be a useful and appropriate model of in vitro beryllium dissolution when using a static dissolution technique. In addition, the critical approach used to evaluate and adjust the composition of PSF may serve as a framework for characterizing PSF to study dissolution of other metal and oxide particles.

  10. Impact of beryllium reflector ageing on Safari–1 reactor core parameters / L.E. Moloko

    OpenAIRE

    Moloko, Lesego Ernest

    2011-01-01

    The build–up of 6Li and 3He, that is, the strong thermal neutron absorbers or the so called "neutron poisons", in the beryllium reflector changes the physical characteristics of the reactor, such as reactivity, neutron spectra, neutron flux level, power distribution, etc.; furthermore,gaseous isotopes such as 3H and 4He induce swelling and embrittlement of the reflector. The SAFARI–1 research reactor, operated by Necsa at Pelindaba in South Africa, uses a beryllium reflector on...

  11. The Status of Beryllium Research for Fusion in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Glen R. Longhurst

    2003-12-01

    Use of beryllium in fusion reactors has been considered for neutron multiplication in breeding blankets and as an oxygen getter for plasma-facing surfaces. Previous beryllium research for fusion in the United States included issues of interest to fission (swelling and changes in mechanical and thermal properties) as well as interactions with plasmas and hydrogen isotopes and methods of fabrication. When the United States formally withdrew its participation in the International Thermonuclear Experimental Reactor (ITER) program, much of this effort was terminated. The focus in the U.S. has been mainly on toxic effects of beryllium and on industrial hygiene and health-related issues. Work continued at the INEEL and elsewhere on beryllium-containing molten salts. This activity is part of the JUPITER II Agreement. Plasma spray of ITER first wall samples at Los Alamos National Laboratory has been performed under the European Fusion Development Agreement. Effects of irradiation on beryllium structure are being studied at Oak Ridge National Laboratory. Numerical and phenomenological models are being developed and applied to better understand important processes and to assist with design. Presently, studies are underway at the University of California Los Angeles to investigate thermo-mechanical characteristics of beryllium pebble beds, similar to research being carried out at Forschungszentrum Karlsruhe and elsewhere. Additional work, not funded by the fusion program, has dealt with issues of disposal, and recycling.

  12. Sensitive detection of beryllium using a fiber optic liquid waveguide cell.

    Science.gov (United States)

    Deng, Gang; Wei, Lily; Collins, Greg E

    2003-05-28

    The metallochromic chelating agent, Chromazurol S, has been utilized in conjunction with a fiber optic liquid waveguide capillary cell to enable the sensitive detection of beryllium in solution (30 ng l(-1) detection limit) and following extraction from a contaminated plexiglas surface (0.5 ng cm(-2) detection limit). The addition of a cationic surfactant, cetylpyridinium chloride, to Chromazurol S at pH 10 in Tris-HCl buffer results in the formation of two bathochromic peaks in the visible spectrum following metal chelation by beryllium. The first absorbance band, at 515 nm, is intermediate in nature, permitting maximal sensitivity for low beryllium concentrations, but diminishing in intensity at concentrations above 100 mug l(-1). The second absorbance band, centered at 610 nm, dominates for beryllium concentrations of 100 mug l(-1) and above. Experimental conditions including pH, buffer type, additive surfactants, masking agents, and dye concentration were investigated in order to optimize detection sensitivity and selectivity. A fiber optic spectrometer is used with both a liquid waveguide capillary cell and 1 cm cuvette cell, to give a sensitive and broad dynamic range for beryllium detection that capitalizes on both beryllium metal chelate absorbance bands formed under these conditions.

  13. Preconcentration and separation of ultra-trace beryllium using quinalizarine-modified magnetic microparticles

    Energy Technology Data Exchange (ETDEWEB)

    Ashtari, Parviz, E-mail: pashtari@aeoi.org.ir [State Key Laboratory of Chemo/Biosensing and Chemometrics, Biomedical Engineering Center, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); NFCS, Nuclear Science and Technology Research Institute, PO Box 11365-8486, Tehran (Iran, Islamic Republic of); Wang Kemin; Yang Xiaohai [State Key Laboratory of Chemo/Biosensing and Chemometrics, Biomedical Engineering Center, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Ahmadi, Seyed Javad [NFCS, Nuclear Science and Technology Research Institute, PO Box 11365-8486, Tehran (Iran, Islamic Republic of)

    2009-07-30

    Magnetically-assisted chemical separation/preconcentration method for the analysis of beryllium from aqueous solutions was developed. According to this method several extractants were coated on certain magnetic microparticles to assist the extraction of beryllium from the aqueous solutions. The influence of different parameters (type and amount of extractant, pH, equilibrium time and ionic strength) was investigated. Also, the interfering effect of various cationic and anionic species on the percent recovery of beryllium was studied. The applied spectrophotometric method showed good linearity and precision at a given wavelength (605.0 nm). Among the extractants used, quinalizarine resulted in almost a full recovery of beryllium at pH 7.4, which was the optimum extraction pH. The equilibrium time of the extraction was 10.0 min. The quantitative re-extraction was carried out by 0.5 M nitric acid. Also, the stability of the extractant-coated magnetic microparticles was 4 cycles (extraction and re-extraction) and the used magnetic microparticles showed good selectivity for beryllium against other cations and anions. Finally, the developed method was applicable for the preconcentration and separation of beryllium from spring water, tap water and certified reference waters. The obtained detection limit was 30 ng L{sup -1}.

  14. Low-temperature low-dose neutron irradiation effects on Brush Wellman S65-C and Kawechi Berylco P0 beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Snead, L.L. [Oak Ridge National Lab., TN (United States)

    1998-09-01

    The mechanical property results for two high quality beryllium materials subjected to low temperature, low dose neutron irradiation in water moderated reactors are presented. Materials chosen were the S65-C ITER candidate material produced by Brush Wellman, and Kawecki Berylco Industries P0 beryllium. Both materials were processed by vacuum hot pressing. Mini sheet tensile and thermal diffusivity specimens were irradiated in the temperature range of {approximately}100--275 C from a fast (E > 0.1 MeV) neutron dose of 0.05 to 1.0 {times} 10{sup 25} n/m{sup 2} in the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory and the High Flux Beam Reactor (HFBR) at the Brookhaven National Laboratory. As expected from earlier work on beryllium, both materials underwent significant embrittlement with corresponding reduction in ductility and increased strength. Both thermal diffusivity and volumetric expansion were measured and found to be negligible in this temperature and fluence range. Of significance from this work is that while both materials rapidly embrittle at these ITER relevant irradiation conditions, some ductility (>1--2%) remains, which contrasts with a body of earlier work including recent work on the Brush-Wellman S65-C material irradiated to slightly higher neutron fluence.

  15. The applicability of home blood pressure measurement in clinical practice: A review of literature

    OpenAIRE

    Verberk, Willem J; Kroon, Abraham A.; Jongen-Vancraybex, Heidi A; Peter W de Leeuw

    2007-01-01

    Purpose To review the literature on home blood pressure measurement (HBPM), to examine its validity and applicability for clinical practice and to provide recommendations regarding HBPM assessment. Findings HBPM can eliminate the white coat effect and offers the possibility to obtain multiple measurements under standardized conditions, which increases knowledge of overall blood pressure value. Although it is not entirely capable of replacing ambulatory blood pressure measurement (ABPM), HBPM ...

  16. Optimized beryllium target design for indirectly driven inertial confinement fusion experiments on the National Ignition Facility

    Science.gov (United States)

    Simakov, Andrei N.; Wilson, Douglas C.; Yi, Sunghwan A.; Kline, John L.; Clark, Daniel S.; Milovich, Jose L.; Salmonson, Jay D.; Batha, Steven H.

    2014-02-01

    For indirect drive inertial confinement fusion, Beryllium (Be) ablators offer a number of important advantages as compared with other ablator materials, e.g., plastic and high density carbon. In particular, the low opacity and relatively high density of Be lead to higher rocket efficiencies giving a higher fuel implosion velocity for a given X-ray drive; and to higher ablation velocities providing more ablative stabilization and reducing the effect of hydrodynamic instabilities on the implosion performance. Be ablator advantages provide a larger target design optimization space and can significantly improve the National Ignition Facility (NIF) [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)] ignition margin. Herein, we summarize the Be advantages, briefly review NIF Be target history, and present a modern, optimized, low adiabat, Revision 6 NIF Be target design. This design takes advantage of knowledge gained from recent NIF experiments, including more realistic levels of laser-plasma energy backscatter, degraded hohlraum-capsule coupling, and the presence of cross-beam energy transfer.

  17. The Measurement of Maximal (Anaerobic) Power Output on a Cycle Ergometer: A Critical Review

    OpenAIRE

    Tarak Driss; Henry Vandewalle

    2013-01-01

    The interests and limits of the different methods and protocols of maximal (anaerobic) power (P max) assessment are reviewed: single all-out tests versus force-velocity tests, isokinetic ergometers versus friction-loaded ergometers, measure of P max during the acceleration phase or at peak velocity. The effects of training, athletic practice, diet and pharmacological substances upon the production of maximal mechanical power are not discussed in this review mainly focused on the technical (er...

  18. Measurement and Segmentation of College Students' Noncognitive Attributes: A Targeted Review

    OpenAIRE

    Ann E. Person; Scott E. Baumgartner; Kristin Hallgren; Betsy Santos

    2014-01-01

    This report presents findings from a targeted document review and expert interviews conducted as part of the Student Segmentation Initiative, which was funded by the Bill & Melinda Gates Foundation’s Postsecondary Success strategy. The review addresses three questions relevant to the initiative: (1) What instruments and measures are available to assess postsecondary students’ noncognitive attributes? (2) To what extent are these instruments used to classify or segment student populations?...

