WorldWideScience

Sample records for battery test results

  1. Experimental Test Campaign on a Battery Electric Vehicle: On-Road Test Results (Part 2)

    OpenAIRE

    PAFFUMI Elena; DE GENNARO MICHELE; MARTINI Giorgio; MANFREDI URBANO; VIANELLI Stefano; ORTENZI Fernando; GENOVESE Antonino

    2014-01-01

    The experimental measurement of the energy consumption and efficiency of Battery Electric Vehicles (BEVs) are key topics to determine their usability and performance in real-world conditions. This paper aims to present the results of a test campaign carried out on a BEV, representative of the most common technology available today on the market. The vehicle is a 5-seat car, equipped with an 80 kW synchronous electric motor powered by a 24 kWh Li-Ion battery. The description and discussion of ...

  2. 2010 Toyota Prius VIN 6063 Hybrid Electric Vehicle Battery Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Toyota Prius HEV (VIN JTDKN3DU5A0006063). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Program of the U.S. Department of Energy.

  3. Battery testing for photovoltaic applications

    Energy Technology Data Exchange (ETDEWEB)

    Hund, T.

    1996-11-01

    Battery testing for photovoltaic (PV) applications is funded at Sandia under the Department of Energy`s (DOE) Photovoltaic Balance of Systems (BOS) Program. The goal of the PV BOS program is to improve PV system component design, operation, reliability, and to reduce overall life-cycle costs. The Sandia battery testing program consists of: (1) PV battery and charge controller market survey, (2) battery performance and life-cycle testing, (3) PV charge controller development, and (4) system field testing. Test results from this work have identified market size and trends, PV battery test procedures, application guidelines, and needed hardware improvements.

  4. Selected test results from the neosonic polymer Li-ion battery.

    Energy Technology Data Exchange (ETDEWEB)

    Ingersoll, David T.; Hund, Thomas D.

    2010-07-01

    The performance of the Neosonic polymer Li-ion battery was measured using a number of tests including capacity, capacity as a function of temperature, ohmic resistance, spectral impedance, hybrid pulsed power test, utility partial state of charge (PSOC) pulsed cycle test, and an over-charge/voltage abuse test. The goal of this work was to evaluate the performance of the polymer Li-ion battery technology for utility applications requiring frequent charges and discharges, such as voltage support, frequency regulation, wind farm energy smoothing, and solar photovoltaic energy smoothing. Test results have indicated that the Neosonic polymer Li-ion battery technology can provide power levels up to the 10C{sub 1} discharge rate with minimal energy loss compared to the 1 h (1C) discharge rate. Two of the three cells used in the utility PSOC pulsed cycle test completed about 12,000 cycles with only a gradual loss in capacity of 10 and 13%. The third cell experienced a 40% loss in capacity at about 11,000 cycles. The DC ohmic resistance and AC spectral impedance measurements also indicate that there were increases in impedance after cycling, especially for the third cell. Cell No.3 impedance Rs increased significantly along with extensive ballooning of the foil pouch. Finally, at a 1C (10 A) charge rate, the over charge/voltage abuse test with cell confinement similar to a multi cell string resulted in the cell venting hot gases at about 45 C 45 minutes into the test. At 104 minutes into the test the cell voltage spiked to the 12 volt limit and continued out to the end of the test at 151 minutes. In summary, the Neosonic cells performed as expected with good cycle-life and safety.

  5. Interpreting in vitro developmental toxicity test battery results: The consideration of toxicokinetics.

    Science.gov (United States)

    Bosgra, Sieto; Westerhout, Joost

    2015-08-01

    In the EU collaborative project ChemScreen an alternative, in vitro assay-based test strategy was developed to screen compounds for reproductive toxicity. A toxicokinetic modeling approach was used to allow quantitative comparison between effective concentrations in the in vitro test battery and observations of developmental toxicity in vivo. This modeling strategy is based on (1) the definition of relevant observations of toxicity in vivo, (2) simulation of the corresponding systemic concentrations in vivo by toxicokinetic modeling, and (3) correction for differences in protein binding and lipid partitioning between plasma and in vitro test media. The test results of a feasibility study with a number of known reproductive toxicants has been described previously (Piersma et al. [15]). In the present paper, we take a more detailed look at the toxicokinetics of these compounds, and add the analysis of some compounds from subsequent studies. We discuss how the consideration of toxicokinetics allowed comparison between test systems with differing test medium composition, has helped to interpret the in vitro findings in light of in vivo observations, and to gain confidence in the predictive value of the test battery outcomes. The same toxicokinetic modeling strategy, in reverse order, can now be used for risk assessment purposes to predict toxic doses in vivo from effective concentrations in vitro. PMID:25462785

  6. Selected test results from the LiFeBatt iron phosphate Li-ion battery.

    Energy Technology Data Exchange (ETDEWEB)

    Ingersoll, David T.; Hund, Thomas D.

    2008-09-01

    In this paper the performance of the LiFeBatt Li-ion cell was measured using a number of tests including capacity measurements, capacity as a function of temperature, ohmic resistance, spectral impedance, high power partial state of charge (PSOC) pulsed cycling, pulse power measurements, and an over-charge/voltage abuse test. The goal of this work was to evaluate the performance of the iron phosphate Li-ion battery technology for utility applications requiring frequent charges and discharges, such as voltage support, frequency regulation, and wind farm energy smoothing. Test results have indicated that the LiFeBatt battery technology can function up to a 10C{sub 1} discharge rate with minimal energy loss compared to the 1 h discharge rate (1C). The utility PSOC cycle test at up to the 4C{sub 1} pulse rate completed 8,394 PSOC pulsed cycles with a gradual loss in capacity of 10 to 15% depending on how the capacity loss is calculated. The majority of the capacity loss occurred during the initial 2,000 cycles, so it is projected that the LiFeBatt should PSOC cycle well beyond 8,394 cycles with less than 20% capacity loss. The DC ohmic resistance and AC spectral impedance measurements also indicate that there were only very small changes after cycling. Finally, at a 1C charge rate, the over charge/voltage abuse test resulted in the cell venting electrolyte at 110 C after 30 minutes and then open-circuiting at 120 C with no sparks, fire, or voltage across the cell.

  7. Propagation testing multi-cell batteries.

    Energy Technology Data Exchange (ETDEWEB)

    Orendorff, Christopher J.; Lamb, Joshua; Steele, Leigh Anna Marie; Spangler, Scott Wilmer

    2014-10-01

    Propagation of single point or single cell failures in multi-cell batteries is a significant concern as batteries increase in scale for a variety of civilian and military applications. This report describes the procedure for testing failure propagation along with some representative test results to highlight the potential outcomes for different battery types and designs.

  8. Vehicles testing of near-term batteries

    Science.gov (United States)

    Conover, R. C.; Hardy, K. S.; Sandberg, J. J.

    1980-01-01

    Vehicles test results are reported for nickel-iron, nickel-zinc, and improved lead-acid batteries developed under the Near-Term Battery Program sponsored by the Department of Energy. The batteries have demonstrated a range improvement of up to 90% over current lead-acid batteries due to improved energy density and ampere-hour capacity, combined with relatively small weight and volume. However, the nickel-iron battery requires a substantial development effort in packaging the circulating electrolyte system and handling the generated hydrogen volume, while the nickel-zinc batteries tested suffer from short cycle life.

  9. Battery Post-Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Post-test diagnostics of aged batteries can provide additional information regarding the cause of performance degradation, which, previously, could be only inferred...

  10. JPL's electric and hybrid vehicles project: Project activities and preliminary test results. [power conditioning and battery charge efficiency

    Science.gov (United States)

    Barber, T. A.

    1980-01-01

    Efforts to achieve a 100 mile urban range, to reduce petroleum usage 40% to 70%, and to commercialize battery technology are discussed with emphasis on an all plastic body, four passenger car that is flywheel assisted and battery powered, and on an all metal body, four passenger car with front wheel drive and front motor. For the near term case, a parallel hybrid in which the electric motor and the internal combustion engine may directly power the drive wheels, is preferred to a series design. A five passenger car in which the electric motor and the gasoline engine both feed into the same transmission is discussed. Upgraded demonstration vehicles were tested using advanced lead acid, nickel zinc, nickel iron, and zinc chloride batteries to determine maximum acceleration, constant speed, and battery behavior. The near term batteries demonstrated significant improvement relative to current lead acid batteries. The increase in range was due to improved energy density, and ampere hour capacity, with relatively 1 small weight and volume differences.

  11. A field operational test on valve-regulated lead-acid absorbent-glass-mat batteries in micro-hybrid electric vehicles. Part II. Results based on multiple regression analysis and tear-down analysis

    Science.gov (United States)

    Schaeck, S.; Karspeck, T.; Ott, C.; Weirather-Koestner, D.; Stoermer, A. O.

    2011-03-01

    In the first part of this work [1] a field operational test (FOT) on micro-HEVs (hybrid electric vehicles) and conventional vehicles was introduced. Valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology and flooded batteries were applied. The FOT data were analyzed by kernel density estimation. In this publication multiple regression analysis is applied to the same data. Square regression models without interdependencies are used. Hereby, capacity loss serves as dependent parameter and several battery-related and vehicle-related parameters as independent variables. Battery temperature is found to be the most critical parameter. It is proven that flooded batteries operated in the conventional power system (CPS) degrade faster than VRLA-AGM batteries in the micro-hybrid power system (MHPS). A smaller number of FOT batteries were applied in a vehicle-assigned test design where the test battery is repeatedly mounted in a unique test vehicle. Thus, vehicle category and specific driving profiles can be taken into account in multiple regression. Both parameters have only secondary influence on battery degradation, instead, extended vehicle rest time linked to low mileage performance is more serious. A tear-down analysis was accomplished for selected VRLA-AGM batteries operated in the MHPS. Clear indications are found that pSoC-operation with periodically fully charging the battery (refresh charging) does not result in sulphation of the negative electrode. Instead, the batteries show corrosion of the positive grids and weak adhesion of the positive active mass.

  12. Testing batteries for photovoltaic power systems

    Science.gov (United States)

    Verardo, A. E.; Butler, P. C.; Bush, D. M.; Miller, D. W.

    A battery evaluation laboratory was established to investigate the application of various battery technologies for energy storage in a photovoltaic power system. The evaluation laboratory provides a controlled test environment in which batteries can be exposed to any one or all of the following: (1) long term performance testing; (2) accelerated life testing; (3) simulated photovoltaic power system operational testing. Several battery systems are being tested. A description is presented of the laboratory and the tests currently being conducted and a brief description of the battery systems under test.

  13. A web application for follow-up of results from a mobile device test battery for parkinson’s disease patients

    OpenAIRE

    Memedi, Mevludin; Westin, Jerker; Nyholm, Dag; Dougherty, Mark; Groth, Torgny

    2010-01-01

    Background: A test battery consisting of self-assessments and motor tests (tapping and spiral drawing) was developed for a hand computer with touch screen in a telemedicine setting. Objectives: To develop and evaluate a web-based system that delivers decision support information to the treating clinical staff for assessing PD symptoms in their patients based on the test battery data. Methods: The test battery is currently being used in a clinical trial (DAPHNE, EudraCT No. 2005-002654-21) by ...

  14. Testing activities at the National Battery Test Laboratory

    Science.gov (United States)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  15. Cursor Control Device Test Battery

    Science.gov (United States)

    Holden, Kritina; Sandor, Aniko; Pace, John; Thompson, Shelby

    2013-01-01

    The test battery was developed to provide a standard procedure for cursor control device evaluation. The software was built in Visual Basic and consists of nine tasks and a main menu that integrates the set-up of the tasks. The tasks can be used individually, or in a series defined in the main menu. Task 1, the Unidirectional Pointing Task, tests the speed and accuracy of clicking on targets. Two rectangles with an adjustable width and adjustable center- to-center distance are presented. The task is to click back and forth between the two rectangles. Clicks outside of the rectangles are recorded as errors. Task 2, Multidirectional Pointing Task, measures speed and accuracy of clicking on targets approached from different angles. Twenty-five numbered squares of adjustable width are arranged around an adjustable diameter circle. The task is to point and click on the numbered squares (placed on opposite sides of the circle) in consecutive order. Clicks outside of the squares are recorded as errors. Task 3, Unidirectional (horizontal) Dragging Task, is similar to dragging a file into a folder on a computer desktop. Task 3 requires dragging a square of adjustable width from one rectangle and dropping it into another. The width of each rectangle is adjustable, as well as the distance between the two rectangles. Dropping the square outside of the rectangles is recorded as an error. Task 4, Unidirectional Path Following, is similar to Task 3. The task is to drag a square through a tunnel consisting of two lines. The size of the square and the width of the tunnel are adjustable. If the square touches any of the lines, it is counted as an error and the task is restarted. Task 5, Text Selection, involves clicking on a Start button, and then moving directly to the underlined portion of the displayed text and highlighting it. The pointing distance to the text is adjustable, as well as the to-be-selected font size and the underlined character length. If the selection does not

  16. Aging evaluation of class 1E batteries: Seismic testing

    Energy Technology Data Exchange (ETDEWEB)

    Edson, J.L. (EG and G Idaho, Inc., Idaho Falls, ID (USA))

    1990-08-01

    This report presents the results of a seismic testing program on naturally aged class 1E batteries obtained from a nuclear plant. The testing program is a Phase 2 activity resulting from a Phase 1 aging evaluation of class 1E batteries in safety systems of nuclear power plants, performed previously as a part of the US Nuclear Regulatory Commission's Nuclear Plant Aging Research Program and reported in NUREG/CR-4457. The primary purpose of the program was to evaluate the seismic ruggedness of naturally aged batteries to determine if aged batteries could have adequate electrical capacity, as determined by tests recommended by IEEE Standards, and yet have inadequate seismic ruggedness to provide needed electrical power during and after a safe shutdown earthquake (SSE) event. A secondary purpose of the program was to evaluate selected advanced surveillance methods to determine if they were likely to be more sensitive to the aging degradation that reduces seismic ruggedness. The program used twelve batteries naturally aged to about 14 years of age in a nuclear facility and tested them at four different seismic levels representative of the levels of possible earthquakes specified for nuclear plants in the United States. Seismic testing of the batteries did not cause any loss of electrical capacity. 19 refs., 29 figs., 7 tabs.

  17. Aging evaluation of class 1E batteries: Seismic testing

    International Nuclear Information System (INIS)

    This report presents the results of a seismic testing program on naturally aged class 1E batteries obtained from a nuclear plant. The testing program is a Phase 2 activity resulting from a Phase 1 aging evaluation of class 1E batteries in safety systems of nuclear power plants, performed previously as a part of the US Nuclear Regulatory Commission's Nuclear Plant Aging Research Program and reported in NUREG/CR-4457. The primary purpose of the program was to evaluate the seismic ruggedness of naturally aged batteries to determine if aged batteries could have adequate electrical capacity, as determined by tests recommended by IEEE Standards, and yet have inadequate seismic ruggedness to provide needed electrical power during and after a safe shutdown earthquake (SSE) event. A secondary purpose of the program was to evaluate selected advanced surveillance methods to determine if they were likely to be more sensitive to the aging degradation that reduces seismic ruggedness. The program used twelve batteries naturally aged to about 14 years of age in a nuclear facility and tested them at four different seismic levels representative of the levels of possible earthquakes specified for nuclear plants in the United States. Seismic testing of the batteries did not cause any loss of electrical capacity. 19 refs., 29 figs., 7 tabs

  18. Test Report : GS battery, EPC power HES RESCU.

    Energy Technology Data Exchange (ETDEWEB)

    Rose, David Martin; Schenkman, Benjamin L.; Borneo, Daniel R.

    2013-10-01

    The Department of Energy Office of Electricity (DOE/OE), Sandia National Laboratories (SNL) and the Base Camp Integration Lab (BCIL) partnered together to incorporate an energy storage system into a microgrid configured Forward Operating Base to reduce the fossil fuel consumption and to ultimately save lives. Energy storage vendors will be sending their systems to SNL Energy Storage Test Pad (ESTP) for functional testing and then to the BCIL for performance evaluation. The technologies that will be tested are electro-chemical energy storage systems comprising of lead acid, lithium-ion or zinc-bromide. GS Battery and EPC Power have developed an energy storage system that utilizes zinc-bromide flow batteries to save fuel on a military microgrid. This report contains the testing results and some limited analysis of performance of the GS Battery, EPC Power HES RESCU.

  19. Results of cycling with battery charging management; Resultats de cyclage avec gestion de charge au niveau batterie

    Energy Technology Data Exchange (ETDEWEB)

    Verniolle, J.; Fernandez, C. [European Space Research and Technology Centre, Noordwijk (Netherlands)

    1996-12-31

    In order to investigate the charging mode of an in-series assembly of lithium-carbon battery cells, a test has been performed on 5 commercial cells (18650) of 0.95 Ah nominal capacity. Results show that it is possible to cycle the cells at 80% of their output capacities during more than 2000 cycles. The management of the battery consists in maintaining a constant battery voltage as soon as a cell reaches its limit voltage during constant current charging. The initial dispersion of cells has been maintained practically constant during the cycling and the charge state of all cells has decreased progressively. (J.S.)

  20. The utility of the Revised Nonreading Aptitude Test Battery vs. the General Aptitude Test Battery

    OpenAIRE

    Barber, Robert M.

    1990-01-01

    The study focused on the aptitude test performances of intellectually sub-normal subjects on the Nonreading Aptitude Test Battery (R-NATB) vs. the General Aptitude Test Battery (GATB). There were two research questions investigated: (1) Are there performance differences on the RNATB vs. GATB of borderline and/or mildly retarded individuals?, and (2) Is the Wide Range Achievement Test-Revised (WRAT-R) a better predictor than the Wide Range Scale (WRS) of R-NATB and/or GATB aptitude performa...

  1. Potential use of battery packs from NCAP tested vehicles.

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, Joshua; Orendorff, Christopher J.

    2013-10-01

    Several large electric vehicle batteries available to the National Highway Traffic Safety Administration are candidates for use in future safety testing programs. The batteries, from vehicles subjected to NCAP crashworthiness testing, are considered potentially damaged due to the nature of testing their associated vehicles have been subjected to. Criteria for safe shipping to Sandia is discussed, as well as condition the batteries must be in to perform testing work. Also discussed are potential tests that could be performed under a variety of conditions. The ultimate value of potential testing performed on these cells will rest on the level of access available to the battery pack, i.e. external access only, access to the on board monitoring system/CAN port or internal electrical access to the battery. Greater access to the battery than external visual and temperature monitoring would likely require input from the battery manufacturer.

  2. A field operational test on valve-regulated lead-acid absorbent-glass-mat batteries in micro-hybrid electric vehicles. Part I. Results based on kernel density estimation

    Science.gov (United States)

    Schaeck, S.; Karspeck, T.; Ott, C.; Weckler, M.; Stoermer, A. O.

    2011-03-01

    In March 2007 the BMW Group has launched the micro-hybrid functions brake energy regeneration (BER) and automatic start and stop function (ASSF). Valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology are applied in vehicles with micro-hybrid power system (MHPS). In both part I and part II of this publication vehicles with MHPS and AGM batteries are subject to a field operational test (FOT). Test vehicles with conventional power system (CPS) and flooded batteries were used as a reference. In the FOT sample batteries were mounted several times and electrically tested in the laboratory intermediately. Vehicle- and battery-related diagnosis data were read out for each test run and were matched with laboratory data in a data base. The FOT data were analyzed by the use of two-dimensional, nonparametric kernel estimation for clear data presentation. The data show that capacity loss in the MHPS is comparable to the CPS. However, the influence of mileage performance, which cannot be separated, suggests that battery stress is enhanced in the MHPS although a battery refresh function is applied. Anyway, the FOT demonstrates the unsuitability of flooded batteries for the MHPS because of high early capacity loss due to acid stratification and because of vanishing cranking performance due to increasing internal resistance. Furthermore, the lack of dynamic charge acceptance for high energy regeneration efficiency is illustrated. Under the presented FOT conditions charge acceptance of lead-acid (LA) batteries decreases to less than one third for about half of the sample batteries compared to new battery condition. In part II of this publication FOT data are presented by multiple regression analysis (Schaeck et al., submitted for publication [1]).

  3. The USAF Phillips Laboratory sodium-sulfur battery technology program: Results and status

    Science.gov (United States)

    Rainbow, Marc E.; Somerville, Andrew

    1996-01-01

    Tests performed on NaS batteries are reported. The results of safety and abuse testing, shock and vibration tests, cell failure on warm-up, freeze thaw, overtemperature conditions, electrolyte fracture, overdischarge, and short circuit tests are presented along with GEO and LEO cycle tests and the status of the NaS cell flight tests.

  4. Idling-stop vehicle road tests of advanced valve-regulated lead-acid (VRLA) battery

    Science.gov (United States)

    Sawai, Ken; Ohmae, Takao; Suwaki, Hironori; Shiomi, Masaaki; Osumi, Shigeharu

    The results of road tests on valve-regulated lead-acid (VRLA) batteries in an idling-stop (stop and go) vehicle are reported. Idling-stop systems are simple systems to improve fuel economy of automobiles. They are expected to spread widely from an environmental perspective. Performances of a conventional flooded battery, a conventional VRLA battery, and an improved VRLA battery were compared in road tests with an idling-stop vehicle. It was found that the improved VRLA battery was suited to idling-stop applications because it had a smaller capacity loss than the conventional flooded battery during partial-state-of-charge (PSoC) operation. The positive grid was corroded in layers, unlike the usual grain boundary corrosion of SLI battery grid. It is because the corrosion proceeded mainly under PSoC conditions. The corrosion rate could be controlled by potential control of positive plates.

  5. Idling-stop vehicle road tests of advanced valve-regulated lead-acid (VRLA) battery

    Energy Technology Data Exchange (ETDEWEB)

    Sawai, Ken; Ohmae, Takao; Suwaki, Hironori; Shiomi, Masaaki; Osumi, Shigeharu [Technical Development Division, Automotive Battery Business Unit, GS Yuasa Power Supply Ltd., Nishinosho, Kisshoin, Minami-ku, Kyoto (Japan)

    2007-11-22

    The results of road tests on valve-regulated lead-acid (VRLA) batteries in an idling-stop (stop and go) vehicle are reported. Idling-stop systems are simple systems to improve fuel economy of automobiles. They are expected to spread widely from an environmental perspective. Performances of a conventional flooded battery, a conventional VRLA battery, and an improved VRLA battery were compared in road tests with an idling-stop vehicle. It was found that the improved VRLA battery was suited to idling-stop applications because it had a smaller capacity loss than the conventional flooded battery during partial-state-of-charge (PSoC) operation. The positive grid was corroded in layers, unlike the usual grain boundary corrosion of SLI battery grid. It is because the corrosion proceeded mainly under PSoC conditions. The corrosion rate could be controlled by potential control of positive plates. (author)

  6. Electrochemical test methods for advanced battery and semiconductor technology

    Science.gov (United States)

    Hsu, Chao-Hung

    This dissertation consists of two studies. The first study was the evaluation of metallic materials for advanced lithium ion batteries and the second study was the determination of the dielectric constant k for the low-k materials. The advanced lithium ion battery is miniature for implantable medical devices and capable of being recharged from outside of the body using magnetic induction without physical connections. The stability of metallic materials employed in the lithium ion battery is one of the major safety concerns. Three types of materials---Pt-Ir alloy, Ti alloys, and stainless steels---were evaluated extensively in this study. The electrochemical characteristics of Pt-Ir alloy, Ti alloys, and stainless steels were evaluated in several types of battery electrolytes in order to determine the candidate materials for long-term use in lithium ion batteries. The dissolution behavior of these materials and the decomposition behavior of the battery electrolyte were investigated using the anodic potentiodynamic polarization (APP) technique. Lifetime prediction for metal dissolution was conducted using constant potential polarization (CPP) technique. The electrochemical impedance spectroscopy (EIS) technique was employed to investigate the metal dissolution behavior or the battery electrolyte decomposition at the open circuit potential (OCP). The scanning electron microscope (SEM) was used to observe the morphology changes after these tests. The effects of experimental factors on the corrosion behaviors of the metallic materials and stabilities of the battery electrolytes were also investigated using the 23 factorial design approach. Integration of materials having low dielectric constant k as interlayer dielectrics and/or low-resistivity conductors will partially solve the RC delay problem for the limiting performance of high-speed logic chips. The samples of JSR LKD 5109 material capped by several materials were evaluated by using EIS. The feasibility of using

  7. Cell overcharge testing inside sodium metal halide battery

    Science.gov (United States)

    Frutschy, Kris; Chatwin, Troy; Bull, Roger

    2015-09-01

    Testing was conducted to measure electrical performance and safety of the General Electric Durathon™ E620 battery module (600 V class 20 kWh) during cell overcharge. Data gathered from this test was consistent with SAE Electric Vehicle Battery Abuse Testing specification J2464 [1]. After cell overcharge failure and 24 A current flow for additional 60 minutes, battery was then discharged at 7.5 KW average power to 12% state of charge (SOC) and recharged back to 100% SOC. This overcharging test was performed on two cells. No hydrogen chloride (HCl) gas was detected during front cell (B1) test, and small amount (6.2 ppm peak) was measured outside the battery after center cell (F13) overcharge. An additional overcharge test was performed per UL Standard 1973 - Batteries for Use in Light Electric Rail (LER) Applications and Stationary Applications[2]. With the battery at 11% SOC and 280 °C float temperature, an individual cell near the front (D1) was deliberately imbalanced by charging it to 62% SOC. The battery was then recharged to 100% SOC. In all three tests, the battery cell pack was stable and individual cell failure did not propagate to other cells. Battery discharge performance, charge performance, and electrical isolation were normal after all three tests.

  8. Development of a Valid Volleyball Skills Test Battery.

    Science.gov (United States)

    Bartlett, Jackie; And Others

    1991-01-01

    Describes the development of the North Carolina State University Volleyball Skills Test Battery which offers accurate measurement of three volleyball skills (serve, forearm pass, and set). When physical educators tested 313 students, the battery objectively measured their abilities, providing a gamelike means of teaching, testing, grouping, and…

  9. Cholesterol testing and results

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000386.htm Cholesterol testing and results To use the sharing features ... can tell you what your goal should be. Cholesterol Tests Some cholesterol is considered good and some ...

  10. Foothill Transit Battery Electric Bus Demonstration Results

    Energy Technology Data Exchange (ETDEWEB)

    Eudy, Leslie [National Renewable Energy Lab. (NREL), Golden, CO (United States); Prohaska, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kelly, Kenneth [National Renewable Energy Lab. (NREL), Golden, CO (United States); Post, Matthew [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-01-27

    Foothill Transit is collaborating with the California Air Resources Board and the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) to evaluate its fleet of Proterra battery electric buses (BEBs) in revenue service. The focus of this evaluation is to compare performance of the BEBs to that of conventional technology and to track progress over time toward meeting performance targets. This project has also provided an opportunity for DOE to conduct a detailed evaluation of the BEBs and charging infrastructure. This report provides data on the buses from April 2014 through July 2015. Data are provided on a selection of compressed natural gas buses as a baseline comparison.

  11. A Review of the Nonreading Aptitude Test Battery

    Science.gov (United States)

    Steckler, Victor

    1973-01-01

    This article re-examines data from the Nonreading Aptitude Test Battery (NATB) and General Aptitude Battery (GATB) test manuals in light of some conventionally accepted psychometric considerations. It is recommended that caution be employed in relating NATB profiles to the Occupational Aptitude Patterns' norms. (Author)

  12. Empirical Modeling of Lithium-ion Batteries Based on Electrochemical Impedance Spectroscopy Tests

    International Nuclear Information System (INIS)

    Highlights: • Two commercial Lithium-ion batteries are studied through HPPC and EIS tests. • An equivalent circuit model is developed for a range of operating conditions. • This model improves the current battery empirical models for vehicle applications • This model is proved to be efficient in terms of predicting HPPC test resistances. - ABSTRACT: An empirical model for commercial lithium-ion batteries is developed based on electrochemical impedance spectroscopy (EIS) tests. An equivalent circuit is established according to EIS test observations at various battery states of charge and temperatures. A Laplace transfer time based model is developed based on the circuit which can predict the battery operating output potential difference in battery electric and plug-in hybrid vehicles at various operating conditions. This model demonstrates up to 6% improvement compared to simple resistance and Thevenin models and is suitable for modeling and on-board controller purposes. Results also show that this model can be used to predict the battery internal resistance obtained from hybrid pulse power characterization (HPPC) tests to within 20 percent, making it suitable for low to medium fidelity powertrain design purposes. In total, this simple battery model can be employed as a real-time model in electrified vehicle battery management systems

  13. PSOC test of battery for photovoltaic systems; Taiyoko hatsuden yo chikudenchi no PSOC shiken

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, I.; Kato, K.; Takano, K.; Nozaki, K.; Sakuta, K. [Electrotechnical Laboratory, Tsukuba (Japan)

    1998-12-05

    Batteries at PV systems are ordinarily used under the PSOC (partial state of charge) condition. The use of to batteries under the PSOC condition influences the lifetime of the batteries. In order to clarify the influence of the PSOC, the PSOC test are carried out under the 3 stage temperature and 3 stage SOC (state of charge) conditions. In this paper is described the fast cycle results. (author)

  14. Battery Test Manual For Plug-In Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey R. Belt

    2010-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the procedures and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.

  15. Battery Test Manual For Plug-In Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey R. Belt

    2010-12-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the procedures and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.

  16. GIRAFFE test results summary

    Energy Technology Data Exchange (ETDEWEB)

    Yokobori, S.; Arai, K.; Oikawa, H. [Toshiba Corporation, Kawasaki (Japan)

    1996-03-01

    A passive system can provide engineered safety features enhancing safety system reliability and plant simplicity. Toshiba has conducted the test Program to demonstrate the feasibility of the SBWR passive safety system using a full-height, integral system test facility GIRAFFE. The test facility GIRAFFE models the SBWR in full height to correctly present the gravity driving head forces with a 1/400 volume scale. The GIRAFFE test Program includes the certification tests of the passive containment cooling system (PCCS) to remove the post-accident decay heat and the gravity driven cooling system (GDCS) to replenish the reactor coolant inventory during a LOCA. The test results have confirmed the PCCS and GDCS design and in addition, have demonstrated the operation of the pCCS with the presence of a lighter-than-steam noncondensable as well as with the presence of a heavier-than-steam, noncondensable. The GIRAFFE test Program has also provided the database to qualify a best estimate thermal-hydraulic computer code TRAC. The post test analysis results have shown that TRAC can accurately predict the PCCS heat removal Performance and the containment pressure response to a LOCA. This paper summarizes the GIRAFFE test results to investigate post-LOCA PCCS heat removal performance and post-test analysis using TRAC.

  17. The Ball Aptitude Battery (Test Review).

    Science.gov (United States)

    Hall, Alfred E.

    1985-01-01

    The 12 subtests of the Ball Aptitude Battery (BAB) listed in the administration manual were described. The reviewer believes this aptitude battery, designed for use with high school students and adults in job selection and placement, needs major improvements. It is suggested that the BAB be used solely for research purposes. (DWH)

  18. Batteries for Electric Vehicles

    Science.gov (United States)

    Conover, R. A.

    1985-01-01

    Report summarizes results of test on "near-term" electrochemical batteries - (batteries approaching commercial production). Nickel/iron, nickel/zinc, and advanced lead/acid batteries included in tests and compared with conventional lead/acid batteries. Batteries operated in electric vehicles at constant speed and repetitive schedule of accerlerating, coasting, and braking.

  19. Ibis DDT test results

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This document contains test results from a study done to determine the organochlorine levels in the livers of white-faced ibis from Stillwater Wildlife Management...

  20. Implications of NiMH Hysteresis on HEV Battery Testing and Performance

    Energy Technology Data Exchange (ETDEWEB)

    Motloch, Chester George; Belt, Jeffrey R; Hunt, Gary Lynn; Ashton, Clair Kirkendall; Murphy, Timothy Collins; Miller, Ted J.; Coates, Calvin; Tataria, H. S.; Lucas, Glenn E.; Duong, T.Q.; Barnes, J.A.; Sutula, Raymond

    2002-08-01

    Nickel Metal-Hydride (NiMH) is an advanced high-power battery technology that is presently employed in Hybrid Electric Vehicles (HEVs) and is one of several technologies undergoing continuing research and development by FreedomCAR. Unlike some other HEV battery technologies, NiMH exhibits a strong hysteresis effect upon charge and discharge. This hysteresis has a profound impact on the ability to monitor state-of-charge and battery performance. Researchers at the Idaho National Engineering and Environmental Laboratory (INEEL) have been investigating the implications of NiMH hysteresis on HEV battery testing and performance. Experimental results, insights, and recommendations are presented.

  1. Factor structure of intelligence test battery KOG9

    Directory of Open Access Journals (Sweden)

    Lazarević Ljiljana B.

    2008-01-01

    Full Text Available Authors of Cybernetic model of cognitive functioning designed a battery of tests (KOG9, based on the model in order to assess cognitive efficiency. Authors assert that scale's factor structure comprises the three factors: perceptive, serial and parallel processing. Results of the previous research as well as the logical analysis of the origin and content of the tests suggested the possibility that more parsimonious two-factor solution can explain the structure of the correlations among them equally well. KOG9 battery was administered to 1116 students of Faculty of sport and physical education and students from Department of Psychology in order to study its latent structure. In spite of the fact that factor congruence analyses suggested higher robustness (cross-sample stability of the two-factor solution, results of both EFA and CFA spoke in favor of the three-factor solution. The problem of the lack of stability of the three-factor solution was located in not particularly well targeted choice of the markers of the efficacy of perceptual processing. The suggestion is to preserve the calculation of all three group scores, with some corrections. First of all, tests CF2 and/or GT7 should be replaced by some other perceptual test/tests of lower cognitive complexity. Some of the tests tapping parallel processing should be replaced by those more in line with the logic of the model.

  2. Development and Testing of an UltraBattery-Equipped Honda Civic Hybrid

    Energy Technology Data Exchange (ETDEWEB)

    Sally (Xiaolei) Sun; Tyler Gray; Pattie Hovorka; Jeffrey Wishart; Donald Karner; James Francfort

    2012-08-01

    standard lead-acid unit experienced significant degradation after only 6,273 cycles. The high-carbon, ALABC battery manufactured in Project C3 also was tested under the advanced HEV schedule. Its performance was significantly better than the standard lead-acid unit, but was still inferior compared with the UltraBattery. The batteries supplied by Exide as part of the C3 Project performed well under the HEV screening test, especially at high temperatures. The results suggest that higher operating temperatures may improve the performance of lead-acid-based technologies operated under HEV conditions—it is recommended that life studies be conducted on these technologies under such conditions.

  3. Fairness in Employment Testing: Validity Generalization, Minority Issues, and the General Aptitude Test Battery. Book Review.

    Science.gov (United States)

    Levin, Henry M.

    1991-01-01

    This book reports results of a National Research Council study and the validity of generalizing from its studies of about 500 occupations to over 12,000 jobs. The use of the General Aptitude Test Battery for prediction is discussed, and its impact and recommendations for future use are considered. (SLD)

  4. Creasable Batteries: Understanding Failure Modes through Dynamic Electrochemical Mechanical Testing.

    Science.gov (United States)

    Blake, Aaron J; Kohlmeyer, Ryan R; Drummy, Lawrence F; Gutiérrez-Kolar, Jacob S; Carpena-Núñez, Jennifer; Maruyama, Benji; Shahbazian-Yassar, Reza; Huang, Hong; Durstock, Michael F

    2016-03-01

    Thin-film batteries that can be folded, bent, and even repeatedly creased with minimal or no loss in electrochemical performance have been demonstrated and systematically evaluated using two dynamic mechanical testing approaches for either controlled bending or creasing of flexible devices. The results show that mechanically robust and flexible Li-ion batteries (Li4Ti5O12//LiFePO4) based on the use of a nonwoven multiwalled carbon nanotube (MWNT) mat as a current collector (CC) exhibited a 14-fold decrease in voltage fluctuation at a bending strain of 4.2%, as compared to cells using traditional metal foil CCs. More importantly, MWNT-based full-cells exhibited excellent mechanical integrity through 288 crease cycles, whereas the foil full-cell exhibited continuously degraded performance with each fold and catastrophic fracture after only 94 folds. The enhancements due to MWNT CCs can be attributed to excellent interfacial properties as well as high mechanical strength coupled with compliancy, which allow the batteries to easily conform during mechanical abuse. These results quantitatively demonstrate the substantial enhancement offered in both mechanical and electrochemical stability which can be realized with traditional processing approaches when an appropriate choice of a flexible and robust CC is utilized. PMID:26741734

  5. Nickel hydrogen battery cell storage matrix test

    Science.gov (United States)

    Wheeler, James R.; Dodson, Gary W.

    1993-01-01

    Test were conducted to evaluate post storage performance of nickel hydrogen cells with various design variables, the most significant being nickel precharge versus hydrogen precharge. Test procedures and results are presented in outline and graphic form.

  6. Methods testing electrodes for advanced batteries

    Czech Academy of Sciences Publication Activity Database

    Novák, V.; Vondrák, Jiří

    Vol. 2. Brno: Akademické nakladatelství CERM, 2000 - (Vondrák, J.; Sedlaříková, M.), s. 13.1-13.4 ISBN 80-214-1615-7. [Advanced Batteries and Accumulators /1./. Brno (CZ), 28.08.2000-01.09.2000] R&D Projects: GA AV ČR IAA4032002 Institutional research plan: CEZ:AV0Z4032918 Keywords : electrodes * batteries * electrochemistry Subject RIV: CG - Electrochemistry

  7. Factorial Structure of Cognitive Activity Using a Neuropsychological Test Battery

    Directory of Open Access Journals (Sweden)

    A. Ardila

    1994-01-01

    Full Text Available A general neuropsychological test battery was assembled and individually given to a 98-subject sample, aged 11–12 years old. The battery included some basic and common tests routinely used in the evaluation of language, memory, spatial abilities, concept formation, and praxic abilities. Twenty-five different scores were calculated. A factor analysis with varimax rotation disclosed nine different factors, accounting for about 70% of the variance. Factor I was measured by a Sequential Verbal Memory test and Verbal Fluency subtests (“verbal factor”. Factor II was measured by the Wechsler Memory Scale Visual Memory subtests (immediate and delayed reproduction, and the Rey-Osterrieth Complex Figure (copy and immediate reproduction (“non-verbal memory and constructional factor”. Factor III was measured by the WMS Logical Memory subtests (immediate and delayed; “verbal memory factor”. Factor IV was associated with fine movements (tapping subtests, right and left hand; “fine movements factor”. Factor V was specially measured by the Information subtest of the WMS and the Boston Naming Test (“verbal knowledge”. Factor VI represented a “praxic ability factor” (ideomotor praxis tests. Delayed Associative Learning subtest measured Factor VII; and Digits measured Factor VIII. Factor IX was a “mental control factor” (Mental Control subtest of the Wechsler Memory Scale. The implications of these results to theories relating to the structure of cognitive activity are discussed.

  8. Results of electric-vehicle propulsion system performance on three lead-acid battery systems

    Science.gov (United States)

    Ewashinka, J. G.

    1984-01-01

    Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

  9. Climax granite test results

    International Nuclear Information System (INIS)

    The Lawrence Livermore Laboratory (LLL), as part of the Nevada Nuclear Waste Storage Investigations (NNWSI) program, is carrying out in situ rock mechanics testing in the Climax granitic stock at the Nevada Test Site (NTS). This summary addresses only those field data taken to date that address thermomechanical modeling for a hard-rock repository. The results to be discussed include thermal measurements in a heater test that was conducted from October 1977 through July 1978, and stress and displacement measurements made during and after excavation of the canister storage drift for the Spent Fuel Test (SFT) in the Climax granite. Associated laboratory and field measurements are summarized. The rock temperature for a given applied heat load at a point in time and space can be adequately modeled with simple analytic calculations involving superposition and integration of numerous point source solutions. The input, for locations beyond about a meter from the source, can be a constant thermal conductivity and diffusivity. The value of thermal conductivity required to match the field data is as much as 25% different from laboratory-measured values. Therefore, unless we come to understand the mechanisms for this difference, a simple in situ test will be required to obtain a value for final repository design. Some sensitivity calculations have shown that the temperature field is about ten times more sensitive to conductivity than to diffusivity under the test conditions.The orthogonal array was designed to detect anisotropy. After considering all error sources, anisotropic efforts in the thermal field were less than 5 to 10%

  10. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    Energy Technology Data Exchange (ETDEWEB)

    Schaeck, S.; Stoermer, A.O. [BMW Group, 80788 Muenchen (Germany); Albers, J. [Johnson Controls Power Solutions EMEA, 30419 Hannover (Germany); Weirather-Koestner, D. [ZSW Ulm, 89081 Ulm (Germany); Kabza, H. [Universitaet Ulm, Institut fuer Energiewandlung und -speicherung, 89081 Ulm (Germany)

    2011-02-01

    In the first part of this work selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already. (author)

  11. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    Science.gov (United States)

    Schaeck, S.; Stoermer, A. O.; Albers, J.; Weirather-Koestner, D.; Kabza, H.

    In the first part of this work [1] selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. [1,6]. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already.

  12. A differential approach to microcomputer test battery development and implementation

    Science.gov (United States)

    Kennedy, R. S.; Baltzley, D. R.; Osteen, M. K.; Turnage, J. J.

    1988-01-01

    The present microcomputer-based performance test battery emphasizes psychometric theory and utility for repeated-measures applications during extended exposure to various environmental stressors. In the menu that has been defined at the current state of this system's development, there are more than 30 'qualified' mental tests which stabilize in less than 10 min and possess test-retest reliabilities greater than 0.7 for a three-minute test/work period. The battery encompasses tests of cognition, information processing, psychomotor skill, memory, mood, etc. Several of the tests have demonstrated sensitivity to chemoradiotherapy, sleep loss, hypoxia, amphetamines, thermal stress, sensory deprivation, altitude, fatigue, and alcohol use. Recommendations are presented for 6-, 12-, and 22-min batteries.

  13. A test battery measuring auditory capabilities of listening panels

    DEFF Research Database (Denmark)

    Ghani, Jody; Ellermeier, Wolfgang; Zimmer, Karin

    2005-01-01

    battery of tests covering a larger range of auditory capabilities in order to assess individual listeners. The format of all tests is kept as 'objective' as possible by using a three-alternative forced-choice paradigm in which the subject must choose which of the sound samples is different, thus keeping...... the instruction to the subjects simple and common for all tests. Both basic (e.g. frequency discrimination) and complex (e.g. profile analysis) psychoacoustic tests are covered in the battery and a threshold of discrimination or detection is obtained for each test. Data were collected on 24 listeners...... who had been recruited for participation in an expert listening panel for evaluating the sound quality of hi-fi audio systems. The test battery data were related to the actual performance of the listeners when judging the degradation in quality produced by audio codecs....

  14. Galileo battery testing and the impact of test automation

    Science.gov (United States)

    Pertuch, W. T.; Dils, C. T.

    1985-01-01

    Test complexity, changes of test specifications, and the demand for tight control of tests led to the development of automated testing used for Galileo and other projects. The use of standardized interfacing, i.e., IEEE-488, with desktop computers and test instruments, resulted in greater reliability, repeatability, and accuracy of both control and data reporting. Increased flexibility of test programming has reduced costs by permitting a wide spectrum of test requirements at one station rather than many stations.

  15. Evaluation of a new charge algorithm for a lead-acid battery with gelled electrolyte using a 96V gel cell 4 as a test battery

    Science.gov (United States)

    Nowak, Dieter K.

    1989-10-01

    A summary is reported of test results obtained utilizing the new UAH charge algorithm for Lead-Acid batteries with gelled electrolyte. The battery performance data for a 96V Phase 4 Gel/Cell battery pack was tested in a Jet Industries Electrica vehicle. It was shown that the new charge concept is sound although there can be problems with batteries that are highly imbalanced and where excessive electronic noise is experienced on the electronic signal feed-back line that carries the voltage sensor signals from the battery. Additional work is needed to add intelligence to the charge algorithm in terms of a better ability to extract the beginning of gas development from the voltage spread function. This can probably be accomplished by scanning the voltages more often and including that data into the function analysis by adding software filters. The Phase 4 Gel/Cell battery performance was found to be about 20 percent lower than that of the Phase 3 Gel/Cell battery. Problems with cell valve leakage were encountered in the Phase 4 Gel/Cell that pose a threat to battery life although so far no battery module has been lost.

  16. Novel Field Test Equipment for Lithium-Ion Batteries in Hybrid Electrical Vehicle Applications

    OpenAIRE

    Goran Lindbergh; Olle Gelin; Pontus Svens; Marten Behm; Johan Lindstrom

    2011-01-01

    Lifetime testing of batteries for hybrid-electrical vehicles (HEV) is usually performed in the lab, either at the cell, module or battery pack level. Complementary field tests of battery packs in vehicles are also often performed. There are, however, difficulties related to field testing of battery-packs. Some examples are cost issues and the complexity of continuously collecting battery performance data, such as capacity fade and impedance increase. In this paper, a novel field test equipmen...

  17. Characterization testing of a 40 ampere hour bipolar nickel-hydrogen battery

    Science.gov (United States)

    Brewer, Jeffrey C.; Manzo, Michelle A.; Gemeiner, Russel P.

    1990-01-01

    Extensive characterization testing has been done on a second 40-ampere hour (A h), 10-cell, bipolar nickel-hydrogen (Ni-H2) battery, to study the effects of operating parameters such as charge and discharge rates, temperature, and pressure on capacity, A h and watt hour (W h) efficiencies, and end-of-charge and midpoint discharge voltages. Testing to date has produced many interesting results, with the battery performing well throughout the test matrix except during the high-rate (5 C and 10 C) discharges, where poorer than expected results were observed. The exact cause of this poor performance is, as yet, unknown. Small scale 2 in. x 2 in. battery tests are to be used in studying this problem. Low earth orbit cycle life testing at a 40-percent depth of discharge and 10 C is scheduled to follow the characterization testing.

  18. Study of the fire behavior of high-energy lithium-ion batteries with full-scale burning test

    Science.gov (United States)

    Ping, Ping; Wang, QingSong; Huang, PeiFeng; Li, Ke; Sun, JinHua; Kong, DePeng; Chen, ChunHua

    2015-07-01

    A full-scale burning test is conducted to evaluate the safety of large-size and high-energy 50 Ah lithium-iron phosphate/graphite battery pack, which is composed of five 10 Ah single cells. The complex fire hazards associated with the combustion process of the battery are presented. The battery combustion behavior can be summarized into the following stages: battery expansion, jet flame, stable combustion, a second cycle of a jet flame followed by stable combustion, a third cycle of a jet flame followed by stable combustion, abatement and extinguishment. The multiple jets of flame indicate serious consequences for the battery and pose a challenge for battery safety. The battery ignites when the battery temperature reaches approximately 175-180 °C. This critical temperature is related to an internal short circuit of the battery, which results from the melting of the separator. The maximum temperature of the flame can reach 1500 °C. The heat release rate (HRR) varies based on the oxygen generated by the battery and the Joule effect of the internal short circuit. The HRR and heat of combustion can reach 49.4 kW and 18,195.1 kJ, respectively. The state of charge of the battery has a significant effect on the maximum HRR, the overall heat generation and the mass loss of the battery.

  19. Battery Technology Life Verification Test Manual Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen

    2012-12-01

    The purpose of this Technology Life Verification Test (TLVT) Manual is to help guide developers in their effort to successfully commercialize advanced energy storage devices such as battery and ultracapacitor technologies. The experimental design and data analysis discussed herein are focused on automotive applications based on the United States Advanced Battery Consortium (USABC) electric vehicle, hybrid electric vehicle, and plug-in hybrid electric vehicle (EV, HEV, and PHEV, respectively) performance targets. However, the methodology can be equally applied to other applications as well. This manual supersedes the February 2005 version of the TLVT Manual (Reference 1). It includes criteria for statistically-based life test matrix designs as well as requirements for test data analysis and reporting. Calendar life modeling and estimation techniques, including a user’s guide to the corresponding software tool is now provided in the Battery Life Estimator (BLE) Manual (Reference 2).

  20. Battery Test Manual For Electric Vehicles, Revision 3

    Energy Technology Data Exchange (ETDEWEB)

    Christophersen, Jon P. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Electric Vehicles (EV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for EVs. However, it does share some methods described in the previously published battery test manual for plug-in hybrid electric vehicles. Due to the complexity of some of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Chul Bae of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).

  1. Exploratory battery technology development and testing report for 1989

    Energy Technology Data Exchange (ETDEWEB)

    Magnani, N.J.; Diegle, R.B.; Braithwaite, J.W.; Bush, D.M.; Freese, J.M.; Akhil, A.A.; Lott, S.E.

    1990-12-01

    Sandia National Laboratories, Albuquerque, has been designated as Lead Center for the Exploratory Battery Technology Development and Testing Project, which is sponsored by the US Department of Energy's Office of Energy Storage and Distribution. In this capacity, Sandia is responsible for the engineering development of advanced rechargeable batteries for both mobile and stationary energy storage applications. This report details the technical achievements realized in pursuit of the Lead Center's goals during calendar year 1989. 4 refs., 84 figs., 18 tabs.

  2. Bidirectional converter interface for a battery energy storage test bench

    DEFF Research Database (Denmark)

    Trintis, Ionut; Thomas, Stephan; Blank, Tobias;

    2011-01-01

    This paper presents the bidirectional converter interface for a 6 kV battery energy storage test bench. The power electronic interface consists a two stage converter topology having a low voltage dc-ac grid connected converter and a new dual active bridge dc-dc converter with high transformation...... ratio. The dc-dc converter controls the battery charge/discharge current while the grid converter controls the common dc-link voltage and the grid current. The applied control structures and the hardware implementation of both converters are presented, together with their interaction. Experimental...

  3. Space Technology-5 Lithium-Ion Battery Design, Qualification and Integration and Testing

    Science.gov (United States)

    Rao, Gopalakishna M.; Stewart, Karen; Ameen, Syed; Banfield, Peter K.

    2005-01-01

    This document is a viewgraph presentation that reviews the Lithium Ion Battery for the Space Technology-5 (ST-5) mission. Included in the document is a review of the ST-5 Mission, a review of the battery requirements, a description of the battery and the battery materials. The testing and the integration and qualification data is reviewed.

  4. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  5. Organic Separation Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Rinehart, Donald E.; Peterson, Reid A.

    2014-09-22

    Separable organics have been defined as “those organic compounds of very limited solubility in the bulk waste and that can form a separate liquid phase or layer” (Smalley and Nguyen 2013), and result from three main solvent extraction processes: U Plant Uranium Recovery Process, B Plant Waste Fractionation Process, and Plutonium Uranium Extraction (PUREX) Process. The primary organic solvents associated with tank solids are TBP, D2EHPA, and NPH. There is concern that, while this organic material is bound to the sludge particles as it is stored in the tanks, waste feed delivery activities, specifically transfer pump and mixer pump operations, could cause the organics to form a separated layer in the tank farms feed tank. Therefore, Washington River Protection Solutions (WRPS) is experimentally evaluating the potential of organic solvents separating from the tank solids (sludge) during waste feed delivery activities, specifically the waste mixing and transfer processes. Given the Hanford Tank Waste Treatment and Immobilization Plant (WTP) waste acceptance criteria per the Waste Feed Acceptance Criteria document (24590-WTP-RPT-MGT-11-014) that there is to be “no visible layer” of separable organics in the waste feed, this would result in the batch being unacceptable to transfer to WTP. This study is of particular importance to WRPS because of these WTP requirements.

