WorldWideScience

Sample records for automatic preparative gas-liquid

  1. Automatic discrimination of bubbles and slugs in two-phase gas-liquid flow and measurement of the respective velocities

    International Nuclear Information System (INIS)

    Fitremann, J.M.; Guilpin, C.; Postaire, J.

    1976-01-01

    The measurement of the interface velocity in a two-phase gas-liquid flow is a difficult problem, owing to the dispersion of the velocity components of individual bubbles, gas-slugs, droplets, waves, etc. An entirely automatic method is presented, it gives the velocity of slugs and bubbles independently, by discrimination of local phase probe signals into a 'slug' signal and a 'bubble' signal feeding a shape-recognition program. Both discriminated void fractions are also calculated by the apparatus [fr

  2. Automatic cryogenic liquid level controller is safe for use near combustible substances

    Science.gov (United States)

    Krejsa, M.

    1966-01-01

    Automatic mechanical liquid level controller that is independent of any external power sources is used with safety in the presence of combustibles. A gas filled capillary tube which leads from a pressurized chamber, is inserted into the cryogenic liquid reservoir and becomes a liquid level sensing element or probe.

  3. Economics of gas to liquids manufacture

    International Nuclear Information System (INIS)

    Gradassi, M.J.

    1998-01-01

    The last year has seen a great deal in the literature about the rebirth of gas to liquids processes, most notably, Fischer Tropsch processes. This renewed interest has been brought about by a technology that is said to have been so improved that it is now a commercially attractive option for natural gas monetization. No one single reason can be cited for this positive economic change. Rather, it is the result of several technological improvements that together have cut the capital cost of Fischer-Tropsch gas to liquids projects in half. Among these technological improvements are lower cost syngas preparation and lower cost gas to liquids reactors. This paper examines the economics of Fischer-Tropsch gas to liquids manufacture, using recent literature articles to develop process capital costs, operating expenses, liquid product value parameters, and other economic factors, to paint a general picture of the technology's current economic status. While manufacturing economics are reviewed, the answer to the question of gas to liquids project profitability is left to the individual investor whose economic thresholds must, in the final analysis, be met. 15 refs

  4. Continuous gas/liquid–liquid/liquid flow synthesis of 4-fluoropyrazole derivatives by selective direct fluorination

    Directory of Open Access Journals (Sweden)

    Jessica R. Breen

    2011-08-01

    Full Text Available 4-Fluoropyrazole systems may be prepared by a single, sequential telescoped two-step continuous gas/liquid–liquid/liquid flow process from diketone, fluorine gas and hydrazine starting materials.

  5. Automatic isotope gas analysis of tritium labelled organic materials Pt. 1

    International Nuclear Information System (INIS)

    Gacs, I.; Mlinko, S.

    1978-01-01

    A new automatic procedure developed to convert tritium in HTO hydrogen for subsequent on-line gas counting is described. The water containing tritium is introduced into a column prepared from molecular sieve-5A and heated to 550 deg C. The tritium is transferred by isotopic exchange into hydrogen flowing through the column. The radioactive gas is led into an internal detector for radioactivity measurement. The procedure is free of memory effects, provides quantitative recovery with analytical reproducibility better than 0.5% rel. at a preset number of counts. The experimental and analytical results indicate that isotopic exchange between HTO and hydrogen over a column prepared from alumina or molecular sieve-5A can be successfully applied for the quantitative transfer of tritium from HTO into hydrogen for on-line gas countinq. This provides an analytical procedure for the automatic determination of tritium in water with an analytical reproducibility better than 0.5% rel. The exchange process will also be suitable for rapid tritium transfer from water formed during the decomposition of tritium-labelled organic compounds or biological materials. The application of the procedure in automatic isotope gas analysis of organic materials labelled with tritium will be described in subsequent papers (Parts II and III). (T.G.)

  6. US crude oil, natural gas, and natural gas liquids reserves: 1990 annual report

    International Nuclear Information System (INIS)

    1991-09-01

    The primary focus of this report is to provide an accurate estimate of US proved reserves of crude oil, natural gas, and natural gas liquids. These estimates were considered essential to the development, implementation, and evaluation of natural energy policy and legislation. In the past, the government and the public relied upon industry estimates of proved reserves. These estimates were prepared jointly by the American Petroleum Institute (API) and the American Gas Association (AGA) and published in their annual report, Reserves of Crude Oil, Natural Gas Liquids, and Natural Gas in the United States and Canada. However, API and AGA ceased publication of reserves estimates after their 1979 report. By the mid-1970's, various federal agencies had separately established programs to collect data on, verify, or independently estimate domestic proved reserves of crude oil or natural gas. Each program was narrowly defined to meet the particular needs of the sponsoring agency. In response to recognized need for unified, comprehensive proved reserves estimates, Congress in 1977 required the Department of Energy to prepare such estimates. To meet this requirement, the EIA's reserves program was undertaken to establish a unified, verifiable, comprehensive, and continuing statistical series for proved reserves of crude oil and natural gas. The program was expanded to include proved reserves of natural gas liquids in the 1979 report. 36 refs., 11 figs., 16 tabs

  7. Alternating sample changer and an automatic sample changer for liquid scintillation counting of alpha-emitting materials

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1977-08-01

    Two sample changers are described that were designed for liquid scintillation counting of alpha-emitting samples prepared using solvent-extraction chemistry. One operates manually but changes samples without exposing the photomultiplier tube to light, allowing the high voltage to remain on for improved stability. The other is capable of automatically counting up to 39 samples. An electronic control for the automatic sample changer is also described

  8. Automatic liquid nitrogen feeding device

    International Nuclear Information System (INIS)

    Gillardeau, J.; Bona, F.; Dejachy, G.

    1963-01-01

    An automatic liquid nitrogen feeding device has been developed (and used) in the framework of corrosion tests realized with constantly renewed uranium hexafluoride. The issue was to feed liquid nitrogen to a large capacity metallic trap in order to condensate uranium hexafluoride at the exit of the corrosion chambers. After having studied various available devices, a feeding device has been specifically designed to be robust, secure and autonomous, as well as ensuring a high liquid nitrogen flowrate and a highly elevated feeding frequency. The device, made of standard material, has been used during 4000 hours without any problem [fr

  9. Hg⁰ removal from flue gas by ionic liquid/H₂O₂.

    Science.gov (United States)

    Cheng, Guangwen; Bai, Bofeng; Zhang, Qiang; Cai, Ming

    2014-09-15

    1-Alkyl-3-methylimidazolium chloride ionic liquids ([Cnmim] Cl, n=4, 6, 8) were prepared. The ionic liquid was then mixed with hydrogen peroxide (H2O2) to form an absorbent. The Hg(0) removal performance of the absorbent was investigated in a gas/liquid scrubber using simulated flue gas. It was found that the ionic liquid/H2O2 mixture was an excellent absorbent and could be used to remove Hg(0) from flue gas. When the mass ratio of H2O2 to ionic liquid was 0.5, the absorbent showed high Hg(0) removal efficiency (up to 98%). The Hg(0) removal efficiency usually increased with the absorption temperature, while decreased with the increase of alkyl chain length in ionic liquid molecule. The Hg(0) removal mechanism involved with Hg(0) oxidation by H2O2 and Hg(2+) transfer from aqueous phase to ionic liquid phase. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. An automatic tooth preparation technique: A preliminary study

    Science.gov (United States)

    Yuan, Fusong; Wang, Yong; Zhang, Yaopeng; Sun, Yuchun; Wang, Dangxiao; Lyu, Peijun

    2016-04-01

    The aim of this study is to validate the feasibility and accuracy of a new automatic tooth preparation technique in dental healthcare. An automatic tooth preparation robotic device with three-dimensional motion planning software was developed, which controlled an ultra-short pulse laser (USPL) beam (wavelength 1,064 nm, pulse width 15 ps, output power 30 W, and repeat frequency rate 100 kHz) to complete the tooth preparation process. A total of 15 freshly extracted human intact first molars were collected and fixed into a phantom head, and the target preparation shapes of these molars were designed using customised computer-aided design (CAD) software. The accuracy of tooth preparation was evaluated using the Geomagic Studio and Imageware software, and the preparing time of each tooth was recorded. Compared with the target preparation shape, the average shape error of the 15 prepared molars was 0.05-0.17 mm, the preparation depth error of the occlusal surface was approximately 0.097 mm, and the error of the convergence angle was approximately 1.0°. The average preparation time was 17 minutes. These results validated the accuracy and feasibility of the automatic tooth preparation technique.

  11. Nonuniform distribution of gas-liquid system in gas-distributing collector

    Energy Technology Data Exchange (ETDEWEB)

    Kasimov, R.Sh.; Abdullayev, E.A.; Eyubov, A.A.; Khudobakhshiyev, M.R.

    1979-01-01

    In the example of studying GS-1 of the field Shatlyk, the effect of nonuniform distribution of the liquid phase is examined (hydrocarbon condensate, water) on production lines of the unit of low temperature separation on the process of field preparation of gas. In particular, the unequal efficiency of single-type equipment operating under comparable conditions is noted: differences in the magnitude of under recuperation of coal of the recuperation heat exchangers, in the values of the integrated effect of Joule-Thomson, the coefficients of removal of low-temperature separators, etc. A consequence of this situation is deterioration in the quality of gas fed to the main pipe line. It is suggested that efforts be concentrated on developing technical designs which guarantee uniform supply of liquid from the field collector to the production lines of the unit for low temperature separation.

  12. Analysis of gas-liquid metal two-phase flows using a reactor safety analysis code SIMMER-III

    International Nuclear Information System (INIS)

    Suzuki, Tohru; Tobita, Yoshiharu; Kondo, Satoru; Saito, Yasushi; Mishima, Kaichiro

    2003-01-01

    SIMMER-III, a safety analysis code for liquid-metal fast reactors (LMFRs), includes a momentum exchange model based on conventional correlations for ordinary gas-liquid flows, such as an air-water system. From the viewpoint of safety evaluation of core disruptive accidents (CDAs) in LMFRs, we need to confirm that the code can predict the two-phase flow behaviors with high liquid-to-gas density ratios formed during a CDA. In the present study, the momentum exchange model of SIMMER-III was assessed and improved using experimental data of two-phase flows containing liquid metal, on which fundamental information, such as bubble shapes, void fractions and velocity fields, has been lacking. It was found that the original SIMMER-III can suitably represent high liquid-to-gas density ratio flows including ellipsoidal bubbles as seen in lower gas fluxes. In addition, the employment of Kataoka-Ishii's correlation has improved the accuracy of SIMMER-III for gas-liquid metal flows with cap-shape bubbles as identified in higher gas fluxes. Moreover, a new procedure, in which an appropriate drag coefficient can be automatically selected according to bubble shape, was developed. Through this work, the reliability and the precision of SIMMER-III have been much raised with regard to bubbly flows for various liquid-to-gas density ratios

  13. Gas-liquid interface of room-temperature ionic liquids.

    Science.gov (United States)

    Santos, Cherry S; Baldelli, Steven

    2010-06-01

    The organization of ions at the interface of ionic liquids and the vacuum is an ideal system to test new ideas and concepts on the interfacial chemistry of electrolyte systems in the limit of no solvent medium. Whilst electrolyte systems have numerous theoretical and experimental methods used to investigate their properties, the ionic liquids are relatively new and our understanding of the interfacial properties is just beginning to be explored. In this critical review, the gas-liquid interface is reviewed, as this interface does not depend on the preparation of another medium and thus produces a natural interface. The interface has been investigated by sum frequency generation vibrational spectroscopy and ultra-high vacuum techniques. The results provide a detailed molecular-level view of the surface composition and structure. These have been complemented by theoretical studies. The combinations of treatments on this interface are starting to provide a somewhat convergent description of how the ions are organized at this neat interface (108 references).

  14. Preparation of hollow fiber membranes for gas separation

    NARCIS (Netherlands)

    Li, Shu-Guang

    1994-01-01

    Today, immersion precipitation is the most often used process for the preparation of gas separation membranes from polymeric materials. In this process a polymer solution in the form of a thin liquid film or hollow fiber is immersed in a nonsolvent bath where the polymer precipitates and forms a

  15. Water-saving liquid-gas conditioning system

    Science.gov (United States)

    Martin, Christopher; Zhuang, Ye

    2014-01-14

    A method for treating a process gas with a liquid comprises contacting a process gas with a hygroscopic working fluid in order to remove a constituent from the process gas. A system for treating a process gas with a liquid comprises a hygroscopic working fluid comprising a component adapted to absorb or react with a constituent of a process gas, and a liquid-gas contactor for contacting the working fluid and the process gas, wherein the constituent is removed from the process gas within the liquid-gas contactor.

  16. Advances in gas-liquid flows 1990

    International Nuclear Information System (INIS)

    Kim, J.M.; Hashemi, A.

    1990-01-01

    Gas-liquid two-phase flows commonly occur in nature and industrial applications. Rain, clouds, geysers, and waterfalls are examples of natural gas-liquid flow phenomena, whereas industrial applications can be found in nuclear reactors, steam generators, boilers, condensers, evaporators, fuel atomization, heat pipes, electronic equipment cooling, petroleum engineering, chemical process engineering, and many others. The household-variety phenomena such as garden sprinklers, shower, whirlpool bath, dripping faucet, boiling tea pot, and bubbling beer provide daily experience of gas-liquid flows. The papers presented in this volume reflect the variety and richness of gas-liquid two-phase flow and the increasing role it plays in modern technology. This volume contains papers dealing with some recent development in gas-liquid flow science and technology, covering basic gas-liquid flows, measurements and instrumentation, cavitation and flashing flows, countercurrent flow and flooding, flow in various components and geometries liquid metals and thermocapillary effects, heat transfer, nonlinear phenomena, instability, and other special and general topics related to gas-liquid flows

  17. Automatically Preparing Safe SQL Queries

    Science.gov (United States)

    Bisht, Prithvi; Sistla, A. Prasad; Venkatakrishnan, V. N.

    We present the first sound program source transformation approach for automatically transforming the code of a legacy web application to employ PREPARE statements in place of unsafe SQL queries. Our approach therefore opens the way for eradicating the SQL injection threat vector from legacy web applications.

  18. Robot system for preparing lymphocyte chromosome

    International Nuclear Information System (INIS)

    Hayata, Isamu; Furukawa, Akira; Yamamoto, Mikio; Sato, Koki; Tabuchi, Hiroyoshi; Okabe, Nobuo.

    1992-01-01

    Towards the automatization of the scoring of chromosome aberrations in radiation dosimetry with the emphasis on the improvement of biological preparations, the conventional culture and harvesting method was modified. Based on this modified method, a culture and harvest robotic system (CHROSY) for preparing lymphocyte chromosome was developed. The targeted points of the modification are as in the preparing lymphocyte chromosome was developed. The targeted points of the modification are as in the following. 1) Starting culture with purified lymphocytes in a fixed cell number. 2) Avoiding the loss of cells in changing the liquids following centrifugalization. 3) Keeping the quantity of the liquids to be applied to the treatments of cells fixed. 4) Building a system even a beginner can handle. System features are as follows. 1) Operation system: Handling robot having 5 degrees of freedom; a rotator incubator with an automatic sliding door; units for setting and removing pipette tips; a centrifuge equipped with a position adjuster and an automatic sliding door; two aluminium block baths; two nozzles as pipettes and aspirators connected to air pumps; a capping unit with a nozzle for CO 2 gas; a compressor; and an air manipulated syringe. 2) Control system; NEC PC-9801RX21 with CRT; and program written in Basic and Assembly languages on MS-DOS. It took this system 2 hours and 25 minutes to harvest 2 cultures. A fairly good chromosome slide was made from the sample harvested by CHROSY automatically. (author)

  19. The automatic liquid nitrogen filling system for GDA detectors

    Indian Academy of Sciences (India)

    . Abstract. An indigenously developed automatic liquid nitrogen (LN2) filling system has been installed in gamma detector array (GDA) facility at Nuclear Science Centre. Electro-pneumatic valves are used for filling the liquid nitrogen into the ...

  20. US crude oil, natural gas, and natural gas liquids reserves

    International Nuclear Information System (INIS)

    1992-01-01

    This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1991, as well as production volumes for the United States, and selected States and State subdivisions for the year 1991. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), its two major components (nonassociated and associated-dissolved gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, two components of natural gas liquids, lease condensate and natural gas plant liquids, have their reserves and production data presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1991 is also presented

  1. Gas Enrichment at Liquid-Wall Interfaces

    NARCIS (Netherlands)

    Dammer, S.M.; Lohse, Detlef

    2006-01-01

    Molecular dynamics simulations of Lennard-Jones systems are performed to study the effects of dissolved gas on liquid-wall and liquid-gas interfaces. Gas enrichment at walls, which for hydrophobic walls can exceed more than 2 orders of magnitude when compared to the gas density in the bulk liquid,

  2. BORILAIN. Mobile device for automatic continuous supply of liquid injection system backup of a nuclear plant in emergency

    International Nuclear Information System (INIS)

    Lacalle, J.; Traino, J.; Troeung, J.; Arnaldos, A.; Alcaraz, D. A.; Lopez, B.; Ponce, A. T.

    2014-01-01

    This paper presents the design and development of the first automatic mobile device for the preparation of a neutron absorbing solution, and providing continuous, 30 days, of the injection system liquid reserve of a nuclear emergency. The work has been developed by GD Energy Services (GDES) for Electricite de France (EDF). (Author)

  3. Aerospace gas/liquid separator for terrestrial applications

    International Nuclear Information System (INIS)

    Mondt, J.F.

    1996-01-01

    The space gas/liquid separator, a key component in the heat transport subsystem of a space reactor power system, was developed to remove helium gas from liquid lithium in zero gravity. Helium is generated from lithium irradiation in the reactor core and would reach saturation in lithium after 48 hours of full power operations. The gas/liquid separator is also applicable for large commercial powerplants to deaerate the water before and after the feedwater heaters. Another terrestrial application is for industrial companies to use the gas/liquid separator and wet chemistry to remove all the gases from the air and only discharge clean air to the atmosphere. An additional application that resulted from this gas/liquid separator technology, was separating liquid carbon dioxide from nitrogen. This application is opposite from the space application in that it is removing a liquid from a gas rather than a gas from a liquid

  4. Dual liquid and gas chromatograph system

    Science.gov (United States)

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  5. Fundamental research of two-phase flows with high liquid/gas density ratios

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Hibiki, Takashi; Saito, Yasushi; Tobita, Yoshiharu; Konishi, Kensuke; Suzuki, Tohru

    2000-07-01

    In order to analyze the boiling of a fuel-steel mixture pool formed during the core disruptive accident in a fast breeder reactor, it is important to understand the flow characteristics of gas-liquid two-phase pools containing molten reactor materials. Since the liquid/gas density ratio is high, the characteristics of such two-phase flows may differ from those of ordinary flows such as water/air flow. In this study, as a fundamental research of two-phase flows with a high liquid/gas density ratio, the experiments were performed to visualize and measure molten metal (lead-bismuth)/nitrogen gas two-phase flows using a neutron radiography technique. From these experiments, fundamental data such as bubble shapes, void fractions and liquid velocity fields were obtained. In addition, the momentum exchange model of SIMMER-III, which has been developed by JNC, was assessed and improved using the experimental data. In the visualization by neutron radiography, it was found that deformed ellipsoidal bubbles could be seen with smaller gas flux or lower void fractions, and spherical cap bubbles could be seen with larger gas flux or higher void fractions. In addition, a correlation applicable to SIMMER-III was proposed through a comparison between the experimental data and traditional empirical correlations. Furthermore, a visualization experiment using gold-cadmium tracer particles showed that the image processing technique used in the quantification of void fractions is applicable to the measurement of the liquid velocity fields. On the other hand, in the analysis by SIMMER-III, it was confirmed that the original momentum exchange model was appropriate for ellipsoidal bobby flows and that the accuracy of SIMMER-III for cap bubbly flows was much improved with the proposed correlation. Moreover, a new procedure, in which the appropriate drag coefficient could be automatically selected according to bubble shape, was developed. The SIMMER-III code improved through this study can

  6. The Experimental Study of Dynamics of Scaled Gas-Filled Bubble Collapse in Liquid

    Science.gov (United States)

    Pavlenko, Alexander

    2011-06-01

    The article provides results of analyzing special features of the single-bubble sonoluminescence, developing the special apparatus to investigate this phenomenon on a larger-scale basis. Certain very important effects of high energy density physics, i.e. liquid compressibility, shock-wave formation under the collapse of the gas cavity in liquid, shock-wave focusing in the gas-filled cavity, occurrence of hot dense plasma in the focusing area, and high-temperature radiation yield are observed in this phenomenon. Specificity of the process is conditioned by the ``ideal'' preparation and sphericity of the gas-and-liquid contact boundary what makes the collapse process efficient due to the reduced influence of hydrodynamic instabilities. Results of experimental investigations; results of developing the facilities, description of methods used to register parameters of facilities and the system under consideration; analytical estimates how gas-filled bubbles evolve in liquid with the regard for scale effects; results of preliminary 1-D gas dynamic calculations of the gas bubble evolution are presented. The work supported by ISTC Project #2116.

  7. Automatic gas-levitation system for vacuum deposition of laser-fusion targets

    International Nuclear Information System (INIS)

    Jordan, C.W.; Cameron, G.R.; Krenik, R.M.; Crane, J.K.

    1981-01-01

    An improved simple system has been developed to gas-levitate microspheres during vacuum-deposition processes. The automatic operation relies on two effects: a lateral stabilizing force provided by a centering-ring; and an automatically incremented gas metering system to offset weight increases during coating

  8. Thermocapillary and shear driven flows in gas/liquid system in annular duct

    International Nuclear Information System (INIS)

    Gaponenko, Yu; Shevtsova, V; Nepomnyashchy, A

    2011-01-01

    We report the results of numerical study of two-phase flows in annulus for different aspect ratios obtained in the frame of the JEREMI experiment preparation. The geometry of the physical problem is a cylindrical and non-deformable liquid bridge concentrically surrounded by an annular gas channel under conditions of zero gravity. Thermocapillary (Marangoni) convection in liquid bridge of Pr = 68 is analyzed in the case when the interface is subjected to an axial gas stream. The gas flow is counter-directed with respect to the Marangoni flow. The inlet gas velocity U 0 g , temperature difference ΔT between end rods of the liquid bridge and aspect ratio are the control parameters of the system. In the case when the gas stream comes from the cold side, it cools down the interface to a temperature lower than that of the liquid beneath, and in a certain region of the parameter space that cooling causes instability due to a temperature difference in the direction, perpendicular to the interface. The present study is focused on the influence of the aspect ratio on the existence and characteristic features of the oscillatory regime.

  9. Static gas-liquid interfacial direct current discharge plasmas using ionic liquid cathode

    International Nuclear Information System (INIS)

    Kaneko, T.; Baba, K.; Hatakeyama, R.

    2009-01-01

    Due to the unique properties of ionic liquids such as their extremely low vapor pressure and high heat capacity, we have succeeded in creating the static and stable gas (plasmas)-liquid (ionic liquids) interfacial field using a direct current discharge under a low gas pressure condition. It is clarified that the ionic liquid works as a nonmetal liquid electrode, and furthermore, a secondary electron emission coefficient of the ionic liquid is larger than that of conventional metal electrodes. The plasma potential structure of the gas-liquid interfacial region, and resultant interactions between the plasma and the ionic liquid are revealed by changing a polarity of the electrode in the ionic liquid. By utilizing the ionic liquid as a cathode electrode, the positive ions in the plasma region are found to be irradiated to the ionic liquid. This ion irradiation causes physical and chemical reactions at the gas-liquid interfacial region without the vaporization of the ionic liquid.

  10. Effects of gas liquid ratio on the atomization characteristics of gas-liquid swirl coaxial injectors

    Science.gov (United States)

    Kang, Zhongtao; Li, Qinglian; Zhang, Jiaqi; Cheng, Peng

    2018-05-01

    To understand the atomization characteristics and atomization mechanism of the gas-liquid swirl coaxial (GLSC) injector, a back-lighting photography technique has been employed to capture the instantaneous spray images with a high speed camera. The diameter and velocity of the droplets in the spray have been characterized with a Dantec Phase Doppler Anemometry (PDA) system. The effects of gas liquid ratio (GLR) on the spray pattern, Sauter mean diameter (SMD), diameter-velocity distribution and mass flow rate distribution were analyzed and discussed. The results show that the atomization of the GLSC injector is dominated by the film breakup when the GLR is small, and violent gas-liquid interaction when the GLR is large enough. The film breakup dominated spray can be divided into gas acceleration region and film breakup region while the violent gas-liquid interaction dominated spray can be divided into the gas acceleration region, violent gas-liquid interaction region and big droplets breakup region. The atomization characteristics of the GLSC injector is significantly influenced by the GLR. From the point of atomization performance, the increase of GLR has positive effects. It decreases the global Sauter mean diameter (GSMD) and varies the SMD distribution from a hollow cone shape (GLR = 0) to an inverted V shape, and finally slanted N shape. However, from the point of spatial distribution, the increase of GLR has negative effects, because the mass flow rate distribution becomes more nonuniform.

  11. An automatic sodium-loop for testing the lon-term behaviour of sintered bodies flowed through by gas

    International Nuclear Information System (INIS)

    Barkleit, G.; George, G.; Haase, I.; Kiessling, W.

    1980-08-01

    An automatic sodium loop NAKOS for testing the long-term behaviour of porous stainless steel bodies which are flowed through by gas is described. The loop using a special safety protection system is capable of working without control up to 1000 h. During a 500 h-experiment the safety system and the gas permeability measuring method for testing the porous bodies were tested. Both first results of the behaviour of sintered bodies in liquid sodium of high purity and temperatures of about 850 K and some details of the production of these bodies are given. (author)

  12. Detection of radiation-induced hydrocarbons in baked sponged cake prepared with irradiated liquid egg

    Science.gov (United States)

    Schulzki, G.; Spiegelberg, A.; Bögl, K. W.; Schreiber, G. A.

    1995-02-01

    For identification of irradiated food, radiation-induced volatile hydrocarbons (HC) are determined by gas chromatography in the non-polar fraction of fat. However, in complex food matrices the detection is often disturbed by fat-associated compounds. On-line coupling of high performance liquid chromatography (LC) and gas chromatography (GC) is very efficient to remove such compounds from the HC fraction. The high sensitivity of this fast and efficient technique is demonstrated by the example of detection of radiation-induced HC in fat isolated from baked sponge cake which had been prepared with irradiated liquid egg.

  13. Selective gas absorption by ionic liquids

    DEFF Research Database (Denmark)

    Shunmugavel, Saravanamurugan; Kegnæs, Søren; Due-Hansen, Johannes

    2010-01-01

    Reversible absorption performance for the flue gas components CO 2, NO and SO2 has been tested for several different ionic liquids (ILs) at different temperatures and flue gas compositions. Furthermore, different porous, high surface area carriers have been applied as supports for the ionic liquids...... to obtain Supported Ionic Liquid-Phase (SILP) absorber materials. The use of solid SILP absorbers with selected ILs were found to significantly improve the absorption capacity and sorption dynamics at low flue gas concentration, thus making the applicability of ILs viable in technical, continuous flow...... processes for flue gas cleaning. The results show that CO 2, NO and SO2 can be reversible and selective absorbed using different ILs and that Supported Ionic Liquid-Phase (SILP) absorbers are promising materials for industrial flue gas cleaning. Absorption/desorption dynamics can be tuned by temperatures...

  14. Unstable well behaviour in gas well liquid loading

    NARCIS (Netherlands)

    Belfroid, S.P.C.; Wijhe, A. van

    2017-01-01

    Liquid loading is the mechanism that is associated with increased liquid hold-up and liquid back flow at lower gas flow rates in gas production wells. In laboratory, most liquid loading experiments are performed at fixed gas and liquid rates (mass flow controlled). In the field, the well behavior is

  15. Gas-liquid contacting in mixing vessels

    International Nuclear Information System (INIS)

    Mann, R.

    1983-01-01

    This report by Dr. R. Mann of UMIST presents a critical survey of literature on the contacting of gases with liquids in stirred vessels. Research undertaken in the last fifteen years in analysed, and promising areas for future research are identified. The report deals with physical contacting, mass transfer between the gas and liquid phases and the utilisation of the stirred vessel as a gas-liquid reactor. Three sections are given on gas-liquid contacting: physical aspects; interphase mass transfer; and chemical reactions. It also discusses recent new approaches and includes a summary of conclusions, nomenclature and references

  16. Radio-controlled automatic gas meter-reading system; Releve automatique de compteur par radio

    Energy Technology Data Exchange (ETDEWEB)

    Yasui, M. [Osaka Gas Co., Ltd (Japan); Ishikawa, K.; Fujiwara, J. [Tokyo Gas Co., Ltd. (Japan); Ichihashi, T. [Toho Gas Co., Ltd. (Japan)

    2000-07-01

    In Japan, an automatic gas meter-reading system is in operation, also incorporating the functions of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff. This system has been realized by linking microcomputer-controlled gas meters(It's called 'Intelligent gas mater') equipped with automatic shutoff mechanism to the gas utility company operation center via communication lines. While the present system uses cable communication lines, we of Tokyo Gas Co., Ltd., Osaka Gas Co., Ltd. and Toho Gas Co., Ltd., have jointly developed a new system based on radio communication. This paper introduces this new system. While radio-controlled meter-reading systems are used in many countries around the world solely for automatic meter reading, our recently developed system is also capable of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff, thanks to its almost real-time two-way communication function. The new system can serve for a period of ten years without recharging. It is also characterized by its applicability as different systems according to purposes: 1) conventional automatic meter-reading system (terminal network control unit or T-NCU), 2) large-scale radio-controlled meter-reading system, and 3) portable terminal-type radio-controlled meter-reading system. (authors)

  17. Determination of ten pyrethroids in various fruit juices: comparison of dispersive liquid-liquid microextraction sample preparation and QuEChERS method combined with dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Zhang, Yaohai; Zhang, Xuelian; Jiao, Bining

    2014-09-15

    Dispersive liquid-liquid microextraction (DLLME) sample preparation and the quick, easy, cheap, effective, rugged and safe (QuEChERS) method combined with DLLME were developed and compared for the analysis of ten pyrethroids in various fruit juices using gas chromatography-electron capture detection (GC-ECD). QuEChERS-DLLME method has found its widespread applications to all the fruit juices including those samples with more complex matrices (orange, lemon, kiwi and mango) while DLLME was confined to the fruit juices with simpler matrices (apple, pear, grape and peach). The two methods provided acceptable recoveries and repeatability. In addition, the applicabilities of two methods were demonstrated with the real samples and further confirmed by gas chromatography-mass spectrometry (GC-MS). Copyright © 2014. Published by Elsevier Ltd.

  18. Radiometric densimeter for measuring and automatic control of liquid density

    International Nuclear Information System (INIS)

    Wajs, J.

    1982-01-01

    A performance rule of the radiometric densimeter produced by ''POLON ''Works is presented. A simplified analysis of the correction of density indication changes due to liquid temperature variations is described. A method of replacing the measuring pipe carrying the liquid being measured by suitable standards is given. The method is for automatic systems control. (A.S.)

  19. Hydrogen extraction from liquid lithium-lead alloy by gas-liquid contact method

    International Nuclear Information System (INIS)

    Xie Bo; Weng Kuiping; Hou Jianping; Yang Guangling; Zeng Jun

    2013-01-01

    Hydrogen extraction experiment from liquid lithium-lead alloy by gas-liquid contact method has been carried out in own liquid lithium-lead bubbler (LLLB). Experimental results show that, He is more suitable than Ar as carrier gas in the filler tower. The higher temperature the tower is, the greater hydrogen content the tower exports. Influence of carrier gas flow rate on the hydrogen content in the export is jagged, no obvious rule. Although the difference between experimental results and literature data, but it is feasible that hydrogen isotopes extraction experiment from liquid lithium-lead by gas-liquid contact method, and the higher extraction efficiency increases with the growth of the residence time of the alloy in tower. (authors)

  20. Detection of radiation-induced hydrocarbons in baked sponge cake prepared with irradiated liquid egg

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Boegl, K.W.; Schreiber, G.A.

    1995-01-01

    For identification of irradiated food, radiation-induced volatile hydrocarbons (HC) are determined by gas chromatography in the non-polar fraction of fat. However, in complex food matrices the detection is often disturbed by fat-associated compounds. On-line coupling of high performance liquid chromatography (LC) and gas chromatography (GC) is very efficient to remove such compounds from the HC fraction. The high sensitivity of this fast and efficient technique is demonstrated by the example of detection of radiation-induced HC in fat isolated from baked sponge cake which had been prepared with irradiated liquid egg. (Author)

  1. US crude oil, natural gas, and natural gas liquids reserves, 1992 annual report

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-18

    This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1992, as well as production volumes for the United States, and selected States and State subdivisions for the year 1992. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), its two major components (nonassociated and associated-dissolved gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, two components of natural gas liquids, lease condensate and natural gas plant liquids, have their reserves and production data presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1992 is provided.

  2. US crude oil, natural gas, and natural gas liquids reserves, 1992 annual report

    International Nuclear Information System (INIS)

    1993-01-01

    This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1992, as well as production volumes for the United States, and selected States and State subdivisions for the year 1992. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), its two major components (nonassociated and associated-dissolved gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, two components of natural gas liquids, lease condensate and natural gas plant liquids, have their reserves and production data presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1992 is provided

  3. Transport evaluation of a gas-liquid scrubber

    International Nuclear Information System (INIS)

    Brodner, A.J.; Bistline, J.E.; Weber, S.E.

    1982-10-01

    The hydraulics and the mass-transfer behavior of a five-tray, single-bubble-cap, single-downcomer, gas-liquid contactor were studied for use as a gas scrubber. Flooding was not observed at the maximum available liquid and gas flow rates of 0.32 and 464 L/min, respectively. The maximum liquid entrainment was 33% at a gross liquid flow rate of 0.05 L/min. The Murphree-tray efficiencies for absorption of CO 2 (5000 ppM in air) into demineralized water ranged from 0.14 to 0.74 for volumetric liquid-to-gas ratios of 4 x 10 -4 and 2 x 10 -4 , respectively, for k/sub L/a values ranging from 0.088 to 0.36 min -1 . 12 figures, 10 tables

  4. FSU's natural gas liquids business needs investment

    International Nuclear Information System (INIS)

    Plotnikov, V.S.; Berman, M.; Angerinos, G.F.

    1995-01-01

    Production of natural gas liquids has fallen seriously behind its potential in the former Soviet Union (FSU). Restoration of the gas liquids business thus represents a rich investment opportunity. Capital, however, must come from international sources, which remain uncertain about the FSU's legal, commercial, and political systems. If these hurdles can be overcome, FSU output of liquid petroleum gas alone might double between 1990 and 2010. In the FSU, LPG is produced from associated and nonassociated natural gas, condensate, and refinery streams. It also comes from what is known in the FSU as ShFLU--a mixture of propane, butane, pentane, and hexane produced at gas processing plants in Western Siberia and fractionated elsewhere. The paper reviews FSU production of gas liquids focusing on West Siberia, gives a production outlook, and describes LPG use and business development

  5. Gas-to-liquid technologies: India's perspective

    International Nuclear Information System (INIS)

    Reddy Keshav, Tirupati; Basu, S.

    2007-01-01

    Gas-to-liquid (GTL) technologies are capable of converting gas to clean, useful liquid hydrocarbons and thus suitable for addressing problems of remote gas utilization, increase in crude oil price, depletion of fossil fuel and environmental pollution. The Indian state of Tripura is considered to be the richest province with 26 billion cubic meters of gas reserves. Neighboring country Myanmar has huge gas reserves but these reserves remain unutilized mainly because of land-locked situation. GTL is a well developed and proven technology and it is an important option for moving natural gas to the market place. GTL options include not only the well-known production of Fischer-Tropsch synthesis liquids but also the production of oxygen containing fuels, fuel additives and chemicals, such as methanol and DME. An alternative, promising option to convert surplus gas is the direct route of methane conversion, which is more energy efficient than the indirect route since it bypasses the energy intensive endothermic steam reforming step of syngas formation. On-site conversion to liquid products of commercial importance using direct route would make transportation of these natural deposits much more economical and practical. In this paper an attempt has been made to review recent developments in syngas technologies, direct routes of methane conversion into useful liquids, and status of both existing and future developments in GTL industry around the world. Finally challenges in GTL technology are discussed. (author)

  6. Gas/liquid flow configurations

    International Nuclear Information System (INIS)

    Bonin, Jacques; Fitremann, J.-M.

    1978-01-01

    Prediction of flow configurations (morphology) for gas/liquid or liquid/vapour mixtures is an important industrial problem which is not yet fully understood. The ''Flow Configurations'' Seminar of Societe Hydrotechnique de France has framed recommendations for investigation of potential industrial applications for flow configurations [fr

  7. Liquid scintillation counting system with automatic gain correction

    International Nuclear Information System (INIS)

    Frank, R.B.

    1976-01-01

    An automatic liquid scintillation counting apparatus is described including a scintillating medium in the elevator ram of the sample changing apparatus. An appropriate source of radiation, which may be the external source for standardizing samples, produces reference scintillations in the scintillating medium which may be used for correction of the gain of the counting system

  8. Technology and products of gas companies; Gas gaisha no Technology and Products

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-10

    This paper presents the latest technology and products of gas companies. `Newly developed gas table for one-push automatic fish broiling` of Tokyo Gas Co. `Catalytic technology for decomposing dioxin generated by incinerator to make it harmless` of Osaka Gas Co. `Newly developed strong and kindly shower head` of Tokyo Gas Co. By laying fish on a sensor in a grill and appropriately setting upper and lower heating levers, user can skillfully broil fish only by pushing an ignition button. A temperature sensor attached to the center of a grill catches a change in surface temperature of fish, and automatically sets an appropriate broiling time according to the kind and volume of fish. A finish buzzer and automatic extinction mechanism are prepared. The technology decomposes dioxin in exhaust gas of incinerators to make it harmless. The catalyst is prepared by dispersing noble metal or oxide of several angstroms into activated carbon fibers. The shower head can switch hot water power by a control handle

  9. US crude oil, natural gas, and natural gas liquids reserves 1996 annual report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    The EIA annual reserves report series is the only source of comprehensive domestic proved reserves estimates. This publication is used by the Congress, Federal and State agencies, industry, and other interested parties to obtain accurate estimates of the Nation`s proved reserves of crude oil, natural gas, and natural gas liquids. These data are essential to the development, implementation, and evaluation of energy policy and legislation. This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1996, as well as production volumes for the US and selected States and State subdivisions for the year 1996. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), nonassociated gas and associated-dissolved gas (which are the two major types of wet natural gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, reserve estimates for two types of natural gas liquids, lease condensate and natural gas plant liquids, are presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1996 is provided. 21 figs., 16 tabs.

  10. Cavitation and gas-liquid flow in fluid machinery and devices. FED-Volume 190

    International Nuclear Information System (INIS)

    O'Hern, T.J.; Kim, J.H.; Morgan, W.B.; Furuya, O.

    1994-01-01

    Cavitation and gas-liquid two-phase flow have remained important areas in many industrial applications and constantly provided challenges for academic researchers and industrial practitioners alike. Cavitation and two-phase flow commonly occur in fluid machinery such as pumps, propellers, and fluid devices such as orifices, valves, and diffusers. Cavitation not only degrades the performance of these machines and devices but deteriorates the materials. Gas-liquid two-phase flow has also been known to degrade the performance of pumps and propellers and can often induce an instability. The industrial applications of cavitation and two-phase flow can be found in power plants, ship propellers, hydrofoils, and aerospace equipment, to name but a few. The papers presented in this volume reflect the variety and richness of cavitation and gas-liquid two-phase flow in various flow transporting components and the increasing role they play in modern and conventional technologies. Separate abstracts were prepared for 35 papers in this book

  11. U.S. crude oil, natural gas, and natural gas liquids reserves 1997 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Wood, John H.; Grape, Steven G.; Green, Rhonda S.

    1998-12-01

    This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1997, as well as production volumes for the US and selected States and State subdivisions for the year 1997. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), nonassociated gas and associated-dissolved gas (which are the two major types of wet natural gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, reserve estimates for two types of natural gas liquids, lease condensate and natural gas plant liquids, are presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1997 is provided. 21 figs., 16 tabs.

  12. Method for optical 15N analysis of small amounts of nitrogen gas released from an automatic nitrogen analyzer

    International Nuclear Information System (INIS)

    Arima, Yasuhiro

    1981-01-01

    A method of optical 15 N analysis is proposed for application to small amounts of nitrogen gas released from an automatic nitrogen analyzer (model ANA-1300, Carlo Erba, Milano) subjected to certain set modifications. The ANA-1300 was combined with a vacuum line attached by a molecular sieve 13X column. The nitrogen gas released from the ANA-1300 was introduced with a carrier gas of helium into the molecular sieve column which was pre-evacuated at 10 -4 Torr and cooled with outer liquid nitrogen. After removal of the helium by evacuation, the nitrogen gas fixed on the molecular sieve was released by warming the column, and then, it was sealed into pre-evacuated pyrex glass tubes at 4.5 - 5.0 Torr. In the preparation of discharge tubes, contamination of unlabelled nitrogen occurred from the carrier gas of standard grade helium, and the relative lowering of the 15 N value by it was estimated to be less than 1% when over 700 μg nitrogen was charged on the ANA-1300; when 200 μg nitrogen was charged, it was about 3.5%. However, the effect of the contamination could be corrected for by knowing the amount of contaminant nitrogen. In the analysis of plant materials by the proposed method, the coefficient of variation was less than 2%, and no significant difference was observed between results given by the present method and by the ordinary method in which samples were directly pyrolyzed in the discharge tubes by the Dumas method. The present method revealed about 1.5 μg of cross-contaminated nitrogen and was applicable to more than 200 μg of sample nitrogen. (author)

  13. Studies for the requirements of automatic and remotely controlled shutoff valves on hazardous liquids and natural gas pipelines with respect to public and environmental safety

    Energy Technology Data Exchange (ETDEWEB)

    Oland, C. Barry [XCEL Engineering, Inc. (United States); Rose, Simon D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Engineering Science and Technology Div.; Grant, Herb L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Fabrication, Hoisting and Rigging Div.; Lower, Mark D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Fabrication, Hoisting and Rigging Div.; Spann, Mark A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Facility Management Div.; Kirkpatrick, John R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Computational Sciences and Engineering Div.; Sulfredge, C. David [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Computational Sciences and Engineering Div.

