WorldWideScience

Sample records for axonopodis pv malvacearum

  1. A Semi-Selective agar medium to detect the presence of Xanthomonas axonopodis pv. malvacearum in naturally infected cotton seed Meio semi-selectivo para detectar a presença de Xanthomonas axonopodis pv. malvacearum em sementes de algodoeiro naturalmente infetadas

    Directory of Open Access Journals (Sweden)

    Yeshwant R Mehta

    2005-10-01

    Full Text Available A semi-selective agar medium was developed for detection of Xanthomonas axonopodis pv. malvacearum (Xam in cotton (Gossypium hirsutum seed. The basic medium was peptone-sucrose-agar (PSA. Criteria for the semi-selective medium were the typical colony characters of Xam and its pathogenicity on cotton. Several systemic fungicides and antibiotics in different concentrations were tested alone or in combination with others. The final composition of the semi-selective agar medium was established after several attempts in order to inhibit most of the fungal and bacterial saprophytes and favour the development of Xam. It contained PSA + cyclohexamide, cephalexin, pencycuron, triadimenol and tolylfluanid. The bacteria were recovered from naturally infected seeds by the direct plating of 2,000 surface disinfected seeds on the semi-selective medium. The recovery of the pathogen from naturally infected leaf tissues and in dilution plating, on semi-selective medium and on nutrient agar, were comparable. Among the three detection methods tested, the semi-selective medium was found to be the most reliable and quantifiable. Degree of severity of angular leaf spot in the field was not always correlated with the level of infection in the seed. This is the first report of a semi-selective agar medium to detect the presence of Xam in naturally infected cotton seed.Um meio de cultura semi-seletivo foi desenvolvido para detectar Xanthomonas axonopodis pv. malvacearum (Xam em sementes do algodoeiro (Gossypium hirsutum. O meio básico foi peptona-sacarose-ágar (PSA. Os critérios para o meio semi-seletivo foram; as características típicas das colônias de Xam e sua patogenicidade em algodoeiro. Vários fungicidas sistêmicos e antibióticos foram testados sozinhos ou em combinação com outros em diferentes concentrações. A composição final do meio semi-seletivo foi estabelecida após várias tentativas no sentido de inibir a maioria dos fungos e bact

  2. Establishment of an in vitro system for studies on the induced resistance of cotton to Xanthomonas campestris pv. malvacearum Estabelecimento de sistema in vitro para estudos da resistência induzida à Xanthomonas campestris pv. malvacearum em algodoeiro

    Directory of Open Access Journals (Sweden)

    ADILSON KENJI KOBAYASHI

    2000-04-01

    Full Text Available An in vitro system for studying the resistance response of cotton (Gossypium hirsutum L. to Xanthomonas campestris pv. malvacearum was investigated. Cell suspension cultures, established from hypocotyl-derived callus of cotton cultivar 101-102B, were treated with bacterial extracellular polysaccharides (EPS extracted from the incompatible race 18 of X. campestris pv. malvacearum. EPS at 600 mug/mL caused pronounced darkening of the suspension cultures, as indicative of cell death, 48 hours after incubation. Protein electrophoresis analysis of the time course of EPS-treated cells showed differential accumulation of several protein bands after 12-24 hours. The time course of protein accumulation and cell death was consistent with an elicitor-mediated hypersensitive response.Desenvolveu-se um sistema in vitro para estudar a resistência do algodoeiro (Gossypium hirsutum L. à Xanthomonas campestris pv. malvacearum. Foram utilizados calos originados a partir de hipocótilos da cultivar de algodoeiro 101-102B para estabelecer culturas de células em suspensão, as quais foram tratadas com polissacarídeos extracelulares bacterianos (EPS extraídos da raça incompatível 18 de X. campestris pv. malvacearum. O tratamento com EPS, na concentração de 600 mig/mL, causou acentuado escurecimento das culturas em suspensão, indicativo de morte celular, 48 horas após a incubação. A análise temporal do perfil eletroforético de proteínas extraídas das células tratadas com EPS mostrou um acúmulo diferencial de diversas proteínas após 12-24 horas. O acúmulo de proteínas e a morte celular ao longo do período estudado foram consistentes com um padrão de resposta de hipersensibilidade causada por elicitores.

  3. INDUCTION OF SYSTEMIC RESISTANCE BY BIOCONTROL AGENTS AGAINST BACTERIAL BLIGHT OF COTTON CAUSED BY XANTHOMONAS CAMPESTRIS PV. MALVACEARUM

    Directory of Open Access Journals (Sweden)

    Niranjana S. Ramachandrappa

    2013-04-01

    Full Text Available Bioagents such as Trichoderma harzianum, Pseudomonas fluorescens and Bacillus subtilis were isolated from cotton rhizosphere soil and tested individually for their effectiveness in controlling bacterial blight of cotton caused by Xanthomonas campestris pv. malvacearum (Xcm. Talc based formulations were prepared and used for seed treatment at different concentrations for assessing their ability to stimulate plant growth and to control bacterial blight disease. Among bioagents, P. fluorescens and T. harzianum proved to be effective in controlling disease under field conditions.  Other than direct action, these bioagents triggered the defense related enzymes involved in synthesis of phenols. Higher activity of peroxidase, phenylalanine ammonia-lyase, polyphenol oxidase and b-1,3-glucanase was observed in P. fluorescens and T. harzianum treated cotton plants after challenge inoculation with Xcm. Seed treatment with these bioagents enhanced the seed germination and growth parameters against blight disease and they also induced systemic resistance in plant for defense mechanisms. 

  4. CHARACTERIZATION OF XANTHOMONAS AXONOPODIS PV. PUNICAE ISOLATES FROM WESTERN MAHARASHTRA AND THEIR SENSITIVITY TO CHEMICAL TREATMENTS

    OpenAIRE

    K. S. RAGHUWANSHI; B. A. HUJARE; V. P. CHIMOTE; S. G. BORKAR

    2013-01-01

    Bacterial blight of pomegranate caused by Xanthomonas axonopodis pv. punicae is a major biotic constraint inpeninsular India. Field survey was undertaken in the major pomegranate growing regions of Western Maharashtra,which revealed the high prevalence of bacterial blight incidence in Solapur, Sangli and Nashik districts. Fourdifferent isolates of this pathogen were obtained from the highly infected plant materials collected during the fieldsurvey. X. axonopodis pv. punicae was detected from ...

  5. Insights into xanthomonas axonopodis pv. Citri biofilm through proteomics

    KAUST Repository

    Zimaro, Tamara

    2013-08-07

    Background: Xanthomonas axonopodis pv. Citri (X. a. pv. Citri) causes citrus canker that can result in defoliation and premature fruit drop with significant production losses worldwide. Biofilm formation is an important process in bacterial pathogens and several lines of evidence suggest that in X. a. pv. Citri this process is a requirement to achieve maximal virulence since it has a major role in host interactions. In this study, proteomics was used to gain further insights into the functions of biofilms. Results: In order to identify differentially expressed proteins, a comparative proteomic study using 2D difference gel electrophoresis was carried out on X. a. pv. Citri mature biofilm and planktonic cells. The biofilm proteome showed major variations in the composition of outer membrane proteins and receptor or transport proteins. Among them, several porins and TonB-dependent receptor were differentially regulated in the biofilm compared to the planktonic cells, indicating that these proteins may serve in maintaining specific membrane-associated functions including signaling and cellular homeostasis. In biofilms, UDP-glucose dehydrogenase with a major role in exopolysaccharide production and the non-fimbrial adhesin YapH involved in adherence were over-expressed, while a polynucleotide phosphorylase that was demonstrated to negatively control biofilm formation in E. coli was down-regulated. In addition, several proteins involved in protein synthesis, folding and stabilization were up-regulated in biofilms. Interestingly, some proteins related to energy production, such as ATP-synthase were down-regulated in biofilms. Moreover, a number of enzymes of the tricarboxylic acid cycle were differentially expressed. In addition, X. a. pv. Citri biofilms also showed down-regulation of several antioxidant enzymes. The respective gene expression patterns of several identified proteins in both X. a. pv. Citri mature biofilm and planktonic cells were evaluated by

  6. Caracterização de isolados de Xanthomonas axonopodis pv. manihotis = Characterization of isolates of Xanthomonas axonopodis pv. manihotis

    Directory of Open Access Journals (Sweden)

    Roberto Luis Portz

    2006-07-01

    Full Text Available A bacteriose (Xanthomonas axonopodis pv. manihotis e a doenca de maior importancia economica na cultura da mandioca. Para estudar a variabilidade genetica desta bacteria no Oeste do Parana, foram realizados levantamentos em Entre Rios do Oeste, Marechal Candido Rondon, Mercedes, Missal, Nova Santa Rosa e Pato Bragado. Os isolados foram caracterizados em relacao a atividade de amilase, ƒ¿ e ƒÀ-esterase e agressividade. Dos 61 materiais vegetais coletados, obtiveram-se 19 isolados da bacteria, com maior incidencia para variedades de mesa em relacao aqueles para industria. Manivas provenientes de Pato Bragado, Entre Rios do Oeste e Mercedes apresentaram incidencias de 10, 27 e 10%, respectivamente, valores inferiores aos de Marechal Candido Rondon (50% e Nova Santa Rosa (58%. Os isolados foram agrupados em cinco, seis e 12 grupos em relacao a capacidade amilolitica, agressividade e isoenzimas de esterase, respectivamente. Nao houve relacao entre atividade de amilase e agressividade. Isolados de Marechal Candido Rondon foram mais agressivos que os provenientes das outras regioes. O agrupamento com base em esterase permitiu verificar que isolados provenientes de Entre Rios do Oeste, Nova Santa Rosa e Mercedes apresentaram alto grau de similaridade. Estes resultados indicam haver diferenciacaoentre os isolados da bacteria presentes nos municipios amostrados.The bacterial blight (Xanthomonas axonopodis pv. manihotis is the most important disease of cassava. To study the genetic variability of pathogen in the West of Parana, a research was carried out at Entre Rios do Oeste, Marechal Candido Rondon, Mercedes, Missal, Nova Santa Rosa and Pato Bragado. The isolates were characterized to amylase activity, ƒ¿ and ƒÀ-esterase and aggressiveness. From 61 collected materials, were obtained 19 bacterial isolates, with larger incidence for varieties of human consume than those for industry. Stems from Pato Bragado, Entre Rios do Oeste and Mercedes

  7. Sensibilidade de Xanthomonas axonopodis pv. citri ao cobre e mancozeb Sensibility of Xanthomonas axonopodis pv. citri to copper and mancozeb

    Directory of Open Access Journals (Sweden)

    Luciana Meneguim

    2007-06-01

    Full Text Available O cancro cítrico, causado por Xanthomonas axonopodis pv. citri (Xac é uma das principais doenças na produção de citros em diversas regiões do mundo. A aplicação de produtos químicos com ação bactericida é uma das principais medidas adotadas para o controle dessa doença. O objetivo deste estudo foi determinar a sensibilidade de isolados Xac ao cobre, bem como à mistura de cobre com mancozeb. A maior concentração de cobre em que foi observado crescimento de isolados de Xac foi de 50 µg/mL. Entretanto, 45,5 % dos isolados da bactéria provenientes de pomares que receberam aplicações freqüentes de cobre cresceram na presença de 50 µg/mL de cobre, contra apenas 13,4 % dos isolados oriundos de pomares que não receberam pulverizações regulares do bactericida. A presença de mancozeb em mistura com cúpricos reduziu a sensibilidade ao cobre dos isolados de Xac. Desta forma, o mancozeb não deve ser utilizado em mistura com cobre para o controle do cancro cítrico.Citrus canker, caused by Xanthomonas axonopodis pv. citri (Hasse Vauterin et al. 1995 (Xac, is one of the most important problems for citrus production around the world. Spraying with copper compounds is a major measure for control of the disease. The objective of this study was to determine the sensitivity of Xac strains from the State of Parana, Brazil, to copper as well as to a mixture of copper with mancozeb. The highest copper concentration where Xac grew was 50 µg/mL. However, 45.5 % of the bacterial strains from orchards with regular sprays of copper compounds grew in the presence of 50 µg/mL of copper. In contrast, only 13.4 % of the strains from citrus orchards that never received copper sprays grew in such a copper concentration . Mixing mancozeb with copper increased the tolerance of Xac to copper. Therefore, the recommendation of mancozeb mixed with copper for control of the citrus canker bacterium should be reviewed.

  8. Agressividade de linhagens de Xanthomonas axonopodis pv. aurantifolii Tipo C em lima ácida 'Galego' Aggressiveness of Xanthomonas axonopodis pv. aurantifolii Type C strains in 'Mexican' Lime

    Directory of Open Access Journals (Sweden)

    Letícia A. S. Nociti

    2006-04-01

    Full Text Available O presente trabalho objetivou gerar informações referentes à agressividade de linhagens de Xanthomonas axonopodis pv. aurantifolii Tipo C(Xaa-C, produtoras (PP e não produtoras de pigmento (NP escuro em meio de cultura, comparativamente a X. axonopodis pv. citri Tipo A (Xac . Os tratamentos foram formados por 14 linhagens, sendo sete de Xaa-C PP, cinco Xaa-C NP, e duas linhagens de Xac. As linhagens foram inoculadas através de ferimentos, em folhas de lima ácida 'Galego' (Citrus aurantifolia Swingle, com agulha previamente mergulhada em uma suspensão de células bacterianas (10(7 UFC/mL. Foram realizadas dez repetições para cada tratamento, representadas por uma planta cada. As plantas foram mantidas em casa de vegetação durante todo o experimento. As linhagens diferiram entre si quanto ao período de incubação, diâmetro e populações bacterianas das lesões e, comparativamente, Xaa-C NP mostraram-se mais agressivas do que Xaa-C PP. Algumas linhagens induziram sintomas que diferiram quanto à presença e extensão de anasarca, halo amarelo e saliência do tecido necrosado.The purpose of this research was to provide the information about the aggressiveness of strains of Xanthomonas axonopodis pv. aurantifolii - strains C (Xaa-C, producer (PP or not of dark pigment (NP in culture medium in comparison with X. axonopodis pv. citri - strains A (Xac. A total of 14 strains were inoculated by needle wounds in 'Mexican' Lime (Citrus aurantifolia leaves, with bacterial cell suspension (10(7 CFU/mL: seven were Xaa-C PP, five were not producers and two were Xac strains. Ten replications of one plant each were used in each treatment. The plants were kept in greenhouse during the experiment. The strains differed on incubation period, lesion size and population growth. Xaa NP was more aggressive than PP. Symptoms induced by some strains varied in terms of water-soaked, chlorotic halos and necrosis.

  9. Genomic Insights into the Evolutionary Origin of Xanthomonas axonopodis pv. citri and Its Ecological Relatives

    OpenAIRE

    Midha, Samriti; Patil, Prabhu B.

    2014-01-01

    Xanthomonas axonopodis pv. citri (Xac) is the causal agent of citrus bacterial canker (CBC) and is a serious problem worldwide. Like CBC, several important diseases in other fruits, such as mango, pomegranate, and grape, are also caused by Xanthomonas pathovars that display remarkable specificity toward their hosts. While citrus and mango diseases were documented more than 100 years ago, the pomegranate and grape diseases have been known only since the 1950s and 1970s, respectively. Interesti...

  10. Global Pattern of Gene Expression of Xanthomonas axonopodis pv. glycines Within Soybean Leaves.

    Science.gov (United States)

    Chatnaparat, Tiyakhon; Prathuangwong, Sutruedee; Lindow, Steven E

    2016-06-01

    To better understand the behavior of Xanthomonas axonopodis pv. glycines, the causal agent of bacterial pustule of soybean within its host, its global transcriptome within soybean leaves was compared with that in a minimal medium in vitro, using deep sequencing of mRNA. Of 5,062 genes predicted from a draft genome of X. axonopodis pv. glycines, 534 were up-regulated in the plant, while 289 were down-regulated. Genes encoding YapH, a cell-surface adhesin, as well as several others encoding cell-surface proteins, were down-regulated in soybean. Many genes encoding the type III secretion system and effector proteins, cell wall-degrading enzymes and phosphate transporter proteins were strongly expressed at early stages of infection. Several genes encoding RND multidrug efflux pumps were induced in planta and by isoflavonoids in vitro and were required for full virulence of X. axonopodis pv. glycines, as well as resistance to soybean phytoalexins. Genes encoding consumption of malonate, a compound abundant in soybean, were induced in planta and by malonate in vitro. Disruption of the malonate decarboxylase operon blocked growth in minimal media with malonate as the sole carbon source but did not significantly alter growth in soybean, apparently because genes for sucrose and fructose uptake were also induced in planta. Many genes involved in phosphate metabolism and uptake were induced in planta. While disruption of genes encoding high-affinity phosphate transport did not alter growth in media varying in phosphate concentration, the mutants were severely attenuated for growth in soybean. This global transcriptional profiling has provided insight into both the intercellular environment of this soybean pathogen and traits used by X. axonopodis pv. glycines to promote disease. PMID:27003800

  11. Genetic diversity of Xanthomonas axonopodis pv. citri based on plasmid profile and pulsed field gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Carvalho Flávia Maria de Souza

    2005-01-01

    Full Text Available Xanthomonas axonopodis pv. citri strains that cause disease in citrus were investigated by pulsed field and plasmid profile analysis. For the first method, genomic DNA was digested by the rare-cutting enzymes Xba I and Vsp I. The strains evaluated were collected in seven different States of Brazil and in Argentina, Bolivia, Paraguay and Uruguay. Genetic variability was found among strains of X. axonopodis pv. citri from different geographical areas Argentina, Bolivia and Uruguay, with similarities varying from 0.62 to 0.83. However, the strains collected in Brazil, despite being from different States, have shown a genetic similarity ranging from 0.83 to 1.00. Cluster analysis showed a relationship between genomic similarity and geographical origin of the strains. Plasmids were observed in all strains, with a total of five different plasmids, with sizes between 57.7 and 83.0 kilobases. The 72.6 kb plasmid was the most frequent, present in 15 out of 22 strains, while the 68.1 kb plasmid was observed in two strains only. Although the plasmid diversity detected in the present study was not very great, the X. axonopodis pv. citri strains evaluated showed a considerable degree of diversity with regard to this extrachromosomal genetic element.

  12. Antibacterial activity of plant extracts against Xanthomonas axonopodis Pv. Punicae causing bacterial blight of Pomegranate (Punica granatum L.

    Directory of Open Access Journals (Sweden)

    Alane S K

    2016-01-01

    Full Text Available Pomegranate (Punica granatum L. is the important fruit crop cultivated throughout the world. It is famous for its refreshing fruits. The crop is affected by ‘bacterial blight’ caused by Xanthomonas axonopodis pv. punicae, which is responsible for the failure of crop. It results in the dropping of leaves as well as fruits. It is very hard to manage the disease with chemicals as well as antibiotics and farmers suffer from heavy economic losses. In the present study, aqueous, ethyl alcohol and acetone extracts of ten medicinally useful plants were used against Xanthomonas axonopodis pv. punicae in vitro. The plant extracts showed antibacterial activity and caused inhibition of growth of Xanthomonas axonopodis pv. Punicae. Among them, Mentha spicata, Murraya Koeninngi, Allium sativum and Tridax procumbens caused maximum inhibition of the test bacterium.

  13. Characterization of Bacteriophages Cp1 and Cp2, the Strain-Typing Agents for Xanthomonas axonopodis pv. citri

    OpenAIRE

    Ahmad, Abdelmonim Ali; Ogawa, Megumi; Kawasaki, Takeru; Fujie, Makoto; Yamada, Takashi

    2014-01-01

    The strains of Xanthomonas axonopodis pv. citri, the causative agent of citrus canker, are historically classified based on bacteriophage (phage) sensitivity. Nearly all X. axonopodis pv. citri strains isolated from different regions in Japan are lysed by either phage Cp1 or Cp2; Cp1-sensitive (Cp1s) strains have been observed to be resistant to Cp2 (Cp2r) and vice versa. In this study, genomic and molecular characterization was performed for the typing agents Cp1 and Cp2. Morphologically, Cp...

  14. CHARACTERIZATION OF XANTHOMONAS AXONOPODIS PV. PUNICAE ISOLATES FROM WESTERN MAHARASHTRA AND THEIR SENSITIVITY TO CHEMICAL TREATMENTS

    Directory of Open Access Journals (Sweden)

    K. S. RAGHUWANSHI

    2013-01-01

    Full Text Available Bacterial blight of pomegranate caused by Xanthomonas axonopodis pv. punicae is a major biotic constraint inpeninsular India. Field survey was undertaken in the major pomegranate growing regions of Western Maharashtra,which revealed the high prevalence of bacterial blight incidence in Solapur, Sangli and Nashik districts. Fourdifferent isolates of this pathogen were obtained from the highly infected plant materials collected during the fieldsurvey. X. axonopodis pv. punicae was detected from infected plant material and its identity was confirmed bymorphological, physiological, hypersensitive and pathogenicity tests. Nashik isolate was most virulent. On InterSimple Sequence Repeat (ISSR analysis they formed separate clusters with Akkalkot-Solapur isolate being mostdivergent, while Deola-Nashik and Sangamner-Ahmednagar isolates were most similar. Six chemical treatmentsshowed complete control under in vitro conditions while rest varied in their response to isolates. Completecontrol in all four isolates was observed with Bordeaux mixture (1%; captan (0.25% + Copper oxychloride(0.3%, captan (0.25% + copper hydroxide (0.3%, bromopol (500 ppm + copper oxychloride (0.3%,streptocycline (250 ppm + copper hydroxide (0.3%, streptocycline (500 ppm + copper hydroxide (0.3%during in vitro study

  15. Produção e sensibilidade de isolados brasileiros de Xanthomonas axonopodis pv. citri à bacteriocinas

    Directory of Open Access Journals (Sweden)

    Marcel Bonini

    2012-09-01

    Full Text Available Este trabalho teve por objetivo avaliar a produção e a sensibilidade de 48 isolados brasileiros de X. axonopodis pv. citri (Xac à bacteriocinas. Pelos resultados obtidos, nenhum isolado de Xac foi sensível às bacteriocinas produzidas pelos isolados bacterianos avaliados.

  16. Identification of differentially expressed genes of Xanthomonas axonopodis pv. citri by representational difference analysis of cDNA

    Directory of Open Access Journals (Sweden)

    Angela Mehta

    2005-03-01

    Full Text Available Xanthomonas axonopodis pv. citri is a phytopathogenic bacterium responsible for citrus canker, a serious disease which causes severe losses in citriculture around the world. In this study we report the differential expression of X. axonopodis pv. citri in response to specific treatments by using Representational Difference Analysis of cDNA (cDNA RDA. cDNAs from X. axonopodis pv. citri cultured in the presence of leaf extract of the host plant (Citrus sinensis, in vivo, as well as in the complex medium were hybridized against cDNA of the bacterium grown in the minimal medium. Sequencing of the difference products obtained after the second and third hybridizations revealed a total of 37 distinct genes identified by homology searches in the genome of X. axonopodis pv. citri. These genes were distributed in different functional categories, including genes that encode hypothetical proteins, genes involved in metabolism, cellular processes and pathogenicity, and mobile genetic elements. Most of these genes are likely related to growth and/or acquisition of nutrients in specific treatments whereas others might be important for the bacterium pathogenicity.

  17. A LOV protein modulates the physiological attributes of Xanthomonas axonopodis pv. citri relevant for host plant colonization.

    Directory of Open Access Journals (Sweden)

    Ivana Kraiselburd

    Full Text Available Recent studies have demonstrated that an appropriate light environment is required for the establishment of efficient vegetal resistance responses in several plant-pathogen interactions. The photoreceptors implicated in such responses are mainly those belonging to the phytochrome family. Data obtained from bacterial genome sequences revealed the presence of photosensory proteins of the BLUF (Blue Light sensing Using FAD, LOV (Light, Oxygen, Voltage and phytochrome families with no known functions. Xanthomonas axonopodis pv. citri is a Gram-negative bacterium responsible for citrus canker. The in silico analysis of the X. axonopodis pv. citri genome sequence revealed the presence of a gene encoding a putative LOV photoreceptor, in addition to two genes encoding BLUF proteins. This suggests that blue light sensing could play a role in X. axonopodis pv. citri physiology. We obtained the recombinant Xac-LOV protein by expression in Escherichia coli and performed a spectroscopic analysis of the purified protein, which demonstrated that it has a canonical LOV photochemistry. We also constructed a mutant strain of X. axonopodis pv. citri lacking the LOV protein and found that the loss of this protein altered bacterial motility, exopolysaccharide production and biofilm formation. Moreover, we observed that the adhesion of the mutant strain to abiotic and biotic surfaces was significantly diminished compared to the wild-type. Finally, inoculation of orange (Citrus sinensis leaves with the mutant strain of X. axonopodis pv. citri resulted in marked differences in the development of symptoms in plant tissues relative to the wild-type, suggesting a role for the Xac-LOV protein in the pathogenic process. Altogether, these results suggest the novel involvement of a photosensory system in the regulation of physiological attributes of a phytopathogenic bacterium. A functional blue light receptor in Xanthomonas spp. has been described for the first time, showing

  18. Multiplexed lateral flow microarray assay for detection of citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis pv citri

    Science.gov (United States)

    Cary; R. Bruce; Stubben, Christopher J.

    2011-03-22

    The invention provides highly sensitive and specific assays for the major citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis, including a field deployable multiplexed assay capable of rapidly assaying for both pathogens simultaneously. The assays are directed at particular gene targets derived from pathogenic strains that specifically cause the major citrus diseases of citrus variegated chlorosis (Xylella fastidiosa 9a5c) and citrus canker (Xanthomonas axonopodis pv citri). The citrus pathogen assays of the invention offer femtomole sensitivity, excellent linear dynamic range, and rapid and specific detection.

  19. Comparative Genomic Analysis of Xanthomonas axonopodis pv. citrumelo F1, Which Causes Citrus Bacterial Spot Disease, and Related Strains Provides Insights into Virulence and Host Specificity ▿ #

    OpenAIRE

    Jalan, Neha; Aritua, Valente; Kumar, Dibyendu; Yu, Fahong; Jones, Jeffrey B; Graham, James H; Setubal, João C; Wang, Nian

    2011-01-01

    Xanthomonas axonopodis pv. citrumelo is a citrus pathogen causing citrus bacterial spot disease that is geographically restricted within the state of Florida. Illumina, 454 sequencing, and optical mapping were used to obtain a complete genome sequence of X. axonopodis pv. citrumelo strain F1, 4.9 Mb in size. The strain lacks plasmids, in contrast to other citrus Xanthomonas pathogens. Phylogenetic analysis revealed that this pathogen is very close to the tomato bacterial spot pathogen X. camp...

  20. Transformation of Xanthomonas axonopodis pv. citri by electroporation Transformação de Xanthomonas axonopodis pv. citri através de eletroporação

    Directory of Open Access Journals (Sweden)

    Alexandre M. do Amaral

    2005-06-01

    Full Text Available This study describes the use of electroporation for transforming Xanthomonas axonopodis pv. citri (Xac, the causal agent of citrus (Citrus spp. canker. It also evaluates the methodology used for this species under different electrical parameters. The bacterium used in the study (Xac 306 was the same strain used for recent complete sequencing of the organism. The use of a plasmid (pUFR047, gentamycin r is reported here to be able to replicate in cells of Xac. Following the preparation and resuspension of competent cells of Xac at a density of ~4 x 10(10 cfu/ml, in 10% glycerol, and the addition of the replicative plasmid, an electrical pulse was applied to each treatment. Selection of transformants showed a high efficiency of transformation (1.1 x 10(6 transformants/mug DNA, which indicates an effective, and inverse, combination between electrical resistance (50 W and capacitance (50 µF for this species, with an electrical field strength of 12.5 kV.cm-1 and 2.7-ms pulse duration. Besides the description of a method for electroporation of Xac 306, this study provides additional information for the use of the technique on studies for production of mutants of this species.É descrito o uso da eletroporação para a transformação de Xanthomonas axonopodis pv. citri (Xac, a agente causal do cancro cítrico, e a avaliação da metodologia para esta espécie sob diferentes parâmetros elétricos. A bactéria utilizada neste estudo (Xac 306 foi a mesma isolado usado recentemente no seqüenciamento completo do organismo. Aqui, é documentado o uso do plasmídeo pUFR047 (gentamicina r capaz de replicar em células de Xac. Após a preparação e re-suspensão das células competentes de Xac na densidade de ~4 x 10(10 ufc/ml, em 10% glycerol, e a adição do plasmídeo replicativo, um pulso elétrico foi aplicado a cada tratamento. A seleção dos transformantes mostrou uma alta eficiência de transformação (1,1 x 10(6 transformantes/mig DNA, o que

  1. Crystal Structure of the FAD-Containing Ferredoxin-NADP+ Reductase from the Plant Pathogen Xanthomonas axonopodis pv. citri

    Directory of Open Access Journals (Sweden)

    María Laura Tondo

    2013-01-01

    Full Text Available We have solved the structure of ferredoxin-NADP(H reductase, FPR, from the plant pathogen Xanthomonas axonopodis pv. citri, responsible for citrus canker, at a resolution of 1.5 Å. This structure reveals differences in the mobility of specific loops when compared to other FPRs, probably unrelated to the hydride transfer process, which contributes to explaining the structural and functional divergence between the subclass I FPRs. Interactions of the C-terminus of the enzyme with the phosphoadenosine of the cofactor FAD limit its mobility, thus affecting the entrance of nicotinamide into the active site. This structure opens the possibility of rationally designing drugs against the X. axonopodis pv. citri phytopathogen.

  2. Mutation in the xpsD gene of Xanthomonas axonopodis pv. citri affects cellulose degradation and virulence

    Directory of Open Access Journals (Sweden)

    Juliana Cristina Baptista

    2010-01-01

    Full Text Available The Gram-negative bacterium Xanthomonas axonopodis pv. citri, the causal agent of citrus canker, is a major threat to the citrus industry worldwide. Although this is a leaf spot pathogen, it bears genes highly related to degradation of plant cell walls, which are typically found in plant pathogens that cause symptoms of tissue maceration. Little is known on Xac capacity to cause disease and hydrolyze cellulose. We investigated the contribution of various open reading frames on degradation of a cellulose compound by means of a global mutational assay to selectively screen for a defect in carboxymethyl cellulase (CMCase secretion in X. axonopodis pv. citri. Screening on CMC agar revealed one mutant clone defective in extracellular glycanase activity, out of nearly 3,000 clones. The insertion was located in the xpsD gene, a component of the type II secretion system (T2SS showing an influence in the ability of Xac to colonize tissues and hydrolyze cellulose. In summary, these data show for the first time, that X. axonopodis pv. citri is capable of hydrolyzing cellulose in a T2SS-dependent process. Furthermore, it was demonstrated that the ability to degrade cellulose contributes to the infection process as a whole.

  3. Biological, serological and molecular techniques to xanthomonas axonopodis pv. Ci tri Asymptomatic detection

    International Nuclear Information System (INIS)

    Xanthomonas axonopodis pv. ci tri (X ac) produces citrus canker disease in all citrus commercial species. The bacteria can be disseminated through vegetative propagation material in asymptomatic form. To optimize bacteria detection techniques applicable to asymptomatic citrus plant tissue routine analysis, ELISA, Immunofluorescence, Pcr, qRTPCR and host plant inoculation (bioassay) diagnostic techniques were compared. Tests were made from decimal dilutions between 108 uf6.ml-1 and 102 ufc.mL-1 using a pure culture of 49b strain.The detection level obtained was 1.8 x 102 ufc.mL-1 using Inmunofluorescence; 1.8x104 ufc.mL-1 with indirect ELISA, 1.8 x 103 ufc.mL-1 by means of PCR; 10 ufc.mL-1 through of qRTPCR and 230 ufc.mL-1 in sour orange inoculated plants. The experiment was repeated at least three times for each technique. Considering this result, and taking into account that sensitivity, practicity and cost, are important when a great number of plants need to be tested, the PCR and inoculation in host plants were those that met the best characteristics to be evaluated in asymptomatic plant material

  4. Genome sequencing reveals a new lineage associated with lablab bean and genetic exchange between Xanthomonas axonopodis pv. phaseoli and Xanthomonas fuscans subsp. fuscans

    Directory of Open Access Journals (Sweden)

    Valente eAritua

    2015-10-01

    Full Text Available Common bacterial blight is a devastating seed-borne disease of common beans that also occurs on other legume species including lablab and Lima beans. We sequenced and analysed the genomes of 26 isolates of Xanthomonas axonopodis pv. phaseoli and X. fuscans subsp. fuscans, the causative agents of this disease, collected over four decades and six continents. This revealed considerable genetic variation within both taxa, encompassing both single-nucleotide variants and differences in gene content, that could be exploited for tracking pathogen spread. The bacterial isolate from Lima bean fell within the previously described Genetic Lineage 1, along with the pathovar type isolate (NCPPB 3035. The isolates from lablab represent a new, previously unknown genetic lineage closely related to strains of X. axonopodis pv. glycines. Finally, we identified more than 100 genes that appear to have been recently acquired by Xanthomonas axonopodis pv. phaseoli from X. fuscans subsp. fuscans.

  5. COMPARING INOCULATION METHODS TO EVALUATE THE GROWTH OF Xanthomonas axonopodis pv. manihotis ON CASSAVA PLANTS

    Directory of Open Access Journals (Sweden)

    Alejandra Muñoz Bodnar

    2014-11-01

    Full Text Available Xanthomonas axonopodis pv. manihotis (Xam is the causal agent of cassava bacterial blight (CBB, a major disease for cassava crops in South America and Africa. Until now the development of the disease is measured via AUDPC (Area Under Disease Progress Curve but no reliable quantitative methods are available probably due to high variability of bacterial growth in planta. To establish an accurate method for bacterial quantification during the course of Xam infection within the host tissues, we analyzed bacterial populations upon stem and leaf-puncturing as well as leaf-clipping of cassava varieties MCOL1522 and SG107-35 challenged with the virulent Xam strain CIO151. Here, we show that the movement of bacteria along the tissues and especially in leaves is stochastic. Moreover, we were able to demonstrate differential growth of virulent Xam strain CIO151 upon stem-puncturing and quantification of bacteria 6 cm. away from the inoculation point of two varieties displaying contrasting levels of susceptibility.RESUMEN Normal 0 21 false false false ES-CO X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Xanthomonas axonopodis pv. manihotis (Xam es el agente causal del tizón bacteriano de la yuca, una de las principales enfermedades de los cultivos de yuca en América del Sur y África. Hasta ahora, el desarrollo de la

  6. Structural-functional characterization and physiological significance of ferredoxin-NADP reductase from Xanthomonas axonopodis pv. citri.

    Directory of Open Access Journals (Sweden)

    María Laura Tondo

    Full Text Available Xanthomonas axonopodis pv. citri is a phytopathogen bacterium that causes severe citrus canker disease. Similar to other phytopathogens, after infection by this bacterium, plants trigger a defense mechanism that produces reactive oxygen species. Ferredoxin-NADP(+ reductases (FNRs are redox flavoenzymes that participate in several metabolic functions, including the response to reactive oxygen species. Xanthomonas axonopodis pv. citri has a gene (fpr that encodes for a FNR (Xac-FNR that belongs to the subclass I bacterial FNRs. The aim of this work was to search for the physiological role of this enzyme and to characterize its structural and functional properties. The functionality of Xac-FNR was tested by cross-complementation of a FNR knockout Escherichia coli strain, which exhibit high susceptibility to agents that produce an abnormal accumulation of (•O(2(-. Xac-FNR was able to substitute for the FNR in E. coli in its antioxidant role. The expression of fpr in X. axonopodis pv. citri was assessed using semiquantitative RT-PCR and Western blot analysis. A 2.2-fold induction was observed in the presence of the superoxide-generating agents methyl viologen and 2,3-dimethoxy-1,4-naphthoquinone. Structural and functional studies showed that Xac-FNR displayed different functional features from other subclass I bacterial FNRs. Our analyses suggest that these differences may be due to the unusual carboxy-terminal region. We propose a further classification of subclass I bacterial FNRs, which is useful to determine the nature of their ferredoxin redox partners. Using sequence analysis, we identified a ferredoxin (XAC1762 as a potential substrate of Xac-FNR. The purified ferredoxin protein displayed the typical broad UV-visible spectrum of [4Fe-4S] clusters and was able to function as substrate of Xac-FNR in the cytochrome c reductase activity. Our results suggest that Xac-FNR is involved in the oxidative stress response of Xanthomonas axonopodis pv

  7. Crystallization, data collection and phasing of the molybdate-binding protein of the phytopathogen Xanthomonas axonopodis pv. citri

    Energy Technology Data Exchange (ETDEWEB)

    Santacruz, C. P.; Balan, A.; Ferreira, L. C. S. [Departamento de Microbiologia, Instituto de Ciências Biomédicas II, Universidade de São Paulo, São Paulo, SP (Brazil); Barbosa, J. A. R. G., E-mail: joao@lnls.br [Centro de Biologia Molecular e Estrutural (CeBiMe), Laboratório Nacional de Luz Síncrotron (LNLS), CP 6192, Campinas, SP 13084-971 (Brazil); Departamento de Microbiologia, Instituto de Ciências Biomédicas II, Universidade de São Paulo, São Paulo, SP (Brazil)

    2006-03-01

    The molybdate-binding protein (ModA) from X. axonopodis pv. citri was crystallized with sodium molybdate in the presence of PEG or sulfate. The crystal diffracted to a maximum resolution of 1.7 Å and belongs to the orthorhombic space group C222{sub 1,} with unit-cell parameters a = 68.15, b = 172.14, c = 112.04 Å. Xanthomonas axonopodis pv. citri ModA protein is the ABC periplasmic binding component responsible for the capture of molybdate. The protein was crystallized with sodium molybdate using the hanging-drop vapour-diffusion method in the presence of PEG or sulfate. X-ray diffraction data were collected to a maximum resolution of 1.7 Å using synchrotron radiation. The crystal belongs to the orthorhombic space group C222{sub 1}, with unit-cell parameters a = 68.15, b = 172.14, c = 112.04 Å. The crystal structure was solved by molecular-replacement methods and structure refinement is in progress.

  8. Differential expression of pathogenicity- and virulence-related genes of Xanthomonas axonopodis pv. citri under copper stress

    Directory of Open Access Journals (Sweden)

    Ana Carolina Basílio Palmieri

    2010-01-01

    Full Text Available In this study, we used real-time quantitative PCR (RT-qPCR to evaluate the expression of 32 genes of Xanthomonas axonopodis pv. citri related to pathogenicity and virulence that are also involved in copper detoxification. Nearly all of the genes were up-regulated, including copA and copB. Two genes homologous to members of the type II secretion system (xcsH and xcsC and two involved in the degradation of plant cell wall components (pglA and pel were the most expressed in response to an elevated copper concentration. The type II secretion system (xcs operon and a few homologues of proteins putatively secreted by this system showed enhanced expression when the bacteria were exposed to a high concentration of copper sulfate. The enhanced expression of the genes of secretion II system during copper stress suggests that this pathway may have an important role in the adaptative response of X. axonopodis pv. citri to toxic compounds. These findings highlight the potential role of these genes in attenuating the toxicity of certain metals and could represent an important means of bacterial resistance against chemicals used to control diseases.

  9. Microarray analysis of the semi-compatible pathogenic response and recovery of leafy spurge inoculated with the Cassava bacterial blight pathogen Xanthomonas axonopodis pv. manihotis

    Science.gov (United States)

    Infection by Xanthomonas axonopodis pv. manihotis (Xam)of the model perennial range land weed leafy spurge was tested to see if Xam might serve a potential biological control agent for this invasive weed. Although leafy spurge was susceptible to Xam infection, it recovered with 21 days after inocula...

  10. Genomic survey of pathogenicity determinants and VNTR markers in the cassava bacterial pathogen Xanthomonas axonopodis pv. Manihotis strain CIO151.

    Directory of Open Access Journals (Sweden)

    Mario L Arrieta-Ortiz

    Full Text Available Xanthomonas axonopodis pv. manihotis (Xam is the causal agent of bacterial blight of cassava, which is among the main components of human diet in Africa and South America. Current information about the molecular pathogenicity factors involved in the infection process of this organism is limited. Previous studies in other bacteria in this genus suggest that advanced draft genome sequences are valuable resources for molecular studies on their interaction with plants and could provide valuable tools for diagnostics and detection. Here we have generated the first manually annotated high-quality draft genome sequence of Xam strain CIO151. Its genomic structure is similar to that of other xanthomonads, especially Xanthomonas euvesicatoria and Xanthomonas citri pv. citri species. Several putative pathogenicity factors were identified, including type III effectors, cell wall-degrading enzymes and clusters encoding protein secretion systems. Specific characteristics in this genome include changes in the xanthomonadin cluster that could explain the lack of typical yellow color in all strains of this pathovar and the presence of 50 regions in the genome with atypical nucleotide composition. The genome sequence was used to predict and evaluate 22 variable number of tandem repeat (VNTR loci that were subsequently demonstrated as polymorphic in representative Xam strains. Our results demonstrate that Xanthomonas axonopodis pv. manihotis strain CIO151 possesses ten clusters of pathogenicity factors conserved within the genus Xanthomonas. We report 126 genes that are potentially unique to Xam, as well as potential horizontal transfer events in the history of the genome. The relation of these regions with virulence and pathogenicity could explain several aspects of the biology of this pathogen, including its ability to colonize both vascular and non-vascular tissues of cassava plants. A set of 16 robust, polymorphic VNTR loci will be useful to develop a multi

  11. Detecção de Xanthomonas axonopodis pv. phaseoli em sementes de feijão em meio de cultura semi seletivo Detection of Xanthomonas axonopodis pv. phaseoli in seeds of common bean on semi-selective medium

    OpenAIRE

    Nilvanira D. Tebaldi; Ricardo M. de Souza; José C. Machado

    2007-01-01

    Para a detecção de Xanthomonas axonopodis pv. phaseoli (Xap) em extratos de sementes inteiras e moídas de feijão, naturalmente contaminadas e sadias foram utilizados os meio de cultura semi-seletivos XCP1 e MT e o não seletivo 523 de Kado & Hesket. Os extratos de sementes foram também inoculados em folhas primárias de feijoeiro. O meio de cultura semi-seletivo XCP1 foi o mais eficiente na quantificação e detecção de Xap em extratos de sementes inteiras de feijão. Os extratos de sementes conta...

  12. Detecção de Xanthomonas axonopodis pv. phaseoli em sementes de feijoeiro provenientes do estado do Paraná, Brasil Detection of Xanthomonas axonopodis pv. phaseoli in common bean seeds from the state of Paraná (Brazil

    Directory of Open Access Journals (Sweden)

    João Pereira Torres

    2009-06-01

    Full Text Available O crestamento bacteriano comum do feijoeiro causado por sobrevivência e disseminação da Xap, a semente representa o mais Xanthomonas axonopodis pv. phaseoli (Xap é a principal doença eficiente. A qualidade sanitária de 34 amostras de sementes de feijoeiro do feijoeiro comum no Brasil. O patógeno encontra-se disseminado produzidas no estado do Paraná, nas safras 1998/99 e 1999, foram em todas as regiões produtoras do país, porém com maior importância avaliadas quanto à presença de Xap em macerados de sementes nos estados do Paraná, Rio de Janeiro, São Paulo e na região do Brasil plaqueados em meio semi-seletivo. Cinqüenta por cento dos lotes de Central, sobretudo na safra das águas. Dentre os vários meios de sementes foram portadores de Xap com incidência de 0,1% a 1,7%.The common bacterial blight of bean, caused by Xanthomonas effective means of survival and dissemination of the Xap. The health axonopodis pv. phaseoli (Xap, is a major disease of common beans quality of 34 samples of seeds lots of common beans produced in the in Brazil. Even though this pathogen is disseminated in all production state of Paraná during 1998/99 and 1999 were evaluated to the presence regions of the country, it has caused major damages in the states of of Xap in seed macerates plated on a semi-selective culture medium. Paraná, Rio de Janeiro and São Paulo and in Central Region of Brazil, Fifty percent of the seed lots were carrying out by Xap with an particularly during the rainy season. Infected bean seeds are most incidence range of 0.1% to 1.7%.

  13. Crystallization, data collection and data processing of maltose-binding protein (MalE) from the phytopathogen Xanthomonas axonopodis pv. citri

    International Nuclear Information System (INIS)

    The Xanthomonas axonopodis pv. citri maltose-binding protein MalE has been crystallized at 293 K using the hanging-drop vapour-diffusion method. Maltose-binding protein is the periplasmic component of the ABC transporter responsible for the uptake of maltose/maltodextrins. The Xanthomonas axonopodis pv. citri maltose-binding protein MalE has been crystallized at 293 K using the hanging-drop vapour-diffusion method. The crystal belonged to the primitive hexagonal space group P6122, with unit-cell parameters a = 123.59, b = 123.59, c = 304.20 Å, and contained two molecules in the asymetric unit. It diffracted to 2.24 Å resolution

  14. The filamentous phage XacF1 causes loss of virulence in Xanthomonas axonopodis pv. citri, the causative agent of citrus canker disease

    OpenAIRE

    Ahmad, Abdelmonim Ali; Askora, Ahmed; Kawasaki, Takeru; Fujie, Makoto; Yamada, Takashi

    2014-01-01

    In this study, filamentous phage XacF1, which can infect Xanthomonas axonopodis pv. citri (Xac) strains, was isolated and characterized. Electron microscopy showed that XacF1 is a member of the family Inoviridae and is about 600 nm long. The genome of XacF1 is 7325 nucleotides in size, containing 13 predicted open reading frames (ORFs), some of which showed significant homology to Ff-like phage proteins such as ORF1 (pII), ORF2 (pV), ORF6 (pIII), and ORF8 (pVI). XacF1 showed a relatively wide...

  15. Spectroscopic characterization of the exopolysaccharide of Xanthomonas axonopodis pv. citri in Cu{sup 2+} resistance mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Osiro, Denise [Universidade de Sao Paulo (IQSC/USP), Sao Carlos, SP (Brazil). Inst. de Quimica; Franco, Roberto W. Assis; Colnago, Luiz Alberto, E-mail: colnago@cnpdia.embrapa.b [EMBRAPA Instrumentacao Agropecuaria, Sao Carlos, SP (Brazil)

    2011-07-01

    We analyzed the role of exopolysaccharide in the Xanthomonas axonopodis pv. citri (Xac) Cu{sup 2+} resistance mechanism by Fourier transform infrared (FTIR), electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR) spectroscopies. The FTIR data show that cells cultivated in the presence of 0.2 mmol L{sup -1} of CuSO{sub 4} produce larger amounts of pyruvated exopolissacharide (EPS) than the ones cultivated in its absence. The EPR data indicate that the amount of Cu{sup 2+} decreases with cultivation time. The {sup 13}C-CPMAS NMR data also show the complexation of Cu{sup 2+} ions to the EPS. The results demonstrate that EPS plays an important role in Xac Cu{sup 2+} protection. Both capsular and slime EPS act as an initial protection mechanism, binding free Cu{sup 2+} ions, reducing their diffusion and their active transport to the cytoplasm. Cu{sup 2+} also induces the production of a highly pyruvated negative EPS, increasing its capture and binding capacity. (author)

  16. LA PROTEÍNA PTHB DE Xanthomonas axonopodis pv. Manihotis ES AUTOACTIVA EN ENSAYOS DE DOBLE HÍBRIDO The PthB Protein from Xanthomonas axonopodis pv. Manihotis is an Autoactive in Yeast Two-Hybrid Assays

    Directory of Open Access Journals (Sweden)

    JULIANA GIL

    Full Text Available La bacteriosis vascular de yuca producida por la bacteria Xanthomonas axonopodis pv. manihotis (Xam es una enfermedad limitante para la producción de yuca. Dentro de los primeros factores de patogenicidad identificados en esta bacteria se encuentra el gen PthB. La proteína PthB pertenece a la familia de efectores PthA/AvrBs3, que se caracterizan por presentar dominios NLS (Nuclear Localization Signal y un dominio AAD (Acidic Activation Domain, lo cual sugiere que estas proteínas actúan como factores de transcripción. La identificación de las proteínas de yuca que interactúan con PthB permitiría dar luces sobre la función de esta proteína en la patogenicidad de esta bacteria. En este trabajo se clonó PthB en una fusión traduccional con el BD (Binding Domain del factor de transcripción GAL4. Después de transformar este constructo en una cepa de levadura, se observó autoactivación de los genes reporteros, incluso a concentraciones altas de 3-AT. La eliminación del primer, segundo o de los dos NLS y del AAD no eliminaron la capacidad de autoactivación de los genes reporteros mediada por PthB. Estos resultados indican la imposibilidad de su utilización en un tamizaje de una librería de ADNc de yuca para identificar las proteínas que interactúan con PthB.Cassava bacterial blight disease is caused by the gram-negative bacteria Xanthomonas axonopodis pv. manihotis (Xam, and constitutes one of the most important constraints for cassava production. One of the first determinants of pathogenicity identified in this bacterium is the PthB gene. The PthB protein belongs to the PthA/AvrBs3 family, characterized by the presence of Nuclear Localization Signal (NLS and Acidic Activation (AAD domains, suggesting that these proteins are transcription factors. The identification of cassava proteins interacting with PthB could give insights about the function of this protein in the pathogenicity of this bacterium. In this work we cloned PthB in

  17. Expression, crystallization and preliminary crystallographic analysis of SufE (XAC2355) from Xanthomonas axonopodis pv. citri

    International Nuclear Information System (INIS)

    Cloning, expression, purification, crystallization and data collection are reported for a member of the SufE family of proteins involved in the biosynthesis of Fe–S clusters in prokaryotes. Diffraction data were collected to 1.9 Å resolution and an interpretable electron-density map has been obtained by molecular replacement. Xanthomonas axonopodis pv. citri (Xac) SufE (XAC2355) is a member of a family of bacterial proteins that are conserved in several pathogens and phytopathogens. The Escherichia coli suf operon is involved in iron–sulfur cluster biosynthesis under iron-limitation and stress conditions. It has recently been demonstrated that SufE and SufS form a novel two-component cysteine desulfarase in which SufS catalyses the conversion of l-cysteine to l-alanine, forming a protein-bound persulfide intermediate. The S atom is then transferred to SufE, from which it is subsequently transferred to target molecules or reduced to sulfide in solution. Here, the cloning, expression, crystallization and phase determination of Xac SufE crystals are described. Recombinant SufE was crystallized in space group P212121 and diffracted to 1.9 Å resolution at a synchrotron source. The unit-cell parameters are a = 45.837, b = 58.507, c = 98.951 Å, α = β = γ = 90°. The calculated Matthews coefficient indicated the presence of two molecules in the asymmetric unit. Phasing was performed by molecular-replacement using E. coli SufE as a model (PDB code 1mzg) and an interpretable map was obtained

  18. Bioinformatic identification of cassava miRNAs differentially expressed in response to infection by Xanthomonas axonopodis pv. manihotis

    Directory of Open Access Journals (Sweden)

    Pérez-Quintero Álvaro L

    2012-02-01

    Full Text Available Abstract Background microRNAs (miRNAs are short RNA molecules that control gene expression by silencing complementary mRNA. They play a crucial role in stress response in plants, including biotic stress. Some miRNAs are known to respond to bacterial infection in Arabidopsis thaliana but it is currently unknown whether these responses are conserved in other plants and whether novel species-specific miRNAs could have a role in defense. Results This work addresses the role of miRNAs in the Manihot esculenta (cassava-Xanthomonas axonopodis pv. manihotis (Xam interaction. Next-generation sequencing was used for analyzing small RNA libraries from cassava tissue infected and non-infected with Xam. A full repertoire of cassava miRNAs was characterized, which included 56 conserved families and 12 novel cassava-specific families. Endogenous targets were predicted in the cassava genome for many miRNA families. Some miRNA families' expression was increased in response to bacterial infection, including miRNAs known to mediate defense by targeting auxin-responding factors as well as some cassava-specific miRNAs. Some bacteria-repressed miRNAs included families involved in copper regulation as well as families targeting disease resistance genes. Putative transcription factor binding sites (TFBS were identified in the MIRNA genes promoter region and compared to promoter regions in miRNA target genes and protein coding genes, revealing differences between MIRNA gene transcriptional regulation and other genes. Conclusions Taken together these results suggest that miRNAs in cassava play a role in defense against Xam, and that the mechanism is similar to what's known in Arabidopsis and involves some of the same families.

  19. La proteína PthB de Xanthomonas axonopodis pv. manihotis es autoactiva en ensayos de doble hibrido

    Directory of Open Access Journals (Sweden)

    Gil Juliana

    2011-04-01

    Full Text Available La bacteriosis vascular de yuca producida por la bacteria Xanthomonas axonopodis pv. manihotis (Xam es uno de los factores limitantes para la producción de yuca. Dentro de los primeros factores de patogenicidad identificados en esta bacteria se encuentra el gen pthB. La proteína PthB pertenece a la familia de efectores PthA/AvrBs3, que se caracterizan por presentar dominios NLS (Nuclear Localization Signal y un dominio AAD (Acidic Activation Domain, lo cual sugiere que estas proteínas actúan como factores de transcripción. La identificación de las proteínas de yuca que interactúan con PthB permitiría dar luces sobre la función de esta proteína en la patogenicidad de esta bacteria. En este trabajo se clonó pthB en una fusión traduccional con el BD (Binding Domain del factor de transcripción GAL4. Después de transformar este constructo en una cepa de levadura, se observó autoactivación de los genes reporteros, incluso a concentraciones altas de 3-AT. La eliminación del primer, segundo o de los dos NLS y del AAD no eliminaron la capacidad de autoactivación de los genes reporteros mediada por PthB. Estos resultados indican la imposibilidad de su utilización en un tamizaje de una librería de ADNc de yuca para identificar las proteínas que interactúan con PthB.

  20. Comparison of gene activation by two TAL effectors from Xanthomonas axonopodis pv. manihotis reveals candidate host susceptibility genes in cassava.