  19. Structural analysis of a 50-cm-diameter open-back triangular cell beryllium mirror in a cryogenic environment

    Science.gov (United States)

    Craig, Lawrence D.; Cline, Todd; Hadaway, James B.; Nein, Max E.; Smithers, Martin E.; Keidel, John W.; Stahl, H. Philip

    2001-11-01

    This paper discusses NASTRAN finite element analysis of the Sub-scale Beryllium Mirror Demonstrator (SBMD), which has been developed by Ball Aerospace as an experimental lightweight (9.76 kg/m2 areal density) design concept for the Next Generation Space Telescope (NGST). The mirror was repeatedly subjected to a 30 K environment in the large cryogenic test chamber at Marshall Space Flight Center (MSFC). Deformations on the mirror surface were measured optically. The surface distortions predicted by NASTRAN were analyzed for comparison with the measured values. Model results compared more favorably with measured results for the ambient temperature cases. For the cryogenic cases, the influence of geometry and material property variations was investigated to obtain closer correlation.

  20. Review of geochemical measurement techniques for a nuclear waste repository in bedded salt

    International Nuclear Information System (INIS)

    A broad, general review is presented of geochemical measurement techniques that can provide data necessary for site selection and repository effectiveness assessment for a radioactive waste repository in bedded salt. The available measurement techniques are organized according to the parameter measured. The list of geochemical parameters include all those measurable geochemical properties of a sample whole values determine the geochemical characteristics or behavior of the system. For each technique, remarks are made pertaining to the operating principles of the measurement instrument and the purpose for which the technique is used. Attention is drawn to areas where further research and development are needed

  1. Tritium release of Li4SiO4, Li2O and beryllium and chemical compatibility of beryllium with Li4SiO4, Li2O and steel (SIBELIUS irradiation)

    International Nuclear Information System (INIS)

    The objective of the SIBELIUS irradiation, a joint EC-US project performed at CEN Grenoble, was to investigate the oxidation kinetics of beryllium in contact with ceramic and the nature and extent of beryllium in contact with ceramic and the nature and extent of beryllium interaction with (316 L and 1.4914) steel in a neutron environment. In this work post irradiation examinations of SIBELIUS specimens performed at KfK are described. Tritium release of Li4SiO4, Li2O and beryllium was studied by out-of-pile annealing and chemical compatibility of beryllium with Li4SiO4, Li2O and steel by microscopic examinations. Tritium release of the ceramics was found to be consistent with SIBELIUS inpile observations and previous tests. Release of tritium generated in beryllium was found to be very slow, in accordance with previous work. For beryllium which was in contact with ceramic during irradiation, a second type of tritium, caused by injection of 2.7 MeV tritons generated in the ceramic, is observed. Release of injected tritium is faster than that of generated. Evidence for injected tritium in beryllium was also found in the microscopic studies. The observed minor chemical reactions of beryllium with steel and probably also those with breeder materials under neutron irradiation are consistent with the results of laboratory annealing tests. (orig.)

  2. Southeast Alaska Acoustic Measurement Facility (SEAFAC) environmental data base review, evaluation, and upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Strand, J.A.; Skalski, J.R.; Faulkner, L.L.; Rodman, C.W.; Carlile, D.W.; Ecker, R.M.; Nicholls, A.K.; Ramsdell, J.V.; Scott, M.J.

    1986-04-01

    This report summarizes the principal issues of public concern, the adequacy of the environmental data base to answer the issues of concern, and the additional data collection required to support a National Environmental Policy Act (NEPA) review of the proposed Southeast Alaska Acoustic Measurement Facility (SEAFAC). The report is based on a review of the readily available environmental literature and a site visit. Representatives of local, state, and federal agencies were also interviewed for their personal insights and concerns not discovered during the literature review.

  3. Measuring and reporting quality of life outcomes in clinical trials in cystic fibrosis: a critical review

    Directory of Open Access Journals (Sweden)

    Hart Anna

    2005-03-01

    Full Text Available Abstract Good quality clinical trials are essential to inform the best cystic fibrosis (CF management and care, by determining and comparing the effectiveness of new and existing therapies and drug delivery systems. The formal inclusion of quality of life (QoL as an outcome measure in CF clinical trials is becoming more common. Both an appropriate QoL measure and sound methodology are required in order to draw valid inferences about treatments and QoL. A review was undertaken of randomised controlled trials in cystic fibrosis where QoL was measured. EMBASE, MEDLINE and ISI Web of Science were searched to locate all full papers in the English language reporting randomised controlled trials in cystic fibrosis, published between January 1991 and December 2004. All Cochrane reviews published before December 2004 were hand searched. Papers were included if the authors had reported that they had measured QoL or well being in the trial. 16 trials were identified. The interventions investigated were: antibiotics (4; home versus hospital administration of antibiotics (1; steroids (1; mucolytic therapies (6; exercise (3 and pancreatic enzymes (1. Not one trial evaluated in this review provided conclusive results concerning QoL. This review highlights many of the pitfalls of QoL measurement in CF clinical trials and provides constructive information concerning the design and reporting of trials measuring QoL.

  4. Characteristics of microstructure and tritium release properties of different kinds of beryllium pebbles for application in tritium breeding modules

    Energy Technology Data Exchange (ETDEWEB)

    Kurinskiy, P.; Vladimirov, P.; Moeslang, A. [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany). Inst. for Applied Materials - Applied Materials Physics (IAM-AWP); Rolli, R. [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany). Inst. for Applied Materials - Materials Biomechanics (IAM-WBM); Zmitko, M. [The European Joint Undertaking for ITER and the Development of Fusion Energy, Barcelona (Spain)

    2013-07-01

    Beryllium pebbles with diameters of 1 mm are considered to be perspective material for the use as neutron multiplier in tritium breeding modules of fusion reactors. Up to now, the main concept of helium-cooled breeding blanket in ITER project foresees the use of 1 mm beryllium pebbles fabricated by company NGK, Japan. It is notable that beryllium pebbles of other types are commercially available at the market. Presented work is dedicated to a study of characteristics of microstructure, packaging density and parameters of tritium release of beryllium pebbles produced by Bochvar Institute, Russian Federation, and Company Materion, USA. (orig.).

  5. Derivation of beryllium guidelines for use in establishing cleanup levels at the Peek Street and Sacandaga sites, New York

    International Nuclear Information System (INIS)

    Guideline levels are derived for beryllium in soil and on indoor surfaces at the Peek Street and Sacandaga sites in the state of New York. On the basis of highly conservative assumptions, the soil beryllium concentration that corresponds to a 10-4 carcinogenic risk level is estimated to be 13 mg/kg at both sites. Calculations indicate that the proposed US Department of Energy guideline of 2 μg/ft2 for beryllium in dust on indoor surfaces would be sufficiently protective of human health. For occupational protection of workers during cleanup operations, Office of Safety and Health Administration standards for beryllium are referenced and restated

  6. Performance measures of the specialty referral process: a systematic review of the literature

    Directory of Open Access Journals (Sweden)

    Guevara James P

    2011-07-01

    Full Text Available Abstract Background Performance of specialty referrals is coming under scrutiny, but a lack of identifiable measures impedes measurement efforts. The objective of this study was to systematically review the literature to identify published measures that assess specialty referrals. Methods We performed a systematic review of the literature for measures of specialty referral. Searches were made of MEDLINE and HealthSTAR databases, references of eligible papers, and citations provided by content experts. Measures were eligible if they were published from January 1973 to June 2009, reported on validity and/or reliability of the measure, and were applicable to Organization for Economic Cooperation and Development healthcare systems. We classified measures according to a conceptual framework, which underwent content validation with an expert panel. Results We identified 2,964 potentially eligible papers. After abstract and full-text review, we selected 214 papers containing 244 measures. Most measures were applied in adults (57%, assessed structural elements of the referral process (60%, and collected data via survey (62%. Measures were classified into non-mutually exclusive domains: need for specialty care (N = 14, referral initiation (N = 73, entry into specialty care (N = 53, coordination (N = 60, referral type (N = 3, clinical tasks (N = 19, resource use (N = 13, quality (N = 57, and outcomes (N = 9. Conclusions Published measures are available to assess the specialty referral process, although some domains are limited. Because many of these measures have been not been extensively validated in general populations, assess limited aspects of the referral process, and require new data collection, their applicability and preference in assessment of the specialty referral process is needed.

  7. Functional Status Assessment of Patients With COPD: A Systematic Review of Performance-Based Measures and Patient-Reported Measures.

    Science.gov (United States)

    Liu, Yang; Li, Honghe; Ding, Ning; Wang, Ningning; Wen, Deliang

    2016-05-01

    Presently, there is no recommendation on how to assess functional status of chronic obstructive pulmonary disease (COPD) patients. This study aimed to summarize and systematically evaluate these measures.Studies on measures of COPD patients' functional status published before the end of January 2015 were included using a search filters in PubMed and Web of Science, screening reference lists of all included studies, and cross-checking against some relevant reviews. After title, abstract, and main text screening, the remaining was appraised using the Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN) 4-point checklist. All measures from these studies were rated according to best-evidence synthesis and the best-rated measures were selected.A total of 6447 records were found and 102 studies were reviewed, suggesting 44 performance-based measures and 14 patient-reported measures. The majority of the studies focused on internal consistency, reliability, and hypothesis testing, but only 21% of them employed good or excellent methodology. Their common weaknesses include lack of checks for unidimensionality, inadequate sample sizes, no prior hypotheses, and improper methods. On average, patient-reported measures perform better than performance-based measures. The best-rated patient-reported measures are functional performance inventory (FPI), functional performance inventory short form (FPI-SF), living with COPD questionnaire (LCOPD), COPD activity rating scale (CARS), University of Cincinnati dyspnea questionnaire (UCDQ), shortness of breath with daily activities (SOBDA), and short-form pulmonary functional status scale (PFSS-11), and the best-rated performance-based measures are exercise testing: 6-minute walk test (6MWT), endurance treadmill test, and usual 4-meter gait speed (usual 4MGS).Further research is needed to evaluate the reliability and validity of performance-based measures since present studies failed to provide convincing

  8. A systematic review of instruments that measure attitudes toward homosexual men.

    Science.gov (United States)

    Grey, Jeremy A; Robinson, Beatrice Bean E; Coleman, Eli; Bockting, Walter O

    2013-01-01

    Scientific interest in the measurement of homophobia and internalized homophobia has grown over the past 30 years, and new instruments and terms have emerged. To help researchers with the challenging task of identifying appropriate measures for studies in sexual-minority health, we reviewed measures of homophobia published in the academic literature from 1970 to 2012. Instruments that measured attitudes toward male homosexuals/homosexuality or measured homosexuals' internalized attitudes toward homosexuality were identified using measurement manuals and a systematic review. A total of 23 instruments met criteria for inclusion, and their features were summarized and compared. All 23 instruments met minimal criteria for adequate scale construction, including scale development, sampling, reliability, and evidence of validity. Validity evidence was diverse and was categorized as interaction with gay men, HIV/AIDS variables, mental health, and conservative religious or political beliefs. Homophobia was additionally correlated with authoritarianism and bias, gender ideology, gender differences, and reactions to homosexual stimuli. Internalized homophobia was validated by examining relationships with disclosing one's homosexuality and level of homosexual identity development. We hope this review will make the process of instrument selection more efficient by allowing researchers to easily locate, evaluate, and choose the proper measure based on their research question and population of interest.