    2012-12-01

    This study assesses the effectiveness of block valve closure swiftness in mitigating the consequences of natural gas and hazardous liquid pipeline releases on public and environmental safety. It also evaluates the technical, operational, and economic feasibility and potential cost benefits of installing automatic shutoff valves (ASVs) and remote control valves (RCVs) in newly constructed and fully replaced transmission lines. Risk analyses of hypothetical pipeline release scenarios are used as the basis for assessing: (1) fire damage to buildings and property in Class 1, Class 2, Class 3, and Class 4 high consequence areas (HCAs) caused by natural gas pipeline releases and subsequent ignition of the released natural gas; (2) fire damage to buildings and property in HCAs designated as high population areas and other populated areas caused by hazardous liquid pipeline releases and subsequent ignition of the released propane; and (3) socioeconomic and environmental damage in HCAs caused by hazardous liquid pipeline releases of crude oil. These risk analyses use engineering principles and fire science practices to characterize thermal radiation effects on buildings and humans and to quantify the total damage cost of socioeconomic and environmental impacts. The risk analysis approach used for natural gas pipelines is consistent with risk assessment standards developed by industry and incorporated into Federal pipeline safety regulations. Feasibility evaluations for the hypothetical pipeline release scenarios considered in this study show that installation of ASVs and RCVs in newly constructed and fully replaced natural gas and hazardous liquid pipelines is technically, operationally, and economically feasible with a positive cost benefit. However, these results may not apply to all newly constructed and fully replaced pipelines because site-specific parameters that influence risk analyses and feasibility evaluations often vary significantly from one pipeline segment to

  14. Gas-liquid flow filed in agitated vessels

    International Nuclear Information System (INIS)

    Hormazi, F.; Alaie, M.; Dabir, B.; Ashjaie, M.

    2001-01-01

    Agitated vessels in form of sti reed tank reactors and mixed ferment ors are being used in large numbers of industry. It is more important to develop good, and theoretically sound models for scaling up and design of agitated vessels. In this article, two phase flow (gas-liquid) in a agitated vessel has been investigated numerically. A two-dimensional computational fluid dynamics model, is used to predict the gas-liquid flow. The effects of gas phase, varying gas flow rates and variation of bubbles shape on flow filed of liquid phase are investigated. The numerical results are verified against the experimental data

  15. Simulation Of Gas Focused Liquid Jets

    OpenAIRE

    Zahoor, Rizwan

    2018-01-01

    The main aim of dissertation is to develop an experimentally verified computational fluid dynamic (CFD) model of micron-sized liquid jet, produced by an injection molded Gas Dynamic Virtual Nozzle (GDVN). In these nozzles, liquid jets are efficiently orientedly transporting mass and momentum. They are produced by intelligently projecting hydrodynamic focusing effect from a high-speed stream of a co-flowing lower density and lower viscosity gas on a stream of liquid from a feeding capillary. L...

  16. Experimental study on desulfurization efficiency and gas-liquid mass transfer in a new liquid-screen desulfurization system

    International Nuclear Information System (INIS)

    Sun, Zhongwei; Wang, Shengwei; Zhou, Qulan; Hui, Shi'en

    2010-01-01

    This paper presents a new liquid-screen gas-liquid two-phase flow pattern with discarded carbide slag as the liquid sorbent of sulfur dioxide (SO 2 ) in a wet flue gas desulfurization (WFGD) system. On the basis of experimental data, the correlations of the desulfurization efficiency with flue gas flow rate, slurry flow rate, pH value of slurry and liquid-gas ratio were investigated. A non-dimensional empirical model was developed which correlates the mass transfer coefficient with the liquid Reynolds number, gas Reynolds number and liquid-gas ratio (L/G) based on the available experimental data. The kinetic reaction between the SO 2 and the carbide slag depends on the pressure distribution in this desulfurizing tower, gas liquid flow field, flue gas component, pH value of slurry and liquid-gas ratio mainly. The transient gas-liquid mass transfer involving with chemical reaction was quantified by measuring the inlet and outlet SO 2 concentrations of flue gas as well as the characteristics of the liquid-screen two-phase flow. The mass transfer model provides a necessary quantitative understanding of the hydration kinetics of sulfur dioxide in the liquid-screen flue gas desulfurization system using discarded carbide slag which is essential for the practical application. (author)

  17. Ionic liquid stationary phases for gas chromatography.

    Science.gov (United States)

    Poole, Colin F; Poole, Salwa K

    2011-04-01

    This article provides a summary of the development of ionic liquids as stationary phases for gas chromatography beginning with early work on packed columns that established details of the retention mechanism and established working methods to characterize selectivity differences compared with molecular stationary phases through the modern development of multi-centered cation and cross-linked ionic liquids for high-temperature applications in capillary gas chromatography. Since there are many reviews on ionic liquids dealing with all aspects of their chemical and physical properties, the emphasis in this article is placed on the role of gas chromatography played in the design of ionic liquids of low melting point, high thermal stability, high viscosity, and variable selectivity for separations. Ionic liquids provide unprecedented opportunities for extending the selectivity range and temperature-operating range of columns for gas chromatography, an area of separation science that has otherwise been almost stagnant for over a decade. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Electronic circuit provides automatic level control for liquid nitrogen traps

    Science.gov (United States)

    Turvy, R. R.

    1968-01-01

    Electronic circuit, based on the principle of increased thermistor resistance corresponding to decreases in temperature provides an automatic level control for liquid nitrogen cold traps. The electronically controlled apparatus is practically service-free, requiring only occasional reliability checks.

  19. Cavitation in gas-saturated liquids

    NARCIS (Netherlands)

    Rooze, J.

    2012-01-01

    Oscillating gas bubbles can be created in a liquid by exposing it to ultrasound. These gas bubbles implode if the sound pressure is high enough. This process is called cavitation. Interesting phenomena take place during the collapse. The gas and vapour inside the bubble are compressed and reach

  20. U.S. crude oil, natural gas, and natural gas liquids reserves 1995 annual report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The EIA annual reserves report series is the only source of comprehensive domestic proved reserves estimates. This publication is used by the Congress, Federal and State agencies, industry, and other interested parties to obtain accurate estimates of the Nation`s proved reserves of crude oil, natural gas, and natural gas liquids. These data are essential to the development, implementation, and evaluation of energy policy and legislation. This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1995, as well as production volumes for the US and selected States and State subdivisions for the year 1995. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), nonassociated gas and associated-dissolved gas (which are the two major types of wet natural gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, reserve estimates for two types of natural gas liquids, lease condensate and natural gas plant liquids, are presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1995 is provided. 21 figs., 16 tabs.

  1. Experimental substantiation of combined methods for designing processes for the commercial preparation of gas at gas condensate fields

    Energy Technology Data Exchange (ETDEWEB)

    Gurevich, G R; Karlinskii, E D; Posypkina, T V

    1977-04-01

    An analysis is made of the possibility of using two analytical methods for studying vapor--liquid equilibrium of hydrocarbon mixtures that are used in designing the separation of natural gas and the stabilization of condensate--the Chao and Sider method, which uses computations by equilibrium constants. A combined computational method is proposed for describing a unified process of natural gas separation and condensate stabilization. The method of preparing the original data for the computation of the separation and stabilization processes can be significantly simplified. 10 references, 1 table.

  2. The Development of a Gas-Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus.

    Science.gov (United States)

    Wu, Chuan; Wen, Guojun; Han, Lei; Wu, Xiaoming

    2016-11-18

    The measurement of wellbore annulus gas-liquid two-phase flow in CBM (coalbed methane) wells is of great significance for reasonably developing gas drainage and extraction processes, estimating CBM output, judging the operating conditions of CBM wells and analyzing stratum conditions. Hence, a specially designed sensor is urgently needed for real-time measurement of gas-liquid two-phase flow in CBM wellbore annulus. Existing flow sensors fail to meet the requirements of the operating conditions of CBM wellbore annulus due to such factors as an inapplicable measurement principle, larger size, poor sealability, high installation accuracy, and higher requirements for fluid media. Therefore, based on the principle of a target flowmeter, this paper designs a new two-phase flow sensor that can identify and automatically calibrate different flow patterns of two-phase flows. Upon the successful development of the new flow sensor, lab and field tests were carried out, and the results show that the newly designed sensor, with a measurement accuracy of ±2.5%, can adapt to the operating conditions of CBM wells and is reliable for long-term work.

  3. Liquid oil production from shale gas condensate reservoirs

    Science.gov (United States)

    Sheng, James J.

    2018-04-03

    A process of producing liquid oil from shale gas condensate reservoirs and, more particularly, to increase liquid oil production by huff-n-puff in shale gas condensate reservoirs. The process includes performing a huff-n-puff gas injection mode and flowing the bottom-hole pressure lower than the dew point pressure.

  4. Detection of gas entrainment into liquid metals

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, T., E-mail: t.vogt@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, 01328 Dresden (Germany); Boden, S. [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, 01328 Dresden (Germany); Andruszkiewicz, A. [Faculty of Mechanical and Power Engineering, Wroclaw University of Technology (Poland); Eckert, K. [Technische Universität Dresden, Institute of Fluid Mechanics, 01062 Dresden (Germany); Eckert, S.; Gerbeth, G. [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, 01328 Dresden (Germany)

    2015-12-01

    Highlights: • We present liquid metal experiments dedicated to gas entrainment on the free surface. • Ultrasonic and X-ray attenuation techniques have been used to study the mechanisms of gas entrainment. • A comparison between bubbly flow in water and GaInSn showed substantial differences. • Our results emphasize the importance of liquid metal experiments which are able to provide a suitable data base for numerical code validation. - Abstract: Entrainment of cover gas into the liquid metal coolant is one of the principal safety issues in the design of innovative liquid metal-cooled fast reactors. We present generic experimental studies of this phenomenon in low-melting metals. Ultrasonic and X-ray diagnostic tools were considered for a visualization of gas entrainment at the free surface of the melt. Laboratory experiments were conducted using the eutectic alloy GaInSn, which is liquid at room temperature. Vortex-activated entrainment of air at the free surface of a rotating flow was revealed by ultrasonic techniques. X-ray radioscopy was used to visualize the behavior of argon bubbles inside a slit geometry. The measurements reveal distinct differences between water and GaInSn, especially with respect to the process of bubble formation and the coalescence and breakup of bubbles. Our results emphasize the importance of liquid metal experiments which are able to provide a suitable data base for numerical code validation.

  5. Gas-Liquid Separator design of SWRPRS in PGSFR

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung; Lee, Tae-ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    There is the Sodium-Water Reaction Pressure Relief System (SWRPRS) in PGSFR to prevent the Sodium- Water Reaction (SWR) due to the break of the steam generator tube. The piping to atmosphere includes several components such as gasliquid separator, backpressure rupture disk, and hydrogen igniter. Among these components, gas-liquid separator separates the liquid sodium which is included in gas SWR products not to react sodium and air. In this study, the size of gas-liquid separator, which is based on the hydrogen volume which is exhausted in the sodium dump tank, is determined. To determine the gas-liquid separator for the separation of gas and sodium particle dumped the SDT, Stairmand's model which has high performance among standard cyclone separator models is selected. The body diameter is determined, and other dimensions are determined due to the ratio about the body diameter. Shepherd and Lapple's model is selected as the pressure drop calculation model considering the conservation.

  6. The Effect of Surfactants on Gas-Liquid Pipe Flows

    NARCIS (Netherlands)

    Van Nimwegen, A.T.

    2015-01-01

    Liquid loading is a major problem in the natural gas industry, in which gas production is limited by the accumulation of liquids in the well tubing. Liquid loading can be prevented by the injection of surfactants at the bottom of the well. The surfactants cause the liquid in the well to foam,

  7. Gas holdup in a reciprocating plate bioreactor: Non-Newtonian - liquid phase

    Directory of Open Access Journals (Sweden)

    Naseva Olivera S.

    2002-01-01

    Full Text Available The gas holdup was studied in non-newtonian liquids in a gas-liquid and gas-liquid-solid reciprocating plate bioreactor. Aqueous solutions of carboxy methyl cellulose (CMC; Lucel, Lučane, Yugoslavia of different degrees of polymerization (PP 200 and PP 1000 and concentration (0,5 and 1%, polypropylene spheres (diameter 8.3 mm; fraction of spheres: 3.8 and 6.6% by volume and air were used as the liquid, solid and gas phase. The gas holdup was found to be dependent on the vibration rate, the superficial gas velocity, volume fraction of solid particles and Theological properties of the liquid ohase. Both in the gas-liquid and gas-liquid-solid systems studied, the gas holdup increased with increasing vibration rate and gas flow rate. The gas holdup was higher in three-phase systems than in two-phase ones under otter operating conditions being the same. Generally the gas holdup increased with increasing the volume fraction of solid particles, due to the dispersion action of the solid particles, and decreased with increasing non-Newtonian behaviour (decreasing flow index i.e. with increasing degree of polymerization and solution concentration of CMC applied, as a result of gas bubble coalescence.

  8. The spray characteristic of gas-liquid coaxial swirl injector by experiment

    Directory of Open Access Journals (Sweden)

    Chen Chen

    2017-01-01

    Full Text Available Using the laser phase Doppler particle analyzer (PDPA, the spray characteristics of gas-liquid coaxial swirl injector were studied. The Sauter mean diameter (SMD, axial velocity and size data rate were measured under different gas injecting pressure drop and liquid injecting pressure drop. Comparing to a single liquid injection, SMD with gas presence is obviously improved. So the gas presence has a significant effect on the atomization of the swirl injector. What’s more, the atomization effect of gas-liquid is enhanced with the increasing of the gas pressure drop. Under the constant gas pressure drop, the injector has an optimal liquid pressure drop under which the atomization performance is best.

  9. Innovative Technology for Preparing Washing Liquid During Well Drilling

    Directory of Open Access Journals (Sweden)

    Davydenko A.N.

    2015-09-01

    Full Text Available Technology of washings liquid preparation is worked out. Prospects of the hydrodynamic supercavitation use for preparation of washing liquids during well drilling are substantiated. Theoretical research make it possible to set parameters and work out the construction of cavitational dispergator. The results of theoretical research found their confirmation during practical examinations and became the basis for creation of the technique of washing liquid preparation and construction of cavitational dispergator tested in production conditions.

  10. Natural gas liquids: market outlook

    International Nuclear Information System (INIS)

    Heath, M.

    1996-01-01

    Future market outlook for natural gas liquids was discussed. It was shown that Canadian natural gas and natural gas liquid (NGL) production levels have experienced extraordinary growth over the past few years due to an increased U.S. demand for Canadian natural gas. Recent supply and demand studies have indicated that there will be growing surpluses of NGLs in Canada. By 1996, the majority of NGL surplus that is forecast to be available is ethane (64%), followed by propane (22%), butane (12%) and pentane plus (2%). Throughout the forecast period, the ratio of incremental ethane to the total NGL surplus, over and above forecast demand, was expected to continue to rise. The viability of producing and processing that ethane and transporting it to market, will be crucial. Development of a large ex-Alberta C2+ pipeline from Empress to Mont Belvieu under the reference case supply projection is a possibility, but only if total tariff and fractionation charge on the line is less than or equal to 10 US cents/USG (currently 16-22 US cents/USG). 11 figs

  11. Automatic control of human thermal comfort with a liquid-cooled garment

    Science.gov (United States)

    Kuznetz, L. H.

    1977-01-01

    Water cooling in a liquid-cooled garment is used to maintain the thermal comfort of crewmembers during extravehicular activity. The feasibility of a simple control that will operate automatically to maintain the thermal comfort is established. Data on three test subjects are included to support the conclusion that heat balance can be maintained well within allowable medical limits. The controller concept was also successfully demonstrated for ground-based applications and shows potential for any tasks involving the use of liquid-cooled garments.

  12. Gas/liquid separator for BWR type reactor

    International Nuclear Information System (INIS)

    Soma, Naoshi; Akimoto, Seiichi; Yokoyama, Iwao.

    1993-01-01

    A two phase gas/liquid flow generated at a heating portion of a nuclear reactor is swirled by inlet vanes. The phase gas/liquid flow uprises as a vortex flow in a vortex cylinder, and a liquid phase of a high density gathers at the outer circumference of the vortex cylinder. The liquid phase gathered at the outer circumference is collected at the inlet of a discharge flow channel which protrude into the vortex cylinder and in a three-step structure, and introduced into a recycling liquid phase passing through the discharge flow channel for liquid phase. There is provided a structure that separated liquid collected at the lowermost state in the inlet of the three-step discharge flow channel inlet descends in the discharge flow channel, then uprises in an uprising flow channel and is introduced into the recycling liquid phase by way of a discharge flow channel exit. The height of the discharge flow channel exit is determined equal to that of a liquid level of the recycling liquid phase during rated operation of the reactor. Accordingly, even in a case where the liquid level in the recycling liquid phase is lowered, the liquid level of the uprising flow channel is kept equal to that during rated operation. (I.N.)

  13. X-ray scattering on liquid-gas interfaces; Roentgenstreuung an Fluessigkeits-Gas Grenzflaechen

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Michael

    2006-07-01

    In the framework of this thesis two different theme-fields were studied with dhe methods of the elastic, surface sensitive X-ray scattering. In the first part of the thesis the liquid-gas interfaces water-propane and glycerol-isobutane were studied concerning the structure formation on these interfaces. The system water-propane served for the study of the gas hydrate formation on the water-gas interface. Studies on this interface could give no hints on the formation of propane hydrates or propane-hydrate fragments. However the adsorption of molecularly thin propane films on the water surface was observed. The adsorption behaviour of gases on liquid surfaces was studied by further experiments on the glycerol-isobutane interface. In the second part of the thesis the surfaces of aqueous salt solutions and water were studied. The lateralstructure of these liquid-gas interfaces was studied by the method of the diffuse X-ray scattering.

  14. Microcontroller based automatic liquid poison addition control system

    International Nuclear Information System (INIS)

    Kapatral, R.S.; Ananthakrishnan, T.S.; Pansare, M.G.

    1989-01-01

    Microcontrollers are finding increasing applications in instrumentation where complex digital circuits can be substituted by a compact and simple circuit, thus enhancing the reliability. In addition to this, intelligence and flexibility can be incorporated. For applications not requiring large amount of read/write memory (RAM), microcontrollers are ideally suited since they contain programmable memory (Eprom), parallel input/output lines, data memory, programmable timers and serial interface ports in one chip. This paper describes the design of automatic liquid poison addition control system (ALPAS) using intel's 8 bit microcontroller 8751, which is used to generate complex timing control sequence signals for liquid poison addition to the moderator in a nuclear reactor. ALPAS monitors digital inputs coming from protection system and regulating system of a nuclear reactor and provides control signals for liquid poison addition for long term safe shutdown of the reactor after reactor trip and helps the regulating system to reduce the power of the reactor during operation. Special hardware and software features have been incorporated to improve performance and fault detection. (author)

  15. High-throughput preparation and testing of ion-exchanged zeolites

    International Nuclear Information System (INIS)

    Janssen, K.P.F.; Paul, J.S.; Sels, B.F.; Jacobs, P.A.

    2007-01-01

    A high-throughput research platform was developed for the preparation and subsequent catalytic liquid-phase screening of ion-exchanged zeolites, for instance with regard to their use as heterogeneous catalysts. In this system aqueous solutions and other liquid as well as solid reagents are employed as starting materials and 24 samples are prepared on a library plate with a 4 x 6 layout. Volumetric dispensing of metal precursor solutions, weighing of zeolite and subsequent mixing/washing cycles of the starting materials and distributing reaction mixtures to the library plate are automatically performed by liquid and solid handlers controlled by a single common and easy-to-use programming software interface. The thus prepared materials are automatically contacted with reagent solutions, heated, stirred and sampled continuously using a modified liquid handling. The high-throughput platform is highly promising in enhancing synthesis of catalysts and their screening. In this paper the preparation of lanthanum-exchanged NaY zeolites (LaNaY) on the platform is reported, along with their use as catalyst for the conversion of renewables

  16. Liquid-liquid mixing by gas injection in a pool configuration

    International Nuclear Information System (INIS)

    Corradini, M.L.

    1994-02-01

    An experimental apparatus was designed and constructed to study the mixing process of two immiscible liquids, in a pool configuration, by bottom gas injection. The apparatus consisted of a vertical pyrex conduit of 15.2 centimeters of internal diameter. To the lower part of the conduit was attached a porous plate through which the gas was injected. The experiments were photographically recorded. The pictures were digitized and a method was developed to quantify the mixing region thickness. This method requires knowledge of the void fraction, for each liquid, as a function of the superficial gas velocity. Because of this, void fraction was measured for the bubbly and churn flow regimes, in a pool configuration for every liquid. A new correlation, based on the drift flux model, is proposed for void fraction as a function of superficial gas velocity. It has been observed that mixing can start either in bubbly or churn flow regimes, depending on the liquid pair properties. Three mechanistic models were derived to aid in correlating the data, two for bubbly flow and one for churn flow. A transition region between these two flow regimes, was deduced, but not directly measured. A set of correlations was developed from the models and it is proposed to be implemented in current codes that model Molten Core Concrete Interactions (MCCI). The implications that the present work has on MCCI have been described. It can be deduced that mixing between the oxidic and the metallic phases will occur during the interaction

  17. Gas Marbles: Much Stronger than Liquid Marbles

    Science.gov (United States)

    Timounay, Yousra; Pitois, Olivier; Rouyer, Florence

    2017-06-01

    Enwrapping liquid droplets with hydrophobic particles allows the manufacture of so-called "liquid marbles" [Aussillous and Quéré Nature (London) 411, 924 (2001); , 10.1038/35082026Mahadevan Nature (London)411, 895 (2001), 10.1038/35082164]. The recent intensive research devoted to liquid marbles is justified by their very unusual physical and chemical properties and by their potential for various applications, from microreactors to water storage, including water pollution sensors [Bormashenko Curr. Opin. Colloid Interface Sci. 16, 266 (2011), 10.1016/j.cocis.2010.12.002]. Here we demonstrate that this concept can be successfully applied for encapsulating and protecting small gas pockets within an air environment. Similarly to their liquid counterparts, those new soft-matter objects, that we call "gas marbles," can sustain external forces. We show that gas marbles are surprisingly tenfold stronger than liquid marbles and, more importantly, they can sustain both positive and negative pressure differences. This magnified strength is shown to originate from the strong cohesive nature of the shell. Those interesting properties could be exploited for imprisoning valuable or polluted gases or for designing new aerated materials.

  18. Taylor flow hydrodynamics in gas-liquid-solid micro reactors

    NARCIS (Netherlands)

    Warnier, M.J.F.

    2009-01-01

    Chemical reactions in which a gas phase component reacts with a liquid phase omponent at the surface of a solid catalyst are often encountered in chemical industry. The rate of such a gas-liquid-solid reaction is often limited by the mass transfer rate of the gas phase component, which depends on

  19. Gas-liquid reactor / separator: dynamics and operability characteristics

    NARCIS (Netherlands)

    Ranade, V.; Kuipers, J.A.M.; Versteeg, Geert

    1999-01-01

    A comprehensive mathematical model is developed to simulate gas¿liquid reactor in which both, reactants as well as products enter or leave the reactor in gas phase while the reactions take place in liquid phase. A case of first-order reaction (isothermal) was investigated in detail using the dynamic

  20. Some experimental results for an automatic helium liquefier

    International Nuclear Information System (INIS)

    Watanabe, T.; Kudo, T.; Kuraoka, Y.; Sakura, K.; Tsuruga, H.; Watanabe, T.

    1984-01-01

    This chapter describes the testing of an automatic cooldown system. The liquefying machine examined is a CTi Model 1400. The automatic helium gas liquefying system is operated by using sequence control with a programmable controller. The automatic mode is carried out by operation of two compressors. The monitoring system consists of 41 remote sensors. Liquid level is measured by a superconducting level meter. The J-T valve and return valve, which require precise control, are operated by pulse motors. The advantages of the automatic cooldown system are reduced operator man power; temperatures and pressures are changed smoothly, so that the flow chart of automation is simple; and the system makes continuous liquefier operation possible

  1. Flow chemistry: intelligent processing of gas-liquid transformations using a tube-in-tube reactor.

    Science.gov (United States)

    Brzozowski, Martin; O'Brien, Matthew; Ley, Steven V; Polyzos, Anastasios

    2015-02-17

    CONSPECTUS: The previous decade has witnessed the expeditious uptake of flow chemistry techniques in modern synthesis laboratories, and flow-based chemistry is poised to significantly impact our approach to chemical preparation. The advantages of moving from classical batch synthesis to flow mode, in order to address the limitations of traditional approaches, particularly within the context of organic synthesis are now well established. Flow chemistry methodology has led to measurable improvements in safety and reduced energy consumption and has enabled the expansion of available reaction conditions. Contributions from our own laboratories have focused on the establishment of flow chemistry methods to address challenges associated with the assembly of complex targets through the development of multistep methods employing supported reagents and in-line monitoring of reaction intermediates to ensure the delivery of high quality target compounds. Recently, flow chemistry approaches have addressed the challenges associated with reactions utilizing reactive gases in classical batch synthesis. The small volumes of microreactors ameliorate the hazards of high-pressure gas reactions and enable improved mixing with the liquid phase. Established strategies for gas-liquid reactions in flow have relied on plug-flow (or segmented flow) regimes in which the gas plugs are introduced to a liquid stream and dissolution of gas relies on interfacial contact of the gas bubble with the liquid phase. This approach confers limited control over gas concentration within the liquid phase and is unsuitable for multistep methods requiring heterogeneous catalysis or solid supported reagents. We have identified the use of a gas-permeable fluoropolymer, Teflon AF-2400, as a simple method of achieving efficient gas-liquid contact to afford homogeneous solutions of reactive gases in flow. The membrane permits the transport of a wide range of gases with significant control of the stoichiometry of

  2. Identifying Liquid-Gas System Misconceptions and Addressing Them Using a Laboratory Exercise on Pressure-Temperature Diagrams of a Mixed Gas Involving Liquid-Vapor Equilibrium

    Science.gov (United States)

    Yoshikawa, Masahiro; Koga, Nobuyoshi

    2016-01-01

    This study focuses on students' understandings of a liquid-gas system with liquid-vapor equilibrium in a closed system using a pressure-temperature ("P-T") diagram. By administrating three assessment questions concerning the "P-T" diagrams of liquid-gas systems to students at the beginning of undergraduate general chemistry…

  3. Technological innovations to development remote gas reserves: gas-to-liquids; Inovacoes tecnologicas no desenvolvimento de reservas remotas de gas natural: gas-to-liquids

    Energy Technology Data Exchange (ETDEWEB)

    Maculan, Berenice D. [Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis (ANP), Rio de Janeiro, RJ (Brazil); Falabella, Eduardo [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2004-07-01

    The GTL - gas to liquids technology was born in Germany, after the 20's with the goal to product liquid fuel from coal to supply the bellicose and domestic demand. The grow of the petroleum industry lead the world to the forgiveness of the GTL technology, except in South Africa. In the last two decades the number of news natural gas reserves and the perspectives of the increase demand from natural gas for the next 20 years change this scenario. Nearly 60% of this reserves are calling stranded or remote, meaning reserves which can't produce with conventional technologies (logistics and economics barriers). So, the oil and gas industry restart to analyze the economics and applicability of the GTL technology. The competitively and applicability of this technology were evaluated and compared to the traditional way of natural gas transport, as well as the solidification of the new environmental rules and the creation of niche to this kind of fuel - the cleans ones - seams the cause of this changes in the oil and gas industries. Which began to adjust to all this news rules and conditions, as show in the sum of investments in R and D area. So, is in this new scenario that the reappear of GTL technology is consider has a technological innovation. (author)

  4. Analysis of spatial and temporal spectra of liquid film surface in annular gas-liquid flow

    Science.gov (United States)

    Alekseenko, Sergey; Cherdantsev, Andrey; Heinz, Oksana; Kharlamov, Sergey; Markovich, Dmitriy

    2013-09-01

    Wavy structure of liquid film in annular gas-liquid flow without liquid entrainment consists of fast long-living primary waves and slow short-living secondary waves. In present paper, results of spectral analysis of this wavy structure are presented. Application of high-speed LIF technique allowed us to perform such analysis in both spatial and temporal domains. Power spectra in both domains are characterized by one-humped shape with long exponential tail. Influence of gas velocity, liquid Reynolds number, liquid viscosity and pipe diameter on frequency of the waves is investigated. When gravity effect is much lesser than the shear stress, similarity of power spectra at different gas velocities is observed. Using combination of spectral analysis and identification of characteristic lines of primary waves, frequency of generation of secondary waves by primary waves is measured.

  5. Preparation and use of 195m Au-containing liquid

    International Nuclear Information System (INIS)

    Panek, K.J.

    1983-01-01

    A 195m Au-containing liquid is prepared by adsorbing 195m-Hg on an adsorption agent and then eluting the daughter radioisotope 195m-Au. A radioisotope generator and the adsorption agent to be used in preparation of 195m Au-containing liquids are also claimed

  6. Preparation of 'dead water' for low background liquid scintillation counting

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Niwa, Takeo; Kawai, Hiroshi

    1987-01-01

    'Dead water', low level tritiated water is indispensable to measure tritium concentration in environmental waters using a low background liquid scintillation counter. Water produced by combustion of natural gas, or deep sea water etc. are usually used for the above purpose. A new method of reducing tritium concentration in natural water has been introduced for preparation of 'dead water'. This method is to combine hydrogen-oxygen mixture produced by water electrolysis with hopcalite catalyzer at 700 deg C. Deep well water was electrolized up to 2/3 volume, and tritium concentration of recombined water was reduced to be about one third of that of the original one. (author)

  7. A Simple Approach to Characterize Gas-Aqueous Liquid Two-phase Flow Configuration Based on Discrete Solid-Liquid Contact Electrification.

    Science.gov (United States)

    Choi, Dongwhi; Lee, Donghyeon; Kim, Dong Sung

    2015-10-14

    In this study, we first suggest a simple approach to characterize configuration of gas-aqueous liquid two-phase flow based on discrete solid-liquid contact electrification, which is a newly defined concept as a sequential process of solid-liquid contact and successive detachment of the contact liquid from the solid surface. This approach exhibits several advantages such as simple operation, precise measurement, and cost-effectiveness. By using electric potential that is spontaneously generated by discrete solid-liquid contact electrification, the configurations of the gas-aqueous liquid two-phase flow such as size of a gas slug and flow rate are precisely characterized. According to the experimental and numerical analyses on parameters that affect electric potential, gas slugs have been verified to behave similarly to point electric charges when the measuring point of the electric potential is far enough from the gas slug. In addition, the configuration of the gas-aqueous liquid two-phase microfluidic system with multiple gas slugs is also characterized by using the presented approach. For a proof-of-concept demonstration of using the proposed approach in a self-triggered sensor, a gas slug detector with a counter system is developed to show its practicality and applicability.

  8. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from a...

  9. Removing well bore liquid blockage by gas injection

    International Nuclear Information System (INIS)

    Ahmed, Tarek

    2000-01-01

    Gas condensate reservoirs have long presented production problems when the pressure around the well bore drops below the dew point pressure. The formation of the condensate around the well bore can be thought of as an additional 'skin' that causes a reduction in the gas flow rates. Many processes have been used successfully to prevent or reduce the formation of liquids within the entire reservoir, such as pressure maintenance schemes and gas cycling processes. The pressure maintenance scheme is designed to keep the reservoir pressure at or above the dew point pressure while the gas cycling process is intended to reduce the liquid dropout by vaporization.Often times the pressure in the near-well bore region of the reservoir falls below the dew point pressure, while the pressure in the reservoir remains higher than the dew point pressure. As the near-well bore pressure drops below the dew point pressure, retrograde condensation occurs leading to the formation and then the mobilization of the condensate phase towards the producing wells. The liquid phase accumulates in the near Well bore region, forming a ring, which progressively reduces the gas deliverability. This study is designed to provide an insight into the mechanism of gas injection process in reducing gas-well productivity losses due to condensate blocking in the near well bore region. The study also evaluates the effectiveness of lean gas, N 2 , and CO 2 Huff 'n' Puff injection technique in removing the liquid dropout accumulation in and around the well bore. Results of the study show the importance of selecting the optimum injection volume and pressure. (author)

  10. The effect of the gas-liquid density ratio on the liquid film thickness in vertical upward annular flow

    International Nuclear Information System (INIS)

    Mori, Shoji; Okuyama, Kunito

    2010-01-01

    Annular two phase flow is encountered in many industrial equipments, including flow near nuclear fuel rods in boiling water reactor (BWR). Especially, disturbance waves play important roles in the pressure drop, the generation of entrainments, and the dryout of the liquid film. Therefore, it is important to clarify the behavior of disturbance waves and base film. However, most of the previous studies have been performed under atmospheric pressure conditions that provide the properties of liquid and gas which are significantly different from those of a BWR. Therefore, the effect of properties in gas and liquid on liquid film characteristics should be clarified. In this paper we focus on the effect of gas-liquid density ratio on liquid film thickness characteristics. The experiments have been conducted at four density ratio conditions (ρ L /ρ G =763, 451, 231, and 31). As a result, it was found that liquid film thickness characteristics including the effect of liquid/gas density ratios were well correlated with a gas Weber number and the liquid Reynolds number in the wide range of experimental conditions (ρ L /ρ G : 31-763, We: 10-1800, Re L : 500-2200). (author)

  11. Void fraction fluctuations in two-phase gas-liquid flow

    International Nuclear Information System (INIS)

    Ulbrich, R.

    1987-01-01

    Designs of the apparatus in which two-phase gas-liquid flow occurs are usually based on the mean value of parameters such as pressure drop and void fraction. The flow of two-phase mixtures generally presents a very complicated flow structure, both in terms of the unsteady formation on the interfacial area and in terms of the fluctuations of the velocity, pressure and other variables within the flow. When the gas void fraction is near 0 or 1 / bubble or dispersed flow regimes / then oscillations of void fraction are very small. The intermittent flow such as plug and slug/ froth is characterized by alternately flow portions of liquid and gas. It influences the change of void fractions in time. The results of experimental research of gas void fraction fluctuations in two-phase adiabatic gas-liquid flow in a vertical pipe are presented

  12. Hydrodynamics in a pressurized cocurrent gas-liquid trickle bed reactor

    NARCIS (Netherlands)

    Wammes, Wino J.A.; Westerterp, K.R.

    1991-01-01

    The influence of gas density on total external liquid hold-up, pressure drop and gas-liquid interfacial area, under trickle-flow conditions, and the transition to pulse flow have been investigated with nitrogen or helium as the gas phase up to 7.5 MPa. It is concluded that the hydrodynamics depends

  13. Automatic dispensing of liquid nitrogen in submilliliter doses

    Science.gov (United States)

    Milner, C. J.

    1984-10-01

    Well-controlled doses of 0.2 to 0.5 ml of liquid nitrogen are delivered, on electrical signal (not more than once per 5 s), as fills of a miniature bucket raised by an automatic hoist. The bucket is lifted, brimming, from the storage flask and then moved sideways until over the receiver. At this point, a steel ball, which has been resting in and sealing a drain hole in the bucket, is lifted from its seat by a magnet fixed alongside the (now descending) bucket. Design features are outlined: some alternative designs, valving liquid through a short drain tube fixed in the storage flask, are briefly reviewed. In tests the device delivered 74 g (approx. 260 doses) during 63 min, the loss by evaporation meanwhile being 11 g from the bucket, implying a transfer efficiency of 87%. An indirect measure indicated the dose sizes as 354±10 μl approximately.

  14. The spray characteristic of gas-liquid coaxial swirl injector by experiment

    OpenAIRE

    Chen Chen; Zhihui Yan; Yang Yang; Hongli Gao; Shunhua Yang; Lei Zhang

    2017-01-01

    Using the laser phase Doppler particle analyzer (PDPA), the spray characteristics of gas-liquid coaxial swirl injector were studied. The Sauter mean diameter (SMD), axial velocity and size data rate were measured under different gas injecting pressure drop and liquid injecting pressure drop. Comparing to a single liquid injection, SMD with gas presence is obviously improved. So the gas presence has a significant effect on the atomization of the swirl injector. What’s more, the atomization eff...

  15. Characterizations of gas purge valves for liquid alignment and gas removal in a microfluidic chip

    International Nuclear Information System (INIS)

    Chuang, Han-Sheng; Thakur, Raviraj; Wereley, Steven T

    2012-01-01

    Two polydimethylsiloxane (PDMS) gas purge valves for excessive gas removal in general lab-on-a-chip applications are presented in this paper. Both valves are devised based on a three-layer configuration comprising a top layer for liquid channels, a membrane and a bottom layer for gas channels. The pneumatic valves work as a normal gateway for fluids when the membrane is bulged down (open state) by vacuum or pushed up (closed state) by pressure. In the closed state, the air in front of a liquid can be removed through a small notch or a permeable PDMS membrane by compressing the liquid. The purge valve with a small notch across its valve seat, termed surface-tension (ST) valve, can be operated with pressure under 11.5 kPa. The liquid is mainly retained by the surface tension resulting from the hydrophobic channel walls. In contrast, the purge valve with vacuum-filled grooves adjacent to a liquid channel, termed gas-permeation (GP) valve, can be operated at pressure above 5.5 kPa. Based on the principle of gas permeation, the excessive air can be slowly removed through the vent grooves. Detailed evaluations of both valves in a pneumatically driven microfluidic chip were conducted. Specifically, the purge valves enable users to remove gas and passively align liquids at desired locations without using sensing devices or feedback circuits. Finally, a rapid mixing reaction was successfully performed with the GP valves, showing their practicability as incorporated in a microfluidic chip. (paper)

  16. Regulation and Measurement of the Heat Generated by Automatic Tooth Preparation in a Confined Space.

    Science.gov (United States)

    Yuan, Fusong; Zheng, Jianqiao; Sun, Yuchun; Wang, Yong; Lyu, Peijun

    2017-06-01

    The aim of this study was to assess and regulate heat generation in the dental pulp cavity and circumambient temperature around a tooth during laser ablation with a femtosecond laser in a confined space. The automatic tooth preparing technique is one of the traditional oral clinical technology innovations. In this technique, a robot controlled an ultrashort pulse laser to automatically complete the three-dimensional teeth preparing in a confined space. The temperature control is the main measure for protecting the tooth nerve. Ten tooth specimens were irradiated with a femtosecond laser controlled by a robot in a confined space to generate 10 teeth preparation. During the process, four thermocouple sensors were used to record the pulp cavity and circumambient environment temperatures with or without air cooling. A statistical analysis of the temperatures was performed between the conditions with and without air cooling (p heat generated in the pulp cavity was lower than the threshold for dental pulp damage. These results indicate that femtosecond laser ablation with air cooling might be an appropriate method for automatic tooth preparing.

  17. Stabilized ultrathin liquid membranes for gas separations

    International Nuclear Information System (INIS)

    Deetz, D.W.

    1987-01-01

    Although immobilized liquid membranes have the desirable properties of high selectivity and permeability, their practical application to gas phase separations is hindered because of the instability of the liquid phase and the relative thickness of current membranes. The problem of liquid instability, which is due to both liquid volatilization and flooding, can be reduced, or eliminated, by immobilizing the liquid phase in pores small enough to significantly reduce the molar free energy of the solution via the Kelvin effect. The obstacle of membrane thickness can be overcome by selectively immobilizing the liquid phase into the skin of a porous asymmetric membranes

  18. Ionic liquid-facilitated preparation of lignocellulosic composites

    Science.gov (United States)

    Lignocellulosic composites (LCs) were prepared by partially dissolving cotton along with steam exploded Aspen wood and burlap fabric reinforcements utilizing an ionic liquid (IL) solvent. Two methods of preparation were employed. In the first method, a controlled amount of IL was added to preassembl...

  19. State-of-the-art review of liquid loading in gas wells

    Energy Technology Data Exchange (ETDEWEB)

    Falcone, G. [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany). ITE; Barbosa, J.R. Jr. [Universidade Federal de Santa Catarina, Florianopolis, SC (Brazil). Dept. of Mechanical Engineering

    2013-08-01

    Gas wells suffering from liquid loading are incapable of removing the liquid associated with produced gas from the wellbore. This phenomenon is initiated when the upward gas velocity in the well falls below a critical value at which point the liquid that was initially flowing upwards, begins to fall back. This liquid accumulates downhole, where it increases the hydrostatic back-pressure on the reservoir, destabilises the multiphase flow in the well (following flow regime changes), decreases production rate and, in severe cases, kills the well. The typical liquid loading sequence begins with a gas flow rate that is high enough to transport all liquids to surface and there is no liquid fall-back in the well. However, as the gas velocity slows or the liquid content in the well rises, there is insufficient energy in the well to carry all liquids to surface and some begins to flow backwards. As the hydrostatic head downhole increases, the liquid column that has accumulated in the well can re-enter the near-wellbore region of the reservoir. This results in the well becoming 'unloaded' so that it can flow once more, with the gas carrying all liquids to surface. However, the reinjection of liquids into the reservoir may cause formation damage, which will impair the well productivity. This cycle continues, providing the typical intermittent response of liquid-loaded gas wells, until the reservoir potential starts to fall or the liquid yield rises. Diagnosing liquid loading is often difficult as the affected well(s) may continue production without any substantial performance impairment for a long period of time. Typical symptoms of liquid loading include sharp drops in the cumulative production decline curve, the onset of liquid slugs in the surface facilities, abrupt changes in the flowing pressure gradient, low temperature spikes at the wellhead and declining water production or condensate-gas-ratio. Many remedial lifting options have been developed for use in

  20. A study of stratified gas-liquid pipe flow

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, George W.

    2005-07-01

    This work includes both theoretical modelling and experimental observations which are relevant to the design of gas condensate transport lines. Multicomponent hydrocarbon gas mixtures are transported in pipes over long distances and at various inclinations. Under certain circumstances, the heavier hydrocarbon components and/or water vapour condense to form one or more liquid phases. Near the desired capacity, the liquid condensate and water is efficiently transported in the form of a stratified flow with a droplet field. During operating conditions however, the flow rate may be reduced allowing liquid accumulation which can create serious operational problems due to large amounts of excess liquid being expelled into the receiving facilities during production ramp-up or even in steady production in severe cases. In particular, liquid tends to accumulate in upward inclined sections due to insufficient drag on the liquid from the gas. To optimize the transport of gas condensates, a pipe diameters should be carefully chosen to account for varying flow rates and pressure levels which are determined through the knowledge of the multiphase flow present. It is desirable to have a reliable numerical simulation tool to predict liquid accumulation for various flow rates, pipe diameters and pressure levels which is not presently accounted for by industrial flow codes. A critical feature of the simulation code would include the ability to predict the transition from small liquid accumulation at high flow rates to large liquid accumulation at low flow rates. A semi-intermittent flow regime of roll waves alternating with a partly backward flowing liquid film has been observed experimentally to occur for a range of gas flow rates. Most of the liquid is transported in the roll waves. The roll wave regime is not well understood and requires fundamental modelling and experimental research. The lack of reliable models for this regime leads to inaccurate prediction of the onset of

  1. Characteristics of Gas-liquid Mass Transfer and Interfacial Area in a Bubble Column

    International Nuclear Information System (INIS)

    Lim, Dae Ho; Yoo, Dong Jun; Kang, Yong

    2015-01-01

    Characteristics of gas-liquid mass transfer and interfacial area were investigated in a bubble column of diameter and height of 0.102 m and 2.5 m, respectively. Effects of gas and liquid velocities on the volumetric gas-liquid mass transfer coefficient (k L a), interfacial area (a) and liquid side true mass transfer coefficient (k L ) were examined. The interfacial area and volumetric gas-liquid mass transfer coefficient were determined directly by adopting the simultaneous physical desorption of O 2 and chemical absorption of CO 2 in the column. The values of k L a and a increased with increasing gas velocity but decreased with increasing liquid velocity in the bubble column which was operated in the churn turbulent flow regime. The value of k L increased with increasing gas velocity but did not change considerably with increasing liquid velocity. The liquid side mass transfer was found to be related closely to the liquid circulation as well as the effective contacting frequency between the bubbles and liquid phases

  2. Characteristics of Gas-liquid Mass Transfer and Interfacial Area in a Bubble Column

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Dae Ho; Yoo, Dong Jun; Kang, Yong [Chungnam National University, Daejeon (Korea, Republic of)

    2015-02-15

    Characteristics of gas-liquid mass transfer and interfacial area were investigated in a bubble column of diameter and height of 0.102 m and 2.5 m, respectively. Effects of gas and liquid velocities on the volumetric gas-liquid mass transfer coefficient (k{sub L}a), interfacial area (a) and liquid side true mass transfer coefficient (k{sub L}) were examined. The interfacial area and volumetric gas-liquid mass transfer coefficient were determined directly by adopting the simultaneous physical desorption of O{sub 2} and chemical absorption of CO{sub 2} in the column. The values of k{sub L}a and a increased with increasing gas velocity but decreased with increasing liquid velocity in the bubble column which was operated in the churn turbulent flow regime. The value of k{sub L} increased with increasing gas velocity but did not change considerably with increasing liquid velocity. The liquid side mass transfer was found to be related closely to the liquid circulation as well as the effective contacting frequency between the bubbles and liquid phases.