    Science.gov (United States)

    Cohn, Megan; Morbitzer, Robert; Lahaye, Thomas; Staskawicz, Brian J

    2016-08-01

    Xanthomonas axonopodis pv. manihotis (Xam) employs transcription activator-like (TAL) effectors to promote bacterial growth and symptom formation during infection of cassava. TAL effectors are secreted via the bacterial type III secretion system into plant cells, where they are directed to the nucleus, bind DNA in plant promoters and activate the expression of downstream genes. The DNA-binding activity of TAL effectors is carried out by a central domain which contains a series of repeat variable diresidues (RVDs) that dictate the sequence of bound nucleotides. TAL14Xam668 promotes virulence in Xam strain Xam668 and has been shown to activate multiple cassava genes. In this study, we used RNA sequencing to identify the full target repertoire of TAL14Xam668 in cassava, which includes over 50 genes. A subset of highly up-regulated genes was tested for activation by TAL14CIO151 from Xam strain CIO151. Although TAL14CIO151 and TAL14Xam668 differ by only a single RVD, they display differential activation of gene targets. TAL14CIO151 complements the TAL14Xam668 mutant defect, implying that shared target genes are important for TAL14Xam668 -mediated disease susceptibility. Complementation with closely related TAL effectors is a novel approach to the narrowing down of biologically relevant susceptibility genes of TAL effectors with multiple targets. This study provides an example of how TAL effector target activation by two strains within a single species of Xanthomonas can be dramatically affected by a small change in RVD-nucleotide affinity at a single site, and reflects the parameters of RVD-nucleotide interaction determined using designer TAL effectors in transient systems. PMID:26575863

  1. Genome-wide mutagenesis of Xanthomonas axonopodis pv. citri reveals novel genetic determinants and regulation mechanisms of biofilm formation.

    Directory of Open Access Journals (Sweden)

    Jinyun Li

    Full Text Available Xanthomonas axonopodis pv. citri (Xac causes citrus canker disease, a major threat to citrus production worldwide. Accumulating evidence suggests that the formation of biofilms on citrus leaves plays an important role in the epiphytic survival of this pathogen prior to the development of canker disease. However, the process of Xac biofilm formation is poorly understood. Here, we report a genome-scale study of Xac biofilm formation in which we identified 92 genes, including 33 novel genes involved in biofilm formation and 7 previously characterized genes, colR, fhaB, fliC, galU, gumD, wxacO, and rbfC, known to be important for Xac biofilm formation. In addition, 52 other genes with defined or putative functions in biofilm formation were identified, even though they had not previously reported been to be associated with biofilm formation. The 92 genes were isolated from 292 biofilm-defective mutants following a screen of a transposon insertion library containing 22,000 Xac strain 306 mutants. Further analyses indicated that 16 of the novel genes are involved in the production of extracellular polysaccharide (EPS and/or lipopolysaccharide (LPS, 7 genes are involved in signaling and regulatory pathways, and 5 genes have unknown roles in biofilm formation. Furthermore, two novel genes, XAC0482, encoding a haloacid dehalogenase-like phosphatase, and XAC0494 (designated as rbfS, encoding a two-component sensor protein, were confirmed to be biofilm-related genes through complementation assays. Our data demonstrate that the formation of mature biofilm requires EPS, LPS, both flagellum-dependent and flagellum-independent cell motility, secreted proteins and extracellular DNA. Additionally, multiple signaling pathways are involved in Xac biofilm formation. This work is the first report on a genome-wide scale of the genetic processes of biofilm formation in plant pathogenic bacteria. The report provides significant new information about the genetic

  2. In silico identification of potential chaperone genes that belong to type III and type IV secretion systems in Xanthomonas axonopodis pv citri

    Directory of Open Access Journals (Sweden)

    Letícia Khater

    2005-01-01

    Full Text Available The secretion of bacterial virulence factors and flagellar components requires the assistance of specific type III and flagellar chaperones. Standard computational annotation of the genome of Xanthomonas axonopodis pv citri, a plant pathogen that causes citrus canker, initially did not identify any genes belonging to these chaperone categories since the primary sequence homology between them was very low. However, in a search for hypothetical proteins with characteristics similar to these chaperones, we have now identified 30 chromosomal and 10 plasmidial potential genes encoding chaperones belonging to types III/IV, and flagellar secretion systems in this organism. The significance of these findings is discussed.

  3. The monofunctional catalase KatE of Xanthomonas axonopodis pv. citri is required for full virulence in citrus plants.

    Directory of Open Access Journals (Sweden)

    María Laura Tondo

    Full Text Available BACKGROUND: Xanthomonas axonopodis pv. citri (Xac is an obligate aerobic phytopathogen constantly exposed to hydrogen peroxide produced by normal aerobic respiration and by the plant defense response during plant-pathogen interactions. Four putative catalase genes have been identified in silico in the Xac genome, designated as katE, catB, srpA (monofunctional catalases and katG (bifunctional catalase. METHODOLOGY/PRINCIPAL FINDINGS: Xac catalase activity was analyzed using native gel electrophoresis and semi-quantitative RT-PCR. We demonstrated that the catalase activity pattern was regulated in different growth stages displaying the highest levels during the stationary phase. KatE was the most active catalase in this phase of growth. At this stage cells were more resistant to hydrogen peroxide as was determined by the analysis of CFU after the exposition to different H(2O(2 concentrations. In addition, Xac exhibited an adaptive response to hydrogen peroxide, displaying higher levels of catalase activity and H(2O(2 resistance after treatment with sub-lethal concentrations of the oxidant. In the plant-like medium XVM2 the expression of KatE was strongly induced and in this medium Xac was more resistant to H(2O(2. A XackatE mutant strain was constructed by insertional mutagenesis. We observed that catalase induction in stationary phase was lost meanwhile the adaptive response to peroxide was maintained in this mutant. Finally, the XackatE strain was assayed in planta during host plant interaction rendering a less aggressive phenotype with a minor canker formation. CONCLUSIONS: Our results confirmed that in contrast to other Xanthomonas species, Xac catalase-specific activity is induced during the stationary phase of growth in parallel with the bacterial resistance to peroxide challenge. Moreover, Xac catalases expression pattern is modified in response to any stimuli associated with the plant or the microenvironment it provides. The catalase Kat

  4. Comparison of PCR,DIA and Pathogenicity Assay for Detection of Xanthomonas axonopodis pv.citri,the Causal Agent of Citrus Bacterial Canker Disease

    Institute of Scientific and Technical Information of China (English)

    WANG Zhong-kang; SUN Xian-yun; YIN You-ping; ZHOU Chang-yong; XIA Yu-xian

    2004-01-01

    Polymerase chain reaction (PCR) approach based on newly designed primers, JYF5/JYR5, was applied for specific detection of Xanthomonas axonopodis pv.citri(Xac). The efficiency and reliability of PCR method were compared with dot immunobinding assay (DIA) and classical pathogenicity test techniques for detecting suspensions of pure cells of Xac and soaking sap of citrus tissues. Detection sensitivity of PCR was about 4.5 cells or 1.56 pg target DNA per reaction which was higher than that of DIA (ca. 450 cells per dot).These three techniques (PCR assay, DIA and Pathogenecity test) could always detect Xac from symptomatic citrus samples. Different performances were obtained from citrus materials without symptoms, and the positive detection frequency was PCR, DIA and pathogenicity test.

  5. The filamentous phage XacF1 causes loss of virulence in Xanthomonas axonopodis pv. citri, the causative agent of citrus canker disease

    Directory of Open Access Journals (Sweden)

    Abdelmonim Ali Ahmad

    2014-07-01

    Full Text Available In this study, filamentous phage XacF1, which can infect Xanthomonas axonopodis pv. citri (Xac strains, was isolated and characterized. Electron microscopy showed that XacF1 is a member of the family Inoviridae and is about 1000 nm long and 16 nm in width. The genome of XacF1 is 7325 nucleotides in size, containing 13 predicted open reading frames (ORFs, some of which showed significant homology to Ff-like phage proteins such as ORF1 (pII, ORF2 (pV, ORF6 (pIII, and ORF8 (pVI. XacF1 showed a relatively wide host range, infecting seven out of 11 strains tested in this study. Frequently, XacF1 was found to be integrated into the genome of Xac strains. This integration occurred at the host dif site (attB and was mediated by the host XerC/D recombination system. The attP sequence was identical to that of Xanthomonas phage Cf1c. Interestingly, infection by XacF1 phage caused several physiological changes to the bacterial host cells, including lower levels of extracellular polysaccharide production, reduced motility, slower growth rate, and a dramatic reduction in virulence. In particular, the reduction in virulence suggested possible utilization of XacF1 as a biological control agent against citrus canker disease.

  6. A plant natriuretic peptide-like molecule of the pathogen Xanthomonas axonopodis pv. citri causes rapid changes in the proteome of its citrus host

    KAUST Repository

    Garavaglia, Betiana S

    2010-03-21

    Background: Plant natriuretic peptides (PNPs) belong to a novel class of peptidic signaling molecules that share some structural similarity to the N-terminal domain of expansins and affect physiological processes such as water and ion homeostasis at nano-molar concentrations. The citrus pathogen Xanthomonas axonopodis pv. citri possesses a PNP-like peptide (XacPNP) uniquely present in this bacteria. Previously we observed that the expression of XacPNP is induced upon infection and that lesions produced in leaves infected with a XacPNP deletion mutant were more necrotic and lead to earlier bacterial cell death, suggesting that the plant-like bacterial PNP enables the plant pathogen to modify host responses in order to create conditions favorable to its own survival.Results: Here we measured chlorophyll fluorescence parameters and water potential of citrus leaves infiltrated with recombinant purified XacPNP and demonstrate that the peptide improves the physiological conditions of the tissue. Importantly, the proteomic analysis revealed that these responses are mirrored by rapid changes in the host proteome that include the up-regulation of Rubisco activase, ATP synthase CF1 ? subunit, maturase K, and ?- and ?-tubulin.Conclusions: We demonstrate that XacPNP induces changes in host photosynthesis at the level of protein expression and in photosynthetic efficiency in particular. Our findings suggest that the biotrophic pathogen can use the plant-like hormone to modulate the host cellular environment and in particular host metabolism and that such modulations weaken host defence. 2010 Garavaglia et al; licensee BioMed Central Ltd.

  7. A plant natriuretic peptide-like molecule of the pathogen Xanthomonas axonopodis pv. citri causes rapid changes in the proteome of its citrus host

    Directory of Open Access Journals (Sweden)

    Ottado Jorgelina

    2010-03-01

    Full Text Available Abstract Background Plant natriuretic peptides (PNPs belong to a novel class of peptidic signaling molecules that share some structural similarity to the N-terminal domain of expansins and affect physiological processes such as water and ion homeostasis at nano-molar concentrations. The citrus pathogen Xanthomonas axonopodis pv. citri possesses a PNP-like peptide (XacPNP uniquely present in this bacteria. Previously we observed that the expression of XacPNP is induced upon infection and that lesions produced in leaves infected with a XacPNP deletion mutant were more necrotic and lead to earlier bacterial cell death, suggesting that the plant-like bacterial PNP enables the plant pathogen to modify host responses in order to create conditions favorable to its own survival. Results Here we measured chlorophyll fluorescence parameters and water potential of citrus leaves infiltrated with recombinant purified XacPNP and demonstrate that the peptide improves the physiological conditions of the tissue. Importantly, the proteomic analysis revealed that these responses are mirrored by rapid changes in the host proteome that include the up-regulation of Rubisco activase, ATP synthase CF1 α subunit, maturase K, and α- and β-tubulin. Conclusions We demonstrate that XacPNP induces changes in host photosynthesis at the level of protein expression and in photosynthetic efficiency in particular. Our findings suggest that the biotrophic pathogen can use the plant-like hormone to modulate the host cellular environment and in particular host metabolism and that such modulations weaken host defence.

  8. Crystallization and preliminary X-ray diffraction analysis of XAC1151, a small heat-shock protein from Xanthomonas axonopodis pv. citri belonging to the α-crystallin family

    Energy Technology Data Exchange (ETDEWEB)

    Hilario, Eduardo; Teixeira, Elaine Cristina; Pedroso, Gisele Audrei; Bertolini, Maria Célia [Departamento de Bioquímica e Tecnologia Química, Instituto de Química, Universidade Estadual Paulista, Araraquara-SP (Brazil); Medrano, Francisco Javier, E-mail: fjmedrano@yahoo.com [Departamento de Cristalografia de Proteínas, Centro de Biologia Molecular Estrutural, Laboratório Nacional de Luz Síncrotron, Caixa Postal 6192, CEP 13084-971, Campinas-SP (Brazil); Departamento de Bioquímica e Tecnologia Química, Instituto de Química, Universidade Estadual Paulista, Araraquara-SP (Brazil)

    2006-05-01

    XAC1151, a small heat-shock protein from X. axonopodis pv. citri belonging to the α-crystallin family, was crystallized using the sitting-drop vapour-diffusion method in the presence of ammonium phosphate. X-ray diffraction data were collected to 1.65 Å resolution using a synchrotron-radiation source. The hspA gene (XAC1151) from Xanthomonas axonopodis pv. citri encodes a protein of 158 amino acids that belongs to the small heat-shock protein (sHSP) family of proteins. These proteins function as molecular chaperones by preventing protein aggregation. The protein was crystallized using the sitting-drop vapour-diffusion method in the presence of ammonium phosphate. X-ray diffraction data were collected to 1.65 Å resolution using a synchrotron-radiation source. The crystal belongs to the rhombohedral space group R3, with unit-cell parameters a = b = 128.7, c = 55.3 Å. The crystal structure was solved by molecular-replacement methods. Structure refinement is in progress.

  9. Alterações metabólicas em plantas de feijão originadas de sementes microbiolizadas por Pseudomonas sp. e inoculadas com Xanthomonas axonopodis pv. phaseoli Metabolic alterations on bean plants originated from microbiolization of seeds with Pseudomonas sp. and inoculated with Xanthomnas axonopodis pv. phaseoli

    Directory of Open Access Journals (Sweden)

    Eliane Gonçalves da Silva

    2009-06-01

    Full Text Available Muitas enzimas estão envolvidas em reações de defesa de plantas contra patógenos. O objetivo deste trabalho foi verificar alterações na atividade de algumas destas enzimas em plantas de feijão originadas de sementes microbiolizadas com um isolado de Pseudomonas do grupo das fluorescentes (isolado DFs842. Sementes de feijão cultivar BRS Valente foram imersas em suspensão salina preparada a partir de crescimento bacteriano com 24 h do isolado de Pseudomonas (OD540=0,5 sabidamente biocontroladora de Xanthomonas axonopodis pv. phaseoli. Como testemunhas, as sementes foram imersas em solução salina (NaCl 0,85%. Após a microbiolização por 5 h a 10ºC, as sementes foram plantadas em vasos contendo uma mistura de solo não esterilizado, areia e esterco bovino (proporção 3:1:1, mantidos em casa de vegetação. A inoculação do patógeno foi realizada na terceira folha verdadeira de todas as plantas, fazendo-se cortes com tesoura imersa em suspensão salina do patógeno (X. axonopodis pv. phaseoli preparada a partir de crescimento de 24 h (OD540=0,4. Câmaras úmidas foram mantidas 24 h antes e após a inoculação. Para o preparo do extrato protéico, as três primeiras folhas verdadeiras foram coletadas individualmente em 5 épocas de coleta distintas: uma, momentos antes da inoculação e as demais nos tempos seis, 24, 72 h e 15 dias após a inoculação. Este extrato protéico serviu de fonte para as determinações do teor de proteínas solúveis totais (PST, atividade da polifenol oxidase (PPO e da peroxidase (PO, as quais foram realizadas por leituras espectrofotométricas. Os resultados demonstraram aumento significativo no teor de PST e na atividade de PPO nas plantas submetidas ao tratamento com isolado DFs842, sendo que, o teor de PST foi o dobro, em relação às plantas não tratadas. Também foi observado que, mesmo antes da inoculação do patógeno o teor de PST e a atividade de PPO nas plantas tratadas estavam bem maiores

  10. 1H HRMAS NMR spectroscopy and chemometrics for evaluation of metabolic changes in citrus sinensis Caused by Xanthomonas axonopodis pv. citri

    International Nuclear Information System (INIS)

    Xanthomonas axonopodis (Xac) bacterium causes one of the most feared and untreatable diseases in citriculture: citrus canker. To understand the response mechanisms of orange trees when attacked by Xac, leaves and fruits of Citrus sinensis were directly evaluated by HRMAS NMR (high resolution magic angle spinning nuclear magnetic resonance) spectroscopy. This technique allows the analysis of samples without laborious pre-treatments and also allows access to important information about chemical composition of samples. The orange tree leaves and fruit peels investigated in this study demonstrated the biochemical changes caused by Xac. Aided by chemometric analysis, the HRMAS NMR results show relevant changes in amino acids, carbohydrates, organic acids and terpenoids content. (author)

  11. Regular LAMP and fast LAMP for the detection of Xanthomonas axonopodis pv.citri%柑橘溃疡病菌的普通LAMP及快速LAMP检测方法的建立

    Institute of Scientific and Technical Information of China (English)

    张仑; 殷幼平; 吴瑜佳; 王中康

    2013-01-01

    This study is aimed to establish the regular LAMP and fast LAMP for the detection of Xanthomonas axonopodis pv.citri and make it useful for the grassroots quarantine departments.A specific region of the genome of X.axonopodis pv.citri was used for the design of regular LAMP and fast LAMP primers; the regular LAMP and fast LAMP detection system were established by optimization of reaction conditions; the specificity of the system was verified using genomic DNA of several reference strains and healthy citrus leaves by using a series of gradient dilution of DNA solution of X.axonopodis pv.citri and bacterial suspension.Bacterial suspension and DNA sensitivity of regular LAMP system reached 2.25 × 104 cfu and 2.03× 10-1 ng,respectively,while those of fast LAMP system reached 2.25 cfu and 2.03× 10-5 ng,respectively.In the specificity test,both regular LAMP and fast LAMP system showed high and identical specificity.The total time for the fast LAMP reaction was within 30 minutes,only half of that for the regular LAMP,greatly improving the efficiency of the analysis.The fast LAMP system was ten thousand times as sensitive as the regular LAMP system.Regular LAMP and fast LAMP for the detection of X.axonopodis pv.citri was successfully established.Regular LAMP and fast LAMP system provide a new,fast and easy way for the detection of X.axonopodis pv.citri.%建立柑橘溃疡病菌的普通LAMP和快速LAMP检测方法,使其能应用于基层检验检疫部门对病害的快速检测.利用柑橘溃疡病菌基因组特有的保守区域设计LAMP引物,通过优化反应条件,建立柑橘溃疡病菌的普通LAMP检测体系;在普通LAMP引物的基础上设计一对环引物,建立柑橘溃疡病菌的快速LAMP检测体系,并以多种参比菌DNA以及健康柑橘叶片基因组DNA为模板对普通LAMP和快速LAMP检测体系的特异性进行了验证,利用柑橘溃疡病菌菌液和DNA溶液梯度稀释液对普通LAMP和快速LAMP检测体系的灵敏度进

  12. Microwave-based Method for Genomic DNA Extraction and Rapid Detection Method from Xanthomonas axonopodis pv.citri%柑桔溃疡病菌基因组DNA的微波法抽提及快速检测

    Institute of Scientific and Technical Information of China (English)

    姚廷山; 周常勇; 胡军华; 冉春; 李鸿筠; 刘浩强; 肖田

    2012-01-01

    利用微波热震惊提取固体表面柑桔溃疡病基因组DNA并加以优化,所得到的基因组DNA可作为PCR反应的模板进行16SrDNA基因有效扩增.与柑桔溃疡病基园组DNA其他抽提方法相比较,微波法更适用于该病的快速检测,具有快速、筒便、费用低廉等特点,且对设备的要求不高,用特异性引物XCF/XCR可实现柑桔溃疡病菌的快速鉴定.%The optimized microwave extraction was conducted to attract the genome of citrus canker disease. The genome extraction method was fast,easy to handle with low cost The extracted DNA was suitable for PCR. The microwave-based method was suitable for fast identification compare to other methods. The method was effective, easy and fast, so it was recommended that the extraction method was applied for the detection of Xanthomonas oxonopodit pv. citri using primers XCF/XCR.

  13. Development of RLK-Derived Molecular Markers Associating with the Resistance to Citrus Canker [Xanthomonas axonopodis pv. Citri (Xac)] Disease%开发与柑桔抗溃疡病基因连锁的由RLK-RGC衍生的分子标记

    Institute of Scientific and Technical Information of China (English)

    向旭; 郑启发; 黄舒; 陈存贤; Frederick G. Gmitter Jr.; 邓占鳌

    2005-01-01

    本文是在先期研究工作的基础上,利用从柑桔与枳属间杂种的基因组DNA所获得的类受体激酶(RLK)的候选抗病基因序列,重新设计引物,对柑桔抗溃疡病材料和感病材料开展以PCR扩增为基础的对比分析,其中一对引物‘19h16/DdeI'的扩增产物经限制性内切酶DdeI酶切,揭示了抗性材料(Ichang Papeda,Meiwa kumquat,Maruhi kumquat and Nagami kumquat)和感病材料(Flying Dragon,Valencia orange and Palestine sweetlime)之间的多态性差异,同时,在C.Ichangensis的自交F1代和Palestine sweetlime× Ichang Papeda的杂交F1代群体中也见明显的多态性差异;对这些F1代个体进行溃疡病病原[Xanthomonas axonopodis pv.Citri(Xac)]接种作抗病性表型鉴定,结果表明,该分子标记‘19h16/DdeI'与柑桔溃疡病抗性密切相关;经纯化测序的结果进一步证明,抗性材料PCR扩增产物具有完全一致的序列和DdeI酶切位点,但感病材料缺少这一DdeI酶切位点;染色体步行(primerwalking)在BAC文库的对应单克隆中获得了一个完整的抗病基因序列,与以前获得的2个抗病基因序列‘17o6RLKP'和‘26m19RLKP'相比,‘19h16RLKP'也具有Xa21抗病基因蛋白的所有特征,包括含有一个信号肽、同样数目的亮氨酸重复序列、跨膜域和激酶域等.基于该序列的开放读码框,发展了特异性更强可靠性更高的另一分子标记,在今后的研究工作中具有较大的应用潜力.%By utilizing the receptor-like kinase (RLK) RGC sequences previously obtained from the genomic DNA of an intergeneric Citrus and Poncirus hybrid, PCR amplification with one pair of new-designed primers was found to reveal polymorphism between the theoretical resistant species (Ichang Papeda, Meiwa kumquat,Maruhi kumquat and Nagami kumquat) and susceptible species (Flying Dragon, Valencia orange and Palestine sweet lime ) and among the self-crossing population of C. Ichangensis and F1 population of Palestine sweet lime

  14. AFLP analysis of Xanthomonas axonopodis and X. arboricola strains used in xanthan production studies reveal high levels of polymorphism

    Directory of Open Access Journals (Sweden)

    Laurí Mayer

    2010-10-01

    Full Text Available Amplified fragment length polymorphism (AFLP was used to analyze the genetic diversity of 14 strains of Xanthomonas arboricola pv. pruni and seven strains of X. axonopodis pv. phaseoli, which are used in xanthan production studies. Relationships identified by the AFLP profiles were assessed for xanthan production capacity, geographical location and host plant. Strains were isolated from 10 different geographic regions in South and Southeast States in Brazil. Data were analyzed for genetic similarity using the Dice coefficient and subjected to UPGMA cluster analysis. A total of 128 AFLP fragments were generated from four primer combinations: EcoRI+C/MseI+0, EcoRI+A/MseI+0, EcoRI+G/MseI+T and EcoRI+G/MseI+A. Of these, 96.1% were polymorphic. X. axonopodis pv. phaseoli (S D = 0.27 was shown to be more polymorphic than X. arboricola pv. pruni (S D = 0.58. All 14 pathovar pruni strains were included in a single main group (S D = 0.58, while the pathovar phaseoli strains were divided into three separate groups, with one group containing five strains (S D = 0.38 and two isolated groups (S D = 0.31 and 0.27 composed of only one strain each. Species were distinguished by three and eight specific AFLP markers present in the pathovar phaseoli and the pathovar pruni, respectively. For the unique strain without xanthan production capacity (X. axonopodis pv. phaseoli str. 48, nine specific AFLP bands were found. There was no evidence that geographic area or host plant influenced genetic heterogeneity. Correlations between AFLP patterns and xanthan production capacity were found in some strains, but were not consistent enough to establish a relationship.

  15. A plant natriuretic peptide-like gene in the bacterial pathogen Xanthomonas axonopodis may induce hyper-hydration in the plant host: a hypothesis of molecular mimicry

    Directory of Open Access Journals (Sweden)

    Sayed Muhammed

    2004-03-01

    Full Text Available Abstract Background Plant natriuretic peptides (PNPs are systemically mobile molecules that regulate homeostasis at nanomolar concentrations. PNPs are up-regulated under conditions of osmotic stress and PNP-dependent processes include changes in ion transport and increases of H2O uptake into protoplasts and whole tissue. Presentation of the hypothesis The bacterial citrus pathogen Xanthomonas axonopodis pv. Citri str. 306 contains a gene encoding a PNP-like protein. We hypothesise that this bacterial protein can alter plant cell homeostasis and thus is likely to represent an example of molecular mimicry that enables the pathogen to manipulate plant responses in order to bring about conditions favourable to the pathogen such as the induced plant tissue hyper-hydration seen in the wet edged lesions associated with Xanthomonas axonopodis infection. Testing the hypothesis We found a Xanthomonas axonopodis PNP-like protein that shares significant sequence similarity and identical domain organisation with PNPs. We also observed a significant excess of conserved residues between the two proteins within the domain previously identified as being sufficient to induce biological activity. Structural modelling predicts identical six stranded double-psi β barrel folds for both proteins thus supporting the hypothesis of similar modes of action. No significant similarity between the Xanthomonas axonopodis protein and other bacterial proteins from GenBank was found. Sequence similarity of the Xanthomonas axonopodis PNP-like protein with the Arabidopsis thaliana PNP (AtPNP-A, shared domain organisation and incongruent phylogeny suggest that the PNP-gene may have been acquired by the bacteria in an ancient lateral gene transfer event. Finally, activity of a recombinant Xanthomonas axonopodis protein in plant tissue and changes in symptoms induced by a Xanthomonas axonopodis mutant with a knocked-out PNP-like gene will be experimental proof of molecular mimicry

  16. 冰糖橙与枸橼 C-05对溃疡病菌生长特性的影响%The Influence of ‘Bingtang’ Sweet Orange or Citron C-05 on the Growth Characteristics of Xanthomonas axonopodis pv. citri

    Institute of Scientific and Technical Information of China (English)

    葛红娟; 龙桂友; 戴素明; 李大志; 李娜; 邓子牛

    2015-01-01

    [Objective]A new inoculation method was used to discuss the difference of the influence of ‘Bingtang’ sweet orange and C-05 on the growth characteristics of Xanthomonas axonopodis pv. citri (Xac) by comparing different influences of leaves on Xac.[Method]The fully expanded leaves with light green of ‘Bingtang’ sweet orange and citron C-05 were sterilized by 75% ethyl alcohol and 1% NaClO, cut and cultured with Xac in the same petri dish to determine the influence of ‘Bingtang’ sweet orange or citron C-05 on the growth of Xac in MT medium or the NYGA medium replaced the middle place of the MT medium (MA). And the leaves’ solution of ‘Bingtang’ sweet orange or citron C-05 were extracted and added with 25%, 50%, and 75% to MT medium to determine the influence on the growth of Xac; also these were added with different ratios to NYGB medium to determine the content of extracellular polysaccharide (EPS) of Xac, respectively. [Result]The leaves of ‘Bingtang’ sweet orange promoted the growth of Xac on MT medium. The proliferation of the strain could be viewed after 1 week, the average diameter of Xac was 0.5 mm larger than CK. After 2 weeks, the average diameter of Xac was 5.27 mm, which was the 3 times of that of CK. From 2 to 3 weeks was the rapid growth stage of Xac, the average diameter of Xac was from 5.27 mm to 13.41 mm, which was more than 5 times of that of CK. After 3 weeks, the Xac cultured with the leaves of ‘Bingtang’ sweet orange in MT medium grew smoothly and steadily. Compared with that of CK, the diameter of Xac cultured with the ‘Bingtang’ sweet orange was very significantly different. The Xac cultured with the leaves of ‘Bingtang’ sweet orange in MA medium was 4.58 mm after 1 day, and that of CK was 6.19 mm. After 3 days of inoculation, the average diameter of Xac cultured with ‘Bingtang’ sweet orange was the same as CK, and there were no significant differences with each other. After 5 days, the Xac cultured with

  17. A plant natriuretic peptide-like gene in the bacterial pathogen Xanthomonas axonopodis may induce hyper-hydration in the plant host: a hypothesis of molecular mimicry

    OpenAIRE

    Sayed Muhammed; Seoighe Cathal; Nembaware Victoria; Gehring Chris

    2004-01-01

    Abstract Background Plant natriuretic peptides (PNPs) are systemically mobile molecules that regulate homeostasis at nanomolar concentrations. PNPs are up-regulated under conditions of osmotic stress and PNP-dependent processes include changes in ion transport and increases of H2O uptake into protoplasts and whole tissue. Presentation of the hypothesis The bacterial citrus pathogen Xanthomonas axonopodis pv. Citri str. 306 contains a gene encoding a PNP-like protein. We hypothesise that this ...

  18. OCCURRENCE OF LEAF SPOTS CAUSED BY FUNGI AND A BACTERIUM ON COTTON CULTIVARS OCORRÊNCIA DE MANCHAS FOLIARES CAUSADAS POR FUNGOS E BACTÉRIA EM CULTIVARES DE ALGODOEIRO

    Directory of Open Access Journals (Sweden)

    Miguel Ferreira Soria

    2008-11-01

    Full Text Available

    The cotton leaf spot diseases caused by fungi and bacteria are a growing problem, leading to an increasing use of fungicides. During the 2000/2001 and 2001/2002 growing seasons, field experiments were carried out in a randomized block design, with five replications, aiming to evaluate the behavior of the cotton cultivars Ita-90, CD-401, CD-402, CD-403, CD-404, Fibermax 986, DeltaOpal, and Facual, as related to leaf spot diseases caused by Stemphylium spp., Alternaria spp., Ramularia areola, and the bacterium Xanthomonas axonopodis pv. malvacearum. The cotton cultivars Ita-90 and Facual were the less susceptible to the Stemphylium/Alternaria complex and R. areola. However, Ita-90 was more susceptible to X. axonopodis pv. Malvacearum. The cultivars with the least incidence of X. axonopodis were CD-403, Fibermax 986, and DeltaOpal. The cotton cultivar Facual presented the lowest yield, while the remaining cultivars showed similar yields.

    KEY-WORDS: Xanthomonas axonopodis pv. Malvacearum; Stemphylium spp; Alternaria spp; Ramularia areola.

    As manchas foliares causadas por fungos e bactérias no algodoeiro são um problema cada vez mais grave, levando à utilização, cada vez maior, de fungicidas para controlá-las. Nas safras de 2000/2001 e 2001/2002, foram realizados experimentos m campo, em delineamento de blocos ao acaso, com cinco epetições, objetivando avaliar o comportamento das

  19. PV Emulator

    OpenAIRE

    Pelin, Denis; Jukić Antolović, Jelena; Rapčan, Vjekoslav

    2014-01-01

    The photovoltaic emulator (PV emulator) described in the paper is used for laboratory exercises in the courses Renewable Energy Sources and Emergency/Standby Power Supply Systems in the Graduate (Master) Studies in Electrical Engineering – Power Systems Engineering and Principles of Power Electronics in the Undergraduate (Bachelor) Studies in Electrical Engineering as well as for scientific research relating to setting an optimal photovoltaic system for regional climatic elements. The paper g...

  20. Rizobactérias no controle da mancha angular do algodoeiro Rhizobacteria to control cotton bacterial blight

    Directory of Open Access Journals (Sweden)

    Alessandra Keiko Nakasone Ishida

    2008-02-01

    Full Text Available Avaliou-se o potencial de rizobactérias na indução de resistência do algodoeiro à Xanthomonas axonopodis pv. malvacearum. Após o isolamento das rizobactérias, foram selecionados os isolados capazes de reduzir os sintomas da mancha angular bacteriana em casa de vegetação, os quais foram aplicados espacialmente separados do patógeno desafiador. Os melhores isolados foram testados quanto à capacidade de reduzir os sintomas da ramulose e da murcha de Verticillium e de inibir diretamente os patógenos in vitro. Do total de 123 isolados de rizobactérias foram selecionados cinco, L2-1 (Bacillus cereus, MT5-6 (Bacillus cereus, L2-2 (Achromobacter xylosoxidans, MT5-5 (Bacillus cereus e MT5-11 (Brevibacterium sp., os quais apresentaram controle da mancha angular acima de 40%, em relação à testemunha. Nenhum isolado reduziu a severidade da ramulose e da murcha de Verticillium em relação à testemunha, nem apresentou efeito inibitório direto in vitro a X. axonopodis pv. malvacearum e Colletotrichum gossypii var. cephalosporioides. Para V. dahliae, apenas o isolado L2-1 apresentou efeito inibitório.The potential of rhizobacteria was evaluated for resistance induction against Xanthomonas axonopodis pv. malvacearum. After isolation, the rhizobacteria were screened for the reduction of angular leaf spot severity under greenhouse conditions. They were spatially separated from the challenging pathogen. The best isolates were tested for the capacity to reduce ramulose and Verticillium wilt severity and directly inhibit pathogens in vitro. From a total of 123 rhizobacterial isolates, five were selected, L2-1 (Bacillus cereus, MT5-6 (Bacillus cereus, L2-2 (Achromobacter xylosoxidans, MT5-5 (Bacillus cereus and MT5-11 (Brevibacterium sp., which showed angular leaf spot control above 40% as compared to the control. The tested isolates neither reduced the severity of ramulose and verticillium wilt compared to the control nor showed in vitro direct

  1. Influência da natureza do rejeito agroindustrial fermentado por Xanthomonas axonopodis pv. manihotis nas propriedades das gomas xantana resultantes

    Directory of Open Access Journals (Sweden)

    Denilson de Jesus Assis

    2014-01-01

    Full Text Available Um destino para resíduos agro-industriais é usá-los como substratos fermentescíveis, diminuindo o custo na produção de produtos com alto valor agregado. Este trabalho avaliou a influência da natureza dos resíduos fermentescíveis e das cepas de Xanthomonas sobre a produção e propriedades do biopolímero resultante. A produção foi realizada em agitador orbital (250 rpm / 28 °C / 120 h por fermentação de sacarose (controle, glicerina residual do biodiesel e resíduo líquido de sisal. Tanto a composição do substrato como as cepas mostraram um forte efeito sobre a produção (0,36-2,40 gL- 1, viscosidade aparente (13,73 para 36,31 mPa.s e massa molecular (2,1-5,9 × 10(6 Da da goma de xantana resultante, não influenciando o comportamento pseudoplástico de soluções aquosas dos biopolímeros.

  2. Influência da natureza do rejeito agroindustrial fermentado por Xanthomonas axonopodis pv. manihotis nas propriedades das gomas xantana resultantes

    OpenAIRE

    Denilson de Jesus Assis; Larissa Alves de Sousa Costa; Márcio Inomata Campos; Carolina de Oliveira Souza; Janice Izabel Druzian; Itaciara Lazorra Nunes; Francine Ferreira Padilha

    2014-01-01

    Um destino para resíduos agro-industriais é usá-los como substratos fermentescíveis, diminuindo o custo na produção de produtos com alto valor agregado. Este trabalho avaliou a influência da natureza dos resíduos fermentescíveis e das cepas de Xanthomonas sobre a produção e propriedades do biopolímero resultante. A produção foi realizada em agitador orbital (250 rpm / 28 °C / 120 h) por fermentação de sacarose (controle), glicerina residual do biodiesel e resíduo líquido de sisal. Tanto a com...

  3. Transcriptome Alterations Resulting From Infection And Recovery Of Leafy Spurge To Cassava Bacterial Blight (Xanthomonas axonopodis pv. Manihotis)

    Science.gov (United States)

    Leafy spurge is a perennial rangeland weed that has been developed as a model weed system. An extensive EST database and cDNA microarrays containing more than 23,000 unigenes have been developed and used to characterize a variety of physiological processes from bud dormancy to drought stress and rec...

  4. Fire resistant PV shingle assembly

    Science.gov (United States)

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  5. Building brighter PV business

    International Nuclear Information System (INIS)

    The current status and future prospects of the UK market for solar photovoltaic (PV) electricity are briefly discussed. Through the Department of Trade and Industry (DTI), the UK Government has supported research and development (R and D) into PV for a number of years. This programme has now been extended to demonstrating PV systems on houses. Phase 2 - the domestic field trial programme - aims to monitor the performance of individual systems and the impact on a cluster of systems on the electricity network. New funding had allowed a trebling of the size of this programme, which involves both private developers and housing associations. The DTI is also working to promote PV on commercial buildings, eg the installation of BP Solar PV systems at BP petrol stations. The PV industry in the UK is technically strong and is working to overcome the barriers in the UK to greater uptake of the technology (including cost, conservatism, legal requirements and metering practices). Improvements are expected in a number of recent initiatives in the electricity industry to boost PV use and the PV industry is lobbying for PV to be included in the Enhanced Capital Allowances (ECA) scheme

  6. PV ready roofing systems

    International Nuclear Information System (INIS)

    The integration of PV technology into roofs of houses has become very popular in the United States, Japan, Germany and The Netherlands. There could be a considerable market in the UK for these systems, given the large number of houses that are projected to be built in the next 10 years, and taking account of increased awareness of energy issues. A significant proportion of the market share of annual installed PV is for solar PV systems installed into homes (currently 15%), this is expected to rise to 23% (900MW) by 2010. The grid connected roof and building mounted facade systems represent the fastest growing market for PV systems in Europe. In conclusion, therefore, innovative approached for fixing PV technology onto roofs have been identified for both domestic roofs and for the commercial sector. With reference to production methodologies within the roofing industry, both approaches should be capable of being designed with PV-ready connections suitable for fixing PV modules at a later date. This will help overcome the key barriers of cost of installation, skills required and the lack of retrofit potential. Based on the results of this project, Sustainable Energy together with PV Systems are keen to take forward the full research and development of PV-ready systems for both the domestic and commercial sectors

  7. The PV market

    International Nuclear Information System (INIS)

    This paper forecasts the photovoltaic (PV) market growth for the 1990s. Ten years of PV history are reviewed and used to establish market trends in terms of average selling price (ASP) and kilowatts shipped by market segment. The market is segmented into indoor consumer, stand-alone, and grid-connected applications. Indoor consumer presently represents a saturated market and is fairly predictable. The stand-alone market (i.e. not connected to the utility grid) is fairly stable and predictable. The utility PV market however is highly dependent on a number of market factors such as the cost of conventional energy the cost of PV systems utility acceptance of PV and regulatory controls. Government and institutional regulations, environmental issues, and OPEC and Middle East politics will have the greatest impact on the cost of conventional fuels. Private and federal investment in PV technology development could have a significant impact on the cost of PV systems. Forecasts are provided through the year 2000 for indoor consumer stand-alone and utility markets

  8. Grid integrated distributed PV (GridPV).

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J.; Coogan, Kyle [Georgia Institute of Technology, Atlanta, GA

    2013-08-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functions are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in the OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function in the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  9. Batteries in PV systems

    OpenAIRE

    Mohedano Martínez, Javier Bernabé

    2011-01-01

    This report presents fundamentals of battery technology and charge control strategies commonly used in stand-alone photovoltaic (PV) Systems,with an introduction on the PV Systems itself. This project is a compilation of information from several sources, including research reports and data from component manufacturers. Comparisons are given for various battery technologies, and considerations for battery subsystem design, auxiliary systems, maintenance and safety are discussed. Daily operatio...

  10. PV-WEB: internet-based PV information tool

    Energy Technology Data Exchange (ETDEWEB)

    Cowley, P.

    2003-07-01

    This report gives details of a project to create a web-based information system on photovoltaic (PV) systems for the British PV Association (PV-UK) for use by decision makers in government, the utilities, and the housing and construction sectors. The project, which aims to provide an easily accessible tool for UK companies, promote PV technology, increase competitiveness, and identify market opportunities, is described. The design of the web site and its implementation and the evolution are discussed, along with the maintenance of the site by PV-UK and the opportunities offered to PV-UK Members.

  11. PV-WEB: internet-based PV information tool

    International Nuclear Information System (INIS)

    This report gives details of a project to create a web-based information system on photovoltaic (PV) systems for the British PV Association (PV-UK) for use by decision makers in government, the utilities, and the housing and construction sectors. The project, which aims to provide an easily accessible tool for UK companies, promote PV technology, increase competitiveness, and identify market opportunities, is described. The design of the web site and its implementation and the evolution are discussed, along with the maintenance of the site by PV-UK and the opportunities offered to PV-UK Members

  12. Global PV Market Development

    International Nuclear Information System (INIS)

    The dawn of 2009 saw several events which caused major turbulence in the global photovoltaic industry. In 2008 the Spanish PV market grew beyond all expectations and even outranked Germany as the world's number one market. However, the promotion scheme was modified and a market cap was introduced in 2009, cutting back the maximum capacity to be installed to about the level of 2007. In addition, the industry is facing an oversupply of PV modules and a harsh recession which is significantly affecting the traditionally strong PV markets. International photovoltaic companies are challenged by a changing market situation: all of a sudden, competition has increased significantly, pushing the customer to the fore. As a result, a consolidation process is expected within the PV industry worldwide. However, the story is not all negative. In the U.S., the election of Barack Obama may be seen as the starting signal for a massive expansion in PV, likely to bring the country to first place globally within the next five years. Furthermore, different markets and market segments are being opened up - especially in Europe - thanks to the gradual arrival of generation parity and new PV support mechanisms. EuPD Research has observed and studied international PV markets since its foundation. The information included in the presentation is based on a wide range of quantitative and qualitative studies that EuPD Research has conducted in the key markets since 2002. Florian Schmidt, EuPD Research's Head of Product Management, will give an overview of the global PV market and how it is developing in this crucial year 2009. Aspects such as technology development, production capacities and the demand side will be included, with a special emphasis on the European PV markets. So far Chinese PV companies have often benefited from the booming PV markets in Europe, above all Germany and Spain. Due to the lack of domestic market, the Chinese industry strongly depends on the export and is

  13. PV power forecast using a nonparametric PV model

    OpenAIRE

    Pinho-Almeida, Marcelo; Perpiñan Lamigueiro, Oscar; Narvarte Fernandez, Luis

    2015-01-01

    Forecasting the AC power output of a PV plant accurately is important both for plant owners and electric system operators. Two main categories of PV modeling are available: the parametric and the nonparametric. In this paper, a methodology using a nonparametric PV model is proposed, using as inputs several forecasts of meteorological variables from a Numerical Weather Forecast model, and actual AC power measurements of PV plants. The methodology was built upon the R environment and uses Quant...

  14. Investors favour PV over CSP

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, Lisa; Smith, Reid

    2011-07-01

    A couple of years ago, CSP seemed to be the utility-scale solar electricity of the future. Now costs for PV systems have declined so much quicker that some investors have changed their plans from CSP to PV. (orig.)

  15. Firefighter Safety for PV Systems

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Sera, Dezso; Spataru, Sergiu;

    2015-01-01

    An important and highly discussed safety issue for photovoltaic (PV) systems is that as long as the PV panels are illuminated, a high voltage is present at the PV string terminals and cables between the string and inverters that is independent of the state of the inverter's dc disconnection switc....... The presence of these energized conductors on the dc side of the PV system can pose a danger to anyone performing maintenance or firefighting....

  16. PV investment in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Hueser, Pius [Nova Energy GmbH, (Switzerland)

    2007-06-15

    This presentation is mainly about how the PV market in Europe has been growing, and which elements are going to determine if this market succeed or failed not only in Europe but also in the rest of the world. In the first part of this presentation, it is mentioned how in 2005 the development of some PV technologies triggered the PV market growth without any marketing control. Then, there are explained the aspects that changed such situation out of control, therefore, it emerged the beginning of the consolidation of this market. There are briefly explained those factors that are going to determine if this market succeed or failed in the future. Finally, there are given examples of some the PV investments. [Spanish] Esta presentacion habla principalmente de la manera en como ha crecido el Mercado de sistemas fotovoltaicos en Europa, asi tambien se mencionan los elementos fundamentales que determinaran el exito o fracaso de este mercado, no solamente en Europa sino tambien en el resto del mundo, en un futuro. En la primera parte de esta presentacion, se describe como en el 2005, debido al desarrollo de algunas tecnologias fotovoltaicas se desencadeno el crecimiento desenfrenado del mercado fotovoltaico. Despues, se explican los aspectos que hicieron que dicho crecimiento tomara su curso, teniendo como resultado el inicio de un mercado mas consolidado. Se explican brevemente los factores que determinaran si este mercado encuentra el exito o el fracaso en un futuro. Finalmente, se dan ejemplos de algunas adquisiciones fotovoltaicas.

  17. Testing for PV Reliability (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Bansal, S.

    2014-09-01

    The DOE SUNSHOT workshop is seeking input from the community about PV reliability and how the DOE might address gaps in understanding. This presentation describes the types of testing that are needed for PV reliability and introduces a discussion to identify gaps in our understanding of PV reliability testing.

  18. PV potential and potential PV rent in European regions

    DEFF Research Database (Denmark)

    Hansen, Anders Chr.; Thorn, Paul

    2013-01-01

    The paper provides a GIS based model for assessing the potentials of photovoltaic electricity in Europe by NUTS 2 regions. The location specific energy potential per PV-­‐panel area is estimated based on observations of solar irradiation, conversion efficiency, levelised costs and the social value...... of PV-­‐electricity. Combined with the potential density of PV-­‐panel area based on land cover and environental restrictions, the PV energy potential and the potential PV ressource rent is calculated. These calculations enbable the model to estimate the regional patterns at NUTS 2 level of the...

  19. PV water pumping: NEOS Corporation recent PV water pumping activities

    Energy Technology Data Exchange (ETDEWEB)

    Lane, C.

    1995-11-01

    NEOS Corporation has been very active in PV-powered water pumping, particularly with respect to electric utilities. Most of the recent activity has been through the Photovoltaic Services Network (PSN). The PSN is an independent, not-for-profit organization comprised of all types of electric utilities: rural electric coops, public power districts, investor-owned utilities, and power marketing agencies. The PSN`s mission is to work pro-actively to promote utility involvement in PV through education and training. PV information is distributed by the PSN in three primary forms: (1) consultation with PSN technical service representatives: (2) literature generated by the PSN; and (3) literature published by other organizations. The PSN can also provide assistance to members in developing PV customer service programs. The PSN`s product support activities include consolidation of information on existing packaged PV systems and facilitation of the development of new PV product packages that meet utility-defined specifications for cost performance, and reliability. The PSN`s initial product support efforts will be focused on commercially available packaged PV systems for a variety of off-grid applications. In parallel with this effort, if no products exist that meet the PSN`s functional specifications, the PSN will initiate the second phase of product development support process by encouraging the development of new packaged systems. Through these services and product support activities, the PSN anticipates engaging all segments for the PV industry, thus providing benefits to PV systems suppliers as well as local PV service contractors.This paper describes field testing of pv power systems for water pumping.

  20. Outdoor PV Degradation Comparison

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, D. C.; Smith, R. M.; Osterwald, C. R.; Gelak, E.; Kurtz, S. R.

    2011-02-01

    As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output; may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined; accurately. At the Performance and Energy Rating Testbed (PERT) at the Outdoor Test Facility (OTF) at the; National Renewable Energy Laboratory (NREL) more than 40 modules from more than 10 different manufacturers; were compared for their long-term outdoor stability. Because it can accommodate a large variety of modules in a; limited footprint the PERT system is ideally suited to compare modules side-by-side under the same conditions.

  1. Sensorless PV Array Diagnostic Method for Residential PV Systems

    DEFF Research Database (Denmark)

    Sera, Dezso; Spataru, Sergiu; Mathe, Laszlo; Kerekes, Tamas; Teodorescu, Remus

    This work proposes a temperature and irradiance sensorless diagnostic method suitable for small residential PV installations, focusing on detection of partial shadows. The method works by detection of failures in crystalline silicone PV arrays by concomitant monitoring of some of their key...

  2. Interband cascade (IC) photovoltaic (PV) architecture for PV devices

    Science.gov (United States)

    Yang, Rui Q.; Tian, Zhaobing; Mishima, Tetsuya D.; Santos, Michael B.; Johnson, Matthew B.; Klem, John F.

    2015-10-20

    A photovoltaic (PV) device, comprising a PV interband cascade (IC) stage, wherein the IC PV stage comprises an absorption region with a band gap, the absorption region configured to absorb photons, an intraband transport region configured to act as a hole barrier, and an interband tunneling region configured to act as an electron barrier. An IC PV architecture for a photovoltaic device, the IC PV architecture comprising an absorption region, an intraband transport region coupled to the absorption region, and an interband tunneling region coupled to the intraband transport region and to the adjacent absorption region, wherein the absorption region, the intraband transport region, and the interband tunneling region are positioned such that electrons will flow from the absorption region to the intraband transport region to the interband tunneling region.

  3. PV in a sports arena; PV im Hexenkessel

    Energy Technology Data Exchange (ETDEWEB)

    Hoeche, B.

    2008-05-19

    The German soccer club Werder Bremen is reconstructing its stadium. Apart from higher spectator comfort and a better atmosphere, there will also be PV systems on the roof and external walls of the arena. (orig.)

  4. Speedometers for PV generators; Drehzahlmesser fuer PV-Generatoren

    Energy Technology Data Exchange (ETDEWEB)

    Fritze, Peter; Weinreich, Bernhard [Solarschmiede GmbH, Muenchen (Germany). Engineering-Abt.

    2011-05-31

    To measure the generator power of an installed PV system, it is not enough to look into the specifications of hte module producers. Fast and independent data can be provided by characteristic curve meters.

  5. Xanthan Gum Removal for 1H-NMR Analysis of the Intracellular Metabolome of the Bacteria Xanthomonas axonopodis pv. citri 306

    Directory of Open Access Journals (Sweden)

    Vanessa R. Pegos

    2014-04-01

    Full Text Available Xanthomonas is a genus of phytopathogenic bacteria, which produces a slimy, polysaccharide matrix known as xanthan gum, which involves, protects and helps the bacteria during host colonization. Although broadly used as a stabilizer and thickener in the cosmetic and food industries, xanthan gum can be a troubling artifact in molecular investigations due to its rheological properties. In particular, a cross-reaction between reference compounds and the xanthan gum could compromise metabolic quantification by NMR spectroscopy. Aiming at an efficient gum extraction protocol, for a 1H-NMR-based metabolic profiling study of Xanthomonas, we tested four different interventions on the broadly used methanol-chloroform extraction protocol for the intracellular metabolic contents observation. Lower limits for bacterial pellet volumes for extraction were also probed, and a strategy is illustrated with an initial analysis of X. citri’s metabolism by 1H-NMR spectroscopy.

  6. Xanthan Gum Removal for 1H-NMR Analysis of the Intracellular Metabolome of the Bacteria Xanthomonas axonopodis pv. citri 306

    OpenAIRE

    Pegos, Vanessa R.; Canevarolo, Rafael R.; Sampaio, Aline P.; Andrea Balan; Ana C. M. Zeri

    2014-01-01

    Xanthomonas is a genus of phytopathogenic bacteria, which produces a slimy, polysaccharide matrix known as xanthan gum, which involves, protects and helps the bacteria during host colonization. Although broadly used as a stabilizer and thickener in the cosmetic and food industries, xanthan gum can be a troubling artifact in molecular investigations due to its rheological properties. In particular, a cross-reaction between reference compounds and the xanthan gum could compromise metabolic quan...

  7. PSCAD Modules Representing PV Generator

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Singh, M.; Gevorgian, V.

    2013-08-01

    Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

  8. Characterization of Xanthomonas spp. strains by bacteriocins Caracterização de isolados de Xanthomonas spp. por bacterocinas

    Directory of Open Access Journals (Sweden)

    Marcel Bonini

    2007-03-01

    Full Text Available Twenty-five strains of Xanthomonas axonopodis pv. citri and 14 strains of Xanthomonas spp. were tested for bacteriocin production. X. axonopodis pv. passiflorae strains were sensitive to the bacteriocins produced by the 25 X. axonopodis pv. citri strains evaluated in this study while strains of X. axonopodis pv. manihotis and X. campestris pv. campestris showed variable sensitivity. Only five of the 25 X. axonopodis pv. citri strains were not inhibited by the bacteriocins produced by the two X. axonopodis pv. passiflorae strains. The bacteriocins produced by the Xanthomonas axonopodis pv. citri (FDC-806 and X. axonopodis pv. passiflorae (Mar-2850 A strains were thermolabile, resistant to lysozyme and sensitive to DNAse. The bacteriocin produced by X. axonopodis pv. passiflorae was resistant to the action of proteinase K, trypsin and RNAse while the bacteriocin produced by X. axonopodis pv. citri was sensitive to these enzymes. The bacteriocins produced by X. axonopodis pv. passiflorae and X. axonopodis pv. citri were called passifloricin and citricin, respectively.Vinte e cinco isolados de Xanthomonas axonopodis pv. citri e 14 isolados de Xanthomonas spp. foram comparados a fim de verificar a capacidade de produção de bacteriocina e a sua sensibilidade. Isolados de X. axonopodis pv. passiflorae foram sensíveis às bacteriocinas produzidas por 25 isolados de X. axonopodis pv. citri avaliados e os isolados de X. axonopodis pv. manihotis e X. campestris pv. campestris apresentaram sensibilidade variável. Dos 25 isolados de X. axonopodis pv. citri apenas cinco não foram inibidos pelas bacteriocinas produzidas por dois isolados de X. axonopodis pv. passiflorae. As bacteriocinas produzidas pelos isolados de X. axonopodis pv. citri (FDC-806 e de X. axonopodis pv. passiflorae (Mar-2850 A foram termolábeis e resistentes à lisozima e sensíveis a DNAse. A bacteriocina produzida pelo isolado de X. axonopodis pv. passiflorae foi resistente à a

  9. Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Ainsworth, Nathan; Gotseff, Peter; Baker, Kyri

    2016-05-05

    A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed study could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.

  10. PV solar system feasibility study

    International Nuclear Information System (INIS)

    Highlights: ► This research studies the feasibility of PV solar systems. ► The aim is to develop the theory and application of a hybrid system. ► Relevant research topics are reviewed and some of them are discussed in details. ► A prototype of the PV solar system is designed and built. - Abstract: This research studies the feasibility of PV solar systems and aims at developing the theory and application of a hybrid system that utilizes PV solar system and another supporting source of energy to provide affordable heating and air conditioning. Relevant research topics are reviewed and some of them are discussed in details. Solar heating and air conditioning research and technology exist in many developed countries. To date, the used solar energy has been proved to be inefficient. Solar energy is an abundant source of energy in Jordan and the Middle East; with increasing prices of oil this source is becoming more attractive alternative. A good candidate for the other system is absorption. The overall system is designed such that it utilizes solar energy as a main source. When the solar energy becomes insufficient, electricity or diesel source kicks in. A prototype of the PV solar system that operates an air conditioning unit is built and proper measurements are collected through a data logging system. The measured data are plotted and discussed, and conclusions regarding the system performance are extracted.