  9. Monitoring beryllium during site cleanup and closure using a real-time analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Schlager, R.J.; Sappey, A.D.; French, P.D. [ADA Technologies, Inc., Englewood, CO (United States)

    1998-12-31

    Beryllium metal has a number of unique properties that have been exploited for use in commercial and government applications. Airborne beryllium particles can represent a significant human health hazard if deposited in the lungs. These particles can cause immunologically-mediated chronic granulomatous lung disease (chronic beryllium disease). Traditional methods of monitoring airborne beryllium involve collecting samples of air within the work area using a filter. The filter then undergoes chemical analysis to determine the amount of beryllium collected during the sampling period. These methods are time-consuming and results are known only after a potential exposure has occurred. The need for monitoring exposures in real time has prompted government and commercial companies to develop instrumentation that will allow for the real time assessment of short-term exposures so that adequate protection for workers in contaminated environments can be provided. Such an analyzer provides a tool that will allow government and commercial sites to be cleaned up in a more safe and effective manner since exposure assessments can be made instantaneously. This paper describes the development and initial testing of an analyzer for monitoring airborne beryllium using a technique known as Laser-Induced Breakdown Spectroscopy (LIBS). Energy from a focused, pulsed laser is used to vaporize a sample and create an intense plasma. The light emitted from the plasma is analyzed to determine the quantity of beryllium in the sampled air. A commercial prototype analyzer has been fabricated and tested in a program conducted by Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Lovelace Respiratory Research Institute, and ADA Technologies, Inc. Design features of the analyzer and preliminary test results are presented.

  10. In-pile thermocycling testing and post-test analysis of beryllium divertor mockups

    Energy Technology Data Exchange (ETDEWEB)

    Giniatulin, R.; Mazul, I. [Efremov Inst., St. Petersburg (Russian Federation); Melder, R.; Pokrovsky, A.; Sandakov, V.; Shiuchkin, A.

    1998-01-01

    The main damaging factors which impact the ITER divertor components are neutron irradiation, cyclic surface heat loads and hydrogen environment. One of the important questions in divertor mockups development is the reliability of beryllium/copper joints and the beryllium resistance under neutron irradiation and thermal cycling. This work presents the experiment, where neutron irradiation and thermocyclic heat loads were applied simultaneously for two beryllium/copper divertor mockups in a nuclear reactor channel to simulate divertor operational conditions. Two mockups with different beryllium grades were mounted facing each other with the tantalum heater placed between them. This device was installed in the active zone of the nuclear reactor SM-2 (Dimitrovgrad, Russia) and the tantalum block was heated by neutron irradiation up to a high temperature. The main part of the heat flux from the tantalum surface was transported to the beryllium surface through hydrogen, as a result the heat flux loaded two mockups simultaneously. The mockups were cooled by reactor water. The device was lowered to the active zone so as to obtain the heating regime and to provide cooling lifted. This experiment was performed under the following conditions: tantalum heater temperature - 1950degC; hydrogen environment -1000 Pa; surface heat flux density -3.2 MW/m{sup 2}; number of thermal cycles (lowering and lifting) -101; load time in each cycle - 200-5000 s; dwell time (no heat flux, no neutrons) - 300-2000 s; cooling water parameters: v - 1 m/s, Tin - 50degC, Pin - 5 MPa; neutron fluence -2.5 x 10{sup 20} cm{sup -2} ({approx}8 years of ITER divertor operation from the start up). The metallographic analysis was performed after experiment to investigate the beryllium and beryllium/copper joint structures, the results are presented in the paper. (author)

  11. A Comparison of "Total Dust" and Inhalable Personal Sampling for Beryllium Exposure

    Energy Technology Data Exchange (ETDEWEB)

    Carter, Colleen M. [Tulane Univ., New Orleans, LA (United States). School of Public Health and Tropical Medicine

    2012-05-09

    In 2009, the American Conference of Governmental Industrial Hygienists (ACGIH) reduced the Beryllium (Be) 8-hr Time Weighted Average Threshold Limit Value (TLV-TWA) from 2.0 μg/m3 to 0.05 μg/m3 with an inhalable 'I' designation in accordance with ACGIH's particle size-selective criterion for inhalable mass. Currently, per the Department of Energy (DOE) requirements, the Lawrence Livermore National Laboratory (LLNL) is following the Occupational Health and Safety Administration (OSHA) Permissible Exposure Limit (PEL) of 2.0 μg/m3 as an 8-hr TWA, which is also the 2005 ACGIH TLV-TWA, and an Action Level (AL) of 0.2 μg/m3 and sampling is performed using the 37mm (total dust) sampling method. Since DOE is considering adopting the newer 2009 TLV guidelines, the goal of this study was to determine if the current method of sampling using the 37mm (total dust) sampler would produce results that are comparable to what would be measured using the IOM (inhalable) sampler specific to the application of high energy explosive work at LLNL's remote experimental test facility at Site 300. Side-by-side personal sampling using the two samplers was performed over an approximately two-week period during chamber re-entry and cleanup procedures following detonation of an explosive assembly containing Beryllium (Be). The average ratio of personal sampling results for the IOM (inhalable) vs. 37-mm (total dust) sampler was 1.1:1 with a P-value of 0.62, indicating that there was no statistically significant difference in the performance of the two samplers. Therefore, for the type of activity monitored during this study, the 37-mm sampling cassette would be considered a suitable alternative to the IOM sampler for collecting inhalable particulate matter, which is important given the many practical and economic advantages that it presents. However, similar comparison studies would be necessary for this conclusion to be

  12. Sub-micro level monitoring of beryllium ions with a novel beryllium sensor based on 2,6-diphenyl-4-benzo-9-crown-3-pyridine.

    Science.gov (United States)

    Ganjali, Mohammad Reza; Rahimi-Nasrabadi, Mehdi; Maddah, Bozorgmehr; Moghimi, Abolghasem; Faal-Rastegar, Madjid; Borhany, Shahin; Namazian, Mansour

    2004-07-01

    The 2,6-diphenyl-4-benzo-9-crown-3-pyridine (DPCP) was used as an excellent ionophore in construction of a coated graphite poly(vinyl chloride) (PVC)-based membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 60% o-nitrophenyloctyl ether (NPOE), 5% 2,6-diphenyl-4-benzo-9-crown-3-pyridine and 5% sodium tetraphenyl borate (TBP). This sensor shows very good selectivity and sensitivity towards beryllium ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The sensor revealed a great enhancement in selectivity coefficients and sensitivity for beryllium, in comparison with the previously reported beryllium electrodes. The electrode exhibits a Nernstian behavior (with slope of 29.6mV per decade) over a very wide concentration range (1.0x10(-7) to 1.0x10(-1)) with a detection limit of 4.0x10(-8)M (360pgml(-1)). It shows relatively fast response time, in whole concentration range (beryllium in mineral ore.

  13. Conceptualization and measurement of homosexuality in sex surveys: a critical review

    OpenAIRE

    Michaels Stuart; Lhomond Brigitte

    2006-01-01

    This article reviews major national population sex surveys that have asked questions about homosexuality focusing on conceptual and methodological issues, including the definitions of sex, the measured aspects of homosexuality, sampling and interviewing technique, and questionnaire design. Reported rates of major measures of same-sex attraction, behavior, partners, and sexual identity from surveys are also presented and compared. The study of homosexuality in surveys has been shaped by the re...

  14. Turbidimeter Design and Analysis: A Review on Optical Fiber Sensors for the Measurement of Water Turbidity

    OpenAIRE

    Mohd Zubir Bin MatJafri; Ahmad Fairuz Bin Omar

    2009-01-01

    Turbidimeters operate based on the optical phenomena that occur when incident light through water body is scattered by the existence of foreign particles which are suspended within it. This review paper elaborates on the standards and factors that may influence the measurement of turbidity. The discussion also focuses on the optical fiber sensor technologies that have been applied within the lab and field environment and have been implemented in the measurement of water turbidity and concentr...

  15. INSTRUMENTS MEASURING PERCEIVED RACISM/RACIAL DISCRIMINATION: REVIEW AND CRITIQUE OF FACTOR ANALYTIC TECHNIQUES

    OpenAIRE

    Atkins, Rahshida

    2014-01-01

    Several compendiums of instruments that measure perceived racism and/or discrimination are present in the literature. Other works have reviewed the psychometric properties of these instruments in terms of validity and reliability and have indicated if the instrument was factor analyzed. However, little attention has been given to the quality of the factor analysis performed. The aim of this study was to evaluate the exploratory factor analyses done on instruments measuring perceived racism/ra...