  3. Liquid dispersion in trickle-bed reactors with gas-liquid cocurrent downflow

    International Nuclear Information System (INIS)

    Chu, C.F.; Ng, K.M.

    1986-01-01

    The flow pattern can deviate from ideal plug flow in both trickling and pulsing flows. The liquid dispersion in those flow regimes are investigated separately, as the mechanisms causing the deviation of flow pattern from plug flow are different. In trickling flow, the dispersion of the liquid phase occurs in the flow path which is determined with computer-generated packed column. Dispersion in pulsing flow is studied with a combination of the method of characteristics and analysis of liquid dispersion in the liquid slug and gas pulse. The axial dispersion coefficients are then determined based on Monte Carlo simulation. Finally, liquid dispersion in trickle beds containing porous packings is also discussed

  4. Automatic Transmission Of Liquid Nitrogen

    Directory of Open Access Journals (Sweden)

    Sumedh Mhatre

    2015-08-01

    Full Text Available Liquid Nitrogen is one of the major substance used as a chiller in industry such as Ice cream factory Milk Diary Storage of blood sample Blood Bank etc. It helps to maintain the required product at a lower temperature for preservation purpose. We cannot fully utilise the LN2 so practically if we are using 3.75 litre LN2 for a single day then around 12 of LN2 450 ml is wasted due to vaporisation. A pressure relief valve is provided to create a pressure difference. If there is no pressure difference between the cylinder carrying LN2 and its surrounding it will results in damage of container as well as wastage of LN2.Transmission of LN2 from TA55 to BA3 is carried manually .So care must be taken for the transmission of LN2 in order to avoid its wastage. With the help of this project concept the transmission of LN2 will be carried automatically so as to reduce the wastage of LN2 in case of manual operation.

  5. Upgradation of automatic liquid scintillation counting system

    International Nuclear Information System (INIS)

    Bhattacharya, Sadhana; Behere, Anita; Sonalkar, S.Y.; Vaidya, P.P.

    2001-01-01

    This paper describes the upgradation of Microprocessor based Automatic Liquid Scintillation Counting systems (MLSC). This system was developed in 1980's and subsequently many systems were manufactured and supplied to Environment Survey labs at various Nuclear Power Plants. Recently this system has been upgraded to a more sophisticated one by using PC add-on hardware and developing Windows based software. The software implements more intuitive graphical user interface and also enhances the features making it comparable with commercially available systems. It implements data processing using full spectrum analysis as against channel ratio method adopted earlier, improving the accuracy of the results. Also it facilitates qualitative as well as quantitative analysis of the β-spectrum. It is possible to analyze a sample containing an unknown β-source. (author)

  6. Gas flow headspace liquid phase microextraction.

    Science.gov (United States)

    Yang, Cui; Qiu, Jinxue; Ren, Chunyan; Piao, Xiangfan; Li, Xifeng; Wu, Xue; Li, Donghao

    2009-11-06

    There is a trend towards the use of enrichment techniques such as microextraction in the analysis of trace chemicals. Based on the theory of ideal gases, theory of gas chromatography and the original headspace liquid phase microextraction (HS-LPME) technique, a simple gas flow headspace liquid phase microextraction (GF-HS-LPME) technique has been developed, where the extracting gas phase volume is increased using a gas flow. The system is an open system, where an inert gas containing the target compounds flows continuously through a special gas outlet channel (D=1.8mm), and the target compounds are trapped on a solvent microdrop (2.4 microL) hanging on the microsyringe tip, as a result, a high enrichment factor is obtained. The parameters affecting the enrichment factor, such as the gas flow rate, the position of the microdrop, the diameter of the gas outlet channel, the temperatures of the extracting solvent and of the sample, and the extraction time, were systematically optimized for four types of polycyclic aromatic hydrocarbons. The results were compared with results obtained from HS-LPME. Under the optimized conditions (where the extraction time and the volume of the extracting sample vial were fixed at 20min and 10mL, respectively), detection limits (S/N=3) were approximately a factor of 4 lower than those for the original HS-LPME technique. The method was validated by comparison of the GF-HS-LPME and HS-LPME techniques using data for PAHs from environmental sediment samples.

  7. Synthesis gas production via hybrid steam reforming of natural gas and bio-liquids

    OpenAIRE

    Balegedde Ramachandran, P.

    2013-01-01

    This thesis deals with (catalytic) steam reforming of bio-liquids for the production of synthesis gas. Glycerol, both crude from the biodiesel manufacturing and refined, and pyrolysis oil are tested as bio-based feedstocks. Liquid bio-based feeds could be preferred over inhomogeneous fibrous solid biomass because of their logistic advantages, better mineral balance, and better processability. Especially the ease of pressurization, which is required for large scale synthesis gas production, is...

  8. Visualization and measurement of liquid velocity field of gas-liquid metal two-phase flow using neutron radiography

    International Nuclear Information System (INIS)

    Saito, Yasushi; Suzuki, Tohru; Matsubayashi, Masahito

    2000-01-01

    In a core melt accident of a fast breeder reactor, a possibility of re-criticality is anticipated in the molten fuel-steel mixture pool. One of the mechanisms to suppress the re-criticality is the boiling of steel in the molten fuel-steel mixture pool because of the negative void reactivity effect. To evaluate the reactivity change due to boiling, it is necessary to know the characteristics of gas-liquid two-phase flow in the molten fuel-steel mixture pool. For this purpose, boiling bubbles in a molten fuel-steel mixture pool were simulated by adiabatic gas bubbles in a liquid metal pool to study the basic characteristics of gas-liquid metal two-phase mixture. Visualization of the two-phase mixture and measurements of liquid phase velocity and void fraction were conducted by using neutron radiography and image processing techniques. From these measurements, the basic characteristics of gas-liquid metal two-phase mixture were clarified. (author)

  9. Fuel gas production by microwave plasma in liquid

    International Nuclear Information System (INIS)

    Nomura, Shinfuku; Toyota, Hiromichi; Tawara, Michinaga; Yamashita, Hiroshi; Matsumoto, Kenya

    2006-01-01

    We propose to apply plasma in liquid to replace gas-phase plasma because we expect much higher reaction rates for the chemical deposition of plasma in liquid than for chemical vapor deposition. A reactor for producing microwave plasma in a liquid could produce plasma in hydrocarbon liquids and waste oils. Generated gases consist of up to 81% hydrogen by volume. We confirmed that fuel gases such as methane and ethylene can be produced by microwave plasma in liquid

  10. The speed of sound in a gas-vapour bubbly liquid.

    Science.gov (United States)

    Prosperetti, Andrea

    2015-10-06

    In addition to the vapour of the liquid, bubbles in cavitating flows usually contain also a certain amount of permanent gas that diffuses out of the liquid as they grow. This paper presents a simplified linear model for the propagation of monochromatic pressure waves in a bubbly liquid with these characteristics. Phase change effects are included in detail, while the gas is assumed to follow a polytropic law. It is shown that even a small amount of permanent gas can have a major effect on the behaviour of the system. Particular attention is paid to the low-frequency range, which is of special concern in flow cavitation. Numerical results for water and liquid oxygen illustrate the implications of the model.

  11. Gas liquid sampling for closed canisters in KW Basin - test plan

    International Nuclear Information System (INIS)

    Pitkoff, C.C.

    1995-01-01

    Test procedures for the gas/liquid sampler. Characterization of the Spent Nuclear Fuel, SNF, sealed in canisters at KW-Basin is needed to determine the state of storing SNF wet. Samples of the liquid and the gas in the closed canisters will be taken to gain characterization information. Sampling equipment has been designed to retrieve gas and liquid from the closed canisters in KW basin. This plan is written to outline the test requirements for this developmental sampling equipment

  12. Gas condensate--raw material for producing liquid paraffin hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Aliyeva, R.B.; Alikishi-Zade, G.Yu.; Kuliyev, A.M.; Leonidov, A.N.; Pereverzev, A.N.

    1980-01-01

    The problem of efficient utilization of gas condensates as raw material for removal of a valuable product, liquid paraffins, is examined. A classification of gas condensates is given which is used as raw material for removing these hydrocarbons: gas condensate with high content of n-alkanes (25-40 mass percent), with average content (18-25 mass percent), with low content (12-18 mass percent), light weight fractions compositions, which do not contain fractions up to 200/sup 0/, and also, content ofless than 12% n-alkanes. Gas condensate I-III groups are 30% of the total reserve of gas condensate. Liquid paraffins hydrocarbons, produced from fractions of diesel fuel, which has been removed from Shatlyk gas condensate under conditions which simulate virtual processes of caramide deparaffinization meet all requirements without additional refining.

  13. Generation and characterization of gas bubbles in liquid metals

    International Nuclear Information System (INIS)

    Eckert, S.; Gerbeth, G.; Witke, W.

    1996-01-01

    There is an ongoing research performed in the RCR on local transport phenomena in turbulent liquid metal (LM) duct flows exposed to external magnetic fields. In this context so-called MHD flow phenomena can be observed, which are unknown in usual hydraulic engineering. The field of interest covers also the influence of magnetic fields on the behaviour of liquid metal - gas mixtures. Profound knowledge on these LMMHD two-phase flow plays an important role in a variety of technological applications, in particular, in the design of Liquid-Metal MHD generators or for several metallurgical processes employing gas-stirred reactors. However, the highly empirical nature of two-phase flow analysis gives little hope for the prediction of MHD two-phase flows without extensive experimental data. A summary is given about the authors research activities focussing on two directions: (a) Momentum transfer between gas and liquid metal in a bubbly flow regime to investigate the influence of the external magnetic field on the velocity slip ration S (b) Peculiarities of the MHD turbulence to use small gas bubbles as local tracers in order to study the turbulent mass transfer

  14. Study on gas-liquid loop reactors with annular bubbling

    International Nuclear Information System (INIS)

    Fei, L.M.; Wang, S.X.; Wu, X.Q.; Lu, D.W.

    1987-01-01

    Bubbling column with draft tube is one of nearly developed reactor. On the background of hydrocarbon oxidations and biochemical engineerings, it has been widely used in chemical industry due to the well characteristics of mass and heat transfer. In this paper, the characteristics of fluid flow, such as gas hold-up, backmixing and mass transfer referred to the liquid volume were measured in a gas-liquid loop reactor with annular bubbling. Different materials - water, alcohol and oi l- were used in the study in measuring the gas hold-up in the annular of the reactor

  15. Plasmachemical oxidation processes in a hybrid gas-liquid electrical discharge reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lukes, Petr; Locke, Bruce R [Department of Chemical and Biomedical Engineering, FAMU-FSU College of Engineering, Florida State University, 2525 Pottsdamer Street, Tallahassee, Florida (United States)

    2005-11-21

    Oxidation processes induced in water by pulsed electrical discharges generated simultaneously in the gas phase in close proximity to the water surface and directly in the liquid were investigated in a hybrid series gas-liquid electrical discharge reactor. The mechanism of phenol degradation was studied through its dependence on the gas phase and liquid phase compositions using pure argon and oxygen atmospheres above the liquid and different initial pH values in the aqueous solution. Phenol degradation was significantly enhanced in the hybrid-series reactor compared with the phenol removal by the single-liquid phase discharge reactor. Under an argon atmosphere the mechanism of phenol degradation was mainly caused by the electrophilic attack of OH{center_dot} radicals produced by the liquid phase discharge directly in water and OH{center_dot} radicals produced by the gas phase discharge at the gas-liquid interface. Under an oxygen atmosphere the formation of gaseous ozone dominated over the formation of OH{center_dot} radicals, and the contribution of the gas phase discharge in this case was determined mainly by the dissolution of gaseous ozone into the water and its subsequent interaction with phenol. At high pH phenol was degraded, in addition to the direct attack by ozone, also through indirect reactions of OH{center_dot} radicals formed via a peroxone process by the decomposition of dissolved ozone by hydrogen peroxide produced by the liquid phase discharge. Such a mechanism was proved by the detection of cis,cis-muconic acid and pH-dependent degradation of phenol, which resulted in significantly higher removal of phenol from alkaline solution observed under oxygen atmosphere than in argon.

  16. Plasmachemical oxidation processes in a hybrid gas-liquid electrical discharge reactor

    International Nuclear Information System (INIS)

    Lukes, Petr; Locke, Bruce R

    2005-01-01

    Oxidation processes induced in water by pulsed electrical discharges generated simultaneously in the gas phase in close proximity to the water surface and directly in the liquid were investigated in a hybrid series gas-liquid electrical discharge reactor. The mechanism of phenol degradation was studied through its dependence on the gas phase and liquid phase compositions using pure argon and oxygen atmospheres above the liquid and different initial pH values in the aqueous solution. Phenol degradation was significantly enhanced in the hybrid-series reactor compared with the phenol removal by the single-liquid phase discharge reactor. Under an argon atmosphere the mechanism of phenol degradation was mainly caused by the electrophilic attack of OH· radicals produced by the liquid phase discharge directly in water and OH· radicals produced by the gas phase discharge at the gas-liquid interface. Under an oxygen atmosphere the formation of gaseous ozone dominated over the formation of OH· radicals, and the contribution of the gas phase discharge in this case was determined mainly by the dissolution of gaseous ozone into the water and its subsequent interaction with phenol. At high pH phenol was degraded, in addition to the direct attack by ozone, also through indirect reactions of OH· radicals formed via a peroxone process by the decomposition of dissolved ozone by hydrogen peroxide produced by the liquid phase discharge. Such a mechanism was proved by the detection of cis,cis-muconic acid and pH-dependent degradation of phenol, which resulted in significantly higher removal of phenol from alkaline solution observed under oxygen atmosphere than in argon

  17. Effect of Gas- and Liquid-injection Methods on Formation of Bubble and Liquid Slug at Merging Micro T-junction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Kyoung [Kyungnam Univ., Changwon (Korea, Republic of); Lee, Chi Young [Pukyong Nat’l Univ., Busan (Korea, Republic of)

    2016-04-15

    In the present experimental study, the effect of gas- and liquid-injected methods on the formation of bubble and liquid slug at the merging micro T-junction of a square microchannel with dimensions 600 μm × 600 μm was investigated. Nitrogen and water were used as test fluids. The superficial velocities of the liquid and gas were in the range of 0.05 - 1 m/s, and 0.1 - 1 m/s, respectively, where the Taylor flow was observed. The bubble length, liquid slug length, bubble velocity, and bubble generation frequency were measured by analyzing the images captured using a high-speed camera. Under similar inlet superficial velocity conditions, in the case of gas injection to the main channel at the merging T-junction (T{sub g}as-liquid), the lengths of the bubble and liquid slug were longer, and the bubble generation frequency was lower than in the case of liquid injection to the main channel at the merging T-junction (T{sub l}iquid-gas). On the other hand, in both cases, the bubble velocity was almost the same. The previous correlation proposed using experimental data for T{sub l}iquid-gas had predicted the present experimental data of bubble length, bubble velocity, liquid slug length, and bubble generation frequency for T{sub g}as-liquid to be ~24%, ~9%, ~39%, ~55%, respectively.

  18. Liquid Natural Gas

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    After a brief introduction on the origins of the Liquid Natural Gas (LNG) industry the production and transportation of LNG are discussed. Special attention is paid to the importance of the safety aspect during every activity or handling of LNG. Next the most important trade flows for LNG are dealt with. Two zones can be distinguished: the western part of the Pacific and the Atlantic basin. Subsequently the main aspects of a LNG-project are mentioned, as well as the success factors. Finally the prospects for the LNG-industry are reviewed. 11 figs

  19. Natural gas purification using supported ionic liquid membrane

    NARCIS (Netherlands)

    Althuluth, M.A.M.; Overbeek, J.P.; Wees, H.J.; Zubeir, L.F.; Haije, W.G.; Berrouk, A.S.; Peters, C.J.; Kroon, M.C.

    2015-01-01

    This paper examines the possibility of the application of a supported ionic liquid membrane (SILM) for natural gas purification. The ionic liquid (IL) 1-ethyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([emim][FAP]) was impregnated successfully in the ¿-alumina layer of a tubular

  20. Study on Gas-liquid Falling Film Flow in Internal Heat Integrated Distillation Column

    Science.gov (United States)

    Liu, Chong

    2017-10-01

    Gas-liquid internally heat integrated distillation column falling film flow with nonlinear characteristics, study on gas liquid falling film flow regulation control law, can reduce emissions of the distillation column, and it can improve the quality of products. According to the distribution of gas-liquid mass balance internally heat integrated distillation column independent region, distribution model of heat transfer coefficient of building internal heat integrated distillation tower is obtained liquid distillation falling film flow in the saturated vapour pressure of liquid water balance, using heat transfer equation and energy equation to balance the relationship between the circulating iterative gas-liquid falling film flow area, flow parameter information, at a given temperature, pressure conditions, gas-liquid flow falling film theory makes the optimal parameters to achieve the best fitting value with the measured values. The results show that the geometric gas-liquid internally heat integrated distillation column falling film flow heat exchange area and import column thermostat, the average temperature has significant. The positive correlation between the heat exchanger tube entrance due to temperature difference between inside and outside, the heat flux is larger, with the increase of internal heat integrated distillation column temperature, the slope decreases its temperature rise, which accurately describes the internal gas-liquid heat integrated distillation tower falling film flow regularity, take appropriate measures to promote the enhancement of heat transfer. It can enhance the overall efficiency of the heat exchanger.

  1. Drift-flux parameters for upward gas flow in stagnant liquid

    International Nuclear Information System (INIS)

    Kataoka, Yoshiyuki; Suzuki, Hiroaki; Murase, Michio

    1987-01-01

    The drift-flux model is widely used for gas-liquid two phase flow analysis, because it is applicable to various flow patterns and a wide range of void fractions. The drift-flux parameters for upward gas flow in stagnant liquid, however, have not been well examined. In this study, the distribution parameter C o and the drift velocity V gj for stagnant liquid were derived from the void fraction correlation and boundary conditions of drift-flux parameters, and then compared with C o and V gj for high liquid velocities. Also using the two region model where a circular flow area was divided into an inner region of cocurrent up-flow and an outer annulus region of liquid down flow, C o and V gj for stagnant liquid and for high liquid velocity were compared. The results showed that C o values for stagnant liquid were larger than values for high liquid velocity, while V gj values were almost the same for both cases. (author)

  2. Influence of Gas-Liquid Interface on Temperature Wave of Pulsating Heat Pipe

    Directory of Open Access Journals (Sweden)

    Ying Zhang

    2018-01-01

    Full Text Available The influence of the interface on the amplitude and phase of the temperature wave and the relationship between the attenuation of the temperature wave and the gas-liquid two-phase physical parameters are studied during the operation of the pulsating heat pipe. The numerical simulation shows that the existence of the phase interface changes the direction of the temperature gradient during the propagation of the temperature wave, which increases the additional “thermal resistance.” The relative size of the gas-liquid two-phase thermal conductivity affects the propagation direction of heat flow at phase interface directly. The blockage of the gas plug causes hysteresis in the phase of the temperature wave, the relative size of the gas-liquid two-phase temperature coefficient will gradually increase the phase of the temperature wave, and the time when the heat flow reaches the peak value is also advanced. The attenuation of the temperature wave is almost irrelevant to the absolute value of the density, heat capacity, and thermal conductivity of the gas-liquid two phases, and the ratio of the thermal conductivity of the gas-liquid two phases is related. When the temperature of the heat pipe was changed, the difference of heat storage ability between gas and liquid will lead to the phenomenon of heat reflux and becomes more pronounced with the increases of the temperature wave.

  3. Liquid-gas phase transition and isospin fractionation in intermediate energy heavy ion collisions

    International Nuclear Information System (INIS)

    Xing Yongzhong; Liu Jianye; Guo Wenjun

    2004-01-01

    The liquid-gas phase transition in the heavy ion collisions and nuclear matter has been an important topic and got achievements, such as, based on the studies by H.Q. Song et al the critical temperature of liquid-gas phase transition enhances with increasing the mass of system and reduces as the increase of the neutron proton ratio of system. As authors know that both the liquid-gas phase transition and the isospin fractionation occur in the spinodal instability region at the nuclear density below the normal nuclear density. In particular, these two dynamical processes lead to the separation of nuclear matter into the liquid phase and gas phase. In this case to compare their dynamical behaviors is interested. The authors investigate the dependence of isospin fractionation degree on the mass and neutron proton ratio of system by using the isospin dependent quantum molecular dynamics model. The authors found that the degree of isospin fractionation (N/Z) n /(N/Z) imf decreases with increasing the mass of the system. This is just similar to the enhance of the critical temperature of liquid-gas phase transition T c as the increase of system mass. Because the enhance of T c is not favorable for the liquid-gas transition taking place, which reduces the isospin fractionation process and leads to decrease of (N/Z) n /(N/Z) imf . However the degree of isospin fractionation enhances with increasing the neutron proton ratio of the system. It is just corresponding to the reduce of T c of the liquid-gas phase transition as the increase of the isospin fractionation of the system. Because the reduce of T c enhances the liquid-gas phase transition process and also prompts the isospin fractionation process leading the increase of the isospin fractionation degree. To sum up, there are very similar dynamical behaviors for the degree of isospin fractionation and the critical temperature of the liquid-gas phase transition. So dynamical properties of the liquid-gas phase transition can

  4. Absorption of Flue-Gas Components by Ionic Liquids

    DEFF Research Database (Denmark)

    Kolding, Helene; Thomassen, Peter Langelund; Mossin, Susanne

    2014-01-01

    Gas separation by ionic liquids (ILs) is a promising new research field with several potential applications of industrial interest. Thus cleaning of industrial off gases seems to be attractive by use of ILs and Supported Ionic Liquid Phase (SILP) materials. The potential of selected ILs...

  5. Synthesis gas production via hybrid steam reforming of natural gas and bio-liquids

    NARCIS (Netherlands)

    Balegedde Ramachandran, P.

    2013-01-01

    This thesis deals with (catalytic) steam reforming of bio-liquids for the production of synthesis gas. Glycerol, both crude from the biodiesel manufacturing and refined, and pyrolysis oil are tested as bio-based feedstocks. Liquid bio-based feeds could be preferred over inhomogeneous fibrous solid

  6. Canadian natural gas liquids : market outlook 2000 - 2010

    International Nuclear Information System (INIS)

    Gill, L.; Mortensen, P.

    2001-01-01

    This study provides a comprehensive analysis of the availability of Canadian natural gas liquids. The analysis was developed from production profiles and gas compositions for individual gas pools and takes into account the effects of market factors. On the demand side, the effects of new infrastructure and changes in corporate structures have been evaluated. The study was initiated at a time when energy prices were stable and the major concern was to see how the addition of the Alliance pipeline, the Aux Sable gas processing plant, the Empress V straddle plant and the Nova/UCC E3 ethylene plant would affect the Canadian liquids business. The study was complicated by the advent of unexpected factors affecting the supply and demand of natural gas liquids (NGLs). These included extremely high prices for natural gas, an apparent inability of the supply basin to respond to the high gas prices with increased supply, and the very high electricity costs in Alberta. The weak supply of NGLs coincides with the increase in ethane demand from the start-up of Alberta's fourth ethylene facility and the addition of the high vapour pressure Alliance pipeline. This weak supply suggests there will be an ethane shortage for at least the next few years. The longer term outlook, however, is less certain and will require an analysis of the outlook for gas production, gas composition and NGL extraction capacity. This study developed two forecasts for natural gas prices. Both presume rising gas demand across North America driven by increased gas use for power generation. The Low Case assumes modest growth in domestic Canadian gas demand and the High case predicts strong growth in domestic demand as higher levels of exports to the United States, resulting in a doubling in growth for Canadian gas production from 2000-2015 compared to the Low Case. Both High and Low Case scenarios suggest that prices will decline from current levels so that Alberta plant gate prices fall by 2005 and will then

  7. Canadian natural gas liquids : market outlook 2000 - 2010

    Energy Technology Data Exchange (ETDEWEB)

    Gill, L.; Mortensen, P.

    2001-04-01

    This study provides a comprehensive analysis of the availability of Canadian natural gas liquids. The analysis was developed from production profiles and gas compositions for individual gas pools and takes into account the effects of market factors. On the demand side, the effects of new infrastructure and changes in corporate structures have been evaluated. The study was initiated at a time when energy prices were stable and the major concern was to see how the addition of the Alliance pipeline, the Aux Sable gas processing plant, the Empress V straddle plant and the Nova/UCC E3 ethylene plant would affect the Canadian liquids business. The study was complicated by the advent of unexpected factors affecting the supply and demand of natural gas liquids (NGLs). These included extremely high prices for natural gas, an apparent inability of the supply basin to respond to the high gas prices with increased supply, and the very high electricity costs in Alberta. The weak supply of NGLs coincides with the increase in ethane demand from the start-up of Alberta's fourth ethylene facility and the addition of the high vapour pressure Alliance pipeline. This weak supply suggests there will be an ethane shortage for at least the next few years. The longer term outlook, however, is less certain and will require an analysis of the outlook for gas production, gas composition and NGL extraction capacity. This study developed two forecasts for natural gas prices. Both presume rising gas demand across North America driven by increased gas use for power generation. The Low Case assumes modest growth in domestic Canadian gas demand and the High case predicts strong growth in domestic demand as higher levels of exports to the United States, resulting in a doubling in growth for Canadian gas production from 2000-2015 compared to the Low Case. Both High and Low Case scenarios suggest that prices will decline from current levels so that Alberta plant gate prices fall by 2005 and will

  8. Abnormal liquid loading in gas wells of the Samandepe Gasfield in Turkmenistan and countermeasures

    Directory of Open Access Journals (Sweden)

    Peijun Zhang

    2015-10-01

    Full Text Available With complicated formation mechanisms, liquid loading in gas wells during gasfield development may significantly affect the productivity of gas wells and the ultimate recovery rate. Dynamic monitoring data of the Samandepe Gasfield in Turkmenistan shows that liquid loading can be found extensively in gas wells. Their formation mechanisms and negative impacts on gasfield development severely restrict the productivity enhancement of this gasfield. With their origins taken into consideration, liquid loads in gas wells were classified into three types: formation water, condensed liquid, and external liquid. By using the hydrostatic pressure gradient method and through PLT monitoring, properties of liquid loads in the Samandepe Gasfield were determined. In addition, formation mechanisms related to liquid loading in gas wells were obtained through analyses of critical fluid-carrying capacities and by using gas-reservoir production data. The following findings were obtained. Liquid loading was commonly found in this gas well with majority of reservoir formations in lower well intervals flooded. However, the formation mechanisms for these liquid loads are different from those of other gasfields. Due to long-term shut-down of gas wells, killing fluids precipitated and pores in lower reservoir formations were plugged. As a result, natural gas had no access to boreholes, killing fluids were impossibly carried out of the borehole. Instead, the killing fluid was detained at the bottomhole to generate liquid load and eliminate the possibility of formation water coning. Moreover, since the gasfield was dominated by block reservoirs with favorable physical properties and connectivity, impacts of liquid load on gasfield development were insignificant. Thus, to enhance the recovery rate of the Samandepe Gasfield significantly, it is necessary to expand the gasfield development scale and strengthen the development of marginal gas reservoirs.

  9. Nonequilibrium Thermodynamics of Hydrate Growth on a Gas-Liquid Interface

    Science.gov (United States)

    Fu, Xiaojing; Cueto-Felgueroso, Luis; Juanes, Ruben

    2018-04-01

    We develop a continuum-scale phase-field model to study gas-liquid-hydrate systems far from thermodynamic equilibrium. We design a Gibbs free energy functional for methane-water mixtures that recovers the isobaric temperature-composition phase diagram under thermodynamic equilibrium conditions. The proposed free energy is incorporated into a phase-field model to study the dynamics of hydrate formation on a gas-liquid interface. We elucidate the role of initial aqueous concentration in determining the direction of hydrate growth at the interface, in agreement with experimental observations. Our model also reveals two stages of hydrate growth at an interface—controlled by a crossover in how methane is supplied from the gas and liquid phases—which could explain the persistence of gas conduits in hydrate-bearing sediments and other nonequilibrium phenomena commonly observed in natural methane hydrate systems.

  10. [Automated analysis of bacterial preparations manufactured on automatic heat fixation and staining equipment].

    Science.gov (United States)

    2012-01-01

    Heat fixation of preparations was made in the fixation bath designed by EMKO (Russia). Programmable "Emkosteiner" (EMKO, Russia) was used for trial staining. Reagents set Micko-GRAM-NITsF was applied for Gram's method of staining. It was demostrated that automatic smear fixation equipment and programmable staining ensure high-quality imaging (1% chromaticity variation) good enough for standardization of Gram's staining of microbial preparations.

  11. Gas-liquid two-phase flow behavior in terrain-inclined pipelines for gathering transport system of wet natural gas

    DEFF Research Database (Denmark)

    Yang, Yan; Li, Jingbo; Wang, Shuli

    2018-01-01

    The Volume of Fluid method and Re-Normalisation Group (RNG) k-ε turbulence model were employed to predict the gas-liquid two-phase flow in a terrain-inclined pipeline with deposited liquids. The simulation was carried out in a 22.5 m terrain-inclined pipeline with a 150 mm internal diameter...... on the liquid level under the suction force which caused by the negative pressure around the elbow, and then it touched to the top of the pipe. When the liquid blocked the pipe, the pressure drop between the upstream and downstream of the elbow increased with the increase of the gas velocity. At larger gas...

  12. Application of Ionic Liquids in Amperometric Gas Sensors.

    Science.gov (United States)

    Gębicki, Jacek; Kloskowski, Adam; Chrzanowski, Wojciech; Stepnowski, Piotr; Namiesnik, Jacek

    2016-01-01

    This article presents an analysis of available literature data on metrological parameters of the amperometric gas sensors containing ionic liquids as an electrolyte. Four mechanism types of signal generation in amperometric sensors with ionic liquid are described. Moreover, this article describes the influence of selected physico-chemical properties of the ionic liquids on the metrological parameters of these sensors. Some metrological parameters are also compared for amperometric sensors with GDE and SPE electrodes and with ionic liquids for selected analytes.

  13. Numerical simulation of the gas-liquid interaction of a liquid jet in supersonic crossflow

    Science.gov (United States)

    Li, Peibo; Wang, Zhenguo; Sun, Mingbo; Wang, Hongbo

    2017-05-01

    The gas-liquid interaction process of a liquid jet in supersonic crossflow with a Mach number of 1.94 was investigated numerically using the Eulerian-Lagrangian method. The KH (Kelvin-Helmholtz) breakup model was used to calculate the droplet stripping process, and the secondary breakup process was simulated by the competition of RT (Rayleigh-Taylor) breakup model and TAB (Taylor Analogy Breakup) model. A correction of drag coefficient was proposed by considering the compressible effects and the deformation of droplets. The location and velocity models of child droplets after breakup were improved according to droplet deformation. It was found that the calculated spray features, including spray penetration, droplet size distribution and droplet velocity profile agree reasonably well with the experiment. Numerical results revealed that the streamlines of air flow could intersect with the trajectory of droplets and are deflected towards the near-wall region after they enter into spray zone around the central plane. The analysis of gas-liquid relative velocity and droplet deformation suggested that the breakup of droplets mainly occurs around the front region of the spray where gathered a large number of droplets with different sizes. The liquid trailing phenomenon of jet spray which has been discovered by the previous experiment was successfully captured, and a reasonable explanation was given based on the analysis of gas-liquid interaction process.

  14. Measurement of gas-liquid two-phase flow around horizontal tube bundle using SF6-water. Simulating high-pressure high-temperature gas-liquid two-phase flow of PWR/SG secondary coolant side at normal pressure

    International Nuclear Information System (INIS)

    Ishikawa, Atsushi; Imai, Ryoj; Tanaka, Takahiro

    2014-01-01

    In order to improve prediction accuracy of analysis code used for design and development of industrial products, technology had been developed to create and evaluate constitutive equation incorporated in analysis code. The experimental facility for PWR/SG U tubes part was manufactured to measure local void fraction and gas-liquid interfacial velocity with forming gas-liquid upward two-phase flow simulating high-pressure high-temperature secondary coolant (water-steam) rising vertically around horizontal tube bundle. The experimental facility could reproduce flow field having gas-liquid density ratio equivalent to real system with no heating using SF6 (Sulfur Hexafluoride) gas at normal temperature and pressure less than 1 MPa, because gas-liquid density ratio, surface tension and gas-liquid viscosity ratio were important parameters to determine state of gas-liquid two-phase flow and gas-liquid density ratio was most influential. Void fraction was measured by two different methods of bi-optical probe and conductivity type probe. Test results of gas-liquid interfacial velocity vs. apparent velocity were in good agreement with existing empirical equation within 10% error, which could confirm integrity of experimental facility and appropriateness of measuring method so as to set up original constitutive equation in the future. (T. Tanaka)

  15. Mechanical properties of 5083 aluminium welds after manual and automatic pulsed gas metal arc welding using E5356 filler

    CSIR Research Space (South Africa)

    Mutombo, K

    2010-01-01

    Full Text Available Semi-automatic and automatic pulsed gas metal arc welding (GMAW) of aluminium alloy 5083 with ER5356 filler wire causes considerable softening in the weld. The tensile strength of dressed automatic welds approaches that of the base metal...

  16. Long liquid slugs in stratified gas/liquid flow in horizontal and slightly inclined pipes

    NARCIS (Netherlands)

    Kadri, U.

    2009-01-01

    Long liquid slugs reaching several hundreds pipe diameter may appear when transporting gas and liquid in horizontal and near horizontal pipes. The long slugs cause system vibration and separation difficulties that may lead to operational failures. Identifying and predicting the time and length

  17. Analysing Gas-Liquid Flow in PEM Electrolyser Micro-Channels

    DEFF Research Database (Denmark)

    Lafmejani, Saeed Sadeghi; Olesen, Anders Christian; Kær, Søren Knudsen

    2016-01-01

    and are fairly expensive. One means of increasing the hydrogen yield to cost ratio of such systems, is to increase the operating current density. However, at high current densities, management of heat and mass transfer in the anode current collector and channel becomes crucial. This entails that further...... understanding of the gas-liquid flow in both the porous media and the channel is necessary for insuring proper oxygen, water and heat management of the electrolysis cell. In this work, the patterns of vertical upward gas-liquid flow in a 5×1×94 mm micro-channel are experimentally analysed. A sheet of titanium...... felt is used as a permeable wall for permeation of air through a column of water similar to the phenomenon encountered at the anode. The transparent setup is operated ex-situ and the gas-liquid flow regimes are identified using a camera....

  18. Optics of Confined Liquid Crystals for Gas Detection

    Science.gov (United States)

    Charles, William; Carrozzi, Daniel; Vigilia, Lee Anne; Wang, Xiaoyurui; Guzman, Violet; Shibayev, Petr; Fordham University Students of Undergraduate Physics Team

    Cholesteric liquid crystals (CLCs) of a wide range of viscosities were studied experimentally in relation to their use as gas sensors and sensors of volatile organic compounds (VOCs), specifically ethanol, cyclohexane, toluene, acetic acid, and pyridine. CLCs were obtained by mixing low molar mass liquid crystals (MBBA and cholesterol derivatives with siloxane based oligomers). The droplets of CLCs were placed in containers with controlled atmospheres. The shift of the selective reflection band, predominantly from shorter to longer wavelengths, and the color changes were observed in the CLC illuminated by light coming from the various directions. Visible optical changes were observed in droplets with viscosities of CLCs ranging from c.a. 4 Pa*s to 105 Pa*s. The most responsive droplets in which the shift of the selective reflection band occurs at lower concentrations of VOCs were prepared from CLC mixtures with the lowest viscosities. Higher viscosities of CLCs lead to a slower response to VOCs, but the rate of response is different for each pair of VOC and CLC with a certain viscosity. This finding opens a possibility for selective detection of VOCs by CLCs with different viscosities. The mechanism of VOCs diffusion, interaction with CLC matrix and optical changes is discusse

  19. Solids precipitation in crude oils, gas-to-liquids and their blends

    Science.gov (United States)

    Ramanathan, Karthik

    Gas-to-liquids (GTL) liquids are obtained from syngas by the Fischer-Tropsch synthesis. The blending of GTL liquids produced from natural gas/coal reserves and crude oils is a possibility in the near future for multiple reasons. Solids precipitation is a major problem in pipelines and refineries leading to significant additional operating costs. The effect of the addition of a paraffinic GTL liquid to crude oils on solids precipitation was investigated in this study. A Fourier transform infrared (FT-IR) spectroscopic technique was used to obtain solid-liquid equilibria (SLE) data for the various samples. The SLE of multiple systems of model oils composed of n-alkanes was investigated preliminarily. Blends of a model oil simulating a GTL liquid composition and a crude oil showed that the wax precipitation temperature (WPT) decreased upon blending. Three crude oils from different geographic regions (Alaskan North Slope, Colorado and Venezuela) and a laboratory-produced GTL liquid were used in the preparation of blends with five different concentrations of the GTL liquid. The wax precipitation temperatures of the blends were found to decrease with the increasing addition of the GTL liquid for all the oils. This effect was attributed to the solvent effect of the low molecular weight-paraffinic GTL liquid on the crude oils. The weight percent solid precipitated that was estimated as a function of temperature did not show a uniform trend for the set of crude oils. The asphaltene onset studies done on the blends with near-infrared spectroscopy indicated that the addition of GTL liquid could have a stabilizing effect on the asphaltenes in some oils. Analytical techniques such as distillation, solvent separation, HPLC, GC, and GPC were used to obtain detailed composition data on the samples. Two sets of compositional data with 49 and 86 pseudo-components were used to describe the three crude oils used in the blending work. The wax precipitation was calculated using a

  20. On the development of automatic sample preparation devices

    International Nuclear Information System (INIS)

    Oesselmann, J.

    1987-01-01

    Modern mass spectrometers for stable isotope analysis offer accurate isotope ratio results from gaseous samples (CO 2 , N 2 , H 2 , SO 2 ) in a completely automated fashion. However, most samples of interest either are associated with contaminant gases or the gas has to be liberated by a chemical procedure prior to measurement. In most laboratories this sample preparation step is performed manually. As a consequence, sample throughput is rather low and - despite skilful operation - the preparation procedure varies slightly from one sample to the next affecting mainly the reproducibility of the data. (author)

  1. An analysis of the falling film gas-liquid reactor

    NARCIS (Netherlands)

    Davis, E.J.; Ouwerkerk-Dijkers, van M.P.; Venkatesh, S.

    1979-01-01

    A mathematical model of the falling film reactor is developed to predict the conversion and temperature distribution in the reactor as a function of the gas and liquid flow rates, physical properties, the feed composition of the reactive gas and carrier gas and other parameters of the system.

  2. Gas-liquid phase coexistence in a tetrahedral patchy particle model

    International Nuclear Information System (INIS)

    Romano, Flavio; Tartaglia, Piero; Sciortino, Francesco

    2007-01-01

    We evaluate the location of the gas-liquid coexistence line and of the associated critical point for the primitive model for water (PMW), introduced by Kolafa and Nezbeda (1987 Mol. Phys. 61 161). Besides being a simple model for a molecular network forming liquid, the PMW is representative of patchy proteins and novel colloidal particles interacting with localized directional short-range attractions. We show that the gas-liquid phase separation is metastable, i.e. it takes place in the region of the phase diagram where the crystal phase is thermodynamically favoured, as in the case of particles interacting via short-range attractive spherical potentials. We do not observe crystallization close to the critical point. The region of gas-liquid instability of this patchy model is significantly reduced as compared to that from equivalent models of spherically interacting particles, confirming the possibility of observing kinetic arrest in a homogeneous sample driven by bonding as opposed to packing. (fast track communication)

  3. An automatic sample changer for use on the SNS

    International Nuclear Information System (INIS)

    1982-10-01

    A design for an Automatic Room Temperature Sample Changer suitable for any completely contained sample, gas, liquid or solid, has been produced. Samples can be moved in any sequence into the neutron beam. The design was evolved primarily to suit SNS instruments. A prototype was constructed specifically for the LAD spectrometer having ten sample positions. The accuracy of the sample positioning was determined. (author)

  4. Heat transfer by liquids in suspension in a turbulent gas stream (1960)

    International Nuclear Information System (INIS)

    Grison, E.; Commissariat a l'Energie Atomique, Saclay

    1960-01-01

    The introduction of a small volume of liquid into a turbulent gas stream used as cooling agent improves considerably the heat transfer coefficient of the gas. When the turbulent regime is established, one observes in a cylindrical tube two types of flow whether the liquid wets or does not wet the wall. In the first case, one gets on the wall an annular liquid film and droplets in suspension are in the gas stream. In the second case, a fog of droplets is formed without any liquid film on the wall. Experiments were performed with the following mixtures: water-hydrogen, water-nitrogen, ethanol-nitrogen (wetting liquids) introduced into a stainless steel tube of 4 mm ID, electrically heated on 320 mm of length. We varied the gas flow rate (Reynolds until 50000), the rate of the liquid flow rate to gas flow rate (until 15), the pressure (until 10 kg/cm 2 ), the temperature (until the boiling point) and the heat flux (until 250 W/cm 2 ). Two types of burnout were observed. A formula of correlation of the burnout heat flux is given. Making use of the analogy between mass transfer and heat transfer, a dimensionless formula of correlation of the local heat transfer coefficients is established. (author) [fr

  5. Poly(ionic liquid)/Ionic Liquid Ion-Gels with High "Free" Ionic Liquid Content: Platform Membrane Materials for CO2/Light Gas Separations.