  6. Evaluation and Test of a Battery Management Unit for Hybrid Electric Vehicles

    OpenAIRE

    Nejedly, Andreas

    2011-01-01

    In this thesis, the functions of a Battery Management Unit developed in house by Volvo Technology will be tested and evaluated in different aspects. The battery management system tested is a Kalman filter which uses measured cell voltage and current measurements to estimate the state of charge online. The system was tested against a Simulink model of a battery to verify its function in different conditions, and later on, the estimator was tested online with a battery pack consisting of 14 Li-...

  7. Accelerated lifetime testing methodology for lifetime estimation of Lithium-ion batteries used in augmented wind power plants

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Swierczynski, Maciej Jozef; Stan, Ana-Irina;

    2013-01-01

    The development of lifetime estimation models for Lithium-ion battery cells, which are working under highly variable mission profiles characteristic for wind power plant applications, requires a lot of expenditures and time resources. Therefore, batteries have to be tested under accelerated...... lifetime ageing conditions. This paper presents a three-stage methodology used for accelerated lifetime testing of Lithium-ion batteries. The results obtained at the end of the accelerated ageing process can be used for the parametrization of a performance-degradation lifetime model. In the proposed...... methodology both calendar and cycling lifetime tests are considered since both components are influencing the lifetime of Lithium-ion batteries. The methodology proposes also a lifetime model verification stage, where Lithium-ion battery cells are tested at normal operating conditions using an application...

  8. Results and comparison of seven accelerated cycling test procedures for the photovoltaic application

    Science.gov (United States)

    Potteau, E.; Desmettre, D.; Mattera, F.; Bach, O.; Martin, J.-L.; Malbranche, P.

    Choosing the right battery for a given photovoltaic (PV) system is a key question, because it strongly influences the cost and reliability of the system. This paper presents results of seven test procedures experienced at the GENEC battery test facility. A set of four complementary tests is selected, covering the various types of photovoltaic systems. Moreover, the analysis of these results gives an estimation of the ageing rate for the different types of batteries used in photovoltaic systems.

  9. 75 FR 16957 - Energy Conservation Program: Test Procedures for Battery Chargers and External Power Supplies

    Science.gov (United States)

    2010-04-02

    ... Framework Document for Battery Chargers and External Power Supplies on June 4, 2009. 74 FR 26816. DOE then... Test Procedure B. Review of Battery Charger and External Power Supply Standby Mode and Off Mode Test...) Battery Preparation (e) Reversed Testing Order (f) End of Discharge for Other Chemistries C. Review...

  10. CCTF CORE I test results

    International Nuclear Information System (INIS)

    This report presents the results of the following CCTF CORE I tests conducted in FY. 1980. (1) Multi-dimensional effect test, (2) Evaluation model test, (3) FLECHT coupling test. On the first test, one-dimensional treatment of the core thermohydrodynamics was discussed. On the second and third tests, the test results were compared with the results calculated by the evaluation model codes and the results of the corresponding FLECHT-SET test (Run 2714B), respectively. The work was performed under contracts with the Atomic Energy Bureau of Science and Technology Agency of Japan. (author)

  11. The testing of batteries linked to supercapacitors with electrochemical impedance spectroscopy: A comparison between Li-ion and valve regulated lead acid batteries

    Science.gov (United States)

    Ferg, Ernst; Rossouw, Claire; Loyson, Peter

    2013-03-01

    For electric vehicles, a supercapacitor can be coupled to the electrical system in order to increase and optimize the energy and power densities of the drive system during acceleration and regenerative breaking. This study looked at the charge acceptance and maximum discharge ability of a valve regulated lead acid (VRLA) and a Li-ion battery connected in parallel to supercapacitors. The test procedure evaluated the advantage of using a supercapacitor at a 2 F:1 Ah ratio with the battery types at various states of charge (SoC). The results showed that about 7% of extra charge was achieved over a 5-s test time for a Li-ion hybrid system at 20% SoC, whereas at the 80% SoC the additional capacity was approximately 16%. While for the VRLA battery hybrid system, an additional charge of up to 20% was achieved when the battery was at 80% SoC, with little or no benefit at the 20% SoC. The advantage of the supercapacitor in parallel with a VRLA battery was noticeable on its discharge ability, where significant extra capacity was achieved for short periods of time for a battery at the 60% and 40% SoC when compared to the Li-ion hybrid system. The study also made use of Electrochemical Impedance Spectroscopy (EIS) with a suitable equivalent circuit model to explain, in particular, the internal resistance and capacitance differences observed between the different battery chemistries with and without a supercapacitor.

  12. Accelerated Lifetime Testing Methodology for Lifetime Estimation of Lithium-ion Batteries used in Augmented Wind Power Plants

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Swierczynski, Maciej Jozef; Stan, Ana-Irina;

    2014-01-01

    The development of lifetime estimation models for Lithium-ion battery cells, which are working under highly variable mission profiles characteristic for wind power plant applications, requires a lot of expenditures and time resources. Therefore, batteries have to be tested under accelerated...... lifetime ageing conditions. This paper presents a three-stage methodology used for accelerated lifetime testing of Lithium ion batteries. The results obtained at the end of the accelerated ageing process were used for the parametrization of a performance-degradation lifetime model, which is able to predict...... both the capacity fade and the power capability decrease of the selected Lithium-ion battery cells. In the proposed methodology both calendar and cycling lifetime tests were considered since both components are influencing the lifetime of Lithium-ion batteries. Furthermore, the proposed methodology was...

  13. MER ARA pyroshock test results

    Science.gov (United States)

    Chang, Kurng Y.

    2004-01-01

    This paper presents the shock test results achieved in the MER ARA/brush motor pyroshock qualification. The results of MER flight system pyrofiring tests in comparison with the ARA shock test requirements are discussed herein. Alternate test methods were developed in an effort to qualify the critical MER equipment for adequate performance in the actual flight pyroshock condition.

  14. Design and Construction of a Test Bench to Characterize Efficiency and Reliability of High Voltage Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Blank, Tobias; Thomas, Stephan; Roggendorf, Christoph;

    2010-01-01

    was built to analyze these processes for different battery technologies. A special safety infrastructure for the test bench was developed due to the high voltage and the storable energy of approximately 120 kWh. This paper presents the layout of the test bench for analyzing high voltage batteries with...... about 4,300 volts including all components, the safety requirements with the resultant safety circuit and the aim of the investigations to be performed with the test bench....

  15. A cost effective battery bank for I(sup 2)T testing and evaluation of electrical switchgear

    Science.gov (United States)

    Reass, W. A.

    The electrical design and mechanical construction of a 50 kA step switched battery bank. Individual fuses protect each of the forty parallel isolated strings of three series (12 V) batteries. Step current waveforms of 12.5 kA, 25 kA, 37.5 kA, and 50 kA are produced by 8 sets of pneumatically driven 20 pole step switches and current limiting stainless steel trombone resistors. Inexpensive, yet conservatively designed, Group 65 Motorcraft car batteries are used to give an I(sup 2)t capability of better than 5 x 10(exp 9). The battery bank has well over 1500 shots, with testing of commercial switchgear continuing. In addition to the battery bank engineering data, results of repetitive testing of vacuum interrupters at their I(sup 2)t limit will be provided.

  16. Battery of behavioral tests in mice to study postoperative delirium.

    Science.gov (United States)

    Peng, Mian; Zhang, Ce; Dong, Yuanlin; Zhang, Yiying; Nakazawa, Harumasa; Kaneki, Masao; Zheng, Hui; Shen, Yuan; Marcantonio, Edward R; Xie, Zhongcong

    2016-01-01

    Postoperative delirium is associated with increased morbidity, mortality and cost. However, its neuropathogenesis remains largely unknown, partially owing to lack of animal model(s). We therefore set out to employ a battery of behavior tests, including natural and learned behavior, in mice to determine the effects of laparotomy under isoflurane anesthesia (Anesthesia/Surgery) on these behaviors. The mice were tested at 24 hours before and at 6, 9 and 24 hours after the Anesthesia/Surgery. Composite Z scores were calculated. Cyclosporine A, an inhibitor of mitochondria permeability transient pore, was used to determine potential mitochondria-associated mechanisms of these behavioral changes. Anesthesia/Surgery selectively impaired behaviors, including latency to eat food in buried food test, freezing time and time spent in the center in open field test, and entries and duration in the novel arm of Y maze test, with acute onset and various timecourse. The composite Z scores quantitatively demonstrated the Anesthesia/Surgery-induced behavior impairment in mice. Cyclosporine A selectively ameliorated the Anesthesia/Surgery-induced reduction in ATP levels, the increases in latency to eat food, and the decreases in entries in the novel arm. These findings suggest that we could use a battery of behavior tests to establish a mouse model to study postoperative delirium. PMID:27435513

  17. The UC Davis Emerging Lithium Battery Test Project

    OpenAIRE

    Burke, Andy; Miller, Marshall

    2009-01-01

    This report is concerned with the testing and evaluation of various battery chemistries for use in PHEVs. Test data are presented for lithium-ion cells and modules utilizing nickel cobalt, iron phosphate, and lithium titanate oxide in the electrodes. Cells with NiCoO2 (nickelate) in the positive electrode have the highest energy density being in the range of 100-170 Wh/kg. Cells using iron phosphate in the positive have energy density between 80-110 Wh/kg and those using lithium titanate oxid...

  18. Requirements for Defining Utility Drive Cycles: An Exploratory Analysis of Grid Frequency Regulation Data for Establishing Battery Performance Testing Standards

    Energy Technology Data Exchange (ETDEWEB)

    Hafen, Ryan P.; Vishwanathan, Vilanyur V.; Subbarao, Krishnappa; Kintner-Meyer, Michael CW

    2011-10-19

    Battery testing procedures are important for understanding battery performance, including degradation over the life of the battery. Standards are important to provide clear rules and uniformity to an industry. The work described in this report addresses the need for standard battery testing procedures that reflect real-world applications of energy storage systems to provide regulation services to grid operators. This work was motivated by the need to develop Vehicle-to-Grid (V2G) testing procedures, or V2G drive cycles. Likewise, the stationary energy storage community is equally interested in standardized testing protocols that reflect real-world grid applications for providing regulation services. As the first of several steps toward standardizing battery testing cycles, this work focused on a statistical analysis of frequency regulation signals from the Pennsylvania-New Jersey-Maryland Interconnect with the goal to identify patterns in the regulation signal that would be representative of the entire signal as a typical regulation data set. Results from an extensive time-series analysis are discussed, and the results are explained from both the statistical and the battery-testing perspectives. The results then are interpreted in the context of defining a small set of V2G drive cycles for standardization, offering some recommendations for the next steps toward standardizing testing protocols.

  19. Development of a standardized battery of performance tests for the assessment of noise stress effects

    Science.gov (United States)

    Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.

    1973-01-01

    A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

  20. Unexpected Type of Failure of Thermal Battery Resulting in a Near Miss to a Serious Injury

    Energy Technology Data Exchange (ETDEWEB)

    Richter, Daena Kei [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-01

    On 6/26/2015 at 1445 in 894/136, a thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following a routine test where the battery is activated. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another containment box within the same room; initial indications are that the battery package ruptured after it went into thermal runaway which led to the operator receiving bruising to the palm of the hand from the pressure of the expulsion. The operator was wearing the prescribed PPE, which was safety glasses and a high temperature glove on the hand that was holding the battery.

  1. Personnel Test Battery and Scoring Procedures. Memorandum No. L.S. 15.

    Science.gov (United States)

    Berson, Barry L.

    The purpose of this memo is to present tests that comprise the test battery used to select Navy personnel to train marine mammals, and to describe the scoring procedures of the tests. The test battery consists of: Biosystems General Information Test (BGIT), Personnel History Questionnaire (PHQ), Gordon Personal Inventory, Gordon Personal Profile,…

  2. 76 FR 31749 - Energy Conservation Program for Certain Consumer Appliances: Test Procedures for Battery Chargers...

    Science.gov (United States)

    2011-06-01

    ... procedure final rule (74 FR 13318 (March 27, 2009)), did not measure battery charger energy consumption in... time. 71 FR 71340, 71360. The battery charger active mode test procedure in today's final rule removes... definitions into appendices Y and Z. 74 FR 13318. In today's final rule, DOE amends the battery charger...

  3. MITG test procedure and results

    International Nuclear Information System (INIS)

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  4. Evaluating the RELM Test Results

    OpenAIRE

    Sachs, Michael K.; Ya-Ting Lee; Turcotte, Donald L.; Holliday, James R.; Rundle, John B.

    2012-01-01

    We consider implications of the Regional Earthquake Likelihood Models (RELM) test results with regard to earthquake forecasting. Prospective forecasts were solicited for M≥4.95 earthquakes in California during the period 2006–2010. During this period 31 earthquakes occurred in the test region with M≥4.95. We consider five forecasts that were submitted for the test. We compare the forecasts utilizing forecast verification methodology developed in the atmospheric sciences, specifically for torn...

  5. State Test Results Are Predictable

    Science.gov (United States)

    Tienken, Christopher H.

    2014-01-01

    Out-of-school, community demographic and family-level variables have an important influence on student achievement as measured by large-scale standardized tests. Studies described here demonstrated that about half of the test score is accounted for by variables outside the control of teachers and school administrators. The results from these…

  6. Building neurophenomics in zebrafish: Effects of prior testing stress and test batteries.

    Science.gov (United States)

    Song, Cai; Yang, Lei; Wang, JiaJia; Chen, Peirong; Li, Shaomin; Liu, Yingcong; Nguyen, Michael; Kaluyeva, Aleksandra; Kyzar, Evan J; Gaikwad, Siddharth; Kalueff, Allan V

    2016-09-15

    The zebrafish (Danio rerio) is a promising model organism for neurophenomics - a new field of neuroscience linking neural phenotypes to various genetic and environmental factors. However, the effects of prior experimental manipulations on zebrafish performance in different behavioral paradigms remain unclear. Here, we examine the influence of selected stressful procedures and test batteries on adult zebrafish anxiety-like behaviors in two commonly used models - the novel tank (NTT) and the light-dark box (LDB) tests. While no overt behavioral differences between outbred short-fin wild-type (WT) and mutant 'pink' glowfish were seen in both tests under baseline (control) conditions, an acute severe stressor (a 30-min car transportation) detected significantly lower mutant fish anxiety-like behavior in these tests. In contrast, WT zebrafish showed no overt NTT or LDB responses following a mild stressor (5-min 40-Wt light) exposure, also showing no differences in batteries of NTT and LDB run immediately one after another, or with a 1-day interval. Collectively, these findings suggest that zebrafish may be relatively less sensitive (e.g., than other popular species, such as rodents) to the test battery effect, and show that stronger stressors may be needed (to complement low-to-moderate stress aquatic screens) to better reveal phenotypical variance in zebrafish assays. Strengthening the value of zebrafish models in neurophenotyping research, this study indicates the potential of using more test batteries and a wider spectrum of pre-test stressors in zebrafish behavioral assays. PMID:27155502

  7. Engineering model cryocooler test results

    International Nuclear Information System (INIS)

    This paper reports that recent testing of diaphragm-defined, Stirling-cycle machines and components has demonstrated cooling performance potential, validated the design code, and confirmed several critical operating characteristics. A breadboard cryocooler was rebuilt and tested from cryogenic to near-ambient cold end temperatures. There was a significant increase in capacity at cryogenic temperatures and the performance results compared will with code predictions at all temperatures. Further testing on a breadboard diaphragm compressor validated the calculated requirement for a minimum axial clearance between diaphragms and mating heads

  8. FFTF status and test results

    International Nuclear Information System (INIS)

    A general description of the FFTF is presented concerning the construction progress; status of startup and selected startup test results; and planned experiment program during and subsequent to the startup testing program. The FFTF is a 400 MWt, sodium cooled test reactor plant consisting of a fast-neutron reactor fueled by mixed plutonium oxide-uranium oxide fuel elements, three independent heat transport loops, extensive instrumentation, fuel handling equipment, and auxiliary systems which support the main reactor and cooling systems. The FFTF contains no steam generators, electrical generating equipment, or breeding blankets. Heat generated in the reactor is released to the ambient atmosphere by twelve large sodium-to-air heat exchangers

  9. COLD TEST LOOP INTEGRATED TEST LOOP RESULTS

    International Nuclear Information System (INIS)

    A testing facility (Cold Test Loop) was constructed and operated to demonstrate the efficacy of the Accelerated Waste Retrieval (AWR) Project's planned sluicing approach to the remediation of Silos 1 and 2 at the Fernald Environmental Management Project near Cincinnati, Ohio. The two silos contain almost 10,000 tons of radium-bearing low-level waste, which consists primarily of solids of raffinates from processing performed on ores from the Democratic Republic of Congo (commonly referred to as ''Belgium Congo ores'') for the recovery of uranium. These silos are 80 ft in diameter, 36 ft high to the center of the dome, and 26.75 ft to the top of the vertical side walls. The test facility contained two test systems, each designed for a specific purpose. The first system, the Integrated Test Loop (ITL), a near-full-scale plant including the actual equipment to be installed at the Fernald Site, was designed to demonstrate the sluicing operation and confirm the selection of a slurry pump, the optimal sluicing nozzle operation, and the preliminary design material balance. The second system, the Component Test Loop (CTL), was designed to evaluate many of the key individual components of the waste retrieval system over an extended run. The major results of the initial testing performed during July and August 2002 confirmed that the AWR approach to sluicing was feasible. The ITL testing confirmed the following: (1) The selected slurry pump (Hazleton 3-20 type SHW) performed well and is suitable for AWR application. However, the pump's motor should be upgraded to a 200-hp model and be driven by a 150-hp variable-frequency drive (VFD). A 200-hp VFD is not much more expensive and would allow the pump to operate at full speed. (2) The best nozzle performance was achieved by using 15/16-in. nozzles operated alternately. This configuration appeared to most effectively mine the surrogate. (3) The Solartron densitometer, which was tested as an alternative mass flow measurement

  10. Mobile evaporator corrosion test results

    Energy Technology Data Exchange (ETDEWEB)

    Rozeveld, A.; Chamberlain, D.B.

    1997-05-01

    Laboratory corrosion tests were conducted on eight candidates to select a durable and cost-effective alloy for use in mobile evaporators to process radioactive waste solutions. Based on an extensive literature survey of corrosion data, three stainless steel alloys (304L, 316L, AL-6XN), four nickel-based alloys (825, 625, 690, G-30), and titanium were selected for testing. The corrosion tests included vapor phase, liquid junction (interface), liquid immersion, and crevice corrosion tests on plain and welded samples of candidate materials. Tests were conducted at 80{degrees}C for 45 days in two different test solutions: a nitric acid solution. to simulate evaporator conditions during the processing of the cesium ion-exchange eluant and a highly alkaline sodium hydroxide solution to simulate the composition of Tank 241-AW-101 during evaporation. All of the alloys exhibited excellent corrosion resistance in the alkaline test solution. Corrosion rates were very low and localized corrosion was not observed. Results from the nitric acid tests showed that only 316L stainless steel did not meet our performance criteria. The 316L welded interface and crevice specimens had rates of 22.2 mpy and 21.8 mpy, respectively, which exceeds the maximum corrosion rate of 20 mpy. The other welded samples had about the same corrosion resistance as the plain samples. None of the welded samples showed preferential weld or heat-affected zone (HAZ) attack. Vapor corrosion was negligible for all alloys. All of the alloys except 316L exhibited either {open_quotes}satisfactory{close_quotes} (2-20 mpy) or {open_quotes}excellent{close_quotes} (<2 mpy) corrosion resistance as defined by National Association of Corrosion Engineers. However, many of the alloys experienced intergranular corrosion in the nitric acid test solution, which could indicate a susceptibility to stress corrosion cracking (SCC) in this environment.

  11. Disclosure of stress test results

    OpenAIRE

    Berlin, Mitchell

    2015-01-01

    Should regulatory bank examinations be made public? Regulators have argued that the confidentiality of the examination process promotes frank exchanges between bankers and examiners and that public disclosure of examination results could have a chilling effect. I examine the tradeoffs in a world in which examination results can be kept confidential, but regulatory interventions are observable by market participants, as they typically are for stress tests. Inducing banks to communicate truthfu...

  12. Modified performance test of vented lead acid batteries for stationary applications

    International Nuclear Information System (INIS)

    The concept of a modified performance test for vented lead acid batteries in stationary applications has been developed by the IEEE Battery Working Group. The modified performance test is defined as a test in the ''as found'' condition of the battery capacity and its ability to provide a high rate, short duration load (usually the highest rate of the duty cycle) that will confirm the battery's ability to meet the critical period of the load duty cycle, in addition to determining its percentage of rated capacity. This paper will begin by reviewing performance and service test requirements and concerns associated with both types of tests. The paper will then discuss the rationale for developing a modified performance test along with the benefits that can be derived from performing a modified performance test in lieu of a capacity test and/or a service test. The paper will conclude with an example on how to apply a modified performance test and test acceptance criteria

  13. Evaluation of the Generalizability of the Number of Abnormal Scores and the Overall Test Battery Mean as Measures of Performance Validity to a Different Test Battery.

    Science.gov (United States)

    Silk-Eglit, Graham M; Miele, Andrea S; Stenclik, Jessica H; Lynch, Julie K; McCaffrey, Robert J

    2015-01-01

    Davis, Axelrod, McHugh, Hanks, and Millis (2013) documented that in a battery of 25 tests, producing 15, 10, and 5 abnormal scores at 1, 1.5, and 2 standard deviations below the norm-referenced mean, respectively, and an overall test battery mean (OTBM) of T ≤ 38 accurately identifies performance invalidity. However, generalizability of these findings to other samples and test batteries remains unclear. This study evaluated the use of abnormal scores and the OTBM as performance validity measures in a different sample that was administered a 25-test battery that minimally overlapped with Davis et al.'s test battery. Archival analysis of 48 examinees with mild traumatic brain injury seen for medico-legal purposes was conducted. Producing 18 or more, 7 or more, and 5 or more abnormal scores at 1, 1.5, and 2 standard deviations below the norm-referenced mean, respectively, and an OTBM of T ≤ 40 most accurately classified examinees; however, using Davis et al.'s proposed cutoffs in the current sample maintained specificity at or near acceptable levels. Due to convergence across studies, producing ≥5 abnormal scores at 2 standard deviations below the norm-referenced mean is the most appropriate cutoff for clinical implementation; however, for batteries consisting of a different quantity of tests than 25, an OTBM of T ≤ 38 is more appropriate. PMID:25785544

  14. Recent results from dispersant testing

    Energy Technology Data Exchange (ETDEWEB)

    Fingas, M.; Fieldhouse, B.; Wang, Z.; Sigouin, L.; Landriault, M. [Environment Canada, Ottawa, ON (Canada). Emergencies Science Div; Mullin, J.V. [Department of the Interior, Herndon, VA (United States). Minerals Management Service

    2000-07-01

    A number of small studies were conducted at Environment Canada on the topic of dispersants and their effectiveness. Dispersant analytical procedures were reviewed and modified when necessary. Testing of new products was also performed along with the testing of long-term stored dispersants. A comparative evaluation of Corexit 9500 and 9527 dispersant formulations showed major modifications to the quantity of dispersed oil, although the Swirling Flask Test did not undergo major modifications. This method used to rely on colorimetric analysis, but was upgraded to gas chromatographic analysis. This move from one method to the other brought on additional changes that had not been considered when the initial change in method was made. Some aspects of the analysis were then improved and corrected to rectify small deficiencies. The authors reported on the results concerning the testing of several new dispersants products. The comparative study between the formulations of Corexit 9500 and 9527 indicated that the effectiveness of 9500 was greater than 9527, but showed no relation to the amount of effectiveness. In terms of statistics, 9527 proved to be more effective than 9500, 25 per cent of the time. The test series conducted on Corexit 9527, stored 20 years in the tank of a truck, varied in effectiveness, toxicity, and colour but did not affect significantly the overall effectiveness of the product in the field. 10 refs., 4 tabs., 2 figs., 1 append.

  15. Design of a Test Bench for Battery Management

    OpenAIRE

    Dussarrat, Johann; Balondrade, Gael

    2012-01-01

    The report deals with energy conservation, mainly in the field of portable energy, which is asubject that today raises questions around the world. This report describes the design and theimplementation of a Battery Management System on the platform NI ELVIS II+ managed bythe software Labview. The first aim has been on finding information about the design of theBattery Management System that corresponds to the choice of the battery itself. The systemwas designed completely independent with dif...

  16. Development and testing of mechanically stable Vanadium redox flow battery

    OpenAIRE

    Molchanov, Bogdan

    2016-01-01

    This thesis work is concerned with electrochemical energy storage and conversion technology based on vanadium chemistry. This thesis is continuation of a work done at Arcada in summer 2015 and is expected to become a foundation for future research in the flow battery area. The major objective of this study was to build a prototype of vanadium flow battery that is robust enough to be analyzed and compared against flow batteries of other research groups. The work is broken down into four smalle...

  17. Evaluating the RELM Test Results

    Directory of Open Access Journals (Sweden)

    Michael K. Sachs

    2012-01-01

    Full Text Available We consider implications of the Regional Earthquake Likelihood Models (RELM test results with regard to earthquake forecasting. Prospective forecasts were solicited for M≥4.95 earthquakes in California during the period 2006–2010. During this period 31 earthquakes occurred in the test region with M≥4.95. We consider five forecasts that were submitted for the test. We compare the forecasts utilizing forecast verification methodology developed in the atmospheric sciences, specifically for tornadoes. We utilize a “skill score” based on the forecast scores λfi of occurrence of the test earthquakes. A perfect forecast would have λfi=1, and a random (no skill forecast would have λfi=2.86×10-3. The best forecasts (largest value of λfi for the 31 earthquakes had values of λfi=1.24×10-1 to λfi=5.49×10-3. The best mean forecast for all earthquakes was λ̅f=2.84×10-2. The best forecasts are about an order of magnitude better than random forecasts. We discuss the earthquakes, the forecasts, and alternative methods of evaluation of the performance of RELM forecasts. We also discuss the relative merits of alarm-based versus probability-based forecasts.

  18. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  19. Battery Usage and Thermal Performance of the Toyota Prius and Honda Insight for Various Chassis Dynamometer Test Procedures: Preprint

    International Nuclear Information System (INIS)

    This study describes the results from the National Renewable Energy Laboratory's (NREL) chassis dynamometer testing of a 2000 model year Honda Insight and 2001 model year Toyota Prius. The tests were conducted for the purpose of evaluating the battery thermal performance, assessing the impact of air conditioning on fuel economy and emissions, and providing information for NREL's Advanced Vehicle Simulator (ADVISOR)

  20. RSG Deployment Case Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Owsley, Stanley L.; Dodson, Michael G.; Hatchell, Brian K.; Seim, Thomas A.; Alexander, David L.; Hawthorne, Woodrow T.

    2005-09-01

    The RSG deployment case design is centered on taking the RSG system and producing a transport case that houses the RSG in a safe and controlled manner for transport. The transport case was driven by two conflicting constraints, first that the case be as light as possible, and second that it meet a stringent list of Military Specified requirements. The design team worked to extract every bit of weight from the design while striving to meet the rigorous Mil-Spec constraints. In the end compromises were made primarily on the specification side to control the overall weight of the transport case. This report outlines the case testing results.

  1. The NIH Toolbox Cognition Battery: Results from a Large Normative Developmental Sample (PING)

    Science.gov (United States)

    Akshoomoff, Natacha; Newman, Erik; Thompson, Wesley K.; McCabe, Connor; Bloss, Cinnamon S.; Chang, Linda; Amaral, David G.; Casey, B. J.; Ernst, Thomas M.; Frazier, Jean A.; Gruen, Jeffrey R.; Kaufmann, Walter E.; Kenet, Tal; Kennedy, David N.; Libiger, Ondrej; Mostofsky, Stewart; Murray, Sarah S.; Sowell, Elizabeth R.; Schork, Nicholas; Dale, Anders M.; Jernigan, Terry L.

    2014-01-01

    Objective The NIH Toolbox Cognition Battery (NTCB) was designed to provide a brief, efficient computerized test of key neuropsychological functions appropriate for use in children as young as 3 years of age. This report describes the performance of a large group of typically developing children and adolescents and examines the impact of age and sociocultural variables on test performance. Method The NTCB was administered to a sample of 1020 typically developing males and females ranging in age from 3 to 20 years, diverse in terms of socioeconomic status (SES) and race/ethnicity, as part of the new publicly accessible Pediatric Imaging, Neurocognition, and Genetics (PING) data resource, at 9 sites across the United States. Results General additive models of nonlinear age-functions were estimated from age-differences in test performance on the 8 NTCB subtests while controlling for family SES and genetic ancestry factors (GAFs). Age accounted for the majority of the variance across all NTCB scores, with additional significant contributions of gender on some measures, and of SES and race/ethnicity (GAFs) on all. After adjusting for age and gender, SES and GAFs explained a substantial proportion of the remaining unexplained variance in Picture Vocabulary scores. Conclusions The results highlight the sensitivity to developmental effects and efficiency of this new computerized assessment battery for neurodevelopmental research. Limitations are observed in the form of some ceiling effects in older children, some floor effects, particularly on executive function tests in the youngest participants, and evidence for variable measurement sensitivity to cultural/socioeconomic factors. PMID:24219608

  2. Developing a Test Battery to assess Determinants of Marital Relationship Satisfaction in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Nadia Al Tamimi

    2009-12-01

    Full Text Available A sample of 50 wives and 50 husbands from Saudi Arabia completed a battery of scales assessing different aspects of couple relationship functioning which had been translated from English to Arabic. The selection of measures was based on the Vulnerability-Stress-Adaptation Model (VSA, Karney & Bradbury, 1995 and included measures of partner attachment, conflict behaviour, and relationship with members of the family-in-law as predictors and marital satisfaction as criterion variable. All scales of the test battery showed acceptable reliability. The newly developed conflict behaviour scale consisted of three theoretically meaningful factors (Positive behaviour, Negative behaviour, and Abuse. All instruments showed evidence for convergent validity and contributed significantly to the prediction of relationship satisfaction. The results showed in general a similar pattern of correlations in Saudi Arabia as previous studies in Western countries.

  3. ENRtool - BesTest results

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne

    2007-01-01

    Test af beregninger gennemført med ENRtool over for BesTest valideringen under klimatiske forhold for Denver, Colorado.......Test af beregninger gennemført med ENRtool over for BesTest valideringen under klimatiske forhold for Denver, Colorado....

  4. Seismic-fragility tests of new and accelerated-aged Class 1E battery cells

    International Nuclear Information System (INIS)

    The seismic-fragility response of naturally-aged nuclear station safety-related batteries is of interest for two reasons: (1) to determine actual failure modes and thresholds and (2) to determine the validity of using the electrical capacity of individual cells as an indicator of the potential survivability of a battery given a seismic event. Prior reports in this series discussed the seismic-fragility tests and results for three specific naturally-aged cell types: 12-year old NCX-2250, 10-year old LCU-13, and 10-year old FHC-19. This report focuses on the complementary approach, namely, the seismic-fragility response of accelerated-aged batteries. Of particular interest is the degree to which such approaches accurately reproduce the actual failure modes and thresholds. In these tests the significant aging effects observed, in terms of seismic survivability, were: embrittlement of cell cases, positive bus material and positive plate grids; and excessive sulphation of positive plate active material causing hardening and expansion of positive plates. The IEEE Standard 535 accelerated aging method successfully reproduced seismically significant aging effects in new cells but accelerated grid embrittlement an estimated five years beyond the conditional age of other components

  5. Improvement of failure detection of production line test results by implementing Δ V criteria

    Science.gov (United States)

    Schröer, Tony; Niehren, Gerhard

    The reliability of automotive batteries is an important factor, especially for the OEM market. To ensure consistent reliability all automotive batteries are subjected to electrical load tests prior to shipment. These tests are performed in accordance with industry accepted standards. It is essential that the energy discharged from the battery during test be minimized to avoid the cost and delay associated with recharge. When defining the ideal high rate discharge test process one must consider these basic requirements. Immediately after formation, and preferably, after post cleaning, batteries are discharged at high current for a few seconds. The voltage under load at the end of test is determined and compared to nominal values resulting in a pass/fail decision. This paper discusses the effectiveness of the present high rate discharge test evaluation criteria in terms of it's ability to accurately discriminate between acceptable and unacceptable batteries. Variations in materials and manufacturing processes affect open-circuit voltage (OCV) and constant current voltage (CCV) measurements leading to erroneous pass/fail determinations. The paper will illustrate how these variations can be recognized and statistically evaluated. A supplemental evaluation criterion is presented which significantly improves the reliability of test results. This criterion is the gradient Δ V of the discharge curve. Evaluation of test data using this criterion yields information that directly correlates to the failure mode of the rejected battery, including irregularities in pasting and assembly. This paper concludes that the implementation of Δ V criterion significantly improves the failure detection of batteries subjected to production line high-rate discharge tests. Using the Δ V criterion to evaluate the test results is a more accurate determinant of an acceptable battery than the traditional criteria and results in fewer customer returns.

  6. Continuous Improvement in Battery Testing at the NASA/JSC Energy System Test Area

    Science.gov (United States)

    Boyd, William; Cook, Joseph

    2003-01-01

    The Energy Systems Test Area (ESTA) at the Lyndon B. Johnson Space Center in Houston, Texas conducts development and qualification tests to fulfill Energy System Division responsibilities relevant to ASA programs and projects. EST A has historically called upon a variety of fluid, mechanical, electrical, environmental, and data system capabilities spread amongst five full-service facilities to test human and human supported spacecraft in the areas of propulsion systems, fluid systems, pyrotechnics, power generation, and power distribution and control systems. Improvements at ESTA are being made in full earnest of offering NASA project offices an option to choose a thorough test regime that is balanced with cost and schedule constraints. In order to continue testing of enabling power-related technologies utilized by the Energy System Division, an especially proactive effort has been made to increase the cost effectiveness and schedule responsiveness for battery testing. This paper describes the continuous improvement in battery testing at the Energy Systems Test Area being made through consolidation, streamlining, and standardization.

  7. Automotive Battery Modelling and Management

    OpenAIRE

    N. M. Hammad

    2014-01-01

    The estimation of vehicle battery performance is typically addressed by testing the battery under specific operation conditions by using a model to represent the test results. Approaches for representing test results range from simple statistical models to neural networks to complex, physics-based models. Basing the model on test data could be problematical when testing becomes impractical with many years life time tests. So, real time estimation of battery performance, an important problem i...

  8. FIRST RESULTS FROM OEDOTENSIOMETRIC TESTS

    Directory of Open Access Journals (Sweden)

    Luigi Cavazza

    2008-09-01

    Full Text Available An oedotensiometer was used to examine to examine the behaviour of sieved sample of a swelling soil (a vertisol as well as of the same soils treated with solution of Na+ + Ca2+ to simulate the soil changes from excessive irrigation with brackish water. The oedometer test consisted in an infiltration of water from below through a ceramic porous plate at a feeding pressure of +10 cm water and successive drainage under a depression mostly of -112 cm of water. The rate of water entry as well as the swelling rate of the sample were monitored. Preliminary considerations regards the domains in which the shrinkage curve of a swelling soil is subdivided and make hypothesis on the swelling process expected when the infiltration from below of the sample is applied. The results support the hypothesis that when the water pressure is applied some water enters rather rapidly in the larger structural pores and is followed later by the swelling in the smaller pores, responsible for the basic domain. This first conclusion demonstrates that the assumption of a simultaneous movement of solid and liquid components in the sample, which is the base of most theoretical developments for swelling soils, cannot be accepted for the tested samples. Some cases with water clogging on the sample surface confirm a late final swelling of the soil and permitted to evaluate the hydraulic conductivity of the swollen soil. These manifestations are more evident in sodicated soils. The loading of the sample reduces the swelling of the sample and seems to reduce its permeability. The reduction of the feeding water pressure further reduces the sample swelling. The draining process from saturated soil sample shows that most of the process occurs in the large pores of the structural domain. This gives the possibility to evaluate the water diffusivity coefficient for the structural domain of the sample. In draining the soil with the highest sodication there was a variation of soil volume

  9. NIH Toolbox Cognition Battery (NIHTB-CB): list sorting test to measure working memory.

    Science.gov (United States)

    Tulsky, David S; Carlozzi, Noelle; Chiaravalloti, Nancy D; Beaumont, Jennifer L; Kisala, Pamela A; Mungas, Dan; Conway, Kevin; Gershon, Richard

    2014-07-01

    The List Sorting Working Memory Test was designed to assess working memory (WM) as part of the NIH Toolbox Cognition Battery. List Sorting is a sequencing task requiring children and adults to sort and sequence stimuli that are presented visually and auditorily. Validation data are presented for 268 participants ages 20 to 85 years. A subset of participants (N=89) was retested 7 to 21 days later. As expected, the List Sorting Test had moderately high correlations with other measures of working memory and executive functioning (convergent validity) but a low correlation with a test of receptive vocabulary (discriminant validity). Furthermore, List Sorting demonstrates expected changes over the age span and has excellent test-retest reliability. Collectively, these results provide initial support for the construct validity of the List Sorting Working Memory Measure as a measure of working memory. However, the relationship between the List Sorting Test and general executive function has yet to be determined. PMID:24959983

  10. 10 CFR Appendix Y to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Battery Chargers

    Science.gov (United States)

    2010-01-01

    ... of Battery Chargers Y Appendix Y to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Appendix Y to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Battery Chargers 1. Scope: This appendix covers the test requirements used to measure battery charger...

  11. Inconclusive TSC Genetic Test Results

    Science.gov (United States)

    ... genetic test does, essentially, is look for a “spelling error” in one of these genes that causes ... one or the other) has a mutation, or “spelling error” in it, it is not read correctly ...

  12. Application, sizing, testing and performance of the photovoltaic battery subsystem at Natural Bridges National Monument, Utah

    Science.gov (United States)

    Brench, B. L.

    1981-11-01

    During the two years from 24 May 1978 to 7 June 1980, the battery subsystem for the 100-kW peak photovoltaic power system for Natural Bridges National Monument was designed, modified, tested, installed, retested and again modified. The subsystem includes 224 lead-acid (with calcium alloy) cells, hydrogen recombiners, an air-lift pump system and electrolyte level indicators. Problems and solutions related to these subsystem components are discussed. Further details concerning the battery selection, design, tests and performance throughout the battery's life are also included.

  13. Study of a lithium-ion battery charge-discharge test unit characteristics*

    Science.gov (United States)

    Kopylov, E. A.; Mizrah, E. A.; Fedchenko, A. S.; Lobanov, D. K.

    2016-04-01

    The article describes the structure of a charge-discharge unit which allows to perform electrical, resource and thermal testing of several lithium-ion batteries simultaneously. The principle of operation of a one battery research channel (BRC) is shown. This study evaluated the stabilization error and rate of change of charge/discharge currents, the switching time from the charge mode to the discharge mode and vice versa for a single BRC and parallel BRCs. The possibility of increasing the maximum battery testing current due to the parallel connection of multiple BRCs without using a current alignment device between channels was discussed.

  14. Early results from a systems approach to improving the performance and lifetime of lead acid batteries

    Science.gov (United States)

    Kellaway, M. J.; Jennings, P.; Stone, D.; Crowe, E.; Cooper, A.

    Lead acid batteries offer important advantages in respect of unit cost and ease of recycling. They also have good power and low temperature performance. However, for hybrid electric vehicle (HEV) duty with their extreme rates and continuous PSoC operation, improvements are required to significantly extend service life. The Reliable Highly Optimised Lead Acid Battery (RHOLAB) project is taking a radical approach to the design of a lead acid HEV battery pack to address this issue, taking a systems approach to produce a complete pack that is attractive to vehicle manufacturers. This paper describes the project at an intermediate stage where some testing has been completed and the construction of the complete pack system is well under way.

  15. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  16. Indices of cognitive function measured in rugby union players using a computer-based test battery.

    Science.gov (United States)

    MacDonald, Luke A; Minahan, Clare L

    2016-09-01

    The purpose of this study was to investigate the intra- and inter-day reliability of cognitive performance using a computer-based test battery in team-sport athletes. Eighteen elite male rugby union players (age: 19 ± 0.5 years) performed three experimental trials (T1, T2 and T3) of the test battery: T1 and T2 on the same day and T3, on the following day, 24 h later. The test battery comprised of four cognitive tests assessing the cognitive domains of executive function (Groton Maze Learning Task), psychomotor function (Detection Task), vigilance (Identification Task), visual learning and memory (One Card Learning Task). The intraclass correlation coefficients (ICCs) for the Detection Task, the Identification Task and the One Card Learning Task performance variables ranged from 0.75 to 0.92 when comparing T1 to T2 to assess intraday reliability, and 0.76 to 0.83 when comparing T1 and T3 to assess inter-day reliability. The ICCs for the Groton Maze Learning Task intra- and inter-day reliability were 0.67 and 0.57, respectively. We concluded that the Detection Task, the Identification Task and the One Card Learning Task are reliable measures of psychomotor function, vigilance, visual learning and memory in rugby union players. The reliability of the Groton Maze Learning Task is questionable (mean coefficient of variation (CV) = 19.4%) and, therefore, results should be interpreted with caution. PMID:26756946

  17. EMOTICOM: A Neuropsychological Test Battery to Evaluate Emotion, Motivation, Impulsivity, and Social Cognition

    OpenAIRE

    Bland, Amy R.; Roiser, Jonathan P.; Mehta, Mitul A; Schei, Thea; Boland, Heather; Campbell-Meiklejohn, Daniel K.; Emsley, Richard A; Munafo, Marcus R; Penton-Voak, Ian S.; Seara-Cardoso, Ana; Viding, Essi; Voon, Valerie; Sahakian, Barbara J.; Robbins, Trevor W.; Elliott, Rebecca

    2016-01-01

    BACKGROUND: In mental health practice, both pharmacological and non-pharmacological treatments are aimed at improving neuropsychological symptoms, including cognitive and emotional impairments. However, at present there is no established neuropsychological test battery that comprehensively covers multiple affective domains relevant in a range of disorders. Our objective was to generate a standardised test battery, comprised of existing, adapted and novel tasks, to assess four core domains of ...

  18. Assessment of chemicals using a battery of neurobehavioral tests: a comparative study.

    Science.gov (United States)

    Pryor, G T; Uyeno, E T; Tilson, H A; Mitchell, C L

    1983-01-01

    of the dose-response functions after 15 weeks of dosing indicated clearly different patterns of effect among the eight chemicals. A composite score derived from a multidimensional analysis of the data suggested that the eight chemicals could be ranked from most to least neurotoxic as defined by these tests as acrylamide greater than methylmercury greater than chlordecone greater than tetraethyl tin greater than triethyl lead greater than lead acetate greater than arsenic greater than monosodium salicylate. This ranking and the results in general are in good agreement with what is known about these chemicals from other experiments with animals and from human experience. This battery of tests, or subsets thereof, may therefore have utility in the assessment of the potential neurobehavioral toxicity of various chemicals. PMID:6190097

  19. Ultrasonic Transducer Irradiation Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Palmer, Joe [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Keller, Paul [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Montgomery, Robert [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chien, Hual-Te [Argonne National Lab. (ANL), Argonne, IL (United States); Kohse, Gordon [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States); Tittmann, Bernhard [Pennsylvania State Univ., University Park, PA (United States); Reinhardt, Brian [Pennsylvania State Univ., University Park, PA (United States); Rempe, Joy [Rempe and Associates, Idaho Falls, ID (United States)

    2015-02-01

    Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric

  20. Ultrasonic Transducer Irradiation Test Results

    International Nuclear Information System (INIS)

    Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric transducer and two

  1. GALEN skin test study III: Minimum battery of test inhalent allergens needed in epidemiological studies in patients

    DEFF Research Database (Denmark)

    Bousquet, P-J; Burbach, G; Heinzerling, L M;

    2009-01-01

    Background: The number of allergens to be tested in order to identify sensitized patients is important in order to have the most cost-effective approach in epidemiological studies. Objective: To define the minimal number and the type of skin prick test (SPT) allergens required to identify a patient...... as sensitized using results of the new Pan-European GA(2)LEN skin prick test study. Method: In a large Pan-European multicenter (17 centers in 14 countries) patient based study, a standardized panel of 18 allergens has been prick tested using a standardized procedure. Conditional approach allowed to determine...... or Alternaria]). According to country, up to 13 allergens were needed to identify all sensitized subjects. Conclusion: Eight to ten allergens allowed the identification of the majority of sensitized subjects. For clinical care of individual patients, the whole battery of 18 allergens is needed to appropriately...

  2. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m2 for each rod. After a flow reduction to 1800 kg/s-m2, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  3. Research results from the Advanced Lead-Acid Battery Consortium point the way to longer life and higher specific energy for lead/acid electric-vehicle batteries

    Science.gov (United States)

    Moseley, P. T.

    Amidst the welter of publicity devoted to the newer battery chemistries, the remarkable progress made by lead/acid battery technologists in response to the needs of the emerging electric-vehicle market has tended to be overlooked. The flooded design of battery, launched by Gaston Planté around 1860, has given way to a valve-regulated variant which has a history dating only from the 1970s. The key parameters of this `maintenance free' battery have been improved markedly during the course of the development programme of the Advanced Lead-Acid Battery Consortium (ALABC), and it is likely that lead/acid will continue to feature strongly in motive-power applications as a result of its cost advantage and of its enhanced effectiveness.

  4. Early Education Screening Test Battery of Basic Skills Development: Criteria for Personalizing Programs.

    Science.gov (United States)

    University City School District, MO.

    The development and content of the Early Education Screening Test Battery are described elsewhere (TM 000 184). This report provides norms for the Gross Motor Test (GMO), Visual-Motor Integration (VMI), four scales of the Illinois Test of Psycholinguistic Abilities (ITPA), Peabody Picture Vocabulary Test (PPVT), and the Behavior Rating Scale…

  5. PSOC cycle testing method for lithium-ion secondary batteries

    Science.gov (United States)

    Kato, Ken; Negishi, Akira; Nozaki, Ken; Tsuda, Izumi; Takano, Kiyonami

    A cycle testing procedure is proposed which carries out charge and discharge in a partial state of charge (PSOC) with some testing levels such as an averaged state of charge, temperature, etc. The PSOC cycle test with this procedure was carried out for a commercial lithium-ion cell for about 20,000 cycles, and the testing procedure and test results are discussed. The features of the degradation due to PSOC cycle test in the tested lithium-ion cell were clarified as follows. The degradation during the PSOC cycle test was greater at higher environmental temperature. The degradation was greatest at a high average SOC, and smallest at SOC=50%. The degradation increased again at a low average SOC. In the test results for 2 years with 20,000 PSOC cycles, which converted to 2200 cycles of full-capacity charge and discharge, capacity degradation was 32% even at the greatest degradation at 318 K and 8% or less at 278 K. The proposed testing procedure is useful for evaluating a cell used on partial charge and discharge cycles.

  6. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m2. After a flow reduction to 2120 kg/s-m2, film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  7. Results of Neptunium Disposal Testing

    International Nuclear Information System (INIS)

    Researchers investigated the neutralization of neptunium solution from H-Canyon Tank 16.4 and the properties of the resulting slurry. This work investigated slurry properties from a single neutralization protocol and limited storage times

  8. Installing a Test Tap on a Metal Battery Case

    Science.gov (United States)

    Mayes, Daniel R.; Rybicki, Daniel J.

    2009-01-01

    A mechanical fitting and relatively simple and safe method of installing it on the metal case of a battery have been devised to provide access to the interior of the battery to perform inspection and/or to measure such internal conditions as temperature and pressure. A metal boss or stud having an exterior thread is attached to the case by capacitor-discharge stud welding (CDSW), which takes only 3 to 6 milliseconds and in which the metallurgical bond (weld) and the heat-affected zone are limited to a depth of a few thousandths of an inch (a few hundredths of a millimeter). These characteristics of CDSW prevent distortion of the case and localized internal heating that could damage the chemical components inside of the battery. An access hole is then drilled through the stud and case, into the interior of the battery. A mechanical fitting having a matching thread is installed on the stud and the interior end of the fitting is sealed with a pressure-sealing washer/gasket. The exterior end of the fitting is configured for attachment of whatever instrumentation is required for the selected inspection or measurement.

  9. Vibration Durability Testing of Nickel Cobalt Aluminum Oxide (NCA Lithium-Ion 18650 Battery Cells

    Directory of Open Access Journals (Sweden)

    James Michael Hooper

    2016-04-01

    Full Text Available This paper outlines a study undertaken to determine if the electrical performance of Nickel Cobalt Aluminum Oxide (NCA 3.1 Ah 18650 battery cells can be degraded by road induced vibration typical of an electric vehicle (EV application. This study investigates if a particular cell orientation within the battery assembly can result in different levels of cell degradation. The 18650 cells were evaluated in accordance with Society of Automotive Engineers (SAE J2380 standard. This vibration test is synthesized to represent 100,000 miles of North American customer operation at the 90th percentile. This study identified that both the electrical performance and the mechanical properties of the NCA lithium-ion cells were relatively unaffected when exposed to vibration energy that is commensurate with a typical vehicle life. Minor changes observed in the cell’s electrical characteristics were deemed not to be statistically significant and more likely attributable to laboratory conditions during cell testing and storage. The same conclusion was found, irrespective of cell orientation during the test.

  10. Running Test of VVVF Inverter Type Railcar Using Lithium Ion Battery

    OpenAIRE

    Ogihara, Takashi; YAMANAKA, Shigenobu

    2009-01-01

    Lithium ion battery was applied to the running of VVVF inverter type railcar. 15kWh of Mn type lithium ion battery was used. The relation between running time and voltage, current and integrating watt was investigated. The running test was also carried out using VVVF inverter type railcar to investigate charge performance due to regenerative energy. Lithium ion battery module was quickly charged for three times at rate of 4.68C by regenerative braking system. It was estimated that the effect ...

  11. Performance Testing of Lithium Li-ion Cells and Batteries in Support of JPL's 2003 Mars Exploration Rover Mission

    Science.gov (United States)

    Smart, Marshall C.; Ratnakumar, B. V.; Ewell, R. C.; Whitcanack, L. D.; Surampudi, S.; Puglia, F.; Gitzendanner, R.

    2007-01-01

    In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20(super 0)C to +40(super 0)C), withstand long storage periods (e.g., including pre-launch and cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the inability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit RBAU), consisting of two 8-cell 8 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The primary focus of this paper is to communicate the latest results regarding Mars surface operation mission simulation testing, as well as, the corresponding performance capacity loss and impedance characteristics as a function of temperature and life. As will be discussed, the lithium-ion batteries (fabricated by Yardney Technical Products, Inc.) have been demonstrated to far exceed the requirements defined by the mission, being able to support the operation of the rovers for over three years, and are projected to support an even further extended mission.

  12. Hybrid Vehicle Comparison Testing Using Ultracapacitor vs. Battery Energy Storage (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Gonder, J.; Pesaran, A.; Lustbader, J.; Tataria, H.

    2010-02-01

    With support from General Motors, NREL researchers converted and tested a hybrid electric vehicle (HEV) with three energy storage configurations: a nickel metal-hydride battery and two ultracapacitor (Ucap) modules. They found that the HEV equipped with one Ucap module performed as well as or better than the HEV with a stock NiMH battery configuration. Thus, Ucaps could increase the market penetration and fuel savings of HEVs.

  13. Performance Model for High-Power Lithium Titanate Oxide Batteries based on Extended Characterization Tests

    DEFF Research Database (Denmark)

    Stroe, Ana-Irina; Swierczynski, Maciej Jozef; Stroe, Daniel Ioan;

    2015-01-01

    Lithium-ion (Li-ion) batteries are found nowadays not only in portable/consumer electronics but also in more power demanding applications, such as stationary renewable energy storage, automotive and back-up power supply, because of their superior characteristics in comparison to other energy...... model for a commercially available 13Ah high-power lithium titanate oxide battery cell based on laboratory-performed extended characterization tests....