  16. Measuring and Influencing Physical Activity with Smartphone Technology: A Systematic Review

    OpenAIRE

    Bort Roig, Judit; Gilson, Nicholas D.; Puig Ribera, Anna; Contreras, Ruth S. (Ruth Sofhía); Trost, Stewart G.

    2014-01-01

    Background Rapid developments in technology have encouraged the use of smartphones in physical activity research, although little is known regarding their effectiveness as measurement and intervention tools. Objective This study systematically reviewed evidence on smartphones and their viability for measuring and influencing physical activity. Data Sources Research articles were identified in September 2013 by literature searches in Web of Knowledge, PubMed, PsycINF...

  17. Acute phase proteins: a review of their function, behaviour and measurement in chickens

    OpenAIRE

    O'Reilly, E.L.; Eckersall, P.D.

    2014-01-01

    This review brings together and consolidates the large amount of research on acute phase proteins (APPs) that has been undertaken in chickens. Acute phase proteins are secreted from the liver as a result of inflammation or infection that can be measured in plasma. They have been well-characterised in other farm animal species and have been measured in a wide variety of poultry research areas. The acceleration in chicken APP research is in response to increased interest in ways the immune resp...

  18. What are we assessing when we measure food security? A compendium and review of current metrics.

    Science.gov (United States)

    Jones, Andrew D; Ngure, Francis M; Pelto, Gretel; Young, Sera L

    2013-09-01

    The appropriate measurement of food security is critical for targeting food and economic aid; supporting early famine warning and global monitoring systems; evaluating nutrition, health, and development programs; and informing government policy across many sectors. This important work is complicated by the multiple approaches and tools for assessing food security. In response, we have prepared a compendium and review of food security assessment tools in which we review issues of terminology, measurement, and validation. We begin by describing the evolving definition of food security and use this discussion to frame a review of the current landscape of measurement tools available for assessing food security. We critically assess the purpose/s of these tools, the domains of food security assessed by each, the conceptualizations of food security that underpin each metric, as well as the approaches that have been used to validate these metrics. Specifically, we describe measurement tools that 1) provide national-level estimates of food security, 2) inform global monitoring and early warning systems, 3) assess household food access and acquisition, and 4) measure food consumption and utilization. After describing a number of outstanding measurement challenges that might be addressed in future research, we conclude by offering suggestions to guide the selection of appropriate food security metrics.

  19. National and Regional Surveys of Radon Concentration in Dwellings. Review of Methodology and Measurement Techniques

    International Nuclear Information System (INIS)

    Reliable, comparable and 'fit for purpose' results are essential requirements for any decision based on analytical measurements. For the analyst, the availability of tested and validated sampling and analytical procedures is an extremely important tool for carrying out such measurements. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available to both the analyst and the customer for reference. In the specific case of radon surveys, it is very important to design a survey in such a way as to obtain results that can reasonably be considered representative of a population. Since 2004, the Environment Programme of the IAEA has included activities aimed at the development of a set of procedures for the measurement of radionuclides in terrestrial environmental samples. The development of radon measurement procedures for national and regional surveys started with the collection and review of more than 160 relevant scientific papers. On the basis of this review, this publication summarizes the methodology and the measurement techniques suitable for a population representative national or regional survey on radon concentration in the indoor air of dwellings. The main elements of the survey design are described and discussed, such as the sampling scheme, the protocols, the questionnaire and the data analysis, with particular attention to the potential biases that can affect the representativeness of the results. Moreover, the main measurement techniques suitable for national surveys on indoor radon are reviewed, with particular attention to the elements that can affect the precision and accuracy of the results

  20. Family relationships as an explanatory variable in childhood dental caries: a systematic review of measures.

    Science.gov (United States)

    Duijster, D; O'Malley, L; Elison, S; Van Loveren, C; Marcenes, W; Adair, P M; Pine, C M

    2013-01-01

    It is widely acknowledged that parental beliefs (self-efficacy) about oral health and parental oral health-related behaviours play a fundamental role in the establishment of preventative behaviours that will mitigate against the development of childhood dental caries. However, little attention has been given to the wider perspective of family functioning and family relationships on child oral health. For oral health researchers, exploration of this association requires the use of reliable, valid and appropriate assessment tools to measure family relationships. In order to promote methodologically sound research in oral health, this systematic review aims to provide a guide on self-report psychometric measures of family functioning that may be suitable to utilize when exploring childhood dental caries. This systematic review has identified 29 self-report measures of family functioning and evaluated them in terms of their psychometric support, constructs measured and potential utility for oral health research. The majority of the measures reported adequate levels of reliability and construct validity. Construct evaluation of the measures identified five core domains of family functioning, namely 'communication', 'cohesion/engagement', 'control', 'involvement' and 'authoritative/rigid parenting style'. The constructs were subsequently evaluated with respect to their potential relevance to child oral health. Herewith this review provides a framework to guide future research to explore family functioning in furthering our understanding of the development of childhood dental caries. PMID:24107605

  1. Review of Coping in Children Exposed to Mass Trauma: Measurement Tools, Coping Styles, and Clinical Implications.

    Science.gov (United States)

    Pfefferbaum, Betty; Nitiéma, Pascal; Jacobs, Anne K; Noffsinger, Mary A; Wind, Leslie H; Allen, Sandra F

    2016-04-01

    Evidence-based practice requires the use of data grounded in theory with clear conceptualization and reliable and valid measurement. Unfortunately, developing a knowledge base regarding children's coping in the context of disasters, terrorism, and war has been hampered by a lack of theoretical consensus and a virtual absence of rigorous test construction, implementation, and evaluation. This report presents a comprehensive review of measurement tools assessing child and adolescent coping in the aftermath of mass trauma, with a particular emphasis on coping dimensions identified through factor analytic procedures. Coping measurement and issues related to the assessment of coping are reviewed. Concepts important in instrument development and psychometric features of coping measures used in disasters, terrorism, and war are presented. The relationships between coping dimensions and both youth characteristics and clinical outcomes also are presented. A discussion of the reviewed findings highlights the difficulty clinicians may experience when trying to integrate the inconsistencies in coping dimensions across studies. Incorporating the need for multiple informants and the difference between general and context-specific coping measures suggests the importance of a multilevel, theoretical conceptualization of coping and thus, the use of more advanced statistical measures. Attention also is given to issues deemed important for further exploration in child disaster coping research. PMID:26887259

  2. Measuring Physical Activity in Children and Youth Living with Intellectual Disabilities: A Systematic Review

    Science.gov (United States)

    Hinckson, Erica Aneke; Curtis, Amy

    2013-01-01

    Accurate assessment of physical activity is necessary in determining levels of physical activity in children living with intellectual disability (ID) and assessing effectiveness of intervention programmes. A systematic review of measures of physical activity in children with ID was undertaken using the PRISMA guidelines. MEDLINE-PubMed, Scopus,…

  3. Measuring Person-Centered Care: A Critical Comparative Review of Published Tools

    Science.gov (United States)

    Edvardsson, David; Innes, Anthea

    2010-01-01

    Purpose of the study: To present a critical comparative review of published tools measuring the person-centeredness of care for older people and people with dementia. Design and Methods: Included tools were identified by searches of PubMed, Cinahl, the Bradford Dementia Group database, and authors' files. The terms "Person-centered,"…

  4. Measures used to assess burden among caregivers of stroke patients : a review

    NARCIS (Netherlands)

    Visser-Meily, JMA; Post, MW; Riphagen, [No Value; Lindeman, E

    2004-01-01

    Objective: To describe measures used to evaluate the burden of caregiving experienced by caregivers of stroke patients and their clinimetric properties. Design: A review of the literature was conducted to examine burden scales with regard to concept, feasibility, internal consistency, validity, reli

  5. A review of the current literature on aetiology and measurement methods of halitosis.

    NARCIS (Netherlands)

    Broek, A.M. van den; Feenstra, L.; Baat, C. de

    2007-01-01

    OBJECTIVES: This work reviews the current knowledge of aetiology and measurement methods of halitosis. DATA: Halitosis is an unpleasant or offensive odour emanating from the breath. The condition is multifactorial and may involve both oral and non-oral conditions. SOURCES: A private, monthly with ke

  6. Review on an Advanced High-Temperature Measurement Technology: The Optical Fiber Thermometry

    Directory of Open Access Journals (Sweden)

    Y. B. Yu

    2009-01-01

    Full Text Available Optical fiber thermometry technology for high-temperature measurement is briefly reviewed in this paper. The principles, characteristics, recent progresses and advantages of the technology are described. Examples of using the technology are introduced. Many blackbody, infrared, and fluorescence optical thermometers are developed for practical applications.