    Science.gov (United States)

    Cowan, Matthew G; Gin, Douglas L; Noble, Richard D

    2016-04-19

    -films (ca. 100-nm-thick active layer). Traditional polymeric membrane materials are limited by a trade-off between permeability and selectivity empirically described by the "Robeson upper bound"-placing the desired membrane properties beyond reach. Therefore, the investigation of advanced and composite materials that can overcome the limitations of traditional polymeric materials is the focus of significant academic and industrial research. In particular, there has been substantial work on ionic-liquid (IL)-based materials due to their gas transport properties. This review provides an overview of our collaborative work on developing poly(ionic liquid)/ionic liquid (PIL/IL) ion-gel membrane technology. We detail developmental work on the preparation of PIL/IL composites and describe how this chemical technology was adapted to allow the roll-to-roll processing and preparation of membranes with defect-free active layers ca. 100 nm thick, CO2 permeances of over 6000 GPU, and CO2/N2 selectivity of ≥20-properties with the potential to reduce the cost of CO2 removal from coal-fired power plant flue gas to ca. $15 per ton of CO2 captured. Additionally, we examine the materials developments that have produced advanced PIL/IL composite membranes. These advancements include cross-linked PIL/IL blends, step-growth PIL/IL networks with facilitated transport groups, and PIL/IL composites with microporous additives for CO2/CH4 separations.

  6. Huff 'n puff to revaporize liquid dropout in an Omani gas field

    Energy Technology Data Exchange (ETDEWEB)

    Al-Wadhahi, M.; Boukadi, F.H.; Al-Bemani, A.; Al-Maamari, R.; Al-Hadrami, H. [Department of Petroleum and Chemical Engineering, Sultan Qaboos University, P.O. Box 33, Al-Khod 123 (Oman)

    2007-01-15

    In this study, Huff 'n Puff technique is used as a production mechanism to revaporize liquid dropout in the Saih Rawl retrograde condensate gas field, Oman. During the huff cycle, a number of wells were shut in to achieve revaporization. The same wells were put on stream, during the puff cycle. Liquid dropout induced a mechanical skin around the wellbore and hampered gas production capabilities but has been revaporized through pressurization. The pressure buildup in the rich-gas condensate reservoir was due to a cross flow originating from a deeper highly pressurized lean-gas bearing formation. The pressure communication was taking place through the wellbore during shut-in cycles. A compositional simulation model was used to confirm the theory of condensate revaporization. Simulation results indicated that Huff 'n Puff is a viable production technique. The technique improved gas deliverability and enhanced gas-liquid production by minimizing the skin caused by gas-liquid dropout. (author)

  7. An analytical study by gas liquid chromatography and radiochromatography of tritium labelled lebaycid; Estudio Analitico del proceso de sistesis del lebaycid marcado contritio por cromatogria gas liquido y radiocromatografia

    Energy Technology Data Exchange (ETDEWEB)

    Perez Garcia, M M

    1969-07-01

    The stability and purity of the syntheses products of Lebaycid: 0,0 dime thylfosfochlorothionate and 4 methyl-thio-m-cresol were investigated by gas liquid chromatography. The study on (CH{sub 3}O){sub 2} PSC1 was made in a column of Silicone SE-30, Reoplex 400 using a thermal conductivity detector. The 99,4% pure product obtained from the preparative gas chromatograph was found to be stable within the duration of the experiment: seven months. (Author) 23 refs.

  8. Hydrodynamics in a cocurrent gas-liquid trickle bed at elevated pressures

    OpenAIRE

    Wammes, W.J.A.; Middelkamp, J.; Huisman, W.J.; Huisman, W.J.; de Baas, C.M.; de Baas, C.M.; Westerterp, K.R.

    1991-01-01

    Data on design and operation of trickle beds at elevated pressures are scarce. In this study the influence of the gas density on the liquid holdup, the pressure drop, and the transition between trickle and pulse flow has been investigated in a tricklebed reactor operating up to 7.5 MPa and with nitrogen or helium as the gas phase. Gas-liquid interfacial areas have been determined up to 5.0 MPa by means of CO2 absorption from CO2/N2 gas mixtures into amine solutions. A comparison of the result...

  9. Strategic implications of gas to liquids technology for the natural gas industry

    International Nuclear Information System (INIS)

    Russell, B. J.

    1998-01-01

    A new and economical gas to liquids (GTL) technology is described that promises to substantially increase industry's ability to exploit many trillions of cubic feet of largely unmarketable reserves of natural gas. The technology turns the gas into a form that overcomes prohibitive transportation costs, avoids long-term, high-risk, take-or-pay contracts, and helps satisfy the demand for cleaner liquid products. Widespread application of GTL technology is credited with having the power to ease the burden on every segment of the petroleum industry, from exploration through petrochemicals, and into allied industries such as electric power generation. It is claimed that in situations where GTL is the only economic option, it will create an entirely new set of opportunities. Among these are the monetization of known stranded gas and the early development of remote gas discoveries or of oil discoveries associated with gas. It will cause a re-evaluation of exploration strategies by upgrading gas prospects in remote locations and new investment options to countries with shut-in gas or heavy oil or tar sand reserves. The monetization of associated gas when reinjection is no longer needed or desired could occur. Extensive applications offshore and adjacent to coastal reserves and multiple options for refiners facing heavier, higher-sulfur crude slates are possible. The outlook for Syntroleum's version of the GTL process, and the 'grant-back' provisions of Syntroleum's license agreements with companies such as Texaco, ARCO, Marathon, Criterion Catalyst, Catalytica, and ABB, giving each licensee access to the improvements of the other licencees, and the joint development agreements with these companies, were also discussed. 6 refs

  10. Coupling of a two phase gas liquid 3D Darcy flow in fractured porous media with a 1D free gas flow

    OpenAIRE

    Brenner , Konstantin; Masson , Roland; Trenty , Laurent; Zhang , Yumeng

    2015-01-01

    A model coupling a three dimensional gas liquid compositional Darcy flow in a frac-tured porous medium, and a one dimensional compositional free gas flow is presented. The coupling conditions at the interface between the gallery and the porous medium account for the molar normal fluxes continuity for each component, the gas liquid thermody-namical equilibrium, the gas pressure continuity and the gas and liquid molar fractions continuity. The fractures are represented as interfaces of codimens...

  11. Ultrasonic measurement process of the ratio volume of gas in an enclosure containing a gas-liquid mixture to the total volume of the enclosure

    International Nuclear Information System (INIS)

    Marini, J.; Heinrich, J.P.

    1983-01-01

    Ultrasonic waves with two different frequencies are sent through the fluid in the containment. Time of propagation are measured and the difference is calculated. If propagation times are identical the gas phase forms a layer on the top of the liquid phase and void fraction is determined from propagation speeds in the gas and in the liquid. If propagation times are different, part of the gas forms bubbles and void fraction is the sum of gas on top of the liquid and gas bubbles in the liquid determined separatly. Void fraction coming from the gas over the liquid is determined by waves reflected at the interface gas-liquid. Void fraction coming from the bubbles is determined by relations between the speed of ultrasonic waves and their frequency as a function of pressure and void fraction [fr

  12. Cooling of a microchannel with thin evaporating liquid film sheared by dry gas flow

    Science.gov (United States)

    Kabova, Yu O.; Kuznetsov, V. V.

    2017-11-01

    A joint motion of thin liquid film and dry gas in a microchannel is investigated numerically at different values of initial concentration of the liquid vapor in the gas phase, taking into account the evaporation process. Major factors affecting the temperature distribution in the liquid and the gas phases are as follows: transfer of heat by liquid and gas flows, heat loses due to evaporation, diffusion heat exchange. Comparisons of the numerical results for the case of the dry gas and for the case of equilibrium concentration of vapor in the gas have been carried out. It is shown that use of dry gas enhances the heat dissipation from the heater. It is found out that not only intense evaporation occurs near the heating areas, but also in both cases vapor condensation takes place below the heater in streamwise direction.

  13. Development of the krypton absorption in liquid carbon dioxide (KALC) process for HTGR off-gas reprocessing

    International Nuclear Information System (INIS)

    Glass, R.W.; Beaujean, H.W.R.; Cochran, H.D. Jr.; Haas, P.A.; Levins, D.M.; Woods, W.M.

    1975-01-01

    Reprocessing of High-Temperature Gas-Cooled Reactor (HTGR) fuel involves burning of the graphite-matrix elements to release the fuel for recovery purposes. The resulting off-gas is primarily CO 2 with residual amounts of N 2 , O 2 , and CO, together with fission products. Trace quantities of krypton-85 must be recovered in a concentrated form from the gas stream, but processes commonly employed for rare gas removal and concentration are not suitable for use with off-gas from graphite burning. The KALC (Krypton Absorption in Liquid CO 2 ) process employs liquid CO 2 as a volatile solvent for the krypton and is, therefore, uniquely suited to the task. Engineering development of the KALC process is currently under way at the Oak Ridge National Laboratory (ORNL) and the Oak Ridge Gaseous Diffusion Plant (ORGDP). The ORNL system is designed for close study of the individual separation operations involved in the KALC process, while the ORGDP system provides a complete pilot facility for demonstrating combined operations on a somewhat larger scale. Packed column performance and process control procedures have been of prime importance in the initial studies. Computer programs have been prepared to analyze and model operational performance of the KALC studies, and special sampling and in-line monitoring systems have been developed for use in the experimental facilities. (U.S.)

  14. Two-dimensional preparative liquid chromatography system for preparative separation of minor amount components from complicated natural products

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Ying-Kun, E-mail: qyk@xmu.edu.cn; Chen, Fang-Fang; Zhang, Ling-Ling; Yan, Xia; Chen, Lin; Fang, Mei-Juan; Wu, Zhen, E-mail: wuzhen@xmu.edu.cn

    2014-04-01

    Highlights: • Preparative MDLC system was developed for separation of complicated natural products. • Medium-pressure LC and preparative HPLC were connected by interface of SPE. • Automated multi-step preparative separation of 25 compounds was achieved by using this system. - Abstract: An on-line comprehensive two-dimensional preparative liquid chromatography system was developed for preparative separation of minor amount components from complicated natural products. Medium-pressure liquid chromatograph (MPLC) was applied as the first dimension and preparative HPLC as the second one, in conjunction with trapping column and makeup pump. The performance of the trapping column was evaluated, in terms of column size, dilution ratio and diameter-height ratio, as well as system pressure from the view of medium pressure liquid chromatograph. Satisfactory trapping efficiency can be achieved using a commercially available 15 mm × 30 mm i.d. ODS pre-column. The instrument operation and the performance of this MPLC × preparative HPLC system were illustrated by gram-scale isolation of crude macro-porous resin enriched water extract of Rheum hotaoense. Automated multi-step preparative separation of 25 compounds, whose structures were identified by MS, {sup 1}H NMR and even by less-sensitive {sup 13}C NMR, could be achieved in a short period of time using this system, exhibiting great advantages in analytical efficiency and sample treatment capacity compared with conventional methods.

  15. Liquid-metal-gas heat exchanger for HTGR type reactors

    International Nuclear Information System (INIS)

    Werth, G.

    1980-01-01

    The aim of this study is to investigate the heat transfer characteristics of a liquid metal heat exchanger (HE) for a helium-cooled high temperature reactor. A tube-type heat exchanger is considered as well as two direct exchangers: a bubble-type heat exchanger and a heat exchanger according to the spray principle. Experiments are made in order to determine the gas content of bubble-type heat exchangers, the dependence of the droplet diameter on the nozzle diameter, the falling speed of the droplets, the velocity of the liquid jet, and the temperature variation of liquid jets. The computer codes developed for HE calculation are structured so that they may be used for gas/liquid HE, too. Each type of HE that is dealt with is designed by accousting for a technical and an economic assessment. The liquid-lead jet spray is preferred to all other types because of its small space occupied and its simple design. It shall be used in near future in the HTR by the name of lead/helium HE. (GL) [de

  16. Warm Pressurant Gas Effects on the Liquid Hydrogen Bubble Point

    Science.gov (United States)

    Hartwig, Jason W.; McQuillen, John B.; Chato, David J.

    2013-01-01

    This paper presents experimental results for the liquid hydrogen bubble point tests using warm pressurant gases conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device. Three fine mesh screen samples (325 x 2300, 450 x 2750, 510 x 3600) were tested in liquid hydrogen using cold and warm noncondensible (gaseous helium) and condensable (gaseous hydrogen) pressurization schemes. Gases were conditioned from 0 to 90 K above the liquid temperature. Results clearly indicate a degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over noncondensible pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

  17. Automatic counting of fission fragments tracks using the gas permeation technique

    CERN Document Server

    Yamazaki, I M

    1999-01-01

    An automatic counting system for fission tracks induced in a polycarbonate plastic Makrofol KG (10 mu m thickness) is described. The method is based on the gas transport mechanism proposed by Knudsen, where the gas permeability for a porous membrane is expected to be directly related to its track density. In this work, nitrogen permeabilities for several Makrofol films, with different fission track densities, have been measured using an adequate gas permeation system. The fission tracks were produced by irradiating Makrofol foils with a 252Cf calibrated source in a 2 pi geometry. A calibration curve fission track number versus nitrogen permeability has been obtained, for track densities higher than 1000/cm sup 2 , where the spark gap technique and the visual methods employing a microscope, are not appropriate for track counting.

  18. Modelling of gas-liquid reactors - stability and dynamic behaviour of gas-liquid mass transfer accompanied by irreversible reaction

    NARCIS (Netherlands)

    Elk, E.P. van; Borman, P.C.; Kuipers, J.A.M.; Versteeg, G.F.

    1999-01-01

    The dynamic behaviour and stability of single-phase reacting systems has been investigated thoroughly in the past and design rules for stable operation are available from literature. The dynamic behaviour of gas-liquid processes is considerably more complex and has received relatively little

  19. Study of gas-liquid flow in model porous media for heterogeneous catalysis

    Science.gov (United States)

    Francois, Marie; Bodiguel, Hugues; Guillot, Pierre; Laboratory of the Future Team

    2015-11-01

    Heterogeneous catalysis of chemical reactions involving a gas and a liquid phase is usually achieved in fixed bed reactors. Four hydrodynamic regimes have been observed. They depend on the total flow rate and the ratio between liquid and gas flow rate. Flow properties in these regimes influence transfer rates. Rather few attempts to access local characterization have been proposed yet, though these seem to be necessary to better describe the physical mechanisms involved. In this work, we propose to mimic slices of reactor by using two-dimensional porous media. We have developed a two-dimensional system that is transparent to allow the direct observation of the flow and the phase distribution. While varying the total flow rate and the gas/liquid flow rate ratio, we observe two hydrodynamic regimes: at low flow rate, the gaseous phase is continuous (trickle flow), while it is discontinuous at higher flow rate (pulsed flow). Thanks to some image analysis techniques, we are able to quantify the local apparent liquid saturation in the system. Its fluctuations in time are characteristic of the transition between the two regimes: at low liquid flow rates, they are negligible since the liquid/gas interface is fixed, whereas at higher flow rates we observe an alternation between liquid and gas. This transition between trickle to pulsed flow is in relative good agreement with the existing state of art. However, we report in the pulsed regime important flow heterogeneities at the scale of a few pores. These heterogeneities are likely to have a strong influence on mass transfers. We acknowledge the support of Solvay.

  20. Ultrasonic Tomography Imaging for Liquid-Gas Flow Measurement

    Directory of Open Access Journals (Sweden)

    Muhammad Jaysuman PUSPPANATHAN

    2013-01-01

    Full Text Available This research was carried out to measure two-phase liquidgas flow regime by using a dual functionality ultrasonic transducer. Comparing to the common separated transmitter–receiver ultrasonic pairs transducer, the dual functionality ultrasonic transceiver is capable to produce the same measurable results hence further improvises and contributes to the hardware design improvement and system accuracy. Due to the disadvantages and the limitations of the separated ultrasonic transmitter–receiver pair, this paper presents a non-invasive ultrasonic tomography system using ultrasonic transceivers as an alternative approach. Implementation of ultrasonic transceivers, electronic measurement circuits, data acquisition system and suitable image reconstruction algorithms, the measurement of a liquid/gas flow was realized.

  1. Pump Propels Liquid And Gas Separately

    Science.gov (United States)

    Harvey, Andrew; Demler, Roger

    1993-01-01

    Design for pump that handles mixtures of liquid and gas efficiently. Containing only one rotor, pump is combination of centrifuge, pitot pump, and blower. Applications include turbomachinery in powerplants and superchargers in automobile engines. Efficiencies lower than those achieved in separate components. Nevertheless, design is practical and results in low consumption of power.

  2. Simulation of Water Level Fluctuations in a Hydraulic System Using a Coupled Liquid-Gas Model

    Directory of Open Access Journals (Sweden)

    Chao Wang

    2015-08-01

    Full Text Available A model for simulating vertical water level fluctuations with coupled liquid and gas phases is presented. The Preissmann implicit scheme is used to linearize the governing equations for one-dimensional transient flow for both liquid and gas phases, and the linear system is solved using the chasing method. Some classical cases for single liquid and gas phase transients in pipelines and networks are studied to verify that the proposed methods are accurate and reliable. The implicit scheme is extended using a dynamic mesh to simulate the water level fluctuations in a U-tube and an open surge tank without consideration of the gas phase. Methods of coupling liquid and gas phases are presented and used for studying the transient process and interaction between the phases, for gas phase limited in a chamber and gas phase transported in a pipeline. In particular, two other simplified models, one neglecting the effect of the gas phase on the liquid phase and the other one coupling the liquid and gas phases asynchronously, are proposed. The numerical results indicate that the asynchronous model performs better, and are finally applied to a hydropower station with surge tanks and air shafts to simulate the water level fluctuations and air speed.

  3. Magnetic resonance velocity imaging of liquid and gas two-phase flow in packed beds.

    Science.gov (United States)

    Sankey, M H; Holland, D J; Sederman, A J; Gladden, L F

    2009-02-01

    Single-phase liquid flow in porous media such as bead packs and model fixed bed reactors has been well studied by MRI. To some extent this early work represents the necessary preliminary research to address the more challenging problem of two-phase flow of gas and liquid within these systems. In this paper, we present images of both the gas and liquid velocities during stable liquid-gas flow of water and SF(6) within a packing of 5mm spheres contained within columns of diameter 40 and 27 mm; images being acquired using (1)H and (19)F observation for the water and SF(6), respectively. Liquid and gas flow rates calculated from the velocity images are in agreement with macroscopic flow rate measurements to within 7% and 5%, respectively. In addition to the information obtained directly from these images, the ability to measure liquid and gas flow fields within the same sample environment will enable us to explore the validity of assumptions used in numerical modelling of two-phase flows.

  4. Characterisation of Liquid Slugs in Gas-Liquid Taylor Flow in Microchannels

    Czech Academy of Sciences Publication Activity Database

    Záloha, Petr; Křišťál, Jiří; Jiřičný, Vladimír; Völkel, N.; Xuereb, C.; Aubin, J.

    2012-01-01

    Roč. 68, č. 1 (2012), s. 640-649 ISSN 0009-2509 Grant - others:IMPULSE(XE) NMP2-CT-2005-011816 Institutional research plan: CEZ:AV0Z40720504 Keywords : gas-liquid * micro-piv * microreactor Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.386, year: 2012

  5. Wetting in a colloidal liquid-gas system

    NARCIS (Netherlands)

    Wijting, W.K.; Besseling, N.A.M.; Cohen Stuart, M.A.

    2003-01-01

    We present first observations of wetting phenomena in depletion interaction driven, phase separated colloidal dispersions (coated silica-cyclohexane-polydimethylsiloxane). The contact angle of the colloidal liquid-gas interface at a solid substrate (coated glass) was determined for a series of

  6. Computation of liquid-liquid equilibria and phase stabilities: implications for RH-dependent gas/particle partitioning of organic-inorganic aerosols

    Directory of Open Access Journals (Sweden)

    A. Zuend

    2010-08-01

    Full Text Available Semivolatile organic and inorganic aerosol species partition between the gas and aerosol particle phases to maintain thermodynamic equilibrium. Liquid-liquid phase separation into an organic-rich and an aqueous electrolyte phase can occur in the aerosol as a result of the salting-out effect. Such liquid-liquid equilibria (LLE affect the gas/particle partitioning of the different semivolatile compounds and might significantly alter both particle mass and composition as compared to a one-phase particle. We present a new liquid-liquid equilibrium and gas/particle partitioning model, using as a basis the group-contribution model AIOMFAC (Zuend et al., 2008. This model allows the reliable computation of the liquid-liquid coexistence curve (binodal, corresponding tie-lines, the limit of stability/metastability (spinodal, and further thermodynamic properties of multicomponent systems. Calculations for ternary and multicomponent alcohol/polyol-water-salt mixtures suggest that LLE are a prevalent feature of organic-inorganic aerosol systems. A six-component polyol-water-ammonium sulphate system is used to simulate effects of relative humidity (RH and the presence of liquid-liquid phase separation on the gas/particle partitioning. RH, salt concentration, and hydrophilicity (water-solubility are identified as key features in defining the region of a miscibility gap and govern the extent to which compound partitioning is affected by changes in RH. The model predicts that liquid-liquid phase separation can lead to either an increase or decrease in total particulate mass, depending on the overall composition of a system and the particle water content, which is related to the hydrophilicity of the different organic and inorganic compounds. Neglecting non-ideality and liquid-liquid phase separations by assuming an ideal mixture leads to an overestimation of the total particulate mass by up to 30% for the composition and RH range considered in the six

  7. X-ray detector for automatic exposure control using ionization chamber filled with xenon gas

    CERN Document Server

    Nakagawa, A; Yoshida, T

    2003-01-01

    This report refers to our newly developed X-ray detector for reliable automatic X-ray exposure control, which is to be widely used for X-ray diagnoses in various clinical fields. This new detector utilizes an ionization chamber filled with xenon gas, in contrast to conventional X-ray detectors which use ionization chambers filled with air. Use of xenon gas ensures higher sensitivity and thinner design of the detector. The xenon gas is completely sealed in the chamber, so that the influence of the changes in ambient environments is minimized. (author)

  8. Method and system for purification of gas/liquid streams for fuel cells or electrolysis cells

    DEFF Research Database (Denmark)

    2013-01-01

    at least one scrubber in the gas/liquid stream at the inlet side of the first electrode of the fuel cell or electrolysis cell; and/or providing at least one scrubber in the gas/liquid stream at the inlet side of the second electrode of the fuel cell or electrolysis cell; and - purifying the gas....../liquid streams towards the first and second electrode; wherein the at least one scrubber in the gas/liquid stream at the inlet side of the first electrode and/or the at least one scrubber in the gas/liquid stream at the inlet side of the second electrode comprises a material suitable as an electrolyte material...... with the at least one scrubber, with the proviso that the fuel cell or electrolysis cell is not a solid oxide cell....

  9. Diffusivity measurements in some organic solvents by a gas-liquid diaphragm cell

    NARCIS (Netherlands)

    Littel, R.J.; Littel, R.J.; Versteeg, Geert; van Swaaij, Willibrordus Petrus Maria

    1992-01-01

    A diaphragm cell has been developed for the measurement of diffusion coefficients of gases In liquids. The diaphragm cell is operated batchwise with respect to both gas and liquid phases, and the diffusion process Is followed by means of the gas pressure decrease which is recorded by means of a

  10. Diffusivity Measurements in Some Organic Solvents by a Gas-Liquid Diaphragm Cell

    NARCIS (Netherlands)

    Littel, Rob J.; Versteeg, Geert F.; Swaaij, Wim P.M. van

    1992-01-01

    A diaphragm cell has been developed for the measurement of diffusion coefficients of gases in liquids. The diaphragm cell is operated batchwise with respect to both gas and liquid phases, and the diffusion process is followed by means of the gas pressure decrease which is recorded by means of a

  11. Study on cocurrent downtake gas-liquid flow in a vertical channel

    International Nuclear Information System (INIS)

    Lozovetskij, V.V.

    1978-01-01

    Hydraulic resistance and liquid stall from the film surface at cocurrent film and gas downflow in vertical channel in measurement range of reynolds number from 100 to 1260 for the film and from 1.2x10 4 to 10 5 for gas are studied. For downflow two regimes are characteristic: purely annular, that is separate phase flow regime, and the regime of stall and carrying liquid droplets from the film surface, that is annular dispersed flow regime. The existence boundaries of both regimes are determined and criterial equations for pressure drop calculation are obtained. It is established experimentally that at sufficient range from the liquid input place on the working zone the established two-phase flow takes place. In their nucleus two areas can be singled out, which differ by the flow density values of stalled liquid: central, having the permanent flow density value and area adjacent to the film surface, the liquid in the combs of waves making a significant contribution to the flow density value. At equal flooding density with the relative gas speed increase, the flow density value of stalled liquid in the channel central part increase. A similar result also takes place at flooding density increase at permanent relative speed. Flooding density and relative speed increase leads to levelling stalled liquid distribution about the channel cross section

  12. Data process of liquid scintillation counting

    International Nuclear Information System (INIS)

    Ishikawa, Hiroaki; Kuwajima, Susumu.

    1975-01-01

    The use of liquid scintillation counting system has been significantly spread because automatic sample changers and printers have recently come to be incorporated. However, the system will be systematized completely if automatic data processing and the sample preparation of radioactive materials to be measured are realized. Dry or wet oxidation method is applied to the sample preparation when radioactive materials are hard to dissolve into scintillator solution. Since these several years, the automatic sample combustion system, in which the dry oxidation is automated, has been rapidly spread and serves greatly to labor saving. Since the printers generally indicate only counted number, data processing system has been developed, and speeded up calculating process, which automatically corrects quenching of samples for obtaining the final radioactivity required. The data processing system is roughly divided into on-line and off-line systems according to whether computers are connected directly or indirectly, while its hardware is classified to input, calculating and output devices. Also, the calculation to determine sample activity by external standard method is explained. (Wakatsuki, Y.)

  13. Statistic characteristics of the gas-liquid flow in a vertical minichannel

    Science.gov (United States)

    Kozulin, I. A.; Kuznetsov, V. V.

    2010-03-01

    The gas-liquid upward flow was studied in a rectangular minichannel of 1.75×3.8 mm and length of 0.7 m. The experiments were carried out within the range of the gas superficial velocity from 0.1 to 10 m/s and the liquid superficial velocity from 0.07 to 0.7 m/s for the co-current H2O/CO2 flow under the conditions of saturation. The method for the two-beam laser scanning of structure and determination of statistic characteristics of the two-phase flow was worked through. The slug-bubble, slug, transitional, churn, and annular flows were distinguished. The statistics characteristics of liquid and gas phases motion in a minichannel were obtained for the first time including the velocities of phase motion.

  14. Analysing Gas-Liquid Flow in PEM Electrolyser Micro-Channels (Poster)

    DEFF Research Database (Denmark)

    Lafmejani, Saeed Sadeghi; Olesen, Anders Christian; Kær, Søren Knudsen

    One means of increasing the hydrogen yield to cost ratio of a PEM water electrolyser, is to increase the operating current density. However, at high current densities (higher than 1 A/cm2), management of heat and mass transfer in the anode current collector and channel becomes crucial and can lead...... to hot spots. Management of heat and fluid flow through the micro-channels play a great role in the capability of PEM water electrolysis when working at high current densities. Despite, many studies have been done on gas-liquid flows; still there is a lack of research on gas-liquid flows in micro......-sized channels (hydraulic diameter of 1 mm) of PEM water electrolysis. Precisely controlling all the parameters that affect the gas-liquid flow in a PEM water electrolysis cell is quite challenging, hence a simplified setup is constructed consisting of only a transparent channel with a sheet of titanium felt...

  15. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    International Nuclear Information System (INIS)

    Machado, Alessandra Carla Fattori Ergesse; Alves, Edenise Segala

    2007-01-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  16. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Alessandra Carla Fattori Ergesse [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Div. de Monitoracao Ambiental], E-mail: alessandra@ctmsp.mar.mil.br; Alves, Edenise Segala [Instituto de Botanica de Sao Paulo, SP (Brazil). Secao de Anatomia], E-mail: ealves@ibot.sp.gov.br

    2007-07-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  17. Composite hollow fiber gas-liquid membrane contactors for olefin/paraffin separation

    NARCIS (Netherlands)

    Nijmeijer, Dorothea C.; Visser, Tymen; Assen, R.; Wessling, Matthias

    2004-01-01

    Gas¿liquid membrane contactors frequently suffer from undesired wetting of the microporous membrane by the absorption liquid. Stabilization layers at the liquid-side of the microporous membrane potentially prevent this wetting. We apply such stabilized membranes in a membrane contactor using AgNO3

  18. Determination of Organic Pollutants in Small Samples of Groundwaters by Liquid-Liquid Extraction and Capillary Gas Chromatography

    DEFF Research Database (Denmark)

    Harrison, I.; Leader, R.U.; Higgo, J.J.W.

    1994-01-01

    A method is presented for the determination of 22 organic compounds in polluted groundwaters. The method includes liquid-liquid extraction of the base/neutral organics from small, alkaline groundwater samples, followed by derivatisation and liquid-liquid extraction of phenolic compounds after neu...... neutralisation. The extracts were analysed by capillary gas chromatography. Dual detection by flame Ionisation and electron capture was used to reduce analysis time....

  19. High pressure gas driven liquid metal MHD homopolar generator

    International Nuclear Information System (INIS)

    Itoh, Yasuyuki

    1988-01-01

    A liquid metal MHD homopolar generator is proposed to be used as a high repetition rate pulsed power supply. In the generator, the thermal energy stored in a high pressure gas (He) reservoir is rapidly converted into kinetic energy of a rotating liquid metal (NaK) cylinder which is contracted by a gas driven annular free piston. The rotational kinetic energy is converted into electrical energy by making use of the homopolar generator principle. The conversion efficiency is calculated to be 47% in generating electrical energy of 20 kJ/pulse (1.7 MW peak power) at a repetition rate of 7 Hz. From the viewpoint of energy storage, the high pressure gas reservoir with a charging pressure of 15 MPa is considered to ''electrically'' store the energy at a density of 10 MJ/m 3 . (author)

  20. Gas and liquid sampling for closed canisters in KW Basin - Work Plan

    International Nuclear Information System (INIS)

    Pitkoff, C.C.

    1995-01-01

    Work Plan for the design and fabrication of gas/liquid sampler for closed canister sampling in KW Basin. This document defines the tasks associated with the design, fabrication, assembly, and acceptance testing equipment necessary for gas and liquid sampling of the Mark I and Mark II canisters in the K-West basin. The sampling of the gas space and the remaining liquid inside the closed canisters will be used to help understand any changes to the fuel elements and the canisters. Specifically, this work plan will define the scope of work and required task structure, list the technical requirements, describe design configuration control and verification methodologies, detail quality assurance requirements, and present a baseline estimate and schedule

  1. Bubble-induced mixing of two horizontal liquid layers with non-uniform gas injection at the bottom

    International Nuclear Information System (INIS)

    Cheung, F.B.; Pedersen, D.R.; Leinweber, G.

    1986-01-01

    During a postulated severe core meltdown accident in an LMFBR, a large amount of sodium coolant may spill into the reactor concrete cavity. A layer of liquid products may form as a result of the sodium-concrete reactions. The liquid product layer, which is highly viscous and much heavier than sodium, separates the concrete from the sodium pool. In general, the downward transport of sodium through the liquid product layer to the unreacted concrete surface, which controls the rate of chemical erosion of the concrete, depends strongly on the agitation induced by gas evolution from the heated concrete. In this study, experiments were conducted to explore the effect of non-uniform gas injection on mixing of two horizontal mutually soluble liquid layers. The liquid in the lower layer was chosen to be more viscous and heavier than the liquid in the upper layer. To simulate the reactor accident situation, gas was injected at the bottom of the liquid-liquid system through a circular hole that covered only the center portion of the bottom surface of the lower liquid layer. The bubble-induced mixing motions were observed and the rate of mixing was measured for different hole sizes and various gas flow rates. The results of this study clearly show that the rate of gas injection is not the only parameter controlling the mixing of the liquid-liquid system. The effect of non-uniform gas injection is important at high gas flow rates. Within the present experimental conditions, the reduction in the overall mixing rate can be as large as a factor of three

  2. Prediction of gas volume fraction in fully-developed gas-liquid flow in a vertical pipe

    International Nuclear Information System (INIS)

    Islam, A.S.M.A.; Adoo, N.A.; Bergstrom, D.J.; Wang, D.F.

    2015-01-01

    An Eulerian-Eulerian two-fluid model has been implemented for the prediction of the gas volume fraction profile in turbulent upward gas-liquid flow in a vertical pipe. The two-fluid transport equations are discretized using the finite volume method and a low Reynolds number κ-ε turbulence model is used to predict the turbulence field for the liquid phase. The contribution to the effective turbulence by the gas phase is modeled by a bubble induced turbulent viscosity. For the fully-developed flow being considered, the gas volume fraction profile is calculated using the radial momentum balance for the bubble phase. The model potentially includes the effect of bubble size on the interphase forces and turbulence model. The results obtained are in good agreement with experimental data from the literature. The one-dimensional formulation being developed allows for the efficient assessment and further development of both turbulence and two-fluid models for multiphase flow applications in the nuclear industry. (author)

  3. Prediction of gas volume fraction in fully-developed gas-liquid flow in a vertical pipe

    Energy Technology Data Exchange (ETDEWEB)

    Islam, A.S.M.A.; Adoo, N.A.; Bergstrom, D.J., E-mail: nana.adoo@usask.ca [University of Saskatchewan, Department of Mechanical Engineering, Saskatoon, SK (Canada); Wang, D.F. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    An Eulerian-Eulerian two-fluid model has been implemented for the prediction of the gas volume fraction profile in turbulent upward gas-liquid flow in a vertical pipe. The two-fluid transport equations are discretized using the finite volume method and a low Reynolds number κ-ε turbulence model is used to predict the turbulence field for the liquid phase. The contribution to the effective turbulence by the gas phase is modeled by a bubble induced turbulent viscosity. For the fully-developed flow being considered, the gas volume fraction profile is calculated using the radial momentum balance for the bubble phase. The model potentially includes the effect of bubble size on the interphase forces and turbulence model. The results obtained are in good agreement with experimental data from the literature. The one-dimensional formulation being developed allows for the efficient assessment and further development of both turbulence and two-fluid models for multiphase flow applications in the nuclear industry. (author)

  4. Photodynamic therapy using upconversion nanoparticles prepared by laser ablation in liquid

    Energy Technology Data Exchange (ETDEWEB)

    Ikehata, Tomohiro; Onodera, Yuji; Nunokawa, Takashi [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8502 (Japan); Hirano, Tomohisa; Ogura, Shun-ichiro; Kamachi, Toshiaki [Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8502 (Japan); Odawara, Osamu [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8502 (Japan); Wada, Hiroyuki, E-mail: wada.h.ac@m.titech.ac.jp [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8502 (Japan)

    2015-09-01

    Highlights: • Highly crystalline upconversion nanoparticles were prepared by laser ablation in liquid. • Highly transparent near-IR irradiation generated singlet oxygen. • Viability of cancer cells was significantly decreased by near-IR irradiation. - Abstract: Upconversion nanoparticles were prepared by laser ablation in liquid, and the potential use of the nanoparticles for cancer treatment was investigated. A Nd:YAG/SHG laser (532 nm, 13 ns, 10 Hz) was used for ablation, and the cancer treatment studied was photodynamic therapy (PDT). Morphology and crystallinity of prepared nanoparticles were examined by transmission electron microscopy and X-ray diffraction. Red and green emissions resulting from near-infrared excitation were observed by a fluorescence spectrophotometer. Generation of singlet oxygen was confirmed by a photochemical method using 1,3-diphenylisobenzofuran (DPBF). In vitro experiments using cultivated cancer cells were conducted to investigate PDT effects. Uptake of the photosensitizer by cancer cells and cytotoxicities of cancer cells were also examined. We conclude that the combination of PDT and highly crystalline nanoparticles, which were prepared by laser ablation in liquid, is an effective cancer treatment.

  5. Gas hydrate inhibition by perturbation of liquid water structure

    Science.gov (United States)

    Sa, Jeong-Hoon; Kwak, Gye-Hoon; Han, Kunwoo; Ahn, Docheon; Lee, Kun-Hong

    2015-06-01

    Natural gas hydrates are icy crystalline materials that contain hydrocarbons, which are the primary energy source for this civilization. The abundance of naturally occurring gas hydrates leads to a growing interest in exploitation. Despite their potential as energy resources and in industrial applications, there is insufficient understanding of hydrate kinetics, which hinders the utilization of these invaluable resources. Perturbation of liquid water structure by solutes has been proposed to be a key process in hydrate inhibition, but this hypothesis remains unproven. Here, we report the direct observation of the perturbation of the liquid water structure induced by amino acids using polarized Raman spectroscopy, and its influence on gas hydrate nucleation and growth kinetics. Amino acids with hydrophilic and/or electrically charged side chains disrupted the water structure and thus provided effective hydrate inhibition. The strong correlation between the extent of perturbation by amino acids and their inhibition performance constitutes convincing evidence for the perturbation inhibition mechanism. The present findings bring the practical applications of gas hydrates significantly closer, and provide a new perspective on the freezing and melting phenomena of naturally occurring gas hydrates.

  6. Liquid scintillation: Sample preparation and counting atypical emissions

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Liquid scintillation sample preparation has the most published information but the least amount of definitive technical direction because the chemical and physical nature of the samples from biological investigations varies widely. This chapter discusses the following related topics: Aqueous Samples; Tissue Solubilizers; Absorption of 14 CO 2 ; Sample Combustion Methods; Heterogeneous Systems; Sample Preparation Problems (colored samples, chemiluminescence, photoluminescence, static electricity); Counting Various Types of Emitters; Counting Atypical Emissions. 2 refs., 2 figs

  7. All-soft, battery-free, and wireless chemical sensing platform based on liquid metal for liquid- and gas-phase VOC detection.

    Science.gov (United States)

    Kim, Min-Gu; Alrowais, Hommood; Kim, Choongsoon; Yeon, Pyungwoo; Ghovanloo, Maysam; Brand, Oliver

    2017-06-27

    Lightweight, flexible, stretchable, and wireless sensing platforms have gained significant attention for personal healthcare and environmental monitoring applications. This paper introduces an all-soft (flexible and stretchable), battery-free, and wireless chemical microsystem using gallium-based liquid metal (eutectic gallium-indium alloy, EGaIn) and poly(dimethylsiloxane) (PDMS), fabricated using an advanced liquid metal thin-line patterning technique based on soft lithography. Considering its flexible, stretchable, and lightweight characteristics, the proposed sensing platform is well suited for wearable sensing applications either on the skin or on clothing. Using the microfluidic sensing platform, detection of liquid-phase and gas-phase volatile organic compounds (VOC) is demonstrated using the same design, which gives an opportunity to have the sensor operate under different working conditions and environments. In the case of liquid-phase chemical sensing, the wireless sensing performance and microfluidic capacitance tunability for different dielectric liquids are evaluated using analytical, numerical, and experimental approaches. In the case of gas-phase chemical sensing, PDMS is used both as a substrate and a sensing material. The gas sensing performance is evaluated and compared to a silicon-based, solid-state gas sensor with a PDMS sensing film.

  8. Measurement of pressure fluctuation in gas-liquid two-phase vortex street

    International Nuclear Information System (INIS)

    Sun Zhiqiang; Sang Wenhui; Zhang Hongjian

    2009-01-01

    The pressure fluctuation in the wake is an important parameter to characterize the shedding process of gas-liquid two-phase Karman vortex street. This paper investigated such pressure fluctuations in a horizontal pipe using air and water as the tested fluid media. The dynamic signal representing the pressure fluctuation was acquired by the duct-wall differential pressure method. Results show that in the wake of the gas-liquid two-phase Karman vortex street, the frequency of the pressure fluctuation is linear with the Reynolds number when the volume void fraction is within the range of 18%. Moreover, the mean amplitude of the pressure fluctuation decreases with the volume void fraction, and the mean amplitude is larger at higher water flowrates under the same volume void fraction. These findings contribute to an in-depth understanding of the gas-liquid two-phase Karman vortex street.

  9. Phase diagram and universality of the Lennard-Jones gas-liquid system

    KAUST Repository

    Watanabe, Hiroshi

    2012-01-01

    The gas-liquid phase transition of the three-dimensional Lennard-Jones particles system is studied by molecular dynamics simulations. The gas and liquid densities in the coexisting state are determined with high accuracy. The critical point is determined by the block density analysis of the Binder parameter with the aid of the law of rectilinear diameter. From the critical behavior of the gas-liquid coexisting density, the critical exponent of the order parameter is estimated to be β = 0.3285(7). Surface tension is estimated from interface broadening behavior due to capillary waves. From the critical behavior of the surface tension, the critical exponent of the correlation length is estimated to be ν = 0.63(4). The obtained values of β and ν are consistent with those of the Ising universality class. © 2012 American Institute of Physics.

  10. Automatic liquid handling for life science: a critical review of the current state of the art.

    Science.gov (United States)

    Kong, Fanwei; Yuan, Liang; Zheng, Yuan F; Chen, Weidong

    2012-06-01

    Liquid handling plays a pivotal role in life science laboratories. In experiments such as gene sequencing, protein crystallization, antibody testing, and drug screening, liquid biosamples frequently must be transferred between containers of varying sizes and/or dispensed onto substrates of varying types. The sample volumes are usually small, at the micro- or nanoliter level, and the number of transferred samples can be huge when investigating large-scope combinatorial conditions. Under these conditions, liquid handling by hand is tedious, time-consuming, and impractical. Consequently, there is a strong demand for automated liquid-handling methods such as sensor-integrated robotic systems. In this article, we survey the current state of the art in automatic liquid handling, including technologies developed by both industry and research institutions. We focus on methods for dealing with small volumes at high throughput and point out challenges for future advancements.

  11. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Interfacial transport characteristics in a gas-liquid or an immiscible liquid-liquid stratified flow

    International Nuclear Information System (INIS)

    Inoue, A.; Aoki, S.; Aritomi, M.; Kozawa, Y.

    1982-01-01

    This paper is a review for an interfacial transport characteristics of mass, momentum and energy in a gas-liquid or a immiscible liquid-liquid stratified flow with wavy interface which have been studied in our division. In the experiment, a characteristic of wave motion and its effect to the turbulence near the interface as well as overall flow characteristics like pressure drop, position of the interface were investigated in an air-water, an air-mercury and a water-liquid metal stratified flow. On the other hand, several models based on the mixing length model and a two-equation model of turbulence, with special interfacial boundary conditions in which the wavy surface was regarded as a rough surface correspond to the wavy height, a source of turbulent energy equal to the wave energy and a damped-turbulence due to the surface tension, were proposed to predict the flow characteristics and the interfacial heat transfer in a fully developed and an undeveloped stratified flow and examined by the experimental data. (author)

  13. Ionic liquids: solvents and sorbents in sample preparation.

    Science.gov (United States)

    Clark, Kevin D; Emaus, Miranda N; Varona, Marcelino; Bowers, Ashley N; Anderson, Jared L

    2018-01-01

    The applications of ionic liquids (ILs) and IL-derived sorbents are rapidly expanding. By careful selection of the cation and anion components, the physicochemical properties of ILs can be altered to meet the requirements of specific applications. Reports of IL solvents possessing high selectivity for specific analytes are numerous and continue to motivate the development of new IL-based sample preparation methods that are faster, more selective, and environmentally benign compared to conventional organic solvents. The advantages of ILs have also been exploited in solid/polymer formats in which ordinarily nonspecific sorbents are functionalized with IL moieties in order to impart selectivity for an analyte or analyte class. Furthermore, new ILs that incorporate a paramagnetic component into the IL structure, known as magnetic ionic liquids (MILs), have emerged as useful solvents for bioanalytical applications. In this rapidly changing field, this Review focuses on the applications of ILs and IL-based sorbents in sample preparation with a special emphasis on liquid phase extraction techniques using ILs and MILs, IL-based solid-phase extraction, ILs in mass spectrometry, and biological applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Super liquid-repellent gas membranes for carbon dioxide capture and heart-lung machines.