  11. Economic PV - a shift in thinking

    International Nuclear Information System (INIS)

    This article argues that photovoltaic (PV) technology is already economically viable contrary to current opinion. A table of world PV module shipments for 1990 to 1998 by market sector is presented, and use of PV modules in consumer electronics such as calculators, battery trickle chargers, and garden lights; in communications and signals (eg. microwave repeaters, cellular communication); and in the residential sector in fluorescent lights, radios etc. are discussed. The early adopters of PV technology, and the value placed on PV devices by consumers are considered. Details of PV manufacturing costs for 1997, and forecasts for 2000 and 2010 are tabulated

  12. Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, L.; Gostein, M.; Emery, K.

    2012-09-01

    As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PV reference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as the incident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

  13. Solar PV. Innovators talking; Zon PV. Innovators aan het woord

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-02-15

    Qualitative studies have been conducted of the results of completed projects focused on energy innovation, spread over the seven themes of the top sector Energy: Energy saving in industry, Energy conservation in the built environment, Gas, Bio-energy, Smart grids, Offshore Wind, Solar PV. This provides insight into the follow-up activities and lessons of some EOS (Energy Research Subsidy) completed projects with the aim to inspire, connect and strengthen the TKIs (Topconsortia for Knowledge and Innovation) and individual companies and researchers working on energy innovation. This report concerns the research on solar PV [Dutch] Er is een kwalitatief onderzoek uitgevoerd naar de resultaten van afgeronde projecten gericht op energie-innovatie, verdeeld over de zeven thema's van de topsector Energie: Energiebesparing in de industrie; Energiebesparing in de gebouwde omgeving; Gas; Bio-energie; Smart grids; Wind op zee; Zon-pv. Daarmee wordt inzicht gegeven in de vervolgactiviteiten en lessen van een aantal afgesloten EOS-projecten (Energie Onderzoek Subsidie) met het oog op het inspireren, verbinden en versterken van de TKI's (Topconsortia voor Kennis en Innovatie) en individuele bedrijven en onderzoekers die werken aan energie-innovatie. Dit rapport betreft het onderzoek naar zon PV.

  14. Photovoltaics for Buildings Cutting-Edge PV

    International Nuclear Information System (INIS)

    Photovoltaic (PV) technology development for building-integrated applications (commonly called PV for Buildings) is one of the fastest growing areas in the PV industry. Buildings represent a huge potential market for photovoltaics because they consume approximately two-thirds of the electricity consumed in the US. The PV and buildings industries are beginning to work together to address issues including building codes and standards, integration, after-market servicing, education, and building energy efficiency. One of the most notable programs to encourage development of new PV-for-buildings products is the PV:BONUS program, supported by the US Department of Energy. Demand for these products from building designers has escalated since the program was initiated in 1993. This paper presents a range of PV-for-buildings issues and products that are currently influencing today's PV and buildings markets

  15. Developments in photovoltaic solar energy (PV)

    International Nuclear Information System (INIS)

    The current state of affairs and expected developments concerning photovoltaic solar energy (PV) are described in this report. PV is considered to be one of the most important renewable energy sources for the coming century. PV technology is relatively mature, but commercial development is still at an early stage, largely due to the high cost of electricity from PV. Various initiatives to quickly and substantially reduce costs by increasing the scale of production and stimulating the market are being developed

  16. PV supply chain growing pains

    International Nuclear Information System (INIS)

    This article discussed issues involving the supply chain for photovoltaic (PV) equipment that is emerging in Ontario as a result of the Feed-in-Tariff (FIT) program that was launched in late 2009. The rapidly developing PV supply chain may not be taking a sustainable path. The domestic-content requirement is making manufacturers outlay capital to set up manufacturing in Ontario without reliable market data. Only a small number of dealer/installers have any meaningful experience designing and installing grid-tie PV. Until recently, wholesale distributors designed and supplied most grid-tie PV systems in Canada, and solar dealers/installers or electricians or electrical contractors did the installation. Instead of selling directly to dealer/installers, solar manufacturers should develop strong relationships with wholesalers, who have system design experience and product training. This would allow manufacturers to focus on their core strength, reach more customers, and keep lower inventory levels. Wholesale distributors in turn provide dealer/installers with expertise in product and system design, training from a range of manufacturers, marketing and logistics support, and immediate access to inventory. Manufacturers generally lack appropriate accounting, engineering, marketing, and logistics services to deal with a multitude of active accounts, and they are not structured to work with architects and engineers to do complete system design. Partnering with wholesale distributors allows manufacturers to take on the residential and small-scale commercial sectors by building brand awareness and increasing market share and sales across Canada. 2 figs.

  17. Grid Integrated Distributed PV (GridPV) Version 2.

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J.; Coogan, Kyle

    2014-12-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functio ns are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in th e OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function i n the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  18. Lightweight IMM PV Flexible Blanket Assembly

    Science.gov (United States)

    Spence, Brian

    2015-01-01

    Deployable Space Systems (DSS) has developed an inverted metamorphic multijunction (IMM) photovoltaic (PV) integrated modular blanket assembly (IMBA) that can be rolled or z-folded. This IMM PV IMBA technology enables a revolutionary flexible PV blanket assembly that provides high specific power, exceptional stowed packaging efficiency, and high-voltage operation capability. DSS's technology also accommodates standard third-generation triple junction (ZTJ) PV device technologies to provide significantly improved performance over the current state of the art. This SBIR project demonstrated prototype, flight-like IMM PV IMBA panel assemblies specifically developed, designed, and optimized for NASA's high-voltage solar array missions.

  19. The unstoppable rise of photovoltaic solar energy: PV vs. PV

    OpenAIRE

    Luque López, Antonio

    2012-01-01

    Photovoltaic (PV) solar energy has been growing during the last decade an explosive rate. Last year (2011) the solar cell production amounted to more than 37 GW. It is the energy technology most installed nowadays. The power generated by the 37 GW is similar to the one generated by about 7 nuclear units of 1 GW each. The solar industry is already a huge industry dominated by Asian countries led by China. It is not anymore a promise. It is just a reality.

  20. Injuries caused by citrus leafminer (Phyllocnistis citrella exacerbate citrus canker (Xanthomonas axonopodis pv. citri infection Injúrias da larva minadora dos citros (Phyllocnistis citrella intensificam a infecção por cancro cítrico (Xanthomonas axonopodis pv. citri

    Directory of Open Access Journals (Sweden)

    Waldir C. Jesus Junior

    2006-06-01

    Full Text Available After the introduction of citrus leafminer in São Paulo State, an increase in the number of new plants infected with citrus canker has been observed. The interaction between these two organisms is known, but there is no information about how the leafminer damage intensifies citrus canker incidence and severity. The objectives of this paper were to evaluate the effects of leafminer damage in citrus canker infection and its influence on the monocyclic components of the disease on Citrus limonia. Higher incidence of diseased plants, AUDPC (area under the disease progress curve, disease severity and shorter incubation periods were observed in plants inoculated after insect infestation. These factors explain the association found between the higher citrus canker intensity and the damage caused by the insect and show, albeit partially, the consequences of these changes in the spread of the pathogen under natural conditions of infection.Após a constatação da larva minadora dos citros no Estado de São Paulo foi observado um aumento no número de novas plantas infectadas pelo cancro cítrico. Apesar da interação existente entre o cancro cítrico e a larva minadora dos citros ser conhecida já há alguns anos, não há informações que permitam explicar claramente os aumentos observados na incidência e severidade do cancro cítrico quando de sua associação com as injúrias provocadas pelo inseto. Desta forma, no presente trabalho foram avaliados os efeitos de injúrias da larva minadora dos citros na infecção por cancro cítrico e a influência da larva minadora nos componentes monocíclicos da doença em Citrus limonia. Foram observadas maiores incidências de plantas doentes, área abaixo da curva de progresso da doença (AACPD, severidade da doença e menores períodos de incubação quando a inoculação ocorreu em plantas infestadas pela larva minadora dos citros. Esses fatores explicam a associação encontrada entre a maior intensidade dos sintomas da doença e as injúrias do inseto e revelam, ainda que parcialmente, as conseqüências destas mudanças na disseminação do patógeno sob condições naturais de infecção.

  1. 100 KW pv system design

    International Nuclear Information System (INIS)

    This paper reports the design of a 100kw photovolatic (PV) system for 10,000 ft/sup 2/ roof building. It explain the necessary design steps for medium power PV system specifications of associated accessories for large size building solar electrification. A comparison between various solar technologies and their ancillary anchors is provided to guide the young electric power and renewable energy engineers. It is to prove that hybrid photovolatic thermal (PVT) technology is more efficient than simple photovolatic (PV), photovolatic concentrator (PVC) or stand-alone solar thermal heating systems. We have been using fossil fuels from 1859 to 2009. Oil triggered population growth rate which in turn increased energy demand for iil. A 200 years close loop positive feedback has amplified oil production rate for few thousand barrels to 86-87 billion barrels. Today the world population is burning oil at rate of 1000 barrels/sec. The oil reserves are likely to end by 2050 (worst case) or 2100 (best case). At 1.7% growth rate the current global population might double to 12 billion barrels and electric power demand will increase from current 15 TW to TW. Unfortunately oil reserves would be breathing last and global warning would be at its climax. To cope with upcoming power, water water and energy cataclysms, it is more than essential to go for sustainable and renewable and renewable energy education and lifestyles. I hope this design venture will create interest among power and energy students, engineers and professional engine. (author)

  2. Photovoltaics: PV takes off the UK

    International Nuclear Information System (INIS)

    Despite historical ups and downs, there is still ambition to bring increasingly efficient photovoltaic (PV) systems to the market. PV for major remote telecommunications systems is now an established part of the market, many mobile phone systems are powered by PV and there is potential for increased use of home solar systems, especially in developing countries. Over the past few years, building-integrated PV (BIPV) has been on the increase. In 1999, global production from PV exceeded 200 MW and the UK installed capacity was greater than 1 MW. BIPV is a fast growing market and its characteristics and advantages are discussed. PV installations at Nottingham University, Greenwich Pavilion, BP Amoco Sunbury, Baglan Bay, BP filling stations, and Sainsbury's are described

  3. A computer program for PV systems analysis

    International Nuclear Information System (INIS)

    A computer program for analyzing solar cells and photovoltaic (PV) system is described. The program, called PVC, was written in visual basic for windows and aimed as a tool for studying individual cell characteristics as well as PV system as a whole. This paper describes the mathematical models used in the program, an overview of the program and its application in analyzing a BP275 PV system. (author)

  4. Multilocus Sequence Typing Reveals Relevant Genetic Variation and Different Evolutionary Dynamics among Strains of Xanthomonas arboricola pv. juglandis

    Directory of Open Access Journals (Sweden)

    Marco Scortichini

    2010-11-01

    Full Text Available Forty-five Xanthomonas arboricola pv. juglandis (Xaj strains originating from Juglans regia cultivation in different countries were molecularly typed by means of MultiLocus Sequence Typing (MLST, using acnB, gapA, gyrB and rpoD gene fragments. A total of 2.5 kilobases was used to infer the phylogenetic relationship among the strains and possible recombination events. Haplotype diversity, linkage disequilibrium analysis, selection tests, gene flow estimates and codon adaptation index were also assessed. The dendrograms built by maximum likelihood with concatenated nucleotide and amino acid sequences revealed two major and two minor phylotypes. The same haplotype was found in strains originating from different continents, and different haplotypes were found in strains isolated in the same year from the same location. A recombination breakpoint was detected within the rpoD gene fragment. At the pathovar level, the Xaj populations studied here are clonal and under neutral selection. However, four Xaj strains isolated from walnut fruits with apical necrosis are under diversifying selection, suggesting a possible new adaptation. Gene flow estimates do not support the hypothesis of geographic isolation of the strains, even though the genetic diversity between the strains increases as the geographic distance between them increases. A triplet deletion, causing the absence of valine, was found in the rpoD fragment of all 45 Xaj strains when compared with X. axonopodis pv. citri strain 306. The codon adaptation index was high in all four genes studied, indicating a relevant metabolic activity.

  5. Data monitoring system for PV solar generators

    International Nuclear Information System (INIS)

    The two 1.5 kWp photovoltaic (PV) solar generators are installed and the new PC data monitoring system is developed by applying EC standards for European Solar Test Installation (ESTI). The schematic system diagram of PV generator is presented. The recording parameters for analytical and global monitoring are discussed. The meteorological data from ESTI sensors, temperature sensor and electrical data from inverter and calibrated shunt are stored via analog digital converters (ADC) on a hard disk of data storage PC. Data Logger and Monitor software for automatic data acquisition, treatment and visual distance control of all output PV data from PV solar generator has been created

  6. Electrical PV array reconfiguration strategy for energy extraction improvement in grid-connected PV systems

    OpenAIRE

    Velasco Quesada, Guillermo; Guinjoan Gispert, Francisco; Piqué López, Robert; Román Lumbreras, Manuel; Alfonso, Conesa

    2009-01-01

    This paper applies a dynamical electrical array reconfiguration (EAR) strategy on the photovoltaic (PV) generator of a grid-connected PV system based on a plant-oriented configuration, in order to improve its energy production when the operating conditions of the solar panels are different. The EAR strategy is carried out by inserting a controllable switching matrix between the PV generator and the central inverter, which allows the electrical reconnection of the available PV modules. A...

  7. 40 CFR 180.1261 - Xanthomonas campestris pv. vesicatoria and Pseudomonas syringae pv. tomato specific Bacteriophages.

    Science.gov (United States)

    2010-07-01

    ... and Pseudomonas syringae pv. tomato specific Bacteriophages. 180.1261 Section 180.1261 Protection of.... vesicatoria and Pseudomonas syringae pv. tomato specific Bacteriophages. An exemption from the requirement of... syringae pv. tomato specific bacteriophages in or on pepper and tomato....

  8. Adiabatic Rearrangement of Hollow PV Towers

    Directory of Open Access Journals (Sweden)

    Eric A Hendricks

    2010-10-01

    Full Text Available Diabatic heating from deep moist convection in the hurricane eyewall produces a towering annular structure of elevated potential vorticity (PV. This structure has been referred to as a hollow PV tower. The sign reversal of the radial gradient of PV satisfies the Charney-Stern necessary condition for combined barotropic-baroclinic instability. For thin enough annular structures, small perturbations grow exponentially, extract energy from the mean flow, and lead to hollow tower breakdown, with significant vortex structural and intensity change. The three-dimensional adiabatic rearrangements of two prototypical hurricane-like hollow PV towers (one thick and one thin are examined in an idealized framework. For both hollow towers, dynamic instability causes air parcels with high PV to be mixed into the eye preferentially at lower levels, where unstable PV wave growth rates are the largest. Little or no mixing is found to occur at upper levels. The mixing at lower and middle levels is most rapid for the breakdown of the thin hollow tower, consistent with previous barotropic results. For both hollow towers, this advective rearrangement of PV affects the tropical cyclone structure and intensity in a number of ways. First, the minimum central pressure and maximum azimuthal mean velocity simultaneously decrease, consistent with previous barotropic results. Secondly, isosurfaces of absolute angular momentum preferentially shift inward at low levels, implying an adiabatic mechanism by which hurricane eyewall tilt can form. Thirdly, a PV bridge, similar to that previously found in full-physics hurricane simulations, develops as a result of mixing at the isentropic levels where unstable PV waves grow most rapidly. Finally, the balanced mass field resulting from the PV rearrangement is warmer in the eye between 900 and 700 hPa. The location of this warming is consistent with observed warm anomalies in the eye, indicating that in certain instances the hurricane

  9. PV GAP: benefits of standards and quality assurance for the PV industry

    International Nuclear Information System (INIS)

    The birth of the Global Approval Programme for Photovoltaics (PV GAP) to address the need for a quality assurance programme for PV components, installations, systems, after sales maintenance, and in electrification projects is reported, and the establishment of a globally accepted approval/certification programme, and the advantages of using the already established internationally accepted International Electrotechnical Commission Quality Assessment System for Electronic Components (IECQ) to administer the PV GAP approval process are discussed. Details are given of the approval process for testing laboratories, the benefits of reciprocity of testing laboratory results, the licensing of the PV quality mark and seal; and the structure of PV GAP

  10. The PV market - Past, present, and future

    International Nuclear Information System (INIS)

    This paper forecasts the photovoltaic (PV) market growth for the 1900's. Ten years of PV history are reviewed and used to establish market trends in terms of average selling price (ASP) and kilowatts shipped by market segment. The market is segmented into indoor consumer, stand-alone, and grid-connected applications. Indoor consumer presently represents a saturated market and is fairly predictable. The stand-alone market (i.e. not connected to the utility grid) is fairly stable and predictable. The utility PV market, however, is highly dependent on a number of market factors such as the cost of conventional energy, the cost of PV systems, utility acceptance of PV, and regulatory controls. Government and institutional regulations, environmental issues, OPEC and Middle East politics will have the greatest impact on the cost of conventional fuels. Private and federal investment in PV technology development could have a significant impact on the cost of PV systems. Forecasts are provided through the year 2000 for indoor consumer, stand-alone, and utility markets. PV has unique attributes which make it a desirable source of energy in specific applications. It is a renewable source of energy, non-polluting, very reliable, predictable, low maintenance, modular, and has a very low operating cost. The energy source (sunlight) is distributed around the globe. Its limitations are high initial cost, no inherent energy storage, and low energy density

  11. Distributed PV Adoption - Sensitivity to Market Factors

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Sigrin, Ben

    2016-02-01

    NREL staff used the dSolar (distributed solar) model to forecast the adoption of distributed, behind-the-meter PV through the year 2050 for 9 different scenarios. The scenarios varied in their assumptions about a carbon tax, the cost of PV systems in the future, and what credit would be given for excess generation once current net metering policies expire.

  12. Global PV markets and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Wolfsegger, Cristoph [European Photolvoltaic Industry Association (EPIA), Brussels, Belgium (Belgium)

    2007-06-15

    This presentation mainly talks about the global importance of the PV industry, not only in the environmental sphere but also in the economic sphere. It is firstly given the major information of the European Photovoltaic Industry Association (EPIA), where there can be found the lists of those full member countries that work as: components manufacturers, consulting, and associate members. Then, it is given a briefly explanation about the Alliance for Rural Electrification (ARE), and the reasons why the -PV systems- are almost the panacea to both the energy and the environmental issue. In addition, it is given the most relevant information about how to implement this system in those regions that have not yet implemented it. Besides, there are explained some of the benefits that this system has. It is shortly explained how this system is working in German and it is also shown a comparison chart about the photovoltaic feed-in tariffs. There are shown some graphics and charts having information related to the global markets and the global installations of PV systems and other issues related to them. [Spanish] Esta presentacion habla principalmente acerca de la importancia que hoy en dia tiene la industria fotovoltaica alrededor del mundo, esto no solo ocurre en el ambito ambiental sino tambien en el economico. En la primer parte se muestra la informacion mas importante acerca de la Asociacion Europea de la Industria Fotovoltaica (EPIA por sus siglas en ingles), en donde se encuentran las listas de los paises que son miembros permanentes trabajando como: fabricantes de componentes, asesores y miembros asociados. Enseguida, se da, de manera escueta, una explicacion acerca de la ARE, asi como las razones por las que los sistemas fotovoltaicos son casi la panacea tanto para los problemas ambientales como para los energeticos. Ademas, se explica la informacion mas relevante acerca de como implementar este sistema en aquellas partes del mundo que todavia no lo han realizado

  13. Learning in PV trends and future prospects

    International Nuclear Information System (INIS)

    For large scale application of PV cost reduction is essential. It is shown in this study that the price evolution is on track and even accelerating the last 15 years. Using an experience curve approach a learning rate of little over 20% was found consistent with other studies. As data were collected for small rooftop grid connected systems, it could be shown that this learning rate is not only found for modules, but also for BOS (all costs apart from the modules) in Germany as well as in the Netherlands. Projections of the future price of PV systems show that a learning rate of at least 20% is needed to make introduction of PV affordable. It is very effective to invest in learning, thus increasing the learning rate, as well as developing market segments were the value of PV is higher, such as residential PV systems in southern Europe

  14. Learning in PV trends and future prospects

    International Nuclear Information System (INIS)

    For large scale application of PV cost reduction is essential. It is shown in this study that the price evolution is on track and even accelerating the last 15 years. Using an experience curve approach a learning rate of little over 20% was found consistent with other studies. As data were collected for small roof-top grid connected systems, it could be shown that this learning rate is not only found for modules, but also for BOS in Germany as well as in the Netherlands. Projections of the future price of PV systems show that a learning rate of at least 20% is needed to make introduction of PV affordable. It is very effective to invest in learning, thus increasing the learning rate, as well as developing market segments were the value of PV is higher, such as residential PV systems in southern Europe. (authors)

  15. Power of design - the future of building-integrated PV

    Energy Technology Data Exchange (ETDEWEB)

    Abbate, Cinzia [ENEL, Rome (Italy). Officine di Architettura

    2001-04-01

    This paper discusses strategies to make building integrated photovoltaic (PV) systems more acceptable and to allow PV material to compete with conventional construction material. The history of developments in building integration and difficulties encountered by architects wishing to use PV products are explored, and the Dutch Amersfoot project in Utrecht involving a new suburb of 501 house covered with PV panels is described. Questions raised regarding architectural integration of PV systems, and PV systems and the construction market are discussed. The Italian PV programme, financial and political constraints, and the positioning of PV on existing structures are reported.

  16. Power of design - the future of building-integrated PV

    International Nuclear Information System (INIS)

    This paper discusses strategies to make building integrated photovoltaic (PV) systems more acceptable and to allow PV material to compete with conventional construction material. The history of developments in building integration and difficulties encountered by architects wishing to use PV products are explored, and the Dutch Amersfoot project in Utrecht involving a new suburb of 501 house covered with PV panels is described. Questions raised regarding architectural integration of PV systems, and PV systems and the construction market are discussed. The Italian PV programme, financial and political constraints, and the positioning of PV on existing structures are reported

  17. The market for photovoltaic (PV) technology

    International Nuclear Information System (INIS)

    This paper describes a study that was intended to provide the Electric Power Research Institute (EPRI) with a market analysis for photovoltaic (PV) technologies under development by EPRI and others. The analysis was to focus on markets and factors leading to significant incremental growth for PV demand, large enough to support more efficient scale PV manufacturing capacity. EPRI anticipates that PV ultimately could provide grid-connected power, however, the 1995--2010 market dynamics are uncertain. The specific objectives of this study, therefore, were to: determine what major future domestic US markets for PV technologies will emerge and provide enough volume to support significant improvements in manufacturing costs through manufacturing economies of scale; provide insight on what is needed to gain acceptance of PV technologies for electric power generation in those major markets; provide insight on when investments in demonstration and manufacturing facilities should be made and what is needed to be successful in each element of the business that these markets could support (e.g., technology development, manufacturing, sales, installation, and service); and provide key insights on the requirements for commercial success of PV in the utility sector

  18. Multifunctional a-Si PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Peippo, K.; Lund, P.; Vartiainen, E. [Helsinki Univ. of Technology, Otaniemi (Finland). Advanced Energy Systems

    1998-10-01

    The optimal use of the various forms of solar energy (passive, active, daylighting, photovoltaics) in buildings calls for an optimal integration of the technologies. As energy conservation potential in space heating may soon be exhausted, electricity efficiency and on-site generation will play an increasing role in energy-conscious building design. There, dispersed PV systems integrated into buildings show a significant market potential, due to a number of benefits: no extra land area is required, PV-array may replace conventional cladding materials and become a building element. Moreover, the produced PV-electricity is more valuable for the building owner than for an electric utility

  19. Optimal design of PV and HP system

    DEFF Research Database (Denmark)

    Nepper-Rasmussen, Bjarke Christian; Rasmussen, Theis Bo

    2015-01-01

    Methods of utilizing residential produced photovoltaic (PV) power by converting to thermal energy through heat pumps (HP) are present in literature, where thermal energy is dispersed as either heat or hot water at the instant moment of PV production. In this paper an alternative solution is...... described, where the thermal energy is stored in a buffer tank (BT) capable of dispersing heat to either the heating system of a house or a hot water tank, for later use. The thermal storage solution including a BT can increase the self-consumption of residentially produced PV power and thereby shift...

  20. PV-hybrid and mini-grid

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Within the 5th European PV-hybrid and mini-grid conference 29th and 30th April, 2010 in Tarragona (Spain) the following lectures were held: (1) Overview of IEA PVPS Task 11 PV-hybrid systems within mini grids; (2) Photovoltaic revolution for deployment in developing countries; (3) Legal and financial conditions for the sustainable operation of mini-grids; (4) EU instruments to promote renewable energies in developing countries; (5) PV hybridization of diesel electricity generators: Conditions of profitability and examples in differential power and storage size ranges; (6) Education suit of designing PV hybrid systems; (7) Sustainable renewable energy projects for intelligent rural electrification in Laos, Cambodia and Vietnam; (8) Techno-economic feasibility of energy supply of remote villages in Palestine by PV systems, diesel generators and electric grid (Case studies: Emnazeil and Atouf villages); (9) Technical, economical and sustainability considerations of a solar PV mini grid as a tool for rural electrification in Uganda; (10) Can we rate inverters for rural electrification on the basis of energy efficiency?; (11) Test procedures for MPPT charge controllers characterization; (12) Energy storage for mini-grid stabilization; (13) Redox flow batteries - Already an alternative storage solution for hybrid PV mini-grids?; (14) Control methods for PV hybrid mini-grids; (15) Partial AC-coupling in mini-grids; (15) Normative issues of small wind turbines in PV hybrid systems; (16) Communication solutions for PV hybrid systems; (17) Towards flexible control and communication of mini-grids; (18) PV/methanol fuel cell hybrid system for powering a highway security variable message board; (19) Polygeneration smartgrids: A solution for the supply of electricity, potable water and hydrogen as fuel for transportation in remote Areas; (20) Implementation of the Bronsbergen micro grid using FACDS; (21) A revisited approach for the design of PV wind hybrid systems; (22

  1. PV: Bonus--Developing a U.S. market of PV in buildings

    International Nuclear Information System (INIS)

    The use of photovoltaic (PV) systems in and on buildings is seen as a key market for the PV industry. The buildings market is challenging, but it provides a large potential for increased US production of ''high-value'' PV technology that will benefit electric utilities and building owners. To assist the PV industry in developing products for this market, the US Department of Energy began a new initiative called ''Building Opportunities in the US for Photovoltaics'' (PV:BONUS). The responses cover nearly all of the PV-buildings product options envisioned, with multiple responses on topics such as architectural glazings and roofing systems. The paper describes the types of products that will be pursued by the teams selected. Additional supporting activities are described that will further encourage the development of a sustainable infrastructure

  2. Variation suggestive of horizontal gene transfer at a lipopolysaccharide (lps biosynthetic locus in Xanthomonas oryzae pv. oryzae, the bacterial leaf blight pathogen of rice

    Directory of Open Access Journals (Sweden)

    Sonti Ramesh V

    2004-10-01

    Full Text Available Abstract Background In animal pathogenic bacteria, horizontal gene transfer events (HGT have been frequently observed in genomic regions that encode functions involved in biosynthesis of the outer membrane located lipopolysaccharide (LPS. As a result, different strains of the same pathogen can have substantially different lps biosynthetic gene clusters. Since LPS is highly antigenic, the variation at lps loci is attributed to be of advantage in evading the host immune system. Although LPS has been suggested as a potentiator of plant defense responses, interstrain variation at lps biosynthetic gene clusters has not been reported for any plant pathogenic bacterium. Results We report here the complete sequence of a 12.2 kb virulence locus of Xanthomonas oryzae pv. oryzae (Xoo encoding six genes whose products are homologous to functions involved in LPS biosynthesis and transport. All six open reading frames (ORFs have atypical G+C content and altered codon usage, which are the hallmarks of genomic islands that are acquired by horizontal gene transfer. The lps locus is flanked by highly conserved genes, metB and etfA, respectively encoding cystathionine gamma lyase and electron transport flavoprotein. Interestingly, two different sets of lps genes are present at this locus in the plant pathogens, Xanthomonas campestris pv. campestris (Xcc and Xanthomonas axonopodis pv. citri (Xac. The genomic island is present in a number of Xoo strains from India and other Asian countries but is not present in two strains, one from India (BXO8 and another from Nepal (Nepal624 as well as the closely related rice pathogen, Xanthomonas oryzae pv. oryzicola (Xoor. TAIL-PCR analysis indicates that sequences related to Xac are present at the lps locus in both BXO8 and Nepal624. The Xoor strain has a hybrid lps gene cluster, with sequences at the metB and etfA ends, being most closely related to sequences from Xac and the tomato pathogen, Pseudomonas syringae pv. tomato

  3. Evaluation of the Antimicrobial Activity of Three Medicinal Plants of South India

    Directory of Open Access Journals (Sweden)

    Jamuna, B. A.

    2011-01-01

    Full Text Available The present study was carried out to evaluate the antimicrobial activity of the crude methanolic extracts of Memecylon malabaricum Clarke. (leaves, Cochlospermum religiosum Linn. (leaves and flowers and Andrographis serpyllifolia Vahl. (leaves using the standard disc diffusion assay against eight strains of bacterial species, viz., Staphylococcus aureus, Salmonella typhi, Enterobacter aerogenes, Pseudomonas aeruginosa, Xanthomonas oryzae pv. oryzae, Xanthomonas axonopodis pv. malvacearum, Bacillus cereus and Micrococcus sp. The extracts of the plants at a concentration of 1.25 mg/disc showed minimum to moderate activity against both Gram positive and Gram negative bacteria indicating a broad spectrum activity. A preliminary phytochemical screening was conducted on the selected plant extracts using standard qualitative procedures that revealed the presence of several secondary metabolites. The extracts failed to show antioxidant activity by reducing power assay. The result indicates the potential usefulness of these plants especially Memecylon malabaricum and Cochlospermum religiosum, in treating microbial infections in humans and plants and justifies the need for further investigations and characterization of the bioactive compounds present in the methanolic extracts of the plants.

  4. Possibility of recycling silicon PV modules

    International Nuclear Information System (INIS)

    A method of economically recovering silicon wafers from x-Si PV modules is presented. Since the wafer cost is estimated at about half the total material cost of a silicon PV module, there may be economic benefits from recycling. In addition, recycling silicon PV modules allows reclamation of the glass substrate and prevents disposal of potentially hazardous materials such as silver and lead from the wafer contact and interconnect systems. The major problem for recycling silicon Wafers from end-of-life devices has been cleanly separating the wafers from the EVA polymer encapsulating material. This paper describes the cost effective recycling of functioning x-Si PV cells after thermal decomposition of EVA in an inert gas atmosphere. Process costs are estimated at US $0.20 /per 10 cm x 10 cm recovered cell

  5. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case of...... these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were...... suggested to be used in commercial PV inverters for the measurement of leakage and fault ground currents. The German VDE0126–1–1 standard gives the limit for fault and leakage ground currents and all grid connected PV inverters have to comply with these limits and disconnect from the grid in case of a fault....

  6. Distributed PV Adoption in Maine Through 2021

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Sigrin, Ben

    2015-11-06

    NREL has used its dSolar (distributed solar) model to generate low-medium-high estimates of distributed PV adoption in Maine through 2021. This presentation gives a high-level overview of the model and modeling results.

  7. PV Module Reliability Research (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2013-06-01

    This National Center for Photovoltaics sheet describes the capabilities of its PV module reliability research. The scope and core competencies and capabilities are discussed and recent publications are listed.

  8. The potential of solar PV in Ontario

    International Nuclear Information System (INIS)

    Canada has lagged behind other industrialized nations in the growth of solar energy markets. Currently, over 78 per cent of the global market for solar energy is for grid-connected applications where power is fed into the electrical distribution network. Less than 3.5 per cent of the Canadian solar market is grid-connected. This report investigated the potential size of the photovoltaic (PV) market in Ontario given adequate support from both governments and utilities. The forecast was based on sustainable growth levels that the solar industry as a whole might maintain over an extended period of time. It was suggested that it is technically feasible to install over 3000 MW of PV in single, detached homes in the province, which could generate over 3200 GWh each year. If the right policy conditions were put in place, the technical potential for PV on all buildings in Ontario is over 14,000 MW by 2025, which would generate over 13,000 GWh annually. Support mechanisms such as the Advanced Renewable Tariff (ART) or Standard Offer Contracts (SOC) will enable the PV industry to build capacity. Future markets for PV include new homes, commercial buildings and the existing housing stock. With a properly designed system, it is forecasted that the deployment of PV by 2025 could result in the involvement of 400,000 homes with over 1200 MW of installed capacity and over 290 MW installed annually by 2025. Recommendations to Ontario Power Authority's (OPA) report supply mix report focused on the use of SOCs as the appropriate support mechanism to start building solar capacity in Ontario, as projections using SOCs would see Ontario following the growth patterns of other nations. It was concluded that the OPA report does not acknowledge the current growth rates of PV globally, nor does it fully consider the potential of PV in Ontario. 9 refs., 8 figs

  9. PV array simulator development and validation

    International Nuclear Information System (INIS)

    The ability to harvest all available energy from a photovoltaic (PV) array is essential if new system developments are to meet levelized cost of energy targets and achieve grid parity with conventional centralized utility power. Therefore, exercising maximum power point tracking (MPPT) algorithms, dynamic irradiance condition operation and startup and shutdown routines and evaluating inverter performance with various PV module fill-factor characteristics must be performed with a repeatable, reliable PV source. Sandia National Laboratories is collaborating with Ametek Programmable Power to develop and demonstrate a multi-port TerraSAS PV array simulator. The simulator will replicate challenging PV module profiles, enabling the evaluation of inverter performance through analyses of the parameters listed above. Energy harvest algorithms have traditionally implemented methods that successfully utilize available energy. However, the quantification of energy capture has always been difficult to conduct, specifically when characterizing the inverter performance under non-reproducible dynamic irradiance conditions. Theoretical models of the MPPT algorithms can simulate capture effectiveness, but full validation requires a DC source with representative field effects. The DC source being developed by Ametek and validated by Sandia is a fully integrated system that can simulate an IV curve from the Solar Advisor Model (SAM) module data base. The PV simulator allows the user to change the fill factor by programming the maximum power point voltage and current parameters and the open circuit voltage and short circuit current. The integrated PV simulator can incorporate captured irradiance and module temperature data files for playback, and scripted profiles can be generated to validate new emerging hardware embedded with existing and evolving MPPT algorithms. Since the simulator has multiple independent outputs, it also has the flexibility to evaluate an inverter with multiple

  10. Building PV markets: customers and prices

    International Nuclear Information System (INIS)

    What makes market deployment strategies for PV successful? A group of specialists (from IEA Task 7) has been looking at the progress made so far. Here, in the first of two articles based on their report, the author presents some of their findings, including benefits and barriers for defined groups of customers; how customers for PV systems are identified, and what they are willing to pay. It also looks at current prices in different countries, and their possible trends. (Author)

  11. Addressing firefighter safety around solar PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Harris, B. [Sustainable Energy Technologies, Calgary, AB (Canada)

    2010-11-15

    The article discussed new considerations for installing photovoltaic (PV) systems that address the needs of fire service personnel. The presence of a PV system presents a multitude of dangers for firefighters, including electrical shock, the inhalation of toxic gases from being unable to cut a hole through the roof, falling debris and flying glass, and dead loading on a compromised structure and tripping on conduits. Mapping systems should be modified so that buildings with PV systems are identified for first responders, including firefighters who should learn that solar modules present an electrical hazard during the day but not at night; covering PV modules with foam or salvage covers may not shut the system down to a safe level; it takes a few moments for the power in PV modules to reduce to zero; and PV modules or conduit should never be cut, broke, chopped, or walked upon. The California Department of Forestry and Fire Protection recommends creating pathways and allowing easier access to the roof by setting the modules back from roof edges, creating a structurally sound pathway for firefighters to walk on and space to cut ventilation holes. However, the setback rule makes the economics of solar installation less viable for residential applications. The technological innovations aimed at addressing system safety all focus on limiting firefighter contact with live electrical components to within the extra-low-voltage (ELV) band. Some of the inverters on the market that support ELV system architecture were described. 1 fig.

  12. Towards mature design of PV powered products

    Energy Technology Data Exchange (ETDEWEB)

    Kan, S.Y.; Beers, S. van; Brezet, H. [Delft University of Technology, Faculty of Industrial Design Engineering, Section Design for Sustainability Program, Delft (Netherlands)

    2004-07-01

    The appearance and the actual convenience of photovoltaic (PV) powered products is often not properly considered in sustainable product design. We undertook an endeavour to identify and chart the main factors that need to be improved in order to reduce those neglects and to stimulate a broader use of PV cells in products. Moreover this paper will stir up the discussion on mature design quality of sustainable products. The word 'mature' can for instance mean timeless design. Some solutions and synergetic proper novel technologies are proposed for achieving a sound integration of PV cells into products. An introduction of mature design by optimizing ergonomical aspects, appearance and product - user context relevance is given. In particular the emphasis will be on good matching of the overall design with the PV cell characteristics. The uses of curved coloured PV surfaces will be highlighted. Although the appearance of PV powered products obviously contributes towards the diffusion of such products, it still remains a point of discussion what kind of appearance is decisive in this process. (orig.)

  13. PV Obelisk - Information system with photovoltaics

    International Nuclear Information System (INIS)

    This final report for the Swiss Federal Office of Energy (SFOE) describes the development of an information system powered by a photovoltaic (PV) array. As an innovative approach, the 'PV-Obelisk' project is the combination of PV with a multi-functional pillar made of natural stone in an aesthetic way. The PV modules serve both as a power supply and as a design element. Two initial prototypes led the way to a third, optimised consumer configuration that was planned to guarantee maximum user frequency. Test operation in front of the 'Heidiland' motor way restaurant confirmed the market analyses made and delivered the expected results. The product, whose three LCD displays are updated via a mobile telephony-based text-message system, proved its technical reliability and showed a high user frequency. Because of the high overall energy consumption, PV power can only partially contribute to the energy supply needed. Various compromises in the technical and aesthetic areas are discussed that were made for the sake of product acceptance in the market. The range of application areas for such a 'PV Obelisk' are discussed and the need for early co-ordination with urban planners is stressed

  14. NCBI nr-aa BLAST: CBRC-XTRO-01-0625 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-0625 ref|NP_642734.1| integral membrane protein [Xanthomonas axonopodi...s pv. citri str. 306] gb|AAM37270.1| integral membrane protein [Xanthomonas axonopodis pv. citri str. 306] NP_642734.1 1e-62 27% ...

  15. Assessing the PV business opportunities in Greece

    International Nuclear Information System (INIS)

    Highlights: • An approach of qualitative judgments for the PV opportunities through the assessing of the licenses’ value in Greece. • It can be supplied in other countries by applying different weights to the criteria. • It can be used by everyone in order to find a suitable PV investment without the need of experts in the field. - Abstract: Greece, as a member of the European Union (EU), has undertaken the obligation to meet the expected goals for the penetration of Renewable Energy Sources (RES) in the national energy balance in compliance with “20–20–20” goals (20% of the Gross Energy Consumption and 40% of the Gross Electricity Consumption should be covered by RES). Although the development of RES, and particularly of Photovoltaic (PV), in Greece during the last years has presented a satisfactory growth, the country is still far away from the above goals. The main reason for this delay is that – except the financial crisis – many licenses are inactive and waiting funding in order to be utilized. Additionally, the latest law (L.4152/2013) has forbidden the interconnection of new PV power Plants to the grid until the end of 2013. The above fact determines the significance of the existing PV Licenses in achieving the national goals. The aim of this paper is to present an integrated approach of qualitative judgments for the PV business opportunities through the assessing of the licenses’ value in Greece. The approach, which is based on a Multi Criteria Decision Making (MCDM) theory of quantifying multiple qualitative judgments, takes into account the real factors which can affect the expected production and cost of the PV installation and therefore the RoI (Return of Investment)

  16. Optimization of PV-based energy production by dynamic PV-panel/inverter configuration

    DEFF Research Database (Denmark)

    Paasch, Kasper; Nymand, Morten; Haase, Frerk

    This paper investigates the possible increase in annual energy production of a PV system with more than one MPPT (maximum power point tracker) input channels under Nordic illumination conditions, in case a concept of dynamic switching of the PV panels is used at the inputs of the inverters....

  17. PV/T slates - Laboratory measurements; PV/T-Schiefer. Labormessungen

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report deals with an experimental outdoor set-up and reviews in-situ measurements made on a prototype of a ventilated PV-tile system (PV/T-Slates). The report describes the configuration and construction of the experimental PV-tiled roof and the measurement system used to measure its electrical and thermal performance. The results of the measurements made are presented in detail in graphical form. The influence of various factors such as air-slit width and mounting angle are discussed.

  18. Prospects for PV: a learning curve analysis

    International Nuclear Information System (INIS)

    This article gives an overview of the current state-of-the-art of photovoltaic electricity technology, and addresses its potential for cost reductions over the first few decades of the 21st century. Current PV production cost ranges are presented, both in terms of capacity installation and electricity generation, of single crystalline silicon, multi-crystalline silicon, amorphous silicon and other thin film technologies. Possible decreases of these costs are assessed, as expected according to the learning-curve methodology. We also estimate how much PV could gain if external costs (due to environmental and health damage) of energy were internalised, for example by an energy tax. Our conclusions are that, (1) mainly due its high costs, PV electricity is unlikely to play a major role in global energy supply and carbon emissions abatement before 2020, (2) extrapolating learning curves observed in the past, one can expect its costs to decrease significantly over the coming years, so that a considerable PV electricity share world-wide could materialise after 2020, (3) niche-market applications, e.g. using stand-alone systems in remote areas, are crucial for continuing 'the ride along the learning curve', (4) damage costs of conventional (fossil) power sources are considerable, and their internalisation would improve the competitiveness of PV, although probably not enough to close the current cost gap. (author)

  19. Latin America as new PV market opportunity

    International Nuclear Information System (INIS)

    It is important to recognize solar energy as an international and strategic opportunity for the European market to expand. The objective of this paper is to apply the methodology created during the PV Parity project for analyzing PV Competitiveness in the emerging residential PV market in Brazil, using information from the State of Rio de Janeiro. The dynamic competitiveness analysis was performed considering the price with and without taxes in order to assess the year when PV will reach grid parity in Rio de Janeiro and how the taxes impact on the results. Results are divided into 3 scenarios: Optimistic, Conservative, and Conservative Moderate. The LCOE of residential systems will likely become competitive with the residential electricity tariffs between 2020 and 2030, assuming the residential tariffs in Rio de Janeiro. This is an indicator that PV energy business opportunities are increasing in Brazil and, with the adequate policy support, its market competitiveness could be improved. We are also looking in other markets of Latin America. (full text)

  20. PV performance modeling workshop summary report.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua S.; Tasca, Coryne Adelle (SRA International, Inc., Fairfax, VA); Cameron, Christopher P.

    2011-05-01

    During the development of a solar photovoltaic (PV) energy project, predicting expected energy production from a system is a key part of understanding system value. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, annual energy yield (kWh/kWp) will vary among module technologies because of differences in response to low-light levels and temperature. A number of PV system performance models have been developed and are in use, but little has been published on validation of these models or the accuracy and uncertainty of their output. With support from the U.S. Department of Energy's Solar Energy Technologies Program, Sandia National Laboratories organized a PV Performance Modeling Workshop in Albuquerque, New Mexico, September 22-23, 2010. The workshop was intended to address the current state of PV system models, develop a path forward for establishing best practices on PV system performance modeling, and set the stage for standardization of testing and validation procedures for models and input parameters. This report summarizes discussions and presentations from the workshop, as well as examines opportunities for collaborative efforts to develop objective comparisons between models and across sites and applications.

  1. POWERED LED LIGHTING SUPPLIED FROM PV CELLS

    Directory of Open Access Journals (Sweden)

    Tirshu M.

    2011-12-01

    Full Text Available The paper deals with practical realization of efficient lighting system based on LED’s of 80W total power mounted on corridor ceiling total length of which is 120m and substitutes existing traditional lighting system consisting of 29 lighting blocks with 4 fluorescent lamps each of them and summary power 2088W. Realized lighting system is supplied from two photovoltaic panels of power 170W. Generated energy by PV cells is accumulated in two accumulators of 75Ah capacity and from battery by means of specialized convertor is applied to lighting system. Additionally, paper present data measured by digital weather station (solar radiation and UV index, which is mounted near of PV cells and comparative analyze of solar energy with real energy generated by PV cells is done. Measured parameters by digital weather station are stored by computer in on-line mode.

  2. Terawatt Challenge for Thin-Film PV

    Energy Technology Data Exchange (ETDEWEB)

    Zweibel, K.

    2005-08-01

    The evolution of PV into one of the world's largest industries is not going to happen without major unforeseen problems. However, this study attempts to address the obvious ones, so that we can put aside the mythology of PV (for example, that it is only ''boutique power'' or that one must pave the world with it to be useful) and get on with changing the world's energy infrastructure. With the years of rapid market growth now under way in PV, the author is sure this will not be the last effort to understand the real potential and pitfalls of meeting the Challenge.

  3. PV production forecast in La Reunion Island

    Science.gov (United States)

    Dubus, L.; Leboucher, V.; Garo, M.

    2010-09-01

    Photovoltaic power production is developing quickly in La Reunion (Indian Ocean). In order to integrate this fluctuating energy source into the network, reliable production forecasts are necessary from real time to day+3. Weather forecasts from standard models are in general inadequate, in particular due to too coarse resolution in this complex orography area. In this study, we use observations (Météo-France) and reanalysis (ERAinterim) fields to evaluate the potential predictability of PV production, for individual solar power plants and from the island aggregated point of view. This in particular allows to select the best weather predictors for PV production. The forecast quality of the selected fields was then established, in order to use only the interesting ones. Finally, NWPs are used to estimate which part of PV production predictability is accessible with state of the art weather forecasting models. This leads to requirements on temporal and spatial resolution of NWP to improve the forecast quality.

  4. PV panel model based on datasheet values

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Rodriguez, Pedro

    This work presents the construction of a model for a PV panel using the single-diode five-parameters model, based exclusively on data-sheet parameters. The model takes into account the series and parallel (shunt) resistance of the panel. The equivalent circuit and the basic equations of the PV cell....../panel in Standard Test Conditions (STC) are shown, as well as the parameters extraction from the data-sheet values. The temperature dependence of the cell dark saturation current is expressed with an alternative formula, which gives better correlation with the datasheet values of the power temperature...... dependence. Based on these equations, a PV panel model, which is able to predict the panel behavior in different temperature and irradiance conditions, is built and tested....

  5. Real time PV manufacturing diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Kochergin, Vladimir [MicroXact Inc., Blacksburg, VA (United States); Crawford, Michael A. [MicroXact Inc., Blacksburg, VA (United States)

    2015-09-01

    The main obstacle Photovoltaic (PV) industry is facing at present is the higher cost of PV energy compared to that of fossil energy. While solar cell efficiencies continue to make incremental gains these improvements are so far insufficient to drive PV costs down to match that of fossil energy. Improved in-line diagnostics however, has the potential to significantly increase the productivity and reduce cost by improving the yield of the process. On this Phase I/Phase II SBIR project MicroXact developed and demonstrated at CIGS pilot manufacturing line a high-throughput in-line PV manufacturing diagnostic system, which was verified to provide fast and accurate data on the spatial uniformity of thickness, an composition of the thin films comprising the solar cell as the solar cell is processed reel-to-reel. In Phase II project MicroXact developed a stand-alone system prototype and demonstrated the following technical characteristics: 1) ability of real time defect/composition inconsistency detection over 60cm wide web at web speeds up to 3m/minute; 2) Better than 1mm spatial resolution on 60cm wide web; 3) an average better than 20nm spectral resolution resulting in more than sufficient sensitivity to composition imperfections (copper-rich and copper-poor regions were detected). The system was verified to be high vacuum compatible. Phase II results completely validated both technical and economic feasibility of the proposed concept. MicroXact’s solution is an enabling technique for in-line PV manufacturing diagnostics to increase the productivity of PV manufacturing lines and reduce the cost of solar energy, thus reducing the US dependency on foreign oil while simultaneously reducing emission of greenhouse gasses.

  6. Economic perspective of PV electricity in Oman

    International Nuclear Information System (INIS)

    Solar and wind energies are likely to play an important role in the future energy generation in Oman. This paper utilizes average daily global solar radiation and sunshine duration data of 25 locations in Oman to study the economic prospects of solar energy. The study considers a solar PV power plant of 5-MW at each of the 25 locations. The global solar radiation varies between slightly greater than 4 kWh/m2/day at Sur to about 6 kWh/m2/day at Marmul while the average value in the 25 locations is more than 5 kWh/m2/day. The results show that the renewable energy produced each year from the PV power plant varies between 9000 MWh at Marmul and 6200 MWh at Sur while the mean value is 7700 MWh of all the 25 locations. The capacity factor of PV plant varies between 20% and 14% and the cost of electricity varies between 210 US$/MWh and 304 US$/MWh for the best location to the least attractive location, respectively. The study has also found that the PV energy at the best location is competitive with diesel generation without including the externality costs of diesel. Renewable energy support policies that can be implemented in Oman are also discussed. -- Research highlights: → The global solar radiation values for 25 locations in Oman are obtained using satellite data that are corrected by data from ground stations. → The study considers a solar PV power plant of 5-MW to calculate the capacity factor (CF) and the cost of energy (COE) at each of the 25 locations. → The study has found that the CF of PV plant varies between 20% and 14% and the corresponding COE varies between 210 US$/MWh and 304 US$/MWh for the best location to the least attractive location, respectively. → The study has found that the PV energy at the best location is competitive with diesel generation without including the externality costs of diesel. → Since PV energy is not competitive with fossil fuel-based generation in most locations renewable energy support mechanisms have been reviewed.

  7. Seasonal energy storage - PV-hydrogen systems

    Energy Technology Data Exchange (ETDEWEB)

    Leppaenen, J. [Neste Oy/NAPS (Finland)

    1998-10-01

    PV systems are widely used in remote areas e.g. in telecommunication systems. Typically lead acid batteries are used as energy storage. In northern locations seasonal storage is needed, which however is too expensive and difficult to realise with batteries. Therefore, a PV- battery system with a diesel backup is sometimes used. The disadvantages of this kind of system for very remote applications are the need of maintenance and the need to supply the fuel. To overcome these problems, it has been suggested to use hydrogen technologies to make a closed loop autonomous energy storage system

  8. International PV QA Task Force's Proposed Comparative Rating System for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, J.; Kurtz, S.

    2014-10-01

    The International PV Quality Assurance Task Force is developing a rating system that provides comparative information about the relative durability of PV modules. Development of accelerated stress tests that can provide such comparative information is seen as a major step toward being able to predict PV module service life. This paper will provide details of the ongoing effort to determine the format of such an overall module rating system. The latest proposal is based on using three distinct climate zones as defined in IEC 60721-2-1 for two different mounting systems. Specific stresses beyond those used in the qualification tests are being developed for each of the selected climate zones.

  9. Design optimization of grid-connected PV inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    The DC/AC inverters are the key elements in grid-connected PV energy production systems. In this paper, new design optimization techniques focused on transformerless (very high efficiency) PV inverters are proposed. They have been developed based on an analysis of the deficiencies of the current......, state-of-the-art PV inverters design technology, which limits the amount of PV energy supplied into the electric grid. The influences of the electric grid regulations and standards and the PV array operational characteristics on the design of grid-connected PV inverters have also been considered. The...... simulation results verify that the proposed optimization techniques enable the maximization of the PV energy injected into the electric grid by the optimized PV installation....

  10. National survey report on PV power applications in Switzerland 2006

    International Nuclear Information System (INIS)

    This annual report was published by the Swiss Federal Office of Energy (SFOE) as part of the International Energy Agency's work on the exchange and dissemination of information on photovoltaic power systems (PVPS). The political situation in Switzerland with regard to the promotion of photovoltaics (PV) and new legislation in the energy area is discussed. The report provides information on installed PV power, costs and prices and the Swiss PV industry. Examples of PV applications are presented and data on the cumulative installed PV power in various application sectors is presented and discussed. Highlights, major projects and various demonstration and field-test programmes are dealt with, as are public budgets for market stimulation. Figures on the development, production and prices of PV cells and modules are presented. Swiss balance-of-system products are reviewed, as are PV-related services and the value of the Swiss PV business. A review of non-technical factors and new initiatives completes the report.

  11. Optimal Design of Modern Transformerless PV Inverter Topologies

    OpenAIRE

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The design optimization of H5, H6, neutral point clamped, active-neutral point clamped, and conergy-NPC transformerless photovoltaic (PV) inverters is presented in this paper. The components reliability in terms of the corresponding malfunctions, affecting the PV inverter maintenance cost during the operational lifetime period of the PV installation, is also considered in the optimization process. According to the results of the proposed design method, different optimal values of the PV inver...

  12. MPPT algorithm for voltage controlled PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco;

    2008-01-01

    This paper presents a novel concept for an MPPT that can be used in case of a voltage controlled grid connected PV inverters. In case of single-phase systems, the 100 Hz ripple in the AC power is also present on the DC side. Depending on the DC link capacitor, this power fluctuation can be used to...

  13. PV experience curves for the Netherlands

    International Nuclear Information System (INIS)

    Experience curves are one of several tools used by policy makers to take a look at market development. Numerous curves have been constructed for PV but none specific to the Netherlands. The objective of this report is to take a look at the price development of grid-connected PV systems in the Netherlands using the experience curve theory. After a literature and internet search and attempts to acquire information from PV companies information on 51% of the totally installed capacity was found. Curves for the period 1991-2001 were constructed based on system price, BOS (balance-of-system) price and inverter price. The progress ratio of the locally learning BOS was similar to the globally learning module market. This indicates that the pace of development of the Dutch PV market is similar to the globally followed pace. Improvement of the detail of the data might help to get a better idea of which BOS components have declined most. The similar progress ratio also shows the importance of investing both in module and system research as is the case in the Netherlands

  14. TRNSYS HYBRID wind diesel PV simulator

    Energy Technology Data Exchange (ETDEWEB)

    Quinlan, P.J.A.; Mitchell, J.W.; Klein, S.A.; Beckman, W.A.; Blair, N.J. [Univ. of Wisconsin, Madison, WI (United States)

    1996-12-31

    The Solar Energy Laboratory (SEL) has developed a wind diesel PV hybrid systems simulator, UW-HYBRID 1.0, an application of the TRNSYS 14.2 time-series simulation environment. An AC/DC bus links up to five diesels and wind turbine models, along with PV modules, a battery bank, and an AC/DC converter. Multiple units can be selected. PV system simulations include solar angle and peak power tracking options. Weather data are Typical Meteorological Year data, parametrically generated synthesized data, or external data files. PV performance simulations rely on long-standing SEL-developed algorithms. Loads data are read as scalable time series. Diesel simulations include estimated fuel-use and waste heat output, and are dispatched using a least-cost of fuel strategy. Wind system simulations include varying air density, wind shear and wake effects. Time step duration is user-selectable. UW-HYBRID 1.0 runs in Windows{reg_sign}, with TRNSED providing a customizable user interface. 12 refs., 6 figs.