  7. Functional status measurement in COPD : a review of available methods and their feasibility in primary care

    NARCIS (Netherlands)

    Kocks, Janwillem W. H.; Asijee, Guus M.; Tsiligianni, Ioanna G.; Kerstjens, Huib A. M.; van der Molen, Thys

    2011-01-01

    Aims: Guidelines advocate that improvement in functional status should be a major goal in COPD treatment. Many tools are available to assess aspects of functional status. This review aims to categorise systematically the available tools based on their construct (i.e. what the tool intends to measure

  8. Investigation of the glide modes of single crystals of beryllium

    International Nuclear Information System (INIS)

    The flow characteristics of single crystals of beryllium specially oriented for slip along a single plane and a single direction have been thoroughly investigated. The elastic limit and the strain hardening in basal glide have been investigated in the temperature range (-195 deg. C, 400 deg. C) in tension as well as in compression. Observation of the slip lines and of the dislocation configurations have also been made in addition to the mechanical tests. The prismatic slip has been studied in greater detail: tensile tests have been performed on specimens carefully oriented at different temperatures, strain rates and with varying orientations of the basal and of the prism planes. Tests have also been made in the micro-strain range; the slip lines and the dislocation arrangements were observed in detail. The very unusual variation of the elastic limit with temperature is not due to impurities but to a cross slip mechanism. A model of dislocation locking is proposed to account for the experimental results. This mechanism assumes that the a-bar dislocations may also dissociate on the prism planes [101-bar 0]. Various possible dissociations are suggested, the most probable of which corresponds to the phase transformation: Hexagonal close packed to body centered cubic. This proposal can be extended to account for the relative ease of glide on the different systems in the hexagonal close packed metals. (author)

  9. Design of the beryllium window for Brookhaven Linac Isotope Producer

    Energy Technology Data Exchange (ETDEWEB)

    Nayak, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Mapes, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Raparia, D. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-11-01

    In the Brookhaven Linac Isotope Producer (BLIP) beam line, there were two Beryllium (Be) windows with an air gap to separate the high vacuum upstream side from low vacuum downstream side. There had been frequent window failures in the past which affected the machine productivity and increased the radiation dose received by workers due to unplanned maintenance. To improve the window life, design of Be window is reexamined. Detailed structural and thermal simulations are carried out on Be window for different design parameters and loading conditions to come up with better design to improve the window life. The new design removed the air gap and connect the both beam lines with a Be window in-between. The new design has multiple advantages such as 1) reduces the beam energy loss (because of one window with no air gap), 2) reduces air activation due to nuclear radiation and 3) increased the machine reliability as there is no direct pressure load during operation. For quick replacement of this window, an aluminum bellow coupled with load binder was designed. There hasn’t been a single window failure since the new design was implemented in 2012.

  10. Manufacture of sintered bricks of high density from beryllium oxide

    International Nuclear Information System (INIS)

    Beryllium oxide bricks of nuclear purity 100 x 100 x 50 and 100 x 100 x 100 mm of very high density (between 2.85 and 3.00) are manufactured by sintering under pressure in graphite moulds at temperatures between 1,750 and 1,850 deg. C, and under a pressure of 150 kg/cm2. The physico-chemical state of the saw material is of considerable importance with regard to the success of the sintering operation. In addition, a study of the sintering of a BeO mixture with 3 to 5 per cent of boron introduced in the form of boric acid, boron carbide or elementary boron shows that high densities can only be obtained by sintering under pressure. For technical reasons of manufacture, only the mixture based on boron carbide is used. The sintering is carried out in graphite moulds at 1500 deg. C under 150 kg/cm2 pressure, and bricks can be obtained with density between 2,85 and 2,90. Laboratory studies and the industrial manufacture of various sinters are described in detail. (author)

  11. Beryllium-induced immune response in C3H mice

    Energy Technology Data Exchange (ETDEWEB)

    Benson, J.M.; Bice, D.E.; Nikula, K.J. [and others

    1995-12-01

    Studies conducted at ITRI over the past several years have investigated whether Beagle dogs, monkeys, and mice are suitable models for human chronic beryllium-induced lung disease (CBD). Recent studies have focused on the histopathological and immunopathological changes occurring in A/J and C3H/HeJ mice acutely exposed by inhalation to Be metal. Lung lesions in both strains of mice included focal lymphocyte aggregates comprised primarily of B lymphocytes and lesser amounts of T-helper lymphocytes and microgranulomas consisting chiefly of macrophages and T-helper lymphocytes. The distribution of proliferating cells within the microgranulomas was similar to the distribution of T-helper cells. These results strongly suggested that A/J and C3H/HeJ mice responded to inhaled Be metal in a fashion similar to humans in terms of pulmonary lesions and the apparent in situ proliferation of T-helper cells. Results of these studies confirm lymphocyte involvement in the pulmonary response to inhaled Be metal.

  12. Project SAPPHIRE uranium-beryllium dose rate analysis

    International Nuclear Information System (INIS)

    During a six-week period in the fall of 1994 a team of 31 US government and Y-12 personnel packaged and removed several thousand kilograms of material containing highly enriched uranium from the (former Soviet Union) Republic of Kazakhstan for interim storage at the Y-12 Plant in Oak Ridge, Tennessee. This classified mission, known as PROJECT SAPPHIRE, had been initiated at the request of the Kazakhstan government in order to rid itself of possible security problems. Planning for the mission included assurance of the health and safety of the team members, as well as compliance with all local, IAEA, and US government regulations regarding the handling, packaging, transportation, and storage of radioactive and fissile material. The mission classification restrictions were relaxed following the return of the team and material to the United States. The material to be removed, in the form of small billets and rods of uranium metal and uranium-beryllium alloy and oxide powder, was sealed by team members on site into two-liter steel cans. Two or three cans each were loaded into more than 400 IAEA certified fissile material shipping container, and each container was packed into a large steel drum for transport by US Air Force cargo planes to the United States

  13. Waterlike structural and excess entropy anomalies in liquid beryllium fluoride.

    Science.gov (United States)

    Agarwal, Manish; Chakravarty, Charusita

    2007-11-22

    The relationship between structural order metrics and the excess entropy is studied using the transferable rigid ion model (TRIM) of beryllium fluoride melt, which is known to display waterlike thermodynamic anomalies. The order map for liquid BeF2, plotted between translational and tetrahedral order metrics, shows a structurally anomalous regime, similar to that seen in water and silica melt, corresponding to a band of state points for which average tetrahedral (q(tet)) and translational (tau) order are strongly correlated. The tetrahedral order parameter distributions further substantiate the analogous structural properties of BeF2, SiO2, and H2O. A region of excess entropy anomaly can be defined within which the pair correlation contribution to the excess entropy (S2) shows an anomalous rise with isothermal compression. Within this region of anomalous entropy behavior, q(tet) and S2 display a strong negative correlation, indicating the connection between the thermodynamic and the structural anomalies. The existence of this region of excess entropy anomaly must play an important role in determining the existence of diffusional and mobility anomalies, given the excess entropy scaling of transport properties observed in many liquids. PMID:17963376

  14. Electron microscope observation of single - crystalline beryllium thin foils; Observation de lames minces monocristallines de beryllium en microscopie electronique

    Energy Technology Data Exchange (ETDEWEB)

    Antolin, J.; Poirier, J.P.; Dupouy, J.M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Thin foils prepared from single crystalline beryllium simples deformed at room temperature, have been observed by transmission electron microscopy. The various deformation modes have been investigated separately, from their early stages and their characteristic dislocation configurations have been observed. Basal slip is characterized at is outset by the presence of numerous dipoles and elongated prismatic loops. More pronounced cold work leads to the formation of dislocation tangles and bundles which eventually give a cellular structure. Prismatic slip begins by the cross-slip of dislocations from the basal plane into the prismatic plane. A cellular structure is equally observed in heavily deformed samples. Sessile dislocations have been observed in twin boundaries; they are produced by reactions between slip dislocations and twin dislocations. Finally, the study of samples quenched from 1100 deg. C and annealed at 200 deg. C has shown that the observed loops lie in prismatic planes and have a Burgers vector b 1/3<1 1 2-bar 0>. (authors) [French] On a observe en microscopie electronique par transmission des lames minces tirees d'eprouvettes monocristallines de beryllium deformees a l'ambiante. On a etudie separement les differents modes de deformation a partir de leur stade elementaire en observant les configurations de dislocations caracteristiques. Le glissement basal est caracterise a son debut par la presence de nombreux dipoles et de boucles prismatiques allongees. Des ecrouissages plus forts conduisent a la formation d'echeveaux et de gerbes qui finissent par donner une structure cellulaire. Le glissement prismatique debute par le glissement des dislocations hors du plan de base dans les plans prismatiques. On trouve egalement une structure cellulaire pour de forts ecrouissages. Dans les joints de macle, on a observe des dislocations sessiles formees par la reaction entre dislocations de macle et dislocations de glissement. Enfin l

  15. Oxidation behavior of plasma sintered beryllium-titanium intermetallic compounds as an advanced neutron multiplier

    Science.gov (United States)

    Kim, Jae-Hwan; Nakamichi, Masaru

    2013-07-01

    Beryllium intermetallic compounds (beryllides) such as Be12Ti are very promising candidates for advanced neutron multiplier materials in a demonstration fusion power reactor (DEMO). However, beryllides are too brittle to be fabricated either into pebble-type or rod-type shapes via conventional methods (i.e. arc melting and hot isostatic pressing). We have proposed a plasma sintering technique as a new method for beryllide fabrication, and our studies on the properties of plasma sintered beryllides are ongoing. In the present work, the oxidation properties of plasma sintered beryllides were investigated at 1273 K for 24 h in a dry air atmosphere to evaluate the high temperature properties of this material. Thermal gravimetry measurements indicate that specimens with larger fractions of Be12Ti phase corresponding to samples that have been sintered for longer time periods, exhibit superior oxidation properties. Our evaluation of the oxidation behavior of each phase in our beryllide samples is as follows: Be12Ti and Be17Ti2 both have good oxidation resistance, owing to the formation of dense and protective scales, while the Be and Be2Ti phases are mainly responsible for thermal-gravimetry (TG) weight gains, which is indicative of severe oxidation. We attribute the degradation in oxidation resistance specifically to Be2Ti that transforms into TiO2, and also find this phase to be the cause of deterioration in the mechanical properties of samples, owing to cracks near Be2Ti phase conglomerates.

  16. Design, manufacture and initial operation of the beryllium components of the JET ITER-like wall

    CERN Document Server

    Riccardo, V; Matthews, G F; Nunes, I; Thompson, V; Villedieu, E; Contributors, JET EFDA

    2013-01-01

    The aim of the JET ITER-like Wall Project was to provide JET with the plasma facing material combination now selected for the DT phase of ITER (bulk beryllium main chamber limiters and a full tungsten divertor) and, in conjunction with the upgraded neutral beam heating system, to achieve ITER relevant conditions. The design of the bulk Be plasma facing components had to be compatible with increased heating power and pulse length, as well as to reuse the existing tile supports originally designed to cope with disruption loads from carbon based tiles and be installed by remote handling. Risk reduction measures (prototypes, jigs, etc) were implemented to maximize efficiency during the shutdown. However, a large number of clashes with existing components not fully captured by the configuration model occurred. Restarting the plasma on the ITER-like Wall proved much easier than for the carbon wall and no deconditioning by disruptions was observed. Disruptions have been more threatening than expected due to the redu...

