WorldWideScience

Sample records for baseline repeated measures

  1. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  2. Baseline and annual repeat rounds of screening. Implications for optimal regimens of screening

    Energy Technology Data Exchange (ETDEWEB)

    Henschke, Claudia I.; Salvatore, Mary; Cham, Matthew; Eber, Corey; Yip, Rowena; Yankelevitz, David F. [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Powell, Charles A.; DiFabrizio, Larry [Icahn School of Medicine at Mount Sinai, Department of Medicine, New York, NY (United States); Flores, Raja; Kaufman, Andrew [Icahn School of Medicine at Mount Sinai, Department of Thoracic Surgery, New York, NY (United States); Collaboration: International Early Lung Cancer Action Program Investigators

    2018-03-15

    Differences in results of baseline and subsequent annual repeat rounds provide important information for optimising the regimen of screening. A prospective cohort study of 65,374 was reviewed to examine the frequency/percentages of the largest noncalcified nodule (NCN), lung cancer cell types and Kaplan-Meier (K-M) survival rates, separately for baseline and annual rounds. Of 65,374 baseline screenings, NCNs were identified in 28,279 (43.3%); lung cancer in 737 (1.1%). Of 74,482 annual repeat screenings, new NCNs were identified in 4959 (7%); lung cancer in 179 (0.24%). Only adenocarcinoma was diagnosed in subsolid NCNs. Percentages of lung cancers by cell type were significantly different (p < 0.0001) in the baseline round compared with annual rounds, reflecting length bias, as were the ratios, reflecting lead times. Long-term K-M survival rate was 100% for typical carcinoids and for adenocarcinomas manifesting as subsolid NCNs; 85% (95% CI 81-89%) for adenocarcinoma, 74% (95% CI 63-85%) for squamous cell, 48% (95% CI 34-62%) for small cell. The rank ordering by lead time was the same as the rank ordering by survival rates. The significant differences in the frequency of NCNs and frequency and aggressiveness of diagnosed cancers in baseline and annual repeat need to be recognised for an optimal regimen of screening. (orig.)

  3. CT screening for lung cancer: Frequency of enlarged adrenal glands identified in baseline and annual repeat rounds

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Minxia [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Capital Medical University, Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Beijing (China); Yip, Rowena; Yankelevitz, David Y.; Henschke, Claudia I. [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States)

    2016-12-15

    To determine the frequency of adrenal enlargement of participants in a CT-screening program for lung cancer and demonstrate the progression during follow-up, separately for baseline and annual repeat rounds. HIPAA-compliant informed consent was obtained in 4,776 participants. The adrenal gland was defined as enlarged if it measured ≥6 mm at its largest diameter. Logistic regression analyses were performed. At baseline, 202 (4 %) of 4,776 participants had adrenal enlargement. Significant factors were age (OR = 1.4, 95 % CI: 1.2-1.7) and current smoker (OR = 1.8, 95 % CI: 1.3-2.4). Follow-up 7-18 months after baseline for 133 cases with adrenal enlargement <40 mm showed it decreased or was stable in 85 (64 %), and increased by <10 mm in 48 (36 %). Five (0.04 %) cases of adrenal enlargement were newly identified, none increased beyond 40 mm on follow-up. Adrenal enlargement was a significant predictor of a subsequent diagnosis of lung cancer (OR = 2.0, 95 % CI: 1.2-3.4). Participants with adrenal enlargement <40 mm identified at baseline and on repeat screening could be reasonably assessed on subsequent annual screening. Adrenal enlargement increased with increasing pack-years of smoking. Adrenal enlargement was an independent predictor of a subsequent diagnosis of lung cancer. (orig.)

  4. Repeatability of visual acuity measurement.

    Science.gov (United States)

    Raasch, T W; Bailey, I L; Bullimore, M A

    1998-05-01

    This study investigates features of visual acuity chart design and acuity testing scoring methods which affect the validity and repeatability of visual acuity measurements. Visual acuity was measured using the Sloan and British Standard letter series, and Landolt rings. Identifiability of the different letters as a function of size was estimated, and expressed in the form of frequency-of-seeing curves. These functions were then used to simulate acuity measurements with a variety of chart designs and scoring criteria. Systematic relationships exist between chart design parameters and acuity score, and acuity score repeatability. In particular, an important feature of a chart, that largely determines the repeatability of visual acuity measurement, is the amount of size change attributed to each letter. The methods used to score visual acuity performance also affect repeatability. It is possible to evaluate acuity score validity and repeatability using the statistical principles discussed here.

  5. Baseline repeated measures from controlled human exposure studies: associations between ambient air pollution exposure and the systemic inflammatory biomarkers IL-6 and fibrinogen.

    Science.gov (United States)

    Thompson, Aaron M S; Zanobetti, Antonella; Silverman, Frances; Schwartz, Joel; Coull, Brent; Urch, Bruce; Speck, Mary; Brook, Jeffrey R; Manno, Michael; Gold, Diane R

    2010-01-01

    Systemic inflammation may be one of the mechanisms mediating the association between ambient air pollution and cardiovascular morbidity and mortality. Interleukin-6 (IL-6) and fibrinogen are biomarkers of systemic inflammation that are independent risk factors for cardio-vascular disease. We investigated the association between ambient air pollution and systemic inflammation using baseline measurements of IL-6 and fibrinogen from controlled human exposure studies. In this retrospective analysis we used repeated-measures data in 45 nonsmoking subjects. Hourly and daily moving averages were calculated for ozone, nitrogen dioxide, sulfur dioxide, and particulate matter pollutants on systemic IL-6 and fibrinogen. Effect modification by season was considered. We observed a positive association between IL-6 and O3 [0.31 SD per O3 interquartile range (IQR); 95% confidence interval (CI), 0.080.54] and between IL-6 and SO2 (0.25 SD per SO2 IQR; 95% CI, 0.060.43). We observed the strongest effects using 4-day moving averages. Responses to pollutants varied by season and tended to be higher in the summer, particularly for O3 and PM2.5. Fibrinogen was not associated with pollution. This study demonstrates a significant association between ambient pollutant levels and baseline levels of systemic IL-6. These findings have potential implications for controlled human exposure studies. Future research should consider whether ambient pollution exposure before chamber exposure modifies IL-6 response.

  6. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  7. The Queensland study of Melanoma: Environmental and Genetic Associations (Q-MEGA). Study design, baseline characteristics, and repeatability of phenotype and sun exposure measures

    Science.gov (United States)

    Baxter, Amanda J.; Hughes, Maria Celia; Kvaskoff, Marina; Siskind, Victor; Shekar, Sri; Aitken, Joanne F.; Green, Adele C.; Duffy, David L.; Hayward, Nicholas K.; Martin, Nicholas G.; Whiteman, David C.

    2013-01-01

    Cutaneous malignant melanoma (CMM) is a major health issue in Queensland, Australia which has the world’s highest incidence. Recent molecular and epidemiologic studies suggest that CMM arises through multiple etiological pathways involving gene-environment interactions. Understanding the potential mechanisms leading to CMM requires larger studies than those previously conducted. This article describes the design and baseline characteristics of Q-MEGA, the Queensland study of Melanoma: Environmental and Genetic Associations, which followed-up four population-based samples of CMM patients in Queensland, including children, adolescents, men aged over 50, and a large sample of adult cases and their families, including twins. Q-MEGA aims to investigate the roles of genetic and environmental factors, and their interaction, in the etiology of melanoma. 3,471 participants took part in the follow-up study and were administered a computer-assisted telephone interview in 2002–2005. Updated data on environmental and phenotypic risk factors, and 2,777 blood samples were collected from interviewed participants as well as a subset of relatives. This study provides a large and well-described population-based sample of CMM cases with follow-up data. Characteristics of the cases and repeatability of sun exposure and phenotype measures between the baseline and the follow-up surveys, from six to 17 years later, are also described. PMID:18361720

  8. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.; Maity, A.; Mammen, E.; Yu, K.

    2009-01-01

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements

  9. Performance Measurement Baseline Change Request

    Data.gov (United States)

    Social Security Administration — The Performance Measurement Baseline Change Request template is used to document changes to scope, cost, schedule, or operational performance metrics for SSA's Major...

  10. On balanced minimal repeated measurements designs

    Directory of Open Access Journals (Sweden)

    Shakeel Ahmad Mir

    2014-10-01

    Full Text Available Repeated Measurements designs are concerned with scientific experiments in which each experimental unit is assigned more than once to a treatment either different or identical. This class of designs has the property that the unbiased estimators for elementary contrasts among direct and residual effects are obtainable. Afsarinejad (1983 provided a method of constructing balanced Minimal Repeated Measurements designs p < t , when t is an odd or prime power, one or more than one treatment may occur more than once in some sequences and  designs so constructed no longer remain uniform in periods. In this paper an attempt has been made to provide a new method to overcome this drawback. Specifically, two cases have been considered                RM[t,n=t(t-t/(p-1,p], λ2=1 for balanced minimal repeated measurements designs and  RM[t,n=2t(t-t/(p-1,p], λ2=2 for balanced  repeated measurements designs. In addition , a method has been provided for constructing              extra-balanced minimal designs for special case RM[t,n=t2/(p-1,p], λ2=1.

  11. Validity and repeatability of inertial measurement units for measuring gait parameters.

    Science.gov (United States)

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Methods for analysing cardiovascular studies with repeated measures

    NARCIS (Netherlands)

    Cleophas, T. J.; Zwinderman, A. H.; van Ouwerkerk, B. M.

    2009-01-01

    Background. Repeated measurements in a single subject are generally more similar than unrepeated measurements in different subjects. Unrepeated analyses of repeated data cause underestimation of the treatment effects. Objective. To review methods adequate for the analysis of cardiovascular studies

  13. Intra-examiner repeatability and agreement in accommodative response measurements.

    Science.gov (United States)

    Antona, B; Sanchez, I; Barrio, A; Barra, F; Gonzalez, E

    2009-11-01

    Clinical measurement of the accommodative response (AR) identifies the focusing plane of a subject with respect to the accommodative target. To establish whether a significant change in AR has occurred, it is important to determine the repeatability of this measurement. This study had two aims: First, to determine the intraexaminer repeatability of AR measurements using four clinical methods: Nott retinoscopy, monocular estimate method (MEM) retinoscopy, binocular crossed cylinder test (BCC) and near autorefractometry. Second, to study the level of agreement between AR measurements obtained with the different methods. The AR of the right eye at one accommodative demand of 2.50 D (40 cm) was measured on two separate occasions in 61 visually normal subjects of mean age 19.7 years (range 18-32 years). The intraexaminer repeatability of the tests, and agreement between them, were estimated by the Bland-Altman method. We determined mean differences (MD) and the 95% limits of agreement [coefficient of repeatability (COR) and coefficient of agreement (COA)]. Nott retinoscopy and BCC offered the best repeatability, showing the lowest MD and narrowest 95% interval of agreement (Nott: -0.10 +/- 0.66 D, BCC: -0.05 +/- 0.75 D). The 95% limits of agreement for the four techniques were similar (COA = +/- 0.92 to +/-1.00 D) yet clinically significant, according to the expected values of the AR. The two dynamic retinoscopy techniques (Nott and MEM) had a better agreement (COA = +/-0.64 D) although this COA must be interpreted in the context of the low MEM repeatability (COR = +/-0.98 D). The best method of assessing AR was Nott retinoscopy. The BCC technique was also repeatable, and both are recommended as suitable methods for clinical use. Despite better agreement between MEM and Nott, agreement among the remaining methods was poor such that their interchangeable use in clinical practice is not recommended.

  14. Analysis of antenna position measurements and weather station network data during the ALMA long baseline campaign of 2015

    Science.gov (United States)

    Hunter, Todd R.; Lucas, Robert; Broguière, Dominique; Fomalont, Ed B.; Dent, William R. F.; Phillips, Neil; Rabanus, David; Vlahakis, Catherine

    2016-07-01

    In a radio interferometer, the geometrical antenna positions are determined from measurements of the observed delay to each antenna from observations across the sky of many point sources whose positions are known to high accuracy. The determination of accurate antenna positions relies on accurate calibration of the dry and wet delay of the atmosphere above each antenna. For the Atacama Large Millimeter/Submillimeter Array (ALMA), with baseline lengths up to 15 kilometers, the geography of the site forces the height above mean sea level of the more distant antenna pads to be significantly lower than the central array. Thus, both the ground level meteorological values and the total water column can be quite different between antennas in the extended configurations. During 2015, a network of six additional weather stations was installed to monitor pressure, temperature, relative humidity and wind velocity, in order to test whether inclusion of these parameters could improve the repeatability of antenna position determinations in these configurations. We present an analysis of the data obtained during the ALMA Long Baseline Campaign of October through November 2015. The repeatability of antenna position measurements typically degrades as a function of antenna distance. Also, the scatter is more than three times worse in the vertical direction than in the local tangent plane, suggesting that a systematic effect is limiting the measurements. So far we have explored correcting the delay model for deviations from hydrostatic equilibrium in the measured air pressure and separating the partial pressure of water from the total pressure using water vapor radiometer (WVR) data. Correcting for these combined effects still does not provide a good match to the residual position errors in the vertical direction. One hypothesis is that the current model of water vapor may be too simple to fully remove the day-to-day variations in the wet delay. We describe possible new avenues of

  15. Measuring Repeatability of the Focus-variable Lenses

    Directory of Open Access Journals (Sweden)

    Jan Řezníček

    2014-12-01

    Full Text Available In the field of photogrammetry, the optical system, usually represented by the glass lens, is used for metric purposes. Therefore, the aberration characteristics of such a lens, inducing deviations from projective imaging, has to be well known. However, the most important property of the metric lens is the stability of its glass and mechanical elements, ensuring long-term reliability of the measured parameters. In case of a focus-variable lens, the repeatability of the lens setup is important as well. Lenses with a fixed focal length are usually considered as “fixed” though, in fact, most of them contain one or more movable glass elements, providing the focusing function. In cases where the lens is not equipped with fixing screws, the repeatability of the calibration parameters should be known. This paper derives simple mathematical formulas that can be used for measuring the repeatability of the focus-variable lenses, and gives a demonstrative example of such measuring. The given procedure has the advantage that only demanded parameters are estimated, hence, no unwanted correlations with the additional parameters exist. The test arrangement enables us to measure each demanded magnification of the optical system, which is important in close-range photogrammetry.

  16. On model selections for repeated measurement data in clinical studies.

    Science.gov (United States)

    Zou, Baiming; Jin, Bo; Koch, Gary G; Zhou, Haibo; Borst, Stephen E; Menon, Sandeep; Shuster, Jonathan J

    2015-05-10

    Repeated measurement designs have been widely used in various randomized controlled trials for evaluating long-term intervention efficacies. For some clinical trials, the primary research question is how to compare two treatments at a fixed time, using a t-test. Although simple, robust, and convenient, this type of analysis fails to utilize a large amount of collected information. Alternatively, the mixed-effects model is commonly used for repeated measurement data. It models all available data jointly and allows explicit assessment of the overall treatment effects across the entire time spectrum. In this paper, we propose an analytic strategy for longitudinal clinical trial data where the mixed-effects model is coupled with a model selection scheme. The proposed test statistics not only make full use of all available data but also utilize the information from the optimal model deemed for the data. The performance of the proposed method under various setups, including different data missing mechanisms, is evaluated via extensive Monte Carlo simulations. Our numerical results demonstrate that the proposed analytic procedure is more powerful than the t-test when the primary interest is to test for the treatment effect at the last time point. Simulations also reveal that the proposed method outperforms the usual mixed-effects model for testing the overall treatment effects across time. In addition, the proposed framework is more robust and flexible in dealing with missing data compared with several competing methods. The utility of the proposed method is demonstrated by analyzing a clinical trial on the cognitive effect of testosterone in geriatric men with low baseline testosterone levels. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.

    2009-05-20

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements. We allow for a working covariance matrix for the regression errors, showing that our method is most efficient when the correct covariance matrix is used. The component functions achieve the known asymptotic variance lower bound for the scalar argument case. Smooth backfitting also leads directly to design-independent biases in the local linear case. Simulations show our estimator has smaller variance than the usual kernel estimator. This is also illustrated by an example from nutritional epidemiology. © 2009 Biometrika Trust.

  18. [Analysis of variance of repeated data measured by water maze with SPSS].

    Science.gov (United States)

    Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang

    2007-01-01

    To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (PSPSS statistical package is available to fulfil this process.

  19. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Directory of Open Access Journals (Sweden)

    Aysun Şanal Doğan

    2018-04-01

    Full Text Available Objectives: The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Materials and Methods: Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy. Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Results: Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198 and gender (M/F: 4/29 vs. 8/32, p=0.366. Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90. Conclusion: The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  20. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Science.gov (United States)

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  1. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    DEFF Research Database (Denmark)

    Axén, Iben; Bodin, Lennart; Kongsted, Alice

    2012-01-01

    to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor) variables? This question was answered using generalized...... involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview...... for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. METHODS: A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions...

  2. Theoretical repeatability assessment without repetitive measurements in gradient high-performance liquid chromatography.

    Science.gov (United States)

    Kotani, Akira; Tsutsumi, Risa; Shoji, Asaki; Hayashi, Yuzuru; Kusu, Fumiyo; Yamamoto, Kazuhiro; Hakamata, Hideki

    2016-07-08

    This paper puts forward a time and material-saving method for evaluating the repeatability of area measurements in gradient HPLC with UV detection (HPLC-UV), based on the function of mutual information (FUMI) theory which can theoretically provide the measurement standard deviation (SD) and detection limits through the stochastic properties of baseline noise with no recourse to repetitive measurements of real samples. The chromatographic determination of terbinafine hydrochloride and enalapril maleate is taken as an example. The best choice of the number of noise data points, inevitable for the theoretical evaluation, is shown to be 512 data points (10.24s at 50 point/s sampling rate of an A/D converter). Coupled with the relative SD (RSD) of sample injection variability in the instrument used, the theoretical evaluation is proved to give identical values of area measurement RSDs to those estimated by the usual repetitive method (n=6) over a wide concentration range of the analytes within the 95% confidence intervals of the latter RSD. The FUMI theory is not a statistical one, but the "statistical" reliability of its SD estimates (n=1) is observed to be as high as that attained by thirty-one measurements of the same samples (n=31). Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Education for patients with chronic kidney disease in Taiwan: a prospective repeated measures study.

    Science.gov (United States)

    Yen, Miaofen; Huang, Jeng-Jong; Teng, Hsiu-Lan

    2008-11-01

    To investigate the physical, knowledge and quality of life outcomes of an educational intervention for patients with early stage chronic kidney disease. A comprehensive predialysis education care team can be effective in slowing the progression of chronic kidney disease. A single group repeated measures design was used to evaluate the effects of the intervention. Participants were recruited through health department community health screen data banks. A predialysis, team-delivered educational intervention covering renal function health care, dietary management of renal function and the effects of Chinese herb medication on renal function was designed and implemented. Data were collected at baseline, six and 12 months. Study outcomes included physical indicators, knowledge (renal function protection, use of Chinese herbs and renal function and diet) and quality of life. Data were analysed using repeated measure anova to test for change over time in outcome variables. Sixty-six persons participated in this study. The predialysis educational intervention showed significant differences at the three time points in overall knowledge scores, waist-hip ratio, body mass index and global health status. Knowledge measures increased at month 6 and decreased at month 12. The primary indicator of renal function, glomerular filtration rate, remained stable throughout the 12 months of follow-up, despite the relatively older mean age of study participants. A predialysis education care team can provide effective disease-specific knowledge and may help retard deterioration of renal function in persons with early-stage chronic kidney disease. The intervention dose may need to be repeated every six months to maintain knowledge effects. A predialysis educational program with disease-specific knowledge and information is feasible and may provide positive outcomes for patients. Topics on the uses of Chinese herbs should be included for people who are likely to use alternative therapies.

  4. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  5. The effect of repeated applanation on subsequent IOP measurements.

    Science.gov (United States)

    AlMubrad, Turki M; Ogbuehi, Kelechi C

    2008-11-01

    In studies aimed at assessing the accuracy and repeatability of non-contact tonometers, the order in which these tonometers and the Goldmann tonometer are used is usually randomised despite studies in the literature that demonstrate an ocular massage effect that occurs post-applanation but not after non-contact tonometry. The purpose of this study was to investigate the effect of repeated corneal applanation on subsequent assessments of IOP. Data were obtained from 65 left eyes of 65 young, oculovisual normals. Three sets of IOP measurements were obtained, one set with the Goldmann applanation tonometer and two with the Topcon CT80 non-contact tonometer (one set each before and after applanation with the Goldmann tonometer), in each one of two separate measurement sessions, one week apart. The average (and SD) IOP measured with the Goldmann tonometer in the first session (14.8+/-2.9 mmHg) did not vary significantly from the IOP measured with the non-contact tonometer (pre-applanation) in both sessions or with the average Goldmann IOP in the second session. The bias (mean difference +/- SD) between methods was 0.3+/-1.4 mmHg and 0.4+/-1.4 mmHg, respectively, for the first and second sessions, with the CT80 (pre-applanation) recording the higher IOP in both sessions. The within-session repeatability coefficients were +/-2.3 mmHg, +/-2.6 mmHg, +/-2.1 mmHg and +/-2.0 mmHg for the CT80 (pre-applanation) in the first and second sessions, and the Goldmann tonometer in the first and second sessions, respectively. Test-retest repeatability coefficients were +/-2.8 mmHg and +/-2.5 mmHg for the CT80 (pre-applanation) and the Goldmann tonometer respectively. Post-applanation with the Goldmann tonometer, there was a statistically significant (pcontact tonometer in both sessions. These results suggest that repeated corneal applanation leads to a statistically significant reduction in IOP on subsequent measurements.

  6. Baseline Radioactivity Measurements In The Vicinity Of A Gold ...

    African Journals Online (AJOL)

    Western Region, Ghana) to obtain baseline radioactivity data prior to the installation of Cs-137 nuclear density gauges for quality control measure-ment of the density of slurry in the pipelines at the plant. A survey meter, gamma spectrometry and ...

  7. Repeatability of Lucas chamber measurements; Powtarzalnosc pomiarow za pomoca komory Lucasa

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B.

    1997-12-31

    Results of investigations concerning the repeatability of the measurements carried out with Lucas chamber are presented in the report. The Lucas chamber is used for determination of radon concentration in air, and the Lucas chamber itself is measured in a laboratory stand. The repeatability of measurements is {+-}5.4% relative. The error due to instability of measuring channel gain is estimated to be 2-3% relative. (author). 5 refs, 17 figs, 5 tabs.

  8. Alcohol intake and colorectal cancer: a comparison of approaches for including repeated measures of alcohol consumption

    DEFF Research Database (Denmark)

    Thygesen, Lau Caspar; Wu, Kana; Grønbaek, Morten

    2008-01-01

    BACKGROUND: In numerous studies, alcohol intake has been found to be positively associated with colorectal cancer risk. However, the majority of studies included only one exposure measurement, which may bias the results if long-term intake is relevant.METHODS: We compared different approaches...... for including repeated measures of alcohol intake among 47,432 US men enrolled in the Health Professionals Follow-up Study. Questionnaires including questions on alcohol intake had been completed in 1986, 1990, 1994, and 1998. The outcome was incident colorectal cancer during follow-up from 1986 to 2002.RESULTS......: During follow-up, 868 members of the cohort experienced colorectal cancer. Baseline, updated, and cumulative average alcohol intakes were positively associated with colorectal cancer, with only minor differences among the approaches. These results support moderately increased risk for intake >30 g...

  9. Safety of Repeated Yttrium-90 Radioembolization

    International Nuclear Information System (INIS)

    Lam, Marnix G. E. H.; Louie, John D.; Iagaru, Andrei H.; Goris, Michael L.; Sze, Daniel Y.

    2013-01-01

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver’s cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51–71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction

  10. Safety of Repeated Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Marnix G. E. H.; Louie, John D. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Iagaru, Andrei H.; Goris, Michael L. [Stanford University School of Medicine, Division of Nuclear Medicine (United States); Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-10-15

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver's cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51-71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction.

  11. Repeated thermal stressor causes chronic elevation of baseline corticosterone and suppresses the physiological endocrine sensitivity to acute stressor in the cane toad (Rhinella marina).

    Science.gov (United States)

    Narayan, Edward J; Hero, Jean-Marc

    2014-04-01

    Extreme environmental temperature could impact the physiology and ecology of animals. The stress endocrine axis provides necessary physiological stress response to acute (day-day) stressors. Presently, there are no empirical evidences showing that exposure to extreme thermal stressor could cause chronic stress in amphibians. This could also modulate the physiological endocrine sensitivity to acute stressors and have serious implications for stress coping in amphibians, particularly those living in fragmented and disease prone environments. We addressed this important question using the cane toad (Rhinella marina) model from its introduced range in Queensland, Australia. We quantified their physiological endocrine sensitivity to a standard acute (capture and handling) stressor after exposing the cane toads to thermal shock at 35°C for 30min daily for 34 days. Corticosterone (CORT) responses to the capture and handling protocol were measured on three sampling intervals (days 14, 24, and 34) to determine whether the physiological endocrine sensitivity was maintained or modulated over-time. Two control groups (C1 for baseline CORT measurement only and C2 acute handled only) and two temperature treatment groups (T1 received daily thermal shock up to day 14 only and a recovery phase of 20 days and T2 received thermal shock daily for 34 days). Results showed that baseline CORT levels remained high on day 14 (combined effect of capture, captivity and thermal stress) for both T1 and T2. Furthermore, baseline CORT levels decreased for T1 once the thermal shock was removed after day 14 and returned to baseline by day 29. On the contrary, baseline CORT levels kept on increasing for T2 over the 34 days of daily thermal shocks. Furthermore, the magnitudes of the acute CORT responses or physiological endocrine sensitivity were consistently high for both C1 and T1. However, acute CORT responses for T2 toads were dramatically reduced between days 24 and 34. These novel findings

  12. Repeated measures of body mass index and C-reactive protein in relation to all-cause mortality and cardiovascular disease

    DEFF Research Database (Denmark)

    O'Doherty, Mark G; Jørgensen, Torben; Borglykke, Anders

    2014-01-01

    Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single 'baseline' measurement and such analyses cannot account for possible changes in these which...... may lead to a biased estimation of risk. Using four cohorts from CHANCES which had repeated measures in participants 50 years and older, multivariate time-dependent Cox proportional hazards was used to estimate hazard ratios (HR) and 95 % confidence intervals (CI) to examine the relationship between......, they may participate in distinct/independent pathways. Accounting for independent changes in risk factors over time may be crucial for unveiling their effects on mortality and disease morbidity....

  13. [Analysis of binary classification repeated measurement data with GEE and GLMMs using SPSS software].

    Science.gov (United States)

    An, Shengli; Zhang, Yanhong; Chen, Zheng

    2012-12-01

    To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.

  14. High precision measurement of the micro-imaging system to check repeatability of precision

    International Nuclear Information System (INIS)

    Cheng Lin; Song Li; Ma Chuntao; Luo Hongxin; Wang Jie

    2010-01-01

    The beamlines slits of Shanghai Synchrotron Radiation Facility (SSRF) are required to have a repeatability of better than 1 μm. Before the slits installation, the off-line and/or on-line repeatability measurements must be conducted. A machine vision measuring system based on high resolution CCD and adjustable high magnification lens was used in this regard. A multi-level filtering method was used to treat the imaging data. After image binarization, the imaging noises were depressed effectively by using of algebraic mean filtering, statistics median filtering,and the least square filtering. Using the subtracted image between the images before and after slit movement, an average displacement of slit blades could be obtained, and the repeatability of slit could be measured, with a resolution of 0.3 μm of the measurement system. The experimental results show that this measurement system meets the requirements for non-contact measurements to the repeatability of slits. (authors)

  15. Measuring cognitive change with ImPACT: the aggregate baseline approach.

    Science.gov (United States)

    Bruce, Jared M; Echemendia, Ruben J; Meeuwisse, Willem; Hutchison, Michael G; Aubry, Mark; Comper, Paul

    2017-11-01

    The Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) is commonly used to assess baseline and post-injury cognition among athletes in North America. Despite this, several studies have questioned the reliability of ImPACT when given at intervals employed in clinical practice. Poor test-retest reliability reduces test sensitivity to cognitive decline, increasing the likelihood that concussed athletes will be returned to play prematurely. We recently showed that the reliability of ImPACT can be increased when using a new composite structure and the aggregate of two baselines to predict subsequent performance. The purpose of the present study was to confirm our previous findings and determine whether the addition of a third baseline would further increase the test-retest reliability of ImPACT. Data from 97 English speaking professional hockey players who had received at least 4 ImPACT baseline evaluations were extracted from a National Hockey League Concussion Program database. Linear regression was used to determine whether each of the first three testing sessions accounted for unique variance in the fourth testing session. Results confirmed that the aggregate baseline approach improves the psychometric properties of ImPACT, with most indices demonstrating adequate or better test-retest reliability for clinical use. The aggregate baseline approach provides a modest clinical benefit when recent baselines are available - and a more substantial benefit when compared to approaches that obtain baseline measures only once during the course of a multi-year playing career. Pending confirmation in diverse samples, neuropsychologists are encouraged to use the aggregate baseline approach to best quantify cognitive change following sports concussion.

  16. Establishing baseline water quality for household wells within the Marcellus Shale gas region, Susquehanna County, Pennsylvania, U.S.A

    International Nuclear Information System (INIS)

    Rhodes, Amy L.; Horton, Nicholas J.

    2015-01-01

    Highlights: • Laws do not specify how baseline tests are conducted prior to hydraulic fracturing. • Study estimates variability of groundwater chemistry for repeated measurements. • Water chemistry varies more geographically than at a single, household well. • A single, certified test can characterize baseline geochemistry of groundwater. • Multiple measurements better estimate upper limits of regional baseline values. - Abstract: Flowback fluids associated with hydraulic fracturing shale gas extraction are a potential source of contamination for shallow aquifers. In the Marcellus Shale region of northeastern Pennsylvania, certified water tests have been used to establish baseline water chemistry of private drinking water wells. This study investigates whether a single, certified multiparameter water test is sufficient for establishing baseline water chemistry from which possible future contamination by flowback waters could be reliably recognized. We analyzed the water chemistry (major and minor inorganic elements and stable isotopic composition) of multiple samples collected from lake, spring, and well water from 35 houses around Fiddle Lake, Susquehanna County, PA that were collected over approximately a two-year period. Statistical models estimated variance of results within and between households and tested for significant differences between means of our repeated measurements and prior certified water tests. Overall, groundwater chemistry varies more spatially due to heterogeneity of minerals within the bedrock aquifer and due to varying inputs of road salt runoff from paved roads than it does temporally at a single location. For wells located within road salt-runoff zones, Na + and Cl − concentrations, although elevated, are generally consistent through repeated measurements. High acid neutralizing capacity (ANC) and base cation concentrations in well water sourced from mineral weathering reactions, and a uniform stable isotopic composition for

  17. Can father inclusive practice reduce paternal postnatal anxiety? A repeated measures cohort study using the hospital anxiety and depression scale

    Directory of Open Access Journals (Sweden)

    Tohotoa Jenny

    2012-07-01

    Full Text Available Abstract Background Perinatal research on anxiety and depression has primarily focused on mothers. We have limited knowledge of fathers’ anxiety during the perinatal period yet there is evidence that the parenting capacity of a person can be compromised by anxiety and depression. The purpose of this paper is to identify the impact of a father inclusive intervention on perinatal anxiety and depression. The prime focus of the intervention was to provide education and support to fathers of breastfeeding partners with the aim of increasing both initiation and duration of breastfeeding. Methods A repeated measures cohort study was conducted during a RCT that was implemented across eight public maternity hospitals in Perth, Western Australia between May 2008 and June 2009. A baseline questionnaire which included the Hospital Anxiety and Depression Scale (HADS was administered to all participants on the first night of their hospital based antenatal education program and was repeated at six weeks postnatal. SPSS version 17 was used for reporting descriptive results. Results The mean anxiety levels at baseline for the fathers in the intervention group (n=289 and control group (n=244 were 4.58 and 4.22 respectively. At 6 weeks postnatal (only matched pairs, intervention and control group were 3.93 and 3.79. More intervention group fathers self-rated less anxiety compared to the fathers in the control group from baseline to post test (p=0.048. Depression scores for intervention fathers at baseline (mean =1.09 and at six weeks (mean=1.09 were very similar to fathers in the control group at baseline (mean=1.11 and at six weeks (mean =1.07 with no significant changes. Conclusions Both intervention and control group fathers experienced some anxiety prior to the birth of their baby, but this was rapidly reduced at six weeks. Paternal anxiety is common to new fathers and providing them with information and strategies for problem-solving can increase their

  18. Contribution of BeiDou satellite system for long baseline GNSS measurement in Indonesia

    Science.gov (United States)

    Gumilar, I.; Bramanto, B.; Kuntjoro, W.; Abidin, H. Z.; Trihantoro, N. F.

    2018-05-01

    The demand for more precise positioning method using GNSS (Global Navigation Satellite System) in Indonesia continue to rise. The accuracy of GNSS positioning depends on the length of baseline and the distribution of observed satellites. BeiDou Navigation Satellite System (BDS) is a positioning system owned by China that operating in Asia-Pacific region, including Indonesia. This research aims to find out the contribution of BDS in increasing the accuracy of long baseline static positioning in Indonesia. The contributions are assessed by comparing the accuracy of measurement using only GPS (Global Positioning System) and measurement using the combination of GPS and BDS. The data used is 5 days of GPS and BDS measurement data for baseline with 120 km in length. The software used is open-source RTKLIB and commercial software Compass Solution. This research will explain in detail the contribution of BDS to the accuracy of position in long baseline static GNSS measurement.

  19. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    Science.gov (United States)

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  20. Predicting clinical concussion measures at baseline based on motivation and academic profile.

    Science.gov (United States)

    Trinidad, Katrina J; Schmidt, Julianne D; Register-Mihalik, Johna K; Groff, Diane; Goto, Shiho; Guskiewicz, Kevin M

    2013-11-01

    The purpose of this study was to predict baseline neurocognitive and postural control performance using a measure of motivation, high school grade point average (hsGPA), and Scholastic Aptitude Test (SAT) score. Cross-sectional. Clinical research center. Eighty-eight National Collegiate Athletic Association Division I incoming student-athletes (freshman and transfers). Participants completed baseline clinical concussion measures, including a neurocognitive test battery (CNS Vital Signs), a balance assessment [Sensory Organization Test (SOT)], and motivation testing (Rey Dot Counting). Participants granted permission to access hsGPA and SAT total score. Standard scores for each CNS Vital Signs domain and SOT composite score. Baseline motivation, hsGPA, and SAT explained a small percentage of the variance of complex attention (11%), processing speed (12%), and composite SOT score (20%). Motivation, hsGPA, and total SAT score do not explain a significant amount of the variance in neurocognitive and postural control measures but may still be valuable to consider when interpreting neurocognitive and postural control measures.

  1. Repeatability of Objective Measurements of Linear Udder and Body ...

    African Journals Online (AJOL)

    The objective of this study was to estimates the repeatability of objective measurements on linear udder and body conformation traits and to evaluate the objectivity of the measurements in Friesian x Bunaji cows. Data from 50 (F1) Frisian X Bunaji cows collected between 2007 and 2008 at the Dairy Research Farm of the ...

  2. A Network-Based Algorithm for Clustering Multivariate Repeated Measures Data

    Science.gov (United States)

    Koslovsky, Matthew; Arellano, John; Schaefer, Caroline; Feiveson, Alan; Young, Millennia; Lee, Stuart

    2017-01-01

    The National Aeronautics and Space Administration (NASA) Astronaut Corps is a unique occupational cohort for which vast amounts of measures data have been collected repeatedly in research or operational studies pre-, in-, and post-flight, as well as during multiple clinical care visits. In exploratory analyses aimed at generating hypotheses regarding physiological changes associated with spaceflight exposure, such as impaired vision, it is of interest to identify anomalies and trends across these expansive datasets. Multivariate clustering algorithms for repeated measures data may help parse the data to identify homogeneous groups of astronauts that have higher risks for a particular physiological change. However, available clustering methods may not be able to accommodate the complex data structures found in NASA data, since the methods often rely on strict model assumptions, require equally-spaced and balanced assessment times, cannot accommodate missing data or differing time scales across variables, and cannot process continuous and discrete data simultaneously. To fill this gap, we propose a network-based, multivariate clustering algorithm for repeated measures data that can be tailored to fit various research settings. Using simulated data, we demonstrate how our method can be used to identify patterns in complex data structures found in practice.

  3. Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

    Directory of Open Access Journals (Sweden)

    Mehmet Kola

    2014-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ. Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC. Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2 and reproducibility (ICC, 0.916-0.999 were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2 and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all. Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.

  4. High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices

    Science.gov (United States)

    Harrar, Solomon W.; Kong, Xiaoli

    2015-01-01

    In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results. PMID:26778861

  5. Atmospheric pressure loading parameters from very long baseline interferometry observations

    Science.gov (United States)

    Macmillan, D. S.; Gipson, John M.

    1994-01-01

    Atmospheric mass loading produces a primarily vertical displacement of the Earth's crust. This displacement is correlated with surface pressure and is large enough to be detected by very long baseline interferometry (VLBI) measurements. Using the measured surface pressure at VLBI stations, we have estimated the atmospheric loading term for each station location directly from VLBI data acquired from 1979 to 1992. Our estimates of the vertical sensitivity to change in pressure range from 0 to -0.6 mm/mbar depending on the station. These estimates agree with inverted barometer model calculations (Manabe et al., 1991; vanDam and Herring, 1994) of the vertical displacement sensitivity computed by convolving actual pressure distributions with loading Green's functions. The pressure sensitivity tends to be smaller for stations near the coast, which is consistent with the inverted barometer hypothesis. Applying this estimated pressure loading correction in standard VLBI geodetic analysis improves the repeatability of estimated lengths of 25 out of 37 baselines that were measured at least 50 times. In a root-sum-square (rss) sense, the improvement generally increases with baseline length at a rate of about 0.3 to 0.6 ppb depending on whether the baseline stations are close to the coast. For the 5998-km baseline from Westford, Massachusetts, to Wettzell, Germany, the rss improvement is about 3.6 mm out of 11.0 mm. The average rss reduction of the vertical scatter for inland stations ranges from 2.7 to 5.4 mm.

  6. Repeatability in Color Measurements of a Spectrophotometer using Different Positioning Devices.

    Science.gov (United States)

    Hemming, Michael; Kwon, So Ran; Qian, Fang

    2015-12-01

    This study aimed to evaluate the repeatability of color measurements of an intraoral spectrophotometer with the use of three different methods by two operators. A total of 60 teeth were obtained, comprising 30 human maxillary teeth [central incisors (n = 10); canines (n = 10); molars (n = 10)] and 30 artificial teeth [lateral incisors (n = 10); premolar (n = 20)]. Multiple repeated color measurements were obtained from each tooth using three measuring methods by each of the two operators. Five typodonts with alternating artificial and human teeth were made. Measurements were taken by two operators with the Vita EasyShade spectrophotometer using the custom tray (CT), custom jig (CJ) and free hand (FH) method, twice, at an interval of 2 to 7 days. Friedman test was used to detect difference among the three color measuring methods. Post hoc Wilcoxon signed-rank test with Bonferroni correction applied was used for pair-wise comparison of color measurements among the three methods. Additionally, a paired-sample t-test was used to assess a significant difference between the two duplicated measurements made on the same tooth by the same operator for each color parameter and measuring method. For operator A, mean (SD) overall color change-ΔE* (SD) perceived for FH, CT and CJ were 2.21(2.00), 2.39 (1.58) and 2.86 (1.92), respectively. There was statistically significant difference in perceived ΔE* in FH vs CJ (p = 0.0107). However, there were no significant differences between FH and CT (p = 0.2829) or between CT and CJ (p = 0.1159). For operator B mean ΔE* (SD) for FH, CT and CJ were 3.24 (3.46), 1.95 (1.19) and 2.45 (1.56), respectively. There was a significant difference between FH and CT (p = 0.0031). However, there were no statistically significant differences in ΔE* in FH vs CJ (p = 0.3696) or CT vs CJ (p = 0.0809). The repeatability of color measurements was different among the three measuring methods by operators. Overall, the CT method worked well for both

  7. Reject/repeat analysis and the effect prior film viewing has on a department's reject/repeat rate

    International Nuclear Information System (INIS)

    Clark, P.A.; Hogg, P.

    2003-01-01

    Purpose: Achieving cost-effectiveness within the NHS is an old initiative but one that has again been highlighted by recent government policies (The New NHS-Modern and Dependable, Stationary Office, London, 1997). It has been reiterated that it is the responsibility of individual Trusts to devise means to provide such a service. Reject/repeat analyses have long been the primary tool used to assess the cost-effectiveness of radiography departments (Quality Assurance in Diagnostic Radiology, WHO, Geneva, 1982). This research paper examines an in-house initiative (viewing patients' previous films) commonly employed in other Health Trusts in order to reduce departmental repeat/reject rates. Method: Three hundred orthopaedic patients with hip, knee and ankle prostheses were included in a reject/repeat analysis. The aim was to investigate whether or not viewing patient's previous relevant radiographs would be advantageous to the practicing radiographer. This was done through an audit cycle consisting of two audit periods each lasting for 3 months. The primary audit period recorded the baseline repeat/reject rate, with the secondary audit period recording the repeat/reject rate under an experimental condition of viewing the relevant radiographs. Results: The baseline audit revealed repeat rates of 33% in orthopaedic patients with hip, knee and ankle prostheses. The availability of prior film viewing to the radiographer reduced this repeat rate to 10.6%. Conclusion: Prior film viewing dramatically reduced the department's repeat/reject rate by 22.4%. This provides scope for significant patient dose reductions as well as reducing departmental film expenses. This is an underestimated initiative and should be used appropriately in routine clinical practice

  8. Maintaining confidentiality in prospective studies: anonymous repeated measurements via email (ARME) procedure.

    Science.gov (United States)

    Carli, Vladimir; Hadlaczky, Gergö; Wasserman, Camilla; Stingelin-Giles, Nicola; Reiter-Theil, Stella; Wasserman, Danuta

    2012-02-01

    Respecting and protecting the confidentiality of data and the privacy of individuals regarding the information that they have given as participants in a research project is a cornerstone of complying with accepted research standards. However, in longitudinal studies, establishing and maintaining privacy is often challenging because of the necessity of repeated contact with participants. A novel internet-based solution is introduced here, which maintains privacy while at the same time ensures linkage of data to individual participants in a repeated measures design. With the use of the anonymous repeated measurements via email (ARME) procedure, two separate one-way communication systems are established through ad hoc email accounts and a secure study website. Strengths and limitations of the approach are discussed.

  9. Accounting for baseline differences and measurement error in the analysis of change over time.

    Science.gov (United States)

    Braun, Julia; Held, Leonhard; Ledergerber, Bruno

    2014-01-15

    If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Repeatability of central corneal thickness measurement with the Pentacam HR system

    Directory of Open Access Journals (Sweden)

    Ruiz Simonato Alonso

    2012-02-01

    Full Text Available PURPOSE: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT given by the Pentacam High Resolution (HR Comprehensive Eye Scanner (Oculus, Wetzlar, Germany over time. METHODS: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm 3 to 12 months apart, and compared. RESULTS: One hundred and sixteen eyes (n=116 of 62 health patients were included in this study. Average CCT in first and last visits was 541.6±37 µm and 543.6±36.9 µm respectively. Mean difference between both measurements was 9.2±6.4 µm, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r² = 0,9209. CONCLUSION: Pentacam (HR CTm gives repeatable CCT measurements over time.

  11. Baseline Optimization for the Measurement of CP Violation, Mass Hierarchy, and $\\theta_{23}$ Octant in a Long-Baseline Neutrino Oscillation Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bass, M. [Colorado State U.; Bishai, M. [Brookhaven; Cherdack, D. [Colorado State U.; Diwan, M. [Brookhaven; Djurcic, Z. [Argonne; Hernandez, J. [Houston U.; Lundberg, B. [Fermilab; Paolone, V. [Pittsburgh U.; Qian, X. [Brookhaven; Rameika, R. [Fermilab; Whitehead, L. [Houston U.; Wilson, R. J. [Colorado State U.; Worcester, E. [Brookhaven; Zeller, G. [Fermilab

    2015-03-19

    Next-generation long-baseline electron neutrino appearance experiments will seek to discover CP violation, determine the mass hierarchy and resolve the θ23 octant. In light of the recent precision measurements of θ13, we consider the sensitivity of these measurements in a study to determine the optimal baseline, including practical considerations regarding beam and detector performance. We conclude that a detector at a baseline of at least 1000 km in a wide-band muon neutrino beam is the optimal configuration.

  12. Convergence of repeated quantum nondemolition measurements and wave-function collapse

    International Nuclear Information System (INIS)

    Bauer, Michel; Bernard, Denis

    2011-01-01

    Motivated by recent experiments on quantum trapped fields, we give a rigorous proof that repeated indirect quantum nondemolition (QND) measurements converge to the collapse of the wave function as predicted by the postulates of quantum mechanics for direct measurements. We also relate the rate of convergence toward the collapsed wave function to the relative entropy of each indirect measurement, a result which makes contact with information theory.

  13. The impact of sterile neutrinos on CP measurements at long baselines

    International Nuclear Information System (INIS)

    Gandhi, Raj; Kayser, Boris; Masud, Mehedi; Prakash, Suprabh

    2015-01-01

    With the Deep Underground Neutrino Experiment (DUNE) as an example, we show that the presence of even one sterile neutrino of mass ∼1 eV can significantly impact the measurements of CP violation in long baseline experiments. Using a probability level analysis and neutrino-antineutrino asymmetry calculations, we discuss the large magnitude of these effects, and show how they translate into significant event rate deviations at DUNE. Our results demonstrate that measurements which, when interpreted in the context of the standard three family paradigm, indicate CP conservation at long baselines, may, in fact hide large CP violation if there is a sterile state. Similarly, any data indicating the violation of CP cannot be properly interpreted within the standard paradigm unless the presence of sterile states of mass O(1 eV) can be conclusively ruled out. Our work underscores the need for a parallel and linked short baseline oscillation program and a highly capable near detector for DUNE, in order that its highly anticipated results on CP violation in the lepton sector may be correctly interpreted.

  14. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    Directory of Open Access Journals (Sweden)

    Axén Iben

    2012-07-01

    Full Text Available Abstract Background Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. Methods A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions and analytic approaches were illustrated and discussed, as well as the handling of missing data. In the applications the weekly outcome “number of days with pain” was analyzed in relation to the patients’ “previous duration of pain” (categorized as more or less than 30 days in the previous year. Research questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants “recovered” at a specific time point? This question was answered using logistic regression analysis. 3: What is the time to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor variables? This question was answered using generalized Estimating Equations, Poisson regression and Mixed linear models analyses. 5: Are there subgroups of patients with similar courses of pain

  15. Multivariate linear models and repeated measurements revisited

    DEFF Research Database (Denmark)

    Dalgaard, Peter

    2009-01-01

    Methods for generalized analysis of variance based on multivariate normal theory have been known for many years. In a repeated measurements context, it is most often of interest to consider transformed responses, typically within-subject contrasts or averages. Efficiency considerations leads...... to sphericity assumptions, use of F tests and the Greenhouse-Geisser and Huynh-Feldt adjustments to compensate for deviations from sphericity. During a recent implementation of such methods in the R language, the general structure of such transformations was reconsidered, leading to a flexible specification...

  16. Determination of the Territorial Sea Baseline - Measurement Aspect

    Science.gov (United States)

    Specht, Cezary; Weintrit, Adam; Specht, Mariusz; Dabrowski, Pawel

    2017-12-01

    Determining the course of the territorial sea baseline (TSB) of the coastal state is the basis for establishing its maritime boundaries, thus becoming indirect part of maritime policy of the state. Besides the following aspects: legal and methodological as described in the conventions, acts, standards and regulations, equally important is the issue of measurement methodology with respect to the boundaries of the territorial sea. The publication discussed accuracy requirements of the TSB measurement implementation, the relationship of sea level with a choice of the method of its determination, and discussed the implementation of such a measurement on a selected example. As the test reservoir was used the 400-meter stretch of the public beach in Gdynia. During the measurements they used the GNSS geodetic receiver operating in real time based on the geodetic network - VRSnet.pl. Additionally, a comparison was made of the applied method with analogous measurements of the TSB performed in 1999.

  17. Sport and team differences on baseline measures of sport-related concussion.

    Science.gov (United States)

    Zimmer, Adam; Piecora, Kyle; Schuster, Danielle; Webbe, Frank

    2013-01-01

    With the advent of the National Collegiate Athletic Association's (NCAA's) mandating the presence and practice of concussion-management plans in collegiate athletic programs, institutions will consider potential approaches for concussion management, including both baseline and normative comparison approaches. To examine sport and team differences in baseline performance on a computer-based neurocognitive measure and 2 standard sideline measures of cognition and balance and to determine the potential effect of premorbid factors sex and height on baseline performance. Cross-sectional study. University laboratory. A total of 437 NCAA Division II student-athletes (males = 273, females = 164; age = 19.61 ± 1.64 years, height = 69.89 ± 4.04 inches [177.52 ± 10.26 cm]) were recruited during mandatory preseason testing conducted in a concussion-management program. The computerized Concussion Resolution Index (CRI), the Standardized Assessment of Concussion (Form A; SAC), and the Balance Error Scoring System (BESS). Players on the men's basketball team tended to perform worse on the baseline measures, whereas soccer players tended to perform better. We found a difference in total BESS scores between these sports (P = .002). We saw a difference between sports on the hard-surface portion of the BESS (F6,347 = 3.33, P = .003, ηp(2) = 0.05). No sport, team, or sex differences were found with SAC scores (P > .05). We noted differences between sports and teams in the CRI indices, with basketball, particularly the men's team, performing worse than soccer (P sport differences, height was a covariate for the team (F1,385 = 5.109, P = .02, ηp(2) = 0.013) and sport (F1,326 = 11.212, P = .001, ηp(2) = 0.033) analyses, but the interaction of sex and sport on CRI indices was not significant in any test (P > .05). Given that differences in neurocognitive functioning and performance among sports and teams exist, the comparison of posttraumatic and baseline assessment may lead to more

  18. Muscle damage and repeated bout effect induced by enhanced eccentric squats.

    Science.gov (United States)

    Coratella, Giuseppe; Chemello, Alessandro; Schena, Federico

    2016-12-01

    Muscle damage and repeated bout effect have been studied after pure eccentric-only exercise. The aim of this study was to evaluate muscle damage and repeated bout effect induced by enhanced eccentric squat exercise using flywheel device. Thirteen healthy males volunteered for this study. Creatine kinase blood activity (CK), quadriceps isometric peak torque and muscle soreness were used as markers of muscle damage. The dependent parameters were measured at baseline, immediately after and each day up to 96 hours after the exercise session. The intervention consisted of 100 repetitions of enhanced eccentric squat exercise using flywheel device. The same protocol was repeated after 4 weeks. After the first bout, CK and muscle soreness were significantly greater (P0.05), while isometric peak torque and muscle soreness returned to values similar to baseline after respectively 48 and 72 hours. All muscle damage markers were significantly lower after second compared to first bout. The enhanced eccentric exercise induced symptoms of muscle damage up to 96 hours. However, it provided muscle protection after the second bout, performed four weeks later. Although it was not eccentric-only exercise, the enhancement of eccentric phase provided muscle protection.

  19. Measurement of baseline and orientation between distributed aerospace platforms.

    Science.gov (United States)

    Wang, Wen-Qin

    2013-01-01

    Distributed platforms play an important role in aerospace remote sensing, radar navigation, and wireless communication applications. However, besides the requirement of high accurate time and frequency synchronization for coherent signal processing, the baseline between the transmitting platform and receiving platform and the orientation of platform towards each other during data recording must be measured in real time. In this paper, we propose an improved pulsed duplex microwave ranging approach, which allows determining the spatial baseline and orientation between distributed aerospace platforms by the proposed high-precision time-interval estimation method. This approach is novel in the sense that it cancels the effect of oscillator frequency synchronization errors due to separate oscillators that are used in the platforms. Several performance specifications are also discussed. The effectiveness of the approach is verified by simulation results.

  20. Analysis of oligonucleotide array experiments with repeated measures using mixed models

    Directory of Open Access Journals (Sweden)

    Getchell Thomas V

    2004-12-01

    Full Text Available Abstract Background Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease or absence (Control of the disease, and brain regions including olfactory bulb (OB or cerebellum (CER. In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. Results In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH procedure of controlling false discovery rate (FDR at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the α-level (αnew = 0.0033 determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD procedure at the level of αnew to control the family-wise error rate (FWER for each gene examined. Conclusions A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  1. Joint modelling of repeated measurement and time-to-event data: an introductory tutorial.

    Science.gov (United States)

    Asar, Özgür; Ritchie, James; Kalra, Philip A; Diggle, Peter J

    2015-02-01

    The term 'joint modelling' is used in the statistical literature to refer to methods for simultaneously analysing longitudinal measurement outcomes, also called repeated measurement data, and time-to-event outcomes, also called survival data. A typical example from nephrology is a study in which the data from each participant consist of repeated estimated glomerular filtration rate (eGFR) measurements and time to initiation of renal replacement therapy (RRT). Joint models typically combine linear mixed effects models for repeated measurements and Cox models for censored survival outcomes. Our aim in this paper is to present an introductory tutorial on joint modelling methods, with a case study in nephrology. We describe the development of the joint modelling framework and compare the results with those obtained by the more widely used approaches of conducting separate analyses of the repeated measurements and survival times based on a linear mixed effects model and a Cox model, respectively. Our case study concerns a data set from the Chronic Renal Insufficiency Standards Implementation Study (CRISIS). We also provide details of our open-source software implementation to allow others to replicate and/or modify our analysis. The results for the conventional linear mixed effects model and the longitudinal component of the joint models were found to be similar. However, there were considerable differences between the results for the Cox model with time-varying covariate and the time-to-event component of the joint model. For example, the relationship between kidney function as measured by eGFR and the hazard for initiation of RRT was significantly underestimated by the Cox model that treats eGFR as a time-varying covariate, because the Cox model does not take measurement error in eGFR into account. Joint models should be preferred for simultaneous analyses of repeated measurement and survival data, especially when the former is measured with error and the association

  2. Polarized Redundant-Baseline Calibration for 21 cm Cosmology Without Adding Spectral Structure

    Science.gov (United States)

    Dillon, Joshua S.; Kohn, Saul A.; Parsons, Aaron R.; Aguirre, James E.; Ali, Zaki S.; Bernardi, Gianni; Kern, Nicholas S.; Li, Wenyang; Liu, Adrian; Nunhokee, Chuneeta D.; Pober, Jonathan C.

    2018-04-01

    21 cm cosmology is a promising new probe of the evolution of visible matter in our universe, especially during the poorly-constrained Cosmic Dawn and Epoch of Reionization. However, in order to separate the 21 cm signal from bright astrophysical foregrounds, we need an exquisite understanding of our telescopes so as to avoid adding spectral structure to spectrally-smooth foregrounds. One powerful calibration method relies on repeated simultaneous measurements of the same interferometric baseline to solve for the sky signal and for instrumental parameters simultaneously. However, certain degrees of freedom are not constrained by asserting internal consistency between redundant measurements. In this paper, we review the origin of these degeneracies of redundant-baseline calibration and demonstrate how they can source unwanted spectral structure in our measurement and show how to eliminate that additional, artificial structure. We also generalize redundant calibration to dual-polarization instruments, derive the degeneracy structure, and explore the unique challenges to calibration and preserving spectral smoothness presented by a polarized measurement.

  3. MARBLE (Multiple Antenna Radio-interferometry for Baseline Length Evaluation): Development of a Compact VLBI System for Calibrating GNSS and Electronic Distance Measurement Devices

    Science.gov (United States)

    Ichikawa, R.; Ishii, A.; Takiguchi, H.; Kimura, M.; Sekido, M.; Takefuji, K.; Ujihara, H.; Hanado, Y.; Koyama, Y.; Kondo, T.; Kurihara, S.; Kokado, K.; Kawabata, R.; Nozawa, K.; Mukai, Y.; Kuroda, J.; Ishihara, M.; Matsuzaka, S.

    2012-12-01

    We are developing a compact VLBI system with a 1.6-m diameter aperture dish in order to provide reference baseline lengths for calibration. The reference baselines are used to validate surveying instruments such as GPS and EDM and is maintained by the Geospatial Information Authority of Japan (GSI). The compact VLBI system will be installed at both ends of the reference baseline. Since the system is not sensitive enough to detect fringes between the two small dishes, we have designed a new observation concept including one large dish station. We can detect two group delays between each compact VLBI system and the large dish station based on conventional VLBI measurement. A group delay between the two compact dishes can be indirectly calculated using a simple equation. We named the idea "Multiple Antenna Radio-interferometry for Baseline Length Evaluation", or MARBLE system. The compact VLBI system is easy transportable and consists of the compact dish, a new wide-band front-end system, azimuth and elevation drive units, an IF down-converter unit, an antenna control unit (ACU), a counterweight, and a monument pillar. Each drive unit is equipped with a zero-backlash harmonic drive gearing component. A monument pillar is designed to mount typical geodetic GNSS antennas easily and an offset between the GNSS antenna reference point. The location of the azimuth-elevation crossing point of the VLBI system is precisely determined with an uncertainty of less than 0.2 mm. We have carried out seven geodetic VLBI experiments on the Kashima-Tsukuba baseline (about 54 km) using the two prototypes of the compact VLBI system between December 2009 and December 2010. The average baseline length and repeatability of the experiments is 54184874.0 ± 2.4 mm. The results are well consistent with those obtained by GPS measurements. In addition, we are now planning to use the compact VLBI system for precise time and frequency comparison between separated locations.

  4. A simple technique investigating baseline heterogeneity helped to eliminate potential bias in meta-analyses.

    Science.gov (United States)

    Hicks, Amy; Fairhurst, Caroline; Torgerson, David J

    2018-03-01

    To perform a worked example of an approach that can be used to identify and remove potentially biased trials from meta-analyses via the analysis of baseline variables. True randomisation produces treatment groups that differ only by chance; therefore, a meta-analysis of a baseline measurement should produce no overall difference and zero heterogeneity. A meta-analysis from the British Medical Journal, known to contain significant heterogeneity and imbalance in baseline age, was chosen. Meta-analyses of baseline variables were performed and trials systematically removed, starting with those with the largest t-statistic, until the I 2 measure of heterogeneity became 0%, then the outcome meta-analysis repeated with only the remaining trials as a sensitivity check. We argue that heterogeneity in a meta-analysis of baseline variables should not exist, and therefore removing trials which contribute to heterogeneity from a meta-analysis will produce a more valid result. In our example none of the overall outcomes changed when studies contributing to heterogeneity were removed. We recommend routine use of this technique, using age and a second baseline variable predictive of outcome for the particular study chosen, to help eliminate potential bias in meta-analyses. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  6. CASA Uno GPS orbit and baseline experiments

    Science.gov (United States)

    Schutz, B. E.; Ho, C. S.; Abusali, P. A. M.; Tapley, B. D.

    1990-01-01

    CASA Uno data from sites distributed in longitude from Australia to Europe have been used to determine orbits of the GPS satellites. The characteristics of the orbits determined from double difference phase have been evaluated through comparisons of two-week solutions with one-week solutions and by comparisons of predicted and estimated orbits. Evidence of unmodeled effects is demonstrated, particularly associated with the orbit planes that experience solar eclipse. The orbit accuracy has been assessed through the repeatability of unconstrained estimated baseline vectors ranging from 245 km to 5400 km. Both the baseline repeatability and the comparison with independent space geodetic methods give results at the level of 1-2 parts in 100,000,000. In addition, the Mojave/Owens Valley (245 km) and Kokee Park/Ft. Davis (5409 km) estimates agree with VLBI and SLR to better than 1 part in 100,000,000.

  7. High Baseline Postconcussion Symptom Scores and Concussion Outcomes in Athletes.

    Science.gov (United States)

    Custer, Aimee; Sufrinko, Alicia; Elbin, R J; Covassin, Tracey; Collins, Micky; Kontos, Anthony

    2016-02-01

    Some healthy athletes report high levels of baseline concussion symptoms, which may be attributable to several factors (eg, illness, personality, somaticizing). However, the role of baseline symptoms in outcomes after sport-related concussion (SRC) has not been empirically examined. To determine if athletes with high symptom scores at baseline performed worse than athletes without baseline symptoms on neurocognitive testing after SRC. Cohort study. High school and collegiate athletic programs. A total of 670 high school and collegiate athletes participated in the study. Participants were divided into groups with either no baseline symptoms (Postconcussion Symptom Scale [PCSS] score = 0, n = 247) or a high level of baseline symptoms (PCSS score > 18 [top 10% of sample], n = 68). Participants were evaluated at baseline and 2 to 7 days after SRC with the Immediate Post-concussion Assessment and Cognitive Test and PCSS. Outcome measures were Immediate Post-concussion Assessment and Cognitive Test composite scores (verbal memory, visual memory, visual motor processing speed, and reaction time) and total symptom score on the PCSS. The groups were compared using repeated-measures analyses of variance with Bonferroni correction to assess interactions between group and time for symptoms and neurocognitive impairment. The no-symptoms group represented 38% of the original sample, whereas the high-symptoms group represented 11% of the sample. The high-symptoms group experienced a larger decline from preinjury to postinjury than the no-symptoms group in verbal (P = .03) and visual memory (P = .05). However, total concussion-symptom scores increased from preinjury to postinjury for the no-symptoms group (P = .001) but remained stable for the high-symptoms group. Reported baseline symptoms may help identify athletes at risk for worse outcomes after SRC. Clinicians should examine baseline symptom levels to better identify patients for earlier referral and treatment for their

  8. Analysis of repeated measurement data in the clinical trials

    Science.gov (United States)

    Singh, Vineeta; Rana, Rakesh Kumar; Singhal, Richa

    2013-01-01

    Statistics is an integral part of Clinical Trials. Elements of statistics span Clinical Trial design, data monitoring, analyses and reporting. A solid understanding of statistical concepts by clinicians improves the comprehension and the resulting quality of Clinical Trials. In biomedical research it has been seen that researcher frequently use t-test and ANOVA to compare means between the groups of interest irrespective of the nature of the data. In Clinical Trials we record the data on the patients more than two times. In such a situation using the standard ANOVA procedures is not appropriate as it does not consider dependencies between observations within subjects in the analysis. To deal with such types of study data Repeated Measure ANOVA should be used. In this article the application of One-way Repeated Measure ANOVA has been demonstrated by using the software SPSS (Statistical Package for Social Sciences) Version 15.0 on the data collected at four time points 0 day, 15th day, 30th day, and 45th day of multicentre clinical trial conducted on Pandu Roga (~Iron Deficiency Anemia) with an Ayurvedic formulation Dhatrilauha. PMID:23930038

  9. Analysis of baseline, average, and longitudinally measured blood pressure data using linear mixed models.

    Science.gov (United States)

    Hossain, Ahmed; Beyene, Joseph

    2014-01-01

    This article compares baseline, average, and longitudinal data analysis methods for identifying genetic variants in genome-wide association study using the Genetic Analysis Workshop 18 data. We apply methods that include (a) linear mixed models with baseline measures, (b) random intercept linear mixed models with mean measures outcome, and (c) random intercept linear mixed models with longitudinal measurements. In the linear mixed models, covariates are included as fixed effects, whereas relatedness among individuals is incorporated as the variance-covariance structure of the random effect for the individuals. The overall strategy of applying linear mixed models decorrelate the data is based on Aulchenko et al.'s GRAMMAR. By analyzing systolic and diastolic blood pressure, which are used separately as outcomes, we compare the 3 methods in identifying a known genetic variant that is associated with blood pressure from chromosome 3 and simulated phenotype data. We also analyze the real phenotype data to illustrate the methods. We conclude that the linear mixed model with longitudinal measurements of diastolic blood pressure is the most accurate at identifying the known single-nucleotide polymorphism among the methods, but linear mixed models with baseline measures perform best with systolic blood pressure as the outcome.