  15. Final Technical Report: PV Fault Detection Tool.

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce Hardison [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The PV Fault Detection Tool project plans to demonstrate that the FDT can (a) detect catastrophic and degradation faults and (b) identify the type of fault. This will be accomplished by collecting fault signatures using different instruments and integrating this information to establish a logical controller for detecting, diagnosing and classifying each fault.

  16. PV-mooduli toodang suurfarmis / Teolan Tomson

    Index Scriptorium Estoniae

    Tomson, Teolan, 1932-

    2015-01-01

    Artiklis uuritakse PV-paneelide tootlikkuse langust nende vastastikuse varjutamise tõttu. Näidatakse, et Eesti oludes on soovitav kasutada paneelide madalaid kaldenurki ja suhtelist reavahet, mis ületab paneeli kõrguse pooleteistkordset väärtust

  17. Invisible photovoltaics - PV basics + 25 design examples

    NARCIS (Netherlands)

    Meekma, L.T.; Valdes Cano, N.A.; Zhindon Andrade, P.

    2015-01-01

    This "designers' manual" is made during the TIDO-course AR0531 Innovation and Sustainability This manual is intended for architects and designers. Its main objective is to address PV technology as a building material alternative for the architect to incorporate in his design repertoire.

  18. Commercialization of PV-powered pumping systems for use in utility PV service programs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project described in this report was a commercialization effort focused on cost-effective remote water pumping systems for use in utility-based photovoltaic (PV) service programs. The project combined a commercialization strategy tailored specifically for electric utilities with the development of a PV-powered pumping system that operates conventional ac pumps rather than relying on the more expensive and less reliable PV pumps on the market. By combining these two attributes, a project goal was established of creating sustained utility purchases of 250 PV-powered water pumping systems per year. The results of each of these tasks are presented in two parts contained in this Final Summary Report. The first part summarizes the results of the Photovoltaic Services Network (PSN) as a new business venture, while the second part summarizes the results of the Golden Photon system installations. Specifically, results and photographs from each of the system installations are presented in this latter part.

  19. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu;

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module...

  20. Remote and Centralized Monitoring of PV Power Plants

    DEFF Research Database (Denmark)

    Kopacz, Csaba; Spataru, Sergiu; Sera, Dezso;

    2014-01-01

    measurements from the inverters within each PV plant. The monitoring software stores the PV measurements in a data warehouse optimized for managing and data mining large amounts of data, from where it can be later visualized, analyzed and exported. By combining PV production measurements data with I-V curve...

  1. High Resolution PV Power Modeling for Distribution Circuit Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Norris, B. L.; Dise, J. H.

    2013-09-01

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  2. PV Obelisk - Information system with photovoltaics; PV-Obelisk Orientierungssystem mit Photovoltaik

    Energy Technology Data Exchange (ETDEWEB)

    Ruoss, D.; Rasmussen, J.

    2004-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) describes the development of an information system powered by a photovoltaic (PV) array. As an innovative approach, the 'PV-Obelisk' project is the combination of PV with a multi-functional pillar made of natural stone in an aesthetic way. The PV modules serve both as a power supply and as a design element. Two initial prototypes led the way to a third, optimised consumer configuration that was planned to guarantee maximum user frequency. Test operation in front of the 'Heidiland' motor way restaurant confirmed the market analyses made and delivered the expected results. The product, whose three LCD displays are updated via a mobile telephony-based text-message system, proved its technical reliability and showed a high user frequency. Because of the high overall energy consumption, PV power can only partially contribute to the energy supply needed. Various compromises in the technical and aesthetic areas are discussed that were made for the sake of product acceptance in the market. The range of application areas for such a 'PV Obelisk' are discussed and the need for early co-ordination with urban planners is stressed.

  3. Beauveria bassiana: endophytic colonization and plant disease control.

    Science.gov (United States)

    Ownley, Bonnie H; Griffin, Mary R; Klingeman, William E; Gwinn, Kimberly D; Moulton, J Kevin; Pereira, Roberto M

    2008-07-01

    Seed application of Beauveria bassiana 11-98 resulted in endophytic colonization of tomato and cotton seedlings and protection against plant pathogenic Rhizoctonia solani and Pythium myriotylum. Both pathogens cause damping off of seedlings and root rot of older plants. The degree of disease control achieved depended upon the population density of B. bassiana conidia on seed. Using standard plating techniques onto selective medium, endophytic 11-98 was recovered from surface-sterilized roots, stems, and leaves of tomato, cotton, and snap bean seedlings grown from seed treated with B. bassiana 11-98. As the rate of conidia applied to seed increased, the proportion of plant tissues from which B. bassiana 11-98 was recovered increased. For rapid detection of B. bassiana 11-98 in cotton tissues, we developed new ITS primers that produce a PCR product for B. bassiana 11-98, but not for cotton. In cotton samples containing DNA from B. bassiana11-98, the fungus was detected at DNA ratios of 1:1000; B. bassiana 11-98 was detected also in seedlings grown from seed treated with B. bassiana 11-98. Using SEM, hyphae of B. bassiana11-98 were observed penetrating epithelial cells of cotton and ramifying through palisade parenchyma and mesophyll leaf tissues. B. bassiana11-98 induced systemic resistance in cotton against Xanthomonas axonopodis pv. malvacearum (bacterial blight). In parasitism assays, hyphae of B. bassiana 11-98 were observed coiling around hyphae of Pythium myriotylum. PMID:18442830

  4. Host Range and Seed Transmission of Xanthomonas axonopodis pv.cyamopsidis in Guar%瓜尔豆细菌性疫病种子带菌检测及寄主范围测定

    Institute of Scientific and Technical Information of China (English)

    任毓忠; 杨江平; 李腾宇; 王磊; 刘林; 王华兵

    2015-01-01

    瓜尔豆细菌性疫病是新疆新发现的一种病害,本文对4份瓜尔豆种子根据症状分为无症状型(占总调查种子数36.55%)、中间型(占总调查种子数51.94%)和严重变色型(占总调查种子数11.51%)三类,不同类型种子的室内发芽率、带菌率和出苗率存在明显差异,严重变色型种子发芽率最低,为31.11%;中间型和无症状型种子的发芽率相对较高,分别为87.78%和63.33%;在室内培养基上进行种子带菌率检测,结果表明,严重变色型种子的带菌率最高,为51.11%,中间型和无症状型的带菌率为31.11%和24.44%.在水琼脂上严重变色型种子的出苗率为42.00%;无症状种子和中间型的出苗率分别为71.67%和90.00%.盆栽幼苗出苗和发病实验结果显示,无症状种子的出苗率为83.33%,而严重变色种子的出苗率仅为40.00%;不同类型种子的带菌率存在明显差异,无症状种子的带菌率为59.18%,而严重变色种子的带菌率为84.38%,远高山无症状种子的发病率;表明种子严重变色(或带菌率较高)都会严重影响种子的质量,继而造成种子发芽率和田间出苗率的降低.人工接种寄主范围测定结果显示,瓜尔豆细菌性疫病还可以感染、大豆(Glycine max)、豇豆(Vigna unguiculata)、绿豆(Vigna radiata)和芸豆(Phaseolus coccineus L.var.albonanus Baile)等豆科作物.

  5. Comparison of photovoltaic (PV) panel usage in different climates

    OpenAIRE

    Kayalar, Rasiha

    2013-01-01

    ABSTRACT: In this thesis, PV panel usages will be analyzed in variable climates. By the way, during the research several case studies selected from both hot and cold climates will be observed, researched and calculated in order to find the best design principles for PV panel designs. So, comparative design method is selected to compare cold climate PV panel designs with hot climate PV panel designs. According to the findings, before designing the PV panel to the roof or facade or to the site,...

  6. Voltage rise mitigation for solar PV integration at LV grids

    DEFF Research Database (Denmark)

    Yang, Guangya; Marra, Francesco; Juamperez Goñi, Miguel Angel;

    2015-01-01

    Solar energy from photovoltaic (PV) is among the fastest developing renewable energy systems worldwide. Driven by governmental subsidies and technological development, Europe has seen a fast expansion of solar PV in the last few years. Among the installed PV plants, most of them are situated...... at the distribution systems and bring various operational challenges such as power quality and power flow management. The paper discusses the modelling requirements for PV system integration studies, as well as the possible techniques for voltage rise mitigation at low voltage (LV) grids for increasing PV penetration...

  7. Technologies to Increase PV Hosting Capacity in Distribution Feeders: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Gotseff, Peter

    2016-08-01

    This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.

  8. Battery Energy Storage System for PV Output Power Leveling

    OpenAIRE

    Rajkiran Singh; Seyedfoad Taghizadeh; Nadia Mei Lin Tan; Jagadeesh Pasupuleti

    2014-01-01

    Fluctuating photovoltaic (PV) output power reduces the reliability in power system when there is a massive penetration of PV generators. Energy storage systems that are connected to the PV generators using bidirectional isolated dc-dc converter can be utilized for compensating the fluctuating PV power. This paper presents a grid connected energy storage system based on a 2 kW full-bridge bidirectional isolated dc-dc converter and a PWM converter for PV output power leveling. This paper propos...

  9. Prospects for PV generation and market in China

    International Nuclear Information System (INIS)

    Installation of PV power station in remote areas have benefited the local people solving a difficulty of no electricity. But the rural PV demonstration project is for assisting some poor residents without payback and completed for a society benefit. During the design of urban domestic architecture of the residential PV system integration with building, then the cost of PV will be acceptable comparing the cost of land and building. Especially while AC power is put into the market, the residential PV generation should be the more accessible

  10. PV_LIB Toolbox v. 1.3

    Energy Technology Data Exchange (ETDEWEB)

    2015-12-09

    PV_LIB comprises a library of Matlab? code for modeling photovoltaic (PV) systems. Included are functions to compute solar position and to estimate irradiance in the PV system’s plane of array, cell temperature, PV module electrical output, and conversion from DC to AC power. Also included are functions that aid in determining parameters for module performance models from module characterization testing. PV_LIB is open source code primarily intended for research and academic purposes. All algorithms are documented in openly available literature with the appropriate references included in comments within the code.

  11. Accelerating residential PV expansion: demand analysis for competitive electricity markets

    International Nuclear Information System (INIS)

    This article quantifies the potential market for grid-connected, residential photovoltaic (PV) electricity integrated into new homes built in the US. It complements an earlier supply-side analysis by the authors that demonstrates the potential to reduce PV module prices below $1.5/Wp by scaling up existing thin-film technology in 100 MWp/yr manufacturing facilities. The present article demonstrates that, at that price, PV modules may be cost effective in 125,000 new home installations per year (0.5 GWp/yr). While this market is large enough to support multiple scaled up thin-film PV factories, inefficient energy pricing and demand-side market failures will inhibit prospective PV consumers without strong public policy support. Net metering rules, already implemented in many states to encourage PV market launch, represent a crude but reasonable surrogate for efficient electricity pricing mechanisms that may ultimately emerge to internalize the externality benefits of PV. These public benefits include reduced air pollution damages (estimated costs of damage to human health from fossil fuel power plants are presented in Appendix A), deferral of transmission and distribution capital expenditures, reduced exposure to fossil fuel price risks, and increased electricity system reliability for end users. Thus, net metering for PV ought to be implemented as broadly as possible and sustained until efficient pricing is in place. Complementary PV 'buydowns' (e.g., a renewable portfolio standard with a specific PV requirement) are needed to jumpstart regional PV markets

  12. Plasmodium vivax Tryptophan Rich Antigen PvTRAg36.6 Interacts with PvETRAMP and PvTRAg56.6 Interacts with PvMSP7 during Erythrocytic Stages of the Parasite.

    Science.gov (United States)

    Tyagi, Kriti; Hossain, Mohammad Enayet; Thakur, Vandana; Aggarwal, Praveen; Malhotra, Pawan; Mohmmed, Asif; Sharma, Yagya Dutta

    2016-01-01

    Plasmodium vivax is most wide spread and a neglected malaria parasite. There is a lack of information on parasite biology of this species. Genome of this parasite encodes for the largest number of tryptophan-rich proteins belonging to 'Pv-fam-a' family and some of them are potential drug/vaccine targets but their functional role(s) largely remains unexplored. Using bacterial and yeast two hybrid systems, we have identified the interacting partners for two of the P. vivax tryptophan-rich antigens called PvTRAg36.6 and PvTRAg56.2. The PvTRAg36.6 interacts with early transcribed membrane protein (ETRAMP) of P.vivax. It is apically localized in merozoites but in early stages it is seen in parasite periphery suggesting its likely involvement in parasitophorous vacuole membrane (PVM) development or maintenance. On the other hand, PvTRAg56.2 interacts with P.vivax merozoite surface protein7 (PvMSP7) and is localized on merozoite surface. Co-localization of PvTRAg56.2 with PvMSP1 and its molecular interaction with PvMSP7 probably suggest that, PvTRAg56.2 is part of MSP-complex, and might assist or stabilize the protein complex at the merozoite surface. In conclusion, the PvTRAg proteins have different sub cellular localizations and specific associated functions during intra-erythrocytic developmental cycle. PMID:26954579

  13. Impact of Rooftop Solar PV on Residential Distribution Network

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna;

    Increased environmental awareness in recent years has encouraged rapid growth of renewable energy sources especially solar PV and wind. Among them, small scale solar PV has been gaining more momentum especially at residential level. Even today moderate penetration of grid tied rooftop solar PV has...... become reality in many countries. In spite of various benefits, higher penetration of rooftop PVs might come up with number of detrimental effects, with power quality and overcurrent protection being the major ones. Therefore, it is reasonable to quantify both drawback and benefits of rooftop PV...... LV feeder provided with small scale rooftop PV. Voltage deviation index (VDI) and power loss index (PLI) has been used to quantify the impacts of PV. Furthermore, overvoltage has been taken as an operational constraint to determine maximum penetration level of PV. The analysis has been performed...

  14. Optimal Design of Modern Transformerless PV Inverter Topologies

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The design optimization of H5, H6, neutral point clamped, active-neutral point clamped, and conergy-NPC transformerless photovoltaic (PV) inverters is presented in this paper. The components reliability in terms of the corresponding malfunctions, affecting the PV inverter maintenance cost during......, neutral point clamped, active-neutral point clamped and conergy-NPC PV inverters designed using the proposed optimization process feature lower levelized cost of generated electricity and lifetime cost, longer mean time between failures and inject more PV-generated energy into the electric grid than their...... the operational lifetime period of the PV installation, is also considered in the optimization process. According to the results of the proposed design method, different optimal values of the PV inverter design variables are derived for each PV inverter topology and installation site. The H5, H6...

  15. Financial sustainability of PV implementation in Swaziland

    International Nuclear Information System (INIS)

    During the past 10 years, more than 700 Solar Home Systems have been implemented by this project in Swaziland, southern Africa. The implementation process started with household energy surveys, the results of which showing significant energy needs for cooking, lighting and basic communication applications (i.e. radio/TV), particularly in rural areas. An implementation project of Solar Home Systems was set up to start rural electrification with solar PV and focused on lighting and small electrical demands. The national government, whose own resources were limited, supported the project as an important step towards addressing the country's range of energy needs. Together with a local company, Swazitronix, a joint venture was established to facilitate the implementation project. With a project loan from the Dutch social bank, the Triodosbank, standard Solar Home Systems were sold, assembled, installed and serviced. Customers paid the full cost of their PV systems and services. Awareness and education issues also formed key aspects of the project. During a later project phase, credit financing instruments were introduced providing a final element of experience crucial to future project implementation. The project's relative success and experiences (i.e. 82% loan repayment rate, detailed review of the causes behind loan defaults, and monitoring survey results) are detailed herein, providing valuable lessons regarding financial sustainability, the linchpin of successful PV implementation. 8 refs

  16. Energy balance of the global photovoltaic (PV) industry--is the PV industry a net electricity producer?

    Science.gov (United States)

    Dale, Michael; Benson, Sally M

    2013-04-01

    A combination of declining costs and policy measures motivated by greenhouse gas (GHG) emissions reduction and energy security have driven rapid growth in the global installed capacity of solar photovoltaics (PV). This paper develops a number of unique data sets, namely the following: calculation of distribution of global capacity factor for PV deployment; meta-analysis of energy consumption in PV system manufacture and deployment; and documentation of reduction in energetic costs of PV system production. These data are used as input into a new net energy analysis of the global PV industry, as opposed to device level analysis. In addition, the paper introduces a new concept: a model tracking energetic costs of manufacturing and installing PV systems, including balance of system (BOS) components. The model is used to forecast electrical energy requirements to scale up the PV industry and determine the electricity balance of the global PV industry to 2020. Results suggest that the industry was a net consumer of electricity as recently as 2010. However, there is a >50% that in 2012 the PV industry is a net electricity provider and will "pay back" the electrical energy required for its early growth before 2020. Further reducing energetic costs of PV deployment will enable more rapid growth of the PV industry. There is also great potential to increase the capacity factor of PV deployment. These conclusions have a number of implications for R&D and deployment, including the following: monitoring of the energy embodied within PV systems; designing more efficient and durable systems; and deploying PV systems in locations that will achieve high capacity factors. PMID:23441588

  17. Numerical study of PV/T-SAHP system

    Institute of Scientific and Technical Information of China (English)

    Gang PEI; Jie JI; Ke-liang LIU; Han-feng HE; Ai-guo JIANG

    2008-01-01

    In order to utilize solar energy effectively and to achieve a higher electrical efficiency by limiting the operating temperature of the photovoltaic (PV) panel, a novel photovoltaic/thermal solar-assisted heat pump (PV/T-SAHP) system was proposed and constructed. The hybrid solar system generates electricity and thermal energy simultaneously. A distributed parameters model of the PV/T-SAHP system was developed and applied to analyze the system dynamic performance in terms of PV action, photothermal action and Rankine cycle processes. The simulation results indicated that the coefficient of performance (COP) of the proposed PV/T-SAHP can be much better than that of the conventional heat pump. Both PV-efficiency and photothermic efficiency have been improved considerably. The results also showed that the performance of this PV/T-SAHP system was strongly influenced by the evaporator area, tube pitch and tilt angle of the PV/T evaporator, which are the key factors in PV/T-SAHP system optimization and PV/T evaporator design.

  18. Integrating Solar PV in Utility System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved

  19. PV solar electricity: status and future

    Science.gov (United States)

    Hoffmann, Winfried

    2006-04-01

    Within the four main market segments of PV solar electricity there are already three areas competitive today. These are off-grid industrial and rural as well as consumer applications. The overall growth within the past 8 years was almost 40 % p.a. with a "normal" growth of about 18 % p.a. for the first three market segments whereas the grid connected market increased with an astonishing 63 % p.a. The different growth rates catapulted the contribution of grid connected systems in relation to the total market from about one quarter 6 years ago towards more than three quarters today. The reason for this development is basically due to industry-politically induced market support programs in the aforementioned countries. It is quite important to outline under which boundary conditions grid connected systems will be competitive without support programs like the feed in tariff system in Germany, Spain and some more to come in Europe as well as investment subsidies in Japan, US and some other countries. It will be shown that in a more and more liberalized utility market worldwide electricity produced by PV solar electricity systems will be able to compete with their generating cost against peak power prices from utilities. The point of time for this competitiveness is mainly determined by the following facts: 1. Price decrease for PV solar electricity systems leading to an equivalent decrease in the generated cost for PV produced kWh. 2. Development of a truly liberalized electricity market. 3. Degree of irradiation between times of peak power demand and delivery of PV electricity. The first topic is discussed using price experience curves. Some explanations will be given to correlate the qualitative number of 20 % price decrease for doubling cumulative worldwide sales derived from the historic price experience curve with a more quantitative analysis based on our EPIA-Roadmap (productivity increase and ongoing improvements for existing technologies as well as development

  20. PV shading device integrated system in a University Building in Italy

    OpenAIRE

    L.Ceccherini Nelli; F.Cariello; M. Grottke; G.Tondi

    2004-01-01

    PV Enlargement project PV Enlargement" boldly demonstrates Europe’s commitment for improved energy efficiency and cost-effectiveness of PV systems, enhancing the development of large European PV markets. The project can be subdivided into three major fields of activities: Demonstration (1,218 kWp) of highly cost-effective or very innovative PV technologies in 10 European countries for increasing public awareness about and visibility of PV solar electricity Transfer of PV Technol...

  1. Self-control system in storage unit of PV plants

    Energy Technology Data Exchange (ETDEWEB)

    Al-Shaban, Saad; Mohmoud, Ali [Hadhramout Univ. of Science and Technology, Faculty of Engineering, Mukalla (Yemen)

    2000-04-01

    A new system for self-controlling of storage batteries being charged by PV plants has been developed. This provides enhanced system reliability, lower system cost, and simpler operation for the user. In this system, the only requirement is to design and select PV panels so that their voltage-sensitive region (on the I-V curve) coincides with that required for a simpler remote PV plant and for long periods. (Author)

  2. Some aspects of implementing grid-connected PV systems

    OpenAIRE

    Franković, Dubravko; ŽIVIĆ ĐUROVIĆ, Marijana; Saldić, Saša

    2011-01-01

    Generation of electric energy from renewable energy sources is a challenge that has to be carefully envisaged since it represents not only a potentially profitable enterprise but also a source of problems for the complex operation of large electric power systems. The paper presents some aspects of grid-connected photovoltaic (PV) systems, especially the determination of solar potential, selection of PV technology and PV system protection. Finally, some aspects of the impacts due to parallel o...

  3. Maximum Power Point Tracking of PV Arrays using Different Techniques

    OpenAIRE

    N.Bhupesh Kumar; Dr. K. Vijaya Kumar Reddy

    2014-01-01

    The increasing demand for electricity and depleting fossil fuels made the solar Photovoltaic (PV) systems to be a better alternative for the future power requirements. The fact that the output of the PV system is dependent upon the solar irradiance and temperature demands a means to maximize the output of the PV system by continuously tracking the maximum power point(MPP) under changing atmospheric conditions. This paper presents the design and implementation of various techni...

  4. Interrogating Protective Space: Shielding, Nurturing and Empowering Dutch Solar PV

    OpenAIRE

    Bram Verhees; Rob Raven; Frank Veraart; Adrian Smith; Florian Kern

    2012-01-01

    This paper reviews the developments of solar photovoltaic technology in the Netherlands. Despite the recent boom in PV industries and deployment around the globe, the Dutch have until now not experienced major growth in the diffusion of PV electricity generation. But this is only part of the story. This paper focuses on the question why PV is still around in the Netherlands despite, at times, harsh policy and socio-economic contexts. It builds upon a recently developed framework from the fiel...

  5. Design of a Solar Tracker System for PV Power Plants

    OpenAIRE

    Tiberiu Tudorache; Liviu Kreindler

    2010-01-01

    This paper deals with the design and execution of a solar tracker systemdedicated to the PV conversion panels. The proposed single axis solar tracker deviceensures the optimization of the conversion of solar energy into electricity by properlyorienting the PV panel in accordance with the real position of the sun. The operation of theexperimental model of the device is based on a DC motor intelligently controlled by adedicated drive unit that moves a mini PV panel according to the signals rece...

  6. PV window - Development and demonstrations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Haugaard, P.

    2011-05-15

    Using the results from the EU project RenewTransnet, which focused on the development of a pane with integrated solar cells, the goal of this project is to develop these principles into a window solution. This window solution is targeted to Danish building tradition and architecture. It is expected that an elegant PV-window solution for both new and retrofit buildings is developed during this project, and which appearance can be customized to each building. Based on results from a related projects carried out by Gaia Solar, the window solution will have the potential of being approximately 30% cheaper than similar products on the market. In this project this price reduction is the objective of the development of a window solution. The project team has succeeded in developing a 2-layer PV-window with glass / glass lamination with EVA as foil, which is 35% cheaper than similar products on the market. Since the price for the frame-profile does not differ significantly at market level, the price comparison is made on the basis of the developed PV-pane. The objective of 30 % price reduction in relation to similar products on the market is met. A special production process to the making glass/glass lamination with EVA as foil has been developed, in which a frame is put around the module which intends both to remove the unwanted tension along the edges, and to prevent the significant spillage of EVA from the module under pressure and prevent the invasive bubbles along the edge of module. Since the developed production method for making glass/glass modules with EVA is simple, a further cost reduction will primarily be in a reduction of the price of the cell. The project process has resulted in the development of a product, which due to continuous restrictions in the building regulations, will be very attractive in future buildings. (LN)

  7. Solar Energy: Incentives to Promote PV in EU27

    Directory of Open Access Journals (Sweden)

    María del P. Pablo-Romero

    2013-11-01

    Full Text Available The growth in the use of renewable energies in the EU has been remarkable. Among these energies is PV. The average annual growth rate for the EU-27 countries in installed PV capacity in the period 2005-2012 was 41.2%. While the installed capacity of PV has reached almost 82 % of National Renewable Energy Action Plan (NREAP targets for the EU-27 countries for 2020, it is still far from being used at its full potential. Over recent years, several measures have been adopted in the EU to enhance and promote PV. This paper undertakes a complete review of the state of PV power in Europe and the measures taken to date to promote it in EU-27. 25 countries have adopted measures to promote PV. The most widespread measure to promote PV use is Feed- in Tariffs. Tariffs are normally adjusted, in a decreasing manner, annually. Nevertheless, currently, seven countries have decided to accelerate this decrease rate in view of cost reduction of the installations and of higher efficiencies. The second instrument used to promote PV in the EU-27 countries is the concession of subsidies. Nevertheless, subsidies have the disadvantage of being closely linked to budgetary resources and therefore to budgetary constraints. In most EU countries, subsidies for renewable energy for PV are being lowered. Twelve EU-27 countries adopted tax measures. Low-interest loans and green certificate systems were only sparingly used.

  8. Accelerating residential PV expansion: supply analysis for competitive electricity markets

    International Nuclear Information System (INIS)

    Photovoltaic (PV) technology is now sufficiently advanced that market support mechanisms such as net metering plus a renewable portfolio standard (RPS) could induce rapid PV market growth in grid-connected applications. With such support mechanisms, markets would be sufficiently large that manufacturers could profitably build and operate 100 MW p/yr PV module factories, and electricity costs for residential rooftop PV systems would compare favorably with residential electricity prices in certain areas (e.g., California and the greater New York region in the US). This prospect is illustrated by economic and market analyses for one promising technology (amorphous silicon thin-film PV) from the perspectives of both module manufacturers and buyers of new homes with rooftop PV systems. With public policies that reflect the distributed and environmental benefits offered by PV-and that can sustain domestic PV market demand growth at three times the historical growth rate for a period of the order of two decades - PV could provide 3% of total US electricity supply by 2025. (Author)

  9. New financial instruments for PV projects investments

    International Nuclear Information System (INIS)

    The European PV industry is investing heavily in new production facilities. However it is crucial to redouble efforts to overcome the hurdles of the solar electricity market, since only in this way will the sector achieve long-term commercial viability. One of the main objectives will be to work on a series of case studies and identify the project funding mechanisms that would appear to be the most appropriate, with a particular attention paid to the ESCO concept that has already been employed for energy efficiency investments. (authors)

  10. POWERED LED LIGHTING SUPPLIED FROM PV CELLS

    OpenAIRE

    Tirshu M.; Uzun M; Speian A.; Spivac V.; Bogdan A.

    2011-01-01

    The paper deals with practical realization of efficient lighting system based on LED’s of 80W total power mounted on corridor ceiling total length of which is 120m and substitutes existing traditional lighting system consisting of 29 lighting blocks with 4 fluorescent lamps each of them and summary power 2088W. Realized lighting system is supplied from two photovoltaic panels of power 170W. Generated energy by PV cells is accumulated in two accumulators of 75Ah capacity and from battery by me...

  11. Characteristics of laboratory PV/T module

    International Nuclear Information System (INIS)

    The environmental temperature considerably influences the operation mode of silicon photovoltaic elements during the process of electricity generation. Part of solar radiation whose spectrum lies out of the spectral sensitivity of the these elements is usually transformed and dissipated in the space in the form of thermal energy. The purpose of this work is to demonstrate the way of operation and to study experimentally the working parameters of laboratory PV/T module (system), designed to transform and accumulate into useful energy the whole spectrum of the solar radiation

  12. Solar photovoltaic (PV) energy; latest developments in the building integrated and hybrid PV systems

    International Nuclear Information System (INIS)

    Environmental concerns are growing and interest in environmental issues is increasing and the idea of generating electricity with less pollution is becoming more and more attractive. Unlike conventional generation systems, fuel of the solar photovoltaic energy is available at no cost. And solar photovoltaic energy systems generate electricity pollution-free and can easily be installed on the roof of residential as well as on the wall of commercial buildings as grid-connected PV application. In addition to grid-connected rooftop PV systems, solar photovoltaic energy offers a solution for supplying electricity to remote located communities and facilities, those not accessible by electricity companies. The interest in solar photovoltaic energy is growing worldwide. Today, more than 3500MW of photovoltaic systems have been installed all over the world. Since 1970, the PV price has continuously dropped [8]. This price drop has encouraged worldwide application of small-scale residential PV systems. These recent developments have led researchers concerned with the environment to undertake extensive research projects for harnessing renewable energy sources including solar energy. The usage of solar photovoltaic as a source of energy is considered more seriously making future of this technology looks promising. The objective of this contribution is to present the latest developments in the area of solar photovoltaic energy systems. A further objective of this contribution is to discuss the long-term prospect of the solar photovoltaic energy as a sustainable energy supply. [Author

  13. Projecting of PV facades in consideration of PV-specific operating conditions; Besonderheiten bei der Projektierung von Photovoltaik-Fassadenanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Decker, B.; Grimmig, B.; Mencke, D. [Institut fuer Solarenergieforschung GmbH Hameln/Emmerthal (ISFH), Emmerthal (Germany). Gruppe Photovoltaik-Systeme; Stellbogen, D. [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany). Fachgebiet Photovoltaische Anlagentechnik

    1998-02-01

    PV facades can provide several additional functions such as weather protection, thermal insulation, daylighting or sun protection. On the other hand, specific operating conditions for PV facades must be taken into account when selecting components and designing the system. Depending on ventilation conditions, there is a large range of maximum module temperatures. South-oriented PV facades receive about 30% less yearly irradiation than an optimally inclined PV generator, hence reflection losses are approximately 4% higher. The maximum of yearly irradiation lies only in the 400-600 W/m{sup 2} range. Surrounding buildings and/or vegetation can impair performance of the PV-facades. For a south-oriented PV facade an annual yield in the range of 470-560 kwh/kW{sub p}.a has been prodicted which was verified by operating results of eight PV facades. (orig.) [Deutsch] Photovoltaik (PV) Fassaden ermoeglichen neben der Stromerzeugung zusaetzliche Funktionen wie Wetterschutz bzw. Waermedaemmung des Gebaeudes oder Tageslichtnutzung bzw. Sonnenschutz der Innenraeume. Allerdings muessen fassadenspezifische Betriebsbedingungen, bei der Komponentenauswahl und Systemauslegung beruecksichtigt werden. Unterschiedliche Hinterlueftungsbedingungen fuehren zu einer grossen Bandbreite der maximalen Modultemperatur. PV-Suedfassaden empfangen etwa 30% weniger Jahreseinstrahlung als ein optimal geneigter PV-Generator. Die Haelfte der jaehrlichen Einstrahlung trifft mit Einfallswinkeln groesser 50 auf die vertikal angeordneten Module wodurch die Reflexionsverluste um ca. 4% hoeher sind. Das Maximum der Jahreseinstrahlung liegt nur um 400-600 W/m{sup 2} und erreicht selten Werte ueber 800 W/m{sup 2}. Umliegende Gebaeude oder Vegetation koennen zu Teilabschattungen des Generators fuehren. Fuer eine vertikale PV-Suedfassade wird ein Jahresenergieertrag in Hoehe von 470-560 kWh/kW{sub p}.a prognostiziert, der anhand der Betriebsergebnisse von acht PV-Fassadenanlagen verifiziert werden konnte

  14. The potential market for PV building products

    International Nuclear Information System (INIS)

    This study was carried out by ECOTEC Research and Consulting Limited (ECOTEC) in collaboration with the Newcastle Photovoltaic Application Centre (NPAC) and ECD Energy and Environment (ECD) under the Department of Trade and Industry's (DTI) New and Renewable Energy Programme (contract reference S/P2/00277/00/00). The aim was to assess the future market potential for building-integrated photovoltaic (BIPV) products in terms of current product availability, product development needs, the nature and size of the potential market, and the opportunities for government and the PV supply industry to work together to develop the market. The study itself comprised a review of existing BIPV products, an analysis of the development of the world market for BIPV, a market research survey of building professionals, and meetings of two 'focus groups' drawn from the PV 'supply side' and from buildings professionals. In principle, BIPV products can be used in virtually any type of building, but the main applications are considered to be housing and offices. (author)

  15. Impact of residential PV adoption on Retail Electricity Rates

    International Nuclear Information System (INIS)

    The price of electricity supplied from home rooftop photo voltaic (PV) solar cells has fallen below the retail price of grid electricity in some areas. A number of residential households have an economic incentive to install rooftop PV systems and reduce their purchases of electricity from the grid. A significant portion of the costs incurred by utility companies are fixed costs which must be recovered even as consumption falls. Electricity rates must increase in order for utility companies to recover fixed costs from shrinking sales bases. Increasing rates will, in turn, result in even more economic incentives for customers to adopt rooftop PV. In this paper, we model this feedback between PV adoption and electricity rates and study its impact on future PV penetration and net-metering costs. We find that the most important parameter that determines whether this feedback has an effect is the fraction of customers who adopt PV in any year based solely on the money saved by doing so in that year, independent of the uncertainties of future years. These uncertainties include possible changes in rate structures such as the introduction of connection charges, the possibility of PV prices dropping significantly in the future, possible changes in tax incentives, and confidence in the reliability and maintainability of PV. -- Highlights: •Households who install PV reduce their electricity consumption from the grid. •Electricity rates must increase for utility companies to recover its fixed costs. •However, higher electricity rates give households more incentives to adopt PV. •We find that this feedback has significant impact on PV uptake only in later years. •Utility companies could lose a significant fraction of high consumption customers

  16. The Norwegian PV manufacturing industry in a Triple Helix perspective

    International Nuclear Information System (INIS)

    For the benefit of our common future, policies aimed at the development and promotion of renewable energy technologies should be based on a Triple Helix approach with a sense of technological agency. This view is supported by a case study on the emergence and development of a Norwegian solar photovoltaic manufacturing industry. The data and analyses demonstrate how this new industry was fostered by interactions between existing companies, public R and D funding programmes and research organisations and policy contexts; illustrating a policy-driven technological agency in accordance with a Triple Helix innovation process. During the last decade, a solar PV manufacturing industry has emerged in Norway and gone on to a 10 to 20 per cent share of various segments of world markets for solar PV feedstock, wafers and related components. The present financial crisis has caused an investment slump in solar PV installations, especially in Europe. Therefore, the future prospects for the Norwegian solar PV industry are at risk despite of its focus on innovation and R and D, and its technological agency. Political action is needed: (1) creation of market incentives in near markets for the deployment of solar PV, (2) international cooperation for boosting deployment of solar PV in developing countries. - Highlights: • We examine the emergence of the Norwegian solar PV manufacturing industry. • A policy-driven technological agency was essential for the Norwegian PV industry. The Triple Helix model explains the emergence of the Norwegian PV industry. • Market incentives in near markets are needed for the deployment of solar PV. • International cooperation is needed for boosting solar PV in developing countries

  17. Less CO2 by means of photovoltaic energy (PV)

    International Nuclear Information System (INIS)

    Regarding the title subject special attention is paid to the technical limitations of a fast introduction of the use of photovoltaic (PV) energy conversion. After a brief introduction on PV systems and the operation of a solar cell in chapter two, a state of the art is given of PV technology and possible price developments for PV modules and Balance-Of-System (BOS) components up to the year 2000 in chapters three and four. In chapter five the potential of installing grid-connected PV systems in the Netherlands is determined, taking into account the options of using existing buildings (PV systems on the roof), unexplored ground, in the verge of highways or railroads, industrial areas and airports. In chapter six non-economical bottlenecks for a large-scale introduction of grid-connected PV systems are discussed: the industrial production capacity for PV modules and other components, the fitting-in into the public electricity supply, and institutional aspects of installing PV systems on roofs. In chapter seven it is determined how much costs can be saved and CO2 emission can be reduced when PV capacity is fitted-in into the Dutch electric power supply. The calculations are based on the Global Shift scenario. In chapter eight two scenarios (an optimistic scenario and a more realistic scenario) for the introduction of PV systems are outlined. For both scenarios the financial consequences and the contribution to the electric power supply are indicated. In chapter nine the net energy yield, being the result of the previously discussed introduction scenarios, is calculated, followed by a calculation of the avoided CO2 emission, as well as the costs to avoid such emission. 25 figs., 15 tabs., 116 refs., 1 annex

  18. Step-Stress Accelerated Degradation Testing (SSADT) for Photovoltaic (PV) Devices and Cells (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.; Elmore, R.; Suh, C.; Jones, W.

    2010-10-01

    Presentation on step-stress accelerated degradation testing (SSADT) for photovoltaics (PV). Developed are a step-stress degradation test (SSADT) for PV reliability tests and a lifetime prediction model for PV products.

  19. National survey report on PV power applications in Switzerland 2006

    Energy Technology Data Exchange (ETDEWEB)

    Huesser, P. [Nova Energie GmbH, Aarau (Switzerland); Hostettler, T. [Ingenieurbuero Hostettler, Berne (Switzerland)

    2007-07-01

    This annual report was published by the Swiss Federal Office of Energy (SFOE) as part of the International Energy Agency's work on the exchange and dissemination of information on photovoltaic power systems (PVPS). The political situation in Switzerland with regard to the promotion of photovoltaics (PV) and new legislation in the energy area is discussed. The report provides information on installed PV power, costs and prices and the Swiss PV industry. Examples of PV applications are presented and data on the cumulative installed PV power in various application sectors is presented and discussed. Highlights, major projects and various demonstration and field-test programmes are dealt with, as are public budgets for market stimulation. Figures on the development, production and prices of PV cells and modules are presented. Swiss balance-of-system products are reviewed, as are PV-related services and the value of the Swiss PV business. A review of non-technical factors and new initiatives completes the report.

  20. Energy requirements and CO2 mitigation potential of PV systems

    NARCIS (Netherlands)

    Alsema, E.A.

    2006-01-01

    In this paper we investigate the energy requirements of PV modules and systems and calculate the Energy Pay-Back Time for two major PV applications. Based on a review of past energy analysis studies we explain the main sources of differences and establish a "best estimate" for key system components.

  1. MONITOR THE PHOTOVOLTAIC (PV) SYSTEM ON THE NCC ROOFTOP

    Science.gov (United States)

    This study will investigate the pollution emission reduction and demand-side management potential of a100 kW PV system located on the roof of the National Computer Center (NCC). Standardized instrumentation to measure meteorological and PV system performance variables will b...

  2. Robustness analysis of the efficiency in PV inverters

    DEFF Research Database (Denmark)

    Pigazo, Alberto; Liserre, Marco; Blaabjerg, Frede;

    2013-01-01

    During last years an increasing attention has been paid to the efficiency of grid-connected PV inverters. They are manufactured from a number of discrete components and by using a certain topology and control strategy. Hence, the performance of a certain PV inverter not only depends on the select...

  3. Applications of ``PV Optics`` for solar cell and module design

    Energy Technology Data Exchange (ETDEWEB)

    Sopori, B.L.; Madjdpour, J.; Chen, W. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    This paper describes some applications of a new optics software package, PV Optics, developed for the optical design of solar cells and modules. PV Optics is suitable for the analysis and design of both thick and thin solar cells. It also includes a feature for calculation of metallic losses related to contacts and back reflectors.

  4. Development of PV powered consumer products using future scenarios

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Meulen, van der B.J.R.; Eger, A.O.

    2006-01-01

    Given the high potential of PV technology to reduce the environmental impact of electricity use of consumer products, it would be worthwhile to advance the application of PV systems in mass produced products. To date this field of application has been explored only to a limited extent. For this reas

  5. PV-DSM: Policy actions to speed commercialization

    International Nuclear Information System (INIS)

    Pacific Gas and Electric Company (PG ampersand E) recently applied Demand-Side Management (DSM) evaluation techniques to photovoltaic (PV) technology to develop the concept of photovoltaics as a Demand-Side Management option (PV-DSM). The analysis demonstrated that PV-DSM has the potential to be economically attractive. Two criticisms in response to that analysis are that the assumptions of 25 year financing and a 25 year evaluation period are unrealistic. This paper responds to those criticisms and documents the mathematical relationships to calculate the value of PV-DSM from a customer's perspective. It demonstrates how regulatory and government agencies could implement policies to resolve both issues and speed PV commercialization

  6. Costs of Residential Solar PV Plants in Distribution Grid Networks

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Yang, Guangya; Ipsen, Hans Henrik;

    2015-01-01

    In this article we investigate the impact of residential solar PV plants on energy losses in distribution networks and their impact on distribution transformers lifetime. Current guidelines in Denmark states that distribution transformers should not be loaded with more than 67% solar PV power...... to avoid accelerated loss of life. If a solar PV plant causes this limit to be exceeded, the particular owner has to pay for upgrading the transformer. Distribution Network Operators also charge an annual tariff from the solar PV plants to cover the expenses to keep the grid capacity available, the so...... called “Availability Tariff”. According to the Danish Energy Regulatory Authority, the Availability Tariff must cover the exact expenses, with energy savings etc. from the solar PV plants taken into consideration. Our conclusion is that a distribution network, which represents a typical residential...

  7. Optimum Design Of On Grid Pv System Using Tracking System

    Directory of Open Access Journals (Sweden)

    Saeed Mansour

    2015-05-01

    Full Text Available Abstract The fossil fuel is a main issue in the world due to the increase of fossil fuel cost and the depletion of the fossil fuel with continuous increasing demand on electricity. With continuous decrease of PV panels cost it is interesting to consider generation of electricity from PV system. To provide electric energy to a load in a remote area where electric grid utility is not available or connection with grid utility is available there are two approaches of photovoltaic system PV without tracking system Fixed System and PV with tracking systems. The result shows that the energy production by using PV with tracking system generates more energy in comparison with fixed panels system. However the cost per produced KWH is less in case of using fixed panels. This is the backbone in choice between two approaches of photovoltaic system. In this work a system design and cost analysis for two approaches of photovoltaic system are considered.

  8. Fire hazard and other safety concerns of PV systems

    Science.gov (United States)

    Dhere, Neelkanth G.

    2011-09-01

    Photovoltaic modules are usually considered safe and reliable. But in case of grid-connected PV systems that are becoming very popular, the issue of fire safety of PV modules is becoming increasingly important due to the employed high voltages of 600 V to 1000 V. The two main factors i.e. open circuiting of the bypass diode and ground fault that are responsible for the fire in the PV systems have been discussed in detail along with numerous real life examples. Recommendations are provided for preventing the fire hazards such as having at least class C fire rated PV modules, proper bypass and blocking diodes and interestingly, having an ungrounded PV system.

  9. Physical Effects of Distributed PV Generation on California's Distribution System

    CERN Document Server

    Cohen, Michael A

    2015-01-01

    Deployment of high-penetration photovoltaic (PV) power is expected to have a range of effects -- both positive and negative -- on the distribution grid. The magnitude of these effects may vary greatly depending upon feeder topology, climate, PV penetration level, and other factors. In this paper we present a simulation study of eight representative distribution feeders in three California climates at PV penetration levels up to 100\\%, supported by a unique database of distributed PV generation data that enables us to capture the impact of PV variability on feeder voltage and voltage regulating equipment. When comparing the influence of feeder location (i.e. climate) versus feeder type on outcomes, we find that location more strongly influences the incidence of reverse power flow, reductions in peak loading and the presence of voltage excursions. On the other hand, we find that feeder characteristics more strongly influence the magnitude of loss reduction and changes in voltage regulator operations. We find th...

  10. Do feed-in tariffs drive PV cost or viceversa?

    International Nuclear Information System (INIS)

    Highlights: • The distribution of PV installations on the territory is not a function of the solar radiation. • Cost of PV plants were adapted to the FIT framework. • The FIT for PV in Italy was considered an incentive to financial investment. • The FIT for PV in Italy did not stimulate the development of national PV industry. - Abstract: A survey of the PV market in Italy was done studying a number of installations of different sizes whose economic data were known and assessed. The Italian market has experienced a boom in the PV market after the first mechanism of feed-in tariffs was promoted in 2005. The variations of the tariff structure in the following years have caused significant changes in the market structure in terms of average size and technical characteristics of installed plants. However, an Italian PV industry was not stimulated by the incentives and only companies involved in installation and maintenance were created. At the same time, the cost of the PV plants components, design and commissioning have followed quite a particular trend, which is more determined by the tariffs than by the market development and structure. It is quite clear that the costs of PV plants component are not driven by the amount of installations but by the tariffs, with a trend that follows the decreases in the incentives and not the global installed power. It is therefore very important to study the right tariff mechanisms and benefits to avoid financial disturbances on the market and to promote a real competitive market instead of a simple financial operation under a fake façade of green economy

  11. Molecular detection of Xanthomonas oryzae pv. oryzae, Xanthomonas oryzae pv. oryzicola, and Burkholderia glumae in infected rice seeds and leaves

    Science.gov (United States)

    Polymerase chain reaction (PCR) is particularly useful for plant pathogen detection. In the present study, multiplex PCR and SYBR green real-time PCR were developed to facilitate simultaneous detection of three important rice pathogens, Xanthomonas oryzae pv. oryzae, X. oryzae pv. oryzicola, and Bur...

  12. Innovations in Wind and Solar PV Financing

    Energy Technology Data Exchange (ETDEWEB)

    Cory, K.; Coughlin, J.; Jenkin, T.; Pater, J.; Swezey, B.

    2008-02-01

    There is growing national interest in renewable energy development based on the economic, environmental, and security benefits that these resources provide. Historically, greater development of our domestic renewable energy resources has faced a number of hurdles, primarily related to cost, regulation, and financing. With the recent sustained increase in the costs and associated volatility of fossil fuels, the economics of renewable energy technologies have become increasingly attractive to investors, both large and small. As a result, new entrants are investing in renewable energy and new business models are emerging. This study surveys some of the current issues related to wind and solar photovoltaic (PV) energy project financing in the electric power industry, and identifies both barriers to and opportunities for increased investment.

  13. Fidelity Susceptibility as Holographic PV criticality

    CERN Document Server

    Momeni, Davood; Myrzakulov, Ratbay

    2016-01-01

    Motivated by the fact that the quantum entanglement entropy is dual to an area in AdS, quantities dual to a volume in the AdS have also been recently proposed. These include the holographic complexity and fidelity susceptibility of a quantum system. Even though both of them are dual to an volume in the bulk, there are some interesting difference between them. In this letter, we will explicitly compare them for an $ AdS _4$ solution, and clarify the main differences between them from thermodynamic point of the view. We will also obtain the correct and appropriate holographic dual of the thermodynamic volume of AdS blackhole, and demonstrate that to explain therodynamic in extended phase PV picture, from the AdS/CFT point of view,fidelity susceptibility is the preferred quantity in comparison to holographic complexity.

  14. Valley of Death analysis for polymer PV technology; Valley of Death analyse voor polymere PV technologie

    Energy Technology Data Exchange (ETDEWEB)

    Schoots, K. [ECN Beleidsstudies, Petten (Netherlands)

    2013-12-15

    This report describes the results of a qualitative study of the barriers that actors involved in the development and commercialization of polymer solar cells, may encounter. The purpose of this socio-economic research is to identify these barriers for the (market) development of thin film polymeric PV technology and to develop strategies for them in order to overcome the constraints. The necessary data are collected from interviews with actors who are active in the development and deployment of conventional solar cells. Based on the results from this study, it is conclude that it is important for the Organic PV industry to carry out many market experiments beyond the built environment. The report provides recommendations with regard to the markets in which these experiments are most likely to succeed and which drivers should be taken into account [Dutch] Dit rapport beschrijft de resultaten van een kwalitatief onderzoek naar de barrieres die actoren, betrokken bij de ontwikkeling en marktintroductie van polymere zonnecellen, kunnen tegenkomen. Het doel van dit sociaal-economische onderzoek is deze barrieres voor de (markt)ontwikkeling van dunne film polymere PV technologie te identificeren en strategieen te ontwikkelen om ze voor te zijn of ze te overbruggen. De benodigde gegevens worden verzameld uit interviews met actoren die actief zijn in de ontwikkeling en uitrol van conventionele zonnecellen. Op basis van de resultaten uit dit onderzoek komen we tot de conclusie dat het voor de Organische PV sector belangrijk is veel marktexperimenten aan te gaan buiten de gebouwde omgeving. Het rapport geeft aanbevelingen in welke soort markten deze experimenten de meeste kans van slagen hebben en met welke drivers van marktpartijen rekening moet worden gehouden.

  15. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu;

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module......’s impedance spectrum, and further construct an impedance model that can link environmental changes to the model’s parameters. To achieve this, an optimized setup has been developed for long-term impedance spectra monitoring synchronised with accurate irradiance and temperature data. Preliminary results show...... clear correlation between the determined parameters and ambient conditions....

  16. What's stopping a huge expansion of the PV market?

    International Nuclear Information System (INIS)

    Over the past 25 years the terrestrial PV industry has turned into a billion-dollar global business. The necessary technology is available and substantial market growth is continuing. It has often been said that the cost of PV must come down further before the technology really takes off. However the author argues here that the dominant segments of the market are not price-sensitive and that the future explosive expansion of PV markets will need financing on a global basis, assured quality in the products, and the institution of an extensive public-awareness programme of advertising, promotion and education. (author)

  17. Design of a Solar Tracker System for PV Power Plants

    Directory of Open Access Journals (Sweden)

    Tiberiu Tudorache

    2010-04-01

    Full Text Available This paper deals with the design and execution of a solar tracker systemdedicated to the PV conversion panels. The proposed single axis solar tracker deviceensures the optimization of the conversion of solar energy into electricity by properlyorienting the PV panel in accordance with the real position of the sun. The operation of theexperimental model of the device is based on a DC motor intelligently controlled by adedicated drive unit that moves a mini PV panel according to the signals received from twosimple but efficient light sensors. The performance and characteristics of the solar trackerare experimentally analyzed.

  18. Durability Quality Research of Concrete Containing Solar PV Cells

    OpenAIRE

    Chao Sao-Jeng; Cheng An; Hsu Hui-Mi; Chang Jia-Ruey; Teng Li-Wei; Chen Sung-Ching

    2015-01-01

    In this article we demonstrated the study results of durability quality of concrete containing waste solar PV cells. The study used alkali activator to improve the activity of alkali-activated materials in solar PV cells so as to replace Portland cement as binder in concrete. By using sodium hydroxide as an alkali-activator, a high-pH environment is generated to excite the binding characteristics of alkali-activated materials in solar PV cells, and thus develops better durability of the mixes...

  19. PV-Wind Hybrid Systems for Swedish Locations

    OpenAIRE

    Fiedler, Frank; Pazmino, Victor; Berruezo, Irati

    2008-01-01

    PV-Wind-Hybrid systems for stand-alone applications have the potential to be more cost efficient compared to PV-alone systems. The two energy sources can, to some extent, compensate each others minima. The combination of solar and wind should be especially favorable for locations at high latitudes such as Sweden with a very uneven distribution of solar radiation during the year. In this article PV-Wind-Hybrid systems have been studied for 11 locations in Sweden. These systems supply the house...

  20. Design Considerations for Stand-Alone Photovoltaic (PV) Cell Applications

    OpenAIRE

    Mehmet Cebeci; Ahmet Şenpinar

    2013-01-01

    Solar energy is one of the most important renewable energy sources. The photovoltaic (PV) cell systems are used to convert solar energy into electricity. PV systems are divided into two as fixed systems and tracking systems. Fixed systems are mounted at a certain tilt with horizontal to make full use of sunlight. The tilt angle of PV arrays in a fixed system depends on the location and time. If this tilt angle is determined well, the amount of insolation and the energy that is generated incre...

  1. PV Validation and Bankability Workshop: San Jose, California

    Energy Technology Data Exchange (ETDEWEB)

    Granata, J.; Howard, J.

    2011-12-01

    This report is a collaboration between Sandia National Laboratories, the National Renewable Energy Laboratory, and the Florida Solar Energy Center (FSEC). The report provides feedback from the U.S. Department of Energy's (DOE) Solar Program PV Validation and Bankability Workshop in San Jose, California on August 31, 2011. It focuses on the current state of PV in the United States, private funding to fund U.S. PV industry growth, roles and functions of the regional test center program, and ways to improve the current validation and bankability practices.

  2. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented....... The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed...

  3. Recent developments in ASSERT-PV code for subchannel thermalhydraulics

    International Nuclear Information System (INIS)

    This paper summarises recent development of ASSERT-PV, and provides examples of applications to CANDU fuel bundles in predicting flow, heat transfer and sheath temperatures. The development work is intended to improve computational and phenomenological modelling capabilities of ASSERT-PV in simulating various flow scenarios in CANDU fuel bundles. The latest version of ASSERT-PV can be used for simulations of steady state or transient, subchannel thermalhydraulics in CANDU bundles under conditions up to and including post-dryout heat transfer. (author)

  4. Measures for diffusion of solar PV in selected African countries

    DEFF Research Database (Denmark)

    Nygaard, Ivan; Hansen, Ulrich Elmer; Mackenzie, Gordon A.;

    2015-01-01

    from 2010 to 2013. The paper provides a review of three distinct but characteristic trajectories for PV market development in Kenya (private-led market for solar home systems), Morocco (utility-led fee-for service model) and Rwanda (donorled market for institutional systems). The paper finds that...... governments’ strategies to promoting solar PV are moving from isolated projects towards frameworks for market development and that there are high expectations to upgrading in the PV value chain through local assembly of panels and local production of other system elements. Commonly identified measures include...