  17. P-BN/n-Si Heterojunction Prepared by Beryllium ion Implantation

    Institute of Scientific and Technical Information of China (English)

    HE Bin; CHEN Guang-Hua; LI Zhi-Zhong; DENG Jin-Xiang; ZHANG Wun-Jun

    2008-01-01

    A boron nitride(BN)/silicon p-n heterojunction is fabricated by implanting beryllium (Be) ions into the BN films deposited by rf sputtering on n-type Si(111)substrates.The FTIR observations indicate that the films deposited have a mixed phase composition of sp2-and sp3-hybridized BN.Considering the thickness of the BN layer.the ion implantation is conducted at an ion energy of 100ke V with the dose of 5×1015cm-2.After annealing at a high temperature,the surface resistance of the BN film decreases significantly by 6 orders down to 1.2×105Ω.Space-charge-limited current characteristic.which indicates the existence of shallow traps in the film,is observed.Current-voltage measurements across the BN film and the Si substrate reveal a clear rectification feature,demonstrating the achievement of p-type doping of BN films by Be ion implantation.

  18. Halo effective field theory constrains the solar Beryllium-7 + proton -> Boron-8 + photon rate

    CERN Document Server

    Zhang, Xilin; Phillips, D R

    2015-01-01

    We report an improved low-energy extrapolation of the cross section for the process Beryllium-7+proton -> Boron-8+photon, which determines the Boron-8 neutrino flux from the Sun. Our extrapolant is derived from Halo Effective Field Theory (EFT) at next-to-leading order. We apply Bayesian methods to determine the EFT parameters and the low-energy S-factor, using measured cross sections and scattering lengths as inputs. Asymptotic normalization coefficients of Boron-8 are tightly constrained by existing radiative capture data, and contributions to the cross section beyond external direct capture are detected in the data at E < 0.5 MeV. Most importantly, the S-factor at zero energy is constrained to be S(0)= 21.3 + - 0.7 eV b, which is an uncertainty smaller by a factor of two than previously recommended. That recommendation was based on the full range for S(0) obtained among a discrete set of models judged to be reasonable. In contrast, Halo EFT subsumes all models into a controlled low-energy approximant, w...

  19. Mechanical and thermal analysis of beryllium windows for RF cavities in a muon cooling channel

    Energy Technology Data Exchange (ETDEWEB)

    Li, Derun; Ladran, A.; Lozano, D.; Rimmer, R.

    2002-05-30

    Thin beryllium windows (foils) may be utilized to increase shunt impedance of closed-cell RF cavities. These windows are subject to ohmic heating from RF currents. The resulting temperature gradients in the windows can produce out of plane displacements that detune the cavity frequency. The window displacement can be reduced or eliminated by pre-stressing the foils in tension. Because of possible variations during manufacture, it is important to quantify the actual prestress of a Be window before it is put into service. We present the thermal and mechanical analyses of such windows under typical operating conditions and describe a simple non-destructive means to quantify the pre-stress using the acoustic signature of a window. Using finite element analysis, thin plate theory and physical measurements of the vibration modes of a window we attempted to characterize the actual Be window pre-stress in a small number of commercially sourced windows (30% of yield strength is typical). This method can be used for any window material and size, but this study focused on 16 cm diameter Be Windows ranging in thickness from 125 microns to 508 microns and with varying pre-stresses. The method can be used to nondestructively test future Be windows for the desired prestress.

  20. Replacement of the Core Beryllium Reflector in the SAFARI-1 Research Reactor

    International Nuclear Information System (INIS)

    The SAFARI-1 Research Reactor is a 20 MW high flux MTR and has been continuously operational for more than 46 years. In this period, the core beryllium reflector had never been replaced. An ageing management action to replace the reflector received priority due to the risks involved with failure or deformation of elements. This paper elaborates on the actions taken to replace the old and manage the new reflector. To this extent a reflector replacement procedure, backed up by core neutronic calculations and a test plan, was developed for the safe replacement of the reflector. A reflector management programme will ensure that records of reflector elements are kept and used to optimally manage usage of every element. Due to the historic nature of reflector utilisation in the SAFARI-1 core, deformation of the elements was unavoidable. These deformations will be monitored in the management programme for the new reflector. Deformation measurement of the old reflector is planned and could yield interesting comparisons with analytical results. The action plan for final disposal of the old reflector, although still in development, is also mentioned in this paper. (author)

  1. Beryllium geochemistry constraints on the hydraulic behavior of mud volcanoes: the Trinidad Island case

    Science.gov (United States)

    Castrec-Rouelle, M.; Bourlès, D. L.; Boulègue, J.; Dia, A. N.

    2002-11-01

    To constrain Trinidad mud volcanoes hydraulic behavior, both cosmogenic 10Be ( t1/2=1.5 Myr) and 9Be concentrations have been measured in fluid and associated expelled mud. As previously evidenced [A.N. Dia, M. Castrec, J. Boulègue, P. Comeau, Trinidad Mud Volcanoes: where do the expelled fluids come from? Geochim. Cosmochim. Acta 63 (1999) 1023-1038] from δ 18O values and Cl concentrations, 9Be concentrations in the fluids mostly reflect the mixing of two deep components: REM I and REM II. REM I (δ 18O=10.5‰, Cl≈275 mM and 9Be≈0.05 nM) has characteristics of a continental fluid while REM II (δ 18O=3‰, Cl≈350 mM and 9Be≈1 nM) results from seawater-volcanogenic derived sediment interaction. Although 10Be concentrations in the fluid samples are close to the detection limit, the distribution of both beryllium isotopes between the hydroxylamine leachable and residual phases indicates exchange reaction with fluid younger than 15 Myr. Comparison between the lowest REM I 10Be/ 9Be ratio in fluid recorded by the hydroxylamine leachable phase (TD5 mud sample) and the 10Be/ 9Be ratio representative of meteoric contribution in the recharge area (TD8 fluid sample) yields a circulation rate of REM I fluid in the Trinidad mud volcanoes of several 10 -1 m/yr.

  2. Systematic review of patient-reported outcome measures (PROMs) for assessing disease activity in rheumatoid arthritis.

    Science.gov (United States)

    Hendrikx, Jos; de Jonge, Marieke J; Fransen, Jaap; Kievit, Wietske; van Riel, Piet Lcm

    2016-01-01

    Patient assessment of disease activity in rheumatoid arthritis (RA) may be useful in clinical practice, offering a patient-friendly, location independent, and a time-efficient and cost-efficient means of monitoring the disease. The objective of this study was to identify patient-reported outcome measures (PROMs) to assess disease activity in RA and to evaluate the measurement properties of these measures. Systematic literature searches were performed in the PubMed and EMBASE databases to identify articles reporting on clinimetric development or evaluation of PROM-based instruments to monitor disease activity in patients with RA. 2 reviewers independently selected articles for review and assessed their methodological quality based on the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) recommendations. A total of 424 abstracts were retrieved for review. Of these abstracts, 56 were selected for reviewing the full article and 34 articles, presenting 17 different PROMs, were finally included. Identified were: Rheumatoid Arthritis Disease Activity Index (RADAI), RADAI-5, Patient-based Disease Activity Score (PDAS) I & II, Patient-derived Disease Activity Score with 28-joint counts (Pt-DAS28), Patient-derived Simplified Disease Activity Index (Pt-SDAI), Global Arthritis Score (GAS), Patient Activity Score (PAS) I & II, Routine Assessment of Patient Index Data (RAPID) 2-5, Patient Reported Outcome-index (PRO-index) continuous (C) & majority (M), Patient Reported Outcome CLinical ARthritis Activity (PRO-CLARA). The quality of reports varied from poor to good. Typically 5 out of 10 clinimetric domains were covered in the validations of the different instruments. The quality and extent of clinimetric validation varied among PROMs of RA disease activity. The Pt-DAS28, RADAI, RADAI-5 and RAPID 3 had the strongest and most extensive validation. The measurement properties least reported and in need of more evidence were: reliability

  3. The Beryllium-10(meteoric)/ Beryllium-9 ratio as a new tracer of weathering and erosion rates

    Science.gov (United States)

    von Blanckenburg, F.; Bouchez, J.; Wittmann, H.; Dannhaus, N.