  10. An Approach for Measuring Reductions in Operations, Maintenance, and Energy Costs: Baseline Measures of Construction Industry Practices for the National Construction Goals.

    Science.gov (United States)

    Chapman, Robert E.; Rennison, Roderick

    The Construction and Building Subcommittee of the National Science and Technology Council (NSTC) has established seven National Construction Goals for the construction industry and is developing baseline measures for current practices and progress with respect to each goal. This document provides a detailed set of baseline measures for the NSTC…

  11. Near-Peer Teaching in Paramedic Education: A Repeated Measures Design

    Science.gov (United States)

    Williams, Brett; Nguyen, David

    2017-01-01

    The transition of the Australian paramedic discipline from vocation education and training to the higher education sector has seen a sharp rise in interest in near-peer teaching (NPT). The objective of this study was to examine satisfaction levels of NPT over one academic semester among undergraduate paramedic students. A repeated measured design…

  12. Cross-trimester repeated measures testing for Down's syndrome screening: an assessment.

    LENUS (Irish Health Repository)

    Wright, D

    2010-07-01

    To provide estimates and confidence intervals for the performance (detection and false-positive rates) of screening for Down\\'s syndrome using repeated measures of biochemical markers from first and second trimester maternal serum samples taken from the same woman.

  13. Repeated touch and needle-prick stimulation in the neonatal period increases the baseline mechanical sensitivity and postinjury hypersensitivity of adult spinal sensory neurons.

    Science.gov (United States)

    van den Hoogen, Nynke J; Patijn, Jacob; Tibboel, Dick; Joosten, Bert A; Fitzgerald, Maria; Kwok, Charlie H T

    2018-03-08

    Noxious stimulation at critical stages of development has long-term consequences on somatosensory processing in later life, but it is not known whether this developmental plasticity is restricted to nociceptive pathways. Here, we investigate the effect of repeated neonatal noxious or innocuous hind paw stimulation on adult spinal dorsal horn cutaneous mechanical sensitivity. Neonatal Sprague-Dawley rats of both sexes received 4 unilateral left hind paw needle pricks (NPs, n = 13) or 4 tactile (cotton swab touch) stimuli, per day (TC, n = 11) for the first 7 days of life. Control pups were left undisturbed (n = 17). When adult (6-8 weeks), lumbar wide-dynamic-range neuron activity in laminae III-V was recorded using in vivo extracellular single-unit electrophysiology. Spike activity evoked by cutaneous dynamic tactile (brush), pinch and punctate (von Frey hair) stimulation, and plantar receptive field areas were recorded, at baseline and 2 and 5 days after left plantar hind paw incision. Baseline brush receptive fields, von Frey hair, and pinch sensitivity were significantly enhanced in adult NP and TC animals compared with undisturbed controls, although effects were greatest in NP rats. After incision, injury sensitivity of adult wide-dynamic-range neurons to both noxious and dynamic tactile hypersensitivity was significantly greater in NP animals compared with TC and undisturbed controls. We conclude that both repeated touch and needle-prick stimulation in the neonatal period can alter adult spinal sensory neuron sensitivity to both innocuous and noxious mechanical stimulation. Thus, spinal sensory circuits underlying touch and pain processing are shaped by a range of early-life somatosensory experiences.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  14. Measuring environmental change in forest ecosystems by repeated soil sampling: A North American perspective

    Science.gov (United States)

    Gregory B. Lawrence; Ivan J. Fernandez; Daniel D. Richter; Donald S. Ross; Paul W. Hazlett; Scott W. Bailey; Rock Ouimet; Richard A. F. Warby; Arthur H. Johnson; Henry Lin; James M. Kaste; Andrew G. Lapenis; Timothy J. Sullivan

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest...

  15. Antarctic Ice Sheet Slope and Aspect Based on Icesat's Repeat Orbit Measurement

    Science.gov (United States)

    Yuan, L.; Li, F.; Zhang, S.; Xie, S.; Xiao, F.; Zhu, T.; Zhang, Y.

    2017-09-01

    Accurate information of ice sheet surface slope is essential for estimating elevation change by satellite altimetry measurement. A study is carried out to recover surface slope of Antarctic ice sheet from Ice, Cloud and land Elevation Satellite (ICESat) elevation measurements based on repeat orbits. ICESat provides repeat ground tracks within 200 meters in cross-track direction and 170 meters in along-track direction for most areas of Antarctic ice sheet. Both cross-track and along-track surface slopes could be obtained by adjacent repeat ground tracks. Combining those measurements yields a surface slope model with resolution of approximately 200 meters. An algorithm considering elevation change is developed to estimate the surface slope of Antarctic ice sheet. Three Antarctic Digital Elevation Models (DEMs) were used to calculate surface slopes. The surface slopes from DEMs are compared with estimates by using in situ GPS data in Dome A, the summit of Antarctic ice sheet. Our results reveal an average surface slope difference of 0.02 degree in Dome A. High resolution remote sensing images are also used in comparing the results derived from other DEMs and this paper. The comparison implies that our results have a slightly better coherence with GPS observation than results from DEMs, but our results provide more details and perform higher accuracy in coastal areas because of the higher resolution for ICESat measurements. Ice divides are estimated based on the aspect, and are weakly consistent with ice divides from other method in coastal regions.

  16. Acute effects of repeated bouts of aerobic exercise on arterial stiffness after glucose ingestion.

    Science.gov (United States)

    Kobayashi, Ryota; Hashimoto, Yuto; Hatakeyama, Hiroyuki; Okamoto, Takanobu

    2018-03-22

    The aim of this study was to investigate the acute repeated bouts of aerobic exercise decrease leg arterial stiffness. However, the influence of repeated bouts of aerobic exercise on arterial stiffness after glucose ingestion is unknown. The present study investigates the acute effects of repeated bouts of aerobic exercise on arterial stiffness after the 75-g oral glucose tolerance test (OGTT). Ten healthy young men (age, 23.2 ± 0.9 years) performed repeated bouts of aerobic exercise trial (RE, 65% peak oxygen uptake; two 15 min bouts of cycling performed 20 min apart) and control trial (CON, seated and resting in a quiet room) at 80 min before the 75-g OGTT on separate days in a randomized, controlled crossover fashion. Carotid-femoral (aortic) and femoral-ankle (leg) pulse wave velocity, carotid augmentation index, brachial and ankle blood pressure, heart rate and blood glucose and insulin levels were measured before (baseline) and 30, 60 and 120 min after the 75-g OGTT. Leg pulse wave velocity, ankle systolic blood pressure and blood glucose levels increased from baseline after the 75-g OGTT in the CON trial, but not in the RE trial. The present findings indicate that acute repeated bouts of aerobic exercise before glucose ingestion suppress increases in leg arterial stiffness following glucose ingestion. RE trial repeated bouts of aerobic exercise trial; CON trial control trial; BG blood glucose; VO 2peak peak oxygen uptake; PWV Pulse wave velocity; AIx carotid augmentation index; BP blood pressure; HR heart rate; CVs coefficients of variation; RPE Ratings of perceived exertion; SE standard error.

  17. Repeatability of Retinal Sensitivity Measurements Using a Medmont Dark-Adapted Chromatic Perimeter in Healthy and Age-Related Macular Degeneration Cases.

    Science.gov (United States)

    Tan, Rose S; Guymer, Robyn H; Luu, Chi D

    2018-05-01

    To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.

  18. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  19. Measurement System Analyses - Gauge Repeatability and Reproducibility Methods

    Science.gov (United States)

    Cepova, Lenka; Kovacikova, Andrea; Cep, Robert; Klaput, Pavel; Mizera, Ondrej

    2018-02-01

    The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.

  20. Unitarity, Feedback, Interactions - Dynamics Emergent from Repeated Measurements

    Science.gov (United States)

    Corona Ugalde, Paulina; Altamirano, Natacha; Mann, Robert; Zych, Magdalena

    Modern measurement theory dispenses with the description of a measurement as a projection. Rather, the measurement is understood as an operation, whereby the system's final state is determined by an action of a completely positive trace non-increasing map and the outcomes are described by linear operators on the system, distributed according to a positive-operator valued measure (POVM). The POVM approach unifies the theory of measurements with a general description of dynamics, the theory of open quantum systems. Engineering a particular measurement and engineering a particular dynamics for the system are thus two complementary aspects of the same conceptual framework. This correspondence is directly applied in quantum simulations and quantum control theory . With this motivation, we study what types of dynamics can emerge from a model of repeated short interactions of a system with a set of ancillae. We show that contingent on the model parameters the resulting dynamics ranges from exact unitarity to arbitrary fast decoherence. For a series of measurements the effective dynamics includes feedback-control, which for a composite system yields effective interactions between the subsystems. We quantify the amount of decoherence accompanying such induced interactions. The simple framework used in the present study can find applications in devising novel quantum control protocols, or quantum simulations.

  1. Classifying vulnerability to sleep deprivation using baseline measures of psychomotor vigilance.

    Science.gov (United States)

    Patanaik, Amiya; Kwoh, Chee Keong; Chua, Eric C P; Gooley, Joshua J; Chee, Michael W L

    2015-05-01

    To identify measures derived from baseline psychomotor vigilance task (PVT) performance that can reliably predict vulnerability to sleep deprivation. Subjects underwent total sleep deprivation and completed a 10-min PVT every 1-2 h in a controlled laboratory setting. Participants were categorized as vulnerable or resistant to sleep deprivation, based on a median split of lapses that occurred following sleep deprivation. Standard reaction time, drift diffusion model (DDM), and wavelet metrics were derived from PVT response times collected at baseline. A support vector machine model that incorporated maximum relevance and minimum redundancy feature selection and wrapper-based heuristics was used to classify subjects as vulnerable or resistant using rested data. Two academic sleep laboratories. Independent samples of 135 (69 women, age 18 to 25 y), and 45 (3 women, age 22 to 32 y) healthy adults. In both datasets, DDM measures, number of consecutive reaction times that differ by more than 250 ms, and two wavelet features were selected by the model as features predictive of vulnerability to sleep deprivation. Using the best set of features selected in each dataset, classification accuracy was 77% and 82% using fivefold stratified cross-validation, respectively. In both datasets, DDM measures, number of consecutive reaction times that differ by more than 250 ms, and two wavelet features were selected by the model as features predictive of vulnerability to sleep deprivation. Using the best set of features selected in each dataset, classification accuracy was 77% and 82% using fivefold stratified cross-validation, respectively. Despite differences in experimental conditions across studies, drift diffusion model parameters associated reliably with individual differences in performance during total sleep deprivation. These results demonstrate the utility of drift diffusion modeling of baseline performance in estimating vulnerability to psychomotor vigilance decline

  2. Comparability and repeatability of three commonly used methods for measuring endurance capacity.

    Science.gov (United States)

    Baxter-Gilbert, James; Mühlenhaupt, Max; Whiting, Martin J

    2017-12-01

    Measures of endurance (time to exhaustion) have been used to address a wide range of questions in ecomorphological and physiological research, as well as being used as a proxy for survival and fitness. Swimming, stationary (circular) track running, and treadmill running are all commonly used methods for measuring endurance. Despite the use of these methods across a broad range of taxa, how comparable these methods are to one another, and whether they are biologically relevant, is rarely examined. We used Australian water dragons (Intellagama lesueurii), a species that is morphologically adept at climbing, swimming, and running, to compare these three methods of endurance and examined if there is repeatability within and between trial methods. We found that time to exhaustion was not highly repeatable within a method, suggesting that single measures or a mean time to exhaustion across trials are not appropriate. Furthermore, we compared mean maximal endurance times among the three methods, and found that the two running methods (i.e., stationary track and treadmill) were similar, but swimming was distinctly different, resulting in lower mean maximal endurance times. Finally, an individual's endurance rank was not repeatable across methods, suggesting that the three endurance trial methods are not providing similar information about an individual's performance capacity. Overall, these results highlight the need to carefully match a measure of performance capacity with the study species and the research questions being asked so that the methods being used are behaviorally, ecologically, and physiologically relevant. © 2018 Wiley Periodicals, Inc.

  3. Forest Structure Characterization Using Jpl's UAVSAR Multi-Baseline Polarimetric SAR Interferometry and Tomography

    Science.gov (United States)

    Neumann, Maxim; Hensley, Scott; Lavalle, Marco; Ahmed, Razi

    2013-01-01

    This paper concerns forest remote sensing using JPL's multi-baseline polarimetric interferometric UAVSAR data. It presents exemplary results and analyzes the possibilities and limitations of using SAR Tomography and Polarimetric SAR Interferometry (PolInSAR) techniques for the estimation of forest structure. Performance and error indicators for the applicability and reliability of the used multi-baseline (MB) multi-temporal (MT) PolInSAR random volume over ground (RVoG) model are discussed. Experimental results are presented based on JPL's L-band repeat-pass polarimetric interferometric UAVSAR data over temperate and tropical forest biomes in the Harvard Forest, Massachusetts, and in the La Amistad Park, Panama and Costa Rica. The results are partially compared with ground field measurements and with air-borne LVIS lidar data.

  4. Repeatability of junctional zone measurements using three-dimensional transvaginal ultrasound in healthy, fertile women

    DEFF Research Database (Denmark)

    Rasmussen, Christina Kjærgaard; Glavind, Julie; Madsen, Lene Duch

    2016-01-01

    -observer repeatability was evaluated according to the Bland-Altman method and expressed as coefficient of repeatability (CoR). Results: Using 3D-TVS we visualised a thin and regular JZ in most women. The posterior uterine wall had the largest median (interquartile range; iqr) value of JZmax (5.2 (iqr 3.8-6.5)mm. Ten out....... Correlations between measurements were poor in the narrow range of JZ thickness. Conclusions: The JZ has an indistinct outline by 3D-TVS resulting in an error of JZ measurement within a broad range of ±2-4 mm, but reduced by average measurements. The thickness of JZ varied within a narrow range of this healthy......, fertile population and reliability measurements of JZ thickness has to be evaluated in women with a wider range of JZ thickness....

  5. REPEATABILITY AND ACCURACY OF EXOPLANET ECLIPSE DEPTHS MEASURED WITH POST-CRYOGENIC SPITZER

    Energy Technology Data Exchange (ETDEWEB)

    Ingalls, James G.; Krick, J. E.; Carey, S. J.; Stauffer, John R.; Lowrance, Patrick J.; Grillmair, Carl J.; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa [Spitzer Science Center, California Institute of Technology, 1200 E California Boulevard, Mail Code 314-6, Pasadena, CA 91125 (United States); Buzasi, Derek [Department of Chemistry and Physics, Florida Gulf Coast University, Fort Myers, FL 33965 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Diamond-Lowe, Hannah; Stevenson, Kevin B. [Department of Astronomy and Astrophysics, University of Chicago, 5640 S Ellis Avenue, Chicago, IL 60637 (United States); Evans, Thomas M. [School of Physics, University of Exeter, EX4 4QL Exeter (United Kingdom); Morello, G. [Department of Physics and Astronomy, University College London, Gower Street, WC1 E6BT (United Kingdom); Wong, Ian, E-mail: ingalls@ipac.caltech.edu [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States)

    2016-08-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5 μ m data set, consisting of 10 observations of the XO-3b system during secondary eclipse, using seven different techniques for removing correlated noise. We find that, on average, for a given technique, the eclipse depth estimate is repeatable from epoch to epoch to within 156 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 3 of the photon noise limit. All methods but one accurately assess their own errors: for these methods, the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10 epoch sample. To assess the accuracy of the techniques as well as to clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated data set of 10 visits to XO-3b, for which the eclipse depth is known. We find that three of the methods (BLISS mapping, Pixel Level Decorrelation, and Independent Component Analysis) obtain results that are within three times the photon limit of the true eclipse depth. When averaged over the 10 epoch ensemble,  5 out of 7 techniques come within 60 ppm of the true value. Spitzer exoplanet data, if obtained following current best practices and reduced using methods such as those described here, can measure repeatable and accurate single eclipse depths, with close to photon-limited results.

  6. Repeatability of Computerized Tomography-Based Anthropomorphic Measurements of Frailty in Patients With Pulmonary Fibrosis Undergoing Lung Transplantation.

    Science.gov (United States)

    McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R

    To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations

  7. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    International Nuclear Information System (INIS)

    Kroner, E; Arzt, E; Maboudian, R

    2009-01-01

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  8. Baseline factors that influence ASAS 20 response in patients with ankylosing spondylitis treated with etanercept.

    Science.gov (United States)

    Davis, John C; Van der Heijde, Désirée M F M; Dougados, Maxime; Braun, Jurgen; Cush, John J; Clegg, Daniel O; Inman, Robert D; de Vries, Todd; Tsuji, Wayne H

    2005-09-01

    To examine the baseline demographic and disease characteristics that might influence improvement as measured by the Assessment in Ankylosing Spondylitis Response Criteria (ASAS 20) in patients with ankylosing spondylitis (AS). A multicenter Phase 3 study was performed to compare the safety and efficacy of 24 weeks of etanercept 25 mg subcutaneous injection twice weekly (n = 138) and placebo (n = 139) in patients with AS. The ASAS 20 was measured at multiple time points. Using a significance level of 0.05, a repeated measures logistic regression model was used to determine which baseline factors influenced response in the etanercept-treated patients during the 24-week double blind portion of the trial. The following baseline factors were used in the model: demographic and disease severity variables, concomitant medications, extra-articular manifestations, and HLA-B27 status. The predictive capability of the model was then tested on the patients receiving placebo after they had received open-label etanercept treatment. Baseline factors that were significant predictors of an ASAS 20 response in etanercept-treated patients were C-reactive protein (CRP), back pain score, and Bath Ankylosing Spondylitis Functional Index (BASFI) score. Although clinical response to etanercept was seen at all levels of baseline disease activity, responses were consistently more likely with higher CRP levels or back pain scores and less likely with increased BASFI scores at baseline. Higher CRP values and back pain scores and lower BASFI scores at baseline were significant predictors of a higher ASAS 20 response in patients with AS receiving etanercept but predictive value was of insufficient magnitude to determine treatment in individual patients.

  9. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuan-Pei; Zhang, Bing, E-mail: yypspore@gmail.com, E-mail: zhang@physics.unlv.edu [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2017-09-20

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  10. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    International Nuclear Information System (INIS)

    Yang, Yuan-Pei; Zhang, Bing

    2017-01-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  11. On summary measure analysis of linear trend repeated measures data: performance comparison with two competing methods.

    Science.gov (United States)

    Vossoughi, Mehrdad; Ayatollahi, S M T; Towhidi, Mina; Ketabchi, Farzaneh

    2012-03-22

    The summary measure approach (SMA) is sometimes the only applicable tool for the analysis of repeated measurements in medical research, especially when the number of measurements is relatively large. This study aimed to describe techniques based on summary measures for the analysis of linear trend repeated measures data and then to compare performances of SMA, linear mixed model (LMM), and unstructured multivariate approach (UMA). Practical guidelines based on the least squares regression slope and mean of response over time for each subject were provided to test time, group, and interaction effects. Through Monte Carlo simulation studies, the efficacy of SMA vs. LMM and traditional UMA, under different types of covariance structures, was illustrated. All the methods were also employed to analyze two real data examples. Based on the simulation and example results, it was found that the SMA completely dominated the traditional UMA and performed convincingly close to the best-fitting LMM in testing all the effects. However, the LMM was not often robust and led to non-sensible results when the covariance structure for errors was misspecified. The results emphasized discarding the UMA which often yielded extremely conservative inferences as to such data. It was shown that summary measure is a simple, safe and powerful approach in which the loss of efficiency compared to the best-fitting LMM was generally negligible. The SMA is recommended as the first choice to reliably analyze the linear trend data with a moderate to large number of measurements and/or small to moderate sample sizes.

  12. Measurement of repeat effects in Chicago’s criminal social network

    Directory of Open Access Journals (Sweden)

    Paul Kump

    2016-07-01

    Full Text Available The “near-repeat” effect is a well-known criminological phenomenon in which the occurrence of a crime incident gives rise to a temporary elevation of crime risk within close physical proximity to an initial incident. Adopting a social network perspective, we instead define a near repeat in terms of geodesic distance within a criminal social network, rather than spatial distance. Specifically, we report a statistical analysis of repeat effects in arrest data for Chicago during the years 2003–2012. We divide the arrest data into two sets (violent crimes and other crimes and, for each set, we compare the distributions of time intervals between repeat incidents to theoretical distributions in which repeat incidents occur only by chance. We first consider the case of the same arrestee participating in repeat incidents (“exact repeats” and then extend the analysis to evaluate repeat risks of those arrestees near one another in the social network. We observe repeat effects that diminish as a function of geodesic distance and time interval, and we estimate typical time scales for repeat crimes in Chicago.

  13. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and

  14. Formatting data files for repeated-measures analyses in SPSS: Using the Aggregate and Restructure procedures

    Directory of Open Access Journals (Sweden)

    Gyslain Giguère

    2006-03-01

    Full Text Available In this tutorial, we demonstrate how to use the Aggregate and Restructure procedures available in SPSS (versions 11 and up to prepare data files for repeated-measures analyses. In the first two sections of the tutorial, we briefly describe the Aggregate and Restructure procedures. In the final section, we present an example in which the data from a fictional lexical decision task are prepared for analysis using a mixed-design ANOVA. The tutorial demonstrates that the presented method is the most efficient way to prepare data for repeated-measures analyses in SPSS.

  15. Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software.

    Science.gov (United States)

    Lopez, Natalia; Perez, Elisa; Tello, Emanuel; Rodrigo, Alejandro; Valentinuzzi, Max E

    2018-01-01

    The rehabilitation process is a fundamental stage for recovery of people's capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient's evolution. This paper proposes a tracking platform of the movement made by an individual's upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient's data. For clinical purposes, the software information is statistically validated with three different methodologies, comparing the measures with a goniometer in terms of agreement and repeatability. The agreement of joint angles measured with the proposed software and goniometer is evaluated with Bland-Altman plots; all measurements fell well within the limits of agreement, meaning interchangeability of both techniques. Additionally, the results of Bland-Altman analysis of repeatability show 95% confidence. Finally, the physiotherapists' qualitative assessment shows encouraging results for the clinical use. The main conclusion is that the software is capable of offering a clinical history of the patient and is useful for quantification of the rehabilitation success. The simplicity, low cost, and visualization possibilities enhance the use of the software Kinect for rehabilitation and other applications, and the expert's opinion endorses the choice of our approach for clinical practice. Comparison of the new measurement technique with established

  16. Repeated measurements of cerebral blood flow in the left superior temporal gyrus reveal tonic hyperactivity in patients with auditory verbal hallucinations: A possible trait marker

    Directory of Open Access Journals (Sweden)

    Philipp eHoman

    2013-06-01

    Full Text Available Background: The left superior temporal gyrus (STG has been suggested to play a key role in auditory verbal hallucinations in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant auditory verbal hallucinations and 19 healthy controls underwent perfusion magnetic resonance imaging with arterial spin labeling. Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF, which consisted of the regional CBF measurement in the left superior temporal gyrus (STG and the global CBF measurement in the whole brain.Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001 and to the global CBF in patients (p < 0.004 at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007, and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001. After TMS, PANSS (p = 0.003 and PSYRATS (p = 0.01 scores decreased significantly in patients.Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of auditory verbal hallucinations in schizophrenia.

  17. Power analysis for multivariate and repeated measurements designs via SPSS: correction and extension of D'Amico, Neilands, and Zambarano (2001).

    Science.gov (United States)

    Osborne, Jason W

    2006-05-01

    D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.

  18. Validation of Repeated Endothelial Function Measurements Using EndoPAT in Stroke

    DEFF Research Database (Denmark)

    Hansen, Aina S; Butt, Jawad H; Holm-Yildiz, Sonja

    2017-01-01

    BACKGROUND: Decreased endothelial function (EF) may be a prognostic marker for stroke. Measuring pharmacological effects on EF may be of interest in the development of personalized medicine for stroke prevention. In this study, we assessed the reliability of repeated EF measurements using a pulse......%, mean age 35.85 ± 3.47 years) and 21 stroke patients (men 52%, mean age 66.38 ± 2.85 years, and mean NIHSS 4.09 ± 0.53) under standardized conditions. EF was measured as the reactive hyperemia index (RHI), logarithm of RHI (lnRHI), and Framingham RHI (fRHI). Measurements were separated by 1.5 and 24 h...

  19. The effect of repeated measurements and working memory on the most comfortable level in the ANL test.

    Science.gov (United States)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas; Kastberg, Tobias; Ibertsson, Tina

    2014-11-01

    To study the effect of a large number of repetitions on the most comfortable level (MCL) when doing the acceptable noise level (ANL) test, and explore if MCL variability is related to central cognitive processes. Twelve MCL repetitions were measured within the ANL test using interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. Thirty-two normal-hearing adults. Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used to assess the repeatability. Repeated measures ANOVA and CR indicated poor agreement between the two first repetitions. After excluding the first repetition, analyses showed that the MCL in the ANL test is reliable. A negative association was found between PWM and MCL variability indicating that subjects with higher PWM show less variability. The findings suggest that, after excluding the first repetition, the MCL in the ANL test is reliable. A single repetition of the MCL in the ANL test should be avoided. If an interleaved methodology is used, a single ANL repetition should be added prior to the actual testing. The findings also suggest that MCL variability is associated to PWM but not VSWM.

  20. Spatial cluster detection for repeatedly measured outcomes while accounting for residential history.

    Science.gov (United States)

    Cook, Andrea J; Gold, Diane R; Li, Yi

    2009-10-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information on study participants relocation, which most cluster detection statistics cannot. Application of these methods will be illustrated by the Home Allergens and Asthma prospective cohort study analyzing the relationship between environmental exposures and repeated measured outcome, occurrence of wheeze in the last 6 months, while taking into account mobile locations.

  1. Beyond total treatment effects in randomised controlled trials: Baseline measurement of intermediate outcomes needed to reduce confounding in mediation investigations.

    Science.gov (United States)

    Landau, Sabine; Emsley, Richard; Dunn, Graham

    2018-06-01

    Random allocation avoids confounding bias when estimating the average treatment effect. For continuous outcomes measured at post-treatment as well as prior to randomisation (baseline), analyses based on (A) post-treatment outcome alone, (B) change scores over the treatment phase or (C) conditioning on baseline values (analysis of covariance) provide unbiased estimators of the average treatment effect. The decision to include baseline values of the clinical outcome in the analysis is based on precision arguments, with analysis of covariance known to be most precise. Investigators increasingly carry out explanatory analyses to decompose total treatment effects into components that are mediated by an intermediate continuous outcome and a non-mediated part. Traditional mediation analysis might be performed based on (A) post-treatment values of the intermediate and clinical outcomes alone, (B) respective change scores or (C) conditioning on baseline measures of both intermediate and clinical outcomes. Using causal diagrams and Monte Carlo simulation, we investigated the performance of the three competing mediation approaches. We considered a data generating model that included three possible confounding processes involving baseline variables: The first two processes modelled baseline measures of the clinical variable or the intermediate variable as common causes of post-treatment measures of these two variables. The third process allowed the two baseline variables themselves to be correlated due to past common causes. We compared the analysis models implied by the competing mediation approaches with this data generating model to hypothesise likely biases in estimators, and tested these in a simulation study. We applied the methods to a randomised trial of pragmatic rehabilitation in patients with chronic fatigue syndrome, which examined the role of limiting activities as a mediator. Estimates of causal mediation effects derived by approach (A) will be biased if one of

  2. Baseline restoration using current conveyors

    International Nuclear Information System (INIS)

    Morgado, A.M.L.S.; Simoes, J.B.; Correia, C.M.

    1996-01-01

    A good performance of high resolution nuclear spectrometry systems, at high pulse rates, demands restoration of baseline between pulses, in order to remove rate dependent baseline shifts. This restoration is performed by circuits named baseline restorers (BLRs) which also remove low frequency noise, such as power supply hum and detector microphonics. This paper presents simple circuits for baseline restoration based on a commercial current conveyor (CCII01). Tests were performed, on two circuits, with periodic trapezoidal shaped pulses in order to measure the baseline restoration for several pulse rates and restorer duty cycles. For the current conveyor based Robinson restorer, the peak shift was less than 10 mV, for duty cycles up to 60%, at high pulse rates. Duty cycles up to 80% were also tested, being the maximum peak shift 21 mV. The peak shift for the current conveyor based Grubic restorer was also measured. The maximum value found was 30 mV at 82% duty cycle. Keeping the duty cycle below 60% improves greatly the restorer performance. The ability of both baseline restorer architectures to reject low frequency modulation is also measured, with good results on both circuits

  3. Developing RESRAD-BASELINE for environmental baseline risk assessment

    International Nuclear Information System (INIS)

    Cheng, Jing-Jy.

    1995-01-01

    RESRAD-BASELINE is a computer code developed at Argonne developed at Argonne National Laboratory for the US Department of Energy (DOE) to perform both radiological and chemical risk assessments. The code implements the baseline risk assessment guidance of the US Environmental Protection Agency (EPA 1989). The computer code calculates (1) radiation doses and cancer risks from exposure to radioactive materials, and (2) hazard indexes and cancer risks from exposure to noncarcinogenic and carcinogenic chemicals, respectively. The user can enter measured or predicted environmental media concentrations from the graphic interface and can simulate different exposure scenarios by selecting the appropriate pathways and modifying the exposure parameters. The database used by PESRAD-BASELINE includes dose conversion factors and slope factors for radionuclides and toxicity information and properties for chemicals. The user can modify the database for use in the calculation. Sensitivity analysis can be performed while running the computer code to examine the influence of the input parameters. Use of RESRAD-BASELINE for risk analysis is easy, fast, and cost-saving. Furthermore, it ensures in consistency in methodology for both radiological and chemical risk analyses

  4. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    NARCIS (Netherlands)

    Miles, J.E.; Jensen, B.R.; Kirpensteijn, J.; Svalastoga, E.L.; Eriksen, T.

    2013-01-01

    Abstract OBJECTIVE: To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind

  5. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  6. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate b...

  7. Analyzing Repeated Measures Marginal Models on Sample Surveys with Resampling Methods

    Directory of Open Access Journals (Sweden)

    James D. Knoke

    2005-12-01

    Full Text Available Packaged statistical software for analyzing categorical, repeated measures marginal models on sample survey data with binary covariates does not appear to be available. Consequently, this report describes a customized SAS program which accomplishes such an analysis on survey data with jackknifed replicate weights for which the primary sampling unit information has been suppressed for respondent confidentiality. First, the program employs the Macro Language and the Output Delivery System (ODS to estimate the means and covariances of indicator variables for the response variables, taking the design into account. Then, it uses PROC CATMOD and ODS, ignoring the survey design, to obtain the design matrix and hypothesis test specifications. Finally, it enters these results into another run of CATMOD, which performs automated direct input of the survey design specifications and accomplishes the appropriate analysis. This customized SAS program can be employed, with minor editing, to analyze general categorical, repeated measures marginal models on sample surveys with replicate weights. Finally, the results of our analysis accounting for the survey design are compared to the results of two alternate analyses of the same data. This comparison confirms that such alternate analyses, which do not properly account for the design, do not produce useful results.

  8. Modeling intraindividual variability with repeated measures data methods and applications

    CERN Document Server

    Hershberger, Scott L

    2013-01-01

    This book examines how individuals behave across time and to what degree that behavior changes, fluctuates, or remains stable.It features the most current methods on modeling repeated measures data as reported by a distinguished group of experts in the field. The goal is to make the latest techniques used to assess intraindividual variability accessible to a wide range of researchers. Each chapter is written in a ""user-friendly"" style such that even the ""novice"" data analyst can easily apply the techniques.Each chapter features:a minimum discussion of mathematical detail;an empirical examp

  9. Impact of a person-centred dementia care training programme on hospital staff attitudes, role efficacy and perceptions of caring for people with dementia: A repeated measures study.

    Science.gov (United States)

    Surr, C A; Smith, S J; Crossland, J; Robins, J

    2016-01-01

    People with dementia occupy up to one quarter of acute hospital beds. However, the quality of care delivered to this patient group is of national concern. Staff working in acute hospitals report lack of knowledge, skills and confidence in caring for people with dementia. There is limited evidence about the most effective approaches to supporting acute hospital staff to deliver more person-centred care. This study aimed to evaluate the efficacy of a specialist training programme for acute hospital staff regarding improving attitudes, satisfaction and feelings of caring efficacy, in provision of care to people with dementia. A repeated measures design, with measures completed immediately prior to commencing training (T1), after completion of Foundation level training (T2: 4-6 weeks post-baseline), and following Intermediate level training (T3: 3-4 months post-baseline). One NHS Trust in the North of England, UK. 40 acute hospital staff working in clinical roles, the majority of whom (90%) were nurses. All participants received the 3.5 day Person-centred Care Training for Acute Hospitals (PCTAH) programme, comprised of two levels, Foundation (0.5 day) and Intermediate (3 days), delivered over a 3-4 months period. Staff demographics and previous exposure to dementia training were collected via a questionnaire. Staff attitudes were measured using the Approaches to Dementia Questionnaire (ADQ), satisfaction in caring for people with dementia was captured using the Staff Experiences of Working with Demented Residents questionnaire (SEWDR) and perceived caring efficacy was measured using the Caring Efficacy Scale (CES). The training programme was effective in producing a significant positive change on all three outcome measures following intermediate training compared to baseline. A significant positive effect was found on the ADQ between baseline and after completion of Foundation level training, but not for either of the other measures. Training acute hospital staff in

  10. Beverage Intake Assessment Questionnaire: Relative Validity and Repeatability in a Spanish Population with Metabolic Syndrome from the PREDIMED-PLUS Study

    Science.gov (United States)

    Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A.; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi

    2016-01-01

    We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55–75) with a BMI ≥27 and <40 kg/m2, and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student’s t-test comparisons. A total of 160 participants were included in the analysis. The Bland–Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of −0.65 and 0.22, respectively (R2 = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability. PMID:27483318

  11. Telomere shortening unrelated to smoking, body weight, physical activity, and alcohol intake: 4,576 general population individuals with repeat measurements 10 years apart.

    Directory of Open Access Journals (Sweden)

    Maren Weischer

    2014-03-01

    Full Text Available Cross-sectional studies have associated short telomere length with smoking, body weight, physical activity, and possibly alcohol intake; however, whether these associations are due to confounding is unknown. We tested these hypotheses in 4,576 individuals from the general population cross-sectionally, and with repeat measurement of relative telomere length 10 years apart. We also tested whether change in telomere length is associated with mortality and morbidity in the general population. Relative telomere length was measured with quantitative polymerase chain reaction. Cross-sectionally at the first examination, short telomere length was associated with increased age (P for trend across quartiles = 3 × 10(-77, current smoking (P = 8 × 10(-3, increased body mass index (P = 7 × 10(-14, physical inactivity (P = 4 × 10(-17, but not with increased alcohol intake (P = 0.10. At the second examination 10 years later, 56% of participants had lost and 44% gained telomere length with a mean loss of 193 basepairs. Change in leukocyte telomere length during 10 years was associated inversely with baseline telomere length (P<1 × 10(-300 and age at baseline (P = 1 × 10(-27, but not with baseline or 10-year inter-observational tobacco consumption, body weight, physical activity, or alcohol intake. Prospectively during a further 10 years follow-up after the second examination, quartiles of telomere length change did not associate with risk of all-cause mortality, cancer, chronic obstructive pulmonary disease, diabetes mellitus, ischemic cerebrovascular disease, or ischemic heart disease. In conclusion, smoking, increased body weight, and physical inactivity were associated with short telomere length cross-sectionally, but not with telomere length change during 10 years observation, and alcohol intake was associated with neither. Also, change in telomere length did not associate prospectively with mortality or morbidity in the general population.

  12. Measurement of Long Baseline Neutrino Oscillations and Improvements from Deep Learning

    Energy Technology Data Exchange (ETDEWEB)

    Psihas, Fernanda [Indiana U.

    2018-01-01

    NOvA is a long-baseline neutrino oscillation experiment which measures the oscillation of muon neutrinos from the NuMI beam at Fermilab after they travel through the Earth for 810 km. In this dissertation I describe the operations and monitoring of the detectors which make it possible to record over 98% of the delivered neutrino beam. I also present reconstruction and identification techniques using deep convolutional neural networks (CNNs), which are applicable to multiple analyses. Lastly, I detail the oscillation analyses in the $\

  13. Power analysis for multivariate and repeated measures designs: a flexible approach using the SPSS MANOVA procedure.

    Science.gov (United States)

    D'Amico, E J; Neilands, T B; Zambarano, R

    2001-11-01

    Although power analysis is an important component in the planning and implementation of research designs, it is often ignored. Computer programs for performing power analysis are available, but most have limitations, particularly for complex multivariate designs. An SPSS procedure is presented that can be used for calculating power for univariate, multivariate, and repeated measures models with and without time-varying and time-constant covariates. Three examples provide a framework for calculating power via this method: an ANCOVA, a MANOVA, and a repeated measures ANOVA with two or more groups. The benefits and limitations of this procedure are discussed.

  14. The repeatability of interleukin-6, tumor necrosis factor-alpha, and C-reactive protein in COPD patients over one year

    DEFF Research Database (Denmark)

    Kolsum, Umme; Roy, Kay; Starkey, Cerys

    2009-01-01

    BACKGROUND: Many of the systemic manifestations of chronic obstructive pulmonary disease (COPD) are mediated through increased systemic levels of inflammatory proteins. We assessed the long term repeatability of interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), and C-reactive protein......(i)) and the Bland-Altman method. Pearson correlations were used to determine the relationships between the systemic markers at both visits. RESULTS: There was moderate repeatability with a very high degree of statistical significance (p...... (CRP) over one year and examined the relationships between these systemic markers in COPD. METHODS: Fifty-eight stable COPD patients completed a baseline and one-year visit. Serum IL-6, plasma CRP, and plasma TNF-alpha were measured. Repeatability was expressed by intraclass correlation coefficient (R...

  15. The repeatability of interleukin-6, tumor necrosis factor-alpha, and C-reactive protein in COPD patients over one year

    DEFF Research Database (Denmark)

    Kolsum, Umme; Roy, Kay; Starkey, Cerys

    2009-01-01

    BACKGROUND: Many of the systemic manifestations of chronic obstructive pulmonary disease (COPD) are mediated through increased systemic levels of inflammatory proteins. We assessed the long term repeatability of Interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), and C-reactive protein......(i)) and the Bland-Altman method. Pearson correlations were used to determine the relationships between the systemic markers at both visits. RESULTS: There was moderate repeatability with a very high degree of statistical significance (p...... (CRP) over one year and examined the relationships between these systemic markers in COPD. METHODS: Fifty-eight stable COPD patients completed a baseline and one-year visit. Serum IL-6, plasma CRP, and plasma TNF-alpha were measured. Repeatability was expressed by intraclass correlation coefficient (R...

  16. Repeated assessment of orthotopic glioma pO2 by multi-site EPR oximetry: A technique with the potential to guide therapeutic optimization by repeated measurements of oxygen

    Science.gov (United States)

    Khan, Nadeem; Mupparaju, Sriram; Hou, Huagang; Williams, Benjamin B.; Swartz, Harold

    2011-01-01

    Tumor hypoxia plays a vital role in therapeutic resistance. Consequently, measurements of tumor pO2 could be used to optimize the outcome of oxygen-dependent therapies, such as, chemoradiation. However, the potential optimizations are restricted by the lack of methods to repeatedly and quantitatively assess tumor pO2 during therapies, particularly in gliomas. We describe the procedures for repeated measurements of orthotopic glioma pO2 by multi-site electron paramagnetic resonance (EPR) oximetry. This oximetry approach provides simultaneous measurements of pO2 at more than one site in the glioma and contralateral cerebral tissue. The pO2 of intracerebral 9L, C6, F98 and U251 tumors, as well as contralateral brain, were measured repeatedly for five consecutive days. The 9L glioma was well oxygenated with pO2 of 27 - 36 mm Hg, while C6, F98 and U251 glioma were hypoxic with pO2 of 7 - 12 mm Hg. The potential of multi-site EPR oximetry to assess temporal changes in tissue pO2 was investigated in rats breathing 100% O2. A significant increase in F98 tumor and contralateral brain pO2 was observed on day 1 and day 2, however, glioma oxygenation declined on subsequent days. In conclusion, EPR oximetry provides the capability to repeatedly assess temporal changes in orthotopic glioma pO2. This information could be used to test and optimize the methods being developed to modulate tumor hypoxia. Furthermore, EPR oximetry could be potentially used to enhance the outcome of chemoradiation by scheduling treatments at times of increase in glioma pO2. PMID:22079559

  17. Counterbalancing and Other Uses of Repeated-Measures Latin-Square Designs: Analyses and Interpretations.

    Science.gov (United States)

    Reese, Hayne W.

    1997-01-01

    Recommends that when repeated-measures Latin-square designs are used to counterbalance treatments across a procedural variable or to reduce the number of treatment combinations given to each participant, effects be analyzed statistically, and that in all uses, researchers consider alternative interpretations of the variance associated with the…

  18. UK 2009-2010 repeat station report

    Directory of Open Access Journals (Sweden)

    Thomas J.G. Shanahan

    2013-03-01

    Full Text Available The British Geological Survey is responsible for conducting the UK geomagnetic repeat station programme. Measurements made at the UK repeat station sites are used in conjunction with the three UK magnetic observatories: Hartland, Eskdalemuir and Lerwick, to produce a regional model of the local field each year. The UK network of repeat stations comprises 41 stations which are occupied at approximately 3-4 year intervals. Practices for conducting repeat station measurements continue to evolve as advances are made in survey instrumentation and as the usage of the data continues to change. Here, a summary of the 2009 and 2010 UK repeat station surveys is presented, highlighting the measurement process and techniques, density of network, reduction process and recent results.

  19. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  20. Optimally Repeatable Kinetic Model Variant for Myocardial Blood Flow Measurements with 82Rb PET

    Directory of Open Access Journals (Sweden)

    Adrian F. Ocneanu

    2017-01-01

    Full Text Available Purpose. Myocardial blood flow (MBF quantification with Rb82 positron emission tomography (PET is gaining clinical adoption, but improvements in precision are desired. This study aims to identify analysis variants producing the most repeatable MBF measures. Methods. 12 volunteers underwent same-day test-retest rest and dipyridamole stress imaging with dynamic Rb82 PET, from which MBF was quantified using 1-tissue-compartment kinetic model variants: (1 blood-pool versus uptake region sampled input function (Blood/Uptake-ROI, (2 dual spillover correction (SOC-On/Off, (3 right blood correction (RBC-On/Off, (4 arterial blood transit delay (Delay-On/Off, and (5 distribution volume (DV constraint (Global/Regional-DV. Repeatability of MBF, stress/rest myocardial flow reserve (MFR, and stress/rest MBF difference (ΔMBF was assessed using nonparametric reproducibility coefficients (RPCnp = 1.45 × interquartile range. Results. MBF using SOC-On, RVBC-Off, Blood-ROI, Global-DV, and Delay-Off was most repeatable for combined rest and stress: RPCnp = 0.21 mL/min/g (15.8%. Corresponding MFR and ΔMBF RPCnp were 0.42 (20.2% and 0.24 mL/min/g (23.5%. MBF repeatability improved with SOC-On at stress (p<0.001 and tended to improve with RBC-Off at both rest and stress (p<0.08. DV and ROI did not significantly influence repeatability. The Delay-On model was overdetermined and did not reliably converge. Conclusion. MBF and MFR test-retest repeatability were the best with dual spillover correction, left atrium blood input function, and global DV.

  1. A novel variable baseline visibility detection system and its measurement method

    Science.gov (United States)

    Li, Meng; Jiang, Li-hui; Xiong, Xing-long; Zhang, Guizhong; Yao, JianQuan

    2017-10-01

    As an important meteorological observation instrument, the visibility meter can ensure the safety of traffic operation. However, due to the optical system contamination as well as sample error, the accuracy and stability of the equipment are difficult to meet the requirement in the low-visibility environment. To settle this matter, a novel measurement equipment was designed based upon multiple baseline, which essentially acts as an atmospheric transmission meter with movable optical receiver, applying weighted least square method to process signal. Theoretical analysis and experiments in real atmosphere environment support this technique.

  2. Assessment of local GNSS baselines at co-location sites

    Science.gov (United States)

    Herrera Pinzón, Iván; Rothacher, Markus

    2018-01-01

    As one of the major contributors to the realisation of the International Terrestrial Reference System (ITRS), the Global Navigation Satellite Systems (GNSS) are prone to suffer from irregularities and discontinuities in time series. While often associated with hardware/software changes and the influence of the local environment, these discrepancies constitute a major threat for ITRS realisations. Co-located GNSS at fundamental sites, with two or more available instruments, provide the opportunity to mitigate their influence while improving the accuracy of estimated positions by examining data breaks, local biases, deformations, time-dependent variations and the comparison of GNSS baselines with existing local tie measurements. With the use of co-located GNSS data from a subset sites of the International GNSS Service network, this paper discusses a global multi-year analysis with the aim of delivering homogeneous time series of coordinates to analyse system-specific error sources in the local baselines. Results based on the comparison of different GNSS-based solutions with the local survey ties show discrepancies of up to 10 mm despite GNSS coordinate repeatabilities at the sub-mm level. The discrepancies are especially large for the solutions using the ionosphere-free linear combination and estimating tropospheric zenith delays, thus corresponding to the processing strategy used for global solutions. Snow on the antennas causes further problems and seasonal variations of the station coordinates. These demonstrate the need for a permanent high-quality monitoring of the effects present in the short GNSS baselines at fundamental sites.

  3. Measuring Starlight Deflection during the 2017 Eclipse: Repeating the Experiment that made Einstein Famous

    Science.gov (United States)

    Bruns, Donald

    2016-05-01

    In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.

  4. Brachial artery responses to ambient pollution, temperature, and humidity in people with type 2 diabetes: a repeated-measures study.

    Science.gov (United States)

    Zanobetti, Antonella; Luttmann-Gibson, Heike; Horton, Edward S; Cohen, Allison; Coull, Brent A; Hoffmann, Barbara; Schwartz, Joel D; Mittleman, Murray A; Li, Yongsheng; Stone, Peter H; de Souza, Celine; Lamparello, Brooke; Koutrakis, Petros; Gold, Diane R

    2014-03-01

    Extreme weather and air pollution are associated with increased cardiovascular risk in people with diabetes. In a population with diabetes, we conducted a novel assessment of vascular brachial artery responses both to ambient pollution and to weather (temperature and water vapor pressure, a measure of humidity). Sixty-four 49- to 85-year-old Boston residents with type 2 diabetes completed up to five study visits (279 repeated measures). Brachial artery diameter (BAD) was measured by ultrasound before and after brachial artery occlusion [i.e., flow-mediated dilation (FMD)] and before and after nitroglycerin-mediated dilation (NMD). Ambient concentrations of fine particulate mass (PM2.5), black carbon (BC), organic carbon (OC), elemental carbon, particle number, and sulfate were measured at our monitoring site; ambient concentrations of carbon monoxide, nitrogen dioxide, and ozone were obtained from state monitors. Particle exposure in the home and during each trip to the clinic (home/trip exposure) was measured continuously and as a 5-day integrated sample. We used linear models with fixed effects for participants, adjusting for date, season, temperature, and water vapor pressure on the day of each visit, to estimate associations between our outcomes and interquartile range increases in exposure. Baseline BAD was negatively associated with particle pollution, including home/trip-integrated BC (-0.02 mm; 95% CI: -0.04, -0.003, for a 0.28 μg/m3 increase in BC), OC (-0.08 mm; 95% CI: -0.14, -0.03, for a 1.61 μg/m3 increase) as well as PM2.5, 5-day average ambient PM2.5, and BC. BAD was positively associated with ambient temperature and water vapor pressure. However, exposures were not consistently associated with FMD or NMD. Brachial artery diameter, a predictor of cardiovascular risk, decreased in association with particle pollution and increased in association with ambient temperature in our study population of adults with type 2 diabetes. Zanobetti A, Luttmann

  5. Sustained attention performance during sleep deprivation associates with instability in behavior and physiologic measures at baseline.

    Science.gov (United States)

    Chua, Eric Chern-Pin; Yeo, Sing-Chen; Lee, Ivan Tian-Guang; Tan, Luuan-Chin; Lau, Pauline; Cai, Shiwei; Zhang, Xiaodong; Puvanendran, Kathiravelu; Gooley, Joshua J

    2014-01-01

    To identify baseline behavioral and physiologic markers that associate with individual differences in sustained attention during sleep deprivation. In a retrospective study, ocular, electrocardiogram, and electroencephalogram (EEG) measures were compared in subjects who were characterized as resilient (n = 15) or vulnerable (n = 15) to the effects of total sleep deprivation on sustained attention. Chronobiology and Sleep Laboratory, Duke-NUS Graduate Medical School Singapore. Healthy volunteers aged 22-32 years from the general population. Subjects were kept awake for at least 26 hours under constant environmental conditions. Every 2 hours, sustained attention was assessed using a 10-minute psychomotor vigilance task (PVT). During baseline sleep and recovery sleep, EEG slow wave activity was similar in resilient versus vulnerable subjects, suggesting that individual differences in vulnerability to sleep loss were not related to differences in homeostatic sleep regulation. Rather, irrespective of time elapsed since wake, subjects who were vulnerable to sleep deprivation exhibited slower and more variable PVT response times, lower and more variable heart rate, and higher and more variable EEG spectral power in the theta frequency band (6.0-7.5 Hz). Performance decrements in sustained attention during sleep deprivation associate with instability in behavioral and physiologic measures at baseline. Small individual differences in sustained attention that are present at baseline are amplified during prolonged wakefulness, thus contributing to large between-subjects differences in performance and sleepiness.

  6. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    International Nuclear Information System (INIS)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-01-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of [ 3 H]Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in [14C]iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress [an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures], although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results

  7. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-06-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of (/sup 3/H)Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in (14C)iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress (an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures), although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results.

  8. Integrated planning: A baseline development perspective

    International Nuclear Information System (INIS)

    Clauss, L.; Chang, D.

    1994-01-01

    The FEMP Baseline establishes the basis for integrating environmental activity technical requirements with their cost and schedule elements. The result is a path forward to successfully achieving the FERMCO mission. Specific to cost management, the FEMP Baseline has been incorporate into the FERMCO Project Control System (PCS) to provide a time-phased budget plan against which contractor performance is measured with an earned value management system. The result is the Performance Measurement Baseline (PMB), an important tool for keeping cost under control

  9. Use of Repeated Blood Pressure and Cholesterol Measurements to Improve Cardiovascular Disease Risk Prediction

    DEFF Research Database (Denmark)

    Paige, Ellie; Barrett, Jessica; Pennells, Lisa

    2017-01-01

    The added value of incorporating information from repeated blood pressure and cholesterol measurements to predict cardiovascular disease (CVD) risk has not been rigorously assessed. We used data on 191,445 adults from the Emerging Risk Factors Collaboration (38 cohorts from 17 countries with data...

  10. Comparison of Repeated Measurement Design and Mixed Models in Evaluation of the Entonox Effect on Labor Pain

    Directory of Open Access Journals (Sweden)

    Nasim Karimi

    2017-01-01

    Full Text Available Background & objectives: In many medical studies, the response variable is measured repeatedly over time to evaluate the treatment effect that is known as longitudinal study. The analysis method for this type of data is repeated measures ANOVA that uses only one correlation structure and the results are not valid with inappropriate correlation structure. To avoid this problem, a convenient alternative is mixed models. So, the aim of this study was to compare of mixed and repeated measurement models for examination of the Entonox effect on the labor pain. Methods: This experimental study was designed to compare the effect of Entonox and oxygen inhalation on pain relief between two groups. Data were analyzed using repeated measurement and mixed models with different correlation structures. Selection and comparison of proper correlation structures performed using Akaike information criterion, Bayesian information criterion and restricted log-likelihood. Data were analyzed using SPSS-22. Results: Results of our study showed that all variables containing analgesia methods, labor duration of the first and second stages, and time were significant in these tests. In mixed model, heterogeneous first-order autoregressive, first-order autoregressive, heterogeneous Toeplitz and unstructured correlation structures were recognized as the best structures. Also, all variables were significant in these structures. Unstructured variance covariance matrix was recognized as the worst structure and labor duration of the first and second stages was not significant in this structure. Conclusions: This study showed that the Entonox inhalation has a significant effect on pain relief in primiparous and it is confirmed by all of the models.

  11. Impact of repeated daily exposure to intermittent hypoxia and mild sustained hypercapnia on apnea severity.

    Science.gov (United States)

    Yokhana, Sanar S; Gerst, David G; Lee, Dorothy S; Badr, M Safwan; Qureshi, Tabarak; Mateika, Jason H

    2012-02-01

    We examined whether exposure to intermittent hypoxia (IH) during wakefulness impacted on the apnea/hypopnea index (AHI) during sleep in individuals with sleep apnea. Participants were exposed to twelve 4-min episodes of hypoxia in the presence of sustained mild hypercapnia each day for 10 days. A control group was exposed to sustained mild hypercapnia for a similar duration. The intermittent hypoxia protocol was completed in the evening on day 1 and 10 and was followed by a sleep study. During all sleep studies, the change in esophageal pressure (ΔPes) from the beginning to the end of an apnea and the tidal volume immediately following apneic events were used to measure respiratory drive. Following exposure to IH on day 1 and 10, the AHI increased above baseline measures (day 1: 1.95 ± 0.42 fraction of baseline, P ≤ 0.01, vs. day 10: 1.53 ± 0.24 fraction of baseline, P < 0.06). The indexes were correlated to the hypoxic ventilatory response (HVR) measured during the IH protocol but were not correlated to the magnitude of ventilatory long-term facilitation (vLTF). Likewise, ΔPes and tidal volume measures were greater on day 1 and 10 compared with baseline (ΔPes: -8.37 ± 0.84 vs. -5.90 ± 1.30 cmH(2)0, P ≤ 0.04; tidal volume: 1,193.36 ± 101.85 vs. 1,015.14 ± 119.83 ml, P ≤ 0.01). This was not the case in the control group. Interestingly, the AHI on day 10 (0.78 ± 0.13 fraction of baseline, P ≤ 0.01) was significantly less than measures obtained during baseline and day 1 in the mild hypercapnia control group. We conclude that enhancement of the HVR initiated by exposure to IH may lead to increases in the AHI during sleep and that initiation of vLTF did not appear to impact on breathing stability. Lastly, our results suggest that repeated daily exposure to mild sustained hypercapnia may lead to a decrease in breathing events.

  12. Ocular surface sensitivity repeatability with Cochet-Bonnet esthesiometer.

    Science.gov (United States)

    Chao, Cecilia; Stapleton, Fiona; Badarudin, Ezailina; Golebiowski, Blanka

    2015-02-01

    To determine the repeatability of ocular surface threshold measurements using the Cochet-Bonnet esthesiometer on the same day and 3 months apart. Two separate studies were conducted to determine the repeatability of ocular surface threshold measurements made on the same day (n = 20 subjects) and 3 months apart (n = 29 subjects). The Cochet-Bonnet esthesiometer was used to measure corneal and inferior conjunctival thresholds using the ascending method of limits. The pressure exerted by the Cochet-Bonnet esthesiometer was determined using an analytical balance, for both the 0.08- and 0.12-mm-diameter filaments. This calibration was then used to convert filament length measurements to pressure. Repeatability was determined using a Bland and Altman analysis. The pressure exerted at each filament length differed between the two filament diameters. The measured pressure also differed from values provided by the manufacturer. Repeatability of threshold measurements at the central cornea was shown to be good, with better repeatability for same-day measurements (coefficient of repeatability [CoR] = ±0.23 g/mm²) than for those 3 months apart (CoR = ±0.52 g/mm²). Threshold measurements at the inferior conjunctiva, in contrast, were poorly repeatable (CoR = ±12.78 g/mm²). Cochet-Bonnet esthesiometry is repeatable when performed on the central cornea on the same day and 3 months apart, but this instrument is not recommended for conjunctival threshold measurements.

  13. REPEATED MEASURES ANALYSIS OF CHANGES IN PHOTOSYNTHETIC EFFICIENCY IN SOUR CHERRY DURING WATER DEFICIT

    Directory of Open Access Journals (Sweden)

    Marija Viljevac

    2012-06-01

    Full Text Available The objective of this study was to investigate changes in photosynthetic efficiency applying repeated measures ANOVA using the photosynthetic performance index (PIABS of the JIP-test as a vitality parameter in seven genotypes of sour cherry (Prunus cerasus, L. during 10 days of continuous water deficit. Both univariate and multivariate ANOVA repeated measures revealed highly significant time effect (Days and its subsequent interactions with genotype and water deficit. However, the multivariate Pillai’s trace test detected the interaction Time × Genotype × Water deficit as not significant. According to the Tukey’s Studentized Range (HSD test, differences between the control and genotypes exposed to water stress became significant on the fourth day of the experiment, indicating that the plants on the average, began to lose their photosynthetic efficiency four days after being exposed to water shortage. It corroborates previous findings in other species that PIABS is very sensitive tool for detecting drought stress.

  14. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine.

    Science.gov (United States)

    Breen, Alexander; Breen, Alan

    2016-07-01

    Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  16. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  17. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy.

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-07-01

    To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)-associated retinopathy. Twelve patients with STGD (aged 9-52 years) and eight with RPGR-associated retinopathy (aged 11-31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions.

  18. The Vestibular Effects of Repeated Low-Level Blasts.

    Science.gov (United States)

    Littlefield, Philip D; Pinto, Robin L; Burrows, Holly L; Brungart, Douglas S

    2016-01-01

    The objective of this study was to use a prospective cohort of United States Marine Corps (USMC) instructors to identify any acute or long-term vestibular dysfunction following repeated blast exposures during explosive breaching training. They were assessed in clinic and on location during training at the USMC Methods of Entry School, Quantico, VA. Subjects received comprehensive baseline vestibular assessments and these were repeated in order to identify longitudinal changes. They also received shorter assessments immediately following blast exposure in order to identify acute findings. The main outcome measures were the Neurobehavioral Symptom Inventory, vestibular Visual Analog Scale (VAS) of subjective vestibular function, videonystagmography (VNG), vestibular evoked myogenic potentials (VEMP), rotary chair (including the unilateral centrifugation test), computerized dynamic posturography, and computerized dynamic visual acuity. A total of 11 breachers and 4 engineers were followed for up to 17 months. No acute effects or longitudinal deteriorations were identified, but there were some interesting baseline group differences. Upbeat positional nystagmus was common, and correlated (p<0.005) with a history of mild traumatic brain injury (mTBI). Several instructors had abnormally short low-frequency phase leads on rotary chair testing. This study evaluated breaching instructors over a longer test period than any other study, and the results suggest that this population appears to be safe from a vestibular standpoint at the current exposure levels. Upbeat positional nystagmus correlated with a history of mTBI in this population, and this has not been described elsewhere. The data trends also suggest that this nystagmus could be an acute blast effect. However, the reasons for the abnormally short phase leads seen in rotary chair testing are unclear at this time. Further investigation seems warranted.

  19. Repeated absolute gravity measurements for monitoring slow intraplate vertical deformation in Western Europe

    Science.gov (United States)

    Van Camp, M. J.; de Viron, O.; Scherneck, H.; Hinzen, K. G.; Williams, S. D.; Lecocq, T.; Quinif, Y.; Camelbeeck, T.

    2011-12-01

    In continental plate interiors, ground surface movements are at the limit of the noise level and close to or below the accuracy of current geodetic techniques. Absolute gravity measurements are valuable to quantify slow vertical movements, as this instrument is drift free and, unlike GPS, independent of the terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformation in the area. The AG measurements, repeated once or twice a year, can resolve elusive gravity changes with a precision better than 3.7 nm/s2/yr (95% confidence interval) after 11 years, even in difficult conditions. After 8-15 years (depending on the station), we find that the gravity rates of change lie in the [-3.1, 8.1] nm/s2/yr interval and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. After correcting for the GIA, the inferred gravity rates and consequently, the vertical land movements, reduce to zero within the uncertainty level at all stations except Jülich (due to man-induced subsidence) and Sohier (possibly, an artefact due to the shortness of the time series at that station).

  20. Repeatability of Maternal Report on Prenatal, Perinatal and Early Postnatal Factors

    DEFF Research Database (Denmark)

    Hermann, Diana; Suling, Marc; Reisch, Lucia

    2011-01-01

    To investigate the repeatability of maternal self-reported prenatal, perinatal and early postnatal factors within the IDEFICS (Identification and prevention of dietary- and lifestyle-induced health effects in children and infants) study. Design: Data are from the baseline survey of the longitudin...

  1. Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

    Science.gov (United States)

    Beaton, K. H.; Bloomberg, J. J.

    2014-01-01

    One of the greatest challenges surrounding adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. Such knowledge could guide individually customized countermeasures, which would enable more efficient use of crew time, both preflight and inflight, and provide better outcomes. The primary goal of this project is to look for a baseline performance metric that can forecast sensorimotor adaptability without exposure to an adaptive stimulus. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations in motor performance, as a predictor of individual sensorimotor adaptive capabilities. To-date, a strong relationship has been found between baseline inter-trial correlations and adaptability in two oculomotor systems. For this project, we will explore an analogous predictive mechanism in the locomotion system. METHODS: Baseline Inter-trial Correlations: Inter-trial correlations specify the relationships among repeated trials of a given task that transpire as a consequence of correcting for previous performance errors over multiple timescales. We can quantify the strength of inter-trial correlations by measuring the decay of the autocorrelation function (ACF), which describes how rapidly information from past trials is "forgotten." Processes whose ACFs decay more slowly exhibit longer-term inter-trial correlations (longer memory processes), while processes whose ACFs decay more rapidly exhibit shorterterm inter-trial correlations (shorter memory processes). Longer-term correlations reflect low-frequency activity, which is more easily

  2. Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions.

    Science.gov (United States)

    Muthalib, Makii; Millet, Guillaume Y; Quaresima, Valentina; Nosaka, Kazunori

    2010-01-01

    We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%); however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

  3. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-01-01

    Purpose To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)–associated retinopathy. Methods Twelve patients with STGD (aged 9–52 years) and eight with RPGR-associated retinopathy (aged 11–31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). Results For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Conclusions Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions. PMID:28738413

  4. Analyzing repeated measures data on individuals nested within groups: accounting for dynamic group effects.

    Science.gov (United States)

    Bauer, Daniel J; Gottfredson, Nisha C; Dean, Danielle; Zucker, Robert A

    2013-03-01

    Researchers commonly collect repeated measures on individuals nested within groups such as students within schools, patients within treatment groups, or siblings within families. Often, it is most appropriate to conceptualize such groups as dynamic entities, potentially undergoing stochastic structural and/or functional changes over time. For instance, as a student progresses through school, more senior students matriculate while more junior students enroll, administrators and teachers may turn over, and curricular changes may be introduced. What it means to be a student within that school may thus differ from 1 year to the next. This article demonstrates how to use multilevel linear models to recover time-varying group effects when analyzing repeated measures data on individuals nested within groups that evolve over time. Two examples are provided. The 1st example examines school effects on the science achievement trajectories of students, allowing for changes in school effects over time. The 2nd example concerns dynamic family effects on individual trajectories of externalizing behavior and depression. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  5. Repeat syphilis has a different immune response compared with initial syphilis: an analysis of biomarker kinetics in two cohorts.