  5. The sol-ion system. A stationary PV battery system

    Energy Technology Data Exchange (ETDEWEB)

    Schmiegel, A.U.; Knaup, P.; Meissner, A. [voltwerk electronics GmbH, Hamburg (Germany); Jehoulet, C.; Schuh, H. [Saft Batteries, Bordeaux (France); Landau, M.; Braun, M. [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany); Sauer, D.U.; Magnor, D. [RWTH Aachen (Germany). ISEA; Mohring, H.D. [ZSW, Stuttgart (Germany)

    2010-07-01

    Stationary PV battery systems will play a more important role in future PV applications. They are able to support the grid by providing active and reactive power that can be stored and they can be used to increase the self-consumption of solar energy. The Sol-ion system is a PV battery system that utilises two different approaches for self-consumption - either disconnected from or connected to the grid. Instead of traditional lead-acid batteries, this system uses lithium-ion batteries to store solar power more efficiently. (orig.)

  6. A system for optimization working parameters of PV-modules and PV-generators at high environmental temperature

    International Nuclear Information System (INIS)

    Installing PV-modules and PV generators in some cases suffers from the lack of possibilities for choosing suitable platforms for situating them due to various architectural and constructive limitations. Therefore these modules and generators are often mounted on dark surfaces. As a consequence, their working temperature rises, which leads to lowing their coefficient of efficiency. This paper suggests a system for automatic temperature control and regulation for PV-modules and generators, which aims at optimization of their operation and efficiency. There are some experimental results shown in the paper, illustrating the efficiency of the system. (author)

  7. Photovoltaic (PV) contribution to the primary frequency control

    International Nuclear Information System (INIS)

    Photovoltaic (PV) technology is among the most efficient and cost effective renewable energy kinds currently available on the market. The connection of a large number of PVs to the grid may influence the frequency and voltage stability of the power system. This paper proposes load-frequency control technique for system with high penetration of photovoltaic (PV). The proposed controller has been successfully implemented and tested using PSCAD/EMTDC. In this study, the impact of photovoltaic (PV) on frequency stability of the system is studies in detail. This study shows that large penetration of photovoltaic (PV) with load and frequency control has a significant impact on the stability and security level of electrical network.(author)

  8. Design Considerations for Stand-Alone Photovoltaic (PV Cell Applications

    Directory of Open Access Journals (Sweden)

    Mehmet Cebeci

    2013-06-01

    Full Text Available Solar energy is one of the most important renewable energy sources. The photovoltaic (PV cell systems are used to convert solar energy into electricity. PV systems are divided into two as fixed systems and tracking systems. Fixed systems are mounted at a certain tilt with horizontal to make full use of sunlight. The tilt angle of PV arrays in a fixed system depends on the location and time. If this tilt angle is determined well, the amount of insolation and the energy that is generated increases. When a stand-alone PV cell system is being chosen, certain design operations should be implemented. The number of modules and batteries needed for any system should be calculated by means of the amount of load, insolation level, module characteristics, etc. The design of system is finalized according to the energy demand.

  9. PV GRID Advisory Paper. Consultation version: key recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Bianca; Concas, Giorgia; Cossent, Rafael; Franz, Oliver; Frias, Pablo; Hermes, Roland; Lama, Riccardo; Loew, Holger; Mateo, Carlos; Rekinger, Manoel; Sonvilla, Paolo Michele; Vandenbergh, Michel

    2014-01-15

    PV GRID is a transnational collaborative effort under the umbrella of the Intelligent Energy Europe programme. The main project goal is to enhance photovoltaic (PV) hosting capacity in distribution grids while overcoming regulatory and normative barriers hampering the application of available technical solutions. The European PV GRID advisory paper aims at providing an overview of the issues and barriers that need to be addressed in order to enhance the distribution grid hosting capacity for PV and other distributed generation (DG).To this purpose, barriers are classified as either cross-cutting challenges or specific barriers, depending on whether they have an overarching, system-wide character or rather focus on one single issue such as curtailment, self-consumption or storage. Finally, a set of preliminary recommendations on how to overcome these issues is presented, allowing for the implementation of the identified technical solutions.

  10. Races and hosts of Pseudomonas syringae pv. tomato in Serbia

    Directory of Open Access Journals (Sweden)

    Milijašević Svetlana

    2009-01-01

    Full Text Available During the past few years, frequent appearance of bacterial speck of tomatoes was recorded in several tomato-growing regions in Serbia. A three-year survey of tomato fields in Serbia (2002-2004 resulted in the isolation of numerous bacterial strains, with 30 representative strains selected for further analyses. Based on the results of pathogenicity, biochemical, and physiological tests, all strains isolated from diseased tomato plants were identified as P. syringae pv. tomato. The identity of strains was confirmed by the polymerase chain reaction (PCR, since PCR products of expected size (650 bp specific for coronatine-producing strains of P. syringae pv. tomato were amplified from all tested strains. Study of the host range of P. syringae pv. tomato strains originating from Serbia confirmed tomato as the sole host. The reaction of tomato differential cultivar Ontario 7710 showed that the Serbian strains belonged to races 0 and 1 of P. syringae pv. tomato.

  11. New test and characterization methods for PV modules and cells

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.; Sommeling, P. [ECN Solar Energy, Petten (Netherlands); Scholten, H. [Solland, Heerlen (Netherlands); Muller, J. [Moser-Baer, Eindhoven (Netherlands); Grossiord, N. [Holst Centre, Eindhoven (Netherlands); Smits, C.; Blanco Mantecon, M. [Holland Innovative, Eindhoven (Netherlands); Verheijen, M.; Van Berkum, J. [Philips Innovation Services, Eindhoven (Netherlands)

    2012-08-15

    The results of the project geZONd (shared facility for solar module analysis and reliability testing) are described. The project was set up by Philips, ECN, Holst, Solland, OM and T and Holland Innovative. The partners have shared most of their testing and analysis equipment for PV modules and cells, and together developed new or improved methods (including the necessary application know-how). This enables faster and more efficient innovation projects for each partner, and via commercial exploitation for other interested parties. The project has concentrated on five failure modes: corrosion, delamination, moisture ingress, UV irradiation, and mechanical bending. Test samples represented all main PV technologies: wafer based PV and rigid and flexible thin-film PV. Breakthroughs are in very early detection of corrosion, in quantitative characterization of adhesion, in-situ detection of humidity and oxygen inside modules, and ultra-fast screening of materials on UV stability.

  12. Full Steam Ahead for PV in US Homes?

    Energy Technology Data Exchange (ETDEWEB)

    Bolinger, Mark A; Barbose, Galen; Wiser, Ryan

    2009-01-15

    In October 2008, the United States Congress extended both the residential and commercial solar investment tax credits (ITCs) for an unprecedented eight years, lifted the $2,000 cap on the residential credit, removed the prohibition on utility use of the commercial credit, and eliminated restrictions on the use of both credits in conjunction with the Alternative Minimum Tax. These significant changes, which apply to systems placed in service on or after January 1, 2009, will increase the value of the solar credits for residential system owners in particular, and are likely--in conjunction with state, local, and utility rebate programs targeting solar--to spur significant growth in residential, commercial, and utility-scale photovoltaic (PV) installations in the years ahead. This article focuses specifically on the residential credit, describing three areas in which removal of the $2,000 cap on the residential ITC will have significant implications for PV rebate program administrators, PV system owners, and the PV industry.

  13. The Ramakrishna Mission economic PV development initiative

    Energy Technology Data Exchange (ETDEWEB)

    Stone, J.L.; Ullal, H.S. [National Renewable Energy Lab., Golden, CO (United States); Sherring, C. [Sherring Energy Associates, Princeton, NJ (United States)

    1998-09-01

    India is the world`s second most populous country, quickly approaching one billion persons. Although it has a well-developed electricity grid, many of the people have little or no access to electricity and all of the benefits associated with it. There are areas that are isolated from the grid and will not be connected for many years, if ever. One such area is the Sundarbans located in the delta region of the two great rivers, the Ganges and Brahmaputra, partially in India and partially in Bangladesh. It is estimated that 1.5 million people live in this area, crisscrossed by many islands and rivers, who have only marginal supplies of electricity generated primarily from diesel generators and batteries. Working with the regional non-governmental organization (NGO), the Ramakrishna Mission, and the West Bengal Renewable Energy Development Agency, the governments of India and the US initiated a rural electrification initiative to demonstrate the economic and technical feasibility of photovoltaics to provide limited supplies of electricity for such applications as solar home lighting systems (SHS), water pumping, vaccine refrigeration, communications, and economic development activities. This paper details initial results from approximately 30 kilowatts of PV systems installed in the area, including socio-economic impacts and technical performance.

  14. Electrification of rural areas by solar PV

    International Nuclear Information System (INIS)

    More than 2000 million people, mostly in developing countries, live in rural areas without access to grid connected power. Conventional approaches to supplying power, whether through extension of existing grids or through stand-alone 'mini-grids' based on diesel generator sets, or even on renewable energy minigrids, require large investments which are unlikely to receive priority in competition with more economically and politically attractive investments in urban areas. Domestic PV lighting and broadcast reception kits (DLKs), comprising, typically, a 30-60 W panel, an automotive battery, a charge indicator, and dc fluorescent lamps can be furnished and installed for about $500. DLKs are now used in the Dominican Republic, Kenya, Sri Lanka and many other countries. DLKs provide a minimum essential service with low overheads. Given the necessary credit facilities, they can give better service at comparable costs in comparison with kerosene lamps and dry cell powered radios. They also permit a substantial degree of local manufacture, thus saving on foreign exchange. This movement is starting in many countries on a purely commercial basis. The process could be greatly accelerated if 'seed money' in the form of revolving funds could be made available. (author). 1 fig., 11 tabs

  15. Performance parameters of a standalone PV plant

    International Nuclear Information System (INIS)

    Highlights: • We described in details a photovoltaic power plant installed in the remote rural village Elkaria (Essaouira Morocco – 7.2 kWp). • We presented the results of monitoring and some performance parameters of the plant such as load curve. • We discussed the energy management of the plant which is based on the droop mode control. • We presented and discussed the yields and the performance ratio of the plant. - Abstract: In this work we present a detailed description of a 7.2 kWp photovoltaic power plant installed in the remote rural village Elkaria (province of Essaouira in Morocco). This plant supplies 16 households with electricity through a local grid that was installed for this purpose. The results of monitoring some performance parameters of the plant such as load curve, the yields and the performance ratio are presented and discussed. The performance ratio of the PV plant varied between 33% and 70.2%. The low values of this parameter are mainly attributed to the way the battery inverter manages the energy flow

  16. Promotional drivers for grid-connected PV

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Polo, A.; Hass, R.; Suna, D.

    2009-03-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at promotional measures for grid-connected photovoltaic systems. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. The objective of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. The paper discusses the core objective of this study which was to analyse the success of various governmental regulatory programs and governmental and non-governmental marketing programs for grid-connected PV systems. To meet this objective, a review of the most important past and current programs around the world was conducted. The theoretical bases of supply and demand are explained and the types of existing strategies are documented in a second Section. In Chapter 3, various programs around the world are described. Chapter 4 focuses on defining success criteria which will be used for the analysis of the programs. Finally, the major conclusions drawn complete this analysis.

  17. Evaluation of PV Module Field Performance

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, John; Silverman, Timothy; Miller, David C.; McNutt, Peter; Kempe, Michael; Deceglie, Michael

    2015-06-14

    This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.

  18. Hospedeiros alternativos de Xanthomonas campestris pv. viticola Alternative hosts of Xanthomonas campestris pv. viticola

    OpenAIRE

    Ana Rosa Peixoto; Rosa L.R. Mariano; José Osmã T. Moreira; Ivanise O. Viana

    2007-01-01

    Xanthomonas campestris pv. viticola (Xcv), que causa o cancro bacteriano da videira, sobrevive em plantas infectadas, epifiticamente em órgãos da parte aérea e pode ser veiculada em mudas e/ou bacelos infectados. O trabalho teve como objetivo investigar possíveis hospedeiros alternativos do patógeno, visando fornecer subsídios para o manejo da doença. A partir das plantas invasoras Alternanthera tenella, Amaranthus sp., Glycine sp. e Senna obtusifolia com sintomas similares aos do cancro bact...

  19. Trends in building integrated PV: results from the IEA PV Power Systems Programme

    International Nuclear Information System (INIS)

    This paper reviews trends in the market for BIPV systems. The market for BIPV systems is expanding rapidly and is being promoted by demonstration and market incentive programmes being undertaken in various countries. The rate of expansion of the market is quantified and trends in the technology are discussed. The paper draws on work undertaken by the author as one of the UK representatives to Task 7 of the IEA PV Power Systems Programme and as technical writer for the International Survey Report produced by Task 1. (author)

  20. PV and gas turbine system for peak-demand applications

    International Nuclear Information System (INIS)

    A computer simulation model of the behavior of a photovoltaic (PV) gas turbine hybrid system with compressed air storage is developed in order to evaluate its performance and predict the total energy-conversion efficiency and the incurred costs under various operating conditions. This integrated PV and gas turbine hybrid plant produces approximately 140% more power per unit of energy consumed compared with conventional gas turbine plants. In addition lower rates of pollutant emissions to the atmosphere are achieved.(Author)

  1. Microgrid-Ready Solar PV; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-07-01

    Designing new solar projects to be 'microgrid-ready' enables the U.S. DoD, other federal agencies, and the private sector to plan future microgrid initiatives to utilize solar PV as a generating resource. This fact sheet provides background information with suggested language for several up-front considerations that can be added to a solar project procurement or request for proposal (RFP) that will help ensure that PV systems are built for future microgrid connection.

  2. Design and Implementation of A PV Powered Tri-Cycle

    OpenAIRE

    Soumya Das; Pradip K Sadhu; Suprava Chakraborty; Saumen Dhara; Shramabati Sen

    2016-01-01

    Solar PV technology is one of the first among the various renewable energy technologies that have been adopted and accepted universally in order to meet the basic needs of generation of electricity. The objective of this paper is to propose a tri-cycle that utilises the application of stand-alone photovoltaic (PV) system. A preliminary design and construction of a solar tri-cycle has been performed by evaluating and estimating the required panel size, battery capacity and motor power. Calcul...

  3. Developing solar: PV solar system markets in Africa

    International Nuclear Information System (INIS)

    Governments, NGO's and UN organisations are increasingly convinced that renewable energies not only help to solve energy problems in Africa but are indispensable in alleviating regional disparities, social problems and bridging the digital gap. Still, many years after introducing high efficiency solar PV systems the necessary breakthrough of implementing them on a mass scale is still not a reality. The author provides perspectives on developing solar PV in Africa. (Author)

  4. Design of fibre reinforced PV concepts for building integrated applications

    OpenAIRE

    Reinders, A.H.M.E.; Wit, de, S.; Boer

    2009-01-01

    Fibre reinforced polymers present an interesting encapsulation medium for PV-modules. Glass fibres can provide increased strength and stiffness to thin polymer layers overcoming the brittleness and limited deformability of glass-panes. Glass fibre reinforced polymers allows for transparency over a broad range of the solar spectrum while the material properties and integral production processes create possibilities for novel product concepts with embedded PV technology. To explore such possibi...

  5. Thermal Evaluation of a Solarus PV-T collector

    OpenAIRE

    Haddi, Jihad

    2013-01-01

    Low concentrator PV-T hybrid systems produce both electricity and thermal energy; this fact increases the overall efficiency of the system and reduces the cost of solar electricity. These systems use concentrators which are optical devices that concentrate sunlight on to solar cells and reduce expensive solar cell area. This thesis work deals with the thermal evaluation of a PV-T collector from Solarus.Firstly the thermal efficiency of the low concentrator collector was characterized for the ...

  6. System analysis of a PV/T hybrid solar window

    OpenAIRE

    Davidsson, Henrik

    2010-01-01

    A building-integrated multifunctional PV/T solar window was suggested and developed by Andreas Fieber. The solar window is constructed of PV cells laminated on solar absorbers placed in a window behind the glazing. To reduce the costs of solar electricity, tiltable reflectors have been introduced in the construction to focus radiation onto the solar cells. The reflectors make it possible to control the amount of radiation transmitted into the building. The insulated reflectors also reduce the...

  7. P-V Criticality of Modified BTZ Black Hole

    Science.gov (United States)

    Sadeghi, J.; Kubeka, A. S.

    2016-05-01

    In this paper, we investigate the BTZ black hole in P-V critical point of view. As we know, the BTZ black hole does not have P-V critical behavior. So in this case, we introduce some anstaz that give us the modified BTZ black hole. Finally, we show that this modified BTZ black hole is satisfied by the equation of state of Liquid-gas phase transition.

  8. Control and operation of SMES and SMES/PV systems

    OpenAIRE

    Foreman, Mark McKinney

    1992-01-01

    Applications, converter topologies, and control schemes are examined for superconductive magnetic energy storage (SMES) systems. Diurnal load leveling for electric utilities and compensation for fluctuations in photovoltaic (PV) power generation are the primary applications discussed. It is demonstrated that a SMES system implemented with standard AC/DC converters offers energy storage capacity large enough, and dynamic response fast enough, to compensate for PV fluctuat...

  9. Economic and policy analysis for solar PV systems in Indiana

    International Nuclear Information System (INIS)

    In recent years, the energy market in the US and globally is expanding the production of renewable energy. Solar energy for electricity is also expanding in the US. Indiana is one of the states expanding solar energy with solar photovoltaic (PV) systems. Therefore, we conduct benefit cost analysis with several uncertain input variables to determine the economics of adopting solar PV systems in Indiana based on policy instruments that could increase adoption of solar PV systems. The specific objectives are analyses of the cost distribution of solar PV systems compared with grid electricity in homes and estimating the probability that solar can be cheaper than electricity from grids under different policy combinations. We first do the analysis under current policy and then the analysis under potential policy options for a variety of scenarios. Also, the results inform government policy makers on how effective the alternative policies for encouraging solar PV systems are. The results show that current policies are important in reducing the cost of solar PV systems. However, with current policies, there is only 50–50 chance of solar being cheaper than electricity from grids. If potential policies are implemented, solar PV systems can be more economical than grid electricity. - Highlights: • We investigate the economics of solar PV systems based on policy instruments. • We do scenario analyses under different combinations of policies. • We examine the probability of solar being cheaper than grid electricity for each scenario. • With current policies, there is 50–50 chance of solar being cheaper than the grid. • With depreciation and carbon tax, solar is much more economical than the grid

  10. Real Time Photovoltaic Array Simulator for Testing Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sera, Dezso; Valentini, Massimo; Raducu, Alin

    2008-01-01

    In this paper a real time flexible PV array simulator is presented. It is a system that can simulate different PV panel arrays in specific environmental conditions. To evaluate performance of the Maximum Power Point Tracking (MPPT) of grid-connected Photovoltaic (PV) inverters only measurements u...... undertaken with an appropriate PV array simulator provide accurate and reproducible results. Thus the PV array simulator has been developed and implemented. MPPT efficiency tests on a commercial grid-connected PV inverter have been performed to validate the PV array simulator....

  11. PV Derived Data for Predicting Performance; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill

    2015-09-14

    A method is described for providing solar irradiance data for modeling PV performance by using measured PV performance data and back-solving for the unknown direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI), which can then be used to model the performance of PV systems of any size, PV array tilt, or PV array azimuth orientation. Ideally situated for using the performance data from PV modules with micro-inverters, the PV module operating current is used to determine the global tilted irradiance (GTI), and a separation model is then used to determine the DNI and DHI from the GTI.

  12. Review of PV Inverter Technology Cost and Performance Projections

    Energy Technology Data Exchange (ETDEWEB)

    Navigant Consulting Inc.

    2006-01-01

    The National Renewable Energy Laboratory (NREL) has a major responsibility in the implementation of the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program. Sandia National Laboratories (SNL) has a major role in supporting inverter development, characterization, standards, certifications, and verifications. The Solar Energy Technologies Program recently published a Multiyear Technical Plan, which establishes a goal of reducing the Levelized Energy Cost (LEC) for photovoltaic (PV) systems to $0.06/kWh by 2020. The Multiyear Technical Plan estimates that, in order to meet the PV system goal, PV inverter prices will need to decline to $0.25-0.30 Wp by 2020. DOE determined the need to conduct a rigorous review of the PV Program's technical and economic targets, including the target set for PV inverters. NREL requested that Navigant Consulting Inc.(NCI) conduct a review of historical and projected cost and performance improvements for PV inverters, including identification of critical barriers identified and the approaches government might use to address them.

  13. Energy metrics analysis of hybrid - photovoltaic (PV) modules

    Energy Technology Data Exchange (ETDEWEB)

    Tiwari, Arvind [Department of Electronics and Communication, Krishna Institute of Engineering and Technology, 13 k.m. stone, Ghaziabad - Meerut Road, Ghaziabad 201 206, UP (India); Barnwal, P.; Sandhu, G.S.; Sodha, M.S. [Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016 (India)

    2009-12-15

    In this paper, energy metrics (energy pay back time, electricity production factor and life cycle conversion efficiency) of hybrid photovoltaic (PV) modules have been analyzed and presented for the composite climate of New Delhi, India. For this purpose, it is necessary to calculate (1) the energy consumption in making different components of the PV modules and (2) the annual energy (electrical and thermal) available from the hybrid-PV modules. A set of mathematical relations have been reformulated for computation of the energy metrics. The manufacturing energy, material production energy, energy use and distribution energy of the system have been taken into account, to determine the embodied energy for the hybrid-PV modules. The embodied energy and annual energy outputs have been used for evaluation of the energy metrics. For hybrid PV module, it has been observed that the EPBT gets significantly reduced by taking into account the increase in annual energy availability of the thermal energy in addition to the electrical energy. The values of EPF and LCCE of hybrid PV module become higher as expected. (author)

  14. Training and certification of PV installers in Europe

    International Nuclear Information System (INIS)

    The European strategy for the coming decades sets specific targets for a sustainable growth, including reaching a 20% share of renewables in final energy consumption till 2020. To achieve this target, a number of initiatives and measures have been in force. Europe, is currently the largest market for PV systems with more than 75% of the annual worldwide installations in 2011. The favourable European policies as well as the Member States’ supporting legislations have resulted in high market growth for photovoltaics. Applying PV technologies however, requires high qualified technicians to install, repair and maintain them. Until today, national markets have been growing faster than the skilled PV installers force can satisfy. The PVTRIN, an Intelligent Energy Europe action, addresses these issues by developing a training and certification scheme for technicians active in the installation and maintenance of small scale PV systems. During the implementation of the action, a market research was conducted in the six participating countries in order to record the stakeholders’ attitudes, perceptions and considerations and to adapt the training methods, tools and materials to the national PV industry requirements and markets’ needs. Indicative results of this analysis as well as the current situation regarding relevant training and certification schemes are presented in this paper. - Highlights: ► Market research in six EU countries on PV professional Training and Certification needs. ► PVTRIN scheme integrates the national legislations and the market's needs. ► The different aspects (technical, institutional, financial) are presented

  15. Performance evaluation of stand alone hybrid PV-wind generator

    Science.gov (United States)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-05-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  16. Performance evaluation of stand alone hybrid PV-wind generator

    International Nuclear Information System (INIS)

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand

  17. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  18. Performance evaluation of stand alone hybrid PV-wind generator

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H. [Faculty of Electrical Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia); Yahaya, M. S. [Faculty of Engineering Technology, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia)

    2015-05-15

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  19. Examples of successful architectural integration of PV: Germany

    International Nuclear Information System (INIS)

    In Germany building-integrated photovoltaics (BIPV) are developing rapidly, and much progress has been achieved in the past five years. BIPV can be used today in different ways on both existing and new buildings. Architects and designers are discovering BIPV. With the help of custom-made products available on the German market they are beginning to explore the technical limits of an aesthetic and structural integration of PV in buildings. As a result some exciting high-profile building projects with PV have been built, for example, the small service pavilion Meereslauschen in Steinhude or the new headquarters building of the Wood Trade Association in Munich. These projects show that the use of PV is very varied and offers opportunities for creative architects. However non-technical problems still need to be solved to allow a meaningful and widespread application of PV in the built environment. To decrease costs it is essential to develop further standard BIPV components. The aim of such developments should be to replace standard PV modules by products in which PV and structural building elements are melded into one design and structural unit. (author)

  20. Battery Energy Storage System for PV Output Power Leveling

    Directory of Open Access Journals (Sweden)

    Rajkiran Singh

    2014-01-01

    Full Text Available Fluctuating photovoltaic (PV output power reduces the reliability in power system when there is a massive penetration of PV generators. Energy storage systems that are connected to the PV generators using bidirectional isolated dc-dc converter can be utilized for compensating the fluctuating PV power. This paper presents a grid connected energy storage system based on a 2 kW full-bridge bidirectional isolated dc-dc converter and a PWM converter for PV output power leveling. This paper proposes two controllers: a current controller using the d-q synchronous reference and a phase-shift controller. The main function of the current controller is to regulate the voltage at the high-side dc, so that the voltage ratio of the high-voltage side (HVS with low-voltage side (LVS is equal to the transformer turns ratio. The phase-shift controller is employed to manage the charging and discharging modes of the battery based on PV output power and battery voltage. With the proposed system, unity power factor and efficient active power injection are achieved. The feasibility of the proposed control system is investigated using PSCAD simulation.

  1. Continuing Developments in PV Risk Management: Strategies, Solutions, and Implications

    Energy Technology Data Exchange (ETDEWEB)

    Lowder, T.; Mendelsohn, M.; Speer, B.; Hill, R.

    2013-02-01

    As the PV industry matures, successful risk management practices will become more imperative to ensure investor confidence, control costs, and facilitate further growth. This report discusses several key aspects of risk management during the commercial- and utility-scale project life cycle, from identification of risks, to the process of mitigating and allocating those risks among project parties, to transferring those risks through insurance. The report also explores novel techniques in PV risk management, options to offload risks onto the capital markets, and innovative insurance policies (namely warranty policies) that address risks unique to the PV sector. One of the major justifications for robust risk management in the PV industry is the cost-reduction opportunities it affords. If the PV industry can demonstrate the capability to successfully manage its risks, thereby inspiring confidence in financiers, it may be able to obtain a lower cost of capital in future transactions. A lower cost of capital translates to a lower cost of energy, which will in turn enhance PV?s competitiveness at a time when it will have to rely less on subsidies to support its market penetration.

  2. Residential Solar PV Systems in the Carolinas: Opportunities and Outcomes.

    Science.gov (United States)

    Alqahtani, Bandar Jubran; Holt, Kyra Moore; Patiño-Echeverri, Dalia; Pratson, Lincoln

    2016-02-16

    This paper presents a first-order analysis of the feasibility and technical, environmental, and economic effects of large levels of solar photovoltaic (PV) penetration within the services areas of the Duke Energy Carolinas (DEC) and Duke Energy Progress (DEP). A PV production model based on household density and a gridded hourly global horizontal irradiance data set simulates hourly PV power output from roof-top installations, while a unit commitment and real-time economic dispatch (UC-ED) model simulates hourly system operations. We find that the large generating capacity of base-load nuclear power plants (NPPs) without ramping capability in the region limits PV integration levels to 5.3% (6510 MW) of 2015 generation. Enabling ramping capability for NPPs would raise the limit of PV penetration to near 9% of electricity generated. If the planned retirement of coal-fired power plants together with new installations and upgrades of natural gas and nuclear plants materialize in 2025, and if NPPs operate flexibly, then the share of coal-fired electricity will be reduced from 37% to 22%. A 9% penetration of electricity from PV would further reduce the share of coal-fired electricity by 4-6% resulting in a system-wide CO2 emissions rate of 0.33 to 0.40 tons/MWh and associated abatement costs of 225-415 (2015$ per ton). PMID:26745347

  3. A Software Tool for Optimal Sizing of PV Systems in Malaysia

    OpenAIRE

    K. Sopian; Azah Mohamed; Tamer Khatib

    2012-01-01

    This paper presents a MATLAB based user friendly software tool called as PV.MY for optimal sizing of photovoltaic (PV) systems. The software has the capabilities of predicting the metrological variables such as solar energy, ambient temperature and wind speed using artificial neural network (ANN), optimizes the PV module/ array tilt angle, optimizes the inverter size and calculate optimal capacities of PV array, battery, wind turbine and diesel generator in hybrid PV systems. The ANN based mo...

  4. Modelling of grid connected geographically dispersed PV systems for power system studies

    OpenAIRE

    Ramachandran, Jayaraman

    2005-01-01

    ABSTRACT The growth of the photovoltaic market indicates that in the near future PV electricity generation may rise to a significant power source. As the proportion of electric power generated from PV systems becomes significant, the effect of these sources on transmission and distribution networks must be considered. This research work has investigated suitable representations of the PV resource and the output power of dispersed PV systems to study the effects of large-scale deployment of PV...

  5. Effect of the Fluctuations of PV Production and Electricity Demand on the PV Electricity Self-Consumption

    OpenAIRE

    Wyrsch, Nicolas; Riesen, Yannick; Ballif, Christophe

    2013-01-01

    The electricity self-consumption level of a family household is determined both experimentally and by modelling. The effect of rapid fluctuation in PV production and electricity demand, and especially the effect of the temporal resolution of their measurements, are studied. For accurate determination of the self-consumption level, temporal resolution of at least 30 s for the load profile and at least 10 min for the PV production measurements are suggested. The effect of temporal resolution be...

  6. Proposal of Xanthomonas translucens pv. pistaciae pv. nov., pathogenic to pistachio (Pistacia vera).

    Science.gov (United States)

    Giblot-Ducray, Danièle; Marefat, Alireza; Gillings, Michael R; Parkinson, Neil M; Bowman, John P; Ophel-Keller, Kathy; Taylor, Cathy; Facelli, Evelina; Scott, Eileen S

    2009-12-01

    Strains of Xanthomonas translucens have caused dieback in the Australian pistachio industry for the last 15 years. Such pathogenicity to a dicotyledonous woody host contrasts with that of other pathovars of X. translucens, which are characterized by their pathogenicity to monocotyledonous plant families. Further investigations, using DNA-DNA hybridization, gyrB gene sequencing and integron screening, were conducted to confirm the taxonomic status of the X. translucens pathogenic to pistachio. DNA-DNA hybridization provided a clear classification, at the species level, of the pistachio pathogen as a X. translucens. In the gyrB-based phylogeny, strains of the pistachio pathogen clustered among the X. translucens pathovars as two distinct lineages. Integron screening revealed that the cassette arrays of strains of the pistachio pathogen were different from those of other Xanthomonas species, and again distinguished two groups. Together with previously reported pathogenicity data, these results confirm that the pistachio pathogen is a new pathovar of X. translucens and allow hypotheses about its origin. The proposed name is Xanthomonas translucens pv. pistaciae pv. nov. PMID:19748753

  7. Large scale PV plants - also in Denmark. Project report

    Energy Technology Data Exchange (ETDEWEB)

    Ahm, P. (PA Energy, Malling (Denmark)); Vedde, J. (SiCon. Silicon and PV consulting, Birkeroed (Denmark))

    2011-04-15

    Large scale PV (LPV) plants, plants with a capacity of more than 200 kW, has since 2007 constituted an increasing share of the global PV installations. In 2009 large scale PV plants with cumulative power more that 1,3 GWp were connected to the grid. The necessary design data for LPV plants in Denmark are available or can be found, although irradiance data could be improved. There seems to be very few institutional barriers for LPV projects, but as so far no real LPV projects have been processed, these findings have to be regarded as preliminary. The fast growing number of very large scale solar thermal plants for district heating applications supports these findings. It has further been investigated, how to optimize the lay-out of LPV plants. Under the Danish irradiance conditions with several winter months with very low solar height PV installations on flat surfaces will have to balance the requirements of physical space - and cost, and the loss of electricity production due to shadowing effects. The potential for LPV plants in Denmark are found in three main categories: PV installations on flat roof of large commercial buildings, PV installations on other large scale infrastructure such as noise barriers and ground mounted PV installations. The technical potential for all three categories is found to be significant and in the range of 50 - 250 km2. In terms of energy harvest PV plants will under Danish conditions exhibit an overall efficiency of about 10 % in conversion of the energy content of the light compared to about 0,3 % for biomass. The theoretical ground area needed to produce the present annual electricity consumption of Denmark at 33-35 TWh is about 300 km2 The Danish grid codes and the electricity safety regulations mention very little about PV and nothing about LPV plants. It is expected that LPV plants will be treated similarly to big wind turbines. A number of LPV plant scenarios have been investigated in detail based on real commercial offers and

  8. The prospects for cost competitive solar PV power

    International Nuclear Information System (INIS)

    New solar Photovoltaic (PV) installations have grown globally at a rapid pace in recent years. We provide a comprehensive assessment of the cost competitiveness of this electric power source. Based on data available for the second half of 2011, we conclude that utility-scale PV installations are not yet cost competitive with fossil fuel power plants. In contrast, commercial-scale installations have already attained cost parity in the sense that the generating cost of power from solar PV is comparable to the retail electricity prices that commercial users pay, at least in certain parts of the U.S. This conclusion is shown to depend crucially on both the current federal tax subsidies for solar power and an ideal geographic location for the solar installation. Projecting recent industry trends into the future, we estimate that utility-scale solar PV facilities are on track to become cost competitive by the end of this decade. Furthermore, commercial-scale installations could reach “grid parity” in about ten years, if the current federal tax incentives for solar power were to expire at that point. - Highlights: ► Assessment of the cost competitiveness of new solar Photovoltaic (PV) installations. ► Utility-scale PV installations are not yet cost competitive with fossil fuel power plants. ► Commercial-scale installations have already attained cost parity in certain parts of the U.S. ► Utility-scale solar PV facilities are on track to become cost competitive by the end of this decade

  9. Investigation of bias radiation effect on PV cell measurement

    Science.gov (United States)

    Huang, Xuebo; Quan, Chenggen; Chan, Joanne; Ng, Patrick

    2013-06-01

    Photovoltaic (PV) cells are photo-electrical devices that convert light energy directly into electricity through the photovoltaic effect. PV cell assemblies are used to make solar modules employed in a variety of ways ranging from space applications to domestic energy consumption. Characterisation and performance testing of PV cells are critical to the development of PV technologies and growth of the solar industry. As new solar products are being developed, its energy conversion efficiency and other critical parameters must be accurately measured and tested against globally recognised metrological standards. The differential spectral responsivity (DSR) measurement is one of the primary methods for calibrating reference PV cells. This is done by calculating its spectral responsivities through measuring the AC short-circuit current produced by a PV cell under a modulated monochromatic radiation and different levels of steady-state broadband bias light radiation. It is observed that different types of bias light source will produce different signal-to-noise levels and significantly influence measurement accuracy. This paper aims to investigate the noise sources caused by different types of bias light sources (e.g. xenon arc and tungsten-halogen lamps) and the relevant measurement uncertainties so as to propose a guideline for selection of bias light source which can improve the signal-to-noise level and measurement uncertainty. The DSRs of the PV cells are measured using a commercial DSR measurement system under different levels of bias radiation from 0 to 1 kWm-2. The data analysis and uncertainty evaluation are presented in this paper using experimental data and mathematical tools.

  10. NCBI nr-aa BLAST: CBRC-XTRO-01-0707 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-0707 ref|NP_644475.1| acetate permease [Xanthomonas axonopodis pv. cit...ri str. 306] gb|AAM39011.1| solute:Na+ symporter [Xanthomonas axonopodis pv. citri str. 306] NP_644475.1 1e-136 79% ...

  11. NCBI nr-aa BLAST: CBRC-LAFR-01-1577 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-LAFR-01-1577 ref|NP_641723.1| hypothetical protein XAC1388 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM36259.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641723.1 0.077 39% ...

  12. NCBI nr-aa BLAST: CBRC-DYAK-01-0032 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DYAK-01-0032 ref|NP_640378.1| D-3-phosphoglycerate dehydrogenase [Xanthomonas ...axonopodis pv. citri str. 306] gb|AAM34914.1| D-3-phosphoglycerate dehydrogenase [Xanthomonas axonopodis pv. citri str. 306] NP_640378.1 1.1 32% ...

  13. NCBI nr-aa BLAST: CBRC-GGAL-35-0330 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-GGAL-35-0330 ref|NP_641879.1| hypothetical protein XAC1546 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM36415.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641879.1 0.034 26% ...

  14. NCBI nr-aa BLAST: CBRC-DRER-13-0011 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DRER-13-0011 ref|NP_642674.1| hypothetical protein XAC2357 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM37210.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_642674.1 5e-05 30% ...

  15. NCBI nr-aa BLAST: CBRC-PTRO-23-0017 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-PTRO-23-0017 ref|NP_642953.1| phage-related terminase [Xanthomonas axonopodis ...pv. citri str. 306] gb|AAM37489.1| phage-related terminase [Xanthomonas axonopodis pv. citri str. 306] NP_642953.1 5.6 33% ...

  16. NCBI nr-aa BLAST: CBRC-BTAU-01-1628 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-BTAU-01-1628 ref|NP_641751.1| phosphatidate cytidylyltransferase [Xanthomonas ...axonopodis pv. citri str. 306] gb|AAM36287.1| phosphatidate cytidylyltransferase [Xanthomonas axonopodis pv. citri str. 306] NP_641751.1 6.8 24% ...

  17. NCBI nr-aa BLAST: CBRC-DNOV-01-2969 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DNOV-01-2969 ref|NP_641277.1| hypothetical protein XAC0925 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM35813.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641277.1 3.0 27% ...

  18. NCBI nr-aa BLAST: CBRC-LAFR-01-1946 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-LAFR-01-1946 ref|NP_641456.1| hypothetical protein XAC1119 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM35992.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641456.1 0.50 39% ...

  19. NCBI nr-aa BLAST: CBRC-XTRO-01-0645 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-0645 ref|NP_642163.1| hypothetical protein XAC1837 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM36699.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_642163.1 9e-42 40% ...

  20. NCBI nr-aa BLAST: CBRC-DDIS-03-0106 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DDIS-03-0106 ref|NP_643514.1| hypothetical protein XAC3206 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM38050.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_643514.1 2e-31 30% ...

  1. NCBI nr-aa BLAST: CBRC-ACAR-01-0078 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-ACAR-01-0078 ref|NP_644793.1| avirulence protein [Xanthomonas axonopodis pv. c...itri str. 306] gb|AAM39311.1| avirulence protein [Xanthomonas axonopodis pv. citri str. 306] NP_644793.1 2e-04 26% ...

  2. NCBI nr-aa BLAST: CBRC-ACAR-01-0713 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-ACAR-01-0713 ref|NP_641889.1| glucose-galactose transporter [Xanthomonas axono...podis pv. citri str. 306] gb|AAM36425.1| glucose-galactose transporter [Xanthomonas axonopodis pv. citri str. 306] NP_641889.1 4.7 35% ...

  3. NCBI nr-aa BLAST: CBRC-ETEL-01-0961 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-ETEL-01-0961 ref|NP_644405.1| dipeptidyl peptidase [Xanthomonas axonopodis pv.... citri str. 306] gb|AAM38941.1| dipeptidyl peptidase [Xanthomonas axonopodis pv. citri str. 306] NP_644405.1 0.67 54% ...

  4. NCBI nr-aa BLAST: CBRC-DNOV-01-3199 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DNOV-01-3199 ref|NP_641280.1| extracellular protease [Xanthomonas axonopodis p...v. citri str. 306] gb|AAM35816.1| extracellular protease [Xanthomonas axonopodis pv. citri str. 306] NP_641280.1 5.1 25% ...

  5. NCBI nr-aa BLAST: CBRC-LAFR-01-1513 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-LAFR-01-1513 ref|NP_643310.1| MFS transporter [Xanthomonas axonopodis pv. citr...i str. 306] gb|AAM37846.1| MFS transporter [Xanthomonas axonopodis pv. citri str. 306] NP_643310.1 1.1 24% ...

  6. NCBI nr-aa BLAST: CBRC-ACAR-01-0078 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-ACAR-01-0078 ref|NP_644725.1| avirulence protein [Xanthomonas axonopodis pv. c...itri str. 306] gb|AAM39243.1| avirulence protein [Xanthomonas axonopodis pv. citri str. 306] NP_644725.1 2e-04 26% ...

  7. NCBI nr-aa BLAST: CBRC-XTRO-01-2343 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-2343 ref|NP_642141.1| filamentous haemagglutinin [Xanthomonas axonopod...is pv. citri str. 306] gb|AAM36677.1| filamentous haemagglutinin [Xanthomonas axonopodis pv. citri str. 306] NP_642141.1 6e-04 27% ...

  8. NCBI nr-aa BLAST: CBRC-LAFR-01-0106 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-LAFR-01-0106 ref|NP_643310.1| MFS transporter [Xanthomonas axonopodis pv. citr...i str. 306] gb|AAM37846.1| MFS transporter [Xanthomonas axonopodis pv. citri str. 306] NP_643310.1 0.54 26% ...

  9. NCBI nr-aa BLAST: CBRC-DRER-13-0009 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DRER-13-0009 ref|NP_642674.1| hypothetical protein XAC2357 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM37210.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_642674.1 5e-05 30% ...

  10. NCBI nr-aa BLAST: CBRC-XTRO-01-2352 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-2352 ref|NP_642468.1| YapH protein [Xanthomonas axonopodis pv. citri s...tr. 306] gb|AAM37004.1| YapH protein [Xanthomonas axonopodis pv. citri str. 306] NP_642468.1 0.30 32% ...

  11. NCBI nr-aa BLAST: CBRC-DYAK-06-0020 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DYAK-06-0020 ref|NP_642141.1| filamentous haemagglutinin [Xanthomonas axonopod...is pv. citri str. 306] gb|AAM36677.1| filamentous haemagglutinin [Xanthomonas axonopodis pv. citri str. 306] NP_642141.1 0.001 26% ...

  12. NCBI nr-aa BLAST: CBRC-BTAU-01-2358 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-BTAU-01-2358 ref|NP_641879.1| hypothetical protein XAC1546 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM36415.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641879.1 5.2 31% ...

  13. Policies and opportunities for grid parity of PV in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Lako, P.; Beurskens, L.W.M. [ECN Policy Studies, Petten (Netherlands)

    2012-01-15

    In 2010, ECN Policy Studies has provided information on the development of solar PV in the Netherlands to GlobalData, India. Based on this information request, the present note on policies and opportunities for grid parity of PV has been drafted. Recently, subsidies for solar PV in the Netherlands have shown a pattern of a roller-coaster that is typical for PV financing in a number of EU countries. Stop-and-go policies for solar PV may have multiple causes. It may be difficult to determine the right feed-in tariffs for PV; or governments may be reluctant to provide sufficient funding for a relatively expensive renewable electricity source like PV. This note sheds light on the current state of affairs and policies for PV in the Netherlands, and on several private initiatives aimed at reaching grid parity for PV which is installed by households.

  14. Durability Quality Research of Concrete Containing Solar PV Cells

    Directory of Open Access Journals (Sweden)

    Chao Sao-Jeng

    2015-01-01

    Full Text Available In this article we demonstrated the study results of durability quality of concrete containing waste solar PV cells. The study used alkali activator to improve the activity of alkali-activated materials in solar PV cells so as to replace Portland cement as binder in concrete. By using sodium hydroxide as an alkali-activator, a high-pH environment is generated to excite the binding characteristics of alkali-activated materials in solar PV cells, and thus develops better durability of the mixes. The conclusions were made on effect of this cement replacement. As a result, we identified the durability for those of 16 concrete specimens predefined and made to consider various possible control factors. The conclusions also depicted that all experiments but the drying shrinkage may be helpful with the suitable use of control factors as far as concerning the recycled solar PV cells for mixing in concrete. In other words, the durability quality of concrete may be partially unacceptable of containing solar PV cells.

  15. Design procedures of hybrid PV/SMES system

    International Nuclear Information System (INIS)

    This paper presents accurate procedures to determine the design parameters of an autonomous hybrid PV/SMES system. Integrating Superconductive magnetic energy storage as a recent storage technology with photovoltaic power system enhances the PV output utilization during the solar radiation fluctuations period. this is because of SMES fast response to any PV output fluctuation. The load demand is supplied either from PV plant or through SMES or from both. Imposed to the technical and economical constrains, the optimum solar cells area and the proper capacity and rating of SMES system are assessed. Regarding solar radiation profile, clear and cloudy days are accurately considered for investigation. Three indices are suggested to express the cloudy and fluctuations conditions. These indices represent the non-utilized PV energy due to clouds (x), fluctuation period (Tf) and location of fluctuations period(tst). The incremental changes in the design parameters are computed for any variation in these indices. Differentiation between the role of BS and SMES in affecting the results is determined and quantitatively analyzed. The results of clear day condition with SMES are the bas quantities for these changes. Complete analysis of the most effective parameters is presented. Eventually, mathematical models are deduced for each parameter which assists in predicting its behavior against the independent variable.(Author)

  16. Geographic smoothing of solar PV: results from Gujarat

    Science.gov (United States)

    Klima, Kelly; Apt, Jay

    2015-10-01

    We examine the potential for geographic smoothing of solar photovoltaic (PV) electricity generation using 13 months of observed power production from utility-scale plants in Gujarat, India. To our knowledge, this is the first published analysis of geographic smoothing of solar PV using actual generation data at high time resolution from utility-scale solar PV plants. We use geographic correlation and Fourier transform estimates of the power spectral density (PSD) to characterize the observed variability of operating solar PV plants as a function of time scale. Most plants show a spectrum that is linear in the log-log domain at high frequencies f, ranging from {f}-1.23 to {f}-1.56 (slopes of -1.23 and -1.56), thus exhibiting more relative variability at high frequencies than exhibited by wind plants. PSDs for large PV plants have a steeper slope than those for small plants, hence more smoothing at short time scales. Interconnecting 20 Gujarat plants yields a {f}-1.66 spectrum, reducing fluctuations at frequencies corresponding to 6 h and 1 h by 23% and 45%, respectively. Half of this smoothing can be obtained through connecting 4-5 plants; reaching marginal improvement of 1% per added plant occurs at 12-14 plants. The largest plant (322 MW) showed an {f}-1.76 spectrum. This suggests that in Gujarat the potential for smoothing is limited to that obtained by one large plant.

  17. Estimation of PV energy production based on satellite data

    Science.gov (United States)

    Mazurek, G.

    2015-09-01

    Photovoltaic (PV) technology is an attractive source of power for systems without connection to power grid. Because of seasonal variations of solar radiation, design of such a power system requires careful analysis in order to provide required reliability. In this paper we present results of three-year measurements of experimental PV system located in Poland and based on polycrystalline silicon module. Irradiation values calculated from results of ground measurements have been compared with data from solar radiation databases employ calculations from of satellite observations. Good convergence level of both data sources has been shown, especially during summer. When satellite data from the same time period is available, yearly and monthly production of PV energy can be calculated with 2% and 5% accuracy, respectively. However, monthly production during winter seems to be overestimated, especially in January. Results of this work may be helpful in forecasting performance of similar PV systems in Central Europe and allow to make more precise forecasts of PV system performance than based only on tables with long time averaged values.

  18. Recent Advances in PV Research and Future Directions

    Science.gov (United States)

    Deb, Satyen K.

    1998-04-01

    The photovoltaic technology is making a major thrust in the commercial arena with 1997 worldwide production of PV modules reaching over 125 MW and growing at the rate of 20-25semiconductor materials and devices are emerging as strong contenders for PV applications even though silicon is still the 'work-horse' of the industry. Ultra-high efficiency solar cells fabricated from gallium arsenide (GaAs) and its ternary alloys like gallium indium phosphide (GaInP2) are finding applications in space technology. Enormous progress has also been made on various thin-film solar cell technologies, which offer the promise for substantially reducing the cost of PV systems. Some of the leading contenders are amorphous and polycrystalline silicon, compound semiconductor thin films such as copper indium diselenide (CuInSe2) based alloys, and cadmium telluride (CdTe) thin films. Exciting new developments are happening in the use of nano-particle semiconductor materials like titanium dioxide (TiO2) for low-cost PV devices. Intense research on these and other materials and devices is making a strong impact on the technology. In this presentation, a brief overview of recent advances in PV research will b e made and the trends and opportunities for future research directions will be identified.

  19. Solar cell junction temperature measurement of PV module

    KAUST Repository

    Huang, B.J.

    2011-02-01

    The present study develops a simple non-destructive method to measure the solar cell junction temperature of PV module. The PV module was put in the environmental chamber with precise temperature control to keep the solar PV module as well as the cell junction in thermal equilibrium with the chamber. The open-circuit voltage of PV module Voc is then measured using a short pulse of solar irradiation provided by a solar simulator. Repeating the measurements at different environment temperature (40-80°C) and solar irradiation S (200-1000W/m2), the correlation between the open-circuit voltage Voc, the junction temperature Tj, and solar irradiation S is derived.The fundamental correlation of the PV module is utilized for on-site monitoring of solar cell junction temperature using the measured Voc and S at a short time instant with open circuit. The junction temperature Tj is then determined using the measured S and Voc through the fundamental correlation. The outdoor test results show that the junction temperature measured using the present method, Tjo, is more accurate. The maximum error using the average surface temperature Tave as the junction temperature is 4.8 °C underestimation; while the maximum error using the present method is 1.3 °C underestimation. © 2010 Elsevier Ltd.

  20. Modelling of flow and heat transfer in PV cooling channels

    Energy Technology Data Exchange (ETDEWEB)

    Diarra, D.C.; Harrison, S.J. [Queen' s Univ., Kingston, ON (Canada). Dept. of Mechanical and Materials Engineering Solar Calorimetry Lab; Akuffo, F.O. [Kwame Nkrumah Univ. of Science and Technology, Kumasi (Ghana). Dept. of Mechanical Engineering

    2005-07-01

    Under sunny conditions, the temperature of photovoltaic (PV) modules can be 20 to 30 degrees C above the ambient air temperature. This affects the performance of PV modules, particularly in regions with hot climates. For silicon solar cells, the maximum power decreases between 0.4 and 0.5 per cent for every degree C of temperature increase above a reference value. In an effort to address this issue, this experimental and numerical study examined an active PV panel evaporative cooling scheme that is typically used in hot arid climates. The cooling system circulated cool air behind the PV modules, extracting heat and lowering solar cell temperature. A fluid dynamic and thermal model of the combined system was developed using the EES program in order to study the configuration of the cooling channel and the characteristics of the cooling flow. Heat transfer and flow characteristics in the cooling channel were then calculated along with pressure drop and fan power associated with the air-circulation. The net power output was also calculated. The objective was to design a cost efficient cooling system and to optimize its flow and pressure drop in order to maximize power output. The study demonstrated how the performance of the PV panel is influenced by the geometry of the cooling channel, the inlet air temperature and the air flow rate. 2 refs.

  1. Modelling PV modules' performance in Sahelian climates

    Energy Technology Data Exchange (ETDEWEB)

    Diarra, D.C.; Akuffo, F.O. [Kwame Nkrumah Univ. of Science and Technology, Kumasi (Ghana). Dept. of Mechanical Engineering

    2003-08-01

    This paper describes the development of a thermo-optical model designed to evaluate the temperature of a photovoltaic (PV) module in an effort to design a cost-effective cooling system for PV modules operating under high ambient temperatures. The power output of a PV module is greatly reduced when its temperature rises. This loss in efficiency is particularly significant in Sahelian regions where PV modules are subjected to high solar radiation intensities and high ambient temperatures. The newly developed thermo-optical model confirms that most of the heat in a PV module is generated in the solar cell. The results of the analysis include: the optical absorption, reflection and transmission of the solar radiation incident on the module; the temperature distribution in the module; and, the heat transfer through the top and bottom of the module. At incidence angles of 60 degrees, approximately three-quarters of the heat is generated in the solar cell. The optical efficiency is 88.44 per cent at normal incidence angle and 82.48 per cent when the incidence angle is 60 degrees. It was determined that the cooling system should be located as close as possible to the solar cell in order to increase the thermal heat flow from the cell. 4 refs., 3 tabs., 4 figs.

  2. Thermal modelling of PV module performance under high ambient temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Diarra, D.C.; Harrison, S.J. [Queen' s Univ., Kingston, ON (Canada). Dept. of Mechanical and Materials Engineering Solar Calorimetry Lab; Akuffo, F.O. [Kwame Nkrumah Univ. of Science and Technology, Kumasi (Ghana). Dept. of Mechanical Engineering

    2005-07-01

    When predicting the performance of photovoltaic (PV) generators, the actual performance is typically lower than test results conducted under standard test conditions because the radiant energy absorbed in the module under normal operation raises the temperature of the cell and other multilayer components. The increase in temperature translates to a lower conversion efficiency of the solar cells. In order to address these discrepancies, a thermal model of a characteristic PV module was developed to assess and predict its performance under real field-conditions. The PV module consisted of monocrystalline silicon cells in EVA between a glass cover and a tedlar backing sheet. The EES program was used to compute the equilibrium temperature profile in the PV module. It was shown that heat is dissipated towards the bottom and the top of the module, and that its temperature can be much higher than the ambient temperature. Modelling results indicate that 70-75 per cent of the absorbed solar radiation is dissipated from the solar cells as heat, while 4.7 per cent of the solar energy is absorbed in the glass cover and the EVA. It was also shown that the operating temperature of the PV module decreases with increased wind speed. 2 refs.

  3. Design of direct solar PV driven air conditioner

    KAUST Repository

    Huang, Bin-Juine

    2015-12-05

    © 2015 Elsevier Ltd. Solar air conditioning system directly driven by stand-alone solar PV is studied. The air conditioning system will suffer from loss of power if the solar PV power generation is not high enough. It requires a proper system design to match the power consumption of air conditioning system with a proper PV size. Six solar air conditioners with different sizes of PV panel and air conditioners were built and tested outdoors to experimentally investigate the running probabilities of air conditioning at various solar irradiations. It is shown that the instantaneous operation probability (OPB) and the runtime fraction (RF) of the air conditioner are mainly affected by the design parameter rpL (ratio of maximum PV power to load power). The measured OPB is found to be greater than 0.98 at instantaneous solar irradiation IT > 600 W m-2 if rpL > 1.71 RF approaches 1.0 (the air conditioner is run in 100% with solar power) at daily-total solar radiation higher than 13 MJ m-2 day-1, if rpL > 3.

  4. Interline Photovoltaic (I-PV) power system - A novel concept of power flow control and management

    OpenAIRE

    Khadkikar, Vinod; Kirtley, James L., Jr.