    Science.gov (United States)

    Paven, Maxime; Papadopoulos, Periklis; Schöttler, Susanne; Deng, Xu; Mailänder, Volker; Vollmer, Doris; Butt, Hans-Jürgen

    2013-01-01

    In a gas membrane, gas is transferred between a liquid and a gas through a microporous membrane. The main challenge is to achieve a high gas transfer while preventing wetting and clogging. With respect to the oxygenation of blood, haemocompatibility is also required. Here we coat macroporous meshes with a superamphiphobic-or liquid repellent-layer to meet this challenge. The superamphiphobic layer consists of a fractal-like network of fluorinated silicon oxide nanospheres; gas trapped between the nanospheres keeps the liquid from contacting the wall of the membrane. We demonstrate the capabilities of the membrane by capturing carbon dioxide gas into a basic aqueous solution and in addition use it to oxygenate blood. Usually, blood tends to clog membranes because of the abundance of blood cells, platelets, proteins and lipids. We show that human blood stored in a superamphiphobic well for 24 h can be poured off without leaving cells or adsorbed protein behind.

  15. Flow-pattern identification and nonlinear dynamics of gas-liquid two-phase flow in complex networks.

    Science.gov (United States)

    Gao, Zhongke; Jin, Ningde

    2009-06-01

    The identification of flow pattern is a basic and important issue in multiphase systems. Because of the complexity of phase interaction in gas-liquid two-phase flow, it is difficult to discern its flow pattern objectively. In this paper, we make a systematic study on the vertical upward gas-liquid two-phase flow using complex network. Three unique network construction methods are proposed to build three types of networks, i.e., flow pattern complex network (FPCN), fluid dynamic complex network (FDCN), and fluid structure complex network (FSCN). Through detecting the community structure of FPCN by the community-detection algorithm based on K -mean clustering, useful and interesting results are found which can be used for identifying five vertical upward gas-liquid two-phase flow patterns. To investigate the dynamic characteristics of gas-liquid two-phase flow, we construct 50 FDCNs under different flow conditions, and find that the power-law exponent and the network information entropy, which are sensitive to the flow pattern transition, can both characterize the nonlinear dynamics of gas-liquid two-phase flow. Furthermore, we construct FSCN and demonstrate how network statistic can be used to reveal the fluid structure of gas-liquid two-phase flow. In this paper, from a different perspective, we not only introduce complex network theory to the study of gas-liquid two-phase flow but also indicate that complex network may be a powerful tool for exploring nonlinear time series in practice.

  16. Modeling the gas-particle partitioning of secondary organic aerosol: the importance of liquid-liquid phase separation

    Directory of Open Access Journals (Sweden)

    A. Zuend

    2012-05-01

    Full Text Available The partitioning of semivolatile organic compounds between the gas phase and aerosol particles is an important source of secondary organic aerosol (SOA. Gas-particle partitioning of organic and inorganic species is influenced by the physical state and water content of aerosols, and therefore ambient relative humidity (RH, as well as temperature and organic loading levels. We introduce a novel combination of the thermodynamic models AIOMFAC (for liquid mixture non-ideality and EVAPORATION (for pure compound vapor pressures with oxidation product information from the Master Chemical Mechanism (MCM for the computation of gas-particle partitioning of organic compounds and water. The presence and impact of a liquid-liquid phase separation in the condensed phase is calculated as a function of variations in relative humidity, organic loading levels, and associated changes in aerosol composition. We show that a complex system of water, ammonium sulfate, and SOA from the ozonolysis of α-pinene exhibits liquid-liquid phase separation over a wide range of relative humidities (simulated from 30% to 99% RH. Since fully coupled phase separation and gas-particle partitioning calculations are computationally expensive, several simplified model approaches are tested with regard to computational costs and accuracy of predictions compared to the benchmark calculation. It is shown that forcing a liquid one-phase aerosol with or without consideration of non-ideal mixing bears the potential for vastly incorrect partitioning predictions. Assuming an ideal mixture leads to substantial overestimation of the particulate organic mass, by more than 100% at RH values of 80% and by more than 200% at RH values of 95%. Moreover, the simplified one-phase cases stress two key points for accurate gas-particle partitioning calculations: (1 non-ideality in the condensed phase needs to be considered and (2 liquid-liquid phase separation is a consequence of considerable deviations

  17. Gas Separation Ability of the Liquid Bubble Film.

    Czech Academy of Sciences Publication Activity Database

    Řezníčková Čermáková, Jiřina; Petričkovič, Roman; Vejražka, Jiří; Setničková, Kateřina; Uchytil, Petr

    2016-01-01

    Roč. 166, JUN 22 (2016), s. 26-33 ISSN 1383-5866 Institutional support: RVO:67985858 Keywords : liquid film membrane * bubble * gas separation Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.359, year: 2016

  18. (Vapour + liquid) equilibria of ternary systems with ionic liquids using headspace gas chromatography

    International Nuclear Information System (INIS)

    Mokhtarani, Babak; Gmehling, Juergen

    2010-01-01

    (Vapour + liquid) equilibrium (VLE) data for the ternary systems (hexane + benzene), (hexane + cyclohexane), (benzene + cyclohexane), and (ethanol + water) with an ionic liquid as entrainer for extractive distillation were measured by headspace gas chromatography. As ionic liquids, 1-hexyl-3-methyl-imidazolium bis (trifluoromethyl-sulfonyl) imide [HMIM][BTI], 1-octyl-3-methyl-imidazolium bis (trifluoromethyl-sulfonyl) imide [OMIM][BTI], 1-octyl-3-methyl-imidazolium trifluoro-methanesulfonate [OMIM][OTF], and 1-butyl-3-methyl-imidazolium trifluoro-methanesulfonate [BMIM][OTF] were used. The experimental data show that the ionic liquids investigated have a great influence on the separation factors of the systems (hexane + benzene), (hexane + cyclohexane), and (benzene + cyclohexane). The experimental data were compared with the predicted results using mod. UNIFAC (Do). The predicted results are in good agreement with the experimental data.

  19. (Vapour + liquid) equilibria of ternary systems with ionic liquids using headspace gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Mokhtarani, Babak [Chemistry and Chemical Engineering Research Center of Iran, P.O. Box 14335-186, Tehran (Iran, Islamic Republic of); Gmehling, Juergen, E-mail: gmehling@tech.chem.uni-oldenburg.d [Carl von Ossietzky Universitaet Oldenburg, Technische Chemie, D-26111 Oldenburg (Germany)

    2010-08-15

    (Vapour + liquid) equilibrium (VLE) data for the ternary systems (hexane + benzene), (hexane + cyclohexane), (benzene + cyclohexane), and (ethanol + water) with an ionic liquid as entrainer for extractive distillation were measured by headspace gas chromatography. As ionic liquids, 1-hexyl-3-methyl-imidazolium bis (trifluoromethyl-sulfonyl) imide [HMIM][BTI], 1-octyl-3-methyl-imidazolium bis (trifluoromethyl-sulfonyl) imide [OMIM][BTI], 1-octyl-3-methyl-imidazolium trifluoro-methanesulfonate [OMIM][OTF], and 1-butyl-3-methyl-imidazolium trifluoro-methanesulfonate [BMIM][OTF] were used. The experimental data show that the ionic liquids investigated have a great influence on the separation factors of the systems (hexane + benzene), (hexane + cyclohexane), and (benzene + cyclohexane). The experimental data were compared with the predicted results using mod. UNIFAC (Do). The predicted results are in good agreement with the experimental data.

  20. The effect of surfactant on stratified and stratifying gas-liquid flows

    Science.gov (United States)

    Heiles, Baptiste; Zadrazil, Ivan; Matar, Omar

    2013-11-01

    We consider the dynamics of a stratified/stratifying gas-liquid flow in horizontal tubes. This flow regime is characterised by the thin liquid films that drain under gravity along the pipe interior, forming a pool at the bottom of the tube, and the formation of large-amplitude waves at the gas-liquid interface. This regime is also accompanied by the detachment of droplets from the interface and their entrainment into the gas phase. We carry out an experimental study involving axial- and radial-view photography of the flow, in the presence and absence of surfactant. We show that the effect of surfactant is to reduce significantly the average diameter of the entrained droplets, through a tip-streaming mechanism. We also highlight the influence of surfactant on the characteristics of the interfacial waves, and the pressure gradient that drives the flow. EPSRC Programme Grant EP/K003976/1.

  1. BORILAIN. Mobile device for automatic continuous supply of liquid injection system backup of a nuclear plant in emergency; BORILAIN. Dispositivo movil para el abastecimiento automatico en continuo del sistema de inyeccion del liquido de reserva de una central nuclear en situacion de emergencia

    Energy Technology Data Exchange (ETDEWEB)

    Lacalle, J.; Traino, J.; Troeung, J.; Arnaldos, A.; Alcaraz, D. A.; Lopez, B.; Ponce, A. T.

    2014-07-01

    This paper presents the design and development of the first automatic mobile device for the preparation of a neutron absorbing solution, and providing continuous, 30 days, of the injection system liquid reserve of a nuclear emergency. The work has been developed by GD Energy Services (GDES) for Electricite de France (EDF). (Author)

  2. Parallelization of simulation code for liquid-gas model of lattice-gas fluid

    International Nuclear Information System (INIS)

    Kawai, Wataru; Ebihara, Kenichi; Kume, Etsuo; Watanabe, Tadashi

    2000-03-01

    A simulation code for hydrodynamical phenomena which is based on the liquid-gas model of lattice-gas fluid is parallelized by using MPI (Message Passing Interface) library. The parallelized code can be applied to the larger size of the simulations than the non-parallelized code. The calculation times of the parallelized code on VPP500 (Vector-Parallel super computer with dispersed memory units), AP3000 (Scalar-parallel server with dispersed memory units), and a workstation cluster decreased in inverse proportion to the number of processors. (author)

  3. Gas-to-liquids : who cares?

    International Nuclear Information System (INIS)

    Yakobson, D.L.

    1999-01-01

    An overview of gas-to-liquids (GTL) technology was presented along with its capital costs, economics and market niche. GTL technology is a process developed by Fischer-Tropsch in the 1920s, in which carbonaceous feedstock is catalytically converted into synthetic oil. The feedstock can be natural gas, coal, or refinery bottoms, bitumen, Orimulsion TM or biomass. The process involves the making of a gaseous mixture of hydrogen and carbon monoxide and then feeding that mixture into a reactor containing a catalyst. The last step involves the processing of the synthetic oil into fractions for sale. The issue of whether GTL will compete with refinery production or supplement it was also raised. The potential for GTL projects in North America were reviewed. The five companies which have matured GTL technologies are Exxon, Rentech, Sasol, Shell and Syntroleum

  4. Gas-Liquid Precipitation of water dissolved heavy metal ions using hydrogen sulfide gas

    NARCIS (Netherlands)

    Al Tarazi, M.Y.M.

    2004-01-01

    Precipitation of solids promoted by gas-liquid reactions is applied in many industrial processes such as the production of ammonium phosphate, ammonium sulphate, barium carbonate, calcium carbonate, calcium fluoride, ypsum (calcium sulphate), goethite, sodium bicarbonate, strontium carbonate and

  5. Liquid chromatography-mass spectrometry platform for both small neurotransmitters and neuropeptides in blood, with automatic and robust solid phase extraction

    Science.gov (United States)

    Johnsen, Elin; Leknes, Siri; Wilson, Steven Ray; Lundanes, Elsa

    2015-03-01

    Neurons communicate via chemical signals called neurotransmitters (NTs). The numerous identified NTs can have very different physiochemical properties (solubility, charge, size etc.), so quantification of the various NT classes traditionally requires several analytical platforms/methodologies. We here report that a diverse range of NTs, e.g. peptides oxytocin and vasopressin, monoamines adrenaline and serotonin, and amino acid GABA, can be simultaneously identified/measured in small samples, using an analytical platform based on liquid chromatography and high-resolution mass spectrometry (LC-MS). The automated platform is cost-efficient as manual sample preparation steps and one-time-use equipment are kept to a minimum. Zwitter-ionic HILIC stationary phases were used for both on-line solid phase extraction (SPE) and liquid chromatography (capillary format, cLC). This approach enabled compounds from all NT classes to elute in small volumes producing sharp and symmetric signals, and allowing precise quantifications of small samples, demonstrated with whole blood (100 microliters per sample). An additional robustness-enhancing feature is automatic filtration/filter back-flushing (AFFL), allowing hundreds of samples to be analyzed without any parts needing replacement. The platform can be installed by simple modification of a conventional LC-MS system.

  6. Gas–liquid flow in stirred reactors: Trailing vortices and gas accumulation behind impeller blades

    NARCIS (Netherlands)

    Ranade, V.; Deshpande, Vaibhav R.

    1999-01-01

    In a gas–liquid stirred reactor, gas tends to accumulate in low-pressure regions behind the impeller blades. Such gas accumulation significantly alters impeller performance characteristics. We have computationally investigated gas–liquid flow generated by a Rushton (disc) turbine. Rotating Rushton

  7. Convection Study by PIV Method Within Horizontal Liquid Layer Evaporating Into Inert Gas Flow

    Directory of Open Access Journals (Sweden)

    Kreta Aleksei

    2016-01-01

    Full Text Available The paper is devoted to the experimental study of convection in a horizontal evaporating liquid layer (ethanol of limited size under the action of gas flow (air. The two-dimensional velocity field in the liquid layer is obtained using the PIV method. The existence of a vortex convective flow within a liquid layer directed towards the gas flow has been revealed.

  8. Liquid gating elastomeric porous system with dynamically controllable gas/liquid transport.

    Science.gov (United States)

    Sheng, Zhizhi; Wang, Honglong; Tang, Yongliang; Wang, Miao; Huang, Lizhi; Min, Lingli; Meng, Haiqiang; Chen, Songyue; Jiang, Lei; Hou, Xu

    2018-02-01

    The development of membrane technology is central to fields ranging from resource harvesting to medicine, but the existing designs are unable to handle the complex sorting of multiphase substances required for many systems. Especially, the dynamic multiphase transport and separation under a steady-state applied pressure have great benefits for membrane science, but have not been realized at present. Moreover, the incorporation of precisely dynamic control with avoidance of contamination of membranes remains elusive. We show a versatile strategy for creating elastomeric microporous membrane-based systems that can finely control and dynamically modulate the sorting of a wide range of gases and liquids under a steady-state applied pressure, nearly eliminate fouling, and can be easily applied over many size scales, pressures, and environments. Experiments and theoretical calculation demonstrate the stability of our system and the tunability of the critical pressure. Dynamic transport of gas and liquid can be achieved through our gating interfacial design and the controllable pores' deformation without changing the applied pressure. Therefore, we believe that this system will bring new opportunities for many applications, such as gas-involved chemical reactions, fuel cells, multiphase separation, multiphase flow, multiphase microreactors, colloidal particle synthesis, and sizing nano/microparticles.

  9. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  10. Applications of liquid-phase microextraction in the sample preparation of environmental solid samples.

    Science.gov (United States)

    Prosen, Helena

    2014-05-23

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several innovative liquid-phase microextraction (LPME) techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME). Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  11. Hydrodynamic boundary conditions for one-component liquid-gas flows on non-isothermal solid substrates

    KAUST Repository

    Xu, Xinpeng; Liu, Chun; Qian, Tiezheng

    2012-01-01

    profiles of liquid-gas flows on non-isothermal, heterogeneous solid substrates is still absent. The purpose of this work is to construct a continuum model for simulating the liquid-gas flows on solid surfaces that are flat and rigid, and may involve

  12. Advancing liquid/liquid extraction through a novel microfluidic device: Theory, instrumentation and applications in gas chromatography

    NARCIS (Netherlands)

    Peroni, D.; van Egmond, W.; Kok, W.T.; Janssen, J.G.M.

    2012-01-01

    A new chip-based liquid-liquid extraction technique for sample preparation of aqueous samples for GC was developed. Extraction is performed in a segmented flow system with additional mixing provided by an etched channel structure. The dimensions of the device are optimized to allow benefiting of the

  13. Wetting in a Colloidal Liquid-Gas System

    Science.gov (United States)

    Wijting, W. K.; Besseling, N. A.; Stuart, M. A.

    2003-05-01

    We present first observations of wetting phenomena in depletion interaction driven, phase separated colloidal dispersions (coated silica cyclohexane-polydimethylsiloxane). The contact angle of the colloidal liquid-gas interface at a solid substrate (coated glass) was determined for a series of compositions. Upon approach to the critical point, a transition occurs from partial to complete wetting.

  14. Wetting in a colloidal liquid-gas system

    OpenAIRE

    Wijting, W.K.; Besseling, N.A.M.; Cohen Stuart, M.A.

    2003-01-01

    We present first observations of wetting phenomena in depletion interaction driven, phase separated colloidal dispersions (coated silica-cyclohexane-polydimethylsiloxane). The contact angle of the colloidal liquid-gas interface at a solid substrate (coated glass) was determined for a series of compositions. Upon approach to the critical point, a transition occurs from partial to complete wetting.

  15. In Situ Environmental TEM in Imaging Gas and Liquid Phase Chemical Reactions for Materials Research.

    Science.gov (United States)

    Wu, Jianbo; Shan, Hao; Chen, Wenlong; Gu, Xin; Tao, Peng; Song, Chengyi; Shang, Wen; Deng, Tao

    2016-11-01

    Gas and liquid phase chemical reactions cover a broad range of research areas in materials science and engineering, including the synthesis of nanomaterials and application of nanomaterials, for example, in the areas of sensing, energy storage and conversion, catalysis, and bio-related applications. Environmental transmission electron microscopy (ETEM) provides a unique opportunity for monitoring gas and liquid phase reactions because it enables the observation of those reactions at the ultra-high spatial resolution, which is not achievable through other techniques. Here, the fundamental science and technology developments of gas and liquid phase TEM that facilitate the mechanistic study of the gas and liquid phase chemical reactions are discussed. Combined with other characterization tools integrated in TEM, unprecedented material behaviors and reaction mechanisms are observed through the use of the in situ gas and liquid phase TEM. These observations and also the recent applications in this emerging area are described. The current challenges in the imaging process are also discussed, including the imaging speed, imaging resolution, and data management. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Liquid metal-to-gas leak-detection instruments

    International Nuclear Information System (INIS)

    Matlin, E.; Witherspoon, J.E.; Johnson, J.L.

    1982-01-01

    It is desirable for liquid-metal-cooled reactors that small liquid metal-to-gas leaks be reliably detected. Testing has been performed on a number of detection systems to evaluate their sensitivity, response time, and performance characteristics. This testing has been scheduled in three phases. The first phase was aimed at screening out the least suitable detectors and optimizing the performance of the most promising. In the second phase, candidates were tested in a 1500 ft 3 walk-in type enclosure in which leaks were simulated on 24-in. and 3-in. piping. In the third phase of testing, selected type detectors were tested in the 1500-ft 3 enclosure with Clinch River Breeder Reactor Plant (CRBRP) pipe insulation configurations and detector tubing configuration with cell gas recirculation simulated. Endurance testing of detection equipment was also performed as part of this effort. Test results have been shown that aerosol-type detectors will reliably detect leaks as small as a few grams per hour when sampling pipe insulation annuli

  17. Transient effects caused by pulsed gas and liquid injections into low pressure plasmas

    International Nuclear Information System (INIS)

    Ogawa, D; Goeckner, M; Overzet, L; Chung, C W

    2010-01-01

    The fast injection of liquid droplets into a glow discharge causes significant time variations in the pressure, the chemical composition of the gas and the phases present (liquid and/or solid along with gas). While the variations can be large and important, very few studies, especially kinetic studies, have been published. In this paper we examine the changes brought about in argon plasma by injecting Ar (gas), N 2 (gas) hexane (gas) and hexane (liquid droplets). The changes in the RF capacitively coupled power (forward and reflected), electron and ion density (n e , n i ), electron temperature (T e ) and optical emissions were monitored during the injections. It was found that the Ar injection (pressure change only) caused expected variations. The electron temperature reduced, the plasma density increased and the optical emission intensity remained nearly constant. The N 2 and hexane gas injections (chemical composition and pressure changes) also followed expected trends. The plasma densities increased and electron temperature decreased while the optical emissions changed from argon to the injected gas. These all serve to highlight the fact that the injection of evaporating hexane droplets in the plasma caused very little change. This is because the number of injected droplets is too small to noticeably affect the plasma, even though the shift in the chemical composition of the gas caused by evaporation from those same droplets can be very significant. The net conclusion is that using liquid droplets to inject precursors for low pressure plasmas is both feasible and controllable.

  18. Analysis of a gas-liquid film plasma reactor for organic compound oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Kevin [Department of Chemical and Biomedical Engineering, Florida State University, Tallahassee, FL 32310 (United States); Wang, Huijuan [School of Environmental and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); Locke, Bruce R., E-mail: blocke@fsu.edu [Department of Chemical and Biomedical Engineering, Florida State University, Tallahassee, FL 32310 (United States)

    2016-11-05

    Highlights: • Non-homogeneous filamentary plasma discharge formed along gas-liquid interface. • Hydrogen peroxide formed near interface favored over organic oxidation from liquid. • Post-plasma Fenton reactions lead to complete utilization of hydrogen peroxide. - Abstract: A pulsed electrical discharge plasma formed in a tubular reactor with flowing argon carrier gas and a liquid water film was analyzed using methylene blue as a liquid phase hydroxyl radical scavenger and simultaneous measurements of hydrogen peroxide formation. The effects of liquid flow rate, liquid conductivity, concentration of dye, and the addition of ferrous ion on dye decoloration and degradation were determined. Higher liquid flow rates and concentrations of dye resulted in less decoloration percentages and hydrogen peroxide formation due to initial liquid conductivity effects and lower residence times in the reactor. The highest decoloration energy yield of dye found in these studies was 5.2 g/kWh when using the higher liquid flow rate and adding the catalyst. The non-homogeneous nature of the plasma discharge favors the production of hydrogen peroxide in the plasma-liquid interface over the chemical oxidation of the organic in the bulk liquid phase and post-plasma reactions with the Fenton catalyst lead to complete utilization of the plasma-formed hydrogen peroxide.

  19. Estimation of gas wall shear stress in horizontal stratified gas-liquid pipe flow

    International Nuclear Information System (INIS)

    Newton, C.H.; Behnia, M.

    1996-01-01

    Two-phase pipe flows occur in many industrial applications, such as condensers and evaporators, chemical processing equipment, nuclear reactors, and oil pipelines. A variety of basic mechanistic flow models for predicting the pressure gradient and liquid loading characteristics of these types of flows to assist in design calculations has emerged over the past two decades, especially for the stratified and slug flow regimes. These models generally rely on a number of basic assumptions and empirical closure equations. Possibly the most notable of these relates to the evaluation of interfacial shear stresses. However, one of the most important yet least discussed assumptions used in most of these models is that the phase wall shear stresses can be accurately estimated from correlations developed for single-phase pipe flows. The object of this article is to present measurements of gas wall shear up to locations in close proximity to the gas-liquid interface for a variety of interface conditions in developed flow, and to determine the effects of the interface on average gas wall friction factors. In this context the interface may be smooth, rippled or wavy

  20. Thermal gradient brine inclusion migration in salt study: gas-liquid inclusions, preliminary model

    International Nuclear Information System (INIS)

    Olander, D.R.; Machiels, A.J.

    1979-10-01

    Natural salt deposits contain small cubical inclusions of brine distributed through the salt. Temperature gradients, resulting from storing heat-generating wastes in the salt, can cause the inclusions to move through the salt. Prediction of the rate and amount of brine-inclusion migration is necessary for the evaluation of bedded or domed salts as possible media for waste repositories. Inclusions filled exclusively with liquid migrate up the temperature gradient towards the heat source. The solubility of salt in the brine inclusion increases with temperature. Consequently, salt dissolves into the inclusion across the hot surface and crystallizes out at the cold surface. Diffusion of salt within the liquid phase from the hot to the cold faces causes the inclusions to move in the opposite direction. In so doing, they change shape and eventually become rectangular parallelipipeds with a width (dimension perpendicular to the thermal gradient) much larger than the thickness (dimension in the direction of the thermal gradient). The inclusions may also contain a gas phase predominantly consisting of water vapor. These entities are termed two-phase or gas-liquid inclusions. The two-phase inclusions usually migrate down the temperature gradient away from the heat source remaining more-or-less cubical. A two-phase inclusion also forms when an all-liquid inclusion reaches the waste package; upon opening up at the salt-package interface, the brine partially evaporates and the inclusion reseals with some insoluble gas trapped inside. These gas-liquid inclusions proceed to move down the temperature gradient, in the opposite sense of the all-liquid inclusions. The gas-liquid inclusions phenomenon provides a pathway by which radionuclides leached from the wasteform by the brine can be transported away from the waste package and thus might have greater access to the biosphere

  1. Effects of gas flow on oxidation reaction in liquid induced by He/O{sub 2} plasma-jet irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Atsushi; Uchida, Giichiro, E-mail: uchida@jwri.osaka-u.ac.jp; Takenaka, Kosuke; Setsuhara, Yuichi [Joining and Welding Research Institute, Osaka University, Ibaraki, Osaka 567-0047 (Japan); Kawasaki, Toshiyuki [Department of Mechanical and Electrical Engineering, Nippon Bunri University, Oita, Oita 870-0397 (Japan); Koga, Kazunori; Sarinont, Thapanut; Amano, Takaaki; Shiratani, Masaharu [Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Fukuoka 819-0395 (Japan)

    2015-07-28

    We present here analysis of oxidation reaction in liquid by a plasma-jet irradiation under various gas flow patterns such as laminar and turbulence flows. To estimate the total amount of oxidation reaction induced by reactive oxygen species (ROS) in liquid, we employ a KI-starch solution system, where the absorbance of the KI-starch solution near 600 nm behaves linear to the total amount of oxidation reaction in liquid. The laminar flow with higher gas velocity induces an increase in the ROS distribution area on the liquid surface, which results in a large amount of oxidation reaction in liquid. However, a much faster gas flow conversely results in a reduction in the total amount of oxidation reaction in liquid under the following two conditions: first condition is that the turbulence flow is triggered in a gas flow channel at a high Reynolds number of gas flow, which leads to a marked change of the spatial distribution of the ROS concentration in gas phase. Second condition is that the dimpled liquid surface is formed by strong gas flow, which prevents the ROS from being transported in radial direction along the liquid surface.

  2. Role of isospin in nuclear-matter liquid-gas phase transition

    International Nuclear Information System (INIS)

    Ducoin, C.

    2006-10-01

    Nuclear matter presents a phase transition of the liquid-gas type. This well-known feature is due to the nuclear interaction profile (mean-range attractive, short-range repulsive). Symmetric-nuclear-matter thermodynamics is thus analogous to that of a Van der Waals fluid. The study shows up to be more complex in the case of asymmetric matter, composed of neutrons and protons in an arbitrary proportion. Isospin, which distinguishes both constituents, gives a measure of this proportion. Studying asymmetric matter, isospin is an additional degree of freedom, which means one more dimension to consider in the space of observables. The nuclear liquid-gas transition is associated with the multi-fragmentation phenomenon observed in heavy-ion collisions, and to compact-star physics: the involved systems are neutron rich, so they are affected by the isospin degree of freedom. The present work is a theoretical study of isospin effects which appear in the asymmetric nuclear matter liquid-gas phase transition. A mean-field approach is used, with a Skyrme nuclear effective interaction. We demonstrate the presence of a first-order phase transition for asymmetric matter, and study the isospin distillation phenomenon associated with this transition. The case of phase separation at thermodynamic equilibrium is compared to spinodal decomposition. Finite size effects are addressed, as well as the influence of the electron gas which is present in the astrophysical context. (author)

  3. Cold flame on Biofilm - Transport of Plasma Chemistry from Gas to Liquid Phase

    Science.gov (United States)

    Kong, Michael

    2014-10-01

    One of the most active and fastest growing fields in low-temperature plasma science today is biological effects of gas plasmas and their translation in many challenges of societal importance such as healthcare, environment, agriculture, and nanoscale fabrication and synthesis. Using medicine as an example, there are already three FDA-approved plasma-based surgical procedures for tissue ablation and blood coagulation and at least five phase-II clinical trials on plasma-assisted wound healing therapies. A key driver for realizing the immense application potential of near room-temperature ambient pressure gas plasmas, commonly known as cold atmospheric plasmas or CAP, is to build a sizeable interdisciplinary knowledge base with which to unravel, optimize, and indeed design how reactive plasma species interact with cells and their key components such as protein and DNA. Whilst a logical objective, it is a formidable challenge not least since existing knowledge of gas discharges is largely in the gas-phase and therefore not directly applicable to cell-containing matters that are covered by or embedded in liquid (e.g. biofluid). Here, we study plasma inactivation of biofilms, a jelly-like structure that bacteria use to protect themselves and a major source of antimicrobial resistance. As 60--90% of biofilm is made of water, we develop a holistic model incorporating physics and chemistry in the upstream CAP-generating region, a plasma-exit region as a buffer for as-phase transport, and a downstream liquid region bordering the gas buffer region. A special model is developed to account for rapid chemical reactions accompanied the transport of gas-phase plasma species through the gas-liquid interface and for liquid-phase chemical reactions. Numerical simulation is used to illustrate how key reactive oxygen species (ROS) are transported into the liquid, and this is supported with experimental data of both biofilm inactivation using plasmas and electron spin spectroscopy (ESR

  4. Design and operation of off-gas cleaning systems at high level liquid waste conditioning facilities

    International Nuclear Information System (INIS)

    1988-01-01

    The immobilization of high level liquid wastes from the reprocessing of irradiated nuclear fuels is of great interest and serious efforts are being undertaken to find a satisfactory technical solution. Volatilization of fission product elements during immobilization poses the potential for the release of radioactive substances to the environment and necessitates effective off-gas cleaning systems. This report describes typical off-gas cleaning systems used in the most advanced high level liquid waste immobilization plants and considers most of the equipment and components which can be used for the efficient retention of the aerosols and volatile contaminants. In the case of a nuclear facility consisting of several different facilities, release limits are generally prescribed for the nuclear facility as a whole. Since high level liquid waste conditioning (calcination, vitrification, etc.) facilities are usually located at fuel reprocessing sites (where the majority of the high level liquid wastes originates), the off-gas cleaning system should be designed so that the airborne radioactivity discharge of the whole site, including the emission of the waste conditioning facility, can be kept below the permitted limits. This report deals with the sources and composition of different kinds of high level liquid wastes and describes briefly the main high level liquid waste solidification processes examining the sources and characteristics of the off-gas contaminants to be retained by the off-gas cleaning system. The equipment and components of typical off-gas systems used in the most advanced (large pilot or industrial scale) high level liquid waste solidification plants are described. Safety considerations for the design and safe operation of the off-gas systems are discussed. 60 refs, 31 figs, 17 tabs

  5. Experimental studies on hydrogen isotopic deuterium from gas to liquid phase by catalytic exchange

    International Nuclear Information System (INIS)

    Luo Yangming; Wang Heyi; Liu Jun; Fu Zhonghua; Wang Changbin; Han Jun; Xia Xiulong; Tang Lei

    2005-01-01

    The experimental studies on hydrogen isotopic deuterium from gas to liquid phase were completed by mixed ratio 1:4 of Pt-SDB hydrophobic catalyst and hydrophilic packing. The influencing factors on number of transfer units (NTU) and transformation efficiencies of deuterium were researched. The results show that preferable NTU can be obtained by choosing suitable operational temperature and flux of exchange gas. The transformation rate increases with increasing liquid flux, but it cannot obviously be improved when liquid flux attains some level. The length of catalytic column has an obvious influence on transformation rate and 90% of transformation rate is obtained by 4 m column length at gas flux with 2 m 3 /h, liquid flux with 1-2 kg/h and 45 degree C. (author)

  6. North American natural gas liquids pricing and convergence : an energy market assessment

    International Nuclear Information System (INIS)

    2001-05-01

    A background on natural gas liquids (NGL) pricing was presented along with a discussion regarding the impact of energy price convergence. The high energy prices in the fall of 2000 were a result of many factors, including the high price of NGLs. All NGL components such as ethane, propane and butane can be used as petrochemical feedstock. In the winter of 2000/2001 the relationship between liquids and crude oil prices collapsed when high energy prices led to a situation where, for a short while, extraction of liquids from natural gas became uneconomic since producers got more value for NGLs left in the gas stream. As a result, when the supply and demand balances for NGL tightened in many regions of North America, NGL prices were reflecting the unprecedented high natural gas prices. This paper also explained how the four major North American NGL trading hubs in Alberta, Ontario, Kansas and Texas operate. The pricing events of 2000 have impacted on the NGL industry and energy prices remain an issue since both crude oil and natural gas price are forecasted to remain strong in the near future. 5 figs

  7. Sample preparation for large-scale bioanalytical studies based on liquid chromatographic techniques.

    Science.gov (United States)

    Medvedovici, Andrei; Bacalum, Elena; David, Victor

    2018-01-01

    Quality of the analytical data obtained for large-scale and long term bioanalytical studies based on liquid chromatography depends on a number of experimental factors including the choice of sample preparation method. This review discusses this tedious part of bioanalytical studies, applied to large-scale samples and using liquid chromatography coupled with different detector types as core analytical technique. The main sample preparation methods included in this paper are protein precipitation, liquid-liquid extraction, solid-phase extraction, derivatization and their versions. They are discussed by analytical performances, fields of applications, advantages and disadvantages. The cited literature covers mainly the analytical achievements during the last decade, although several previous papers became more valuable in time and they are included in this review. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Data acquisition and quantitative analysis of stable hydrogen isotope in liquid and gas in the liquid phase catalytic exchange process

    International Nuclear Information System (INIS)

    Choi, H. J.; Lee, H. S.; Kim, K. R.; Cheong, H. S.; Ahn, D. H.; Lee, S. H.; Paek, S. W.; Kang, H. S.; Kim, J. G.

    2001-01-01

    A pilot plant for the Liquid Phase Catalytic Exchange process was built and has been operating to test the hydrophobic catalyst developed to remove the tritium generated at the CANDU nuclear power plants. The methods of quantitative analysis of hydrogen stable isotope were compared. Infrared spectroscopy was used for the liquid samples, and gas chromatography with hydrogen carrier gas showed the best result for gas samples. Also, a data acquisition system was developed to record the operation parameters. This record was very useful to investigate the causes of the system trip

  9. Effect of geometric parameters of liquid-gas separator units on phase separation performance

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Songping; Chen, Xueqing; Chen, Ying [Guangdong University of Technology, Seoul (China); Yang, Zhen [Tsinghua University, Beijing (China)

    2015-07-15

    Five liquid-gas separator units were designed and constructed based on a new concept of a validated high-performance condenser. Each separator unit consists of two united T-junctions and an apertured baffle. The separator units have different header diameters or different baffles with different diameters of the liquid-gas separation hole. The phase separation characteristics of the units were investigated at inlet air superficial velocities from 1.0m/s to 33.0m/s and water superficial velocities from 0.0015 m/s to 0..50 m/s. The experimental results showed that the liquid height, liquid flow rate through the separation hole, and liquid separation efficiency increased with increased header diameter and decreased diameter of the separation hole. The geometric structures of the separator units affected the phase separation characteristics by influencing the liquid height in the header and the liquid flow rate through the separation hole.

  10. Determination of Interfacial Area in Gas-Liquid Two Phase by Light Transmission

    International Nuclear Information System (INIS)

    Ghiasi, H.; Safekordi, A. A.; Babazadeh Shareh, F.

    2012-01-01

    The purpose of the present paper is to develop light beam method to measurement of interfacial area in a rectangular gas-liquid bubble column. Total interfacial area can be determined in bubble column filled by transparent liquid by light transmission method. According to pervious researches, the fraction of parallel light is function of interfacial area and optical path length that these two parameters imply Transmission Number or N T . The drop diameters were measured in the range of 2.2 to 5 mm, and in this range, the specific area is found to depend only upon the light transmission. Three different systems with various liquid phases have been used in this work. It had been proved that light transmission method for dilute suspension or stationary gas phase has a good consequence. In this work, good agreement between actual and calculated interfacial area proves that light transmission method would be able to determine interfacial area in multiple scattering, and it is possible to use earlier mathematic model to measure interfacial area in multiple scattering in gas-liquid bubble columns.

  11. The preparation, physicochemical properties, and the cohesive energy of liquid sodium containing titanium nanoparticles

    International Nuclear Information System (INIS)

    Saito, Jun-ichi; Itami, Toshio; Ara, Kuniaki

    2012-01-01

    Liquid sodium containing titanium nanoparticles (LSnanop) of 10-nm diameter was prepared by dispersing titanium nanoparticles (2 at.% Ti) into liquid sodium with the addition of stirring and ultrasonic sound wave. The titanium nanoparticles themselves were prepared by the vapor deposition method. This new liquid metal, LSnanop, shows a remarkable stability due to the Brownian motion of nanoparticles in liquid sodium medium. In addition, the difference of measured heat of reaction to water between this LSnanop and liquid sodium indicates the existence of cohesive energy between the liquid sodium medium and dispersed titanium nanoparticles. The origin of the cohesive energy, which serves to stabilize this new liquid metal, was explained by the model of screened nanoparticles in liquid sodium. In this model, negatively charged nanoparticles with transferred electrons from liquid sodium are surrounded by the positively charged screening shell, which may inhibit the gathering of nanoparticles by the “Coulombic repulsion coating.” The atomic volume of LSnanop shows the shrinkage from the linear law, which also suggests the existence of cohesive energy. The viscosity of LSnanop is almost the same as that of liquid sodium. This behavior was explained by the Einstein equation. The surface tension of LSnanop is 17 % larger than that of liquid sodium. The cohesive energy and the negative adsorption may be responsible to this increase. Titanium nanoparticles in liquid sodium seem to be free from the Coulomb fission. This new liquid metal containing nanoparticles suggests the possibility to prepare various stable suspensions with new properties.

  12. Local studies in horizontal gas-liquid slug flow

    International Nuclear Information System (INIS)

    Sharma, S.; Lewis, S.; Kojasoy, G.

    1998-01-01

    The local axial velocity profile development in a horizontal air-water slug flow-pattern was experimentally investigated by simultaneously using two hot-film anemometers. One of the probes was exclusively used as phase identifier while the other probe was traversed for local velocity measurements. It was shown that the velocity rapidly develops into asymmetric but nearly fully-developed profiles within the liquid slugs whereas the velocity never develops into quasi-fully-developed profiles within the liquid layer underneath passing gas slugs. Transient nature of velocity at a given location was demonstrated. (author)

  13. Seismo-Geochemical Variations in SW Taiwan: Multi-Parameter Automatic Gas Monitoring Results

    Science.gov (United States)

    Yang, T. F.; Fu, C.-C.; Walia, V.; Chen, C.-H.; Chyi, L. L.; Liu, T.-K.; Song, S.-R.; Lee, M.; Lin, C.-W.; Lin, C.-C.

    2006-04-01

    Gas variations of many mud volcanoes and hot springs distributed along the tectonic sutures in southwestern Taiwan are considered to be sensitive to the earthquake activity. Therefore, a multi-parameter automatic gas station was built on the bank of one of the largest mud-pools at an active fault zone of southwestern Taiwan, for continuous monitoring of CO2, CH4, N2 and H2O, the major constituents of its bubbling gases. During the year round monitoring from October 2001 to October 2002, the gas composition, especially, CH4 and CO2, of the mud pool showed significant variations. Taking the CO2/CH4 ratio as the main indicator, anomalous variations can be recognized from a few days to a few weeks before earthquakes and correlated well with those with a local magnitude >4.0 and local intensities >2. It is concluded that the gas composition in the area is sensitive to the local crustal stress/strain and is worthy to conduct real-time monitoring for the seismo-geochemical precursors.

  14. Forecasting: Canada's NGL [natural gas liquids] supply outlook

    International Nuclear Information System (INIS)

    Anderson, A.B.

    1992-01-01

    A perspective is given on Canada's supply and demand balance of ethane, propane, and butane, and Canada's participation in meeting the expected increases in United States import requirements. Increases in Canadian natural gas liquids (NGL) supply depends on increases in natural gas production. Since new production (except for the Shell Caroline gas discovery) is tending to have lower yields of liquids, NGL supply will not increase as much as the increase in natural gas production. Nearly 50% of Canadian NGLs are produced in straddle plants located at the inlet of gas transmission lines. Surpluses of ethane and high capital costs means that new straddle plants will not be built in the near future, but expansions of existing plants will occur to maximize propane and butane production. The potential ethane supply will increase, notably from the Shell Caroline project. The primary market for ethane in Canada is the Alberta petrochemical industry, and a new ethylene plant to be started up in 1994 will increase demand. The use of ethane for miscible flooding will decrease to the end of the decade. Propane production is expected to increase to a total of 180,000 bbl/d by 2000; demand growth in traditional markets such as heating and cooking is expected to be marginal, and the petrochemical sector is expected to show the largest growth in propane demand. The use of butane for producing methyl tertiary butyl ether is expected to increase butane demand for the rest of the decade. Exports of NGL to the USA are largely via the Cochin pipeline system. Modest increases in NGL exports are expected. A number of gas pipeline projects are at various stages of planning, and completion of these projects would enable an increase in Canadian exports. 8 figs

  15. A flow reactor setup for photochemistry of biphasic gas/liquid reactions

    Directory of Open Access Journals (Sweden)

    Josef Schachtner

    2016-08-01

    Full Text Available A home-built microreactor system for light-mediated biphasic gas/liquid reactions was assembled from simple commercial components. This paper describes in full detail the nature and function of the required building elements, the assembly of parts, and the tuning and interdependencies of the most important reactor and reaction parameters. Unlike many commercial thin-film and microchannel reactors, the described set-up operates residence times of up to 30 min which cover the typical rates of many organic reactions. The tubular microreactor was successfully applied to the photooxygenation of hydrocarbons (Schenck ene reaction. Major emphasis was laid on the realization of a constant and highly reproducible gas/liquid slug flow and the effective illumination by an appropriate light source. The optimized set of conditions enabled the shortening of reaction times by more than 99% with equal chemoselectivities. The modular home-made flow reactor can serve as a prototype model for the continuous operation of various other reactions at light/liquid/gas interfaces in student, research, and industrial laboratories.