    Science.gov (United States)

    Kenyon, Chris; Tsoumanis, Achilleas; Osbak, Kara; Van Esbroeck, Marjan; Florence, Eric; Crucitti, Tania; Kestens, Luc

    2017-10-11

    We aimed to asses if there are differences in the clinical presentation and immune response of repeat as compared with initial syphilis. Prospective study: we prospectively recruited all patients with a new diagnosis of syphilis and tested their plasma for a range of cytochemokines and rapid plasma reagin (RPR) at baseline pretreatment and 6 months following therapy. Retrospective study: we compared RPR assay response kinetics between initial and repeat syphilis in persons attending our HIV/STI clinic from 1993 to 2016. Prospective study: a total of 91 individuals, 36 with initial syphilis and 55 with repeat syphilis, were included in the study. At baseline visit, those with initial syphilis were more likely to be symptomatic and have higher levels of interleukin-10 than repeaters. At baseline, median RPR titres were higher in the repeat than the initial infection groups. Repeaters were less likely than those with initial infections to serorevert to a negative RPR and be serofast (<4-fold RPR titre decline) at 6 months.Retrospective study: syphilis was diagnosed in 1027/43 870 individuals tested. At diagnosis, repeaters had higher RPR titres and a stepwise increase in RPR titre with number of syphilis episodes. They had a different RPR test response kinetic: they were less likely to be serofast and to serorevert than initial syphilis at 6 and 12 months. No individuals with four or more previous episodes of syphilis seroreverted. Repeat syphilis has a different clinical presentation and immunological response to initial infection. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Comparison of CFD Predictions of the TCA Baseline

    Science.gov (United States)

    Cappuccio, Gelsomina

    1999-01-01

    The computational fluid dynamics (CFD) comparisons being presented are compared to each other and to wind tunnel (WT) data on the baseline TCA. Some of the CFD computations were done prior to the tests and others later. Only force data (CL vs CD) from CFD will be presented as part of this report. The WT data presented comes from the testing of the baseline TCA in the Langley Unitary Plan Wind Tunnel (UPWT), Test Section #2. There are 2 sets of wind tunnel data being presented: one from test 1671 of model 2a (flapped wing) and the other from test 1679 of model 2b (solid wing). Most of the plots show only one run from each of the WT tests per configuration. But many repeat runs were taken during the tests. The WT repeat runs showed an uncertainty in the drag of +/- 0.5 count. There were times when the uncertainty in drag was better, +/- 0.25 count. Test 1671 data was of forces and pressures measured from model 2a. The wing had cutouts for installing various leading and trailing edge flaps at lower Mach numbers. The internal duct of the nacelles are not designed and fabricated as defined in the outer mold lines (OML) iges file. The internal duct was fabricated such that a linear transition occurs from the inlet to exhaust. Whereas, the iges definition has a constant area internal duct that quickly transitions from the inlet to exhaust cross sectional shape. The nacelle internal duct was fabricated, the way described, to save time and money. The variation in the cross sectional area is less than 1% from the iges definition. The nacelles were also installed with and without fairings. Fairings are defined as the build up of the nacelles on the upper wing surface so that the nacelles poke through the upper surface as defined in the OML iges file. Test 1679 data was of forces measured from model 2a and 2b. The wing for model 2b was a solid wing. The nacelles were built the same way as for model 2a, except for the nacelle base pressure installation. The nacelles were only

  7. (In)Consistencies in Responses to Sodium Bicarbonate Supplementation: A Randomised, Repeated Measures, Counterbalanced and Double-Blind Study.

    Science.gov (United States)

    Froio de Araujo Dias, Gabriela; da Eira Silva, Vinicius; de Salles Painelli, Vitor; Sale, Craig; Giannini Artioli, Guilherme; Gualano, Bruno; Saunders, Bryan

    2015-01-01

    Intervention studies do not account for high within-individual variation potentially compromising the magnitude of an effect. Repeat administration of a treatment allows quantification of individual responses and determination of the consistency of responses. We determined the consistency of metabolic and exercise responses following repeated administration of sodium bicarbonate (SB). 15 physically active males (age 25±4 y; body mass 76.0±7.3 kg; height 1.77±0.05 m) completed six cycling capacity tests at 110% of maximum power output (CCT110%) following ingestion of either 0.3 g∙kg-1BM of SB (4 trials) or placebo (PL, 2 trials). Blood pH, bicarbonate, base excess and lactate were determined at baseline, pre-exercise, post-exercise and 5-min post-exercise. Total work done (TWD) was recorded as the exercise outcome. SB supplementation increased blood pH, bicarbonate and base excess prior to every trial (all p ≤ 0.001); absolute changes in pH, bicarbonate and base excess from baseline to pre-exercise were similar in all SB trials (all p > 0.05). Blood lactate was elevated following exercise in all trials (p ≤ 0.001), and was higher in some, but not all, SB trials compared to PL. TWD was not significantly improved with SB vs. PL in any trial (SB1: +3.6%; SB2 +0.3%; SB3: +2.1%; SB4: +6.7%; all p > 0.05), although magnitude-based inferences suggested a 93% likely improvement in SB4. Individual analysis showed ten participants improved in at least one SB trial above the normal variation of the test although five improved in none. The mechanism for improved exercise with SB was consistently in place prior to exercise, although this only resulted in a likely improvement in one trial. SB does not consistently improve high intensity cycling capacity, with results suggesting that caution should be taken when interpreting the results from single trials as to the efficacy of SB supplementation. ClinicalTrials.gov NCT02474628.

  8. (InConsistencies in Responses to Sodium Bicarbonate Supplementation: A Randomised, Repeated Measures, Counterbalanced and Double-Blind Study.

    Directory of Open Access Journals (Sweden)

    Gabriela Froio de Araujo Dias

    Full Text Available Intervention studies do not account for high within-individual variation potentially compromising the magnitude of an effect. Repeat administration of a treatment allows quantification of individual responses and determination of the consistency of responses. We determined the consistency of metabolic and exercise responses following repeated administration of sodium bicarbonate (SB.15 physically active males (age 25±4 y; body mass 76.0±7.3 kg; height 1.77±0.05 m completed six cycling capacity tests at 110% of maximum power output (CCT110% following ingestion of either 0.3 g∙kg-1BM of SB (4 trials or placebo (PL, 2 trials. Blood pH, bicarbonate, base excess and lactate were determined at baseline, pre-exercise, post-exercise and 5-min post-exercise. Total work done (TWD was recorded as the exercise outcome.SB supplementation increased blood pH, bicarbonate and base excess prior to every trial (all p ≤ 0.001; absolute changes in pH, bicarbonate and base excess from baseline to pre-exercise were similar in all SB trials (all p > 0.05. Blood lactate was elevated following exercise in all trials (p ≤ 0.001, and was higher in some, but not all, SB trials compared to PL. TWD was not significantly improved with SB vs. PL in any trial (SB1: +3.6%; SB2 +0.3%; SB3: +2.1%; SB4: +6.7%; all p > 0.05, although magnitude-based inferences suggested a 93% likely improvement in SB4. Individual analysis showed ten participants improved in at least one SB trial above the normal variation of the test although five improved in none.The mechanism for improved exercise with SB was consistently in place prior to exercise, although this only resulted in a likely improvement in one trial. SB does not consistently improve high intensity cycling capacity, with results suggesting that caution should be taken when interpreting the results from single trials as to the efficacy of SB supplementation.ClinicalTrials.gov NCT02474628.

  9. Fixed or adapted conditioning intensity for repeated conditioned pain modulation.

    Science.gov (United States)

    Hoegh, M; Petersen, K K; Graven-Nielsen, T

    2017-12-29

    Aims Conditioned pain modulation (CPM) is used to assess descending pain modulation through a test stimulation (TS) and a conditioning stimulation (CS). Due to potential carry-over effects, sequential CPM paradigms might alter the intensity of the CS, which potentially can alter the CPM-effect. This study aimed to investigate the difference between a fixed and adaptive CS intensity on CPM-effect. Methods On the dominant leg of 20 healthy subjects the cuff pressure detection threshold (PDT) was recorded as TS and the pain tolerance threshold (PTT) was assessed on the non-dominant leg for estimating the CS. The difference in PDT before and during CS defined the CPM-effect. The CPM-effect was assessed four times using a CS with intensities of 70% of baseline PTT (fixed) or 70% of PTT measured throughout the session (adaptive). Pain intensity of the conditioning stimulus was assessed on a numeric rating scale (NRS). Data were analyzed with repeated-measures ANOVA. Results No difference was found comparing the four PDTs assessed before CSs for the fixed and the adaptive paradigms. The CS pressure intensity for the adaptive paradigm was increasing during the four repeated assessments (P CPM-effect was higher using the fixed condition compared with the adaptive condition (P CPM paradigms using a fixed conditioning stimulus produced an increased CPM-effect compared with adaptive and increasing conditioning intensities.

  10. California Baseline Ozone Transport Study (CABOTS): Ozonesonde Measurements

    Science.gov (United States)

    Eiserloh, A. J., Jr.; Chiao, S.; Spitze, J.; Cauley, S.; Clark, J.; Roberts, M.

    2016-12-01

    Because the EPA recently lowered the ambient air quality standard for the 8-hr average of ozone (O3) to70 ppbv, California must continue to achieve significant reductions in ozone precursor emissions and prepare for new State Implementation Plans (SIP) to demonstrate how ground-level ambient ozone will be reduced below the new health-based standard. Prior studies suggest that background levels of ozone traveling across the Pacific Ocean can significantly influence surface ozone throughout California, particularly during the spring. Evidence has been presented indicating that background levels of ozone continue to increase in the western United States over the recent few decades, implying more ozone exceedances in the future. To better understand the contributions of the external natural and anthropogenic pollution sources as well as atmospheric processes for surface ozone concentrations in California during the spring and summer months, the California Baseline Ozone Transport Study (CABOTS) has been established. One major goal of CABOTS is to implement near daily ozonesonde measurements along the California Coast to quantify background ozone aloft before entering the State during high ozone season. CABOTS has been ongoing from May through August of 2016 launching ozonesondes from Bodega Bay and Half Moon Bay, California. The temporal progression of ozonesonde measurements and subsequent analysis of the data will be discussed with a focus on the contribution of background ozone to surface ozone sites inland as well as likely origins of layers aloft. Comparisons of current ozonesondes versus prior ozonesonde studies of California will also be performed. A few selected cases of high ozone layers moving onshore from different sources will be discussed as well.

  11. Repeated testing improves achievement in a blended learning approach for risk competence training of medical students: results of a randomized controlled trial.

    Science.gov (United States)

    Spreckelsen, C; Juenger, J

    2017-09-26

    Adequate estimation and communication of risks is a critical competence of physicians. Due to an evident lack of these competences, effective training addressing risk competence during medical education is needed. Test-enhanced learning has been shown to produce marked effects on achievements. This study aimed to investigate the effect of repeated tests implemented on top of a blended learning program for risk competence. We introduced a blended-learning curriculum for risk estimation and risk communication based on a set of operationalized learning objectives, which was integrated into a mandatory course "Evidence-based Medicine" for third-year students. A randomized controlled trial addressed the effect of repeated testing on achievement as measured by the students' pre- and post-training score (nine multiple-choice items). Basic numeracy and statistical literacy were assessed at baseline. Analysis relied on descriptive statistics (histograms, box plots, scatter plots, and summary of descriptive measures), bootstrapped confidence intervals, analysis of covariance (ANCOVA), and effect sizes (Cohen's d, r) based on adjusted means and standard deviations. All of the 114 students enrolled in the course consented to take part in the study and were assigned to either the intervention or control group (both: n = 57) by balanced randomization. Five participants dropped out due to non-compliance (control: 4, intervention: 1). Both groups profited considerably from the program in general (Cohen's d for overall pre vs. post scores: 2.61). Repeated testing yielded an additional positive effect: while the covariate (baseline score) exhibits no relation to the post-intervention score, F(1, 106) = 2.88, p > .05, there was a significant effect of the intervention (repeated tests scenario) on learning achievement, F(1106) = 12.72, p blended learning approach can be improved significantly by implementing a test-enhanced learning design, namely repeated testing. As

  12. Intelligence is in the eye of the beholder: investigating repeated IQ measurements in forensic psychiatry.

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-05-01

    A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were computed, and each IQ score was categorized. Additionally, t-tests and regression analyses were performed. Differences of 10 points or more were found in 66% of the cases comparing WAIS-III with RAVEN scores. Fisher's exact test revealed differences between two WAIS-III scores and the WAIS categories. The WAIS-III did not predict other IQs (WAIS or RAVEN) in participants with intellectual disability. This study showed that stability or interchangeability of scores is lacking, especially in individuals with intellectual disability. Caution in interpreting IQ scores is therefore recommended, and the use of the unitary concept of IQ should be discouraged. © 2014 John Wiley & Sons Ltd.

  13. Large short-baseline νμ disappearance

    International Nuclear Information System (INIS)

    Giunti, Carlo; Laveder, Marco

    2011-01-01

    We analyze the LSND, KARMEN, and MiniBooNE data on short-baseline ν μ →ν e oscillations and the data on short-baseline ν e disappearance obtained in the Bugey-3 and CHOOZ reactor experiments in the framework of 3+1 antineutrino mixing, taking into account the MINOS observation of long-baseline ν μ disappearance and the KamLAND observation of very-long-baseline ν e disappearance. We show that the fit of the data implies that the short-baseline disappearance of ν μ is relatively large. We obtain a prediction of an effective amplitude sin 2 2θ μμ > or approx. 0.1 for short-baseline ν μ disappearance generated by 0.2 2 2 , which could be measured in future experiments.

  14. Effects of GABA[subscript A] Modulators on the Repeated Acquisition of Response Sequences in Squirrel Monkeys

    Science.gov (United States)

    Campbell, Una C.; Winsauer, Peter J.; Stevenson, Michael W.; Moerschbaecher, Joseph M.

    2004-01-01

    The present study investigated the effects of positive and negative GABA[subscript A] modulators under three different baselines of repeated acquisition in squirrel monkeys in which the monkeys acquired a three-response sequence on three keys under a second-order fixed-ratio (FR) schedule of food reinforcement. In two of these baselines, the…

  15. Recommendations for analysis of repeated-measures designs: testing and correcting for sphericity and use of manova and mixed model analysis.

    Science.gov (United States)

    Armstrong, Richard A

    2017-09-01

    A common experimental design in ophthalmic research is the repeated-measures design in which at least one variable is a within-subject factor. This design is vulnerable to lack of 'sphericity' which assumes that the variances of the differences among all possible pairs of within-subject means are equal. Traditionally, this design has been analysed using a repeated-measures analysis of variance (RM-anova) but increasingly more complex methods such as multivariate anova (manova) and mixed model analysis (MMA) are being used. This article surveys current practice in the analysis of designs incorporating different factors in research articles published in three optometric journals, namely Ophthalmic and Physiological Optics (OPO), Optometry and Vision Science (OVS), and Clinical and Experimental Optometry (CXO), and provides advice to authors regarding the analysis of repeated-measures designs. Of the total sample of articles, 66% used a repeated-measures design. Of those articles using a repeated-measures design, 59% and 8% analysed the data using RM-anova or manova respectively and 33% used MMA. The use of MMA relative to RM-anova has increased significantly since 2009/10. A further search using terms to select those papers testing and correcting for sphericity ('Mauchly's test', 'Greenhouse-Geisser', 'Huynh and Feld') identified 66 articles, 62% of which were published from 2012 to the present. If the design is balanced without missing data then manova should be used rather than RM-anova as it gives better protection against lack of sphericity. If the design is unbalanced or with missing data then MMA is the method of choice. However, MMA is a more complex analysis and can be difficult to set up and run, and care should be taken first, to define appropriate models to be tested and second, to ensure that sample sizes are adequate. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  16. A Mean-Shift-Based Feature Descriptor for Wide Baseline Stereo Matching

    Directory of Open Access Journals (Sweden)

    Yiwen Dou

    2015-01-01

    Full Text Available We propose a novel Mean-Shift-based building approach in wide baseline. Initially, scale-invariance feature transform (SIFT approach is used to extract relatively stable feature points. As to each matching SIFT feature point, it needs a reasonable neighborhood range so as to choose feature points set. Subsequently, in view of selecting repeatable and high robust feature points, Mean-Shift controls corresponding feature scale. At last, our approach is employed to depth image acquirement in wide baseline and Graph Cut algorithm optimizes disparity information. Compared with the existing methods such as SIFT, speeded up robust feature (SURF, and normalized cross-correlation (NCC, the presented approach has the advantages of higher robustness and accuracy rate. Experimental results on low resolution image and weak feature description in wide baseline confirm the validity of our approach.

  17. Study on the calibration and optimization of double theodolites baseline

    Science.gov (United States)

    Ma, Jing-yi; Ni, Jin-ping; Wu, Zhi-chao

    2018-01-01

    For the double theodolites measurement system baseline as the benchmark of the scale of the measurement system and affect the accuracy of the system, this paper puts forward a method for calibration and optimization of the double theodolites baseline. Using double theodolites to measure the known length of the reference ruler, and then reverse the baseline formula. Based on the error propagation law, the analyses show that the baseline error function is an important index to measure the accuracy of the system, and the reference ruler position, posture and so on have an impact on the baseline error. The optimization model is established and the baseline error function is used as the objective function, and optimizes the position and posture of the reference ruler. The simulation results show that the height of the reference ruler has no effect on the baseline error; the posture is not uniform; when the reference ruler is placed at x=500mm and y=1000mm in the measurement space, the baseline error is the smallest. The experimental results show that the experimental results are consistent with the theoretical analyses in the measurement space. In this paper, based on the study of the placement of the reference ruler, for improving the accuracy of the double theodolites measurement system has a reference value.

  18. Characterisation and measurement of signals generated by DVB-H 'gap-filler' repeaters

    International Nuclear Information System (INIS)

    Baldini, M.; Barellini, A.; Bogi, L.; Licitra, G.; Silvi, A. M.; Zari, A.

    2009-01-01

    DVB-H (Digital Video Broadcasting Hand-held) is the standard developed by DVB Project and approved by ETSI with the aim of providing the reception of DVB signals even in mobility but also data transfers and multimedia services. The introduction and development of the DVB-H system is still ongoing. In this context, this work focuses on the temporal trend of electromagnetic impact of an urban DVB-H repeater (called 'gap-filler') for exposure assessment purposes; it also describes a method for its measurement by means of narrow band instrumental chains. (authors)

  19. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    Science.gov (United States)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  20. Association between psychological measures and brain natriuretic peptide in heart failure patients

    DEFF Research Database (Denmark)

    Brouwers, Corline; Spindler, Helle; Larsen, Mogens Lytken

    2012-01-01

    Scale (HADS), the Beck Depression Inventory (BDI), and the Type D Scale (DS14) were assessed only at baseline. Plasma NT-proBNP levels were measured at baseline and at 9 months. Results: The prevalence of anxiety, depression and Type D personality at baseline was 23.4% (HADS-A), 17.0% (HADS-D), 46.......6% (BDI) and 21.3% (DS14), respectively. At baseline, none of the psychological risk markers were associated with NT-proBNP levels (all ps≥.05). In the subset of patients with scores on psychological risk markers both at baseline and at 9 months there were no association between anxiety (p=0.......44), depression (HADS-D: p=0.90; BDI: p=0.85), and Type D (p=0.63) with NT-proBNP levels using ANOVA for repeated measures. Conclusions: Our findings indicate that measures frequently used in HF to assess psychological risk markers are unconfounded by NT-proBNP. Further studies are warranted that replicate...

  1. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  2. Psychosocial outcomes of Hong Kong Chinese diagnosed with acute coronary syndromes: a prospective repeated measures study.

    Science.gov (United States)

    Chan, Dominic S K; Chau, Janita P C; Chang, Anne M

    2007-08-01

    Western studies have suggested that emotional stress and distress impacted on the morbidity and mortality in people following acute coronary events. Symptoms of anxiety and depression have been associated with re-infarction and death, prolonged recovery and disability and depression may precipitate the client's low self-esteem. This study examined perceived anxiety, depression and self-esteem of Hong Kong Chinese clients diagnosed with acute coronary syndrome (ACS) over a 6-month period following hospital admission. To examine: A prospective, repeated measures design with measures taken on two occasions over a 6-month period; (1) within the 1st week of hospital admission following the onset of ACS and (2) at 6 months follow up. Convenient sample of 182 voluntary consented clients admitted with ACS to a major public hospital in Hong Kong who could communicate in Chinese, complete questionnaires, cognitive intact, and were haemodynamically stable and free from acute chest pain at the time of interview. Baseline data were obtained within 1 week after hospital admission. The follow-up data was collected 6 months after hospital discharge. The Chinese version of the Hospital Anxiety and Depression Scale (HADS), State Self-esteem Scale (SSES), and Rosenberg's Self-Esteem Scale (RSES) were used to assess anxiety and depression, state self-esteem, and trait self-esteem, respectively. Findings suggested gender differences in clients' perception in anxiety, depression and self-esteem. Improvements in clients' perception of these variables were evident over the 6-month period following their acute coronary events. The study confirmed the western notion that psychosocial problems are common among coronary clients and this also applies to Hong Kong Chinese diagnosed with ACS. Further studies to explore effective interventions to address these psychosocial issues are recommended.

  3. Establishing a store baseline during interim storage of waste packages and a review of potential technologies for base-lining

    Energy Technology Data Exchange (ETDEWEB)

    McTeer, Jennifer; Morris, Jenny; Wickham, Stephen [Galson Sciences Ltd. Oakham, Rutland (United Kingdom); Bolton, Gary [National Nuclear Laboratory Risley, Warrington (United Kingdom); McKinney, James; Morris, Darrell [Nuclear Decommissioning Authority Moor Row, Cumbria (United Kingdom); Angus, Mike [National Nuclear Laboratory Risley, Warrington (United Kingdom); Cann, Gavin; Binks, Tracey [National Nuclear Laboratory Sellafield (United Kingdom)

    2013-07-01

    Interim storage is an essential component of the waste management lifecycle, providing a safe, secure environment for waste packages awaiting final disposal. In order to be able to monitor and detect change or degradation of the waste packages, storage building or equipment, it is necessary to know the original condition of these components (the 'waste storage system'). This paper presents an approach to establishing the baseline for a waste-storage system, and provides guidance on the selection and implementation of potential base-lining technologies. The approach is made up of two sections; assessment of base-lining needs and definition of base-lining approach. During the assessment of base-lining needs a review of available monitoring data and store/package records should be undertaken (if the store is operational). Evolutionary processes (affecting safety functions), and their corresponding indicators, that can be measured to provide a baseline for the waste-storage system should then be identified in order for the most suitable indicators to be selected for base-lining. In defining the approach, identification of opportunities to collect data and constraints is undertaken before selecting the techniques for base-lining and developing a base-lining plan. Base-lining data may be used to establish that the state of the packages is consistent with the waste acceptance criteria for the storage facility and to support the interpretation of monitoring and inspection data collected during store operations. Opportunities and constraints are identified for different store and package types. Technologies that could potentially be used to measure baseline indicators are also reviewed. (authors)

  4. Predicting seed yield in perennial ryegrass using repeated canopy reflectance measurements and PLSR

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Boelt, Birte

    2009-01-01

    with first year seed crops using three sowing rates and three spring nitrogen (N) application rates. PLSR models were developed for each year and showed correlation coefficients of 0.71, 0.76, and 0.92, respectively. Regression coefficients showed in these experiments that the optimum time for canopy...... reflectance measurements was from approximately 600 cumulative growing degree-days (CGDD) to approximately 900 CGDD. This is the period just before and at heading of the seed crop. Furthermore, regression coefficients showed that information about N and water is important. The results support the development......Repeated canopy reflectance measurements together with partial least-squares regression (PLSR) were used to predict seed yield in perennial ryegrass (Lolium perenne L.). The measurements were performed during the spring and summer growing seasons of 2001 to 2003 in three field experiments...

  5. Performance Analysis of Measurement Inaccuracies of IMU/GPS on Airborne Repeat-pass Interferometric SAR in the Presence of Squint

    Directory of Open Access Journals (Sweden)

    Deng Yuan

    2014-08-01

    Full Text Available In the MOtion COmpensation (MOCO approach to airborne repeat-pass interferometric Synthetic Aperture Radar (SAR based on motion measurement data, the measurement inaccuracies of Inertial Measurement Unit/Global Positioning System (IMU/GPS and the positioning errors of the target, which may contribute to the residual uncompensated motion errors, affect the imaging result and interferometric measurement. Considering the effects of the two types of error, this paper builds a mathematical model of residual motion errors in presence of squint, and analyzes the effects on the residual motion errors induced by the measurement inaccuracies of IMU/GPS and the positioning errors of the target. In particular, the effects of various measurement inaccuracies of IMU/GPS on interferometric SAR image quality, interferometric phase, and digital elevation model precision are disscussed. Moreover, the paper quantitatively researches the effects of residual motion errors on airborne repeat-pass interferometric SAR through theoretical and simulated analyses and provides theoretical bases for system design and signal processing.

  6. Short-term Changes of Apparent Optical Properties in a Shallow Water Environment: Observations from Repeated Airborne Hyperspectral Measurements

    Science.gov (United States)

    Zhang, M.; English, D. C.; Hu, C.; Carlson, P. R., Jr.; Muller-Karger, F. E.; Toro-Farmer, G.; Herwitz, S. R.

    2016-02-01

    An atmospheric correction algorithm has been developed for AISA imagery over optically shallow waters in Sugarloaf Key of the Florida Keys. The AISA data were collected repeatedly during several days in May 2012, October 2012, and May 2013. A non-zero near-infrared (NIR) remote sensing reflectance (Rrs) was accounted for through iterations, based on the relationship of field-measured Rrs between the NIR and red wavelengths. Validation showed mean ratios of 0.94 to 1.002 between AISA-derived and field-measured Rrs in the blue to red wavelengths, with uncertainties generally turbidity (light attenuation) and bottom contributions. Some of these changes are larger than two times of the Rrs uncertainties from the AISA retrievals, therefore representing statistically significant changes that can be well observed from airborne measurements. The case study suggests that repeated airborne measurements may be used to study short-term changes in shallow water environments, and such a capacity may be enhanced with future geostationary satellite missions specifically designed to observe coastal ecosystems.

  7. Application of a repeat-measure biomarker measurement error model to 2 validation studies: examination of the effect of within-person variation in biomarker measurements.

    Science.gov (United States)

    Preis, Sarah Rosner; Spiegelman, Donna; Zhao, Barbara Bojuan; Moshfegh, Alanna; Baer, David J; Willett, Walter C

    2011-03-15

    Repeat-biomarker measurement error models accounting for systematic correlated within-person error can be used to estimate the correlation coefficient (ρ) and deattenuation factor (λ), used in measurement error correction. These models account for correlated errors in the food frequency questionnaire (FFQ) and the 24-hour diet recall and random within-person variation in the biomarkers. Failure to account for within-person variation in biomarkers can exaggerate correlated errors between FFQs and 24-hour diet recalls. For 2 validation studies, ρ and λ were calculated for total energy and protein density. In the Automated Multiple-Pass Method Validation Study (n=471), doubly labeled water (DLW) and urinary nitrogen (UN) were measured twice in 52 adults approximately 16 months apart (2002-2003), yielding intraclass correlation coefficients of 0.43 for energy (DLW) and 0.54 for protein density (UN/DLW). The deattenuated correlation coefficient for protein density was 0.51 for correlation between the FFQ and the 24-hour diet recall and 0.49 for correlation between the FFQ and the biomarker. Use of repeat-biomarker measurement error models resulted in a ρ of 0.42. These models were similarly applied to the Observing Protein and Energy Nutrition Study (1999-2000). In conclusion, within-person variation in biomarkers can be substantial, and to adequately assess the impact of correlated subject-specific error, this variation should be assessed in validation studies of FFQs. © The Author 2011. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved.

  8. Repeatability and responsiveness of exercise tests in pulmonary arterial hypertension.

    Science.gov (United States)

    Mainguy, Vincent; Malenfant, Simon; Neyron, Anne-Sophie; Bonnet, Sébastien; Maltais, François; Saey, Didier; Provencher, Steeve

    2013-08-01

    Exercise tolerance in pulmonary arterial hypertension (PAH) is most commonly assessed by the 6-min walk test (6MWT). Whether endurance exercise tests are more responsive than the 6MWT remains unknown. 20 stable PAH patients (mean±sd age 53±15 years and mean pulmonary arterial pressure 44±16 mmHg) already on PAH monotherapy completed the 6MWT, the endurance shuttle walk test (ESWT) and the cycle endurance test (CET) before and after the addition of sildenafil citrate 20 mg three times daily or placebo for 28 days in a randomised double-blind crossover setting. Pre- or post-placebo tests were used to assess repeatability of each exercise test, whereas pre- or post-sildenafil citrate tests were used to assess their responsiveness. Sildenafil citrate led to placebo-corrected changes in exercise capacity of 18±25 m (p = 0.02), 58±235 s (p = 0.58) and 29±77 s (p = 0.09) for the 6MWT, the ESWT and the CET, respectively. The 6MWT was associated with a lower coefficient of variation between repeated measures (3% versus 18% versus 13%), resulting in a higher standardised response mean compared with endurance tests (0.72, 0.25 and 0.38 for the 6MWT, the ESWT and the CET, respectively). The 6MWT had the best ability to capture changes in exercise capacity when sildenafil citrate was combined with patients' baseline monotherapy, supporting its use as an outcome measure in PAH.

  9. Baseline measures for net-proton distributions in high energy heavy-ion collisions

    International Nuclear Information System (INIS)

    Netrakanti, P.K.; Mishra, D.K.; Mohanty, A.K.; Mohanty, B.

    2014-01-01

    The STAR experiment at the Relativistic Heavy-Ion Collider facility has reported results for the cumulants and their ratios from the net-proton distributions upto the fourth order cumulants at various collision energies. These measurements were carried to look for the signatures of the possible critical point (CP) in the phase diagram for a system undertaking strong interactions. The results show an intriguing dependence of the cumulant ratios C 3 /C 2 and C 4 /C 2 as a function of beam energy. The beam energy dependence appears to be non-monotonic in nature. However the experiment also reports that the energy dependence is observed to be consistent with expectation from an approach based on the independent production of proton and anti-protons in the collisions. In this paper we emphasize the need to have a proper baseline for appropriate interpretation of the cumulant measurements and argue that the comparison to independent production approach needs to be done with extreme caution

  10. Corticosterone stress response shows long-term repeatability and links to personality in free-living Nazca boobies.

    Science.gov (United States)

    Grace, Jacquelyn K; Anderson, David J

    2014-11-01

    The concept of "coping styles", or consistently different responses to stressors, is of broad interest in behavioral ecology and biomedicine. Two critical predictions of this concept are individual consistency of neurophysiological and behavioral responses (relative to population variability) and a negative relationship between aggression/proactivity and hypothalamic-pituitary-adrenal axis reactivity. Recent studies failed to provide strong support for these predictions, especially outside of strictly controlled conditions, and long-term measures to test the first prediction are rare. Here, we demonstrate individual repeatability across 2-3years of maximum circulating corticosterone concentration [CORT] and area under the [CORT] response curve (AUCI) during a standard capture-restraint test in wild, free-living adult Nazca boobies (Sula granti). We also show that the stress response predicts the personality traits aggression and anxiety in these birds (measured in the wild); however, the strength of these results was weak. Maximum [CORT] and AUCI showed higher repeatability between years than baseline [CORT]. After controlling breeding status, sex, mass, date sampled, and their interactions, baseline [CORT] was most closely related to personality traits, followed by AUCI, and then maximum [CORT]. The direction of these relationships depended on whether the testing context was social or non-social. [CORT] parameters had little to no relationship with cross-context plasticity in personality traits. Our results generally affirm two critical predictions of coping styles, but match the emerging trend that these relationships are weak in the wild, and may depend on testing context. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. The Repeated Administration of Resveratrol Has Measurable Effects on Circulating T-Cell Subsets in Humans

    Directory of Open Access Journals (Sweden)

    J. Luis Espinoza

    2017-01-01

    Full Text Available Preclinical studies have shown that resveratrol exerts immunomodulatory effects with potential clinical value in the amelioration of autoimmune disorders and cancer prevention; however, little is known about the in vivo effects of this naturally occurring polyphenol on human immune cells. We assessed the effects of repeated doses of resveratrol (1000 mg/day for 28 days on circulating immune cells in healthy Japanese individuals. Resveratrol was safe and well tolerated and was associated with significant increases in the numbers of circulating γδ T cells and regulatory T cells and resulted in small, yet significant, decreases in the plasma levels of the proinflammatory cytokines TNF-α and MCP-1 and a significant increase in the plasma antioxidant activity compared with the corresponding antioxidant baseline activity and with that in four control individuals. In in vitro studies, resveratrol significantly improved the growth of γδ T cells and regulatory T cells. These findings demonstrate that resveratrol has some clear biological effects on human circulating immune cells. Further studies are necessary to interpret the long-term immunological changes associated with resveratrol treatment.

  12. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Science.gov (United States)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-02-01

    The Gd5Ge2Si2 alloy and the off-stoichiometric Ni50Mn35In15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd5Ge2Si2 and Ni50Mn35In15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  13. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    International Nuclear Information System (INIS)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-01-01

    The Gd 5 Ge 2 Si 2 alloy and the off-stoichiometric Ni 50 Mn 35 In 15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd 5 Ge 2 Si 2 and Ni 50 Mn 35 In 15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis

  14. Repeatability and reproducibility of Population Viability Analysis (PVA and the implications for threatened species management

    Directory of Open Access Journals (Sweden)

    Clare Morrison

    2016-08-01

    Full Text Available Conservation triage focuses on prioritizing species, populations or habitats based on urgency, biodiversity benefits, recovery potential as well as cost. Population Viability Analysis (PVA is frequently used in population focused conservation prioritizations. The critical nature of many of these management decisions requires that PVA models are repeatable and reproducible to reliably rank species and/or populations quantitatively. This paper assessed the repeatability and reproducibility of a subset of previously published PVA models. We attempted to rerun baseline models from 90 publicly available PVA studies published between 2000-2012 using the two most common PVA modelling software programs, VORTEX and RAMAS-GIS. Forty percent (n = 36 failed, 50% (45 were both repeatable and reproducible, and 10% (9 had missing baseline models. Repeatability was not linked to taxa, IUCN category, PVA program version used, year published or the quality of publication outlet, suggesting that the problem is systemic within the discipline. Complete and systematic presentation of PVA parameters and results are needed to ensure that the scientific input into conservation planning is both robust and reliable, thereby increasing the chances of making decisions that are both beneficial and defensible. The implications for conservation triage may be far reaching if population viability models cannot be reproduced with confidence, thus undermining their intended value.

  15. Hepatitis C treatment response kinetics and impact of baseline predictors

    DEFF Research Database (Denmark)

    Lindh, M; Arnholm, B; Eilard, A

    2011-01-01

    Summary. The optimal duration of treatment for hepatitis C virus (HCV) infections is highly variable but critical for achieving cure (sustained virological response, SVR). We prospectively investigated the impact of age, fibrosis, baseline viraemia and genotype on the early viral kinetics...... above 400 000 IU/mL were strongly associated with slower second phase declines of HCV RNA. Genotype 2/3 infections responded more rapidly than genotype 1, reaching week 4 negativity (RVR) in 59%vs 22%. We conclude that baseline response predictors such as age, fibrosis and viral load were well reflected...... by the early viral kinetics as assessed by repeated HCV RNA quantifications. The kinetic patterns and the high relapse rate in genotype 2/3 patients without RVR suggest that this group might benefit from treatment durations longer than 24 weeks....

  16. Immune responses of eastern fence lizards (Sceloporus undulatus) to repeated acute elevation of corticosterone.

    Science.gov (United States)

    McCormick, Gail L; Langkilde, Tracy

    2014-08-01

    Prolonged elevations of glucocorticoids due to long-duration (chronic) stress can suppress immune function. It is unclear, however, how natural stressors that result in repeated short-duration (acute) stress, such as frequent agonistic social encounters or predator attacks, fit into our current understanding of the immune consequences of stress. Since these types of stressors may activate the immune system due to increased risk of injury, immune suppression may be reduced at sites where individuals are repeatedly exposed to potentially damaging stressors. We tested whether repeated acute elevation of corticosterone (CORT, a glucocorticoid) suppresses immune function in eastern fence lizards (Sceloporus undulatus), and whether this effect varies between lizards from high-stress (high baseline CORT, invaded by predatory fire ants) and low-stress (low baseline CORT, uninvaded) sites. Lizards treated daily with exogenous CORT showed higher hemagglutination of novel proteins by their plasma (a test of constitutive humoral immunity) than control lizards, a pattern that was consistent across sites. There was no significant effect of CORT treatment on bacterial killing ability of plasma. These results suggest that repeated elevations of CORT, which are common in nature, produce immune effects more typical of those expected at the acute end of the acute-chronic spectrum and provide no evidence of modulated consequences of elevated CORT in animals from high-stress sites. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Use of the Counseling Center Assessment of Psychological Symptoms 62 (CCAPS-62) as a Repeated Measure

    Science.gov (United States)

    Ghosh, Arpita; Rieder Bennett, Sara; Martin, Juanita K.

    2018-01-01

    The purpose of this initial, exploratory study was to examine the utility of the Counseling Center Assessment of Psychological Symptoms-62 (CCAPS-62) as a repeated measure tool at one university counseling center. This study investigated whether clients engaged in individual counseling changed in symptomology while in treatment and when (e.g.,…

  18. Examining the Perceived Value of Integration of Earned Value Management with Risk Management-Based Performance Measurement Baseline

    Science.gov (United States)

    Shah, Akhtar H.

    2014-01-01

    Many projects fail despite the use of evidence-based project management practices such as Performance Measurement Baseline (PMB), Earned Value Management (EVM) and Risk Management (RM). Although previous researchers have found that integrated project management techniques could be more valuable than the same techniques used by themselves, these…

  19. Baseline for the cumulants of net-proton distributions at STAR

    International Nuclear Information System (INIS)

    Luo, Xiaofeng; Mohanty, Bedangadas; Xu, Nu

    2014-01-01

    We present a systematic comparison between the recently measured cumulants of the net-proton distributions by STAR for 0–5% central Au + Au collisions at √(s NN )=7.7–200 GeV and two kinds of possible baseline measure, the Poisson and Binomial baselines. These baseline measures are assuming that the proton and anti-proton distributions independently follow Poisson statistics or Binomial statistics. The higher order cumulant net-proton data are observed to deviate from all the baseline measures studied at 19.6 and 27 GeV. We also compare the net-proton with net-baryon fluctuations in UrQMD and AMPT model, and convert the net-proton fluctuations to net-baryon fluctuations in AMPT model by using a set of formula

  20. Parsimonious Structural Equation Models for Repeated Measures Data, with Application to the Study of Consumer Preferences

    Science.gov (United States)

    Elrod, Terry; Haubl, Gerald; Tipps, Steven W.

    2012-01-01

    Recent research reflects a growing awareness of the value of using structural equation models to analyze repeated measures data. However, such data, particularly in the presence of covariates, often lead to models that either fit the data poorly, are exceedingly general and hard to interpret, or are specified in a manner that is highly data…

  1. The effect of tracking network configuration on GPS baseline estimates for the CASA Uno experiment

    Science.gov (United States)

    Wolf, S. Kornreich; Dixon, T. H.; Freymueller, J. T.

    1990-01-01

    The effect of the tracking network on long (greater than 100 km) GPS baseline estimates was estimated using various subsets of the global tracking network initiated by the first Central and South America (CASA Uno) experiment. It was found that best results could be obtained with a global tacking network consisting of three U.S. stations, two sites in the southwestern Pacific, and two sites in Europe. In comparison with smaller subsets, this global network improved the baseline repeatability, the resolution of carrier phase cycle ambiguities, and formal errors of the orbit estimates.

  2. Effect of repeated forearm muscle cooling on the adaptation of skeletal muscle metabolism in humans

    Science.gov (United States)

    Wakabayashi, Hitoshi; Nishimura, Takayuki; Wijayanto, Titis; Watanuki, Shigeki; Tochihara, Yutaka

    2017-07-01

    This study aimed to investigate the effect of repeated cooling of forearm muscle on adaptation in skeletal muscle metabolism. It is hypothesized that repeated decreases of muscle temperature would increase the oxygen consumption in hypothermic skeletal muscle. Sixteen healthy males participated in this study. Their right forearm muscles were locally cooled to 25 °C by cooling pads attached to the skin. This local cooling was repeated eight times on separate days for eight participants (experimental group), whereas eight controls received no cold exposure. To evaluate adaptation in skeletal muscle metabolism, a local cooling test was conducted before and after the repeated cooling period. Change in oxy-hemoglobin content in the flexor digitorum at rest and during a 25-s isometric handgrip (10% maximal voluntary construction) was measured using near-infrared spectroscopy at every 2 °C reduction in forearm muscle temperature. The arterial blood flow was occluded for 15 s by upper arm cuff inflation at rest and during the isometric handgrip. The oxygen consumption in the flexor digitorum muscle was evaluated by a slope of the oxy-hemoglobin change during the arterial occlusion. In the experimental group, resting oxygen consumption in skeletal muscle did not show any difference between pre- and post-intervention, whereas muscle oxygen consumption during the isometric handgrip was significantly higher in post-intervention than in pre-test from thermoneutral baseline to 31 °C muscle temperature ( P cooling might facilitate oxidative metabolism in the skeletal muscle. In summary, skeletal muscle metabolism during submaximal isometric handgrip was facilitated after repeated local muscle cooling.

  3. The role of TRAIL in fatigue induced by repeated stress from radiotherapy.

    Science.gov (United States)

    Feng, Li Rebekah; Suy, Simeng; Collins, Sean P; Saligan, Leorey N

    2017-08-01

    Fatigue is one of the most common and debilitating side effects of cancer and cancer treatment, and yet its etiology remains elusive. The goal of this study is to understand the role of chronic inflammation in fatigue following repeated stress from radiotherapy. Fatigue and non-fatigue categories were assessed using ≥ 3-point change in Functional Assessment of Cancer Therapy-Fatigue questionnaire (FACT-F) administered to participants at baseline/before radiotherapy and one year post-radiotherapy. Whole genome microarray and cytokine multiplex panel were used to examine fatigue-related transcriptome and serum cytokine changes, respectively. The study included 86 subjects (discovery phase n = 40, validation phase n = 46). The sample in the discovery phase included men with prostate cancer scheduled to receive external-beam radiotherapy. A panel of 48 cytokines were measured and the significantly changed cytokine found in the discovery phase was validated using sera from a separate cohort of men two years after completing radiotherapy for prostate cancer at a different institution. Effects of the significantly changed cytokine on cell viability was quantified using the MTT assay. During the discovery phase, tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) and TRAIL decoy receptor, TNFRSF10C (TRAIL-R3), were significantly upregulated in fatigued (≥3-point decrease from baseline to 1yr-post radiotherapy) subjects (n = 15). In the validation phase, TRAIL correlated with fatigue scores 2yrs post-radiotherapy. TRAIL caused selective cytotoxicity in neuronal cells, but not in microglial and muscle cells, in vitro. Late-onset inflammation directed by TRAIL may play a role in fatigue pathogenesis post-repeated stress from irradiation. Published by Elsevier Ltd.

  4. Enhancement of creative expression and entoptic phenomena as after-effects of repeated ayahuasca ceremonies.

    Science.gov (United States)

    Frecska, Ede; Móré, Csaba E; Vargha, András; Luna, Luis E

    2012-01-01

    Studying the effect of psychedelic substances on expression of creativity is a challenging problem. Our primary objective was to study the psychometric measures of creativity after a series of ayahuasca ceremonies at a time when the acute effects have subsided. The secondary objective was to investigate how entoptic phenomena emerge during expression of creativity. Forty individuals who were self-motivated participants of ayahuasca rituals in Brazil completed the visual components of the Torrance Tests of Creative Thinking before and the second day after the end of a two-week long ceremony series. Twenty-one comparison subjects who did not participate in recent psychedelic use also took the Torrance tests twice, two weeks apart. Repeated ingestion of ayahuasca in the ritual setting significantly increased the number of highly original solutions and phosphenic responses. However, participants in the ayahuasca ceremonies exhibited more phosphenic solutions already at the baseline, probably due to the fact that they had more psychedelic experiences within six months prior to the study than the comparison subjects did. This naturalistic study supports the notion that some measures of visual creativity may increase after ritual use of ayahuasca, when the acute psychoactive effects are receded. It also demonstrates an increased entoptic activity after repeated ayahuasca ingestion.

  5. Intrafractional baseline drift during free breathing breast cancer radiation therapy.

    Science.gov (United States)

    Jensen, Christer Andre; Acosta Roa, Ana María; Lund, Jo-Åsmund; Frengen, Jomar

    2017-06-01

    Intrafraction motion in breast cancer radiation therapy (BCRT) has not yet been thoroughly described in the literature. It has been observed that baseline drift occurs as part of the intrafraction motion. This study aims to measure baseline drift and its incidence in free-breathing BCRT patients using an in-house developed laser system for tracking the position of the sternum. Baseline drift was monitored in 20 right-sided breast cancer patients receiving free breathing 3D-conformal RT by using an in-house developed laser system which measures one-dimensional distance in the AP direction. A total of 357 patient respiratory traces from treatment sessions were logged and analysed. Baseline drift was compared to patient positioning error measured from in-field portal imaging. The mean overall baseline drift at end of treatment sessions was -1.3 mm for the patient population. Relatively small baseline drift was observed during the first fraction; however it was clearly detected already at the second fraction. Over 90% of the baseline drift occurs during the first 3 min of each treatment session. The baseline drift rate for the population was -0.5 ± 0.2 mm/min in the posterior direction the first minute after localization. Only 4% of the treatment sessions had a 5 mm or larger baseline drift at 5 min, all towards the posterior direction. Mean baseline drift in the posterior direction in free breathing BCRT was observed in 18 of 20 patients over all treatment sessions. This study shows that there is a substantial baseline drift in free breathing BCRT patients. No clear baseline drift was observed during the first treatment session; however, baseline drift was markedly present at the rest of the sessions. Intrafraction motion due to baseline drift should be accounted for in margin calculations.

  6. ±25ppm repeatable measurement of trapezoidal pulses with 5MHz bandwidth

    CERN Document Server

    AUTHOR|(SzGeCERN)712364; Arpaia, Pasquale; Cerqueira Bastos, Miguel; Martino, Michele

    2015-01-01

    High-quality measurements of pulses are nowadays widely used in fields such as radars, pulsed lasers, electromagnetic pulse generators, and particle accelerators. Whilst literature is mainly focused on fast systems for nanosecond regime with relaxed metrological requirements, in this paper, the high-performance measurement of slower pulses in microsecond regime is faced. In particular, the experimental proof demonstration for a 15 MS/s,_25 ppm repeatable acquisition system to characterize the flat-top of 3 ms rise-time trapezoidal pulses is given. The system exploits a 5MHz bandwidth circuit for analogue signal processing based on the concept of flat-top removal. The requirements, as well as the conceptual and physical designs are illustrated. Simulation results aimed at assessing the circuit performance are also presented. Finally, an experimental case study on the characterization of a pulsed power supply for the klystrons modulators of the Compact Linear Collider (CLIC) under study at CERN is reported. In ...

  7. A repeating fast radio burst.

    Science.gov (United States)

    Spitler, L G; Scholz, P; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-03-10

    Fast radio bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measure (that is, the integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of these bursts has led to the suggestion that they originate in cataclysmic events. Here we report observations of ten additional bursts from the direction of the fast radio burst FRB 121102. These bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB 121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB 121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and which vary on timescales of minutes or less. Although there may be multiple physical origins for the population of fast radio bursts, these repeat bursts with high dispersion measure and variable spectra specifically seen from the direction of FRB 121102 support an origin in a young, highly magnetized, extragalactic neutron star.

  8. Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts

    Directory of Open Access Journals (Sweden)

    Resat Duman

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate anterior segment measurements obtained using CSO Sirius Topographer® (CSO, Firenze, Italy and Nidek Axial Length (AL-Scan® (Nidek CO., Gamagori, Japan. Methods: A total of 43 eyes of 43 patients were included in this prospective study. The central corneal thickness (CCT, anterior chamber depth (ACD, white-to-white distance (WTW, flat keratometry (K1, steep keratometry (K2, and mean keratometry (K values were randomly measured three times with each device by the same examiner. The intraclass correlation coefficient of repeatability was analyzed. The compatibility of both devices was evaluated using the 95% limits of the agreement proposed by Bland and Altman. Results: Examiner achieved high repeatability for all parameters on each device except the WTW measured by Sirius. All measurements except WTW and K1 taken with the Sirius were higher than that taken with the Nidek AL-Scan®. The difference in CCT, ACD, and WTW values was statistically significant. Conclusion: High repeatability of the measurements was achieved on both devices. Although Km, K1, and K2 measurements of the Sirius and the AL-Scan® showed good agreement, WTW, CCT, and ACD measurements significantly differed between two devices. Thus, anterior segment measurements except for Km, K1, and K2 cannot be used interchangeably between Sirius and Nidek AL-Scan® devices.

  9. Tectonic, Climatic and Anthropogenic Vertical Land Movements in Western Europe by Repeated Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M. J.; de Viron, O.; Lecocq, T.; Hinzen, K. G.; Quinif, Y.; Williams, S. D.; Camelbeeck, T.

    2010-12-01

    In continental plate interiors, tectonic deformations are small and the associated ground surface movements remain close to or below the accuracy of current geodetic techniques, and at the limit of the noise level. An absolute gravimeter is an appropriate tool to quantify slow vertical movements, as this instrument, based on length and time standards, is drift free and does not depend on any terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformations in the area. After 7-13 years (depending on the station), we find evidence that the movements are no larger than a few millimeter per year and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. This demonstrates the importance of precisely modeling the GIA effects in order to investigate intraplate tectonic deformations at the sub-millimeter level. This study also shows that AG measurements, repeated once or twice a year, can resolve vertical velocities at the 1.0 mm/yr level after 10 years, even in difficult conditions, provided that the gravimeter is carefully maintained.

  10. Correlation of normal-range FMR1 repeat length or genotypes and reproductive parameters.

    Science.gov (United States)

    Maslow, Bat-Sheva L; Davis, Stephanie; Engmann, Lawrence; Nulsen, John C; Benadiva, Claudio A

    2016-09-01

    This study aims to ascertain whether the length of normal-ranged CGG repeats on the FMR1 gene correlates with abnormal reproductive parameters. We performed a retrospective, cross-sectional study of all FMR1 carrier screening performed as part of routine care at a large university-based fertility center from January 2011 to March 2014. Correlations were performed between normal-range FMR1 length and baseline serum anti-Müllerian hormone (AMH), cycle day 3 follicle stimulating hormone (FSH), ovarian volumes (OV), antral follicle counts (AFC), and incidence of diminished ovarian reserve (DOR), while controlling for the effect of age. Six hundred three FMR1 screening results were collected. One subject was found to be a pre-mutation carrier and was excluded from the study. Baseline serum AMH, cycle day 3 FSH, OV, and AFC data were collected for the 602 subjects with normal-ranged CGG repeats. No significant difference in median age was noted amongst any of the FMR1 repeat genotypes. No significant correlation or association was found between any allele length or genotype, with any of the reproductive parameters or with incidence of DOR at any age (p > 0.05). However, subjects who were less than 35 years old with low/low genotype were significantly more likely to have below average AMH levels compared to those with normal/normal genotype (RR 3.82; 95 % CI 1.38-10.56). This large study did not demonstrate any substantial association between normal-range FMR1 repeat lengths and reproductive parameters.

  11. Baseline glucose level is an individual trait that is negatively associated with lifespan and increases due to adverse environmental conditions during development and adulthood

    NARCIS (Netherlands)

    Montoya, Bibiana; Briga, Michael; Jimeno, Blanca; Moonen, Sander; Verhulst, Simon

    High baseline glucose levels are associated with pathologies and shorter lifespan in humans, but little is known about causes and consequences of individual variation in glucose levels in other species. We tested to what extent baseline blood glucose level is a repeatable trait in adult zebra

  12. Repeatability of two-dimensional chemical shift imaging multivoxel proton magnetic resonance spectroscopy for measuring human cerebral choline-containing compounds.

    Science.gov (United States)

    Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip

    2018-03-22

    To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.

  13. 40 CFR 74.20 - Data for baseline and alternative baseline.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Data for baseline and alternative baseline. 74.20 Section 74.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... baseline and alternative baseline. (a) Acceptable data. (1) The designated representative of a combustion...

  14. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study.

    Science.gov (United States)

    Aten, Jan Jaap; Oudega, Mardien; van Exel, Eric; Stek, Max L; van Waarde, Jeroen A

    2015-06-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment characteristics, clinical outcome, and cognitive functioning after ECT. Thirty-nine unipolar depressed patients dosed using repeated DTM and 40 matched patients treated with ABM were compared. Montgomery-Åsberg Depression Rating Scale (MADRS) and Mini-Mental State Examination (MMSE) were assessed at baseline and at the end of the index course, as well as the total number of ECT sessions. Both groups were similar regarding age, sex, psychotic features, mean baseline MADRS, and median baseline MMSE. At the end of the index course, the two methods showed equal outcome (mean end MADRS, 11.6 ± 8.3 in DTM and 9.5 ± 7.6 in ABM (P = 0.26); median end MMSE, 28 (25-29) and 28 (25-29.8), respectively (P = 0.81). However, the median number of all ECT sessions differed 16 (11-22) in DTM versus 12 (10-14.8) in ABM; P = 0.02]. Using regression analysis, dosing method and age were independently associated with the total number of ECT sessions, with less sessions needed in ABM (P = 0.02) and in older patients (P = 0.001). In this comparative cohort study, ABM and DTM showed equal outcome for depression and cognition. However, the median ECT course duration in repeated DTM appeared longer. Additionally, higher age was associated with shorter ECT courses regardless of the dosing method. Further prospective studies are needed to confirm these findings.

  15. Acute caffeine effect on repeatedly measured P300

    OpenAIRE

    Pan, Jingbo; Takeshita, Tatsuya; Morimoto, Kanehisa

    2000-01-01

    The acute effect of a single-dose of caffeine on the P300 event-related brain potential (ERP) was assessed in a study using a repeatedly presented auditory oddball button-press task. A dose (5mg/kg body-weight) of either caffeine or placebo lactose, dissolved in a cup of decaffeinated coffee, was administered double-blindly to coffee drinkers who had abstained from coffee for 24hrs, with the presentation order of the sessions counterbalanced and separated by 2–4 weeks. The caffeine-treatment ...

  16. Diabetic Foot Prevention: Repeatability of the Loran Platform Plantar Pressure and Load Distribution Measurements in Nondiabetic Subjects during Bipedal Standing—A Pilot Study

    Directory of Open Access Journals (Sweden)

    Martha Zequera

    2011-01-01

    Full Text Available This study was designed to assess the repeatability of the Loran Platform and evaluate the variability of plantar pressure and postural balance, during barefoot standing in nondiabetic subjects, for future diabetic foot clinical evaluation. Measurements were taken for eight nondiabetic subjects (4 females, 4 males, aged 47±7.2 years who had no musculoskeletal symptoms. Five variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. For most measurements, no significant effect over time was found with Student's t-test (P<.000125. The ANOVA test of statistical significance confirmed that measurement differences between subjects showed higher variations than measurements taken from the same subject (P<.001. The measurements taken by the Loran Platform system were found to be repeatable.

  17. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography

    Science.gov (United States)

    Johnson, Mark I.; Francis, Peter

    2018-01-01

    Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885

  18. Perspectives on repeated low-level blast and the measurement of neurotrauma in humans as an occupational exposure risk

    Science.gov (United States)

    Carr, W.; Dell, K. C.; Yanagi, M. A.; Hassan, D. M.; LoPresti, M. L.

    2017-11-01

    A pressing question in military medical research is the nature and degree of effects on the human brain from occupational repeated exposure to low-level explosive blast, but reliable and effective means to objectively measure such effects remain elusive. In survey results, headache, difficulty sleeping, irritability, cognitive impairment, and a variety of other symptoms consistent with post-concussive syndrome have been reported by those exposed to blast and there was positive correlation between degree of blast exposure and degree of symptomology, but an important goal is to obtain more objective evidence of an effect than self-report alone. This review reflects recent efforts to measure and evaluate such hypothesized effects and current recommendations for ongoing study. Optimal measures are likely those with sensitivity and specificity to systemic effects in mild neurotrauma, that have minimal to no volitional component, and that can be sampled relatively quickly with minimal intrusion in prospective, observational field studies during routine training with explosives. An understanding of an association between parameters of exposure to repeated low-level blast and negative neurologic effects would support the evaluation of clinical implications and development of protective equipment and surveillance protocols where warranted. At present, low-level blast exposure surveillance measurements do not exist as a systematic record for any professional community.

  19. Reproducibility and repeatability of a new computerized software for sagittal spinopelvic and scoliosis curvature radiologic measurements: Keops(®).

    Science.gov (United States)

    Maillot, C; Ferrero, E; Fort, D; Heyberger, C; Le Huec, J-C

    2015-07-01

    The purpose of this study was to evaluate the inter- and intra-observer variability of the computerized radiologic measurements using Keops(®) and to determine the bias between the software and the standard paper measurement. Four individuals measured all frontal and sagittal variables on the 30 X-rays randomly selected on two occasions (test and retest conditions). The Bland-Altman plot was used to determine the degree of agreement between the measurement on paper X-ray and the measurement using Keops(®) for all reviewers and for the two measures; the intraclass correlation coefficient (ICC) was calculated for each pair of analyses to assess interobserver reproducibility among the four reviewers for the same patient using either paper X-ray or Keops(®) measurement and finally, concordance correlation coefficient (rc) was calculated to assess intraobserver repeatability among the same reviewer for one patient between the two measure using the same method (paper or Keops(®)). The mean difference calculated between the two methods was minimal at -0, 4° ± 3.41° [-7.1; 6.4] for frontal measurement and 0.1° ± 3.52° [-6.7; 6.8] for sagittal measurement. Keops(®) has a better interobserver reproducibility than paper measurement for determination of the sagittal pelvic parameter (ICC = 0.9960 vs. 0.9931; p = 0.0001). It has a better intraobserver repeatability than paper for determination of Cobbs angle (rc = 0.9872 vs. 0.9808; p rc = 0.9981 vs. 0.9953; p plane and that the use of this software can be recommended for clinical application. Diagnostic, level III.

  20. The effect of milk on recovery from repeat-sprint cycling in female team-sport athletes.

    Science.gov (United States)

    Rankin, Paula; Lawlor, Michael J; Hills, Frank A; Bell, Phillip G; Stevenson, Emma J; Cockburn, Emma

    2018-02-01

    The consumption of milk following eccentric exercise attenuates the effects of muscle damage in team-sport athletes. However, participation in team sport involves both concentric-eccentric loading and metabolic stress. Therefore, the aim of this study was to investigate the effects of postexercise milk consumption on recovery from a cycling protocol designed to simulate the metabolic demands of team sport. Ten female team-sport athletes participated in a randomised crossover investigation. Upon completion of the protocol participants consumed 500 mL of milk (MILK) or 500 mL of an energy-matched carbohydrate (CHO) drink. Muscle function (peak torque, rate of force development, countermovement jump, 20-m sprint), muscle soreness and tiredness, serum creatine kinase, high-sensitivity C-reactive protein, and measures of oxidative stress (protein carbonyls and reduced glutathione/oxidized glutathione (GSH/GSSG) ratio) were determined at pre-exercise and 24 h, 48 h, and 72 h postexercise. MILK had a possible beneficial effect in attenuating losses in peak torque (180°/s) from baseline to 24 h (3.2% ± 7.8% vs. -6.2% ± 7.5%, MILK vs. CHO) and a possible beneficial effect in minimising soreness (baseline-48 h; baseline-72 h) and tiredness (baseline-24 h; baseline-72 h). There was no change in oxidative stress following the exercise protocol, though a likely benefit of milk was observed for GSH/GSSG ratio at baseline-24 h (0.369 ×/÷ 1.89, 1.103 ×/÷ 3.96, MILK vs. CHO). MILK had an unclear effect on all other variables. Consumption of 500 mL of milk after repeat sprint cycling had little to no benefit in minimising losses in peak torque or minimising increases in soreness and tiredness and had no effect on serum markers of muscle damage and inflammation.

  1. Baseline glucose level is an individual trait that is negatively associated with lifespan and increases due to adverse environmental conditions during development and adulthood.

    Science.gov (United States)

    Montoya, Bibiana; Briga, Michael; Jimeno, Blanca; Moonen, Sander; Verhulst, Simon

    2018-05-01

    High baseline glucose levels are associated with pathologies and shorter lifespan in humans, but little is known about causes and consequences of individual variation in glucose levels in other species. We tested to what extent baseline blood glucose level is a repeatable trait in adult zebra finches, and whether glucose levels were associated with age, manipulated environmental conditions during development (rearing brood size) and adulthood (foraging cost), and lifespan. We found that: (1) repeatability of glucose levels was 30%, both within and between years. (2) Having been reared in a large brood and living with higher foraging costs as adult were independently associated with higher glucose levels. Furthermore, the finding that baseline glucose was low when ambient temperature was high, and foraging costs were low, indicates that glucose is regulated at a lower level when energy turnover is low. (3) Survival probability decreased with increasing baseline glucose. We conclude that baseline glucose is an individual trait negatively associated with survival, and increases due to adverse environmental conditions during development (rearing brood size) and adulthood (foraging cost). Blood glucose may be, therefore, part of the physiological processes linking environmental conditions to lifespan.

  2. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    DEFF Research Database (Denmark)

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty

    2011-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original...

  3. SCAT3 changes from baseline and associations with X2 Patch measured head acceleration in amateur Australian football players.