    2011-01-01

    This paper presents a new system configuration for a large-scale Photovoltaic (PV) power system with multi-line transmission/distribution networks. A PV power plant is reconfigured in a way that two adjacent power system networks/ feeders can be interconnected. The inverter modules in a PV power plant are configured such that the system is represented as a back to back inverter connected multi-line system, called as Interline-PV (I-PV) system. The proposed I-PV system then can be controlled a...

  5. The world PV market 2000: shifting from subsidy to 'fully economic'?

    International Nuclear Information System (INIS)

    This article presents an overview of the world grid-connected photovoltaic (PV) market concentrating on the US, Japan and Germany. The PV markets in the three countries are examined, and PV module shipments, the economics of residential PVs in the markets, and forecasts of the grid-connected market are discussed. Details are given of the German 100,000 roofs PV roof subsidy programme to stimulate the residential and commercial grid-connected market. A summary of the grid-connected PV markets in the three countries, and economic information on German grid-connected PV roofs are tabulated

  6. Z - Source Multi Level Inverter Based PV Generation System

    Directory of Open Access Journals (Sweden)

    T. Lakhmi kanth

    2014-09-01

    Full Text Available In this paper a novel technique of Z-Source multilevel Inverter based PV Generation system is implemented and simulated using MATLAB-Simulink simulation software. The Photovoltaic cells are healthier option for converting solar energy into electricity. Due to high capital cost and low efficiency PV cells have not yet been a fully smart choice for electricity users. To enhance the performance of the system, Z-Source multi level inverter can be used in place of conventional Voltage Source Inverter (VSI in Solar Power Generation System. The PV cell model is developed using circuit mathematical equations. The Z-Source multilevel inverter is modeled to realize boosted DC to AC conversion (inversion with low THD. Outcome shows that the energy conversion efficiency of ZSMLI is a lot improved as compared to conventional voltage Source Inverter (VSI. By doing FFT analysis we can know the total THD.

  7. Disposal and recycling of end-of-life PV modules

    International Nuclear Information System (INIS)

    Recycling can be a cost-effective way to dispose of end-of-life PV modules. Recycling is likely economic if key components (e.g., Si wafers and/or glass sheets) can be salvaged intact, or the modules are classified as hazardous under existing environmental regulations. End-of-life PV modules based on thin-film CuInSe2, thin-film CdTe, amorphous silicon and crystalline silicon will likely not be classified as hazardous under existing US national regulations; but further testing is required. End-of-life CuInSe2, CdTe and crystalline Si PV modules may all be classified as hazardous under more-restrictive state regulations, e.g., in California., In every case, recycling can simplify handling and disposal of end-of-life modules

  8. Solar PV energy for rural development in Balochistan

    International Nuclear Information System (INIS)

    Province Balochistan is largest province of Pakistan with smallest density of population with little or no development. In Balochistan bulk is rural located and devoid of lives basic ingredients. In remote rural areas of Balochistan because of high cost and problems associated with grid extension or diesel power generation, solar electricity is viable alternate. Energy generated from the sun is world's most abundant and in-exhaustible source of energy PV cells sun light is converted directly in to electricity called solar PV energy. Solar energy through photovoltaic cells can be tapped to supply electricity to remote rural areas of Balochistan. In this paper author has examined the problems in more detail, showing by simple calculation of cost economics that solar PV systems are viable. (author)

  9. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Weng, Dean [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefi t the industry at-large.

  10. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Weng, Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefit the industry at-large.

  11. Models for a stand-alone PV system

    DEFF Research Database (Denmark)

    Hansen, A.D.; Sørensen, Poul Ejnar; Hansen, L.H.;

    2001-01-01

    This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risø National Laboratory. The work has been supported by the Danish Ministry ofEnergy, as a part of the activities in the Solar...... Energy Centre Denmark. The study is carried out at Risø National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PVsystem, namely solar cells, battery, controller, inverter and load. The models for PV module and battery....... The performance of the best linear Blackbox model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risø....

  12. Lessons Learned from the Photovoltaic Manufacturing Technology/PV Manufacturing R&D and Thin Film PV Partnership Projects

    Energy Technology Data Exchange (ETDEWEB)

    Margolis, R.; Mitchell, R.; Zweibel, K.

    2006-09-01

    As the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program initiates new cost-shared solar energy R&D under the Solar America Initiative (SAI), it is useful to analyze the experience gained from cost-shared R&D projects that have been funded through the program to date. This report summarizes lessons learned from two DOE-sponsored photovoltaic (PV) projects: the Photovoltaic Manufacturing Technology/PV Manufacturing R&D (PVMaT/PVMR&D) project and the Thin-Film PV Partnership project. During the past 10-15 years, these two projects have invested roughly $330 million of government resources in cost-shared R&D and leveraged another $190 million in private-sector PV R&D investments. Following a description of key findings and brief descriptions of the PVMaT/PVMR&D and Thin-Film PV Partnership projects, this report presents lessons learned from the projects.

  13. Time series power flow analysis for distribution connected PV generation.

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J. [Georgia Institute of Technology, Atlanta, GA; Smith, Jeff [Electric Power Research Institute, Knoxville, TN; Dugan, Roger [Electric Power Research Institute, Knoxville, TN

    2013-01-01

    Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating

  14. Industrial application of PV/T solar energy systems

    International Nuclear Information System (INIS)

    Hybrid photovoltaic/thermal (PV/T) systems consist of PV modules and heat extraction units mounted together. These systems can simultaneously provide electrical and thermal energy, thus achieving a higher energy conversion rate of the absorbed solar radiation than plain photovoltaics. Industries show high demand of energy for both heat and electricity and the hybrid PV/T systems could be used in order to meet this requirement. In this paper the application aspects in the industry of PV/T systems with water heat extraction is presented. The systems are analyzed with TRNSYS program for three locations Nicosia, Athens and Madison that are located at different latitudes. The system comprises 300 m2 of hybrid PV/T collectors producing both electricity and thermal energy and a 10 m3 water storage tank. The work includes the study of an industrial process heat system operated at two load supply temperatures of 60 deg. C and 80 deg. C. The results show that the electrical production of the system, employing polycrystalline solar cells, is more than the amorphous ones but the solar thermal contribution is slightly lower. A non-hybrid PV system produces about 25% more electrical energy but the present system covers also, depending on the location, a large percentage of the thermal energy requirement of the industry considered. The economic viability of the systems is proven, as positive life cycle savings are obtained in the case of hybrid systems and the savings are increased for higher load temperature applications. Additionally, although amorphous silicon panels are much less efficient than the polycrystalline ones, better economic figures are obtained due to their lower initial cost, i.e., they have better cost/benefit ratio

  15. Energy investments and production costs of amorphous silicon PV modules

    Energy Technology Data Exchange (ETDEWEB)

    Srinivas, K.S. (Neuchatel Univ., Inst. de Microtechnique, Neuchatel (Switzerland))

    1991-10-01

    Viability of large scale applications of photovoltaic technology will ultimately depend upon the economics of energy payback and production costs associated with it. For the potential options among the various PV technologies this aspect has been analysed to a considerable extent for crystalline silicon (mono- and poly-) modules. No systematic study, based on practical aspects of A-Si PV module production has yet been reported. In this study the energy investments and production costs of A-Si PV module production have been analysed based on factual data from two manufacturing units. Each process step involved in the manufacture of A-Si modules is analysed for the process electrical energy and the hidden energy content in the various materials associated with that step. Energy payback period and the production costs have been calculated on the basis of prevailing levels of conversion efficiency (5%) and production yield ([approx equal]80%). The report also covers salient features of A-Si technology, the current status of PV industry in respect of production, R+D and cost status of competing PV technologies. A review of earlier studies on energy investments and production costs of A-Si modules and a comparison of their findings with that of the present study are also discussed. Certain details which could not be included in the main text to maintain the continuity of thoughts, are presented as annexes. A short note on 'criteria for choice of technology for large scale PV production' and a brief description of the status of other thin-film technologies (CIS,CdTe) are included as Appendices at the end. figs., tabs., 18 refs.

  16. Modular Power Converters for PV Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL

    2012-05-01

    This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need

  17. Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

    2012-04-01

    Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

  18. Clear sky pure water - PV water pumping and desalination

    International Nuclear Information System (INIS)

    Providing adequate portable drinking water is becoming a serious problem in remote areas. Saudi Arabia is a very suitable place to use renewable energy such as photovoltaic (PV) energy. For this reason, a PV system was designed and installed along with water pumping and desalination systems in the village of Sadous, about 72 km from Riyadh. The total number of panels is 158, and they give 11.06 kW. The average pumped water from the well is about 18 m3/day with total dissolved solids (TDS) greater than 6000 PPM. The average product water is about 5 m3/day with TDS less than 300 PPM. (Author)

  19. Design and Implementation of A PV Powered Tri-Cycle

    Directory of Open Access Journals (Sweden)

    Soumya Das

    2016-04-01

    Full Text Available Solar PV technology is one of the first among the various renewable energy technologies that have been adopted and accepted universally in order to meet the basic needs of generation of electricity. The objective of this paper is to propose a tri-cycle that utilises the application of stand-alone photovoltaic (PV system. A preliminary design and construction of a solar tri-cycle has been performed by evaluating and estimating the required panel size, battery capacity and motor power. Calculation in this paper exhibit that the solar power alone will be sufficient to operate a tri-cycle from one place to another.

  20. Review of Solar PV Market Development in East Africa

    OpenAIRE

    Hansen, Ulrich Elmer; Pedersen, Mathilde Brix; Nygaard, Ivan

    2014-01-01

    While the diffusion of solar home systems in Kenya has been market-based for some years, the diffusion of PV in most other Sub-Saharan African countries has been driven by government and donor-supported projects aimed at serving specific needs for electricity while at the same time creating a national niche market for PV. This practice is rapidly changing and, as in industrialised countries, there is evidence of a transition towards more market-based diffusion and private-sector involvement f...

  1. High Efficient Bidirectional Battery Converter for residential PV Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Kerekes, Tamas; Teodorescu, Remus

    2012-01-01

    Photovoltaic (PV) installation is suited for the residential environment and the generation pattern follows the distribution of residential power consumption in daylight hours. In the cases of unbalance between generation and demand, the Smart PV with its battery storage can absorb or inject the...... power to balance it. High efficient bidirectional converter for the battery storage is required due high system cost and because the power is processed twice. A 1.5kW prototype is designed and built with CoolMOS and SiC diodes, >;95% efficiency has been obtained with 200 kHz hard switching....

  2. PV cell and module performance measurement capabilities at NREL

    Energy Technology Data Exchange (ETDEWEB)

    Rummel, S.; Emery, K.; Field, H.; Moriarty, T.; Anderberg, A.; Dunlavy, D.; Ottoson, L.

    1998-09-01

    The Photovoltaic (PV) Cell and Module Performance Characterization team at NREL supports the entire photovoltaic community by providing: secondary calibrations of photovoltaic cells and modules; efficiency measurements with respect to a given set of standard reporting conditions; verification of contract efficiency milestones; and current versus voltage (I-V) measurements under various conditions of temperature, spectral irradiance, and total irradiance. Support is also provided to in-house programs in device fabrication, module stability, module reliability, PV systems evaluations, and alternative rating methods by performing baseline testing, specialized measurements and other assistance when required. The I-V and spectral responsivity equipment used to accomplish these tasks are described in this paper.

  3. A Comparative Life Cycle Assessment of PV Solar Systems

    OpenAIRE

    Bekkelund, Kristine

    2013-01-01

    In this report, a comparative life cycle assessment (LCA) of a rooftop, grid-connected photovoltaic (PV) system has been conducted. The primary objective has been to assess the environmental impacts resulting from the PV system over its entire lifetime, while the secondary goal has been to perform a sensitivity analysis on selected parameters and compare the results with the impacts from wind power. Four different cases have been assessed: Mc-Si Sim, mc-Si ESS, CdTe and CIGS. The difference b...

  4. Quantifying PV module microclimates and translation into accelerated weathering protocols

    Science.gov (United States)

    Phillips, Nancy H.; Scott, Kurt P.

    2014-10-01

    Long term reliability is not well addressed by current standards for PV modules or components, and developing accelerated weathering stress protocols to test the resistance of key components to wear-out is an active area of research. A first step is to understand and quantify the range of actual stresses modules will encounter in the various mounting configurations and in-service environments. In this paper, we use real-world data to benchmark PV module service environments in hot/dry, hot/wet, and temperate environments, with subsequent analysis to translate the microclimate data into a portfolio of practical weathering instrument settings.

  5. PV domestic field trial. Third annual technical report

    Energy Technology Data Exchange (ETDEWEB)

    Crick, F.; Davies, N.; Munzinger, M.; Pearsall, N.; Martin, C.

    2004-07-01

    This report summaries the results of a field trials investigating the design, construction and operation of photovoltaic (PV) systems installed during 2003 to provide information for utilities, building developers and those involved in PV installations and operations. Topics examined include the appearance of the systems, their architectural integration, the different fixing methods, the cost effectiveness of the systems, problems encountered, and monitoring activities. Key issues discussed include communication and co-ordination between interested bodies, siting and location, and good practice. Details are given of monitoring inspection visits, and performance analysis.

  6. Light filtering by epidermal flavonoids during the resistant response of cotton to Xanthomonas protects leaf tissue from light-dependent phytoalexin toxicity

    Science.gov (United States)

    2,7-Dihydroxycadalene and lacinilene C, sesquiterpenoid phytoalexins that accumulate at infection sites during the hypersensitive resistant response of cotton foliage to Xanthomonas campestris pv. malvacearum, have light-dependent toxicity toward host cells, as well as toward the bacterial pathogen....

  7. Task 9. PV deployment in developing countries. Institutional framework and financial instruments for PV deployment in developing countries

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-09-15

    This report for the International Energy Agency (IEA) made by Task 9 of the Photovoltaic Power Systems (PVPS) programme takes a look at the institutional framework and financial instruments necessary for PV deployment in developing countries. This guide describes the institutional and financial aspects that need to be addressed to ensure that a long term sustainable (and profitable) PV market is established in developing countries. The guide details main fundamental functions that need to be performed such as the agents needed to perform the functions and their differing roles within the framework, the relationships between these agents and the financial instruments available. It is stated that the majority of the aspects recommended in this guide can be adopted to two main PV deployment models: direct sales and rural electrification and development programmes. It is noted that both approaches will have to be tailored and adapted to local conditions.

  8. PV solar electricity industry: Market growth and perspective

    International Nuclear Information System (INIS)

    The photovoltaic (PV) solar electricity market has shown an impressive 33% growth per year since 1997 until today with market support programs as the main driving force. The rationales for this development and the future projections towards a 100 billion | industry in the 2020s, by then only driven by serving cost-competitively customer needs are described. The PV market, likely to have reached about 600MW in the year 2003, is discussed according to its four major segments: consumer applications, remote industrial electrification, developing countries, and grid-connected systems. While in the past, consumer products and remote industrial applications used to be the main cause for turnover in PV, in recent years the driving forces are more pronounced in the grid-connected systems and by installations in developing countries. Examples illustrating the clear advantage of systems using PV over conventional systems based, e.g., on diesel generators in the rural and remote electrification sector are discussed. For the promotion of rural electrification combined with the creation of local business and employment, suitable measures are proposed in the context of the PV product value chain. The competitiveness of grid-connected systems is addressed, where electricity generating costs for PV are projected to start to compete with conventional utility peak power quite early between 2010 and 2020 if time-dependent electricity tariffs different for bulk and peak power are assumed. The most effective current-pulling force for grid-connected systems is found to be the German Renewable Energy (EEG) Feed-in Law where the customers are focusing on yield, performance, and long-life availability. The future growth in the above-defined four market segments are discussed and the importance of industry political actions in order to stimulate the markets either in grid-connected systems by feed-in tariff programs as well as for off-grid rural developing country applications by long

  9. Comparison of three different methods of perturbing the potential vorticity field in mesoscale forecasts of Mediterranean heavy precipitation events: PV-gradient, PV-adjoint and PV-satellite

    Science.gov (United States)

    Vich, M.; Romero, R.; Richard, E.; Arbogast, P.; Maynard, K.

    2010-09-01

    Heavy precipitation events occur regularly in the western Mediterranean region. These events often have a high impact on the society due to economic and personal losses. The improvement of the mesoscale numerical forecasts of these events can be used to prevent or minimize their impact on the society. In previous studies, two ensemble prediction systems (EPSs) based on perturbing the model initial and boundary conditions were developed and tested for a collection of high-impact MEDEX cyclonic episodes. These EPSs perturb the initial and boundary potential vorticity (PV) field through a PV inversion algorithm. This technique ensures modifications of all the meteorological fields without compromising the mass-wind balance. One EPS introduces the perturbations along the zones of the three-dimensional PV structure presenting the local most intense values and gradients of the field (a semi-objective choice, PV-gradient), while the other perturbs the PV field over the MM5 adjoint model calculated sensitivity zones (an objective method, PV-adjoint). The PV perturbations are set from a PV error climatology (PVEC) that characterizes typical PV errors in the ECMWF forecasts, both in intensity and displacement. This intensity and displacement perturbation of the PV field is chosen randomly, while its location is given by the perturbation zones defined in each ensemble generation method. Encouraged by the good results obtained by these two EPSs that perturb the PV field, a new approach based on a manual perturbation of the PV field has been tested and compared with the previous results. This technique uses the satellite water vapor (WV) observations to guide the correction of initial PV structures. The correction of the PV field intents to improve the match between the PV distribution and the WV image, taking advantage of the relation between dark and bright features of WV images and PV anomalies, under some assumptions. Afterwards, the PV inversion algorithm is applied to run

  10. Hospedeiros alternativos de Xanthomonas campestris pv. viticola Alternative hosts of Xanthomonas campestris pv. viticola

    Directory of Open Access Journals (Sweden)

    Ana Rosa Peixoto

    2007-04-01

    Full Text Available Xanthomonas campestris pv. viticola (Xcv, que causa o cancro bacteriano da videira, sobrevive em plantas infectadas, epifiticamente em órgãos da parte aérea e pode ser veiculada em mudas e/ou bacelos infectados. O trabalho teve como objetivo investigar possíveis hospedeiros alternativos do patógeno, visando fornecer subsídios para o manejo da doença. A partir das plantas invasoras Alternanthera tenella, Amaranthus sp., Glycine sp. e Senna obtusifolia com sintomas similares aos do cancro bacteriano da videira, coletadas em parreirais de Juazeiro e Petrolina, no Submédio São Francisco, foram isoladas bactérias semelhantes a Xcv. No entanto, nenhuma bactéria foi isolada de plantas de Commelina benghalensis e Azadirachta indica com sintomas semelhantes. A patogenicidade dos isolados bacterianos obtidos foi confirmada em plantas de A. tenella, Amaranthus sp., Glycine sp., S. obtusifolia e em mudas de videira cv. Red Globe, em condições de casa de vegetação. As plantas invasoras Chamaesyce hirta, Dactyloctenium aegyptium, Eragrostis pilosa e Pilea sp., inoculadas artificialmente com os isolados Xcv1 e UnB1216, também desenvolveram sintomas típicos do cancro bacteriano.Xanthomonas campestris pv. viticola (Xcv, which causes the bacterial canker of grapevine, survives in infected plants as an epiphyte on aerial plant parts and may be carried in infected transplants and/or cuttings. This study was performed to investigate putative alternative hosts of the pathogen, aiming to find support for disease management. Bacteria similar to Xcv were isolated from the weeds Alternanthera tenella, Amaranthus sp., Glycine sp. and Senna obtusifolia showing canker-like symptoms and collected in vineyards of Juazeiro and Petrolina at the Submédio São Francisco. No bacteria were isolated from Commelina benghalensis and Azadirachta indica showing similar symptoms. The pathogenicity of the isolates was confirmed in plants of A. tenella, Amaranthus sp

  11. Draft genome sequences of five Pseudomonas syringae pv. actinidifoliorum strains isolated in France.

    Science.gov (United States)

    Cunty, Amandine; Cesbron, Sophie; Briand, Martial; Carrère, Sébastien; Poliakoff, Françoise; Jacques, Marie-Agnès; Manceau, Charles

    2016-01-01

    Pseudomonas syringae pv. actinidifoliorum causes necrotic spots on the leaves of Actinidia deliciosa and Actinidia chinensis. P. syringae pv. actinidifoliorum has been detected in New Zealand, Australia, France and Spain. Four lineages were previously identified within the P. syringae pv. actinidifoliorum species group. Here, we report the draft genome sequences of five strains of P. syringae pv. actinidifoliorum representative of lineages 1, 2 and 4, isolated in France. The whole genomes of strains isolated in New Zealand, representative of P. syringae pv. actinidifoliorum lineages 1 and 3, were previously sequenced. The availability of supplementary P. syringae pv. actinidifoliorum genome sequences will be useful for developing molecular tools for pathogen detection and for performing comparative genomic analyses to study the relationship between P. syringae pv. actinidifoliorum and other kiwifruit pathogens, such as P. syringae pv. actinidiae. PMID:27237113

  12. Dynamic Model Validation of PV Inverters Under Short-Circuit Conditions: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Singh, M.; Bravo, R.; Gevorgian, V.

    2013-03-01

    Photovoltaic (PV) modules have dramatically decreased in price in the past few years, spurring the expansion of photovoltaic deployment. Residential and commercial rooftop installations are connected to the distribution network; large-scale installation PV power plants (PVPs) have benefited from tax incentives and the low cost of PV modules. As the level penetration of PV generation increases, the impact on power system reliability will also be greater. Utility power system planners must consider the role of PV generation in power systems more realistically by representing PV generation in dynamic stability analyses. Dynamic models of PV inverters have been developed in the positive sequence representation. NREL has developed a PV inverter dynamic model in PSCAD/EMTDC. This paper validates the dynamic model with an actual hardware bench test conducted by Southern California Edison's Distributed Energy Resources laboratory. All the fault combinations -- symmetrical and unsymmetrical -- were performed in the laboratory. We compare the simulation results with the bench test results.

  13. Voltage rise mitigation for solar PV integration at LV grids:Studies from PVNET. dk

    OpenAIRE

    Yang, Guangya; Marra, Francesco; Juamperez Goñi, Miguel Angel; Kjaer, Søren Bækhøj; Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Hans Henrik, Ipsen; Kenn H. B., Frederiksen

    2015-01-01

    Solar energy from photovoltaic (PV) is among the fastest developing renewable energy systems worldwide. Driven by governmental subsidies and technological development, Europe has seen a fast expansion of solar PV in the last few years. Among the installed PV plants, most of them are situated at the distribution systems and bring various operational challenges such as power quality and power flow management. The paper discusses the modelling requirements for PV system integration studies, as w...

  14. Comparison of the indoor performance of 12 commercial PV products by a simple model

    OpenAIRE

    Apostolou, G; Reinders, A.H.M.E.; Verwaal, M.

    2016-01-01

    This article presents a simple comparative model which has been developed for the estimation of the performance of photovoltaic (PV) products' cells in indoor environments. The model predicts the performance of PV solar cells, as a function of the distance from a spectrum of artificial (fluorescent light, halogen light, and light-emitting diodes) and natural light. It intends to support designers, while creating PV-integrated products for indoor use. For the model's validation, PV cells of 12...

  15. PV-θ view of the zonal mean state of the atmosphere

    Directory of Open Access Journals (Sweden)

    Aarnout J. Van Delden

    2012-08-01

    Full Text Available The relation between zonal mean potential vorticity (PV in potential temperature (θ coordinates and the zonal mean zonal wind in January and in July is studied. PV-anomalies are defined with respect to a reference state that is at rest with respect to the rotating earth. Two important PV-anomalies are identified. One PV-anomaly, the ‘Ex-UTLS PV-anomaly’, coincides approximately with the extratropical tropopause (310–360 K. It is a permanent feature of the zonal mean state. The other PV-anomaly is located higher in the stratosphere. It exhibits a strong seasonal cycle, i.e. in winter, it is strongly positive, while in summer, it is weakly negative. In the Northern Hemisphere winter, the Ex-UTLS PV-anomaly and the stratospheric PV-anomaly are separated by a ‘surf-zone’, which is characterised by a negative PV-anomaly pole-wards of a positive PV-anomaly. Piecewise PV-inversion reveals that (1 the Ex-UTLS PV-anomaly induces the westerly winds in the troposphere and the lower stratosphere, including the subtropical jet, that (2 the positive stratospheric PV-anomaly induces the stratospheric polar night jet and that (3 the negative polar cap stratospheric PV-anomaly in summer reduces the westerly wind speeds in the troposphere and induces easterly winds in the stratosphere. The Ex-UTLS PV-anomaly is manifest mainly as an isentropic density- (or mass- anomaly. Piecewise PV-inversion of these anomalies in isolation should account for this by an appropriate adjustment of the lower boundary condition.

  16. An Improved Matlab-Simulink Model of PV Module considering Ambient Conditions

    OpenAIRE

    2014-01-01

    A photovoltaic (PV) model is proposed on Matlab/Simulink environment considering the real atmospheric conditions and this PV model is tested with different PV panels technologies (monocrystalline silicon, polycrystalline silicon, and thin film). The meteorological data of Istanbul—the location of the study—such as irradiance, cell temperature, and wind speed are taken into account in the proposed model for each technology. Eventually, the power outputs of the PV module under real atmospheric ...

  17. Comparing critical success factors for PV between three regions

    International Nuclear Information System (INIS)

    As a research method the project team has chosen to survey the opinion of PV experts and persons involved in the implementation of PV. Therefore, a questionnaire was sent to about 300 persons spread among 3 regions America, Europe and Asia. The returned questionnaires have been statistical analysed with the software tool SPSS. The used analytical methods can be divided in a comparing method (Mann-Whitney test) and ranking methods (Friedman test and the medal classification test). General conclusions are that there is a significant difference in answers between America and Europe about the significance of 'cost reduction'. Also Asia is significant different from America and Europe for the factor 'technical' reliability. There is a significant difference about the status of financing between America and Europe versus Asia. All the regions have a different opinion about the status of RD and D'. Also the status of 'the PV network' is significant different between Asia and America. America and Europe rank 'financial aspects' and 'cost reduction' as the most significant aspects while Asia rank 'specialist knowledge' and 'the PV network' as the most significant. All regions rank 'specialist knowledge' having the worst status and rank 'environmental merits' and 'technical reliability' having the best status. Finally Europe and Asia differ significant about which aspect is the most important for the factors 'internationalisation and other activities'. Europe finds 'harmonisation of policy' the most important internationalisation aspect and Asia prefers 'development aid'. Asia prefers 'pioneering activities' and Europe prefers 'initiatives by social organisations' as most important other activity. (au)

  18. Performance enhancement of PV cells through micro-channel cooling

    Directory of Open Access Journals (Sweden)

    Muzaffar Ali

    2015-11-01

    Full Text Available Efficiency of a PV cell is strongly dependent on its surface temperature. The current study is focused to achieve maximum efficiency of PV cells even in scorching temperatures in hot climates like Pakistan where the cell surface temperatures can even rise up to around 80 ℃. The study includes both the CFD and real time experimental investigations of a solar panel using micro channel cooling. Initially, CFD analysis is performed by developing a 3D model of a Mono-Crystalline cell with micro-channels to analyze cell surface temperature distribution at different irradiance and water flow rates. Afterwards, an experimental setup is developed for performance investigations under the real conditions of an open climate of a Pakistan's city, Taxila. Two 35W panels are manufactured for the experiments; one is based on the standard manufacturing procedure while other cell is developed with 4mm thick aluminum sheet having micro-channels of cross-section of 1mm by 1mm. The whole setup also includes different sensors for the measurement of solar irradiance, cell power, surface temperature and water flow rates. The experimental results show that PV cell surface temperature drop of around 15 ℃ is achieved with power increment of around 14% at maximum applied water flow rate of 3 LPM. Additionally, a good agreement is also found between CFD and experimental results. Therefore, that study clearly shows that a significant performance improvement of PV cells can be achieved through the proposed cell cooling technique.

  19. Tools for PV (photovoltaic) plant operators: Nowcasting of passing clouds

    Czech Academy of Sciences Publication Activity Database

    Paulescu, M.; Badescu, V.; Brabec, Marek

    2013-01-01

    Roč. 54, č. 1 (2013), s. 104-112. ISSN 0360-5442 R&D Projects: GA MŠk LD12009 Institutional support: RVO:67985807 Keywords : PV ( photovoltaic ) plants * Sunshine number * Nowcasting * ARIMA (Autoregressive Integrated Moving Average) modeling Subject RIV: JE - Non-nuclear Energetics, Energy Consumption ; Use Impact factor: 4.159, year: 2013

  20. The German experience with grid-connected PV-systems

    International Nuclear Information System (INIS)

    Grid-connected photovoltaics experienced increasing attention in Germany in recent years and are expected to face a major boost at the beginning of the new millennium. Highlights like the German 100,000-Roofs-Solar-Programme, PV programmes at schools financed by utilities and governments (e.g. 'SONNEonline' by PreussenElektra, 'Sonne in der Schule' by BMWi and 'Sonne in der Schule' by Bayernwerk) and large centralised installations of MW size ('Neue Messe Munchen' by Bayernwerk and 'Energiepark Mont-Cenis' by state Nordrhein-Westfalen, Stadtwerke Herne and European Union) count for the potential of grid-connected PV. Today in Germany a typical grid-connected PV installation of 1 kW nominal power produces average annual energy yields of 700 kWh (dependent on location and system components) and shows a high operating availability. The price per kWh from PV installations is still significantly higher than the price for conventional energy, but new funding schemes and cost models (like the large increase of feed-in tariff in Germany due to the Act on Granting Priority to Renewable Energy Sources in 2000) give optimism about the future. (Author)

  1. Environmental impacts of PV systems -- Ground-based vs BIPV

    International Nuclear Information System (INIS)

    This study is part of the ExternE program of the European Commission on the external costs of the photovoltaic (PV) fuel cycle. The objective of this paper is the quantitative evaluation of the main environmental impacts of two selected PV systems--the ground-based 1MWp system in Toledo, Spain and the 40 kWp building integrated facade in Newcastle upon Tyne, NE England, using the methodology of life cycle analysis (LCA). Both systems use silicon wafer technology at present, but the Newcastle facade was also studied with the incorporation CdTe modules. The results of the LCA show that atmospheric emissions are the priority impacts with respect to the assessed PV systems. Comparing Si wafer systems, the CO2 emissions were 88 t/GWh for the Toledo PV plant and 143t/GWh for the BIPV facade. If the facade had used electrodeposited CdTe, the CO2 emissions would fall to about 50t/GWh

  2. DISTRIBUTION FEEDER PROTECTION WITH AND WITHOUT PV SYSTEM

    OpenAIRE

    PADMAVATHY.P, PARTHASARATHY.S

    2013-01-01

    This paper deals with the enhanced fault analysis methodology enabling protection engineers to design a distribution protective system. This paper also deals with the determination of operating time of the protective devices on distribution feeder with and without photovoltaic systems along with the computation of fault current and its variation on using photovoltaic (PV) system.

  3. Recent advances in PV systems technology development in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Imamura, M.; Grottke, M.; Weiss, I. [WIP Renewable Energies Division, Munich (Germany)

    1995-11-01

    The objectives of the photovoltaics (PV) systems technology development were to study several aspects of plant design, monitoring, control, operation, and management of different types of photovoltaic plants. Unsolved problems were to be identified and analysed, and guidelines to improve the monitoring system were to be developed. Principal studies are summarized.

  4. Opportunities and Challenges for Power Electronics in PV Modules (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Deline, C.; Wohlgemuth, J.; Marion, B.; Granata, J.

    2011-02-01

    The presentation describes the value of adding DC converters and other power electronics to modules to improve their output even when shading or bad cells would otherwise decrease the module output. The presentation was part of a workshop sponsored by ARPA-E exploring the opportunities for power electronics to support PV applications.

  5. PV Systems Reliability Final Technical Report: Ground Fault Detection

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    We have examined ground faults in PhotoVoltaic (PV) arrays and the efficacy of fuse, current detection (RCD), current sense monitoring/relays (CSM), isolation/insulation (Riso) monitoring, and Ground Fault Detection and Isolation (GFID) using simulations based on a Simulation Program with Integrated Circuit Emphasis SPICE ground fault circuit model, experimental ground faults installed on real arrays, and theoretical equations.

  6. Selecting Solar. Insights into Residential Photovoltaic (PV) Quote Variation

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    This analysis leverages available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  7. PV industry growth and module reliability in Thailand

    Science.gov (United States)

    Chenvidhya, Dhirayut; Seapan, Manit; Sangpongsanont, Yaowanee; Chenvidhya, Tanokkorn; Limsakul, Chamnan; Songprakorp, Roongrojana

    2015-09-01

    The PV applications in Thailand are now installed more than 1.2 GWp cumulatively. It is due to the National Renewable Energy Program and its targets. In the latest Alternative Energy Development Plan (AEDP), the PV electricity production target has increased from 2 GWp to 3 GWp. With this rapid growth, customers and manufacturers seek for module standard testing. So far over one thousands of PV modules per annum have been tested since 2012. The normal tests include type approval test according to TIS standard, acceptance test and testing for local standard development. For type test, the most module failure was found during damp heat test. For annual evaluation test, the power degradation and delamination of power was found between 0 to 6 percent from its nameplate after deployment of 0 to 5 years in the field. For thin-film module, the degradation and delamination was found in range of 0 to 13 percent (about 5 percent on average) from its nameplate for the modules in operation with less than 5 years. However, for the PV modules at the reference site on campus operated for 12 years, the power degradation was ranging from 10 to 15 percent. Therefore, a long term performance assessment needs to be considered to ensure the system reliability.

  8. Detection of Pseudomonas savastanoi pv. glycinea in soybean seeds

    Science.gov (United States)

    This chapter is one of 52 that will compose the second edition of the Laboratory Manual for the Detection of Plant Pathogenic Bacteria from Seeds and other Planting Material, to be published by the American Phytopathological Society. The chapter presents a description of Pseudomonas savastanoi pv. ...

  9. ECO-TOURISM SUSTAINABILITY THROUGH PV TECHNOLOGY: A COMPREHENSIVE REVIEW

    Directory of Open Access Journals (Sweden)

    ARAVIND C. V

    2013-12-01

    Full Text Available Through the Economic Transformation program the Malaysian Government aims to consider tourism as one of the major contributors to the country’s economy and as an industry that imbibe on the principles of environmental responsibility and sustainable development. The growing challenges in the prevention of expansion in agriculture, forestry and aquaculture, and over-exploitation of the natural resources, have made ecotourism extremely popular as a solution for developing tourism sites. Ecotourism attracts many people who wish not only to explore natural wonders but also to protect them for future generations. Most of the ecotourism sites are presumably situated far from the conventional energy resources and thus transporting electricity to those areas are discussed as inefficient and unsustainable. However, solar Photo-voltaic (PV system is clean and alternative energy to suffice the energy demands of eco-tourist sites. This paper puts statements of the energy demand in global and its impact on the traditional fossil fuels and proposes PV as an alternative renewable technology pertaining to the eco-tourism application. The paper especially focuses on solar PV systems which not only could supply the energy demand of tourist sites but can also maintain the image of the ecotourism. A case of a model lodge is used for the study, through the energy demand analysis. A comprehensive review on the PV architecture is presented that derive interest in the implementation of such structure for the case presented.

  10. PV power system using hybrid converter for LED indictor applications

    International Nuclear Information System (INIS)

    Highlights: • This paper presents a LED indictor driving circuit with a PV arrays as its power source. • The perturb-and-observe method is adopted to extract the maximum power of PV arrays. • The proposed circuit structure has a less component counts and higher conversion efficiency. • A prototype of LED indictor driving circuit has been implemented to verify its feasibility. • The proposed hybrid converter is suitable for LED inductor applications. - Abstract: This paper presents a LED indictor driving circuit with a PV arrays as its power source. The LED indictor driving circuit includes battery charger and discharger (LED driving circuit). In this research, buck converter is used as a charger, and forward converter with active clamp circuit is adopted as a discharger to drive the LED indictor. Their circuit structures use switch integration technique to simplify them and to form the proposed hybrid converter, which has a less component counts, lighter weight, smaller size, and higher conversion efficiency. Moreover, the proposed hybrid converter uses a perturb-and-observe method to extract the maximum power from PV arrays. Finally, a prototype of an LED indictor driving circuit with output voltage of 10 V and output power of 20 W has been implemented to verify its feasibility. It is suitable for the LED inductor applications

  11. Development of solar energy for efficient PV application systems

    International Nuclear Information System (INIS)

    It is essential to increase research, development, awareness for the application of solar energy as an important source of life. The cost of PV systems has decreased due to the improvement in techniques of manufacturing and performance. In reality, photovoltaic is one technology that allows the production of electricity with only two components: technological, which is the PV module and environmental, which is the sun. The knowledge of the components market represents a critical parameters in establishing sustainable industrial applications on different activity sectors. This paper illustrates the advantages of using photovoltaic in rural area and their economic and environmental impact. In regions where petroleum or other fossil fuels are not available, and where these remote area are not connected to the electrical grid, there is a strong and increasing demand for the technologies related to photovoltaic application systems. Water extracting and pumping, telecommunication and lighting, irrigation systems, electrical driven cars and trucks represent some of these important applications. The paper also develops critical skills for the most useful PV application in Egypt and provide to the industry a development forecast for the new technology. Then an initiation contacts and cooperation on PV application between industries specially in North Africa Middle East in order to improve the reliability and to get cheaper systems.(Author)

  12. Rooftop PV system. PV:BONUS Phase 3B, final technical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Under the PV:BONUS Program, ECD and United Solar developed, demonstrated and commercialized two new lightweight, flexible BIPV modules specifically designed as replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and can be used to address the even larger roofing-replacement market. An important design feature of these modules, which minimizes the installation and balance-of-system costs, is their ability to be installed by conventional roofing contractors without special training. The modules are fabricated from high-efficiency, triple-junction spectrum-splitting a-Si alloy solar cells developed by ECD and United Solar. These cells are produced on thin, flexible stainless steel substrates and encapsulated with polymer materials. The Phase 3 program began in August 1995. The principal tasks and goals of this program, which have all been successfully completed by ECD and United Solar, are described in the body and appendices of this report.

  13. PV value analysis: Progress report on PV-Compact Coordinating Council's consensus research agenda

    International Nuclear Information System (INIS)

    A survey of published and ongoing valuation research indicates that grid-connected photovoltaic (PV) technology is at or close to cost-effectiveness, from the utility or end-user point of view, in an increasing but carefully selected array of distributed utility applications. This conclusion is based on conventional analyses of utility avoided costs (energy, effective load carrying capability, and transmission and distribution costs including line losses) and customer benefits (energy and demand bill savings, tax benefits). It may provide the basis for regulatory review of utility transmission or distribution investments to test prudence or usefulness. The conclusion would be stronger with consideration of the values of risk mitigation, power quality, strategic value to utilities, and satisfaction of customer preference. Further work would therefore be useful in quantifying these factors. The economic conclusions prevail irrespective of the structure of the utility industry. However, the analysis is site-specific so its broad application depends on development of easily operated models and other analytical tools for use in the field and by the regulatory process

  14. Large Scale Solar Power Integration in Distribution Grids: PV Modelling, Voltage Support and Aggregation Studies

    NARCIS (Netherlands)

    Samadi, A.

    2014-01-01

    Long term supporting schemes for photovoltaic (PV) system installation have led to accommodating large numbers of PV systems within load pockets in distribution grids. High penetrations of PV systems can cause new technical challenges, such as voltage rise due to reverse power flow during light load

  15. Household photovoltaic market in Xining, Qingha province, China: the role of local PV business

    International Nuclear Information System (INIS)

    This paper assesses the present and future market for household photovoltaic (PV) systems in rural Northwest China, especially from the PV commerce at Xining, Qinghai Province. This unsubsidised free market is now met by the emerging PV industry in China, which includes cell and module manufacturers, and PV system distributors and assemblers. For widespread deployment of such a renewable energy technology, the development of a local free market seems more successful than donor- or 'government subsidy'-driven programmes. Presently, there is a thriving infant PV industry in Northwest China, mostly centred in Xining. Xining-based PV sales companies have extensive networks for selling, marketing and servicing household PV systems for rural farmers and nomads. Small systems are now ordinary items on sale in local shops. Based on interviews and fieldwork observations with seven major PV sales companies in Xining, the household PV market is assessed from the present business operations of these companies. Detail of primary sources is given with the aim of archiving seminal progress in the history of photovoltaic power. The results suggest that although the household PV market will continue to grow, current government and international sponsored PV programmes can create both opportunities and barriers for the infant PV market an industry in China. (author)

  16. Grid Integration of PV Power based on PHIL testing using different Interface Algorithms

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso;

    2013-01-01

    be more active in grid support. Therefore, a better understanding and detailed analysis of the PV systems interaction with the grid is needed; hence power hardware in the loop (PHIL) testing involving PV power became an interesting subject to look into. To test PV systems for grid code (GC...

  17. Importance of policy for energy system transformation: Diffusion of PV technology in Japan and Germany

    International Nuclear Information System (INIS)

    Photovoltaic (PV) has the highest cost reduction potential among all renewable energy sources (RES). To overcome institutional barriers, developing the technology, and creating an initial market, policies are needed. Comparative case studies of Japan and German PV sector from 1990 to 2011 were developed. Japan dominated the PV industry during 1994–2004, PV market increased to 290 MW in 2005. After 2005 Japan's PV market decreased. German PV market increased from 44 MW in 2000 to 7.5 GW in 2011. The reason behind Japanese PV market decline was the unaligned energy policy and termination of incentives. This paper discusses about successful policy implementation and the impact of policy for the diffusion of PV technology. The analysis section of this paper shows how much the PV technology has been diffused during the period of 1990–2011 and finally what will make the transformation process successful. - Highlights: • We studied PV diffusion of Japan and German considering public energy policy, environmental policy and cost reduction. • This study determined that policy and incentives are responsible for cost reduction. • Japans concentration on nuclear energy more than renewables, made the PV diffusion slow. • Successful implementation of FIT helped Germany reduce PV electricity price more than grid electricity

  18. Methodology for the optimal design of tansformerless grid-connected PV interters

    DEFF Research Database (Denmark)

    Koutroulis, E.; Blaabjerg, Frede

    2012-01-01

    inverter, such that the PV inverter levelised cost of the generated electricity is minimised. The proposed method constitutes a systematic design process, which is capable to explore the impact of the PV inverter configuration on the trade-off between the PV inverter manufacturing cost and the power losses...

  19. Modeling Single-Phase PV HB-ZVR Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong; Li, Lijuan; Deng, Wenlang; Blaabjerg, Frede

    2011-01-01

    PLECS is used to model the PV H-bridge zero voltage rectifier (HB-ZVR) inverter connected to grid and good results are obtained. First, several common topologies of PV inverters are introduced. Then the unipolar PWM control strategy is described for PV HB-ZVR inverter. Third, PLECS is briefly int...

  20. Models for a stand-alone PV system[Photovoltaic

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.D.; Soerensen, P.; Hansen, L.H.; Bindner, H.

    2000-12-01

    This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risoe National Laboratory. The work has been supported by the Danish Ministry of Energy, as a part of the activities in the Solar Energy Centre Denmark. The study is carried out at Risoe National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PV system, namely solar cells, battery, controller, inverter and load. The models for PV module and battery are based on the model descriptions found in the literature. The battery model is developed at UMASS and is known as the Kinetic Battery Model (KiBaM). The other component models in the PV system are based on simple electrical knowledge. The implementation is done using Matlab/Simulink, a simulation program that provides a graphical interface for building models as modular block diagrams. The non-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements. The performance of the best linear Black box model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risoe. (au)

  1. Experimental comparison of PV-smoothing controllers using distributed generators

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Denda, Atsushi [Shimizu Corp., Tokyo (Japan); Morino, Kimio [Shimizu Corp., Tokyo (Japan); Hawkins, John N. [Public Service Company of New Mexico, Albuquerque, NM (United States); Arellano, Brian [Public Service Company of New Mexico, Albuquerque, NM (United States); Shinji, Takao [Tokyo Gas Co., New York, NY (United States); Ogata, Takao [Tokyo Gas Co., New York, NY (United States); Tadokoro, Masayuki [Tokyo Gas Co., New York, NY (United States)

    2014-02-01

    The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

  2. The comparison of Virtual Machine Migration Performance between XEN-HVM, XEN-PV, Open-VZ, KVM-FV, KVM-PV

    Directory of Open Access Journals (Sweden)

    Igli Tafa

    2011-08-01

    Full Text Available Based on our previous experience we want to compare theperformance between five hypervisors: XEN-PV, XENHVM,Open-VZ,KVM-FV,KVM-PV We have simulated themigration of a virtual machine by using a warning failureapproach. Based on some experiments we have compared CPUConsumption, Memory Utilization, Total Migration Time andDowntime. We have also tested the hypervisor’s performance bychanging the packet’s size from 1500 byte to 32 byte. From thesetests we have concluded that Open-VZ has a bigger CPUConsumption than XEN-PV, but the Total Migration time issmaller than in XEN-PV. XEN-HVM has a worse performancethan XEN-PV, especially regarding to Downtimeparameter.KVM-FV has the worse performance but it canimprove by modifying it, so in this way we use KVM-PV whichhas approximately the same performance with Xen-HVM

  3. Consequences of Reducing the Cost of PV Modules on a PV Wind Diesel Hybrid System with Limited Sizing Components

    Directory of Open Access Journals (Sweden)

    Jones S. Silva

    2012-01-01

    Full Text Available The use of renewable resources for power supply in family homes has passed the stage of utopia to became a reality, with limits set by technical and economic parameters. This paper presents the results of a project originated from the initiative of a middle-class family to achieve energy independence at home. The starting point was the concept of home with “zero energy” in which the total energy available is equal to the energy consumed. The solution devised to meet the energy demand of the residence in question is a PV wind diesel hybrid system connected to the grid, with the possibility of energy storage in batteries and in the form of heating water and the environment of the house. As a restriction, the family requested that the system would represent little impact to the lifestyle and landscape. This paper aims to assess the consequences of reductions in the cost of the PV modules on the optimization space, as conceived by the software Homer. The results show that for this system, a 50% reduction in the cost of PV modules allows all viable solutions including PV modules.

  4. Integrating High Penetrations of PV into Southern California: Year 2 Project Update; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Mather, B.; Neal, R.

    2012-08-01

    Southern California Edison (SCE) is well into a five-year project to install a total of 500 MW of distributed photovoltaic (PV) energy within its utility service territory. Typical installations to date are 1-3 MW peak rooftop PV systems that interconnect to medium-voltage urban distribution circuits or larger (5 MW peak) ground-mounted systems that connect to medium-voltage rural distribution circuits. Some of the PV system interconnections have resulted in distribution circuits that have a significant amount of PV generation compared to customer load, resulting in high-penetration PV integration scenarios. The National Renewable Energy Laboratory (NREL) and SCE have assembled a team of distribution modeling, resource assessment, and PV inverter technology experts in order to investigate a few of the high-penetration PV distribution circuits. Currently, the distribution circuits being studied include an urban circuit with a PV penetration of approximately 46% and a rural circuit with a PV penetration of approximately 60%. In both cases, power flow on the circuit reverses direction, compared to traditional circuit operation, during periods of high PV power production and low circuit loading. Research efforts during year two of the five-year project were focused on modeling the distribution system level impacts of high-penetration PV integrations, the development and installation of distribution circuit data acquisition equipment appropriate for quantifying the impacts of high-penetration PV integrations, and investigating high-penetration PV impact mitigation strategies. This paper outlines these research efforts and discusses the following activities in more detail: the development of a quasi-static time-series test feeder for evaluating high-penetration PV integration modeling tools; the advanced inverter functions being investigated for deployment in the project's field demonstration and a power hardware-in-loop test of a 500-kW PV inverter implementing a

  5. Results from measurements on the PV-VENT systems at Lundebjerg[DENMARK

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.

    2001-05-01

    The objective of the PV-VENT project was research, development, and tests in the following areas: 1. Develop and illustrate different ways of architectural integration of solar energy systems with combined PV power production and pre-heating of ventilation air in buildings, 2. Investigate the potential in pre-heating fresh air to the building by cooling the PV-panels with the fresh air and further to determine how much this cooling will increase the electrical performance of the PV-panels, 3. Develop and test air to air heat exchangers with an efficiency of 80% or above, 4. Develop and test fans and ventilation systems with an overall fan power demand of about 35 W, 5. Develop and test a direct coupling of the PV-panels to the fans in order to avoid the losses in an inverter, 6. Develop and test different ventilation systems utilizing the abovementioned features. Three different ways of integrating PV-panels with pre-heating of fresh air to the building have been demonstrated in Lundebjerg: a large PV-gable with amorphous PV-panels, a PV-facade with polycrystalline (c-Si) PV-panels and solar ventilation chimneys with polycrystalline (c-Si) PV-panels. Especially the latter feature, the solar ventilation chimney is a new and interesting concept as it allows for increased PV areas although the orientation of the building is not optimal for utilization of solar energy, as was the case in Lundebjerg. It is believed that the PV-VENT project has added important information and experience to the field of combining PV and ventilation systems. Information and experience that future systems of this type may benefit from. Several of the components from the project are believed to be able to contribute to set the standards for future PV and ventilation systems. Several of the components from the project is today commercial available and are used in ordinary building projects. (BA)

  6. Sensitivity of Rooftop PV Projections in the SunShot Vision Study to Market Assumptions

    Energy Technology Data Exchange (ETDEWEB)

    Drury, E.; Denholm, P.; Margolis, R.

    2013-01-01

    The SunShot Vision Study explored the potential growth of solar markets if solar prices decreased by about 75% from 2010 to 2020. The SolarDS model was used to simulate rooftop PV demand for this study, based on several PV market assumptions--future electricity rates, customer access to financing, and others--in addition to the SunShot PV price projections. This paper finds that modeled PV demand is highly sensitive to several non-price market assumptions, particularly PV financing parameters.

  7. Residential Solar PV Planning in Santiago, Chile: Incorporating the PM10 Parameter

    Directory of Open Access Journals (Sweden)

    Gustavo Cáceres

    2014-12-01

    Full Text Available This paper addresses an economic study of the installation of photovoltaic (PV solar panels for residential power generation in Santiago, Chile, based on the different parameters of a PV system, such as efficiency. As a performance indicator, the Levelized Cost of Energy (LCOE was used, which indicates the benefit of the facility vs. the current cost of electrical energy. In addition, due to a high level of airborne dusts typically associated with PM10, the effect of the dust deposition on PV panels’ surfaces and the effect on panel performance are examined. Two different scenarios are analyzed: on-grid PV plants and off-grid PV plants.

  8. NEW-FANGLED ASSIMILATION OF A PV-WIND ENERGY SYSTEM WITH ENHANCED EFFICIENCY

    OpenAIRE

    Y Heman*; Dr.M.SUSHAMA

    2016-01-01

    A novel integration scheme of solar photovoltaic (PV) with a large capacity doubly excited induction generator-based wind energy system is described. The proposed scheme uses both the grid- and rotor-side power converters of doubly fed induction generator to inject PV power into the grid. Thus, it renders a cost-effective solution to PV-grid integration by obviating the need for a dedicated converter for PV power processing. The system is able to feed significantly large PV power into the...

  9. Solar Photovoltaic Economic Development: Building and Growing a Local PV Industry, August 2011 (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2011-08-01

    The U.S. photovoltaic (PV) industry is forecast to grow, and it represents an opportunity for economic development and job creation in communities throughout the United States. This report helps U.S. cities evaluate economic opportunities in the PV industry. It serves as a guide for local economic development offices in evaluating their community?s competitiveness in the solar PV industry, assessing the viability of solar PV development goals, and developing strategies for recruiting and retaining PV companies to their areas.

  10. A Software Tool for Optimal Sizing of PV Systems in Malaysia

    Directory of Open Access Journals (Sweden)

    Tamer Khatib

    2012-01-01

    Full Text Available This paper presents a MATLAB based user friendly software tool called as PV.MY for optimal sizing of photovoltaic (PV systems. The software has the capabilities of predicting the metrological variables such as solar energy, ambient temperature and wind speed using artificial neural network (ANN, optimizes the PV module/ array tilt angle, optimizes the inverter size and calculate optimal capacities of PV array, battery, wind turbine and diesel generator in hybrid PV systems. The ANN based model for metrological prediction uses four meteorological variables, namely, sun shine ratio, day number and location coordinates. As for PV system sizing, iterative methods are used for determining the optimal sizing of three types of PV systems, which are standalone PV system, hybrid PV/wind system and hybrid PV/diesel generator system. The loss of load probability (LLP technique is used for optimization in which the energy sources capacities are the variables to be optimized considering very low LLP. As for determining the optimal PV panels tilt angle and inverter size, the Liu and Jordan model for solar energy incident on a tilt surface is used in optimizing the monthly tilt angle, while a model for inverter efficiency curve is used in the optimization of inverter size.

  11. Voltage stability issues in a distribution grid with large scale PV plant

    Energy Technology Data Exchange (ETDEWEB)

    Perez, Alvaro Ruiz; Marinopoulos, Antonios; Reza, Muhamad; Srivastava, Kailash [ABB AB, Vaesteraas (Sweden). Corporate Research Center; Hertem, Dirk van [Katholieke Univ. Leuven, Heverlee (Belgium). ESAT-ELECTA

    2011-07-01

    Solar photovoltaics (PV) has become a competitive renewable energy source. The production of solar PV cells and panels has increased significantly, while the cost is reduced due to economics of scale and technological achievements in the field. At the same time, the increase in efficiency of PV power systems and high energy prices are expected to lead PV systems to grid parity in the coming decade. This is expected to boost even more the large scale implementation of PV power plants (utility scale PV) and therefore the impact of such large scale PV plants to power system needs to be studies. This paper investigates the voltage stability issues arising from the connection of a large PV power plant to the power grid. For this purpose, a 15 MW PV power plant was implemented into a distribution grid, modeled and simulated using DIgSILENT Power Factory. Two scenarios were developed: in the first scenario, active power injected into the grid by the PV power plants was varied and the resulted U-Q curve was analyzed. In the second scenario, the impact of connecting PV power plants to different points in the grid - resulting in different strength of the connection - was investigated. (orig.)