    2012-04-01

    from 5 - 10-9 for the Brazilian shield rivers to 2 - 10-10 for the Beni river draining the Andes, corresponding to denudation rates of 0.01mm/yr for the shields and 0.5mm/yr for the Andes, compatible with denudation rates from in situ-produced cosmogenic 10Be [3]. 10-50% of the 9Be was mobilised from bedrock. Once delivered to the ocean, this riverine Be, be it dissolved or reactive, will eventually drive 10Be/9Be ratios of ocean water and disclose global denudation rates - at the present and in the sedimentary record from the past. [1] Willenbring and von Blanckenburg, Nature 465, 2010 [2] Willenbring and von Blanckenburg, Earth Science Reviews 98, 2010 [3] Wittmann et al., Geol Soc. Am. Bull., 123, 2011 [4] Brown, E. et al., Geochim Cosmochim Acta 56, 1992

  4. Inherent structure features of beryllium and their influence on the performance polycrystalline metal under different conditions

    International Nuclear Information System (INIS)

    The anisotropy of physical properties of beryllium single crystals resulting from covalent bonds in crystal lattice leads to significant residual thermal microstresses (RTM) in the polycrystalline metal. It is demonstrated experimentally that there is a simple linear dependence between the magnitude of RTM and the ultimate tensile strength. The factors controlling RTM are analysed and in the framework of powder metallurgy process the technological methods of producing beryllium with the needed properties are recommended. Primarily it is necessary to control the quantity and extent of dispersity of intergranular oxide inclusions and mean grain size in combination with the high degree of macro- and microhomogenity of the structure. The requirements to beryllium microstructure for different operating conditions including neutron fluxes and transient temperature fields are formulated. In the framework of the concept under development one can explain formerly not fully understandable effects, which are characteristic of polycrystalline beryllium such as unexpected Petch-Stro curve, the role of twinning etc., and predict new ones. In particular, it can be possible to expect the growth of ductility of high strength beryllium grades as neutron irradiated. (author)

  5. Solid state bonding of beryllium-copper for an ITER first wall application

    International Nuclear Information System (INIS)

    Several different joint assemblies were evaluated in support of a manufacturing technology for diffusion bonding a beryllium armor tile to a copper alloy heat sink for fusion reactor applications. Because beryllium reacts with all but a few elements to form intermetallic compounds, this study considered several different surface treatments as a means of both inhibiting these reactions and promoting a good diffusion bond between the two substrates. All diffusion bonded assemblies used aluminum or an aluminum-beryllium composite (AlBeMet-150) as the interfacial material in contact with beryllium. In most cases, explosive bonding was utilized as a technique for joining the copper alloy heat sink to an aluminum or AlBeMet-150 substrate, which was subsequently diffusion bonded to an aluminum coated beryllium tile. In this approach, a 250 μm thick titanium foil was used as a diffusion barrier between the copper and aluminum to prevent the formation of Cu-Al intermetallic phases. In all cases, a hot isostatic pressing (HIP) furnace was used in conjunction with canned assemblies in order to minimize oxidation and apply sufficient pressure on the assembly for excellent metal-to-metal contact and subsequent bonding. Several different processing schedules were evaluated during the course of this study; bonded assemblies were produced that failed outside the bond area indicating a 100% joint efficiency. (author)

  6. Clinical approach to chronic beryllium disease and other nonpneumoconiotic interstitial lung diseases.

    Science.gov (United States)

    Maier, Lisa A

    2002-10-01

    Exposures in the workplace result in a diverse set of diseases ranging from the pneumoconiosis to other interstitial lung diseases to acute lung injury. Physician awareness of the potential disease manifestations associated with specific exposures is important in defining these diseases and in preventing additional disease. Most occupational diseases mimic other forms of lung disease, including pulmonary fibrosis, sarcoidosis, adult respiratory distress syndrome (ARDS), and bronchiolitis. A "sarcoidosis"-like syndrome, usually limited to the lungs, may result from exposure to bioaerosols and a number of metals. Exposure to beryllium in the workplace produces a granulomatous lung disease clinically indistinguishable from sarcoidosis, chronic beryllium disease (CBD). Beryllium's ability to produce a beryllium-specific immune response is used in the beryllium lymphocyte proliferation tests to confirm a diagnosis of CBD and exclude sarcoidosis. Exposure to other metals must also be considered in the differential diagnosis of sarcoidosis. When an individual presents acutely with ARDS or acute lung injury, an acute inhalational exposure must be considered. Exposure to a number of irritant substances at high levels may cause a "chemical pneumonitis" or acute lung injury, depending on the solubility and physicochemical properties of the substance. Some of the most notable agents include nitrogen and sulfur oxides, phosgene, and smoke breakdown products. Ingestion of paraquat may also result in an ARDS syndrome, with pulmonary fibrosis eventually resulting. Bronchiolitis is a rare manifestation of inhalational exposures but must also be considered in the clinical evaluation of inhalational exposure. PMID:12362066

  7. Inherent structure features of beryllium and their influence on the performance polycrystalline metal under different conditions

    Energy Technology Data Exchange (ETDEWEB)

    Khomutov, A.M.; Mikhailov, V.S.; Pronin, V.N.; Pakhomov, Ya.D. [State Scientific Center of Russian Federation `A.A. Bochvar All-Russia Research Inst. of Inorganic Materials (VNIINM)`, Moscow (Russian Federation)

    1998-01-01

    The anisotropy of physical properties of beryllium single crystals resulting from covalent bonds in crystal lattice leads to significant residual thermal microstresses (RTM) in the polycrystalline metal. It is demonstrated experimentally that there is a simple linear dependence between the magnitude of RTM and the ultimate tensile strength. The factors controlling RTM are analysed and in the framework of powder metallurgy process the technological methods of producing beryllium with the needed properties are recommended. Primarily it is necessary to control the quantity and extent of dispersity of intergranular oxide inclusions and mean grain size in combination with the high degree of macro- and microhomogenity of the structure. The requirements to beryllium microstructure for different operating conditions including neutron fluxes and transient temperature fields are formulated. In the framework of the concept under development one can explain formerly not fully understandable effects, which are characteristic of polycrystalline beryllium such as unexpected Petch-Stro curve, the role of twinning etc., and predict new ones. In particular, it can be possible to expect the growth of ductility of high strength beryllium grades as neutron irradiated. (author)

  8. Parametric studies of carbon erosion mitigation dynamics in beryllium seeded deuterium plasmas

    International Nuclear Information System (INIS)

    The characteristic time of protective beryllium layer formation on a graphite target, τBe/C, has been investigated as a function of surface temperature, Ts, ion energy, Ei, ion flux, Γi, and beryllium ion concentration, cBe, in beryllium seeded deuterium plasma. τBe/C is found to be strongly decreased with increasing Ts in the range of 550-970K. This is thought to be associated with the more efficient formation of beryllium carbide (Be2C). By scanning the parameters, a scaling expression for τBe/C has been derived as τBe/C[s]=1.0x10-7cBe-1.9+/-0.1Ei0.9+/-0.3Γi-0.6+/-0.3exp ((4.8+/-0.5)x103/Ts) where cBe is dimensionless, Ei in eV, Γi in 1022m-2s-1 and Ts in K. Should this scaling extend to an ITER scenario, carbon erosion of the divertor strike point region may be reduced with characteristic time of ∼6ms. This is much shorter than the time between predicted ITER type I ELMs (∼1s), and suggests that protective beryllium layers can be formed in between ELMs, and mitigate carbon erosion.

  9. Long-term follow-up of beryllium sensitized workers from a single employer

    Directory of Open Access Journals (Sweden)

    Curtis Anne M

    2010-01-01

    Full Text Available Abstract Background Up to 12% of beryllium-exposed American workers would test positive on beryllium lymphocyte proliferation test (BeLPT screening, but the implications of sensitization remain uncertain. Methods Seventy two current and former employees of a beryllium manufacturer, including 22 with pathologic changes of chronic beryllium disease (CBD, and 50 without, with a confirmed positive test were followed-up for 7.4 +/-3.1 years. Results Beyond predicted effects of aging, flow rates and lung volumes changed little from baseline, while DLCO dropped 17.4% of predicted on average. Despite this group decline, only 8 subjects (11.1% demonstrated physiologic or radiologic abnormalities typical of CBD. Other than baseline status, no clinical or laboratory feature distinguished those who clinically manifested CBD at follow-up from those who did not. Conclusions The clinical outlook remains favorable for beryllium-sensitized individuals over the first 5-12 years. However, declines in DLCO may presage further and more serious clinical manifestations in the future. These conclusions are tempered by the possibility of selection bias and other study limitations.

  10. Material selection for extended life of the beryllium reflectors in the JMTR

    International Nuclear Information System (INIS)

    The Japan Materials Test Reactor (JMTR) has been one of the most significant high-energy test reactors in the world since achieving its first criticality in 1968. Beryllium has been used as the reflector element material in the reactor, specifically S-200F structural grade beryllium manufactured by Brush Wellman Inc. The JMTR is currently in the process of being refurbished, and the upgraded reactor will return to service in 2011. As a part of the reactor upgrade, the Japan Atomic Energy Agency (JAEA) also has plans to extend the operating lifetime of the beryllium reflector elements. In order to do that, it will first be necessary to determine which of the material's physical and mechanical properties will be the most influential on that choice. Selecting a different grade of beryllium material for the reflector elements to extend operational lifetime under neutron irradiation is discussed in detail. A new plan for irradiation testing to evaluate the various beryllium grades under consideration is also briefly described. (author)

  11. Manufacturing and thermomechanical testing of actively cooled all beryllium high heat flux test pieces

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, N.N.; Sokolov, Yu.A.; Shatalov, G.E. [and others

    1995-09-01

    One of the problems affiliated to ITER high heat flux elements development is a problem of interface of beryllium protection with heat sink routinely made of copper alloys. To get rid of this problem all beryllium elements could be used as heat receivers in places of enhanced thermal loads. In accordance with this objectives four beryllium test pieces of two types have been manufactured in {open_quotes}Institute of Beryllium{close_quotes} for succeeding thermomechanical testing. Two of them were manufactured in accordance with JET team design; they are round {open_quotes}hypervapotron type{close_quotes} test pieces. Another two ones are rectangular test sections with a twisted tape installed inside of the circular channel. Preliminary stress-strain analysis have been performed for both type of the test pieces. Hypervapotrons have been shipped to JET where they were tested on JET test bed. Thermomechanical testing of pieces of the type of {open_quotes}swirl tape inside of tube{close_quotes} have been performed on Kurchatov Institute test bed. Chosen beryllium grade properties, some details of manufacturing, results of preliminary stress-strain analysis and thermomechanical testing of the test pieces {open_quotes}swirl tape inside of tube{close_quotes} type are given in this report.