    Science.gov (United States)

    Willmott, Catherine; McIntosh, Andrew S; Howard, Teresa; Mitra, Biswadev; Dimech-Betancourt, Bleydy; Donovan, Jarrod; Rosenfeld, Jeffrey V

    2018-05-01

    To investigate changes from baseline on SCAT3 as a result of football game exposure, and association with X2 Patch measured head acceleration events in amateur Australian footballers. Prospective cohort. Peak linear acceleration (PLA) of the head (>10 g) was measured by wearable head acceleration sensor X2 Biosystems X-Patch in male (n=34) and female (n=19) Australian footballers. SCAT3 was administered at baseline (B) and post-game (PG). 1394 head acceleration events (HEA) >10 g were measured. Mean and median HEA PLA were recorded as 15.2 g (SD=9.2, range=10.0-115.8) and 12.4 g (IQR=11.0-15.6) respectively. No significant difference in median HEA PLA (g) was detected across gender (p=0.55), however, more HEAs were recorded in males (p=0.03). A greater number (p=0.004) and severity (p0.05 for all), was identified for either gender. Increase in symptom severity post game was not associated with X2 measured HEA. Males sustained more HEA, however HEA PLA magnitude did not differ across gender. Further work on the validation of head acceleration sensors is required and their role in sports concussion research and medical management. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  4. A long baseline global stereo matching based upon short baseline estimation

    Science.gov (United States)

    Li, Jing; Zhao, Hong; Li, Zigang; Gu, Feifei; Zhao, Zixin; Ma, Yueyang; Fang, Meiqi

    2018-05-01

    In global stereo vision, balancing the matching efficiency and computing accuracy seems to be impossible because they contradict each other. In the case of a long baseline, this contradiction becomes more prominent. In order to solve this difficult problem, this paper proposes a novel idea to improve both the efficiency and accuracy in global stereo matching for a long baseline. In this way, the reference images located between the long baseline image pairs are firstly chosen to form the new image pairs with short baselines. The relationship between the disparities of pixels in the image pairs with different baselines is revealed by considering the quantized error so that the disparity search range under the long baseline can be reduced by guidance of the short baseline to gain matching efficiency. Then, the novel idea is integrated into the graph cuts (GCs) to form a multi-step GC algorithm based on the short baseline estimation, by which the disparity map under the long baseline can be calculated iteratively on the basis of the previous matching. Furthermore, the image information from the pixels that are non-occluded under the short baseline but are occluded for the long baseline can be employed to improve the matching accuracy. Although the time complexity of the proposed method depends on the locations of the chosen reference images, it is usually much lower for a long baseline stereo matching than when using the traditional GC algorithm. Finally, the validity of the proposed method is examined by experiments based on benchmark datasets. The results show that the proposed method is superior to the traditional GC method in terms of efficiency and accuracy, and thus it is suitable for long baseline stereo matching.

  5. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography.

    Directory of Open Access Journals (Sweden)

    Hannah V Wilson

    Full Text Available The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG has not been published.To investigate the; (1 reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm, (2 effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude and contraction time (Tc, (3 the effect of changing inter-electrode distance on Dm and Tc.Within subject, repeated measures.10 participants for each objective.Dm and Tc of the rectus femoris, measured using TMG.The coefficient of variance (CV and the intra-class correlation (ICC of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively.Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles.

  6. Effect of Sucrose Analgesia, for Repeated Painful Procedures, on Short-term Neurobehavioral Outcome of Preterm Neonates: A Randomized Controlled Trial.

    Science.gov (United States)

    Banga, Shreshtha; Datta, Vikram; Rehan, Harmeet Singh; Bhakhri, Bhanu Kiran

    2016-04-01

    Safety of oral sucrose, commonly used procedural analgesic in neonates, is questioned. To evaluate the effect of sucrose analgesia, for repeated painful procedures, on short-term neurobehavioral outcome of preterm neonates. Stable preterm neonates were randomized to receive either sucrose or distilled water orally, for every potentially painful procedure during the first 7 days after enrollment. Neurodevelopmental status at 40 weeks postconceptional age (PCA) measured using the domains of Neurobehavioral Assessment of Preterm Infants scale. A total of 93 newborns were analyzed. The baseline characteristics of the groups were comparable. No statistically significant difference was observed in the assessment at 40 weeks PCA, among the groups. Use of sucrose analgesia, for repeated painful procedures on newborns, does not lead to any significant difference in the short-term neurobehavioral outcome. © The Author [2015]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Should Studies of Diabetes Treatment Stratification Correct for Baseline HbA1c?

    Science.gov (United States)

    Jones, Angus G.; Lonergan, Mike; Henley, William E.; Pearson, Ewan R.; Hattersley, Andrew T.; Shields, Beverley M.

    2016-01-01

    Aims Baseline HbA1c is a major predictor of response to glucose lowering therapy and therefore a potential confounder in studies aiming to identify other predictors. However, baseline adjustment may introduce error if the association between baseline HbA1c and response is substantially due to measurement error and regression to the mean. We aimed to determine whether studies of predictors of response should adjust for baseline HbA1c. Methods We assessed the relationship between baseline HbA1c and glycaemic response in 257 participants treated with GLP-1R agonists and assessed whether it reflected measurement error and regression to the mean using duplicate ‘pre-baseline’ HbA1c measurements not included in the response variable. In this cohort and an additional 2659 participants treated with sulfonylureas we assessed the relationship between covariates associated with baseline HbA1c and treatment response with and without baseline adjustment, and with a bias correction using pre-baseline HbA1c to adjust for the effects of error in baseline HbA1c. Results Baseline HbA1c was a major predictor of response (R2 = 0.19,β = -0.44,pHbA1c were associated with response, however these associations were weak or absent after adjustment for baseline HbA1c. Bias correction did not substantially alter associations. Conclusions Adjustment for the baseline HbA1c measurement is a simple and effective way to reduce bias in studies of predictors of response to glucose lowering therapy. PMID:27050911

  8. Back-calculating baseline creatinine overestimates prevalence of acute kidney injury with poor sensitivity.

    Science.gov (United States)

    Kork, F; Balzer, F; Krannich, A; Bernardi, M H; Eltzschig, H K; Jankowski, J; Spies, C

    2017-03-01

    Acute kidney injury (AKI) is diagnosed by a 50% increase in creatinine. For patients without a baseline creatinine measurement, guidelines suggest estimating baseline creatinine by back-calculation. The aim of this study was to evaluate different glomerular filtration rate (GFR) equations and different GFR assumptions for back-calculating baseline creatinine as well as the effect on the diagnosis of AKI. The Modification of Diet in Renal Disease, the Chronic Kidney Disease Epidemiology (CKD-EPI) and the Mayo quadratic (MQ) equation were evaluated to estimate baseline creatinine, each under the assumption of either a fixed GFR of 75 mL min -1  1.73 m -2 or an age-adjusted GFR. Estimated baseline creatinine, diagnoses and severity stages of AKI based on estimated baseline creatinine were compared to measured baseline creatinine and corresponding diagnoses and severity stages of AKI. The data of 34 690 surgical patients were analysed. Estimating baseline creatinine overestimated baseline creatinine. Diagnosing AKI based on estimated baseline creatinine had only substantial agreement with AKI diagnoses based on measured baseline creatinine [Cohen's κ ranging from 0.66 (95% CI 0.65-0.68) to 0.77 (95% CI 0.76-0.79)] and overestimated AKI prevalence with fair sensitivity [ranging from 74.3% (95% CI 72.3-76.2) to 90.1% (95% CI 88.6-92.1)]. Staging AKI severity based on estimated baseline creatinine had moderate agreement with AKI severity based on measured baseline creatinine [Cohen's κ ranging from 0.43 (95% CI 0.42-0.44) to 0.53 (95% CI 0.51-0.55)]. Diagnosing AKI and staging AKI severity on the basis of estimated baseline creatinine in surgical patients is not feasible. Patients at risk for post-operative AKI should have a pre-operative creatinine measurement to adequately assess post-operative AKI. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  9. Dehydration and performance on clinical concussion measures in collegiate wrestlers.

    Science.gov (United States)

    Weber, Amanda Friedline; Mihalik, Jason P; Register-Mihalik, Johna K; Mays, Sally; Prentice, William E; Guskiewicz, Kevin M

    2013-01-01

    The effects of dehydration induced by wrestling-related weight-cutting tactics on clinical concussion outcomes, such as neurocognitive function, balance performance, and symptoms, have not been adequately studied. To evaluate the effects of dehydration on the outcome of clinical concussion measures in National Collegiate Athletic Association Division I collegiate wrestlers. Repeated-measures design. Clinical research laboratory. Thirty-two Division I healthy collegiate male wrestlers (age = 20.0 ± 1.4 years; height = 175.0 ± 7.5 cm; baseline mass = 79.2 ± 12.6 kg). Participants completed preseason concussion baseline testing in early September. Weight and urine samples were also collected at this time. All participants reported to prewrestling practice and postwrestling practice for the same test battery and protocol in mid-October. They had begun practicing weight-cutting tactics a day before prepractice and postpractice testing. Differences between these measures permitted us to evaluate how dehydration and weight-cutting tactics affected concussion measures. Sport Concussion Assessment Tool 2 (SCAT2), Balance Error Scoring System, Graded Symptom Checklist, and Simple Reaction Time scores. The Simple Reaction Time was measured using the Automated Neuropsychological Assessment Metrics. The SCAT2 measurements were lower at prepractice (P = .002) and postpractice (P < .001) when compared with baseline. The BESS error scores were higher at postpractice when compared with baseline (P = .015). The GSC severity scores were higher at prepractice (P = .011) and postpractice (P < .001) than at baseline and at postpractice when than at prepractice (P = .003). The number of Graded Symptom Checklist symptoms reported was also higher at prepractice (P = .036) and postpractice (P < .001) when compared with baseline, and at postpractice when compared with prepractice (P = .003). Our results suggest that it is important for wrestlers to be evaluated in a euhydrated state to

  10. Test-retest repeatability of the pupil light response to blue and red light stimuli in normal human eyes using a novel pupillometer

    Directory of Open Access Journals (Sweden)

    Kristina eHerbst

    2011-02-01

    Full Text Available In this study, we evaluated the repeatability of pupil responses to colored light stimuli in healthy subjects using a prototype chromatic pupillometer. One eye of 10 healthy subjects was tested twice in the same day using monochromatic light exposure at 2 selected wavelengths (660 nm and 470 nm, intensity 300 cd/m2 presented continuously for 20 seconds. Pupil responses were recorded in real time before, during and after light exposure. Maximal contraction amplitude and sustained contraction amplitude were calculated. In addition, we quantified the summed pupil response during continuous light stimulation as the total area between a reference line representing baseline pupil size and the line representing actual pupil size over 20 seconds (area under the curve. There was no significant difference in the repeated measure compared to the first test for any of the pupil response parameters. In conclusion, we have developed a novel prototype of color pupillometer which demonstrates good repeatability in evoking and recording the pupillary response to a bright blue and red light stimulus.

  11. Item response theory analysis of the mechanics baseline test

    Science.gov (United States)

    Cardamone, Caroline N.; Abbott, Jonathan E.; Rayyan, Saif; Seaton, Daniel T.; Pawl, Andrew; Pritchard, David E.

    2012-02-01

    Item response theory is useful in both the development and evaluation of assessments and in computing standardized measures of student performance. In item response theory, individual parameters (difficulty, discrimination) for each item or question are fit by item response models. These parameters provide a means for evaluating a test and offer a better measure of student skill than a raw test score, because each skill calculation considers not only the number of questions answered correctly, but the individual properties of all questions answered. Here, we present the results from an analysis of the Mechanics Baseline Test given at MIT during 2005-2010. Using the item parameters, we identify questions on the Mechanics Baseline Test that are not effective in discriminating between MIT students of different abilities. We show that a limited subset of the highest quality questions on the Mechanics Baseline Test returns accurate measures of student skill. We compare student skills as determined by item response theory to the more traditional measurement of the raw score and show that a comparable measure of learning gain can be computed.

  12. Probing neutrino oscillations jointly in long and very long baseline experiments

    International Nuclear Information System (INIS)

    Wang, Y.F.; Whisnant, K.; Young Binglin; Xiong Zhaohua; Yang Jinmin

    2002-01-01

    We examine the prospects of making a joint analysis of neutrino oscillations at two baselines with neutrino superbeams. Assuming narrow band superbeams and a 100 kiloton water Cherenkov calorimeter, we calculate the event rates and sensitivities to the matter effect, the signs of the neutrino mass differences, the CP phase, and the mixing angle θ 13 . Taking into account all possible experimental errors under general consideration, we explore the optimum cases of a narrow band beam to measure the matter effect and the CP violation effect at all baselines up to 3000 km. We then focus on two specific baselines, a long baseline of 300 km and a very long baseline of 2100 km, and analyze their joint capabilities. We find that the joint analysis can offer extra leverage to resolve some of the ambiguities that are associated with the measurement at a single baseline

  13. Repeatable aversion across threat types is linked with life-history traits but is dependent on how aversion is measured.

    Science.gov (United States)

    Davidson, Gabrielle L; Reichert, Michael S; Crane, Jodie M S; O'Shea, William; Quinn, John L

    2018-02-01

    Personality research suggests that individual differences in risk aversion may be explained by links with life-history variation. However, few empirical studies examine whether repeatable differences in risk avoidance behaviour covary with life-history traits among individuals in natural populations, or how these links vary depending on the context and the way risk aversion is measured. We measured two different risk avoidance behaviours (latency to enter the nest and inspection time) in wild great tits ( Parus major ) in two different contexts-response to a novel object and to a predator cue placed at the nest-box during incubation---and related these behaviours to female reproductive success and condition. Females responded equally strongly to both stimuli, and although both behaviours were repeatable, they did not correlate. Latency to enter was negatively related to body condition and the number of offspring fledged. By contrast, inspection time was directly explained by whether incubating females had been flushed from the nest before the trial began. Thus, our inferences on the relationship between risk aversion and fitness depend on how risk aversion was measured. Our results highlight the limitations of drawing conclusions about the relevance of single measures of a personality trait such as risk aversion.

  14. Dynamic Pain Phenotypes are Associated with Spinal Cord Stimulation-Induced Reduction in Pain: A Repeated Measures Observational Pilot Study.

    Science.gov (United States)

    Campbell, Claudia M; Buenaver, Luis F; Raja, Srinivasa N; Kiley, Kasey B; Swedberg, Lauren J; Wacnik, Paul W; Cohen, Steven P; Erdek, Michael A; Williams, Kayode A; Christo, Paul J

    2015-07-01

    Spinal cord stimulation (SCS) has become a widely used treatment option for a variety of pain conditions. Substantial variability exists in the degree of benefit obtained from SCS and patient selection is a topic of expanding interest and importance. However, few studies have examined the potential benefits of dynamic quantitative sensory testing (QST) to develop objective measures of SCS outcomes or as a predictive tool to help patient selection. Psychological characteristics have been shown to play an important role in shaping individual differences in the pain experience and may aid in predicting responses to SCS. Static laboratory pain-induction measures have also been examined in their capacity for predicting SCS outcomes. The current study evaluated clinical, psychological and laboratory pain measures at baseline, during trial SCS lead placement, as well as 1 month and 3 months following permanent SCS implantation in chronic pain patients who received SCS treatment. Several QST measures were conducted, with specific focus on examination of dynamic models (central sensitization and conditioned pain modulation [CPM]) and their association with pain outcomes 3 months post SCS implantation. Results suggest few changes in QST over time. However, central sensitization and CPM at baseline were significantly associated with clinical pain at 3 months following SCS implantation, controlling for psycho/behavioral factors and pain at baseline. Specifically, enhanced central sensitization and reduced CPM were associated with less self-reported pain 3 months following SCS implantation. These findings suggest a potentially important role for dynamic pain assessment in individuals undergoing SCS, and hint at potential mechanisms through which SCS may impart its benefit. Wiley Periodicals, Inc.

  15. Direct and Repeated Clinical Measurements of pO2 for Enhancing Cancer Therapy and Other Applications.

    Science.gov (United States)

    Swartz, Harold M; Williams, Benjamin B; Hou, Huagang; Khan, Nadeem; Jarvis, Lesley A; Chen, Eunice Y; Schaner, Philip E; Ali, Arif; Gallez, Bernard; Kuppusamy, Periannan; Flood, Ann B

    2016-01-01

    The first systematic multi-center study of the clinical use of EPR oximetry has begun, with funding as a PPG from the NCI. Using particulate oxygen sensitive EPR, materials in three complementary forms (India Ink, "OxyChips", and implantable resonators) the clinical value of the technique will be evaluated. The aims include using repeated measurement of tumor pO2 to monitor the effects of treatments on tumor pO2, to use the measurements to select suitable subjects for the type of treatment including the use of hyperoxic techniques, and to provide data that will enable existing clinical techniques which provide data relevant to tumor pO2 but which cannot directly measure it to be enhanced by determining circumstances where they can give dependable information about tumor pO2.

  16. Repeated low-dose exposures to sarin, soman, or VX affect acoustic startle in guinea pigs.

    Science.gov (United States)

    Smith, C D; Lee, R B; Moran, A V; Sipos, M L

    2016-01-01

    Chemical warfare nerve agents (CWNAs) are known to cause behavioral abnormalities in cases of human exposures and in animal models. The behavioral consequences of single exposures to CWNAs that cause observable toxic signs are particularly well characterized in animals; however, less is known regarding repeated smaller exposures that may or may not cause observable toxic signs. In the current study, guinea pigs were exposed to fractions (0.1, 0.2, or 0.4) of a medial lethal dose (LD50) of sarin, soman, or VX for two weeks. On each exposure day, and for a post-exposure period, acoustic startle response (ASR) was measured in each animal. Although relatively few studies use guinea pigs to measure behavior, this species is ideal for CWNA-related experiments because their levels of carboxylesterases closely mimic those of humans, unlike rats or mice. Results showed that the 0.4 LD50 doses of soman and VX transiently increased peak startle amplitude by the second week of injections, with amplitude returning to baseline by the second week post-exposure. Sarin also increased peak startle amplitude independent of week. Latencies to peak startle and PPI were affected by agent exposure but not consistently among the three agents. Most of the changes in startle responses returned to baseline following the cessation of exposures. These data suggest that doses of CWNAs not known to produce observable toxic signs in guinea pigs can affect behavior in the ASR paradigm. Further, these deficits are transient and usually return to baseline shortly after the end of a two-week exposure period. Published by Elsevier Inc.

  17. The repeatability of interleukin-6, tumor necrosis factor-α, and C-reactive protein in COPD patients over one year

    Directory of Open Access Journals (Sweden)

    Umme Kolsum

    2009-04-01

    Full Text Available Umme Kolsum, Kay Roy, Cerys Starkey, Zoë Borrill, Nick Truman, Jørgen Vestbo, Dave SinghNorth West Lung Research Centre, University of Manchester, South Manchester University Hospitals Trust, Wythenshawe, Manchester, UKBackground: Many of the systemic manifestations of chronic obstructive pulmonary disease (COPD are mediated through increased systemic levels of inflammatory proteins. We assessed the long term repeatability of Interleukin-6 (IL-6, tumor necrosis factor-α (TNF-α, and C-reactive protein (CRP over one year and examined the relationships between these systemic markers in COPD.Methods: Fifty-eight stable COPD patients completed a baseline and one-year visit. Serum IL-6, plasma CRP, and plasma TNF-α were measured. Repeatability was expressed by intraclass correlation coefficient (Ri and the Bland–Altman method. Pearson correlations were used to determine the relationships between the systemic markers at both visits.Results: There was moderate repeatability with a very high degree of statistical significance (p ≤ 0.001 between the two visits for all the systemic biomarkers (IL-6, CRP, and TNF-α. CRP was significantly associated with IL-6 at both visits (r = 0.55, p = 0.0001, r = 0.51, p = 0.0002, respectively. There were no other significant associations between the systemic markers at either of the visits.Conclusions: Systemic inflammatory biomarkers IL-6, CRP, and TNF-α were moderately repeatable over a twelve month period in COPD patients. We have also shown that a robust and repeatable association between IL-6 and CRP exists.Keywords: interleukin-6, tumor necrosis factor-α, C-reactive protein, repeatability, COPD   

  18. Repeatability study of replicate crash tests: A signal analysis approach.

    Science.gov (United States)

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2017-10-03

    To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test

  19. A Modified Jonckheere Test Statistic for Ordered Alternatives in Repeated Measures Design

    Directory of Open Access Journals (Sweden)

    Hatice Tül Kübra AKDUR

    2016-09-01

    Full Text Available In this article, a new test based on Jonckheere test [1] for  randomized blocks which have dependent observations within block is presented. A weighted sum for each block statistic rather than the unweighted sum proposed by Jonckheereis included. For Jonckheere type statistics, the main assumption is independency of observations within block. In the case of repeated measures design, the assumption of independence is violated. The weighted Jonckheere type statistic for the situation of dependence for different variance-covariance structure and the situation based on ordered alternative hypothesis structure of each block on the design is used. Also, the proposed statistic is compared to the existing test based on Jonckheere in terms of type I error rates by performing Monte Carlo simulation. For the strong correlations, circular bootstrap version of the proposed Jonckheere test provides lower rates of type I error.

  20. Reproducibility and Reliability of Repeated Quantitative Fluorescence Angiography

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Knudsen, Kristine Bach Korsholm; Ambrus, Rikard

    2017-01-01

    INTRODUCTION: When using fluorescence angiography (FA) in perioperative perfusion assessment, repeated measures with re-injections of fluorescent dye (ICG) may be required. However, repeated injections may cause saturation of dye in the tissue, exceeding the limit of fluorescence intensity...... that the camera can detect. As the emission of fluorescence is dependent of the excitatory light intensity, reduction of this may solve the problem. The aim of the present study was to investigate the reproducibility and reliability of repeated quantitative FA during a reduction of excitatory light....

  1. Trunk muscle activation during golf swing: Baseline and threshold.

    Science.gov (United States)

    Silva, Luís; Marta, Sérgio; Vaz, João; Fernandes, Orlando; Castro, Maria António; Pezarat-Correia, Pedro

    2013-10-01

    There is a lack of studies regarding EMG temporal analysis during dynamic and complex motor tasks, such as golf swing. The aim of this study is to analyze the EMG onset during the golf swing, by comparing two different threshold methods. Method A threshold was determined using the baseline activity recorded between two maximum voluntary contraction (MVC). Method B threshold was calculated using the mean EMG activity for 1000ms before the 500ms prior to the start of the Backswing. Two different clubs were also studied. Three-way repeated measures ANOVA was used to compare methods, muscles and clubs. Two-way mixed Intraclass Correlation Coefficient (ICC) with absolute agreement was used to determine the methods reliability. Club type usage showed no influence in onset detection. Rectus abdominis (RA) showed the higher agreement between methods. Erector spinae (ES), on the other hand, showed a very low agreement, that might be related to postural activity before the swing. External oblique (EO) is the first being activated, at 1295ms prior impact. There is a similar activation time between right and left muscles sides, although the right EO showed better agreement between methods than left side. Therefore, the algorithms usage is task- and muscle-dependent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Heart failure re-admission: measuring the ever shortening gap between repeat heart failure hospitalizations.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Bakal

    Full Text Available Many quality-of-care and risk prediction metrics rely on time to first rehospitalization even though heart failure (HF patients may undergo several repeat hospitalizations. The aim of this study is to compare repeat hospitalization models. Using a population-based cohort of 40,667 patients, we examined both HF and all cause re-hospitalizations using up to five years of follow-up. Two models were examined: the gap-time model which estimates the adjusted time between hospitalizations and a multistate model which considered patients to be in one of four states; community-dwelling, in hospital for HF, in hospital for any reason, or dead. The transition probabilities and times were then modeled using patient characteristics and number of repeat hospitalizations. We found that during the five years of follow-up roughly half of the patients returned for a subsequent hospitalization for each repeat hospitalization. Additionally, we noted that the unadjusted time between hospitalizations was reduced ∼40% between each successive hospitalization. After adjustment each additional hospitalization was associated with a 28 day (95% CI: 22-35 reduction in time spent out of hospital. A similar pattern was seen when considering the four state model. A large proportion of patients had multiple repeat hospitalizations. Extending the gap between hospitalizations should be an important goal of treatment evaluation.

  3. Kinematic repeatability of a multi-segment foot model for dance.

    Science.gov (United States)

    Carter, Sarah L; Sato, Nahoko; Hopper, Luke S

    2018-03-01

    The purpose of this study was to determine the intra and inter-assessor repeatability of a modified Rizzoli Foot Model for analysing the foot kinematics of ballet dancers. Six university-level ballet dancers performed the movements; parallel stance, turnout plié, turnout stance, turnout rise and flex-point-flex. The three-dimensional (3D) position of individual reflective markers and marker triads was used to model the movement of the dancers' tibia, entire foot, hindfoot, midfoot, forefoot and hallux. Intra and inter-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability for the first metatarsophalangeal joint in the sagittal plane. Intra-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability during flex-point-flex across all inter-segmental angles except for the tibia-hindfoot and hindfoot-midfoot frontal planes. Inter-assessor repeatability ranged from poor to excellent (0.5 > ICC ≥ 0.75) for the 3D segment rotations. The most repeatable measure was the tibia-foot dorsiflexion/plantar flexion articulation whereas the least repeatable measure was the hindfoot-midfoot adduction/abduction articulation. The variation found in the inter-assessor results is likely due to inconsistencies in marker placement. This 3D dance specific multi-segment foot model provides insight into which kinematic measures can be reliably used to ascertain in vivo technical errors and/or biomechanical abnormalities in a dancer's foot motion.

  4. EFFICIENCY OF REPEATED AND UNSCHEDULED TRAINING AS THE MEASURES TO PREVENT ACCIDENTS AT SUPPLY DEPOTS AND WAREHOUSES

    Directory of Open Access Journals (Sweden)

    Bocharova Irina Nikolaevna

    2013-05-01

    Full Text Available This paper presents the results of the analysis of the state of occupational safety at supply depots and warehouses. It is revealed that most accidents involve the employees who have less than one year’s service. Experience has proven that the preventive activities to avoid occupational traumatism are efficient when a complex of workplace safety measures is implemented. The experts consider the repeated and unscheduled training to be very important events. This is supported by the fact that among the employees of the commercial establishments who underwent repeated and unscheduled training, the number of individuals who suffered an accident is small. The efficient functioning of the occupational safety training system is infeasible without ensuring the motivation for assimilating the knowledge and forming the complete foundation for safe labor. In order to reduce the number of accidents, one should proceed from the principle of responding to accidents to the system for professional risk management.

  5. MALDI-TOF Baseline Drift Removal Using Stochastic Bernstein Approximation

    Directory of Open Access Journals (Sweden)

    Howard Daniel

    2006-01-01

    Full Text Available Stochastic Bernstein (SB approximation can tackle the problem of baseline drift correction of instrumentation data. This is demonstrated for spectral data: matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF data. Two SB schemes for removing the baseline drift are presented: iterative and direct. Following an explanation of the origin of the MALDI-TOF baseline drift that sheds light on the inherent difficulty of its removal by chemical means, SB baseline drift removal is illustrated for both proteomics and genomics MALDI-TOF data sets. SB is an elegant signal processing method to obtain a numerically straightforward baseline shift removal method as it includes a free parameter that can be optimized for different baseline drift removal applications. Therefore, research that determines putative biomarkers from the spectral data might benefit from a sensitivity analysis to the underlying spectral measurement that is made possible by varying the SB free parameter. This can be manually tuned (for constant or tuned with evolutionary computation (for .

  6. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Phypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  7. Measuring Baseline Agriculture-Related Sustainable Development Goals Index for Southern Africa

    Directory of Open Access Journals (Sweden)

    Charles Nhemachena

    2018-03-01

    Full Text Available Sustainable development has become the main focus of the global development agenda as presented in the 2015 Sustainable Development Goals (SDGs. However, for countries to assess progress, they need to have reliable baseline indicators. Therefore, the objective of this paper is to develop a composite baseline index of the agriculture-related SDGs in Southern Africa to guide progress reporting. The paper identified eight of the SDG indicators related to the agriculture sector. The paper relies on data for indicators from five SDGs (SDGs 1, 2, 6, 7 and 15. Applying the arithmetic mean method of aggregation, an agriculture-related SDG composite index for Southern Africa between zero (0 = poor performance and 100 (best possible performance was computed for thirteen countries that had data on all identified indicators. The results show that the best performing countries (Botswana, Angola, Namibia, Zambia and South Africa in the assessment recorded high scores in SDGs 1, 2 and 7. The three countries (Democratic Republic of Congo, Zimbabwe and Madagascar that performed poorly on both SDG 1 and 2 also had the least scores on the overall agriculture-related SDG composite index. The water stress indicator for SDG 6 recorded the worst performance among most countries in the region. Possible approaches to improve the contribution of agriculture to SDGs may include investing more resources in priority areas for each agriculture-related SDG depending on baseline country conditions. The implementation, monitoring and evaluation of regional and continental commitments in the agriculture sector and the SDGs are critical for achievement of the targets at the national and local levels. While the methods employed are well-grounded in literature, data unavailability for some of the SDGs in some countries presented a limitation to the study, and future efforts should focus on collecting data for the other SDGs in order to permit a wider application.

  8. Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes

    OpenAIRE

    Ruiz-Belda, Clara; Piñero, David P.; Ruiz Fortes, Pedro; Soto-Negro, Roberto; Moya, Myriam; Pérez Cambrodí, Rafael J.; Artola, Alberto

    2016-01-01

    Purpose: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode. Methods: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the C...

  9. Case study: videogame distraction reduces behavioral distress in a preschool-aged child undergoing repeated burn dressing changes: a single-subject design.

    Science.gov (United States)

    Sil, Soumitri; Dahlquist, Lynnda M; Burns, Andrew J

    2013-04-01

    This single-subject design study evaluated the feasibility and efficacy of passive and interactive videogame distraction on behavioral distress for a preschool-aged child receiving repeated burn dressing changes. A 4-year-old girl underwent 3 baseline and 10 videogame distraction sessions (5 passive and 5 interactive) using a restricted alternating treatments design. Observed behavioral distress was coded, and parents and nurses rated the child's distress and cooperative behavior. Relative to baseline, behavioral distress decreased and cooperative behavior increased immediately after the onset of videogame distraction. Single Case Randomization Tests revealed significantly lower behavioral distress and greater cooperation during interactive videogame distraction relative to passive videogame distraction. Interactive videogame distraction appears to be a feasible and effective pain management strategy for a preschool-aged child undergoing repeated painful medical procedures.

  10. Carbon tetrachloride ERA soil-gas baseline monitoring

    International Nuclear Information System (INIS)

    Fancher, J.D.

    1994-01-01

    From December 1991 through December 1993, Westinghouse Hanford Company performed routine baseline monitoring of selected wells ad soil-gas points twice weekly in the 200 West Area of the Hanford Site. This work supported the carbon Tetrachloride Expedited Response Action (ERA) and provided a solid baseline of volatile organic compound (VOC) concentrations in wells and in the subsurface at the ERA site. As site remediation continues, comparisons to this baseline can be one means of measuring the success of carbon tetrachloride vapor extraction. This report contains observations of the patterns and trends associated with data obtained during soil-gas monitoring at the 200 West Area: Monitoring performed since late 1991 includes monitoring soil-gas probes ad wellheads for volatile organic compounds (VOCs). This report reflects monitoring data collected from December 1991 through December 1993

  11. Quantum key distribution with two-segment quantum repeaters

    Energy Technology Data Exchange (ETDEWEB)

    Kampermann, Hermann; Abruzzo, Silvestre; Bruss, Dagmar [Theoretische Physik III, Heinrich-Heine-Universitaet Duesseldorf (Germany)

    2014-07-01

    Quantum repeaters represent one possible way to achieve long-distance quantum key distribution. One way of improving the repeater rate and decreasing the memory coherence time is the usage of multiplexing. Motivated by the experimental fact that long-range connections are practically demanding, we extend the analysis of the quantum repeater multiplexing protocol to the case of short-range connections. We derive formulas for the repeater rate and we show that short-range connections lead to most of the benefits of a full-range multiplexing protocol. A less demanding QKD-protocol without quantum memories was recently introduced by Lo et al. We generalize this measurement-device-independent quantum key Distribution protocol to the scenario where the repeater Station contains also heralded quantum memories. We assume either single-photon sources or weak coherent pulse sources plus decay states. We show that it is possible to significantly outperform the original proposal, even in presence of decoherence of the quantum memory. We give formulas in terms of device imperfections i.e., the quantum bit error rate and the repeater rate.

  12. Stability analysis of geomagnetic baseline data obtained at Cheongyang observatory in Korea

    Science.gov (United States)

    Amran, Shakirah M.; Kim, Wan-Seop; Cho, Heh Ree; Park, Po Gyu

    2017-07-01

    The stability of baselines produced by Cheongyang (CYG) observatory from the period of 2014 to 2016 is analysed. Step heights of higher than 5 nT were found in H and Z components in 2014 and 2015 due to magnetic noise in the absolute-measurement hut. In addition, a periodic modulation behaviour observed in the H and Z baseline curves was related to annual temperature variation of about 20 °C in the fluxgate magnetometer hut. Improvement in data quality was evidenced by a small dispersion between successive measurements from June 2015 to the end of 2016. Moreover, the baseline was also improved by correcting the discontinuity in the H and Z baselines.

  13. Stability analysis of geomagnetic baseline data obtained at Cheongyang observatory in Korea

    Directory of Open Access Journals (Sweden)

    S. M. Amran

    2017-07-01

    Full Text Available The stability of baselines produced by Cheongyang (CYG observatory from the period of 2014 to 2016 is analysed. Step heights of higher than 5 nT were found in H and Z components in 2014 and 2015 due to magnetic noise in the absolute-measurement hut. In addition, a periodic modulation behaviour observed in the H and Z baseline curves was related to annual temperature variation of about 20 °C in the fluxgate magnetometer hut. Improvement in data quality was evidenced by a small dispersion between successive measurements from June 2015 to the end of 2016. Moreover, the baseline was also improved by correcting the discontinuity in the H and Z baselines.

  14. Use of count-based image reconstruction to evaluate the variability and repeatability of measured standardised uptake values.

    Directory of Open Access Journals (Sweden)

    Tomohiro Kaneta

    Full Text Available Standardized uptake values (SUVs are the most widely used quantitative imaging biomarkers in PET. It is important to evaluate the variability and repeatability of measured SUVs. Phantom studies seem to be essential for this purpose; however, repetitive phantom scanning is not recommended due to the decay of radioactivity. In this study, we performed count-based image reconstruction to avoid the influence of decay using two different PET/CT scanners. By adjusting the ratio of 18F-fluorodeoxyglucose solution to tap water, a NEMA IEC body phantom was set for SUVs of 4.0 inside six hot spheres. The PET data were obtained using two scanners (Aquiduo and Celesteion; Toshiba Medical Systems, Tochigi, Japan. We set the start time for image reconstruction when the total radioactivity in the phantom was 2.53 kBq/cc, and employed the counts of the first 2-min acquisition as the standard. To maintain the number of counts for each image, we set the acquisition time for image reconstruction depending on the decay of radioactivity. We obtained 50 images, and calculated the SUVmax and SUVpeak of all six spheres in each image. The average values of the SUVmax were used to calculate the recovery coefficients to compare those measured by the two different scanners. Bland-Altman analyses of the SUVs measured by the two scanners were also performed. The measured SUVs using the two scanners exhibited a 10-30% difference, and the standard deviation (SD of the measured SUVs was between 0.1-0.2. The Celesteion always exhibited higher values than the Aquiduo. The smaller sphere exhibited a larger SD, and the SUVpeak had a smaller SD than the SUVmax. The Bland-Altman analyses showed poor agreement between the SUVs measured by the two scanners. The recovery coefficient curves obtained from the two scanners were considerably different. The Celesteion exhibited higher recovery coefficients than the Aquiduo, especially at approximately 20-mm-diameter. Additionally, the curves

  15. Variability in baseline laboratory measurements of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    Science.gov (United States)

    Ladwig, R; Vigo, A; Fedeli, L M G; Chambless, L E; Bensenor, I; Schmidt, M I; Vidigal, P G; Castilhos, C D; Duncan, B B

    2016-08-01

    Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008-2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31-0.65) and serum potassium (ICC=0.73; 95%CI=0.60-0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements.

  16. Automated genotyping of dinucleotide repeat markers

    Energy Technology Data Exchange (ETDEWEB)

    Perlin, M.W.; Hoffman, E.P. [Carnegie Mellon Univ., Pittsburgh, PA (United States)]|[Univ. of Pittsburgh, PA (United States)

    1994-09-01

    The dinucleotide repeats (i.e., microsatellites) such as CA-repeats are a highly polymorphic, highly abundant class of PCR-amplifiable markers that have greatly streamlined genetic mapping experimentation. It is expected that over 30,000 such markers (including tri- and tetranucleotide repeats) will be characterized for routine use in the next few years. Since only size determination, and not sequencing, is required to determine alleles, in principle, dinucleotide repeat genotyping is easily performed on electrophoretic gels, and can be automated using DNA sequencers. Unfortunately, PCR stuttering with these markers generates not one band for each allele, but a pattern of bands. Since closely spaced alleles must be disambiguated by human scoring, this poses a key obstacle to full automation. We have developed methods that overcome this obstacle. Our model is that the observed data is generated by arithmetic superposition (i.e., convolution) of multiple allele patterns. By quantitatively measuring the size of each component band, and exploiting the unique stutter pattern associated with each marker, closely spaced alleles can be deconvolved; this unambiguously reconstructs the {open_quotes}true{close_quotes} allele bands, with stutter artifact removed. We used this approach in a system for automated diagnosis of (X-linked) Duchenne muscular dystrophy; four multiplexed CA-repeats within the dystrophin gene were assayed on a DNA sequencer. Our method accurately detected small variations in gel migration that shifted the allele size estimate. In 167 nonmutated alleles, 89% (149/167) showed no size variation, 9% (15/167) showed 1 bp variation, and 2% (3/167) showed 2 bp variation. We are currently developing a library of dinucleotide repeat patterns; together with our deconvolution methods, this library will enable fully automated genotyping of dinucleotide repeats from sizing data.

  17. A COMPARISON OF PAIRS FIGURE SKATERS IN REPEATED JUMPS

    Directory of Open Access Journals (Sweden)

    William A. Sands

    2012-03-01

    Full Text Available Trends in pairs figure skating have shown that increasingly difficult jumps have become an essential aspect of high-level performance, especially in the latter part of a competitive program. We compared a repeated jump power index in a 60 s repeated jump test to determine the relationship of repeated jump test to competitive rank and to measure 2D hip, knee, and ankle angles and angular velocities at 0, 20, 40, and 60 s. Eighteen National Team Pairs Figure Skaters performed a 60 s repeated jump test on a large switch-mat with timing of flight and ground durations and digital video recording. Each 60-s period was divided into 6, 10-s intervals, with power indexes (W/kg calculated for each 10-s interval. Power index by 10-s interval repeated measures ANOVAs (RMANOVA showed that males exceeded females at all intervals, and the highest power index interval was during 10 to 20 s for both sexes. RMANOVAs of angles and angular velocities showed main effects for time only. Power index and jumping techniques among figure skaters showed rapid and steady declines over the test duration. Power index can predict approximately 50% of competitive rank variance, and sex differences in jumping technique were rare

  18. Elevating Baseline Activation Does Not Facilitate Reading of Unattended Words

    Science.gov (United States)

    Lien, Mei-Ching; Kouchi, Scott; Ruthruff, Eric; Lachter, Joel B.

    2009-01-01

    Previous studies have disagreed the extent to which people extract meaning from words presented outside the focus of spatial attention. The present study, examined a possible explanation for such discrepancies, inspired by attenuation theory: unattended words can be read more automatically when they have a high baseline level of activation (e.g., due to frequent repetition or due to being expected in a given context). We presented a brief prime word in lowercase, followed by a target word in uppercase. Participants indicated whether the target word belonged to a particular category (e.g., "sport"). When we drew attention to the prime word using a visual cue, the prime produced substantial priming effects on target responses (i.e., faster responses when the prime and target words were identical or from the same category than when they belonged to different categories). When prime words were not attended, however, they produced no priming effects. This finding replicated even when there were only 4 words, each repeated 160 times during the experiment. Even with a very high baseline level of activation, it appears that very little word processing is possible without spatial attention.

  19. Does repeat Hb measurement within 2 hours after a normal initial Hb in stable trauma patients add value to trauma evaluation?

    NARCIS (Netherlands)

    Sierink, Joanne C.; Joosse, Pieter; de Castro, Steve M. M.; Schep, Niels W. L.; Goslings, J. Carel

    2014-01-01

    In our level I trauma center, it is considered common practice to repeat blood haemoglobin measurements in patients within 2 h after admission. However, the rationale behind this procedure is elusive and can be considered labour-intensive, especially in patients in whom haemorrhaging is not to be

  20. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients...... with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS...... macular subfields. Repeatability was calculated according to methods described by Bland and Altman. RESULTS: 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm...

  1. GPS survey in long baseline neutrino-oscillation measurement

    CERN Document Server

    Noumi, H; Inagaki, T; Hasegawa, T; Katoh, Y; Kohama, M; Kurodai, M; Kusano, E; Maruyama, T; Minakawa, M; Nakamura, K; Nishikawa, K; Sakuda, M; Suzuki, Y; Takasaki, M; Tanaka, K H; Yamanoi, Y; 10.1109/TNS.2004.836042

    2004-01-01

    We made a series of surveys to obtain neutrino beam line direction toward SuperKamiokande (SK) at a distance of 250 km for the long- baseline neutrino oscillation experiment at KEK. We found that the beam line is directed to SK within 0.03 mr and 0.09 mr (in sigma) in the horizontal and vertical directions, respectively. During beam operation, we monitored the muon distribution from secondary pions produced at the target and collected by a magnetic horn system. We found that the horn system functions like a lens of a point-to- parallel optics with magnification of approximately -100 and the focal length of 2.3 m. Namely, a small displacement of the primary beam position at the target is magnified about a factor -100 at the muon centroid, while the centroid position is almost stable against a change of the incident angle of the primary beam. Therefore, the muon centroid can be a useful monitor of the neutrino beam direction. We could determine the muon centroid within 6 mm and 12 mm in horizontal and vertical ...

  2. Accuracy of repeated kidney size estimation by ultrasonography and urography in children

    International Nuclear Information System (INIS)

    Hederstroem, E.; Forsberg, L.

    1985-01-01

    The accuracy of repeated sonographic and urographic kidney length measurements in kidney size evaluation was investigated in 80 children 0 to 14 years of age, mean age 4.5 years. At sonography 250 kidney lengths were compared. A difference of 0 to 1.0 cm in repeated length measurement was considered to be good accuracy and 94 per cent of right and 96 per cent of left kidney length were found within this interval-a better result than for urography with 76 per cent of repeated right kidney and 79 per cent of kidney lengths within the same interval (94 lengths). Both methods display a variation of kidney lengths which may lead to under- and overestimation of kidney size and growth. The investigation thus indicates good accuracy for repeated sonographic kidney size assessment which should be repeated often enough to estabilish a growth chart displaying the trend rather than rely too much on single measurements. Sonography can be highly recommended as a convenient and harmless alternative to urography. (orig.)

  3. Precise baseline determination for the TanDEM-X mission

    Science.gov (United States)

    Koenig, Rolf; Moon, Yongjin; Neumayer, Hans; Wermuth, Martin; Montenbruck, Oliver; Jäggi, Adrian

    The TanDEM-X mission will strive for generating a global precise Digital Elevation Model (DEM) by way of bi-static SAR in a close formation of the TerraSAR-X satellite, already launched on June 15, 2007, and the TanDEM-X satellite to be launched in May 2010. Both satellites carry the Tracking, Occultation and Ranging (TOR) payload supplied by the GFZ German Research Centre for Geosciences. The TOR consists of a high-precision dual-frequency GPS receiver, called Integrated GPS Occultation Receiver (IGOR), and a Laser retro-reflector (LRR) for precise orbit determination (POD) and atmospheric sounding. The IGOR is of vital importance for the TanDEM-X mission objectives as the millimeter level determination of the baseline or distance between the two spacecrafts is needed to derive meter level accurate DEMs. Within the TanDEM-X ground segment GFZ is responsible for the operational provision of precise baselines. For this GFZ uses two software chains, first its Earth Parameter and Orbit System (EPOS) software and second the BERNESE software, for backup purposes and quality control. In a concerted effort also the German Aerospace Center (DLR) generates precise baselines independently with a dedicated Kalman filter approach realized in its FRNS software. By the example of GRACE the generation of baselines with millimeter accuracy from on-board GPS data can be validated directly by way of comparing them to the intersatellite K-band range measurements. The K-band ranges are accurate down to the micrometer-level and therefore may be considered as truth. Both TanDEM-X baseline providers are able to generate GRACE baselines with sub-millimeter accuracy. By merging the independent baselines by GFZ and DLR, the accuracy can even be increased. The K-band validation however covers solely the along-track component as the K-band data measure just the distance between the two GRACE satellites. In addition they inhibit an un-known bias which must be modelled in the comparison, so the

  4. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Na Lae; Chang, Hang Seok; Gweon, Hye Mi; Kim, Jeong Ah; Youk, Ji Hyun; Son, Eun Jun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoo, Mi Ri [Dept. of Radiology, Dongjak Kyunghee Hospital, Seoul (Korea, Republic of); Park, Ah Young [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Moon, Hee Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  5. Geochemical baseline studies of soil in Finland

    Science.gov (United States)

    Pihlaja, Jouni

    2017-04-01

    The soil element concentrations regionally vary a lot in Finland. Mostly this is caused by the different bedrock types, which are reflected in the soil qualities. Geological Survey of Finland (GTK) is carrying out geochemical baseline studies in Finland. In the previous phase, the research is focusing on urban areas and mine environments. The information can, for example, be used to determine the need for soil remediation, to assess environmental impacts or to measure the natural state of soil in industrial areas or mine districts. The field work is done by taking soil samples, typically at depth between 0-10 cm. Sampling sites are chosen to represent the most vulnerable areas when thinking of human impacts by possible toxic soil element contents: playgrounds, day-care centers, schools, parks and residential areas. In the mine districts the samples are taken from the areas locating outside the airborne dust effected areas. Element contents of the soil samples are then analyzed with ICP-AES and ICP-MS, Hg with CV-AAS. The results of the geochemical baseline studies are published in the Finnish national geochemical baseline database (TAPIR). The geochemical baseline map service is free for all users via internet browser. Through this map service it is possible to calculate regional soil baseline values using geochemical data stored in the map service database. Baseline data for 17 elements in total is provided in the map service and it can be viewed on the GTK's web pages (http://gtkdata.gtk.fi/Tapir/indexEN.html).

  6. Association of Transcatheter Aortic Valve Replacement With 30-Day Renal Function and 1-Year Outcomes Among Patients Presenting With Compromised Baseline Renal Function: Experience From the PARTNER 1 Trial and Registry.

    Science.gov (United States)

    Beohar, Nirat; Doshi, Darshan; Thourani, Vinod; Jensen, Hanna; Kodali, Susheel; Zhang, Feifan; Zhang, Yiran; Davidson, Charles; McCarthy, Patrick; Mack, Michael; Kapadia, Samir; Leon, Martin; Kirtane, Ajay

    2017-07-01

    The frequency of baseline renal impairment among high-risk and inoperable patients with severe aortic stenosis undergoing a transcatheter aortic valve replacement (TAVR) and the effect of TAVR on subsequent renal function are, to our knowledge, unknown. To determine the effect of TAVR among patients with baseline renal impairment. This substudy of patients with baseline renal impairment (estimated glomerular filtration rate [eGFR] ≤ 60 mL/min) and paired baseline and 30-day measures of renal function undergoing TAVR in the PARTNER 1 trial and continued access registries was conducted in 25 centers in the United States and Canada. Patients were categorized with improved eGFR (30-day follow-up eGFR≥10% higher than baseline pre-TAVR), worsened eGFR (≥10% lower), or no change in renal function (neither). Baseline characteristics, 30-day to 1-year all-cause mortality, and repeat hospitalization were compared. Multivariable models were constructed to identify predictors of 1-year mortality and of improvement/worsening in eGFR. Of the 821 participants, 401 (48.8%) were women and the mean (SD) age for participants with improved, unchanged, or worsening eGFR was 84.90 (6.91) years, 84.37 (7.13) years, and 85.39 (6.40) years, respectively. The eGFR was 60 mL/min or lower among 821 patients (72%), of whom 345 (42%) improved, 196 (24%) worsened, and 280 (34%) had no change at 30 days. There were no differences in baseline age, body mass index, diabetes, chronic obstructive pulmonary disease, coronary artery disease, peripheral arterial disease, hypertension, pulmonary hypertension, renal or liver disease, New York Heart Association III/IV symptoms, transaortic gradient, left ventricular ejection fraction, or procedural characteristics. The group with improved eGFR had more women, nonsmokers, and a lower cardiac index. Those with worsening eGFR had a higher median Society of Thoracic Surgeons score and left ventricle mass. From 30 days to 1 year, those with improved e

  7. Prospective study on determinants of repeat attendance and attendance patterns in breast cancer screening using the Theory of Planned Behaviour.

    NARCIS (Netherlands)

    Drossaert, Constance H.C.; Boer, Hendrik; Seydel, E.R.

    2003-01-01

    This prospective study, using the Theory of Planned Behaviour (TPB) as a theoretical framework, was carried out to identify the determinants of repeat attendance and attendance patterns in organised breast screening. A group of 2657 women filled out a baseline questionnaire, approximately 8 weeks

  8. COPD association and repeatability of blood biomarkers in the ECLIPSE cohort

    Directory of Open Access Journals (Sweden)

    Dickens Jennifer A

    2011-11-01

    Full Text Available Abstract Background There is a need for biomarkers to better characterise individuals with COPD and to aid with the development of therapeutic interventions. A panel of putative blood biomarkers was assessed in a subgroup of the Evaluation of COPD Longitudinally to Identify Surrogate Endpoints (ECLIPSE cohort. Methods Thirty-four blood biomarkers were assessed in 201 subjects with COPD, 37 ex-smoker controls with normal lung function and 37 healthy non-smokers selected from the ECLIPSE cohort. Biomarker repeatability was assessed using baseline and 3-month samples. Intergroup comparisons were made using analysis of variance, repeatability was assessed through Bland-Altman plots, and correlations between biomarkers and clinical characteristics were assessed using Spearman correlation coefficients. Results Fifteen biomarkers were significantly different in individuals with COPD when compared to former or non-smoker controls. Some biomarkers, including tumor necrosis factor-α and interferon-γ, were measurable in only a minority of subjects whilst others such as C-reactive protein showed wide variability over the 3-month replication period. Fibrinogen was the most repeatable biomarker and exhibited a weak correlation with 6-minute walk distance, exacerbation rate, BODE index and MRC dyspnoea score in COPD subjects. 33% (66/201 of the COPD subjects reported at least 1 exacerbation over the 3 month study with 18% (36/201 reporting the exacerbation within 30 days of the 3-month visit. CRP, fibrinogen interleukin-6 and surfactant protein-D were significantly elevated in those COPD subjects with exacerbations within 30 days of the 3-month visit compared with those individuals that did not exacerbate or whose exacerbations had resolved. Conclusions Only a few of the biomarkers assessed may be useful in diagnosis or management of COPD where the diagnosis is based on airflow obstruction (GOLD. Further analysis of more promising biomarkers may reveal

  9. System maintenance test plan for the TWRS controlled baseline database system

    International Nuclear Information System (INIS)

    Spencer, S.G.

    1998-01-01

    TWRS [Tank Waste Remediation System] Controlled Baseline Database, formally known as the Performance Measurement Control System, is used to track and monitor TWRS project management baseline information. This document contains the maintenance testing approach for software testing of the TCBD system once SCR/PRs are implemented

  10. Rule-of-thumb adjustment of sample sizes to accommodate dropouts in a two-stage analysis of repeated measurements.

    Science.gov (United States)

    Overall, John E; Tonidandel, Scott; Starbuck, Robert R

    2006-01-01

    Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.

  11. Repeating and non-repeating fast radio bursts from binary neutron star mergers

    Science.gov (United States)

    Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta

    2018-04-01

    Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.

  12. Safe and sensible preprocessing and baseline correction of pupil-size data.

    Science.gov (United States)

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    2018-02-01

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a baseline period. Baseline correction is useful in experiments that investigate the effect of some experimental manipulation on pupil size. In such experiments, baseline correction improves statistical power by taking into account random fluctuations in pupil size over time. However, we show that baseline correction can also distort data if unrealistically small pupil sizes are recorded during the baseline period, which can easily occur due to eye blinks, data loss, or other distortions. Divisive baseline correction (corrected pupil size = pupil size/baseline) is affected more strongly by such distortions than subtractive baseline correction (corrected pupil size = pupil size - baseline). We discuss the role of baseline correction as a part of preprocessing of pupillometric data, and make five recommendations: (1) before baseline correction, perform data preprocessing to mark missing and invalid data, but assume that some distortions will remain in the data; (2) use subtractive baseline correction; (3) visually compare your corrected and uncorrected data; (4) be wary of pupil-size effects that emerge faster than the latency of the pupillary response allows (within ±220 ms after the manipulation that induces the effect); and (5) remove trials on which baseline pupil size is unrealistically small (indicative of blinks and other distortions).

  13. 48 CFR 34.202 - Integrated Baseline Reviews.

    Science.gov (United States)

    2010-10-01

    ... or contractor, and the Government, of the— (1) Ability of the project's technical plan to achieve the... successfully achieve the project schedule objectives; (3) Ability of the Performance Measurement Baseline (PMB... SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION Earned Value Management System 34.202...

  14. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T 1 -weighted images (3D-T 1 WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  15. FINE-SCALE STRUCTURE OF THE QUASAR 3C 279 MEASURED WITH 1.3 mm VERY LONG BASELINE INTERFEROMETRY

    Energy Technology Data Exchange (ETDEWEB)

    Lu Rusen; Fish, Vincent L.; Doeleman, Sheperd S.; Crew, Geoffrey; Cappallo, Roger J. [Massachusetts Institute of Technology, Haystack Observatory, Route 40, Westford, MA 01886 (United States); Akiyama, Kazunori; Honma, Mareki [National Astronomical Observatory of Japan, Osawa 2-21-1, Mitaka, Tokyo 181-8588 (Japan); Algaba, Juan C.; Ho, Paul T. P.; Inoue, Makoto [Institute of Astronomy and Astrophysics, Academia Sinica, P.O. Box 23-141, Taipei 10617, Taiwan, R.O.C. (China); Bower, Geoffrey C.; Dexter, Matt [Department of Astronomy, Radio Astronomy Laboratory, University of California Berkeley, 601 Campbell, Berkeley, CA 94720-3411 (United States); Brinkerink, Christiaan [Department of Astrophysics, IMAPP, Radboud University Nijmegen, P.O. Box 9010, 6500-GL Nijmegen (Netherlands); Chamberlin, Richard [Caltech Submillimeter Observatory, 111 Nowelo Street, Hilo, HI 96720 (United States); Freund, Robert [Arizona Radio Observatory, Steward Observatory, University of Arizona, 933 North Cherry Avenue, Tucson, AZ 85721-0065 (United States); Friberg, Per [James Clerk Maxwell Telescope, Joint Astronomy Centre, 660 North A' ohoku Place, University Park, Hilo, HI 96720 (United States); Gurwell, Mark A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Jorstad, Svetlana G. [Institute for Astrophysical Research, Boston University, Boston, MA 02215 (United States); Krichbaum, Thomas P. [Max-Planck-Institut fuer Radioastronomie, Auf dem Huegel 69, D-53121 Bonn (Germany); Loinard, Laurent, E-mail: rslu@haystack.mit.edu [Centro de Radiostronomia y Astrofisica, Universidad Nacional Autonoma de Mexico, 58089 Morelia, Michoacan (Mexico); and others

    2013-07-20

    We report results from five day very long baseline interferometry observations of the well-known quasar 3C 279 at 1.3 mm (230 GHz) in 2011. The measured nonzero closure phases on triangles including stations in Arizona, California, and Hawaii indicate that the source structure is spatially resolved. We find an unusual inner jet direction at scales of {approx}1 pc extending along the northwest-southeast direction (P.A. = 127 Degree-Sign {+-} 3 Degree-Sign ), as opposed to other (previously) reported measurements on scales of a few parsecs showing inner jet direction extending to the southwest. The 1.3 mm structure corresponds closely with that observed in the central region of quasi-simultaneous super-resolution Very Long Baseline Array images at 7 mm. The closure phase changed significantly on the last day when compared with the rest of observations, indicating that the inner jet structure may be variable on daily timescales. The observed new direction of the inner jet shows inconsistency with the prediction of a class of jet precession models. Our observations indicate a brightness temperature of {approx}8 Multiplication-Sign 10{sup 10} K in the 1.3 mm core, much lower than that at centimeter wavelengths. Observations with better uv coverage and sensitivity in the coming years will allow the discrimination between different structure models and will provide direct images of the inner regions of the jet with 20-30 {mu}as (5-7 light months) resolution.

  16. FINE-SCALE STRUCTURE OF THE QUASAR 3C 279 MEASURED WITH 1.3 mm VERY LONG BASELINE INTERFEROMETRY

    International Nuclear Information System (INIS)

    Lu Rusen; Fish, Vincent L.; Doeleman, Sheperd S.; Crew, Geoffrey; Cappallo, Roger J.; Akiyama, Kazunori; Honma, Mareki; Algaba, Juan C.; Ho, Paul T. P.; Inoue, Makoto; Bower, Geoffrey C.; Dexter, Matt; Brinkerink, Christiaan; Chamberlin, Richard; Freund, Robert; Friberg, Per; Gurwell, Mark A.; Jorstad, Svetlana G.; Krichbaum, Thomas P.; Loinard, Laurent

    2013-01-01

    We report results from five day very long baseline interferometry observations of the well-known quasar 3C 279 at 1.3 mm (230 GHz) in 2011. The measured nonzero closure phases on triangles including stations in Arizona, California, and Hawaii indicate that the source structure is spatially resolved. We find an unusual inner jet direction at scales of ∼1 pc extending along the northwest-southeast direction (P.A. = 127° ± 3°), as opposed to other (previously) reported measurements on scales of a few parsecs showing inner jet direction extending to the southwest. The 1.3 mm structure corresponds closely with that observed in the central region of quasi-simultaneous super-resolution Very Long Baseline Array images at 7 mm. The closure phase changed significantly on the last day when compared with the rest of observations, indicating that the inner jet structure may be variable on daily timescales. The observed new direction of the inner jet shows inconsistency with the prediction of a class of jet precession models. Our observations indicate a brightness temperature of ∼8 × 10 10 K in the 1.3 mm core, much lower than that at centimeter wavelengths. Observations with better uv coverage and sensitivity in the coming years will allow the discrimination between different structure models and will provide direct images of the inner regions of the jet with 20-30 μas (5-7 light months) resolution.

  17. Influence of Baseline Psychological Health on Muscle Pain During Atorvastatin Treatment.

    Science.gov (United States)

    Zaleski, Amanda L; Taylor, Beth A; Pescatello, Linda S; Dornelas, Ellen A; White, Charles Michael; Thompson, Paul D

    3-hydroxy-3-methylglutaryl coenzyme A reductase reductase inhibitors (statins) are generally well tolerated, with statin-associated muscle symptoms (SAMS) the most common side effect (~10%) seen in statin users. However, studies and clinical observations indicate that many of the self-reported SAMS appear to be nonspecific (ie, potentially not attributable to statins). Mental health and well-being influence self-perception of pain, so we sought to assess the effect of baseline well-being and depression on the development of muscle pain with 6 months of atorvastatin 80 mg/d (ATORVA) or placebo in healthy, statin-naive adults. The Psychological General Well-being Index (n = 83) and Beck Depression Inventory (n = 55) questionnaires were administered at baseline in participants (aged 59.5 ± 1.2 years) from the effect of Statins on Skeletal Muscle Function and Performance (STOMP) trial (NCT00609063). Muscle pain (Short-Form McGill Pain Questionnaire [SF-MPQ]), pain that interferes with daily life (Brief Pain Inventory [BPI]), and pain severity (BPI) were then measured before, throughout, and after treatment. At baseline, there were no differences in well-being (Psychological General Well-being Index), depression (Beck Depression Inventory), or pain measures (SF-MPQ and BPI) (P values ≥ .05) between the placebo and ATORVA groups. Baseline well-being correlated negatively with baseline BPI pain severity (r = -0.290, P = .008). Baseline depression correlated with baseline pain (SF-MPQ; r = 0.314, P = .020). Baseline well-being and depression did not predict the change in pain severity or interference after 6 months among the total sample or between groups (P values ≥ .05). Baseline well-being and depression were not significant predictors of pain after 6 months of ATORVA (P values ≥ .05). Thus, they do not appear to increase the risk of SAMS in otherwise healthy adults.

  18. The method of contact angle measurements and estimation of work of adhesion in bioleaching of metals

    Directory of Open Access Journals (Sweden)

    Matlakowska Renata

    1999-01-01

    Full Text Available In this paper, we present our method for the measurement of contact angles on the surface of minerals during the bioleaching process because the standard deviation obtained in our measurements achieved unexpectedly low error. Construction of a goniometer connected with a specially prepared computer program allowed us to repeat measurements several times over a short time course, yielding excellent results. After defining points on the outline of the image of a drop and its baseline as well of the first approximation of the outline of the drop, an iterative process is initiated that is aimed at fitting the model of the drop and baseline. In turn, after defining the medium for which measurements were made, the work of adhesion is determined according to Young-Dupré equation. Calculations were made with the use of two methods named the L-M and L-Q methods.

  19. A passive heat maintenance strategy implemented during a simulated half-time improves lower body power output and repeated sprint ability in professional Rugby Union players.

    Directory of Open Access Journals (Sweden)

    Mark Russell

    Full Text Available Reduced physical performance has been observed following the half-time period in team sports players, likely due to a decrease in muscle temperature during this period. We examined the effects of a passive heat maintenance strategy employed between successive exercise bouts on core temperature (Tcore and subsequent exercise performance. Eighteen professional Rugby Union players completed this randomised and counter-balanced study. After a standardised warm-up (WU and 15 min of rest, players completed a repeated sprint test (RSSA 1 and countermovement jumps (CMJ. Thereafter, in normal training attire (Control or a survival jacket (Passive, players rested for a further 15 min (simulating a typical half-time before performing a second RSSA (RSSA 2 and CMJ's. Measurements of Tcore were taken at baseline, post-WU, pre-RSSA 1, post-RSSA 1 and pre-RSSA 2. Peak power output (PPO and repeated sprint ability was assessed before and after the simulated half-time. Similar Tcore responses were observed between conditions at baseline (Control: 37.06±0.05°C; Passive: 37.03±0.05°C and for all other Tcore measurements taken before half-time. After the simulated half-time, the decline in Tcore was lower (-0.74±0.08% vs. -1.54±0.06%, p<0.001 and PPO was higher (5610±105 W vs. 5440±105 W, p<0.001 in the Passive versus Control condition. The decline in PPO over half-time was related to the decline in Tcore (r = 0.632, p = 0.005. In RSSA 2, best, mean and total sprint times were 1.39±0.17% (p<0.001, 0.55±0.06% (p<0.001 and 0.55±0.06% (p<0.001 faster for Passive versus Control. Passive heat maintenance reduced declines in Tcore that were observed during a simulated half-time period and improved subsequent PPO and repeated sprint ability in professional Rugby Union players.

  20. Increased Risk of Progression of Coronary Artery Calcification in Male Subjects with High Baseline Waist-to-Height Ratio: The Kangbuk Samsung Health Study.

    Science.gov (United States)

    Oh, Hyung Geun; Nallamshetty, Shriram; Rhee, Eun Jung

    2016-02-01

    The waist-to-height ratio (WHtR) is an easy and inexpensive adiposity index that reflects central obesity. In this study, we examined the association of baseline WHtR and progression of coronary artery calcification (CAC) over 4 years of follow-up in apparently healthy Korean men. A total of 1,048 male participants (mean age, 40.9 years) in a health-screening program in Kangbuk Samsung Hospital, Seoul, Korea who repeated a medical check-up in 2010 and 2014 were recruited. Baseline WHtR was calculated using the value for the waist in 2010 divided by the value for height in 2010. The CAC score (CACS) of each subject was measured by multi-detector computed tomography in both 2010 and 2014. Progression of CAC was defined as a CACS change over 4 years greater than 0. During the follow-up period, progression of CAC occurred in 278 subjects (26.5%). The subjects with CAC progression had slightly higher but significant baseline WHtR compared to those who did not show CAC progression (0.51±0.04 vs. 0.50±0.04, P<0.01). The proportion of subjects with CAC progression significantly increased as the baseline WHtR increased from the 1st quartile to 4th quartile groups (18.3%, 18.7%, 28.8%, and 34.2%; P<0.01). The risk for CAC progression was elevated with an odds ratio of 1.602 in the 4th quartile group of baseline WHtR even after adjustment for confounding variables (95% confidence interval, 1.040 to 2.466). Increased baseline WHtR was associated with increased risk for CAC progression. WHtR might be a useful screening tool to identify individuals at high risk for subclinical atherosclerosis.