  12. Overview of PV activities in Japan: current status and future prospects

    International Nuclear Information System (INIS)

    In Japan, activities for dissemination of PV systems have expanded among the national and local governments, industries, academic circles, nonprofit organizations (NPOs), and consumers ever since the Japanese Government laid out the Basic Guidelines for New Energy Introduction in 1994. Particularly, the continuous dissemination programs by the Ministry of Economy, Trade, and Industry (METI) based on the size of PV market has greatly contributed Japan PV industries and the successful creation of the initial market of PV systems. Cumulative installed PV capacity increased from 31.2 MW in 1994 to 859.6 MW in 2003, and 1 GW level is already in sight for 2004. As a result, solar cell/ module manufactures, housing industry, utilities, METI and other ministries and agencies, local governments, NPOs, end-users, etc. are actively promoting deployment of PV systems and the PV market is activated toward achieving 4,820 MW of the target capacity for 2010. The purpose of this paper is to provide an overview of the dissemination process of PV systems by sector and current status of Japan PV market and to forecast the future development to establish the self-sustainable PV market from the perspective of measures and policies, systems, the industrial structure and the PV market. (authors)

  13. How PV system ownership can impact the market value of residential homes.

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor; Johnson, Jamie L.

    2014-01-01

    There are multiple ways for a homeowner to obtain the electricity generating and savings benefits offered by a photovoltaic (PV) system. These include purchasing a PV system through various financing mechanisms, or by leasing the PV system from a third party with multiple options that may include purchase, lease renewal or PV system removal. The different ownership options available to homeowners presents a challenge to appraisal and real estate professionals during a home sale or refinance in terms of how to develop a value that is reflective of the PV systems operational characteristics, local market conditions, and lender and underwriter requirements. This paper presents these many PV system ownership options with a discussion of what considerations an appraiser must make when developing the contributory value of a PV system to a residential property.

  14. Experimental comparison of two PV direct-coupled solar water heating systems with the traditional system

    International Nuclear Information System (INIS)

    Highlights: • A design approach of PV-coupled solar water heating system (SWHS) is presented. • Two different designs of PV modules are proposed and investigated. • A comparative test rig of PV-coupled SWHS and traditional SWHS is set up. • A flow rate increasing with solar irradiation is recommended. - Abstract: Simple and reliable, PV direct-coupled DC pumps are promising in solar water heating systems (SWHS). However, there is limited experimental data on the performance comparison of PV-coupled SWHS with traditional SWHS. Hence in this study, a comparative test rig is set up to measure and analyze the performance of the PV-coupled SWHS and the traditional system under the same conditions. The experimental results show that on sunny days the PV-coupled SWHS has similar daily thermal efficiency as the traditional SWHS, and slightly higher efficiency after improving the design of the PV module. Under low irradiation, the PV-coupled SWHS gains much more heat than the traditional SWHS, which indicates the potential of the PV-coupled SWHS having much higher efficiency than the traditional SWHS on cloudy days. In order to improve the performance of the PV-coupled SWHS, two different designs of PV module are proposed, and their influence on the pump startup characteristics, the flow rate profile, and the thermal efficiency of the system is investigated. It is found that the modified design of the PV module can reduce the requirement of PV cells and increase the efficiency of the system

  15. Development of a monitoring system for a PV solar plant

    International Nuclear Information System (INIS)

    The aim of this paper is to introduce a system developed for monitoring PV solar plants using a novel procedure based on virtual instrumentation. The measurements and processing of the data are made using high precision I/O modular field point (FP) devices as hardware, a data acquisition card as software and the package of graphic programming, LabVIEW. The system is able to store and display both the collected data of the environmental variables and the PV plant electrical output parameters, including the plant I-V curve. A relevant aspect of this work is the development of a unit that allows automatic measuring of the solar plant I-V curve using a car battery as power supply. The system has been in operation during the last two years and all its units have functioned well

  16. Review of Solar PV Market Development in East Africa

    DEFF Research Database (Denmark)

    Hansen, Ulrich Elmer; Pedersen, Mathilde Brix; Nygaard, Ivan

    While the diffusion of solar home systems in Kenya has been market-based for some years, the diffusion of PV in most other Sub-Saharan African countries has been driven by government and donor-supported projects aimed at serving specific needs for electricity while at the same time creating...... to varying degrees by conducive enabling frameworks comprising innovative financing schemes, exemptions from VAT and import taxes, standardised power-purchasing agreements and feed-in tariffs. Few analyses have so far been conducted on the effects of such measures. This paper aims to contribute...... to understanding these effects by reviewing the development of markets for solar PV in Kenya, Tanzania and Uganda, focusing on how the differences in market development have been explained in the literature. The paper finds that, although Tanzania and Uganda are rapidly catching up, Kenya is still leading...

  17. Selecting Solar: Insights into Residential Photovoltaic (PV) Quote Variation

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    Before investing in a system, a prospective PV customer must not only have initial concept 'buy in,' but also be able to evaluate the tradeoffs associated with different system parameters. Prospective customers might need to evaluate disparate costs for each system attribute by comparing multiple bids. The difficulty of making such an evaluation with limited information can create a cognitive barrier to proceeding with the investment. This analysis leverages recently available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  18. High-Penetration PV Integration Handbook for Distribution Engineers

    Energy Technology Data Exchange (ETDEWEB)

    Seguin, Rich [Electrical Distribution Design, Blacksburg, VA (United States); Woyak, Jeremy [Electrical Distribution Design, Blacksburg, VA (United States); Costyk, David [Electrical Distribution Design, Blacksburg, VA (United States); Hambrick, Josh [Electrical Distribution Design, Blacksburg, VA (United States); Mather, Barry [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-01-01

    This handbook has been developed as part of a five-year research project which began in 2010. The National Renewable Energy Laboratory (NREL), Southern California Edison (SCE), Quanta Technology, Satcon Technology Corporation, Electrical Distribution Design (EDD), and Clean Power Research (CPR) teamed together to analyze the impacts of high-penetration levels of photovoltaic (PV) systems interconnected onto the SCE distribution system. This project was designed specifically to leverage the experience that SCE and the project team would gain during the significant installation of 500 MW of commercial scale PV systems (1-5 MW typically) starting in 2010 and completing in 2015 within SCE’s service territory through a program approved by the California Public Utility Commission (CPUC).

  19. Reliability Assessment of Transformerless PV Inverters considering Mission Profiles

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2015-01-01

    Full Text Available Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved by either modifying the modulation schemes or adding extra power switching devices, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redistributed and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature. The mission profile is translated to device thermal loading, which is used for lifetime prediction. Comparison results reveal the lifetime mismatches among the power switching devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency.

  20. Exploiting PV technology for basic need provision in Nigeria

    International Nuclear Information System (INIS)

    Transitional economies are confronted with ever declining standard of living and low per capita income. Development institutions around the world have come to realize the strategic importance of Sustainable Energy as a Basic Need in the development process. Despite the efforts made by emerging democracies to eradicate poverty, there are still millions of people without access to electricity. Unreliable energy supply currently presents a constant obstacle to many poverty alleviation programmes. Against this background, some states government in Nigeria are exploiting the unique advantage offered by PV technology in the provision of Basic Needs. This study appraises some of the scheme in which the authors have been heavily involved with. This paper identifies some of the strategic policies that might accelerate the successful implementation of PV technology as a poverty alleviation tool in terms of electricity provision in transitional economies. (authors)

  1. LonWorks as Fieldbus for PV-Installations; LonWorks als Feldbus fuer PV-Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    Bergen, Ch. von

    2003-07-01

    The growing market for photovoltaics increasingly requires suitable quality controls covering plant operators, planners and installers, as well as the electric utilities. Additionally, the interest of the general public in the behaviour of photovoltaic (PV) plants is growing. This includes information from everyday practice. Alongside data retrieval, other themes such as the operative management of the unit and energy management become increasingly important for grid-connected PV systems. Todays measuring systems are not compatible with each other. Data communication between different PV plants with computer-aided analysis- and visualisation programmes is very complicated. LonWorks was introduced by Motorola and Toshiba in 1991. Today it leads the world market for field bus systems. With plug and play, components by several manufacturers can easily be incorporated into a LonWorks network. Today more than 3,500 companies use LonWorks technology. The goal of this project is to introduce the very popular LonWorks technology as a new standard for PV applications. The first objective was to develop a LonWorks interface for our Convert inverters and to connect them into a small network. In a second step we installed a LonWorks system at the 260 kW{sub p} PV plant 'Felsenau' in Berne, Switzerland. All 68 inverters are controlled over power line with LonWorks. The on-site PC acts as LonWorks DataServer and making remote information monitoring and data gathering possible. As soon as a functional error occurs, an alarm will be transmitted via modem to the SMSC (Short Message Service Centre). After two years of operation we can say that all expectations were fulfilled by our new system. Knowledge gained from this project has shown that LonWorks has lived up its considerable promise and can be regarded as a high-quality piece of technology. Integration into an overall system is technically very easy. To do this, however, relatively expensive software solutions have

  2. Quantify Degradation Rates and Mechanisms of PV Modules and Systems Installed in Florida Through Comprehensive Experimental and Theoretical Analysis (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Sorloaica-Hickman, N.; Davis, K.; Kurtz, S.; Jordan, D.

    2011-02-01

    The economic viability of photovoltaic (PV) technologies is inextricably tied to both the electrical performance and degradation rate of the PV systems, which are the generators of electrical power in PV systems. Over the past 15 years, performance data have been collected on numerous PV systems installed throughout the state of Florida and will be presented.

  3. High Penetration PV: How High Can We Go?

    Energy Technology Data Exchange (ETDEWEB)

    2016-01-01

    Brochure highlighting NREL's partnership with SolarCity and Hawaiian Electric (HECO) to increase the penetration of solar photovoltaics on the electricity grid. To better understand the potential impact of transient overvoltages due to load rejection, NREL collaborated with SolarCity and HECO to run a series of tests measuring the magnitude and duration of load rejection overvoltage events and demonstrating the ability of advanced PV inverters to mitigate their impacts.

  4. Solar PV based rural electrification in Rema rural village

    OpenAIRE

    Admasu, Alemshet Ayele

    2011-01-01

    Energy is a basic need for the overall growth and improvements of people’s living standard.But around 2 to 3 billion people in the world have no access to electric lighting. Like otherdeveloping countries the rural electrification in Ethiopia is very low and government takessome actions to promote the investment in these areas but due to economic constraints andlow level of technological advancement the growth is very low.This study focuses on solar PV based rural electrification, its impact ...

  5. Solar Chimney Model Parameters to Enhance Cooling PV Panel Performance

    OpenAIRE

    Mohammed Sh Elden; K. Sopian; Fatah O. Alghoul; Abdelnasser Abouhnik; Ae. Muftah M.

    2013-01-01

    The concept of using the Solar Chimney plays an important role in a wide range of topics to improve cooling system efficiency such as drying process, and single and multi-story buildings ventilation against temperature rising. In this paper, study the effective solar cooling chimney parameter model to enhance the performance of photovoltaic (PV) cooling system. First, a brief description of theoretical performance predictions of the solar cooling chimney also discusses the effect of the ambie...

  6. Commercial breaks: building the market for PV in Africa

    International Nuclear Information System (INIS)

    The article focuses on the huge potential market for off-grid photovoltaics in Africa, in the sub-Saharan region in particular. However, so far the potential market remains largely untapped and several multimillion-dollar projects aimed at developing the market have been disappointing. The result has been a reduction in the activities of PV companies in Africa. The article seeks reasons for the lack of success and offers suggestions for improving the situation

  7. Storage system requirements for grid supporting PV-power plants

    OpenAIRE

    Gavriluta, Catalin; Candela García, José Ignacio; Rocabert Delgado, Joan; Etxeberria Otadui, Ion; Rodríguez Cortés, Pedro

    2014-01-01

    Large penetration of renewable energy is currently attenuated by concerns regarding their impact on the controllability and reliability of the electrical system. As the inclusion of energy storage is to a great extent the solution to these issues, this paper proposes a methodology for approaching the calculation of the size of the energy storage to be connected to a PV power plant for providing inertia emulation, primary control, and the reduction of power fluctuation. A complete control stra...

  8. Pv rural electrification programme at the Bolivian high plateau

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzo, E.; Aguilera, J. [Instituto de Energia Solar, ETSI Telecomunicacion, (Spain)

    1995-12-31

    Since 1988 the Institute of Solar Energy of the Universidad Politecnica de Madrid is carrying out a pv rural electrification programme at the Bolivian high plateau. This programme has been focused in three aspects: the domestic electrification, users participation and transfer technology. At present, there are about 1,500 electrified dwellings distributed in the Bolivian high plateau. We have got deep knowledge about life style and organization of the aymara Indians who are the inhabitants of the working zone. We think that this knowledge can be very useful for a large scale introduction of PV solar energy in this region. Finally, we present a new way to transfer PV technology to developing countries. Thanks to this programme a group of aymara Indians is able to manufacture charge regulators and electronic ballast to use in the PV installations of the programme. [Espanol] Desde 1988 el Instituto de Energia Solar de la Universidad Politecnica de Madrid esta llevando a cabo un programa fotovoltaico de electrificacion rural en la altiplanicie Boliviana. Este programa ha sido enfocado a tres aspectos: la electrificacion domestica, la participacion de los usuarios y la transferencia de la tecnologia. Actualmente, hay alrededor de 1500 conjuntos habitacionales electrificados distribuidos en la altiplanicie Boliviana. Hemos obtenido un profundo conocimiento del estilo de vida y de la organizacion de los indios aymara que son los habitantes de la zona de trabajo. Pensamos que este conocimiento puede ser muy util para una introduccion en gran escala de la energia solar fotovoltaica en esta region. Finalmente, presentamos una nueva forma de transferir la tecnologia fotovoltaica a paises en desarrollo. Gracias a este programa un grupo de indios aymara pueden fabricar reguladores de carga y balastros electronicos para ser usados en instalaciones fotovoltaicas del programa.

  9. Diagnostic impact of bone marrow histopathology in polycythemia vera (PV)

    OpenAIRE

    Thiele, J; Kvasnicka, H M

    2005-01-01

    The criteria of the Polycythemia Vera Study Group (PVSG), although acknowledged as the gold standard to establish the diagnosis of polycythemia vera (PV), do not regard bone marrow (BM) histopathology. Arguments include the existence of sufficient objective markers of disease and the lack of independently performed morphological studies or standardized criteria. The aim of this review is to evaluate morphological characteristics of erythrocytosis and to det...

  10. Sizing PV-wind hybrid energy system for lighting

    Directory of Open Access Journals (Sweden)

    Mustafa Engin

    2012-09-01

    Full Text Available Sizing of wind and photovoltaic generators ensures lower operational costs and therefore, is considered as an important issue. An approach for sizing along with a best management technique for a PV-wind hybrid system with batteries is proposed in this paper, in which the best size for every component of the system could be optimized according to the weather conditions and the load profile. The average hourly values for wind speed and solar radiation for Izmir, Turkey has been used in the design of the systems, along with expected load profile. A hybrid power model is also developed for battery operation according to the power balance between generators and loads used in the software, to anticipate performances for the different systems according to the different weather conditions. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Using proposed procedure, a 1.2 kWp PV-wind hybrid system was designed for Izmir, and simulated and measured results are presented.

  11. Overcoming PV grid issues in the urban areas

    Energy Technology Data Exchange (ETDEWEB)

    Ehara, T.

    2009-10-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at grid issues in urban photovoltaic electricity and how to overcome them. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy as a significant and sustainable renewable energy option. The objective of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. The paper discusses the goal of mainstreaming PV systems in the urban environment. In this report, PV grid interconnection issues and countermeasures based on the latest studies are identified and summarised. Appropriate and understandable information is provided for all possible stakeholders. Possible impacts and benefits of PV grid interconnection are identified, technical measures designed to eliminate negative impacts and enhance possible benefits are presented. The status of research and demonstration projects is introduced and the latest outcomes are summarised. Recommendations and conclusions based on the review process are summarised and presented.

  12. Power Electronic System for Multi-MW PV sites

    DEFF Research Database (Denmark)

    Paasch, Kasper

    2016-01-01

    in Sønderborg (DK) was implemented. A total of 17 PV-inverters have been monitored during a period exceeding one year and the recorded data constitutes the basis of this investigation. A part of the 2.1 MW PV plant was reconfigured to emulate the behavior of a central-inverter and solar panels...... distributed over a distance of 160 m. In parallel a string based inverter configuration was established with solar panels at the same locations. An analysis of irradiation data recorded during the test period showed that non-uniform irradiance due to moving clouds is expected to influence the PV plants for...... production by approximately 0.4%. A portable IV-scanning instrument for the fast long term characterization of solar panels was developed as part of the project. Each second a sweep of the IV-characteristics of a solar panel is performed and the result stored for later analysis. The instrument is based on an...

  13. Rooftop PV system. Final technical progress report, Phase II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    Under this four-year PV:BONUS Program, ECD and United Solar are developing and demonstrating two new lightweight flexible building integrated Photovoltaic (BIPV) modules specifically designed as exact replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and address the even larger roofing replacement market. The modules are designed to be installed by roofing contractors without special training which minimizes the installation and balance of system costs. The modules will be fabricated from high-efficiency, multiple-junction a-Si alloy solar cells developed by ECD and United Solar. Under the Phase I Program, which ended in March 1994, we developed two different concept designs for rooftop PV modules: (1) the United Solar overlapping (asphalt shingle replacement) shingle-type modules and (2) the ECD metal roof-type modules. We also developed a plan for fabricating, testing and demonstrating these modules. Candidate demonstration sites for our rooftop PV modules were identified and preliminary engineering designs for these demonstrations were developed; a marketing study plan was also developed. The major objectives of the Phase II Program, which started in June 1994 was (1) to develop, test, and qualify these new rooftop modules; (2) to develop mechanical and electrical engineering specifications for the demonstration projects; and (3) to develop a marketing/commercialization plan.

  14. A Variable PV Broad Absorption Line and Quasar Outflow Energetics

    CERN Document Server

    Capellupo, Daniel M; Barlow, Tom A

    2014-01-01

    Broad absorption lines (BALs) in quasar spectra identify high velocity outflows that might exist in all quasars and could play a major role in feedback to galaxy evolution. The viability of BAL outflows as a feedback mechanism depends on their kinetic energies, as derived from the outflow velocities, column densities, and distances from the central quasar. We estimate these quantities for the quasar, Q1413+1143 (redshift $z_e = 2.56$), aided by the first detection of PV $\\lambda\\lambda$1118,1128 BAL variability in a quasar. In particular, PV absorption at velocities where the CIV trough does not reach zero intensity implies that the CIV BAL is saturated and the absorber only partially covers the background continuum source (with characteristic size 22.3 (cm^-2). Variability in the PV and saturated CIV BALs strongly disfavors changes in the ionization as the cause of the BAL variability, but supports models with high-column density BAL clouds moving across our lines of sight. The observed variability time of ...

  15. Mass productions of thin film silicon PV modules

    International Nuclear Information System (INIS)

    Mass production technologies of a-Si single junction and a-Si/poly-Si hybrid modules with stable 8% and 10% efficiency were developed in the Shiga factory of Kaneka Corporation. Kaneka instituted Kaneka Solartech Corporation (KST) as a subsidiary company of 100% shareholder and invested 20 MW production plant in Toyooka City in 1999. There are fully automatic thin film fabrication equipments. KST started the manufacturing amorphous silicon PV modules in 1999 and those of hybrid type PV modules in 2001. The largest size glass substrates used for these modules are 95x98 cm and variable size of modules are being produced by cutting these large area base modules. Recent production yields are higher than 98%. Production technologies of a-Si, thin c-Si and solar cells, performances of modules, applications to the rooftop PV systems will be presented. We estimate the production cost of a-Si solar modules and a-Si/thin c-Si hybrid solar modules. The future business plan of our new type solar modules and our production lines will be discussed. (author)

  16. Performance of a directly-coupled PV water pumping system

    International Nuclear Information System (INIS)

    Highlights: → Directly coupled PV water pumping system installed and performance studied. → Configured for two static heads, operate without electronic control and auxiliary power. → The system attains steady state soon after any abrupt change. → Cost effective and useful for low head communicating wells system. - Abstract: This paper describes the experimental study carried out to investigate the performance of a simple, directly coupled dc photovoltaic (PV) powered water pumping system. The system comprises of a 1.5 kWp PV array, dc motor and a centrifugal pump. The experiment was conducted over a period of 4 months and the system performance was monitored under different climatic conditions and varying solar irradiance with two static head configurations. Although the motor-pump efficiency did not exceed 30%, which is typical for directly-coupled photovoltaic pumping systems, such a system is clearly suitable for low head irrigation in the remote areas, not connected to the national grid and where access to water comes as first priority issue than access to technology. The system operates without battery and complex electronic control, therefore not only the initial cost is low but also maintenance, repairing and replacement cost can be saved. The study showed that directly coupled system attains steady state soon after any abrupt change.

  17. Pv rural electrification in Kiribati: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Hurry, Suresh [Energy and Atmosphere Programme, SEED/BPPS UNDP, New York (United States)

    1995-12-31

    In collaboration with the Japan International Cooperation Agency (JICA), United Nations Development Programme (UNDP) participated in the implementation of a photovoltaic (PV) rural electrification project in Kiribati. Under this project, assistance was provided to the Kiribati Solar Energy Company (SEC) in order to enable it to provide electricity service as a micro utility in a effective manner. The assistance provided included installation of 55 PV-based solar home systems and one community system. In addition, the assistance focussed on technical training of SEC personnel on PV systems and management training on accounting, billing, spare parts inventory, etcetera. [Espanol] En colaboracion con la Japan International Cooperation Agency (JICA), el Programa de las Naciones Unidas para el Desarrollo (PNUD) participo en la puesta en practica de un proyecto de electrificacion rural fotovoltaico en Kiribati. Dentro de este proyecto, se proporciono ayuda a la Kiribati Solar Energy Company (SEC) para ponerla en condicion de suministrar el servicio electrico, en una forma efectiva, como una micro empresa electrica. La ayuda proporcionada incluyo la instalacion de 55 sistemas domesticos solares fotovoltaicos y un sistema comunitario. Adicionalmente, la ayuda se enfoco al entrenamiento tecnico del personal de SEC en sistemas fotovoltaicos y en el entrenamiento administrativo en contabilidad, facturacion, inventariado de partes de repuesto, etc.

  18. Modeling and Simulation for Hybrid of PV-Wind system

    Directory of Open Access Journals (Sweden)

    Maged N. F. Nashed

    2015-04-01

    Full Text Available The rising consumption rate of fossil fuels causes a significant pollution impact on the atmosphere, unwanted greenhouse gases has drawn worldwide attention towards renewable energy sources. Moreover, in recent year’s generation of electricity using the different types of renewable sources are specifically evaluated in the economical performance of the overall equipment. This paper focuses on the modeling and analysis of a Standalone Photovoltaic (PV- wind energy hybrid generation system under different conditions using MATLAB. The proposed system consists of two renewable sources i.e. wind and solar energy. Modeling of PV array and wind turbine is explained. The wind subsystem is equipped of an induction generator. In photovoltaic system, the variable DC output voltage is controlled using buck-boost converter for the MPPT. These two systems are combined to operate in parallel and the common bus collects the total energy from the wind and PV systems are uses it to the load and with change the load

  19. Performance analysis of PV plants: Optimization for improving profitability

    International Nuclear Information System (INIS)

    Highlights: ► Real PV production from two 100 kWp grid-connected installations is conducted. ► Data sets on production were collected over an entire year. ► Economic results highlight the importance of properly selecting the system components. ► Performance of PV plants is directly related to improvements of all components. - Abstract: A study is conducted of real PV production from two 100 kWp grid-connected installations located in the same area, both of which experience the same fluctuations in temperature and radiation. Data sets on production were collected over an entire year and both installations were compared under various levels of radiation. The installations were assembled with mono-Si panels, mounted on the same support system, and the power supply was equal for the inverter and the measurement system; the same parameters were also employed for the wiring, and electrical losses were calculated in both cases. The results, in economic terms, highlight the importance of properly selecting the system components and the design parameters for maximum profitability.

  20. Yield of PV-generated energy by small scale PV system at a site of Sofia, Bulgaria

    International Nuclear Information System (INIS)

    A 36W PV module has been installed on the building of Solar Energy Lab in Sofia. The purpose of this demonstration is to determine practically the amount of energy can be produced for a fixed period of time and to assess the opportunity for solar power application in small utility systems in Bulgaria. This paper reports the results of testing a module over spring and summer time when solar insolation reaches its maximum. The data measured include operation weather variables, DC and thermal performance of a module. These data were analyzed to calculate average PV-generated energy for a sunny day and for a whole month (April 1995). Empirical thermal dissipation coefficient for the developed module assembly is also extracted from the data. (author). 1 ref., 4 figs

  1. PV-Developer. A Concept Paper. Version 4.0

    International Nuclear Information System (INIS)

    The market for Photovoltaic Energy systems is developing very rapidly with annual growth rates in the range of 20-40%. The growth creates new business opportunities for project development. The markets are immature and the competitiveness of PV is increasing, whereby it is important to develop the business concept within the next few years if the long-term aim is to become a major player in the field of PV-project development. Like in the field of wind energy, which has grown to a large-scale business area within the last decade, the long-term perspectives of photovoltaic energy will depend upon the market development, interest groups and stake holders. The solar power developers might be catalysts for high growth rates like in the wind energy field. The concern for global warming leads the international energy policies in favour of renewable energy incentives followed by the technological development of PV-equipment, which constantly improves the cost level of PV-produced electricity. The markets for PV-systems are geographically widespread and the way to implement systems goes to a large extent via financing from international governmental as well as non-governmental lateral and bilateral aid organisations. Lead times to develop projects are counted in years, and the time from the first project idea to the final commissioning of the installed plants might take 3-5 years. More specific studies of market segments and business opportunities, development of market penetration and design of strategy must be carried out. Organisation seems to be a major issue as the complexity of the projects and the project location in 3rd world countries as well as in the industrialised countries combined with high proportion of donor funding will require a high level of organisation and coordination. In general a detailed study should be made in order to create a business plan. The business plan must contain budgets, volume estimates, sensitivity analyses, organisational proposals

  2. Espace-PV: Key Sensitive Parameters for Environmental Impacts of Grid-Connected PV Systems With LCA

    OpenAIRE

    Blanc, Isabelle; Beloin-Saint-Pierre, Didier; Payet, Jérôme; Jacquin, Philippe; Adra, Nadine; Mayer, Didier

    2008-01-01

    The study of sensitive parameters for the life cycle analysis (LCA) of PV system showed that irradiation intensity will bring the biggest variation on environmental impact when considering regions with large difference in solar irradiation level. For example, in France a system installed in the northern region will produce electricity with more than a 100% of the impact of a southern system. Other important factors are the lifetime of the system and the associated electricity use for the diff...

  3. Commercialization and business development of grid-connected PV at SMUD

    International Nuclear Information System (INIS)

    SMUD has completed its first 5 year, 6 MW PV commercialization effort based on the sustained, orderly development of the utility PV market. SMUD has begun a 5 year, 10 MW program designed to complete a process that will result in PV being at a market competitive price by 2002 and as a sustainable business opportunity for SMUD. As part of this effort, by the end of 1997, SMUD had installed over 450 PV systems totaling 6 MW. These included over 420 residential rooftop systems as well as commercial buildings, parking lots and substation systems. Under its new Business Plan, SMUD has signed contracts for an additional 10 MW of PV systems for 1998 through 2002 with cost decreasing to less than $3/W. As part of its new competitive business strategy responding to changes the utility industry is undergoing, SMUD has incorporated PV as a key business opportunity. SMUD has established partnerships with its customers through the PV Pioneer green pricing program, with DOE and UPVG through TEAM-UP and Million Solar Roofs to advance PV commercialization and to develop rooftops as PV power plant sites and with other utilities through its PV Partnership program

  4. Evaluating the limits of solar photovoltaics (PV) in traditional electric power systems

    International Nuclear Information System (INIS)

    In this work, we examine some of the limits to large-scale deployment of solar photovoltaics (PV) in traditional electric power systems. Specifically, we evaluate the ability of PV to provide a large fraction (up to 50%) of a utility system's energy by comparing hourly output of a simulated large PV system to the amount of electricity actually usable. The simulations use hourly recorded solar insolation and load data for Texas in the year 2000 and consider the constraints of traditional electricity generation plants to reduce output and accommodate intermittent PV generation. We find that under high penetration levels and existing grid-operation procedures and rules, the system will have excess PV generation during certain periods of the year. Several metrics are developed to examine this excess PV generation and resulting costs as a function of PV penetration at different levels of system flexibility. The limited flexibility of base load generators produces increasingly large amounts of unusable PV generation when PV provides perhaps 10-20% of a system's energy. Measures to increase PV penetration beyond this range will be discussed and quantified in a follow-up analysis

  5. An aquaporin PvTIP4;1 from Pteris vittata may mediate arsenite uptake.

    Science.gov (United States)

    He, Zhenyan; Yan, Huili; Chen, Yanshan; Shen, Hongling; Xu, Wenxiu; Zhang, Haiyan; Shi, Lei; Zhu, Yong-Guan; Ma, Mi

    2016-01-01

    The fern Pteris vittata is an arsenic hyperaccumulator. The genes involved in arsenite (As(III)) transport are not yet clear. Here, we describe the isolation and characterization of a new P. vittata aquaporin gene, PvTIP4;1, which may mediate As(III) uptake. PvTIP4;1 was identified from yeast functional complement cDNA library of P. vittata. Arsenic toxicity and accumulating activities of PvTIP4;1 were analyzed in Saccharomyces cerevisiae and Arabidopsis. Subcellular localization of PvTIP4;1-GFP fusion protein in P. vittata protoplast and callus was conducted. The tissue expression of PvTIP4;1 was investigated by quantitative real-time PCR. Site-directed mutagenesis of the PvTIP4;1 aromatic/arginine (Ar/R) domain was studied. Heterologous expression in yeast demonstrates that PvTIP4;1 was able to facilitate As(III) diffusion. Transgenic Arabidopsis showed that PvTIP4;1 increases arsenic accumulation and induces arsenic sensitivity. Images and FM4-64 staining suggest that PvTIP4;1 localizes to the plasma membrane in P. vittata cells. A tissue location study shows that PvTIP4;1 transcripts are mainly expressed in roots. Site-directed mutation in yeast further proved that the cysteine at the LE1 position of PvTIP4;1 Ar/R domain is a functional site. PvTIP4;1 is a new represented tonoplast intrinsic protein (TIP) aquaporin from P. vittata and the function and location results imply that PvTIP4;1 may be involved in As(III) uptake. PMID:26372374

  6. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  7. Optimal Planning Strategy for Large PV/Battery System Based on Long-Term Insolation Forecasting

    Science.gov (United States)

    Yona, Atsushi; Uchida, Kosuke; Senjyu, Tomonobu; Funabashi, Toshihisa

    Photovoltaic (PV) systems are rapidly gaining acceptance as some of the best alternative energy sources. Usually the power output of PV system fluctuates depending on weather conditions. In order to control the fluctuating power output for PV system, it requires control method of energy storage system. This paper proposes an optimization approach to determine the operational planning of power output for PV system with battery energy storage system (BESS). This approach aims to obtain more benefit for electrical power selling and to smooth the fluctuating power output for PV system. The optimization method applies genetic algorithm (GA) considering PV power output forecast error. The forecast error is based on our previous works with the insolation forecasting at one day ahead by using weather reported data, fuzzy theory and neural network(NN). The validity of the proposed method is confirmed by the computer simulations.

  8. Designing PV Incentive Programs to Promote Performance: A Reviewof Current Practice

    Energy Technology Data Exchange (ETDEWEB)

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2007-06-01

    Increasing levels of financial support for customer-sited photovoltaic (PV) systems, provided through publicly-funded incentive programs, has heightened concerns about the long-term performance of these systems. Given the barriers that customers face to ensuring that their PV systems perform well, and the responsibility that PV incentive programs bear to ensure that public funds are prudently spent, these programs should, and often do, play a critical role in ensuring that PV systems receiving incentives perform well. To provide a point of reference for assessing the current state of the art, and to inform program design efforts going forward, we examine the approaches to encouraging PV system performance used by 32 prominent PV incentive programs in the U.S. We identify eight general strategies or groups of related strategies that these programs have used to address performance issues, and highlight important differences in the implementation of these strategies among programs.

  9. Bifacial PV system in Aichi Airport-site Demonstrative Research Plant for New Energy Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Araki, Ichiro; Nakahara, Hirotaka; Tomita, Takashi [Photovoltaic Solar Cells and Modules Business Department, Power Systems, Hitachi Ltd., 1-1 Saiwai-cho 3-chome, Hitachi-shi, Ibaraki 317-8511 (Japan); Tatsunokuchi, Mitsuhiro [Urban Development Solution Div., Urban Planning and Development Systems, Hitachi Ltd., Akihabara UDX Building, 14-1 Soto-Kanda 4-chome, Chiyoda-ku, Tokyo 101-8010 (Japan)

    2009-06-15

    NEDO Demonstrative Project of Regional Power Grids with Various New Energies includes several kinds of FC system and PV system with sodium-sulfur battery. One of the PV systems is vertically installed fence-type bifacial PV system, 30 kW for its front surface Pmax. The bifacial PV worked as an outer fence of the global loop in the EXPO 2005 Aichi, Japan. The whole generation system was moved from the site of the EXPO 2005 to the site near the Aichi Airport, and then it re-started its power generation in September 2006 as the Aichi Airport-site Demonstrative Research Plant for New Energy Power Generation, where the bifacial PV array was installed on the ground faced to southwest and northeast. The paper introduces the outline of the plant and describes the evaluation of actual yearly generation of the bifacial PV system. (author)

  10. Optimal design of NPC and Active-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    Targeting at a cost-effective deployment of grid-connected PhotoVoltaic (PV) systems, this paper presents a new methodology for the optimal design of transformerless PV inverters, which are based on the Neutral Point Clamped (NPC) and the Active-Neutral Point Clamped (ANPC) topologies. The design...... optimal design methodology enables to maximize the economic benefit obtained during the lifetime period of the installed PV system....

  11. Design and Control of Charge-Pumped Reboost Converter for PV Applications

    OpenAIRE

    Hutchens, Christopher L

    2010-01-01

    Photovoltaic (PV) systems are renewable, DC sources which provide non-linear output power with respect to PV panel operating voltage or current. The majority of PV sources yield poor conversion efficiencies between available solar radiation and electrical output. Additionally, they are expensive compared to other conventional power sources. Power electronic converters are capable of harvesting the most energy from these resources due to their configurability and high-efficiency. These convert...

  12. Method for Load Sharing and Power Management in a Hybrid PV/Battery Source Islanded Microgrid

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Guerrero, Josep M.;

    2016-01-01

    This paper presents a decentralized load sharing and power management method for an islanded microgrid composed of PV units, battery units and hybrid PV/battery units. The proposed method performs all the necessary tasks such as load sharing among the units, battery charging and discharging and PV...... power curtailment with no need to any communication among the units. The proposed method is validated experimentally....

  13. Large Scale Deployment of PV Units in Existing Distribution Networks: Optimization of the Installation Layout

    OpenAIRE

    Sossan, Fabrizio; Darulová, Jana; Paolone, Mario; Kahl, Annelen; Bartlett, Stuart John; Lehning, Michael

    2016-01-01

    In fixed PV installations, the azimuth and tilt of the panels are normally chosen with the objective of maximizing the plant capacity factor. In this paper, we show that when considering distribution networks with densely clustered PV plants, there exist installation criteria other than the conventional that achieve higher net PV production without violating distribution network constraints. In particular, we formulate an optimization problem to determine the siting, sizing, azimuth and tilt ...

  14. Final Technical Report: Advanced Measurement and Analysis of PV Derate Factors.

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce Hardison [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burton, Patrick D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hansen, Clifford [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The Advanced Measurement and Analysis of PV Derate Factors project focuses on improving the accuracy and reducing the uncertainty of PV performance model predictions by addressing a common element of all PV performance models referred to as “derates”. Widespread use of “rules of thumb”, combined with significant uncertainty regarding appropriate values for these factors contribute to uncertainty in projected energy production.

  15. A Hybrid Power Control Concept for PV Inverters with Reduced Thermal Loading

    OpenAIRE

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede; Kerekes, Tamas

    2014-01-01

    This letter proposes a hybrid power control concept for grid-connected Photovoltaic (PV) inverters. The control strategy is based on either a Maximum Power Point Tracking (MPPT) control or a Constant Power Generation (CPG) control depending on the instantaneous available power from the PV panels. The essence of the proposed concept lies in the selection of an appropriate power limit for the CPG control to achieve an improved thermal performance and an increased utilization factor of PV invert...

  16. Study on Fault and Isolated Condition in Two Circuit Configurations of PV-ESS Hybrid System

    OpenAIRE

    Myo Htaik; Ryoichi Hara; Hiroyuki Kita

    2012-01-01

    Most photovoltaic (PV) generation systems are connected with a utility grid and recognized as supplemental generation resources; but in some applications such as microgrid concept, a PV system works as a main resource. To improve the availability of PV systems, technological development for higher less output fluctuation in normal condition, higher fault tolerance in fault occurrence, and power demand and supply balancing in isolated condition are required. For these reasons, hybridization of...

  17. Optimal design of orientation of PV/T collector with reflectors

    International Nuclear Information System (INIS)

    Hybrid conversion of solar radiation implies simultaneous solar radiation conversion into thermal and electrical energy in the PV/Thermal collector. In order to get more thermal and electrical energy, flat solar radiation reflectors have been mounted on PV/T collector. To obtain higher solar radiation intensity on PV/T collector, position of reflectors has been changed and optimal position of reflectors has been determined by both experimental measurements and numerical calculation so as to obtain maximal concentration of solar radiation intensity. The calculated values have been found to be in good agreement with the measured ones, both yielding the optimal position of the flat reflector to be the lowest (5o) in December and the highest (38o) in June. In this paper, the thermal and electrical efficiency of PV/T collector without reflectors and with reflectors in optimal position have been calculated. Using these results, the total efficiency and energy-saving efficiency of PV/T collector have been determined. Energy-saving efficiency for PV/T collector without reflectors is 60.1%, which is above the conventional solar thermal collector, whereas the energy-saving efficiency for PV/T collector with reflectors in optimal position is 46.7%, which is almost equal to the values for conventional solar thermal collector. Though the energy-saving efficiency of PV/T collector decreases slightly with the solar radiation intensity concentration factor, i.e. the thermal and electrical efficiency of PV/T collector with reflectors are lower than those of PV/T collector without reflectors, the total thermal and electrical energy generated by PV/T collector with reflectors in optimal position are significantly higher than total thermal and electrical energy generated by PV/T collector without reflectors.

  18. Concentrating PV/T Hybrid System for Simultaneous Electricity and Usable Heat Generation: A Review

    OpenAIRE

    Longzhou Zhang; Dengwei Jing; Liang Zhao; Jinjia Wei; Liejin Guo

    2012-01-01

    Photovoltaic (PV) power generation is one of the attractive choices for efficient utilization of solar energy. Considering that the efficiency and cost of PV cells cannot be significantly improved in near future, a relatively cheap concentrator to replace part of the expensive solar cells could be used. The photovoltaic thermal hybrid system (PV/T), combining active cooling with thermal electricity and providing both electricity and usable heat, can enhance the total efficiency of the system ...

  19. On the value of decentralised PV systems for the GCC residential sector

    International Nuclear Information System (INIS)

    Based on the rich natural potential of the Gulf region, solar energy is expected to play a greater role in the future of the Gulf Corporation Council (GCC) countries. This study examines whether the integration of the photovoltaic (PV) into individual residential buildings in the GCC countries is worth the investment. A prototype residential building is developed and a building integrated photovoltaic (BiPV) system is then designed. The system performance is simulated, and through economic analysis, it is shown that the current BiPV technology is not a cost-effective option for the GCC countries based on the present electricity tariff, PV system cost and system efficiency. The only way such a system would be viable with current technology is if the electricity tariff were to increase substantially. However, if the tariff remains constant for the foreseeable future, BiPV solar energy technology will only be feasible if the total system cost drops drastically. This study shows that BiPV systems offer cost reductions in both energy and economic terms over centralised PV plants, especially if the costs of avoided building construction materials are taken into account. To bring about the benefits of BiPV technology for the GCC residential sector, therefore, the first logical and most practical step is the implementation of a continuous promotion strategy that consists of both subsidies for investments and reasonable tariffs. - Research highlights: → Techno-economic analysis of decentralised PV systems for the GCC residential sector. → The current BiPV technology is not a cost-effective option for the GCC countries based on the present electricity tariff, PV system cost and system efficiency. → The only way such a system would be viable with current technology is if the electricity tariff were to increase substantially. → If the tariff remains constant for the foreseeable future, BiPV solar energy technology will only be feasible if the total system cost drops

  20. Distributed Solar PV for Electricity System Resiliency: Policy and Regulatory Considerations (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    Distributed Solar PV systems have the potential of increasing the grid's resiliency to unforeseen events, such as extreme weather events and attacks. This paper presents the role that distributed PV can play in electric grid resiliency, introduces basic system design requirements and options, and discusses the regulatory and policy options for supporting the use of distributed PV for the purpose of increased electricity resiliency.

  1. Optimal Capacity Allocation of Large-Scale Wind-PV-Battery Units

    OpenAIRE

    2014-01-01

    An optimal capacity allocation of large-scale wind-photovoltaic- (PV-) battery units was proposed. First, an output power model was established according to meteorological conditions. Then, a wind-PV-battery unit was connected to the power grid as a power-generation unit with a rated capacity under a fixed coordinated operation strategy. Second, the utilization rate of renewable energy sources and maximum wind-PV complementation was considered and the objective function of full life cycle-net...

  2. Fire risk related to the use of PV systems in building facades

    OpenAIRE

    Mazziotti Lamberto; Cancelliere Piergiacomo; Paduano Giuseppe; Setti Paolo; Sassi Samuele

    2016-01-01

    Nowadays the use of photovoltaic (PV) systems in buildings is not only related to the solar energy conversion into electrical one, but these PV modules or panels could also be used with aesthetic features or, even more, as thermal protection systems in building facades. Thanks to the technical development of the photovoltaic industry, PV system can easily be architectonically integrated into building construction elements such as roofs, vertical façade components, both with opaque or transpar...

  3. Building integrated multi PV/T/A solar system

    International Nuclear Information System (INIS)

    Previous development in solar energy for residential applications proved that there is merit in further development and improvement of combined electricity and hot water and hot air collectors. The justification stems from the fact that waste heat is generated when PV cells are producing electricity but it decrease its efficiency dramatically, and any effective way to cool the cells can improve their efficiency and long while the heat that generated from this cooling process could be stored and used as standard solar hot water/air system. The core unit comprises of integrated PV cells mounted on a flat-plate collector for water and air, hot water storage tank hot air inlet pips to the house electric battery bank, inverter, connecting cables and controller. Double-glazing serving as solar trap to triple the amount of sun ray reaching the PV cells and other technical innovation make the system more cost effective and cost benefit for stand alone and grid connected domestic application. Two way interconnection with the electric grid like in all the roof top program may bring it to economic viability by selling excess electricity during the costly peak hours while buying low cost electricity during the night off-peak hours, and free electricity from the sun plus free hot water and hot air for domestic use as by-product. A basic domestic two-collector system may deliver up to 4 kWh of electricity and 12000 kcal of hot water and air daily. Some 22 systems are currently operating at various locations in Israel, some for 8 years with very good results. (Author)

  4. The microcomputer-based expert system in CAD-PV

    International Nuclear Information System (INIS)

    As a branch of artificial intelligence, expert system has been revealed day after day in more and more engineering scopes since the successful applications of MYCIN in diagnosis and DENDRAL in the molecular structure of organic compounds etc.. But in the design scope of pressure vessel, as we know, only a few papers have so far been published with respect to the expert system. The necessity and feasibility of accompanying CAD-PV with expert system attracted more scholars to engage in. Although many countries, including China, have regularized the design standards or codes for pressure vessel, but of which no one can solve all of the problems concerning the various practical occasions and experiences. In general, the more domain knowledges a design engineer possesses of, the better decision will be made by him. By virtue of the expert system any less experienced engineer could make the optimum decision in design as well as a skilled senior engineer in addition to the application of design code. It is the due significance for developing high level expert system as an intelligence assistant in the plan option of CAD-PV. In this paper we attempt to introduce a specified software JACKPV used in the design procedure of jacketed pressure vessel as an intelligence front in CAD-PV. JACKPV consists of the function of expert system based on the personal computer IBM-PC/XT with the language PASCAL in its program. It was proved that an ordinary CAD software could be effectively improved while equipped with expert system. (orig.)

  5. Life cycle assessment study of solar PV systems: An example of a 2.7kW{sub p} distributed solar PV system in Singapore

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, R.; Leong, K.C.; Osman, R.; Ho, H.K. [School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Tso, C.P. [Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, 75450 Melaka (Malaysia)

    2006-05-15

    In life cycle assessment (LCA) of solar PV systems, energy pay back time (EPBT) is the commonly used indicator to justify its primary energy use. However, EPBT is a function of competing energy sources with which electricity from solar PV is compared, and amount of electricity generated from the solar PV system which varies with local irradiation and ambient conditions. Therefore, it is more appropriate to use site-specific EPBT for major decision-making in power generation planning. LCA and life cycle cost analysis are performed for a distributed 2.7kW{sub p} grid-connected mono-crystalline solar PV system operating in Singapore. This paper presents various EPBT analyses of the solar PV system with reference to a fuel oil-fired steam turbine and their greenhouse gas (GHG) emissions and costs are also compared. The study reveals that GHG emission from electricity generation from the solar PV system is less than one-fourth that from an oil-fired steam turbine plant and one-half that from a gas-fired combined cycle plant. However, the cost of electricity is about five to seven times higher than that from the oil or gas fired power plant. The environmental uncertainties of the solar PV system are also critically reviewed and presented. (author)

  6. Estimation of Maximum Allowable PV Connection to LV Residential Power Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2011-01-01

    Maximum photovoltaic (PV) hosting capacity of low voltage (LV) power networks is mainly restricted by either thermal limits of network components or grid voltage quality resulted from high penetration of distributed PV systems. This maximum hosting capacity may be lower than the available solar...... potential of geographic area due to power network limitations even though all rooftops are fully occupied with PV modules. Therefore, it becomes more of an issue to know what exactly limits higher PV penetration level and which solutions should be engaged efficiently such as over sizing distribution...

  7. PV market in Germany and activities of the metropolitan utility of Karlsruhe

    International Nuclear Information System (INIS)

    The introduction of the Renewable Energy Law in Germany in combination with the 100,000 roof program lead to an explosion of the market for grid-connected PV systems, with all possible effects such as the formation of new PV companies, job creation and the installation of a huge number of PV systems. But there is also one negative aspect: higher prices for the modules due to production bottle-necks. The Municipal Utility of Karlsruhe (SWK) commits itself to the sector of renewable energy especially PV. Some of these activities are also described in the paper

  8. From irradiance to output power fluctuations: the pv plant as a low pass filter

    OpenAIRE

    de Marcos, Javier; Marroyo, Luis; Lorenzo Pigueiras, Eduardo; Alvira, David; Izco, Eloisa

    2011-01-01

    The power generated by large grid-connected photovoltaic (PV) plants depends greatly on the solar irradiance. This paper studies the effects of the solar irradiance variability analyzing experimental 1-s data collected throughout a year at six PV plants, totaling 18 MWp. Each PV plant was modeled as a first order filter function based on an analysis in the frequency domain of the irradiance data and the output power signals. An empiric expression which relates the filter parameters and the PV...

  9. Hybrid PV/T solar systems for domestic hot water and electricity production

    International Nuclear Information System (INIS)

    Hybrid photovoltaic/thermal (PV/T) solar systems can simultaneously provide electricity and heat, achieving a higher conversion rate of the absorbed solar radiation than standard PV modules. When properly designed, PV/T systems can extract heat from PV modules, heating water or air to reduce the operating temperature of the PV modules and keep the electrical efficiency at a sufficient level. In this paper, we present TRNSYS simulation results for hybrid PV/T solar systems for domestic hot water applications both passive (thermosyphonic) and active. Prototype models made from polycrystalline silicon (pc-Si) and amorphous silicon (a-Si) PV module types combined with water heat extraction units were tested with respect to their electrical and thermal efficiencies, and their performance characteristics were evaluated. The TRNSYS simulation results are based on these PV/T systems and were performed for three locations at different latitudes, Nicosia (35 deg.), Athens (38 deg.) and Madison (43 deg.). In this study, we considered a domestic thermosyphonic system and a larger active system suitable for a block of flats or for small office buildings. The results show that a considerable amount of thermal and electrical energy is produced by the PV/T systems, and the economic viability of the systems is improved. Thus, the PVs have better chances of success especially when both electricity and hot water is required as in domestic applications

  10. In-depth analysis on R and D investment and strategy on PV in South Korea

    International Nuclear Information System (INIS)

    Photovoltaics (PV) is an eco-friendly and green technology, as a renewable energy source, with the aim of minimizing carbon dioxide emission into the atmosphere. The Korean government has financed various domestic installations as well as research and development (R and D) programs to enter and develop a lead in the worldwide PV market. In this study, R and D investments in the area of PV are analyzed in terms of the respective ministry, performer, research characteristics, PV materials and output levels in detail. The Korean government in the Fiscal year (FY) 2010 provided $178 million dollars from R and D funds for PV development. 74% of the R and D funds in the context of PV has been invested by the Ministry of Knowledge Economy (MKE). Expenditures for R and D programs in terms of PV are mainly funded by small-medium companies (40%), and the portion of the R and D investment in crystalline silicon solar cells is the highest in terms of materials. In spite of the high levels of R and D investment in PV, the output for commercialization was relatively lower compared to the R and D input in FY 2009–2010. With these results, we suggested to develop various solutions to improve the R and D investment efficiency for PV technology in Korea

  11. Pyranometers and Reference Cells: Part 2: What Makes the Most Sense for PV Power Plants?; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Meydbray, J.; Riley, E.; Dunn, L.; Emery, K.; Kurtz, S.

    2012-10-01

    As described in Part 1 of this two-part series, thermopile pyranometers and photovoltaic (PV) reference cells can both be used to measure irradiance; however, there are subtle differences between the data that are obtained. This two-part article explores some implications of uncertainty and subtleties of accurately measuring PV efficiency in the field. Part 2 of the series shows how reference cells can be used to more confidently predict PV performance, but how this could best be accomplished if historic irradiance data could be available in PV-technology-specific formats.

  12. Comparison of existing PV models and possible integration under EU grid specifications

    OpenAIRE

    THEOLOGITIS Ioannis-Thomas

    2011-01-01

    This master thesis investigates the capabilities of a generic grid-connected photovoltaic (PV) model that was developed by DIgSILENT and is part of the library of the new version of PowerFactory v.14.1. The model has a nominal rated peak power of 0.5 MVA and a designed power factor cosφ=0.95. A static generator component, which includes the PV array, the DC bus with the capacitor, the inverter and the control frame, is used to model the PV system. The PV array is considered to operate at the ...

  13. Intelligent control of PV system on the basis of the fuzzy recurrent neuronet*

    Science.gov (United States)

    Engel, E. A.; Kovalev, I. V.; Engel, N. E.

    2016-04-01

    This paper presents the fuzzy recurrent neuronet for PV system’s control. Based on the PV system’s state, the fuzzy recurrent neural net tracks the maximum power point under random perturbations. The validity and advantages of the proposed intelligent control of PV system are demonstrated by numerical simulations. The simulation results show that the proposed intelligent control of PV system achieves real-time control speed and competitive performance, as compared to a classical control scheme on the basis of the perturbation & observation algorithm.

  14. Two-Stage Fault Diagnosis Method Based on the Extension Theory for PV Power Systems

    OpenAIRE

    Meng-Hui Wang; Mu-Jia Chen

    2012-01-01

    In order to shorten the maintenance time and make sure of the photovoltaic (PV) power generation system steadily in operation, a fault diagnosis system for photovoltaic power generation system was proposed in this paper. First, a PSIM software is used to simulate a 2.2 kW PV system, it can take the operating date of the PV system under different sunlight intensity and temperature conditions. In this paper, a two-stage diagnosis system based on the extension theory for PV power systems is prop...

  15. Precursor Report of Data Needs and Recommended Practices for PV Plant Availability Operations and Maintenance Reporting.

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Roger R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Balfour, John R. [High Performance PV, Phoenix, AZ (United States)

    2015-01-01

    Characterizing the factors that affect reliability of a photovoltaic (PV) power plant is an important aspect of optimal asset management. This document describes the many factors that affect operation and maintenance (O&M) of a PV plant, identifies the data necessary to quantify those factors, and describes how data might be used by O&M service providers and others in the PV industry. This document lays out data needs from perspectives of reliability, availability, and key performance indicators and is intended to be a precursor for standardizing terminology and data reporting, which will improve data sharing, analysis, and ultimately PV plant performance.

  16. The feasibility of a batteryless PV powered vaccine fridge

    Energy Technology Data Exchange (ETDEWEB)

    Gwillim, J.; Polack, P.; Marks, K.

    2002-07-01

    An investigation into the feasibility of a batteryless PV-powered refrigerator for storing vaccines was undertaken by Dulas Ltd, Lec plc. Such a device would be valuable in places with no mains supply of electric power. Four criteria to be satisfied were listed. The work was undertaken as three phases: (i) consideration of materials and design; (ii) practical evaluation of the theoretical models; (iii) development of a test bed; and (iv) testing the system. A feature of the system was the use of phase change material rather than lead acid batteries for energy storage.

  17. Shell makes big solar PV push in South Africa

    International Nuclear Information System (INIS)

    This article highlights the launch of a joint initiative in South Africa with Shell International Renewables (SIR) to be electricity to homes in the Eastern Cape Province which has enabled SIR to increase its share of the South African market for photovoltaic (PV) systems. Details are given of the Shell manufactured 'Powerhouse' system comprising a solar cell linked to a pre-payment meter, which is leased to the homeowner at the same cost as they are already paying for batteries, candles, kerosene etc. The market structure for the Powerhouse system, the provision of power for householders, and the commitment to the major electrification programme are discussed

  18. Design of Cuk Converter Powered by PV Array

    Directory of Open Access Journals (Sweden)

    S. Jayalalitha

    2013-06-01

    Full Text Available This study presents PV power based cuk converter for dc load application. The maximum power from the sun radiation is obtained by sun tracking and Maximum Power Point Tracking (MPPT. The sun tracking is implemented by the stepper motor control and MPPT is implemented by the Cuk converter and the load voltage is maintained constant irrespective of the variation in solar power. This technique improves the dynamic and steady state characteristics of the system. The simulation was done in MATLAB simulink and the experiments are carried out and the results are presented.