  14. Recharging the battery: placement tests for ESP students

    Directory of Open Access Journals (Sweden)

    Maria Isabel Azevedo Cunha

    2001-02-01

    Full Text Available

    This paper first reviews key concepts in language testing and discusses the use of the English Language Placement Test administered at the Catholic University of Rio de Janeiro to computer science students, who are required t o take one of the two ESP courses offered by the English program. The analysis of the scores on two versions of a test administered to two different groups of computer science students who took the examination in sequential semesters is presented. For the original test, it em facility and it em discrimination were calculated, then overall test reliability was estimated. The statistics were carefully examined and a number of t he test items were eliminated, revamped or replaced in creating a revised version of the test. This modified and improved version of the test was then administered to a second group of students and the same statistics were applied once more. The results are discussed in terms of the importance of item analysis and revision for providing more consistent and accurate language testing instruments.

  15. Fireworks Assembler (Fireworks) 737.887 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  16. Factor Analysis and Validity Study of the Law School Admission Test Battery.

    Science.gov (United States)

    Carlson, Alfred B.

    A factor analysis of the Law School Admission Test (LSAT) battery was undertaken to gain a better understanding of the specific abilities which contribute to performance on the tests. To determine whether greater amounts of testing time should be allocated to groups of items defined by the factor analysis, a validity study was conducted. Existing…

  17. Radiologic Technologist (medical ser.) 078.368 -- Technical Report on Development of USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  18. Development of USES Aptitude Test Battery for Manager, Beauty Shop (per. ser.)-187.168.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  19. Order of Conners' CPT-II Administration within a Cognitive Test Battery Influences ADHD Indices

    Science.gov (United States)

    Erdodi, Laszlo A.; Lajiness-O'Neill, Renee; Saules, Karen K.

    2010-01-01

    Objective: To study the effect of administration sequence on Conner's continuous performance test (CPT-II) scores in clients requesting psychological assessment. It was hypothesized that when administered at the end rather than beginning of a test battery, the test scores will show higher symptom severity. If present, order effects may cause the…

  20. Test Series 2: seismic-fragility tests of naturally-aged Class 1E Exide FHC-19 battery cells

    International Nuclear Information System (INIS)

    The seismic-fragility of naturally-aged nuclear station safety-related batteries is of interest for two reasons: (1) to determine actual failure modes and their thresholds and (2) to determine the validity of using the electrical capacity of individual cells as an indicator of the ''end-of-life'' of a battery if subjected to a seismic event. This report, the second in a test series of an extensive seismic research program, covers the testing of 10-year old lead-calcium Exide FHC-19 cells from the Calvert Cliffs Nuclear Power Station operated by the Baltimore Gas and Electric Company. The Exide cells were tested in two configurations using a triaxial shake table: single-cell tests, both rigidly and loosely mounted; and multicell (three-cell) tests, mounted in a typical battery rack. A total of six electrically active cells was used in the two different cell configurations

  1. Test Series 4: seismic-fragility tests of naturally-aged Exide EMP-13 battery cells

    International Nuclear Information System (INIS)

    This report, the fourth in a test series of an extensive seismic research program, covers the testing of a 27-year old lead-antimony Exide EMP-13 cells from the recently decommissioned Shippingport Atomic Power Station. The Exide cells were tested in two configurations using a triaxial shake table: single-cell tests, rigidly mounted; and multicell (five-cell) tests, mounted in a typical battery rack. A total of nine electrically active cells was used in the two different cell configurations. None of the nine cells failed during the actual seismic tests when a range of ZPAs up to 1.5 g was imposed. Subsequent discharge capacity tests of five of the cells showed, however, that none of the cells could deliver the accepted standard of 80% of their rated electrical capacity for 3 hours. In fact, none of the 5 cells could deliver more than a 33% capacity. Two of the seismically tested cells and one untested, low capacity cell were disassembled for examination and metallurgical analyses. The inspection showed the cells to be in poor condition. The negative plates in the vicinity of the bus connections were extremely weak, the positive buses were corroded and brittle, negative and positive active material utilization was extremely uneven, and corrosion products littered the cells

  2. Protocol of Electrochemical Test and Characterization of Aprotic Li-O2 Battery.

    Science.gov (United States)

    Luo, Xiangyi; Wu, Tianpin; Lu, Jun; Amine, Khalil

    2016-01-01

    We demonstrate a method for electrochemical testing of an aprotic Li-O2 battery. An aprotic Li-O2 battery is made of a Li-metal anode, an aprotic electrolyte, and an O2-breathing cathode. The aprotic electrolyte is a solution of lithium salt with aprotic solvent; and porous carbon is commonly used as the cathode substrate. To improve the performance, an electrocatalyst is deposited onto the porous carbon substrate by certain deposition methods, such as atomic layer deposition (ALD) and wet-chemistry reaction. The as-prepared cathode materials are characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray absorption near edge structure (XANES). A Swagelok-type cell, sealed in a glass chamber filled with pure O2, is used for the electrochemical test on a battery test system. The cells are tested under either capacity-controlled mode or voltage controlled mode. The reaction products are investigated by electron microscopy, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy, and Raman spectroscopy to study the possible pathway of oxygen reduction reaction (ORR) and oxygen evolution reaction (OER). This protocol demonstrates a systematic and efficient arrangement of routine tests of the aprotic Li-O2 battery, including the electrochemical test and characterization of battery materials. PMID:27501292

  3. Experimental Testing Procedures and Dynamic Model Validation for Vanadium Redox Flow Battery Storage System

    DEFF Research Database (Denmark)

    Baccino, Francesco; Marinelli, Mattia; Nørgård, Per Bromand;

    2013-01-01

    The paper aims at characterizing the electrochemical and thermal parameters of a 15 kW/320 kWh vanadium redox flow battery (VRB) installed in the SYSLAB test facility of the DTU Risø Campus and experimentally validating the proposed dynamic model realized in Matlab-Simulink. The adopted testing...... efficiency of the battery system. The test procedure has general validity and could also be used for other storage technologies. The storage model proposed and described is suitable for electrical studies and can represent a general model in terms of validity. Finally, the model simulation outputs are...

  4. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  5. Salivary chromogranin-A as a marker of psychological stress during a cognitive test battery in humans.

    Science.gov (United States)

    Kanamaru, Yoshiki; Kikukawa, Azusa; Shimamura, Keiichi

    2006-09-01

    The purpose of the present study was to evaluate the salivary Chromogranin-A (CgA) response to the psychological stress induced by a cognitive test battery. The subjects were 14 healthy volunteers administered the cognitive test battery CogScreen Aeromedical Edition (CogScreen-AE). CogScreen-AE is a test of reaction time and fundamental cognitive ability in the assessment of aeroplane pilots. The subjects were given five batteries of the test (1st approximately 5th) on separate days with 2 week intervals. Saliva samples were collected at 20 min before the test (BASE), immediately before the test (PRE), in the middle of the test (MID), and 5 min after the test (POS) for each subject. The concentration of CgA was determined by enzyme-linked immunosorbent assay. ANOVA revealed a significant by time interaction (BASE, PRE, MID and POS) without a significant effect of battery interaction (1st, 2nd, 3rd, 4th and 5th). The CgA concentration increased at PRE (2.46 +/- 0.24 pmol.mg protein- 1) from BASE (1.19 +/- 0.10 pmol.mg protein- 1). CgA level remained increased in the MID (2.90 +/- 0.26 pmol.mg protein- 1) and remained high in the POS samples (2.81 +/- 0.23 pmol.mg protein- 1). Salivary CgA remained at basal levels during a control study over the same time course without exposure to CogScreen-AE. The changes in salivary CgA secretion as a result of exposure to a cognitive task may indicate psychological stress in humans. PMID:17060047

  6. An assessment of the Performance-Based Measurement Battery (PBMB), the Navy's psychomotor supplemt to the Aviation Selection Test Battery (ASTB)

    OpenAIRE

    Ostoin, Steven D.

    2007-01-01

    The Aviation Selection Test Battery (ASTB) has been used to screen prospective aviation candidates for the Navy, Marines, and Coast Guard since World War II. The Navy has continuously looked for ways to update and improve its aviation screening procedures and the latest supplement of the Performance-Based Measurement Battery (PBMB) currently under development is just one example. The Naval Operational Medicine Institute (NOMI) is currently investigating how well this test will assist ...

  7. GENETIC ACTIVITY PROFILES AND PATTERN RECOGNITION IN TEST BATTERY SELECTION (JOURNAL VERSION)

    Science.gov (United States)

    Computer-generated genetic activity profiles and pairwise matching procedures may aid in the selection of the most appropriate short-term bioassays to be used in test batteries for the evaluation of the genotoxicity of a given chemical or group of chemicals. Selection of test bat...

  8. Modeling and Operational Testing of an Isolated Variable Speed PMSG Wind Turbine with Battery Energy Storage

    Directory of Open Access Journals (Sweden)

    BAROTE, L.

    2012-05-01

    Full Text Available This paper presents the modeling and operational testing of an isolated permanent magnet synchronous generator (PMSG, driven by a small wind turbine with a battery energy storage system during wind speed and load variations. The whole system is initially modeled, including the PMSG, the boost converter and the storage system. The required power for the connected loads can be effectively delivered and supplied by the proposed wind turbine and energy storage systems, subject to an appropriate control method. Energy storage devices are required for power balance and power quality in stand alone wind energy systems. The main purpose is to supply 230 V / 50 Hz domestic appliances through a single-phase inverter. The experimental waveforms, compared to the simulation results, show a good prediction of the electrical variable parameters. Furthermore, it can be seen that the results validate the stability of the supply.

  9. Internal Structure and Partial Invariance across Gender in the Spanish Version of the Reasoning Test Battery.

    Science.gov (United States)

    Elosua, Paula; Mujika, Josu

    2015-01-01

    The Reasoning Test Battery (BPR) is an instrument built on theories of the hierarchical organization of cognitive abilities and therefore consists of different tasks related with abstract, numerical, verbal, practical, spatial and mechanical reasoning. It was originally created in Belgium and later adapted to Portuguese. There are three forms of the battery consisting of different items and scales which cover an age range from 9 to 22. This paper focuses on the adaptation of the BPR to Spanish, and analyzes different aspects of its internal structure: (a) exploratory item factor analysis was applied to assess the presence of a dominant factor for each partial scale; (b) the general underlined model was evaluated through confirmatory factor analysis, and (c) factorial invariance across gender was studied. The sample consisted of 2624 Spanish students. The results concluded the presence of a general factor beyond the scales, with equivalent values for men and women, and gender differences in the factorial structure which affect the numerical reasoning, abstract reasoning and mechanical reasoning scales. PMID:26459054

  10. Low-Earth-Orbit and Geosynchronous-Earth-Orbit Testing of 80 Ah Batteries under Real-Time Profiles

    Science.gov (United States)

    Staniewicz, Robert J.; Willson, John; Briscoe, J. Douglas; Rao, Gopalakrishna, M.

    2006-01-01

    To date the LEO battery has completed 5000 nominal cycles.The EODV is trending down by 50mV per 1000 cycles. To date the GEO battery has completed 2 nominal shadow periods and currently in sunlight period. Batteries testing after one year looks encouraging for aerospace application. There are no discrepancies between the current data and extensive testing conducted at Saft over the past 5 years.

  11. Component and subscale testing in support of the design of a battery power supply for the electromagnetic gun research facility

    International Nuclear Information System (INIS)

    A high power and high energy battery system is being designed to support electromagnetic (EM) gun research requirements of the Air Force Armament Laboratory, Eglin Air Force Base, Florida. Design goals are for a battery power supply which uses current technology to provide megawatts of power. Test data on the pulsed power performance of the batteries, switches, and other components to be utilized in this system are presented along with details of plans for subscale system testing to validate the system design

  12. Fast Charging and Smart Charging Tests for Electric Vehicles Batteries Using Renewable Energy

    Directory of Open Access Journals (Sweden)

    Forero Camacho Oscar Mauricio

    2016-01-01

    Full Text Available Electric Vehicles (EV technologies are still relatively new and under strong development. Although some standardized solutions are being promoted and becoming a new trend, there is an outstanding need for common platforms and sharing of knowledge and core technologies. This paper presents the development of a test platform, including three Li-ion batteries designed for EV applications, and three associated bi-directional power converters, for testing impacts on different advanced loadings of EV batteries. Different charging algorithms/profiles have been tested, including constant current and power, and forced and pulsed power. The aim of the tests has been to study the impact of smart charging and fast charging on the power system, on the battery state of health and degradation, and to find out the limitations of the batteries for a Smart Grid. The paper outlines the advantages and disadvantages of both tests in terms of regulation of the aggregated local power, power capacity and the power exchange with the grid. The smart charging tests performed have demonstrated that even with a simple control algorithm, without any forecasting, it is possible to provide the required charging and at the same time the power system services, reducing the peak power and the energy losses in the power connection line of the power exchange with the national grid.

  13. Evaluation of genotoxicity through micronuclei test in workers of car and battery repair garages

    Directory of Open Access Journals (Sweden)

    M.G. Martino-Roth

    2002-01-01

    Full Text Available In this study, the micronuclei test (MNT was applied in exfoliated cells of buccal mucosa, in order to evaluate the genotoxic risk associated with occupational exposure of mechanics, storage battery renovation workers, and car painters. For each individual, 3000 exfoliated buccal cells were analyzed. There was a significantly higher frequency of micronucleated cells (MNC in the exposed workers than in controls. Smoking and drinking habits, age, and working time did not represent significant factors in terms of increasing the production of micronuclei (MN, when the control and the exposed groups were compared. These results allowed to conclude that the studied individuals belong to a risk group and should periodically undergo biological monitoring and proper care.

  14. 78 FR 58574 - Maintenance, Testing, and Replacement of Vented Lead-Acid Storage Batteries for Nuclear Power Plants

    Science.gov (United States)

    2013-09-24

    ... COMMISSION Maintenance, Testing, and Replacement of Vented Lead-Acid Storage Batteries for Nuclear Power..., Testing, and Replacement of Vented Lead-Acid Storage Batteries for Nuclear Power Plants.'' The guide... nuclear power plants. ADDRESSES: Please refer to Docket ID NRC-2013-0048 when contacting the NRC about...

  15. The placenta in toxicology. Part IV: Battery of toxicological test systems based on human placenta.

    Science.gov (United States)

    Göhner, Claudia; Svensson-Arvelund, Judit; Pfarrer, Christiane; Häger, Jan-Dirk; Faas, Marijke; Ernerudh, Jan; Cline, J Mark; Dixon, Darlene; Buse, Eberhard; Markert, Udo R

    2014-01-01

    This review summarizes the potential and also some limitations of using human placentas, or placental cells and structures for toxicology testing. The placenta contains a wide spectrum of cell types and tissues, such as trophoblast cells, immune cells, fibroblasts, stem cells, endothelial cells, vessels, glands, membranes, and many others. It may be expected that in many cases the relevance of results obtained from human placenta will be higher than those from animal models due to species specificity of metabolism and placental structure. For practical and economical reasons, we propose to apply a battery of sequential experiments for analysis of potential toxicants. This should start with using cell lines, followed by testing placenta tissue explants and isolated placenta cells, and finally by application of single and dual side ex vivo placenta perfusion. With each of these steps, the relative workload increases while the number of feasible repeats decreases. Simultaneously, the predictive power enhances by increasing similarity with in vivo human conditions. Toxic effects may be detected by performing proliferation, vitality and cell death assays, analysis of protein and hormone expression, immunohistochemistry or testing functionality of signaling pathways, gene expression, transport mechanisms, and so on. When toxic effects appear at any step, the subsequent assays may be cancelled. Such a system may be useful to reduce costs and increase specificity in testing questionable toxicants. Nonetheless, it requires further standardization and end point definitions for better comparability of results from different toxicants and to estimate the respective in vivo translatability and predictive value. PMID:23548605

  16. Development and testing of a bipolar lead-acid battery for hybrid electric vehicles

    NARCIS (Netherlands)

    Saakes, M.; Kluiters, E.; Schmal, D.; Mourad, S.; Have, P.T.J.H. ten

    1999-01-01

    An 80 V bipolar lead-acid battery was constructed and tested using hybrid electric vehicle (HEV) drive cycles. Drive cycles with a peak power of 6.7 kW, equal to 1/5 of the total power profile required for the HEV studied, were run successfully. Model calculations showed that the 80 V module constru

  17. EMOTICOM: A Neuropsychological Test Battery to Evaluate Emotion, Motivation, Impulsivity, and Social Cognition.

    Science.gov (United States)

    Bland, Amy R; Roiser, Jonathan P; Mehta, Mitul A; Schei, Thea; Boland, Heather; Campbell-Meiklejohn, Daniel K; Emsley, Richard A; Munafo, Marcus R; Penton-Voak, Ian S; Seara-Cardoso, Ana; Viding, Essi; Voon, Valerie; Sahakian, Barbara J; Robbins, Trevor W; Elliott, Rebecca

    2016-01-01

    In mental health practice, both pharmacological and non-pharmacological treatments are aimed at improving neuropsychological symptoms, including cognitive and emotional impairments. However, at present there is no established neuropsychological test battery that comprehensively covers multiple affective domains relevant in a range of disorders. Our objective was to generate a standardized test battery, comprised of existing, adapted and novel tasks, to assess four core domains of affective cognition (emotion processing, motivation, impulsivity and social cognition) in order to facilitate and enhance treatment development and evaluation in a broad range of neuropsychiatric disorders. The battery was administered to 200 participants aged 18-50 years (50% female), 42 of whom were retested in order to assess reliability. An exploratory factor analysis identified 11 factors with eigenvalues greater than 1, which accounted for over 70% of the variance. Tasks showed moderate to excellent test-retest reliability and were not strongly correlated with demographic factors such as age or IQ. The EMOTICOM test battery is therefore a promising tool for the assessment of affective cognitive function in a range of contexts. PMID:26941628

  18. Rapid screening for soil ecotoxicity with a battery of luminescent bacteria tests.

    Science.gov (United States)

    Heinlaan, Margit; Kahru, Anne; Kasemets, Kaja; Kurvet, Imbi; Waterlot, Cristophe; Sepp, Kalev; Dubourguier, Henri-Charles; Douay, Francis

    2007-03-01

    A bacterial test battery, involving i) Microtox, an aquatic test, ii) the Flash assay, a soil-suspension test (with Vibrio fischeri as the test organism), and iii) the Metal Detector assay, a semi-specific aquatic test for heavy metals (with recombinant luminescent Escherichia coli), was used in a combined toxicological and chemical hazard assessment of Estonian soils sampled from a former Soviet military airfield (13 samples) and from traffic-influenced roadsides (5 samples). The soils showed slightly elevated levels of total petroleum hydrocarbons (TPH), but not of heavy metals. In most of the samples, the levels of TPH did not exceed the Estonian permitted limit values set for residential areas. Toxicity testing was performed on both fresh and dried soils, after aqueous extraction for 1 hour and 24 hours. The toxicity results obtained with the Microtox test did not significantly differ in all of the sample treatment schemes; however, it appeared that the drying and sieving of the soils increased the bioavailability of toxicants, probably due to an enlarged reactive soil surface area. According to chemical analysis of the soils and the data from the Microtox test and the Metal Detector assay (performed on aqueous elutriates of the soils), these soils would not be considered to be hazardous. In contrast, the Flash assay performed on soil-water suspensions of dried soils, showed that most of the soils were toxic and thus probably contained undetermined particle-bound bioavailable toxicants. The photobacterial toxicity test (the Flash assay) can be recommended for the rapid screening of soils, as it is sensitive, cheap and inexpensive, and provides valuable information on particle-bound bioavailable toxicants, useful for complementing a chemical analysis and for assessing the risks originating from polluted soils. PMID:17411358

  19. Fast Charging and Smart Charging Tests for Electric Vehicles Batteries Using Renewable Energy

    DEFF Research Database (Denmark)

    Forero Camacho, Oscar Mauricio; Mihet-Popa, Lucian

    2016-01-01

    Electric Vehicles (EV) technologies are still relatively new and under strong development. Although some standardized solutions are being promoted and becoming a new trend, there is an outstanding need for common platforms and sharing of knowledge and core technologies. This paper presents...... the development of a test platform, including three Li-ion batteries designed for EV applications, and three associated bi-directional power converters, for testing impacts on different advanced loadings of EV batteries. Different charging algorithms/profiles have been tested, including constant current and power...... of both tests in terms of regulation of the aggregated local power, power capacity and the power exchange with the grid. The smart charging tests performed have demonstrated that even with a simple control algorithm, without any forecasting, it is possible to provide the required charging and at the same...

  20. Use of computerized test batteries for quantifying neurobehavioral outcomes.

    OpenAIRE

    Letz, R

    1991-01-01

    Neurobehavioral testing provides for noninvasive assessment of the functional integrity of the nervous system. Neurobehavioral tests have been used as quantitative outcome measures in a number of epidemiologic investigations of the potential effects on the nervous system from exposure to organic solvents, heavy metals, and pesticides. Because of the functional complexity of the nervous system, sets of tests assessing a range of functions have been used, with inconsistency from one study to an...

  1. Test series 1: seismic-fragility tests of naturally-aged Class 1E Gould NCX-2250 battery cells

    International Nuclear Information System (INIS)

    The seismic-fragility response of naturally-aged, nuclear station, safety-related batteries is of interest for two reasons: (1) to determine actual failure modes and thresholds; and (2) to determine the validity of using the electrical capacity of individual cells as an indicator of the end-of-life of a battery, given a seismic event. This report covers the first test series of an extensive program using 12-year old, lead-calcium, Gould NCX-2250 cells, from the James A. Fitzpatrick Nuclear Power Station operated by the New York Power Authority. Seismic tests with three cell configurations were performed using a triaxial shake table: single-cell tests, rigidly mounted; multi-cell (three) tests, mounted in a typical battery rack; and single-cell tests specifically aimed towards examining propagation of pre-existing case cracks. In general the test philosophy was to monitor the electrical properties including discharge capacity of cells through a graduated series of g-level step increases until either the shake-table limits were reached or until electrical failure of the cells occurred. Of nine electrically active cells, six failed during seismic testing over a range of imposed g-level loads in excess of a 1-g ZPA. Post-test examination revealed a common failure mode, the cracking at the abnormally brittle, positive lead bus-bar/post interface; further examination showed that the failure zone was extremely coarse grained and extensively corroded. Presently accepted accelerated-aging methods for qualifying batteries, per IEEE Std. 535-1979, are based on plate growth, but these naturally-aged 12-year old cells showed no significant plate growth

  2. Electrical Vehicle Batteries Testing in a Distribution Network Using Sustainable Energy

    DEFF Research Database (Denmark)

    Forero Camacho, Oscar Mauricio; Nørgård, Per Bromand; Rao, Ningling;

    2014-01-01

    , there is an outstanding need for common platforms and sharing of knowledge and core technologies. This paper presents the development of a test platform, including three Li-ion batteries designed for EV applications and three associated bi-directional power converters, for testing impacts on different advanced loadings...... in terms of regulation of the aggregated local power, power capacity and the power exchange with the grid....

  3. Results of steel containment vessel model test

    International Nuclear Information System (INIS)

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the US Nuclear Regulatory Commission. Two tests are being conducted: (1) a test of a model of a steel containment vessel (SCV) and (2) a test of a model of a prestressed concrete containment vessel (PCCV). This paper summarizes the conduct of the high pressure pneumatic test of the SCV model and the results of that test. Results of this test are summarized and are compared with pretest predictions performed by the sponsoring organizations and others who participated in a blind pretest prediction effort. Questions raised by this comparison are identified and plans for posttest analysis are discussed

  4. Psychometric properties and convergent and predictive validity of an executive function test battery for two-year-olds.

    Science.gov (United States)

    Mulder, Hanna; Hoofs, Huub; Verhagen, Josje; van der Veen, Ineke; Leseman, Paul P M

    2014-01-01

    Executive function (EF) is an important predictor of numerous developmental outcomes, such as academic achievement and behavioral adjustment. Although a plethora of measurement instruments exists to assess executive function in children, only few of these are suitable for toddlers, and even fewer have undergone psychometric evaluation. The present study evaluates the psychometric properties and validity of an assessment battery for measuring EF in two-year-olds. A sample of 2437 children were administered the assessment battery at a mean age of 2;4 years (SD = 0;3 years) in a large-scale field study. Measures of both hot EF (snack and gift delay tasks) and cool EF (six boxes, memory for location, and visual search task) were included. Confirmatory Factor Analyses showed that a two-factor hot and cool EF model fitted the data better than a one-factor model. Measurement invariance was supported across groups differing in age, gender, socioeconomic status (SES), home language, and test setting. Criterion and convergent validity were evaluated by examining relationships between EF and age, gender, SES, home language, and parent and teacher reports of children's attention and inhibitory control. Predictive validity of the test battery was investigated by regressing children's pre-academic skills and behavioral problems at age three on the latent hot and cool EF factors at age 2 years. The test battery showed satisfactory psychometric quality and criterion, convergent, and predictive validity. Whereas cool EF predicted both pre-academic skills and behavior problems 1 year later, hot EF predicted behavior problems only. These results show that EF can be assessed with psychometrically sound instruments in children as young as 2 years, and that EF tasks can be reliably applied in large scale field research. The current instruments offer new opportunities for investigating EF in early childhood, and for evaluating interventions targeted at improving EF from a young age. PMID

  5. Psychometric properties and convergent and predictive validity of an executive function test battery for two-year-olds

    Directory of Open Access Journals (Sweden)

    Hanna eMulder

    2014-07-01

    Full Text Available Executive function (EF is an important predictor of numerous developmental outcomes, such as academic achievement and behavioral adjustment. Although a plethora of measurement instruments exists to assess executive function in children, only few of these are suitable for toddlers, and even fewer have undergone psychometric evaluation. The present study evaluates the psychometric properties and validity of an assessment battery for measuring EF in two-year-olds. A sample of 2437 children were administered the assessment battery at a mean age of 2;4 years (SD = 0;3 years in a large-scale field study. Measures of both hot EF (snack and gift delay tasks and cool EF (six boxes, memory for location, and visual search task were included. Confirmatory Factor Analyses showed that a two-factor hot and cool EF model fitted the data better than a one-factor model. Measurement invariance was supported across groups differing in age, gender, socioeconomic status (SES, home language, and test setting. Criterion and convergent validity were evaluated by examining relationships between EF and age, gender, SES, home language, and parent and teacher reports of children’s attention and inhibitory control. Predictive validity of the test battery was investigated by regressing children’s pre-academic skills and behavioral problems at age three on the latent hot and cool EF factors at age two years. The test battery showed satisfactory psychometric quality and criterion, convergent, and predictive validity. Whereas cool EF predicted both pre-academic skills and behavior problems one year later, hot EF predicted behavior problems only. These results show that EF can be assessed with psychometrically sound instruments in children as young as two years, and that EF tasks can be reliably applied in large scale field research. The current instruments offer new opportunities for investigating EF in early childhood, and for evaluating interventions targeted at improving

  6. Assessment of high power HEV lead-acid battery advancements by comparative benchmarking with a European test procedure

    Science.gov (United States)

    Conte, Mario; Pede, Giovanni; Sglavo, Vincenzo; Macerata, Diego

    The technical and practical suitability of lead-acid batteries for applications in vehicles with electrical drivetrains (battery-powered or hybrid electric) has been experimentally investigated in a variety of testing programmes. Under the direction and funding support of the Commission of the European Community, since early 1990s, the R&D Organisation EUCAR, a collaborative partnership of most European car manufacturers, has been conducting battery technological assessment projects, through bench tests carried out by different independent laboratories throughout Europe, using agreed test procedures. In this framework, ENEA acted as independent testing institute and tested, among others, three high power lead-acid batteries of various technologies (flat plate electrodes and spiral wound) for EV and HEV applications. In addition, different battery sizes and operating conditions have been tested at ENEA in a separate collaboration with ALTRA-IRISBUS. This paper intends to trace technological and performance improvements of high power lead-acid battery technology through the analysis of experimental data during parameter and life cycle tests, including the effects of battery sizes, charge/discharge profiles and testing procedures, with special emphasis on the reduction of the internal resistance and the variation of peak power and cycle life.

  7. Results of recent NUPEC hydrogen related tests

    International Nuclear Information System (INIS)

    NUPEC has started NUPEC Containment Integrity project entitled open-quotes Proving Test on the Reliability for Reactor Containment Vesselclose quotes since June, 1987. This is the project for the term of twelve years sponsored by MITI (Ministry of International Trade and Industry, Japanese Government). Based on the test results, computer codes are verified and as the results of analysis and evaluation by the computer codes, containment integrity is to be confirmed. This paper indicates the results of hydrogen mixing and distribution test and hydrogen burning test. The NUPEC tests conducted so far suggest that hydrogen will be well mixed in the model containment vessel and the prediction by the computer code is in excellent agreement with the data. The NUPEC hydrogen burning test data is in good agreement with the FITS data at SNL that were obtained at the lower hydrogen concentration condition. New data bases have been added in the higher hydrogen concentration by the NUPEC data

  8. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  9. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  10. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  11. BWR Full Integral Simulation Test (FIST). Phase I test results

    International Nuclear Information System (INIS)

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report

  12. BWR Full Integral Simulation Test (FIST). Phase I test results

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, W S; Alamgir, M; Sutherland, W A

    1984-09-01

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report.

  13. Post-test analysis of lithium-ion battery materials at Argonne National Laboratory

    Science.gov (United States)

    Bareno, Javier; Dietz-Rago, Nancy; Bloom, Ira

    2014-03-01

    Electrochemical performance is often limited by surface and interfacial reactions at the electrodes. However, routine handling of samples can alter the very surfaces that are the object of study. Our approach combines standardized testing of batteries with sample harvesting under inert atmosphere conditions. Cells of different formats are disassembled inside an Argon glove box with controlled water and oxygen concentrations below 2 ppm. Cell components are characterized in situ, guaranteeing that observed changes in physicochemical state are due to electrochemical operation, rather than sample manipulation. We employ a complementary set of spectroscopic, microscopic, electrochemical and metallographic characterization to obtain a complete picture of cell degradation mechanisms. The resulting information about observed degradation mechanisms is provided to materials developers, both academic and industrial, to suggest new strategies and speed up the Research & Development cycle of Li-ion and related technologies. This talk will describe Argonne's post-test analysis laboratory, with an emphasis on capabilities and opportunities for collaboration. Cell disassembly, sample harvesting procedures and recent results will be discussed. This work was performed under the auspices of the U.S. Department of Energy, Office of Vehicle Technologies, Hybrid and Electric Systems, under Contract No. DE-AC02-06CH11357.

  14. Production LHC HTS power lead test results

    CERN Document Server

    Tartaglia, M; Fehér, S; Huang, Y; Orris, D F; Pischalnikov, Y; Rabehl, Roger Jon; Sylvester, C D; Zbasnik, J

    2005-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under "standard" and "extreme" operating conditions, and the stability of performance across thermal cycles.

  15. Content Validity Index and Intra- and Inter-Rater Reliability of a New Muscle Strength/Endurance Test Battery for Swedish Soldiers

    Science.gov (United States)

    Larsson, Helena; Tegern, Matthias; Monnier, Andreas; Skoglund, Jörgen; Helander, Charlotte; Persson, Emelie; Malm, Christer; Broman, Lisbet; Aasa, Ulrika

    2015-01-01

    The objective of this study was to examine the content validity of commonly used muscle performance tests in military personnel and to investigate the reliability of a proposed test battery. For the content validity investigation, thirty selected tests were those described in the literature and/or commonly used in the Nordic and North Atlantic Treaty Organization (NATO) countries. Nine selected experts rated, on a four-point Likert scale, the relevance of these tests in relation to five different work tasks: lifting, carrying equipment on the body or in the hands, climbing, and digging. Thereafter, a content validity index (CVI) was calculated for each work task. The result showed excellent CVI (≥0.78) for sixteen tests, which comprised of one or more of the military work tasks. Three of the tests; the functional lower-limb loading test (the Ranger test), dead-lift with kettlebells, and back extension, showed excellent content validity for four of the work tasks. For the development of a new muscle strength/endurance test battery, these three tests were further supplemented with two other tests, namely, the chins and side-bridge test. The inter-rater reliability was high (intraclass correlation coefficient, ICC2,1 0.99) for all five tests. The intra-rater reliability was good to high (ICC3,1 0.82–0.96) with an acceptable standard error of mean (SEM), except for the side-bridge test (SEM%>15). Thus, the final suggested test battery for a valid and reliable evaluation of soldiers’ muscle performance comprised the following four tests; the Ranger test, dead-lift with kettlebells, chins, and back extension test. The criterion-related validity of the test battery should be further evaluated for soldiers exposed to varying physical workload. PMID:26177030

  16. Low Emissions RQL Flametube Combustor Test Results

    Science.gov (United States)

    Chang, Clarence T.; Holdeman, James D.

    2001-01-01

    The overall objective of this test program was to demonstrate and evaluate the capability of the Rich-burn/Quick-mix/Lean-burn (RQL) combustor concept for HSR applications. This test program was in support of the Pratt & Whitney and GE Aircraft Engines HSR low-NOx Combustor Program. Collaborative programs with Parker Hannifin Corporation and Textron Fuel Systems resulted in the development and testing of the high-flow low-NOx rich-burn zone fuel-to-air ratio research fuel nozzles used in this test program. Based on the results obtained in this test program, several conclusions can be made: (1) The RQL tests gave low NOx and CO emissions results at conditions corresponding to HSR cruise. (2) The Textron fuel nozzle design with optimal multiple partitioning of fuel and air circuits shows potential of providing an acceptable uniform local fuel-rich region in the rich burner. (3) For the parameters studied in this test series, the tests have shown T3 is the dominant factor in the NOx formation for RQL combustors. As T3 increases from 600 to 1100 F, EI(NOx) increases approximately three fold. (4) Factors which appear to have secondary influence on NOx formation are P4, T4, infinity(sub rb), V(sub ref,ov). (5) Low smoke numbers were measured for infinity(sub rb) of 2.0 at P4 of 120 psia.

  17. The design and testing of an electrolyte destratification system applied to a 96 V Alco 2200 battery

    Science.gov (United States)

    Nowak, D.; Tomantschger, K.

    1984-01-01

    A pump system for electrolyte destratification in off-the-shelf conventional lead acid batteries was designed and tested at various operating temperatures. The system requires no modification to the battery case. The pump is inserted through small (3 to 4 mm) holes in the battery case top. The system applied was to a 96 V ALCO 2200 battery. The charge time was cut in half, the water loss was minimized, and overall efficiencies for the modified ALCO 2200 increased. Leakage problems were experienced in some modules due to the deterioration of the glue which attaches the air-lift pump manifolds onto the battery cover. The tests were performed on a 48 V system and extrapolated to a 96 V system.

  18. Strain-specific battery of tests for domains of mania: effects of valproate, lithium and imipramine

    Directory of Open Access Journals (Sweden)

    Shlomit Flaisher-Grinberg

    2010-04-01

    Full Text Available The lack of efficient animal models for bipolar disorder (BPD, especially for the manic pole, is a major factor hindering the research of its pathophysiology and the development of improved drug treatments. The present study was designed to identify an appropriate mouse strain for modeling some behavioral domains of mania and to evaluate the effects of drugs using this strain. The study compared the behavior of four strains: Black Swiss, C57Bl/6, CBA/J and A/J mice in a battery of tests that included spontaneous activity; sweet solution preference; light/dark box; resident-intruder; forced-swim and amphetamine-induced hyperactivity. Based on the ‘manic-like’ behavior demonstrated by the Black Swiss strain, the study evaluated the effects of the mood stabilizers valproate and lithium and of the antidepressant imipramine in the same tests using this strain. Results indicated that lithium and valproate attenuate the ‘manic-like’ behavior of Black Swiss mice whereas imipramine had no effects. These findings suggest that Black Swiss mice might be a good choice for modeling several domains of mania and distinguishing the effects of drugs on these specific domains. However, the relevance of the behavioral phenotype of Black Swiss mice to the biology of BPD is unknown at this time and future studies will investigate molecular differences between Black Swiss mice and other strains and asess the interaction between strain and mood stabilizing treatment.

  19. Automotive Battery Modelling and Management

    Directory of Open Access Journals (Sweden)

    N. M. Hammad

    2014-06-01

    Full Text Available The estimation of vehicle battery performance is typically addressed by testing the battery under specific operation conditions by using a model to represent the test results. Approaches for representing test results range from simple statistical models to neural networks to complex, physics-based models. Basing the model on test data could be problematical when testing becomes impractical with many years life time tests. So, real time estimation of battery performance, an important problem in automotive applications, falls into this area. In vehicles it is important to know the state of charge of the batteries in order to prevent vehicle stranding and to ensure that the full range of the vehicle operation is exploited. In this paper, several battery models have studied including analytical, electrical circuits, stochastic and electro- chemical models. Valve Regulated Lead Acid “VRLA” battery has been modelled using electric circuit technique. This model is considered in the proposed Battery Monitoring System “BMS”. The proposed BMS includes data acquisition, data analysis and prediction of battery performance under a hypothetical future loads. Based on these criteria, a microprocessor based BMS prototype had been built and tested in automotive Lab,. The tests show promising results that can be used in industrial applications

  20. Test battery for measuring the perception and recognition of facial expressions of emotion.

    OpenAIRE

    Wilhelm, Oliver; Hildebrandt, Andrea; Manske, Karsten; Schacht, Annekathrin; Sommer, Werner

    2014-01-01

    Despite the importance of perceiving and recognizing facial expressions in everyday life, there is no comprehensive test battery for the multivariate assessment of these abilities. As a first step toward such a compilation, we present 16 tasks that measure the perception and recognition of facial emotion expressions, and data illustrating each task's difficulty and reliability. The scoring of these tasks focuses on either the speed or accuracy of performance. A sample of 269 healthy young adu...

  1. Test Battery for Measuring the Perception and Recognition of Facial Expressions of Emotion

    OpenAIRE

    OliverWilhelm

    2014-01-01

    Despite the importance of the perception and recognition of facial expressions in everyday life there is no comprehensive test battery for the multivariate assessment of these abilities. As a first step towards such a compilation, we present 16 tasks for measuring the perception and the recognition of emotional expressions, along with their difficulty and reliability. The scoring of these tasks focuses on either the speed or accuracy of performance. A sample of 269 healthy young adults comple...

  2. Testing of the Eagle-Picher nickel-iron, the Globe ISOA lead-acid, and the Westinghouse nickel-iron battery subsystems in an electric-vehicle environment

    Science.gov (United States)

    Hewitt, R.; Bryant, J.

    1982-01-01

    Three full size developmental batteries were tested with electric vehicles; two nickel-iron batteries and a lead-acid battery. Constant speed and driving schedule tests were done on a chassis dynamometer. Several aspects of battery performance were evaluated for capacity, recharge efficiency, voltage response, and self discharge. Each of these three batteries exhibited some strengths and some weaknesses.

  3. Application of MicroLogixTM 1200 PLC in Battery OCV Test

    Institute of Scientific and Technical Information of China (English)

    Zhang Zhiyuan; Yang Yonggang; Zhao Xiaolong; Wu Fengming

    2004-01-01

    The application of MicroLogixTM 1200 PLC made by American AB Company in battery automatic production line located in Inner Mongolia Rare Earth Ovonic High-Power MH/Ni Battery Co., Ltd was introduced.OCV namely open circuit voltage could be somewhat different because of the build materials of negative electrode, positive electrode and electrolyte.So OCV test can check the voltage value of electrolyte filled cells and figure out if the value is within the process specification.MicroLogixTM 1200 relay output type PLC, DeviceNet communication card, variable speed driver, Panelview 1000 color touch screen and some other hardwares were chosen.Then programme by using RSLOGIX500 software, a flexible and skillful use of shift and XOR command in PLC system can make the equipments realize the high automation.Through DeviceNet network based on CAN and with the advantages of quick response and high reliability transmit the information to supervise and control master panel, the system with these components can successfully realize proceeding the battery OCV test and control.The equipments are running stably, locating and test accuracy satisfy the process request.

  4. Friction drive characterization breadboard: test results

    Science.gov (United States)

    Sedghi, B.; Lucuix, C.; Tortolani, J. M.; Brunetto, E.; Delrez, C.; Gabriel, E.

    2010-07-01

    The drive and bearing technologies have a major impact on the static and dynamic performance of steerable structures such as telescope and dome. Merging drive and bearing system into friction drive mechanical devices (bogie) can reduce the complexity and cost of the design. In the framework of ELT design study (European FP6) a breadboard test setup was realized to test and evaluate the static and dynamic behavior of such bogies. In this paper some of the characterization test results are presented. Characterization of the bogies and the setup structure in the frequency domain, quantification and measure of the most important parameters of the friction forces, the control of the bogies and the tracking performance of the test setup are among the main results discussed in this paper.

  5. Seismic testing of naturally aged exide EMP-13 station battery cells

    International Nuclear Information System (INIS)

    A sample of 27 year old lead acid storage batteries from the Shippingport Nuclear Power Station (Shippingport, PA) were tested on a shaker table. The intensity of the shaker tests reached the full capacity of the table. There were no sudden changes in output voltage for any of the seven cells during the stimulated earthquakes. Following the tests, however, the capacity of the cells was found to be sharply reduced. A number of cells were disassembled and examined. Internal components were found to be in poor condition, with loss of negative plate material and generalized corrosion

  6. Influence of Electrode Density on the Performance of Li-Ion Batteries: Experimental and Simulation Results

    OpenAIRE

    Jelle Smekens; Rahul Gopalakrishnan; Nils Van den Steen; Noshin Omar; Omar Hegazy; Annick Hubin; Joeri Van Mierlo

    2016-01-01

    Lithium-ion battery (LIB) technology further enabled the information revolution by powering smartphones and tablets, allowing these devices an unprecedented performance against reasonable cost. Currently, this battery technology is on the verge of carrying the revolution in road transport and energy storage of renewable energy. However, to fully succeed in the latter, a number of hurdles still need to be taken. Battery performance and lifetime constitute a bottleneck for electric vehicles as ...

  7. Old world monkeys compare to apes in the primate cognition test battery.

    Directory of Open Access Journals (Sweden)

    Vanessa Schmitt

    Full Text Available Understanding the evolution of intelligence rests on comparative analyses of brain sizes as well as the assessment of cognitive skills of different species in relation to potential selective pressures such as environmental conditions and social organization. Because of the strong interest in human cognition, much previous work has focused on the comparison of the cognitive skills of human toddlers to those of our closest living relatives, i.e. apes. Such analyses revealed that apes and children have relatively similar competencies in the physical domain, while human children excel in the socio-cognitive domain; in particular in terms of attention sharing, cooperation, and mental state attribution. To develop a full understanding of the evolutionary dynamics of primate intelligence, however, comparative data for monkeys are needed. We tested 18 Old World monkeys (long-tailed macaques and olive baboons in the so-called Primate Cognition Test Battery (PCTB (Herrmann et al. 2007, Science. Surprisingly, our tests revealed largely comparable results between Old World monkeys and the Great apes. Single comparisons showed that chimpanzees performed only better than the macaques in experiments on spatial understanding and tool use, but in none of the socio-cognitive tasks. These results question the clear-cut relationship between cognitive performance and brain size and--prima facie--support the view of an accelerated evolution of social intelligence in humans. One limitation, however, is that the initial experiments were devised to tap into human specific skills in the first place, thus potentially underestimating both true nonhuman primate competencies as well as species differences.

  8. Results of interlaboratory tests regarding TXRF

    International Nuclear Information System (INIS)

    Interlaboratory or intercomparison tests can be performed for proficiency testing of individual laboratories, for the certification of a special sample material and for the validation of a certain method. We participated in two interlaboratory tests in order to validate total reflection x-ray fluorescence analysis (TXRF). We used our results to evaluate TXRF and to compare it with other competing methods, particularly with respect of precision and accuracy. The first interlaboratory test was organized by IAEA (International Atomic Energy Agency, Vienna, Austria). As a candidate for reference material, a lichen (IAEA-336 Lichen) was distributed among 27 participants. In our laboratory, the powdered biogenic material was digested with nitric acid under high pressure and analyzed by TXRF. - The second interlaboratory test was organized by IRMM (Institute for Reference Materials and Measurements, Geel, Belgium). As a certified test sample with undisclosed values, a sediment (IMEP-14) was delivered to 220 laboratories. We digested the geogenic material again by nitric acid and additionally by hydrofluoric acid and analyzed it by TXRF. - In both test samples, six or eight different trace elements, respectively, were determined by TXRF with a content between 2 and 2000 mg/kg. Calibration was carried out by internal standardization. For that purpose, Ga or Se, respectively, was added as standard element. The measurement uncertainty of TXRF was estimated by the method of error propagation. In our paper we will report on the results of the two interlaboratory tests. It will be shown that TXRF is highly reliable for a correct determination of trace elements in biogenic and geogenic samples. It is competitive with the established methods of trace analyses which were involved in these tests and it is even superior to them in certain aspects. (author)

  9. BPX insulation irradiation program test results

    International Nuclear Information System (INIS)

    The toroidal field coil insulation for the Burning Plasma Experiment (BPX) is expected to receive a radiation dose of nearly 1010 rad and to withstand significant mechanical stresses. An irradiation test program was performed at the Idaho National Engineering Laboratory (INEL) using the Advanced Technology Reactor (ATR) for irradiations to doses on the order of 3 x 1010 rad. The flexure and shear strength with compression of commercially procured sheet material were reported earlier. A second series of tests has been performed to slightly higher dose levels with vacuum impregnated materials, glass strand material, and Spaulrad-S sheet samples. Vacuum impregnation with a Shell 9405 resin and 9470 hardener was used to produce bonded copper squares and flexure samples of both pure resin and resin with S-glass. A new test fixture was developed to test the bonded samples in shear without applied compression. The Spaulrad-S flexure samples demonstrated a loss of strength with irradiation, similar to previous results. The pure resin lost nearly all flexibility, while the S-glass-reinforced samples retained between 30% and 40% of the initial flexure strength. The S-glass strands showed a 30% loss of strength at the higher dose level when tested in tension. The bonded copper squares had a low room-temperature shear strength of approximately 17 MPa before irradiation, which was unchanged in the irradiated samples. Shear testing of unirradiated bonded copper squares with ten different types of surface treatment revealed that the low shear strength resulted from the polyurethane primer used. In the later series of test, the epoxy-based primers and DZ-80 from Ciba-Geigy did much better, with shear strengths on the order of 40 MPa. These samples also demonstrated a resistance to cryogenic shock. One irradiated bonded sample was tested up 10 210 MPa in compression, the limit of the test fixture, without failure

  10. Battery model for electrical power system energy balance

    Science.gov (United States)

    Hafen, D. P.

    1983-01-01

    A model to simulate nickel-cadmium battery performance and response in a spacecraft electrical power system energy balance calculation was developed. The voltage of the battery is given as a function of temperature, operating depth-of-charge (DOD), and battery state-of-charge. Also accounted for is charge inefficiency. A battery is modeled by analysis of the results of a multiparameter battery cycling test at various temperatures and DOD's.

  11. Results of 170 GHz gyrotron tests

    International Nuclear Information System (INIS)

    During the last few years the development of 170 GHz gyrotron for ITER have been under way. Sketchy description of experiment and test results of an improved design gyrotron with a depressed collector, are reported. The analysis of the phenomena causing the destruction of the output window is submitted. The projects for the following experiments are presented. The new 170 GHz/1 MW/50%/CW gyrotron with depressed collector and CVD diamond window was developed by GYCOM. This gyrotron was tested with BN window and then with diamond window. The gyrotron testing showed that practically all ITER requirements are satisfied except of pulse duration limited to that time by brick load arcing. Imperfection of arc protection system gave the possibility for arc-plasma to come to the window and destroy it. New loads have been created and tested at 140 GHz, with output gyrotron power Phf = 820 kW and the pulse duration T = 3.5 s. A new version of protection system has been developed and tested in experiment. The next gyrotron with modified electron gun has been manufactured. After first stage test, BN window will be replaced with new CVD diamond unit, which is assembling now. Testing of this gyrotron is planned to carry out in May 2002. (authors)

  12. Cone Penetrometer N Factor Determination Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2014-03-05

    This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to releate resistance measurements taken with the cone penetrometer to shear strength.

  13. Results from the Dafne high luminosity test

    International Nuclear Information System (INIS)

    In the second half of 2007 the Frascati DAΦNE collider has been upgraded in order to test an innovative collision scheme based on large Piwinski angle and providing for Crab-Waist compensation of the beam-beam interaction. In the following the main upgrade motivations are explained and the achieved results are presented and discussed.

  14. Battery performance monitoring by internal ohmic measurements: Application guidelines for stationary batteries. Final report

    International Nuclear Information System (INIS)

    Various routine inspections and checks offer a general indication of a battery's health and its state of charge. However, none of these routine checks provide definitive information about a battery's actual capacity. Consequently, capacity discharge tests have been and remain the traditional means by which adequate battery discharge tests have been and remain the traditional means by which adequate battery capacity is confirmed. Although technically prudent, the time and expense associated with capacity discharge testing is increasingly at odds with pressures to reduce operating and maintenance budgets. These pressures, in combination with new battery types that cannot be inspected by conventional mans, spurred development efforts for more cost-effective battery test techniques. Resulting advancements in battery monitoring equipment have produced new methods of evaluating battery health and reliability. The results presented here are based on a detailed research program to determine the degree of correlation between capacity and internal ohmic measurements. For each evaluated battery, internal ohmic measurements were recorded for individual cells prior to conducting a capacity discharge test of the battery. The discharge test results were then evaluated with respect to the internal ohmic measurements to determine the degree of correlation between capacity and internal ohmic measurements. The project goal was to obtain the necessary data to demonstrate the technology's value while also providing users with practical information about (1) the relationship between battery capacity and internal ohmic measurements, (2) how to use the test equipment in the field for best results, and (3) suggested guidelines for interpreting the measurements

  15. MIT 12 Tesla Coil test results

    International Nuclear Information System (INIS)

    Test results from the MIT 12 Tesla Coil experiment are presented. The coil was tested in the High Field Test Facility (HFTF) of the Lawrence Livermore National Laboratory in October 1984 and January 1985. The experiment measured the performance of an Internally Cooled, Cabled Superconductor (ICCS) of practical size, intended for use in magnetic fusion experiments. The MIT coil carried 15 kA at 11 T for 5 min with no sign of instability. A half turn length in a 10 T field was able to absorb a heat load in 4 msec of more than 200 mJ/cm3 of cable volume while carrying a current of 12 kA. The MIT coil successfully met the performance requirements of the Department of Energy's 12 Tesla Coil Program

  16. CLSM bleed water reduction test results

    International Nuclear Information System (INIS)

    Previous testing by BSRI/SRTC/Raytheon indicated that the CLSM specified for the Tank 20 closure generates about 6 gallons (23 liters) of bleed water per cubic yard of material (0.76 m3).1 This amount to about 10 percent of the total mixing water. HLWE requested that the CLSM mix be optimized to reduce bleed water while maintaining flow. Elimination of bleed water from the CLSM mix specified for High-Level Waste Tank Closure will result in waste minimization, time savings and cost savings. Over thirty mixes were formulated and evaluated at the on-site Raytheon Test Laboratory. Improved low bleed water CLSM mixes were identified. Results are documented in this report

  17. Results from the final focus test beam

    International Nuclear Information System (INIS)

    First experimental results from the Final Focus Test Beam (FFTB) are given in this report. The FFTB has been constructed as a prototype for the final focus system of a future TeV-scale electron-positron linear collider. The vertical dimension of the 47 GeV electron beam form the SLAC linac has been reduced at the focal point of the FFTB by a demagnification of 320 to a beam height of approximately 70 nanometers

  18. Automatic data processing of nondestructive testing results

    International Nuclear Information System (INIS)

    The ADP system for the documentation of inservice inspection results of nuclear power plants is described. The same system can be used during the whole operational life time of the plant. To make this possible the ADP system has to be independent of the type of hardware, data recording and software. The computer programs are made using Fortran IV programming language. The results of nondestructive testing are recorded in an inspection register by ADP methods. Different outputs can be utilized for planning, performance and reporting of inservice inspections. (author)

  19. Results from the STAR TPC system test

    International Nuclear Information System (INIS)

    A system test of various components of the Solenoidal Tracker at RHIC (STAR) detector, operating in concern, has recently come on-line. Communication between a major sub-detector, a sector of the Time Projection Chamber (TPC), and the trigger, data acquisition and slow controls systems has been established, enabling data from cosmic ray muons to be collected. First results from an analysis of the TPC data are presented. These include measurements of system noise, electronic parameters such as amplifier gains and pedestal values, and tracking resolution for cosmic ray muons and laser induced ionization tracks. A discussion on the experience gained in integrating the different components for the system test is also given

  20. Energy dissipation in Exosat tanks: Test results

    Science.gov (United States)

    Marce, J. L.; Torres, L.; Assemat, D.; Michel, S.