  1. Ground level measurement of nuclei from coal development in the northern Great Plains: baseline measurements. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Davis, B. L.; Johnson, L. R.; Sengupta, S.; Yue, P. C.

    1978-11-01

    The Institute of Atmospheric Sciences of the South Dakota School of Mines and Technology has completed 20 months of ambient air sampling at rural and remote sites in a five-state region of the northern Great Plains. Sampling was accomplished by use of a 27-ft motor home laboratory containing living accommodations for a field crew of two. The laboratory was outfitted with a number of instruments for measurement of pollutant parameters: cloud condensation nuclei, ice nuclei, Aitken nuclei, size distribution information for Aitken size particulate, sulfur dioxide, ozone, raindrop size distributions, and pH of precipitation. In addition, an instrumented meteorological tower provided wind speed, wind direction, ambient air temperature, and dew-point temperature. Instruments varied as to durability and success of operation, but better than 90% data retrieval was possible for the entire 20-month sampling study. Analyses of the large quantities of data obtained were not possible under the initial baseline measurement program, but examination of most parameters indicate that the air masses in the northern Great Plains are still relatively clean and are influenced primarily by local sources of contamination rather than large regional sources. Particulate concentrations in these remote areas are representative of mountain stations or clean rural conditions, and sulfur dioxide concentrations are at the threshold of detectability of the instrument. Precipitation is only very slightly acidic, and no significant quantity of amorphous particles (such as coal dust or combustion products) is found in the quantitative analyses of the high-volume filter collections. A summary of ''average'' conditions observed over the study area is tabulated.

  2. Discontinuous Patterns of Cigarette Smoking From Ages 18 to 50 in the United States: A Repeated-Measures Latent Class Analysis.

    Science.gov (United States)

    Terry-McElrath, Yvonne M; O'Malley, Patrick M; Johnston, Lloyd D

    2017-12-13

    Effective cigarette smoking prevention and intervention programming is enhanced by accurate understanding of developmental smoking pathways across the life span. This study investigated within-person patterns of cigarette smoking from ages 18 to 50 among a US national sample of high school graduates, focusing on identifying ages of particular importance for smoking involvement change. Using data from approximately 15,000 individuals participating in the longitudinal Monitoring the Future study, trichotomous measures of past 30-day smoking obtained at 11 time points were modeled using repeated-measures latent class analyses. Sex differences in latent class structure and membership were examined. Twelve latent classes were identified: three characterized by consistent smoking patterns across age (no smoking; smoking developing effective smoking prevention and intervention programming. This study examined cigarette smoking among a national longitudinal US sample of high school graduates from ages 18 to 50 and identified distinct latent classes characterized by patterns of movement between no cigarette use, light-to-moderate smoking, and the conventional definition of heavy smoking at 11 time points via repeated-measures latent class analysis. Membership probabilities for each smoking class were estimated, and critical ages of susceptibility to change in smoking behaviors were identified. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Who Repeats Algebra, and How Does Initial Performance Relate to Improvement When the Course Is Repeated?

    Science.gov (United States)

    Fong, Anthony; Jaquet, Karina; Finkelstein, Neal

    2016-01-01

    The information provided in this report shows how students perform when they repeat algebra I and how the level of improvement varies depending on initial course performance and the academic measure (course grades or CST scores). This information can help inform decisions and policies regarding whether and under what circumstances students should…

  4. Toward a simple, repeatable, non-destructive approach to measuring stable-isotope ratios of water within tree stems

    Science.gov (United States)

    Raulerson, S.; Volkmann, T.; Pangle, L. A.

    2017-12-01

    Traditional methodologies for measuring ratios of stable isotopes within the xylem water of trees involve destructive coring of the stem. A recent approach involves permanently installed probes within the stem, and an on-site assembly of pumps, switching valves, gas lines, and climate-controlled structure for field deployment of a laser spectrometer. The former method limits the possible temporal resolution of sampling, and sample size, while the latter may not be feasible for many research groups. We present results from initial laboratory efforts towards developing a non-destructive, temporally-resolved technique for measuring stable isotope ratios within the xylem flow of trees. Researchers have used direct liquid-vapor equilibration as a method to measure isotope ratios of the water in soil pores. Typically, this is done by placing soil samples in a fixed container, and allowing the liquid water within the soil to come into isotopic equilibrium with the headspace of the container. Water can also be removed via cryogenic distillation or azeotropic distillation, with the resulting liquid tested for isotope ratios. Alternatively, the isotope ratios of the water vapor can be directly measured using a laser-based water vapor isotope analyzer. Well-established fractionation factors and the isotope ratios in the vapor phase are then used to calculate the isotope ratios in the liquid phase. We propose a setup which would install a single, removable chamber onto a tree, where vapor samples could non-destructively and repeatedly be taken. These vapor samples will be injected into a laser-based isotope analyzer by a recirculating gas conveyance system. A major part of what is presented here is in the procedure of taking vapor samples at 100% relative humidity, appropriately diluting them with completely dry N2 calibration gas, and injecting them into the gas conveyance system without inducing fractionation in the process. This methodology will be helpful in making

  5. Neutrino physics with short baseline experiments

    International Nuclear Information System (INIS)

    Zimmerman, E.D.

    2006-01-01

    Neutrino physics with low- to medium-energy beams has progressed steadily over the last several years. Neutrino oscillation searches at short baseline (defined as 2 - -> 0.1eV 2 . One positive signal, from the LSND collaboration, exists and is being tested by the MiniBooNE experiment. Neutrino cross-section measurements are being made by MiniBooNE and K2K, which will be important for reducing systematic errors in present and future oscillation measurements. In the near future, dedicated cross- section experiments will begin operating at Fermilab. (author)

  6. Narrative exposure therapy for posttraumatic stress disorder associated with repeated interpersonal trauma in patients with severe mental illness: a mixed methods design

    Directory of Open Access Journals (Sweden)

    Maria W. Mauritz

    2016-09-01

    Full Text Available Background: In the Netherlands, most patients with severe mental illness (SMI receive flexible assertive community treatment (FACT provided by multidisciplinary community mental health teams. SMI patients with comorbid posttraumatic stress disorder (PTSD are sometimes offered evidence-based trauma-focused treatment like eye movement desensitization reprocessing or prolonged exposure. There is a large amount of evidence for the effectiveness of narrative exposure therapy (NET within various vulnerable patient groups with repeated interpersonal trauma. Some FACT-teams provide NET for patients with comorbid PTSD, which is promising, but has not been specifically studied in SMI patients. Objectives: The primary aim is to evaluate NET in SMI patients with comorbid PTSD associated with repeated interpersonal trauma to get insight into whether (1 PTSD and dissociative symptoms changes and (2 changes occur in the present SMI symptoms, care needs, quality of life, global functioning, and care consumption. The second aim is to gain insight into patients’ experiences with NET and to identify influencing factors on treatment results. Methods: This study will have a mixed methods convergent design consisting of quantitative repeated measures and qualitative semi-structured in-depth interviews based on Grounded Theory. The study population will include adult SMI outpatients (n=25 with comorbid PTSD and receiving NET. The quantitative study parameters will be existence and severity of PTSD, dissociative, and SMI symptoms; care needs; quality of life; global functioning; and care consumption. In a longitudinal analysis, outcomes will be analyzed using mixed models to estimate the difference in means between baseline and repeated measurements. The qualitative study parameters will be experiences with NET and perceived factors for success or failure. Integration of quantitative and qualitative results will be focused on interpreting how qualitative results

  7. Governing conditions of repeatable Barkhausen noise response

    International Nuclear Information System (INIS)

    Stupakov, O.; Pal'a, J.; Takagi, T.; Uchimoto, T.

    2009-01-01

    The paper is devoted to the establishment of experimental conditions, which ensure the repeatability of magnetic Barkhausen noise testing in practice. For this task, the measurements were performed on open flat samples using different experimental configurations, including: different magnetization frequencies, sampling rates, and filter cut-off frequencies; using a sample-wrapped coil and using attached pick-up coils of various dimensions, with different lift-offs of a single yoke magnet and of the attached coil. The sample magnetization was controlled by a vertical array of three Hall sensors; their readings were extrapolated to the sample surface to precisely define its field. After analysis of the results, a scheme for an optimized sensor with a controlled field waveform was suggested to improve the measurement repeatability. The important issues of signal processing and parameter applicability were also discussed in detail.

  8. Baseline methodologies for clean development mechanism projects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M.K. (ed.); Shrestha, R.M.; Sharma, S.; Timilsina, G.R.; Kumar, S.

    2005-11-15

    The Kyoto Protocol and the Clean Development Mechanism (CDM) came into force on 16th February 2005 with its ratification by Russia. The increasing momentum of this process is reflected in more than 100 projects having been submitted to the CDM Executive Board (CDM-EB) for approval of the baselines and monitoring methodologies, which is the first step in developing and implementing CDM projects. A CDM project should result in a net decrease of GHG emissions below any level that would have resulted from other activities implemented in the absence of that CDM project. The 'baseline' defines the GHG emissions of activities that would have been implemented in the absence of a CDM project. The baseline methodology is the process/algorithm for establishing that baseline. The baseline, along with the baseline methodology, are thus the most critical element of any CDM project towards meeting the important criteria of CDM, which are that a CDM should result in 'real, measurable, and long term benefits related to the mitigation of climate change'. This guidebook is produced within the frame work of the United Nations Environment Programme (UNEP) facilitated 'Capacity Development for the Clean Development Mechanism (CD4CDM)' Project. This document is published as part of the projects effort to develop guidebooks that cover important issues such as project finance, sustainability impacts, legal framework and institutional framework. These materials are aimed to help stakeholders better understand the CDM and are believed to eventually contribute to maximize the effect of the CDM in achieving the ultimate goal of UNFCCC and its Kyoto Protocol. This Guidebook should be read in conjunction with the information provided in the two other guidebooks entitled, 'Clean Development Mechanism: Introduction to the CDM' and 'CDM Information and Guidebook' developed under the CD4CDM project. (BA)

  9. Baseline methodologies for clean development mechanism projects

    International Nuclear Information System (INIS)

    Lee, M.K.; Shrestha, R.M.; Sharma, S.; Timilsina, G.R.; Kumar, S.

    2005-11-01

    The Kyoto Protocol and the Clean Development Mechanism (CDM) came into force on 16th February 2005 with its ratification by Russia. The increasing momentum of this process is reflected in more than 100 projects having been submitted to the CDM Executive Board (CDM-EB) for approval of the baselines and monitoring methodologies, which is the first step in developing and implementing CDM projects. A CDM project should result in a net decrease of GHG emissions below any level that would have resulted from other activities implemented in the absence of that CDM project. The 'baseline' defines the GHG emissions of activities that would have been implemented in the absence of a CDM project. The baseline methodology is the process/algorithm for establishing that baseline. The baseline, along with the baseline methodology, are thus the most critical element of any CDM project towards meeting the important criteria of CDM, which are that a CDM should result in 'real, measurable, and long term benefits related to the mitigation of climate change'. This guidebook is produced within the frame work of the United Nations Environment Programme (UNEP) facilitated 'Capacity Development for the Clean Development Mechanism (CD4CDM)' Project. This document is published as part of the projects effort to develop guidebooks that cover important issues such as project finance, sustainability impacts, legal framework and institutional framework. These materials are aimed to help stakeholders better understand the CDM and are believed to eventually contribute to maximize the effect of the CDM in achieving the ultimate goal of UNFCCC and its Kyoto Protocol. This Guidebook should be read in conjunction with the information provided in the two other guidebooks entitled, 'Clean Development Mechanism: Introduction to the CDM' and 'CDM Information and Guidebook' developed under the CD4CDM project. (BA)

  10. A Unified Model for Repeating and Non-repeating Fast Radio Bursts

    International Nuclear Information System (INIS)

    Bagchi, Manjari

    2017-01-01

    The model that fast radio bursts (FRBs) are caused by plunges of asteroids onto neutron stars can explain both repeating and non-repeating bursts. If a neutron star passes through an asteroid belt around another star, there would be a series of bursts caused by a series of asteroid impacts. Moreover, the neutron star would cross the same belt repetitively if it were in a binary with the star hosting the asteroid belt, leading to a repeated series of bursts. I explore the properties of neutron star binaries that could lead to the only known repeating FRB so far (FRB121102). In this model, the next two epochs of bursts are expected around 2017 February 27 and 2017 December 18. On the other hand, if the asteroid belt is located around the neutron star itself, then a chance fall of an asteroid from that belt onto the neutron star would lead to a non-repeating burst. Even a neutron star grazing an asteroid belt can lead to a non-repeating burst caused by just one asteroid plunge during the grazing. This is possible even when the neutron star is in a binary with the asteroid-hosting star, if the belt and the neutron star orbit are non-coplanar.

  11. A Unified Model for Repeating and Non-repeating Fast Radio Bursts

    Energy Technology Data Exchange (ETDEWEB)

    Bagchi, Manjari, E-mail: manjari@imsc.res.in [The Institute of Mathematical Sciences (IMSc-HBNI), 4th Cross Road, CIT Campus, Taramani, Chennai 600113 (India)

    2017-04-01

    The model that fast radio bursts (FRBs) are caused by plunges of asteroids onto neutron stars can explain both repeating and non-repeating bursts. If a neutron star passes through an asteroid belt around another star, there would be a series of bursts caused by a series of asteroid impacts. Moreover, the neutron star would cross the same belt repetitively if it were in a binary with the star hosting the asteroid belt, leading to a repeated series of bursts. I explore the properties of neutron star binaries that could lead to the only known repeating FRB so far (FRB121102). In this model, the next two epochs of bursts are expected around 2017 February 27 and 2017 December 18. On the other hand, if the asteroid belt is located around the neutron star itself, then a chance fall of an asteroid from that belt onto the neutron star would lead to a non-repeating burst. Even a neutron star grazing an asteroid belt can lead to a non-repeating burst caused by just one asteroid plunge during the grazing. This is possible even when the neutron star is in a binary with the asteroid-hosting star, if the belt and the neutron star orbit are non-coplanar.

  12. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-12-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation (MLI) has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five Glenn Research Center (GRC) provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons has been fabricated by Yetispace and tested by Florida State University, the repeatability between coupons has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  13. Space geodetic observations of repeating slow slip events beneath the Bonin Islands

    Science.gov (United States)

    Arisa, Deasy; Heki, Kosuke

    2017-09-01

    The Pacific Plate subducts beneath the Philippine Sea Plate along the Izu-Bonin Trench. We investigated crustal movements at the Bonin Islands, using Global Navigation Satellite System and geodetic Very Long Baseline Interferometry data to reveal how the two plates converge in this subduction zone. These islands are located ∼100 km from the trench, just at the middle between the volcanic arc and the trench, making these islands suitable for detecting signatures of episodic deformation such as slow slip events (SSEs). During 2007-2016, we found five SSEs repeating quasi-periodically with similar displacement patterns. In estimating their fault parameters, we assumed that the fault lies on the prescribed plate boundary, and optimized the size, shape and position of the fault and dislocation vectors. Average fault slip was ∼5 cm, and the average moment magnitude was ∼6.9. We also found one SSE occurred in 2008 updip of the repeating SSE in response to an M6 class interplate earthquake. In spite of the frequent occurrence of SSEs, there is no evidence for long-term strain accumulation in the Bonin Islands that may lead to future megathrust earthquakes. Plate convergence in Mariana-type subduction zones may occur, to a large extent, episodically as repeating SSEs.

  14. The rise in carboxyhemoglobin from repeated pulmonary diffusing capacity tests.

    Science.gov (United States)

    Zavorsky, Gerald S

    2013-03-01

    The purpose of this study determined the rise in carboxyhemoglobin percentage (COHb) from repeated pulmonary diffusing capacity tests using 5 or 10s single breath-hold maneuvers. Five male and four female non-smokers [baseline COHb=1.2 (SD 0.5%)] performed repeated pulmonary diffusing capacity testing on two separate days. The days were randomized to either repeated 10s (0.28% CO), or 5s (0.28% CO, 55ppm NO) breath-hold maneuvers. Twenty-two 5s breath-hold maneuvers, each separated by 4min rest, raised COHb to 11.1 (1.4)% and minimally raised the methemoglobin percentage (METHb) by 0.3 (0.2)% to a value of 0.8 (0.2)%. After the 22nd test, pulmonary diffusing capacity for carbon monoxide (DLCO) was reduced by about 4mL/min/mmHg, equating to a 0.44% increase in COHb per 5s breath-hold maneuver and a concomitant 0.35mL/min/mmHg decrease in DLCO. Pulmonary diffusing capacity for nitric oxide (DLNO) was not altered after 22 tests. On another day, the 10s single breath-hold maneuver increased COHb by 0.64% per test, and reduced DLCO by 0.44mL/min/mmHg per test. In conclusion, 5s breath-hold maneuvers do not appreciably raise METHb or DLNO, and DLCO is only significantly reduced when COHb is at least 6%. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

    Science.gov (United States)

    Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo

    2015-01-01

    To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  16. Repeated Geophysical Surface Measurements to Estimate the Dynamics of Underground Coalfires

    Science.gov (United States)

    Wuttke, M. W.; Kessels, W.; Han, J.; Halisch, M.; Rüter, H.; Lindner, H.

    2009-04-01

    in a range between -130 and 176 nT. The maxima are most likely caused by the conversion of pyrite and markasit into maghemite, hematite and magnetite. Therefore the identified patches with high magnetic anomalies should have a direct connection to the burning coal in firezone 18. The firezone in Wuda has been visited now for five, that in Queergou for two times. All the discussed geophysical measurements together allow an integrated interpretation. Each result can be related to the combustion process with a particular likelihood for the vertical projection to the combustion centre. Probability calculations with chosen weight factors for each observation method are discussed. A so called fireindex deduced from the repeated measurements reveals the dynamics of the coal fire.

  17. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    evaluating the deployment repeatability builds upon the testing or analysis of deployment kinematics (Chapter 6) and adds repetition. Introduction...material yield or failure during a test. For the purposes of this chapter, zero shift will refer to permanent changes in the structure, while reversible ...the content of other chapters in this book: Gravity Compensation (Chapter 4) and Deployment Kinematics and Dynamics (Chapter 6). Repeating the

  18. Test–retest repeatability of quantitative cardiac 11C-meta-hydroxyephedrine measurements in rats by small animal positron emission tomography

    International Nuclear Information System (INIS)

    Thackeray, James T.; Renaud, Jennifer M.; Kordos, Myra; Klein, Ran; Kemp, Robert A. de; Beanlands, Rob S.B.; DaSilva, Jean N.

    2013-01-01

    Introduction: The norepinephrine analogue 11 C-meta-hydroxyephedrine (HED) has been used to interrogate sympathetic neuronal reuptake in cardiovascular disease. Application for longitudinal studies in small animal models of disease necessitates an understanding of test–retest variability. This study evaluated the repeatability of multiple quantitative cardiac measurements of HED retention and washout and the pharmacological response to reuptake blockade and enhanced norepinephrine levels. Methods: Small animal PET images were acquired over 60 min following HED administration to healthy male Sprague Dawley rats. Paired test and retest scans were undertaken in individual animals over 7 days. Additional HED scans were conducted following administration of norepinephrine reuptake inhibitor desipramine or continuous infusion of exogenous norepinephrine. HED retention was quantified by retention index, standardized uptake value (SUV), monoexponential and one-compartment washout. Plasma and cardiac norepinephrine were measured by high performance liquid chromatography. Results: Test retest variability was lower for retention index (15% ± 12%) and SUV (19% ± 15%) as compared to monoexponential washout rates (21% ± 13%). Desipramine pretreatment reduced myocardial HED retention index by 69% and SUV by 85%. Chase treatment with desipramine increased monoexponential HED washout by 197% compared to untreated controls. Norepinephrine infusion dose-dependently reduced HED accumulation, reflected by both retention index and SUV, with a corresponding increase in monoexponential washout. Plasma and cardiac norepinephrine levels correlated with HED quantitative measurements. Conclusion: The repeatability of HED retention index, SUV, and monoexponential washout supports its suitability for longitudinal PET studies in rats. Uptake and washout of HED are sensitive to acute increases in norepinephrine concentration

  19. Heat stress impairs repeated jump ability after competitive elite soccer games

    DEFF Research Database (Denmark)

    Mohr, Magni; Krustrup, Peter

    2013-01-01

    ABSTRACT:: The present study examined the effect of environmental heat stress on repeated jump performance after elite competitive soccer games. Male elite soccer players (n=19) from two Scandinavian teams participated (age; 26.7±1.0 yrs, height; 181.7±1.1 cm, body mass; 75.8±1.0 kg). The players...... had a Yo-Yo IR2 performance of 1032±42 m (range: 920-1400 m). The players took part in the Champions League Qualification (CL), where six games (three home and three away) were played. The home games took place at an average ambient temperature of 12.2±0.5 oC (control game; CON) and the away games...... in hot conditions (30.0±0.3 oC; HOT). In resting condition (Baseline) and immediately after CON and HOT, the players performed a repeated countermovement jump (CMJ) test consisting of five jumps separated by 10 s of recovery. Game-induced body mass loss was determined based on change in body mass after...

  20. Repeated assessments of symptom severity improve predictions for risk of death among patients with cancer.

    Science.gov (United States)

    Sutradhar, Rinku; Atzema, Clare; Seow, Hsien; Earle, Craig; Porter, Joan; Barbera, Lisa

    2014-12-01

    Although prior studies show the importance of self-reported symptom scores as predictors of cancer survival, most are based on scores recorded at a single point in time. To show that information on repeated assessments of symptom severity improves predictions for risk of death and to use updated symptom information for determining whether worsening of symptom scores is associated with a higher hazard of death. This was a province-based longitudinal study of adult outpatients who had a cancer diagnosis and had assessments of symptom severity. We implemented a time-to-death Cox model with a time-varying covariate for each symptom to account for changing symptom scores over time. This model was compared with that using only a time-fixed (baseline) covariate for each symptom. The regression coefficients of each model were derived based on a randomly selected 60% of patients, and then, the predictive performance of each model was assessed via concordance probabilities when applied to the remaining 40% of patients. This study had 66,112 patients diagnosed with cancer and more than 310,000 assessments of symptoms. The use of repeated assessments of symptom scores improved predictions for risk of death compared with using only baseline symptom scores. Increased pain and fatigue and reduced appetite were the strongest predictors for death. If available, researchers should consider including changing information on symptom scores, as opposed to only baseline information on symptom scores, when examining hazard of death among patients with cancer. Worsening of pain, fatigue, and appetite may be a flag for impending death. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  1. NA61/SHINE Data For Long Baseline Neutrino Experiments

    CERN Document Server

    Hälser, Alexis

    2015-01-01

    Accelerator based long baseline neutrino experiments require precise neutrino fl ux predictions to reach their physics goals. These experiments are commonly based on a set of two detectors. At the near detector, cross section measurements are performed and the neutrino fl ux can be observed before oscillation, while at the far detector the signal for neutrino oscillations is studied. An accurate knowledge on hadron production is mandatory in order to predict the neutrino fluxes. The NA61/SHINE facility at the CERN SPS has proven its ability to deliver high quality measurements of hadron production for the long baseline neutrino experiments. In this paper, the latest results from N A61 /SHINE for the neutrino physics programme are reviewed and future plans are presented.

  2. Testing Mean Differences among Groups: Multivariate and Repeated Measures Analysis with Minimal Assumptions.

    Science.gov (United States)

    Bathke, Arne C; Friedrich, Sarah; Pauly, Markus; Konietschke, Frank; Staffen, Wolfgang; Strobl, Nicolas; Höller, Yvonne

    2018-03-22

    To date, there is a lack of satisfactory inferential techniques for the analysis of multivariate data in factorial designs, when only minimal assumptions on the data can be made. Presently available methods are limited to very particular study designs or assume either multivariate normality or equal covariance matrices across groups, or they do not allow for an assessment of the interaction effects across within-subjects and between-subjects variables. We propose and methodologically validate a parametric bootstrap approach that does not suffer from any of the above limitations, and thus provides a rather general and comprehensive methodological route to inference for multivariate and repeated measures data. As an example application, we consider data from two different Alzheimer's disease (AD) examination modalities that may be used for precise and early diagnosis, namely, single-photon emission computed tomography (SPECT) and electroencephalogram (EEG). These data violate the assumptions of classical multivariate methods, and indeed classical methods would not have yielded the same conclusions with regards to some of the factors involved.

  3. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  4. Increasing the Accuracy in the Measurement of the Minor Isotopes of Uranium: Care in Selection of Reference Materials, Baselines and Detector Calibration

    Science.gov (United States)

    Poths, J.; Koepf, A.; Boulyga, S. F.

    2008-12-01

    The minor isotopes of uranium (U-233, U-234, U-236) are increasingly useful for tracing a variety of processes: movement of anthropogenic nuclides in the environment (ref 1), sources of uranium ores (ref 2), and nuclear material attribution (ref 3). We report on improved accuracy for U-234/238 and U-236/238 by supplementing total evaporation protocol TIMS measurement on Faraday detectors (ref 4)with multiplier measurement for the minor isotopes. Measurement of small signals on Faraday detectors alone is limited by noise floors of the amplifiers and accurate measurement of the baseline offsets. The combined detector approach improves the reproducibility to better than ±1% (relative) for the U-234/238 at natural abundance, and yields a detection limit for U-236/U-238 of <0.2 ppm. We have quantified contribution of different factors to the uncertainties associated with these peak jumping measurement on a single detector, with an aim of further improvement. The uncertainties in the certified values for U-234 and U-236 in the uranium standard NBS U005, if used for mass bias correction, dominates the uncertainty in their isotopic ratio measurements. Software limitations in baseline measurement drives the detection limit for the U-236/U-238 ratio. This is a topic for discussion with the instrument manufacturers. Finally, deviation from linearity of the response of the electron multiplier with count rate limits the accuracy and reproducibility of these minor isotope measurements. References: (1) P. Steier et al(2008) Nuc Inst Meth(B), 266, 2246-2250. (2) E. Keegan et al (2008) Appl Geochem 23, 765-777. (3) K. Mayer et al (1998) IAEA-CN-98/11, in Advances in Destructive and Non-destructive Analysis for Environmental Monitoring and Nuclear Forensics. (4) S. Richter and S. Goldberg(2003) Int J Mass Spectrom, 229, 181-197.

  5. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  6. Repeated measurements of NT-pro-B-type natriuretic peptide, troponin T or C-reactive protein do not predict future allograft rejection in heart transplant recipients.

    Science.gov (United States)

    Battes, Linda C; Caliskan, Kadir; Rizopoulos, Dimitris; Constantinescu, Alina A; Robertus, Jan L; Akkerhuis, Martijn; Manintveld, Olivier C; Boersma, Eric; Kardys, Isabella

    2015-03-01

    Studies on the prognostic value of serial biomarker assays for future occurrence of allograft rejection (AR) are scarce. We examined whether repeated measurements of NT-pro-B-type natriuretic peptide (NT-proBNP), troponin T (TropT) and C-reactive protein (CRP) predict AR. From 2005 to 2010, 77 consecutive heart transplantation (HTx) recipients were included. The NT-proBNP, TropT, and CRP were measured at 16 ± 4 (mean ± standard deviation) consecutive routine endomyocardial biopsy surveillance visits during the first year of follow-up. Allograft rejection was defined as International Society for Heart and Lung Transplantation (ISHLT) grade 2R or higher at endomyocardial biopsy. Joint modeling was used to assess the association between repeated biomarker measurements and occurrence of future AR. Joint modeling accounts for dependence among repeated observations in individual patients. The mean age of the patients at HTx was 49 ± 9.2 years, and 68% were men. During the first year of follow-up, 1,136 biopsies and concurrent blood samples were obtained, and 56 patients (73%) experienced at least one episode of AR. All biomarkers were elevated directly after HTx and achieved steady-state after ∼ 12 weeks, both in patients with or without AR. No associations were present between the repeated measurements of NT-proBNP, TropT, or CRP and AR both early (weeks 0-12) and late (weeks 13-52) in the course after HTx (hazard ratios for weeks 13-52: 0.96 (95% confidence interval, 0.55-1.68), 0.67 (0.27-1.69), and 1.44 (0.90-2.30), respectively, per ln[unit]). Combining the three biomarkers in one model also rendered null results. The temporal evolution of NT-proBNP, TropT, and CRP before AR did not predict occurrence of acute AR both in the early and late course of the first year after HTx.

  7. Superficial ultrasound shear wave speed measurements in soft and hard elasticity phantoms: repeatability and reproducibility using two ultrasound systems.

    Science.gov (United States)

    Dillman, Jonathan R; Chen, Shigao; Davenport, Matthew S; Zhao, Heng; Urban, Matthew W; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L

    2015-03-01

    There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. To assess the repeatability and reproducibility of superficial shear wave speed measurements acquired from elasticity phantoms at varying imaging depths using three imaging methods, two US systems and multiple operators. Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems Inc. (Norfolk, VA) were utilized for our investigation. Institution No. 1 used an Acuson S3000 US system (Siemens Medical Solutions USA, Malvern, PA) and three shear wave imaging method/transducer combinations, while institution No. 2 used an Aixplorer US system (SuperSonic Imagine, Bothell, WA) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0 cm, 2.5 cm and 4.0 cm) by four operators at each institution. Student's t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single-measure intra-class correlation coefficients (ICCs) and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (P = 0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (P > 0.05). The coefficients of variation were low (0.5-6.8%), and interoperator agreement was near-perfect (ICCs ≥ 0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (P

  8. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  9. The effect of mere measurement from a cardiovascular examination program on physical activity and sedentary time in an adult population.

    Science.gov (United States)

    Voigt, Lisa; Baumann, Sophie; Ullrich, Antje; Weymar, Franziska; John, Ulrich; Ulbricht, Sabina

    2018-01-01

    Measuring physical activity (PA) and sedentary time (ST) by self-report or device as well as assessing related health factors may alter those behaviors. Thus, in intervention trials assessments may bias intervention effects. The aim of our study was to examine whether leisure-time PA, transport-related PA, and overall ST measured via self-report vary after assessments and whether a brief tailored letter intervention has an additional effect. Among a sample of subjects with no history of myocardial infarction, stroke, or vascular intervention, a number of 175 individuals participated in a study comprising multiple repeated assessments. Of those, 153 were analyzed (mean age 54.5 years, standard deviation = 6.2; 64% women). At baseline, participants attended a cardiovascular examination (standardized measurement of blood pressure and waist circumference, blood sample taking) and wore an accelerometer for seven days. At baseline and after 1, 6, and 12 months, participants completed the International Physical Activity Questionnaire. A random subsample received a tailored counseling letter intervention at month 1, 3, and 4. Changes in PA and ST from baseline to 12-month follow-up were analyzed using random-effects modelling. From baseline to 1-month assessment, leisure-time PA did not change (Incidence rate ratio = 1.13, p  = .432), transport-related PA increased (Incidence rate ratio = 1.45, p  = .023), and overall ST tended to decrease (b = - 1.96, p  = .060). Further, overall ST decreased from month 6 to month 12 (b = - 0.52, p  = .037). Time trends of the intervention group did not differ significantly from those of the assessment-only group. Results suggest an effect of measurements on PA and ST. Data of random-effects modelling results revealed an increase of transport-related PA after baseline to 1-month assessment. Decreases in overall ST may result from repeated assessments. A brief tailored letter intervention seemed to

  10. Improved recovery of repeat intoxicated drivers using fingernails and blood spots to monitor alcohol and other substance abuse.

    Science.gov (United States)

    Bean, Pamela; Brown, Guida; Hallinan, Patricia; Becerra, Sergio; Lewis, Doug

    2017-01-02

    This study reports the results of a pilot program in Kenosha County that used a combination of direct biomarkers extracted from blood spots and nails to monitor repeat intoxicated drivers for their use of alcohol and drugs with a detection window spanning from 3 weeks to several months. The objectives were to test whether the direct biomarkers phosphatidylethanol (PEth), ethylglucuronide (EtG), and 5 drug metabolites would (1) help assessors obtain a more objective evaluation of repeat offenders during the assessment interview, (2) allow for timely identification of relapses and improve classification of drivers into risk categories, and (3) predict recidivism by identifying offenders most likely to obtain a subsequent operating while intoxicated (OWI) offense within 4 years of enrollment in the program. All (N = 261) repeat offenders were tested using PEth obtained from blood spots and EtG obtained from fingernails; 159 participants were also tested for a 5 drugs of abuse nail panel. Drivers were tested immediately after the assessment interview (baseline) and at 3, 6, 9, and 12 months after baseline. Based on biomarker results and self-reports of abstinence, offenders were classified into different risk categories and required to follow specific testing timelines based on the program's decision tree. The baseline analysis shows that 60% of drivers tested positive for alcohol biomarkers (EtG, PEth, or both) at the assessment interview, with lower detection rates (0-11%) for the 5 drug metabolites. The comparison of biomarkers results to self-reports of abstinence identified 28% of all offenders as high risk and assigned them to more frequent testing and more intense monitoring. The longitudinal analysis shows that 56% (completers) of participants completed the program successfully and the remaining 44% (noncompliant) terminated prematurely. Two thirds (68%) of the completers were able to reduce or control their drinking and one third relapsed at least one time

  11. Maternal overreactive sympathetic nervous system responses to repeated infant crying predicts risk for impulsive harsh discipline of infants.

    Science.gov (United States)

    Joosen, Katharina J; Mesman, Judi; Bakermans-Kranenburg, Marian J; van Ijzendoorn, Marinus H

    2013-11-01

    Physiological reactivity to repeated infant crying was examined as a predictor of risk for harsh discipline use with 12-month-olds in a longitudinal study with 48 low-income mother-infant dyads. Physiological reactivity was measured while mothers listened to three blocks of infant cry sounds in a standard cry paradigm when their infants were 3 months old. Signs of harsh discipline use were observed during two tasks during a home visit when the infants were 12 months old. Mothers showing signs of harsh discipline (n = 10) with their 12-month-olds were compared to mothers who did not (n = 38) on their sympathetic (skin conductance levels [SCL]) and parasympathetic (respiratory sinus arrhythmia) reactivity to the cry sounds. Results showed a significant interaction effect for sympathetic reactivity only. Mean SCL of harsh-risk mothers showed a significant different response pattern from baseline to crying and onward into the recovery, suggesting that mean SCL of mothers who showed signs of harsh discipline continued to rise across the repeated bouts of cry sounds while, after an initial increase, mean SCL level of the other mothers showed a steady decline. We suggest that harsh parenting is reflected in physiological overreactivity to negative infant signals and discuss our findings from a polyvagal perspective.

  12. Program reference schedule baseline

    International Nuclear Information System (INIS)

    1986-07-01

    This Program Reference Schedule Baseline (PRSB) provides the baseline Program-level milestones and associated schedules for the Civilian Radioactive Waste Management Program. It integrates all Program-level schedule-related activities. This schedule baseline will be used by the Director, Office of Civilian Radioactive Waste Management (OCRWM), and his staff to monitor compliance with Program objectives. Chapter 1 includes brief discussions concerning the relationship of the PRSB to the Program Reference Cost Baseline (PRCB), the Mission Plan, the Project Decision Schedule, the Total System Life Cycle Cost report, the Program Management Information System report, the Program Milestone Review, annual budget preparation, and system element plans. Chapter 2 includes the identification of all Level 0, or Program-level, milestones, while Chapter 3 presents and discusses the critical path schedules that correspond to those Level 0 milestones

  13. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices

    Directory of Open Access Journals (Sweden)

    Rohit Shetty

    2017-01-01

    Full Text Available Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL haze on the measurement and repeatability of pachymetry and mean keratometry (Km of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL underwent imaging with a scanning slit imaging device (Orbscan II and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei. Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05 significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively. Km values were affected by haze when measured with the Pentacam HR (P < 0.05. The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively, Km values (P = 0.4 and 0.6, respectively, repeatability of TCT (P = 0.1 in both zones, and Km (P = 0.5 and 0.1, respectively with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution.

  14. Reliable intraocular pressure measurement using automated radio-wave telemetry.

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.

  15. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results. PMID:24531415

  16. A publication database for optical long baseline interferometry

    Science.gov (United States)

    Malbet, Fabien; Mella, Guillaume; Lawson, Peter; Taillifet, Esther; Lafrasse, Sylvain

    2010-07-01

    Optical long baseline interferometry is a technique that has generated almost 850 refereed papers to date. The targets span a large variety of objects from planetary systems to extragalactic studies and all branches of stellar physics. We have created a database hosted by the JMMC and connected to the Optical Long Baseline Interferometry Newsletter (OLBIN) web site using MySQL and a collection of XML or PHP scripts in order to store and classify these publications. Each entry is defined by its ADS bibcode, includes basic ADS informations and metadata. The metadata are specified by tags sorted in categories: interferometric facilities, instrumentation, wavelength of operation, spectral resolution, type of measurement, target type, and paper category, for example. The whole OLBIN publication list has been processed and we present how the database is organized and can be accessed. We use this tool to generate statistical plots of interest for the community in optical long baseline interferometry.

  17. Repeated Sleep Restriction in Adolescent Rats Altered Sleep Patterns and Impaired Spatial Learning/Memory Ability

    Science.gov (United States)

    Yang, Su-Rong; Sun, Hui; Huang, Zhi-Li; Yao, Ming-Hui; Qu, Wei-Min

    2012-01-01

    Study Objectives: To investigate possible differences in the effect of repeated sleep restriction (RSR) during adolescence and adulthood on sleep homeostasis and spatial learning and memory ability. Design: The authors examined electroencephalograms of rats as they were subjected to 4-h daily sleep deprivation that continued for 7 consecutive days and assessed the spatial learning and memory by Morris water maze test (WMT). Participants: Adolescent and adult rats. Measurements and Results: Adolescent rats exhibited a similar amount of rapid eye movement (REM) and nonrapid eye movement (NREM) sleep with higher slow wave activity (SWA, 0.5-4 Hz) and fewer episodes and conversions with prolonged durations, indicating they have better sleep quality than adult rats. After RSR, adult rats showed strong rebound of REM sleep by 31% on sleep deprivation day 1; this value was 37% on sleep deprivation day 7 in adolescents compared with 20-h baseline level. On sleep deprivation day 7, SWA in adult and adolescent rats increased by 47% and 33%, and such elevation lasted for 5 h and 7 h, respectively. Furthermore, the authors investigated the effects of 4-h daily sleep deprivation immediately after the water maze training sessions on spatial cognitive performance. Adolescent rats sleep-restricted for 7 days traveled a longer distance to find the hidden platform during the acquisition training and had fewer numbers of platform crossings in the probe trial than those in the control group, something that did not occur in the sleep-deprived adult rats. Conclusions: Repeated sleep restriction (RSR) altered sleep profiles and mildly impaired spatial learning and memory capability in adolescent rats. Citation: Yang SR; Sun H; Huang ZL; Yao MH; Qu WM. Repeated sleep restriction in adolescent rats altered sleep patterns and impaired spatial learning/memory ability. SLEEP 2012;35(6):849-859. PMID:22654204

  18. Safety of multiple repeated cycles of {sup 177}Lu-octreotate in patients with recurrent neuroendocrine tumour

    Energy Technology Data Exchange (ETDEWEB)

    Yordanova, Anna; Essler, Markus; Ahmadzadehfar, Hojjat [University Hospital Bonn, Department of Nuclear Medicine, Bonn (Germany); Mayer, Karin; Brossart, Peter [University Hospital Bonn, Department of Internal Medicine 3, Bonn (Germany); Gonzalez-Carmona, Maria A.; Strassburg, Christian P. [University Hospital Bonn, Department of Internal Medicine 1, Bonn (Germany)

    2017-07-15

    Peptide receptor radionuclide therapy (PRRT) is an effective therapy in patients with a somatostatin receptor-positive neuroendocrine tumour (NET). Still unclear is how many cycles of {sup 177}Lu-octreotate can be repeated while maintaining an acceptable toxicity profile. The purpose of this study was to assess the safety of repeated PRRT in patients with recurrent NET. We retrospectively evaluated data from 15 patients treated with repeated PRRT between 2004 and 2015. The median administered activity was 63.8 GBq (range 52-96.6 GBq) in a median of 9 cycles (range 8-13 cycles). Nonhaematological and haematological toxicities were assessed from clinical reports and laboratory data. The rates of adverse events in three therapy groups were compared: during cycles 1 to 4, cycles 5 to 8, and cycles 9 to 13. Baseline laboratory assessments were also compared with data obtained at the end of treatment. The overall survival in the study patients was compared with survival data in patients who received only a baseline PRRT of three or four cycles. We observed no life-threatening adverse events (CTC-4) during {sup 177}Lu-octreotate treatment. Reversible haematological toxicity (CTC-3) occurred in two patients (13%). No CTC-3/4 nephrotoxicity was recorded. More CTC-3 adverse events were recorded in the first therapy group than in the other two groups. Furthermore, there were no significant changes in the mean values of thrombocytes, leucocytes and serum creatinine before and after therapy. However, the mean haemoglobin levels fell from 14 g/dL to 11 g/dL. Finally, compared with those patients who received three or four cycles, there was a survival benefit in patients treated with repeated PRRT (censored overall survival 85.6 vs. 69.7 months, p < 0.001). Therapy with eight or more cycles of {sup 177}Lu-octreotate was well tolerated and led to a survival benefit in patients with recurrent NET. (orig.)

  19. CryoSat SAR/SARin Level1b products: assessment of BaselineC and improvements towards BaselineD

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Bouffard, Jerome; Parrinello, Tommaso

    2017-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvements in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. The current IPF, Baseline C, was released in operation in April 2015 and the second CryoSat reprocessing campaign was jointly initiated, taking benefit of the upgrade implemented in the IPF1 processing chain but also of some specific configurations for the calibration corrections. In particular, the CryoSat Level1b BaselineC products generated in the framework of the second reprocessing campaign include refined information for what concerns the mispointing angles and the calibration corrections. This poster will thus detail thus the evolutions that are currently planned for the CryoSat BaselineD SAR/SARin Level1b products and the corresponding quality improvements that are expected.

  20. Association of heme oxygenase-1 GT-repeat polymorphism with blood pressure phenotypes and its relevance to future cardiovascular mortality risk: an observation based on arsenic-exposed individuals.

    Science.gov (United States)

    Wu, Meei-Maan; Chiou, Hung-Yi; Chen, Chi-Ling; Hsu, Ling-I; Lien, Li-Ming; Wang, Chih-Hao; Hsieh, Yi-Chen; Wang, Yuan-Hung; Hsueh, Yu-Mei; Lee, Te-Chang; Cheng, Wen-Fang; Chen, Chien-Jen

    2011-12-01

    Heme oxygenase (HO)-1 is up-regulated as a cellular defense responding to stressful stimuli in experimental studies. A GT-repeat length polymorphism in the HO-1 gene promoter was inversely correlated to HO-1 induction. Here, we reported the association of GT-repeat polymorphism with blood pressure (BP) phenotypes, and their interaction on cardiovascular (CV) mortality risk in arsenic-exposed cohorts. Associations of GT-repeat polymorphism with BP phenotypes were investigated at baseline in a cross-sectional design. Effect of GT-repeat polymorphism on CV mortality was investigated in a longitudinal design stratified by hypertension. GT-repeat variants were grouped by S (accounting for CV covariates. Totally, 894 participants were recruited and analyzed. At baseline, carriers with HO-1 S alleles had lower diastolic BP (L/S genotypes, P = 0.014) and a lower possibility of being hypertensive (L/S genotypes, P = 0.048). After follow-up, HO-1 S allele was significantly associated with a reduced CV risk in hypertensive participants [relative mortality ratio (RMR) 0.27 (CI 0.11, 0.69), P = 0.007] but not in normotensive. Hypertensive participants without carrying the S allele had a 5.23-fold increased risk [RMR 5.23 (CI 1.99, 13.69), P = 0.0008] of CV mortality compared with normotensive carrying the S alleles. HO-1 short GT-repeat polymorphism may play a protective role in BP regulation and CV mortality risk in hypertensive individuals against environmental stressors. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Repeatability of pachymetric mapping using fourier domain optical coherence tomography in corneas with opacities.

    Science.gov (United States)

    Samy El Gendy, Nehal M; Li, Yan; Zhang, Xinbo; Huang, David

    2012-04-01

    To evaluate the repeatability of Fourier domain optical coherence tomography (OCT) pachymetric mapping in patients with corneal opacities and to assess the reliability of Fourier domain OCT with 830 nm wavelength as a pachymetric measurement tool in opaque corneas. A Fourier domain OCT system was used to map the corneal thickness of patients with corneal scars or dystrophy. A retrospective study of a consecutive series was conducted. The repeatability was measured using pooled standard deviation of repeated measurements. A slit-scanning tomography device provided pachymetric mapping for comparison. Seventeen eyes of 12 patients with corneal scars (7 trauma and 3 post infection) or dystrophy (2 Reis-Bucklers and 5 granular dystrophy) were included. The posterior corneal boundary was detectable in all cases. The average corneal thickness measured by OCT was 536 ± 89 μm in central 2 mm area, 553 ± 76 μm in pericentral 2- to 5-mm area, and 508 ± 93 μm for the minimum corneal thickness. The slit-scanning tomography central corneal thickness, 433 ± 111 μm, was significantly lower than OCT readings (mean difference -91.1 ± 33.3 μm, P = 0.002). Repeatability of the OCT measurements was 2.1 μm centrally and 1.2 μm pericentrally. Pachymetric mapping with Fourier domain OCT was highly repeatable. Fourier domain OCT is a reliable pachymetric tool in opaque corneas. In comparison, corneal thickness measured by the slit-scanning tomography is significantly thinner than those measured by the Fourier domain OCT in the presence of corneal opacities.

  2. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  3. Comparing Young and Elderly Serial Reaction Time Task Performance on Repeated and Random Conditions

    Directory of Open Access Journals (Sweden)

    Fatemeh Ehsani

    2012-07-01

    Full Text Available Objectives: Acquisition motor skill training in elderly is at great importance. The main purpose of this study was to compare young and elderly performance in serial reaction time task on different repeated and random conditions. Methods & Materials: A serial reaction time task by using software was applied for studying motor learning in 30 young and 30 elderly. Each group divided randomly implicitly and explicitly into subgroups. A task 4 squares with different colors appeared on the monitor and subjects were asked to press its defined key immediately after observing it. Subjects practiced 8 motor blocks (4 repeated blocks, then 2 random blocks and 2 repeated blocks. Block time that was dependent variable measured and Independent-samples t- test with repeated ANOVA measures were used in this test. Results: young groups performed both repeated and random sequences significantly faster than elderly (P0.05. Explicit older subgroup performed 7,8 blocks slower than 6 block with a significant difference (P<0.05. Conclusion: Young adults discriminate high level performance than elderly in both repeated and random practice. Elderly performed random practice better than repeated practice.

  4. Repeatability of measures of inflammatory cell number in bronchial biopsies in atopic asthma

    NARCIS (Netherlands)

    Sont, J. K.; Willems, L. N.; Evertse, C. E.; Hooijer, R.; Sterk, P. J.; van Krieken, J. H.

    1997-01-01

    Airway pathology is increasingly considered to be a major outcome in asthma research. The aim of this study was to examine the intra-observer, within-section and between-biopsy repeatability, together with the implications for statistical power of a computerized quantitative analysis of inflammatory

  5. The leucine-rich repeat structure.

    Science.gov (United States)

    Bella, J; Hindle, K L; McEwan, P A; Lovell, S C

    2008-08-01

    The leucine-rich repeat is a widespread structural motif of 20-30 amino acids with a characteristic repetitive sequence pattern rich in leucines. Leucine-rich repeat domains are built from tandems of two or more repeats and form curved solenoid structures that are particularly suitable for protein-protein interactions. Thousands of protein sequences containing leucine-rich repeats have been identified by automatic annotation methods. Three-dimensional structures of leucine-rich repeat domains determined to date reveal a degree of structural variability that translates into the considerable functional versatility of this protein superfamily. As the essential structural principles become well established, the leucine-rich repeat architecture is emerging as an attractive framework for structural prediction and protein engineering. This review presents an update of the current understanding of leucine-rich repeat structure at the primary, secondary, tertiary and quaternary levels and discusses specific examples from recently determined three-dimensional structures.

  6. Repeatability and consistency of individual behaviour in juvenile and adult Eurasian harvest mice

    Science.gov (United States)

    Schuster, Andrea C.; Carl, Teresa; Foerster, Katharina

    2017-04-01

    Knowledge on animal personality has provided new insights into evolutionary biology and animal ecology, as behavioural types have been shown to affect fitness. Animal personality is characterized by repeatable and consistent between-individual behavioural differences throughout time and across different situations. Behavioural repeatability within life history stages and consistency between life history stages should be checked for the independence of sex and age, as recent data have shown that males and females in some species may differ in the repeatability of behavioural traits, as well as in their consistency. We measured the repeatability and consistency of three behavioural and one cognitive traits in juvenile and adult Eurasian harvest mice ( Micromys minutus). We found that exploration, activity and boldness were repeatable in juveniles and adults. Spatial recognition measured in a Y Maze was only repeatable in adult mice. Exploration, activity and boldness were consistent before and after maturation, as well as before and after first sexual contact. Data on spatial recognition provided little evidence for consistency. Further, we found some evidence for a litter effect on behaviours by comparing different linear mixed models. We concluded that harvest mice express animal personality traits as behaviours were repeatable across sexes and consistent across life history stages. The tested cognitive trait showed low repeatability and was less consistent across life history stages. Given the rising interest in individual variation in cognitive performance, and in its relationship to animal personality, we suggest that it is important to gather more data on the repeatability and consistency of cognitive traits.

  7. Repeatability of the Oxford Foot Model in children with foot deformity.

    Science.gov (United States)

    McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim

    2018-03-01

    The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in pathological conditions. The aim of the study was to assess the repeatability of the OFM in children with foot deformity. Intra-tester repeatability was assessed for 45 children (15 typically developing, 15 hemiplegic, 15 clubfoot). Inter-tester repeatability was assessed in the clubfoot population. The mean absolute differences between testers (clubfoot) and sessions (clubfoot and hemiplegic) were calculated for each of 15 clinically relevant, kinematic variables and compared to typically developing children. Children with clubfoot showed a mean difference between visits of 2.9° and a mean difference between raters of 3.6° Mean absolute differences were within one degree for the intra and inter-rater reliability in 12/15 variables. Hindfoot rotation, forefoot/tibia abduction and forefoot supination were the most variable between testers. Overall the clubfoot data were less variable than the typically developing population. Children with hemiplegia demonstrated slightly higher differences between sessions (mean 4.1°), with the most reliable data in the sagittal plane, and largest differences in the transverse plane. The OFM was designed to measure different types of foot deformity. The results of this study show that it provides repeatable results in children with foot deformity. To be distinguished from measurement artifact, changes in foot kinematics as a result of intervention or natural progression over time must be greater than the repeatability reported here. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    Science.gov (United States)

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  10. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK

    Directory of Open Access Journals (Sweden)

    Rosa Weiss Telles

    Full Text Available Abstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK. Material and methods: A test–retest design including 19 adults (38 knee images was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD values. Repeatability was assessed for IMD and joint space width (JSW measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively. Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV = 54.68%; intraclass correlation coefficient (ICC (95%CI = 0.59 (0.34–0.77]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI = 0.74 (0.55–0.85–0.94 (0.87–0.97]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK.

  11. A Lack of Systemic Absorption Following the Repeated Application of Topical Quetiapine in Healthy Adults.

    Science.gov (United States)

    Kayhart, Bryce; Lapid, Maria I; Nelson, Sarah; Cunningham, Julie L; Thompson, Virginia H; Leung, Jonathan G

    2018-01-01

    In the absence of suitable oral or intravenous access for medication administration and when the intramuscular medications are undesirable, alternative routes for drug delivery may be considered. Antipsychotics administered via an inhaled, intranasal, rectal, or topical route have been described in the literature. Topically administered antipsychotics have been previously reported to produce negligible systemic absorption despite being used in clinical practice for nausea and behavioral symptoms associated with dementia. Additionally, the American Academy of Hospice and Palliative Medicine recommends against the use of topical medications that lack supporting literature. Three studies have assessed the systemic absorption of different antipsychotics after administration of only a single, topically applied dose. To evaluate whether the repeated administration of a topically applied antipsychotic may result in detectable serum levels in an accumulating fashion, a pharmacokinetic study was conducted. Five healthy, adult participants consented to receive extemporaneously prepared topical quetiapine in Lipoderm every 4 hours for a total of 5 doses. Blood samples were drawn at baseline and hours 2, 4, 8, 12, 16, and 24, and serum quetiapine concentrations were measured using high-performance liquid chromatography. Quetiapine was undetectable in every sample from 3 participants. Two participants had minimally detectable serum quetiapine levels no sooner than hour 12 of the study period. Extemporaneously prepared quetiapine in Lipoderm resulted in nonexistent or minimal serum level following repeated topical administration. The use of topically applied quetiapine should still be questioned.

  12. Prognostic usefulness of repeated echocardiographic evaluation after acute myocardial infarction. TRACE Study Group. TRAndolapril Cardiac Evaluation

    DEFF Research Database (Denmark)

    Korup, E; Køber, L; Torp-Pedersen, C

    1999-01-01

    The prognostic value of repeated echocardiographic measurement of left ventricular function after acute myocardial infarction was evaluated. We found that repeated measurements of wall motion index in survivors of acute myocardial infarction, with no reinfarction, provide important prognostic...

  13. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  14. The relationship between psychological distress and baseline sports-related concussion testing.

    Science.gov (United States)

    Bailey, Christopher M; Samples, Hillary L; Broshek, Donna K; Freeman, Jason R; Barth, Jeffrey T

    2010-07-01

    This study examined the effect of psychological distress on neurocognitive performance measured during baseline concussion testing. Archival data were utilized to examine correlations between personality testing and computerized baseline concussion testing. Significantly correlated personality measures were entered into linear regression analyses, predicting baseline concussion testing performance. Suicidal ideation was examined categorically. Athletes underwent testing and screening at a university athletic training facility. Participants included 47 collegiate football players 17 to 19 years old, the majority of whom were in their first year of college. Participants were administered the Concussion Resolution Index (CRI), an internet-based neurocognitive test designed to monitor and manage both at-risk and concussed athletes. Participants took the Personality Assessment Inventory (PAI), a self-administered inventory designed to measure clinical syndromes, treatment considerations, and interpersonal style. Scales and subscales from the PAI were utilized to determine the influence psychological distress had on the CRI indices: simple reaction time, complex reaction time, and processing speed. Analyses revealed several significant correlations among aspects of somatic concern, depression, anxiety, substance abuse, and suicidal ideation and CRI performance, each with at least a moderate effect. When entered into a linear regression, the block of combined psychological symptoms accounted for a significant amount of baseline CRI performance, with moderate to large effects (r = 0.23-0.30). When examined categorically, participants with suicidal ideation showed significantly slower simple reaction time and complex reaction time, with a similar trend on processing speed. Given the possibility of obscured concussion deficits after injury, implications for premature return to play, and the need to target psychological distress outright, these findings heighten the clinical

  15. Assessment of What/For What? Teachers' and Head Teachers' Views on Using Well-Being and Involvement as a Screening Measure for Conducting Baseline Assessment on School Entry in English Primary Schools

    Science.gov (United States)

    Guimaraes, Sofia; Howe, Sally; Clausen, Sigrid Brogaard; Cottle, Michelle

    2016-01-01

    Baseline assessment has recently been trialled as part of an accountability measure in English primary schools. The research presented in this colloquium examines the views of teachers related to using well-being and involvement indicators as a starting point for baseline assessment. The findings suggest that the focus on well-being was welcomed…

  16. DairyBISS Baseline report

    NARCIS (Netherlands)

    Buizer, N.N.; Berhanu, Tinsae; Murutse, Girmay; Vugt, van S.M.

    2015-01-01

    This baseline report of the Dairy Business Information Service and Support (DairyBISS) project presents the findings of a baseline survey among 103 commercial farms and 31 firms and advisors working in the dairy value chain. Additional results from the survey among commercial dairy farms are

  17. Repeatability of quantitative 18F-FLT uptake measurements in solid tumors: an individual patient data multi-center meta-analysis.

    Science.gov (United States)

    Kramer, G M; Liu, Y; de Langen, A J; Jansma, E P; Trigonis, I; Asselin, M-C; Jackson, A; Kenny, L; Aboagye, E O; Hoekstra, O S; Boellaard, R

    2018-06-01

    3'-deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative 18 F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of 18 F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five 18 F-FLT repeatability cohorts in solid tumors. 18 F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUV max , SUV mean , SUV peak , proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all 18 F-FLT uptake metrics (R 2  ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUV peak (RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUV max  ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. In multi-center studies

  18. Repeated episodes of chronic intermittent ethanol promote insensitivity to devaluation of the reinforcing effect of ethanol.

    Science.gov (United States)

    Lopez, M F; Becker, H C; Chandler, L J

    2014-11-01

    Studies in animal models have shown that repeated episodes of alcohol dependence and withdrawal promote escalation of drinking that is presumably associated with alterations in the addiction neurocircuitry. Using a lithium chloride-ethanol pairing procedure to devalue the reinforcing properties of ethanol, the present study determined whether multiple cycles of chronic intermittent ethanol (CIE) exposure by vapor inhalation also alters the sensitivity of drinking behavior to the devaluation of ethanol's reinforcing effects. The effect of devaluation on operant ethanol self-administration and extinction was examined in mice prior to initiation of CIE (short drinking history) and after repeated cycles of CIE or air control exposure (long drinking history). Devaluation significantly attenuated the recovery of baseline ethanol self-administration when tested either prior to CIE or in the air-exposed controls that had experienced repeated bouts of drinking but no CIE. In contrast, in mice that had undergone repeated cycles of CIE exposure that promoted escalation of ethanol drinking, self-administration was completely resistant to the effect of devaluation. Devaluation had no effect on the time course of extinction training in either pre-CIE or post-CIE mice. Taken together, these results are consistent with the suggestion that repeated cycles of ethanol dependence and withdrawal produce escalation of ethanol self-administration that is associated with a change in sensitivity to devaluation of the reinforcing properties of ethanol. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. The effects of toluene plus noise on hearing thresholds: an evaluation based on repeated measurements in the German printing industry.

    Science.gov (United States)

    Schäper, Michael; Seeber, Andreas; van Thriel, Christoph

    2008-01-01

    The ototoxicity of occupational exposure to toluene plus noise was investigated in a longitudinal study in rotogravure printing and existing findings in the literature were evaluated. The study comprised four repeated examinations during 5 years and started with 333 male workers. Lifetime weighted average exposures (LWAE) to toluene and noise were determined from individual work histories and historic recordings; recent individual exposures were measured 10 times during the study (toluene, active sampling; noise, stationary measurements). Auditory thresholds were measured with pure tone audiometry at 0.125, 0.25, 0.5, 0.75, 1, 2, 3, 4, 6, 8, 12 kHz. Mean LWAE exposures to toluene and noise were 45+/-17 ppm plus 82+/-7 dB(A) for high toluene exposed and 10+/-7 ppm plus 82+/-4 dB(A) for low toluene exposed subjects, mean current exposures were 26+/-20 ppm plus 81+/-4 dB(A) and 3+/-3 ppm plus 82+/-4 dB(A). Mean exposure duration was 21.3+/-6.5 years for long exposed and 5.9+/-2.2 years for short exposed subjects. Repeated measurement analyses of variance did not reveal effects of toluene intensity, exposure duration and interactions between toluene intensity and noise intensity. Noise intensity [79+/-3 dB(A) vs. 84+/-1 dB(A)] was significant for auditory thresholds. A case concept utilising developments of individual auditory thresholds did not reveal significant toluene effects. Logistic models including age, exposure duration, toluene in ambient air, current noise and either hippuric acid or ortho-cresol (o-cresol) found only age to be significant for elevated OR of high frequency hearing loss. Due to missing toluene effects, it was concluded that the threshold level for developing hearing loss as a result of occupational exposure to toluene plus noise might be above the current limit of 50 ppm toluene.

  20. Baseline rationing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    The standard problem of adjudicating conflicting claims describes a situation in which a given amount of a divisible good has to be allocated among agents who hold claims against it exceeding the available amount. This paper considers more general rationing problems in which, in addition to claims...... to international protocols for the reduction of greenhouse emissions, or water distribution in drought periods. We define a family of allocation methods for such general rationing problems - called baseline rationing rules - and provide an axiomatic characterization for it. Any baseline rationing rule within...... the family is associated with a standard rule and we show that if the latter obeys some properties reflecting principles of impartiality, priority and solidarity, the former obeys them too....

  1. Spatial Cluster Detection for Repeatedly Measured Outcomes while Accounting for Residential History

    OpenAIRE

    Cook, Andrea J.; Gold, Diane R.; Li, Yi

    2009-01-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information ...

  2. Validity and repeatability of goniometry in normal horses.

    Science.gov (United States)

    Adair, Henry S; Marcellin-Little, Denis J; Levine, David

    2016-07-19

    To assess validity and inter- and intra-tester reliability of equine goniometry and to establish values for carpal, metacarpophalangeal, tarsal, and metatarsophalangeal flexion and extension in horses. Seventeen healthy equine subjects of varied breeds were used. Three investigators blindly and independently measured in triplicate the extension and flexion of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints of 17 horses after sedation. Radiographs of these joints in flexion and extension were acquired while under sedation. Goniometric and radiographic measurements were compared statistically and were correlated. A Bland-Altman plot was constructed. Inter- and intra-tester repeatability of goniometry were evaluated by calculating intraclass correlation coefficients (ICC). Mean flexion and extension of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints were calculated. Goniometric and radiographic measurements did not differ statistically and were significantly correlated (correlation coefficients ranged from 0.59 - 0.89). The mean difference between goniometric and radiographic measurements was 0.4°. Triplicate measurements collected by the three raters did not differ significantly within raters (ICC ranging from 0.950 - 0.995) and between raters (ICC ranging from 0.942 - 0.989). Goniometry is a valid and repeatable tool for evaluation of the range of motion of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints in standing, sedated healthy horses.