  16. Un nouveau moyen de mesure absolue du taux gazeux des mélanges gaz-liquides : le SMAC A New Absolute Measurement of the Volumetric Gas Ratio of Gas-Liquid Mixture: the Smac

    Directory of Open Access Journals (Sweden)

    Porot P.

    2006-11-01

    and P index 0 the sample initial pressure. Numerical simulations indicate that the pressurization must be regular and fast enough to avoid the problems coming from dissolution. They also indicate that small leakage could be profitable by decreasing the maximum pressure needed to meet the inflexion without modifying the measurement. The experimental verification consists in measuring the (P,V graphs during the pressurization of different known mixture samples. The positions of the inflexion points of the log log graphs were compared with the known volumetric gas ratio. The correlation is very good and the deviations were inside the error range of the preparation of the mixture samples. Based on this principle, a system of oil aeration measurement has been developped : the SMAC (french name for Compressibility based oil Aeration Measurement System. The system is able to take samples from a given circuit by electrovalves. The sample is then regularly pressurized by a piston; pressure, piston displacement and temperature are stored along the time in a PC. The inflexion point is then determined, the gas ratio calculated and printed by a soft on the PC. The whole operation takes around three minutes. This apparatus has been used for two studies. The first one was dealing with hydraulic valve lash adhusters (HLA. The SMAC was measuring the gas ratio of oil in the circuit. The aim was to evaluate the influence of aeration on the HLA. The second study consists in defining a new oil aeration test method to measure the influence of silicone additives on aeration. Generally speaking, the SMAC principle can be used on almost any gas liquid mixture to measure the volumetric gas ration.

  17. FORTRAN program for calculating liquid-phase and gas-phase thermal diffusion column coefficients

    International Nuclear Information System (INIS)

    Rutherford, W.M.

    1980-01-01

    A computer program (COLCO) was developed for calculating thermal diffusion column coefficients from theory. The program, which is written in FORTRAN IV, can be used for both liquid-phase and gas-phase thermal diffusion columns. Column coefficients for the gas phase can be based on gas properties calculated from kinetic theory using tables of omega integrals or on tables of compiled physical properties as functions of temperature. Column coefficients for the liquid phase can be based on compiled physical property tables. Program listings, test data, sample output, and users manual are supplied for appendices

  18. Study of the rise of gas bubbles in a viscous liquid. Stability and speed. Bibliographical study

    International Nuclear Information System (INIS)

    Dahan, Gilbert

    1969-01-01

    This short thesis reports a bibliographical study on the movement of gas bubbles in viscous liquids. The author addresses the formation of gas bubbles in liquids of different viscosity (devices used for the formation of bubbles in viscous liquids, formation of bubbles at a hole), and the behaviour of bubbles rising in viscous liquids and more particularly the speed and shape of these bubbles [fr

  19. Forming of film surface of very viscous liquid flowing with gas in pipes

    Directory of Open Access Journals (Sweden)

    Czernek Krystian

    2017-01-01

    Full Text Available The study presents the possible use of optoelectronic system for the measurement of the values, which are specific for hydrodynamics of two-phase gas liquid flow in vertical pipes, where a very-high-viscosity liquid forms a falling film in a pipe. The experimental method was provided, and the findings were presented and analysed for selected values, which characterize the two-phase flow. Attempt was also made to evaluate the effects of flow parameters and properties of the liquid on the gas-liquid interface value, which is decisive for the conditions of heat exchange and mass transfer in falling film equipment. The nature and form of created waves at various velocities were also described.

  20. Bubble-induced mixing of two horizontal liquid layers with non-uniform gas injection at the bottom

    International Nuclear Information System (INIS)

    Cheung, F.B.; Leinweber, G.; Pedersen, D.R.

    1984-01-01

    During a postulated severe core meltdown accident in an LMFBR, a large amount of sodium coolant may spill into the reactor concrete cavity. A layer of liquid products may form as a result of the sodium-concrete reactions. The liquid product layer, which is highly viscous and much heavier than sodium, separates the concrete from the sodium pool. In general, the downward transport of sodium through the liquid product layer to the unreacted concrete surface, which controls the rate of chemical erosion of the concrete, depends strongly on the agitation induced by gas evolution from the heated concrete. In this study, experiments were conducted to explore the effect of non-uniform gas injection on mixing of two horizontal mutually soluble liquid layers. The liquid in the lower layer was chosen to be more viscous and heavier than the liquid in the upper layer. To simulate the reactor accident situation, gas was injected at the bottom of the liquid-liquid system through a circular hole that covered only the center portion of the bottom surface of the lower liquid layer. The bubble-induced mixing motions were observed and the rate of mixing was measured for different hole sizes and for various gas flow rates

  1. Droplets in annular-dispersed gas-liquid pipe-flows

    NARCIS (Netherlands)

    Van 't Westende, J.M.C.

    2008-01-01

    Annular-dispersed gas-liquid pipe-flows are commonly encountered in many industrial applications, and have already been studied for many decades. However, due to the great complexity of this type of flow, there are still many phenomena that are poorly understood. The aim of this thesis is to shed

  2. Experimental investigation of the liquid volumetric mass transfer coefficient for upward gas-liquid two-phase flow in rectangular microchannels

    Directory of Open Access Journals (Sweden)

    X. Y. Ji

    2010-12-01

    Full Text Available The gas-liquid two-phase mass transfer process in microchannels is complicated due to the special dynamical characteristics. In this work, a novel method was explored to measure the liquid side volumetric mass transfer coefficient kLa. Pressure transducers were utilized to measure the pressure variation of upward gas-liquid two-phase flow in three vertical rectangular microchannels and the liquid side volumetric mass transfer coefficient kLa was calculated through the Pressure-Volume-Temperature correlation of the gas phase. Carbon dioxide-water, carbon dioxide-ethanol and carbon dioxide-n-propanol were used as working fluids, respectively. The dimensions of the microchannels were 40 µm×240 µm (depth×width, 100 µm×800 µm and 100 µm×2000 µm, respectively. Results showed that the channel diameter and the capillary number influence kLa remarkably and that the maximum value of kLa occurs in the annular flow regime. A new correlation of kLa was proposed based on the Sherwood number, Schmidt number and the capillary number. The predicted values of kLa agreed well with the experimental data.

  3. Gas-liquid two-phase flows in double inlet cyclones for natural gas separation

    DEFF Research Database (Denmark)

    Yang, Yan; Wang, Shuli; Wen, Chuang

    2017-01-01

    The gas-liquid two-phase flow within a double inlet cyclone for natural gasseparation was numerically simulated using the discrete phase model. The numericalapproach was validated with the experimental data, and the comparison resultsagreed well with each other. The simulation results showed...... that the strong swirlingflow produced a high centrifugal force to remove the particles from the gas mixture.The larger particles moved downward on the internal surface and were removeddue to the outer vortex near the wall. Most of the tiny particles went into the innervortex zones and escaped from the up...

  4. A weakly compressible formulation for modelling liquid-gas sloshing

    CSIR Research Space (South Africa)

    Heyns, Johan A

    2012-09-01

    Full Text Available This study presents the development and extension of free-surface modelling techniques with the purpose of improving the modelling accuracy for liquid-gas sloshing. Considering high density ratio fluids under low Mach number conditions...

  5. Numerical Simulation and Analysis of Gas-Liquid Flow in a T-Junction Microchannel

    Directory of Open Access Journals (Sweden)

    Hongtruong Pham

    2012-01-01

    Full Text Available Gas-liquid flow in microchannels is widely used in biomedicine, nanotech, sewage treatment, and so forth. Particularly, owing to the high qualities of the microbubbles and spheres produced in microchannels, it has a great potential to be used in ultrasound imaging and controlled drug release areas; therefore, gas-liquid flow in microchannels has been the focus in recent years. In this paper, numerical simulation of gas-liquid flows in a T-junction microchannel was carried out with computational fluid dynamics (CFD software FLUENT and the Volume-of-Fluid (VOF model. The distribution of velocity, pressure, and phase of fluid in the microchannel was obtained, the pressure distribution along the channel walls was analyzed in order to give a better understanding on the formation of microbubbles in the T-junction microchannel.

  6. Understanding the formation process of the liquid slug in a hilly-terrain wet natural gas pipeline

    DEFF Research Database (Denmark)

    Yang, Yan; Li, Jingbo; Wang, Shuli

    2017-01-01

    condition on the liquid slug formation is discussed including pipe diameter, inclination angle, gas superficial velocity and liquid holdup. The results show that the pipe is blocked by the liquid slug at the moment of slug formed. The pipe pressure suddenly increases, and then decreases gradually...... in the process of liquid slug formation and motion. The pipe pressure drop and liquid holdup decrease along with the increasing inclination angle of ascending pipe. On the contrary, they rise with the increase of the inclination angle of descending pipe. Higher gas superficial velocity and liquid holdup result...

  7. Determination of vanadium(V) by direct automatic potentiometric titration with EDTA using a chemically modified electrode as a potentiometric sensor.

    Science.gov (United States)

    Quintar, S E; Santagata, J P; Cortinez, V A

    2005-10-15

    A chemically modified electrode (CME) was prepared and studied as a potentiometric sensor for the end-point detection in the automatic titration of vanadium(V) with EDTA. The CME was constructed with a paste prepared by mixing spectral-grade graphite powder, Nujol oil and N-2-naphthoyl-N-p-tolylhydroxamic acid (NTHA). Buffer systems, pH effects and the concentration range were studied. Interference ions were separated by applying a liquid-liquid extraction procedure. The CME did not require any special conditioning before using. The electrode was constructed with very inexpensive materials and was easily made. It could be continuously used, at least two months without removing the paste. Automatic potentiometric titration curves were obtained for V(V) within 5 x 10(-5) to 2 x 10(-3)M with acceptable accuracy and precision. The developed method was applied to V(V) determination in alloys for hip prosthesis.

  8. Film behaviour of vertical gas-liquid flow in a large diameter pipe

    OpenAIRE

    Zangana, Mohammed Haseeb Sedeeq

    2011-01-01

    Gas-liquid flow commonly occurs in oil and gas production and processing system. Large diameter vertical pipes can reduce pressure drops and so minimize operating costs. However, there is a need for research on two-phase flow in large diameter pipes to provide confidence to designers of equipments such as deep water risers. In this study a number of experimental campaigns were carried out to measure pressure drop, liquid film thickness and wall shear in 127mm vertical pipe. Total pressur...

  9. Preparation of β-belite using liquid alkali silicates

    International Nuclear Information System (INIS)

    Koutník, P.

    2017-01-01

    The aim of this study is the preparation of β-belite by a solid-state reaction using powdered limestone, amorphous silica and liquid alkali silicates. The raw materials were blended, the mixtures were agglomerated and then burnt. The resulting samples were characterized by X-ray diffraction analysis and scanning electron microscopy. Free lime content in the β-belite samples was also determined. The effects of CaO/SiO2 ratio (1.6–2.1), burning temperature (800–1400 °C), utilization of different raw materials (silica fume, synthetic silica, potassium silicate, sodium silicate, potassium hydroxide) and burning time (0.5–16 h) on free lime content and mineralogical composition were investigated. The purest ?-belite samples were prepared from a mixture of powdered limestone, silica fume and liquid potassium silicate with a ratio CaO/SiO2 = 2 by burning at temperatures between 1100 and 1300 °C for more than 2 h. Decreasing of the CaO/SiO2 ratio led to rankinite formation and lower a burning temperature led to the formation of wollastonite. [es

  10. Preparation of antimony sulfide semiconductor nanoparticles by pulsed laser ablation in liquid

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Ren-De, E-mail: son003@sekisui.com [Research & Development Institute, High Performance Plastics Company, Sekisui Chemical Co., Ltd. 2-1 Hyakuyama, Shimamoto-Cho, Mishima-Gun, Osaka, 618-0021 (Japan); Tsuji, Takeshi [Interdisciplinary Graduate School of Science and Engineering, Shimane University, 1060 Nishikawatsu-Cho, Matsue, 690-8504 (Japan)

    2015-09-01

    Highlights: • Pulsed laser ablation in liquid (LAL) was applied to prepare antimony sulfide nanoparticles (Sb{sub 2}S{sub 3} NPs). • Sb{sub 2}S{sub 3} NPs with a stoichiometric composition were successfully prepared by LAL in water without using any surfactants or capping agents. • Thus-prepared Sb{sub 2}S{sub 3} NPs showed low-temperature crystallization and melting at a temperature low as 200 °C. • The NPs-coated Sb{sub 2}S{sub 3} thin film showed comparable semiconductor properties (carrier mobility and carrier density) to the vacuum deposited one. • Byproducts such as CS{sub 2}, CH{sub 4} and CO were detected by GC-MS analysis when LAL was performed in organic solvent. • The LAL-induced decomposition mechanism of Sb{sub 2}S{sub 3} and organic solvents was discussed based on the GC-MS results. - Abstract: In this paper, we report on the synthesis of antimony sulfide (Sb{sub 2}S{sub 3}) semiconductor nanoparticles by pulsed laser ablation in liquid without using any surfactants or capping agents. Different results were obtained in water and organic solvents. In the case of water, Sb{sub 2}S{sub 3} nanoparticles with chemical compositions of stoichiometry were successfully prepared when laser irradiation was performed under the condition with the dissolved oxygen removed by argon gas bubbling. It was shown that thus-obtained Sb{sub 2}S{sub 3} nanoparticles exhibit features of not only low-temperature crystallization but also low-temperature melting at a temperature as low as 200 °C. Nanoparticle-coated Sb{sub 2}S{sub 3} thin films were found to show good visible light absorption and satisfying semiconductor properties (i.e., carrier mobility and density), which are essential for photovoltaic application. On the other hand, in the case of organic solvents (e.g., acetone, ethanol), such unexpected byproducts as CS{sub 2}, CO and CH{sub 4} were detected from the reaction system by GC-MS analysis, which suggests that both Sb{sub 2}S{sub 3} and organic

  11. Overview of U.S. DOE's Natural Gas-to-Liquids RD and D program and commercialization strategy

    International Nuclear Information System (INIS)

    Venkataraman, V.K.; Guthrie, H.D.; Avellanet, R.A.; Driscoll, D.J.

    1998-01-01

    Natural gas, which is comprised mostly of methane, is one of our most abundant natural resources, both in the U.S. and world wide. In the United States alone, recoverable natural gas resources are several times its current estimate of reserves, 166 trillion cubic feet (TCF). Unfortunately, many of these resources are located offshore or in remote areas. High transportation costs, or complete lack of any transportation mechanism, prohibits extensive use of this 'stranded' natural resource. To overcome this limitation, the U.S. Department of Energy's (DOE) Federal Energy Technology Center (FETC) has developed a highly diversified gas-to-liquids research program to evaluate, promote and develop processes that convert natural gas into higher value products (i.e., liquid fuels) which will offset the high transportation costs and allow use of this untapped, environmentally friendly resource. By advancing technologies to convert unmarketable gas resources into valuable products, cooperative efforts between DOE and industry could yield the following benefits by 20 10: (1) Our shortfall in domestic production of oil will be reduced by 200,000 to 500,000 barrels per day of high quality transportation fuel made from Alaska's North Slope gas resources; (2) Advanced gas-to-liquids conversion technology that yields ultra clean burning diesel fuels that meet the most stringent emissions requirements, at costs competitive with those of comparable fuels made from crude oils, will be utilized; and (3) Small-scale gas-to-liquids technology for both natural gas liquefaction and chemical conversion to higher hydrocarbon liquids will provide an economic and environmentally sound option for utilization of the associated gas of remote offshore oil reservoirs, and also for onshore gas reservoirs without pipeline access. In summary, development of efficient gas conversion technologies will enhance U.S. energy security, reduce dependence on oil imports and strengthen the economic

  12. Multiscale Simulation of Gas Film Lubrication During Liquid Droplet Collision

    Science.gov (United States)

    Chen, Xiaodong; Khare, Prashant; Ma, Dongjun; Yang, Vigor

    2012-02-01

    Droplet collision plays an elementary role in dense spray combustion process. When two droplets approach each other, a gas film forms in between. The pressure generated within the film prevents motion of approaching droplets. This fluid mechanics is fluid film lubrication that occurs when opposing bearing surfaces are completely separated by fluid film. The lubrication flow in gas film decides the collision outcome, coalescence or bouncing. Present study focuses on gas film drainage process over a wide range of Weber numbers during equal- and unequal-sized droplet collision. The formulation is based on complete set of conservation equations for both liquid and surrounding gas phases. An improved volume-of-fluid technique, augmented by an adaptive mesh refinement algorithm, is used to track liquid/gas interfaces. A unique thickness-based refinement algorithm based on topology of interfacial flow is developed and implemented to efficiently resolve the multiscale problem. The grid size on interface is up O(10-4) of droplet size with a max resolution of 0.015 μm. An advanced visualization technique using the Ray-tracing methodology is used to gain direct insights to detailed physics. Theories are established by analyzing the characteristics of shape changing and flow evolution.

  13. Laboratory validation of a new gas-enhanced dentine liquid permeation evaluation system.

    Science.gov (United States)

    Al-Jadaa, Anas; Attin, Thomas; Peltomäki, Timo; Heumann, Christian; Schmidlin, Patrick R

    2014-12-01

    To validate a new automated dentine permeability testing platform based on pressure change measurements. A split chamber was designed allowing for concomitant measurement of fluid permeation and pressure difference. In a first test, system reliability was assessed by interposing a solid metal disk, embedded composite resin disks, or teeth by consecutively measuring eight times under standardized conditions. Secondly, the repeatability and applicability of the method was tested in a dentine wound model by using intact third molars: Class I (2 × 5 mm) and a full occlusal preparation as well a ceramic restoration were consecutively performed and repeatedly measured eight times each. In the last test, the system detection limit as well correlation between gas pressure difference and liquid permeation were evaluated: Again, third molars were used and occlusal preparations of increasing size (2 × 5, 3 × 5, 4 × 5, and 5 × 5 mm and full occlusal preparations, respectively) were made. Data was analyzed for the linearity of measurement, and R (2) values were calculated. The embedding procedure allowed for perfect separation of the two chambers, and no significant variation in repeated measurements of evaluated samples for the respective treatments (p = 0.05) was found. The detection was 0.002 hPa/min for the pressure slope and 0.0225 μl/min for the fluid infiltration, respectively. The saline volume was highly correlating to the gas pressure changes (R (2) = 0.996, p < 0.0001). The presented method is a reliable and exact tool to assess dentine permeability by nondestructive and repeatable measurements. This method is suitable for measurements and comparison of the effectiveness of dentine wounds sealing materials.

  14. Study of deformation of droplet in external force field by using liquid-gas model of lattice-gas

    International Nuclear Information System (INIS)

    Ebihara, Ken-ichi; Watanabe, Tadashi

    2000-10-01

    The deformation of the droplet by the external force which is assumed to be gravity is studied by using the liquid-gas model of lattice-gas. Two types of liquid-gas models, one is the minimal model and the other is the maximal model, which are distinguished from each other by the added long-range interactions are used for the simulation of the droplet deformation. The difference of the droplet deformation between the maximal model and the minimal model was observed. While the droplet of the minimal model elongates in the direction of the external force, the droplet of the maximal model elongates in the perpendicular direction to the external force. Therefore the droplet deformation in the external force field of the maximal model is more similar to the droplet deformation which is observed in experiments than that of the minimal model. (author)

  15. Simulation, integration, and economic analysis of gas-to-liquid processes

    International Nuclear Information System (INIS)

    Bao, Buping; El-Halwagi, Mahmoud M.; Elbashir, Nimir O.

    2010-01-01

    Gas-to-liquid (GTL) involves the chemical conversion of natural gas into synthetic crude that can be upgraded and separated into different useful hydrocarbon fractions including liquid transportation fuels. Such technology can also be used to convert other abundant natural resources such as coal and biomass to fuels and value added chemicals (referred to as coal-to-liquid (CTL) and biomass-to-liquid (BTL)). A leading GTL technology is the Fischer-Tropsch (FT) process. The objective of this work is to provide a techno-economic analysis of the GTL process and to identify optimization and integration opportunities for cost saving and reduction of energy usage while accounting for the environmental impact. First, a base-case flowsheet is synthesized to include the key processing steps of the plant. Then, a computer-aided process simulation is carried out to determine the key mass and energy flows, performance criteria, and equipment specifications. Next, energy and mass integration studies are performed to address the following items: (a) heating and cooling utilities, (b) combined heat and power (process cogeneration), (c) management of process water, (c) optimization of tail gas allocation, and (d) recovery of catalyst-supporting hydrocarbon solvents. Finally, these integration studies are conducted and the results are documented in terms of conserving energy and mass resources as well as providing economic impact. Finally, an economic analysis is undertaken to determine the plant capacity needed to achieve the break-even point and to estimate the return on investment for the base-case study. (author)

  16. Possibility of increasing the fire-suppression efficiency of the foam in automatic extinguishing installations

    Science.gov (United States)

    Kachanov, I. V.; Veremenyuk, V. V.; Karpenchuk, I. V.; Pavlyukov, S. Yu.

    2013-05-01

    The mechanics of movement of a liquid in the diffuser of the injector of an automatic extinguishing installation with preaeration of the fire-fighting substance was theoretically investigated. An integral solution of the equation for movement of the preaerated fire-fighting gas-liquid mixture in the indicated diffuser has been obtained. A mathematical model of two-phase liquid flow in this diffuser, which allows one to calculate the distribution of the average pressure in the diffuser along its length and to determine the loss in this pressure, has been developed. This model can be used for designing the output region of a hydraulic system with a hydrodynamic drag providing the operation of its injector in a definite regime.

  17. Liquid entrainment through orifices by sparging gas

    International Nuclear Information System (INIS)

    Bonnet, J.M.; Malara, M.; Amblard, M.; Seiler, J.M.

    2001-01-01

    Corium Coolability by water flood during an MCCI (Molten Corium Concrete Interaction) is still an open problem. Several physical mechanisms have been identified which may reduce significantly and finally stop the ablation of concrete. Among these mechanisms, corium ejection by sparging gas into the overlying water may represent an important contribution. This mechanism was at the origin of a large and coolable debris bed and volcano formation in the MACE M3B test. This mechanism has also been observed in simulant material tests performed at UCSB and at FZK. The objective of the work, which is described in the present paper, is to model this mechanism and to quantify the liquid entrainment rate by sparging gas. (author)

  18. Numerical analysis of experiments with gas injection into liquid metal coolant

    International Nuclear Information System (INIS)

    Usov, E V; Lobanov, P D; Pribaturin, N A; Mosunova, N A; Chuhno, V I; Kutlimetov, A E

    2016-01-01

    Presented paper contains results of a numerical analysis of experiments with gas injection in water and liquid metal which have been performed at the Institute of Thermophysics Russian Academy of Science (IT RAS). Obtained experimental data are very important to predict processes that take place in the BREST-type reactor during the hypothetical accident with damage of the steam generator tubes, and may be used as a benchmark to validate thermo-hydraulic codes. Detailed description of models to simulate transport of gas phase in a vertical liquid column is presented in a current paper. Two-fluid model with closing relation for wall friction and interface friction coefficients was used to simulate processes which take place in a liquid during injection of gaseous phase. It has being shown that proposed models allow obtaining a good agreement between experimental data and calculation results. (paper)

  19. Preparation of a nickel nanopowder by wire explosion in liquid media

    International Nuclear Information System (INIS)

    Cho, Chuhyun; Ha, Yooncheol; Kang, Chungil; Jin, Yunsik; Rim, Geunhie

    2010-01-01

    Nickel wires of 0.8 mm in diameter and 80 mm in length were electrically exploded in liquid media, such as water, ethyl alcohol, isopropyl alcohol, and acetone. The electrical energy discharged through the wire was 10 kJ. The distribution of particle sizes was broad from a few μm to tens of nanometer, regardless of the liquid medium used in this study. The particles could be classified according to their sizes by using a centrifugal separator. The powder prepared in distilled water showed mainly a pure metallic Ni phase although a little oxide phase was observed in the XRD analysis. However, the powders prepared in ethyl alcohol, isopropyl alcohol, and acetone showed complicated unknown phases, which is attributed to a compound of carbon in the organic liquid. The unknown phase was turned into a pure metallic Ni phase after heat treatment at 400 .deg. C.

  20. Modelling dynamic liquid-gas systems: Extensions to the volume-of-fluid solver

    CSIR Research Space (South Africa)

    Heyns, Johan A

    2013-06-01

    Full Text Available This study presents the extension of the volume-of-fluid solver, interFoam, for improved accuracy and efficiency when modelling dynamic liquid-gas systems. Examples of these include the transportation of liquids, such as in the case of fuel carried...

  1. Preparation of copper and silicon/copper powders by a gas ...

    Indian Academy of Sciences (India)

    Administrator

    aCentre for Materials Research, Department of Imaging and Applied Physics, ... Copper powder; Si/Cu composite particle; gas evaporation–condensation method; characteriza- tion. .... from the liquid metal surface, the mixed vapour of copper.

  2. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  3. Effect of wall wettability on flow characteristics of gas-liquid two-phase flow

    International Nuclear Information System (INIS)

    Uematsu, Junichi; Abe, Kazuya; Hazuku, Tatsuya; Takamasa, Tomoji; Hibiki, Takashi

    2007-01-01

    To evaluate the effect of surface wettability in pipe wall on flow characteristics in a vertical upward gas-liquid to-phase flow, visualization study was performed using three test pipes, namely an acrylic pipe, a hydrophilic pipe, a hydrophobic pipe. Such basic flow characteristics as flow patterns and void fraction were investigated in these three pipes. In the hydrophilic pipe, the slug flow-to-churn flow transition boundary was shifted to higher gas velocity condition at a given liquid velocity, whereas the churn flow-to-annular flow transition boundary was shifted to lower gas velocity condition at a given liquid velocity. In the hydrophobic pipe, the inverted-churn flow regime was observed in the region where the churn flow regime was observed in the acrylic pipe, whereas the droplet flow regime was observed in the region where the annular flow regime was observed in the acrylic pipe. At high-gas flow rate condition, the mean void fraction in the hydrophobic pipe took relatively higher value to that in the acrylic pipe. (author)

  4. Detector for the liquid carried over in a gas

    International Nuclear Information System (INIS)

    Delisle, J.P.; Eperonnat, P.; Lions, N.

    1965-01-01

    This report describes an optical detector for the detection of a liquid carried over by a gas. The device is sensitive to a cumulated quantity of liquid equal to a few cubic millimetres and is capable of operating an alarm from a distance. The prototype was constructed and tested as detector for the oil leaking in the argon compressed by a diaphragm compressor. A patent for this apparatus under the number: P.V.954.703, has been deposited on 22.11.1963. (authors) [fr

  5. POLYP: an automatic device for drawing sequential samples of gas

    Energy Technology Data Exchange (ETDEWEB)

    Gaglione, P; Koechler, C; Stanchi, L

    1974-12-01

    Polyp is an automatic device consisting of electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. The other seven pumps will inflate sequentially the other bags. The instrument is powered by rechargeable batteries and realized with C-MUS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof.

  6. POLYP: an automatic device for drawing sequential samples of gas

    International Nuclear Information System (INIS)

    Gaglione, P.; Koechler, C.; Stanchi, L.

    1974-12-01

    POLYP is an automatic device consisting of an electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. Thereafter the other seven pumps will inflate sequentially the other bag. The instrument is powered by rechargeable batteries and realized with C-MOS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof

  7. Porous Metal Filters for Gas and Liquid Applications in the Nuclear Industry

    International Nuclear Information System (INIS)

    Kenneth, Rubow

    2009-01-01

    Sintered metal media are ideally suited for use in the most demanding industrial applications where long life is required and often other media are not cost-effective solution. As examples, filtration technology utilizing sintered metal media provides excellent performance in numerous liquid/solids and gas/solid separation applications found in the handling and processing of fluids containing radioactive materials. Many types of filter media, ranging from single use (disposable) to semi-permanent, are utilized today for separation of particulate matter. However, semi-permanent media are usually cleanable, either on or off-line, and are intended for sustainable, often multi-year, operating life in harsh environments. These harsh environments, which may involve corrosive fluids, high temperatures, high pressures or pressure spikes, often requiring continuous filtration service, are ideally suited for all-metal filtration systems employing semi-permanent sintered metal media. Sintered metal media, usually fabricated into tubular metal elements, have proven high particle removal efficiency and demonstrated reliability that uniquely afford excellent performance for demanding liquid/solids and gas/solids separation processes. The filter element and, in certain cases, the entire filter are weldable; therefore, the inherent sealing eliminates the need for potentially problematic seals. These media provide a positive barrier to ensure particulate removal to protect downstream equipment, for product separation, and/or to meet health, safety and environmental regulations. Typical applications for sintered metal media include: 1) gas and liquid filter systems used in various nuclear and radioactive waste processing applications, 2) an all-metal High Efficiency Particulate Air (HEPA) filter developed under Department of Energy (DOE) funding as an alternative to traditional HEPA filters fabricated with conventional glass fibers used on High Level Waste (HLW) tank ventilation

  8. Numerical modelling of inert gas bubble rising in liquid metal pool

    International Nuclear Information System (INIS)

    Pradeep, Arjun; Sharma, Anil Kumar; Ponraju, D.; Nashine, B K.

    2016-01-01

    Two-phase flow finds several applications in safe operation of Sodium-cooled Fast Reactor (SFR). Numerical modelling of bubble rise dynamics in liquid metal pool of SFR is essential for the evaluation of residence time and shape changes, which are of utmost importance for simulating associated heat and mass transfer processes involved in reactor safety. A numerical model has been developed based on OpenFOAM for the evaluation of two-dimensional inert gas bubble rise dynamics in stagnant liquid metal pool. The governing model equations are discretized and solved using the Volume of Fluid based solver available in OpenFOAM with appropriate initial and boundary conditions. The model has been validated with available numerical benchmark results for laminar transient two-phase flow. The model has been used to evaluate velocity and rise trajectory of argon gas bubble with different diameters through a pool of liquid sodium. (author)

  9. Pre-breakdown phenomena and discharges in a gas-liquid system

    Science.gov (United States)

    Tereshonok, D. V.; Babaeva, N. Yu; Naidis, G. V.; Panov, V. A.; Smirnov, B. M.; Son, E. E.

    2018-04-01

    In this paper, we investigate pre-breakdown and breakdown phenomena in gas-liquid systems. Cavitation void formation and breakdown in bubbles immersed in liquids are studied numerically, while complete breakdown of bubbled water is studied in experiments. It is shown that taking into account the dependence of water dielectric constant on electric field strength plays the same important role for cavitation void appearance under the action of electrostriction forces as the voltage rise time. It is also shown that the initial stage of breakdown in deformed bubbles immersed in liquid strongly depends on spatial orientation of the bubbles relative to the external electric field. The effect of immersed microbubbles, distributed in bulk water, on breakdown time and voltage is studied experimentally. At the breakdown voltage, the slow ‘thermal’ mechanism is changed by the fast ‘streamer-leader’ showing a decrease in breakdown time by two orders of magnitude by introducing microbubbles (0.1% of volumetric gas content) into the water. In addition, the plasma channel is found to pass between nearby microbubbles, exhibiting some ‘guidance’ effect.

  10. New perspective on gas-well liquid loading and unloading

    NARCIS (Netherlands)

    Veeken, C.A.M.; Belfroid, S.P.C.

    2010-01-01

    This paper discusses the multiphase flow mechanism responsible for gas-well liquid loading. It shows that the conventional idea of droplet flow reversal (Turner et al. (1969)) does not capture reality and that actual observations are better described by film flow reversal. This paper subsequently

  11. Entropy feature extraction on flow pattern of gas/liquid two-phase flow based on cross-section measurement

    International Nuclear Information System (INIS)

    Han, J; Dong, F; Xu, Y Y

    2009-01-01

    This paper introduces the fundamental of cross-section measurement system based on Electrical Resistance Tomography (ERT). The measured data of four flow regimes of the gas/liquid two-phase flow in horizontal pipe flow are obtained by an ERT system. For the measured data, five entropies are extracted to analyze the experimental data according to the different flow regimes, and the analysis method is examined and compared in three different perspectives. The results indicate that three different perspectives of entropy-based feature extraction are sensitive to the flow pattern transition in gas/liquid two-phase flow. By analyzing the results of three different perspectives with the changes of gas/liquid two-phase flow parameters, the dynamic structures of gas/liquid two-phase flow is obtained, and they also provide an efficient supplementary to reveal the flow pattern transition mechanism of gas/liquid two-phase flow. Comparison of the three different methods of feature extraction shows that the appropriate entropy should be used for the identification and prediction of flow regimes.

  12. Gas To Liquids Technology: A Futuristic View

    Energy Technology Data Exchange (ETDEWEB)

    El Shamy, A A [Egyptian General Petroleum Corporation, Opr. Development Depart., P.O No. 11742, Cairo (Egypt); Zayed, A M [Egyptian General Petroleum Corporation, Quality Control Department, P.O No. 11742, Cairo (Egypt)

    2004-07-01

    Worldwide efforts aimed to the formulation of environment friendly diesel fuels able to meet the advanced fuel specifications of the 21 st century and able to meet the global demand on diesel fuels. Synthetically derived gas to-liquid (GTL) diesel fuel promises to meet these challenges and spearhead the way to the future. This technology will produce almost zero sulfur, high cetane, low aromatic diesel and naphtha which will be sold regionally and internationally. GTL fuel is cleaner than any conventional fuel which will help the environment. It can be used in conventional diesel engines to give reductions in emission levels. Construction of such technology will reduce the gap between production and consumption by maximizing the gross profitability of natural gas.

  13. Gas To Liquids Technology: A Futuristic View

    International Nuclear Information System (INIS)

    El Shamy, A.A; Zayed, A.M

    2004-01-01

    Worldwide efforts aimed to the formulation of environment friendly diesel fuels able to meet the advanced fuel specifications of the 21 st century and able to meet the global demand on diesel fuels. Synthetically derived gas to-liquid (GTL) diesel fuel promises to meet these challenges and spearhead the way to the future. This technology will produce almost zero sulfur, high cetane, low aromatic diesel and naphtha which will be sold regionally and internationally. GTL fuel is cleaner than any conventional fuel which will help the environment. It can be used in conventional diesel engines to give reductions in emission levels. Construction of such technology will reduce the gap between production and consumption by maximizing the gross profitability of natural gas

  14. multiUQ: An intrusive uncertainty quantification tool for gas-liquid multiphase flows

    Science.gov (United States)

    Turnquist, Brian; Owkes, Mark

    2017-11-01

    Uncertainty quantification (UQ) can improve our understanding of the sensitivity of gas-liquid multiphase flows to variability about inflow conditions and fluid properties, creating a valuable tool for engineers. While non-intrusive UQ methods (e.g., Monte Carlo) are simple and robust, the cost associated with these techniques can render them unrealistic. In contrast, intrusive UQ techniques modify the governing equations by replacing deterministic variables with stochastic variables, adding complexity, but making UQ cost effective. Our numerical framework, called multiUQ, introduces an intrusive UQ approach for gas-liquid flows, leveraging a polynomial chaos expansion of the stochastic variables: density, momentum, pressure, viscosity, and surface tension. The gas-liquid interface is captured using a conservative level set approach, including a modified reinitialization equation which is robust and quadrature free. A least-squares method is leveraged to compute the stochastic interface normal and curvature needed in the continuum surface force method for surface tension. The solver is tested by applying uncertainty to one or two variables and verifying results against the Monte Carlo approach. NSF Grant #1511325.

  15. Simulation of the Two-Phase LiquidGas Flow through Ultrasonic Transceivers Application in Ultrasonic Tomography

    Directory of Open Access Journals (Sweden)

    Zulkarnay Zakaria

    2010-01-01

    Full Text Available In this paper, ultrasonic transmission mode tomography was used to visualize the two phase liquid/gas flow in a pipe/vessel. The sensing element consists of 8, 16 and 32 units ultrasonic transceivers were used to cover the pipe cross-section at different time. The motivation of this paper is to analyze the optimum numbers of transceivers which can give the best performance in providing better image of the two phase liquid/gas flow. This paper also details the development of the system including the ultrasonic transduction circuits, the electronic measurement circuits, the data acquisition system and the image reconstruction techniques. Ten conditions of liquid-gas flow have been simulated. The system was found capable of visualizing the internal characteristics and provides the concentration profile for the corresponding liquid and gas phases while the 32 transceivers has provided the best image for the ten conditions applied.

  16. Ionic liquids for nano- and microstructures preparation. Part 2: Application in synthesis.

    Science.gov (United States)

    Łuczak, Justyna; Paszkiewicz, Marta; Krukowska, Anna; Malankowska, Anna; Zaleska-Medynska, Adriana

    2016-01-01

    Ionic liquids (ILs) are widely applied to prepare metal nanoparticles and 3D semiconductor microparticles. Generally, they serve as a structuring agent or reaction medium (solvent), however it was also demonstrated that ILs can play a role of a co-solvent, metal precursor, reducing as well as surface modifying agent. The crucial role and possible types of interactions between ILs and growing particles have been presented in the Part 1 of this review paper. Part 2 of the paper gives a comprehensive overview of recent experimental studies dealing with application of ionic liquids for preparation of metal and semiconductor based nano- and microparticles. A wide spectrum of preparation routes using ionic liquids is presented, including precipitation, sol-gel technique, hydrothermal method, nanocasting and ray-mediated methods (microwave, ultrasound, UV-radiation and γ-radiation). It was found that ionic liquids formed of a 1-butyl-3-methylimidazolium [BMIM] combined with tetrafluoroborate [BF4], hexafluorophosphate [PF6], and bis(trifluoromethanesulfonyl)imide [Tf2N] are the most often used ILs in the synthesis of nano- and microparticles, due to their low melting temperature, low viscosity and good transportation properties. Nevertheless, examples of other IL classes with intrinsic nanoparticles stabilizing abilities such as phosphonium and ammonium derivatives are also presented. Experimental data revealed that structure of ILs (both anion and cation type) affects the size and shape of formed metal particles, and in some cases may even determine possibility of particles formation. The nature of the metal precursor determines its affinity to polar or nonpolar domains of ionic liquid, and therefore, the size of the nanoparticles depends on the size of these regions. Ability of ionic liquids to form varied extended interactions with particle precursor as well as other compounds presented in the reaction media (water, organic solvents etc.) provides nano- and

  17. The North American natural gas liquids markets are chaotic

    Energy Technology Data Exchange (ETDEWEB)

    Serletis, A.; Gogas, P. (Univ. of Calgary, Alberta (Canada). Dept. of Economics)

    1999-01-01

    In this paper the authors test for deterministic chaos (i.e., nonlinear deterministic processes which look random) in seven Mont Belview, Texas hydrocarbon markets, using monthly data from 1985:1 to 1996:12--the markets are those of ethane, propane, normal butane, iso-butane, naptha, crude oil, and natural gas. In doing so, they use the Lyapunov exponent estimator of Nychka, Ellner, Gallant, and McCaffrey. They conclude that there is evidence consistent with a chaotic nonlinear generation process in all five natural gas liquids markets.

  18. Two-phase gas bubble-liquid boundary layer flow along vertical and inclined surfaces

    International Nuclear Information System (INIS)

    Cheung, F.B.; Epstein, M.

    1985-01-01

    The behavior of a two-phase gas bubble-liquid boundary layer along vertical and inclined porous surfaces with uniform gas injection is investigated experimentally and analytically. Using argon gas and water as the working fluids, a photographical study of the two-phase boundary layer flow has been performed for various angles of inclination ranging from 45 0 to 135 0 and gas injection rates ranging from 0.01 to 0.1 m/s. An integral method has been employed to solve the system of equations governing the two-phase motion. The effects of the gas injection rate and the angle of inclination on the growth of the boundary layer have been determined. The predicted boundary layer thickness is found to be in good agreement with the experimental results. The calculated axial liquid velocity and the void fraction in the two-phase region are also presented along with the observed flow behavior

  19. INTERACTION OF LIQUID FLAT SCREENS WITH GAS FLOW RESTRICTED BY CHANNEL WALLS

    Directory of Open Access Journals (Sweden)

    S. T. Aksentiev

    2005-01-01

    Full Text Available The paper gives description of physical pattern of liquid screen interaction that are injected from the internal walls of a rectangular channel with gas flow. Criterion dependences for determination of intersection coordinates of external boundaries with longitudinal channel axis and factor of liquid screen head resistance.

  20. Enhanced Gas Separation through Nanoconfined Ionic Liquid in Laminated MoS2 Membrane.

    Science.gov (United States)

    Chen, Danke; Ying, Wen; Guo, Yi; Ying, Yulong; Peng, Xinsheng

    2017-12-20

    Two-dimensional (2D) materials-based membranes show great potential for gas separation. Herein an ionic liquid, 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][BF 4 ]), was confined in the 2D channels of MoS 2 -laminated membranes via an infiltration process. Compared with the corresponding bulk [BMIM][BF 4 ], nanoconfined [BMIM][BF 4 ] shows an obvious incremental increase in freezing point and a shift of vibration bands. The resulting MoS 2 -supported ionic liquid membrane (MoS 2 SILM) exhibits excellent CO 2 separation performance with high CO 2 permeance (47.88 GPU) and superb selectivity for CO 2 /N 2 (131.42), CO 2 /CH 4 (43.52), and CO 2 /H 2 (14.95), which is much better than that of neat [BMIM][BF 4 ] and [BMIM][BF 4 ]-based membranes. The outstanding performance of MoS 2 SILMs is attributed to the nanoconfined [BMIM][BF 4 ], which enables fast transport of CO 2 . Long-term operation also reveals the durability and stability of the prepared MoS 2 SILMs. The method of confining ILs in the 2D nanochannels of 2D materials may pave a new way for CO 2 capture and separation.

  1. Liquid water transport mechanism in the gas diffusion layer

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, P.; Wu, C.W. [State Key Laboratory of Structure Analysis for Industrial Equipment, Department of Engineering Mechanics, Faculty of Vehicle Engineering and Mechanics, Dalian University of Technology, Dalian 116024 (China)

    2010-03-01

    We developed an equivalent capillary model of a microscale fiber-fence structure to study the microscale evolution and transport of liquid in a porous media and to reveal the basic principles of water transport in gas diffusion layer (GDL). Analytical solutions using the model show that a positive hydraulic pressure is needed to drive the liquid water to penetrate through the porous GDL even consisting of the hydrophilic fibers. Several possible contributions for the water configuration, such as capillary pressure, gravity, vapor condensation, wettability and microstructures of the GDL, are discussed using the lattice Boltzmann method (LBM). It is found that the distribution manners of the fibers and the spatial mixed-wettability in the GDL also play an important role in the transport of liquid water. (author)

  2. Preparation of environmental analyses for synfuel and unconventional gas technologies

    Energy Technology Data Exchange (ETDEWEB)

    Reed, R.M. (ed.)