    1981-03-01

    Results of tests performed with inertia ratio and filling ratio scanning on Ariane tanks are presented. The Exosat launch requires the use of a fourth stage (P 0.7). The Exosat + P 0.7 assembly is spin stabilized with a spin rate of 50 rpm during transfer orbit. The unstable assembly is fitted with an active nutation damping system. To size this, it is necessary to know the time constant of nutation build up essentially due to fuel motion in the propane tanks and the hydrazine tank of Exosat. The major source of dissipation is the hydrazine tank for which an hysteresis phenomenon on diaphragm position was observed; the worst time constants of nutation build up, deduced from tests are 2.5 mn before P 0.7 and 1.9 mn after P 0.7 firing, taking into account the appropriate safety factors.

  1. Peeling-and-Coring-Machine Operator 529.886 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  2. Reliability and Responsiveness of the Movement Assessment Battery for Children--Second Edition Test in Children with Developmental Coordination Disorder

    Science.gov (United States)

    Wuang, Yee-Pay; Su, Jui-Hsing; Su, Chwen-Yng

    2012-01-01

    Aim: To examine the internal consistency, test-retest reliability, and responsiveness of the Movement Assessment Battery for Children--Second Edition (MABC-2) Test for children with developmental coordination disorder (DCD). Method: One hundred and forty-four Taiwanese children with DCD aged 6 to 12 years (87 males, 57 females) were tested on…

  3. Venetian Blind Assembler 6-39.551--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  4. Tomato Peeler (can. & preserv.) 529.887 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  5. Strain-Specific Battery of Tests for Domains of Mania: Effects of Valproate, Lithium and Imipramine

    OpenAIRE

    Flaisher-Grinberg, Shlomit; Einat, Haim

    2010-01-01

    The lack of efficient animal models for bipolar disorder (BPD), especially for the manic pole, is a major factor hindering the research of its pathophysiology and the development of improved drug treatments. The present study was designed to identify an appropriate mouse strain for modeling some behavioral domains of mania and to evaluate the effects of drugs using this strain. The study compared the behavior of four strains: Black Swiss, C57Bl/6, CBA/J and A/J mice in a battery of tests that...

  6. Strain-specific battery of tests for domains of mania: effects of valproate, lithium and imipramine

    OpenAIRE

    Shlomit Flaisher-Grinberg; Haim Einat

    2010-01-01

    The lack of efficient animal models for bipolar disorder (BPD), especially for the manic pole, is a major factor hindering the research of its pathophysiology and the development of improved drug treatments. The present study was designed to identify an appropriate mouse strain for modeling some behavioral domains of mania and to evaluate the effects of drugs using this strain. The study compared the behavior of four strains: Black Swiss, C57Bl/6, CBA/J and A/J mice in a battery of tests that...

  7. Dual color radiometer imagery and test results

    International Nuclear Information System (INIS)

    This paper presents a review of the technical characteristics of the Dual Color Radiometer and recent data and test results. The Dual Color Radiometer is a state-of-the-art device that provides simultaneous pixel to pixel registered thermal imagery in both the 3 to 5 and 8 to 12 micron regions. The device is unique in terms of its spatial and temperature resolution of less than 0.10 degrees C temperature and 0.10 milliradian spatial resolution. In addition, the device is tailored for use by the Automatic Target Recognizer (ATR) community

  8. Arc melter demonstration baseline test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process.

  9. Arc melter demonstration baseline test results

    International Nuclear Information System (INIS)

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process

  10. Influence of Electrode Density on the Performance of Li-Ion Batteries: Experimental and Simulation Results

    Directory of Open Access Journals (Sweden)

    Jelle Smekens

    2016-02-01

    Full Text Available Lithium-ion battery (LIB technology further enabled the information revolution by powering smartphones and tablets, allowing these devices an unprecedented performance against reasonable cost. Currently, this battery technology is on the verge of carrying the revolution in road transport and energy storage of renewable energy. However, to fully succeed in the latter, a number of hurdles still need to be taken. Battery performance and lifetime constitute a bottleneck for electric vehicles as well as stationary electric energy storage systems to penetrate the market. Electrochemical battery models are one of the engineering tools which could be used to enhance their performance. These models can help us optimize the cell design and the battery management system. In this study, we evaluate the ability of the Porous Electrode Theory (PET to predict the effect of changing positive electrode density in the overall performance of Li-ion battery cells. It can be concluded that Porous Electrode Theory (PET is capable of predicting the difference in cell performance due to a changing positive electrode density.

  11. Correlation between electrochemical characteristics and thermal stability of advanced lithium-ion batteries in abuse tests--short-circuit tests

    International Nuclear Information System (INIS)

    The shutdown function of a separator is an important factor in the safety of advanced lithium-ion batteries (ALB). When a separator without proper shutdown function is used, battery safety would depend on the thermal stability of electrode materials. Results show that thermal stability of a battery, contributed from both the anode and cathode, decreases noticeably after cycling. DSC shows that exothermicity from SEI decomposition and the reaction of the lithiated graphite and electrolyte around 140 deg. C increases as cycle number increase; main reason is the gradual thickening of passivation film, observed through three-electrode ac impedance measurements. DSC also shows a similar trend of exothermicity for LixCoO2 cathode. The lesser the amount of lithium (x-value) in LixCoO2, the larger the exothermicity and the lower the decomposition temperature. Using a three-electrode system to observe the changes of open-circuit potential in LixCoO2 cathode, thermal instability is a consequence of decreased lithium content as cycle increases

  12. Impaired or Not Impaired, That Is the Question: Navigating the Challenges Associated with Using Canadian Normative Data in a Comprehensive Test Battery That Contains American Tests.

    Science.gov (United States)

    Chevalier, Thérèse M; Stewart, Garth; Nelson, Monty; McInerney, Robert J; Brodie, Norman

    2016-08-01

    It has been well documented that IQ scores calculated using Canadian norms are generally 2-5 points lower than those calculated using American norms on the Wechsler IQ scales. However, recent findings have demonstrated that the difference may be significantly larger for individuals with certain demographic characteristics, and this has prompted discussion about the appropriateness of using the Canadian normative system with a clinical population in Canada. This study compared the interpretive effects of applying the American and Canadian normative systems in a clinical sample. We used a multivariate analysis of variance (ANOVA) to calculate differences between IQ and Index scores in a clinical sample, and mixed model ANOVAs to assess the pattern of differences across age and ability level. As expected, Full Scale IQ scores calculated using Canadian norms were systematically lower than those calculated using American norms, but differences were significantly larger for individuals classified as having extremely low or borderline intellectual functioning when compared with those who scored in the average range. Implications of clinically different conclusions for up to 52.8% of patients based on these discrepancies highlight a unique dilemma facing Canadian clinicians, and underscore the need for caution when choosing a normative system with which to interpret WAIS-IV results in the context of a neuropsychological test battery in Canada. Based on these findings, we offer guidelines for best practice for Canadian clinicians when interpreting data from neuropsychological test batteries that include different normative systems, and suggestions to assist with future test development. PMID:27246955

  13. Nickel cadmium battery evaluation, modeling, and application in an electric vehicle

    Science.gov (United States)

    Lynch, William Alfred

    A battery testing facility was set up in the battery evaluation laboratory. This system includes a set of current regulators which were fabricated in the UMASS. Lowell labs and a PC based data acquisition system. Batteries were charged or discharged at any rate within system ratings, and data including battery voltage, current, temperature and impedance were stored by a PC. STM5.140 type nickel-cadmium electric vehicle batteries were subjected to various test procedures using the battery testing facility. The results from these tests were used to determine battery characteristics. An electrical component battery model was also developed using the test data. The validity of the battery model was verified through experimental testing, and it was found to be accurate. Additionally, improved battery charging algorithms were developed which resulted in significant improvements in battery efficiency. Electric car operation with STM5.140 type of batteries was evaluated. Realistic road test data were analyzed experimentally and using the battery model. No battery abuse was found under EV driving conditions. The performance of the STM5.140 battery under abuse conditions was evaluated and it was found that it performs reasonably well under all abuse conditions tested. The model and test methodologies may be incorporated into complete electric vehicle models in order to assist in the design and operation of current and future electric vehicles.

  14. Results from the Cooler and Lead Tests

    International Nuclear Information System (INIS)

    The report presents the results of testing MICE spectrometer magnet current leads on a test apparatus that combines both the copper leads and the high temperature superconducting (HTS) leads with a single Cryomech PT415 cooler and liquid helium tank. The current is carried through the copper leads from 300 K to the top of the HTS leads. The current is then carried through the HTS leads to a feed-through from the vacuum space to the inside of a liquid helium tank. The experiment allows one to measure the performance of both cooler stages along with the performance of the leads. While the leads were powered we measured the voltage drops through the copper leads, through the HTS leads, through spliced to the feed-through, through the feed-through and through the low-temperature superconducting loop that connects one lead to the other. Measurements were made using the leads that were used in spectrometer magnet 1A and spectrometer magnet 2A. These are the same leads that were used for Superbend and Venus magnets at LBNL. The IL/A for these leads was 5.2 x 106 m-1. The leads turned out to be too long. The same measurements were made using the leads that were installed in magnet 2B. The magnet 2B leads had an IL/A of 3.3 x 106 A m-1. This report discusses the cooler performance and the measured electrical performance of the lead circuit that contains the copper leads and the superconducting leads. All of the HTS leads that were installed in magnet 2B were current tested using this apparatus.

  15. Norms for a neuropsychological test battery to diagnose dementia in the elderly: A study from Sri Lanka

    Directory of Open Access Journals (Sweden)

    Srikanth Srinivasan

    2015-01-01

    Full Text Available Aims: To pilot a neuropsychological battery for diagnosing dementia and provide normative scores in an elderly Sri Lankan sample. Materials and Methods: Consecutive subjects over the age of 60 yrs were administered tests assessing the individual domains of language, verbal episodic memory, visual perceptuospatial skills and executive functions in the Sinhala language. Results: There were a total of 230 subjects in the final sample. The mean age of the entire sample was 69 years, mean education level was 12 years and the sample comprised 53% female. One-month test-retest reliability ranged from 0.71 to 0.85 for the various tests. Most tests were significantly influenced by age and education level but not gender. The exceptions to this were some language subtests (repetition, grammar comprehension and word picture matching and two tests of executive functioning (maze completion and alternate target cancellation, which were uninfluenced by age. The subtests where ceiling performance was attained by almost all subjects were repetition, grammar comprehension and word picture matching from the language domain, dot position discrimination from the visuospatial domain and maze completion test from the executive function domain. Scores for various tests after stratifying subjects by age and educational level are given. Conclusions: The tests were well received and could provide a basis for cognitive profiling in similar settings elsewhere.

  16. Commissioning of ALFABURST: initial tests and results

    CERN Document Server

    Rajwade, Kaustubh; Lorimer, Duncan; Karastergiou, Aris; Werthimer, Dan; Siemion, Andrew; MacMahon, David; Cobb, Jeff; Williams, Christopher; Armour, Wes

    2016-01-01

    Fast Radio Bursts (FRBs) are apparently one-time, relatively bright radio pulses that have been observed in recent years. The origin of FRBs is currently unknown and many instruments are being built to detect more of these bursts to better characterize their physical properties and identify the source population. ALFABURST is one such instrument. ALFABURST takes advantage of the 7-beam Arecibo L-band Feed Array (ALFA) receiver on the 305-m Arecibo Radio Telescope in Puerto Rico, to detect FRBs in real-time at L-band (1.4 GHz). We present the results of recent on-sky tests and observations undertaken during the commissioning phase of the instrument. ALFABURST is now available for commensal observations with other ALFA projects.

  17. Field Lysimeter Test Facility: Second year (FY 1989) test results

    International Nuclear Information System (INIS)

    The Record of Decision associated with the Hanford Defense Waste Environmental Impact Statement (53 FR 12449-53) commits to an evaluation of the use of protective barriers placed over near-surface wastes. The barrier must protect against wind and water erosion and limit plant and animal intrusion and infiltration of water. Successful conclusion of this program will yield the necessary protective barrier design for near-surface waste isolation. This report presents results from the second year of tests at the FLTF. The primary objective of testing protective barriers at the FLTF was to measure the water budgets within the various barriers and assess the effectiveness of their designs in limiting water intrusion into the zone beneath each barrier. Information obtained from these measurements is intended for use in refining barrier designs. Four elements of water budget were measured during the year: precipitation, evaporation, storage, and drainage. Run-off, which is a fifth element of a complete water budget, was made negligible by a lip on the lysimeters that protrudes 5 cm above the soil surface to prevent run-off. A secondary objective of testing protective barriers at the FLTF was to refine procedures and equipment to support data collection for verification of the computer model needed for long-term projections of barrier performance. 6 refs

  18. Heaf test results after neonatal BCG.

    OpenAIRE

    Crawshaw, P. A.; Thomson, A H

    1988-01-01

    Heaf testing was carried out on 98 preschool Asian children who had received a BCG vaccination. A strongly positive Heaf reaction (grade 3) occurred in only two children. Heaf testing can still be used in tuberculosis screening after neonatal BCG.

  19. Development and Testing of an UltraBattery-Equipped Honda Civic

    Energy Technology Data Exchange (ETDEWEB)

    Donald Karner

    2012-04-01

    The UltraBattery retrofit project DP1.8 and Carbon Enriched project C3, performed by ECOtality North America (ECOtality) and funded by the U.S. Department of Energy (DOE) and the Advanced Lead Acid Battery Consortium (ALABC), are to demonstrate the suitability of advanced lead battery technology in Hybrid Electrical Vehicles (HEVs).

  20. [Predicting the success of occupational retraining using the occupational aptitude test battery].

    Science.gov (United States)

    Kreuzpointner, L

    2009-04-01

    In vocational retraining centres, a test battery including several performance tests is generally administered to assess the occupational aptitude of rehabilitants and to predict their success in occupational retraining. This paper presents the multiple regressions of a set of achievement scores on "grades of retraining" and "grades of final examination", respectively, concerning retraining to become an office management assistant. It was shown that only few variables are adequate to clarify a maximum of variance of the criterions. Four different regression models were identified; each of them could clarify about 25% of variance. Significant predictors were indicators for verbal skills and basic numeracy. In each model a measurement for nonverbal intelligence had to be taken into account as a suppressor variable. To put all in a nutshell, in order to predict the success of vocational retraining to become an office management assistant it is more important to focus on strengthening school knowledge than on general intelligence. PMID:19421942

  1. Analyzing Educational Testing Service Graduate Major Field Test Results

    Science.gov (United States)

    Thornton, Barry; Arbogast, Gordon

    2012-01-01

    The Educational Testing Service (ETS) created the Graduate Major Field Test in Business (GMFT-B) for MBA students. This test is administered to all MBA classes at Jacksonville University for the purpose of measuring student academic achievement and growth, as well as to assess educational outcomes. The test is given in the capstone course,…

  2. Vibration Durability Testing of Nickel Manganese Cobalt Oxide (NMC Lithium-Ion 18,650 Battery Cells

    Directory of Open Access Journals (Sweden)

    James Michael Hooper

    2016-01-01

    Full Text Available Electric vehicle (EV manufacturers are employing cylindrical format cells in the construction of the vehicles’ battery systems. There is evidence to suggest that both the academic and industrial communities have evaluated cell degradation due to vibration and other forms of mechanical loading. The primary motivation is often the need to satisfy the minimum requirements for safety certification. However, there is limited research that quantifies the durability of the battery and in particular, how the cells will be affected by vibration that is representative of a typical automotive service life (e.g., 100,000 miles. This paper presents a study to determine the durability of commercially available 18,650 cells and quantifies both the electrical and mechanical vibration-induced degradation through measuring changes in cell capacity, impedance and natural frequency. The impact of the cell state of charge (SOC and in-pack orientation is also evaluated. Experimental results are presented which clearly show that the performance of 18,650 cells can be affected by vibration profiles which are representative of a typical vehicle life. Consequently, it is recommended that EV manufacturers undertake vibration testing, as part of their technology selection and development activities to enhance the quality of EVs and to minimize the risk of in-service warranty claims.

  3. Energy Management of a Hybrid AC–DC Micro-Grid Based on a Battery Testing System

    Directory of Open Access Journals (Sweden)

    Bo Long

    2015-02-01

    Full Text Available Energy Recovery Battery Testing Systems (ERBTS plays an important role in battery manufacture. The conventional ERBTS configuration contains a fundamental transformer, and a bidirectional Direct Current (DC–DC and Alternating Current (AC–DC converter. All ERBTS are connected in parallel, thus constituting a special and complicated AC micro-grid system. Aiming at addressing their low energy recovery efficiency, complex grid-connected control algorithm issues for islanded detection, and complicated power circuit topology issues, a hierarchical DC-link voltage hybrid AC–DC micro-grid that contains composite energy storing devices is proposed. Moreover, an energy management optimal scheme for the proposed scheme is put forward. The system configuration of the proposed scheme is described in detail. Compared to the conventional scheme, the proposed scheme has the merits of simplified power circuit topology, no need for phase synchronous control, and much higher energy recovery efficiency and reliability. The validity and effectiveness of the proposed technique is verified through numerous experimental results.

  4. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test acknow...

  5. Haptic-2D: A new haptic test battery assessing the tactual abilities of sighted and visually impaired children and adolescents with two-dimensional raised materials.

    Science.gov (United States)

    Mazella, Anaïs; Albaret, Jean-Michel; Picard, Delphine

    2016-01-01

    To fill an important gap in the psychometric assessment of children and adolescents with impaired vision, we designed a new battery of haptic tests, called Haptic-2D, for visually impaired and sighted individuals aged five to 18 years. Unlike existing batteries, ours uses only two-dimensional raised materials that participants explore using active touch. It is composed of 11 haptic tests, measuring scanning skills, tactile discrimination skills, spatial comprehension skills, short-term tactile memory, and comprehension of tactile pictures. We administered this battery to 138 participants, half of whom were sighted (n=69), and half visually impaired (blind, n=16; low vision, n=53). Results indicated a significant main effect of age on haptic scores, but no main effect of vision or Age × Vision interaction effect. Reliability of test items was satisfactory (Cronbach's alpha, α=0.51-0.84). Convergent validity was good, as shown by a significant correlation (age partialled out) between total haptic scores and scores on the B101 test (rp=0.51, n=47). Discriminant validity was also satisfactory, as attested by a lower but still significant partial correlation between total haptic scores and the raw score on the verbal WISC (rp=0.43, n=62). Finally, test-retest reliability was good (rs=0.93, n=12; interval of one to two months). This new psychometric tool should prove useful to practitioners working with young people with impaired vision. PMID:26551596

  6. Modernisation in nondestructive testing for higher reliability of test results

    International Nuclear Information System (INIS)

    This proceedings volume contains 19 contributions on the following subjects: Concepts and basic developments for embedded multichannel test systems (H. Rieder); Novel ultrasonic converters - principles, production, applications (W. Gebhardt); Adaptation of theoretical models for higher reliability of test methods - the example of concrete (K.J. Langenberg et al.); Sound propagation phenomena as a basis for optimized test methods (H. Ernst et al.); New solutions to old problems - the potential of ultrasonic simulation as illustrated by the example of test bit optimisation (M. Spies); Laser-excited ultrasonic thickness measurement in pipe rolling plants (G.-J. Deppe); Modern concepts of automatic ultrasonic testing - the example of pipeline inspection (H. Willems et al.); A new concept for ultrasonic hollow axle testing (K. Matthies et al.); Ultrasonic methods in concrete testing (V. Schmitz); Auotmatic ultrasonic test facilities - throughput, interference, sensor systems (W.A.K. Deutsch et al.); Mechanised ultrasonic testing of thick-walled containers using phased arrays (N. Poertzgen et al.); Fast ultrasonic testing of pipes and rods using phased arrays (U. Schlengermann et al.); Improved weld testing with model-based inspection system optimisation (A. Erhard); Solutions for testing of austenitic mixed welds using phased arrays (G. Engl et al.); Exemplary innovative efficient inspection systems with phased arrays in industrial applications (R. Meier et al.); Image-based ultrasonic corrosion inspection of aircraft components (E. Grauvogl); Mechanised ultrasonic testing - training requirements (T. Heckel). Four papers can be found as separate records in this database

  7. U.S. Department of Energy Vehicle Technologies Program: Battery Test Manual For Plug-In Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen

    2014-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Renata M. Arsenault of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).

  8. Offline analysis of Direct Mount test results

    International Nuclear Information System (INIS)

    The tracking chamber design for the Direct Mount support system is discussed in this paper. It is called the Direct Mount design because the chambers are glued directly to the tank. This report continues the testing and study of the first Direct Mount prototype. The reader should keep in mind that our prototype assembly tests were done with materials on hand -- a mixture of tested and untested tubes, and a spacer constructed by gluing empty sleeves together, for a total of about 6 cm

  9. Supercritical CO2 test loop operation and first test results

    International Nuclear Information System (INIS)

    The DOE Office of Nuclear Energy is investigating advanced Brayton cycles for use with next generation nuclear power plants. The focus of this work is on the supercritical CO2 Brayton cycle which has the potential for high efficiency, and for reduced capital costs due to very compact turbomachinery. Sandia has fabricated and is operating a supercritical CO2 (S-CO2) test loop to investigate the key technology issues associated with this cycle. This loop is part of a multi-year phased development program to develop a megawatt (MW) class closed S-CO2 Brayton cycle to demonstrate the applicability of this cycle for DOE Gen-IV program. The current loop has been configured as both a compression loop and as simple heated but unrecuperated Brayton cycle. A second split-flow or re-compression Brayton cycle is currently under development that will use approximately 1 MW of heat to run the Brayton cycle. Early configurations of this split-flow Brayton cycle will be operational later this fiscal year. The key issues for this cycle include the fundamental issues of compressor fluid performance and system control near the critical point, but also the supporting technology issues of bearings, sealing technologies, and rotor windage losses which are also essential to achieving efficiency and cost objectives. These tests are providing the first measurements and information on these key supercritical CO2 power conversion systems questions. Important data for all these issues has been obtained. This report presents the major results of the testing by showing and comparing the measured compressor performance map with the predicted performance. The compression loop uses a ∼50 kWe motor driven compressor to spin a 37 mm OD compressor at design speeds up to 75,000 rpm with a pressure ratio of 1.8 and a flow rate of 3.53 kg/s for a compressor inlet condition of 305.3 K and 7690 kPa. The most recent configuration of this loop has added a small turbine and 260 kW of heater power is the

  10. Visual Working Memory and Perception Speed of 3- to 6-Year-Old Children Tested with a Matrix Film Battery Test

    Science.gov (United States)

    Pittorf, Martin L.; Lehmann, Wolfgang; Huckauf, Anke

    2014-01-01

    In this study the visual working memory (VWM) and perception speed of 60 children between the ages of three and six years were tested with an age-based, easy-to-handle Matrix Film Battery Test (reliability R?=?0.71). It was thereby affirmed that the VWM is age dependent (correlation coefficient r?=?0.66***) as expected. Furthermore, a significant…

  11. Ecotoxicological assessment of silica and polystyrene nanoparticles assessed by a multitrophic test battery.

    Science.gov (United States)

    Casado, Maria P; Macken, Ailbhe; Byrne, Hugh J

    2013-01-01

    The acute ecotoxicity of different diameters of silica and polyethyleneimine polystyrene (PS-PEI) nanoparticles (NPs) was assessed on a test battery of aquatic organisms representing different trophic levels. Daphnia magna, Thamnocephalus platyurus, Pseudokirchneriella subcapitata and Vibrio fischeri, were employed in a series of standard acute ecotoxicity tests and work was complemented with two cytotoxicological end points on a rainbow trout gonadal cell line (RTG-2). Physico-chemical characterization of the NPs was performed in the different test media employed, using dynamic light scattering (DLS) and zeta potentiometry. In contrast to silica NPs exposure, for which no effect was observed for concentrations up to 1000 μg ml(-1) for all in vivo aquatic organisms tested, significant toxicity was detected after exposure to PS-PEI NPs at concentrations from 0.40 μg ml(-1) to 416.5 μg ml(-1). Differing sensitivities for each NP diameter for the different organisms were observed as: P. subcapitata≥D. magna>T. platyurus>V. fischeri. The effects observed were dependent in some cases on the NP size, a higher effect being observed for the larger NPs. Finally, cytotoxicity studies showed an effect at the highest concentrations for both sets of NPs which was greater in the case of the PS-PEI NPs. However, as agglomeration and sedimentation of the nanoparticles was observed at these concentrations, the cytotoxicity studies were found not to be a reliable ecotoxicity test model. PMID:23202535

  12. Avco Lycoming emission and flight test results

    Science.gov (United States)

    Duke, L. C.

    1976-01-01

    The Avco Lycoming flight test program for reduced emissions was conducted to determine and document the lean fuel schedule limits for current production aircraft based on flight safety. Based on analysis of the emissions profile, Avco Lycoming proposed to evaluate the effect of leaner schedules in the idle/taxi, climb, and approach modes. These modes were selected as areas where it was felt that possible improvements could be made with the greatest improvement in cyclic emissions reduction. The fuel systems to produce these leaner stepped fuel schedules were tailored specifically for the flight test.

  13. Test beam results of lead tungstate matrices

    International Nuclear Information System (INIS)

    Different lead tungstate matrices with avalanche photodiode readout have been tested in electron and pion beam at CERN. In the H4 beam, a 7 x 7 crystal matrix response has been studied with electrons of 15 to 150 GeV. Crystals (about 23 cm long and pointing shape) came from different producers. An energy resolution of about 0.6% at 100 GeV has been obtained. On the other hand, a 3 x 3 crystals matrix equipped with the first prototype of a complete electronic readout chain (fast shaping, full dynamic range) has been tested in the X3 beam. (orig.)

  14. Testing ESL sociopragmatics development and validation of a web-based test battery

    CERN Document Server

    Roever, Carsten; Elder, Catherine

    2014-01-01

    Testing of second language pragmatics has grown as a research area but still suffers from a tension between construct coverage and practicality. In this book, the authors describe the development and validation of a web-based test of second language pragmatics for learners of English. The test has a sociopragmatic orientation and strives for a broad coverage of the construct by assessing learners'' metapragmatic judgments as well as their ability to co-construct discourse. To ensure practicality, the test is delivered online and is scored partially automatically and partially by human raters.

  15. All-electrostatic split LEBT test results

    International Nuclear Information System (INIS)

    An all-electrostatic LEBT for an RFQ has been assembled and tested with beam. The LEBT includes two quasi-einzel lenses, allowing a wider range of Twiss parameters to be accommodated, and the lenses are split into quadrants, allowing electrical steering of the beam. Moreover, mechanical steering by moving the entire LEBT with a special low-friction vacuum joint was also demonstrated. The LEBT was tested with unanalyzed protons from an RF-driven bucket source by measuring the beam directly and by measuring the transmission through a subsequent RFQ as a function of LEBT electrode parameters. Agreement between calculated LEBT beam characteristics and actual measured values is excellent. This LEBT offers fully unneutralized beam transport with steering and two-knob control of exit Twiss parameters, and can be applied to negative hydrogen as well as proton beams. (author)

  16. Results from ATLAS Calorimeter Combined Test Beam

    CERN Document Server

    Tarrade, F

    2007-01-01

    Beam tests of combinations of ATLAS calorimeters have been performed both for the barrel and end cap parts. During a combined test beam in summer 2004 a slice of the ATLAS barrel detector - including all detector sub systems from the inner tracker, the calorimetry to the muon system - was exposed to particle beams (electrons, pions, photons, muons) with different energies (1GeV to 350GeV). The aim was to study the combined performance of the different detector sub systems in ATLAS-like conditions. We will present the electronics calibration scheme of the electromagnetic calorimeter and its implementation. The following studies on the combined testbeam data have been performed and will be presented: performance of the electromagnetic calorimetry down to very low energies (> GeV), photon reconstruction including converted photons and position measurements using the very precise ATLAS tracker and the electromagnetic calorimeter. These measurements have been compared to Monte Carlo simulations showing the good de...

  17. Results of final focus test beam

    OpenAIRE

    Alexandrof, V.A.; Balakin, V.; Mikhailichenko, A..; Flottmann, K.; Peters, F.; Voss, G.A.; Bharadwaj, V.; Halling, M.; Buon, J.; Jeanjean, J.; LeDiberder, F.; Lepeltier, V.; Puzo, P.; Heimlinger, G.; Settles, R.

    1995-01-01

    The beam experiments of Final Focus Test Beam (FFTB) started in September 1993 at SLAC, and have produced a 1.7 μm×75 nm spot of 46 GeV electron beam. A number of new techniques involving two nanometer spot-size monitors have been developed. Several beam diagnostic/tuning schemes are applied to achieve and maintain the small spot. This experiment opens the way toward the nanometer world for future linear colliders

  18. Results of workplace drug testing in Norway

    Directory of Open Access Journals (Sweden)

    Hilde Marie Erøy Lund

    2011-12-01

    Full Text Available Workplace drug testing is less common in Norway than in many other countries. During the period from 2000-2006, 13469 urine or blood samples from employees in the offshore industry, shipping companies and aviation industry were submitted to the Norwegian Institute of Public Health for drug testing. The samples were analysed for benzodiazepines, illicit drugs, muscle relaxants with sedating properties, opioids and z-hypnotics. In total, 2.9% of the samples were positive for one or more substances. During the study period the prevalence decreased for morphine (from 1.9% to 1.1% and increased for amphetamine (from 0.04% to 0.6%, clonazepam (from 0% to 0.1%, methamphetamine (from 0.04% to 0.6%, nitrazepam (from 0% to 0.4% and oxazepam (from 0.5% to 1.3% (p<0.05. There was no significant change in prevalence for the other substances included in the analytical programme. Illicit drugs were significantly associated with lower age (OR: 0.93, p<0.05. This study found low prevalence of drugs among employees in companies with workplace drug testing programmes in Norway.

  19. Evaluation of vinyl laurate in a battery of in vitro and in vivo tests for genotoxicity.

    Science.gov (United States)

    van Acker, Frédérique; Messinger, Horst; Bär, Albert

    2015-06-01

    Vinyl laurate is a potential residual monomer in chewing gum base formulated with polyvinyl acetate vinyl laurate copolymer (PVAcVL). The genotoxic potential of vinyl laurate was examined in a battery of in vitro and in vivo genotoxicity tests. Vinyl laurate was not mutagenic in Ames tests. In addition, it was not mutagenic in the HPRT mutation assay in L5178Y cells. An in vitro mammalian chromosome aberration assay performed in CHO cells was equivocal. Vinyl laurate and/or its metabolites were not clastogenic in the mouse bone marrow micronucleus test. Kinetic data indicate that VL is metabolised to acetaldehyde and lauric acid. Both metabolites are well known and have been studied previously. Model calculations show, that any exposure to acetaldehyde from the consumption of PVAcVL containing chewing gum will remain far below levels of acetaldehyde exposure from food in which acetaldehyde occurs naturally. Direct exposure to VL will primarily be at the site of entry. The lack of toxicity in a 90-day repeated dose toxicity test, performed with VL doses up to approximately 3000 times higher than the maximal VL intake from the consumption of a typical piece of chewing gum, demonstrates a high safety margin. PMID:25445001

  20. Peabody Picture Vocabulary Test-Revised and Luria-Nebraska Neuropsychological Battery for Children: Intercorrelations for Normal Youngsters.

    Science.gov (United States)

    Quattrocchi, Mary M.; Golden, Charles J.

    1983-01-01

    The relationship between scores on the Peabody Picture Vocabulary Test-Revised (PPVT-R) and Luria-Nebraska Neuropsychological Battery for Children was examined utilizing 86 normal children, including 55 females and 31 males from middle-class families. Significant relationships were predicted between the PPVT-R and the receptive scale on the…

  1. TECHNICAL REPORT ON STANDARDIZATION OF THE GENERAL APTITUDE TEST BATTERY, GENERAL WORKING POPULATION NORMS STUDY FOR PUERTO RICO.

    Science.gov (United States)

    Bureau of Employment Security (DOL), Washington, DC.

    THE POSSIBILITY OF PREDICTIVE ERROR WHEN APPLYING U.S. MAINLAND NORMS FOR THE GENERAL APTITUDE TEST BATTERY TO THE EMPLOYMENT COUNSELING AND SELECTION PROCESS IN PUERTO RICO, PROMPTED A STUDY TO ESTABLISH LOCAL NORMS FOR THE SPANISH LANGUAGE VERSION, BATERIA GENERAL DE PRUEBAS DE APTITUD. A STRATIFIED QUOTA SAMPLE OF 1,500 PERSONS WAS SELECTED…

  2. PBF severe fuel damage scoping test. Test results report

    International Nuclear Information System (INIS)

    This report presents a comprehensive evaluation of the Severe Fuel Damage Scoping test (SFD-ST) performed in the Power Burst facility (PBF) at the Idaho National Engineering Laboratory. The test is part of an internationally sponsored light water reactor severe accident research program, initiated by the US Nuclear Regulatory Commission. The experiment was the first of four, in-pile, multifuel rod tests performed in the PBF. The SFD-ST fuel bundle comprised 32, 0.9-m long, trace-irradiated (91 MWd/T) fuel rods. The bundle was surrounded by an insulating shroud, with the region maintained at a pressure of 7 MPa. The experiment consisted of a transient in which the inlet coolant flow to the test bundle was reduced to 16 g/s, and the nuclear power increased, until the peak temperature approached fuel melting. The ∼3 h transient was terminated by scram of the reactor, with the inlet coolant reflooding and cooling the bundle to saturation temperature within 8 min. The overall technical objective of the test was to contribute to the understanding of fuel bundle dyanmics, and the related hydrogen and fission product behavior, during a high temperature transient. The report provides a description of the major observed phenomena. Interpretation of the test was based upon the response of on-line instruments, posttest fission product sample analysis, nondestructive and destructive postirradiation examination of the fuel bundle, and a calculational study using the Severe Core Damage Analysis Package (SCDAP)

  3. Results from some anode wire aging tests

    International Nuclear Information System (INIS)

    Using twin setups to test anode wire aging in small gas avalanche tubes, a variety of different gas mixtures were tried and other parameters were varied to study their effects upon the gain drop, nomalized to charge transfer: - 1/Q dI/I. This was found to be quite sensitive to the purity of the gases, and also sensitive to the nominal gain and the gas flow rate. The wire surface material can also significantly affect the aging, as can additives, such as ethanol or water vapor. Certain gas mixtures have been found to be consistent with zero aging at the sensitivity level of this technique

  4. Test Results of a Phi Monitoring System

    CERN Document Server

    Figueroa, Carlos; Burgos, C; Ferrrando, A; Matorras, Francisco; Molinero, Antonio; Rodriguo, T; Shvachkin, V

    1997-01-01

    The development and tests of a Phi monitoring system prototype designed for the CMS Muon Spectrometer alignment are described. The system, using a sweeping laser beam, defines a light reference plane to be used for the continuous monitoring of the Muon detectors. The performance of the system in the Laboratory was satisfactory. It showed good stability and linearity response behaviour. With the appropriate selection of components it can monitor large range position shifts ( up to 1-2 cm) with good accuracy at long distances ( ~ 60 mu accuracy at 10 m).

  5. OPERA Resistive Plate Chambers underground test results

    Energy Technology Data Exchange (ETDEWEB)

    Bergnoli, A. [Padova University and INFN, Padova (Italy); Brugnera, R. [Padova University and INFN, Padova (Italy); Candela, A. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); Carrara, E. [Padova University and INFN, Padova (Italy); Ciesielski, R. [Padova University and INFN, Padova (Italy); Dal Corso, F. [Padova University and INFN, Padova (Italy); Degli Esposti, L. [Bologna University and INFN, Bologna (Italy); Di Giovanni, A. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); D' Incecco, M. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); Di Troia, C. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Dusini, S. [Padova University and INFN, Padova (Italy); Fanin, C. [Padova University and INFN, Padova (Italy); Felici, G. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Gambarara, A. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Garfagnini, A. [Padova University and INFN, Padova (Italy); Gatta, M.; Grianti, F. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Gustavino, C.; Lindozzi, M. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); Longhin, A. [Padova University and INFN, Padova (Italy)]. E-mail: longhin@pd.infn.it; Mengucci, A. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Monacelli, P. [L' Aquila University and INFN, l' Aquila (Italy)]|[INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); Paoloni, A. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Stanco, L. [Padova University and INFN, Padova (Italy); Tatananni, E. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); Terranova, F.; Spinetti, M. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Stipcevic, M.; Sugonyaev, V. [Rudjer Boskovic Institute (IRB), Zagreb (Croatia); Terminiello, L.; Ventura, M.; Votano, L. [INFN Laboratori Nazionali di Frascati, Frascati (Italy)

    2006-08-15

    The OPERA experiment [M. Guler et al., CERN/SPSC 2000-028, SPSC/P318, LNGS P25/2000, July 10, 2000; M. Guler et al., CERN/SPSC 2001-025, SPSC/M668, LNGS-EXP 30/2001 Add. 1/01, August 21, 2001] will study {nu}{sub {mu}}->{nu}{sub {tau}} oscillations through {tau} appearance on the 732 Km long CERN to Gran Sasso baseline. The magnet yokes of the two muon spectrometers are instrumented with 44 layers of high resistivity bakelite Resistive Plate Chambers (RPCs) operated in streamer mode. Each layer covers about 70 m{sup 2}. Four RPC planes were instrumented and the first tests were performed confirming a good behaviour of the installed RPCs in terms of intrinsic noise and operating currents. The measured noise maps agree with those obtained in the extensive quality tests performed at surface. Counting rates are below 20 Hz/m{sup 2}. Single an multiple cosmic muon tracks were also reconstructed. The estimated efficiency is close to the geometrical limit and the very first measurements of the absolute and differential muon flux are in agreement with expectations.

  6. OPERA Resistive Plate Chambers underground test results

    International Nuclear Information System (INIS)

    The OPERA experiment [M. Guler et al., CERN/SPSC 2000-028, SPSC/P318, LNGS P25/2000, July 10, 2000; M. Guler et al., CERN/SPSC 2001-025, SPSC/M668, LNGS-EXP 30/2001 Add. 1/01, August 21, 2001] will study νμ->ντ oscillations through τ appearance on the 732 Km long CERN to Gran Sasso baseline. The magnet yokes of the two muon spectrometers are instrumented with 44 layers of high resistivity bakelite Resistive Plate Chambers (RPCs) operated in streamer mode. Each layer covers about 70 m2. Four RPC planes were instrumented and the first tests were performed confirming a good behaviour of the installed RPCs in terms of intrinsic noise and operating currents. The measured noise maps agree with those obtained in the extensive quality tests performed at surface. Counting rates are below 20 Hz/m2. Single an multiple cosmic muon tracks were also reconstructed. The estimated efficiency is close to the geometrical limit and the very first measurements of the absolute and differential muon flux are in agreement with expectations

  7. Fort St. Vrain hot functional test results

    International Nuclear Information System (INIS)

    A description is given of Fort St. Vrain hot functional tests performed to evaluate the initial nonnuclear performance of the primary coolant system and the associated effects on the various internal components of the reactor vessel and primary coolant system. The components included the twelve steam generator modules, the four helium circulators, the PCRV thermal barrier and liner coolant system, the helium purification system, and the primary and secondary closures at each of the PCRV penetrations. Additional objectives included analysis of the parallel operation of the four helium circulators and the performance of several circulator start/stop transients under various conditions of primary coolant temperature and pressure. Vibration and acoustical phenomena within the vessel were measured, recorded, and compared to theoretical analyses; a verification of reverse flow in the shutdown loop steam generator during one loop operation was performed; the PCRV was again observed for its structural response to internal pressure; and comparisons were made relative to data recorded during the initial pressure test completed in July 1971. (U.S.)

  8. Achieving geodetic motion for LISA test masses: ground testing result

    OpenAIRE

    Carbone, L; Cavalleri, A.; Dolesi, R; Hoyle, C. D.; Hueller, M.; Vitale, S; Weber, W. J.

    2003-01-01

    The low-frequency resolution of space-based gravitational wave observatories such as LISA (Laser Interferometry Space Antenna) hinges on the orbital purity of a free-falling reference test mass inside a satellite shield. We present here a torsion pendulum study of the forces that will disturb an orbiting test mass inside a LISA capacitive position sensor. The pendulum, with a measured torque noise floor below 10 fNm/sqrt{Hz} from 0.6 to 10 mHz, has allowed placement of an upper limit on senso...

  9. Uncertainty in in-place filter test results

    International Nuclear Information System (INIS)

    Some benefits of accounting for uncertainty in in-place filter test results are explored. Information the test results provide relative to system performance acceptance limits is evaluated in terms of test result uncertainty. An expression for test result uncertainty is used to estimate uncertainty in in-place filter tests on an example air cleaning system. Modifications to the system test geometry are evaluated in terms of effects on test result uncertainty

  10. Conductance testing compared to traditional methods of evaluating the capacity of valve-regulated lead/acid batteries and predicting state-of-health

    Energy Technology Data Exchange (ETDEWEB)

    Feder, D.O. (Electrochemical Energy Storage Systems, Inc., Madison, NJ (United States)); Croda, T.G. (Sprint, Long Distance Div., Burlingame, CA (United States)); McShane, S.J.; Hlavac, M.J. (Midtronics, Inc., Willowbrook, IL (United States)); Champlin, K.S.

    1992-09-15

    Recently, timed discharge capacity tests were performed on 336 individual valve-regulated lead/acid cells in a telecommunications power system. The results were compared with traditional methods of determining cell health (i.e., float voltage, open-circuit voltage, and calculated specific gravity). At the same time, conductance measurements were taken, and these results were also compared to the results of the timed discharge capacity tests. Data will be presented which show that traditional methods indicate almost no correlation to timed discharge capacity testing. Conductance test data will be presented which show a very nearly linear correlation. Based on this correlation, these results indicate that conductance testing can provide users of valve-regulated lead/acid batteries with a valuable predictive tool for determining the state-of-health of individual cells. (orig.).

  11. Field Cone Penetration Tests with Various Penetration Rates - Test Results

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    The test site is located at Nordre Ringgade near the town called Dronninglund in the northern Jutland in Denmark. The site area is relatively flat, and was chosen because it has a size of approximately 3 ha and contains a relatively thick deposit of silty soils. Furthermore the groundwater was...

  12. A comparison of battery testing protocols: Those used by the U.S. advanced battery consortium and those used in China

    Science.gov (United States)

    Robertson, David C.; Christophersen, Jon P.; Bennett, Taylor; Walker, Lee K.; Wang, Fang; Liu, Shiqiang; Fan, Bin; Bloom, Ira

    2016-02-01

    Two testing protocols, QC/T 743 and those used by the U.S. Advanced Battery Consortium (USABC), were compared using cells based on LiFePO4/graphite chemistry. Differences in the protocols directly affected the data and the performance decline mechanisms deduced from the data. In all cases, the rate of capacity fade was linear with time. Overall, the testing protocols produced very similar data when the testing conditions and metrics used to define performance were similar. The choice of depth of discharge and pulse width had a direct effect on the apparent rate of resistance increased and estimated cell life. At greater percent depth of discharge (%DOD) and pulse width, the estimated life was shorter that at lower %DOD and shorter pulse width. This indicates that cells which were at the end of life based on the USABC protocol were not at end of life based on the QC/T 743 protocol by a large margin.

  13. Results from DR and Instrumentation Test Facilities

    CERN Document Server

    Urakawa, Junji

    2005-01-01

    The KEK Accelerator Test Facility (ATF) is a 1.3GeV storage ring capable of producing ultra-low emittance electron beams and has a beam extraction line for ILC R&D. The ATF has proven to be an ideal place for researches with small, stable beams. 2x1010 single bunch and low current 20 bunch-train with 2.8nsec bunch spacing have been extracted to develop Nano-Cavity BPM’s, FONT, Nano Beam Orbit handling (FEATHER), Optical Diffraction Radiation (ODR) monitor, a precision multi-bunch laser-based beam profile monitor and polarized positron beam generation via backward-Compton scattering by the international collaboration. A set of three cavity BPM's is installed in the ATF extraction line on a set of extremely stiff supports. The KEK group installed another set of three BPM's, with their own support mechanism. The full set of 6 will prove extremely useful. In the DR (Damping Ring), we are researching the fast ion instability, micro-wave instability with four sets of damping wiggler and developing pul...

  14. Airlift recirculation well test results - Southern sector

    International Nuclear Information System (INIS)

    Chlorinated solvents used in the A and M-Areas at the Savannah River Site (SRS) from 1952--1982 have contaminated the groundwater under the site. A plume of groundwater contaminated with trichloroethylene (TCE) and perchloroethylene (PCE) in the Lost Lake aquifer is moving generally southward with the natural flow of groundwater. To comply with the requirements of the current SCDHEC Part B Permit, a series of wells is being installed to contain and treat the plume. Airlift Recirculation Wells (ARW) are a new and innovative technology with potential for more cost effective implementation than conventional pump and treat systems. Two Airlift Recirculation Wells have been installed and tested to quantify performance parameters needed to locate a line of these wells along the leading edge of the contaminant plume. The wells proved to be very sensitive to proper development, but after this requirement was met, performance was very good. The Zone of Capture has been estimated to be within a radius of 130--160 ft. around the wells. Thus a line of wells spaced at 250 ft. intervals could intercept the contaminant plume. At SSR-012, TCE was stripped from the groundwater at approximately 1.2 lb./day. The longer term effect of the recirculation wells upon the plume and the degree of recirculation within the aquifer itself will require additional data over a longer time period for an accurate review. Data collection is ongoing

  15. Household batteries: Evaluation of collection methods

    Energy Technology Data Exchange (ETDEWEB)

    Seeberger, D.A.

    1992-12-31

    While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household batteries are discussed.

  16. Household batteries: Evaluation of collection methods

    Energy Technology Data Exchange (ETDEWEB)

    Seeberger, D.A.

    1992-01-01

    While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household batteries are discussed.

  17. Comparison of Physical Fitness Parameters with EUROFIT Test Battery of Male Adolescent Soccer Players and Sedentary Counterparts

    Directory of Open Access Journals (Sweden)

    Özgür ERİKOĞLU

    2015-09-01

    Full Text Available The aim of this study was to compare physical fitness parameters of male adolescent soccer players and sedentary counterparts. A total of 26 male adolescents participated in this study voluntarily: Active soccer players (n: 3, age x : 13,00 ± 0,00 and sedentary counterparts (n: 13, age x :12,92 ± 0,75. The EUROFIT test battery was used to determine physical fitness. The test battery includes body height and weight measurements, touching the discs, flamingo balan ce, throwing health ball, vertical jumping, sit and reach, sit - up for 30 s, 20 meter sprint run, and 20 meter shuttle run tests. Data were analyzed by Mann Whitney U test. Significance was defined as p.05. In conclusion, children who do sports are more successful on most of the fitness parameters than sedentary children.

  18. Achieving geodetic motion for LISA test masses: ground testing result

    CERN Document Server

    Carbone, L; Dolesi, R; Hoyle, C D; Hüller, M; Vitale, S; Weber, W J

    2003-01-01

    The low-frequency resolution of space-based gravitational wave observatories such as LISA (Laser Interferometry Space Antenna) hinges on the orbital purity of a free-falling reference test mass inside a satellite shield. We present here a torsion pendulum study of the forces that will disturb an orbiting test mass inside a LISA capacitive position sensor. The pendulum, with a measured torque noise floor below 10 fNm/sqrt{Hz} from 0.6 to 10 mHz, has allowed placement of an upper limit on sensor force noise contributions, measurement of the sensor electrostatic stiffness at the 5% level, and detection and compensation of stray DC electrostatic biases at the mV level.

  19. INTRAVAL test case 1b - modelling results

    International Nuclear Information System (INIS)

    This report presents results obtained within Phase I of the INTRAVAL study. Six different models are fitted to the results of four infiltration experiments with 233U tracer on small samples of crystalline bore cores originating from deep drillings in Northern Switzerland. Four of these are dual porosity media models taking into account advection and dispersion in water conducting zones (either tubelike veins or planar fractures), matrix diffusion out of these into pores of the solid phase, and either non-linear or linear sorption of the tracer onto inner surfaces. The remaining two are equivalent porous media models (excluding matrix diffusion) including either non-linear sorption onto surfaces of a single fissure family or linear sorption onto surfaces of several different fissure families. The fits to the experimental data have been carried out by Marquardt-Levenberg procedure yielding error estimates of the parameters, correlation coefficients and also, as a measure for the goodness of the fits, the minimum values of the χ2 merit function. The effects of different upstream boundary conditions are demonstrated and the penetration depth for matrix diffusion is discussed briefly for both alternative flow path scenarios. The calculations show that the dual porosity media models are significantly more appropriate to the experimental data than the single porosity media concepts. Moreover, it is matrix diffusion rather than the non-linearity of the sorption isotherm which is responsible for the tailing part of the break-through curves. The extracted parameter values for some models for both the linear and non-linear (Freundlich) sorption isotherms are consistent with the results of independent static batch sorption experiments. From the fits, it is generally not possible to discriminate between the two alternative flow path geometries. On the basis of the modelling results, some proposals for further experiments are presented. (author) 15 refs., 23 figs., 7 tabs

  20. Test results of a prototype dielectric microcalorimeter

    Science.gov (United States)

    Pfafman, T. E.; Silver, E.; Labov, S.; Beeman, J.; Goulding, F.; Hansen, W.; Landis, D.; Madden, N.

    1990-01-01

    The initial development work on a dielectric microcalorimeter is presented. It focuses on the dielectric properties of the ferroelectric material KTa(1-x)Nb(x)O3 (KTN). Measurements of the temperature dependent dielectric constant are given together with the first alpha particle detection results from a prototype composite microcalorimeter operating at 1.3 K. A nonthermal mechanism for detecting 6 MeV alpha particles in a monolithic KTN sample is also reported.

  1. Crewed Space Vehicle Battery Safety Requirements

    Science.gov (United States)

    Jeevarajan, Judith A.; Darcy, Eric C.