  3. Blood pressure control in hypertensive pediatric renal transplants: role of repeated ABPM following transplantation.

    Science.gov (United States)

    Krmar, Rafael T; Berg, Ulla B

    2008-10-01

    Hypertension in pediatric renal transplants is a widespread condition associated with high mortality risk in early adult life. Ambulatory blood pressure monitoring (ABPM) was found to be superior to office blood pressure (BP) in identifying true hypertensive and responders to treatment. The aim of this study was to investigate the role of repeated ABPM, performed at yearly intervals following transplantation, in the assessment and decision-making processes of post-transplant hypertension. Thirty-seven recipients (23 males; aged 10.5 +/- 4.3 years) who were followed for 4.3 +/- 2.2 years (range 2-9) after transplantation were eligible for analysis. The mean follow-up time between the baseline (1 year post-transplantation) and the most recent ABPM examination was 3.3 +/- 2.2 years (range 1-8). Throughout the follow-up period, antihypertensive therapy was either started or intensified in 27 recipients. These interventions were decided based on ABPM results obtained on 40 of 44 occasions. At last follow-up, 24 of 29 treated hypertensive recipients displayed controlled BP. This figure was significantly higher compared to our historical hypertensive control recipients in whom ABPM was applied for the first time in treatment at 6 +/- 3.3 years (range 2-15) after transplantation, while therapeutic decisions were driven by office BP measurements (95 % confidence interval (95% CI) for the difference between proportions (80.6-32 %) 36-60 %, P = 0.001). Our study shows that, in a population with high risk for hypertension, repeated ABPM may significantly help to improve BP control.

  4. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction...... and measured on a COBAS Mira autoanalyser from Roche. The main findings were that samples for analysis of creatinine should be kept at a temperature of -20 degrees C or lower and frozen and thawed only once. The limit of detection, determined as 3 x SD of 20 determinations of a sample at a low concentration (6...

  5. TAPIR--Finnish national geochemical baseline database.

    Science.gov (United States)

    Jarva, Jaana; Tarvainen, Timo; Reinikainen, Jussi; Eklund, Mikael

    2010-09-15

    In Finland, a Government Decree on the Assessment of Soil Contamination and Remediation Needs has generated a need for reliable and readily accessible data on geochemical baseline concentrations in Finnish soils. According to the Decree, baseline concentrations, referring both to the natural geological background concentrations and the diffuse anthropogenic input of substances, shall be taken into account in the soil contamination assessment process. This baseline information is provided in a national geochemical baseline database, TAPIR, that is publicly available via the Internet. Geochemical provinces with elevated baseline concentrations were delineated to provide regional geochemical baseline values. The nationwide geochemical datasets were used to divide Finland into geochemical provinces. Several metals (Co, Cr, Cu, Ni, V, and Zn) showed anomalous concentrations in seven regions that were defined as metal provinces. Arsenic did not follow a similar distribution to any other elements, and four arsenic provinces were separately determined. Nationwide geochemical datasets were not available for some other important elements such as Cd and Pb. Although these elements are included in the TAPIR system, their distribution does not necessarily follow the ones pre-defined for metal and arsenic provinces. Regional geochemical baseline values, presented as upper limit of geochemical variation within the region, can be used as trigger values to assess potential soil contamination. Baseline values have also been used to determine upper and lower guideline values that must be taken into account as a tool in basic risk assessment. If regional geochemical baseline values are available, the national guideline values prescribed in the Decree based on ecological risks can be modified accordingly. The national geochemical baseline database provides scientifically sound, easily accessible and generally accepted information on the baseline values, and it can be used in various

  6. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    Science.gov (United States)

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. The relationship, structure and profiles of schizophrenia measurements: a post-hoc analysis of the baseline measures from a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Chen Lei

    2011-12-01

    Full Text Available Background To fully assess the various dimensions affected by schizophrenia, clinical trials often include multiple scales measuring various symptom profiles, cognition, quality of life, subjective well-being, and functional impairment. In this exploratory study, we characterized the relationships among six clinical, functional, cognitive, and quality-of-life measures, identifying a parsimonious set of measurements. Methods We used baseline data from a randomized, multicenter study of patients diagnosed with schizophrenia, schizoaffective disorder, or schizophreniform disorder who were experiencing an acute symptom exacerbation (n = 628 to examine the relationship among several outcome measures. These measures included the Positive and Negative Syndrome Scale (PANSS, Montgomery-Asberg Depression Rating Scale (MADRS, Brief Assessment of Cognition in Schizophrenia Symbol Coding Test, Subjective Well-being Under Neuroleptics Scale Short Form (SWN-K, Schizophrenia Objective Functioning Instrument (SOFI, and Quality of Life Scale (QLS. Three analytic approaches were used: 1 path analysis; 2 factor analysis; and 3 categorical latent variable analysis. In the optimal path model, the SWN-K was selected as the final outcome, while the SOFI mediated the effect of the exogenous variables (PANSS, MADRS on the QLS. Results The overall model explained 47% of variance in QLS and 17% of the variance in SOFI, but only 15% in SWN-K. Factor analysis suggested four factors: "Functioning," "Daily Living," "Depression," and "Psychopathology." A strong positive correlation was observed between the SOFI and QLS (r = 0.669, and both the QLS and SOFI loaded on the "Functioning" factor, suggesting redundancy between these scales. The measurement profiles from the categorical latent variable analysis showed significant variation in functioning and quality of life despite similar levels of psychopathology. Conclusions Researchers should consider collecting PANSS, SOFI, and

  8. Addendum to the 2015 Eastern Interconnect Baselining and Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Follum, James D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    This report serves as an addendum to the report 2015 Eastern Interconnect Baselining and Analysis Report (Amidan, Follum, and Freeman, 2015). This addendum report investigates the following: the impact of shorter record lengths and of adding a daily regularization term to the date/time models for angle pair measurements, additional development of a method to monitor the trend in phase angle pairs, the effect of changing the length of time to determine a baseline, when calculating atypical events, and a comparison between quantitatively discovered atypical events and actual events.

  9. 78 FR 65594 - Vehicular Repeaters

    Science.gov (United States)

    2013-11-01

    ... coordinators estimate the effect on coordination fees? Does the supposed benefit that mobile repeater stations... allow the licensing and operation of vehicular repeater systems and other mobile repeaters by public... email: [email protected] or phone: 202-418- 0530 or TTY: 202-418-0432. For detailed instructions for...

  10. Tevatron serial data repeater system

    International Nuclear Information System (INIS)

    Ducar, R.J.

    1981-01-01

    A ten megabit per second serial data repeater system has been developed for the 6.28km Tevatron accelerator. The repeaters are positioned at each of the thirty service buildings and accommodate control and abort system communications as well as distribution of the Tevatron time and energy clocks. The repeaters are transparent to the particular protocol of the transmissions. Serial data are encoded locally as unipolar two volt signals employing the self-clocking Manchester Bi-Phase code. The repeaters modulate the local signals to low-power bursts of 50 MHz rf carrier for the 260m transmission between service buildings. The repeaters also demodulate the transmission and restructure the data for local utilization. The employment of frequency discrimination techniques yields high immunity to the characteristic noise spectrum

  11. Mass hierarchy sensitivity of medium baseline reactor neutrino experiments with multiple detectors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong-Xin, E-mail: hxwang@iphy.me [Department of Physics, Nanjing University, Nanjing 210093 (China); Zhan, Liang; Li, Yu-Feng; Cao, Guo-Fu [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, Shen-Jian [Department of Physics, Nanjing University, Nanjing 210093 (China)

    2017-05-15

    We report the neutrino mass hierarchy (MH) determination of medium baseline reactor neutrino experiments with multiple detectors, where the sensitivity of measuring the MH can be significantly improved by adding a near detector. Then the impact of the baseline and target mass of the near detector on the combined MH sensitivity has been studied thoroughly. The optimal selections of the baseline and target mass of the near detector are ∼12.5 km and ∼4 kton respectively for a far detector with the target mass of 20 kton and the baseline of 52.5 km. As typical examples of future medium baseline reactor neutrino experiments, the optimal location and target mass of the near detector are selected for the specific configurations of JUNO and RENO-50. Finally, we discuss distinct effects of the reactor antineutrino energy spectrum uncertainty for setups of a single detector and double detectors, which indicate that the spectrum uncertainty can be well constrained in the presence of the near detector.

  12. Dependence of optimum baseline setting on scatter fraction and detector response function

    International Nuclear Information System (INIS)

    Atkins, F.B.; Beck, R.N.; Hoffer, P.B.; Palmer, D.

    1977-01-01

    A theoretical and experimental investigation has been undertaken to determine the dependence of an optimum baseline setting on the amount of scattered radiation recorded in a spectrum, and on the energy resolution of the detector. In particular, baseline settings were established for clinical examinations which differed greatly in the amount of scattered radiation, namely, liver and brain scans, for which individual variations were found to produce only minimal fluctuations in the optimum baseline settings. This analysis resulted in an optimum baseline setting of 125.0 keV for brain scans and 127.2 keV for liver scans for the scintillation camera used in these studies. The criterion that was used is based on statistical considerations of the measurement of an unscattered component in the presence of a background due to scattered photons. The limitations of such a criterion are discussed, and phantom images are presented to illustrate these effects at various baseline settings. (author)

  13. Central adaptation to repeated galvanic vestibular stimulation: implications for pre-flight astronaut training.

    Directory of Open Access Journals (Sweden)

    Valentina Dilda

    Full Text Available Healthy subjects (N = 10 were exposed to 10-min cumulative pseudorandom bilateral bipolar Galvanic vestibular stimulation (GVS on a weekly basis for 12 weeks (120 min total exposure. During each trial subjects performed computerized dynamic posturography and eye movements were measured using digital video-oculography. Follow up tests were conducted 6 weeks and 6 months after the 12-week adaptation period. Postural performance was significantly impaired during GVS at first exposure, but recovered to baseline over a period of 7-8 weeks (70-80 min GVS exposure. This postural recovery was maintained 6 months after adaptation. In contrast, the roll vestibulo-ocular reflex response to GVS was not attenuated by repeated exposure. This suggests that GVS adaptation did not occur at the vestibular end-organs or involve changes in low-level (brainstem-mediated vestibulo-ocular or vestibulo-spinal reflexes. Faced with unreliable vestibular input, the cerebellum reweighted sensory input to emphasize veridical extra-vestibular information, such as somatosensation, vision and visceral stretch receptors, to regain postural function. After a period of recovery subjects exhibited dual adaption and the ability to rapidly switch between the perturbed (GVS and natural vestibular state for up to 6 months.

  14. Central adaptation to repeated galvanic vestibular stimulation: implications for pre-flight astronaut training.

    Science.gov (United States)

    Dilda, Valentina; Morris, Tiffany R; Yungher, Don A; MacDougall, Hamish G; Moore, Steven T

    2014-01-01

    Healthy subjects (N = 10) were exposed to 10-min cumulative pseudorandom bilateral bipolar Galvanic vestibular stimulation (GVS) on a weekly basis for 12 weeks (120 min total exposure). During each trial subjects performed computerized dynamic posturography and eye movements were measured using digital video-oculography. Follow up tests were conducted 6 weeks and 6 months after the 12-week adaptation period. Postural performance was significantly impaired during GVS at first exposure, but recovered to baseline over a period of 7-8 weeks (70-80 min GVS exposure). This postural recovery was maintained 6 months after adaptation. In contrast, the roll vestibulo-ocular reflex response to GVS was not attenuated by repeated exposure. This suggests that GVS adaptation did not occur at the vestibular end-organs or involve changes in low-level (brainstem-mediated) vestibulo-ocular or vestibulo-spinal reflexes. Faced with unreliable vestibular input, the cerebellum reweighted sensory input to emphasize veridical extra-vestibular information, such as somatosensation, vision and visceral stretch receptors, to regain postural function. After a period of recovery subjects exhibited dual adaption and the ability to rapidly switch between the perturbed (GVS) and natural vestibular state for up to 6 months.

  15. Repeat Customer Success in Extension

    Science.gov (United States)

    Bess, Melissa M.; Traub, Sarah M.

    2013-01-01

    Four multi-session research-based programs were offered by two Extension specialist in one rural Missouri county. Eleven participants who came to multiple Extension programs could be called "repeat customers." Based on the total number of participants for all four programs, 25% could be deemed as repeat customers. Repeat customers had…

  16. Film repeats in radiology department

    International Nuclear Information System (INIS)

    Suwan, A. Z.; Al-Shakharah, A. I

    1997-01-01

    During a one year period, 4910 radiographs of 55780 films were repeated. The objective of our study was to analyse and to classify the causes in order to minimize the repeats, cut the expenses and to provide optimal radiographs for accurate diagnosis. Analysis of the different factors revealed that, 43.6% of film repeats in our service were due to faults in exposure factors, centering comprises 15.9% of the repeats, while too much collimation was responsible for 7.6% of these repeats. All of which can be decreased by awareness and programmed training of technicians. Film blurring caused by patient motion was also responsible for 4.9% for radiographs reexamination, which can be minimized by detailed explanation to the patient and providing the necessary privacy. Fogging of X-Ray films by improper storage or inadequate handling or processing faults were responsible for 14.5% in repeats in our study. Methods and criteria for proper storage and handling of films were discussed. Recommendation for using modern day-light and laser processor has been high lighted. Artefacts are noticeably high in our cases, due to spinal dresses and frequent usage of precious metals for c osmotic purposes in this part of the world. The repeated films comprise 8.8% of all films We conclude that, the main factor responsible for repeats of up to 81.6% of cases was the technologists, thus emphasizing the importance of adequate training of the technologists. (authors). 15 refs., 9 figs., 1 table

  17. Repeated nicotine exposure enhances reward-related learning in the rat.

    Science.gov (United States)

    Olausson, Peter; Jentsch, J David; Taylor, Jane R

    2003-07-01

    Repeated exposure to addictive drugs causes neuroadaptive changes in cortico-limbic-striatal circuits that may underlie alterations in incentive-motivational processes and reward-related learning. Such drug-induced alterations may be relevant to drug addiction because enhanced incentive motivation and increased control over behavior by drug-associated stimuli may contribute to aspects of compulsive drug-seeking and drug-taking behaviors. This study investigated the consequences of repeated nicotine treatment on the acquisition and performance of Pavlovian discriminative approach behavior, a measure of reward-related learning, in male rats. Water-restricted rats were trained to associate a compound conditioned stimulus (tone+light) with the availability of water (the unconditioned stimulus) in 15 consecutive daily sessions. In separate experiments, rats were repeatedly treated with nicotine (0.35 mg/kg, s.c.) either (1) prior to the onset of training, (2) after each daily training session was completed (ie postsession injections), or (3) received nicotine both before the onset of training as well as after each daily training session. In this study, all nicotine treatment schedules increased Pavlovian discriminative approach behavior and, thus, prior repeated exposure to nicotine, repeated postsession nicotine injections, or both, facilitated reward-related learning.

  18. Repeat migration and disappointment.

    Science.gov (United States)

    Grant, E K; Vanderkamp, J

    1986-01-01

    This article investigates the determinants of repeat migration among the 44 regions of Canada, using information from a large micro-database which spans the period 1968 to 1971. The explanation of repeat migration probabilities is a difficult task, and this attempt is only partly successful. May of the explanatory variables are not significant, and the overall explanatory power of the equations is not high. In the area of personal characteristics, the variables related to age, sex, and marital status are generally significant and with expected signs. The distance variable has a strongly positive effect on onward move probabilities. Variables related to prior migration experience have an important impact that differs between return and onward probabilities. In particular, the occurrence of prior moves has a striking effect on the probability of onward migration. The variable representing disappointment, or relative success of the initial move, plays a significant role in explaining repeat migration probabilities. The disappointment variable represents the ratio of actural versus expected wage income in the year after the initial move, and its effect on both repeat migration probabilities is always negative and almost always highly significant. The repeat probabilities diminish after a year's stay in the destination region, but disappointment in the most recent year still has a bearing on the delayed repeat probabilities. While the quantitative impact of the disappointment variable is not large, it is difficult to draw comparisons since similar estimates are not available elsewhere.

  19. Knowledge and Skill Retention of In-Service versus Preservice Nursing Professionals following an Informal Training Program in Pediatric Cardiopulmonary Resuscitation: A Repeated-Measures Quasiexperimental Study

    Directory of Open Access Journals (Sweden)

    Jhuma Sankar

    2013-01-01

    Full Text Available Our objective was to compare the impact of a training program in pediatric cardiopulmonary resuscitation (CPR on the knowledge and skills of in-service and preservice nurses at prespecified time points. This repeated-measures quasiexperimental study was conducted in the pediatric emergency and ICU of a tertiary care teaching hospital between January and March 2011. We assessed the baseline knowledge and skills of nursing staff (in-service nurses and final year undergraduate nursing students (preservice nurses using a validated questionnaire and a skill checklist, respectively. The participants were then trained on pediatric CPR using standard guidelines. The knowledge and skills were reassessed immediately after training and at 6 weeks after training. A total of 74 participants—28 in-service and 46 preservice professionals—were enrolled. At initial assessment, in-service nurses were found to have insignificant higher mean knowledge scores (6.6 versus 5.8, P=0.08 while the preservice nurses had significantly higher skill scores (6.5 versus 3.2, P<0.001. Immediately after training, the scores improved in both groups. At 6 weeks however, we observed a nonuniform decline in performance in both groups—in-service nurses performing better in knowledge test (10.5 versus 9.1, P=0.01 and the preservice nurses performing better in skill test (9.8 versus 7.4, P<0.001. Thus, knowledge and skills of in-service and preservice nurses in pediatric CPR improved with training. In comparison to preservice nurses, the in-service nurses seemed to retain knowledge better with time than skills.

  20. Baseline Estimation and Outlier Identification for Halocarbons

    Science.gov (United States)

    Wang, D.; Schuck, T.; Engel, A.; Gallman, F.

    2017-12-01

    The aim of this paper is to build a baseline model for halocarbons and to statistically identify the outliers under specific conditions. In this paper, time series of regional CFC-11 and Chloromethane measurements was discussed, which taken over the last 4 years at two locations, including a monitoring station at northwest of Frankfurt am Main (Germany) and Mace Head station (Ireland). In addition to analyzing time series of CFC-11 and Chloromethane, more importantly, a statistical approach of outlier identification is also introduced in this paper in order to make a better estimation of baseline. A second-order polynomial plus harmonics are fitted to CFC-11 and chloromethane mixing ratios data. Measurements with large distance to the fitting curve are regard as outliers and flagged. Under specific requirement, the routine is iteratively adopted without the flagged measurements until no additional outliers are found. Both model fitting and the proposed outlier identification method are realized with the help of a programming language, Python. During the period, CFC-11 shows a gradual downward trend. And there is a slightly upward trend in the mixing ratios of Chloromethane. The concentration of chloromethane also has a strong seasonal variation, mostly due to the seasonal cycle of OH. The usage of this statistical method has a considerable effect on the results. This method efficiently identifies a series of outliers according to the standard deviation requirements. After removing the outliers, the fitting curves and trend estimates are more reliable.

  1. Quantum repeated games revisited

    International Nuclear Information System (INIS)

    Frąckiewicz, Piotr

    2012-01-01

    We present a scheme for playing quantum repeated 2 × 2 games based on Marinatto and Weber’s approach to quantum games. As a potential application, we study the twice repeated Prisoner’s Dilemma game. We show that results not available in the classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games proposed by Iqbal and Toor. We point out the drawbacks that make their results unacceptable. (paper)

  2. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim

    2013-01-01

    BACKGROUND: Understanding fluctuations in lifestyle indicators is important to identify relevant time periods to intervene in order to promote a healthy lifestyle; however, objective assessment of multiple lifestyle indicators has never been done using a repeated-measures design. The primary aim...... was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...... to missing data, 730 children were included in the current analytical sample. An accelerometer was worn for 7 days and 8 nights during autumn, winter and spring, from which physical activity, sedentary time and sleep duration were measured. Cardio-respiratory fitness was assessed using a 10-min intermittent...

  3. The Effects of Caffeine, Taurine, or Caffeine-Taurine Coingestion on Repeat-Sprint Cycling Performance and Physiological Responses.

    Science.gov (United States)

    Warnock, Rory; Jeffries, Owen; Patterson, Stephen; Waldron, Mark

    2017-11-01

    To investigate the effects of caffeine (C), taurine (T), caffeine and taurine coingestion (C +T), or placebo (P) on repeated Wingate cycling performance and associated physiological responses. Seven male team-sport players participated in a randomized, single-blind, crossover study, where they completed 3 Wingate tests, each separated by 2 min, an hour after ingesting: C (5 mg/kg body mass [BM]), T (50 mg/kg BM), C +T (5 mg/kg BM + 50 mg/kg BM), or P (5 mg/kg BM) in a gelatin capsule. Performance was measured on an ergometer, and blood lactate, perceived exertion, heart rate (HR), mean arterial pressure (MAP), and rate pressure product (RPP) were measured at rest (presupplement), baseline (1 h postsupplement), and during and after exercise. Magnitude-based inferences revealed that all of the supplements increased (small to moderate, likely to very likely) mean peak power (MPP), peak power (PP), and mean power (MP) compared to P, with greater MPP, PP, and MP in T compared to C (small, possible). Intrasprint fatigue index (%FI Intra ) was greater in T compared to P and C (moderate, likely), and %FI Inter was lower in T compared to C (small, possible). C and C +T increased HR, MAP, and RPP compared to P and T at baseline (moderate to very large, likely to most likely); however, these only remained higher in C compared to all conditions in the final sprint. T elicited greater improvements in performance compared to P, C, or C +T while reducing the typical chronotropic and pressor effects of C.

  4. [Establishing IAQ Metrics and Baseline Measures.] "Indoor Air Quality Tools for Schools" Update #20

    Science.gov (United States)

    US Environmental Protection Agency, 2009

    2009-01-01

    This issue of "Indoor Air Quality Tools for Schools" Update ("IAQ TfS" Update) contains the following items: (1) News and Events; (2) IAQ Profile: Establishing Your Baseline for Long-Term Success (Feature Article); (3) Insight into Excellence: Belleville Township High School District #201, 2009 Leadership Award Winner; and (4) Have Your Questions…

  5. Is CP violation observable in long baseline neutrino oscillation experiments?

    International Nuclear Information System (INIS)

    Tanimoto, M.

    1997-01-01

    We have studied CP violation originating from the phase of the neutrino-mixing matrix in the long baseline neutrino oscillation experiments. The direct measurement of CP violation is the difference of the transition probabilities between CP-conjugate channels. In those experiments, the CP-violating effect is not suppressed if the highest neutrino mass scale is taken to be 1 endash 5 eV, which is appropriate for the cosmological hot dark matter. Assuming the hierarchy for the neutrino masses, the upper bounds of CP violation have been calculated for three cases, in which mixings are constrained by the recent short baseline ones. The calculated upper bounds are larger than 10 -2 , which will be observable in the long baseline accelerator experiments. The matter effect, which is not CP invariant, has been also estimated in those experiments. copyright 1997 The American Physical Society

  6. Office of Civilian Radioactive Waste Management Program Cost and Schedule Baseline

    International Nuclear Information System (INIS)

    1992-09-01

    The purpose of this document is to establish quantitative expressions of proposed costs and schedule to serve as a basis for measurement of program performance. It identifies the components of the Program Cost and Schedule Baseline (PCSB) that will be subject to change control by the Executive (Level 0) and Program (Level 1) Change Control Boards (CCBS) and establishes their baseline values. This document also details PCSB reporting, monitoring, and corrective action requirements. The Program technical baseline contained in the Waste Management System Description (WMSD), the Waste Management System Requirements (WMSR), and the Physical System Requirements documents provide the technical basis for the PCSB. Changes to the PCSB will be approved by the Pregrain Change Control Board (PCCB)In addition to the PCCB, the Energy System Acquisition Advisory Board Baseline CCB (ESAAB BCCB) will perform control functions relating to Total Project Cost (TPC) and major schedule milestones for the Yucca Mountain Site Characterization Project and the Monitored Retrievable Storage (MRS) Project

  7. Prognostic value of repeated {sup 123}I-metaiodobenzylguanidine imaging in patients with dilated cardiomyopathy with congestive heart failure before and after optimized treatments. Comparison with neurohumoral factors

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Toshiki; Tsutamoto, Takayoshi; Maeda, Keiko; Kusukawa, Junya; Kinoshita, Masahiko [Shiga Univ. of Medical Science, Otsu (Japan)

    2002-06-01

    The present study was undertaken to assess whether repeated measurement of cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) imaging parameters before and after optimized treatments is useful for predicting the prognosis of patients with congestive heart failure (CHF) resulting from dilated cardiomyopathy (DCM). The subjects were 85 consecutive patients with DCM who had a left ventricular ejection fraction (LVEF) of less than 45%. The MIBG and the concentrations of neurohumoral factors were measured at baseline and after 6 months of optimized treatments. Cox proportional hazards analysis was performed to assess the various parameters before and after treatment. Twenty-three patients had a cardiac event (12 died; 11 hospitalized) during a mean follow-up period of 2 years. Although there was no difference between the baseline heart to mediastinum (H/M) ratio measured by MIBG between survivors and nonsurvivors, the H/M ratio was significantly decreased in nonsurvivors after 6 months. Multivariate analysis revealed that a high plasma concentration of brain natriuretic peptide level after 6 months (p=0.0049) and absolute changes in the H/M ratio (p=0.0046) were independent predictors of mortality. Comparison of the H/M ratio on MIBG imaging before and after optimized additional treatment provided useful information for predicting mortality and was independent of clinical and neurohumoral factors previously shown to be associated with poor prognosis in patients with DCM. (author)

  8. Violation of the Sphericity Assumption and Its Effect on Type-I Error Rates in Repeated Measures ANOVA and Multi-Level Linear Models (MLM).

    Science.gov (United States)

    Haverkamp, Nicolas; Beauducel, André

    2017-01-01

    We investigated the effects of violations of the sphericity assumption on Type I error rates for different methodical approaches of repeated measures analysis using a simulation approach. In contrast to previous simulation studies on this topic, up to nine measurement occasions were considered. Effects of the level of inter-correlations between measurement occasions on Type I error rates were considered for the first time. Two populations with non-violation of the sphericity assumption, one with uncorrelated measurement occasions and one with moderately correlated measurement occasions, were generated. One population with violation of the sphericity assumption combines uncorrelated with highly correlated measurement occasions. A second population with violation of the sphericity assumption combines moderately correlated and highly correlated measurement occasions. From these four populations without any between-group effect or within-subject effect 5,000 random samples were drawn. Finally, the mean Type I error rates for Multilevel linear models (MLM) with an unstructured covariance matrix (MLM-UN), MLM with compound-symmetry (MLM-CS) and for repeated measures analysis of variance (rANOVA) models (without correction, with Greenhouse-Geisser-correction, and Huynh-Feldt-correction) were computed. To examine the effect of both the sample size and the number of measurement occasions, sample sizes of n = 20, 40, 60, 80, and 100 were considered as well as measurement occasions of m = 3, 6, and 9. With respect to rANOVA, the results plead for a use of rANOVA with Huynh-Feldt-correction, especially when the sphericity assumption is violated, the sample size is rather small and the number of measurement occasions is large. For MLM-UN, the results illustrate a massive progressive bias for small sample sizes ( n = 20) and m = 6 or more measurement occasions. This effect could not be found in previous simulation studies with a smaller number of measurement occasions. The

  9. 40 CFR 1042.825 - Baseline determination.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Baseline determination. 1042.825... Provisions for Remanufactured Marine Engines § 1042.825 Baseline determination. (a) For the purpose of this... not valid. (f) Use good engineering judgment for all aspects of the baseline determination. We may...

  10. Oscillation Baselining and Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-27

    PNNL developed a new tool for oscillation analysis and baselining. This tool has been developed under a new DOE Grid Modernization Laboratory Consortium (GMLC) Project (GM0072 - “Suite of open-source applications and models for advanced synchrophasor analysis”) and it is based on the open platform for PMU analysis. The Oscillation Baselining and Analysis Tool (OBAT) performs the oscillation analysis and identifies modes of oscillations (frequency, damping, energy, and shape). The tool also does oscillation event baselining (fining correlation between oscillations characteristics and system operating conditions).

  11. Incremental Value of Repeated Risk Factor Measurements for Cardiovascular Disease Prediction in Middle-Aged Korean Adults: Results From the NHIS-HEALS (National Health Insurance System-National Health Screening Cohort).

    Science.gov (United States)

    Cho, In-Jeong; Sung, Ji Min; Chang, Hyuk-Jae; Chung, Namsik; Kim, Hyeon Chang

    2017-11-01

    Increasing evidence suggests that repeatedly measured cardiovascular disease (CVD) risk factors may have an additive predictive value compared with single measured levels. Thus, we evaluated the incremental predictive value of incorporating periodic health screening data for CVD prediction in a large nationwide cohort with periodic health screening tests. A total of 467 708 persons aged 40 to 79 years and free from CVD were randomly divided into development (70%) and validation subcohorts (30%). We developed 3 different CVD prediction models: a single measure model using single time point screening data; a longitudinal average model using average risk factor values from periodic screening data; and a longitudinal summary model using average values and the variability of risk factors. The development subcohort included 327 396 persons who had 3.2 health screenings on average and 25 765 cases of CVD over 12 years. The C statistics (95% confidence interval [CI]) for the single measure, longitudinal average, and longitudinal summary models were 0.690 (95% CI, 0.682-0.698), 0.695 (95% CI, 0.687-0.703), and 0.752 (95% CI, 0.744-0.760) in men and 0.732 (95% CI, 0.722-0.742), 0.735 (95% CI, 0.725-0.745), and 0.790 (95% CI, 0.780-0.800) in women, respectively. The net reclassification index from the single measure model to the longitudinal average model was 1.78% in men and 1.33% in women, and the index from the longitudinal average model to the longitudinal summary model was 32.71% in men and 34.98% in women. Using averages of repeatedly measured risk factor values modestly improves CVD predictability compared with single measurement values. Incorporating the average and variability information of repeated measurements can lead to great improvements in disease prediction. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02931500. © 2017 American Heart Association, Inc.

  12. Evaluation of Pulmonary and Systemic Toxicity of Oil Dispersant (COREXIT EC9500A following Acute Repeated Inhalation Exposure

    Directory of Open Access Journals (Sweden)

    Jenny R. Roberts

    2014-01-01

    Full Text Available Introduction Oil spill cleanup workers come into contact with numerous potentially hazardous chemicals derived from the oil spills, as well as chemicals applied for mitigation of the spill, including oil dispersants. In response to the Deepwater Horizon Macondo well oil spill in the Gulf of Mexico in 2010, a record volume of the oil dispersant, COREXIT EC9500A, was delivered via aerial applications, raising concern regarding potential health effects that may result from pulmonary exposure to the dispersant. Methods The current study examined the effects on pulmonary functions, cardiovascular functions, and systemic immune responses in rats to acute repeated inhalation exposure of COREXIT EC9500A at 25 mg/m 3 , five hours per day, over nine work days, or filtered air (control. At one and seven days following the last exposure, a battery of parameters was measured to evaluate lung function, injury, and inflammation; cardiovascular function; peripheral vascular responses; and systemic immune responses. Results No significant alterations in airway reactivity were observed at one or seven days after exposure either in baseline values or following metha-choline (MCh inhalation challenge. Although there was a trend for an increase in lung neutrophils and phagocyte oxidant production at one-day post exposure, there were no significant differences in parameters of lung inflammation. In addition, increased blood monocytes and neutrophils, and decreased lymphocyte numbers at one-day post exposure also did not differ significantly from air controls, and no alterations in splenocyte populations, or serum or spleen immunoglobulin M (IgM to antigen were observed. There were no significant differences in peripheral vascular responsiveness to vasoconstrictor and vasodilator agonists or in blood pressure (BP responses to these agents; however, the baseline heart rate (HR and HR responses to isoproterenol (ISO were significantly elevated at one-day post exposure

  13. Repeatability of quantitative sensory testing in healthy cats in a clinical setting with comparison to cats with osteoarthritis.

    Science.gov (United States)

    Addison, Elena S; Clements, Dylan N

    2017-12-01

    Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.

  14. Effect of hip braces on brake response time: Repeated measures designed study.

    Science.gov (United States)

    Dammerer, Dietmar; Waidmann, Cornelia; Huber, Dennis G; Krismer, Martin; Haid, Christian; Liebensteiner, Michael C

    2017-08-01

    The question whether or not a patient with a hip brace should drive a car is of obvious importance because the advice given to patients to resume driving is often anecdotal as few scientific data are available on this specific subject. To assess driving ability (brake response time) with commonly used hip braces. Repeated measures design. Brake response time was assessed under six conditions: (1) without a brace (control), (2) with a typical postoperative hip brace with adjustable range of motion and the settings: unrestricted, (3) flexion limited to 70°, (4) extension blocked at 20° hip flexion, (5) both flexion and extension limited (20°/70°) and (6) an elastic hip bandage. Brake response time was assessed using a custom-made driving simulator as used in previous studies. The participants were a convenience sample of able-bodied participants. A total of 70 participants (35 women and 35 men) participated in our study. Mean age was 31.1 (standard deviation: 10.6; range: 21.7-66.4) years. A significant within-subject effect for brake response time was found ( p = 0.009), but subsequent post hoc analyses revealed no significant differences between control and the other settings. Based on our findings, it does not seem mandatory to recommend driving abstinence for patients wearing a hip orthosis. We suggest that our results be interpreted with caution, because (1) an underlying pathological hip condition needs to be considered, (2) the ability to drive a car safely is multifactorial and brake response time is only one component thereof and (3) brake response time measurements were performed only with healthy participants. Clinical relevance Hip braces are used in the context of joint-preserving and prosthetic surgery of the hip. Therefore, clinicians are confronted with the question whether to allow driving a car with the respective hip brace or not. Our data suggest that hip braces do not impair brake response time.

  15. NETWORK DESIGN IN CLOSE-RANGE PHOTOGRAMMETRY WITH SHORT BASELINE IMAGES

    Directory of Open Access Journals (Sweden)

    L. Barazzetti

    2017-08-01

    Full Text Available The avaibility of automated software for image-based 3D modelling has changed the way people acquire images for photogrammetric applications. Short baseline images are required to match image points with SIFT-like algorithms, obtaining more images than those necessary for “old fashioned” photogrammetric projects based on manual measurements. This paper describes some considerations on network design for short baseline image sequences, especially on precision and reliability of bundle adjustment. Simulated results reveal that the large number of 3D points used for image orientation has very limited impact on network precision.

  16. Reliability and concurrent validity of postural asymmetry measurement in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Prowse, Ashleigh; Aslaksen, Berit; Kierkegaard, Marie; Furness, James; Gerdhem, Paul; Abbott, Allan

    2017-01-18

    To investigate the reliability and concurrent validity of the Baseline ® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes. This is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline ® Body Level/Scoliosis meter. Spearman's correlation analyses were used to estimate concurrent validity between the Baseline ® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer. There was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627). The Baseline ® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity.

  17. Repeatability of Bolus Kinetics Ultrasound Perfusion Imaging for the Quantification of Cerebral Blood Flow

    NARCIS (Netherlands)

    Vinke, Elisabeth J.; Eyding, Jens; de Korte, Chris L.; Slump, Cornelis H.; van der Hoeven, Johannes G.; Hoedemaekers, Cornelia W.E.

    2017-01-01

    Ultrasound perfusion imaging (UPI) can be used for the quantification of cerebral perfusion. In a neuro-intensive care setting, repeated measurements are required to evaluate changes in cerebral perfusion and monitor therapy. The aim of this study was to determine the repeatability of UPI in

  18. Detecting CP violation in a single neutrino oscillation channel at very long baselines

    International Nuclear Information System (INIS)

    Latimer, D. C.; Escamilla, J.; Ernst, D. J.

    2007-01-01

    We propose a way of detecting CP violation in a single neutrino oscillation channel at very long baselines (on the order of several thousands of kilometers), given precise knowledge of the smallest mass-squared difference. It is shown that CP violation can be characterized by a shift in L/E of the peak oscillation in the ν e -ν μ appearance channel, both in vacuum and in matter. In fact, matter effects enhance the shift at a fixed energy. We consider the case in which sub-GeV neutrinos are measured with varying baseline and also the case of a fixed baseline. For the varied baseline, accurate knowledge of the absolute neutrino flux would not be necessary; however, neutrinos must be distinguishable from antineutrinos. For the fixed baseline, it is shown that CP violation can be distinguished if the mixing angle θ 13 were known

  19. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry.

    Science.gov (United States)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H; Tol, Johannes L; Verhaar, Jan A N; Weir, Adam

    2016-08-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of measuring muscle strength. The reliability of HHD has not been determined in athletes with acute hamstring injuries. Objectives To determine the intertester reliability and the prognostic value of hamstring HHD strength measurement in acute hamstring injuries. Methods We measured knee flexion strength with HHD in 75 athletes at 2 visits, at baseline (within 5 days of hamstring injury) and follow-up (5 to 7 days after the baseline measurement). We assessed isometric hamstring strength in 15° and 90° of knee flexion. Reliability analysis testing was performed by 2 testers independently at the follow-up visit. We recorded the time needed to return to play (RTP) up to 6 months following baseline. Results The intraclass correlation coefficients of the strength measurements in injured hamstrings were between 0.75 and 0.83. There was a statistically significant but weak correlation between the time to RTP and the strength deficit at 15° of knee flexion measured at baseline (Spearman r = 0.25, P = .045) and at the follow-up visit (Spearman r = 0.26, P = .034). Up to 7% of the variance in time to RTP is explained by this strength deficit. None of the other strength variables were significantly correlated with time to RTP. Conclusion Hamstring strength can be reliably measured with HHD in athletes with acute hamstring injuries. The prognostic value of strength measurements is limited, as there is only a weak association between the time to RTP and hamstring strength deficit after acute injury. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther 2016;46(8):689-696. Epub 12 May 2016. doi:10.2519/jospt.2016.6363.

  20. Opening Doors to Recovery: Recidivism and Recovery Among Persons With Serious Mental Illnesses and Repeated Hospitalizations.

    Science.gov (United States)

    Compton, Michael T; Kelley, Mary E; Pope, Alicia; Smith, Kelly; Broussard, Beth; Reed, Thomas A; DiPolito, June A; Druss, Benjamin G; Li, Charles; Lott Haynes, Nora

    2016-02-01

    Repeated hospitalizations and arrests or incarcerations diminish the ability of individuals with serious mental illnesses to pursue recovery. Community mental health systems need new models to address recidivism as well as service fragmentation, lack of engagement by local stakeholders, and poor communication between mental health providers and the police. This study examined the initial effects on institutional recidivism and measures of recovery among persons enrolled in Opening Doors to Recovery, an intensive, team-based community support program for persons with mental illness and a history of inpatient psychiatric recidivism. A randomized controlled trial of the model is underway. The number of hospitalizations, days hospitalized, and arrests (all from state administrative sources) in the year before enrollment and during the first 12 months of enrollment in the program were compared. Longitudinal trajectories of recovery-using three self-report and five clinician-rated measures-were examined. Analyses accounted for baseline symptom severity and intensity of involvement in the program. One hundred participants were enrolled, and 72 were included in the analyses. Hospitalizations decreased, from 1.9±1.6 to .6±.9 (precovery measures, and trajectories of improvement were apparent across the entire follow-up period. Opening Doors to Recovery holds promise as a new service approach for reducing hospital recidivism and promoting recovery in community mental health systems and is deserving of further controlled testing.

  1. Repeated measurement of nasal lavage fluid chemokines in school-age children with asthma.

    Science.gov (United States)

    Noah, Terry L; Tudor, Gail E; Ivins, Sally S; Murphy, Paula C; Peden, David B; Henderson, Frederick W

    2006-02-01

    Inflammatory processes at the mucosal surface may play a role in maintenance of asthma pathophysiology. Cross-sectional studies in asthmatic patients suggest that chemokines such as interleukin 8 (IL-8) are overproduced by respiratory epithelium. To test the hypothesis that chemokine levels are persistently elevated in the respiratory secretions of asthmatic children at a stable baseline. We measured nasal lavage fluid (NLF) levels of chemokines and other mediators at 3- to 4-month intervals in a longitudinal study of asthmatic children, with nonasthmatic siblings as controls. In a linear mixed-model analysis, both family and day of visit had significant effects on nasal mediators. Thus, data for 12 asthmatic-nonasthmatic sibling pairs who had 3 or more same-day visits were analyzed separately. For sibling pairs, median eosinophil cationic protein levels derived from serial measurements in NLF were elevated in asthmatic patients compared with nonasthmatic patients, with a near-significant tendency for elevation of total protein and eotaxin levels as well. However, no significant differences were found for IL-8 or several other chemokines. Ratios of IL-13 or IL-5 to interferon-gamma released by house dust mite antigen-stimulated peripheral blood mononuclear cells, tested on a single occasion, were significantly increased for asthmatic patients. Substantial temporal and family-related variability exists in nasal inflammation in asthmatic children. Although higher levels of eosinophil cationic protein are usually present in NLF of patients with stable asthma compared with patients without asthma, chemokines other than eotaxin are not consistently increased. Eosinophil activation at the mucosal surface is a more consistent predictor of asthmatic symptoms than nonspecific elevation of epithelium-derived inflammatory chemokine levels.

  2. 33 CFR 2.20 - Territorial sea baseline.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line.... Normally, the territorial sea baseline is the mean low water line along the coast of the United States...

  3. Mass hierarchy sensitivity of medium baseline reactor neutrino experiments with multiple detectors

    Directory of Open Access Journals (Sweden)

    Hong-Xin Wang

    2017-05-01

    Full Text Available We report the neutrino mass hierarchy (MH determination of medium baseline reactor neutrino experiments with multiple detectors, where the sensitivity of measuring the MH can be significantly improved by adding a near detector. Then the impact of the baseline and target mass of the near detector on the combined MH sensitivity has been studied thoroughly. The optimal selections of the baseline and target mass of the near detector are ∼12.5 km and ∼4 kton respectively for a far detector with the target mass of 20 kton and the baseline of 52.5 km. As typical examples of future medium baseline reactor neutrino experiments, the optimal location and target mass of the near detector are selected for the specific configurations of JUNO and RENO-50. Finally, we discuss distinct effects of the reactor antineutrino energy spectrum uncertainty for setups of a single detector and double detectors, which indicate that the spectrum uncertainty can be well constrained in the presence of the near detector.

  4. Program Baseline Change Control Board charter

    International Nuclear Information System (INIS)

    1993-02-01

    The purpose of this Charter is to establish the Program Baseline Change Control Board (PBCCB) for the Office of Civilian Radioactive Waste Management (OCRWM) Program, and to describe its organization, responsibilities, and basic methods of operation. Guidance for implementing this Charter is provided by the OCRWM Baseline Management Plan (BMP) and OCRWM Program Baseline Change Control Procedure

  5. Anesthetic efficacy of a repeated intraosseous injection given 30 min following an inferior alveolar nerve block/intraosseous injection.

    OpenAIRE

    Reitz, J.; Reader, A.; Nist, R.; Beck, M.; Meyers, W. J.

    1998-01-01

    To determine whether a repeated intraosseous (IO) injection would increase or prolong pulpal anesthesia, we measured the degree of anesthesia obtained by a repeated IO injection given 30 min following a combination inferior alveolar nerve block/intraosseous injection (IAN/IO) in mandibular second premolars and in first and second molars. Using a repeated-measures design, we randomly assigned 38 subjects to receive two combinations of injections at two separate appointments. The combinations w...

  6. Baseline Gray- and White Matter Volume Predict Successful Weight Loss in the Elderly

    Science.gov (United States)

    Mokhtari, Fatemeh; Paolini, Brielle M.; Burdette, Jonathan H.; Marsh, Anthony P.; Rejeski, W. Jack; Laurienti, Paul J.

    2016-01-01

    Objective The purpose of this study is to investigate if structural brain phenotypes can be used to predict weight loss success following behavioral interventions in older adults that are overweight or obese and have cardiometabolic dysfunction. Methods A support vector machine (SVM) with a repeated random subsampling validation approach was used to classify participants into the upper and lower halves of the weight loss distribution following 18 months of a weight loss intervention. Predictions were based on baseline brain gray matter (GM) and white matter (WM) volume from 52 individuals that completed the intervention and a magnetic resonance imaging session. Results The SVM resulted in an average classification accuracy of 72.62 % based on GM and WM volume. A receiver operating characteristic analysis indicated that classification performance was robust based on an area under the curve of 0.82. Conclusions Our findings suggest that baseline brain structure is able to predict weight loss success following 18 months of treatment. The identification of brain structure as a predictor of successful weight loss is an innovative approach to identifying phenotypes for responsiveness to intensive lifestyle interventions. This phenotype could prove useful in future research focusing on the tailoring of treatment for weight loss. PMID:27804273

  7. Developing the Pieta House Suicide Intervention Model: a quasi-experimental, repeated measures design.

    Science.gov (United States)

    Surgenor, Paul Wg; Freeman, Joan; O'Connor, Cindy

    2015-01-01

    While most crisis intervention models adhere to a generalised theoretical framework, the lack of clarity around how these should be enacted has resulted in a proliferation of models, most of which have little to no empirical support. The primary aim of this research was to propose a suicide intervention model that would resolve the client's suicidal crisis by decreasing their suicidal ideation and improve their outlook through enhancing a range of protective factors. The secondary aim was to assess the impact of this model on negative and positive outlook. A quasi-experimental, pre-test post-test repeated measures design was employed. A questionnaire assessing self-esteem, depression, and positive and negative suicidal ideation was administered to the same participants pre- and post- therapy facilitating paired responses. Multiple analysis of variance and paired-samples t-tests were conducted to establish whether therapy using the PH-SIM had a significant effect on the clients' negative and positive outlook. Analyses revealed a statistically significant effect of therapy for depression, negative suicidal ideation, self-esteem, and positive suicidal ideation. Negative outlook was significantly lower after therapy and positive outlook significantly higher. The decreased negative outlook and increased positive outlook following therapy provide some support for the proposed model in fulfilling its role, though additional research is required to establish the precise role of the intervention model in achieving this.

  8. PTSD and DNA Methylation in Select Immune Function Gene Promoter Regions: A Repeated Measures Case-control Study of U.S. Military Service Members

    Science.gov (United States)

    2013-06-24

    other relevant exposures which may influ- ence DNA methylation , such as dietary factors ( folate , vitamin B12 intake) (Fenech, 2001; Piyathilake and...ARTICLE published: 24 June 2013 doi: 10.3389/fpsyt.2013.00056 PTSD and DNA methylation in select immune function gene promoter regions: a repeated measures...largely unknown. Dis- tinct expression signatures for PTSD have been found, in particular for immune activation transcripts. DNA methylation may be

  9. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    Science.gov (United States)

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  10. Depression CBT treatment gains among HIV-infected persons with a history of injection drug use varies as a function of baseline substance use.

    Science.gov (United States)

    Labbe, Allison K; O'Cleirigh, Conall M; Stein, Michael; Safren, Steven A

    2015-01-01

    Depression and substance use, the most common comorbidities with HIV, are both associated with poor treatment outcomes and accelerated HIV disease progression. Though previous research has demonstrated short-term and follow-up success for cognitive behavioral therapy for adherence and depression (CBT-AD) on depression outcomes among patients with HIV in care and among patients with HIV in active substance abuse treatment for injection drug use (IDU), there is little information regarding possible moderating effects of active use versus abstinence on depression treatment gains. The present study aimed to examine recent substance use at treatment initiation as a moderator of the acute and maintenance effects of CBT-AD on depression. We used data from a two-arm, randomized controlled trial (N = 89) comparing CBT-AD to enhanced treatment as usual in individuals in treatment for IDU. To test whether depression at time of presentation affected outcomes, repeated-measures ANOVAs were conducted for two time frames: (1) acute phase (baseline to post-treatment) (acute) and (2) maintenance phase (baseline to 12-month follow-up). To further examine maintenance of gains, we additionally looked at post-treatment to 12-month follow-up. Depression scores derived from the clinical global impression for severity and the Montgomery-Asberg depression rating scale (MADRS) served as the primary outcome variables. Acute (baseline post treatment) moderation effects were found for those patients endorsing active drug use at baseline in the CBT-AD condition, who demonstrated the greatest reductions in MADRS scores at post-treatment (F[1,76] = 6.78, p = .01) and follow-up (F[1,61] = 5.46, p = .023). Baseline substance use did not moderate differences from post-treatment to 12-month follow-up as depression treatment gains that occurred acutely from baseline to post-treatment were maintained across both patients engaged in substance use and abstainers. We conclude that CBT

  11. Gender, obesity and repeated elevation of C-reactive protein: data from the CARDIA cohort.

    Directory of Open Access Journals (Sweden)

    Shinya Ishii

    Full Text Available C-reactive Protein (CRP measurements above 10 mg/L have been conventionally treated as acute inflammation and excluded from epidemiologic studies of chronic inflammation. However, recent evidence suggest that such CRP elevations can be seen even with chronic inflammation. The authors assessed 3,300 participants in The Coronary Artery Risk Development in Young Adults study, who had two or more CRP measurements between 1992/3 and 2005/6 to a investigate characteristics associated with repeated CRP elevation above 10 mg/L; b identify subgroups at high risk of repeated elevation; and c investigate the effect of different CRP thresholds on the probability of an elevation being one-time rather than repeated. 225 participants (6.8% had one-time and 103 (3.1% had repeated CRP elevation above 10 mg/L. Repeated elevation was associated with obesity, female gender, low income, and sex hormone use. The probability of an elevation above 10 mg/L being one-time rather than repeated was lowest (51% in women with body mass index above 31 kg/m(2, compared to 82% in others. These findings suggest that CRP elevations above 10 mg/L in obese women are likely to be from chronic rather than acute inflammation, and that CRP thresholds above 10 mg/L may be warranted to distinguish acute from chronic inflammation in obese women.

  12. Fostering repeat donations in Ghana.

    Science.gov (United States)

    Owusu-Ofori, S; Asenso-Mensah, K; Boateng, P; Sarkodie, F; Allain, J-P

    2010-01-01

    Most African countries are challenged in recruiting and retaining voluntary blood donors by cost and other complexities and in establishing and implementing national blood policies. The availability of replacement donors who are a cheaper source of blood has not enhanced repeat voluntary donor initiatives. An overview of activities for recruiting and retaining voluntary blood donors was carried out. Donor records from mobile sessions were reviewed from 2002 to 2008. A total of 71,701 blood donations; 45,515 (63.5%) being voluntary donations with 11,680 (25%) repeat donations were collected during the study period. Donations from schools and colleges contributed a steady 60% of total voluntary whilst radio station blood drives increased contribution from 10 to 27%. Though Muslim population is less than 20%, blood collection was above the 30-donation cost-effectiveness threshold with a repeat donation trend reaching 60%. In contrast Christian worshippers provided donations. Repeat donation trends amongst school donors and radio blood drives were 20% and 70% respectively. Repeat donations rates have been variable amongst different blood donor groups in Kumasi, Ghana. The impact of community leaders in propagating altruism cannot be overemphasized. Programs aiming at motivating replacement donors to be repeat donors should be developed and assessed. Copyright 2009 The International Association for Biologicals. All rights reserved.

  13. A study on radiographic repeat rate data of several hospitals in Jeddah

    International Nuclear Information System (INIS)

    Al-Malki, M.A.; Abulfaraj, W.H.; Bhuiyan, S.I.; Kinsara, A.A.

    2003-01-01

    Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94% and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m 2 . As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about US$1.82 million (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture. (author)

  14. A study on radiographic repeat rate data of several hospitals in Jeddah

    Energy Technology Data Exchange (ETDEWEB)

    Al-Malki, M.A.; Abulfaraj, W.H.; Bhuiyan, S.I.; Kinsara, A.A

    2003-07-01

    Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94% and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m{sup 2}. As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about US$1.82 million (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture. (author)

  15. Medial temporal lobe-dependent repetition suppression and enhancement due to implicit versus explicit processing of individual repeated search displays

    Directory of Open Access Journals (Sweden)

    Thomas eGeyer

    2012-10-01

    Full Text Available Using visual search, functional magnetic resonance imaging (fMRI and patient studies have demonstrated that medial temporal lobe (MTL structures differentiate repeated from novel displays – even when observers are unaware of display repetitions. This suggests a role for MTL in both explicit and, importantly, implicit learning of repeated sensory information (Greene et al., 2007. However, recent behavioral studies suggest, by examining visual search and recognition performance concurrently, that observers have explicit knowledge of at least some of the repeated displays (Geyer et al., 2010. The aim of the present fMRI study was thus to contribute new evidence regarding the contribution of MTL structures to explicit versus implicit learning in visual search. It was found that MTL activation was increased for explicit and, respectively, decreased for implicit relative to baseline displays. These activation differences were most pronounced in left anterior parahippocampal cortex, especially when observers were highly trained on the repeated displays. The data are taken to suggest that explicit and implicit memory processes are linked within MTL structures, but expressed via functionally separable mechanisms (repetition enhancement vs. -suppression. They further show that repetition effects in visual search would have to be investigated at the display level.

  16. EML Chester - 1982. Annual report of the Regional Baseline Station at Chester, New Jersey

    International Nuclear Information System (INIS)

    Volchok, H.L.

    1982-11-01

    The Environmental Measurements Laboratory (EML) has maintained a regional baseline station at Chester, New Jersey since 1976. The site provides EML with a remote, rural facility for carrying out regional baseline research and for testing field equipment. This report updates the various programs underway at the Chester site. Separate abstracts have been prepared for the included papers

  17. Repeated tongue lift movement induces neuroplasticity in corticomotor control of tongue and jaw muscles in humans.

    Science.gov (United States)

    Komoda, Yoshihiro; Iida, Takashi; Kothari, Mohit; Komiyama, Osamu; Baad-Hansen, Lene; Kawara, Misao; Sessle, Barry; Svensson, Peter

    2015-11-19

    This study investigated the effect of repeated tongue lift training (TLT) on the excitability of the corticomotor representation of the human tongue and jaw musculature. Sixteen participants performed three series of TLT for 41 min on each of 5 consecutive days. Each TLT series consisted of two pressure levels (5 kPa and 10 kPa). All participants underwent transcranial magnetic stimulation (TMS) and electromyographic (EMG) recordings of motor evoked potentials (MEPs) in four sessions: (1) before TLT on Day 1 (baseline), (2) after TLT on Day 1, (3) before TLT on Day 5, and (4) after TLT on Day 5. EMG recordings from the left and right tongue dorsum and masseter muscles were made at three pressure levels (5 kPa, 10 kPa, 100% tongue lift), and tongue, masseter, and first dorsal interosseous (FDI) MEPs were measured. There were no significant day-to-day differences in the tongue pressure during maximum voluntary contractions. The amplitudes and thresholds of tongue and masseter MEPs after TLT on Day 5 were respectively higher and lower than before TLT on Day 1 (P<0.005), and there was also a significant increase in tongue and masseter MEP areas; no significant changes occurred in MEP onset latencies. FDI MEP parameters (amplitude, threshold, area, latency) were not significantly different between the four sessions. Our findings suggest that repeated TLT can trigger neuroplasticity reflected in increased excitability of the corticomotor representation of not only the tongue muscles but also the masseter muscles. Copyright © 2015. Published by Elsevier B.V.

  18. Evaluation of Pulmonary and Systemic Toxicity of Oil Dispersant (COREXIT EC9500A(®)) Following Acute Repeated Inhalation Exposure.

    Science.gov (United States)

    Roberts, Jenny R; Anderson, Stacey E; Kan, Hong; Krajnak, Kristine; Thompson, Janet A; Kenyon, Allison; Goldsmith, William T; McKinney, Walter; Frazer, David G; Jackson, Mark; Fedan, Jeffrey S

    2014-01-01

    Oil spill cleanup workers come into contact with numerous potentially hazardous chemicals derived from the oil spills, as well as chemicals applied for mitigation of the spill, including oil dispersants. In response to the Deepwater Horizon Macondo well oil spill in the Gulf of Mexico in 2010, a record volume of the oil dispersant, COREXIT EC9500A, was delivered via aerial applications, raising concern regarding potential health effects that may result from pulmonary exposure to the dispersant. The current study examined the effects on pulmonary functions, cardiovascular functions, and systemic immune responses in rats to acute repeated inhalation exposure of COREXIT EC9500A at 25 mg/m(3), five hours per day, over nine work days, or filtered air (control). At one and seven days following the last exposure, a battery of parameters was measured to evaluate lung function, injury, and inflammation; cardiovascular function; peripheral vascular responses; and systemic immune responses. No significant alterations in airway reactivity were observed at one or seven days after exposure either in baseline values or following methacholine (MCh) inhalation challenge. Although there was a trend for an increase in lung neutrophils and phagocyte oxidant production at one-day post exposure, there were no significant differences in parameters of lung inflammation. In addition, increased blood monocytes and neutrophils, and decreased lymphocyte numbers at one-day post exposure also did not differ significantly from air controls, and no alterations in splenocyte populations, or serum or spleen immunoglobulin M (IgM) to antigen were observed. There were no significant differences in peripheral vascular responsiveness to vasoconstrictor and vasodilator agonists or in blood pressure (BP) responses to these agents; however, the baseline heart rate (HR) and HR responses to isoproterenol (ISO) were significantly elevated at one-day post exposure, with resolution by day 7. In summary, acute

  19. Repeated passive stretching : Acute effect on the passive muscle moment and extensibility of short hamstrings

    NARCIS (Netherlands)

    Halbertsma, JPK; Mulder, [No Value; Goeken, LNH; Eisma, WH; Mulder, I.; Göeken, L.N.

    Objective: To examine the response of short hamstring muscles to repeated passive stretching. Design: A repeated measures design. Setting: A university laboratory for human movement analysis in a department of rehabilitation. Subjects: Students (7 men, 10 women) from the Department of Human Movement

  20. Unstable systems and repeated measurements. II

    International Nuclear Information System (INIS)

    Exner, P.

    1977-01-01

    Two examples are treated. In the first, the chamber structure is only assumed to be periodic and P(t) is an exponential. In the second example no specific assumption is made about the primary decay law and the measuring device is structured as an idealized spark chamber. This example contains the results by Beskow and Nilsson as a special case. (author)

  1. Measuring Aseismic Slip through Characteristically Repeating Earthquakes at the Mendocino Triple Junction, Northern California

    Science.gov (United States)

    Materna, K.; Taira, T.; Burgmann, R.

    2016-12-01

    The Mendocino Triple Junction (MTJ), at the transition point between the San Andreas fault system, the Mendocino Transform Fault, and the Cascadia Subduction Zone, undergoes rapid tectonic deformation and produces more large (M>6.0) earthquakes than any region in California. Most of the active faults of the triple junction are located offshore, making it difficult to characterize both seismic slip and aseismic creep. In this work, we study aseismic creep rates near the MTJ using characteristically repeating earthquakes (CREs) as indicators of creep rate. CREs are generally interpreted as repeated failures of the same seismic patch within an otherwise creeping fault zone; as a consequence, the magnitude and recurrence time of the CREs can be used to determine a fault's creep rate through empirically calibrated scaling relations. Using seismic data from 2010-2016, we identify CREs as recorded by an array of eight 100-Hz PBO borehole seismometers deployed in the Cape Mendocino area. For each event pair with epicenters less than 30 km apart, we compute the cross-spectral coherence of 20 seconds of data starting one second before the P-wave arrival. We then select pairs with high coherence in an appropriate frequency band, which is determined uniquely for each event pair based on event magnitude, station distance, and signal-to-noise ratio. The most similar events (with median coherence above 0.95 at two or more stations) are selected as CREs and then grouped into CRE families, and each family is used to infer a local creep rate. On the Mendocino Transform Fault, we find relatively high creep rates of >5 cm/year that increase closer to the Gorda Ridge. Closer to shore and to the MTJ itself, we find many families of repeaters on and off the transform fault with highly variable creep rates, indicative of the complex deformation that takes place there.

  2. Focal hand dystonia: individualized intervention with repeated application of repetitive transcranial magnetic stimulation.

    Science.gov (United States)

    Kimberley, Teresa Jacobson; Borich, Michael R; Schmidt, Rebekah L; Carey, James R; Gillick, Bernadette

    2015-04-01

    To examine for individual factors that may predict response to inhibitory repetitive transcranial magnetic stimulation (rTMS) in focal hand dystonia (FHD); to present the method for determining optimal stimulation to increase inhibition in a given patient; and to examine individual responses to prolonged intervention. Single-subject design to determine optimal parameters to increase inhibition for a given subject and to use the selected parameters once per week for 6 weeks, with 1-week follow-up, to determine response. Clinical research laboratory. A volunteer sample of subjects with FHD (N = 2). One participant had transcranial magnetic stimulation responses indicating impaired inhibition, and the other had responses within normative limits. There were 1200 pulses of 1-Hz rTMS delivered using 4 different stimulation sites/intensity combinations: primary motor cortex at 90% or 110% of resting motor threshold (RMT) and dorsal premotor cortex (PMd) at 90% or 110% of RMT. The parameters producing the greatest within-session increase in cortical silent period (CSP) duration were then used as the intervention. Response variables included handwriting pressure and velocity, subjective symptom rating, CSP, and short latency intracortical inhibition and facilitation. The individual with baseline transcranial magnetic stimulation responses indicating impaired inhibition responded favorably to the repeated intervention, with reduced handwriting force, an increase in the CSP, and subjective report of moderate symptom improvement at 1-week follow-up. The individual with normative baseline responses failed to respond to the intervention. In both subjects, 90% of RMT to the PMd produced the greatest lengthening of the CSP and was used as the intervention. An individualized understanding of neurophysiological measures can be an indicator of responsiveness to inhibitory rTMS in focal dystonia, with further work needed to determine likely responders versus nonresponders. Copyright

  3. Repeated DNA sequences in fungi

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, S K

    1974-11-01

    Several fungal species, representatives of all broad groups like basidiomycetes, ascomycetes and phycomycetes, were examined for the nature of repeated DNA sequences by DNA:DNA reassociation studies using hydroxyapatite chromatography. All of the fungal species tested contained 10 to 20 percent repeated DNA sequences. There are approximately 100 to 110 copies of repeated DNA sequences of approximately 4 x 10/sup 7/ daltons piece size of each. Repeated DNA sequence homoduplexes showed on average 5/sup 0/C difference of T/sub e/50 (temperature at which 50 percent duplexes dissociate) values from the corresponding homoduplexes of unfractionated whole DNA. It is suggested that a part of repetitive sequences in fungi constitutes mitochondrial DNA and a part of it constitutes nuclear DNA. (auth)

  4. The relationship of social support concept and repeat mammography among Iranian women.

    Science.gov (United States)

    Farhadifar, Fariba; Taymoori, Parvaneh; Bahrami, Mitra; Zarea, Shamsy

    2015-10-24

    Breast cancer ranks as the first most common cancer among the Iranian women. The regular repeat of mammography with 1-2 year intervals leads to the increased efficiency of early detection of breast cancer. The present study examined the predictors of repeat mammography. It was hypothesized that higher social support is connected with mammography repeat. A cross-sectional study was carried out among 400 women 50 years and older in Sanandaj, Iran. Data was collected by the questionnaire including information on socio demographical variables and measuring social support level. Data was analyzed by SPSS16 software. Multiple logistic regression was used to determine the predictive power of demographic variables and dimensions of social support for repeat mammography. Women aged 50-55 years had three times odds of repeat mammography compared to women aged 56-60 years) OR, 3.02). Married women had greater odds of repeat mammography compared to single women (P women with higher social support was 0.93 times greater than the women with lower social support (OR, 0.93; 95 % CI, 0.91-0.95; P women are less likely repeat mammography than other Asian women. Identifying the associations between perceived social support and repeat mammography may offer detailed information to allow for future study and guide the development of interventions not only for Iranian women but also for similar cultural that received pay too little attention to date in the breast cancer literature.