  19. PV power and profit? Electrifying rural South Africa

    International Nuclear Information System (INIS)

    This article traces the background to the implementation of a programme of sustainable off-grid energy services delivered to rural areas through private-public partnership. The implementation of the school photovoltaic (PV) electrification programme, electrification of rural clinics, the solar electrification of rural households on a large scale through a joint venture between Shell Renewables and the national utility ESKOM, and the electrification of widely scattered homesteads are discussed. Details are given of the financial support from the government and the National Electricity Regulator, the development of a national standard for Solar Home Systems, identification of target regions, the regulatory framework, and the opportunities for business and for real improvement. (UK)

  20. 5bv.3.21 PV led engine

    DEFF Research Database (Denmark)

    Thorsteinsson, Sune; Poulsen, Peter Behrensdorff; Dam-Hansen, Carsten;

    PV-powered lighting systems, light to light systems (L2L), offer outdoor lighting where it is elsewhere cumbersome to enable lighting. Application of these systems at high latitudes, where the difference in day length between summer and winter is large and the solar energy is less requires smart...... dimming functions for reliable lighting.In this work we have build a laboratory to characterize these systems up to 200 WP from “nose totail” in great detail to support improvement of the systems and to make accurate field performance predictions....

  1. Comparison of PV system design software packages for urban applications

    Energy Technology Data Exchange (ETDEWEB)

    Gharakhani Siraki, Arbi; Pillay, Pragasen

    2010-09-15

    A large number of software packages are available for solar resource evaluation and PV system design. However, few of them are suitable for urban applications. In this paper a comparison has been made between two specifically designed solar tools known as the Ecotect 2010 and the PVsyst 5.05. Conclusions have been made for proper use of these packages based on their specifications and privileges. Moreover, the calculations have been repeated with HOMER software package (which is a generic tool) for the same location. The results suggest that a generic solar software tool should not be used for an urban application.

  2. The effect of sandstorms on PV arrays and components

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, J P

    1992-03-01

    Photovoltaic (PV) systems deployed in desert areas are exposed to wind-blown particles during most of their lifetimes. Here I describe the characteristics of wind-blown particles and with their effect on exposed surfaces. I provide insights for use in array design to minimize the effects of exposure and keep system costs as low as possible. Finally, I present some data describing the exposure of polymer-encapsulated arrays to both field and laboratory wind-blown sand environments, and I present evidence that an encapsulated or soft'' array has a higher abrasion resistance and, therefore, a much higher probability of surviving a severe sand environment.

  3. Weather modeling and forecasting of PV systems operation

    CERN Document Server

    Paulescu, Marius; Gravila, Paul; Badescu, Viorel

    2012-01-01

    In the past decade, there has been a substantial increase of grid-feeding photovoltaic applications, thus raising the importance of solar electricity in the energy mix. This trend is expected to continue and may even increase. Apart from the high initial investment cost, the fluctuating nature of the solar resource raises particular insertion problems in electrical networks. Proper grid managing demands short- and long-time forecasting of solar power plant output. Weather modeling and forecasting of PV systems operation is focused on this issue. Models for predicting the state of the sky, nowc

  4. Optical investigation of a sun simulator for concentrator PV applications.

    Science.gov (United States)

    Rapp, Christoph; Straub, Volker; van Rooyen, De Wet; Thor, Wei Yi; Siefer, Gerald; Bett, Andreas W

    2015-09-21

    In photovoltaics (PV), sun simulators are used to reproduce outdoor conditions in a lab environment such as irradiance level, light uniformity and spectral distribution. Concentrator (C)PV applications additionally require the sun simulators to provide rays with an angular distribution similar to that of the sun rays. However, different factors in CPV sun simulator setups make it difficult to achieve the perfect sun like angular distribution. This is mainly caused by the unavailability of appropriate light sources. Therefore, we investigated in this work, to which deviations such a non-ideal light source can lead and which impact is expected at the measurement of a CPV module. For this, two ray tracing models are presented - one for the simulation of natural sunrays, another one for the simulation of sun simulator conditions. The models are validated based on measurements and subsequently used to simulate the impact on a typical CPV module with silicone-on-glass Fresnel lenses. Here, significant deviations to outdoor conditions are found. PMID:26406756

  5. Temperature Dependences on Various Types of Photovoltaic (PV) Panel

    Science.gov (United States)

    Audwinto, I. A.; Leong, C. S.; Sopian, K.; Zaidi, S. H.

    2015-09-01

    Temperature is one of the key roles in PV technology performance, since with the increases of temperature the open-circuit voltage will drop accordingly so do the electrical efficiency and power output generation. Different types of Photovoltaic (PV) panels- silicon solar panels and thin film solar panels; mono-crystalline, poly-crystalline, CIS, CIGS, CdTe, back-contact, and bi-facial solar panel under 40°C to 70°C approximately with 5°C interval have been comparatively analyzed their actual performances with uniformly distribution of light illumination from tungsten halogen light source, ±500W/m2. DC-Electronic Load and Data Logger devices with “Lab View” data program interface were used to collect all the necessary parameters in this study. Time needed to achieve a certain degree of temperature was recorded. Generally, each of the panels needed 15 minutes to 20 minutes to reach 70°C. Halogen based light source is not compatible in short wave-length in response to thin-film solar cell. Within this period of times, all the panels are facing a performance loss up to 15%. Other parameters; Pmax, Vmax, Imax, Voc, Isc, Rserries, Rshunt, Fillfactor were collected as study cases. Our study is important in determining Photovoltaic type selection and system design as for study or industrial needed under different temperature condition.

  6. A control strategy for PV stand-alone applications

    Science.gov (United States)

    Slouma, S.; Baccar, H.

    2015-04-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.

  7. Sizing and Simulation of PV-Wind Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Mustafa Engin

    2013-01-01

    Full Text Available A sizing procedure is developed for hybrid system with the aid of mathematical models for photovoltaic cell, wind turbine, and battery that are readily present in the literature. This sizing procedure can simulate the annual performance of different kinds of photovoltaic-wind hybrid power system structures for an identified set of renewable resources, which fulfills technical limitations with the lowest energy cost. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Security lightning application is selected, whereas system performance data and environmental operating conditions are measured and stored. This hybrid system, which includes a PV, wind turbine, inverter, and a battery, was installed to supply energy to 24 W lamps, considering that the renewable energy resources of this site where the system was installed were 1700 Wh/m2/day solar radiation and 3.43 m/s yearly average wind speed. Using the measured variables, the inverter and charge regulator efficiencies were calculated as 90% and 98%, respectively, and the overall system’s electrical efficiency is calculated as 72%. Life cycle costs per kWh are found to be $0.89 and LLP = 0.0428.

  8. Hydrogen Production from Optimal Wind-PV Energies Systems

    Energy Technology Data Exchange (ETDEWEB)

    T Tafticht; K Agbossou [Institut de recherche sur l hydrogene, Universite du Quebec - Trois-Rivieres, C.P. 500, Trois-Rivieres, (Ciheam), G9A 5H7, (Canada)

    2006-07-01

    Electrolytic hydrogen offers a promising alternative for long-term energy storage of renewable energies (RE). A stand-alone RE system based on hydrogen production has been developed at the Hydrogen Research Institute and successfully tested for automatic operation with designed control devices. The system is composed of a wind turbine, a photovoltaic (PV) array, an electrolyzer, batteries for buffer energy storage, hydrogen and oxygen storage tanks, a fuel cell, AC and DC loads, power conditioning devices and different sensors. The long-term excess energy with respect to load demand has been sent to the electrolyser for hydrogen production and then the fuel cell has utilised this stored hydrogen to produce electricity when there were insufficient wind and solar energies with respect to load requirements. The RE system components have substantially different voltage-current characteristics and they are integrated on the DC bus through power conditioning devices for optimal operation by using the developed Maximum Power Point Tracking (MPPT) control method. The experimental results show that the power gain obtained by this method clearly increases the hydrogen production and storage rate from wind-PV systems. (authors)

  9. Hydrogen Production from Optimal Wind-PV Energies Systems

    Energy Technology Data Exchange (ETDEWEB)

    Tafticht, T.; Agbossou, K. [Institut de recherche sur l hydrogene, Universite du Quebec - Trois-Rivieres, C.P. 500, Trois-Rivieres, (Ciheam), G9A 5H7, (Canada)

    2006-07-01

    Electrolytic hydrogen offers a promising alternative for long-term energy storage of renewable energies (RE). A stand-alone RE system based on hydrogen production has been developed at the Hydrogen Research Institute and successfully tested for automatic operation with designed control devices. The system is composed of a wind turbine, a photovoltaic (PV) array, an electrolyser, batteries for buffer energy storage, hydrogen and oxygen storage tanks, a fuel cell, AC and DC loads, power conditioning devices and different sensors. The long-term excess energy with respect to load demand has been sent to the electrolyser for hydrogen production and then the fuel cell has utilised this stored hydrogen to produce electricity when there were insufficient wind and solar energies with respect to load requirements. The RE system components have substantially different voltage-current characteristics and they are integrated on the DC bus through power conditioning devices for optimal operation by using the developed Maximum Power Point Tracking (MPPT) control method. The experimental results show that the power gain obtained by this method clearly increases the hydrogen production and storage rate from wind-PV systems. (authors)

  10. Hydrogen Production from Optimal Wind-PV Energies Systems

    International Nuclear Information System (INIS)

    Electrolytic hydrogen offers a promising alternative for long-term energy storage of renewable energies (RE). A stand-alone RE system based on hydrogen production has been developed at the Hydrogen Research Institute and successfully tested for automatic operation with designed control devices. The system is composed of a wind turbine, a photovoltaic (PV) array, an electrolyser, batteries for buffer energy storage, hydrogen and oxygen storage tanks, a fuel cell, AC and DC loads, power conditioning devices and different sensors. The long-term excess energy with respect to load demand has been sent to the electrolyser for hydrogen production and then the fuel cell has utilised this stored hydrogen to produce electricity when there were insufficient wind and solar energies with respect to load requirements. The RE system components have substantially different voltage-current characteristics and they are integrated on the DC bus through power conditioning devices for optimal operation by using the developed Maximum Power Point Tracking (MPPT) control method. The experimental results show that the power gain obtained by this method clearly increases the hydrogen production and storage rate from wind-PV systems. (authors)

  11. An Accurate ANFIS-based MPPT for Solar PV System

    Directory of Open Access Journals (Sweden)

    Ahmed Bin-Halabi

    2014-06-01

    Full Text Available It has been found from the literature review that the ANFIS-based maximum power point tracking (MPPT techniques are very fast and accurate in tracking the MPP at any weather conditions, and they have smaller power losses if trained well. Unfortunately, this is true in simulation, but in practice they do not work very well because they do not take aging of solar cells as well as the effect of dust and shading into account. In other words, the solar irradiance measured by solar irradiance sensor is not always the same irradiance that influences the PV module. The main objective of this work is to design and practically implement an MPPT system for solar PV with high speed, high efficiency, and relatively easy implementation in order to improve the efficiency of solar energy conversion. This MPPT system is based on ANFIS technique. The contribution of this research is eliminating the need of irradiance sensor while having the same adequate performance obtained by the ANFIS with irradiance sensor, both, in simulation as well as in experimental implementation. The proposed technique has been validated by comparing the practical results of the implemented setup to simulations. Experimental results have showed good agreement with simulation results.

  12. Approaches to improving energy yield from PV modules

    Science.gov (United States)

    Jaus, Joachim; Duell, Matthias; Eckert, Johannes; Adurodija, Frederick O.; Li, Biao; Mickiewicz, Rafal A.; Doble, Dan M.

    2010-08-01

    PV modules were fabricated that incorporated various methods to increase the amount of light which is ultimately transmitted to the solar cell in order to improve energy yield. The techniques employed included diffuse scattering and reflection to minimize shading losses, as well as using structured glass to increase the probability of incident light capture. In the first technology, a laser is used to create a scattering pattern on the front-side glass of the module. This pattern directed light away from the bus bars and grid fingers, resulting in an increase in short circuit current (ISC) of up to 3.3%. In the second technology, the bus wires were coated with a diffuse reflective coating. A part of the incident sunlight is reflected from this coating at such angles that internal reflection at the front surface of the front-side glass occurs. The light is reflected back to the active area of the solar cell and contributes to the generated photocurrent resulting in an average increase of 0.9% in ISC. Finally, four different types of commercially available structured glass were investigated: grooves, pyramids, inverted pyramids, and a very lightly textured glass with only 5% increased surface area. Results showed an increase in ISC of up to 3.2% for pyramid structures using normally incident light, with the effect increasing at higher angles of incidence. The results demonstrated the possibility of improving PV module energy yield by taking advantage of basic optical principles and straightforward processing methods.

  13. Islanding Issues of Grid-connected PV Systems

    Directory of Open Access Journals (Sweden)

    S.Narendiran

    2013-04-01

    Full Text Available ‘Islanding’ is a term, which refers to the situation when the Distributed generator (DG continues to power the consumer-end even when the electrical power from the electric utility is no longerpresent. Islanding phenomenon occurs after the certain part of the utility grid gets disconnected from a large number of inter-connected PVs. It leads to troubles in voltage and frequency control and powerquality issues. Therefore there is a need for appropriate anti-islanding measures for grid-connected PV systems. There are two ways to defeat the islanding phenomenon, by reactor insertion method on utility side and capacitor insertion method on PV side. Some of the Islanding detection methods (IDMs are broadly classifies as Active, Passive and Utility based. Active mode of detection includes impedance measurement, slip mode frequency shift and frequency bias. Passive methods contain over/under voltage and frequency and harmonics detection. Utility-based methods consist of manual disconnection, SCADA, impedance insertion.

  14. Centre for Interactive Research on Sustainability : integration of PV

    Energy Technology Data Exchange (ETDEWEB)

    Cole, R.J. [British Columbia Univ., Vancouver, BC (Canada). School of Architecture and Landscape Architecture; Cayuela, A.; McCarry, B. [Stantec Consulting Ltd., Surrey, BC (Canada); Robinson, J. [British Columbia Univ., Vancouver, BC (Canada); Tabatabaian, M.; Yen, D. [British Columbia Institute of Technology, Burnaby, BC (Canada)

    2007-07-01

    This paper provided details of the building-integrated photovoltaic (BIPV) system designed for the Centre for Interactive Research on Sustainability (CIRS). The centre will be used as a research vehicle for the assessment and monitoring of sustainable building products and practices. The BIPV will occupy an area of 170 m{sup 2}, and will encompass the south-facing modules of an atrium skylight saw-tooth. Installed capacity of the system will be 23 kWp. The tilt angle of the south-facing part of the skylight will be 30 degrees. Real time monitoring and display of the energy provided by the BIPV is expected to provide feedback for the researchers and allow the public to gain a better understanding of its operation. The BIPV was designed to be a net producer of energy for the centre and is one of several clean energy strategies that will be used to ensure that the centre remains carbon neutral. The design of the PV system and its overall transparently will ensure that the centre uses 100 per cent daylighting. Rainwater will also be collected on the PV surfaces. The BIPV will be monitored as part of a research program developing anticipatory-predictive control algorithms for solar-optimized buildings, and was designed to be accessible to the public. It was concluded that the BIPV system will lead to greater public and industry acceptance of solar technology. 7 refs., 2 tabs., 7 figs.

  15. Energy management for a PEMFC–PV hybrid system

    International Nuclear Information System (INIS)

    Highlights: • The proposed hybrid structure is a grid-connected system composed of a PV panel, a FC, a battery, and a SC. • The output voltage of each component is regulated using a buck converter controlled by a type-III compensator. • All these components share one DC bus. • Loads can be the used battery, the grid, a DC load and/or an AC load. • The proposed topology offers a simple management technique using a low cost system controller. - Abstract: Most renewable energy sources depend on climatic circumstances and lack consistency even during a single day. The Hybrid System (HS) solves this drawback by relying on many types of renewable sources and managing them to get a satisfactory continuous power. In this paper, a grid connected HS composed of a Proton Exchange Membrane Fuel Cell (PEMFC), a Photovoltaic panel (PV), a battery and a Supercapacitor (SC) is proposed. Sources are pushed to deliver their maximum power thanks to a Maximum Power Point Tracker (MPPT). The output voltage of each component is regulated using a buck converter controlled by a type-III compensator. Consequently, HS components share the power on a single DC bus. The proposed topology offers a simple management technique using an affordable system controller. In order to illustrate our approach, a prototype is modeled, simulated and implemented on an emulator of a real system

  16. Fire risk related to the use of PV systems in building facades

    Directory of Open Access Journals (Sweden)

    Mazziotti Lamberto

    2016-01-01

    Full Text Available Nowadays the use of photovoltaic (PV systems in buildings is not only related to the solar energy conversion into electrical one, but these PV modules or panels could also be used with aesthetic features or, even more, as thermal protection systems in building facades. Thanks to the technical development of the photovoltaic industry, PV system can easily be architectonically integrated into building construction elements such as roofs, vertical façade components, both with opaque or transparent surfaces. Furthermore, PV construction facades elements could also be provided by openings like doors or windows. Accident analysis show that the use of PV systems as construction elements could increase the risk of fire in buildings. In fact, international and National data report a growing number of fire caused by PV system applied or integrated in buildings. The Italian National Fire Service, that is the Authority having jurisdiction for fire safety in buildings (in Italy, in 2012 has released a Guideline in order to asses and mitigate the risk of fire when a PV system is put in place on a building as a façade or as a roof. The Guideline addresses not only the reduction of the PV fire ignitions causes and the aspects related to the fire spread due to the combustible parts that constitute PV modules or panels, but also take into account the safety of both the maintenance personnel and the rescue teams. This paper focuses on the fire safety aspects related to the use of fire PV panels and systems in building facades, showing some interesting experimental data related to the fire behaviour of these components and underlining the factors that promote the spread of fire, like the high operating temperature of the PV system itself.

  17. Future of Grid-Tied PV Business Models: What Will Happen When PV Penetration on the Distribution Grid is Significant? Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Graham, S.; Katofsky, R.; Frantzis, L.; Sawyer, H.; Margolis, R.

    2008-05-01

    Eventually, distributed PV will become a more significant part of the generation mix. When this happens, it is expected that utilities will have to take on a more active role in the placement, operation and control of these systems. There are operational complexities and concerns of revenue erosion that will drive utilities into greater involvement of distributed PV and will create new business models. This report summarizes work done by Navigant Consulting Inc. for the National Renewable Energy Laboratory as part of the Department of Energy's work on Renewable System Integration. The objective of the work was to better understand the structure of these future business models and the research, development and demonstration (RD&D) required to support their deployment. This report describes potential future PV business models in terms of combinations of utility ownership and control of the PV assets, and the various relationships between end-users and third-party owners.

  18. Genomic-associated Markers and comparative Genome Maps of Xanthomonas oryzae pv. oryzae and X. oryzae pv. oryzicola.

    Science.gov (United States)

    Feng, Wenjie; Wang, Yi; Huang, Lisha; Feng, Chuanshun; Chu, Zhaohui; Ding, Xinhua; Yang, Long

    2015-09-01

    Xanthomonas oryzae pv. oryzae (Xoo) and X. oryzae pv. oryzicola (Xoc) cause two major seed quarantine diseases in rice, bacterial blight and bacterial leaf streak, respectively. Xoo and Xoc share high similarity in genomic sequence, which results in hard differentiation of the two pathogens. Genomic-associated Markers and comparative Genome Maps database (GMGM) is an integrated database providing comprehensive information including compared genome maps and full genomic-coverage molecular makers of Xoo and Xoc. This database was established based on bioinformatic analysis of complete sequenced genomes of several X. oryzae pathovars of which the similarity of the genomes was up to 91.39 %. The program was designed with a series of specific PCR primers, including 286 pairs of Xoo dominant markers, 288 pairs of Xoc dominant markers, and 288 pairs of Xoo and Xoc co-dominant markers, which were predicted to distinguish two pathovars. Test on a total of 40 donor pathogen strains using randomly selected 120 pairs of primers demonstrated that over 52.5 % of the primers were efficacious. The GMGM web portal ( http://biodb.sdau.edu.cn/gmgm/ ) will be a powerful tool that can present highly specific diagnostic markers, and it also provides information about comparative genome maps of the two pathogens for future evolution study. PMID:26093644

  19. Distribution System Augmented by DC Links for Increasing the Hosting Capacity of PV Generation

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Demirok, Erhan; Teodorescu, Remus

    2012-01-01

    This paper presents a concept of enhancing the photovoltaic (PV) power generation hosting capacity of distribution networks. Distribution network serving electrical energy to farm settlements was selected as an example for their large roof area available for PV installation. Further, they are...

  20. Sensor System for Long-term Recording of Photovoltaic (PV) IV-curves

    DEFF Research Database (Denmark)

    Paasch, Kasper; Nymand, Morten; Haase, Frerk

    2013-01-01

    The purpose of this paper is to present a recording system for long-term investigation of PV panel dynamics under partial shading conditions. The system is intended to be a low-cost system deployable for stand-alone field use and long-term data recording at PV-plants. Passing clouds will affect the...

  1. Distributed measurement system for long term monitoring of clouding effects on large PV plants

    DEFF Research Database (Denmark)

    Paasch, K. M.; Nymand, M.; Haase, F.

    2013-01-01

    A recording system for the generation of current-voltage characteristics of solar panels is presented. The system is intended for large area PV power plants. The recorded curves are used to optimize the energy output of PV power plants, which are likely to be influenced by passing clouds and...

  2. Simulation Model developed for a Small-Scale PV-System in a Distribution Network

    DEFF Research Database (Denmark)

    Koch-Ciobotaru, C.; Mihet-Popa, Lucian; Isleifsson, Fridrik Rafn;

    2012-01-01

    This paper presents a PV panel simulation model using the single-diode four-parameter model based on data sheet values. The model was implemented first in MATLAB/Simulink, and the results have been compared with the data sheet values and characteristics of the PV panels in standard test conditions...

  3. Effect of Reactive Power Management of PV Inverters on Need for Energy Storage

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Yang, Guangya

    2013-01-01

    Grid connected Photovoltaic (PV) systems are among the increasingly growing electric power generation units worldwide. The majority of new installations are expected to be residential PVs that are connected into distribution systems. However, the PV hosting capacity of low voltage (LV) grids is...

  4. Effective information channels for reducing costs of environmentally- friendly technologies: evidence from residential PV markets

    International Nuclear Information System (INIS)

    Realizing the environmental benefits of solar photovoltaics (PV) will require reducing costs associated with perception, informational gaps and technological uncertainties. To identify opportunities to decrease costs associated with residential PV adoption, in this letter we use multivariate regression models to analyze a unique, household-level dataset of PV adopters in Texas (USA) to systematically quantify the effect of different information channels on aspiring PV adopters’ decision-making. We find that the length of the decision period depends on the business model, such as whether the system was bought or leased, and on special opportunities to learn, such as the influence of other PV owners in the neighborhood. This influence accrues passively through merely witnessing PV systems in the neighborhood, increasing confidence and motivation, as well as actively through peer-to-peer communications. Using these insights we propose a new framework to provide public information on PV that could drastically reduce barriers to PV adoption, thereby accelerating its market penetration and environmental benefits. This framework could also serve as a model for other distributed generation technologies. (letter)

  5. Common mode voltage in case of transformerless PV inverters connected to the grid

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco

    2008-01-01

    For safety reasons grid connected PV systems include galvanic isolation. In case of transformerless inverters, the leakage ground current through the parasitic capacitance of the PV panels, can reach very high values. A common-mode model based on analytical approach is introduced, used to predict...

  6. Effective information channels for reducing costs of environmentally- friendly technologies: evidence from residential PV markets

    Science.gov (United States)

    Rai, Varun; Robinson, Scott A.

    2013-03-01

    Realizing the environmental benefits of solar photovoltaics (PV) will require reducing costs associated with perception, informational gaps and technological uncertainties. To identify opportunities to decrease costs associated with residential PV adoption, in this letter we use multivariate regression models to analyze a unique, household-level dataset of PV adopters in Texas (USA) to systematically quantify the effect of different information channels on aspiring PV adopters’ decision-making. We find that the length of the decision period depends on the business model, such as whether the system was bought or leased, and on special opportunities to learn, such as the influence of other PV owners in the neighborhood. This influence accrues passively through merely witnessing PV systems in the neighborhood, increasing confidence and motivation, as well as actively through peer-to-peer communications. Using these insights we propose a new framework to provide public information on PV that could drastically reduce barriers to PV adoption, thereby accelerating its market penetration and environmental benefits. This framework could also serve as a model for other distributed generation technologies.

  7. Optimization of a PV/T (photovoltaic/thermal) active solar still

    International Nuclear Information System (INIS)

    In this paper, the optimization of a PV/T (photovoltaic/thermal) active solar still is carried out. Analytical expressions for glass cover temperature, basin temperature, brackish water temperature and fresh water productivity are obtained by writing energy balance for different components of PV/T active solar still. The output electrical power of PV/T active solar still is calculated by four-parameter I–V (current–voltage) model. Objective function in present study is the energy efficiency of PV/T active solar still. A computer simulation program has been developed in order to obtain thermal and electrical parameters, respectively. The simulation results of the present study are in fair agreement with the experimental data of previous literatures. Finally, the optimization of PV/T active solar still has been carried out and the optimized value of mass flow rate, number of PV/T collector and the objective function have been obtained. Furthermore, the effect of various operating parameters on energy efficiency have been investigated. - Highlights: • The comprehensive optimization of a PV/T active solar still is carried out. • Present study is based on numerical simulation. • A modified energy efficiency for PV/T active solar still is obtained. • The effect of design and operating parameters is investigated on energy efficiency

  8. Storage Application in Smart Grid with High PV and EV Penetration

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Yang, Guangya; Østergaard, Jacob; You, Shi; Cha, Seung-Tae

    2013-01-01

    grids with residential PVs and Electric Vehicles (EVs). The effect of EV home charging on EESS capacity in high PV penetration is also addressed. The results indicate that increasing the EV penetration in the network can decrease the EESS capacity need. This decrease is highest in situations with low PV...

  9. Experimental validation of a probabilistic model for estimating the double axis PV tracking energy production

    International Nuclear Information System (INIS)

    Highlights: ► PV system production evaluation will be a crucial issue to plan and operate future power networks. ► PV system power is a stochastic variable so a probabilistic approach can be used to model it. ► PV system efficiency is the main parameter in AC power (PAC) probability density function (PDF). ► Operating PV module temperature is the main variable in PV system efficiency. ► Efficiency models have been introduced in PDF of PAC and checked against real measured data. -- Abstract: This work aims to study the impact of different models for the evaluation of the efficiency of a double axis PV tracking system on the monthly probability distribution function of the AC power. Two components of the global efficiency are analysed, that is: the effect of PV cells temperature on the module efficiency and the DC/AC converter efficiency. In particular, the temperature efficiency model combines basic parameters characterizing the array, with the local monthly average temperature and the monthly clearness index to yield a monthly average efficiency. The simulation results are compared with experimental data related to a 9.6 kWp PV plant installed in ENEA research centre located in Portici, Naples (Italy). The tuning of the model is performed by both system measurements and environmental data.

  10. Irrigation water is an unlikely source of inoculum of Pseudomonas cannabina pv. alisalensis

    Science.gov (United States)

    Pseudomonas cannabina pv. alisalensis causes severe bacterial blight on crucifers across the United States. These experiments examined the potential of irrigation water as a source of inoculum for P. cannabina pv. alisalensis. Water samples were collected from multiple irrigation reservoirs and spri...

  11. Creating dynamic equivalent PV circuit models with impedance spectroscopy for arc-fault modeling.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean; Kuszmaul, Scott S.; Strauch, Jason E.; Schoenwald, David Alan

    2011-06-01

    Article 690.11 in the 2011 National Electrical Code{reg_sign} (NEC{reg_sign}) requires new photovoltaic (PV) systems on or penetrating a building to include a listed arc fault protection device. Currently there is little experimental or empirical research into the behavior of the arcing frequencies through PV components despite the potential for modules and other PV components to filter or attenuate arcing signatures that could render the arc detector ineffective. To model AC arcing signal propagation along PV strings, the well-studied DC diode models were found to inadequately capture the behavior of high frequency arcing signals. Instead dynamic equivalent circuit models of PV modules were required to describe the impedance for alternating currents in modules. The nonlinearities present in PV cells resulting from irradiance, temperature, frequency, and bias voltage variations make modeling these systems challenging. Linearized dynamic equivalent circuits were created for multiple PV module manufacturers and module technologies. The equivalent resistances and capacitances for the modules were determined using impedance spectroscopy with no bias voltage and no irradiance. The equivalent circuit model was employed to evaluate modules having irradiance conditions that could not be measured directly with the instrumentation. Although there was a wide range of circuit component values, the complex impedance model does not predict filtering of arc fault frequencies in PV strings for any irradiance level. Experimental results with no irradiance agree with the model and show nearly no attenuation for 1 Hz to 100 kHz input frequencies.

  12. Solar PV O&M Standards and Best Practices - Existing Gaps and Improvement Efforts

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Balfour, John R. [High Performance PV, Phoenix, AZ (United States); Keating, T. J. [SunSpec Alliance, San Jose, CA (United States)

    2014-11-01

    As greater numbers of photovoltaic (PV) systems are being installed, operations & maintenance (O&M) activities will need to be performed to ensure the PV system is operating as designed over its useful lifetime. To mitigate risks to PV system availability and performance, standardized procedures for O&M activities are needed to ensure high reliability and long-term system bankability. Efforts are just getting underway to address the need for standard O&M procedures as PV gains a larger share of U.S. generation capacity. Due to the existing landscape of how and where PV is installed, including distributed generation from small and medium PV systems, as well as large, centralized utility-scale PV, O&M activities will require different levels of expertise and reporting, making standards even more important. This report summarizes recent efforts made by solar industry stakeholders to identify the existing standards and best practices applied to solar PV O&M activities, and determine the gaps that have yet to be, or are currently being addressed by industry.

  13. CO2 Emissions of PV in the Perspective of a Renewable Energy Economy

    NARCIS (Netherlands)

    van Sark, W.G.J.H.M.; Reich, N.H.; Alsema, E.A.; Nieuwlaar, E.

    2007-01-01

    The wide range of greenhouse gas emissions (30-300 g CO2-eq/kWh) quoted for PV generated electricity in life cycle assessment studies so far is shown to be mainly caused by the different CO2 emission of energy consumed in manufacture of PV modules. A better way of comparing the CO2-eq emissions woul

  14. PV-wind hybrid system performance. A new approach and a case study

    Energy Technology Data Exchange (ETDEWEB)

    Arribas, Luis; Cano, Luis; Cruz, Ignacio [Departamento de Energias Renovables, CIEMAT, Avda. Complutense 22, 28040 Madrid (Spain); Mata, Montserrat; Llobet, Ermen [Ecotecnia, Roc Boronat 78, 08005 Barcelona (Spain)

    2010-01-15

    Until now, there is no internationally accepted guideline for the measurement, data exchange and analysis of PV-Wind Hybrid Systems. As there is a need for such a tool, so as to overcome the barrier that the lack of confidence due to the absence of reliability means for the development of the market of Hybrid Systems, an effort has been made to suggest one tool for PV-Wind Hybrid Systems. The suggested guidelines presented in this work are based on the existing guidelines for PV Systems, as a PV-Wind Hybrid system can be roughly thought of as a PV System to which wind generation has been added. So, the guidelines for PV Systems are valid for the PV-Wind System, and only the part referred to wind generation should be included. This has been the process followed in this work. The proposed method is applied to a case study, the CICLOPS Project, a 5 kW PV, 7.5 kW Wind Hybrid system installed at the Isolated Wind Systems Test Site that CIEMAT owns in CEDER (Soria, Spain). This system has been fully monitored through a year and the results of the monitoring activity, characterizing the long-term performance of the system are shown in this work. (author)

  15. Seroepidemiology of TmPV1 infection in captive and wild Florida manatees (Trichechus manatus latirostris).

    Science.gov (United States)

    Donà, Maria Gabriella; Rehtanz, Manuela; Adimey, Nicole M; Bossart, Gregory D; Jenson, Alfred B; Bonde, Robert K; Ghim, Shin-je

    2011-07-01

    In 1997, cutaneous papillomatosis caused by Florida manatee (Trichechus manatus latirostris [Tm]) papillomavirus 1 (TmPV1) was detected in seven captive manatees at the Homosassa Springs Wildlife State Park, Florida, USA, and, subsequently, in two wild manatees from the adjacent Homosassa River. Since then, papillomatosis has been reported in captive manatees housed in other locations, but not in wild animals. To determine TmPV1 antibody prevalence in captive and wild manatees sampled at various locations throughout Florida coastal regions, virus-like particles, composed of the L1 capsid protein of TmPV1, were generated with a baculovirus expression system and used to measure anti-TmPV1 antibodies in an enzyme-linked immunosorbent assay. Serologic analysis of 156 manatees revealed a TmPV1 antibody prevalence of 26.3%, with no significant difference between captive (n=39) and wild (n=117) manatees (28.2% and 25.6%, respectively). No antibody-positive wild animal showed PV-induced cutaneous lesions, whereas papillomatosis was observed in 72.7% of antibody-positive captive manatees. Our data indicate that Florida manatees living in the wild are naturally infected by TmPV1 but rarely show TmPV1-induced papillomatosis. Hence, it appears that the wild population would not be harmed in a case of contact with captive animals without visible lesions and productive infections, which could be thus released into the wild. PMID:21719832

  16. OUT Success Stories: Thin-Film PV: Leadership in Materials R and D

    International Nuclear Information System (INIS)

    Photovoltaics (PV) is a modern energy technology that makes use of semiconductor materials to convert sunlight directly to electricity. The idea of thin film technology is to produce truly low-cost PV devices by using pennies worth of active semiconductor materials

  17. Moving to a Higher Level for PV Reliability through Comprehensive Standards Based on Solid Science (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.

    2014-11-01

    PV reliability is a challenging topic because of the desired long life of PV modules, the diversity of use environments and the pressure on companies to rapidly reduce their costs. This presentation describes the challenges, examples of failure mechanisms that we know or don't know how to test for, and how a scientific approach is being used to establish international standards.

  18. Clustered PV Inverters in LV Networks: An Overview of Impacts and Comparison of Voltage Control Strategies

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus;

    2009-01-01

    High penetration of photovoltaic (PV) inverters in low voltage (LV) distribution network challenges the voltage stability due to interaction between multiple inverters and grid. As the main objective is to provide more power injection from VSC-based PV inverters, grid stability, reliability and p...

  19. Design and Operation Studies of A Stand-Alone PV Generation System

    DEFF Research Database (Denmark)

    Hu, Yanting; Chen, Zhe; Zhang, Donglai;

    2013-01-01

    This paper discusses the modeling, design and operation of a PV powered stand-alone system, which includes a PV array, a battery bank, power electronic converters and the associated control system. The design considerations are analyzed and a design platform is presented. Furthermore the operation...

  20. Computer Modelling and Simulation of Solar PV Array Characteristics

    Science.gov (United States)

    Gautam, Nalin Kumar

    2003-02-01

    The main objective of my PhD research work was to study the behaviour of inter-connected solar photovoltaic (PV) arrays. The approach involved the construction of mathematical models to investigate different types of research problems related to the energy yield, fault tolerance, efficiency and optimal sizing of inter-connected solar PV array systems. My research work can be divided into four different types of research problems: 1. Modeling of inter-connected solar PV array systems to investigate their electrical behavior, 2. Modeling of different inter-connected solar PV array networks to predict their expected operational lifetimes, 3. Modeling solar radiation estimation and its variability, and 4. Modeling of a coupled system to estimate the size of PV array and battery-bank in the stand-alone inter-connected solar PV system where the solar PV system depends on a system providing solar radiant energy. The successful application of mathematics to the above-m entioned problems entailed three phases: 1. The formulation of the problem in a mathematical form using numerical, optimization, probabilistic and statistical methods / techniques, 2. The translation of mathematical models using C++ to simulate them on a computer, and 3. The interpretation of the results to see how closely they correlated with the real data. Array is the most cost-intensive component of the solar PV system. Since the electrical performances as well as life properties of an array are highly sensitive to field conditions, different characteristics of the arrays, such as energy yield, operational lifetime, collector orientation, and optimal sizing were investigated in order to improve their efficiency, fault-tolerance and reliability. Three solar cell interconnection configurations in the array - series-parallel, total-cross-tied, and bridge-linked, were considered. The electrical characteristics of these configurations were investigated to find out one that is comparatively less susceptible to

  1. Wind effect on PV module temperature: Analysis of different techniques for an accurate estimation.

    Science.gov (United States)

    Schwingshackl, Clemens; Petitta, Marcello; Ernst Wagner, Jochen; Belluardo, Giorgio; Moser, David; Castelli, Mariapina; Zebisch, Marc; Tetzlaff, Anke

    2013-04-01

    In this abstract a study on the influence of wind to model the PV module temperature is presented. This study is carried out in the framework of the PV-Alps INTERREG project in which the potential of different photovoltaic technologies is analysed for alpine regions. The PV module temperature depends on different parameters, such as ambient temperature, irradiance, wind speed and PV technology [1]. In most models, a very simple approach is used, where the PV module temperature is calculated from NOCT (nominal operating cell temperature), ambient temperature and irradiance alone [2]. In this study the influence of wind speed on the PV module temperature was investigated. First, different approaches suggested by various authors were tested [1], [2], [3], [4], [5]. For our analysis, temperature, irradiance and wind data from a PV test facility at the airport Bolzano (South Tyrol, Italy) from the EURAC Institute of Renewable Energies were used. The PV module temperature was calculated with different models and compared to the measured PV module temperature at the single panels. The best results were achieved with the approach suggested by Skoplaki et al. [1]. Preliminary results indicate that for all PV technologies which were tested (monocrystalline, amorphous, microcrystalline and polycrystalline silicon and cadmium telluride), modelled and measured PV module temperatures show a higher agreement (RMSE about 3-4 K) compared to standard approaches in which wind is not considered. For further investigation the in-situ measured wind velocities were replaced with wind data from numerical weather forecast models (ECMWF, reanalysis fields). Our results show that the PV module temperature calculated with wind data from ECMWF is still in very good agreement with the measured one (R² > 0.9 for all technologies). Compared to the previous analysis, we find comparable mean values and an increasing standard deviation. These results open a promising approach for PV module

  2. A Best Practice for Developing Availability Guarantee Language in Photovoltaic (PV) O&M Agreements.

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Balfour, John [High Performance PV, Phoenix, AZ (United States)

    2015-11-01

    This document outlines the foundation for developing language that can be utilized in an Equipment Availability Guarantee, typically included in an O&M services agreement between a PV system or plant owner and an O&M services provider, or operator. Many of the current PV O&M service agreement Availability Guarantees are based on contracts used for traditional power generation, which create challenges for owners and operators due to the variable nature of grid-tied photovoltaic generating technologies. This report documents language used in early PV availability guarantees and presents best practices and equations that can be used to more openly communicate how the reliability of the PV system and plant equipment can be expressed in an availability guarantee. This work will improve the bankability of PV systems by providing greater transparency into the equipment reliability state to all parties involved in an O&M services contract.

  3. The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Nielsen, Kaspar Kirstein

    2015-01-01

    The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system is examined using an analytical model for four different types of commercial PVs and a commercial bismuth telluride TEG. The TEG is applied directly on the back of the PV, so that the two devices have ...... efficiency of the TEG. For c-Si, CIGS and CdTe PV cells the combined system produces a lower power and has a lower efficiency than the PV alone, whereas for an a-Si cell the total system performance may be slightly increased by the TEG....... the same temperature. The PVs considered are crystalline Si (c-Si), amorphous Si (a-Si), copper indium gallium (di) selenide (CIGS) and cadmium telluride (CdTe) cells. The degradation of PV performance with temperature is shown to dominate the increase in power produced by the TEG, due to the low...

  4. Influence of reflectance from flat aluminum concentrators on energy efficiency of PV/Thermal collector

    International Nuclear Information System (INIS)

    In this paper the results of the influence of reflectance from flat plate solar radiation concentrators made of Al sheet and Al foil on energy efficiency of PV/Thermal collector are presented. The total reflectance from concentrators made of Al sheet and Al foil is almost the same, but specular reflectance which is bigger in concentrators made of Al foil results in increase of solar radiation intensity concentration factor. With the increase of solar radiation intensity concentration factor, total daily thermal and electrical energy generated by PV/Thermal collector with concentrators increase. In this work also optimal position of solar radiation concentrators made of Al sheet and Al foil and appropriate thermal and electrical efficiency of PV/Thermal collector have been determined. Total energy generated by PV/Thermal collector with concentrators made of Al foil in optimal position is higher than total energy generated by PV/Thermal collector with concentrators made of Al sheet.

  5. The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system

    Science.gov (United States)

    Bjørk, R.; Nielsen, K. K.

    2015-10-01

    The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system is examined using an analytical model for four different types of commercial PVs and a commercial bismuth telluride TEG. The TEG is applied directly on the back of the PV, so that the two devices have the same temperature. The PVs considered are crystalline Si (c-Si), amorphous Si (a-Si), copper indium gallium (di)selenide (CIGS) and cadmium telluride (CdTe) cells. The degradation of PV performance with temperature is shown to dominate the increase in power produced by the TEG, due to the low efficiency of the TEG. For c-Si, CIGS and CdTe PV cells the combined system produces a lower power and has a lower efficiency than the PV alone, whereas for an a-Si cell the total system performance may be slightly increased by the TEG.

  6. Analysis of Photovoltaic (PV) Module during Partial Shading based on Simplified Two-Diode Model

    Science.gov (United States)

    Chitti Babu, B.; Gurjar, Suresh; Meher, Ashish

    2015-02-01

    Generally, the characteristics of photovoltaic (PV) array are largely affected by solar temperature, solar irradiance, shading patterns, array configuration and location of shading modules. Partial shading is due to moving clouds and shadows of nearby obstacles and can cause a significant degradation in the output of PV system. Hence, the characteristics of PV array get more multifaceted with multiple peaks. The ultimate aim of the paper is to analyze the performance of PV module during such adverse condition based on simplified two-diode model. To reduce the computational time, the simplified two-diode model has a photocurrent source in parallel with two ideal diodes. Only four parameters are required to be calculated from datasheet in order to simulate the model. Moreover, the performance of PV array is evaluated at different shaded patterns and it is found that the model has less computational time and gives accurate results.

  7. A Hybrid Power Control Concept for PV Inverters with Reduced Thermal Loading

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede;

    2014-01-01

    This letter proposes a hybrid power control concept for grid-connected Photovoltaic (PV) inverters. The control strategy is based on either a Maximum Power Point Tracking (MPPT) control or a Constant Power Generation (CPG) control depending on the instantaneous available power from the PV panels....... The essence of the proposed concept lies in the selection of an appropriate power limit for the CPG control to achieve an improved thermal performance and an increased utilization factor of PV inverters,and thus to cater for a higher penetration level of PV systems with intermittent nature. A case...... study on a single-phase PV inverter under yearly operation is presented with analyses of the thermal loading, lifetime, and annual energy yield. It has revealed the trade-off factors to select the power limit and also verified the feasibility and the effectiveness of the proposed control concept....

  8. Photovoltaic module V-I and P-V characterization through instrumentation control toolkit of MATLAB

    Directory of Open Access Journals (Sweden)

    Genci Sharko

    2011-11-01

    Full Text Available This paper describes one experimental method for determining the V-I and P-V characteristic of the photovoltaic modules. The short-circuit current (Isc, open-circuit voltage (Voc and the filling coefficient are measured, also. Direct characteristics of V-I and P-V curves under solar irradiance are measured and graphed in real time with system proposed for this reason. It describes the development of an automated monitoring system for a solar PV plant based on the use of Instrumentation Control Toolkit of MatLab Software. PV modules still have relatively low conversion efficiency; therefore, determining and controlling maximum power point tracking (MPPT for the solar array is essential in a PV system.

  9. Simplified Method for Modeling the Impact of Arbitrary Partial Shading Conditions on PV Array Performance: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    MacAlpine, Sara; Deline, Chris

    2015-09-15

    It is often difficult to model the effects of partial shading conditions on PV array performance, as shade losses are nonlinear and depend heavily on a system's particular configuration. This work describes and implements a simple method for modeling shade loss: a database of shade impact results (loss percentages), generated using a validated, detailed simulation tool and encompassing a wide variety of shading scenarios. The database is intended to predict shading losses in crystalline silicon PV arrays and is accessed using basic inputs generally available in any PV simulation tool. Performance predictions using the database are within 1-2% of measured data for several partially shaded PV systems, and within 1% of those predicted by the full, detailed simulation tool on an annual basis. The shade loss database shows potential to considerably improve performance prediction for partially shaded PV systems.

  10. Photovoltaic/thermal solar hybrid system with bifacial PV module and transparent plane collector

    Energy Technology Data Exchange (ETDEWEB)

    Robles-Ocampo, B. [Instituto Tecnologico de Celaya, Celaya 11111, Guanajuato (Mexico); CINVESTAV-Queretaro, Libramiento Norponiente 2000, Unidad Queretaro, Fracc. Real de Juriquilla, Queretaro, 76230, QRO (Mexico); Ruiz-Vasquez, E.; Canseco-Sanchez, H. [Instituto Tecnologico de Oaxaca, Oaxaca 68030, Oaxaca (Mexico); CINVESTAV-Queretaro, Libramiento Norponiente 2000, Unidad Queretaro, Fracc. Real de Juriquilla, Queretaro, 76230, QRO (Mexico); Cornejo-Meza, R.C. [Instituto Tecnologico de Tepic, av. Tecnologico 2595, Tepic 63175, Nayarit (Mexico); CINVESTAV-Queretaro, Libramiento Norponiente 2000, Unidad Queretaro, Fracc. Real de Juriquilla, Queretaro, 76230, QRO (Mexico); Trapaga-Martinez, G.; Vorobiev, Y.V. [CINVESTAV-Queretaro, Libramiento Norponiente 2000, Unidad Queretaro, Fracc. Real de Juriquilla, Queretaro, 76230, QRO (Mexico); Garcia-Rodriguez, F.J. [Instituto Tecnologico de Celaya, Celaya 11111, Guanajuato (Mexico); Gonzalez-Hernandez, J. [CIMAV, Miguel de Cervantes 120, Chihuahua 31109, Chihuahua (Mexico)

    2007-12-14

    Electric energy production with photovoltaic (PV)/thermal solar hybrid systems can be enhanced with the employment of a bifacial PV module. Experimental model of a PV/thermal hybrid system with such a module was constructed and studied. To make use of both active surfaces of the bifacial PV module, we designed and made an original water-heating planar collector and a set of reflecting planes. The heat collector was transparent in the visible and near-infrared spectral regions, which makes it compatible with the PV module made of crystalline Si. The estimated overall solar energy utilization efficiency for the system related to the direct radiation flux is of the order of 60%, with an electric efficiency of 16.4%. (author)

  11. The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system

    CERN Document Server

    Bjørk, R

    2015-01-01

    The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system is examined using an analytical model for four different types of commercial PVs and a commercial bismuth telluride TEG. The TEG is applied directly on the back of the PV, so that the two devices have the same temperature. The PVs considered are crystalline Si (c-Si), amorphous Si (a-Si), copper indium gallium (di)selenide (CIGS) and cadmium telluride (CdTe) cells. The degradation of PV performance with temperature is shown to dominate the increase in power produced by the TEG, due to the low efficiency of the TEG. For c-Si, CIGS and CdTe PV cells the combined system produces a lower power and has a lower efficiency than the PV alone, whereas for an a-Si cell the total system performance may be slightly increased by the TEG.

  12. Optimization of SiC-based H5 and Conergy-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    design technique is presented for optimizing the switching frequency and structure of the LCL-type output filter in transformerless H5 and Conergy-NPC PV inverters, which employ SiC-type power devices. The design optimization results demonstrate that the optimized SiC-based PV inverters are more......The transformerless DC/AC inverters are critical components in the rapidly growing market of grid-connected Photovoltaic (PV) applications. Also, the SiC-based power semiconductors are capable to operate reliably at high operating temperature and switches frequency levels. In this paper, a new...... effective in terms of energy production than their non-optimized and Si-based counterparts. Reducing the market price of SiC-type power semiconductors enables to design optimized PV inverters with a lower cost of energy than that of PV inverters employing Si technology, thus maximizing the economic...

  13. PV (photovoltaics) performance evaluation and simulation-based energy yield prediction for tropical buildings

    International Nuclear Information System (INIS)

    Air pollution and climate change increased the importance of renewable energy resources like solar energy in the last decades. Rack-mounted PhotoVoltaics (PV) and Building Integrated PhotoVoltaics (BIPV) are the most common photovoltaic systems which convert incident solar radiation on façade or surrounding area to electricity. In this paper the performance of different solar cell types is evaluated for the tropical weather of Singapore. As a case study, on-site measured data of PV systems implemented in a zero energy building in Singapore, is analyzed. Different types of PV systems (silicon wafer and thin film) have been installed on rooftop, façade, car park shelter, railing and etc. The impact of different solar cell generations, arrays environmental conditions (no shading, dappled shading, full shading), orientation (South, North, East or West facing) and inclination (between PV module and horizontal direction) is investigated on performance of modules. In the second stage of research, the whole PV systems in the case study are simulated in EnergyPlus energy simulation software with several PV performance models including Simple, Equivalent one-diode and Sandia. The predicted results by different models are compared with measured data and the validated model is used to provide simulation-based energy yield predictions for wide ranges of scenarios. It has been concluded that orientation of low-slope rooftop PV has negligible impact on annual energy yield but in case of PV external sunshade, east façade and panel slope of 30–40° are the most suitable location and inclination. - Highlights: • Characteristics of PV systems in tropics are analyzed in depth. • The ambiguity toward amorphous panel energy yield in tropics is discussed. • Equivalent-one diode and Sandia models can fairly predict the energy yield. • A general guideline is provided to estimate the energy yield of PV systems in tropics

  14. Assessment of Air-Pollution Control Policy’s Impact on China’s PV Power: A System Dynamics Analysis

    OpenAIRE

    Xiaodan Guo; Dongxiao Niu; Bowen Xiao

    2016-01-01

    Recently, China has brought out several air-pollution control policies, which indicate the prominent position that PV power hold in improving atmosphere environment. Under this policy environment, the development of China’s PV power will be greatly affected. Firstly, after analyzing the influencing path of air-pollution control policies on PV power, this paper built a system dynamics model, which can be used as a platform for predicting China’s PV power development in every policy scenario du...

  15. A Control Strategy for Photovoltaic-Solid Polymer Electrolysis System Based on Surface Temperature of PV Panel

    OpenAIRE

    Riza Muhida; Wahyudi; Rifki Muhida; Ahmad U. Priantoro

    2008-01-01

    Processes to produce hydrogen from solar photovoltaic powered water electrolysis using solid polymer electrolysis are reported. An alternative control of maximum power point tracking method based on analysis of PV panels surface Temperature for the PV-SPE system was designed and implemented. From this analysis an optimal voltage of PV can be obtained and was realized as a reference voltage of Dc-DC converter. By maintenance the output voltage of PV using the reference voltage control, the out...

  16. A Decentralized Wireless Solution to Monitor and Diagnose PV Solar Module Performance Based on Symmetrized-Shifted Gompertz Functions

    OpenAIRE

    Angel Molina-García; José Carlos Campelo; Sara Blanc; Juan José Serrano; Tania García-Sánchez; Bueso, María C.

    2015-01-01

    This paper proposes and assesses an integrated solution to monitor and diagnose photovoltaic (PV) solar modules based on a decentralized wireless sensor acquisition system. Both DC electrical variables and environmental data are collected at PV module level using low-cost and high-energy efficiency node sensors. Data is real-time processed locally and compared with expected PV module performances obtained by a PV module model based on symmetrized-shifted Gompertz functions (as previously deve...

  17. Are we there yet? Improving solar PV economics and power planning in developing countries: The case of Kenya

    OpenAIRE

    Janosch Ondraczek

    2013-01-01

    Despite the rapid decline in the cost of solar photovoltaic (PV) systems in the past five years, even recent academic research suggests that the cost of generating PV electricity remains too high for PV to make a meaningful contribution to the generation of grid electricity in developing countries. This assessment is reflected in the views of policymakers throughout Africa, who often consider PV as a technology suited only to remote locations and small-scale applications. This paper therefore...

  18. Application ofBoost Inverter to Multi Input PV system

    Directory of Open Access Journals (Sweden)

    G.SHINYVIKRAM

    2014-11-01

    Full Text Available With the shortage of the energy and ever increasing of the oil price, research on the renewable and green energy sources, especially the solar arrays and the fuel cells, becomes more and more important. How to achieve high step- up and high efficiency DC/DC converters is the major consideration in the renewable power applications due to the low voltage of PV arrays and fuel cells. The conventional boost converters increase the harmonics rate and add an extra stage of power conversion. This paper proposes a boost dc-ac inverter that can invert and boost the output voltage in a single stage. In this paper the proposed boost dc-ac inverter is applied to the solar power panels and is simulated using Simulink. The output results of the boost inverter are worthy promising.

  19. Fundamentals of PV Efficiency: Limits for Light Absorption

    CERN Document Server

    Khan, M Ryyan; Alam, Muhammad A

    2012-01-01

    A simple thermodynamic argument related to a (weakly absorbing) finite dielectric slab illuminated by sunlight- originally suggested by Yablonovich- leads to the conclusion that the absorption in a dielectric can at best be increased by a factor 4n2. Therefore, the absorption in these materials is always imperfect; the Shockley-Queisser limit can be achieved only asymptotically. In this paper, we make the connection between the degradation in efficiency and the Yablonovich limit explicit and re-derive the 4n2 limit by intuitive geometrical arguments based on Snell's law and elementary rules of probability. Remarkably, the re-derivation suggests strategies of breaking the traditional limit and improving PV efficiency by enhanced light absorption.

  20. Copper Antimony Chalcogenide Thin Film PV Device Development

    Energy Technology Data Exchange (ETDEWEB)

    Welch, Adam W.; Baranowski, Lauryn L.; de Souza Lucas, Francisco Willian; Toberer, Eric S.; Wolden, Colin A.; Zakutayev, Andriy

    2015-06-14

    Emerging ternary chalcogenide thin film solar cell technologies, such as CuSbS2 and CuSbSe2, have recently attracted attention as simpler alternatives to quaternary Cu2ZnSnS4 (CZTS). Despite suitable photovoltaic properties, the initial energy conversion efficiency of CuSbS2 is rather low (0.3%). Here, we report on our progress towards improving the efficiency of CuSbS2 solar cells using a high throughput approach. The combinatorial methodology quickly results in baseline solar cell prototypes with 0.6% efficiency, and then modification of the back contact architecture leads to 1% PV devices. We then translate the optimal CuSbS2 synthesis parameters to CuSbSe2 devices, which show 3% efficiencies.