    2014-01-01

    This requirements document is applicable to all batteries on crewed spacecraft, including vehicle, payload, and crew equipment batteries. It defines the specific provisions required to design a battery that is safe for ground personnel and crew members to handle and/or operate during all applicable phases of crewed missions, safe for use in the enclosed environment of a crewed space vehicle, and safe for use in launch vehicles, as well as in unpressurized spaces adjacent to the habitable portion of a space vehicle. The required provisions encompass hazard controls, design evaluation, and verification. The extent of the hazard controls and verification required depends on the applicability and credibility of the hazard to the specific battery design and applicable missions under review. Evaluation of the design and verification program results shall be completed prior to certification for flight and ground operations. This requirements document is geared toward the designers of battery systems to be used in crewed vehicles, crew equipment, crew suits, or batteries to be used in crewed vehicle systems and payloads (or experiments). This requirements document also applies to ground handling and testing of flight batteries. Specific design and verification requirements for a battery are dependent upon the battery chemistry, capacity, complexity, charging, environment, and application. The variety of battery chemistries available, combined with the variety of battery-powered applications, results in each battery application having specific, unique requirements pertinent to the specific battery application. However, there are basic requirements for all battery designs and applications, which are listed in section 4. Section 5 includes a description of hazards and controls and also includes requirements.

  2. Battery System Modeling for a Military Electric Propulsion Vehicle with a Fault Simulation

    Directory of Open Access Journals (Sweden)

    Hyeongcheol Lee

    2013-10-01

    Full Text Available This paper describes the development process and results of a battery system model with a fault simulation for electric propulsion vehicles. The developed battery system model can be used to verify control and fault diagnosis strategies of the supervisory controller in an electric propulsion vehicle. To develop this battery system model, three sub-models, including a battery model, a relay assembly model, and a battery management system (BMS model, are connected together like in the target real battery system. Comparison results between the real battery system hardware and the battery system model show a similar tendency and values. Furthermore, the fault injection test of the model shows that the proposed battery system model can simulate a failure situation consistent with a real system. It is possible for the model to emulate the battery characteristics and fault situation if it is used in the development process of a BMS or for supervisory control strategies for electric propulsion systems.

  3. Development of USES Specific Aptitude Test Battery S-111R84 for Airframe-and-Powerplant Mechanic (Aircraft-Aerospace Mfg.; Air Trans.) 621.281-014.

    Science.gov (United States)

    Oregon State Dept. of Human Resources, Salem.

    This report is designed to provide information required to evaluate the Specific Aptitude Test Battery (SATB) for Airframe-and-Powerplant Mechanic from three points of view: (1) technical adequacy of the research, (2) fairness to minorities, and (3) usefulness of the battery to Employment Service staff and employers in selecting individuals for…

  4. Correlations Between in situ DCP Test and Laboratory Test Results

    OpenAIRE

    Plătică, Elena-Irina; Pohrib, Dana-Mădălina

    2014-01-01

    Geotechnical engineers are interested in investigating the actual behavior of the soil. Currently there are several methods available for assessing the properties of the soil. The variability of the geotechnical parameters resulting from these methods is neglected assuming that the mass of the soil is homogeneous and the variation of these parameters at various is rareli considered. Heterogeneity is a characteristic of the soil because their parameters vary from one point to another. To get a...

  5. Stand Alone Battery Thermal Management System

    Energy Technology Data Exchange (ETDEWEB)

    Brodie, Brad [Denso International America, Incorporated, Southfield, MI (United States)

    2015-09-30

    The objective of this project is research, development and demonstration of innovative thermal management concepts that reduce the cell or battery weight, complexity (component count) and/or cost by at least 20%. The project addresses two issues that are common problems with current state of the art lithium ion battery packs used in vehicles; low power at cold temperatures and reduced battery life when exposed to high temperatures. Typically, battery packs are “oversized” to satisfy the two issues mentioned above. The first phase of the project was spent making a battery pack simulation model using AMEsim software. The battery pack used as a benchmark was from the Fiat 500EV. FCA and NREL provided vehicle data and cell data that allowed an accurate model to be created that matched the electrical and thermal characteristics of the actual battery pack. The second phase involved using the battery model from the first phase and evaluate different thermal management concepts. In the end, a gas injection heat pump system was chosen as the dedicated thermal system to both heat and cool the battery pack. Based on the simulation model. The heat pump system could use 50% less energy to heat the battery pack in -20°C ambient conditions, and by keeping the battery cooler at hot climates, the battery pack size could be reduced by 5% and still meet the warranty requirements. During the final phase, the actual battery pack and heat pump system were installed in a test bench at DENSO to validate the simulation results. Also during this phase, the system was moved to NREL where testing was also done to validate the results. In conclusion, the heat pump system can improve “fuel economy” (for electric vehicle) by 12% average in cold climates. Also, the battery pack size, or capacity, could be reduced 5%, or if pack size is kept constant, the pack life could be increased by two years. Finally, the total battery pack and thermal system cost could be reduced 5% only if the

  6. Optimization of batteries for plug-in hybrid electric vehicles

    Science.gov (United States)

    English, Jeffrey Robb

    This thesis presents a method to quickly determine the optimal battery for an electric vehicle given a set of vehicle characteristics and desired performance metrics. The model is based on four independent design variables: cell count, cell capacity, state-of-charge window, and battery chemistry. Performance is measured in seven categories: cost, all-electric range, maximum speed, acceleration, battery lifetime, lifetime greenhouse gas emissions, and charging time. The performance of each battery is weighted according to a user-defined objective function to determine its overall fitness. The model is informed by a series of battery tests performed on scaled-down battery samples. Seven battery chemistries were tested for capacity at different discharge rates, maximum output power at different charge levels, and performance in a real-world automotive duty cycle. The results of these tests enable a prediction of the performance of the battery in an automobile. Testing was performed at both room temperature and low temperature to investigate the effects of battery temperature on operation. The testing highlighted differences in behavior between lithium, nickel, and lead based batteries. Battery performance decreased with temperature across all samples with the largest effect on nickel-based chemistries. Output power also decreased with lead acid batteries being the least affected by temperature. Lithium-ion batteries were found to be highly efficient (>95%) under a vehicular duty cycle; nickel and lead batteries have greater losses. Low temperatures hindered battery performance and resulted in accelerated failure in several samples. Lead acid, lead tin, and lithium nickel alloy batteries were unable to complete the low temperature testing regime without losing significant capacity and power capability. This is a concern for their applicability in electric vehicles intended for cold climates which have to maintain battery temperature during long periods of inactivity

  7. The Determination of Female 14-16 Years Old Basketball Players Biomotor and Physiological Features by Eurofit Test Battery

    Directory of Open Access Journals (Sweden)

    Mehmet Pense

    2010-12-01

    Full Text Available The aim of this study is to research the physical and biomotor features of female students who are in puberty and playbasketball. Also, it’s been aimed to test whether the Eurofit battery which is use to determine physiological and biomotorfeatures can be used in the elimination of talented basketball players. Anthropometric measurement (height, weight,percentage of body fat and physiological - biomotoric measurements (flamingo balance test, test of disk touching, sit andreach flexibility test, long jump while standing still, 30 sec sit-up test, bent arm pull-up test and 10x5m push up run wereperformed by Eurofit test battery. The research was applied in the province of Konya with 51 female students. 30 of themwere playing basketball (age: 14.93±0.86 and 21(age: 15.00±0.83 of them had no physiological activity at all. These appliedEurofit tests on basketball players allows them to get longer body length, stay more in balance, to have greater distance offlexibility, be further distance of standing long jump, to have a higher claw force, having more numbers on doing crunchesand it’s been mentioned that 10x5 the running test doing crunches are faster than usual and these differences are foundStatistical significant (p0,05. As a conclusion, it is determined that the physiological and biometricvalues of female basketball playing students are higher than the same aged students with no activity. On the other hand, it’sbeen also determined that because of the appropriate content of the test, Eurofit test battery can help to choose the talentsof the basketball.

  8. The Munich High Ability Test Battery (MHBT: A multidimensional, multimethod approach

    Directory of Open Access Journals (Sweden)

    CHRISTOPH PERLETH

    2008-06-01

    Full Text Available After a brief introduction the theoretical basis of the Munich High Ability Test-Battery (MHBT will be outlined in the first part of the article. The MHBT has been developed in the framework of the Munich longitudinal study of giftedness and talent. The MHBT includes not only cognitive predictors measuring several dimensions and types of giftedness concerning intellectual, creative or social abilities etc., but also giftedness-relevant non-cognitive personality and social moderators measuring interests, motivations, learning emotions, self-concepts or family and school climate, educational style, quality of instruction, etc. The MHBT-instruments (different scales and dimensions are described in greater detail.In the second part of the article, after dealing with the objectivity, the reliability, and the validity of the MHBT, the authors discuss the standardization procedure including the development of grade-based T-norms respectively as well as several talent-profiles, e.g. of gifted achievers vs. underachievers, intellectual, creative, social talents or linguistic, math, science talent profiles etc. Finally, examples of talent search for gifted programs and case studies on the basis of MHBT should illustrate multidimensional identification procedures.The MHBT fulfills the most relevant assessment tasks belonging to the gifted educational and counseling practice. The usefulness of the MHBT in the framework of giftedness research as well as of gifted program evaluation studies has also been proven in the last decade. Hence the MHBT offers many opportunities to assessing giftedness and talent.

  9. Driving Scenes test of the Neuropsychological Assessment Battery (NAB) and on-road driving performance in aging and very mild dementia

    OpenAIRE

    Brown, Laura B.; Stern, Robert A.; Cahn-Weiner, Deborah A.; Rogers, Brooke; Messer, Melissa A.; Lannon, Margaret C.; Maxwell, Charleen; Souza, Timothy; White, Travis; Ott, Brian R.

    2005-01-01

    The Driving Scenes test of the new Neuropsychological Assessment Battery (NAB; [Stern, R.A., & White, T. (2003a). Neuropsychological Assessment Battery. Lutz, FL: Psychological Assessment Resources, Inc.]) measures several aspects of visual attention thought to be important for driving ability. The current study examined the relationship between scores on the Driving Scenes test and on-road driving performance on a standardized driving test. Healthy participants performed significantly better...

  10. Design, Fabrication and Testing of Silicon-integrated Li-ion Secondary Micro Batteries with Side-by-Side Electrodes

    Science.gov (United States)

    Hoeppner, K.; Ferch, M.; Eisenreich, M.; Marquardt, K.; Hahn, R.; Mackowiak, P.; Mukhopadhyay, B.; Ngo, H.-D.; Gernhardt, R.; Toepper, M.; Lang, K.-D.

    2013-12-01

    This paper reports the design, fabrication, and testing of silicon-integrated lithium ion secondary micro batteries with a side-by-side electrode setup. Two cavities separated by a narrow silicon spacer served as a containment for the electrodes and were etched into -Si by wet chemical etching using aqueous KOH solution. The etched silicon battery containment was passivated by a stress-compensated layer of SiO2/Si3N4. Ti/Pt-current collectors were applied by E-beam evaporation and lift-off structuring. A volumetric dispenser served to fill the cavities with slurries of the active materials - lithium cobalt oxide (LiCoO2) as the anode and graphite as the cathode material. Encapsulation, electrolyte filling, and electrochemical characterisation of the finished cells took place in an Ar-filled glove box. The fabricated batteries have shown a rate capability of up to 5C and a linear capacity loss rate of <1 % per cycle over 30 full-cycles. Battery containments with different cavity and spacer widths have been fabricated.

  11. Functional Observational Battery Testing for Nervous System Effects of Drugs and Other Chemicals

    Science.gov (United States)

    Screening for behavioral toxicity, or neurotoxicity, has become standard practice in preclinical safety pharmacology and toxicology. Behavior represents the integrated sum of activities mediated by the nervous system. Current screening batteries, such as the functional observat...

  12. Design and Control of a Multi-Functional Energy Recovery Power Accumulator Battery Pack Testing System for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Bo Long

    2014-03-01

    Full Text Available In this paper, aiming at the energy loss and harmonic problems in the conventional power accumulator battery pack testing system (PABPTS, an improved multi-functional energy recovery PABPTS (ERPABPTS for electric vehicles (EVs was proposed. The improved system has the functions of harmonic detection, suppression, reactive compensation and energy recovery. The ERPABPTS, which contains a bi-directional buck-boost direct current (DC-DC converter and a bi-directional alternating current (AC-DC converter with an inductor-capacitor-inductor (LCL type filter interfacing to the AC-grid, is proposed. System configuration and operation principle of the combined system are discussed first, then, the reactive compensation and harmonic suppression controller under balanced grid-voltage condition are presented. Design of a fourth order band-pass Butterworth filter for current harmonic detection is put forward, and the reactive compensator design procedure considering the non-linear load is also illustrated. The proposed scheme is implemented in a 175-kW prototype in the laboratory. Simulation and experimental results show that the combined configuration can effectively realize energy recovery for high accuracy current test requirement, meanwhile, can effectively achieve reactive compensation and current harmonic suppression.

  13. Advanced Battery Diagnosis for Electric Vehicles

    OpenAIRE

    Lamichhane, Chudamani

    2008-01-01

    Summary Literatures on battery technologies and diagnosis of its parameters were studied. The innovative battery technologies from basic knowledge to world standard testing procedures were analysed and discussed in the report. The established battery test station and flowchart was followed during the battery test preparation and testing. In order to understand and verify the battery performance, the well established test procedures developed by USABC (United States Advanced Battery Consorti...

  14. Experimental test results of multi-channel test rig of T1 test section, 2

    International Nuclear Information System (INIS)

    Nonuniform power distribution test was performed with the multi-channel test rig of the fuel stack test section (T1) in order to contribute the licensing of the JAERI's High-Temperature Engineering Test Reactor (HTTR). In the test, helium gas was heated up to 750degC under asymmetric and slantwise power distributions realized by changing input electric powers of 12 simulated fuel rods respectively. Experimental results showed that the distribution of helium gas flow rate was influenced by the temperature distortion in the mock-up fuel stack. Calculated results with the numerical thermal analysis code indicated that the temperature distortion in the fuel stack was flattened by the thermal conduction in the graphite block. (author)

  15. EDIT: A New International Multicentre Programme to Develop and Evaluate Batteries of In Vitro Tests for Acute and Chronic Systemic Toxicity.

    Science.gov (United States)

    Ekwall, B; Clemedson, C; Ekwall, B; Ring, P; Romert, L

    1999-01-01

    The Multicenter Evaluation of In Vitro Cytotoxicity (MEIC) programme provided a battery of three basal cytotoxicity tests with a good (R2 = 0.77) prediction of human acute lethal blood concentrations. The predictive power of this battery would be considerably improved by the addition of new supplementary in vitro tests. The development of these new tests will be facilitated by a close coupling of test development to evaluation. The Cytotoxicology Laboratory, Uppsala (CTLU), is therefore inviting all interested in vitro toxicologists to take part in the Evaluation-guided Development of In Vitro Toxicity and Toxicokinetic Tests (EDIT). All EDIT activities (subprojects) will be designed on a case-by-case basis, but will follow a common pattern. The CTLU will use the accumulated MEIC/EDIT data, and its experience from the previous MEIC evaluation, to suggest priority areas, i.e. the need for certain in vitro toxicity data/tests as supplements to existing in vitro models/batteries on human systemic toxicity. Detailed research programmes corresponding to these areas will be published on the Internet. The CTLU will also try to raise funds for some projects and will coordinate multilaboratory studies. Interested laboratories developing or already using priority tests are encouraged to join the subprojects and to test specific sets of substances (usually sets of MEIC reference chemicals) in their new assays. The CTLU will provide adequate human reference data and will also evaluate results as single components of complex models, together with the laboratory conducting the test. At present, ten priority areas have been identified: a) repeat dose toxicity in vitro; b) urgent mechanistic information from in vitro studies of protein denaturation, morphology of cell injury, differential toxicity between various rapidly measured endpoints (10-60 minutes) and 24-hour cytotoxicity, toxicity to aerobic cells, and discrimination between rapid and slow cytotoxic mechanisms; c) in

  16. PBF-LOCA test series test LOC-11 test result report

    International Nuclear Information System (INIS)

    This report presents the results of Loss-of-Coolant (LOC) Test LOC-11, the first test of the Loss-of-Coolant Accident (LOCA) Test Series conducted by the Thermal Fuels Behavior Program of EG and G Idaho, Inc., in the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory. The primary objective of the test was to evaluate the behavior of pressurized water reactor (PWR) fuel under LOCA conditions similar to those postulated during a simulated double-ended cold leg break in a PWR. Test LOC-11 consisted of four, separately shrouded, fresh fuel rods of PWR design, with initial plenum pressure as a variable. Maximum cladding temperatures of up to 10700K (corresponding to high ductility α-phase Zircaloy) were sought during Test LOC-11. The fuel rods were exposed to a series of three blowdowns from different power and coolant conditions. The final blowdown resulted in the maximum measured cladding temperature of 10340K. Upon disassembly of the test train the rods were found to be uniformly covered with a dark grey oxide. Posttest results indicated slight cladding circumferential swelling of the pressurized rods and slight collapse of the relatively unpressurized rods. The results are compared with the posttest analyses to aid in understanding the coolant thermal-hydraulic behavior and fuel rod behavior

  17. Performance Testing of Yardney Li-Ion Cells and Batteries in Support of JPL's 2009 Mars Science Laboratory Mission

    Science.gov (United States)

    Smart, M.C.; Ratnakumar, B.V.; Whitcanack, L. D.; Dewell, E. A.; Jones, L. E.; Salvo, C. G.; Puglia, F. J.; Cohen, S.; Gitzendanner, R.

    2008-01-01

    In 2009, JPL is planning to launch an unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than three years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar lithium-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. Although comparable in many facets, such as being required to operate over a wide temperature range (-20 to 40 C), the MSL mission has more demanding performance requirements compared to the MER mission, including much longer mission duration (approx. 687 sols vs. 90 sols), higher power capability, and the need to withstand higher temperature excursions. In addition, due to the larger rover size, the MSL mission necessitates the use of a much larger battery to meet the energy, life, and power requirements. In order to determine the viability of meeting these requirements, a number of performance verification tests were performed on 10 Ah Yardney lithium-ion cells (MER design) under MSL-relevant conditions, including mission surface operation simulation testing. In addition, the performance of on-going ground life testing of 10 Ah MER cells and 8-cell batteries will be discussed in the context of capacity loss and impedance growth predictions.

  18. A LiFePO4 battery pack capacity estimation approach considering in-parallel cell safety in electric vehicles

    International Nuclear Information System (INIS)

    Highlights: • Find the influence of in-parallel battery cell variations on battery pack capacity. • Redefine the battery module capacity with considering ANY battery cell safety. • Discuss the safety end-of-charge voltage for an aged in-parallel battery module. • Build an algorithm for battery pack capacity estimation with the charge curve. • Bench tests are used to verify the validity of the proposed algorithm. - Abstract: In electric vehicles (EVs), several battery cells are connected in parallel to establish a battery module. The safety of the battery module is influenced by inconsistent battery cell performance which causes uneven currents flowing through internal in-parallel battery cells. A battery cell model is developed based on the Matlab–Simscape platform and validated by tests. The battery cell model is used to construct simulation models for analyzing the effect of battery cell inconsistency on the performance of an in-parallel battery module. Simulation results indicate that the state-of-charge (SOC) of a battery module cannot characterize the SOC of ALL the internal battery cells in the battery module. When the battery management system (BMS) controls the end-of-charge (EOC) time according to the SOC of a battery module, some internal battery cells are over-charged. To guarantee the safety of ALL battery cells through the whole battery life, a safety EOC voltage of the battery module should be set according to the number of battery cells in the battery module and the applied charge current. Simulations reveal that the SOC of the “normal battery module” is related to its charge voltage when aged battery module is charged to the EOC voltage. Then, a function describing their relationship is established. Both the capacity and the charge voltage shift are estimated by comparing the measured voltage-to-capacity curve with the standard one provided by the manufactory. A battery pack capacity estimation method is proposed according to the SOC

  19. Effects of state of charge on the degradation of LiFePO4/graphite batteries during accelerated storage test

    International Nuclear Information System (INIS)

    Highlights: • Degradation of LiFePO4/graphite batteries under different state of charge at 55 °C is investigate. • Side reactions caused by self-discharge are the main reason for performance fade during storage. • The detailed degradation mechanism is proven by post-mortem analysis. • Increased electrode resistance in LiFePO4 cathode suggests that side reactions also happen at positive electrode. - Abstract: In this paper, the degradation of LiFePO4/graphite batteries during 10 months of storage under different temperatures and states of charge (SOCs) is studied. The effects of SOC during storage process are systematically investigated using electrochemical methods and post-mortem analysis. The results show that at elevated temperature of 55 °C, higher stored SOC results in more significant increase in bulk resistance (Rb) and charge-transfer resistance (Rct) of full battery, whereas the rate-discharge capability of stored battery is unchanged. The side reactions at the electrode/electrolyte interface caused by self-discharge are the main reasons for the performance fading during storage. For LiFePO4 cathode, long-time storage does not influence the framework structure under various SOCs. The existence of little irreversible capacity loss and impedance increase indicates that side reactions also occur at the positive electrode. For graphite anode, only a little capacity loss is found upon storage. There is a significant increase in impedance and a small amount of Fe deposition on graphite anode after storage at 100% SOC and 55 °C. The lithium ion loss arises from side reactions taking place at the graphite anode, which is responsible for the capacity degradation of battery during the storage process. XPS analysis confirms that a deposit layer composed of Li2CO3 and LiF is formed on the surface of anode

  20. Seismic fragility testing of naturally-aged, safety-related, class 1E battery cells

    International Nuclear Information System (INIS)

    The concern over seismic susceptibility of naturally-aged lead-acid batteries used for safety-related emergency power in nuclear power stations was brought about by battery problems that periodically had been reported in Licensee Event Reports (LERs). The Turkey Point Station had reported cracked and buckled plates in several cells in October 1974 (LER 75-5). The Fitzpatrick Station had reported cracked battery cell cases in October 1977 (LER 77-55) and again in September 1979 (LER 79-59). The Browns Ferry Station had reported a cracked cell leaking a small quantity of electrolyte in July 1981 (LER 81-42). The Indian Point Station had reported cracked and leaking cells in both February (LER 82-7) and April 1982 (LER 82-16); both of these LERs indicated the cracked cells were due to expansion (i.e., growth) of the positive plates

  1. Results of a technical analysis of the Hubble Space Telescope nickel-cadmium and nickel-hydrogen batteries

    Science.gov (United States)

    Manzo, Michelle A.

    1991-01-01

    The Hubble Space Telescope (HST) Program Office requested the expertise of the NASA Aerospace Flight Battery Systems Steering Committee (NAFBSSC) in the conduct of an independent assessment of the HST's battery system to assist in their decision of whether to fly nickel-cadmium or nickel-hydrogen batteries on the telescope. In response, a subcommittee to the NAFBSSC was organized with membership comprised of experts with background in the nickel-cadmium/nickel-hydrogen secondary battery/power systems areas. The work and recommendations of that subcommittee are presented.

  2. Executive functioning in three groups of pupils in D-KEFS: Selected issues in adapting the test battery for Slovakia

    Directory of Open Access Journals (Sweden)

    Ferjenčík Ján

    2015-06-01

    Full Text Available The paper reports on the adaptation of a D-KEFS test battery for Slovakia. Drawing on concrete examples, it describes and illustrates the key issues relating to the transfer of test items from one socio-cultural environment to another. The standardisation sample of the population of Slovak pupils in the fourth year of primary school included 250 children with an average age of 9.7 years. The two comparative samples of the same age range were analysed at the same time. They included pupils from classes for gifted children (n = 55 and Roma children from socially disadvantaging environments (n = 50.

  3. Effects of Testing Conditions on Conceptual Survey Results

    Science.gov (United States)

    Ding, Lin; Reay, Neville W.; Lee, Albert; Bao, Lei

    2008-01-01

    Pre-testing and post-testing is a commonly used method in Physics Education Research to assess student learning gains. It is well recognized in the community that timings and incentives in delivering conceptual tests can impact test results. However, it is difficult to control these variables across different studies. As a common practice, a…

  4. Button batteries

    Science.gov (United States)

    Swallowing batteries ... These devices use button batteries: Calculators Cameras Hearing aids Penlights Watches ... If a person puts the battery up their nose and breathes it further in, ... problems Cough Pneumonia (if the battery goes unnoticed) ...

  5. [Return for HIV test results after voluntary screening in Cameroon].

    Science.gov (United States)

    2016-01-01

    The results of this study indicate that individuals who voluntarily undergo an HIV test in PVTCCs of the Douala district hospitals in Cameroon perceived real advantages and very few disadvantages and barriers to know their HIV status. Particular attention should be given to organizational factors that may be responsible for failure to return for HIV test results and post-test counselling.. PMID:27531439

  6. Comparison study on the battery models used for the energy management of batteries in electric vehicles

    International Nuclear Information System (INIS)

    Highlights: ► The seven representative battery models are summarized. ► The model equations are built and the model parameters are identified with an online method. ► An evaluation is performed on the battery models by an experiment approach. ► The equivalent circuit model with two RC networks has an optimal performance. - Abstract: Battery model plays an important role in the simulation of electric vehicles (EVs) and states estimation of the batteries in the development of the model-based battery management system. To build a battery model with enough precision and suitable complexity, firstly this paper summarizes the seven representative battery models, which belong to the simplified electrochemical models or the equivalent circuit models. Then the model equations are built and the model parameters are identified with an online parameter identification method. The battery test bench is built and the experiment schedule is designed. Finally an evaluation is performed on the seven battery models by an experiment approach from the aspects of the estimation accuracy of the terminal voltages. To evaluate the effect of the number of RC networks on the model’s precision, the battery general equivalent circuit models (GECMs) with different RC networks are also discussed further. The results indicate the equivalent circuit model with two RC networks, the DP model, has an optimal performance.

  7. Making Sense of Your Pap and HPV Test Results

    Science.gov (United States)

    ... Sexually Transmitted Diseases (STDs) Making Sense of Your Pap & HPV Test Results Language: English Español (Spanish) Recommend ... abnormal cells and lead to cervical cancer. The Pap and HPV tests can find early problems that ...

  8. Test results of the DOE/Sandia 17 meter VAWT

    Science.gov (United States)

    Nellums, R. O.; Worstell, M. H.

    1979-01-01

    A review is given of the test program of a 17 meter Vertical Axis Wind Turbine VAWT. Performance test results are discussed including difficulties encountered during the VAWT operation along with ways of solving these problems.

  9. Design, Fabrication, and Testing of Silicon-integrated Li-ion Secondary Micro Batteries with Interdigital Electrodes

    Science.gov (United States)

    Hoeppner, K.; Ferch, M.; Froebe, A.; Gernhardt, R.; Hahn, R.; Mackowiak, P.; Mukhopadhyay, B.; Roder, S.; Saalhofen, I.; Lang, K.-D.

    2015-12-01

    This paper reports the design, fabrication, and testing of silicon-integrated lithium ion secondary micro batteries with a side-by-side electrode setup. Cavities separated by narrow silicon spacers served as containments for two interdigitally arranged electrodes and were etched into -Si by wet chemical etching. The etched silicon battery containments were passivated by a layer of SiOx/SixNy. Al current collectors were applied by sputtering and back etching. A volumetric micro dispenser served to fill the cavities with slurries of the active materials - lithium cobalt manganese oxide (Liy(Ni1/2Co1/5Mn3/10)O2) as the cathode and lithium titanate (Li4Ti5O12) as the anode material. Filling with electrolyte, encapsulation, and electrochemical characterization of the finished cells took place in an Ar-filled glove box. The fabricated batteries with IDE show considerably lower impedances than cells with single side by side electrodes and are capable of constant current loads up to 10 C. A linear capacity loss rate of <0.1% per cycle was observed over 30 full cycles at 0.2C.

  10. Effects of testing conditions on conceptual survey results

    Directory of Open Access Journals (Sweden)

    Lin Ding

    2008-06-01

    Full Text Available Pre-testing and post-testing is a commonly used method in Physics Education Research to assess student learning gains. It is well recognized in the community that timings and incentives in delivering conceptual tests can impact test results. However, it is difficult to control these variables across different studies. As a common practice, a pre-test is often administered either at or near the beginning of a course, while a post-test can be given either at or near the end of a course. Also, in conducting such tests there often is no norm as to whether incentives should be offered to students. Because these variations can significantly affect test results, it is important to study and document their impact. We analyzed five years of data that were collected at The Ohio State University from over 2100 students, who took both the pre-test and post-test of the Conceptual Survey of Electricity and Magnetism under various timings and incentives. We observed that the actual time frame for giving a test has a marked effect on the test results and that incentive granting also has a significant influence on test outcomes. These results suggest that one should carefully monitor and document the conditions under which tests are administered.

  11. Stability, reliability and cross-mode correlations of tests in a recommended 8-minute performance assessment battery

    Science.gov (United States)

    Wilkes, R. L.; Kennedy, R. S.; Dunlap, W. P.; Lane, N. E.

    1986-01-01

    A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests.

  12. Assessment of cognition using the Rao's Brief Repeatable Battery of Neuropsychological Tests on a group of Brazilian patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Joseph Bruno Bidin Brooks

    2011-12-01

    Full Text Available To assess the cognition of patients with multiple sclerosis (MS using the Rao's Brief Repeatable Battery of Neuropsychological Tests (BRB-N. METHOD: BRB-N was translated and adapted for control subjects. Subsequently, it was applied to a group of patients with relapsing-remitting (RR MS. RESULTS: The assessment on the healthy controls (n=47 showed that the correlation between tests on the same cognitive domain was high and that there was a five-factor solution that explained 90% of the total variance. Except for the Word List Generation subset of tests, the performance of patients with RRMS (n=39 was worse than that of the healthy controls. CONCLUSION: BRB-N is a relatively simple method to assess cognition of patients with MS in the daily clinic. It does not take long to apply and does not require special skills or equipment.

  13. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  14. Reliability Through Life of Internal Protection Devices in Small-Cell ABSL Batteries

    Science.gov (United States)

    Neubauer, Jeremy; Ng, Ka Lok; Bennetti, Andrea; Pearson, Chris; Rao, gopal

    2007-01-01

    This viewgraph presentation reviews a reliability analysis of small cell protection batteries. The contents include: 1) The s-p Topology; 2) Cell Level Protection Devices; 3) Battery Level Fault Protection; 4) Large Cell Comparison; and 5) Battery Level Testing and Results.

  15. Prismatic sealed nickel-cadmium batteries utilizing fiber structured electrodes. II - Applications as a maintenance free aircraft battery

    Science.gov (United States)

    Anderman, Menahem; Benczur-Urmossy, Gabor; Haschka, Friedrich

    Test data on prismatic sealed Ni-Cd batteries utilizing fiber structured electrodes (sealed FNC) is discussed. It is shown that, under a voltage limited charging scheme, the charge acceptance of the sealed FNC battery is far superior to that of the standard vented aircraft Ni-Cd batteries. This results in the sealed FNC battery maintaining its capacity over several thousand cycles without any need for electrical conditioning or water topping. APU start data demonstrate superior power capabilities over existing technologies. Performance at low temperature is presented. Abuse test results reveal a safe fail mechanism even under severe electrical abuse.

  16. The Facial Expressive Action Stimulus Test. A test battery for the assessment of face memory, face and object perception, configuration processing, and facial expression recognition

    OpenAIRE

    DE GELDER, Beatrice; Huis In ‘T Veld, Elisabeth M. J.; Van den Stock, Jan

    2015-01-01

    There are many ways to assess face perception skills. In this study, we describe a novel task battery FEAST (Facial Expressive Action Stimulus Test) developed to test recognition of identity and expressions of human faces as well as stimulus control categories. The FEAST consists of a neutral and emotional face memory task, a face and shoe identity matching task, a face and house part-to-whole matching task, and a human and animal facial expression matching task. The identity and part-to-whol...

  17. Assembler (elec. equip.) 826.884, Assembler, Electrical (elec. equip.) 826.884--Technical Report on Development of USTES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  18. Coil Assembler 6-94.515; Unit Assembler 8-93.41; Unit Assembler 8-94.51 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  19. Clicking-Machine Operator (boot & show; leather prod.) 6-62.055--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  20. Die-Casting-Machine Operator (nonfer. metal alloys & prod.) II 6-82.916--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  1. Screw-Machine Set-Up Operator, Jobbing (mach. shop) 604.380-028--Technical Report on Development of USTES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  2. Injection-Molding-Machine Tender (fabric-plastics prod.) 556.885--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  3. Twister-Tender (asbestos prod; glass mfg.; synthetic fibers; textile) 681.885--Technical Report on Development of USTES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  4. Asparagus Sorter (agric.; can. & preserv.; whole tr.) 529.687 (8-04.10)--Technical Report on Development of USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  5. EDD-7 Electric Charge Point Meter test results

    Science.gov (United States)

    Mersman, C. R.

    1993-09-01

    The results of tests evaluating the electric switching portion of the EDD-7 Electric Charge Point Meter (ECPM) are presented. The ECPM is a modified parking meter that allows the purchase of 120 or 240 volt electric power. The ECPM is designed to make electricity available at any vehicle parking location. The test results indicate that the ECPM operated without failure through a series of over current and ground fault tests at three different test temperatures. The magnitude of current required to trip the over current protection circuitry varied with temperature while the performance of the ground fault interruption circuitry did not change significantly with the test temperature.

  6. Comparison between tensile, stiffness and fatigue life tests results

    OpenAIRE

    Silva, Hugo Manuel Ribeiro Dias da; Pais, Jorge C.; Pereira, Paulo A. A.

    2003-01-01

    A laboratory mechanical test is being implemented in the University of Minho to evaluate the asphalt-aggregate interaction. This test measures the tensile properties of the bituminous mixture in the interface between the asphalt and the aggregates. By using the tensile test it is intended to observe how the asphalt-aggregate interaction influences the mechanical properties of the bituminous mixtures, namely, stiffness modulus and fatigue life. The tensile test results must have a good correla...

  7. New Technology for USB Battery Charging and Testing Method%最新USB充电技术与测试

    Institute of Scientific and Technical Information of China (English)

    魏明

    2011-01-01

    The USB2.0 spec does not take into account the applications that portable devices charging their batteries on an USB port,but such applications are becoming more and more popular.This paper describes the main content of the battery charging specification version 1.2 which is latest issued by USB-IF.Then,it gives a brief introduction of the related test specifications and introduces the key items and difficult contents during the tests based on the test experience.%USB2.0规范并没有考虑到使用USB接口为便携式设备的电池进行充电的需求,而这样的应用需求却越来越多。本文首先介绍USB-IF最新颁布的电池充电规范v1.2版本的主要内容;然后对其相关测试规范做简单介绍;最后结合测试经验,对测试中的重点项目和难点内容进行说明。

  8. Validação da bateria "Beck" de testes de habilidades para atletas brasileiros de "rugby" em cadeira de rodas Validation of beck battery of skills tests to Brazilian players of wheelchair rugby

    Directory of Open Access Journals (Sweden)

    José Irineu Gorla

    2011-09-01

    passing, blocking, speed and long distance passing to wheelchair rugby athletes was developed in the U.S.A. by Yilla & Sherrill (1998.The aim of this study was to examine the criteria of scientific authenticity of the battery to the Brazilian athletes population. The results of two assessments with the battery (test and retest with 11 athletes (mean age 27.59 ± 5.37 years, length of lesion 8.19 ± 3.83 years, were recorded by three assessors , which allowed the analysis of objectivity, reliability and internal consistency. We used ANOVA for analysis of objectivity and linear correlation and t test for analysis of reliability and consistency. No differences were found between results from different raters (p values ranging from 0.45 to 1.00 and the values of intraclass correlation coefficient found (range r 0.78 to 0.99 p < 0.00 indicate that the battery is consistent and reliable. The results of this study indicate that the criteria of scientific authenticity to the battery are satisfied and battery can be considered a valid tool for motricity evaluation of wheelchair rugby brazilian players.

  9. Assessing Specific Cognitive Deficits Associated with Dementia in Older Adults with Down Syndrome: Use and Validity of the Arizona Cognitive Test Battery (ACTB)

    Science.gov (United States)

    Sinai, Amanda; Hassiotis, Angela; Rantell, Khadija; Strydom, Andre

    2016-01-01

    Background Down syndrome is associated with specific cognitive deficits. Alongside this, older adults with Down syndrome are a high risk group for dementia. The Arizona Cognitive Test Battery (ACTB), a cognitive assessment battery specifically developed for use with individuals with Down syndrome, has been proposed for use as outcome measures for clinical trials in this population. It has not been validated in older adults with Down syndrome. This study aims to assess the use and validity of the ACTB in older adults with Down syndrome. Methods Participants with Down syndrome aged 45 and over were assessed using the ACTB, standard tabletop tests and informant ratings. Results Assessment outcomes of 49 participants were analysed. Of these, 19 (39%) had a diagnosis of dementia or possible dementia. Most participants were able to attempt most of the tasks, although some tasks had high floor effects (including CANTAB Intra-Extra Dimensional shift stages completed and Modified Dots Task). Of the ACTB tasks, statistically significant differences were observed between the dementia and no dementia groups on CANTAB Simple Reaction Time median latency, NEPSY Visuomotor Precision—Car and Motorbike and CANTAB Paired Associates Learning stages completed. No significant differences were observed for CANTAB Intra-Extra Dimensional Shift, Modified Dots Task, Finger Sequencing, NEPSY Visuomotor precision—Train and Car and CANTAB Paired Associates Learning first trial memory score. Several of the tasks in the ACTB can be used in older adults with Down syndrome and have mild to moderate concurrent validity when compared to tabletop tests and informant ratings, although this varies on a test by test basis. Conclusions Overall, scores for a number of tests in the ACTB were similar when comparing dementia and no dementia groups of older adults with Down syndrome, suggesting that it would not be an appropriate outcome measure of cognitive function for clinical trials of dementia

  10. Effect of incubation conditions on anaerobic susceptibility testing results.

    OpenAIRE

    Murray, P R; Niles, A C

    1982-01-01

    We determined the effect of performing antimicrobial susceptibility tests in five different anaerobic incubation systems: GasPak jar, large GasPak jar, evacuated-gassed anaerobic jar, anaerobic chamber, and Bio-Bag. Growth of the anaerobes was equivalent in all five incubation systems. The results of testing 38 anaerobes against 11 antimicrobial agents were comparable for the anaerobic jars and anaerobic chamber. However, discordant results were observed for metronidazole and cefamandole test...

  11. Lithium-Ion Battery Cell Cycling and Usage Analysis in a Heavy-Duty Truck Field Study

    OpenAIRE

    Pontus Svens; Mårten Behm; Göran Lindbergh

    2015-01-01

    This paper presents results from a field test performed on commercial power-optimized lithium-ion battery cells cycled on three heavy-duty trucks. The goal with this study was to age battery cells in a hybrid electric vehicle (HEV) environment and find suitable methods for identifying cell ageing. The battery cells were cycled on in-house developed equipment intended for testing on conventional vehicles by emulating an HEV environment. A hybrid strategy that allows battery usage to vary withi...

  12. Lithium-Ion Battery Cell Cycling and Usage Analysis in a Heavy-Duty Truck Field Study

    OpenAIRE

    Pontus Svens; Mårten Behm; Göran Lindbergh

    2015-01-01

    This paper presents results from a field test performed on commercial power-optimized lithium-ion battery cells cycled on three heavy-duty trucks. The goal with this study was to age battery cells in a hybrid electric vehicle (HEV) environment and find suitable methods for identifying cell ageing. The battery cells were cycled on in-house developed equipment intended for testing on conventional vehicles by emulating an HEV environment. A hybrid strategy that allows battery usage to vary with...

  13. Advanced Battery Manufacturing (VA)

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, Jeremy

    2012-09-30

    LiFeBATT has concentrated its recent testing and evaluation on the safety of its batteries. There appears to be a good margin of safety with respect to overheating of the cells and the cases being utilized for the batteries are specifically designed to dissipate any heat built up during charging. This aspect of LiFeBATT’s products will be even more fully investigated, and assuming ongoing positive results, it will become a major component of marketing efforts for the batteries. LiFeBATT has continued to receive prismatic 20 Amp hour cells from Taiwan. Further testing continues to indicate significant advantages over the previously available 15 Ah cells. Battery packs are being assembled with battery management systems in the Danville facility. Comprehensive tests are underway at Sandia National Laboratory to provide further documentation of the advantages of these 20 Ah cells. The company is pursuing its work with Hybrid Vehicles of Danville to critically evaluate the 20 Ah cells in a hybrid, armored vehicle being developed for military and security applications. Results have been even more encouraging than they were initially. LiFeBATT is expanding its work with several OEM customers to build a worldwide distribution network. These customers include a major automotive consulting group in the U.K., an Australian maker of luxury off-road campers, and a number of makers of E-bikes and scooters. LiFeBATT continues to explore the possibility of working with nations that are woefully short of infrastructure. Negotiations are underway with Siemens to jointly develop a system for using photovoltaic generation and battery storage to supply electricity to communities that are not currently served adequately. The IDA has continued to monitor the progress of LiFeBATT’s work to ensure that all funds are being expended wisely and that matching funds will be generated as promised. The company has also remained current on all obligations for repayment of an IDA loan and lease

  14. Test results judgment method based on BIT faults

    Institute of Scientific and Technical Information of China (English)

    Wang Gang; Qiu Jing; Liu Guanjun; Lyu Kehong

    2015-01-01

    Built-in-test (BIT) is responsible for equipment fault detection, so the test data correct-ness directly influences diagnosis results. Equipment suffers all kinds of environment stresses, such as temperature, vibration, and electromagnetic stress. As embedded testing facility, BIT also suffers from these stresses and the interferences/faults are caused, so that the test course is influenced, resulting in incredible results. Therefore it is necessary to monitor test data and judge test failures. Stress monitor and BIT self-diagnosis would redound to BIT reliability, but the existing anti-jamming researches are mainly safeguard design and signal process. This paper focuses on test results monitor and BIT equipment (BITE) failure judge, and a series of improved approaches is proposed. Firstly the stress influences on components are illustrated and the effects on the diagnosis results are summarized. Secondly a composite BIT program is proposed with information integra-tion, and a stress monitor program is given. Thirdly, based on the detailed analysis of system faults and forms of BIT results, the test sequence control method is proposed. It assists BITE failure judge and reduces error probability. Finally the validation cases prove that these approaches enhance credibility.

  15. Results of recent KROTOS FCI tests. Alumina vs. corium melts

    Energy Technology Data Exchange (ETDEWEB)

    Huhtiniemi, I.; Magallon, D.; Hohmann, H. [Commission of the European Communities, Ispra (Italy). Joint Research Center

    1998-01-01

    Recent results from KROTOS fuel-coolant interaction experiments are discussed. Five tests with alumina were performed under highly subcooled conditions, all of these tests resulted in spontaneous steam explosions. Additionally, four tests were performed at low subcooling to confirm, on one hand, the suppression of spontaneous steam explosions under such conditions and, on the other hand, that such a system is still triggerable using an external initiator. The other test parameters in these alumina tests included the melt superheat and the initial pressure. All the tests in the investigated superheat range (150 K - 750 K) produced a steam explosion and no evidence of the explosion suppression by the elevated initial pressure (in the limited range of 0.1 - 0.375 MPa) was observed in the alumina tests. The corium test series include a test with 3 kg of melt under both subcooled and near saturated conditions at ambient pressure. Two additional tests were performed with subcooled water; one test was performed at an elevated pressure of 0.2 MPa with 2.4 kg of melt and another test with 5.1 kg of melt at ambient pressure. None of these tests with corium produced a propagating energetic steam explosion. However, propagating low energy (about twice the energy of the trigger pulse) events were observed. All corium tests produced significantly higher water level swells during the mixing phase than the corresponding alumina tests. Present experimental evidence suggests that the water depletion in the mixing zone suppresses energetic steam explosions with corium melts at ambient pressure and in the present pour geometry. Processes that could produce such a difference in void generation are discussed. (author)

  16. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  17. Micro-hybrid electric vehicle application of valve-regulated lead-acid batteries in absorbent glass mat technology: Testing a partial-state-of-charge operation strategy

    Energy Technology Data Exchange (ETDEWEB)

    Schaeck, S.; Stoermer, A.O.; Hockgeiger, E. [BMW Group, Powertrain Development, Energy Storage, Hufelandstrasse 4, 80788 Muenchen (Germany)

    2009-05-01

    The BMW Group has launched two micro-hybrid functions in high volume models in order to contribute to reduction of fuel consumption in modern passenger cars. Both the brake energy regeneration (BER) and the auto-start-stop function (ASSF) are based on the conventional 14 V vehicle electrical system and current series components with only little modifications. An intelligent control algorithm of the alternator enables recuperative charging in braking and coasting phases, known as BER. By switching off the internal combustion engine at a vehicle standstill the idling fuel consumption is effectively reduced by ASSF. By reason of economy and package a lead-acid battery is used as electrochemical energy storage device. The BMW Group assembles valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology in the micro-hybrid electrical power system since special challenges arise for the batteries. By field data analysis a lower average state-of-charge (SOC) due to partial state-of-charge (PSOC) operation and a higher cycling rate due to BER and ASSF are confirmed in this article. Similar to a design of experiment (DOE) like method we present a long-term lab investigation. Two types of 90 Ah VRLA AGM batteries are operated with a test bench profile that simulates the micro-hybrid vehicle electrical system under varying conditions. The main attention of this lab testing is focused on capacity loss and charge acceptance over cycle life. These effects are put into context with periodically refresh charging the batteries in order to prevent accelerated battery aging due to hard sulfation. We demonstrate the positive effect of refresh chargings concerning preservation of battery charge acceptance. Furthermore, we observe moderate capacity loss over 90 full cycles both at 25 C and at 3 C battery temperature. (author)

  18. Micro-hybrid electric vehicle application of valve-regulated lead-acid batteries in absorbent glass mat technology: Testing a partial-state-of-charge operation strategy

    Science.gov (United States)

    Schaeck, S.; Stoermer, A. O.; Hockgeiger, E.

    The BMW Group has launched two micro-hybrid functions in high volume models in order to contribute to reduction of fuel consumption in modern passenger cars. Both the brake energy regeneration (BER) and the auto-start-stop function (ASSF) are based on the conventional 14 V vehicle electrical system and current series components with only little modifications. An intelligent control algorithm of the alternator enables recuperative charging in braking and coasting phases, known as BER. By switching off the internal combustion engine at a vehicle standstill the idling fuel consumption is effectively reduced by ASSF. By reason of economy and package a lead-acid battery is used as electrochemical energy storage device. The BMW Group assembles valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology in the micro-hybrid electrical power system since special challenges arise for the batteries. By field data analysis a lower average state-of-charge (SOC) due to partial state-of-charge (PSOC) operation and a higher cycling rate due to BER and ASSF are confirmed in this article. Similar to a design of experiment (DOE) like method we present a long-term lab investigation. Two types of 90 Ah VRLA AGM batteries are operated with a test bench profile that simulates the micro-hybrid vehicle electrical system under varying conditions. The main attention of this lab testing is focused on capacity loss and charge acceptance over cycle life. These effects are put into context with periodically refresh charging the batteries in order to prevent accelerated battery aging due to hard sulfation. We demonstrate the positive effect of refresh chargings concerning preservation of battery charge acceptance. Furthermore, we observe moderate capacity loss over 90 full cycles both at 25 °C and at 3 °C battery temperature.

  19. Distinguishing between autism spectrum disorder and attention deficit hyperactivity disorder by using behavioral checklists, cognitive assessments, and neuropsychological test battery.

    Science.gov (United States)

    Matsuura, Naomi; Ishitobi, Makoto; Arai, Sumiyoshi; Kawamura, Kaori; Asano, Mizuki; Inohara, Keisuke; Narimoto, Tadamasa; Wada, Yuji; Hiratani, Michio; Kosaka, Hirotaka

    2014-12-01

    Children with attention deficit hyperactivity disorder (ADHD) and autism spectrum disorder (ASD) share many common symptoms, including attention deficit, behavioral problems, and difficulties with social skills. The aim of this study was to distinguish between ASD and ADHD by identifying the characteristic features of both the disorders, by using multidimensional assessments, including screening behavioral checklists, cognitive assessments, and comprehensive neurological battery. After screening for comorbid disorders, we carefully selected age-, sex-, IQ-, and socio-economic status-matched children with typical development (TD). In the Wechsler Intelligence Scale for children, a lower score was observed for the ASD group than for the TD group in Picture concept, which is a subscale of perceptual reasoning. A lower score was shown by the ADHD group than by the TD group in the spatial working memory test in the Cambridge Neuropsychological Test Automated Battery (CANTAB(®)). Although ASD and ADHD have many similar symptoms, they can be differentiated by focusing on the behavioral and cognitive characteristics of executive function. PMID:25440561

  20. Recognition disorders for famous faces and voices: a review of the literature and normative data of a new test battery.

    Science.gov (United States)

    Quaranta, Davide; Piccininni, Chiara; Carlesimo, Giovanni Augusto; Luzzi, Simona; Marra, Camillo; Papagno, Costanza; Trojano, Luigi; Gainotti, Guido

    2016-03-01

    Several anatomo-clinical investigations have shown that familiar face recognition disorders not due to high level perceptual defects are often observed in patients with lesions of the right anterior temporal lobe (ATL). The meaning of these findings is, however, controversial, because some authors claim that these patients show pure instances of modality-specific 'associative prosopagnosia', whereas other authors maintain that in these patients voice recognition is also impaired and that these patients have a 'multimodal person recognition disorder'. To solve the problem of the nature of famous faces recognition disorders in patients affected by right ATL lesions, it is therefore very important to verify with formal tests if these patients are or are not able to recognize others by voice, but a direct comparison between the two modalities is hindered by the fact that voice recognition is more difficult than face recognition. To circumvent this difficulty, we constructed a test battery in which subjects were requested to recognize the same persons (well-known at the national level) through their faces and voices, evaluating familiarity and identification processes. The present paper describes the 'Famous People Recognition Battery' and reports the normative data necessary to clarify the nature of person recognition disorders observed in patients affected by right ATL lesions. PMID:26700802

  1. Repository seal material development physical testing program results

    International Nuclear Information System (INIS)

    This document presents results of laboratory tests conducted in fiscal years 1980 and 1981 under contract CPFF 700 by Woodward-Clyde Consultants. The purpose of the physical testing was to develop preliminary repository sealing material data for materials identified in previous preconceptual studies for sealing of a repository in basalt. Materials tests included expansive cements, mortars, cement grouts, and clay-sand mixtures. Tests were performed to develop crushing strengths, permeability, and segregation characteristics to yield information useful in assessing potential physical stability of candidate plug materials under simulated host rock environments, and also develop host rock plug interface permeability data. Many of the basalt sand-clay specimens tested were required to be fully saturated prior to measuring some key laboratory values. Saturation was not obtained within the available test time and a complete set of results was not obtained

  2. New results from pulse tests in the CABRI reactor

    International Nuclear Information System (INIS)

    At the 21st and 22nd WRSM (1,2), the motivation and objectives of the French program on the behaviour of high burnup PWR fuel under RIA conditions in the CABRI test reactor has been presented. The major results of the three first tests of the test matrix were presented and in particular REP-Na1, which failed at an unexpected low level of fuel enthalpy, was exposed to the community of nuclear safety research. At this time, no final understanding was reached for the origin of the failure. This objective is reached now. Two further tests, REP-Na4 and 5, have been performed in 1995, they demonstrated a satisfactory and safe behaviour by resisting to the early phase of severe loading during the RIA pulse test. Further examination work and analytical testing is in progress and the next tests with MOX fuel are being prepared

  3. New results from pulse tests in the CABRI reactor

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, F.; Papin, J.; Haessler, M. [Institut de Proterction et de Surete Nucleaire, Saint Paul Lez Durance (France)] [and others

    1996-03-01

    At the 21st and 22nd WRSM (1,2), the motivation and objectives of the French program on the behaviour of high burnup PWR fuel under RIA conditions in the CABRI test reactor has been presented. The major results of the three first tests of the test matrix were presented and in particular REP-Na1, which failed at an unexpected low level of fuel enthalpy, was exposed to the community of nuclear safety research. At this time, no final understanding was reached for the origin of the failure. This objective is reached now. Two further tests, REP-Na4 and 5, have been performed in 1995, they demonstrated a satisfactory and safe behaviour by resisting to the early phase of severe loading during the RIA pulse test. Further examination work and analytical testing is in progress and the next tests with MOX fuel are being prepared.