  5. Topological characteristics of helical repeat proteins

    NARCIS (Netherlands)

    Groves, M R; Barford, D

    The recent elucidation of protein structures based upon repeating amino acid motifs, including the armadillo motif, the HEAT motif and tetratricopeptide repeats, reveals that they belong to the class of helical repeat proteins. These proteins share the common property of being assembled from tandem

  6. Involvement of Inflammation and Adverse Vascular Remodelling in the Blood Pressure Raising Effect of Repeatedly Heated Palm Oil in Rats

    Directory of Open Access Journals (Sweden)

    Chun-Yi Ng

    2012-01-01

    Full Text Available Oil thermoxidation during deep frying generates harmful oxidative free radicals that induce inflammation and increase the risk of hypertension. This study aimed to investigate the effect of repeatedly heated palm oil on blood pressure, aortic morphometry, and vascular cell adhesion molecule-1 (VCAM-1 expression in rats. Male Sprague-Dawley rats were divided into five groups: control, fresh palm oil (FPO, one-time-heated palm oil (1HPO, five-time-heated palm oil (5HPO, or ten-time-heated palm oil (10HPO. Feeding duration was six months. Blood pressure was measured at baseline and monthly using tail-cuff method. After six months, the rats were sacrificed and the aortic arches were dissected for morphometric and immunohistochemical analyses. FPO group showed significantly lower blood pressure than all other groups. Blood pressure was increased significantly in 5HPO and 10HPO groups. The aortae of 5HPO and 10HPO groups showed significantly increased thickness and area of intima-media, circumferential wall tension, and VCAM-1 than other groups. Elastic lamellae were disorganised and fragmented in 5HPO- and 10HPO-treated rats. VCAM-1 expression showed a significant positive correlation with blood pressure. In conclusion, prolonged consumption of repeatedly heated palm oil causes blood pressure elevation, adverse remodelling, and increased VCAM-1, which suggests a possible involvement of inflammation.

  7. Hazard Baseline Downgrade Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Blanchard, A.

    1998-01-01

    This Hazard Baseline Downgrade reviews the Effluent Treatment Facility, in accordance with Department of Energy Order 5480.23, WSRC11Q Facility Safety Document Manual, DOE-STD-1027-92, and DOE-EM-STD-5502-94. It provides a baseline grouping based on the chemical and radiological hazards associated with the facility. The Determination of the baseline grouping for ETF will aid in establishing the appropriate set of standards for the facility

  8. Validation of the Chinese SAD PERSONS Scale to predict repeated self-harm in emergency attendees in Taiwan.

    Science.gov (United States)

    Wu, Chia-Yi; Huang, Hui-Chun; Wu, Shu-I; Sun, Fang-Ju; Huang, Chiu-Ron; Liu, Shen-Ing

    2014-02-17

    Past and repeated self-harm are long-term risks to completed suicide. A brief rating scale to assess repetition risk of self-harm is important for high-risk identification and early interventions in suicide prevention. The study aimed to examine the validity of the Chinese SAD PERSONS Scale (CSPS) and to evaluate its feasibility in clinical settings. One hundred and forty-seven patients with self-harm were recruited from the Emergency Department and assessed at baseline and the sixth month. The controls, 284 people without self-harm from the Family Medicine Department in the same hospital were recruited and assessed concurrently. The psychometric properties of the CSPS were examined using baseline and follow-up measurements that assessed a variety of suicide risk factors. Clinical feasibility and applicability of the CSPS were further evaluated by a group of general nurses who used case vignette approach in CSPS risk assessment in clinical settings. An open-ended question inquiring their opinions of scale adaptation to hospital inpatient assessment for suicide risks were also analyzed using content analysis. The CSPS was significantly correlated with other scales measuring depression, hopelessness and suicide ideation. A cut-off point of the scale was at 4/5 in predicting 6-month self-harm repetition with the sensitivity and specificity being 65.4% and 58.1%, respectively. Based on the areas under the Receiver Operating Characteristic curves, the predictive validity of the scale showed a better performance than the other scales. Fifty-four nurses, evaluating the scale using case vignette found it a useful tool to raise the awareness of suicide risk and a considerable tool to be adopted into nursing care. The Chinese SAD PERSONS Scale is a brief instrument with acceptable psychometric properties for self-harm prediction. However, cautions should be paid to level of therapeutic relationships during assessment, staff workload and adequate training for wider clinical

  9. Charactering baseline shift with 4th polynomial function for portable biomedical near-infrared spectroscopy device

    Science.gov (United States)

    Zhao, Ke; Ji, Yaoyao; Pan, Boan; Li, Ting

    2018-02-01

    The continuous-wave Near-infrared spectroscopy (NIRS) devices have been highlighted for its clinical and health care applications in noninvasive hemodynamic measurements. The baseline shift of the deviation measurement attracts lots of attentions for its clinical importance. Nonetheless current published methods have low reliability or high variability. In this study, we found a perfect polynomial fitting function for baseline removal, using NIRS. Unlike previous studies on baseline correction for near-infrared spectroscopy evaluation of non-hemodynamic particles, we focused on baseline fitting and corresponding correction method for NIRS and found that the polynomial fitting function at 4th order is greater than the function at 2nd order reported in previous research. Through experimental tests of hemodynamic parameters of the solid phantom, we compared the fitting effect between the 4th order polynomial and the 2nd order polynomial, by recording and analyzing the R values and the SSE (the sum of squares due to error) values. The R values of the 4th order polynomial function fitting are all higher than 0.99, which are significantly higher than the corresponding ones of 2nd order, while the SSE values of the 4th order are significantly smaller than the corresponding ones of the 2nd order. By using the high-reliable and low-variable 4th order polynomial fitting function, we are able to remove the baseline online to obtain more accurate NIRS measurements.

  10. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    Science.gov (United States)

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Immediate Effects of a Single Session of Motor Skill Training on the Lumbar Movement Pattern During a Functional Activity in People With Low Back Pain: A Repeated-Measures Study.

    Science.gov (United States)

    Marich, Andrej V; Lanier, Vanessa M; Salsich, Gretchen B; Lang, Catherine E; Van Dillen, Linda R

    2018-04-06

    People with low back pain (LBP) may display an altered lumbar movement pattern of early lumbar motion compared to people with healthy backs. Modifying this movement pattern during a clinical test decreases pain. It is unknown whether similar effects would be seen during a functional activity. The objective of this study is was to examine the lumbar movement patterns before and after motor skill training, effects on pain, and characteristics that influenced the ability to modify movement patterns. The design consisted of a repeated-measures study examining early-phase lumbar excursion in people with LBP during a functional activity test. Twenty-six people with chronic LBP received motor skill training, and 16 people with healthy backs were recruited as a reference standard. Twenty minutes of motor skill training to decrease early-phase lumbar excursion during the performance of a functional activity were used as a treatment intervention. Early-phase lumbar excursion was measured before and after training. Participants verbally reported increased pain, decreased pain, or no change in pain during performance of the functional activity test movement in relation to their baseline pain. The characteristics of people with LBP that influenced the ability to decrease early-phase lumbar excursion were examined. People with LBP displayed greater early-phase lumbar excursion before training than people with healthy backs (LBP: mean = 11.2°, 95% CI = 9.3°-13.1°; healthy backs: mean = 7.1°, 95% CI = 5.8°-8.4°). Following training, the LBP group showed a decrease in the amount of early-phase lumbar excursion (mean change = 4.1°, 95% CI = 2.4°-5.8°); 91% of people with LBP reported that their pain decreased from baseline following training. The longer the duration of LBP (β = - 0.22) and the more early-phase lumbar excursion before training (β = - 0.82), the greater the change in early-phase lumbar excursion following training. The long

  12. Do leukocyte telomere length dynamics depend on baseline telomere length? An analysis that corrects for ‘regression to the mean’

    International Nuclear Information System (INIS)

    Verhulst, Simon; Aviv, Abraham; Benetos, Athanase; Berenson, Gerald S.; Kark, Jeremy D.

    2013-01-01

    Leukocyte telomere length (LTL) shortens with age. Longitudinal studies have reported accelerated LTL attrition when baseline LTL is longer. However, the dependency of LTL attrition on baseline LTL might stem from a statistical artifact known as regression to the mean (RTM). To our knowledge no published study of LTL dynamics (LTL and its attrition rate) has corrected for this phenomenon. We illustrate the RTM effect using replicate LTL measurements, and show, using simulated data, how the RTM effect increases with a rise in stochastic measurement variation (representing LTL measurement error), resulting in spurious increasingly elevated dependencies of attrition on baseline values. In addition, we re-analyzed longitudinal LTL data collected from four study populations to test the hypothesis that LTL attrition depends on baseline LTL. We observed that the rate of LTL attrition was proportional to baseline LTL, but correction for the RTM effect reduced the slope of the relationship by 57 % when measurement error was low (coefficient of variation ∼2 %). A modest but statistically significant effect remained however, indicating that high baseline LTL is associated with higher LTL attrition even when correcting for the RTM effect. Baseline LTL explained 1.3 % of the variation in LTL attrition, but this effect, which differed significantly between the study samples, appeared to be primarily attributable to the association in men (3.7 %)

  13. Repeatability, number of harvests, and phenotypic stability of dry matter yield and quality traits of Panicum maximum jacq.

    Directory of Open Access Journals (Sweden)

    Francisco Duarte Fernandes

    2017-04-01

    Full Text Available Selection of superior forage genotypes is based on agronomic traits assayed in repeated measures. The questions are how repeatable the performance of individual genotypes is and how many harvests are needed to select the best genotypes. The objectives were to estimate repeatability coefficients of dry matter yield (DMY and forage quality, their phenotypic stability and the number of harvests needed for an accurate selection. Two randomized complete block design experiments data with 24 genotypes each, undergoing 12 and 16 harvests, over a period of 2 and 3 years, respectively, were used. The DMY repeatability estimates ranged from 0.42 to 0.55, suggesting a low heritability. The mean numbers of repeated measures were 5 and 7 harvests for 0.80 and 0.85 accuracy, respectively. The inclusion of the first two harvests negatively affects the estimates. Repeatability for quality traits ranged from 0.30 to 0.69, indicating low to moderate heritability.

  14. Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes

    Science.gov (United States)

    Zavorsky, Gerald S.

    2010-01-01

    Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…

  15. Comparison of diet measures from a food-frequency questionnaire with measures from repeated 24-hour dietary recalls. The Norwegian Women and Cancer Study.

    Science.gov (United States)

    Hjartåker, Anette; Andersen, Lene Frost; Lund, Eiliv

    2007-10-01

    To compare diet measures from a food-frequency questionnaire (FFQ) with measures from 24-hour dietary recalls (24HDRs). The participants answered an FFQ after completing four, repeated 24HDRs during a year. Norway, nationwide. Of 500 women randomly selected from The Norwegian Women and Cancer Study (the Norwegian arm of the European Prospective Investigation into Cancer and Nutrition), 286 agreed to participate and 238 completed the study. On the group level, the FFQ overestimated absolute intake in seven and underestimated intake in six of 21 food groups. Intakes of energy, fat, added sugar and alcohol were lower in the FFQ than in the 24HDRs, whereas intake of fibre was higher. Spearman's rank correlation coefficient ranged from 0.13 (desserts) to 0.82 (coffee) for foods, and from 0.25 (beta-carotene) to 0.67 (alcohol) for nutrients. Three per cent of the observations on nutrient intake fell in the opposite quintile when classified according to the FFQ as compared with the 24HDR. The median calibration coefficient, calculated by regression of the 24HDR data on the FFQ data, was 0.57 for foods and 0.38 for nutrients. The FFQ's ability to rank subjects was good for foods eaten frequently and fairly good for macronutrients in terms of energy percentages. Weaker ranking abilities were seen for foods eaten infrequently and for some micronutrients. The results underline the necessity of performing measurement error corrections.

  16. Assessment of early treatment response to neoadjuvant chemotherapy in breast cancer using non-mono-exponential diffusion models: a feasibility study comparing the baseline and mid-treatment MRI examinations

    Energy Technology Data Exchange (ETDEWEB)

    Bedair, Reem; Manavaki, Roido; Gill, Andrew B.; Abeyakoon, Oshaani; Gilbert, Fiona J. [University of Cambridge, Department of Radiology, School of Clinical Medicine, Cambridge (United Kingdom); Priest, Andrew N.; Patterson, Andrew J. [Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Addenbrookes Hospital, Cambridge (United Kingdom); McLean, Mary A. [Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Addenbrookes Hospital, Cambridge (United Kingdom); University of Cambridge, Li Ka Shing Centre, Cancer Research UK Cambridge Institute, Cambridge (United Kingdom); Graves, Martin J. [University of Cambridge, Department of Radiology, School of Clinical Medicine, Cambridge (United Kingdom); Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Addenbrookes Hospital, Cambridge (United Kingdom); Griffiths, John R. [University of Cambridge, Li Ka Shing Centre, Cancer Research UK Cambridge Institute, Cambridge (United Kingdom)

    2017-07-15

    To assess the feasibility of the mono-exponential, bi-exponential and stretched-exponential models in evaluating response of breast tumours to neoadjuvant chemotherapy (NACT) at 3 T. Thirty-six female patients (median age 53, range 32-75 years) with invasive breast cancer undergoing NACT were enrolled for diffusion-weighted MRI (DW-MRI) prior to the start of treatment. For assessment of early response, changes in parameters were evaluated on mid-treatment MRI in 22 patients. DW-MRI was performed using eight b values (0, 30, 60, 90, 120, 300, 600, 900 s/mm{sup 2}). Apparent diffusion coefficient (ADC), tissue diffusion coefficient (D{sub t}), vascular fraction (Florin), distributed diffusion coefficient (DDC) and alpha (α) parameters were derived. Then t tests compared the baseline and changes in parameters between response groups. Repeatability was assessed at inter- and intraobserver levels. All patients underwent baseline MRI whereas 22 lesions were available at mid-treatment. At pretreatment, mean diffusion coefficients demonstrated significant differences between groups (p < 0.05). At mid-treatment, percentage increase in ADC and DDC showed significant differences between responders (49 % and 43 %) and non-responders (21 % and 32 %) (p = 0.03, p = 0.04). Overall, stretched-exponential parameters showed excellent repeatability. DW-MRI is sensitive to baseline and early treatment changes in breast cancer using non-mono-exponential models, and the stretched-exponential model can potentially monitor such changes. (orig.)

  17. Assessment of early treatment response to neoadjuvant chemotherapy in breast cancer using non-mono-exponential diffusion models: a feasibility study comparing the baseline and mid-treatment MRI examinations

    International Nuclear Information System (INIS)

    Bedair, Reem; Manavaki, Roido; Gill, Andrew B.; Abeyakoon, Oshaani; Gilbert, Fiona J.; Priest, Andrew N.; Patterson, Andrew J.; McLean, Mary A.; Graves, Martin J.; Griffiths, John R.

    2017-01-01

    To assess the feasibility of the mono-exponential, bi-exponential and stretched-exponential models in evaluating response of breast tumours to neoadjuvant chemotherapy (NACT) at 3 T. Thirty-six female patients (median age 53, range 32-75 years) with invasive breast cancer undergoing NACT were enrolled for diffusion-weighted MRI (DW-MRI) prior to the start of treatment. For assessment of early response, changes in parameters were evaluated on mid-treatment MRI in 22 patients. DW-MRI was performed using eight b values (0, 30, 60, 90, 120, 300, 600, 900 s/mm"2). Apparent diffusion coefficient (ADC), tissue diffusion coefficient (D_t), vascular fraction (Florin), distributed diffusion coefficient (DDC) and alpha (α) parameters were derived. Then t tests compared the baseline and changes in parameters between response groups. Repeatability was assessed at inter- and intraobserver levels. All patients underwent baseline MRI whereas 22 lesions were available at mid-treatment. At pretreatment, mean diffusion coefficients demonstrated significant differences between groups (p < 0.05). At mid-treatment, percentage increase in ADC and DDC showed significant differences between responders (49 % and 43 %) and non-responders (21 % and 32 %) (p = 0.03, p = 0.04). Overall, stretched-exponential parameters showed excellent repeatability. DW-MRI is sensitive to baseline and early treatment changes in breast cancer using non-mono-exponential models, and the stretched-exponential model can potentially monitor such changes. (orig.)

  18. Environmental baselines: preparing for shale gas in the UK

    Science.gov (United States)

    Bloomfield, John; Manamsa, Katya; Bell, Rachel; Darling, George; Dochartaigh, Brighid O.; Stuart, Marianne; Ward, Rob

    2014-05-01

    Groundwater is a vital source of freshwater in the UK. It provides almost 30% of public water supply on average, but locally, for example in south-east England, it is constitutes nearly 90% of public supply. In addition to public supply, groundwater has a number of other uses including agriculture, industry, and food and drink production. It is also vital for maintaining river flows especially during dry periods and so is essential for maintaining ecosystem health. Recently, there have been concerns expressed about the potential impacts of shale gas development on groundwater. The UK has abundant shales and clays which are currently the focus of considerable interest and there is active research into their characterisation, resource evaluation and exploitation risks. The British Geological Survey (BGS) is undertaking research to provide information to address some of the environmental concerns related to the potential impacts of shale gas development on groundwater resources and quality. The aim of much of this initial work is to establish environmental baselines, such as a baseline survey of methane occurrence in groundwater (National methane baseline study) and the spatial relationships between potential sources and groundwater receptors (iHydrogeology project), prior to any shale gas exploration and development. The poster describes these two baseline studies and presents preliminary findings. BGS are currently undertaking a national survey of baseline methane concentrations in groundwater across the UK. This work will enable any potential future changes in methane in groundwater associated with shale gas development to be assessed. Measurements of methane in potable water from the Cretaceous, Jurassic and Triassic carbonate and sandstone aquifers are variable and reveal methane concentrations of up to 500 micrograms per litre, but the mean value is relatively low at documented in the range 2km. The geological modelling process will be presented and discussed

  19. Repeated intravenous doxapram induces phrenic motor facilitation.

    Science.gov (United States)

    Sandhu, M S; Lee, K Z; Gonzalez-Rothi, E J; Fuller, D D

    2013-12-01

    Doxapram is a respiratory stimulant used to treat hypoventilation. Here we investigated whether doxapram could also trigger respiratory neuroplasticity. Specifically, we hypothesized that intermittent delivery of doxapram at low doses would lead to long-lasting increases (i.e., facilitation) of phrenic motor output in anesthetized, vagotomized, and mechanically-ventilated rats. Doxapram was delivered intravenously in a single bolus (2 or 6mg/kg) or as a series of 3 injections (2mg/kg) at 5min intervals. Control groups received pH-matched saline injections (vehicle) or no treatment (anesthesia time control). Doxapram evoked an immediate increase in phrenic output in all groups, but a persistent increase in burst amplitude only occurred after repeated dosing with 2mg/kg. At 60min following the last injection, phrenic burst amplitude was 168±24% of baseline (%BL) in the group receiving 3 injections (Pphrenic response to doxapram (2mg/kg) was reduced by 68% suggesting that at low doses the drug was acting primarily via the carotid chemoreceptors. We conclude that intermittent application of doxapram can trigger phrenic neuroplasticity, and this approach might be of use in the context of respiratory rehabilitation following neurologic injury. © 2013.

  20. The neuropsychology of repeated 1- and 3-meter springboard diving among college athletes.

    Science.gov (United States)

    Zillmer, Eric A

    2003-01-01

    This study examined the neuropsychological effects of repeated springboard diving. It was hypothesized that the impact velocity, which can range from 20 to 30 mph, and accompanying deceleration in the water may lead to concussions and affect the diver's cognitive function. Six varsity National Collegiate Athletic Association Division 1 springboard divers participated in the study. Each diver performed a total of 50 practice dives from either the 1- or 3-m springboard. After each set of 10 dives, the participants were immediately evaluated at poolside using the Symbol Digit Modalities Test, the Stroop Color Word Test, and the Trail Making Test B. Baseline testing revealed, consistent with their athletic specialty, clear neurocognitive strengths among the divers on tests sensitive to proprioception, motor speed, and visual-spatial organization. Results from the serial assessments indicated no detectable neuropsychological deficits among competitive divers compared to baseline testing. Skilled diving at the collegiate level appears to be a safe sport and water appears to present the perfect medium for gradual deceleration. More studies, however, are warranted for 5-, 7.5-, and 10-m platform diving since the impact velocity of the diver from these heights is higher.

  1. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  2. A novel type of very long baseline astronomical intensity interferometer

    Science.gov (United States)

    Borra, Ermanno F.

    2013-12-01

    This article presents a novel type of very long baseline astronomical interferometer that uses the fluctuations, as a function of time, of the intensity measured by a quadratic detector, which is a common type of astronomical detector. The theory on which the technique is based is validated by laboratory experiments. Its outstanding principal advantages comes from the fact that the angular structure of an astronomical object is simply determined from the visibility of the minima of the spectrum of the intensity fluctuations measured by the detector, as a function of the frequency of the fluctuations, while keeping the spacing between mirrors constant. This would allow a simple setup capable of high angular resolutions because it could use an extremely large baseline. Another major interest is that it allows for a more efficient use of telescope time because observations at a single baseline are sufficient, while amplitude and intensity interferometers need several observations at different baselines. The fact that one does not have to move the telescopes would also allow detecting faster time variations because having to move the telescopes sets a lower limit to the time variations that can be detected. The technique uses wave interaction effects and thus has some characteristics in common with intensity interferometry. A disadvantage of the technique, like in intensity interferometry, is that it needs strong sources if observing at high frequencies (e.g. the visible). This is a minor disadvantage in the radio region. At high frequencies, this disadvantage is mitigated by the fact that, like in intensity interferometry, the requirements of the optical quality of the mirrors used are far less severe than in amplitude interferometry so that poor quality large reflectors (e.g. Cherenkov telescopes) can be used in the optical region.

  3. Unusual structures are present in DNA fragments containing super-long Huntingtin CAG repeats.

    Directory of Open Access Journals (Sweden)

    Daniel Duzdevich

    2011-02-01

    Full Text Available In the R6/2 mouse model of Huntington's disease (HD, expansion of the CAG trinucleotide repeat length beyond about 300 repeats induces a novel phenotype associated with a reduction in transcription of the transgene.We analysed the structure of polymerase chain reaction (PCR-generated DNA containing up to 585 CAG repeats using atomic force microscopy (AFM. As the number of CAG repeats increased, an increasing proportion of the DNA molecules exhibited unusual structural features, including convolutions and multiple protrusions. At least some of these features are hairpin loops, as judged by cross-sectional analysis and sensitivity to cleavage by mung bean nuclease. Single-molecule force measurements showed that the convoluted DNA was very resistant to untangling. In vitro replication by PCR was markedly reduced, and TseI restriction enzyme digestion was also hindered by the abnormal DNA structures. However, significantly, the DNA gained sensitivity to cleavage by the Type III restriction-modification enzyme, EcoP15I."Super-long" CAG repeats are found in a number of neurological diseases and may also appear through CAG repeat instability. We suggest that unusual DNA structures associated with super-long CAG repeats decrease transcriptional efficiency in vitro. We also raise the possibility that if these structures occur in vivo, they may play a role in the aetiology of CAG repeat diseases such as HD.

  4. Baseline Body Mass Index and the Efficacy of Hypoglycemic Treatment in Type 2 Diabetes: A Meta-Analysis

    Science.gov (United States)

    Cai, Xiaoling; Yang, Wenjia; Gao, Xueying; Zhou, Lingli; Han, Xueyao; Ji, Linong

    2016-01-01

    Aim The aim of this study is to compare the effects of hypoglycemic treatments in groups of patients categorized according to the mean baseline body mass indexes (BMIs). Methods Studies were identified by a literature search and all the studies were double blind, placebo-controlled randomized trials in type 2 diabetes patients; study length of ≥12 weeks with the efficacy evaluated by changes in HbA1c from baseline in groups. The electronic search was first conducted in January 2015 and repeated in June 2015. Results 227 studies were included. Treatment with sulfonylureas was compared with placebo in overweight patients and resulted in a significantly greater change in the HbA1c levels (weighted mean difference (WMD), −1.39%) compared to obese patients (WMD, −0.77%)(p0.05). Treatment with alpha glucosidase inhibitors in normal weight patients was associated with a HbA1c change (WMD, −0.94%) that was comparable that in overweight (WMD, −0.72%) and obese patients (WMD, −0.56%)(p>0.05). Treatment with thiazolidinediones in normal weight patients was associated with a HbA1c change (WMD, −1.04%) that was comparable with that in overweight (WMD, −1.02%) and obese patients (WMD, −0.88%)(p>0.05). Treatment with DPP-4 inhibitors in normal weight patients was associated with a HbA1c change (WMD, −0.93%) that was comparable with that in overweight (WMD, −0.66%) and obese patients (WMD, −0.61%)(p>0.05). In total, of the seven hypoglycemic agents, regression analysis indicated that the mean baseline BMI was not associated with the mean HbA1c changes from baseline. Conclusion In each kind of hypoglycemic therapy in type 2 diabetes, the baseline BMI was not associated with the efficacy of HbA1c changes from baseline. PMID:27935975

  5. Baseline frontostriatal-limbic connectivity predicts reward-based memory formation.

    Science.gov (United States)

    Hamann, Janne M; Dayan, Eran; Hummel, Friedhelm C; Cohen, Leonardo G

    2014-12-01

    Reward mediates the acquisition and long-term retention of procedural skills in humans. Yet, learning under rewarded conditions is highly variable across individuals and the mechanisms that determine interindividual variability in rewarded learning are not known. We postulated that baseline functional connectivity in a large-scale frontostriatal-limbic network could predict subsequent interindividual variability in rewarded learning. Resting-state functional MRI was acquired in two groups of subjects (n = 30) who then trained on a visuomotor procedural learning task with or without reward feedback. We then tested whether baseline functional connectivity within the frontostriatal-limbic network predicted memory strength measured immediately, 24 h and 1 month after training in both groups. We found that connectivity in the frontostriatal-limbic network predicted interindividual variability in the rewarded but not in the unrewarded learning group. Prediction was strongest for long-term memory. Similar links between connectivity and reward-based memory were absent in two control networks, a fronto-parieto-temporal language network and the dorsal attention network. The results indicate that baseline functional connectivity within the frontostriatal-limbic network successfully predicts long-term retention of rewarded learning. © 2014 Wiley Periodicals, Inc.

  6. Localizing gravitational wave sources with single-baseline atom interferometers

    Science.gov (United States)

    Graham, Peter W.; Jung, Sunghoon

    2018-02-01

    Localizing sources on the sky is crucial for realizing the full potential of gravitational waves for astronomy, astrophysics, and cosmology. We show that the midfrequency band, roughly 0.03 to 10 Hz, has significant potential for angular localization. The angular location is measured through the changing Doppler shift as the detector orbits the Sun. This band maximizes the effect since these are the highest frequencies in which sources live for several months. Atom interferometer detectors can observe in the midfrequency band, and even with just a single baseline they can exploit this effect for sensitive angular localization. The single-baseline orbits around the Earth and the Sun, causing it to reorient and change position significantly during the lifetime of the source, and making it similar to having multiple baselines/detectors. For example, atomic detectors could predict the location of upcoming black hole or neutron star merger events with sufficient accuracy to allow optical and other electromagnetic telescopes to observe these events simultaneously. Thus, midband atomic detectors are complementary to other gravitational wave detectors and will help complete the observation of a broad range of the gravitational spectrum.

  7. The prognostic utility of baseline alpha-fetoprotein for hepatocellular carcinoma patients.

    Science.gov (United States)

    Silva, Jack P; Gorman, Richard A; Berger, Nicholas G; Tsai, Susan; Christians, Kathleen K; Clarke, Callisia N; Mogal, Harveshp; Gamblin, T Clark

    2017-12-01

    Alpha-fetoprotein (AFP) has a valuable role in postoperative surveillance for hepatocellular carcinoma (HCC) recurrence. The utility of pretreatment or baseline AFP remains controversial. The present study hypothesized that elevated baseline AFP levels are associated with worse overall survival in HCC patients. Adult HCC patients were identified using the National Cancer Database (2004-2013). Patients were stratified according to baseline AFP measurements into the following groups: Negative (2000). The primary outcome was overall survival (OS), which was analyzed by log-rank test and graphed using Kaplan-Meier method. Multivariate regression modeling was used to determine hazard ratios (HR) for OS. Of 41 107 patients identified, 15 809 (33.6%) were Negative. Median overall survival was highest in the Negative group, followed by Borderline, Elevated, and Highly Elevated (28.7 vs 18.9 vs 8.8 vs 3.2 months; P < 0.001). On multivariate analysis, overall survival hazard ratios for the Borderline, Elevated, and Highly Elevated groups were 1.18 (P = 0.267), 1.94 (P < 0.001), and 1.77 (P = 0.007), respectively (reference Negative). Baseline AFP independently predicted overall survival in HCC patients regardless of treatment plan. A baseline AFP value is a simple and effective method to assist in expected survival for HCC patients. © 2017 Wiley Periodicals, Inc.

  8. Combined effects of repeated oral hygiene motivation and type of toothbrush on orthodontic patients: a blind randomized clinical trial.

    Science.gov (United States)

    Marini, Ida; Bortolotti, Francesco; Parenti, Serena Incerti; Gatto, Maria Rosaria; Bonetti, Giulio Alessandri

    2014-09-01

    To investigate the effects on plaque index (PI) scores of manual or electric toothbrush with or without repeated oral hygiene instructions (OHI) and motivation on patients wearing fixed orthodontic appliances. One month after the orthodontic fixed appliance bonding on both arches, 60 patients were randomly assigned to four groups; groups E1 (n  =  15) and E2 (n  =  15) received a powered rotating-oscillating toothbrush, and groups M1 (n  =  15) and M2 (n  =  15) received a manual toothbrush. Groups E1 and M1 received OHI and motivation at baseline (T0) and after 4, 8, 12, 16, and 20 weeks (T4, T8, T12, T16, and T20, respectively) by a Registered Dental Hygienist; groups E2 and M2 received OHI and motivation only at baseline. At each time point a blinded examiner scored plaque of all teeth using the modified Quigley-Hein PI. In all groups the PI score decreased significantly over time, and there were differences among groups at T8, T12, T16, and T20. At T8, PI scores of group E1 were lower than those of group E2, and at T12, T16, and T20, PI scores of groups M1 and E1 were lower compared to those of groups M2 and E2. A linear mixed model showed that the effect of repeated OHI and motivation during time was statistically significant, independently from the use of manual or electric toothbrush. The present results showed that repeated OHI and motivation are crucial in reducing PI score in orthodontic patients, independent of the type of toothbrush used.

  9. 10 CFR 850.20 - Baseline beryllium inventory.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Baseline beryllium inventory. 850.20 Section 850.20 Energy... Baseline beryllium inventory. (a) The responsible employer must develop a baseline inventory of the... inventory, the responsible employer must: (1) Review current and historical records; (2) Interview workers...

  10. 40 CFR 80.92 - Baseline auditor requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Baseline auditor requirements. 80.92... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Anti-Dumping § 80.92 Baseline auditor requirements. (a... determination methodology, resulting baseline fuel parameter, volume and emissions values verified by an auditor...

  11. Repeating Marx

    DEFF Research Database (Denmark)

    Fuchs, Christian; Monticelli, Lara

    2018-01-01

    This introduction sets out the context of the special issue “Karl Marx @ 200: Debating Capitalism & Perspectives for the Future of Radical Theory”, which was published on the occasion of Marx’s bicentenary on 5 May 2018. First, we give a brief overview of contemporary capitalism’s development...... and its crises. Second, we argue that it is important to repeat Marx today. Third, we reflect on lessons learned from 200 years of struggles for alternatives to capitalism. Fourth, we give an overview of the contributions in this special issue. Taken together, the contributions in this special issue show...... that Marx’s theory and politics remain key inspirations for understanding exploitation and domination in 21st-century society and for struggles that aim to overcome these phenomena and establishing a just and fair society. We need to repeat Marx today....

  12. Physics with a very long neutrino factory baseline

    International Nuclear Information System (INIS)

    Gandhi, Raj; Winter, Walter

    2007-01-01

    We discuss the neutrino oscillation physics of a very long neutrino factory baseline over a broad range of lengths (between 6000 km and 9000 km), centered on the 'magic baseline' (∼7500 km) where correlations with the leptonic CP phase are suppressed by matter effects. Since the magic baseline depends only on the density, we study the impact of matter density profile effects and density uncertainties over this range, and the impact of detector locations off the optimal baseline. We find that the optimal constant density describing the physics over this entire baseline range is about 5% higher than the average matter density. This implies that the magic baseline is significantly shorter than previously inferred. However, while a single detector optimization requires fine-tuning of the (very long) baseline length, its combination with a near detector at a shorter baseline is much less sensitive to the far detector location and to uncertainties in the matter density. In addition, we point out different applications of this baseline which go beyond its excellent correlation and degeneracy resolution potential. We demonstrate that such a long baseline assists in the improvement of the θ 13 precision and in the resolution of the octant degeneracy. Moreover, we show that the neutrino data from such a baseline could be used to extract the matter density along the profile up to 0.24% at 1σ for large sin 2 2θ 13 , providing a useful discriminator between different geophysical models

  13. Terrestrial gamma radiation baseline mapping using ultra low density sampling methods

    International Nuclear Information System (INIS)

    Kleinschmidt, R.; Watson, D.

    2016-01-01

    Baseline terrestrial gamma radiation maps are indispensable for providing basic reference information that may be used in assessing the impact of a radiation related incident, performing epidemiological studies, remediating land contaminated with radioactive materials, assessment of land use applications and resource prospectivity. For a large land mass, such as Queensland, Australia (over 1.7 million km 2 ), it is prohibitively expensive and practically difficult to undertake detailed in-situ radiometric surveys of this scale. It is proposed that an existing, ultra-low density sampling program already undertaken for the purpose of a nationwide soil survey project be utilised to develop a baseline terrestrial gamma radiation map. Geoelement data derived from the National Geochemistry Survey of Australia (NGSA) was used to construct a baseline terrestrial gamma air kerma rate map, delineated by major drainage catchments, for Queensland. Three drainage catchments (sampled at the catchment outlet) spanning low, medium and high radioelement concentrations were selected for validation of the methodology using radiometric techniques including in-situ measurements and soil sampling for high resolution gamma spectrometry, and comparative non-radiometric analysis. A Queensland mean terrestrial air kerma rate, as calculated from the NGSA outlet sediment uranium, thorium and potassium concentrations, of 49 ± 69 nGy h −1 (n = 311, 3σ 99% confidence level) is proposed as being suitable for use as a generic terrestrial air kerma rate background range. Validation results indicate that catchment outlet measurements are representative of the range of results obtained across the catchment and that the NGSA geoelement data is suitable for calculation and mapping of terrestrial air kerma rate. - Highlights: • A baseline terrestrial air kerma map of Queensland, Australia was developed using geochemical data from a major drainage catchment ultra-low density sampling program

  14. Acceptability and feasibility of repeated mucosal specimen collection in clinical trial participants in Kenya.

    Directory of Open Access Journals (Sweden)

    Gloria Omosa-Manyonyi

    Full Text Available Mucosal specimens are essential to evaluate compartmentalized immune responses to HIV vaccine candidates and other mucosally targeted investigational products. We studied the acceptability and feasibility of repeated mucosal sampling in East African clinical trial participants at low risk of HIV and other sexually transmitted infections.The Kenya AIDS Vaccine Initiative (KAVI enrolled participants into three Phase 1 trials of preventive HIV candidate vaccines in 2011-2012 at two clinical research centers in Nairobi. After informed consent to a mucosal sub-study, participants were asked to undergo collection of mucosal secretions (saliva, oral fluids, semen, cervico-vaginal and rectal, but could opt out of any collection at any visit. Specimens were collected at baseline and two additional time points. A tolerability questionnaire was administered at the final sub-study visit. Of 105 trial participants, 27 of 34 women (79% and 62 of 71 men (87% enrolled in the mucosal sub-study. Nearly all sub-study participants gave saliva and oral fluids at all visits. Semen was collected from about half the participating men (47-48% at all visits. Cervico-vaginal secretions were collected by Softcup from about two thirds of women (63% at baseline, increasing to 78% at the following visits, with similar numbers for cervical secretion collection by Merocel sponge; about half of women (52% gave cervico-vaginal samples at all visits. Rectal secretions were collected with Merocel sponge from about a quarter of both men and women (24% at all 3 visits, with 16% of men and 19% of women giving rectal samples at all visits.Repeated mucosal sampling in clinical trial participants in Kenya is feasible, with a good proportion of participants consenting to most sampling methods with the exception of rectal samples. Experienced staff members of both sexes and trained counselors with standardized messaging may improve acceptance of rectal sampling.

  15. Baseline Plasma C-Reactive Protein Concentrations and Motor Prognosis in Parkinson Disease.

    Directory of Open Access Journals (Sweden)

    Atsushi Umemura

    Full Text Available C-reactive protein (CRP, a blood inflammatory biomarker, is associated with the development of Alzheimer disease. In animal models of Parkinson disease (PD, systemic inflammatory stimuli can promote neuroinflammation and accelerate dopaminergic neurodegeneration. However, the association between long-term systemic inflammations and neurodegeneration has not been assessed in PD patients.To investigate the longitudinal effects of baseline CRP concentrations on motor prognosis in PD.Retrospective analysis of 375 patients (mean age, 69.3 years; mean PD duration, 6.6 years. Plasma concentrations of high-sensitivity CRP were measured in the absence of infections, and the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III scores were measured at five follow-up intervals (Days 1-90, 91-270, 271-450, 451-630, and 631-900.Change of UPDRS-III scores from baseline to each of the five follow-up periods.Change in UPDRS-III scores was significantly greater in PD patients with CRP concentrations ≥0.7 mg/L than in those with CRP concentrations <0.7 mg/L, as determined by a generalized estimation equation model (P = 0.021 for the entire follow-up period and by a generalized regression model (P = 0.030 for the last follow-up interval (Days 631-900. The regression coefficients of baseline CRP for the two periods were 1.41 (95% confidence interval [CI] 0.21-2.61 and 2.62 (95% CI 0.25-4.98, respectively, after adjusting for sex, age, baseline UPDRS-III score, dementia, and incremental L-dopa equivalent dose.Baseline plasma CRP levels were associated with motor deterioration and predicted motor prognosis in patients with PD. These associations were independent of sex, age, PD severity, dementia, and anti-Parkinsonian agents, suggesting that subclinical systemic inflammations could accelerate neurodegeneration in PD.

  16. Robust extraction of baseline signal of atmospheric trace species using local regression

    Science.gov (United States)

    Ruckstuhl, A. F.; Henne, S.; Reimann, S.; Steinbacher, M.; Vollmer, M. K.; O'Doherty, S.; Buchmann, B.; Hueglin, C.

    2012-11-01

    The identification of atmospheric trace species measurements that are representative of well-mixed background air masses is required for monitoring atmospheric composition change at background sites. We present a statistical method based on robust local regression that is well suited for the selection of background measurements and the estimation of associated baseline curves. The bootstrap technique is applied to calculate the uncertainty in the resulting baseline curve. The non-parametric nature of the proposed approach makes it a very flexible data filtering method. Application to carbon monoxide (CO) measured from 1996 to 2009 at the high-alpine site Jungfraujoch (Switzerland, 3580 m a.s.l.), and to measurements of 1,1-difluoroethane (HFC-152a) from Jungfraujoch (2000 to 2009) and Mace Head (Ireland, 1995 to 2009) demonstrates the feasibility and usefulness of the proposed approach. The determined average annual change of CO at Jungfraujoch for the 1996 to 2009 period as estimated from filtered annual mean CO concentrations is -2.2 ± 1.1 ppb yr-1. For comparison, the linear trend of unfiltered CO measurements at Jungfraujoch for this time period is -2.9 ± 1.3 ppb yr-1.

  17. Repeat immigration: A previously unobserved source of heterogeneity?

    Science.gov (United States)

    Aradhya, Siddartha; Scott, Kirk; Smith, Christopher D

    2017-07-01

    Register data allow for nuanced analyses of heterogeneities between sub-groups which are not observable in other data sources. One heterogeneity for which register data is particularly useful is in identifying unique migration histories of immigrant populations, a group of interest across disciplines. Years since migration is a commonly used measure of integration in studies seeking to understand the outcomes of immigrants. This study constructs detailed migration histories to test whether misclassified migrations may mask important heterogeneities. In doing so, we identify a previously understudied group of migrants called repeat immigrants, and show that they differ systematically from permanent immigrants. In addition, we quantify the degree to which migration information is misreported in the registers. The analysis is carried out in two steps. First, we estimate income trajectories for repeat immigrants and permanent immigrants to understand the degree to which they differ. Second, we test data validity by cross-referencing migration information with changes in income to determine whether there are inconsistencies indicating misreporting. From the first part of the analysis, the results indicate that repeat immigrants systematically differ from permanent immigrants in terms of income trajectories. Furthermore, income trajectories differ based on the way in which years since migration is calculated. The second part of the analysis suggests that misreported migration events, while present, are negligible. Repeat immigrants differ in terms of income trajectories, and may differ in terms of other outcomes as well. Furthermore, this study underlines that Swedish registers provide a reliable data source to analyze groups which are unidentifiable in other data sources.

  18. A repeat-until-success quantum computing scheme

    Energy Technology Data Exchange (ETDEWEB)

    Beige, A [School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT (United Kingdom); Lim, Y L [DSO National Laboratories, 20 Science Park Drive, Singapore 118230, Singapore (Singapore); Kwek, L C [Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542, Singapore (Singapore)

    2007-06-15

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes.

  19. A repeat-until-success quantum computing scheme

    International Nuclear Information System (INIS)

    Beige, A; Lim, Y L; Kwek, L C

    2007-01-01

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes

  20. Readout Distance Enhancement of the Passive Wireless Multi-Parameter Sensing System Using a Repeater Coil

    Directory of Open Access Journals (Sweden)

    Lifeng Wang

    2018-01-01

    Full Text Available A repeater coil is used to extend the detection distance of a passive wireless multi-parameter sensing system. The passive wireless sensing system has the ability of simultaneously monitoring three parameters by using backscatter modulation together with channel multiplexing. Two different repeater coils are designed and fabricated for readout distance enhancement of the sensing system: one is a PCB (printed circuit board repeater coil, and the other is a copper wire repeater coil. Under the conditions of fixed voltage and adjustable voltage, the maximum readout distance of the sensing system with and without a repeater coil is measured. Experimental results show that larger power supply voltage can help further increase the readout distance. The maximum readout distance of the sensing system with a PCB repeater coil has been extended 2.3 times, and the one with a copper wire repeater coil has been extended 3 times. Theoretical analysis and experimental results both indicate that the high Q factor repeater coil can extend the readout distance more. With the copper wire repeater coil as well as a higher power supply voltage, the passive wireless multi-parameter sensing system finally achieves a maximum readout distance of 13.5 cm.

  1. Comparison of serum leptin, glucose, total cholesterol and total protein levels in fertile and repeat breeder cows

    Directory of Open Access Journals (Sweden)

    Saime Guzel

    2014-12-01

    Full Text Available In the present study we measured serum glucose, leptin, total cholesterol and total protein concentrations in repeat breeder cows and compared them with fertile cows. For this aim, 20 repeat breeder cows and 20 fertile cows were used as material. Repeat breeder cows were found to have lower levels of leptin and glucose as compared with fertile ones. No significant differences in total cholesterol and total protein levels were observed between the two groups. No significant correlation of leptin with glucose, total cholesterol and total protein was observed in fertile and repeat breeder cows. Low concentrations of glucose and leptin can have some effects on reproductive problems as repeat breeder and help to understand potential mechanisms impairing fertility in repeat breeder cows.

  2. Analysis of a kinetic multi-segment foot model. Part I: Model repeatability and kinematic validity.

    Science.gov (United States)

    Bruening, Dustin A; Cooney, Kevin M; Buczek, Frank L

    2012-04-01

    Kinematic multi-segment foot models are still evolving, but have seen increased use in clinical and research settings. The addition of kinetics may increase knowledge of foot and ankle function as well as influence multi-segment foot model evolution; however, previous kinetic models are too complex for clinical use. In this study we present a three-segment kinetic foot model and thorough evaluation of model performance during normal gait. In this first of two companion papers, model reference frames and joint centers are analyzed for repeatability, joint translations are measured, segment rigidity characterized, and sample joint angles presented. Within-tester and between-tester repeatability were first assessed using 10 healthy pediatric participants, while kinematic parameters were subsequently measured on 17 additional healthy pediatric participants. Repeatability errors were generally low for all sagittal plane measures as well as transverse plane Hindfoot and Forefoot segments (median<3°), while the least repeatable orientations were the Hindfoot coronal plane and Hallux transverse plane. Joint translations were generally less than 2mm in any one direction, while segment rigidity analysis suggested rigid body behavior for the Shank and Hindfoot, with the Forefoot violating the rigid body assumptions in terminal stance/pre-swing. Joint excursions were consistent with previously published studies. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation.

    Science.gov (United States)

    Bogh, Morten K B; Schmedes, Anne V; Philipsen, Peter A; Thieden, Elisabeth; Wulf, Hans C

    2010-02-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol was measured at baseline. The increase in 25(OH)D level after UVB exposure was negatively correlated with baseline 25(OH)D level (Ppigmentation. In addition, we paired a dark-skinned group with a fair-skinned group according to baseline 25(OH)D levels and found no differences in 25(OH)D increase after identical UVB exposure.

  4. Large-baseline InSAR for precise topographic mapping: a framework for TanDEM-X large-baseline data

    Directory of Open Access Journals (Sweden)

    M. Pinheiro

    2017-09-01

    Full Text Available The global Digital Elevation Model (DEM resulting from the TanDEM-X mission provides information about the world topography with outstanding precision. In fact, performance analysis carried out with the already available data have shown that the global product is well within the requirements of 10 m absolute vertical accuracy and 2 m relative vertical accuracy for flat to moderate terrain. The mission's science phase took place from October 2014 to December 2015. During this phase, bistatic acquisitions with across-track separation between the two satellites up to 3.6 km at the equator were commanded. Since the relative vertical accuracy of InSAR derived elevation models is, in principle, inversely proportional to the system baseline, the TanDEM-X science phase opened the doors for the generation of elevation models with improved quality with respect to the standard product. However, the interferometric processing of the large-baseline data is troublesome due to the increased volume decorrelation and very high frequency of the phase variations. Hence, in order to fully profit from the increased baseline, sophisticated algorithms for the interferometric processing, and, in particular, for the phase unwrapping have to be considered. This paper proposes a novel dual-baseline region-growing framework for the phase unwrapping of the large-baseline interferograms. Results from two experiments with data from the TanDEM-X science phase are discussed, corroborating the expected increased level of detail of the large-baseline DEMs.

  5. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

    Directory of Open Access Journals (Sweden)

    Sha-Sha Yu

    2017-11-01

    Full Text Available AIM: To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL-Master and LenstarLS900 (Lenstar in measuring corneal parameters among cataract patients. METHODS: Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf, the steepest meridian power (Ks, mean power (Km, J0 and J45 were recorded. Intra-class correlation coefficients (ICCs, the coefficient of variance (COV, within subject standard deviation (Sw, and test-retest repeatability (2.77Sw were adopted to determine the repeatability. The 95% limit of agreement (95%LOA and Bland-Altman plots were used to assess comparability. RESULTS: Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION: Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.

  6. Effect of Enamel Caries Lesion Baseline Severity on Fluoride Dose-Response

    Directory of Open Access Journals (Sweden)

    Frank Lippert

    2017-01-01

    Full Text Available This study aimed to investigate the effect of enamel caries lesion baseline severity on fluoride dose-response under pH cycling conditions. Early caries lesions were created in human enamel specimens at four different severities (8, 16, 24, and 36 h. Lesions were allocated to treatment groups (0, 83, and 367 ppm fluoride as sodium fluoride based on Vickers surface microhardness (VHN and pH cycled for 5 d. The cycling model comprised 3 × 1 min fluoride treatments sandwiched between 2 × 60 min demineralization challenges with specimens stored in artificial saliva in between. VHN was measured again and changes versus lesion baseline were calculated (ΔVHN. Data were analyzed using two-way ANOVA (p<0.05. Increased demineralization times led to increased surface softening. The lesion severity×fluoride concentration interaction was significant (p<0.001. Fluoride dose-response was observed in all groups. Lesions initially demineralized for 16 and 8 h showed similar overall rehardening (ΔVHN and more than 24 and 36 h lesions, which were similar. The 8 h lesions showed the greatest fluoride response differential (367 versus 0 ppm F which diminished with increasing lesion baseline severity. The extent of rehardening as a result of the 0 ppm F treatment increased with increasing lesion baseline severity, whereas it decreased for the fluoride treatments. In conclusion, lesion baseline severity impacts the extent of the fluoride dose-response.

  7. Baseline Hemodynamics and Response to Contrast Media During Diagnostic Cardiac Catheterization Predict Adverse Events in Heart Failure Patients.

    Science.gov (United States)

    Denardo, Scott J; Vock, David M; Schmalfuss, Carsten M; Young, Gregory D; Tcheng, James E; O'Connor, Christopher M

    2016-07-01

    Contrast media administered during cardiac catheterization can affect hemodynamic variables. However, little is documented about the effects of contrast on hemodynamics in heart failure patients or the prognostic value of baseline and changes in hemodynamics for predicting subsequent adverse events. In this prospective study of 150 heart failure patients, we measured hemodynamics at baseline and after administration of iodixanol or iopamidol contrast. One-year Kaplan-Meier estimates of adverse event-free survival (death, heart failure hospitalization, and rehospitalization) were generated, grouping patients by baseline measures of pulmonary capillary wedge pressure (PCWP) and cardiac index (CI), and by changes in those measures after contrast administration. We used Cox proportional hazards modeling to assess sequentially adding baseline PCWP and change in CI to 5 validated risk models (Seattle Heart Failure Score, ESCAPE [Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness], CHARM [Candesartan in Heart Failure: Assessment of Reduction in Mortality and Morbidity], CORONA [Controlled Rosuvastatin Multinational Trial in Heart Failure], and MAGGIC [Meta-Analysis Global Group in Chronic Heart Failure]). Median contrast volume was 109 mL. Both contrast media caused similarly small but statistically significant changes in most hemodynamic variables. There were 39 adverse events (26.0%). Adverse event rates increased using the composite metric of baseline PCWP and change in CI (Pcontrast correlated with the poorest prognosis. Adding both baseline PCWP and change in CI to the 5 risk models universally improved their predictive value (P≤0.02). In heart failure patients, the administration of contrast causes small but significant changes in hemodynamics. Calculating baseline PCWP with change in CI after contrast predicts adverse events and increases the predictive value of existing models. Patients with elevated baseline PCWP and

  8. Secondhand tobacco smoke exposure and heart rate variability and inflammation among non-smoking construction workers: a repeated measures study.

    Science.gov (United States)

    Zhang, Jinming; Fang, Shona C; Mittleman, Murray A; Christiani, David C; Cavallari, Jennifer M

    2013-10-02

    Although it has been well recognized that exposure to secondhand tobacco smoke (SHS) is associated with cardiovascular mortality, the mechanisms and time course by which SHS exposure may lead to cardiovascular effects are still being explored. Non-smoking workers were recruited from a local union and monitored inside a union hall while exposed to SHS over approximately 6 hours. Participants were fitted with a continuous electrocardiographic monitor upon enrollment which was removed at the end of a 24-hr monitoring period. A repeated measures study design was used where resting ECGs and blood samples were taken from individuals before SHS exposure (baseline), immediately following SHS exposure (post) and the morning following SHS exposure (next-morning).Inflammatory markers, including high sensitivity C-reactive protein (CRP) and white blood cell count (WBC) were analyzed. Heart rate variability (HRV) was analyzed from the ECG recordings in time (SDNN, rMSSD) and frequency (LF, HF) domain parameters over 5-minute periods. SHS exposure was quantified using a personal fine particulate matter (PM2.5) monitor.Linear mixed effects regression models were used to examine within-person changes in inflammatory and HRV parameters across the 3 time periods. Exposure-response relationships with PM2.5 were examined using mixed effects models. All models were adjusted for age, BMI and circadian variation. A total of 32 male non-smokers were monitored between June 2010 and June 2012. The mean PM2.5 from SHS exposure was 132 μg/m3. Immediately following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with declines in HRV (7.8% [standard error (SE) =3%] SDNN, 8.0% (SE = 3.9%) rMSSD, 17.2% (SE = 6.3%) LF, 29.0% (SE = 10.1%) HF) and increases in WBC count 0.42 (SE = 0.14) k/μl. Eighteen hours following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with 24.2% higher CRP levels. Our study suggest that short-term SHS exposure is associated

  9. The TDAQ Baseline Architecture

    CERN Multimedia

    Wickens, F J

    The Trigger-DAQ community is currently busy preparing material for the DAQ, HLT and DCS TDR. Over the last few weeks a very important step has been a series of meetings to complete agreement on the baseline architecture. An overview of the architecture indicating some of the main parameters is shown in figure 1. As reported at the ATLAS Plenary during the February ATLAS week, the main area where the baseline had not yet been agreed was around the Read-Out System (ROS) and details in the DataFlow. The agreed architecture has: Read-Out Links (ROLs) from the RODs using S-Link; Read-Out Buffers (ROB) sited near the RODs, mounted in a chassis - today assumed to be a PC, using PCI bus at least for configuration, control and monitoring. The baseline assumes data aggregation, in the ROB and/or at the output (which could either be over a bus or in the network). Optimization of the data aggregation will be made in the coming months, but the current model has each ROB card receiving input from 4 ROLs, and 3 such c...

  10. Effects of baseline conditions on the simulated hydrologic response to projected climate change

    Science.gov (United States)

    Koczot, Kathryn M.; Markstrom, Steven L.; Hay, Lauren E.

    2011-01-01

    Changes in temperature and precipitation projected from five general circulation models, using one late-twentieth-century and three twenty-first-century emission scenarios, were downscaled to three different baseline conditions. Baseline conditions are periods of measured temperature and precipitation data selected to represent twentieth-century climate. The hydrologic effects of the climate projections are evaluated using the Precipitation-Runoff Modeling System (PRMS), which is a watershed hydrology simulation model. The Almanor Catchment in the North Fork of the Feather River basin, California, is used as a case study. Differences and similarities between PRMS simulations of hydrologic components (i.e., snowpack formation and melt, evapotranspiration, and streamflow) are examined, and results indicate that the selection of a specific time period used for baseline conditions has a substantial effect on some, but not all, hydrologic variables. This effect seems to be amplified in hydrologic variables, which accumulate over time, such as soil-moisture content. Results also indicate that uncertainty related to the selection of baseline conditions should be evaluated using a range of different baseline conditions. This is particularly important for studies in basins with highly variable climate, such as the Almanor Catchment.

  11. Infrared thermometry and the crop water stress index. I. History, theory, and baselines

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Development of portable infrared thermometers and the definition of the Crop Water Stress Index (CWSI) have led to widespread interest in infrared thermometry to monitor water stress and schedule irrigations. But the CWSI concept is still new and poorly understood by many. The purpose of this paper is to review the definition of CWSI, and the determination and interpretation of the non-water-stressed baselines used to compute CWSI. The non-water-stressed baseline equation normalizes the canopy minus air temperature differential for variations in vapor pressure deficit. Non-water-stressed baselines can be determined empirically from measurements of canopy and air temperatures and vapor pressure deficit, made diurnally on a single day, or at a single time of day over many days, on well-watered plants. The value of the maximum canopy minus air temperature differential under maximum water stress should also be determined empirically. Causes for CWSI values falling outside of the defined 0 to 10 unit range are reviewed. Non-water-stressed baselines may shift with plant growth stage. Effective use of CWSI is dependent on understanding the definition of CWSI, and the proper determination and use of non-water-stressed baselines. (author)

  12. Safe and sensible preprocessing and baseline correction of pupil-size data

    NARCIS (Netherlands)

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a

  13. Safe and sensible preprocessing and baseline correction of pupil-size data

    NARCIS (Netherlands)

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    2018-01-01

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, that is, analyzing changes in pupil size relative to a

  14. simple sequence repeats (EST-SSR)

    African Journals Online (AJOL)

    Yomi

    2012-01-19

    Jan 19, 2012 ... 212 primer pairs selected, based on repeat patterns of n≥8 for di-, tri-, tetra- and penta-nucleotide repeat ... Cluster analysis revealed a high genetic similarity among the sugarcane (Saccharum spp.) breeding lines which could reduce the genetic gain in ..... The multiple allele characteristic of SSR com-.

  15. Nifty Nines and Repeating Decimals

    Science.gov (United States)

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  16. Repeated Prescribed Burning in Aspen

    Science.gov (United States)

    Donald A. Perala

    1974-01-01

    Infrequent burning weather, low flammability of the aspen-hardwood association, and prolific sprouting and seeding of shrubs and hardwoods made repeated dormant season burning a poor tool to convert good site aspen to conifers. Repeat fall burns for wildlife habitat maintenance is workable if species composition changes are not important.

  17. THE US LONG BASELINE NEUTRINO EXPERIMENT STUDY.

    Energy Technology Data Exchange (ETDEWEB)

    BISHAI,M.

    2007-08-06

    The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory (BNL)and Fermi National Accelerator Laboratory (FNAL) to investigate the potential for future U.S. based long baseline neutrino oscillation experiments using MW class conventional neutrino beams that can be produced at FNAL. The experimental baselines are based on two possible detector locations: (1) off-axis to the existing FNAL NuMI beamline at baselines of 700 to 810 km and (2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from FNAL aimed at a massive detector with a baseline of > 1000km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2{sup o}.

  18. The importance of position and path repeatability on force at the knee during six-DOF joint motion.

    Science.gov (United States)

    Darcy, Shon P; Gil, Jorge E; Woo, Savio L-Y; Debski, Richard E

    2009-06-01

    Mechanical devices, such as robotic manipulators have been designed to measure joint and ligament function because of their ability to position a diarthrodial joint in six degrees-of-freedom with fidelity. However, the precision and performance of these testing devices vary. Therefore, the objective of this study was to determine the effect of systematic errors in position and path repeatability of two high-payload robotic manipulators (Manipulators 1 and 2) on the resultant forces at the knee. Using a porcine knee, the position and path repeatability of these manipulators were determined during passive flexion-extension with a coordinate measuring machine. The position repeatability of Manipulator 1 was 0.3 mm in position and 0.2 degrees in orientation while Manipulator 2 had a better position repeatability of 0.1 mm in position and 0.1 degrees in orientation throughout the range of positions examined. The corresponding variability in the resultant force at the knee for these assigned positions was 32+/-33 N for Manipulator 1 and 4+/-1 N for Manipulator 2. Furthermore, the repeatability of the trajectory of each manipulator while moving between assigned positions (path repeatability) was 0.8 mm for Manipulator 1 while the path repeatability for Manipulator 2 was improved (0.1 mm). These path discrepancies produced variability in the resultant force at the knee of 44+/-24 and 21+/-8 N, respectively, for Manipulators 1 and 2 primarily due to contact between the articular surfaces of the tibia and femur. Therefore, improved position and path repeatability yields lower variability in the resultant forces at the knee. Although position repeatability has been the most common criteria for evaluating biomechanical testing devices, the current study has clearly demonstrated that path repeatability can have an even larger effect on the variability in resultant force at the knee. Consequently, the repeatability of the path followed by the joint throughout its prescribed

  19. What Can We Learn From Point-of-Care Blood Glucose Values Deleted and Repeated by Nurses?

    Science.gov (United States)

    Corl, Dawn; Yin, Tom; Ulibarri, May; Lien, Heather; Tylee, Tracy; Chao, Jing; Wisse, Brent E

    2018-03-01

    Hospitals rely on point-of-care (POC) blood glucose (BG) values to guide important decisions related to insulin administration and glycemic control. Evaluation of POC BG in hospitalized patients is associated with measurement and operator errors. Based on a previous quality improvement (QI) project we introduced an option for operators to delete and repeat POC BG values suspected as erroneous. The current project evaluated our experience with deleted POC BG values over a 2-year period. A retrospective QI project included all patients hospitalized at two regional academic medical centers in the Pacific Northwest during 2014 and 2015. Laboratory Medicine POC BG data were reviewed to evaluate all inpatient episodes of deleted and repeated POC BG. Inpatient operators choose to delete and repeat only 0.8% of all POC BG tests. Hypoglycemic and extreme hyperglycemic BG values are more likely to be deleted and repeated. Of initial values values (18% of all values) are errors. Of values >400 mg/dL, 40% of deleted values (5% of all values) are errors. Not all repeated POC BG values are first deleted. Optimal use of the option to delete and repeat POC BG values values that are measurement/operator errors. Eliminating these errors significantly reduces documented rates of severe hypoglycemia and hyperglycemia, and has the potential to improve patient safety.

  20. The effects of repeated low-level blast exposure on hearing in marines

    Directory of Open Access Journals (Sweden)

    Lina R Kubli

    2017-01-01

    Full Text Available Background: The study evaluates a group of Military Service Members specialized in blast explosive training called “Breachers” who are routinely exposed to multiple low-level blasts while teaching breaching at the U.S. Marine Corps in Quantico Virginia. The objective of this study was to determine if there are any acute or long-term auditory changes due to repeated low-level blast exposures used in training. The performance of the instructor group “Breachers” was compared to a control group, “Engineers”. Methods: A total of 11 Breachers and four engineers were evaluated in the study. The participants received comprehensive auditory tests, including pure-tone testing, speech-in-noise (SIN measures, and central auditory behavioral and objective tests using early and late (P300 auditory evoked potentials over a period of 17 months. They also received shorter assessments immediately following the blast-exposure onsite at Quantico. Results: No acute or longitudinal effects were identified. However, there were some interesting baseline effects found in both groups. Contrary to the expected, the onsite hearing thresholds and distortion product otoacoustic emissions were slightly better at a few frequencies immediately after blast-exposure than measurements obtained with the same equipment weeks to months after each blast-exposure. Conclusions: To date, the current study is the most comprehensive study that evaluates the long-term effects of blast-exposure on hearing. Despite extensive testing to assess changes, the findings of this study suggest that the levels of current exposures used in this military training environment do not seem to have an obvious deleterious effect on hearing.

  1. Visual attention to repeated print advertising : A test of scanpath theory

    NARCIS (Netherlands)

    Pieters, F.G.M.; Rosbergen, E.; Wedel, M.

    1999-01-01

    The authors examine consumers' visual attention during repeated exposures to print advertisements using eye-tracking methodology. The authors propose a statistical model comprising submodels for two key measures of visual attention to elements of the advertisement: attention duration and inter- and

  2. Visual attention to repeated print advertising : A test of scanpath theory

    NARCIS (Netherlands)

    Pieters, F.G.M.; Rosbergen, E.; Wedel, M.