  12. Beryllium and lithium resource requirements for solid blanket designs for fusion reactors

    International Nuclear Information System (INIS)

    The lithium and beryllium requirements are analyzed for an economy of 106 MW(e) CTR3 capacity using solid blanket fusion reactors. The total lithium inventory in fusion reactors is only approximately 0.2 percent of projected U. S. resources. The lithium inventory in the fusion reactors is almost entirely 6Li, which must be extracted from natural lithium. Approximately 5 percent of natural lithium can be extracted as 6Li. Thus the total feed of natural lithium required is approximately 20 times that actually used in fusion reactors, or approximately 4 percent of U. S. resources. Almost all of this feed is returned to the U. S. resource base after 6Li is extracted, however. The beryllium requirements are on the order of 10 percent of projected U. S. resources. Further, the present cost of lithium and the cost of beryllium extraction could both be increased tenfold with only minor effects on CTR capital cost. Such an increase should substantially multiply the economically recoverable resources of lithium and beryllium. It is concluded that there are no lithium or beryllium resource limitations preventing large-scale implementation of solid blanket fusion reactors. (U.S.)

  13. Solid state bonding of beryllium-copper for an ITER first wall application

    Energy Technology Data Exchange (ETDEWEB)

    Odegard, B.C. Jr.; Cadden, C.H. [Sandia National Labs., Livermore, CA (United States)

    1998-01-01

    Several different joint assemblies were evaluated in support of a manufacturing technology for diffusion bonding a beryllium armor tile to a copper alloy heat sink for fusion reactor applications. Because beryllium reacts with all but a few elements to form intermetallic compounds, this study considered several different surface treatments as a means of both inhibiting these reactions and promoting a good diffusion bond between the two substrates. All diffusion bonded assemblies used aluminum or an aluminum-beryllium composite (AlBeMet-150) as the interfacial material in contact with beryllium. In most cases, explosive bonding was utilized as a technique for joining the copper alloy heat sink to an aluminum or AlBeMet-150 substrate, which was subsequently diffusion bonded to an aluminum coated beryllium tile. In this approach, a 250 {mu}m thick titanium foil was used as a diffusion barrier between the copper and aluminum to prevent the formation of Cu-Al intermetallic phases. In all cases, a hot isostatic pressing (HIP) furnace was used in conjunction with canned assemblies in order to minimize oxidation and apply sufficient pressure on the assembly for excellent metal-to-metal contact and subsequent bonding. Several different processing schedules were evaluated during the course of this study; bonded assemblies were produced that failed outside the bond area indicating a 100% joint efficiency. (author)

  14. Measures of Transport-Related Social Exclusion: A Critical Review of the Literature

    Directory of Open Access Journals (Sweden)

    Md. Kamruzzaman

    2016-07-01

    Full Text Available Quantitative measures of transport disadvantage are reviewed in this paper from the perspective of their effectiveness to investigate social exclusion. The effectiveness is assessed using criteria derived through a review of the concepts of transport disadvantage and social exclusion and their operationalisation. The specified criteria are related to issues of spatial (e.g., urban accessibility, and public transport accessibility, temporal (e.g., public transport availability, and facility opening hours, and social attributes of travel and activity participation (e.g., personal mobility, and disability. Four groups of transport disadvantage measures are identified and evaluated. These include deprivation-based measures, mobility-based measures, accessibility-based measures, and activity-based measures. The review suggests that although the first three categories of measures have traditionally been used to identify transport disadvantage, they do not satisfy issues surrounding activity participation—the key outcome of social exclusion. The activity space concept is a way in which these issues can be incorporated, as it is a measure of the outcomes of activity participation and their associated travel to that activity. Participation in an activity means that an individual has overcome the spatial, temporal and social barriers of travel for that activity. The research using the activity space concept has, however, inadequately identified individual travel and activity participation. This has been due to a separate application of a range of different indicators to assess activity space size. These indicators are by their nature multidimensional—e.g., area visited, distance travelled, and number of activity sites visited. Although each indicator represents a specific qualitative/quantitative aspect of travel and activity participation, researchers have treated these indicators in an isolated manner to identify transport disadvantage and

  15. Current Options for Measuring the Surface Temperature of Dairy Cattle in a Stable Technology: Review

    Directory of Open Access Journals (Sweden)

    Kateřina Švejdová

    2016-05-01

    Full Text Available Regular measurement of the body surface temperature can help to assess the health status of animals. There are many technological possibilities of contactless temperature measurement of body surface. The important thing is to find the right part of the body whose temperature will point to the first possible symptoms and immediately react to the first signs of the disease. Disagreements about how to measure body surface temperature and accuracy of the method can occur when different measures are used. We review work showing possibilities of contactless surface temperature measurements using 1 thermography, 2 electronic transponders and 3 other possibilities of measuring the body surface temperature of dairy cattle. For example, when we scan the surface temperature with the thermal imager there can operate in individual animals confounding factors such as the nature or degree of muscular coat, which may significantly affect the results.

  16. In vivo and in vitro measurements of pulmonary arterial stiffness: A brief review.

    Science.gov (United States)

    Tian, Lian; Chesler, Naomi C

    2012-10-01

    During the progression of pulmonary hypertension (PH), proximal pulmonary arteries (PAs) undergo remodeling such that they become thicker and the elastic modulus increases. Both of these changes increase the vascular stiffness. The increase in pulmonary vascular stiffness contributes to increased right ventricular (RV) afterload, which causes RV hypertrophy and eventually failure. Studies have found that proximal PA stiffness or its inverse, compliance, is strongly related to morbidity and mortality in patients with PH. Therefore, accurate in vivo measurement of PA stiffness is useful for prognoses in patients with PH. It is also important to understand the structural changes in PAs that occur with PH that are responsible for stiffening. Here, we briefly review the most common parameters used to quantify stiffness and in vivo and in vitro methods for measuring PA stiffness in human and animal models. For in vivo approaches, we review invasive and noninvasive approaches that are based on measurements of pressure and inner or outer diameter or cross-sectional area. For in vitro techniques, we review several different testing methods that mimic one, two or several aspects of physiological loading (e.g., uniaxial and biaxial testing, dynamic inflation-force testing). Many in vivo and in vitro measurement methods exist in the literature, and it is important to carefully choose an appropriate method to measure PA stiffness accurately. Therefore, advantages and disadvantages of each approach are discussed. PMID:23372936

  17. Review of ultraviolet damage threshold measurements at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    The results of damage threshold measurements made at LLNL using ultraviolet wavelength laser pulses are reviewed. Measurements were made with pulses from a krypton fluoride laser with wavelength of 248 nm and pulse duration of 20 ns and with Nd-glass laser pulses converted to the third harmonic wavelength of 355 nm with duration of 0.6 ns. Measurements are presented for transparent window materials, crystals and harmonic generation, single layer dielectric films of oxide and fluoride materials and multilayer high reflectivity and antireflective coatings

  18. How is recovery from low back pain measured? A systematic review of the literature

    OpenAIRE

    Kamper, Steven J.; Stanton, Tasha R.; Christopher M Williams; Christopher G. Maher; Hush, Julia M

    2010-01-01

    Recovery is commonly used as an outcome measure in low back pain (LBP) research. There is, however, no accepted definition of what recovery involves or guidance as to how it should be measured. The objective of the study was designed to appraise the LBP literature from the last 10 years to review the methods used to measure recovery. The research design includes electronic searches of Medline, EMBASE, CINAHL, Cochrane database of clinical trials and PEDro from the beginning of 1999 to Decembe...

  19. Measurement properties of patient-reported outcome measures (PROMs) in adults with obstructive sleep apnea (OSA): A systematic review.

    Science.gov (United States)

    Abma, Inger L; van der Wees, Philip J; Veer, Vik; Westert, Gert P; Rovers, Maroeska

    2016-08-01

    This systematic review summarizes the evidence regarding the quality of patient-reported outcome measures (PROMs) validated in patients with obstructive sleep apnea (OSA). We performed a systematic literature search of all PROMs validated in patients with OSA, and found 22 measures meeting our inclusion criteria. The quality of the studies was assessed using the consensus-based standards for the selection of health status measurement instruments (COSMIN) checklist. The results showed that most of the measurement properties of the PROMs were not, or not adequately, assessed. For many identified PROMs there was no involvement of patients with OSA during their development or before the PROM was tested in patients with OSA. Positive exceptions and the best current candidates for assessing health status in patients with OSA are the sleep apnea quality of life index (SAQLI), Maugeri obstructive sleep apnea syndrome (MOSAS) questionnaire, Quebec sleep questionnaire (QSQ) and the obstructive sleep apnea patient-oriented severity index (OSAPOSI). Even though there is not enough evidence to fully judge the quality of these PROMs as outcome measure, when interpreted with caution, they have the potential to add value to clinical research and clinical practice in evaluating aspects of health status that are important to patients. PMID:26433776

  20. Review of the ITER diagnostics suite for erosion, deposition, dust and tritium measurements

    Energy Technology Data Exchange (ETDEWEB)

    Reichle, R., E-mail: roger.reichle@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Andrew, P. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Bates, P. [F4E, Torres Diagonal Litoral B3, Barcelona (Spain); Bede, O.; Casal, N.; Choi, C.H.; Barnsley, R. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Damiani, C. [F4E, Torres Diagonal Litoral B3, Barcelona (Spain); Bertalot, L. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Dubus, G. [F4E, Torres Diagonal Litoral B3, Barcelona (Spain); Ferreol, J.; Jagannathan, G.; Kocan, M.; Leipold, F.; Lisgo, S.W.; Martin, V.; Palmer, J.; Pearce, R. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Philipps, V. [Institut für Energieforschung – Plasmaphysik, Forschungszentrum Jülich GmbH, Association EURATOM – Forschungszentrum Jülich, D-52425 Jülich (Germany); Pitts, R.A. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); and others

    2015-08-15

    Dust and tritium inventories in the vacuum vessel have upper limits in ITER that are set by nuclear safety requirements. Erosion, migration and re-deposition of wall material together with fuel co-deposition will be largely responsible for these inventories. The diagnostic suite required to monitor these processes, along with the set of the corresponding measurement requirements is currently under review given the recent decision by the ITER Organization to eliminate the first carbon/tungsten (C/W) divertor and begin operations with a full-W variant Pitts et al. [1]. This paper presents the result of this review as well as the status of the chosen diagnostics.