  4. Colorectal Tumour Microsatellite Instability Test Results: Perspectives from Patients

    Directory of Open Access Journals (Sweden)

    Lindor Noralane M

    2004-05-01

    Full Text Available Abstract Purpose To determine which individuals with colorectal cancer (CRC were interested in knowing the results of their tumour microsatellite instability (MSI and immunohistochemistry (IHC testing. We were also interested in the patients' reasons for choosing to learn their results and in the impact of those results on overall self-assessed quality of life. Patients and Methods CRCs from 414 individuals were assayed for MSI and IHC for DNA mismatch repair gene products (MLH1, MSH2, MSH6. Individuals were invited to learn their MSI/IHC results. They randomly received either brief or extended educational materials about the testing and a pretest survey to learn reasons for their interest and to assess their pretest quality of life. Results Of the 414 individuals, 307 (74% chose to learn their results. There was no significant difference in interest in knowing test results according to gender, age, educational level, or family history of colon cancer. The level of detail in the information piece received by the patients did not influence their desire to know their test results. Self-assessed quality of life was not altered by receiving results and was not correlated with the test outcome. Conclusions Individuals with colorectal cancer had a high level of interest in learning their individual MSI/IHC test results and did not seem deterred by the inherent complexity or ambiguity of this information. Regardless of test outcome, results did not significantly affect self-assessed quality of life. Further studies are needed to assess comprehension of results and behavioural changes resulting from the learning of MSI/IHC results.

  5. 78 FR 15753 - Maintenance, Testing, and Replacement of Vented Lead-Acid Storage Batteries for Nuclear Power Plants

    Science.gov (United States)

    2013-03-12

    ... which a battery can be returned to service and be able to meet its capacity and capability requirements, and (4) consistency with standard technical specifications regarding battery monitoring criteria....

  6. Battery Test Manual For 12 Volt Start/Stop Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Belt, Jeffrey R. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    This manual was prepared by and for the United Stated Advanced Battery Consortium (USABC) Electrochemical Energy Storage Team. It is based on the targets established for 12 Volt Start/Stop energy storage development and is similar (with some important changes) to an earlier manual for the former FreedomCAR program. The specific procedures were developed primarily to characterize the performance of energy storage devices relative to the USABC requirements. However, it is anticipated that these procedures will have some utility for characterizing 12 Volt Start/Stop hybrid energy storage device behavior in general.

  7. Analyzing and Reporting School District Standardized Test Results.

    Science.gov (United States)

    Echternacht, Gary

    This paper outlines a methodology that school districts can use to enhance the presentation of district-wide testing program results to administrators, school boards, teachers, and the public. Based on John Tukey's two way analysis methodology, it involves fitting this model: test score equals overall plus year plus grade plus cohort plus…

  8. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted. copyright 1997 American Institute of Physics

  9. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted

  10. Swine influenza test results from animal health laboratories in Canada

    OpenAIRE

    Kloeze, Harold; Mukhi, Shamir N; Alexandersen, Soren

    2013-01-01

    Due to its infrastructure and partnerships the Canadian Animal Health Surveillance Network was able to rapidly collect test results from 9 Canadian laboratories that were conducting primary testing for influenza on swine-origin samples, in response to the threat posed by the pandemic H1N1 influenza virus in 2009.

  11. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  12. Profiling of drugs and environmental chemicals for functional impairment of neural crest migration in a novel stem cell-based test battery

    NARCIS (Netherlands)

    Zimmer, B.; Pallocca, G.; Dreser, N.; Foerster, S.; Waldmann, T.; Westerhout, J.; Julien, S.; Krause, K.H.; Van Thriel, C.; Hengstler, J.G.; Sachinidis, A.; Bosgra, S.; Leist, M.

    2014-01-01

    Developmental toxicity in vitro assays have hitherto been established as stand-alone systems, based on a limited number of toxicants. Within the embryonic stem cell-based novel alternative tests project, we developed a test battery framework that allows inclusion of any developmental toxicity assay

  13. Preliminary results of steel containment vessel model test

    Energy Technology Data Exchange (ETDEWEB)

    Luk, V.K.; Hessheimer, M.F. [Sandia National Labs., Albuquerque, NM (United States); Matsumoto, T.; Komine, K.; Arai, S. [Nuclear Power Engineering Corp., Tokyo (Japan); Costello, J.F. [Nuclear Regulatory Commission, Washington, DC (United States)

    1998-04-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11--12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented.

  14. Interim results from UO2 fuel oxidation tests in air

    International Nuclear Information System (INIS)

    An experimental program is being conducted at Pacific Northwest Laboratory (PNL) to extend the characterization of spent fuel oxidation in air. To characterize oxidation behavior of irradiated UO2, fuel oxidation tests were performed on declad light-water reactor spent fuel and nonirradited UO2 pellets in the temperature range of 135 to 2500C. These tests were designed to determine the important independent variables that might affect spent fuel oxidation behavior. The data from this program, when combined with the test results from other programs, will be used to develop recommended spent fuel dry-storage temperature limits in air. This report describes interim test results. The initial PNL investigations of nonirradiated and spent fuels identified the important testing variables as temperature, fuel burnup, radiolysis of the air, fuel microstructure, and moisture in the air. Based on these initial results, a more extensive statistically designed test matrix was developed to study the effects of temperature, burnup, and moisture on the oxidation behavior of spent fuel. Oxidation tests were initiated using both boiling-water reactor and pressurized-water reactor fuels from several different reactors with burnups from 8 to 34 GWd/MTU. A 105 R/h gamma field was applied to the test ovens to simulate dry storage cask conditions. Nonirradiated fuel was included as a control. This report describes experimental results from the initial tests on both the spent and nonirradiated fuels and results to date on the tests in a 105 R/h gamma field. 33 refs., 51 figs., 6 tabs

  15. Test emission of uranium hexafluoride in atmosphere. Results interpretation

    International Nuclear Information System (INIS)

    To permit the modelization of gaseous uranium hexafluoride behaviour in atmosphere, a validation test has been executed the 10 April 1987. The experimental conditions, the main results and a comparison with a diffusion model are given in this report

  16. Ecotoxicological assessment of organic wastes spread on land: Towards a proposal of a suitable test battery.

    Science.gov (United States)

    Huguier, Pierre; Manier, Nicolas; Chabot, Laure; Bauda, Pascale; Pandard, Pascal

    2015-03-01

    The land spreading of organic wastes in agriculture is a common practice in Europe, under the regulation of the Directive 86/278/EEC. One of the objectives of this Directive is to prevent harmful effects of organic wastes on soil, plants and animals. Despite this regulatory framework, there is still a lack of harmonized ecotoxicological test strategy to assess the environmental hazard of such wastes. The aim of this study was to provide a first step towards the a priori ecotoxicological assessment of organic wastes before their land use. For that purpose, nine different organic wastes were assessed using direct (i.e. terrestrial tests) and indirect (i.e. tests on water eluates) approaches, for a total of thirteen endpoints. Then, multivariate analyzes were used to discriminate the most relevant test strategy, among the application rates and bioassays used. From our results, a draft of test strategy was proposed, using terrestrial bioassays (i.e. earthworms and plants) and a concentration range between one and ten times the recommended application rates of organic wastes. PMID:25485958

  17. Pharmacogenetic allele nomenclature: International workgroup recommendations for test result reporting.

    Science.gov (United States)

    Kalman, L V; Agúndez, Jag; Appell, M Lindqvist; Black, J L; Bell, G C; Boukouvala, S; Bruckner, C; Bruford, E; Caudle, K; Coulthard, S A; Daly, A K; Tredici, Al Del; den Dunnen, J T; Drozda, K; Everts, R E; Flockhart, D; Freimuth, R R; Gaedigk, A; Hachad, H; Hartshorne, T; Ingelman-Sundberg, M; Klein, T E; Lauschke, V M; Maglott, D R; McLeod, H L; McMillin, G A; Meyer, U A; Müller, D J; Nickerson, D A; Oetting, W S; Pacanowski, M; Pratt, V M; Relling, M V; Roberts, A; Rubinstein, W S; Sangkuhl, K; Schwab, M; Scott, S A; Sim, S C; Thirumaran, R K; Toji, L H; Tyndale, R F; van Schaik, Rhn; Whirl-Carrillo, M; Yeo, Ktj; Zanger, U M

    2016-02-01

    This article provides nomenclature recommendations developed by an international workgroup to increase transparency and standardization of pharmacogenetic (PGx) result reporting. Presently, sequence variants identified by PGx tests are described using different nomenclature systems. In addition, PGx analysis may detect different sets of variants for each gene, which can affect interpretation of results. This practice has caused confusion and may thereby impede the adoption of clinical PGx testing. Standardization is critical to move PGx forward. PMID:26479518

  18. Influence of diet on the results of laboratory tests

    Directory of Open Access Journals (Sweden)

    Kinga Lis

    2013-12-01

    Full Text Available Blood and urine laboratory tests are necessary to diagnose the state of the patient. These tests are also helpful in the assessment of diet and nutritional status of the organism. It is recommended that both blood and urine for laboratory tests be collected in the morning, from fasting patients after an overnight rest. These conditions are defined as the standard conditions for collection of material for laboratory testing. Before testing, patients should follow their natural diet and avoid physical exertion, night work, long-distance travel, as well as consumption of alcohol and drugs. They should also reduce the consumption of synthetic vitamins and herbal remedies and other dietary supplements. Medications should be limited to those that are absolutely necessary. All of these factors can affect the results of laboratory tests.

  19. Results from the Astronomy Diagnostic Test National Project

    Science.gov (United States)

    Deming, G. L.

    2001-12-01

    During 2000 and 2001, the validity and reliability of the Astronomy Diagnostic Test Version 2.0 (ADT 2.0) were formally investigated through the Astronomy Diagnostic Test National Project. The ADT 2.0 was administered as a pre-test to 5346 students and as a post-test to 3842 students. Student test results were collected from 97 classes that ranged in size from 4 to 320 students with 30 states represented. The 68 professors participating in the ADT National Project taught classes at universities (54%), 4-year colleges (27%), and 2-year colleges (19%). The database was analyzed for reliability at the Ontario Institute for Studies in Education. A pre-test value for Cronbach's alpha of 0.65 and post-test value of 0.76 demonstrate an acceptable degree of internal consistency. The average score for the 44 participating professors who completed the ADT as experts was 98%. Face and content validity were established by combining results from the experts with feedback from 60 student interviews. Student results from the National Project yielded an average score of 32.4% for the pre-test and 47.3% for the post-test. There is a gender discrepancy in favor of males that persists in both the pre-test (11% points) and the post-test (12% points) scores. The variations across geographic distribution and institution types were not significant. In addition to the 21 content items, the ADT 2.0 has 12 student background questions enabling instructors to have a better understanding of who takes introductory astronomy. This research was supported by the National Science Foundation through grants REC-0089239 (GD) and DGE-9714489 (BH).

  20. Results of the ESA study on psychological selection of astronaut applicants for Columbus missions I: Aptitude testing

    Science.gov (United States)

    Fassbender, Christoph; Goeters, Klaus-Martin

    European participation in the Space Station Freedom brought about new challenges for the psychological selection of astronaut candidates, particularly in respect to specific demands of long duration space flights. For this reason existing selection criteria and methods were reassessed. On these grounds a study was undertaken applying a unique composition of aptitude tests to a group of 97 ESA scientists and engineers who are highly comparable to the expected astronaut applicants with respect to age and education. The tests assessed operational aptitudes such as logical reasoning, memory function, perception, spatial orientation, attention, psychomotor function, and multiple task capacity. The study goals were: 1) Verification of psychometric qualities and applicability of tests in a normative group; 2) Search for culture-fair tests by which multi-national groups can be examined; 3) Identification of test methods which consider general and special operational demands of long duration space flights. Based on the empirical findings a test battery was arranged for use in the selection of ESA astronaut applicants. Results showed that 16 out of the 18 employed tests have good psychometric qualities and differentiate reliably in the special group of testees. The meta structure of the test battery as described by a factorial analysis is presented. Applicability of tests was generally high. Tests were culture-fair, however, a relation between English language skills and test results was identified. Since most item material was language-free, this was explained with the importance of English language skills for the understanding of test instructions. Solutions to this effect are suggested.

  1. Nonlinear Dynamics Traction Battery Modeling

    OpenAIRE

    Szumanowski, Antoni

    2010-01-01

    The assumed method and effective model are very accurate according to error checking results of the NiMH and Li-Ion batteries. The modeling method is valid for different types of batteries. The model can be conveniently used for vehicle simulation because the battery model is accurately approximated by mathematical equations. The model provides the methodology for designing a battery management system and calculating the SOC. The influence of temperature on battery performance is analyzed acc...

  2. Field tests experience from 1.6MW/400kWh Li-ion battery energy storage system providing primary frequency regulation service

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Ioan; Stan, Ana-Irina; Teodorescu, Remus; Lærke, Rasmus; Kjær, Philip Carne

    Lithium-ion battery energy storage systems (BESSs) represent suitable alternatives to conventional generating units for providing primary frequency regulation on the Danish market. This paper presents aspects concerning the operation of the BESSs in the Danish energy market while providing upwards...... the BESS demonstrator located in Western Denmark and initial results are introduced and discussed. These measurements can be used to validate models for battery ageing during realistic operation or to develop the diagnostic tools for the BESS....

  3. The Placenta in Toxicology. Part IV: Battery of Toxicological Test Systems Based on Human Placenta

    OpenAIRE

    Göhner, Claudia; Svensson-Arvelund, Judit; Pfarrer, Christiane; Häger, Jan-Dirk; Faas, Marijke; Ernerudh, Jan; Cline, J. Mark; Dixon, Darlene; Buse, Eberhard; Markert, Udo R.

    2013-01-01

    This review summarizes the potential and also some limitations of using human placentas, or placental cells and structures for toxicology testing. The placenta contains a wide spectrum of cell types and tissues, such as trophoblast cells, immune cells, fibroblasts, stem cells, endothelial cells, vessels, glands, membranes, and many others. It may be expected that in many cases the relevance of results obtained from human placenta will be higher than those from animal models due to species spe...

  4. The placenta in toxicology. Part IV : Battery of toxicological test systems based on human placenta

    OpenAIRE

    Göhner, Claudia; Svensson-Arvelund, Judit; Pfarrer, Christiane; Häger, Jan-Dirk; Faas, Marijke; Ernerudh, Jan; Cline, J. Mark; Dixon, Darlene; Buse, Eberhard; Markert, Udo R.

    2014-01-01

    This review summarizes the potential and also some limitations of using human placentas, or placental cells and structures for toxicology testing. The placenta contains a wide spectrum of cell types and tissues, such as trophoblast cells, immune cells, fibroblasts, stem cells, endothelial cells, vessels, glands, membranes, and many others. It may be expected that in many cases the relevance of results obtained from human placenta will be higher than those from animal models due to species spe...

  5. Pharmacological evaluation of novel 5-HT 3 receptor antagonist, QCM-13 (N-cyclohexyl-3-methoxyquinoxalin-2-carboxamide as anti-anxiety agent in behavioral test battery

    Directory of Open Access Journals (Sweden)

    Deepali Gupta

    2015-01-01

    Full Text Available Objective: In the last few decades, serotonin type-3 (5-HT 3 receptor antagonists have been identified as potential targets for anxiety disorders. In preclinical studies, 5-HT 3 antagonists have shown promising antianxiety effects. In this study, a novel 5-HT 3 receptor antagonist, QCM-13(N-cyclohexyl-3-methoxyquinoxalin-2-carboxamide was evaluated for anxiolytic-like activity in rodent behavioral test battery. Materials and Methods: Mice were given QCM-13 (2 and 4 mg/kg, intraperitoneally [i.p.] or diazepam (2 mg/kg, i.p. or vehicle and after 30 min, mice were subjected to four validated behavioral test batteries viz. elevated plus maze, hole board, light-dark and open field tests. Interaction study of QCM-13 with m-chlorophenyl piperazine (mCPP (mCPP, a 5-HT 2A/2C receptor agonist, 1 mg/kg, i.p. and buspirone (BUS, a partial 5-HT 1A agonist, 10 mg/kg, i.p. were performed to assess the pharmacological mechanism of the drug. Results: QCM-13 expressed potential anxiolytic effect with significant (P < 0.05 increase in behavioral parameters measured in aforementioned preliminary models. Besides, QCM-13 was unable to reverse the anxiogenic effect of mCPP, but potentiated anxiolytic affect of BUS. Conclusion: The results suggest that QCM-13 can be a potential therapeutic candidate for the management of anxiety-like disorders and combination doses of novel 5-HT 3 receptor antagonist with standard anxiolytics may improve therapeutic efficacy.

  6. Alkaline quinone flow battery.

    Science.gov (United States)

    Lin, Kaixiang; Chen, Qing; Gerhardt, Michael R; Tong, Liuchuan; Kim, Sang Bok; Eisenach, Louise; Valle, Alvaro W; Hardee, David; Gordon, Roy G; Aziz, Michael J; Marshak, Michael P

    2015-09-25

    Storage of photovoltaic and wind electricity in batteries could solve the mismatch problem between the intermittent supply of these renewable resources and variable demand. Flow batteries permit more economical long-duration discharge than solid-electrode batteries by using liquid electrolytes stored outside of the battery. We report an alkaline flow battery based on redox-active organic molecules that are composed entirely of Earth-abundant elements and are nontoxic, nonflammable, and safe for use in residential and commercial environments. The battery operates efficiently with high power density near room temperature. These results demonstrate the stability and performance of redox-active organic molecules in alkaline flow batteries, potentially enabling cost-effective stationary storage of renewable energy. PMID:26404834

  7. Assessment of Galileo modal test results for mathematical model verification

    Science.gov (United States)

    Trubert, M.

    1984-01-01

    The modal test program for the Galileo Spacecraft was completed at the Jet Propulsion Laboratory in the summer of 1983. The multiple sine dwell method was used for the baseline test. The Galileo Spacecraft is a rather complex 2433 kg structure made of a central core on which seven major appendages representing 30 percent of the total mass are attached, resulting in a high modal density structure. The test revealed a strong nonlinearity in several major modes. This nonlinearity discovered in the course of the test necessitated running additional tests at the unusually high response levels of up to about 21 g. The high levels of response were required to obtain a model verification valid at the level of loads for which the spacecraft was designed. Because of the high modal density and the nonlinearity, correlation between the dynamic mathematical model and the test results becomes a difficult task. Significant changes in the pre-test analytical model are necessary to establish confidence in the upgraded analytical model used for the final load verification. This verification, using a test verified model, is required by NASA to fly the Galileo Spacecraft on the Shuttle/Centaur launch vehicle in 1986.

  8. Results of recent ORNL fission product release tests

    International Nuclear Information System (INIS)

    The effects of time, high temperature, and atmosphere were explored in ORNL tests VI-2, VI-3, and VI-4. These tests were performed using vertically oriented segments of Zircaloy-clad UO2 fuel that had been irradiated to ∼42 MWd/kg U in the Belgian BR3 reactor. Tests in steam were conducted at temperature plateaus of 2,000, 2,300, and 2,700 K; test VI-4 was conducted in a hydrogen-helium atmosphere at 2,450 K. Results of test VI-2, which were run for 60 min at 2,300 K, showed that 63% of the fission product cesium had been released. The release rate for cesium, expressed as a fraction of the remaining inventory released per minute, decreased tenfold during the test. The fuel in test VI-3 was heated at 2,000 and 2,700 K for 20 min at each temperature. Essentially 100% of the cesium, krypton, and antimony were released. No measurable release of either cerium or europium was observed. In both VI-2 and VI-3, the steam oxidation of the Zircaloy cladding followed the Urbanick-Heidrick rate data. Modeling work shows that Booth diffusion coefficients (random diffusion from fuel grains) correlate all of the test results very well

  9. Cement/bentonite interaction. Results from 16 month laboratory tests

    International Nuclear Information System (INIS)

    The work concerns possible bentonite clay mineral alteration in constructions with bentonite in close contact with cement, and the effect of such changes on bentonite buffer properties. The investigation comprises a 16 months laboratory test series with hydrothermal cell tests, percolation tests and diffusion tests. MX-80 Wyoming bentonite was used in all tests. Two types of artificial cement pore water solutions were used in the percolation and diffusion tests. The swelling pressure and the hydraulic conductivity were measured continuously in the percolation tests. After termination, the clay was analyzed with respect to changes in element distribution, mineralogy and shear strength. The water solutions were analyzed with respect to pH, cations and major anions. The results concerning chemical and mineralogical changes are in summary: Ion exchange in the montmorillonite until equilibrium with cement pore-water ions was reached; Increase in cation exchange capacity; Dissolution of original cristobalite; Increase in quartz content; Minor increase in illite content; Minor formation of chlorite; Formation of CSH(I); Wash away of CSH-gel into surrounding water. A large decrease in swelling pressure and a moderate increase in hydraulic conductivity were recorded in the samples percolated by SULFACEM pore-water solution. The mineralogical alterations only concerned a minor part of the total bentonite mass and the changes in physical properties were therefore most likely due to the replacement of the original charge balancing cation by cement pore-water cations. Comparisons between the current test result and results from 4 month tests indicate that the rates of illite and chlorite formation were reduced during the tests. The presence of zeolites in the clay could not be ensured. However, the discovery of CSH material is important since CSH is expected to precede the formation of zeolites

  10. Results from Testing of Two Rotary Percussive Drilling Systems

    Science.gov (United States)

    Kriechbaum, Kristopher; Brown, Kyle; Cady, Ian; von der Heydt, Max; Klein, Kerry; Kulczycki, Eric; Okon, Avi

    2010-01-01

    The developmental test program for the MSL (Mars Science Laboratory) rotary percussive drill examined the e ect of various drill input parameters on the drill pene- tration rate. Some of the input parameters tested were drill angle with respect to gravity and percussive impact energy. The suite of rocks tested ranged from a high strength basalt to soft Kaolinite clay. We developed a hole start routine to reduce high sideloads from bit walk. The ongoing development test program for the IMSAH (Integrated Mars Sample Acquisition and Handling) rotary percussive corer uses many of the same rocks as the MSL suite. An additional performance parameter is core integrity. The MSL development test drill and the IMSAH test drill use similar hardware to provide rotation and percussion. However, the MSL test drill uses external stabilizers, while the IMSAH test drill does not have external stabilization. In addition the IMSAH drill is a core drill, while the MSL drill uses a solid powdering bit. Results from the testing of these two related drilling systems is examined.

  11. Testing Result Statistics-Based Rapid Testing Method for Safety-Critical System

    Institute of Scientific and Technical Information of China (English)

    Zhi-Yao Deng; Nan Sang

    2008-01-01

    Safety-critical system (SCS) has highly demand for dependability, which requires plenty of resource to ensure that the system under test (SUT) satisfies the dependability requirement. In this paper, a new SCS rapid testing method is proposed to improve SCS adaptive dependability testing. The result of each test execution is saved in calculation memory unit and evaluated as an algorithm model. Then the least quantity of scenario test case for next test execution will be calculated according to the promised SUT's confidence level. The feedback data are generated to weight controller as the guideline for the further testing. Finally, a compre- hensive experiment study demonstrates that this adaptive testing method can really work in practice. This rapid testing method, testing result statistics-based adaptive control, makes the SCS dependability testing much more effective.

  12. Cold vacuum drying proof of performance (first article testing) test results

    International Nuclear Information System (INIS)

    This report presents and details the test results of the first of a kind process referred to as Cold Vacuum Drying (CVD). The test results are compiled from several months of testing of the first process equipment skid and ancillary components to de-water and dry Multi-Canister Overpacks (MCO) filled with Spent Nuclear Fuel (SNF). The tests results provide design verifications, equipment validations, model validation data, and establish process parameters

  13. 电动汽车电池箱检测工装的结构设计%Structure Design of Battery Box Test Equipment of Electric Car

    Institute of Scientific and Technical Information of China (English)

    崔庆东; 丁丽平; 郭炎杰; 李明道

    2013-01-01

    T he current electric vehicle battery boxes are made of manual inspection and have no battery or load block w hen detectingin the actual situation .In case of this ,this article presents a fully automatic battery box testing equipmentand a detailed statement of the test fixture design process and the typical program .By ana-lysing the advantages and disadvantages of the various options ,it ultimately designs a generic battery box testing automation equipment in this article .T he device implements the electric vehicle battery box automatic testing and evaluation ,w hich can not only reduce the labors intensity ,improve the reliability of the product testing ,credibility and the pre -qualified rate of battery box ,but also greatlyimprove the working efficiency and fill the gap of the industry .%针对目前电动汽车动力电池箱均采用人工检测且检测时不匹配电池或载重块的实际情况,提出了一种全自动化的电池箱检测工装,并详细陈述了检测工装的设计过程及典型方案,通过分析各个方案的优缺点,最终设计出了一种通用的自动化电池箱检测工装;该检测工装实现了电动汽车电池箱自动化检测与评估,不仅减轻了工人的劳动强度,提高了产品检测的可靠性、可信性和电池箱出厂合格率,工作效率也得到了很大的提升,为行业填补了空白。

  14. Indeterminate and discrepant rapid HIV test results in couples' HIV testing and counselling centres in Africa

    Directory of Open Access Journals (Sweden)

    Boeras Debrah I

    2011-04-01

    Full Text Available Abstract Background Many HIV voluntary testing and counselling centres in Africa use rapid antibody tests, in parallel or in sequence, to establish same-day HIV status. The interpretation of indeterminate or discrepant results between different rapid tests on one sample poses a challenge. We investigated the use of an algorithm using three serial rapid HIV tests in cohabiting couples to resolve unclear serostatuses. Methods Heterosexual couples visited the Rwanda Zambia HIV Research Group testing centres in Kigali, Rwanda, and Lusaka, Zambia, to assess HIV infection status. Individuals with unclear HIV rapid antibody test results (indeterminate or discrepant results were asked to return for repeat testing to resolve HIV status. If either partner of a couple tested positive or indeterminate with the screening test, both partners were tested with a confirmatory test. Individuals with indeterminate or discrepant results were further tested with a tie-breaker and monthly retesting. HIV-RNA viral load was determined when HIV status was not resolved by follow-up rapid testing. Individuals were classified based on two of three initial tests as "Positive", "Negative" or "Other". Follow-up testing and/or HIV-RNA viral load testing determined them as "Infected", "Uninfected" or "Unresolved". Results Of 45,820 individuals tested as couples, 2.3% (4.1% of couples had at least one discrepant or indeterminate rapid result. A total of 65% of those individuals had follow-up testing and of those individuals initially classified as "Negative" by three initial rapid tests, less than 1% were resolved as "Infected". In contrast, of those individuals with at least one discrepant or indeterminate result who were initially classified as "Positive", only 46% were resolved as "Infected", while the remainder was resolved as "Uninfected" (46% or "Unresolved" (8%. A positive HIV serostatus of one of the partners was a strong predictor of infection in the other partner as 48

  15. Designs and test results for three new rotational sensors

    Science.gov (United States)

    Jedlicka, P.; Kozak, J.T.; Evans, J.R.; Hutt, C.R.

    2012-01-01

    We discuss the designs and testing of three rotational seismometer prototypes developed at the Institute of Geophysics, Academy of Sciences (Prague, Czech Republic). Two of these designs consist of a liquid-filled toroidal tube with the liquid as the proof mass and providing damping; we tested the piezoelectric and pressure transduction versions of this torus. The third design is a wheel-shaped solid metal inertial sensor with capacitive sensing and magnetic damping. Our results from testing in Prague and at the Albuquerque Seismological Laboratory of the US Geological Survey of transfer function and cross-axis sensitivities are good enough to justify the refinement and subsequent testing of advanced prototypes. These refinements and new testing are well along.

  16. Depressurisation studies. Phase 2: results of Tests 127 and 128

    International Nuclear Information System (INIS)

    A basic experimental programme involving the sudden depressurisation of a simple pipe system containing water at 3.45 to 17.24MPa pressure and temperature in the range of 200 to 2500C has been concluded. Measurements were made of the transient density, pressure, and temperature variations in a two phase fluid in the system during discharge. Phase 1 tests investigated blowdown from straight pipes 4m long with constant internal diameters of 73 and 32 mm. Phase 2 tests incorporated a reservoir added to the 32mm pipe. In this, the second of three reports on Phase 2 tests, the test assembly, instrumentation and experimental procedure are briefly described. The conditions and results are reported for two of the tests in which the liquid in the long discharge pipe was initially subcooled by 100C and 150C while the reservoir was at saturation conditions with a steam dome present. (UK)

  17. Depressurisation studies. Phase 2: results of Tests 115 and 130

    International Nuclear Information System (INIS)

    Investigations into phenomena which might influence the course of a loss-of-coolant accident in a water reactor system have included depressurization studies of geometrically simple systems from typical reactor operating conditions. Tests on a simple pipe system containing water at pressures between 3.45 and 17.24 MPa and temperatures in the range of 2000 to 2500C have been concluded. Measurements were made of transient density, pressure and temperature variations in a two-phase fluid system during discharge. Phase 1 tests, previously reported, investigated blowdown from straight pipes 4m long with constant internal diameters of 73 and 32 mm. Phase 2 tests incorporated a reservoir added to the 32mm dia pipe. This report is the first of three giving results of Phase 2 tests. It also includes a description of the test assembly, the instrumentation and the experimental procedure. (author)

  18. Automated Testing Infrastructure and Result Comparison for Geodynamics Codes

    Science.gov (United States)

    Heien, E. M.; Kellogg, L. H.

    2013-12-01

    The geodynamics community uses a wide variety of codes on a wide variety of both software and hardware platforms to simulate geophysical phenomenon. These codes are generally variants of finite difference or finite element calculations involving Stokes flow or wave propagation. A significant problem is that codes of even low complexity will return different results depending on the platform due to slight differences in hardware, software, compiler, and libraries. Furthermore, changes to the codes during development may affect solutions in unexpected ways such that previously validated results are altered. The Computational Infrastructure for Geodynamics (CIG) is funded by the NSF to enhance the capabilities of the geodynamics community through software development. CIG has recently done extensive work in setting up an automated testing and result validation system based on the BaTLab system developed at the University of Wisconsin, Madison. This system uses 16 variants of Linux and Mac platforms on both 32 and 64-bit processors to test several CIG codes, and has also recently been extended to support testing on the XSEDE TACC (Texas Advanced Computing Center) Stampede cluster. In this work we overview the system design and demonstrate how automated testing and validation occurs and results are reported. We also examine several results from the system from different codes and discuss how changes in compilers and libraries affect the results. Finally we detail some result comparison tools for different types of output (scalar fields, velocity fields, seismogram data), and discuss within what margins different results can be considered equivalent.

  19. Analysis of SCTF/CCTF counterpart test results

    International Nuclear Information System (INIS)

    Slab Core Test Facility (SCTF) and Cylindrical Core Test Facility (CCTF) are large scale experimental facilities of Japan Atomic Energy Research Institute (JAERI) for the investigation of reflooding behavior during a postulated loss-of-coolant accident (LOCA) in PWRs. Although the flow area scaling ratios of both facilities to a 1,000 MWe class PWR are the same and 1/21.4, the SCTF has the same core width as the radius of the reference PWR while the CCTF has a 1/4.5 times shorter core radius. Therefore, a few SCTF/CCTF counterpart tests were conducted in order to investigate the difference in core reflooding behavior between in the SCTF and CCTF tests as well as the effect of core radial length on core two-dimensional thermo-hydrodynamic behavior. This report present the test results and an analysis on them. Major results obtained are: (1) Taking account of the differences in test conditions and facility design, core reflooding behavior is considered to be similar between the SCTF and the CCTF test. Main difference of the facility design is in the effective core flow area and this is considered to result in the difference in core water accumulation behavior. (2) The effect of core radial length on core two-dimensional thermo-hydrodynamic behavior has been observed to be significant and heat transfer enhancement or degradation in radial direction is more significant for the longer radius core. (3) In addition, where the core power varies significantly in the radial direction, significant heat transfer enhancement has been observed in the higher power bundle during the LPCI period. Also, in the peripheral region, heat transfer degradation has been observed more significantly in the outer bundle even they have the same bundle power. (4) Magnitude of these heat transfer enhancement or degradation was larger at the higher elevation than the midplane level in the SCTF test, whereas smaller in the CCTF test. (author)

  20. Tensile and fracture toughness test results of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Chaouadi, R.; Moons, F.; Puzzolante, J.L. [Centre d`Etude de l`Energie Nucleaire, Mol (Belgium)

    1998-01-01

    Tensile and fracture toughness test results of four Beryllium grades are reported here. The flow and fracture properties are investigated by using small size tensile and round compact tension specimens. Irradiation was performed at the BR2 material testing reactor which allows various temperature and irradiation conditions. The fast neutron fluence (>1 MeV) ranges between 0.65 and 2.45 10{sup 21} n/cm{sup 2}. In the meantime, un-irradiated specimens were aged at the irradiation temperatures to separate if any the effect of temperature from irradiation damage. Test results are analyzed and discussed, in particular in terms of the effects of material grade, test temperature, thermal ageing and neutron irradiation. (author)

  1. Test results of Ya-21u thermionic space power system

    International Nuclear Information System (INIS)

    The Soviet-made TOPAZ-II space nuclear power system unit designated Ya-21u underwent a total of 15 tests both in the Union of Soviet Socialist Republic (USSR) (1989--1990) and in the US (August 1993 to March 1995) for a cumulative test/operation time of 7681 h at conditions far exceeding design limits. These tests included steady-state operation at different power levels, fast start-ups and power optimizations, and shock and vibration tests. Test results are presented and analyzed. Results indicate a gradual change in the performance parameters such as the optimum cesium pressure and optimum load voltage. The electric power and conversion efficiency of the unit at an input thermal power of 105 kW decreased from 3.7 kW (electric) and 4% in the test in the USSR to 2.13 kW (electric) and 2.3% in the last test in the US. A discussion and qualitative assessment of potential causes of the performance changes of the Ya-21u unit are given

  2. Research and development of a phosphoric acid fuel cell/battery power source integrated in a test-bed bus. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-30

    This project, the research and development of a phosphoric acid fuel cell/battery power source integrated into test-bed buses, began as a multi-phase U.S. Department of Energy (DOE) project in 1989. Phase I had a goal of developing two competing half-scale (25 kW) brassboard phosphoric acid fuel cell systems. An air-cooled and a liquid-cooled fuel cell system were developed and tested to verify the concept of using a fuel cell and a battery in a hybrid configuration wherein the fuel cell supplies the average power required for operating the vehicle and a battery supplies the `surge` or excess power required for acceleration and hill-climbing. Work done in Phase I determined that the liquid-cooled system offered higher efficiency.

  3. Results of the Cryogenic Testing of the SNS Prototype Cryomodule

    Energy Technology Data Exchange (ETDEWEB)

    I.E. Campisi; G. Ciovati; E. Daly; K. Davis; J.R. Delayen; M. Drury; P. Kneisel; J. Mammosser; T. Powers; J. Preble; C.E. Reece; M. Stirbet; H. Wang; K. Wilson (Jefferson Lab); S. Smee (SNS)

    2002-08-01

    Jefferson Lab has developed a prototype of the medium beta SNS cryomodule. Tests were recently performed on the module, which includes three 805 MHz cavities of beta=0.61, with coaxial power couplers and frequency tuners (mechanical and piezoelectric). The cavities exceeded accelerating gradients of 16 MV/m (design value 10.5 MV/m) with Q{sub 0}'s of about 10{sup 10} at the design field. One of the power couplers has been tested up to peak powers of over 700 kW. Results of the tests are reported in this paper.

  4. Results of the Cryogenic Testing of the SNS Prototype Cryomodule

    International Nuclear Information System (INIS)

    Jefferson Lab has developed a prototype of the medium beta SNS cryomodule. Tests were recently performed on the module, which includes three 805 MHz cavities of beta=0.61, with coaxial power couplers and frequency tuners (mechanical and piezoelectric). The cavities exceeded accelerating gradients of 16 MV/m (design value 10.5 MV/m) with Q0's of about 1010 at the design field. One of the power couplers has been tested up to peak powers of over 700 kW. Results of the tests are reported in this paper

  5. Construction details and test results from RHIC sextupoles

    International Nuclear Information System (INIS)

    Four 8 cm aperture sextupoles have been built at BNL to verify the magnetic performance of this magnet in the RHIC installation. Two significantly different mechanical configurations have been designed, and two magnets of each design have been built, and successfully tested, and have exceeded the required minimum quench current by a substantial margin. This report describes the assembly details of the second configuration, which is the final production configuration. In addition the first industry built production sextupole has been delivered and tested. This report presents the results of quench tests on all 5 magnets and field measurements on the first production sextupole

  6. Wellbore inertial navigation system (WINS) software development and test results

    Energy Technology Data Exchange (ETDEWEB)

    Wardlaw, R. Jr.

    1982-09-01

    The structure and operation of the real-time software developed for the Wellbore Inertial Navigation System (WINS) application are described. The procedure and results of a field test held in a 7000-ft well in the Nevada Test Site are discussed. Calibration and instrumentation error compensation are outlined, as are design improvement areas requiring further test and development. Notes on Kalman filtering and complete program listings of the real-time software are included in the Appendices. Reference is made to a companion document which describes the downhole instrumentation package.

  7. DWPF Sampling Device Development Test Results and Design Recommendation

    Energy Technology Data Exchange (ETDEWEB)

    Wilds, G.W.

    2001-07-17

    This report summarizes the development and testing of a sample device for the DWPF sample cells. The clamp actuated manual Hydraguard valve used in conjunction with the concentric needle fill device is recommended for use in the DWPF. This is based on test results which indicate that this sampler is capable of obtaining samples within five percent of the solids concentration of the process stream at flow rates from 0.5 to 3.5 gpm.

  8. Test Beam Results of a 3D Diamond Detector

    CERN Document Server

    Dunser, Marc

    2015-01-01

    3D pixel technology has been used successfully in the past with silicon detectors for tracking applications. Recently, a first prototype of the same 3D technology has been produced on a chemical vapour deposited single-crystal diamond sensor. This device has been subsequently tested in a beam test at CERN’s SPS accelerator in a beam of 120 GeV protons. Details on the production and results of testbeam data are presented.

  9. Dividend Policy and Inflation In Australia: Results From Cointegration Tests

    OpenAIRE

    Tobias Basse

    2009-01-01

    This paper examines the relationship between dividends and inflation in Australia by testing for cointegration between these two variables. The results of the tests indicate that inflation is contributing to dividend growth. This finding can be interpreted in different ways. Trying to follow a dividend policy which is perceived to be optimal Australian firms may, for example, believe that there is a desirable level of real dividend income to be paid out to their investors. A second possible i...

  10. First Test Results of the 4-ROD Crab Cavity

    CERN Document Server

    Ambattu, P; Burt, G; Calaga, R; Capatina, O; Calatroni, S; Ciapala, E; Doherty, D; Ferreira, L; Jensen, E; Hall, B; Lingwood, C; Maesen, P; Mongelluzzo, A; Renaglia, T; Therasse, M

    2013-01-01

    The first compact prototype crab cavity with the 4rod geometry has undergone surface treatment and cold testing. Due to the complex geometry and unique fabrication procedure, RF validation of the field at beyond the nominal operating voltage at a sufficiently high Q0 is an important pre-requisite. Preliminary results of the first cold tests are presented along with cavity performance at different stages of the cavity processing is described.

  11. Population normative data for the 10/66 Dementia Research Group cognitive test battery from Latin America, India and China: a cross-sectional survey

    Directory of Open Access Journals (Sweden)

    Yang Fang

    2009-08-01

    Full Text Available Abstract Background 1 To report site-specific normative values by age, sex and educational level for four components of the 10/66 Dementia Research Group cognitive test battery; 2 to estimate the main and interactive effects of age, sex, and educational level by site; and 3 to investigate the effect of site by region and by rural or urban location. Methods Population-based cross-sectional one phase catchment area surveys were conducted in Cuba, Dominican Republic, Venezuela, Peru, Mexico, China and India. The protocol included the administration of the Community Screening Instrument for Dementia (CSI 'D', generating the COGSCORE measure of global function, and the Consortium to Establish a Registry for Alzheimer's Disease (CERAD verbal fluency (VF, word list memory (WLM, immediate recall and recall (WLR, delayed recall tests. Only those free of dementia were included in the analysis. Results Older people, and those with less education performed worse on all four tests. The effect of sex was much smaller and less consistent. There was a considerable effect of site after accounting for compositional differences in age, education and sex. Much of this was accounted for by the effect of region with Chinese participants performing better, and Indian participants worse, than those from Latin America. The effect of region was more prominent for VF and WLM than for COGSCORE and WLR. Conclusion Cognitive assessment is a basic element for dementia diagnosis. Age- and education-specific norms are required for this purpose, while the effect of gender can probably be ignored. The basis of cultural effects is poorly understood, but our findings serve to emphasise that normative data may not be safely generalised from one population to another with quite different characteristics. The minimal effects of region on COGSCORE and WLR are reassuring with respect to the cross-cultural validity of the 10/66 dementia diagnosis, which uses only these elements of the 10

  12. Thermal Analysis of Low Layer Density Multilayer Insulation Test Results

    Science.gov (United States)

    Johnson, Wesley L.

    2011-01-01

    Investigation of the thermal performance of low layer density multilayer insulations is important for designing long-duration space exploration missions involving the storage of cryogenic propellants. Theoretical calculations show an analytical optimal layer density, as widely reported in the literature. However, the appropriate test data by which to evaluate these calculations have been only recently obtained. As part of a recent research project, NASA procured several multilayer insulation test coupons for calorimeter testing. These coupons were configured to allow for the layer density to be varied from 0.5 to 2.6 layer/mm. The coupon testing was completed using the cylindrical Cryostat-l00 apparatus by the Cryogenics Test Laboratory at Kennedy Space Center. The results show the properties of the insulation as a function of layer density for multiple points. Overlaying these new results with data from the literature reveals a minimum layer density; however, the value is higher than predicted. Additionally, the data show that the transition region between high vacuum and no vacuum is dependent on the spacing of the reflective layers. Historically this spacing has not been taken into account as thermal performance was calculated as a function of pressure and temperature only; however the recent testing shows that the data is dependent on the Knudsen number which takes into account pressure, temperature, and layer spacing. These results aid in the understanding of the performance parameters of MLI and help to complete the body of literature on the topic.

  13. Gelled-electrolyte batteries for electric vehicles

    Science.gov (United States)

    Tuphorn, Hans

    Increasing problems of air pollution have pushed activities of electric vehicle projects worldwide and in spite of projects for developing new battery systems for high energy densities, today lead/acid batteries are almost the single system, ready for technical usage in this application. Valve-regulated lead/acid batteries with gelled electrolyte have the advantage that no maintenance is required and because the gel system does not cause problems with electrolyte stratification, no additional appliances for central filling or acid addition are required, which makes the system simple. Those batteries with high density active masses indicate high endurance results and field tests with 40 VW-CityStromers, equipped with 96 V/160 A h gel batteries with thermal management show good results during four years. In addition, gelled lead/acid batteries possess superior high rate performance compared with conventional lead/acid batteries, which guarantees good acceleration results of the car and which makes the system recommendable for application in electric vehicles.

  14. Spent fuel drying system test results (first dry-run)

    International Nuclear Information System (INIS)

    The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks in the basin have been detected and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site. Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL) on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of the first dry-run test, which was conducted without a fuel element. The empty test apparatus was subjected to a combination of low- and high-temperature vacuum drying treatments that were intended to mimic, wherever possible, the fuel treatment strategies of the IPS. The data from this dry-run test can serve as a baseline for the first two fuel element tests, 1990 (Run 1) and 3128W (Run 2). The purpose of this dry-run was to establish the background levels of hydrogen in the system, and the hydrogen generation and release characteristics attributable to the test system without a fuel element present. This test also serves to establish the background levels of water in the system and the water release characteristics. The system used for the drying test series was the Whole Element Furnace Testing System, described in Section 2.0, which is located in the Postirradiation Testing Laboratory (PTL, 327 Building). The test conditions and methodology are given in section 3.0, and the experimental

  15. Biogas plasticization coupled anaerobic digestion: batch test results.

    Science.gov (United States)

    Schimel, Keith A

    2007-06-01

    Biogas has unique properties for improving the biodegradability of biomass solids during anaerobic digestion (AD). This report presents batch test results of the first investigation into utilizing biogas plasticization to "condition" organic polymers during active digestion of waste activated sludge (WAS). Preliminary design calculations based on polymer diffusion rate limitation are presented. Analysis of the 20 degrees C batch test data determined the first order (k(1)) COD conversion coefficient to be 0.167 day(-1) with a maximum COD utilization rate of 11.25 g L(-1) day(-1). Comparison of these batch test results to typical conventional AD performance parameters showed orders of magnitude improvement. These results show that biogas plasticization during active AD could greatly improve renewable energy yields from biomass waste materials such as MSW RDF, STP sludges, food wastes, animal manure, green wastes, and agricultural crop residuals. PMID:17054122

  16. Patch Test Results in Patients with Allergic Contact Dermatitis / Mucositis

    Directory of Open Access Journals (Sweden)

    Özlem Su

    2008-05-01

    Full Text Available Background and Design: The aims of our study were to determine the frequency of positive patch reactions and the most common allergens in patients with allergic contact dermatitis (ACD and/or mucositis(M who underwent with T.R.U.E. “Thin-layer Rapid-Use Epicutaneous” test and evaluate supplemantal series used with T.R.U.E. test effect on patch test results.Material and Method: In this study 161 ACD, 5 ACM, 1 ACD and ACM were enrolled. While 139 of all patients were patch tested with T.R.U.E. test alone,out of 28 patients were tested for T.R.U.E. test and also with supplemental series that included textile colours (9 of tested patients, plastic and glues (9, dental screening (6, backery (2, cosmetic (1 and plastic and glues and dental screening (1. Supplemental series were chosen according to patient’s occupation and clinic presentation. The data from our patients were analyzed as percentage. The relationship between contact sensitization and atopic status was evaluated with Yate’s correlation x2 test.Results: Eighty-six male, 81 female were taken into this study. The median age was 36.5.While 25.9% of 139 patients tested with T.R.U.E. test alone,46.4% of 28 patients applied supplemental series in addition to T.R.U.E. test showed positive reaction to one or more allergens. The most common allergens were nickel sulphate (14.4%, potassium dichromate (4.8%, fragrance mix (2.9% and colophony (2.9%. The most common supplemental allergens were octil gallat (50% in bakery and copper sulphate, goldsodiumthiosulphate (42.8% in dental screening. Positive patch reactions were detected 83.3% in 6 patients with AKM, 80% of these positive reactions was againts dental screening. The rate of contact sensitization between atopics and non-atopics was not significant (p>0.05. Conclusion: We suggest in presence of mucositis and/or occupational dermatoses using supplemental series in addition to T.R.U.E. test would be more beneficial in identifing the

  17. The use of a tracking test battery in the quantitative evaluation of neurological function

    Science.gov (United States)

    Repa, B. S.

    1973-01-01

    A number of tracking tasks that have proven useful to control engineers and psychologists measuring skilled performance have been evaluated for clinical use. Normal subjects as well as patients with previous diagnoses of Parkinson's disease, multiple sclerosis, and cerebral palsy were used in the evaluation. The tests that were studied included step tracking, random tracking, and critical tracking. The results of the present experiments encourage the continued use of tracking tasks as assessment precedures in a clinical environment. They have proven to be reliable, valid, and sensitive measures of neurological function.

  18. The Harvard Beat Assessment Test (H-BAT): a battery for assessing beat perception and production and their dissociation

    Science.gov (United States)

    Fujii, Shinya; Schlaug, Gottfried

    2013-01-01

    Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session. PMID:24324421

  19. The Harvard Beat Assessment Test (H-BAT: A Battery for Assessing Beat Perception and Production and their Dissociation

    Directory of Open Access Journals (Sweden)

    Gottfried Schlaug

    2013-11-01

    Full Text Available Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT, a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: 1 music tapping test (MTT, 2 beat saliency test (BST, 3 beat interval test (BIT, and 4 beat finding and interval test (BFIT. MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual’s ability to perceive and produce a beat within a single session.

  20. Lifespan Test Method for LiMn2 O4 Traction Batteries%锰酸锂动力电池寿命测试方法

    Institute of Scientific and Technical Information of China (English)

    时玮; 张言茹; 陈大分; 姜久春; 姜君; 梁彦

    2015-01-01

    以北京奥运会用锰酸锂电池为对象,通过电池的实际运行环境和电池容量衰退多种影响因素的分析,从充放电倍率应力、温度应力和放电深度应力3方面进行与实际运行环境等效的应力条件下的电池寿命测试。利用拟合的衰退数据得到了锂离子动力电池的寿命模型参数,利用线性累积法简化了电池容量衰退模型,提出了一种面向不同实际应用场合的电池寿命测试方法。与模拟混合四季温度的电池寿命数据对比验证了该简化模型的有效性,它有效缩短了电池寿命测试周期。%[ Abstract] With the LiMn2 O4 battery used as demonstration in Beijing Olympic Games as object, through the analyses on the practical operation environment of battery and various influencing factors of battery capacity fa-ding, a battery lifespan test under the stress condition equivalent to real operation environment is conducted from three aspects, i. e. the stresses of charge/discharge current rate, temperature and the depth of discharge. Then the capacity fading data fitted is used to obtain the lifespan model parameters of lithium-ion battery, linear cumulative method is used to simplify battery capacity fading model, and a battery lifespan test method for different practical application occasions is proposed. The comparison between the battery lifespan data obtained and that with the scheme simulating mixed four-season temperature verifies the effectiveness of simplified model, which effectively re-duce the test cycle of battery lifespan.

  1. Evaluation of the screening test results before marriage

    Directory of Open Access Journals (Sweden)

    Süleyman Durmaz

    2011-09-01

    Full Text Available Objectives: Human immunodeficiency virus (HIV, Hepatitis B and Hepatitis C viruses and Treponema pallidum are parenterally and sexually transmitted infection agents. Screening test is made before marriage to pre-marital couples legally under the relevant legislation and legal procedures in our country; applicants are evaluated in terms of sexually transmitted diseases. The aim of this study is to evaluate pre-marital test results for HBsAg, anti-HCV, anti-HIV I/II and Treponema pallidum.Materials and methods: To make screening test before marriage, randomized 117 patients who were applied to Kızıltepe General Hospital of Infectious Diseases and Clinical Microbiology, were included in this study between January 2011 and March 2011. Of these patients, 64 were women (average age 24.7±5.7, and 55 were males (mean age 24.7±4.7. HBsAg, anti-HCV and anti-HIV I/II tests of the patients were studied by macro-ELISA device (ECIQ Vitros, Ortho Clinical Diagnostics, USA, screening of anti-Treponema pallidum IgG, IgA and IgM antibodies were studied by immunochromatographic rapid test (syphilis syphilis 3.0, Standard Diagnostics, inc. Korea.Results: Of the 119 patients, five patients (4.2% were positive for HBsAg (3 male and 2 female. Anti-HCV, anti-HIV I/II and anti-Treponema pallidum antibodies were negative in all patients.Conclusion: HBsAg test result which was obtained in present study has been found consistent with HBsAg positivity rate in our region. As a result of screening test that was done before marriage will continue to believe that the increased importance of the prevention of sexually transmitted diseases. J Clin Exp Invest 2011; 2 (3: 292-294.