    The authors examine consumers' visual attention during repeated exposures to print advertisements using eye-tracking methodology. The authors propose a statistical model comprising submodels for two key measures of visual attention to elements of the advertisement: attention duration and inter- and

  3. Pipeline integrity: ILI baseline data for QRA

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Todd R. [Tuboscope Pipeline Services, Houston, TX (United States)]. E-mail: tporter@varco.com; Silva, Jose Augusto Pereira da [Pipeway Engenharia, Rio de Janeiro, RJ (Brazil)]. E-mail: guto@pipeway.com; Marr, James [MARR and Associates, Calgary, AB (Canada)]. E-mail: jmarr@marr-associates.com

    2003-07-01

    The initial phase of a pipeline integrity management program (IMP) is conducting a baseline assessment of the pipeline system and segments as part of Quantitative Risk Assessment (QRA). This gives the operator's integrity team the opportunity to identify critical areas and deficiencies in the protection, maintenance, and mitigation strategies. As a part of data gathering and integration of a wide variety of sources, in-line inspection (ILI) data is a key element. In order to move forward in the integrity program development and execution, the baseline geometry of the pipeline must be determined with accuracy and confidence. From this, all subsequent analysis and conclusions will be derived. Tuboscope Pipeline Services (TPS), in conjunction with Pipeway Engenharia of Brazil, operate ILI inertial navigation system (INS) and Caliper geometry tools, to address this integrity requirement. This INS and Caliper ILI tool data provides pipeline trajectory at centimeter level resolution and sub-metre 3D position accuracy along with internal geometry - ovality, dents, misalignment, and wrinkle/buckle characterization. Global strain can be derived from precise INS curvature measurements and departure from the initial pipeline state. Accurate pipeline elevation profile data is essential in the identification of sag/over bend sections for fluid dynamic and hydrostatic calculations. This data, along with pipeline construction, operations, direct assessment and maintenance data is integrated in LinaViewPRO{sup TM}, a pipeline data management system for decision support functions, and subsequent QRA operations. This technology provides the baseline for an informed, accurate and confident integrity management program. This paper/presentation will detail these aspects of an effective IMP, and experience will be presented, showing the benefits for liquid and gas pipeline systems. (author)

  4. Satellite-Surface Perspectives of Air Quality and Aerosol-Cloud Effects on the Environment: An Overview of 7-SEAS BASELInE

    Science.gov (United States)

    Tsay, Si-Chee; Maring, Hal B.; Lin, Neng-Huei; Buntoung, Sumaman; Chantara, Somporn; Chuang, Hsiao-Chi; Gabriel, Philip M.; Goodloe, Colby S.; Holben, Brent N.; Hsiao, Ta-Chih; hide

    2016-01-01

    The objectives of 7-SEASBASELInE (Seven SouthEast Asian Studies Biomass-burning Aerosols and Stratocumulus Environment: Lifecycles and Interactions Experiment) campaigns in spring 2013-2015 were to synergize measurements from uniquely distributed ground-based networks (e.g., AERONET (AErosol RObotic NETwork)), MPLNET ( NASA Micro-Pulse Lidar Network)) and sophisticated platforms (e.g.,SMARTLabs (Surface-based Mobile Atmospheric Research and Testbed Laboratories), regional contributing instruments), along with satellite observations retrievals and regional atmospheric transport chemical models to establish a critically needed database, and to advance our understanding of biomass-burning aerosols and trace gases in Southeast Asia (SEA). We present a satellite-surface perspective of 7-SEASBASELInE and highlight scientific findings concerning: (1) regional meteorology of moisture fields conducive to the production and maintenance of low-level stratiform clouds over land; (2) atmospheric composition in a biomass-burning environment, particularly tracers-markers to serve as important indicators for assessing the state and evolution of atmospheric constituents; (3) applications of remote sensing to air quality and impact on radiative energetics, examining the effect of diurnal variability of boundary-layer height on aerosol loading; (4) aerosol hygroscopicity and ground-based cloud radar measurements in aerosol-cloud processes by advanced cloud ensemble models; and (5) implications of air quality, in terms of toxicity of nanoparticles and trace gases, to human health. This volume is the third 7-SEAS special issue (after Atmospheric Research, vol. 122, 2013; and Atmospheric Environment, vol. 78, 2013) and includes 27 papers published, with emphasis on air quality and aerosol-cloud effects on the environment. BASELInE observations of stratiform clouds over SEA are unique, such clouds are embedded in a heavy aerosol-laden environment and feature characteristically greater

  5. Thermal stability of chicken brain {alpha}-spectrin repeat 17: a spectroscopic study

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, Annette K. [University of Bergen, Department of Chemistry (Norway); Kieffer, Bruno [Ecole Superieure de Biotechnologie de Strasbourg, IGBMC Biomolecular NMR Group, CNRS UMR 7104 (France); Trave, Gilles [Ecole Superieure de Biotechnologie de Strasbourg, Equipe Oncoproteines, IREBS, UMR 7242 (France); Froystein, Nils Age [University of Bergen, Department of Chemistry (Norway); Raae, Arnt J., E-mail: arnt.raae@mbi.uib.no [University of Bergen, Department of Molecular Biology (Norway)

    2012-06-15

    Spectrin is a rod-like multi-modular protein that is mainly composed of triple-helical repeats. These repeats show very similar 3D-structures but variable conformational and thermodynamical stabilities, which may be of great importance for the flexibility and dynamic behaviour of spectrin in the cell. For instance, repeat 17 (R17) of the chicken brain spectrin {alpha}-chain is four times less stable than neighbouring repeat 16 (R16) in terms of Increment G. The structure of spectrin repeats has mainly been investigated by X-ray crystallography, but the structures of a few repeats, e.g. R16, have also been determined by NMR spectroscopy. Here, we undertook a detailed characterization of the neighbouring R17 by NMR spectroscopy. We assigned most backbone resonances and observed NOE restraints, relaxation values and coupling constants that all indicated that the fold of R17 is highly similar to that of R16, in agreement with previous X-ray analysis of a tandem repeat of the two domains. However, {sup 15}N heteronuclear NMR spectra measured at different temperatures revealed particular features of the R17 domain that might contribute to its lower stability. Conformational exchange appeared to alter the linker connecting R17 to R16 as well as the BC-loop in close proximity. In addition, heat-induced splitting was observed for backbone resonances of a few spatially related residues including V99 of helix C, which in R16 is replaced by the larger hydrophobic tryptophan residue that is relatively conserved among other spectrin repeats. These data support the view that the substitution of tryptophan by valine at this position may contribute to the lower stability of R17.

  6. A novel approach for baseline correction in 1H-MRS signals based on ensemble empirical mode decomposition.

    Science.gov (United States)

    Parto Dezfouli, Mohammad Ali; Dezfouli, Mohsen Parto; Rad, Hamidreza Saligheh

    2014-01-01

    Proton magnetic resonance spectroscopy ((1)H-MRS) is a non-invasive diagnostic tool for measuring biochemical changes in the human body. Acquired (1)H-MRS signals may be corrupted due to a wideband baseline signal generated by macromolecules. Recently, several methods have been developed for the correction of such baseline signals, however most of them are not able to estimate baseline in complex overlapped signal. In this study, a novel automatic baseline correction method is proposed for (1)H-MRS spectra based on ensemble empirical mode decomposition (EEMD). This investigation was applied on both the simulated data and the in-vivo (1)H-MRS of human brain signals. Results justify the efficiency of the proposed method to remove the baseline from (1)H-MRS signals.

  7. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Science.gov (United States)

    Reed, Katharine; Wood, Carly; Barton, Jo; Pretty, Jules N; Cohen, Daniel; Sandercock, Gavin R H

    2013-01-01

    Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run) and self-reported physical activity (PAQ-A) in 11 and 12 year olds (n = 75). Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE) and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74), = 12.2, pself-esteem following exercise but there was no condition by exercise interaction (F (1,74), = 0.13, p = 0.72). There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04) between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55). Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  8. Quantification of in vivo 1H magnetic resonance spectroscopy signals with baseline and lineshape estimation

    International Nuclear Information System (INIS)

    Osorio-Garcia, M I; Sima, D M; Van Huffel, S; Nielsen, F U; Dresselaers, T; Himmelreich, U; Van Leuven, F

    2011-01-01

    The in vivo quantification of magnetic resonance spectroscopy (MRS) signals is a method to estimate metabolite concentrations of living tissue. Obtaining reliable concentrations is still a challenge due to the experimental conditions affecting spectral quality. Additionally, lipids and macromolecules overlap with the metabolites of interest, affecting their reliable estimation. In this study, we propose to combine the self-deconvolution lineshape estimation method, which accounts for spectral shape distortions, with two different approaches for taking into account the macromolecular baseline contribution: (a) based on macromolecules and lipids measured in vivo using an inversion recovery technique, and (b) based on the simulation of macromolecular resonances using prior knowledge from a database of inversion recovery signals. The ultimate goal is to measure macromolecular and lipid data only once as described in (a) to create macromolecular and lipid profiles. These profiles then can be used as described in (b) for data measured under the same conditions. The method is evaluated on in vivo 1 H MRS signals at 9.4 T from mouse hippocampus. Results show that better metabolite fits are obtained when lineshape and baseline estimations are simultaneously performed and that baseline estimation based on prior knowledge from macromolecular measured signals can be reliably used to replace time-consuming individual macromolecular and lipid acquisitions

  9. Polymorphic repeat in AIB1 does not alter breast cancer risk

    International Nuclear Information System (INIS)

    Haiman, Christopher A; Hankinson, Susan E; Spiegelman, Donna; Colditz, Graham A; Willett, Walter C; Speizer, Frank E; Brown, Myles; Hunter, David J

    2000-01-01

    initial questionnaire reporting medical histories and baseline health-related exposures. Between 1989 and 1990 blood samples were collected from 32 826 women. Eligible cases in this study consisted of women with pathologically confirmed incident breast cancer from the subcohort who gave a blood specimen. Cases with a diagnosis anytime after blood collection up to June 1, 1994, with no previously diagnosed cancer except for nonmelanoma skin cancer were included. Controls were randomly selected participants who gave a blood sample and were free of diagnosed cancer (except nonmelanoma skin cancer) up to and including the interval in which the cases were diagnosed, and were matched to cases on year of birth, menopausal status, postmenopausal hormone use, and time of day, month and fasting status at blood sampling. The nested case-control study consisted of 464 incident breast cancer cases and 624 matched controls. The protocol was approved by the Committee on Human Subjects, Brigham and Womens' Hospital, Boston, Massachusetts USA. Information regarding breast cancer risk factors was obtained from the 1976 baseline questionnaire, subsequent biennial questionnaires, and a questionnaire that was completed at the time of blood sampling. Histopathologic characteristics, such as stage, tumor size and ER and progesterone receptor (PR) status, were ascertained from medical records when available and used in case subgroup analyses. AIB1 repeat alleles were determined by automated fluorescence-based fragment detection from polymerase chain reaction (PCR)-amplified DNA extracted from peripheral blood lymphocytes. Fluorescent 5' -labeled primers were utilized for PCR amplification, and glutamine repeat number discrimination was performed using the ABI Prism 377 DNA Sequencer (Perkin-Elmer, Foster City, CA, USA). Genotyping was performed by laboratory personnel who were blinded to case-control status, and blinded quality control samples were inserted to validate genotyping

  10. An Improved Rank Correlation Effect Size Statistic for Single-Case Designs: Baseline Corrected Tau.

    Science.gov (United States)

    Tarlow, Kevin R

    2017-07-01

    Measuring treatment effects when an individual's pretreatment performance is improving poses a challenge for single-case experimental designs. It may be difficult to determine whether improvement is due to the treatment or due to the preexisting baseline trend. Tau- U is a popular single-case effect size statistic that purports to control for baseline trend. However, despite its strengths, Tau- U has substantial limitations: Its values are inflated and not bound between -1 and +1, it cannot be visually graphed, and its relatively weak method of trend control leads to unacceptable levels of Type I error wherein ineffective treatments appear effective. An improved effect size statistic based on rank correlation and robust regression, Baseline Corrected Tau, is proposed and field-tested with both published and simulated single-case time series. A web-based calculator for Baseline Corrected Tau is also introduced for use by single-case investigators.

  11. Robust extraction of baseline signal of atmospheric trace species using local regression

    Directory of Open Access Journals (Sweden)

    A. F. Ruckstuhl

    2012-11-01

    Full Text Available The identification of atmospheric trace species measurements that are representative of well-mixed background air masses is required for monitoring atmospheric composition change at background sites. We present a statistical method based on robust local regression that is well suited for the selection of background measurements and the estimation of associated baseline curves. The bootstrap technique is applied to calculate the uncertainty in the resulting baseline curve. The non-parametric nature of the proposed approach makes it a very flexible data filtering method. Application to carbon monoxide (CO measured from 1996 to 2009 at the high-alpine site Jungfraujoch (Switzerland, 3580 m a.s.l., and to measurements of 1,1-difluoroethane (HFC-152a from Jungfraujoch (2000 to 2009 and Mace Head (Ireland, 1995 to 2009 demonstrates the feasibility and usefulness of the proposed approach.

    The determined average annual change of CO at Jungfraujoch for the 1996 to 2009 period as estimated from filtered annual mean CO concentrations is −2.2 ± 1.1 ppb yr−1. For comparison, the linear trend of unfiltered CO measurements at Jungfraujoch for this time period is −2.9 ± 1.3 ppb yr−1.

  12. The Pentapeptide Repeat Proteins

    OpenAIRE

    Vetting, Matthew W.; Hegde, Subray S.; Fajardo, J. Eduardo; Fiser, Andras; Roderick, Steven L.; Takiff, Howard E.; Blanchard, John S.

    2006-01-01

    The Pentapeptide Repeat Protein (PRP) family has over 500 members in the prokaryotic and eukaryotic kingdoms. These proteins are composed of, or contain domains composed of, tandemly repeated amino acid sequences with a consensus sequence of [S,T,A,V][D,N][L,F]-[S,T,R][G]. The biochemical function of the vast majority of PRP family members is unknown. The three-dimensional structure of the first member of the PRP family was determined for the fluoroquinolone resistance protein (MfpA) from Myc...

  13. Baseline simple and complex reaction times in female compared to male boxers.

    Science.gov (United States)

    Bianco, M; Ferri, M; Fabiano, C; Giorgiano, F; Tavella, S; Manili, U; Faina, M; Palmieri, V; Zeppilli, P

    2011-06-01

    The aim of the study was to compare baseline cognitive performance of female in respect to male amateur boxers. Study population included 28 female amateur boxers. Fifty-six male boxers, matched for age, employment and competitive level to female athletes, formed the control group. All boxers had no history of head concussions (except boxing). Each boxer was requested to: 1) fulfill a questionnaire collecting demographic data, level of education, occupational status, boxing record and number of head concussions during boxing; 2) undergo a baseline computerized neuropsychological (NP) test (CogSport) measuring simple and complex reaction times (RT). Female were lighter than male boxers (56±7 vs. 73.1±9.8 kg, Pknock-outs, etc.) correlated with NP scores. Female and male Olympic-style boxers have no (or minimal) differences in baseline cognitive performance. Further research with larger series of female boxers is required to confirm these findings.

  14. DGEMP-OE (2008) Energy Baseline Scenario. Synthesis report

    International Nuclear Information System (INIS)

    2008-01-01

    A 'Business as usual' or 'Baseline' scenario of energy trends to 2020-2030 is produced by France every four years, as requested by the International Energy Agency in order to update the global scenarios published in its World Energy Outlook. Since the most recent scenario of this type was drawn up in 2003-2004, the time has come to renew the effort for the IEA's next in-depth review of French energy policy. Specifically, the DGEMP seeks to predict the future of France's energy situation assuming that no policies or new measures are taken affecting (i.e. improving or deteriorating) the situation other than those already in place or adopted as of 1 January 2008 (in other words, before measures such as those stemming from the Grenelle Environment Forum). On the other hand, it is assumed that change in the energy system is guided by 'conventional wisdom' according to which political options and behaviours by economic units are expected to be 'reasonable'. As a result, even should its projections prove inappropriate, this cannot be considered a 'worst-case' scenario. Indeed, beyond the IEA, this scenario can be used to establish an MEA (Multilateral Environment Agreement) scenario (based on existing measures) for national communications submitted under the U.N. Climate Convention. The scenarios by the 'Energy' Commission, part of the Centre d'Analyse Strategique (CAS), could have been used, particularly since the consultant who worked with the CAS to develop its scenarios was also commissioned by the DGEMP. However, several considerations argued in favour of proceeding separately: - The CAS scenarios drew on the DGEMP's 2004 baseline scenario, even though certain parameters were updated (in particular energy prices). - Moreover, the concept underpinning the DGEMP baseline scenario is that it should to every extent possible remain constant over time to secure continued consensus on this 'reference' at national level. - Finally, the MEDEE energy demand model applied in

  15. Muscle Damage and Metabolic Responses to Repeated-Sprint Running With and Without Deceleration.

    Science.gov (United States)

    Minahan, Clare L; Poke, Daniel P; Morrison, Jaime; Bellinger, Phillip M

    2018-04-04

    Minahan, CL, Poke, DP, Morrison, J, and Bellinger, PM. Muscle damage and metabolic responses to repeated-sprint running with and without deceleration. J Strength Cond Res XX(X): 000-000, 2017-This study aimed to determine whether repeated-sprint running with deceleration aggravates markers of muscle damage or delays the recovery of performance compared with repeated-sprint running without deceleration. Fourteen male team-sport athletes performed 2 randomly ordered testing sessions on a nonmotorized treadmill with one session requiring participants to decelerate (TMd) within 4 seconds before stopping or immediately step to the side of the treadmill belt at the completion of each sprint (TMa). Peak and mean velocities, speed decrement, blood lactate concentrations, and oxygen uptake were monitored during the repeated-sprint running protocols. Countermovement vertical jump (CMJ) performance, perceived muscle soreness, sit-and-reach flexibility, plasma creatine kinase (CK), lactate dehydrogenase (LDH), and myoglobin (Mb) concentrations were quantified immediately before and after and 45 minutes, 24 and 48 hours after repeated-sprint running protocols. Although muscle damage was indicated by increases in CK, LDH, and Mb (p ≤ 0.05) in both groups, there was no significant effect of condition (TMa vs. TMd) on any of the measured performance or physiological variables (p > 0.05). The present study indicated that the removal of deceleration from repeated-sprint running on a nonmotorized treadmill has no effect on metabolism or performance during or after repeated-sprint running or markers of muscle damage.

  16. Magnetic Repeat Station Network on the Baltic Sea — Why So Needed?

    Directory of Open Access Journals (Sweden)

    Welker Elżbieta

    2017-12-01

    Full Text Available The development of navigation systems requires more and more accurate base data. Currently, attention is paid to utilization of geophysical fields — gravitational and magnetic ones — for navigation purposes. The Earth’s magnetic field distribution — both onshore and offshore — is complicated and variable in time. Hence, it is essential to precisely know the secular variations in the area of interest. In the case of Baltic Sea, this involves establishing (re-establishing of a marine network of secular points (repeat stations and regular magnetic measurements of the three independent components of the Earth’s magnetic field. Such measurements require equipment that ensures not only high stability, but also information about sensors’ orientation in relation to geographic north and to the level. This article presents a new project of the Baltic network of repeat stations and gives a solution for the instruments usable for quasi-absolute magnetic measurements.

  17. Baseline metal concentrations in Paramoera walkeri from East Antarctica

    International Nuclear Information System (INIS)

    Palmer, Anne S. . E-mail Anne.Palmer@utas.edu.au; Snape, Ian; Stark, Jonathan S.; Johnstone, Glenn J.; Townsend, Ashley T.

    2006-01-01

    Remediation of the Thala Valley waste disposal site near Casey Station, East Antarctica was conducted in the austral summer of 2003/2004. Biomonitoring of the adjacent marine environment was undertaken using the gammaridean amphipod Paramoera walkeri as a sentinel species [Stark, J.S., Johnstone, G.J., Palmer, A.S., Snape, I., Larner, B.L., Riddle, M.J., in press, doi:10.1016/j.marpolbul.2006.05.020. Monitoring the remediation of a near shore waste disposal site in Antarctica using the amphipod Paramoera walkeri and diffusive gradients in thin films (DGTs). Marine Pollution Bulletin and references therein]. Determination of uptake of metals and hypothesis testing for differences that could be attributed to contamination required the establishment of baseline metal concentrations in P. walkeri. Baseline metal concentrations from two reference locations in the Windmill Islands are presented here. P. walkeri was a found to be a sensitive bioaccumulating organism that recorded spatial and temporal variability at the reference sites. Measurement of metals in P. walkeri required the development of a simple digestion procedure that used concentrated nitric acid. For the first time, rare earth metals were determined with additional clean procedures required to measure ultra low concentrations using magnetic sector ICP-MS. Certified and in-house reference materials were employed to ensure method reliability

  18. Repeatability of a 3D multi-segment foot model protocol in presence of foot deformities.

    Science.gov (United States)

    Deschamps, Kevin; Staes, Filip; Bruyninckx, Herman; Busschots, Ellen; Matricali, Giovanni A; Spaepen, Pieter; Meyer, Christophe; Desloovere, Kaat

    2012-07-01

    Repeatability studies on 3D multi-segment foot models (3DMFMs) have mainly considered healthy participants which contrasts with the widespread application of these models to evaluate foot pathologies. The current study aimed at establishing the repeatability of the 3DMFM described by Leardini et al. in presence of foot deformities. Foot kinematics of eight adult participants were analyzed using a repeated-measures design including two therapists with different levels of experience. The inter-trial variability was higher compared to the kinematics of healthy subjects. Consideration of relative angles resulted in the lowest inter-session variability. The absolute 3D rotations between the Sha-Cal and Cal-Met seem to have the lowest variability in both therapists. A general trend towards higher σ(sess)/σ(trial) ratios was observed when the midfoot was involved. The current study indicates that not only relative 3D rotations and planar angles can be measured consistently in patients, also a number of absolute parameters can be consistently measured serving as basis for the decision making process. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Skin conductance at baseline and postheel lance reflects sympathetic activation in neonatal opiate withdrawal.

    Science.gov (United States)

    Oji-Mmuo, Christiana N; Michael, Eric J; McLatchy, Jacqueline; Lewis, Mary M; Becker, Julie E; Doheny, Kim Kopenhaver

    2016-03-01

    Skin conductance (SC) provides an objective measure of autonomic system regulation through sympathetic-mediated filling of sweat glands. This study aimed to test the utility of SC to detect sympathetic activation in neonatal abstinence syndrome (NAS). Fourteen term (mean, SE: 38.8 ± 0.35 weeks gestational age) neonates with chronic prenatal opiate exposure were enrolled. SC (peaks/seconds and mean of peaks) was measured at baseline, during heel lance/squeeze (HLS) and recovery from HLS at 24-48 (mean 38) hours of life prior to treatment for NAS. Blinded coders with established reliability assessed neonates using the Modified Finnegan Neonatal Scoring System (MFNSS). Nonparametric tests were used to determine group differences, phase differences from baseline to HLS and HLS to recovery, and associations between MFNSS and SC measures. Neonates that would later require morphine treatment for NAS (n = 6) had higher baseline SC mean of peaks than those that did not require treatment (n = 8) (p < 0.05). Moreover, there were unique phase differences between groups and SC positively correlated with MFNSS (p < 0.05). SC provides early identification of NAS severity. However, a larger sample is needed to determine sensitivity and specificity of SC for early identification of NAS and treatment effectiveness. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  20. Long Baseline Observatory (LBO)

    Data.gov (United States)

    Federal Laboratory Consortium — The Long Baseline Observatory (LBO) comprises ten radio telescopes spanning 5,351 miles. It's the world's largest, sharpest, dedicated telescope array. With an eye...

  1. SeqEntropy: genome-wide assessment of repeats for short read sequencing.

    Directory of Open Access Journals (Sweden)

    Hsueh-Ting Chu

    Full Text Available BACKGROUND: Recent studies on genome assembly from short-read sequencing data reported the limitation of this technology to reconstruct the entire genome even at very high depth coverage. We investigated the limitation from the perspective of information theory to evaluate the effect of repeats on short-read genome assembly using idealized (error-free reads at different lengths. METHODOLOGY/PRINCIPAL FINDINGS: We define a metric H(k to be the entropy of sequencing reads at a read length k and use the relative loss of entropy ΔH(k to measure the impact of repeats for the reconstruction of whole-genome from sequences of length k. In our experiments, we found that entropy loss correlates well with de-novo assembly coverage of a genome, and a score of ΔH(k>1% indicates a severe loss in genome reconstruction fidelity. The minimal read lengths to achieve ΔH(k<1% are different for various organisms and are independent of the genome size. For example, in order to meet the threshold of ΔH(k<1%, a read length of 60 bp is needed for the sequencing of human genome (3.2 10(9 bp and 320 bp for the sequencing of fruit fly (1.8×10(8 bp. We also calculated the ΔH(k scores for 2725 prokaryotic chromosomes and plasmids at several read lengths. Our results indicate that the levels of repeats in different genomes are diverse and the entropy of sequencing reads provides a measurement for the repeat structures. CONCLUSIONS/SIGNIFICANCE: The proposed entropy-based measurement, which can be calculated in seconds to minutes in most cases, provides a rapid quantitative evaluation on the limitation of idealized short-read genome sequencing. Moreover, the calculation can be parallelized to scale up to large euakryotic genomes. This approach may be useful to tune the sequencing parameters to achieve better genome assemblies when a closely related genome is already available.

  2. Diffusion-weighted (DW) MRI in lung cancers. ADC test-retest repeatability

    Energy Technology Data Exchange (ETDEWEB)

    Weller, Alex; Papoutsaki, Marianthi Vasiliki; Blackledge, Matthew; DeSouza, Nandita M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK Cancer Imaging Centre, Surrey (United Kingdom); Waterton, John C. [University of Manchester, Manchester (United Kingdom); Chiti, Arturo [Humanitas University, Milan (Italy); Stroobants, Sigrid [Universiteit Antwerpen, Antwerpen (Belgium); Kuijer, Joost [Vrije Universiteit Medisch Centrum, Amsterdam (Netherlands); Morgan, Veronica [Royal Marsden NHS Foundation Trust, Department of Medicine, London (United Kingdom)

    2017-11-15

    To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800 s/mm{sup -2}). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. Whole-tumour ADC values ranged from 0.66-1.94x10{sup -3} mm{sup 2}s{sup -1} (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R{sup 2} = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. (orig.)

  3. Advanced fiber information systems seed coat neps baseline response from diverse mediums

    Science.gov (United States)

    An extensive literature search has revealed that no papers have been published regarding selectivity calculation of the AFIS seed coat neps (SCN) determination over interfering material in cotton. A prerequisite to selectivity measurements is to identify suitable fiber medium(s) that give baseline ...

  4. PROPOSAL OF A TABLE TO CLASSIFY THE RELIABILITY OF BASELINES OBTAINED BY GNSS TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Paulo Cesar Lima Segantine

    Full Text Available The correct data processing of GNSS measurements, as well as a correct interpretation of the results are fundamental factors for analysis of quality of land surveying works. In that sense, it is important to keep in mind that, although, the statistical data provided by the majority of commercials software used for GNSS data processing, describes the credibility of the work, they do not have consistent information about the reliability of the processed coordinates. Based on that assumption, this paper proposes a classification table to classify the reliability of baselines obtained through GNSS data processing. As data input, the GNSS measurements were performed during the years 2006 and 2008, considering different seasons of the year, geometric configurations of RBMC stations and baseline lengths. As demonstrated in this paper, parameters as baseline length, ambiguity solution, PDOP value and the precision of horizontal and vertical values of coordinates can be used as reliability parameters. The proposed classification guarantees the requirements of the Brazilian Law N( 10.267/2001 of the National Institute of Colonization and Agrarian Reform (INCRA

  5. Synergic effect of salivary pH baselines and low pH intakes on the force relaxation of orthodontic latex elastics.

    Science.gov (United States)

    Ajami, Shabnam; Farjood, Amin; Zare, Mahbubeh

    2017-01-01

    Latex elastics are still in common use due to their low cost and high flexibility to improve sagittal discrepancies or interdigitation of teeth. Mechanical properties of elastics are influenced by several environmental factors such as pH changes. This study evaluated similar latex elastics to define the influence of synergic effect of intermittent low pH and various baselines pH of saliva. Four groups of latex elastics (3-M Unitek, 3/16 inch) were tested ( n = 15 in each group). Two groups of elastics were immersed in two tanks of artificial saliva with different pH levels of 7 and 5, and two groups were immersed in two tanks of artificial saliva with intermittent drop of pH to 4. The force was measured when the elastics were stretched to 25 mm. These measurements were taken in 0, 4, 8, 12, 24, 36, and 48 h for each group. Repeated measures analysis of variance (RMANOVA) and post-hoc Tukey's test were used to assess the findings. The level of significance was 0.05%. The interaction between pH and time analyzed with RMANOVA showed no significant differences ( P > 0.05) except in 36 h ( P = 0.014). The Tukey's analysis showed that each comparison between any two groups did not indicate significant differences ( P > 0.05) except between Groups 1 and 3 and between Groups 2 and 3 ( P pH and force degradation in latex elastic band except in 36 h.

  6. Hanford Site technical baseline database. Revision 1

    International Nuclear Information System (INIS)

    Porter, P.E.

    1995-01-01

    This report lists the Hanford specific files (Table 1) that make up the Hanford Site Technical Baseline Database. Table 2 includes the delta files that delineate the differences between this revision and revision 0 of the Hanford Site Technical Baseline Database. This information is being managed and maintained on the Hanford RDD-100 System, which uses the capabilities of RDD-100, a systems engineering software system of Ascent Logic Corporation (ALC). This revision of the Hanford Site Technical Baseline Database uses RDD-100 version 3.0.2.2 (see Table 3). Directories reflect those controlled by the Hanford RDD-100 System Administrator. Table 4 provides information regarding the platform. A cassette tape containing the Hanford Site Technical Baseline Database is available

  7. Baseline and Target Values for PV Forecasts: Toward Improved Solar Power Forecasting: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jie; Hodge, Bri-Mathias; Lu, Siyuan; Hamann, Hendrik F.; Lehman, Brad; Simmons, Joseph; Campos, Edwin; Banunarayanan, Venkat

    2015-08-05

    Accurate solar power forecasting allows utilities to get the most out of the solar resources on their systems. To truly measure the improvements that any new solar forecasting methods can provide, it is important to first develop (or determine) baseline and target solar forecasting at different spatial and temporal scales. This paper aims to develop baseline and target values for solar forecasting metrics. These were informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of solar power output. forecasting metrics. These were informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of solar power output.

  8. Stratum corneum cytokines and skin irritation response to sodium lauryl sulfate.

    Science.gov (United States)

    De Jongh, Cindy M; Verberk, Maarten M; Withagen, Carien E T; Jacobs, John J L; Rustemeyer, Thomas; Kezic, Sanja

    2006-06-01

    Little is known about cytokines involved in chronic irritant contact dermatitis. Individual cytokine profiles might explain at least part of the differences in the individual response to irritation. Our objective was to investigate the relation between baseline stratum corneum (SC) cytokine levels and the skin response to a single and a repeated irritation test. This study also aimed to determine changes in SC cytokine levels after repeated irritation. Transepidermal water loss (TEWL) and erythema were measured in 20 volunteers after single 24-hr exposure to 1% sodium lauryl sulfate (SLS), and during and after repeated exposure to 0.1% SLS over a 3-week period. SC cytokine levels were measured from an unexposed skin site and from the repeatedly exposed site. Interleukin (IL)-1alpha decreased by 30% after repeated exposure, while IL-1RA increased 10-fold and IL-8 increased fourfold. Baseline IL-1RA and IL-8 values were predictors of TEWL and erythema after single exposure (r = 0.55-0.61). 6 subjects showed barrier recovery during repeated exposure. Baseline IL-1RA and IL-8 levels are likely to be indicators of higher skin irritability after single exposure to SLS. Barrier repair in some of the subjects might explain the lack of agreement between the TEWL response after single and repeated irritation.

  9. Comparison of Three Methods Estimating Baseline Creatinine For Acute Kidney Injury in Hospitalized Patients: a Multicentre Survey in Third-Level Urban Hospitals of China.

    Science.gov (United States)

    Lang, Xia-Bing; Yang, Yi; Yang, Ju-Rong; Wan, Jian-Xin; Yu, Sheng-Qiang; Cui, Jiong; Tang, Xiao-Jing; Chen, Jianghua

    2018-01-01

    A lack of baseline serum creatinine (SCr) data leads to underestimation of the burden caused by acute kidney injury (AKI) in developing countries. The goal of this study was to investigate the effects of various baseline SCr analysis methods on the current diagnosis of AKI in hospitalized patients. Patients with at least one SCr value during their hospital stay between January 1, 2011 and December 31, 2012 were retrospectively included in the study. The baseline SCr was determined either by the minimum SCr (SCrMIN) or the estimated SCr using the MDRD formula (SCrGFR-75). We also used the dynamic baseline SCr (SCrdynamic) in accordance with the 7 day/48 hour time window. AKI was defined based on the KDIGO SCr criteria. Of 562,733 hospitalized patients, 350,458 (62.3%) had at least one SCr determination, and 146,185 (26.0%) had repeat SCr tests. AKI was diagnosed in 13,883 (2.5%) patients using the SCrMIN, 21,281 (3.8%) using the SCrGFR-75 and 9,288 (1.7%) using the SCrdynamic. Compared with the non-AKI patients, AKI patients had a higher in-hospital mortality rate regardless of the baseline SCr analysis method. Because of the scarcity of SCr data, imputation of the baseline SCr is necessary to remedy the missing data. The detection rate of AKI varies depending on the different imputation methods. SCrGFR-75 can identify more AKI cases than the other two methods. © 2018 The Author(s). Published by S. Karger AG, Basel.

  10. Comparison of Three Methods Estimating Baseline Creatinine For Acute Kidney Injury in Hospitalized Patients: a Multicentre Survey in Third-Level Urban Hospitals of China

    Directory of Open Access Journals (Sweden)

    Xia-bing Lang

    2018-02-01

    Full Text Available Background/Aims: A lack of baseline serum creatinine (SCr data leads to underestimation of the burden caused by acute kidney injury (AKI in developing countries. The goal of this study was to investigate the effects of various baseline SCr analysis methods on the current diagnosis of AKI in hospitalized patients. Methods: Patients with at least one SCr value during their hospital stay between January 1, 2011 and December 31, 2012 were retrospectively included in the study. The baseline SCr was determined either by the minimum SCr (SCrMIN or the estimated SCr using the MDRD formula (SCrGFR-75. We also used the dynamic baseline SCr (SCrdynamic in accordance with the 7 day/48 hour time window. AKI was defined based on the KDIGO SCr criteria. Results: Of 562,733 hospitalized patients, 350,458 (62.3% had at least one SCr determination, and 146,185 (26.0% had repeat SCr tests. AKI was diagnosed in 13,883 (2.5% patients using the SCrMIN, 21,281 (3.8% using the SCrGFR-75 and 9,288 (1.7% using the SCrdynamic. Compared with the non-AKI patients, AKI patients had a higher in-hospital mortality rate regardless of the baseline SCr analysis method. Conclusions: Because of the scarcity of SCr data, imputation of the baseline SCr is necessary to remedy the missing data. The detection rate of AKI varies depending on the different imputation methods. SCrGFR-75 can identify more AKI cases than the other two methods.

  11. Baseline strength can influence the ability of salivary free testosterone to predict squat and sprinting performance.

    Science.gov (United States)

    Crewther, Blair T; Cook, Christian J; Gaviglio, Chris M; Kilduff, Liam P; Drawer, Scott

    2012-01-01

    The objective of this study was to determine if salivary free testosterone can predict an athlete's performance during back squats and sprints over time and the influence baseline strength on this relationship. Ten weight-trained male athletes were divided into 2 groups based on their 1 repetition maximum (1RM) squats, good squatters (1RM > 2.0 × body weight, n = 5) and average squatters (1RM squat 1RM and 10-m sprint times on 10 separate occasions over a 40-day period. A saliva sample was collected before testing and assayed for free testosterone and cortisol. The pooled testosterone correlations were strong and significant in the good squatters (r = 0.92 for squats, r = -0.87 for sprints, p squats, r = -0.18 for sprints). Cortisol showed no significant correlations with 1RM squat and 10-m sprint performance, and no differences were identified between the 2 squatting groups. In summary, these results suggest that free testosterone is a strong individual predictor of squat and sprinting performance in individuals with relatively high strength levels but a poor predictor in less strong individuals. This information can assist coaches, trainers, and performance scientists working with stronger weight-trained athletes, for example, the preworkout measurement of free testosterone could indicate likely training outcomes or a readiness to train at a certain intensity level, especially if real-time measurements are made. Our results also highlight the need to separate group and individual hormonal data during the repeated testing of athletes with variable strength levels.

  12. Test–retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects

    International Nuclear Information System (INIS)

    Cutajar, Marica; Clayden, Jonathan D.; Clark, Christopher A.; Gordon, Isky

    2011-01-01

    Purpose: This study assessed test–retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Materials and methods: Seven healthy volunteers (age range, 19–31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR = 730 ms, TE = 73 ms and 2 b-values (0 and 400 s mm −2 ). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Results: Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Conclusion: Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable.

  13. In situ detection of tandem DNA repeat length

    Energy Technology Data Exchange (ETDEWEB)

    Yaar, R.; Szafranski, P.; Cantor, C.R.; Smith, C.L. [Boston Univ., MA (United States)

    1996-11-01

    A simple method for scoring short tandem DNA repeats is presented. An oligonucleotide target, containing tandem repeats embedded in a unique sequence, was hybridized to a set of complementary probes, containing tandem repeats of known lengths. Single-stranded loop structures formed on duplexes containing a mismatched (different) number of tandem repeats. No loop structure formed on duplexes containing a matched (identical) number of tandem repeats. The matched and mismatched loop structures were enzymatically distinguished and differentially labeled by treatment with S1 nuclease and the Klenow fragment of DNA polymerase. 7 refs., 4 figs.

  14. 75 FR 66748 - Notice of Baseline Filings

    Science.gov (United States)

    2010-10-29

    ...- 000] Notice of Baseline Filings October 22, 2010. ONEOK Gas Transportation, L.L.C Docket No. PR11-68... above submitted a revised baseline filing of their Statement of Operating Conditions for services...

  15. High SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging

    Science.gov (United States)

    Motosugi, Utaroh; Hernando, Diego; Wiens, Curtis; Bannas, Peter; Reeder, Scott. B

    2017-01-01

    Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments. Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols. Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI. PMID:28190853

  16. Thermal, cardiac and adrenergic responses to repeated local cooling.

    Science.gov (United States)

    Janský, L; Matousková, E; Vávra, V; Vybíral, S; Janský, P; Jandová, D; Knízková, I; Kunc, P

    2006-01-01

    The aim of this study was to ascertain whether repeated local cooling induces the same or different adaptational responses as repeated whole body cooling. Repeated cooling of the legs (immersion into 12 degrees C water up to the knees for 30 min, 20 times during 4 weeks = local cold adaptation - LCA) attenuated the initial increase in heart rate and blood pressure currently observed in control subjects immersed in cold water up to the knees. After LCA the initial skin temperature decrease tended to be lower, indicating reduced vasoconstriction. Heart rate and systolic blood pressure appeared to be generally lower during rest and during the time course of cooling in LCA humans, when compared to controls. All these changes seem to indicate attenuation of the sympathetic tone. In contrast, the sustained skin temperature in different areas of the body (finger, palm, forearm, thigh, chest) appeared to be generally lower in LCA subjects than in controls (except for temperatures on the forehead). Plasma levels of catecholamines (measured 20 and 40 min after the onset of cooling) were also not influenced by local cold adaptation. Locally cold adapted subjects, when exposed to whole body cold water immersion test, showed no change in the threshold temperature for induction of cold thermogenesis. This indicates that the hypothermic type of cold adaptation, typically occurring after systemic cold adaptation, does not appear after local cold adaptation of the intensity used. It is concluded that in humans the cold adaptation due to repeated local cooling of legs induces different physiological changes than systemic cold adaptation.

  17. A high stability and repeatability electrochemical scanning tunneling microscope.

    Science.gov (United States)

    Xia, Zhigang; Wang, Jihao; Hou, Yubin; Lu, Qingyou

    2014-12-01

    We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO4(2-) image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.

  18. Effects of adjunctive N-acetylcysteine on depressive symptoms: Modulation by baseline high-sensitivity C-reactive protein.

    Science.gov (United States)

    Porcu, Mauro; Urbano, Mariana Ragassi; Verri, Waldiceu A; Barbosa, Decio Sabbatini; Baracat, Marcela; Vargas, Heber Odebrecht; Machado, Regina Célia Bueno Rezende; Pescim, Rodrigo Rossetto; Nunes, Sandra Odebrecht Vargas

    2018-05-01

    Outcomes in a RCTs of 12 weeks of theclinical efficacy of N-acetylcysteine (NAC) as an adjunctive treatment on depression and anxiety symptoms and its effects on high-sensitivity C-reactive protein (hs-CRP) levels. A wide array of measures were made. The 17-item version of the Hamilton Depression Rating Scale (HDRS17); the Hamilton Anxiety Rating Scale (HAM-A); Sheehan Disability Scale; Quality of Life; Clinical Global Impression (CGI); anthropometrics measures; and vital signs and biochemical laboratory. There were no significant differences among the groups regarding demographic, clinical features, use of medication, metabolic syndrome and comorbidities. From baseline to week 12, individuals receiving NAC, versus placebo, had a statistically significant reduction in depressive symptoms on HDRS 17 (p  3 mg/L at baseline. Individuals receiving NAC with baseline levels of hs-CRP > 3 mg/L, had more significant reduction in uric acid levels compared to individuals with baseline levels of hs-CRP ≤ 3 mg/L on week 12. Participants receiving placebogained significantly more weight during the 12 weeks for baseline levels of hs-CRP ≤ 3 mg/L and hs-CRP > 3 mg/L, and individuals receiving NAC in both groups did not have significant weight change during the 12 weeks. No individuals were withdrawn from the study because of adverse event. NAC group exhibited significantly greater reduction on hs-CRP levels than placebo group from baseline to week 12. clinicaltrials.gov Identifier; NCT02252341. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. 2016 Annual Technology Baseline (ATB) - Webinar Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley; Kurup, Parthiv; Hand, Maureen; Feldman, David; Sigrin, Benjamin; Lantz, Eric; Stehly, Tyler; Augustine, Chad; Turchi, Craig; Porro, Gian; O' Connor, Patrick; Waldoch, Connor

    2016-09-13

    This deck was presented for the 2016 Annual Technology Baseline Webinar. The presentation describes the Annual Technology Baseline, which is a compilation of current and future cost and performance data for electricity generation technologies.

  20. Baseline response rates affect resistance to change.

    Science.gov (United States)

    Kuroda, Toshikazu; Cook, James E; Lattal, Kennon A

    2018-01-01

    The effect of response rates on resistance to change, measured as resistance to extinction, was examined in two experiments. In Experiment 1, responding in transition from a variable-ratio schedule and its yoked-interval counterpart to extinction was compared with pigeons. Following training on a multiple variable-ratio yoked-interval schedule of reinforcement, in which response rates were higher in the former component, reinforcement was removed from both components during a single extended extinction session. Resistance to extinction in the yoked-interval component was always either greater or equal to that in the variable-ratio component. In Experiment 2, resistance to extinction was compared for two groups of rats that exhibited either high or low response rates when maintained on identical variable-interval schedules. Resistance to extinction was greater for the lower-response-rate group. These results suggest that baseline response rate can contribute to resistance to change. Such effects, however, can only be revealed when baseline response rate and reinforcement rate are disentangled (Experiments 1 and 2) from the more usual circumstance where the two covary. Furthermore, they are more cleanly revealed when the programmed contingencies controlling high and low response rates are identical, as in Experiment 2. © 2017 Society for the Experimental Analysis of Behavior.

  1. The repeatability of left ventricular volume assessment by a new ambulatory radionuclide monitoring system during head-up tilt

    International Nuclear Information System (INIS)

    Takase, Bonpei; Hosaka, Haruhiko; Kitamura, Katsuhiro

    2001-01-01

    The precise measurement of changes in left ventricular volume is important to elucidate the mechanisms of neurally mediated syncope. This study was conducted to determine whether or not a brand-new ambulatory radionuclide monitoring system (C-VEST system) can be clinically used to easily and precisely measure left ventricular volume and function in tilt testing. To assess the repeatability of the C-VEST system, 12 healthy volunteers (mean age 24±4 years old) underwent 20 minute head-up tilt testing and we measured the temporal changes in left ventricular volume and ejection fraction twice a day (first and second studies). To investigate the changes in the C-VEST measurements and the detector position in the first and second studies, tilt testing was performed with an 80-degree passive tilt, which is the same as the standard procedure used in diagnosing neurally mediated syncope. The coefficient of repeatability for both the C-VEST and detector position was well within the clinical range (coefficient of repeatability in left ventricular volume ranged from 1.7 to 2.8; coefficient of repeatability in the detector position ranged from 2.3 to 3.1). Precise evaluation of the left ventricular volume can be achieved by an ambulatory radionuclide monitoring system in tilt testing. (author)

  2. Vascular Function at Baseline in the Hemodialysis Fistula Maturation Study

    OpenAIRE

    Dember, Laura M.; Imrey, Peter B.; Duess, Mai?Ann; Hamburg, Naomi M.; Larive, Brett; Radeva, Milena; Himmelfarb, Jonathan; Kraiss, Larry W.; Kusek, John W.; Roy?Chaudhury, Prabir; Terry, Christi M.; Vazquez, Miguel A.; Vongpatanasin, Wanpen; Beck, Gerald J.; Vita, Joseph A.

    2016-01-01

    Background End?stage renal disease is accompanied by functional and structural vascular abnormalities. The objective of this study was to characterize vascular function in a large cohort of patients with end?stage renal disease, using noninvasive physiological measurements, and to correlate function with demographic and clinical factors. Methods and Results We analyzed cross?sectional baseline data from the Hemodialysis Fistula Maturation Study, a multicenter prospective observational cohort ...

  3. How do repeat suicide attempters differ from first timers? An exploratory record based analysis

    Directory of Open Access Journals (Sweden)

    Vikas Menon

    2016-01-01

    Full Text Available Background: Evidence indicates that repeat suicide attempters, as a group, may differ from 1st time attempters. The identification of repeat attempters is a powerful but underutilized clinical variable. Aims: In this research, we aimed to compare individuals with lifetime histories of multiple attempts with 1st time attempters to identify factors predictive of repeat attempts. Setting and Design: This was a retrospective record based study carried out at a teaching cum Tertiary Care Hospital in South India. Methods: Relevant data was extracted from the clinical records of 1st time attempters (n = 362 and repeat attempters (n = 61 presenting to a single Tertiary Care Center over a 4½ year period. They were compared on various sociodemographic and clinical parameters. The clinical measures included Presumptive Stressful Life Events Scale, Beck Hopelessness Scale, Coping Strategies Inventory – Short Form, and the Global Assessment of Functioning Scale. Statistical Analysis Used: First time attempters and repeaters were compared using appropriate inferential statistics. Logistic regression was used to identify independent predictors of repeat attempts. Results: The two groups did not significantly differ on sociodemographic characteristics. Repeat attempters were more likely to have given prior hints about their act (χ2 = 4.500, P = 0.034. In the final regression model, beck hopelessness score emerged as a significant predictor of repeat suicide attempts (odds ratio = 1.064, P = 0.020. Conclusion: Among suicide attempters presenting to the hospital, the presence of hopelessness is a predictor of repeat suicide attempts, independent of clinical depression. This highlights the importance of considering hopelessness in the assessment of suicidality with a view to minimize the risk of future attempts.

  4. Baseline toxicity of a chlorobenzene mixture and total body residues measured and estimated with solid-phase microextraction

    NARCIS (Netherlands)

    Leslie, H.A.; Hermens, J.L.; Kraak, M.H.S.

    2004-01-01

    Body residues of compounds with a narcotic mode of action that exceed critical levels result in baseline toxicity in organisms. Previous studies have shown that internal concentrations in organisms also can be estimated by way of passive sampling. In this experiment, solid-phase microextraction

  5. Baseline PSA in a Spanish male population aged 40-49 years anticipates detection of prostate cancer.

    Science.gov (United States)

    Angulo, J C; Viñas, M A; Gimbernat, H; Fata, F Ramón de; Granados, R; Luján, M

    2015-12-01

    We researched the usefulness of optimizing prostate cancer (PC) screening in our community using baseline PSA readings in men between 40-49 years of age. A retrospective study was performed that analyzed baseline PSA in the fifth decade of life and its ability to predict the development of PC in a population of Madrid (Spain). An ROC curve was created and a cutoff was proposed. We compared the evolution of PSA from baseline in patients with consecutive readings using the Friedman test. We established baseline PSA ranges with different risks of developing cancer and assessed the diagnostic utility of the annual PSA velocity (PSAV) in this population. Some 4,304 men aged 40-49 years underwent opportunistic screening over the course of 17 years, with at least one serum PSA reading (6,001 readings) and a mean follow-up of 57.1±36.8 months. Of these, 768 underwent biopsy of some organ, and 104 underwent prostate biopsy. Fourteen patients (.33%) were diagnosed with prostate cancer. The median baseline PSA was .74 (.01-58.5) ng/mL for patients without PC and 4.21 (.76-47.4) ng/mL for those with PC. The median time from the reading to diagnosis was 26.8 (1.5-143.8) months. The optimal cutoff for detecting PC was 1.9ng/mL (sensitivity, 92.86%; specificity, 92.54%; PPV, 3.9%; NPV, 99.97%), and the area under the curve was 92.8%. In terms of the repeated reading, the evolution of the PSA showed no statistically significant differences between the patients without cancer (p=.56) and those with cancer (P=.64). However, a PSAV value >.3ng/mL/year revealed high specificity for detecting cancer in this population. A baseline PSA level ≥1.9ng/mL in Spanish men aged 40-49 years predicted the development of PC. This value could therefore be of use for opportunistic screening at an early age. An appropriate follow-up adapted to the risk of this population needs to be defined, but an annual PSAV ≥.3ng/mL/year appears of use for reaching an early diagnosis. Copyright © 2015 AEU

  6. Associations between baseline allergens and polysensitization

    DEFF Research Database (Denmark)

    Carlsen, B.C.; Menne, T.; Johansen, J.D.

    2008-01-01

    Background: Identification of patients at risk of developing polysensitization is not possible at present. An association between weak sensitizers and polysensitization has been hypothesized. Objectives: To examine associations of 21 allergens in the European baseline series to polysensitization....... Patients/Methods: From a database-based study with 14 998 patients patch tested with the European baseline series between 1985 and 2005, a group of 759 (5.1%) patients were polysensitized. Odds ratios were calculated to determine the relative contribution of each allergen to polysensitization. Results...... denominator for the association between the allergens and the polysensitization was apparent, and any association, whether positive or negative, was relatively low. Based on these results, sensitization to specific baseline allergens cannot be used as risk indicators for polysensitization Udgivelsesdato: 2008...

  7. Associations between baseline allergens and polysensitization

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Menné, Torkil; Johansen, Jeanne Duus

    2008-01-01

    BACKGROUND: Identification of patients at risk of developing polysensitization is not possible at present. An association between weak sensitizers and polysensitization has been hypothesized. OBJECTIVES: To examine associations of 21 allergens in the European baseline series to polysensitization....... PATIENTS/METHODS: From a database-based study with 14 998 patients patch tested with the European baseline series between 1985 and 2005, a group of 759 (5.1%) patients were polysensitized. Odds ratios were calculated to determine the relative contribution of each allergen to polysensitization. RESULTS...... denominator for the association between the allergens and the polysensitization was apparent, and any association, whether positive or negative, was relatively low. Based on these results, sensitization to specific baseline allergens cannot be used as risk indicators for polysensitization....

  8. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Directory of Open Access Journals (Sweden)

    Katharine Reed

    Full Text Available Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run and self-reported physical activity (PAQ-A in 11 and 12 year olds (n = 75. Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74, = 12.2, p<0.001, for the increase in self-esteem following exercise but there was no condition by exercise interaction (F (1,74, = 0.13, p = 0.72. There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04 between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55. Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  9. TWRS technical baseline database manager definition document

    International Nuclear Information System (INIS)

    Acree, C.D.

    1997-01-01

    This document serves as a guide for using the TWRS Technical Baseline Database Management Systems Engineering (SE) support tool in performing SE activities for the Tank Waste Remediation System (TWRS). This document will provide a consistent interpretation of the relationships between the TWRS Technical Baseline Database Management software and the present TWRS SE practices. The Database Manager currently utilized is the RDD-1000 System manufactured by the Ascent Logic Corporation. In other documents, the term RDD-1000 may be used interchangeably with TWRS Technical Baseline Database Manager

  10. Hybrid FRC under repeated loading

    International Nuclear Information System (INIS)

    Komlos, K.; Babal, B.; Nuernbergerova, T.

    1993-01-01

    Fibre reinforced concretes (FRC) containing several volume fractions in different ratios of two types of fibres - polypropylene and steel, were tested under repeated loading. Mechanical properties of specimens - cubes 150/150/150 mm (for compressive strength), prisms 100/100/400 (for flexural strength), short cylinders 150/60 mm (for impact strength) have been experimentally investigated before and after cyclic loading at the age of 28 days curing time. Mix proportions were designed after DIN 1045 with max. aggregate size 8 mm and grading curve B 8. Portland Cement PC 400 in the amount of 450 kg. m -3 was applied and W/C ratio 0.55. Workability of mixes was measured by Vebe method and regulated by plasticizing admixture Ligoplast Na. Maximum hybrid fibre volume fraction (polypropylene + steel) was 1.0%. Dynamic forces generated in Schenck testing machine with frequency 16 Hz had sinusoidal wave form varying between 0.7 and 0.1 of static mechanical characteristics. The number of cycles in all tests was 10 5 . The residual MOR at static four point bending test and working diagram force-deflection was carried out as well. The impact properties after repeated loading in compression were tested by means of falling weight test. Relationships between composition of fibre composites with different combination of polypropylene (0.2, 0.3, 0.5% by volume) and steel (0.5, 0.7, and 0.8% by volume) fibre content were obtained and technological properties of mixes as well. (author)

  11. Control of coercive field in lithium niobate crystals with repeated polarization reversal

    International Nuclear Information System (INIS)

    Ro, Jung Hoon; Jeong, Doun; Park, Taeyong; Kim, Chulhan; Kwon, Soon-Bok; Cha, Myoungsik; Choi, Byeong Cheol; Yu, Nanei; Kurimura, Sunao; Jeon, Gyerok

    2005-01-01

    In this study, the amount of decrease in coercive field of congruent lithium niobate during repeated poling and back-poling was measured. The polarization is reversed in 300 ms and then back-poled during the rest period. The coercive field can be decreased around 1 kV/mm with a repeated poling interval of 5 s. As the interval prolonged, the poling field decrease became smaller, and a stretched exponential function is suggested for the experimental fitting resulting in a set of meaningful parameters. These values are essential for the design of high quality domain engineering

  12. Digital repeat analysis; setup and operation.

    Science.gov (United States)

    Nol, J; Isouard, G; Mirecki, J

    2006-06-01

    Since the emergence of digital imaging, there have been questions about the necessity of continuing reject analysis programs in imaging departments to evaluate performance and quality. As a marketing strategy, most suppliers of digital technology focus on the supremacy of the technology and its ability to reduce the number of repeats, resulting in less radiation doses given to patients and increased productivity in the department. On the other hand, quality assurance radiographers and radiologists believe that repeats are mainly related to positioning skills, and repeat analysis is the main tool to plan training needs to up-skill radiographers. A comparative study between conventional and digital imaging was undertaken to compare outcomes and evaluate the need for reject analysis. However, digital technology still being at its early development stages, setting a credible reject analysis program became the major task of the study. It took the department, with the help of the suppliers of the computed radiography reader and the picture archiving and communication system, over 2 years of software enhancement to build a reliable digital repeat analysis system. The results were supportive of both philosophies; the number of repeats as a result of exposure factors was reduced dramatically; however, the percentage of repeats as a result of positioning skills was slightly on the increase for the simple reason that some rejects in the conventional system qualifying for both exposure and positioning errors were classified as exposure error. The ability of digitally adjusting dark or light images reclassified some of those images as positioning errors.

  13. Autonomous and controlled motivation for eating disorders treatment: baseline predictors and relationship to treatment outcome.

    Science.gov (United States)

    Carter, Jacqueline C; Kelly, Allison C

    2015-03-01

    This study aimed to identify baseline predictors of autonomous and controlled motivation for treatment (ACMT) in a transdiagnostic eating disorder sample, and to examine whether ACMT at baseline predicted change in eating disorder psychopathology during treatment. Participants were 97 individuals who met DSM-IV-TR criteria for an eating disorder and were admitted to a specialized intensive treatment programme. Self-report measures of eating disorder psychopathology, ACMT, and various psychosocial variables were completed at the start of treatment. A subset of these measures was completed again after 3, 6, 9, and 12 weeks of treatment. Multiple regression analyses showed that baseline autonomous motivation was higher among patients who reported more self-compassion and more received social support, whereas the only baseline predictor of controlled motivation was shame. Multilevel modelling revealed that higher baseline autonomous motivation predicted faster decreases in global eating disorder psychopathology, whereas the level of controlled motivation at baseline did not. The current findings suggest that developing interventions designed to foster autonomous motivation specifically and employing autonomy supportive strategies may be important to improving eating disorders treatment outcome. The findings of this study suggest that developing motivational interventions that focus specifically on enhancing autonomous motivation for change may be important for promoting eating disorder recovery. Our results lend support for the use of autonomy supportive strategies to strengthen personally meaningful reasons to achieve freely chosen change goals in order to enhance treatment for eating disorders. One study limitation is that there were no follow-up assessments beyond the 12-week study and we therefore do not know whether the relationships that we observed persisted after treatment. Another limitation is that this was a correlational study and it is therefore important

  14. Impact of Advanced Practice Registered Nurses on Quality Measures: The Missouri Quality Initiative Experience.

    Science.gov (United States)

    Rantz, Marilyn J; Popejoy, Lori; Vogelsmeier, Amy; Galambos, Colleen; Alexander, Greg; Flesner, Marcia; Murray, Cathy; Crecelius, Charles; Ge, Bin; Petroski, Gregory

    2018-06-01

    The purpose of this article is to review the impact of advanced practice registered nurses (APRNs) on the quality measure (QM) scores of the 16 participating nursing homes of the Missouri Quality Initiative (MOQI) intervention. The MOQI was one of 7 program sites in the US, with specific interventions unique to each site tested for the Centers for Medicaid and Medicare Services Innovations Center. While the goals of the MOQI for long-stay nursing home residents did not specifically include improvement of the QM scores, it was anticipated that improvement most likely would occur. Primary goals of the MOQI were to reduce the frequency of avoidable hospital admissions and readmissions; improve resident health outcomes; improve the process of transitioning between inpatient hospitals and nursing facilities; and reduce overall healthcare spending without restricting access to care or choice of providers. A 2-group comparison analysis was conducted using statewide QMs; a matched comparison group was selected from facilities in the same counties as the intervention homes, similar baseline QM scores, similar size and ownership. MOQI nursing homes each had an APRN embedded full-time to improve care and help the facility achieve MOQI goals. Part of their clinical work with residents and staff was to focus on quality improvement strategies with potential to influence healthcare outcomes. Trajectories of QM scores for the MOQI intervention nursing homes and matched comparison group homes were tested with nonparametric tests to examine for change in the desired direction between the 2 groups from baseline to 36 months. A composite QM score for each facility was constructed, and baseline to 36-month average change scores were examined using nonparametric tests. Then, adjusting for baseline, a repeated measures analysis using analysis of covariance as conducted. Composite QM scores of the APRN intervention group were significantly better (P = .025) than the comparison group

  15. The effect of technical replicate (repeats) on Nix Pro Color Sensor™ measurement precision for meat: A case-study on aged beef colour stability.

    Science.gov (United States)

    Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L

    2018-01-01

    The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  16. Business-as-Unusual: Existing policies in energy model baselines

    International Nuclear Information System (INIS)

    Strachan, Neil

    2011-01-01

    Baselines are generally accepted as a key input assumption in long-term energy modelling, but energy models have traditionally been poor on identifying baselines assumptions. Notably, transparency on the current policy content of model baselines is now especially critical as long-term climate mitigation policies have been underway for a number of years. This paper argues that the range of existing energy and emissions policies are an integral part of any long-term baseline, and hence already represent a 'with-policy' baseline, termed here a Business-as-Unusual (BAuU). Crucially, existing energy policies are not a sunk effort; as impacts of existing policy initiatives are targeted at future years, they may be revised through iterative policy making, and their quantitative effectiveness requires ex-post verification. To assess the long-term role of existing policies in energy modelling, currently identified UK policies are explicitly stripped out of the UK MARKAL Elastic Demand (MED) optimisation energy system model, to generate a BAuU (with-policy) and a REF (without policy) baseline. In terms of long-term mitigation costs, policy-baseline assumptions are comparable to another key exogenous modelling assumption - that of global fossil fuel prices. Therefore, best practice in energy modelling would be to have both a no-policy reference baseline, and a current policy reference baseline (BAuU). At a minimum, energy modelling studies should have a transparent assessment of the current policy contained within the baseline. Clearly identifying and comparing policy-baseline assumptions are required for cost effective and objective policy making, otherwise energy models will underestimate the true cost of long-term emissions reductions.

  17. Evidence of radiation-induced reduction of height and body weight from repeated measurements of adults exposed in childhood to the atomic bombs

    International Nuclear Information System (INIS)

    Otake, Masanori; Funamoto, Sachiyo; Fujikoshi, Yasunori; Schull, W.J.

    1994-01-01

    Reduction of growth from exposure to atomic bomb radiation has been examined using individuals under 10 years old at the time of the bombing (ATB) and a growth curve analysis based on measurements of height and weight made in the course of the 4th-7th cycles of the Adult Health Study examinations (1964-1972). As expected, the largest difference in growth to emerge is between males and females. However, a highly significant reduction of growth associated with dose (DS86) was observed among those survivors for whom four repeated measurements of height and weight were available. Longitudinal analysis of a more extended data set (n = 821), using expected values based on simple linear regression models fitted to the three available sets of measurements of height and weight on the 254 individuals with a missing measurement, also indicates a significant radiation-related growth reduction. The possible contribution of such factors as poor nutrition and disruption of normal family life in the years immediately after the war is difficult to evaluate, but the effects of socioeconomic factors on the analysis of these data are discussed. 33 refs., 5 figs., 3 tabs

  18. Pakistan, Sindh Province - Baseline Indicators System : Baseline Procurement Performance Assessment Report

    OpenAIRE

    World Bank

    2009-01-01

    This document provides an assessment of the public procurement system in Sindh province using the baseline indicators system developed by the Development Assistance Committee of the Organization for Economic Cooperation and Development (OECD-DAC). This assessment, interviews and discussions were held with stakeholders from the public and private sectors as well as civil society. Developing...

  19. Life Support Baseline Values and Assumptions Document

    Science.gov (United States)

    Anderson, Molly S.; Ewert, Michael K.; Keener, John F.

    2018-01-01

    The Baseline Values and Assumptions Document (BVAD) provides analysts, modelers, and other life support researchers with a common set of values and assumptions which can be used as a baseline in their studies. This baseline, in turn, provides a common point of origin from which many studies in the community may depart, making research results easier to compare and providing researchers with reasonable values to assume for areas outside their experience. This document identifies many specific physical quantities that define life support systems, serving as a general reference for spacecraft life support system technology developers.

  20. Baseline distortion effect on gamma-ray pulse-height spectra in neutron capture experiments

    International Nuclear Information System (INIS)

    Laptev, A.; Harada, H.; Nakamura, S.; Hori, J.; Igashira, M.; Ohsaki, T.; Ohgama, K.

    2005-01-01

    A baseline distortion effect due to gamma-flash at neutron time-of-flight measurement using a pulse neutron source has been investigated. Pulses from C 6 D 6 detectors accumulated by flash-ADC were processed with both standard analog-to-digital converter (ADC) and flash-ADC operational modes. A correction factor of gamma-ray yields, due to baseline shift, was quantitatively obtained by comparing the pulse height spectra of the two data-taking modes. The magnitude of the correction factor depends on the time after gamma-flash and has complex time dependence with a changing sign