    1982-09-01

    Government agencies that offer financial incentives to stimulate the commercialization of synfuel and unconventional gas technologies usually require an analysis of environmental impacts resulting from proposed projects. This report reviews potentially significant environmental issues associated with a selection of these technologies and presents guidance for developing information and preparing analyses to address these issues. The technologies considered are western oil shale, tar sand, coal liquefaction and gasification, peat, unconventional gas (western tight gas sands, eastern Devonian gas shales, methane from coal seams, and methane from geopressured aquifers), and fuel ethanol. Potentially significant issues are discussed under the general categories of land use, air quality, water use, water quality, biota, solid waste disposal, socioeconomics, and health and safety. The guidance provided in this report can be applied to preparation and/or review of proposals, environmental reports, environmental assessments, environmental impact statements, and other types of environmental analyses. The amount of detail required for any issue discussed must, by necessity, be determined on a case-by-case basis.

  3. PREDICTION OF GAS HOLD-UP IN A COMBINED LOOP AIR LIFT FLUIDIZED BED REACTOR USING NEWTONIAN AND NON-NEWTONIAN LIQUIDS

    Directory of Open Access Journals (Sweden)

    Sivakumar Venkatachalam

    2011-09-01

    Full Text Available Many experiments have been conducted to study the hydrodynamic characteristics of column reactors and loop reactors. In this present work, a novel combined loop airlift fluidized bed reactor was developed to study the effect of superficial gas and liquid velocities, particle diameter, fluid properties on gas holdup by using Newtonian and non-Newtonian liquids. Compressed air was used as gas phase. Water, 5% n-butanol, various concentrations of glycerol (60 and 80% were used as Newtonian liquids, and different concentrations of carboxy methyl cellulose aqueous solutions (0.25, 0.6 and 1.0% were used as non-Newtonian liquids. Different sizes of spheres, Bearl saddles and Raschig rings were used as solid phases. From the experimental results, it was found that the increase in superficial gas velocity increases the gas holdup, but it decreases with increase in superficial liquid velocity and viscosity of liquids. Based on the experimental results a correlation was developed to predict the gas hold-up for Newtonian and non-Newtonian liquids for a wide range of operating conditions at a homogeneous flow regime where the superficial gas velocity is approximately less than 5 cm/s

  4. Characterising gas behaviour during gas-liquid co-current up-flow in packed beds using magnetic resonance imaging

    OpenAIRE

    Collins, James HP; Sederman, Andrew John; Gladden, Lynn Faith; Afeworki, Mobae; Kushnerick, J Douglas; Thomann, Hans

    2016-01-01

    Magnetic resonance (MR) imaging techniques have been used to study gas phase dynamics during co-current up-flow in a column of inner diameter 43 mm, packed with spherical non-porous elements of diameters of 1.8, 3 and 5 mm. MR measurements of gas hold-up, bubble-size distribution, and bubble-rise velocities were made as a function of flow rate and packing size. Gas and liquid flow rates were studied in the range of 20–250 cm3 s−1 and 0–200 cm3 min−1, respectively. The gas hold-up within the b...

  5. Automatically varying the composition of a mixed refrigerant solution for single mixed refrigerant LNG (liquefied natural gas) process at changing working conditions

    International Nuclear Information System (INIS)

    Xu, Xiongwen; Liu, Jinping; Cao, Le; Pang, Weiqiang

    2014-01-01

    The SMR (single mixed refrigerant) process is widely used in the small- and medium-scale liquefaction of NG (natural gas). Operating the MR (mixed-refrigerant) process outside of the design specifications is difficult but essential to save energy. Nevertheless, it is difficult to realize because the process needs to alter the working refrigerant composition. To address this challenge, this study investigated the performance diagnosis mechanism for SMR process. A control strategy was then proposed to control the changes in working refrigerant composition under different working conditions. This strategy separates the working refrigerant flow in the SMR process into three flows through two phase separators before it flows into the cold box. The first liquid flow is rich in the high-temperature component (isopentane). The second liquid flow is rich in the middle-temperature components (ethylene and propane), and the gas flow is rich in the low-temperature components (nitrogen and methane). By adjusting the flow rates, it is easy to decouple the control variables and automate the system. Finally, this approach was validated by process simulation and shown to be highly adaptive and exergy efficient in response to changing working conditions. - Highlights: • The performance diagnosis mechanism of SMR LNG process is studied. • A measure to automatically change the operation composition as per the working conditions is proposed for SMR process. • SMR process simulation is performed to verify the validity of the control solution. • The control solution notably improves the energy efficiency of SMR process at changing working condition

  6. Gas-liquid mass transfer in a cross-flow hollow fiber module : Analytical model and experimental validation

    NARCIS (Netherlands)

    Dindore, V. Y.; Versteeg, G. F.

    2005-01-01

    The cross-flow operation of hollow fiber membrane contactors offers many advantages and is preferred over the parallel-flow contactors for gas-liquid mass transfer operations. However, the analysis of such a cross-flow membrane gas-liquid contactor is complicated due to the change in concentrations

  7. Experimental Study of gas-liquid two-phase flow affected by wall surface wettability

    International Nuclear Information System (INIS)

    Takamasa, T.; Hazuku, T.; Hibiki, T.

    2008-01-01

    To evaluate the effect of wall surface wettability on the characteristics of upward gas-liquid two-phase flow in a vertical pipe, an experimental study was performed using three test pipes: an acrylic pipe, a hydrophilic pipe and a hydrophobic pipe. Basic flow characteristics such as flow patterns, pressure drop and void fraction were measured in these three pipes. In the hydrophilic pipe, a slug to churn flow transition boundary was shifted to a higher gas velocity at a given liquid velocity, whereas a churn to annular flow transition boundary was shifted to a lower gas velocity at a given liquid velocity. In the hydrophobic pipe, an inverted-churn flow regime was observed in the region where the churn flow regime was observed in the acrylic pipe, while a droplet flow regime was observed in the region where an annular flow regime was observed in the acrylic pipe. At a high gas flow rate, the mean void fraction in the hydrophobic pipe was higher than in the acrylic pipe. The effect of surface wettability on frictional pressure loss was confirmed to be insignificant under the present experimental conditions

  8. Molten salt hazardous waste disposal process utilizing gas/liquid contact for salt recovery

    International Nuclear Information System (INIS)

    Grantham, L.F.; McKenzie, D.E.

    1984-01-01

    The products of a molten salt combustion of hazardous wastes are converted into a cooled gas, which can be filtered to remove hazardous particulate material, and a dry flowable mixture of salts, which can be recycled for use in the molten salt combustion, by means of gas/liquid contact between the gaseous products of combustion of the hazardous waste and a solution produced by quenching the spent melt from such molten salt combustion. The process results in maximizing the proportion of useful materials recovered from the molten salt combustion and minimizing the volume of material which must be discarded. In a preferred embodiment a spray dryer treatment is used to achieve the desired gas/liquid contact

  9. Thermal transistor utilizing gas-liquid transition

    KAUST Repository

    Komatsu, Teruhisa S.

    2011-01-25

    We propose a simple thermal transistor, a device to control heat current. In order to effectively change the current, we utilize the gas-liquid transition of the heat-conducting medium (fluid) because the gas region can act as a good thermal insulator. The three terminals of the transistor are located at both ends and the center of the system, and are put into contact with distinct heat baths. The key idea is a special arrangement of the three terminals. The temperature at one end (the gate temperature) is used as an input signal to control the heat current between the center (source, hot) and another end (drain, cold). Simulating the nanoscale systems of this transistor, control of heat current is demonstrated. The heat current is effectively cut off when the gate temperature is cold and it flows normally when it is hot. By using an extended version of this transistor, we also simulate a primitive application for an inverter. © 2011 American Physical Society.

  10. Software of the BESM-6 computer for automatic image processing from liquid-hydrogen bubble chambers

    International Nuclear Information System (INIS)

    Grebenikov, E.A.; Kiosa, M.N.; Kobzarev, K.K.; Kuznetsova, N.A.; Mironov, S.V.; Nasonova, L.P.

    1978-01-01

    A set of programs, which is used in ''road guidance'' mode on the BESM-6 computer to process picture information taken in liquid hydrogen bubble chambers is discussed. This mode allows the system to process data from an automatic scanner (AS) taking into account the results of manual scanning. The system hardware includes: an automatic scanner, an M-6000 mini-controller and a BESM-6 computer. Software is functionally divided into the following units: computation of event mask parameters and generation . of data files controlling the AS; front-end processing of data coming from the AS; filtering of track data; simulation of AS operation and gauging of the AS reference system. To speed up the overall performance, programs which receive and decode data, coming from the AS via the M-6000 controller and the data link to the BESM-6 computer, are written in machine language

  11. Variability of matrix effects in liquid and gas chromatography - mass spectrometry analysis of pesticide residues after QuEChERS sample preparation of different food crops

    Science.gov (United States)

    Gas and liquid chromatography (GC and LC) coupled to sophisticated mass spectrometry (MS) instruments are among the most powerful analytical tools currently available to monitor pesticide residues in food, among other applications. However, both GC-MS and LC-MS are susceptible to matrix effects whi...

  12. Visual observations of individual particle behaviour in gas and liquid fluidized beds

    NARCIS (Netherlands)

    Hartholt, G.P; Hoffmann, A.C; Janssen, L.P.B.M.

    The behaviour of the individual particles in dense gas and liquid fluidized beds and the behaviour of the jetsam particles in gas fluidized beds containing binary mixtures of different density group B powders has been observed. These visualizations have been made by means of an optical probe fitted

  13. A mechanistic model of heat transfer for gas-liquid flow in vertical wellbore annuli.

    Science.gov (United States)

    Yin, Bang-Tang; Li, Xiang-Fang; Liu, Gang

    2018-01-01

    The most prominent aspect of multiphase flow is the variation in the physical distribution of the phases in the flow conduit known as the flow pattern. Several different flow patterns can exist under different flow conditions which have significant effects on liquid holdup, pressure gradient and heat transfer. Gas-liquid two-phase flow in an annulus can be found in a variety of practical situations. In high rate oil and gas production, it may be beneficial to flow fluids vertically through the annulus configuration between well tubing and casing. The flow patterns in annuli are different from pipe flow. There are both casing and tubing liquid films in slug flow and annular flow in the annulus. Multiphase heat transfer depends on the hydrodynamic behavior of the flow. There are very limited research results that can be found in the open literature for multiphase heat transfer in wellbore annuli. A mechanistic model of multiphase heat transfer is developed for different flow patterns of upward gas-liquid flow in vertical annuli. The required local flow parameters are predicted by use of the hydraulic model of steady-state multiphase flow in wellbore annuli recently developed by Yin et al. The modified heat-transfer model for single gas or liquid flow is verified by comparison with Manabe's experimental results. For different flow patterns, it is compared with modified unified Zhang et al. model based on representative diameters.

  14. Degradation of gas-liquid gliding arc discharge on Acid Orange II

    International Nuclear Information System (INIS)

    Yan, J.H.; Liu, Y.N.; Bo, Zh.; Li, X.D.; Cen, K.F.

    2008-01-01

    The effects of pH value, initial concentration of dye solution and temperature on the degradation efficiency of Acid Orange II (AO7) using gas-liquid gliding arc discharge were investigated. The influences of pH value and temperature on degradation efficiency were not apparent. Increasing initial solution concentration caused the decrease of degradation rate and the increase of absolute degradation quantity. Considering energy efficiency and absolute degradation quantity, the gas-liquid gliding arc discharge is fit for treating high concentration organic wastewater. A possible mineralization pathway was proposed through the analysis of intermediate products detected by gas chromatograph coupled with mass spectrophotometer (GC-MS) and ion chromatograph (IC). Hydroxyl radicals reacted with the azo linkage-bearing carbon of a hydroxy-substituted ring, leading to the cleavage of -C-N- and degradation of AO7. The solution biodegradability was significantly improved (BOD 5 /COD from 0.02 to 0.43). The toxicity of intermediate products was lower than that of the initial Acid Orange II

  15. Supercooled liquid vapour pressures and related thermodynamic properties of polycyclic aromatic hydrocarbons determined by gas chromatography

    NARCIS (Netherlands)

    Haftka, J.J.H.; Parsons, J.R.; Govers, H.A.J.

    2006-01-01

    A gas chromatographic method using Kovats retention indices has been applied to determine the liquid vapour pressure (P-i), enthalpy of vaporization (Delta H-i) and difference in heat capacity between gas and liquid phase (Delta C-i) for a group of polycyclic aromatic hydrocarbons (PAHs). This group

  16. A New Approach for Accurate Prediction of Liquid Loading of Directional Gas Wells in Transition Flow or Turbulent Flow

    Directory of Open Access Journals (Sweden)

    Ruiqing Ming

    2017-01-01

    Full Text Available Current common models for calculating continuous liquid-carrying critical gas velocity are established based on vertical wells and laminar flow without considering the influence of deviation angle and Reynolds number on liquid-carrying. With the increase of the directional well in transition flow or turbulent flow, the current common models cannot accurately predict the critical gas velocity of these wells. So we built a new model to predict continuous liquid-carrying critical gas velocity for directional well in transition flow or turbulent flow. It is shown from sensitivity analysis that the correction coefficient is mainly influenced by Reynolds number and deviation angle. With the increase of Reynolds number, the critical liquid-carrying gas velocity increases first and then decreases. And with the increase of deviation angle, the critical liquid-carrying gas velocity gradually decreases. It is indicated from the case calculation analysis that the calculation error of this new model is less than 10%, where accuracy is much higher than those of current common models. It is demonstrated that the continuous liquid-carrying critical gas velocity of directional well in transition flow or turbulent flow can be predicted accurately by using this new model.

  17. Boiling, condensation, and gas-liquid flow

    International Nuclear Information System (INIS)

    Whalley, P.B.

    1987-01-01

    Heat transfer phenomena involving boiling and condensation are an important aspect of engineering in the power and process industries. This book, aimed at advanced first-degree and graduate students in mechanical and chemical engineering, deals with these phenomena in detail. The first part of the book describes gas-liquid two-phase flow, as a necessary preliminary to the later discussion of heat transfer and change of phase. A detailed section on calculation methods shows how theory can be put to practical use, and there are also descriptions of some of the equipment and plant used in the process and power industries

  18. Preparation of copper and silicon/copper powders by a gas ...

    Indian Academy of Sciences (India)

    Pure and silicon-coated metal copper nano to submicron-sized powders were prepared by gas evaporation and condensation. This powder was synthesized by using an industrial electron accelerator, ELV-6, with Ar as the carrier gas. Vapour from the liquefied metal surface was transferred to the cold zone by the carrier ...

  19. Preparation and transport properties of novel lithium ionic liquids

    International Nuclear Information System (INIS)

    Shobukawa, Hitoshi; Tokuda, Hiroyuki; Tabata, Sei-Ichiro; Watanabe, Masayoshi

    2004-01-01

    Novel lithium salts of borates having two electron-withdrawing groups (either 1,1,1,3,3,3-hexafluoro-2-propoxy or pentafluorophenoxy group) and two methoxy-oligo(ethylene oxide) groups (number of repeating unit: n = 3, 4, 7.2) were prepared by successive substitution-reactions from LiBH 4 . The obtained lithium salts were clear and colorless liquids at room temperature. The density, thermal property, viscosity, and ionic conductivity were measured for the lithium ionic liquids. The pulsed-gradient spin-echo NMR (PGSE-NMR) method was used to independently determine self-diffusion coefficients of the lithium cation ( 7 Li NMR) and the anion ( 19 F NMR) in the bulk. The ionic conductivity of the new lithium salts was 10 -5 to 10 -4 S cm -1 at 30 deg. C, which was lower than that of typical ionic liquids by two orders of magnitude. However, the degree of self-dissociation of the lithium ionic liquids; the ratio of the molar conductivity determined by the complex impedance method to that calculated from the self-diffusion coefficients and the Nernst-Einstein equation, ranged from 0.1 to 0.4, which are comparable values to those of a highly dissociable salt in an aprotic polar solvent and of typical ionic liquids. The main reason for the meager conductivity was high viscosities of the lithium ionic liquids. It should be noted that the lithium ionic liquids have self-dissociation ability and conduct the ions in the absence of organic solvents

  20. Purification of gas and liquid media by metal-ceramic SHS-filters

    OpenAIRE

    Geyneman, A. A.; Goncharov, V. D.; Novoselov, A. L.; Shchetinkina, N. Yu.

    2007-01-01

    Industrial samples of fine filters of gas and liquid media from mechanical microparticles have been developed. Porous permeable cermets obtained by self-propagating high-temperature synthesis are the basis of filters

  1. Langmuir-Blodgett films prepared from pre-formed cholestanic liquid-crystalline polymers

    Energy Technology Data Exchange (ETDEWEB)

    Tundo, P.; Hodge, P.; Valli, L.; Davis, F. (Venice Univ. (Italy). Dip. di Scienze Ambientali Lecce Univ. (Italy). Dip. di Scienza dei Materiali Manchester Univ. (United Kingdom). Dep. of Chemistry)

    1992-01-01

    A series of alternating copolymers of maleic anhydride and a-olefins functionalized through different alkyl chains with cholestanic groups were synthetised and derivatives prepared by reactions of the anhydride residues with methanol, water, dimethylamine and morpholine, respectively. The same starting functionalized a-olefins were used to prepare other suitable compounds in order to correlate the features of the liquid-crystalline behaviour of the mesogenic cholestanic group with the stability of the forthcoming polymeric or not polymeric Langmuir-Blodgett (LB) films. For some copolymers surface pressure against area per molecule isotherms are reported. In some multilayer (LB) films, the spacings between the layers were determined by the detection of BRAGG peaks by X-ray diffraction. The (LB) films of these polymers are closed packed, owing to either the polymeric skeleton or liquid-crystalline interaction.

  2. Isotope Fractionation in Methane Reactions Studied by Gas Chromatography and Liquid Scintillation

    DEFF Research Database (Denmark)

    Andersen, Bertel Lohmann; Bidoglio, G.; Leip, A.

    1997-01-01

    Determination of C-14-marked methane by gas chromatography and liquid scintillation counting is shown to be useful in studies of isotope effects. Data on the specific activity is used to separate the contributions of (CH4)-C-14, and (CH4)-C-12 to the gas-chromatographic peak area. As an application...

  3. Hydrodynamic characteristics of a two-phase gas-liquid flow upward through a fixed bed of spherical particles

    Directory of Open Access Journals (Sweden)

    VELIZAR D. STANKOVIC

    2001-01-01

    Full Text Available The influence of an electrochemically generated gas phase on the hydrodynamic characteristics of a three-phase system has been examined. The two-phase fluid, (gas-liquid, in which the liquid phase is the continuous one, flows through a packed bed with glass spheres. The influence of the liquid velocity was examined, as well as the gas velocity and particle diameter on the pressure drop through the fixed bed. It was found that with increasing liquid velocity (wl = 0.0162–0.03 m/s, the relative pressure drop decreases through the fixed bed. With increasing current density, the pressure drop increases, since greater gas quantities stay behind in the fixed bed. Besides, it was found that with decreasing diameter of the glass particles, the relative pressure drop also decreases. The relationship betweeen the experimentally obtained friction factor and the Reynolds number was established.

  4. The influence of liquid-gas velocity ratio on the noise of the cooling tower

    Science.gov (United States)

    Yang, Bin; Liu, Xuanzuo; Chen, Chi; Zhao, Zhouli; Song, Jinchun

    2018-05-01

    The noise from the cooling tower has a great influence on psychological performance of human beings. The cooling tower noise mainly consists of fan noise, falling water noise and mechanical noise. This thesis used DES turbulence model with FH-W model to simulate the flow and sound pressure field in cooling tower based on CFD software FLUENT and analyzed the influence of different kinds noise, which affected by diverse factors, on the cooling tower noise. It can be concluded that the addition of cooling water can reduce the turbulence and vortex noise of the rotor fluid field in the cooling tower at some extent, but increase the impact noise of the liquid-gas two phase. In general, the cooling tower noise decreases with the velocity ratio of liquid to gas increasing, and reaches the lowest when the velocity ratio of liquid to gas is close to l.

  5. Unreviewed safety question evaluation of 100 K West fuel canister gas and liquid sampling

    International Nuclear Information System (INIS)

    Alwardt, L.D.

    1995-01-01

    The purpose of this report is to provide the basis for answers to an Unreviewed Safety Question (USQ) safety evaluation for the gas and liquid sampling activities associated with the fuel characterization program at the 100 K West (KW) fuel storage basin. The scope of this safety evaluation is limited to the movement of canisters between the main storage basin, weasel pit, and south loadout pit transfer channel (also known as the decapping station); gas and liquid sampling of fuel canisters in the weasel pit; mobile laboratory preliminary sample analysis in or near the 105 KW basin building; and the placement of sample containers in an approved shipping container. It was concluded that the activities and potential accident consequences associated with the gas and liquid sampling of 100 KW fuel canisters are bounded by the current safety basis documents and do not constitute an Unreviewed Safety Question

  6. The use of a low-cost gas-liquid flow meter to monitor severe slugging

    DEFF Research Database (Denmark)

    Andreussi, Paolo; Bonizzi, Marco; Ciandri, Paolo

    2017-01-01

    A very simple, low-cost gas-liquid flow meter that only employs conventional field instrumentation has been used to monitor severe slugging occurring at the exit of a vertical pipe. This meter was originally developed for conventional oil field applications [1] and is based on the readings...... method to monitor severe slugging by means of low cost instrumentation, in particular, by replacing a cumbersome instrument such as a gamma-densitometer with a differential pressure transmitter. In field operation, the multiphase orifice used in these experiments can be replaced by a calibrated control...... of a multiphase orifice and the pressure drops of the gas-liquid mixture flowing in a vertical section of the pipe. Liquid and gas flow rates have been determined by means of semi-empirical equations developed for the specific set of flow parameters (geometry, flow rates, physical properties) adopted in a series...

  7. Progress report on a fully automatic Gas Tungsten Arc Welding (GTAW) system development

    Energy Technology Data Exchange (ETDEWEB)

    Daumeyer, G.J. III

    1994-12-01

    A plan to develop a fully automatic gas tungsten arc welding (GTAW) system that will utilize a vision-sensing computer (which will provide in-process feedback control) is presently in work. Evaluations of different technological aspects and system design requirements continue. This report summaries major activities in the plan`s successful progress. The technological feasibility of producing the fully automated GTAW system has been proven. The goal of this process development project is to provide a production-ready system within the shortest reasonable time frame.

  8. Characterization of liquid entrainment in the AP1000 automatic depressurization system from APEX tests

    International Nuclear Information System (INIS)

    Richard F Wright; Terry L Schulz; Jose N Reyes; John Groome

    2005-01-01

    Full text of publication follows: The AP1000 is a 1000 MWe advanced nuclear power plant that uses passive safety features to enhance plant safety and to provide significant and measurable improvements in plant simplification, reliability, investment protection and plant costs. The AP1000 relies heavily on the 600 MWe AP600 which received design certification in 1999. A critical part of the AP600 design certification process involved the testing of the passive safety systems. A one-fourth height, one-fourth pressure test facility, APEX-600, was constructed at the Oregon State University to study design basis events, and to provide a body of data to be used to validate the computer models used to analyze the AP600. This facility was extensively modified to reflect the design changes for AP1000 including higher power in the electrically heated rods representing the reactor core, and changes in the size of the pressurizer, core makeup tanks and automatic depressurization system. The APEX-1000 test facility was used to perform design basis accident simulations and separate effects tests to support the AP1000 design certification process. In the event of a LOCA, the AP1000 passive core cooling system provides sources of core makeup water along with an automatic depressurization system (ADS) consisting of several stages of valves which reduce the reactor coolant system pressure in a controlled manner. The final stage of this system, ADS-4, consists of four large valves that open off the hot legs, reducing the pressure to allow gravity injection from the in-containment refueling water storage tank (IRWST) and eventually the containment sump. The 67% increase in power from AP600 to AP1000 results in proportionally larger steam velocities exiting the core. Higher steam velocities could increases the potential for significant liquid entrainment out the ADS-4 lines, affecting the liquid inventory in the reactor. Tests were performed in APEX-1000 to characterize the two

  9. Coupling compositional liquid gas Darcy and free gas flows at porous and free-flow domains interface

    Energy Technology Data Exchange (ETDEWEB)

    Masson, R., E-mail: roland.masson@unice.fr [LJAD, University Nice Sophia Antipolis, CNRS UMR 7351 (France); Team COFFEE INRIA Sophia Antipolis Méditerranée (France); Trenty, L., E-mail: laurent.trenty@andra.fr [Andra, Chatenay Malabry (France); Zhang, Y., E-mail: yumeng.zhang@unice.fr [LJAD, University Nice Sophia Antipolis, CNRS UMR 7351 (France); Team COFFEE INRIA Sophia Antipolis Méditerranée (France)

    2016-09-15

    This paper proposes an efficient splitting algorithm to solve coupled liquid gas Darcy and free gas flows at the interface between a porous medium and a free-flow domain. This model is compared to the reduced model introduced in [6] using a 1D approximation of the gas free flow. For that purpose, the gas molar fraction diffusive flux at the interface in the free-flow domain is approximated by a two point flux approximation based on a low-frequency diagonal approximation of a Steklov–Poincaré type operator. The splitting algorithm and the reduced model are applied in particular to the modelling of the mass exchanges at the interface between the storage and the ventilation galleries in radioactive waste deposits.

  10. AUTOMATIC CONTROL SYSTEM FOR REGULATED HIGH TEMPERATURE MAIN COMBUSTION CHAMBER OF MANEUVERABLE AIRCRAFT MULTIMODE GAS TURBINE ENGINE

    Directory of Open Access Journals (Sweden)

    T. V. Gras’Ko

    2014-01-01

    Full Text Available The paper describes choosing and substantiating the control laws, forming the appearance the automatic control system for regulated high temperature main combustion chamber of maneuverable aircraft multimode gas turbine engine aimed at sustainable and effective functioning of main combustion chamber within a broad operation range.

  11. An Efficient Protocol for Preparation of Gallic Acid from Terminalia bellirica (Gaertn.) Roxb by Combination of Macroporous Resin and Preparative High-Performance Liquid Chromatography.

    Science.gov (United States)

    Zou, Denglang; Chen, Tao; Chen, Chen; Li, Hongmei; Liu, Yongling; Li, Yulin

    2016-08-01

    In this article, macroporous resin column chromatography and preparative high-performance liquid chromatography were applied for preparation of gallic acid from Terminalia bellirica (Gaertn.) Roxb. In the first step, six kinds of resins were investigated by adsorption and desorption tests and AB-8 macroporous resin was selected for the enrichment of gallic acid. As a result, 20 g of gallic acid at a purity of 71% could be separated from 100 g of crude extract in which the content of gallic acid was 16.7% and the recovery of gallic acid reached 85.0%. In the second step, preparative high-performance liquid chromatography was selected to purify gallic acid. As a result, 640 mg of gallic acid at a purity of 99.1% was obtained from 1 g of sample in 35 min. The results demonstrated that macroporous resin coupled with preparative high-performance liquid chromatography was suitable for preparation of gallic acid from T. bellirica (Gaertn.) Roxb. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Heat transfer characteristics of liquid-gas Taylor flows incorporating microencapsulated phase change materials

    International Nuclear Information System (INIS)

    Howard, J A; Walsh, P A

    2014-01-01

    This paper presents an investigation on the heat transfer characteristics associated with liquid-gas Taylor flows in mini channels incorporating microencapsulated phase change materials (MPCM). Taylor flows have been shown to result in heat transfer enhancements due to the fluid recirculation experienced within liquid slugs which is attributable to the alternating liquid slug and gas bubble flow structure. Microencapsulated phase change materials (MPCM) also offer significant potential with increased thermal capacity due to the latent heat required to cause phase change. The primary aim of this work was to examine the overall heat transfer potential associated with combining these two novel liquid cooling technologies. By investigating the local heat transfer characteristics, the augmentation/degradation over single phase liquid cooling was quantified while examining the effects of dimensionless variables, including Reynolds number, liquid slug length and gas void fraction. An experimental test facility was developed which had a heated test section and allowed MPCM-air Taylor flows to be subjected to a constant heat flux boundary condition. Infrared thermography was used to record high resolution experimental wall temperature measurements and determine local heat transfer coefficients from the thermal entrance point. 30.2% mass particle concentration of the MPCM suspension fluid was examined as it provided the maximum latent heat for absorption. Results demonstrate a significant reduction in experimental wall temperatures associated with MPCM-air Taylor flows when compared with the Graetz solution for conventional single phase coolants. Total enhancement in the thermally developed region is observed to be a combination of the individual contributions due to recirculation within the liquid slugs and also absorption of latent heat. Overall, the study highlights the potential heat transfer enhancements that are attainable within heat exchange devices employing MPCM

  13. Miniaturized Planar Room Temperature Ionic Liquid Electrochemical Gas Sensor for Rapid Multiple Gas Pollutants Monitoring.

    Science.gov (United States)

    Wan, Hao; Yin, Heyu; Lin, Lu; Zeng, Xiangqun; Mason, Andrew J

    2018-02-01

    The growing impact of airborne pollutants and explosive gases on human health and occupational safety has escalated the demand of sensors to monitor hazardous gases. This paper presents a new miniaturized planar electrochemical gas sensor for rapid measurement of multiple gaseous hazards. The gas sensor features a porous polytetrafluoroethylene substrate that enables fast gas diffusion and room temperature ionic liquid as the electrolyte. Metal sputtering was utilized for platinum electrodes fabrication to enhance adhesion between the electrodes and the substrate. Together with carefully selected electrochemical methods, the miniaturized gas sensor is capable of measuring multiple gases including oxygen, methane, ozone and sulfur dioxide that are important to human health and safety. Compared to its manually-assembled Clark-cell predecessor, this sensor provides better sensitivity, linearity and repeatability, as validated for oxygen monitoring. With solid performance, fast response and miniaturized size, this sensor is promising for deployment in wearable devices for real-time point-of-exposure gas pollutant monitoring.

  14. An investigation on near wall transport characteristics in an adiabatic upward gas-liquid two-phase slug flow

    Science.gov (United States)

    Zheng, Donghong; Che, Defu

    2007-08-01

    The near-wall transport characteristics, inclusive of mass transfer coefficient and wall shear stress, which have a great effect on gas-liquid two-phase flow induced internal corrosion of low alloy pipelines in vertical upward oil and gas mixing transport, have been both mechanistically and experimentally investigated in this paper. Based on the analyses on the hydrodynamic characteristics of an upward slug unit, the mass transfer in the near wall can be divided into four zones, Taylor bubble nose zone, falling liquid film zone, Taylor bubble wake zone and the remaining liquid slug zone; the wall shear stress can be divided into two zones, the positive wall shear stress zone associated with the falling liquid film and the negative wall shear stress zone associated with the liquid slug. Based on the conventional mass transfer and wall shear stress characteristics formulas of single phase liquid full-pipe turbulent flow, corrected normalized mass transfer coefficient formula and wall shear stress formula are proposed. The calculated results are in good agreement with the experimental data. The shear stress and the mass transfer coefficient in the near wall zone are increased with the increase of superficial gas velocity and decreased with the increase of superficial liquid velocity. The mass transfer coefficients in the falling liquid film zone and the wake zone of leading Taylor bubble are lager than those in the Taylor bubble nose zone and the remaining liquid slug zone, and the wall shear stress associated falling liquid film is larger than that associated the liquid slug. The mass transfer coefficient is within 10-3 m/s, and the wall shear stress below 103 Pa. It can be concluded that the alternate wall shear stress due to upward gas-liquid slug flow is considered to be the major cause of the corrosion production film fatigue cracking.

  15. Preparation and Characterization of Silver Liquid Thin Films for Magnetic Fluid Deformable Mirror

    Directory of Open Access Journals (Sweden)

    Lianchao Zhang

    2015-01-01

    Full Text Available Silver liquid thin film, formed by silver nanoparticles stacking and spreading on the surface of the liquid, is one of the important parts of magnetic fluid deformable mirror. First, silver nanoparticles were prepared by liquid phase chemical reduction method using sodium citrate as reducing agent and stabilizer and silver nitrate as precursor. Characterization of silver nanoparticles was studied using X-ray diffractometer, UV-vis spectrophotometer, and transmission electron microscope (TEM. The results showed that silver nanoparticles are spherical and have a good monodispersity. Additionally, the effect of the reaction conditions on the particle size of silver is obvious. And then silver liquid thin films were prepared by oil-water two-phase interface technology using as-synthesized silver nanoparticles. Properties of the film were investigated using different technology. The results showed that the film has good reflectivity and the particle size has a great influence on the reflectivity of the films. SEM photos showed that the liquid film is composed of multilayer silver nanoparticles. In addition, stability of the film was studied. The results showed that after being stored for 8 days under natural conditions, the gloss and reflectivity of the film start to decrease.

  16. Chlorination of some eliphatic organic compounds in liquid and gas phase

    International Nuclear Information System (INIS)

    Hassan, A.A.

    1990-01-01

    The photochlorination of different organic compounds and the relative slectivities of different positions have been investigated in both gaseous and liquid phases at different temperatures. The results have shown that the relative selectivity generally decreased with increasing temperature and in the gas phase has a higher value. Polar solvents increase the selectivity relative to the chlorination of pure liquid phases. The differences in activation energy between two positions were much higher in the gas phases chlorination, relative to that in the liquid phase. It was also found that the functional groups have great influence on the rate of chlorine free radical attack on different positions, for example the electron withdrawing groups decreasing the selectivity on the first position, but the electron donating groups increase the selectivity on the first position, but the electron donating groups increase the selectivity on the first position. Furthermore it was found that the polar solvents, which stabilize the resonance between oxygen and carbon atoms, increases the selectivity on that position. 23 tabs.; 16 figs.; 50 refs

  17. Preparation and Evaluation of Valsartan Liquid Filling Formulations for Soft Gels

    Directory of Open Access Journals (Sweden)

    Jyothi Sanaboina

    2013-01-01

    Full Text Available The present investigation includes the preparation of liquid filling formulations for soft gels using an antihypertensive drug, valsartan (VAL, in order to improve its dissolution properties and thereby its bioavailability. Formulations were prepared using excipients like polyethylene glycol 400 (PEG 400, propylene glycol (PG, polyvinylpyrrolidone (PVP K-30, antioxidants, ethanol, and purified water. Prepared formulations were evaluated for appearance, pH, drug content percentage, viscosity, stability, and in vitro dissolution studies. The compatibility between the drug and excipients in formulations was confirmed by FTIR spectra. The drug contents were in the range of 99.62-99.63 and the viscosity was in the range of 60.9–591.7 cps with all the formulations developed. Formulations containing 10 mg PVP K 30 gave better dissolution properties when compared to formulations without PVP K 30, and a complete drug dissolution was observed within 10 min and followed the first-order release kinetics. Stability studies were conducted for selected formulations (F4–F9 for a period of 6 months at room temperature (~30°C/65% RH. From the studies, it can be concluded that VAL liquid filling formulations for soft gels were successfully prepared with in vitro dissolution properties superior when compared to VAL itself.

  18. Experimental and numerical investigation of stratified gas-liquid flow in inclined circular pipes

    International Nuclear Information System (INIS)

    Faccini, J.L.H.; Sampaio, P.A.B. de; Botelho, M.H.D.S.; Cunha, M.V.; Cunha Filho, J.S.; Su, J.

    2012-01-01

    In this paper, a stratified gas-liquid flow is experimentally and numerically investigated. Two measurement techniques, namely an ultrasonic technique and a visualization technique, are applied on an inclined circular test section using a fast single transducer pulse-echo technique and a high-speed camera. A numerical model is employed to simulate the stratified gas-liquid flow, formed by a system of non-linear differential equations consisting of the Reynolds averaged Navier-Stokes equations with the κ-ω turbulence model. The test section used in this work is comprised mainly of a transparent circular pipe with inner diameter 1 inch, and inclination angles varying from -2.5 to -10.0 degrees. Numerical solutions are obtained for the liquid height as a function of inclination angles, and compared with our own experimental data. (author)

  19. The phase transition of the first order in the critical region of the gas-liquid system

    Directory of Open Access Journals (Sweden)

    I.R. Yukhnovskii

    2014-12-01

    Full Text Available This is a summarising investigation of the events of the phase transition of the first order that occur in the critical region below the liquid-gas critical point. The grand partition function has been completely integrated in the phase-space of the collective variables. The basic density measure is the quartic one. It has the form of the exponent function with the first, second, third and fourth degree of the collective variables. The problem has been reduced to the Ising model in an external field, the role of which is played by the generalised chemical potential μ*. The line μ*(η =0, where η is the density, is the line of the phase transition. We consider the isothermal compression of the gas till the point where the phase transition on the line μ*(η =0 is reached. When the path of the pressing reaches the line μ* =0 in the gas medium, a droplet of liquid springs up. The work for its formation is obtained, the surface-tension energy is calculated. On the line μ* =0 we have a two-phase system: the gas and the liquid (the droplet one. The equality of the gas and of the liquid chemical potentials is proved. The process of pressing is going on. But the pressure inside the system has stopped, two fixed densities have arisen: one for the gas-phase ηG=ηc(1-d/2 and the other for the liquid-phase ηL=ηc(1+d/2 (symmetrically to the rectlinear diameter, where ηc=0.13044 is the critical density. Starting from that moment the external pressure works as a latent work of pressure. Its value is obtained. As a result, the gas-phase disappears and the whole system turns into liquid. The jump of the density is equal to ηc d, where d=(D/2G1/2 ~ τν/2. D and G are coefficients of the Hamiltonian in the last cell connected with the renormalisation-group symmetry. The equation of state is written.

  20. Technology assessment of long distance liquid natural gas pipelines. Phase 8. Cold utilization and rural service

    Energy Technology Data Exchange (ETDEWEB)

    1977-02-01

    This phase of the investigation presents a summary of material relating to: (1) actual or potential applications for the very large refrigeration effects inherent in the vaporization of liquid natural gas; and (2) rural service gas supplies adjacent to the route of a trunk liquid natural gas line. A variety of concepts for cold utilization are discussed. The Canadian prospects for cold utilization include: electric power generation; oxygen production for integration with a coal gasification project; and the use of refrigeration stages in the petrochemical processing of natural gas, for example, ethane separation and processing to produce ethylene and ammonia.

  1. Dynamic simulation of gas-liquid two-phase flow : effect of column aspect ratio on the flow structure

    NARCIS (Netherlands)

    Delnoij, E.; Kuipers, J.A.M.; van Swaaij, W.P.M.

    1997-01-01

    In this paper an Eulerian/Lagrangian model, describing the hydrodynamics of a gas-liquid bubble column, is presented. The model resolves the time dependent, two-dimensional motion of small, spherical gas bubbles in a liquid using the equation of motion. The model incorporates all relevant forces

  2. Dynamic simulation of gas-liquid two-phase flow: effect of column aspect ratio on the flow structure.

    NARCIS (Netherlands)

    Delnoij, E.; Kuipers, J.A.M.; van Swaaij, Willibrordus Petrus Maria

    1997-01-01

    In this paper an Eulerian/Lagrangian model, describing the hydrodynamics of a gas-liquid bubble column, is presented. The model resolves the time dependent, two-dimensional motion of small, spherical gas bubbles in a liquid using the equation of motion. The model incorporates all relevant forces

  3. Automatic crude oil handling through a pressurized system from the wellhead to the refinery

    Energy Technology Data Exchange (ETDEWEB)

    Davis, W.B.; Truman, P.W.; Groeneman, A.R.

    1967-01-01

    Production from 51 wells completed in the 3 unitized formations of the Lost Soldier Field, Sweetwater Co., Wyoming, is brought to a central point through individual flow lines. Here the fluids are directed through separate automatic well testing and oil treating facilities, one for each formation. After separation of oil, gas and water, the oil goes to pressurized surge tanks and then to lease automatic custody transfer units. There is one surge tank and one LACT unit for each formation. The oil is automatically transferred to the Sinclair Pipe Line Co. for delivery to Sinclair's refinery at Sinclair, Wyoming, through a closed pipe line system. A central console provides: (1) supervisory control from the wellheads through the LACT units, (2) well test and production data logging, and (3) monitoring by activating alarms for abnormal conditions of flow, liquid levels, temperatures and pressures.

  4. Emptying device for expendable bottles, especially small counter bottles for radioactive liquids

    International Nuclear Information System (INIS)

    Soltermann, W.

    1975-01-01

    The device cuts up and empties, respectively, counting bottles and vials, respectively, for radioactive liquids. The vials are taken from a magazine and put on transport disks which move them past a circular saw blade cutting the vials into two cups. The liquid pouring out flows through a collection groove into a collection vessel. The two cups are pushed on the arms of a double turnstile by means of guide systems. Gas fed through lines running inside the arms of the turnstiles is used to flush the cups with nitrogen gas. In the downward movement of the double turnstile a catching surface removes the cups or they automatically fall into a collection bag, respectively. Baffle plates hold the vials on the transport disks. (DG/RF) [de

  5. Description of the Gas Transport through Dynamic Liquid Membrane.

    Czech Academy of Sciences Publication Activity Database

    Uchytil, Petr; Setničková, Kateřina; Tseng, H.-H.; Šíma, Vladimír; Petričkovič, Roman

    2017-01-01

    Roč. 184, AUG 31 (2017), s. 152-157 ISSN 1383-5866 Grant - others:AV ČR(CZ) MOST-16-04 Program:Bilaterální spolupráce Institutional support: RVO:67985858 Keywords : gas separation * liquid membrane * solurion-diffusion model Subject RIV: CI - Industrial Chemistry, Chemical Engineering OBOR OECD: Chemical process engineering Impact factor: 3.359, year: 2016

  6. Optimization of two different dispersive liquid-liquid microextraction methods followed by gas chromatography-mass spectrometry determination for polycyclic aromatic hydrocarbons (PAHs) analysis in water.

    Science.gov (United States)

    Tseng, Wan-Chi; Chen, Pai-Shan; Huang, Shang-Da

    2014-03-01

    Novel sample preparation methods termed "up-and-down shaker-assisted dispersive liquid-liquid microextraction (UDSA-DLLME)" and "water with low concentration of surfactant in dispersed solvent-assisted emulsion dispersive liquid-liquid microextraction (WLSEME)" coupled with gas chromatography-mass spectrometry (GC-MS) have been developed for the analysis of 11 polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. For UDSA-DLLME, an up-and-down shaker-assisted emulsification was employed. Extraction was complete in 3min. Only 14 μL of 1-heptanol was required, without a dispersive solvent. Under the optimum conditions, the linear range was 0.08-100 µg L(-1), and the LODs were in the range 0.022-0.060 µg L(-1). The enrichment factors (EFs) ranged from 392 to 766. Relative recoveries were between 84% and 113% for river, lake, and field water. In WLSEME, 9 μL of 1-nonanol as extraction solvent and 240 μL of 1 mg L(-1) Triton X-100 as surfactant were mixed in a microsyringe to form a cloudy emulsified solution, which was then injected into the samples. Compared with other surfactant-assisted emulsion methods, WLSEME uses much less surfactant. The linear range was 0.08-100 µg L(-1), and the LODs were 0.022-0.13 µg L(-1). The EFs ranged from 388 to 649. The relative recoveries were 86-114% for all three water specimens. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Preparation of JEREMI Experiment: Development of the Ground Based Prototype

    Science.gov (United States)

    Yasnou, V.; Mialdun, A.; Shevtsova, V.