  2. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2013-05-29

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and

  3. Ecological risk assessment of organic waste amendments using the species sensitivity distribution from a soil organisms test battery

    International Nuclear Information System (INIS)

    Safe amendment rates (the predicted no-effect concentration or PNEC) of seven organic wastes were estimated from the species sensitivity distribution of a battery of soil biota tests and compared with different realistic amendment scenarios (different predicted environmental concentrations or PEC). None of the wastes was expected to exert noxious effects on soil biota if applied according either to the usual maximum amendment rates in Europe or phosphorus demands of crops (below 2 tonnes DM ha-1). However, some of the wastes might be problematic if applied according to nitrogen demands of crops (above 2 tonnes DM ha-1). Ammonium content and organic matter stability of the studied wastes are the most influential determinants of the maximum amendment rates derived in this study, but not pollutant burden. This finding indicates the need to stabilize wastes prior to their reuse in soils in order to avoid short-term impacts on soil communities. - Ecological risk assessment of organic waste amendments

  4. Functional and operational requirements document : building 1012, Battery and Energy Storage Device Test Facility, Sandia National Laboratories, New Mexico.

    Energy Technology Data Exchange (ETDEWEB)

    Johns, William H.

    2013-11-01

    This report provides an overview of information, prior studies, and analyses relevant to the development of functional and operational requirements for electrochemical testing of batteries and energy storage devices carried out by Sandia Organization 2546, Advanced Power Sources R&D. Electrochemical operations for this group are scheduled to transition from Sandia Building 894 to a new Building located in Sandia TA-II referred to as Building 1012. This report also provides background on select design considerations and identifies the Safety Goals, Stakeholder Objectives, and Design Objectives required by the Sandia Design Team to develop the Performance Criteria necessary to the design of Building 1012. This document recognizes the Architecture-Engineering (A-E) Team as the primary design entity. Where safety considerations are identified, suggestions are provided to provide context for the corresponding operational requirement(s).

  5. CSI computer system/remote interface unit acceptance test results

    Science.gov (United States)

    Sparks, Dean W., Jr.

    1992-01-01

    The validation tests conducted on the Control/Structures Interaction (CSI) Computer System (CCS)/Remote Interface Unit (RIU) is discussed. The CCS/RIU consists of a commercially available, Langley Research Center (LaRC) programmed, space flight qualified computer and a flight data acquisition and filtering computer, developed at LaRC. The tests were performed in the Space Structures Research Laboratory (SSRL) and included open loop excitation, closed loop control, safing, RIU digital filtering, and RIU stand alone testing with the CSI Evolutionary Model (CEM) Phase-0 testbed. The test results indicated that the CCS/RIU system is comparable to ground based systems in performing real-time control-structure experiments.

  6. TFTR tritium valve for pulsed gas feed, test results

    International Nuclear Information System (INIS)

    This paper presents the results of a test program currently being conducted at the PPPL (Princeton Plasma Physics Lab) to evaluate the design of an engineering-model valve to be used for controlling pulsed-feed tritium injection scenarios into the TFTR (TOKAMAK) torus. The test program is designed to characterize the performance of the valve and determine throughput modulation and repeatability. Testing is being performed primarily with helium gas, but the capability to test with argon, deuterium, and hydrogen gases is available in order to provide an adequate data base to extrapolate to the tritium case. The TFTR proposed tritium feed system line configurations have also been simulated to evaluate dynamic effects of the pulsed feed

  7. Orbiter post-tire failure and skid testing results

    Science.gov (United States)

    Daugherty, Robert H.; Stubbs, Sandy M.

    1989-01-01

    An investigation was conducted at the NASA Langley Research Center's Aircraft Landing Dynamics Facility (ALDF) to define the post-tire failure drag characteristics of the Space Shuttle Orbiter main tire and wheel assembly. Skid tests on various materials were also conducted to define their friction and wear rate characteristics under higher speed and bearing pressures than any previous tests. The skid tests were conducted to support a feasibility study of adding a skid to the orbiter strut between the main tires to protect an intact tire from failure due to overload should one of the tires fail. Roll-on-rim tests were conducted to define the ability of a standard and a modified orbiter main wheel to roll without a tire. Results of the investigation are combined into a generic model of strut drag versus time under failure conditions for inclusion into rollout simulators used to train the shuttle astronauts.

  8. Results from the 1999 Beam Test of a Preshower Prototype

    CERN Document Server

    Aspell, Paul; Bloch, Philippe; Bourotte, Jean; Domeniconi, Jacques; Peisert, Anna; Evangelou, Ioannis; Kloukinas, Kostas; Kyriakis, Aristotelis; Loos, Robert; Loukas, Demetrios; Mousa, Jehad; Peron, Franck; Reynaud, Serge; Sirunyan, Albert M; Tournefier, Edwige; Van Hove, Alain; Zamiatin, Nikolai

    2000-01-01

    At the end of June 1999 a test of a preshower prototype, equipped with real-size detectors and LHC-style electronics, was tested in the H4 beam at CERN in front of a matrix of "Endcap" crystals. Data were taken with a variety of incident electron energies, and three angles of incidence ( to simulate different regions of the CMS endcaps). The prototype functioned well, with a very small startup period and operated successfully for the duration of the test ( ~ 1 week) without intervention. Good agreement has been found between data and a GEANT-3 based simulation, and the absolute results are promising. Plans are presented for a further test of the prototype in 2000 in the H2 beam inside the 3T magnet.

  9. Testing Result Statistics-Based Rapid Testing Method for Safety-Critical System

    Institute of Scientific and Technical Information of China (English)

    Zhi-Yao Deng; Nan Sang

    2008-01-01

    Safety-critical system (SCS) has highlydemand for dependability, which requires plenty ofresource to ensure that the system under test (SUT)satisfies the dependability requirement. In this paper, anew SCS rapid testing method is proposed to improveSCS adaptive dependability testing. The result of each testexecution is saved in calculation memory unit andevaluated as an algorithm model. Then the least quantityof scenario test case for next test execution will becalculated according to the promised SUT's confidencelevel. The feedback data are generated to weightcontroller as the guideline for the further testing. Finally,a compre- hensive experiment study demonstrates thatthis adaptive testing method can really work in practice.This rapid testing method, testing result statistics-basedadaptive control, makes the SCS dependability testingmuch more effective.

  10. Suit Port Aft Bulkhead Mockup 2008 Test Results

    Science.gov (United States)

    Romig, Barbara A.; Allton, Charles S.; Litaker, Harry L.

    2009-01-01

    The Lunar Electric Rover (LER), formerly called the Small Pressurized Rover (SPR), is currently being carried as an integral part of the current Lunar Surface Architectures under consideration in the Constellation program. One element of the LER is the suit port, the means by which the crew performs Extravehicular Activities (EVAs). Two suit port deliverables were produced in fiscal year 2008: an aft bulkhead mockup for functional integrated testing with the 1-G LER mockup and a functional and pressurizable Engineering Unit (EU). This paper focuses on the aft bulkhead mockup test results from Desert Research and Technology Studies (D-RATS) October 2008 testing at Black Point Lava Flow (BPLF), Arizona. Refer to 39th International Conference on Environmental Systems (ICES) for test results of the EU. The suit port aft bulkhead mockup was integrated with the mockup of the LER cabin and chassis. It is located on the aft bulkhead of the LER cabin structure and includes hatches, a locking mechanism, seals, interior and exterior suit don/doff aids, and exterior platforms to accommodate different crewmember heights. A lightweight mockup of the Mark III suit was tested with the suit port aft bulkhead mockup. There are several limitations to the suit port and mockup suits, and results of the suit port evaluation are presented and interpreted within the context of the limitations.

  11. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2012-11-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  12. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  13. Uncertainty in Test Score Data and Classically Defined Reliability of Tests and Test Batteries, using a New Method for Test Dichotomisation

    OpenAIRE

    Chakrabartty, Satyendra Nath; Wang, Kangrui; Chakrabarty, Dalia

    2015-01-01

    As with all measurements, the measurement of examinee ability, in terms of scores that the examinee obtains in a test, is also error-ridden. The quantification of such error or uncertainty in the test score data--or rather the complementary test reliability--is pursued within the paradigm of Classical Test Theory in a variety of ways, with no existing method of finding reliability, isomorphic to the theoretical definition that parametrises reliability as the ratio of the true score variance a...

  14. SOFIA tracking subsystem: results of assembly, operation, and calibration tests

    Science.gov (United States)

    Bittner, Hermann; Erdmann, Matthias; Schmolke, Juergen; Lattner, Klaus; Levin, Torsten; Erhard, Markus

    2003-02-01

    The SOFIA airborne telescope has a Tracking Subsystem for stellar acquisition, tracking, and pointing. The system has three high-performance imagers: the boresighted wide field (6 degrees FOV) and fine field imagers (70 arcminutes FOV), and the main-telescope-optics sharing focal plane imager (8 arcminutes FOV). The imagers are controlled by 3 CCD head controllers, an overall imager controller, and a tracker controller providing the tracking error signals from the objects observed by the imagers. There have been several test steps in the assembly, integration, and verification of the Tracking Subsystem. The paper presents the fully integrated system as actually built, the results of the thermal-vacuum and vibration tests of the fine field imager, the tested operational/functional S/W performance, as well as the results of the geometric and radiometric calibrations of the imagers.

  15. DNB test results for new mixing vane grids

    International Nuclear Information System (INIS)

    As part of the continuing experimental program to investigate Departure from Nucleate Boiling (DNB) in rod bundles a series of tests using a new mixing vane grid design have been performed. This new grid has a reinforced type structure and is designated the ''R'' grid. Effects on DNB due to non-uniform axial heat flux distribution, heater rod length, and axial grid spacing were investigated. The test configuration simulated reactor ''typical'' coolant channels, i.e., surrounded by heated rods. With the results of this series of DNB tests (197 data points) a modified spacer factor was developed for application to the new R grid fuel rod bundles. This spacer factor is applied as a multiplet on the W-3 prediction of DNB heat flux. Use of this spacer factor as a multiplier on the W-3 correlation results in conservative prediction of DNB heat flux compared to the data. (auth)

  16. Guidelines to Interpret Results of Mechanical Blade Test

    International Nuclear Information System (INIS)

    This report shows the interpretation of full scale rotor blade test results and describes the engineering testing models and coefficients for any feasible rotor blade design, in order to accept and to certify any final manufactured blade as an allowable product, fit for use and working with a completely security during all the wind turbines lifetime. This work was carried out at the Wind Energy Division of the CIEMAT.DER and it is based on the authors technical experience in this field, after many years working on testing blades. Also, this paper contains results of the European wind turbine Standards II relevant to the European Project: JOULE III R.D. where the Wind Energy Division took part as participant too. (Author)

  17. GICHD Mine Dog Testing Project - Soil Sample Results No.3

    Energy Technology Data Exchange (ETDEWEB)

    PHELAN, JAMES M.; BARNETT, JAMES L.; BENDER, SUSAN FAE ANN; ARCHULETA, LUISA M.

    2003-03-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonal weather conditions. This report documents the analytical chemical methods and results from the third batch of soils received. This batch contained samples from Kharga, Afghanistan collected in October 2002.

  18. GICHD mine dog testing project : soil sample results #5.

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.; Donovan, Kelly L.; Bender, Susan Fae Ann

    2004-01-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonal weather conditions. This report documents the analytical chemical methods and results from the fifth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in June 2003.

  19. GICHD mine dog testing project - soil sample results #4.

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.; Wood, Tyson B.; Donovan, Kelly L.; Bender, Susan Fae Ann

    2003-08-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonal weather conditions. This report documents the analytical chemical methods and results from the fourth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in April 2003 and Sarajevo, Bosnia collected in May 2003.

  20. Profiling of drugs and environmental chemicals for functional impairment of neural crest migration in a novel stem cell-based test battery

    OpenAIRE

    Zimmer, Bastian; Pallocca, Giorgia; Dreser, Nadine; Foerster, Sunniva; Waldmann, Tanja; Westerhout, Joost; Julien, Sylvie; Krause, Karl-Heinz; van Thriel, Christoph; Hengstler, Jan G.; Sachinidis, Agapios; Bosgra, Sieto; Leist, Marcel

    2014-01-01

    Developmental toxicity in vitro assays have hitherto been established as stand-alone systems, based on a limited number of toxicants. Within the embryonic stem cell-based novel alternative tests project, we developed a test battery framework that allows inclusion of any developmental toxicity assay and that explores the responses of such test systems to a wide range of drug-like compounds. We selected 28 compounds, including several biologics (e.g., erythropoietin), classical pharmaceuticals ...

  1. Lifetime modelling of lead acid batteries

    Energy Technology Data Exchange (ETDEWEB)

    Bindner, H.; Cronin, T.; Lundsager, P.

    2005-04-01

    The performance and lifetime of energy storage in batteries are an important part of many renewable based energy systems. Not only do batteries impact on the system performance but they are also a significant expenditure when considering the whole life cycle costs. Poor prediction of lifetime can, therefore, lead to uncertainty in the viability of the system in the long term. This report details the work undertaken to investigate and develop two different battery life prediction methodologies with specific reference to their use in hybrid renewable energy systems. Alongside this, results from battery tests designed to exercise batteries in similar modes to those that they experience in hybrid systems have also been analysed. These have yielded battery specific parameters for use in the prediction software and the first results in the validation process of the software are also given. This work has been part of the European Union Benchmarking research project (ENK6-CT-2001-80576), funded by the European Union, the United States and Australian governments together with other European states and other public and private financing bodies. The project has concentrated on lead acid batteries as this technology is the most commonly used. Through this work the project partner institutions have intended to provide useful tools to improve the design capabilities of organizations, private and public, in remote power systems. (au)

  2. SSPS results of test and operation, 1981-1984

    Energy Technology Data Exchange (ETDEWEB)

    None

    1985-05-01

    The results of three years of testing and operation of the two dissimilar solar thermal power plants of the SSPS project are summarized. The project includes: (1) a Distributed Collector System, and (2) a Central Receiver System. Environmental conditions are presented and an economical assessment of the project is provided. (BCS)

  3. Recent results on the RIA test in IGR reactor

    Energy Technology Data Exchange (ETDEWEB)

    Asmolov, V.; Yegorova, L. [Nuclear Safety Institute, Moscow (Russian Federation)

    1997-01-01

    At the 23d WRSM meeting the data base characterizing results of VVER high burnup fuel rods tests under reactivity-initiated accident (RIA) conditions was presented. Comparison of PWR and VVER failure thresholds was given also. Additional analysis of the obtained results was being carried out during 1996. The results of analysis show that the two different failure mechanisms were observed for PWR and VVER fuel rods. Some factors which can be as the possible reasons of these differences are presented. First of them is the state of preirradiated cladding. Published test data for PWR high burnup fuel rods demonstrated that the PWR high burnup fuel rods failed at the RIA test are characterized by very high level of oxidation and hydriding for the claddings. Corresponding researches were performed at Institute of Atomic Reactors (RLAR, Dimitrovgrad, Russia) for large set of VVER high burnup fuel rods. Results of these investigations show that preirradiated commercial Zr-1%Nb claddings practically keep their initial levels of oxidation and H{sub 2} concentration. Consequently the VVER preirradiated cladding must keep the high level of mechanical properties. The second reason leading to differences between failure mechanisms for two types of high burnup fuel rods can be the test conditions. Now such kind of analysis have been performed by two methods.

  4. Severe fuel damage scoping test postirradiation examination results

    International Nuclear Information System (INIS)

    The fuel bundle from the Severe Fuel Damage Scoping Test, conducted in the Power Burst Facility as part of the international Severe Fuel Damage Research Program, was examined posttest. This paper presents the results of the nondestructive portion of the examination, including gross gamma scanning, neutron radiography, and tomographic reconstruction of cross sections through the bundle using the neutron radiographs

  5. Large-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Bontha, Jagannadha R.; Daniel, Richard C.; Kurath, Dean E.; Adkins, Harold E.; Billing, Justin M.; Burns, Carolyn A.; Davis, James M.; Enderlin, Carl W.; Fischer, Christopher M.; Jenks, Jeromy WJ; Lukins, Craig D.; MacFarlan, Paul J.; Shutthanandan, Janani I.; Smith, Dennese M.

    2012-12-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  6. The Relationship between the Luria-Nebraska Neuropsychological Battery-Children's Revision and The Minnesota Percepto-Diagnostic Test With Learning Disabled Students.

    Science.gov (United States)

    Snow, Jeffrey H.; And Others

    1983-01-01

    Administered the Luria-Nebraska Neuropsychological Battery-Children's Revision (LNNB-Children's Revision) and The Minnesota Percepto-Diagnostic Test (MPD) to 40 learning disabled students. Low correlations were found between MPD T scores and the LNNB-Children's Revision Scales, but raw scores from the MPD had somewhat higher correlations with the…

  7. Graphite electrode arc melter demonstration Phase 2 test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; O`Connor, W.K.; Oden, L.L.; Turner, P.C.

    1996-06-01

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau`s Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of {open_quotes}as-received{close_quotes} heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process.

  8. A proposal regarding reporting of in vitro testing results.

    Science.gov (United States)

    Smith, Malcolm A; Houghton, Peter

    2013-06-01

    The high rate of negative clinical trials and failed drug development programs calls into question the use of preclinical testing as currently practiced. An important issue for the in vitro testing of agents that have advanced into the clinic is the use of clinically irrelevant concentrations in reports making claims for anticancer activity, as illustrated by publications for sorafenib, vorinostat, and metformin. For sorafenib, high protein binding leads to a dichotomy between concentrations active in the 10% serum conditions commonly used for in vitro testing and concentrations active in plasma. Failure to recognize this distinction leads to inappropriate claims of activity for sorafenib based on the micromolar concentrations commonly used for in vitro testing in low serum conditions. For vorinostat and metformin, results using in vitro concentrations higher than those achievable in patients are reported despite the availability of publications describing human pharmacokinetic data for each agent. We encourage journal editors and reviewers to pay greater attention to clinically relevant concentrations when considering reports that include in vitro testing of agents for which human pharmacokinetic data are available. Steps taken to more carefully scrutinize activity claims based on in vitro results can help direct researchers away from clinically irrelevant lines of research and toward lines of research that are more likely to lead to positive clinical trials and to improved treatments for patients with cancer. PMID:23580781

  9. Graphite electrode arc melter demonstration Phase 2 test results

    International Nuclear Information System (INIS)

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau's Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of open-quotes as-receivedclose quotes heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process

  10. Updated test results of a pumped monopropellant propulsion system

    Science.gov (United States)

    Maybee, Jeffrey C.; Swink, Don G.; Whitehead, John C.

    1993-11-01

    Significant progress was made in 1992 and 1993 towards demonstration at the system level of a high-performance pumped monopropellant propulsion system. Two separate breadboard systems were designed, fabricated and tested with hydrazine at vacuum and sea level conditions. Both designs utilized improved warm-gas-driven reciprocating pumps to transfer fuel from a low-pressure hydrazine tank (70 psig) directly to a pair of 56-lbf thrusters operating at 580 psia chamber pressure. The system most recently tested included direct warm gas pressurization of the hydrazine tank. This novel propulsion system design has been presented and discussed in various configurations in previous papers. This paper will provide an update to test results presented in 1991. This recent testing of these latest system designs included a continuous 60-second burn of a 42-lbf thruster operating at sea level, in addition bootstrap and pulse-mode firings. These results have demonstrated that improvements to the 3-way valve design of the pump were successful, and have verified performance predictions obtained from a mathematical model of the system. Further testing of a more advanced breadboard system is planned for late 1993.

  11. A novel automated behavioral test battery assessing cognitive rigidity in two genetic mouse models of autism.

    Directory of Open Access Journals (Sweden)

    Alicja ePuścian

    2014-04-01

    Full Text Available Repetitive behaviors are a key feature of many pervasive developmental disorders, such as autism. As a heterogeneous group of symptoms, repetitive behaviors are conceptualized into two main subgroups: sensory/motor (lower-order and cognitive rigidity (higher-order. Although lower-order repetitive behaviors are measured in mouse models in several paradigms, so far there have been no high-throughput tests directly measuring cognitive rigidity. We describe a novel approach for monitoring repetitive behaviors during reversal learning in mice in the automated IntelliCage system. During the reward-motivated place preference reversal learning, designed to assess cognitive abilities of mice, visits to the previously rewarded places were recorded to measure cognitive flexibility. Thereafter, emotional flexibility was assessed by measuring conditioned fear extinction. Additionally, to look for neuronal correlates of cognitive impairments, we measured CA3-CA1 hippocampal long term potentiation (LTP. To standardize the designed tests we used C57BL/6 and BALB/c mice, representing two genetic backgrounds, for induction of autism by prenatal exposure to the sodium valproate. We found impairments of place learning related to perseveration and no LTP impairments in C57BL/6 valproate-treated mice. In contrast, BALB/c valproate-treated mice displayed severe deficits of place learning not associated with perseverative behaviors and accompanied by hippocampal LTP impairments. Alterations of cognitive flexibility observed in C57BL/6 valproate-treated mice were related to neither restricted exploration pattern nor to emotional flexibility. Altogether, we showed that the designed tests of cognitive performance and perseverative behaviors are efficient and highly replicable. Moreover, the results suggest that genetic background is crucial for the behavioral effects of prenatal valproate treatment.

  12. Severe Fuel Damage Test 1-1 results

    International Nuclear Information System (INIS)

    A series of severe fuel damage tests is being performed in the Power Burst Facility to obtain data necessary to understand (a) fuel behavior and coolability; (b) fission product release, deposition, and transport; and (c) hydrogen release during degraded core cooling accidents. This report presents the preliminary results of the second experiment of the Severe Fuel Damage (SFD) series, Test SFD 1-1. The measurements indicate that the test conditions required to simulate the fuel damage and fission produce release in a 3000-MW(t) commercial pressurized water reactor core during a small break loss-of-coolant accident without emergency core coolant injection were successfully achieved. Such an accident is characterized by an initial slow heating rate to about 16000K, followed by a very rapid heating rate driven by runaway metal-water reaction that is steam limited in the upper regions of the core. The fast heatup achieved during the SFD 1-1 test resulted in oxidation of about 30% of the cladding and shroud inner liner and melting of much of the cladding in the lower regions of the fuel bundle. Significant liquefaction of the UO2 fuel occurred and molten cladding and liquefied fuel slumped to lower bundle elevations. The fission product release during this test was less than during the first experiment of the series (the Scoping Test, which was performed at relatively high steam flow rates), during which nearly all of the cladding was oxidized. Iodine and cesium followed the liquid pathway, and most of the tellurium remained within the test bundle

  13. Results of MACE tests M0 and M1

    International Nuclear Information System (INIS)

    This document discusses the Melt Attack and Coolability Experiment (MACE) Program underway at Argonne National Laboratory under ACE/EPRI sponsorship. The program addresses the efficacy of water to terminate an accident situation if melt progression were to result in a molten core/concrete interaction (MCCI) in the reactor containment. Large-scale experiments are being conducted in parallel with related modeling efforts, involving the addition of water to an MCI already underway. The experiments utilize UO2/ZrO2/Zr corium mixtures, direct electrical heating for simulation of decay heating, and various types of concrete basemats. Currently the tests involve 430 kg corium mass, 25 cm depth, in a 50 cm square test section. Test MO was a successful scoping test, but the first full size test, Ml, failed to achieve melt-water contact owing to existence of a preexisting bridge crust of corium charge. A heat flux of 3.5 MW/m2 was measured in MO which removed energy from the corium pool equivalent to its entire heat of solidification prior to abatement by formation of an interfacial crust. The crust subsequently limited heat extraction to 600 kW/m2 and less. Both tests MO and Ml revealed physical evidence of large pool swelling events which resulted in extrusion (and ejection) of melt into water above the crust, significantly increasing the overall quench and reducing the remaining melt in contact with the concrete. Furthermore, test Ml provided evidence of occasional ''burst mode'' ablation events and one additional important benefit of overlying water -- aerosol capture

  14. Results of MACE tests M0 and M1

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, B.W.; Farmer, M.T.; Armstrong, D.R.; Kilsdonk, D.J.; Aeschlimann, R.W. [Argonne National Lab., IL (United States); Fischer, M. [Siemens AG, Berlin (Germany)

    1992-04-01

    This document discusses the Melt Attack and Coolability Experiment (MACE) Program underway at Argonne National Laboratory under ACE/EPRI sponsorship. The program addresses the efficacy of water to terminate an accident situation if melt progression were to result in a molten core/concrete interaction (MCCI) in the reactor containment. Large-scale experiments are being conducted in parallel with related modeling efforts, involving the addition of water to an MCI already underway. The experiments utilize UO{sub 2}/ZrO{sub 2}/Zr corium mixtures, direct electrical heating for simulation of decay heating, and various types of concrete basemats. Currently the tests involve 430 kg corium mass, 25 cm depth, in a 50 cm square test section. Test MO was a successful scoping test, but the first full size test, Ml, failed to achieve melt-water contact owing to existence of a preexisting bridge crust of corium charge. A heat flux of 3.5 MW/m{sup 2} was measured in MO which removed energy from the corium pool equivalent to its entire heat of solidification prior to abatement by formation of an interfacial crust. The crust subsequently limited heat extraction to 600 kW/m{sup 2} and less. Both tests MO and Ml revealed physical evidence of large pool swelling events which resulted in extrusion (and ejection) of melt into water above the crust, significantly increasing the overall quench and reducing the remaining melt in contact with the concrete. Furthermore, test Ml provided evidence of occasional ``burst mode`` ablation events and one additional important benefit of overlying water -- aerosol capture.

  15. Results of MACE tests M0 and M1

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, B.W.; Farmer, M.T.; Armstrong, D.R.; Kilsdonk, D.J.; Aeschlimann, R.W. (Argonne National Lab., IL (United States)); Fischer, M. (Siemens AG, Berlin (Germany))

    1992-01-01

    This document discusses the Melt Attack and Coolability Experiment (MACE) Program underway at Argonne National Laboratory under ACE/EPRI sponsorship. The program addresses the efficacy of water to terminate an accident situation if melt progression were to result in a molten core/concrete interaction (MCCI) in the reactor containment. Large-scale experiments are being conducted in parallel with related modeling efforts, involving the addition of water to an MCI already underway. The experiments utilize UO{sub 2}/ZrO{sub 2}/Zr corium mixtures, direct electrical heating for simulation of decay heating, and various types of concrete basemats. Currently the tests involve 430 kg corium mass, 25 cm depth, in a 50 cm square test section. Test MO was a successful scoping test, but the first full size test, Ml, failed to achieve melt-water contact owing to existence of a preexisting bridge crust of corium charge. A heat flux of 3.5 MW/m{sup 2} was measured in MO which removed energy from the corium pool equivalent to its entire heat of solidification prior to abatement by formation of an interfacial crust. The crust subsequently limited heat extraction to 600 kW/m{sup 2} and less. Both tests MO and Ml revealed physical evidence of large pool swelling events which resulted in extrusion (and ejection) of melt into water above the crust, significantly increasing the overall quench and reducing the remaining melt in contact with the concrete. Furthermore, test Ml provided evidence of occasional burst mode'' ablation events and one additional important benefit of overlying water -- aerosol capture.

  16. Long Term Corrosion/Degradation Test Six Year Results

    Energy Technology Data Exchange (ETDEWEB)

    M. K. Adler Flitton; C. W. Bishop; M. E. Delwiche; T. S. Yoder

    2004-09-01

    The Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) contains neutron-activated metals from non-fuel, nuclear reactor core components. The Long-Term Corrosion/Degradation (LTCD) Test is designed to obtain site-specific corrosion rates to support efforts to more accurately estimate the transfer of activated elements to the environment. The test is using two proven, industry-standard methods—direct corrosion testing using metal coupons, and monitored corrosion testing using electrical/resistance probes—to determine corrosion rates for various metal alloys generally representing the metals of interest buried at the SDA, including Type 304L stainless steel, Type 316L stainless steel, Inconel 718, Beryllium S200F, Aluminum 6061, Zircaloy-4, low-carbon steel, and Ferralium 255. In the direct testing, metal coupons are retrieved for corrosion evaluation after having been buried in SDA backfill soil and exposed to natural SDA environmental conditions for times ranging from one year to as many as 32 years, depending on research needs and funding availability. In the monitored testing, electrical/resistance probes buried in SDA backfill soil will provide corrosion data for the duration of the test or until the probes fail. This report provides an update describing the current status of the test and documents results to date. Data from the one-year and three-year results are also included, for comparison and evaluation of trends. In the six-year results, most metals being tested showed extremely low measurable rates of general corrosion. For Type 304L stainless steel, Type 316L stainless steel, Inconel 718, and Ferralium 255, corrosion rates fell in the range of “no reportable” to 0.0002 mils per year (MPY). Corrosion rates for Zircaloy-4 ranged from no measurable corrosion to 0.0001 MPY. These rates are two orders of magnitude lower than those specified in

  17. Pipe rupture test results; 4 inch pipe whip test under BWR LOCA conditions

    International Nuclear Information System (INIS)

    Pipe whip tests or jet discharge tests have been performed in JAERI, which simulate the instantaneous circumferential guillotine break of primary coolant piping in nuclear power plants. This report summarizes the results of 4 inch pipe whip tests (RUN 5407, 5501, 5504, 5603), under BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 2850C. In these tests clearance was kept constant at the value of 100 mm and overhang length were 250 mm, 400 mm, 550 mm and 1000 mm, respectively. The main purpose of these tests was to investigate the effect of overhang length on pipe whip behavior. From the tests results, a shorter overhang length is recommended to minimize the deformation of the pipe and restraints. (author)

  18. A terracotta bio-battery.

    Science.gov (United States)

    Ajayi, Folusho F; Weigele, Peter R

    2012-07-01

    Terracotta pots were converted into simple, single chamber, air-cathode bio-batteries. This bio-battery design used a graphite-felt anode and a conductive graphite coating without added catalyst on the exterior as a cathode. Bacteria enriched from river sediment served as the anode catalyst. These batteries gave an average OCV of 0.56 V ± 0.02, a Coulombic efficiency of 21 ± 5%, and a peak power of 1.06 mW ± 0.01(33.13 mW/m(2)). Stable current was also produced when the batteries were operated with hay extract in salt solution. The bacterial community on the anode of the batteries was tested for air tolerance and desiccation resistance over a period ranging from 2 days to 2 weeks. The results showed that the anode community could survive complete drying of the electrolyte for several days. These data support the further development of this technology as a potential power source for LED-based lighting in off-grid, rural communities. PMID:22609660

  19. Test Results of the ALICE-HMPID Detector Commissioning

    CERN Document Server

    Volpe, G

    2008-01-01

    The ALICE High Momentum Particle Identification Detector (HMPID) consists of seven identical proximity focusing RICH counters. It covers in total 11 m2, exploiting large area CsI photocathodes for Cherenkov light imaging. The detector is installed in the ALICE solenoid, ready for the data acquisition. By means of the Detector Control System, the Front-end (FEE) and the Readout (R/O) electronics, the MWPC high voltages, the cooling and the gas system have been tested. The HMPID module gas pressure, temperature, current and voltage trends have been monitored and archived in the ORACLE database. In this paper a comprehensive review on the test results is presented.

  20. PISA TESTS IN LATIN AMERICA: RESULTS IN CONTEXT

    Directory of Open Access Journals (Sweden)

    Guillermina Tiramonti

    2014-05-01

    Full Text Available The educational reforms implemented in Latin America in the ‘90s introduced changes in the modes of regulation of educational systems based on the adoption of mechanisms for assessing student achievement. Since 2000, eight Latin-American countries (Argentina, Chile, Uruguay, Colombia, Brazil, Costa Rica, Mexico and Peru are involved in the PISA tests. The article presents a brief review of the social and educational situation of the Region, relevant for the interpretation and comparative analysis of the results of these tests that is presented below.

  1. Depressurisation studies. Phase 3: results of Tests 142 and 143

    International Nuclear Information System (INIS)

    A basic experimental programme involving the sudden depressurisation of a simple pipe system containing water at 3.45 to 17.24MPa pressure and temperatures between 220 and 2500C has been concluded. Measurements were made of transient density, pressure, and temperature variations in a two-phase fluid in the system during the discharge. Phase 3 tests, which are reported, examined the blowdown of a straight 206m dia pipe, 4m long, with particular emphasis on the transient void distribution across a section of the pipe. The results of two tests are detailed. (UK)

  2. Test beam results of the ATLAS electromagnetic calorimeter prototype modules

    CERN Document Server

    Maslennikov, A L

    2002-01-01

    The pre-series modules of the future ATLAS liquid argon electromagnetic calorimeter (the LHC project) have been tested in 1999-2000 with electron beams at CERN SPS. Detailed results of these tests are presented, including the performance of ATLAS-like electronics. Energy resolution of better than 9.5%/ root E (barrel) and 10.5-12.5%/ root E (end-cap) is obtained. Angular resolution measured ( asymptotically equal to 50 mrad/ root E, end-cap) also fits to physics requirements.

  3. The Results of Tests of the MICE Spectrometer Solenoids

    International Nuclear Information System (INIS)

    The Muon Ionization Cooling Experiment (MICE) spectrometer solenoid magnets will be the first magnets to be installed within the MICE cooling channel. The spectrometer magnets are the largest magnets in both mass and surface area within the MICE ooling channel. Like all of the other magnets in MICE, the spectrometer solenoids are kept cold using 1.5 W (at 4.2 K) pulse tube coolers. The MICE spectrometer solenoid is quite possibly the largest magnet that has been cooled using small coolers. Two pectrometer magnets have been built and tested. This report discusses the results of current and cooler tests of both magnets.

  4. Patch Test Results of 775 Patients with Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Simin Ada

    2010-12-01

    Full Text Available Background and Design: The allergens responsible for allergic contact dermatitis vary among countries and even between different geographical regions within the same country over time. It is of great importance to perform the patch test at certain intervals, to evaluate the results in different centers and to compare them afterwards. Our aim was to evaluate the patch test results in our patients with allergic contact dermatitis.Material and Method: The records of the patients with allergic contact dermatitis, who had been patch tested between May 1997 and March 2009, were analyzed retrospectively. The demographic features such as age and sex, localization of the contact dermatitis, and the patch test results were recorded. Results: Of the 775 patients, 581 (75.2% were females and 194 (25% males. Of all patients, 735 were patch tested with the European Standard Series, 318 - with both the European Standard Series and cosmetic series, and 40-with cosmetic series alone. Of the patients tested with the European Standard Series, 255 (34.7% had at least one positive reaction. The most frequent allergen in the European Standard Series was nickel sulfate (17.3%, followed by cobalt chloride (7.2%, potassium dichromate (3%, fragrance mix (2.9%, and p-phenylenediamine base (2.6%. Of the 358 patients tested with cosmetic series, 82 (22.9% had at least one positive reaction. The 5 most frequently observed cosmetic series allergens were octyl gallate (3.9%, thimerosal (2.2%, sorbitan sesquioleate (2%, Euxyl K 400 (2% and methyldibromo glutaronitrile (1.4%. Conclusion: Our study shows the contact allergen profile of our center over 12 years. The most common allergens and their frequency differ between centers in various cities in Turkey. Those geographical differences should be re-evaluated by further studies performed in the certain time period. The high frequency of reactions to octyl gallate is an important finding in patients suspected of cosmetic allergy

  5. Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing

    Science.gov (United States)

    Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.

    1990-01-01

    During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.

  6. Capillary Suction Time (CST) Test: Developments in testing methodology and reliability of results

    OpenAIRE

    Sawalha, Ola

    2011-01-01

    The dewatering of wastewater sludge (slurry) is a routine operation at wastewater treatment plants, and the results of dewaterability tests underpin the selection of dewatering processes. The two most commonly applied dewaterability tests for this purpose are the capillary suction time (CST) test and the specific resistance to filtration (SRF) test. The aim of this research was to develop improved methods of estimating sludge dewaterability by modifying the components and pr...

  7. Interim Guidance for Interpretation of Zika Virus Antibody Test Results.

    Science.gov (United States)

    Rabe, Ingrid B; Staples, J Erin; Villanueva, Julie; Hummel, Kimberly B; Johnson, Jeffrey A; Rose, Laura; Hills, Susan; Wasley, Annemarie; Fischer, Marc; Powers, Ann M

    2016-01-01

    Zika virus is a single-stranded RNA virus in the genus Flavivirus and is closely related to dengue, West Nile, Japanese encephalitis, and yellow fever viruses (1,2). Among flaviviruses, Zika and dengue virus share similar symptoms of infection, transmission cycles, and geographic distribution. Diagnostic testing for Zika virus infection can be accomplished using both molecular and serologic methods. For persons with suspected Zika virus disease, a positive real-time reverse transcription-polymerase chain reaction (rRT-PCR) result confirms Zika virus infection, but a negative rRT-PCR result does not exclude infection (3-7). In these cases, immunoglobulin (Ig) M and neutralizing antibody testing can identify additional recent Zika virus infections (6,7). However, Zika virus antibody test results can be difficult to interpret because of cross-reactivity with other flaviviruses, which can preclude identification of the specific infecting virus, especially when the person previously was infected with or vaccinated against a related flavivirus (8). This is important because the results of Zika and dengue virus testing will guide clinical management. Pregnant women with laboratory evidence of Zika virus infection should be evaluated and managed for possible adverse pregnancy outcomes and be reported to the U.S. Zika Pregnancy Registry or the Puerto Rico Zika Active Pregnancy Surveillance System for clinical follow-up (9,10). All patients with clinically suspected dengue should have proper management to reduce the risk for hemorrhage and shock (11). If serologic testing indicates recent flavivirus infection that could be caused by either Zika or dengue virus, patients should be clinically managed for both infections because they might have been infected with either virus. PMID:27254248

  8. Battery Modeling

    OpenAIRE

    Jongerden, M.R.; Haverkort, B.R.

    2008-01-01

    The use of mobile devices is often limited by the capacity of the employed batteries. The battery lifetime determines how long one can use a device. Battery modeling can help to predict, and possibly extend this lifetime. Many different battery models have been developed over the years. However, with these models one can only compute lifetimes for specific discharge profiles, and not for workloads in general. In this paper, we give an overview of the different battery models that are availabl...

  9. Results of the quality assurance testing program for radiopharmaceuticals 1995

    Energy Technology Data Exchange (ETDEWEB)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( {sup 99m}Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [{sup 201}Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs.

  10. Results of the quality assurance testing program for radiopharmaceuticals 1995

    International Nuclear Information System (INIS)

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( 99mTc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [201Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs

  11. Planar pixel sensors for the ATLAS upgrade: beam tests results

    International Nuclear Information System (INIS)

    The performance of planar silicon pixel sensors, in development for the ATLAS Insertable B-Layer and High Luminosity LHC (HL-LHC) upgrades, has been examined in a series of beam tests at the CERN SPS facilities since 2009. Salient results are reported on the key parameters, including the spatial resolution, the charge collection and the charge sharing between adjacent cells, for different bulk materials and sensor geometries. Measurements are presented for n+-in-n pixel sensors irradiated with a range of fluences and for p-type silicon sensors with various layouts from different vendors. All tested sensors were connected via bump-bonding to the ATLAS Pixel read-out chip. The tests reveal that both n-type and p-type planar sensors are able to collect significant charge even after the lifetime fluence expected at the HL-LHC.

  12. TEST RESULTS FOR LHC INSERTION REGION DEPOLE MAGNETS

    International Nuclear Information System (INIS)

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They are required to produce fields up to 4.14 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, whose construction was very different from the RHIC dipoles, except for the coil design. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality

  13. Cycom 977-2 Composite Material: Impact Test Results

    Science.gov (United States)

    Engel, Carl D.; Herald, Stephen; Watkins, Casey

    2005-01-01

    The reaction frequency data from 13A testing by MSFC and WSTF appear well behaved for the sample number used by each and exhibit the same type of energy level dependency. The reaction frequency shift in energy level is unexplained at this time. All the 13A data suggest that only a small amount of material is consumed when reactions take place. At ambient pressure, most of not all reactions are quenched as indicated by the small mass loss. As test pressure is increased in LOX using 13B results. Cycom does not support initiation of reactions or propagations of reactions in GOX at 100 psis based on tests at MSFC and WSTF at 72 ft-lb impact energy. No batch effect was identified in LOX or GOX.

  14. Dipole model test with one superconducting coil: results analysed

    CERN Document Server

    Bajas, H; Benda, V; Berriaud, C; Bajko, M; Bottura, L; Caspi, S; Charrondiere, M; Clément, S; Datskov, V; Devaux, M; Durante, M; Fazilleau, P; Ferracin, P; Fessia, P; Gauthier, R; Giloux, C; Guinchard, M; Kircher, F; Manil, P; Milanese, A; Millot, J-F; Muñoz Garcia, J-E; Oberli, L; Perez, J-C; Pietrowicz, S; Rifflet, J-M; de Rijk, G; Rondeaux, F; Todesco, E; Viret, P; Ziemianski, D

    2013-01-01

    This report is the deliverable report 7.3.1 “Dipole model test with one superconducting coil; results analysed “. The report has four parts: “Design report for the dipole magnet”, “Dipole magnet structure tested in LN2”, “Nb3Sn strand procured for one dipole magnet” and “One test double pancake copper coil made”. The 4 report parts show that, although the magnet construction will be only completed by end 2014, all elements are present for a successful completion. Due to the importance of the project for the future of the participants and given the significant investments done by the participants, there is a full commitment to finish the project.

  15. Dipole model test with one superconducting coil; results analysed

    CERN Document Server

    Durante, M; Ferracin, P; Fessia, P; Gauthier, R; Giloux, C; Guinchard, M; Kircher, F; Manil, P; Milanese, A; Millot, J-F; Muñoz Garcia, J-E; Oberli, L; Perez, J-C; Pietrowicz, S; Rifflet, J-M; de Rijk, G; Rondeaux, F; Todesco, E; Viret, P; Ziemianski, D

    2013-01-01

    This report is the deliverable report 7.3.1 “Dipole model test with one superconducting coil; results analysed “. The report has four parts: “Design report for the dipole magnet”, “Dipole magnet structure tested in LN2”, “Nb3Sn strand procured for one dipole magnet” and “One test double pancake copper coil made”. The 4 report parts show that, although the magnet construction will be only completed by end 2014, all elements are present for a successful completion. Due to the importance of the project for the future of the participants and given the significant investments done by the participants, there is a full commitment to finish the project.

  16. High-Speed, High-Temperature Finger Seal Test Results

    Science.gov (United States)

    Proctor, Margaret P.; Kumar, Arun; Delgado, Irebert R.

    2002-01-01

    Finger seals have significantly lower leakage rates than conventional labyrinth seals used in gas turbine engines and are expected to decrease specific fuel consumption by over 1 percent and to decrease direct operating cost by over 0.5 percent. Their compliant design accommodates shaft growth and motion due to thermal and dynamic loads with minimal wear. The cost to fabricate these finger seals is estimated to be about half the cost to fabricate brush seals. A finger seal has been tested in NASA's High Temperature, High Speed Turbine Seal Test Rig at operating conditions up to 1200 F, 1200 ft/s, and 75 psid. Static, performance and endurance test results are presented. While seal leakage and wear performance are acceptable, further design improvements are needed to reduce the seal power loss.

  17. The JET ICRF antennae systems: Description and test bed results

    International Nuclear Information System (INIS)

    The main design features and test results of the prototype antennae systems for ICRF heating of JET are described. These have integral side protection, thick tilted screens, monopole or quadrupole central conductors, and are each fed by two co-axial lines of diameter varying from 100 to 230mm. The vacuum window is of a double, vacuum brazed alumina construction. The main components have been tested on the JET RF Test Bed at Fontenay-aux-Roses to maximum voltage (50kV) and current (1500 Amps). Apart from a narrow forbidden band at a low voltage due to the onset of multipactor arcs, these systems have largely met the required specifications

  18. Small-Scale Spray Releases: Orifice Plugging Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Blanchard, Jeremy; Kimura, Marcia L.; Kurath, Dean E.

    2012-09-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities, is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations published in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials present in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty introduced by extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches in which the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are largely absent. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine the aerosol release fractions and aerosol generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents (AFA) was assessed with most of the simulants. Orifices

  19. Severe fuel damage test 1-1 results

    International Nuclear Information System (INIS)

    A series of severe fuel damage tests is being performed in the Power Burst Facility to obtain data necessary to understand (a) fuel behavior and coolability; (b) fission product release, deposition, and transport; and (e) hydrogen release during degraded core cooling accidents. This report presents the preliminary results of the second experiment of the Severe Fuel Damage (SFD) series. The measurements indicate that the test conditions required to simulate the fuel damage and fission produce release in a 3000-MW(t) commercial PWR core during a small break loss-of-coolant accident without emergency core coolant injection were successfully achieved. Such an accident is characterized by an initial slow heating rate to about 1600 K, followed by a very rapid heating rate driven by runaway metal-water reaction that is steam limited in the upper regions of the core. The fast heatup achieved during the SFD 1-1 test resulted in oxidation of about 30% of the cladding and shroud inner liner and melting of much of the cladding in the lower regions of the fuel bundle. Significant liquefaction of the UO2 fuel occured and molten cladding and liquefied fuel slumped to lower bundle elevations. The fission product release during this test was less than during the first experiment of the series (the Scoping Test, which was performed at relatively high steam flow rates), during which nearly all of the cladding was oxidized. Iodine and cesium followed the liquid pathway, and most of the tellurium remained within the test bundle. (orig./HP)

  20. Test Results for a High Power Thermal Management System

    Science.gov (United States)

    Wrenn, Kimberly R.; Wolf, David A.

    2008-01-01

    In response to the identified needs of emerging high power spacecraft applications, a multiple evaporator hybrid loop heat pipe (H-LHP) was developed and tested as part of a Dual Use Science and Technology (DUS&T) program co-sponsored by ATK and AFRL/PRP. During the course of the DUS&T program, a two-kilowatt system with three evaporators was developed and tested to identify viable system architectures and characterize system performance capabilities as a function of heat load profiles and spatial distribution of the evaporators. Following the successful development of the two-kilowatt system, a 10-kilowatt system with six evaporators was fabricated and tested. Tests were performed with the system operating in a totally passive mode, where applying a small amount of power to a sweepage evaporator provides the auxiliary flow through the primary evaporators, and as a self-regulating, capillary-controlled mechanically pumped system. This paper will provide a description of the 10-kilowatt multi-evaporator system and present the results of the passive and mechanically pump test programs.

  1. Spent fuel drying system test results (second dry-run)

    International Nuclear Information System (INIS)

    The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks have been detected in the basins and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site (WHC 1995). Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL) on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of the second dry-run test, which was conducted without a fuel element. With the concurrence of project management, the test protocol for this run, and subsequent drying test runs, was modified. These modifications were made to allow for improved data correlation with drying procedures proposed under the IPS. Details of these modifications are discussed in Section 3.0

  2. Experimental Results of Integrated Refrigeration and Storage System Testing

    Science.gov (United States)

    Notardonato, W. U.; Johnson, W. L.; Jumper, K.

    2009-01-01

    Launch operations engineers at the Kennedy Space Center have identified an Integrated Refrigeration and Storage system as a promising technology to reduce launch costs and enable advanced cryogenic operations. This system uses a close cycle Brayton refrigerator to remove energy from the stored cryogenic propellant. This allows for the potential of a zero loss storage and transfer system, as well and control of the state of the propellant through densification or re-liquefaction. However, the behavior of the fluid in this type of system is different than typical cryogenic behavior, and there will be a learning curve associated with its use. A 400 liter research cryostat has been designed, fabricated and delivered to KSC to test the thermo fluid behavior of liquid oxygen as energy is removed from the cryogen by a simulated DC cycle cryocooler. Results of the initial testing phase focusing on heat exchanger characterization and zero loss storage operations using liquid oxygen are presented in this paper. Future plans for testing of oxygen densification tests and oxygen liquefaction tests will also be discussed. KEYWORDS: Liquid Oxygen, Refrigeration, Storage

  3. Large-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Gauglitz, Phillip A.; Burns, Carolyn A.; Fountain, Matthew S.; Shimskey, Rick W.; Billing, Justin M.; Bontha, Jagannadha R.; Kurath, Dean E.; Jenks, Jeromy WJ; MacFarlan, Paul J.; Mahoney, Lenna A.

    2013-08-01

    One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used

  4. The hadron calorimeter prototype beam-test results

    CERN Document Server

    Coca, C; Rosca, A; Ajinenko, I; Dorokhov, A E; Dzhelyadin, R I; Konoplyannikov, A K; Matveev, V; Novikov, V; Yushchenko, O P; Ranyuk, Y

    2000-01-01

    Here We present here the beam-test results obtained with the HCAL Prototype exposed on the X7 beam line of the CERN SPS accelerator. The iron plate: - scintillator tile sampling calorimeter has been tested in the bearn momenta range 10 = 80 GeV/c. The measured energy, angular and coordinate dependences of the HCAL responce and resolution were found to be corresponding to the LHCb design requirements. The angular and X-Y coordinate uniformity have been checked and compared with stand-alone Monte-Carlo simulation program predictions. The radioactive source calibration procedure has been developed. The LED pulse system allows to monitor the short-term stability of the detector. New 40 MHz front-end electronics have been tested and compared with ordinary charge integrating ADC's. The results of the first combined calorimeter tests are also presented. The signal shapes have been studied for FICA L., instrumented with different fiber types and were found to satisfy the I,IICb performance requirements.

  5. Horizontal grout barrier project results of the latest testing

    International Nuclear Information System (INIS)

    Throughout United States Department of Energy (DOE) sites are situations where storage tanks and pits are leaking or have the potential to leak contamination into the soil. Subsequent leaching from rain and groundwater flow disperses the contamination far from the original site and, in some cases, into aquifers which serve as a drinking water source. Fernald Environmental Restoration Management Corporation (FERMCO) at Fernald working with the DOE Office of Technology Development (OTD) and two subcontractors, is pursuing the goal of placing a barrier beneath the contamination to prevent this dispersion. The technology being developed is an in situ approach based on directional drilling and jet grouting techniques developed in the oil fields. The unique barrier techniques being developed depend on innovative tooling and special grouts to install a horizontal barrier underground without disturbing the contaminated soils above. The initial tool designs were tested in December 1992 and were encouraging enough that the DOE agreed to fund continued development. A second set of designs were tested in August 1994. The testing results were less than expected but did provide a number of lessons learned. This paper reports on the third set of tool designs and the results of testing these tools prior to the full demonstration project at Fernald

  6. Results of testing various natural gas desulfurization adsorbents

    Science.gov (United States)

    Israelson, Gordon

    2004-06-01

    This article presents the results of testing many commercially available and some experimental sulfur adsorbents. The desired result of our testing was to find an effective method to reduce the quantity of sulfur in natural gas to less than 100 ppb volume (0.1 ppm volume). An amount of 100 ppb sulfur is the maximum limit permitted for Siemens Westinghouse solid oxide fuel cells (SOFCs). The tested adsorbents include some that rely only on physical adsorption such as activated carbon, some that rely on chemisorption such as heated zinc oxide, and some that may use both processes. The testing was performed on an engineering scale with beds larger than those used for typical laboratory tests. All tests were done at about 3.45 barg (50 psig). The natural gas used for testing was from the local pipeline in Pittsburgh and averaged 6 ppm volume total sulfur. The primary sulfur species were dimethyl sulfide (DMS), isopropyl mercaptan, tertiary butyl mercaptan, and tetrahydrothiophene. Some tests required several months to achieve a sulfur breakthrough of the bed. It was found that DMS always came through a desulfurizer bed first, independent of adsorption process. Since the breakthrough of DMS always exceeds the 100 ppb SOFC sulfur limit before other sulfurs were detected, an index was created to rate the adsorbents in units of ppm DMS × absorbent bed volume. This index is useful for calculating the expected adsorbent bed lifetime before sulfur breakthrough when the inlet natural gas DMS content is known. The adsorbents that are included in these reports were obtained from suppliers in the United States, the Netherlands, Japan, and England. Three activated carbons from different suppliers were found to have identical performance in removing DMS. One of these activated carbons was operated at four different space velocities and again showed the same performance. When using activated carbon as the basis of comparison for other adsorbents, three high-performance adsorbents

  7. The results of the KSTAR superconducting coil test

    International Nuclear Information System (INIS)

    The KSTAR (Korea Superconducting Tokamak Advanced Research) device is under construction using superconducting (SC) coils for long pulse operation. The KSTAR superconducting magnet system consists of 16 D-shaped toroidal field (TF) coils, 3 pairs of poloidal field (PF) coils, and 4 pairs of central solenoid (CS) coils. Two kinds of SC coils have been fabricated and tested in the coil test facility in the Korea Basic Science Institute (KBSI). One of the coils was a prototype TF coil, TF00 coil, which has been fabricated in the same size as the real coils using Nb3Sn SC cable-in-conduit conductor (CICC). The other was a pair of CS model coils, which were fabricated as a part of a background field system to test the superconductor in a pulsed field environment. The major objectives of the SC coil tests were (i) to verify the coil design and fabrication process in the KSTAR coil development, (ii) to measure the coil performances during cool-down, current excitation, and discharge scenarios, and (iii) to achieve the operational experience of the SC coil test facility and the SC magnet system in the KSTAR device. The prototype TF coil was cooled down to the operating temperature of 4.5 K in 10 days. The coil was charged in steps and this was followed by slow or fast discharges. The transient hydraulic parameters were measured according to the different scenarios. The results of the coil test showed that no noticeable defects of the coil were found, such as helium leaks at cryogenic temperature, and helium circulation through the coil was sufficient to keep the coil at the operating temperature. The CS model coil was also cooled down in 9 days and basic current excitation and discharge tests of the coil have been done. To assess the ac performance of the coil, current charging experiments of the coil will be continued until the end of 2004. In this paper, the experimental results of the prototype TF coil and the CS model coil are described as well as the general coil test

  8. Results of testing the LPT-110 heavy hydraulic hammers

    Energy Technology Data Exchange (ETDEWEB)

    Kralev, I.; Georgiev, G.; Uzunov, Kh.; Mitkov, K.; Rashkeev, N.

    1988-03-01

    Outlines results of tests on five prototype Bulgarian hydraulic drill hammers - the LPT-110.1, LPT-110.2, LPT-110.3, LPT-110.4 and LPT-110.6 produced by te Probivna Tekhnika laboratory. Three aspects of performance were tested by the Mintyazhmash factory laboratory in the USSR; (1) energy of individual piston blows, (2) blow frequency (blows/min), (3) consumption of working fluid. Technical characteristics are summarized in a table for piston diameters of 58 and 72 mm, stroke length of 50 mm, drilling power from 4.80-15.75 kW, hydraulic fluid working pressure 8.9-12.7 MPa, fluid consumption 80-160 dm/min. Results are presented in three tbles and one diagram. Manufacture of these hammers by the MeGIKoo association should begin in early 1989.

  9. Influence of Blood Lipids on Global Coagulation Test Results

    OpenAIRE

    Kim, Jung-Ah; Kim, Ji-Eun; Song, Sang Hoon; Kim, Hyun Kyung

    2014-01-01

    Background High levels of blood lipids have been associated with high levels of coagulation factors. We investigated whether blood lipids influence the results of global coagulation tests, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA). Methods PT, aPTT, and TGA, along with procoagulant and anticoagulant factors, were measured in 488 normal individuals. Vitamin K status was assessed with prothrombin-induced by vitamin K absen...

  10. Gridded gun test results for dual mode medical Linac

    International Nuclear Information System (INIS)

    As an advancement in the current low energy (6 MV) radiotherapy linac technology, SAMEER is developing a dual photon energy linac capable of giving 6 and 15 MV photons and multiple electron energies (6, 8, 10, 12, 14, 16 and 18 MeV) for electron treatment. The main feature of this development is to produce clinically acceptable quality electron beam and photon beam. The gridded gun development is a crucial part of this project because of the electron beam current requirement which ranges from milliampere to nanoampere level from photon mode to electron mode. Therefore, precise control on the beam current is key feature in linac operation. The gridded gun design specifications is given. The gun assembly was successfully carried out. The gridded gun was assembled in a test jig and baked at 100 °C. The vacuum achieved after baking was ∼10-9 mbar. The cathode activation results and DC test results were obtained. The high voltage test results in pulsed mode is discussed in this paper along with its supply. (author)

  11. Small-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, G. N.; Mahoney, Lenna A.; Tran, Diana N.; Burns, Carolyn A.; Kurath, Dean E.

    2013-08-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the

  12. Utility Test Results of a 2-Megawatt, 10-Second Reserve-Power System

    Energy Technology Data Exchange (ETDEWEB)

    BALL,GREG J.; NORRIS,BENJAMIN L.

    1999-10-01

    This report documents the 1996 evaluation by Pacific Gas and Electric Company of an advanced reserve-power system capable of supporting 2 MW of load for 10 seconds. The system, developed under a DOE Cooperative Agreement with AC Battery Corporation of East Troy, Wisconsin, contains battery storage that enables industrial facilities to ''ride through'' momentary outages. The evaluation consisted of tests of system performance using a wide variety of load types and operating conditions. The tests, which included simulated utility outages and voltage sags, demonstrated that the system could provide continuous power during utility outages and other disturbances and that it was compatible with a variety of load types found at industrial customer sites.

  13. Battery Thermal Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Keyser, Matthew; Saxon, Aron; Powell, Mitchell; Shi, Ying

    2016-06-07

    This poster shows the progress in battery thermal characterization over the previous year. NREL collaborated with U.S. DRIVE and USABC battery developers to obtain thermal properties of their batteries, obtained heat capacity and heat generation of cells under various power profiles, obtained thermal images of the cells under various drive cycles, and used the measured results to validate thermal models. Thermal properties are used for the thermal analysis and design of improved battery thermal management systems to support achieve life and performance targets.

  14. Dynamical modeling procedure of a Li-ion battery pack suitable for real-time applications

    International Nuclear Information System (INIS)

    Highlights: • Dynamical modeling of a 50 A h battery pack composed of 56 cells. • Detailed analysis of SOC tests at realistic performance range imposed by BMS. • We propose an electrical circuit that improves how the battery capacity is modeled. • The model is validated in the SOC range using a real-time experimental setup. - Abstract: This paper presents the modeling of a 50 A h battery pack composed of 56 cells, taking into account real battery performance conditions imposed by the BMS control. The modeling procedure starts with a detailed analysis of experimental charge and discharge SOC tests. Results from these tests are used to obtain the battery model parameters at a realistic performance range (20–80% SOC). The model topology aims to better describe the finite charge contained in a battery pack. The model has been validated at three different SOC values in order to verify the model response at real battery pack operation conditions. The validation tests show that the battery pack model is able to simulate the real battery response with excellent accuracy in the range tested. The proposed modeling procedure is fully applicable to any Li-ion battery pack, regardless of the number of series or parallel cells or its rated capacity

  15. What Do the Results of Genetic Tests Mean?

    Science.gov (United States)

    ... can ask their healthcare professional. Topics in the Genetic Testing chapter What is genetic testing? What are the types of genetic tests? How is genetic testing done? What is informed consent? What is direct- ...

  16. Results of 30 second engineering testing of the LBL APIS

    International Nuclear Information System (INIS)

    Engineering testing for MFTF-B of the LBL Advanced Positive Ion Source (APIS) ha recently been completed on the NBETF test stand. 500 shots of 30 seconds were run at 80 kV, 42A, deuterium. Optimum perveance was 1.85 μpervs, with divergence 0.350 X 0.950. Species was measured with an Optical Multichannel Analyzer (OMA), 87/10/3, full, half and third energy. The water fraction was at the limit of OMA resolution, ≤0.2%. Gas flow was 12 T1/s, which is below equilibrium for the NBETF neutralizer, but correct for the MFTF-B beamline. Beam properties were the same at equilibrium flow, 17 T1/s. Results of these tests indicate that both the plasma source and accelerator are ready for industrialization for MFTF-B. Extrapolated filament life is 3 x 10/sup 3/ full power 30 second shots. Brief testing with hydrogen for GA gave 55A at 80 kV, for 5 seconds, at an optimum perpendicular divergence of 1.10

  17. Test results of autonomous behaviors for urban environment exploration

    Science.gov (United States)

    Ahuja, G.; Fellars, D.; Kogut, G.; Pacis Rius, E.; Sights, B.; Everett, H. R.

    2009-05-01

    Under various collaborative efforts with other government labs, private industry, and academia, SPAWAR Systems Center Pacific (SSC Pacific) is developing and testing advanced autonomous behaviors for navigation, mapping, and exploration in various indoor and outdoor settings. As part of the Urban Environment Exploration project, SSC Pacific is maturing those technologies and sensor payload configurations that enable man-portable robots to effectively operate within the challenging conditions of urban environments. For example, additional means to augment GPS is needed when operating in and around urban structures. A MOUT site at Camp Pendleton was selected as the test bed because of its variety in building characteristics, paved/unpaved roads, and rough terrain. Metrics are collected based on the overall system's ability to explore different coverage areas, as well as the performance of the individual component behaviors such as localization and mapping. The behaviors have been developed to be portable and independent of one another, and have been integrated under a generic behavior architecture called the Autonomous Capability Suite. This paper describes the tested behaviors, sensors, and behavior architecture, the variables of the test environment, and the performance results collected so far.

  18. Head-end demonstration test for nuclear fuel reprocessing plant. Outline of the test results

    International Nuclear Information System (INIS)

    Japan Nuclear Fuel Ltd. (JNFL) is now constructing a nuclear fuel reprocessing plant (Rokkasho Reprocessing Plant) at Rokkasho-mura. Concerning the head-end process, which includes shearing and dissolving processes for spent fuel and rinsing processes for upper and lower end-pieces of spent fuel assemblies and chopped fuel rods, a full-scale mock-up test facility was constructed and functional and performance tests were performed using a dummy fuel assembly and chopped fuel rods. This paper summarizes results the tests conducted from 1988 to 1993 by Mitsubishi Heavy Industries, Ltd. (MHI). The head-end demonstration test (HEDT) facility includes five components: tilting crane, shearing machine, dissolver, hull rinser and end-piece rinser. The design of these components manufactured by MHI is based on SGN technology. The suitability of the design, the functional reliability, the operability, the controllability and the maintainability were evaluated through functional tests such as an operation test, a shearing test, a transfer test, a heating and cooling test and a remote maintenance test under cold (non radioactive) conditions. The test results were satisfactory. The component performance data and our manufacturing and operation experience will greatly facilitate the final design process and support the choice of operational parameters for these head-end components of the Rokkasho Reprocessing Plant. (author)

  19. Suit Port Aft Bulkhead Mockup Test Results and Lessons Learned

    Science.gov (United States)

    Romig, Barbara A.; Allton, Charles

    2009-01-01

    The Small Pressurized Rover (SPR) is currently being carried as an integral part of the current Lunar Surface Architectures under consideration in the Constellation program. One element of the SPR is the suit port, the means by which the crew performs Extravehicular Activities (EVAs). Two suit port deliverables were produced in fiscal year 2008: an aft bulkhead mockup for functional integrated testing with the 1-G SPR mockup and a functional and pressurizable engineering unit. This paper focuses on the test results and lessons learned on the aft bulkhead mockup. The suit port aft bulkhead mockup was integrated with the mockup of the SPR cabin and chassis. It is located on the aft bulkhead of the SPR cabin structure and includes hatches, a locking mechanism, seals, interior and exterior suit don/doff aids, and exterior platforms to accommodate different crewmember heights. A lightweight mockup of the Mark III suit was tested with the suit port aft bulkhead mockup. There are several limitations to the suit port and mockup suits, and results of the suit port evaluation are presented and interpreted within the context of the limitations.

  20. Evaluation of results of benchmark test on CCF

    International Nuclear Information System (INIS)

    A benchmark test on common cause failures (CCF) was performed giving interested institutions in Germany the opportunity to demonstrate and justify their interpretations of events, their methods and models for analyzing CCF. The task for the benchmark test was to analyze two typical groups of motor-operated valves in German nuclear power plants. In this report the progress and the results of the benchmark are summarized and assessed by GRS. Furthermore, resulting proposals are given for the ongoing development of the PSA-documents. The benchmark test was carried out in two steps. In the first step the participants were to assess in a qualitative way some 200 event-reports on isolation valves. They then were to establish, quantitatively, the reliability parameters for the CCF in the two groups of motor-operated valves, using their own methods and their own calculation models. In a second step the reliability parameters were to be recalculated on the basis of a common reference of well defined events, chosen from all given events, in order to analyze the influence of the calculation models on the reliability parameters. (orig.)

  1. Beam Test Results of the GlueX Forward Calorimeter

    Science.gov (United States)

    Bauer, Kevin; Moriya, Kei; Shepherd, Matthew

    2013-04-01

    GlueX is an experiment to begin running in the near future at Jefferson Lab. Our research group is responsible for the forward calorimeter (FCAL) that is designed to measure the energy of photons produced from the decays of mesons. Recently, we conducted a beam test at Jefferson Lab using a prototype of the FCAL. Its goal was to experimentally verify the energy resolution of the FCAL as a function of beam energy. The prototype was tested with recoil electrons ranging in energy from 113MeV to 277MeV. We obtained the resolution by comparing the reconstructed energy to the known energy. In addition, we corrected our measured resolution for multiple scattering and energy loss based on a GEANT4 simulation of the prototype. Another important goal of the beam test was to measure the timing resolution of the channels on our flash analog to digital converters (fADCs). For GlueX, we need to require the timing resolution to be much less than the bunch spacing (2ns). The results of our studies indicate that the energy resolution of the FCAL is consistent with our predictions. We also found the timing resolution as a function of signal size and the results agreed with a similar study. For signals of about at least 75mV, the timing resolution achieved was significantly lower than 2ns.

  2. The UltraBattery-A new battery design for a new beginning in hybrid electric vehicle energy storage

    Science.gov (United States)

    Cooper, A.; Furakawa, J.; Lam, L.; Kellaway, M.

    The UltraBattery, developed by CSIRO Energy Technology in Australia, is a hybrid energy storage device which combines an asymmetric super-capacitor and a lead-acid battery in single unit cells. This takes the best from both technologies without the need for extra, expensive electronic controls. The capacitor enhances the power and lifespan of the lead-acid battery as it acts as a buffer during high-rate discharging and charging, thus enabling it to provide and absorb charge rapidly during vehicle acceleration and braking. The initial performance of the prototype UltraBatteries was evaluated according to the US FreedomCAR targets and was shown to meet or exceed these in terms of power, available energy, cold cranking and self-discharge set for both minimum and maximum power-assist hybrid electric vehicles (HEVs). Other laboratory cycling tests showed a fourfold improvement over previous state-of-the-art lead-acid batteries under the RHOLAB test profile and better life than commercial nickel/metal hydride (NiMH) cells used in a Honda Insight when tested under the EUCAR HEV profile. As a result of this work, a set of twelve 12 V modules was built by The Furukawa Battery Co., Ltd. in Japan and were fitted into a Honda Insight instead of the NiMH battery by Provector Ltd. The battery pack was fitted with full monitoring and control capabilities and the car was tested at Millbrook Proving Ground under a General Motors road test simulation cycle for an initial target of 50 000 miles which was extended to 100 000 miles. This was completed on 15th January 2008 without any battery problems. Furthermore, the whole test was completed without the need for any conditioning or equalisation of the battery pack.

  3. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  4. High School Staff Characteristics and Mathematics Test Results

    Directory of Open Access Journals (Sweden)

    Mark Fetler

    1999-03-01

    Full Text Available This study investigates the relationship between measures of mathematics teacher skill and student achievement in California high schools. Test scores are analyzed in relation to teacher experience and education and student demographics. The results are consistent with the hypotheses that there is a shortage of qualified mathematics teachers in California and that this shortage is associated with low student scores in mathematics. After controlling for poverty, teacher experience and preparation significantly predict test scores. Short-term strategies to increase the supply of qualified mathematics teachers could include staff development, and recruitment incentives. A long-term strategy addressing root causes of the shortage requires more emphasis on mathematics in high school and undergraduate programs.

  5. Beam Test Results of High Q CBPM prototype for SXFEL

    CERN Document Server

    Chen, Jian; Yu, Luyang; Lai, Longwei; Yuan, Renxian

    2016-01-01

    Aiming at high precision beam position measurement of micron or sub-micron for Shanghai Soft X-ray free electron laser (SXFEL) facility which is being built in site of the Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute of Applied Physics has developed a high Q cavity beam position monitor (CBPM) that the resonant frequency is 4.7 GHz and relevant BPM electronics include dedicated RF front-end and home-made digital BPM (DBPM) also has been done. The cavity design, cold test, system architecture and the beam test with three adjacent pickups has been performed in Shanghai Deep ultraviolet free electron laser(SDUV-FEL) facility are included. The beam experiment results show that the physical design of our CBPM is consistent with the expectations basically and the beam position resolution can fulfill the resolution requirements for the SXFEL project if we optimize the beam conditions.

  6. The Next Linear Collider test accelerator: Status and results

    International Nuclear Information System (INIS)

    At SLAC, the authors are pursuing the design of a Next Linear Collider (NLC) which would begin with a center-of-mass energy of 0.5 TeV, and would be upgradable to 1.0 TeV and beyond. To achieve this high energy, for the past several years they have been working on the development of a high-gradient 11.4-GHz (X-band) linear accelerator for the main linac of the collider. In this paper, they present the status and initial results from the ''Next Linear Collider Test Accelerator'' (NLCTA). The goal of the NLCTA is to model the high gradient linac of the NLC. It incorporates the new technologies of X-band accelerator structures, rf pulse compression systems and high-power klystrons into a 0.5 to 1.0 GeV linac which is a test bed for beam dynamics issues related to high-gradient acceleration

  7. Preliminary Results of Testing of Flow Effects on Evaporator Scaling

    Energy Technology Data Exchange (ETDEWEB)

    Hu, M.Z.

    2002-02-15

    This investigation has focused on the effects of fluid flow on solids deposition from solutions that simulate the feed to the 2H evaporator at the Savannah River Site. Literature studies indicate that the fluid flow (or shear) affects particle-particle and particle-surface interactions and thus the phenomena of particle aggregation in solution and particle deposition (i.e., scale formation) onto solid surfaces. Experimental tests were conducted with two configurations: (1) using a rheometer to provide controlled shear conditions and (2) using controlled flow of reactive solution through samples of stainless steel tubing. All tests were conducted at 80 C and at high silicon and aluminum concentrations, 0.133 M each, in solutions containing 4 M sodium hydroxide and 1 A4 each of sodium nitrate and sodium nitrite. Two findings from these experiments are important for consideration in developing approaches for reducing or eliminating evaporator scaling problems: (1) The rheometer tests suggested that for the conditions studied, maximum solids deposition occurs at a moderate shear rate, approximately 12 s{sup -1}. That value is expected to be on the order of shear rates that will occur in various parts of the evaporator system; for instance, a 6 gal/min single-phase liquid flow through the 2-in. lift or gravity drain lines would result in a shear rate of approximately 16 s{sup -1}. These results imply that engineering approaches aimed at reducing deposits through increased mixing would need to generate shear near all surfaces significantly greater than 12 s{sup -1}. However, further testing is needed to set a target value for shear that is applicable to evaporator operation. This is because the measured trend is not statistically significant at the 95% confidence interval due to variability in the results. In addition, testing at higher temperatures and lower concentrations of aluminum and silicon would more accurately represent conditions in the evaporator. Without

  8. Test Results of a Network Switch Device for SMART MMIS

    International Nuclear Information System (INIS)

    SMART MMIS has been designed using fully digitalized systems. Non-safety instrumentation and control (I and C) systems are designed based on commercially distributed control systems. The safety I and C systems are designed using a new platform, which was developed and validated by KAERI. Safety I and C systems are modularized using the platform and communicate with each other using a communication board (CMB) and network switching device (NSD). The NSD of this paper has a deterministic behavior for industrial or nuclear application, where process data or control data has to be delivered within a certain time limit. The NSD has been developed and tested at KAERI since 2009. This paper presents the development and test results of the NSD

  9. Test results of LHC interaction regions quadrupoles produced by Fermilab

    CERN Document Server

    Fehér, S; Carson, J; Chichili, D R; Kerby, J; Lamm, M J; Nicol, T; Nobrega, A; Ogitsu, T; Orris, D; Page, T; Peterson, T; Rabehl, Roger Jon; Robotham, W; Scanlan, R; Schlabach, P; Strait, J; Sylvester, C D; Tartaglia, M; Tompkins, J C; Velev, G; Yadav, S; Zlobin, A V

    2005-01-01

    The US-LHC Accelerator Project is responsible for the production of the Q2 optical elements of the final focus triplets in the LHC interaction regions. As part of this program Fermilab is in the process of manufacturing and testing cryostat assemblies (LQXB) containing two identical quadrupoles (MQXB) with a dipole corrector between them. The 5.5 m long Fermilab designed MQXB have a 70 mm aperture and operate in superfluid helium at 1.9 K with a peak field gradient of 215 T/m. This paper summarizes the test results of several production MQXB quadrupoles with emphasis on quench performance and alignment studies. Quench localization studies using quench antenna signals are also presented.

  10. Results of MACE tests M0 and M1

    International Nuclear Information System (INIS)

    The Melt Attack and Coolability Experiment (MACE) Program underway at Argonne National Laboratory under ACE/EPRI sponsorship is addressing the efficacy of water to terminate an accident situation if melt progression were to result in a molten core/concrete interaction (MCCI) in a reactor containment. Large-scale experiments are being conducted, in parallel with related modeling efforts, involving the addition of water to an MCCI already underway. The experiments utilize UO2/ZrO2/Zr corium mixtures, direct electrical heating for simulation of decay heating, and various types of concrete basemats. Currently the tests involve 430 kg corium mass, 25 cm depth, in a 50 cm square test section. Test M0 was a successful scoping test, but the first full size test, M1, failed to achieve melt-water contact owing to existence of a preexisting bridge crust of corium charge. A heat flux of 3.5 MW/m2 was measured in M0 which removed energy from the corium pool equivalent to its entire heat of solidification prior to abatement by formation of an interfacial crust. The crust subsequently limited heat extraction to 600 kW/m2 and less. Both tests M0 and M1 revealed physical evidence of large pool swelling events which resulted in extrusion (and ejection) of melt into water above the crust, significantly increasing the overall quench and reducing the remaining melt in contact with the concrete. Furthermore, test M1 provided evidence of occasional 'burst mode' ablation events and one additional important benefit of overlying water-aerosol capture. In summary: Both MACE tests M0 and M1 contributed important information to the MCCI and melt coolability data base. Melt-water contact was achieved in M0, but after a period of intense energy removal a bridge crust formed which thereafter separated the water from the melt zone. Melt-water contact was not achieved in M1 owing to presence of a bridge crust as an initial condition. Key findings are summarized as follows: 1) The melt

  11. Communication of Advanced Test Reactor probabilistic risk assessment results

    International Nuclear Information System (INIS)

    The Advanced Test Reactor (ATR) probabilistic risk assessment (PRA) Level 1 results were efficiently communicated in two reports following the completion of revision 1 of the ATR PRA. As the ATR PRA including external events fills four large volume, it was considered impractical to expect all of the individuals at ATR who could benefit from the information to read the entire PRA. Even though many ATR personnel received training in PRA methodology and were involved in some aspects of the PRA, another hinderance to effective communication of the PRA results is that the PRA was written and organized to meet the requirements of practitioners and reviewers who are well-versed in PRA methods. Therefore, two PRA summary reports, an ATR risk summary report and an ATR functional group summary report, were written to communicate the ATR PRA results and insights to interested ATR personnel

  12. Testing ESL pragmatics development and validation of a web-based assessment battery

    CERN Document Server

    Roever, Carsten

    2014-01-01

    Although second language learners' pragmatic competence (their ability to use language in context) is an essential part of their general communicative competence, it has not been a part of second language tests. This book helps fill this gap by describing the development and validation of a web-based test of ESL pragmalinguistics. The instrument assesses learners' knowledge of routine formulae, speech acts, and implicature in 36 multiple-choice and brief-response items. The test's quantitative and qualitative validation with 300 learners showed high reliability and provided strong evidence of

  13. Expose : procedure and results of the joint experiment verification tests

    Science.gov (United States)

    Panitz, C.; Rettberg, P.; Horneck, G.; Rabbow, E.; Baglioni, P.

    The International Space Station will carry the EXPOSE facility accommodated at the universal workplace URM-D located outside the Russian Service Module. The launch will be affected in 2005 and it is planned to stay in space for 1.5 years. The tray like structure will accomodate 2 chemical and 6 biological PI-experiments or experiment systems of the ROSE (Response of Organisms to Space Environment) consortium. EXPOSE will support long-term in situ studies of microbes in artificial meteorites, as well as of microbial communities from special ecological niches, such as endolithic and evaporitic ecosystems. The either vented or sealed experiment pockets will be covered by an optical filter system to control intensity and spectral range of solar UV irradiation. Control of sun exposure will be achieved by the use of individual shutters. To test the compatibility of the different biological systems and their adaptation to the opportunities and constraints of space conditions a profound ground support program has been developed. The procedure and first results of this joint Experiment Verification Tests (EVT) will be presented. The results will be essential for the success of the EXPOSE mission and have been done in parallel with the development and construction of the final hardware design of the facility. The results of the mission will contribute to the understanding of the organic chemistry processes in space, the biological adaptation strategies to extreme conditions, e.g. on early Earth and Mars, and the distribution of life beyond its planet of origin.

  14. Test results of the SMES model coil. Mechanical performance

    International Nuclear Information System (INIS)

    The mechanical performance of a SMES model coil was measured by strain gauges, displacement gauges and acoustic emission (AE) sensors attached to the coil surface during an overcharge test. The displacements of the SMES model coil were proportional to the squared currents during charging up until 35.4 kA. It was clear that the coil became deformed elastically by the electromagnetic force during overcharging. The test results obtained by the measurement of strains were compared with calculated results obtained by finite element method analysis. As a result of the comparison, good agreement was found in both stresses, and the values were sufficiently small. It was demonstrated that the coil had no problem regarding mechanical performance. It was clarified that AE signals significantly decreased in the current region after repeated excitation. Furthermore, the characteristics of AE signals were different from the coil windings with coil supports. The wave of AE signals in the windings was minimal ms and more than 100 kHz, and in the coil support more than 10 ms but less than 40 kHz. (author)

  15. Hanford coring bit temperature monitor development testing results report

    International Nuclear Information System (INIS)

    Instrumentation which directly monitors the temperature of a coring bit used to retrieve core samples of high level nuclear waste stored in tanks at Hanford was developed at Sandia National Laboratories. Monitoring the temperature of the coring bit is desired to enhance the safety of the coring operations. A unique application of mature technologies was used to accomplish the measurement. This report documents the results of development testing performed at Sandia to assure the instrumentation will withstand the severe environments present in the waste tanks

  16. Assessing Equivalent Viscous Damping Using Piping System test Results

    Energy Technology Data Exchange (ETDEWEB)

    Nie, J.; Morante, R.

    2010-07-18

    The specification of damping for nuclear piping systems subject to seismic-induced motions has been the subject of many studies and much controversy. Damping estimation based on test data can be influenced by numerous factors, consequently leading to considerable scatter in damping estimates in the literature. At present, nuclear industry recommendations and nuclear regulatory guidance are not consistent on the treatment of damping for analysis of nuclear piping systems. Therefore, there is still a need to develop a more complete and consistent technical basis for specification of appropriate damping values for use in design and analysis. This paper summarizes the results of recent damping studies conducted at Brookhaven National Laboratory.

  17. Hydrogen-burn survival: preliminary thermal model and test results

    Energy Technology Data Exchange (ETDEWEB)

    McCulloch, W.H.; Ratzel, A.C.; Kempka, S.N.; Furgal, D.T.; Aragon, J.J.

    1982-08-01

    This report documents preliminary Hydrogen Burn Survival (HBS) Program experimental and analytical work conducted through February 1982. The effects of hydrogen deflagrations on safety-related equipment in nuclear power plant containment buildings are considered. Preliminary results from hydrogen deflagration experiments in the Sandia Variable Geometry Experimental System (VGES) are presented and analytical predictions for these tests are compared and discussed. Analytical estimates of component thermal responses to hydrogen deflagrations in the upper and lower compartments of an ice condenser, pressurized water reactor are also presented.

  18. Hydrogen-burn survival: preliminary thermal model and test results

    International Nuclear Information System (INIS)

    This report documents preliminary Hydrogen Burn Survival (HBS) Program experimental and analytical work conducted through February 1982. The effects of hydrogen deflagrations on safety-related equipment in nuclear power plant containment buildings are considered. Preliminary results from hydrogen deflagration experiments in the Sandia Variable Geometry Experimental System (VGES) are presented and analytical predictions for these tests are compared and discussed. Analytical estimates of component thermal responses to hydrogen deflagrations in the upper and lower compartments of an ice condenser, pressurized water reactor are also presented

  19. Regenerable Microbial Check Valve - Life cycle tests results

    Science.gov (United States)

    Atwater, James E.; Wheeler, Richard R., Jr.; Olivadoti, J. T.; Sauer, Richard L.; Flanagan, David T.

    1992-01-01

    Life cycle regeneration testing of the Microbial Check Valve (MCV) that is used on the Shuttle Orbiter to provide microbial control of potable water is currently in progress. Four beds are being challenged with simulated reclaimed waters and repeatedly regenerated. Preliminary results indicate that contaminant systems exhibit unique regeneration periodicities. Cyclic throughput diminishes with increasing cumulative flow. It is considered to be feasible to design a regenerable MCV system which will function without human intervention and with minimal resupply penalty for the 30 year life of the Space Station.

  20. Bayesian model mixing for cold rolling mills: Test results

    Czech Academy of Sciences Publication Activity Database

    Ettler, P.; Puchr, I.; Dedecius, Kamil

    Slovensko: Slovak University of Technology, 2013, s. 359-364. ISBN 978-1-4799-0926-1. [19th International Conference on Process Control . Štrbské Pleso (SK), 18.06.2013-21.06.2013] R&D Projects: GA MŠk(CZ) 7D09008; GA MŠk 7D12004 Keywords : Bayesian statistics * model mixing * process control Subject RIV: BC - Control Systems Theory http://library.utia.cas.cz/separaty/2013/AS/dedecius-bayesian model mixing for cold rolling mills test results.pdf

  1. A System Engineering Approach To The Design And Testing Of Battery Vehicle Drives

    OpenAIRE

    Edwards, J B; Pacey, K

    1980-01-01

    The dynamic laboratory testing of prototype drives is discussed:a minicomputer controlling load and drive simultaneously. The roles of inverse Nyquist analysis, sampled- data systems analysis and computer simulation in design and commissioning are examined.

  2. Test Results for LHC Insertion Region Dipole Magnets

    CERN Document Server

    Muratore, Joseph F; Cozzolino, John P; Ganetis, George; Ghosh, Arup; Gupta, Ramesh C; Harrison, Michael; Kumar-Jain, Animesh; Marone, Andrew; Richard-Plate, Stephen; Schmalzle, Jesse D; Thomas, Richard A; Wanderer, Peter; Willen, Erich; Wu, Kuo-Chen

    2005-01-01

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They produce fields up to 3.8 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, which have the most challenging design. In these, the dipole fields in both apertures point in the same direction, unlike LHC arc dipoles. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality. Magnetic field measurements were done at 4.5K and at room temperature, and warm-...

  3. LUCIFER: status and results of the hardware testing

    Science.gov (United States)

    Seifert, Walter; Laun, Werner; Lehmitz, Michael; Mandel, Holger; Schuetze, Andreas; Seltmann, Andreas

    2004-09-01

    LUCIFER (LBT NIR-Spectroscopic Utility with Camera and Integral-Field Unit for Extragalactic Research) is a NIR spectrograph and imager (wavelength range 0.9 to 2.5 micron) for the Large Binocular Telescope (LBT) on Mt. Graham, Arizona. It is built by a consortium of five German institutes and will be one of the first light instruments for the LBT. Later, a second copy for the second mirror of the telescope will follow. Both instruments will be mounted at the bent Gregorian foci of the two individual telescope mirrors. The instrument is equipped with three exchangeable cameras for imaging and spectroscopy: two of them are optimized for seeing-limited conditions, the third camera for the diffraction-limited case with the LBT adaptive secondary mirror working. The spectral resolution will allow for OH suppression. Up to 33 exchangeable masks will be available for longslit and multi-object spectroscopy (MOS) over the full field of view (FOV). The detector will be a Rockwell HAWAII-2 HgCdTe-array. Extensive tests were done for all the electro-mechanical functions. Those include the grating selection and the grating tilt unit and the drive for the fold mirror to compensate for image movement due to flexure. Furthermore several optical and opto-mechanical units were tested. The procedures and results of the tests are presented in detail and compared with the specifications.

  4. Preliminary results of the LAT Calibration Unit beam tests

    International Nuclear Information System (INIS)

    The calibration strategy of the GLAST Large Area Telescope (LAT) combines analysis of cosmic ray data with accelerator particle beams measurements. An advanced Monte Carlo simulation of the LAT, based on the Geant4 package, was set up to reproduce the LAT response to such radiation and to benchmark the event reconstruction and the background rejection strategy before launch and during operation. To validate the LAT simulation, a massive campaign of beam tests was performed between July and November 2006, in parallel with the LAT integration and test, on the LAT Calibration Unit. This is a detector built with spare flight modules and flight-like readout electronics, which was exposed to a large variety of beams, representing the whole spectrum of the signal that will be detected by the LAT, using the CERN and the GSI accelerator facilities. Beams of photons (0 - 2.5 GeV), electrons (1 - 300 GeV), hadrons (π and p, a few GeV - 100 GeV) and ions (C; Xe, 1.5 GeV/n) were shot through the CU to measure the physical processes taking place in the detector and eventually fine-tune their description in the LAT Monte Carlo simulation. This paper describes the motivations and goals of the test runs, the many different experimental setups used, the measured detector performance and preliminary results of the LAT Monte Carlo validation

  5. Preliminary Results of the LAT Calibration Unit Beam Tests

    International Nuclear Information System (INIS)

    The calibration strategy of the GLAST Large Area Telescope (LAT) combines analysis of cosmic ray data with accelerator particle beams measurements. An advanced Monte Carlo simulation of the LAT, based on the Geant4 package, was set up to reproduce the LAT response to such radiation and to benchmark the event reconstruction and the background rejection strategy before launch and during operation. To validate the LAT simulation, a massive campaign of beam tests was performed between July and November 2006, in parallel with the LAT integration and test, on the LAT Calibration Unit. This is a detector built with spare flight modules and flight-like readout electronics, which was exposed to a large variety of beams, representing the whole spectrum of the signal that will be detected by the LAT, using the CERN and the GSI accelerator facilities. Beams of photons (0 - 2.5 GeV), electrons (1 - 300 GeV), hadrons (p and p, a few GeV - 100 GeV) and ions (C Xe, 1.5 GeV/n) were shot through the CU to measure the physical processes taking place in the detector and eventually fine-tune their description in the LAT Monte Carlo simulation. This paper describes the motivations and goals of the test runs, the many different experimental setups used, the measured detector performance and preliminary results of the LAT Monte Carlo validation

  6. Solid-state gyrotron body power supply, test results

    Energy Technology Data Exchange (ETDEWEB)

    Santinelli, M. [Association Euratom-ENEA, ENEA CR Frascati, 00044 Frascati (Italy)], E-mail: santinelli@frascati.enea.it; Claesen, R.; Coletti, A. [Association Euratom-ENEA, ENEA CR Frascati, 00044 Frascati (Italy); Bonicelli, T.; Mondino, P.L. [EFDA, EFDA CSU Garching, D-85748 Garching (Germany); Pretelli, M.; Rinaldi, L.; Sita, L.; Taddia, G. [OCEM SpA, Via 2 Agosto 1980 no. 11, 40016 San Giorgio di Piano (Italy)

    2007-10-15

    A 170 GHz, 2 MW, steady-state gyrotron is being developed in collaboration between European research associations and industries to be used for the electron cyclotron resonance heating (ECRH) system of ITER, the gyrotron is presently in the prototype state. EFDA entrusted ENEA with the design of a new power supply for the gyrotron's body; in which, the traditional power vacuum tubes are replaced with solid-state components (IGBT); furthermore ENEA had the task of developing the new body power supply (BPS), following the initial conceptual design. The BPS is formed by 50 identical bidirectional (in current) modules, connected in series; the BPS's control system regulates the output voltage by changing the modulation index. OCEM Spa, under ENEA's supervision, has manufactured the BPS. Tests, done at the start of this year, showed the substantial agreement between the initial technical specifications and the values achieved. Particularly the ramp-up/down-emergency time (50-10 {mu}s), the accuracy ({+-}0.5%), the sine wave modulation (45-20 kV at 5 kHz) and the maximum phase shift (<10 deg.) have been tested. In the article, the new stair-way modulation (SWM) scheme will be sketched and the test results will be described in detail.

  7. Results of formate ion additive tests at EPRI's High Sulfur Test Center

    International Nuclear Information System (INIS)

    This paper presents the results of a two-part test program conducted on the 0.4-MWe mini-pilot wet limestone FGD system at the Electric Power Research Institute's (EPRI) High Sulfur Test Center (HSTC). The primary objectives of the tests were to evaluate the effects of the formate ion on FGD system operation and performance and to measure the formate consumption rates for a variety of operating conditions. Tests were run under natural-, inhibited-, and forced-oxidation conditions. Results are presented which show how system performance varied with formate ion concentrations up to 4500 ppm. Other independent test variables included recycle slurry pH, process liquor chemistry, limestone grind, and reaction tank volume. Process performance results include the effects of formate on SO2 removal efficiency, limestone utilization, sulfite oxidation, and waste solids properties. These results show that significant enhancement of SO2 removal efficiency can be achieved at relatively low formate concentrations for a wide range of test conditions. Total formate consumption results are presented along with estimates of the relative losses attributable to the three primary consumption mechanisms vaporization, coprecipitation, and chemical degradation. In the mini-pilot tests, the lowest consumption rates were measured when formate was used in combination with the thiosulfate ion (i.e., under inhibited-oxidation conditions), while the highest consumption rates were measured under forced-oxidation conditions

  8. Experimental results of multi-channel test of T1 test section, 1

    International Nuclear Information System (INIS)

    Uniform power distribution tests were performed with the multi-channel test rig of fuel stack test section (T1). The moderate-temperature heater rods with uniform heat flux distribution were used in the tests. Experimental results are summerized as follows: (1) Distribution of He gas flow rate in 12 coolant channels is almost uniform. The temperature distribution of graphite blocks is also uniform in the horizontal direction. (2) Radiative heat transfer rate from heater rod is about 20 % of the total heat transfer rate in a region of Re = 2000). (author)

  9. Electrochemical accumulators batteries; Accumulateurs electrochimiques batteries

    Energy Technology Data Exchange (ETDEWEB)

    Ansart, F.; Castillo, S.; Laberty- Robert, C.; Pellizon-Birelli, M. [Universite Paul Sabatier, Lab. de Chimie des Materiaux Inorganiques et Energetiques, CIRIMAT, UMR CNRS 5085, 31 - Toulouse (France)] [and others

    2000-07-01

    It is necessary to storage the electric power in batteries to join the production and the utilization. In this domain progresses are done every days in the technics and also in the available materials. These technical days present the state of the art in this domain. Many papers were presented during these two days giving the research programs and recent results on the following subjects: the lithium batteries, the electrolytes performances and behaviour, lead accumulators, economic analysis of the electrochemical storage market, the batteries applied to the transportation sector and the telephones. (A.L.B.)

  10. Aerodynamic and Acoustic Flight Test Results and Results for the Stratospheric Observatory for Infrared Astronomy

    Science.gov (United States)

    Cumming, Stephen B.; Smith, Mark S.; Cliatt, Larry J.; Frederick, Michael A.

    2014-01-01

    As part of the Stratospheric Observatory for Infrared Astronomy program, a 747SP airplane was modified to carry a 2.5-m telescope in the aft section of the fuselage. The resulting airborne observatory allows for observations above 99 percent of the water vapor in the atmosphere. The open cavity created by the modifications had the potential to significantly affect the airplane in the areas of aerodynamics and acoustics. Several series of flight tests were conducted to clear the operating envelope of the airplane for astronomical observations, planned to be performed between the altitudes of 35,000 ft and 45,000 ft. The flight tests were successfully completed. Cavity acoustics were below design limits, and the overall acoustic characteristics of the cavity were better than expected. The modification did have some effects on the stability and control of the airplane, but these effects were not significant. Airplane air data systems were not affected by the modifications. This paper describes the methods used to examine the aerodynamics and acoustic data from the flight tests and provides a discussion of the flight-test results in the areas of cavity acoustics, stability and control, and air data.

  11. Tc-99 Adsorption on Selected Activated Carbons - Batch Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Wellman, Dawn M.; Golovich, Elizabeth C.; Cordova, Elsa A.; Smith, Ronald M.

    2010-12-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently developing a 200-West Area groundwater pump-and-treat system as the remedial action selected under the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision for Operable Unit (OU) 200-ZP-1. This report documents the results of treatability tests Pacific Northwest National Laboratory researchers conducted to quantify the ability of selected activated carbon products (or carbons) to adsorb technetium-99 (Tc-99) from 200-West Area groundwater. The Tc-99 adsorption performance of seven activated carbons (J177601 Calgon Fitrasorb 400, J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, J177612 Norit GAC830, J177613 Norit GAC830, and J177617 Nucon LW1230) were evaluated using water from well 299-W19-36. Four of the best performing carbons (J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, and J177613 Norit GAC830) were selected for batch isotherm testing. The batch isotherm tests on four of the selected carbons indicated that under lower nitrate concentration conditions (382 mg/L), Kd values ranged from 6,000 to 20,000 mL/g. In comparison. Under higher nitrate (750 mg/L) conditions, there was a measureable decrease in Tc-99 adsorption with Kd values ranging from 3,000 to 7,000 mL/g. The adsorption data fit both the Langmuir and the Freundlich equations. Supplemental tests were conducted using the two carbons that demonstrated the highest adsorption capacity to resolve the issue of the best fit isotherm. These tests indicated that Langmuir isotherms provided the best fit for Tc-99 adsorption under low nitrate concentration conditions. At the design basis concentration of Tc 0.865 µg/L(14,700 pCi/L), the predicted Kd values from using Langmuir isotherm constants were 5,980 mL/g and 6,870 mL/g for for the two carbons. These Kd values did not meet the target Kd value of 9,000 mL/g. Tests

  12. Flight Test 4 Preliminary Results: NASA Ames SSI

    Science.gov (United States)

    Isaacson, Doug; Gong, Chester; Reardon, Scott; Santiago, Confesor

    2016-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements as well as the safety substantiation and end-to-end assessment of DAA system performance. The Unmanned Aircraft System (UAS) Integration into the National Airspace System (NAS) Project conducted flight test program, referred to as Flight Test 4, at Armstrong Flight Research Center from April -June 2016. Part of the test flights were dedicated to the NASA Ames-developed Detect and Avoid (DAA) System referred to as JADEM (Java Architecture for DAA Extensibility and Modeling). The encounter scenarios, which involved NASA's Ikhana UAS and a manned intruder aircraft, were designed to collect data on DAA system performance in real-world conditions and uncertainties with four different surveillance sensor systems. Flight test 4 has four objectives: (1) validate DAA requirements in stressing cases that drive MOPS requirements, including: high-speed cooperative intruder, low-speed non-cooperative intruder, high vertical closure rate encounter, and Mode CS-only intruder (i.e. without ADS-B), (2) validate TCASDAA alerting and guidance interoperability concept in the presence of realistic sensor, tracking and navigational errors and in multiple-intruder encounters against both cooperative and non-cooperative intruders, (3) validate Well Clear Recovery guidance in the presence of realistic sensor, tracking and navigational errors, and (4) validate DAA alerting and guidance requirements in the presence of realistic sensor, tracking and navigational errors. The results will be

  13. Head-end demonstration test for nuclear fuel reprocessing plant 'outline of the test results'

    International Nuclear Information System (INIS)

    Japan Nuclear Fuel Ltd. (JNFL) is now constructing a nuclear fuel reprocessing plant at Rokkasho-mura (which is called Rokkasho Reprocessing plant). Concerning the head-end process, which includes shearing and dissolving processes for spent fuel and rinsing processes for end-pieces of spent fuel assemblies and chopped fuel rods, a full-scale mock-up test facility was constructed in Kobe Shipyard of Mitsubishi Heavy Industries, LTD (MHI). And then, functional and performance tests were performed using a dummy fuel assembly and chopped fuel rods, from 1988 to 1993. These tests using this full-scale mock-up test facility was called head-end demonstration test (HEDT), and this paper summarizes the results of HEDT. This HEDT facility includes five components: tilting crane, shearing machine, dissolver, hull rinser and end-piece rinser. The design of these components manufactured by MHI is based on CEA/COGEMA/SGN technology. The suitability of the design, the functional reliability, the operability, the controllability and the maintenability were evaluated through functional tests such as an operation test, for example a shearing test, under cold conditions (non radioactive). It was demonstrated that the test results were satisfactory. The component performance data and our manufacturing and operation experience will be greatly useful for the final design process and the choice of operational parameters for these head-end components of the Rokkasho Reprocessing Plant. (author)

  14. Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus

    Science.gov (United States)

    Russell, Carl R.

    2014-01-01

    Prior to the full-scale wind tunnel test of the UH-60A Airloads rotor, a shake test was completed on the Large Rotor Test Apparatus. The goal of the shake test was to characterize the oscillatory response of the test rig and provide a dynamic calibration of the balance to accurately measure vibratory hub loads. This paper provides a summary of the shake test results, including balance, shaft bending gauge, and accelerometer measurements. Sensitivity to hub mass and angle of attack were investigated during the shake test. Hub mass was found to have an important impact on the vibratory forces and moments measured at the balance, especially near the UH-60A 4/rev frequency. Comparisons were made between the accelerometer data and an existing finite-element model, showing agreement on mode shapes, but not on natural frequencies. Finally, the results of a simple dynamic calibration are presented, showing the effects of changes in hub mass. The results show that the shake test data can be used to correct in-plane loads measurements up to 10 Hz and normal loads up to 30 Hz.

  15. 锂/二氧化硫电池比热容的测量与分析%Test and Analysis of the Specific Heat Capacity of Lithium/Sulfur Dioxide Battery

    Institute of Scientific and Technical Information of China (English)

    白清源; 张兴娟; 杨春信

    2011-01-01

    Lithium/sulfur dioxide(Li-SO2) single cell usually presents as battery pack in practical application.Because the temperature caused by self-heating of the battery pack during discharging process is very high,specific thermal design is required.As one of the important thermodynamics parameters,specific heat capacity of battery is usually obtained by test.Based on preliminary studies,improvement is made in the following three aspects in this paper: transformer oil is employed for cooling,the test equipment of nylon material is designed for insulation,the thermal loss of the test devices is determined through brass test.Tests of specific heat capacity based on Li-SO2 battery conducted before and after discharging are carried out.The results show that the scheme is feasible and reasonable;it has the features of high accuracy and easy implement.Specific heat capacity of the battery will change after discharging,which should be considered in thermal design.%锂/二氧化硫(Li-SO2)单体电池在实际应用中多以电池组形式存在,当电池组工作时会因自身发热引起温度过高,因此需要对电池组进行热设计。比热容作为重要的热物性参数之一,通常由试验获得。文中在前期研究基础上,在3个方面进行了改进:采用变压器油为冷却工质;设计尼龙材料容器用于系统保温;通过黄铜确定试验装置的散热损失。针对未放电及2种放电时间后的Li-SO2单体电池进行了比热容测试。试验结果表明:该方案合理可行,具有测量精度高、易于实现的特点;电池放电后比热容会发生变化,应在热设计中给予考虑。

  16. School results and access test results as indicators of first-year performance at university

    Directory of Open Access Journals (Sweden)

    A Bothma

    2004-06-01

    Full Text Available The goals set by the National Plan for Higher Education, the fact that many schools are still severely disadvantaged as well as far-reaching changes in the school system demand that South African universities urgently reconsider their admission procedures. Redesigning admission procedures calls for a thorough understanding of the interrelationships between school marks, results in existing access tests and first-year university performance. These interrelationships were statistically investigated in the case of the 1999, 2000 and 2001 intake groups, who were compelled to write access tests before being admitted to Stellenbosch University. The results of this investigation confirm an alarming degree of unpreparedness among many prospective students regarding what is expected of them at university. This is aggravated by school marks creating a totally unrealistic expectation of performance in the first year at university. It is emphasised that schools and authorities dealing with admission of prospective students at universities should be cognisant of the findings reported here. Furthermore, the statistical analyses demonstrate several novel techniques for investigating the interrelationship between school marks, access test results and university performance.

  17. Results of the mole penetration tests in different materials

    Science.gov (United States)

    Wawrzaszek, Roman; Seweryn, Karol; Grygorczuk, Jerzy; Banaszkiewicz, Marek; Rybus, Tomasz; Wisniewski, Lukasz; Neal, Clive R.; Huang, Shaopeng

    2010-05-01

    . Influence of the material compaction on the mole progress was also investigated. For these tests the small testbed has been used. It allowed us to test our mole penetrator up to the depth of 0.5 meters. Obtained results show that 'KRET' is able to penetrate even compacted lunar regolith simulant CHENOBI with minimum progress rate about 2mm per stroke. Moreover, we have confirmed that the mole works properly in both materials with low and high cohesion.

  18. Rechargeable Battery Capacity Level Indicator

    OpenAIRE

    Ongere, Jared

    2015-01-01

    Technology on rechargeable batteries has advanced over the years as a result of the need to power portable devices that have risen in numbers in the last decade. Just like primary cells, rechargeable batteries work in the same way, only their chemical reactions are reversible. This project aimed at building a system that would indicate the capacity level of a Nickel Metal Hydride battery upon charging and discharging. The Nickel Metal Hydride battery was selected in this project due to it...

  19. Structure improvement and electrochemical studies of bipolar nickel metal hydride batteries for hybrid electric vehicles

    Institute of Scientific and Technical Information of China (English)

    DENG Chao; SHI Peng-fei

    2006-01-01

    Nickel metal hydride battery in bipolar design offers some advantages for its application as a power storage system for electric and hybrid vehicles. This paper deals with the structure design and electrochemical studies of bipolar Ni/MH batteries for hybrid vehicles. An improvement is applied in bipolar battery design,and such bipolar Ni/MH batteries with 5 sub-cells have been assembled and investigated. Testing results show that bipolar batteries with improved structure have better compression tolerance and cycle performance than conventional ones. In addition, the improved bipolar batteries display excellent large current discharge ability and high power density. As simulating working conditions for hybrid vehicles, the batteries show good stability during pulse cycles, which verifies the possibility of being used as a power storage device on hybrid vehicles.

  20. Paintable Battery

    OpenAIRE

    Singh, Neelam; Galande, Charudatta; Miranda, Andrea; Mathkar, Akshay; Gao, Wei; Reddy, Arava Leela Mohana; Vlad, Alexandru; Ajayan, Pulickel M.

    2012-01-01

    If the components of a battery, including electrodes, separator, electrolyte and the current collectors can be designed as paints and applied sequentially to build a complete battery, on any arbitrary surface, it would have significant impact on the design, implementation and integration of energy storage devices. Here, we establish a paradigm change in battery assembly by fabricating rechargeable Li-ion batteries solely by multi-step spray painting of its components on a variety of materials...