    2012-12-01

    This study has been performed in the frame of preparing the space experiment JEREMI (Japanese and European Research Experiment on Marangoni Instabilities). The use of forced coaxial gas flow is proposed as a way to stabilize the Marangoni convection in liquid bridges, which might have important technological applications in the floating zone technique. A new set-up is under development and all sub-systems have passed severe tests. Here we present the design of this set-up and preliminary results of experiments for shear-driven two-phase flows in a confined volume of liquid under conditions of normal gravity. The geometry corresponds to a cylindrical liquid bridge concentrically surrounded by an annular gas channel with external solid walls. Gas enters into the annular duct, flows between solid walls and upon reaching the liquid zone entrains initially quiescent liquid. The test liquids are ethanol, n-decane and 5 cSt silicone oil, which have different degrees of viscosity and of volatility. The gas flow along the interface strongly enhances the evaporation and, correspondingly, affects the interface shape. Silhouette measurements are used for optical determination of the interface shape. From the digital images the variation of the liquid volume as a function of flow rate is calculated.

  8. Numerical simulation study of gas-liquid reactive mass transfer along corrugated sheets with interface tracking

    International Nuclear Information System (INIS)

    Haroun, Y.

    2008-11-01

    This work is done within the framework of gas treatment and CO 2 capture process development. The main objective of the present work is to fill the gap between classical experiments and industrial conditions by the use of Computational Fluid Dynamics (CFD). The physical problem considered corresponds to the liquid film flow down a corrugate surface under gravity in present of a gas phase. The chemical species in the gas phase absorb in the liquid phase and react. Numerical calculations are carried out in order to determine the impact of physical and geometrical properties on reactive mass transfer in industrial operating conditions. (author)

  9. Preparation and evaluation of surface-bonded tricationic ionic liquid silica as stationary phases for high-performance liquid chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2015-05-29

    Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Formation of itraconazole-succinic acid cocrystals by gas antisolvent cocrystallization.

    Science.gov (United States)

    Ober, Courtney A; Gupta, Ram B

    2012-12-01

    Cocrystals of itraconazole, an antifungal drug with poor bioavailability, and succinic acid, a water-soluble dicarboxylic acid, were formed by gas antisolvent (GAS) cocrystallization using pressurized CO(2) to improve itraconazole dissolution. In this study, itraconazole and succinic acid were simultaneously dissolved in a liquid solvent, tetrahydrofuran, at ambient conditions. The solution was then pressurized with CO(2), which decreased the solvating power of tetrahydrofuran and caused crystallization of itraconazole-succinic acid cocrystals. The cocrystals prepared by GAS cocrystallization were compared to those produced using a traditional liquid antisolvent, n-heptane, for crystallinity, chemical structure, thermal behavior, size and surface morphology, potential clinical relevance, and stability. Powder X-ray diffraction, Fourier transform infrared spectroscopy, differential scanning calorimetry, and scanning electron microscopy analyses showed that itraconazole-succinic acid cocrystals with physical and chemical properties similar to cocrystals produced using a traditional liquid antisolvent technique can be prepared by CO(2) antisolvent cocrystallization. The dissolution profile of itraconazole was significantly enhanced through GAS cocrystallization with succinic acid, achieving over 90% dissolution in less than 2 h. The cocrystals appeared stable against thermal stress for up to 4 weeks under accelerated stability conditions, showing only moderate decreases in their degree of crystallinity but no change in their crystalline structure. This study shows the utility of an itraconazole-succinic acid cocrystal for improving itraconazole bioavailability while also demonstrating the potential for CO(2) to replace traditional liquid antisolvents in cocrystal preparation, thus making cocrystal production more environmentally benign and scale-up more feasible.

  11. [Preparation and applications of a supported liquid-liquid extraction column with a composite diatomite material].

    Science.gov (United States)

    Bao, Jianmin; Ma, Zhishuang; Sun, Ying; Wang, Yongzun; Li, Youxin

    2012-08-01

    A rapid and special supported liquid-liquid extraction (SLE) column was developed with a composite diatomite material. The SLE column was evaluated by high performance liquid chromatography (HPLC) with acidic, neutral and alkaline compounds dissolved in water. Furthermore, some real complex samples were also analyzed by HPLC with the SLE method. The recoveries of benzoic acid (acidic), p-nitroaniline (alkaline) and 4-hydroxy-benzoic methyl ester (neutral) treated by the SLE column were 90.6%, 98.1% and 97.7%. However, the recoveries of the three compounds treated by traditional liquid-liquid extraction (LLE) method were 71.9%, 81.9% and 83.9%. The results showed that the SLE technique had higher recoveries than the traditional LLE method. The spiked recoveries of the complex samples, such as benzoic acid in Sprite and dexamethasone acetate, chlorphenamine maleate, indomethacin in bovine serum, were between 80% and 110% and the relative standard deviations (RSDs) were less than 15%. For biological specimen, the results could be accepted. Meantime, many disadvantages associated with traditional LLE method, such as emulsion formation, didn't occur using SLE column. The SLE column technique is a good sample preparation method with many advantages, such as rapid, simple, robust, easily automated, high recovery and high-throughput, which would be widely used in the future.

  12. Preconcentration in gas or liquid phases using adsorbent thin films

    Directory of Open Access Journals (Sweden)

    Antonio Pereira Nascimento Filho

    2006-03-01

    Full Text Available The possibility of preconcentration on microchannels for organic compounds in gas or liquid phases was evaluated. Microstructures with different geometries were mechanically machined using poly(methyl methacrylate - PMMA as substrates and some cavities were covered with cellulose. The surfaces of the microchannels were modified by plasma deposition of hydrophilic or hydrophobic films using 2-propanol and hexamethyldisilazane (HMDS, respectively. Double layers of HMDS + 2-propanol were also used. Adsorption characterization was made by Quartz Crystal Measurements (QCM technique using reactants in a large polarity range that showed the adsorption ability of the structures depends more on the films used than on the capillary phenomena. Cellulose modified by double layer film showed a high retention capacity for all gaseous compounds tested. However, structures without plasma deposition showed low retention capacity. Microchannels modified with double layers or 2-propanol plasma films showed higher retention than non-modified ones on gas or liquid phase.

  13. Development of energy-efficient processes for natural gas liquids recovery

    International Nuclear Information System (INIS)

    Yoon, Sekwang; Binns, Michael; Park, Sangmin; Kim, Jin-Kuk

    2017-01-01

    A new NGL (natural gas liquids) recovery process configuration is proposed which can offer improved energy efficiency and hydrocarbon recovery. The new process configuration is an evolution of the conventional turboexpander processes with the introduction of a split stream transferring part of the feed to the demethanizer column. In this way additional heat recovery is possible which improves the energy efficiency of the process. To evaluate the new process configuration a number of different NGL recovery process configurations are optimized and compared using a process simulator linked interactively with external optimization methods. Process integration methodology is applied as part of the optimization to improve energy recovery during the optimization. Analysis of the new process configuration compared with conventional turbo-expander process designs demonstrates the benefits of the new process configuration. - Highlights: • Development of a new energy-efficient natural gas liquids recovery process. • Improving energy recovery with application of process integration techniques. • Considering multiple different structural changes lead to considerable energy savings.

  14. Maximize Liquid Oil Production from Shale Oil and Gas Condensate Reservoirs by Cyclic Gas Injection

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, James [Texas Tech Univ., Lubbock, TX (United States); Li, Lei [Texas Tech Univ., Lubbock, TX (United States); Yu, Yang [Texas Tech Univ., Lubbock, TX (United States); Meng, Xingbang [Texas Tech Univ., Lubbock, TX (United States); Sharma, Sharanya [Texas Tech Univ., Lubbock, TX (United States); Huang, Siyuan [Texas Tech Univ., Lubbock, TX (United States); Shen, Ziqi [Texas Tech Univ., Lubbock, TX (United States); Zhang, Yao [Texas Tech Univ., Lubbock, TX (United States); Wang, Xiukun [Texas Tech Univ., Lubbock, TX (United States); Carey, Bill [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Nguyen, Phong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Porter, Mark [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jimenez-Martinez, Joaquin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Viswanathan, Hari [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mody, Fersheed [Apache Corp., Houston, TX (United States); Barnes, Warren [Apache Corp., Houston, TX (United States); Cook, Tim [Apache Corp., Houston, TX (United States); Griffith, Paul [Apache Corp., Houston, TX (United States)

    2017-11-17

    The current technology to produce shale oil reservoirs is the primary depletion using fractured wells (generally horizontal wells). The oil recovery is less than 10%. The prize to enhance oil recovery (EOR) is big. Based on our earlier simulation study, huff-n-puff gas injection has the highest EOR potential. This project was to explore the potential extensively and from broader aspects. The huff-n-puff gas injection was compared with gas flooding, water huff-n-puff and waterflooding. The potential to mitigate liquid blockage was also studied and the gas huff-n-puff method was compared with other solvent methods. Field pilot tests were initiated but terminated owing to the low oil price and the operator’s budget cut. To meet the original project objectives, efforts were made to review existing and relevant field projects in shale and tight reservoirs. The fundamental flow in nanopores was also studied.

  15. Maxwell's Law Based Models for Liquid and Gas Phase Diffusivities in Variably-Saturated Soil

    DEFF Research Database (Denmark)

    Mamamoto, Shoichiro; Møldrup, Per; Kawamoto, Ken

    2012-01-01

    -s,D-l). Different percolation threshold terms adopted from recent studies for gas (D-s,D-g) and solute (D-s,D-l) diffusion were applied. For gas diffusion, epsilon(th) was a function of bulk density (total porosity), while for solute diffusion theta(th) was best described by volumetric content of finer soil...... particles (clay and organic matter), FINESvol. The resulting LIquid and GAs diffusivity and tortuosity (LIGA) models were tested against D-s,D-g and D-s,D-l data for differently-textured soils and performed well against the measured data across soil types. A sensitivity analysis using the new Maxwell's Law...... based LIGA models implied that the liquid phase but not the gaseous-phase tortuosity was controlled by soil type. The analyses also suggested very different pathways and fluid-phase connectivity for gas and solute diffusion in unsaturated soil...

  16. PERFORMANCE, EMISSION, AND COMBUSTION CHARACTERISTICS OF A CI ENGINE USING LIQUID PETROLEUM GAS AND NEEM OIL IN DUAL FUEL MODE

    Directory of Open Access Journals (Sweden)

    Palanimuthu Vijayabalan

    2010-01-01

    Full Text Available Increased environmental awareness and depletion of resources are driving the industries to develop viable alternative fuels like vegetable oils, compresed natural gas, liquid petroleum gas, producer gas, and biogas in order to provide suitable substitute to diesel for compression ignition engine. In this investigation, a single cylinder, vertical, air-cooled diesel engine was modified to use liquid petroleum gas in dual fuel mode. The liquefied petroleum gas, was mixed with air and supplied through intake manifold. The liquid fuel neem oil or diesel was injected into the combustion chamber. The performance, emission, and combustion characteristics were studied and compared for neat fuel and dual fuel mode. The experimental results on dual fuel engine show a reduction in oxides of nitrogen up to 70% of the rated power and smoke in the entire power range. However the brake thermal efficiency was found decreased in low power range due to lower calorific value of liquid petroleum gas, and increase in higher power range due to the complete burning of liquid petroleum gas. Hydrocarbon and carbon monoxide emissions were increased significantly at lower power range and marginal variation in higher power range.

  17. Continuous fixed-bed gas-phase hydroformylation using supported ionic liquid-phase (SILP) Rh catalysts

    DEFF Research Database (Denmark)

    Riisager, Anders; Wasserscheid, Peter; Van Hal, R.

    2003-01-01

    Continuous flow gas-phase hydroformylation of propene was performed using novel supported ionic liquid-phase (SILP) catalysts containing immobilized Rh complexes of the biphosphine ligand sulfoxantphos in the ionic liquids 1-n-butyl-3-methylimidazolium hexafluorophosphate and halogen-free 1-n-butyl...

  18. Adding Some Gas Can Completely Change How an Object in a Liquid-Filled Housing Responds to Vibration

    Science.gov (United States)

    Torczynski, J. R.; O'Hern, T. J.; Clausen, J. R.

    2015-11-01

    Adding a little gas can completely change the motion of an object in a liquid-filled housing during vibration. A common system exhibiting this behavior is a spring-supported piston in a liquid-filled cylinder, where the gaps between them are narrow and depend on the piston position. When gas is absent, the piston's vibrational response is highly overdamped due to forcing viscous liquid through narrow gaps. When a small amount of gas is added, Bjerknes forces cause some of the gas to migrate below the piston. The resulting two gas regions form a pneumatic spring that enables the liquid to move with the piston, with the result that very little liquid is forced through the narrow gaps. This ``Couette mode'' has low damping and thus has a strong resonance near the frequency given by the pneumatic spring constant and the piston mass. At this frequency, the piston response is large, and the nonlinearity from the gap geometry produces a net force on the piston. This ``rectified'' force can be many times the piston's weight and can cause the piston to compress its supporting spring. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  19. Using artificial intelligence to improve identification of nanofluid gas-liquid two-phase flow pattern in mini-channel

    Science.gov (United States)

    Xiao, Jian; Luo, Xiaoping; Feng, Zhenfei; Zhang, Jinxin

    2018-01-01

    This work combines fuzzy logic and a support vector machine (SVM) with a principal component analysis (PCA) to create an artificial-intelligence system that identifies nanofluid gas-liquid two-phase flow states in a vertical mini-channel. Flow-pattern recognition requires finding the operational details of the process and doing computer simulations and image processing can be used to automate the description of flow patterns in nanofluid gas-liquid two-phase flow. This work uses fuzzy logic and a SVM with PCA to improve the accuracy with which the flow pattern of a nanofluid gas-liquid two-phase flow is identified. To acquire images of nanofluid gas-liquid two-phase flow patterns of flow boiling, a high-speed digital camera was used to record four different types of flow-pattern images, namely annular flow, bubbly flow, churn flow, and slug flow. The textural features extracted by processing the images of nanofluid gas-liquid two-phase flow patterns are used as inputs to various identification schemes such as fuzzy logic, SVM, and SVM with PCA to identify the type of flow pattern. The results indicate that the SVM with reduced characteristics of PCA provides the best identification accuracy and requires less calculation time than the other two schemes. The data reported herein should be very useful for the design and operation of industrial applications.

  20. Greenhouse Gas Emissions from Solid and Liquid Organic Fertilizers Applied to Lettuce.

    Science.gov (United States)

    Toonsiri, Phasita; Del Grosso, Stephen J; Sukor, Arina; Davis, Jessica G

    2016-11-01

    Improper application of nitrogen (N) fertilizer and environmental factors can cause the loss of nitrous oxide (NO) to the environment. Different types of fertilizers with different C/N ratios may have different effects on the environment. The focus of this study was to evaluate the effects of environmental factors and four organic fertilizers (feather meal, blood meal, fish emulsion, and cyano-fertilizer) applied at different rates (0, 28, 56, and 112 kg N ha) on NO emissions and to track CO emissions from a lettuce field ( L.). The study was conducted in 2013 and 2014 and compared preplant-applied solid fertilizers (feather meal and blood meal) and multiple applications of liquid fertilizers (fish emulsion and cyano-fertilizer). Three days a week, NO and CO emissions were measured twice per day in 2013 and once per day in 2014 using a closed-static chamber, and gas samples were analyzed by gas chromatography. Preplant-applied solid fertilizers significantly increased cumulative NO emissions as compared with control, but multiple applications of liquid fertilizers did not. Emission factors for NO ranged from 0 to 0.1% for multiple applications of liquid fertilizers and 0.6 to 11% for preplant-applied solid fertilizers, which could be overestimated due to chamber placement over fertilizer bands. In 2014, solid fertilizers with higher C/N ratios (3.3-3.5) resulted in higher CO emissions than liquid fertilizers (C/N ratio, 0.9-1.5). Therefore, organic farmers should consider the use of multiple applications of liquid fertilizers as a means to reduce soil greenhouse gas emissions while maintaining high yields. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  1. Options for Gas-to-Liquids Technology in Alaska

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Eric Partridge

    1999-10-01

    The purposes of this work was to assess the effect of applying new technology to the economics of a proposed natural gas-to-liquids (GTL) plant, to evaluate the potential of a slower-paced, staged deployment of GTL technology, and to evaluate the effect of GTL placement of economics. Five scenarios were economically evaluated and compared: a no-major-gas-sales scenario, a gas-pipeline/LNG scenario, a fast-paced GTL development scenario, a slow-paced GTL development scenario, and a scenario which places the GTL plant in lower Alaska, instead of on the North Slope. Evaluations were completed using an after-tax discounted cash flow analysis. Results indicate that the slow-paced GTL scenario is the only one with a rate of return greater than 10 percent. The slow-paced GTL development would allow cost saving on subsequent expansions. These assumed savings, along with the lowering of the transportation tariff, combine to distinquish this option for marketing the North Slope gas from the other scenarios. Critical variables that need further consideration include the GTL plant cost, the GTL product premium, and operating and maintenance costs.

  2. An introduction to automatic radioactive sample counters

    International Nuclear Information System (INIS)

    1980-01-01

    The subject is covered in chapters, entitled; the detection of radiation in sample counters; nucleonic equipment; liquid scintillation counting; basic features of automatic sample counters; statistics of counting; data analysis; purchase, installation, calibration and maintenance of automatic sample counters. (U.K.)

  3. Installation for gas purification and gas mixture preparation

    International Nuclear Information System (INIS)

    Ciortea, Constantin; Dumitrescu, Ioana; Armeanu, Adrian

    2002-01-01

    The Gas Production Division of ICSI at Rm. Valcea developed advanced facilities for purification of hydrogen, nitrogen, methane gases, etc, with concentrations up to 99.999 % vol. Pure and ultrapure gases are used for analytical purposes in food industry, biology, medicine, research laboratories, chemical and metallurgical industries. In the frame of ICSI the purified gases are used for preparation of usual and special mixtures of gases as for instance for production of Ar + CO 2 , Ar + CH 4 , Ar + H 2 , Ar + N 2 , N 2 + CO 2 , N 2 + O 2 etc. These mixtures are required in diverse sectors of chemical, electrical, machine and food industry, in nuclear power plants for monitoring, in laboratories of equipment calibrations, etc. (authors)

  4. Visualization and measurement of gas-liquid metal two-phase flow with large density difference using thermal neutrons as microscopic probes

    International Nuclear Information System (INIS)

    Mishima, K.; Hibiki, T.; Saito, Y.; Nishihara, H.; Tobita, Y.; Konishi, K.; Matsubayashi, M.

    1999-01-01

    In a core melt accident of a fast breeder reactor, there is a possibility of boiling of the fuel-steel mixture in the containment pool. In relation to safety evaluation on severe accident, it is indispensable to evaluate the possibility of re-criticality of melted core. Gas-liquid two-phase flow with a large liquid-to-gas density ratio is formed due to the boiling of fuel-steel mixture. Although it is anticipated that the large density ratio may affect the basic characteristics of two-phase flow, little work has been performed so far on two-phase flow with a large liquid-to-gas density ratio. In this study, visualization and void fraction measurement of gas-liquid metal two-phase flow were performed by using neutron radiography and image processing techniques. Then, the effect of large density difference between gas and liquid phases on the basic flow characteristics of two-phase flow was clarified

  5. Influence of liquid viscosity and surface tension on the gas-liquid mass transfer coefficient for solid foam packings in co-current two-phase flow

    NARCIS (Netherlands)

    Stemmet, C.P.; Bartelds, F.; Schaaf, van der J.; Kuster, B.F.M.; Schouten, J.C.

    2008-01-01

    The gas–liquid mass transfer coefficient and other hydrodynamic parameters such as liquid holdup and frictional pressure drop are presented for gas and liquid moving in co-current upflow and downflow through solid foam packings of 10 and of 40 pores per linear inch (ppi). The effect of increasing

  6. Infra-Red Gas Analysers of Liquid Crystal Type for Environmental Monitoring

    Directory of Open Access Journals (Sweden)

    V. I. Nazarov

    2004-01-01

    Full Text Available The paper reveals an opportunity to use infra-red gas analysers on the basis of the developed dichroic liquid crystal cells for investigation of absorption bands of various gases in the near infrared spectral region.

  7. An automatic refolding apparatus for preparative-scale protein production.

    Directory of Open Access Journals (Sweden)

    Yanye Feng

    Full Text Available Protein refolding is an important process to recover active recombinant proteins from inclusion bodies. Refolding by simple dilution, dialysis and on-column refolding methods are the most common techniques reported in the literature. However, the refolding process is time-consuming and laborious due to the variability of the behavior of each protein and requires a great deal of trial-and-error to achieve success. Hence, there is a need for automation to make the whole process as convenient as possible. In this study, we invented an automatic apparatus that integrated three refolding techniques: varying dilution, dialysis and on-column refolding. We demonstrated the effectiveness of this technology by varying the flow rates of the dilution buffer into the denatured protein and testing different refolding methods. We carried out different refolding methods on this apparatus: a combination of dilution and dialysis for human stromal cell-derived factor 1 (SDF-1/CXCL12 and thioredoxin fused-human artemin protein (Trx-ARTN; dilution refolding for thioredoxin fused-human insulin-like growth factor I protein (Trx-IGF1 and enhanced fluorescent protein (EGFP; and on-column refolding for bovine serum albumin (BSA. The protein refolding processes of these five proteins were preliminarily optimized using the slowly descending denaturants (or additives method. Using this strategy of decreasing denaturants concentration, the efficiency of protein refolding was found to produce higher quantities of native protein. The standard refolding apparatus configuration can support different operations for different applications; it is not limited to simple dilution, dialysis and on-column refolding techniques. Refolding by slowly decreasing denaturants concentration, followed by concentration or purification on-column, may be a useful strategy for rapid and efficient recovery of active proteins from inclusion bodies. An automatic refolding apparatus employing this

  8. Local Nusselt number enhancement during gas-liquid Taylor bubble flow in a square mini-channel: An experimental study

    International Nuclear Information System (INIS)

    Majumder, Abhik; Mehta, Balkrishna; Khandekar, Sameer

    2013-01-01

    Taylor bubble flow takes place when two immiscible fluids (liquid-liquid or gas-liquid) flow inside a tube of capillary dimensions within specific range of volume flow ratios. In the slug flows where gas and liquid are two different phases, liquid slugs are separated by elongated Taylor bubbles. This singular flow pattern is observed in many engineering mini-/micro-scale devices like pulsating heat pipes, gas-liquid-solid monolithic reactors, micro-two-phase heat exchangers, digital micro-fluidics, micro-scale mass transfer process, fuel cells, etc. The unique and complex flow characteristics require understanding on local, as well as global, spatio-temporal scales. In the present work, the axial stream-wise profile of the fluid and wall temperature for air-water (i) isolated single Taylor bubble and, (ii) a train of Taylor bubbles, in a horizontal square channel of size 3.3 mm x 3.3 mm x 350 mm, heated from the bottom (heated length = 175 mm), with the other three sides kept insulated, are reported at different gas volume flow ratios. The primary aim is to study the enhancement of heat transfer due to the Taylor bubble train flow, in comparison with thermally developing single-phase flows. Intrusion of a bubble in the liquid flow drastically changes the local temperature profiles. The axial distribution of time-averaged local Nusselt number (Nu z ) shows that Taylor bubble train regime increases the transport of heat up to 1.2-1.6 times more as compared with laminar single-phase liquid flow. In addition, for a given liquid flow Reynolds number, the heat transfer enhancement is a function of the geometrical parameters of the unit cell, i.e., the length of adjacent gas bubble and water plug. (authors)

  9. Structure of the gas-liquid annular two-phase flow in a nozzle section

    International Nuclear Information System (INIS)

    Yoshida, Kenji; Kataoka, Isao; Ohmori, Syuichi; Mori, Michitsugu

    2006-01-01

    Experimental studies on the flow behavior of gas-liquid annular two-phase flow passing through a nozzle section were carried out. This study is concerned with the central steam jet injector for a next generation nuclear reactor. In the central steam jet injector, steam/water annular two-phase flow is formed at the mixing nozzle. To make an appropriate design and to establish the high-performance steam injector system, it is very important to accumulate the fundamental data of the thermo-hydro dynamic characteristics of annular flow passing through a nozzle section. On the other hand, the transient behavior of multiphase flow, in which the interactions between two-phases occur, is one of the most interesting scientific issues and has attracted research attention. In this study, the transient gas-phase turbulence modification in annular flow due to the gas-liquid phase interaction is experimentally investigated. The annular flow passing through a throat section is under the transient state due to the changing cross sectional area of the channel and resultantly the superficial velocities of both phases are changed compared with a fully developed flow in a straight pipe. The measurements for the gas-phase turbulence were precisely performed by using a constant temperature hot-wire anemometer, and made clear the turbulence structure such as velocity profiles, fluctuation velocity profiles. The behavior of the interfacial waves in the liquid film flow such as the ripple or disturbance waves was also observed. The measurements for the liquid film thickness by the electrode needle method were also performed to measure the base film thickness, mean film thickness, maximum film thickness and wave height of the ripple or the disturbance waves. (author)

  10. Use of membrane separation processes for the separation of radionuclides from liquid and gas streams

    International Nuclear Information System (INIS)

    Vladisavljevic, G.T.; Rajkovic, M.B.

    1999-01-01

    Use of membranes for the separation and recovery of radionuclides from contaminated liquid and gas streams has been discussed in this paper. The special attention has been paid to the use of ion-exchange membranes for electrodialysis and Donnan dialysis, as well as the use of facilitated liquid membranes for liquid pertraction. (author)

  11. Determination of Diffusion Coefficients and Activation Energy of Selected Organic Liquids using Reversed-Flow Gas Chromatographic Technique

    International Nuclear Information System (INIS)

    Khalisanni Khalid; Rashid Atta Khan; Sharifuddin Mohd Zain

    2012-01-01

    Evaporation of vaporize organic liquid has ecological consequences when the compounds are introduced into both freshwater and marine environments through industrial effluents, or introduced directly into the air from industrial unit processes such as bioreactors and cooling towers. In such cases, a rapid and simple method are needed to measure physicochemical properties of the organic liquids. The Reversed-Flow Gas Chromatography (RF-GC) sampling technique is an easy, fast and accurate procedure. It was used to measure the diffusion coefficients of vapors from liquid into a carrier gas and at the same time to determine the rate coefficients for the evaporation of the respective liquid. The mathematical expression describing the elution curves of the samples peaks was derived and used to calculate the respective parameters for the selected liquid pollutants selected such as methanol, ethanol, 1-propanol, 1-butanol, n-pentane, n-hexane, n-heptane and n-hexadecane, evaporating into the carrier gas of nitrogen. The values of diffusion coefficients found were compared with those calculated theoretically or reported in the literature. The values of evaporation rate were used to determine the activation energy of respective samples using Arrhenius equation. An interesting finding of this work is by using an alternative mathematical analysis based on equilibrium at the liquid-gas interphase, the comparison leads to profound agreement between theoretical values of diffusion coefficients and experimental evidence. (author)

  12. Film thickness in gas-liquid two-phase flow, (4)

    International Nuclear Information System (INIS)

    Fukano, Toru; Sekoguchi, Kotohiko; Kawakami, Yasushi; Shimizu, Hideo.

    1979-01-01

    This paper reports in detail on the thinning process of water film by means of the drainage that appears directly under an obstacle inserted against the flow into the gas-liquid two-phase flow in a tube. The equipment is the same as that used for the first study, in which the orifice type obstacle of 5 mm long having the area ratio of 0.235 was used. This obstacle is the one for which the most significant drainage was observed in the previous study. The change of liquid film in course of time was measured by the constant current method as described before. First, the premising conditions and duration of the drainage are considered. In the thinning by drainage, water film became about 0.1 mm at the early stage of 0.1 sec from its start, then the whole water film became the flow governed by viscosity (called viscous water film). After this state, the film became thinner very slowly. The viscous film is thicker as it is apart farther from the obstacle. If the flow conditions show significant drainage, the duration of drainage directly under the obstacle is nearly equal to the passing time of gas slug. When the thinning of water film is accelerated by drainage, it might cause the possible disappearance of water film when gas slug passes, even if the thermal load is comparatively low. (Wakatsuki, Y.)

  13. Tuning of Preparational Factors Affecting the Morphological Structure and Gas Separation Property of Asymmetric Polysulfone Membranes

    Science.gov (United States)

    Yuenyao, C.; Ruangdit, S.; Chittrakarn, T.

    2017-09-01

    The aim of this work was to study the effect of preparational factors such as solvent type, evaporation time (ET) and non-solvent additive, on the morphological structure, physical and gas separation properties of the prepared membrane samples by tuning of these parameters. Flat sheet asymmetric polysulfone (PSF) membranes were prepared by the dry/wet phase inversion process combined with the double coagulation bath method. The alteration of the prepared membranes were analyzed through scientific techniques such as Scanning Electron Microscope (SEM) and Dynamic Mechanical Thermal Analysis (DMTA). Furthermore, gas separation performance of membrane samples was measured in term of gas permeation and ideal selectivity of CO2/CH4. Experimental results showed that the change of preparational factors affected to the gas permeation of asymmetric PSF membranes. For example, the selective layer thickness increased with increasing of ET. This lead to increase significantly of ideal selectivity of CO2/CH4. The CO2/CH4 ideal selectivity was also increased with increase of ethanol (non-solvent additive) concentration in casting solution. In summary, the tuning of preparational factors affected to morphological structure, physical and gas separation properties of PSF membranes.

  14. Structure of strongly underexpanded gas jets submerged in liquids – Application to the wastage of tubes by aggressive jets

    Energy Technology Data Exchange (ETDEWEB)

    Roger, Francis, E-mail: roger@ensma.fr [Institut PPRIME, Département Fluides, Thermique, Combustion CNRS ENSMA Université de Poitiers UPR 3346, ENSMA BP 109, 86960 Futuroscope Cedex (France); Carreau, Jean-Louis; Gbahoué, Laurent; Hobbes, Philippe [Institut PPRIME, Département Fluides, Thermique, Combustion CNRS ENSMA Université de Poitiers UPR 3346, ENSMA BP 109, 86960 Futuroscope Cedex (France); Allou, Alexandre; Beauchamp, François [CEA, DEN, Cadarache, DTN/STPA/LTRS, 13108 Saint-Paul lez, Durance Cedex (France)

    2014-07-01

    Highlights: • Underexpanded gas jets submerged in liquids behave similarly to homogeneous gas jets. • The counter rotating vortex pairs of jet produce discrete imprints on the targets. • The shape of hollows made on the targets is explained by the jet structure. • The erosion–corrosion phenomenon well explains the wastage of exchange tubes. - Abstract: Strongly underexpanded gas jets submerged in a liquid at rest behave similarly to underexpanded homogeneous gas jets. The existence of the Taylor-Görtler vortices around the inner zone of the gas jets is demonstrated in free gas jets submerged in water by means of optical probe. In the near field, the same phenomenon produces discrete imprints, approximately distributed in a circle, when underexpanded nitrogen jet submerged in liquid sodium hydroxide and underexpanded water vapour jet submerged in liquid sodium impact onto AU{sub 4}G-T{sub 4} and Incoloy 800{sup ®} alloy targets respectively. For a jet-target couple, the volume of the hollow is satisfactorily related to the strain energy density of the material and the kinetic energy of the gas jet. However, the comparison between volumes of hollows produced by both jets also indicates strong corrosive action of the medium on targets. This allows better understanding of the mechanism of wastage of tubes employed in steam generators integrated in liquid metal fast breeder reactors.

  15. Heat transfer by liquids in suspension in a turbulent gas stream (1960); Transfert de chaleur par liquides entraines dans un ecoulement gazeux turbulent (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Grison, E [Commissariat a l' Energie Atomique, Lab. de Physique-Chimie et basses temperatures, Grenoble (France).Centre d' Etudes Nucleaires; Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The introduction of a small volume of liquid into a turbulent gas stream used as cooling agent improves considerably the heat transfer coefficient of the gas. When the turbulent regime is established, one observes in a cylindrical tube two types of flow whether the liquid wets or does not wet the wall. In the first case, one gets on the wall an annular liquid film and droplets in suspension are in the gas stream. In the second case, a fog of droplets is formed without any liquid film on the wall. Experiments were performed with the following mixtures: water-hydrogen, water-nitrogen, ethanol-nitrogen (wetting liquids) introduced into a stainless steel tube of 4 mm ID, electrically heated on 320 mm of length. We varied the gas flow rate (Reynolds until 50000), the rate of the liquid flow rate to gas flow rate (until 15), the pressure (until 10 kg/cm{sup 2}), the temperature (until the boiling point) and the heat flux (until 250 W/cm{sup 2}). Two types of burnout were observed. A formula of correlation of the burnout heat flux is given. Making use of the analogy between mass transfer and heat transfer, a dimensionless formula of correlation of the local heat transfer coefficients is established. (author) [French] L'introduction d'un faible volume de liquide dans un ecoulement gazeux turbulent utilise comme fluide refrigerant permet une amelioration considerable des coefficients d'echanges thermiques que l'on aurait si le gaz etait employe seul (nous avons obtenu un facteur d'amelioration superieur a 10). En regime turbulent etabli, on observe dans un tube deux modes d'ecoulements selon que le liquide mouille ou ne mouille pas la paroi. Dans le premier cas, on obtient sur la paroi un film annulaire liquide et des gouttelettes en suspension dans le coeur gazeux. Dans le deuxieme cas, il se forme un veritable brouillard sans film liquide sur la paroi. Les etudes experimentales ont ete effectuees avec les melanges eau-hydrogene, eau-azote, ethanol-azote (liquides

  16. Integration of power to gas/power to liquid in the ongoing transformation processes; Integration von Power to Gas/Power to Liquid in den laufenden Transformationsprozess

    Energy Technology Data Exchange (ETDEWEB)

    Purr, Katja; Osiek, Dirk; Lange, Martin; and others

    2016-03-15

    The objective of this position paper is to assess from the current level of knowledge of the Federal Environment Agency the role and perspective of power to gas / power to Liquid (PtG / PtL) in a fully renewable energy system and in particular to appoint the challenges of integration and further development of this technique in the current transformation process in the next few years. Here also the comparison to other Power to X-options and their greenhouse gas reduction effect is shown. The geographic focus of the considerations is on Germany, knowing that a full renewable energy supply in Germany must be especially for economic reasons embedded in a long term international energy policy. [German] Ziel dieses Positionspapiers ist es, aus dem derzeitigen Kenntnisstand des Umweltbundesamts die Rolle und Perspektive von Power to Gas/Power to Liquid (PtG/PtL) in einem vollstaendig regenerativen Energiesystem einzuschaetzen und insbesondere die Herausforderungen bei der Integration und Weiterentwicklung dieser Technik im laufenden Transformationsprozess in den naechsten Jahren zu benennen. Dabei wird auch der Vergleich zu anderen Power to X-Optionen und deren Treibhausgasminderungswirkung dargestellt. Der geografische Fokus der Betrachtungen liegt dabei auf Deutschland, wohlwissend, dass eine vollstaendige regenerative Energieversorgung Deutschlands insbesondere aus oekonomischen Gruenden langfristig in eine internationale Energiepolitik eingebettet sein muss.

  17. Separation of krypton from dissolver off-gas of a reprocessing plant using preparative gas chromatography

    International Nuclear Information System (INIS)

    Matoni, M.

    1984-02-01

    Kr-85 can be separated from the pre-purified purge air in the final processing step of the purification phase for dissolver off-gases of a reprocessing plant with the aid of preparative gas chromatography. Activated carbon adsorbers in combination with helium as carrier gas permits maximum gas mixture through-flow. A separation temperature of 30 0 C is considered optimal. An adsorbent volume of 40 dm 3 is necessary for processing the residual gas flow of 2.5 Nm 3 /h; the adsorbent is divided between 2 columns linked in series each of which are 2 m long with an internal diameter of 100 mm. The helium flow required is five times greater than the off-gas flow. The degree of purity for krypton is greater than 90% for a decontamination factor of greater than 1000. (orig./HP) [de

  18. Remotely operated organic liquid waste incinerator for the fuels and materials examination facility

    International Nuclear Information System (INIS)

    Sales, W.L.; Barker, R.E.; Hershey, R.B.

    1980-01-01

    The search for a practical method for the disposal of small quantities of oraganic liquid waste, a waste product of metallographic sample preparation at the Fuels and Materials Examination Facility has led to the design of an incinerator/off-gas system to burn organic liquid wastes and selected organic solids. The incinerator is to be installed in a shielded inert-atmosphere cell, and will be remotely operated and maintained. The off-gas system is a wet-scrubber and filter system designed to release particulate-free off-gas to the FMEF Building Exhaust System

  19. Feasibility study of automatic control of crew comfort in the shuttle Extravehicular Mobility Unit. [liquid cooled garment regulator

    Science.gov (United States)

    Cook, D. W.

    1977-01-01

    Computer simulation is used to demonstrate that crewman comfort can be assured by using automatic control of the inlet temperature of the coolant into the liquid cooled garment when input to the controller consists of measurements of the garment inlet temperature and the garment outlet temperature difference. Subsequent tests using a facsimile of the control logic developed in the computer program confirmed the feasibility of such a design scheme.

  20. Treatment of Dye Wastewater by Using a Hybrid Gas/Liquid Pulsed Discharge Plasma Reactor

    International Nuclear Information System (INIS)

    Lu Na; Li Jie; Wu Yan; Masayuki, Sato

    2012-01-01

    A hybrid gas/liquid pulsed discharge plasma reactor using a porous ceramic tube is proposed for dye wastewater treatment. High voltage pulsed discharge plasma was generated in the gas phase and simultaneously the plasma channel was permeated through the tiny holes of the ceramic tube into the water phase accompanied by gas bubbles. The porous ceramic tube not only separated the gas phase and liquid phase but also offered an effective plasma spreading channel. The effects of the peak pulse voltage, additive gas varieties, gas bubbling rate, solution conductivity and TiO 2 addition were investigated. The results showed that this reactor was effective for dye wastewater treatment. The decoloration efficiency of Acid Orange II was enhanced with an increase in the power supplied. Under the studied conditions, 97% of Acid Orange II in aqueous solution was effectively decolored with additive oxygen gas, which was 51% higher than that with argon gas, and the increasing O 2 bubbling rate also benefited the decoloration of dye wastewater. Water conductivity had a small effect on the level of decoloration. Catalysis of TiO 2 could be induced by the pulsed discharge plasma and addition of TiO 2 aided the decoloration of Acid Orange II.

  1. Chemometric strategy for automatic chromatographic peak detection and background drift correction in chromatographic data.

    Science.gov (United States)

    Yu, Yong-Jie; Xia, Qiao-Ling; Wang, Sheng; Wang, Bing; Xie, Fu-Wei; Zhang, Xiao-Bing; Ma, Yun-Ming; Wu, Hai-Long

    2014-09-12

    Peak detection and background drift correction (BDC) are the key stages in using chemometric methods to analyze chromatographic fingerprints of complex samples. This study developed a novel chemometric strategy for simultaneous automatic chromatographic peak detection and BDC. A robust statistical method was used for intelligent estimation of instrumental noise level coupled with first-order derivative of chromatographic signal to automatically extract chromatographic peaks in the data. A local curve-fitting strategy was then employed for BDC. Simulated and real liquid chromatographic data were designed with various kinds of background drift and degree of overlapped chromatographic peaks to verify the performance of the proposed strategy. The underlying chromatographic peaks can be automatically detected and reasonably integrated by this strategy. Meanwhile, chromatograms with BDC can be precisely obtained. The proposed method was used to analyze a complex gas chromatography dataset that monitored quality changes in plant extracts during storage procedure. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. GIS (Geographic Information Systems) based automatic tool for selection of gas pipeline corridors

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Denise F.; Menezes, Paulo Cesar P.; Paz, Luciana R.L.; Garcia, Katia C.; Cruz, Cristiane B.; Pires, Silvia H.M.; Damazio, Jorge M.; Medeiros, Alexandre M.

    2009-07-01

    This paper describes a methodology developed to build total accumulated surfaces in order to better select gas pipelines corridor alternatives. The methodology is based on the minimization of negative impacts and the use of Geographic Information Systems (GIS), allowing an automatic method of construction, evaluation and selection of alternatives, that will contribute to the decision making process. It is important to emphasize that this paper follows the assumptions presented on the research reports of a project sponsored by the Ministry of Mines and Energy (MME) and elaborated at the Electric Power Research Center (CEPEL), called 'Development of a Geographic Information System to Oil and Gas Sectors in Brazil', and also the studies d GTW Project (Gas to Wire). Gas pipelines, as for their linear characteristic, may cross a variety of habitats and settlements, increasing the complexity of their environmental management. Considering this reality, this paper presents a methodology that takes into account different environmental criteria (layers), according to the area impacted. From the synthesis of the criteria it is presented the total accumulated surface. It is showed an example of a hypothetical gas pipeline connection between two points using the total accumulated surface. To select the 'impact scores' of the features, the gas pipeline was considered as a linear feature, but the result is a region, formed by pixels, each pixel with an accumulated impact score lower than some arbitrary measure. This region is called 'corridor', and it is the final result obtained using the proposed methodology. (author)

  3. Heat transfer by gas-liquid mixture in forced turbulent flow with weak vaporization of the liquid phase (1962); Transfert de chaleur par melange de liquide et de gaz en convection forcee turbulente avec faible vaporisation de la phase liquide (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Huyghe, J; Mondin, G [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    The present study deals with measures of heat transfer and pressure drop in two-phase liquid flow. The stream is of annular dispersed type, obtained by introducing a small quantity of liquid in a gas turbulent flow. The heat transfer experiments are performed without vaporization of the liquid phase. A notable improvement of the heat transfer coefficient of such a stream is observed, compared with a gas-alone or liquid-alone flow. The improvement concerning the gas-alone is of about 20 when it is compared with the same gas Reynolds's number, of about 8 when it is compared with the same total mass flow rate. A hydrodynamic study of the flow pattern lets us know the original structure of the flow, and allows to foresee the experimental results by means of a simplified theory. (authors) [French] II est fait etat de mesures de transfert thermique et de perte de charge dans un ecoulement en double phase gaz-liquide. L'ecoulement est du type annulaire disperse, obtenu par injection d'une faible quantite de liquide dans un ecoulement gazeux en regime turbulent. Les experiences de transfert thermique sont menees sans vaporisation de la phase liquide. On note une amelioration sensible du coefficient de transfert thermique dans un tel ecoulement par rapport a un ecoulement de gaz seul ou de liquide seul. L'augmentation est de l'ordre de 20 par rapport au gaz seul si on opere a meme nombre de REYNOLDS du gaz, de l'ordre de 8 si on opere a meme debit massique total. Une etude hydrodynamique rapide de l'ecoulement permet de connaitre la structure originale de l'ecoulement, puis de prevoir par une theorie simplifiee le phenomene thermique observe. (auteurs)

  4. Determination of hexachlorocyclohexane pesticide residues in wool fat by a combined high-performance liquid chromatographic-gas-liquid chromatographic method

    International Nuclear Information System (INIS)

    Ali, S.L.

    1978-01-01

    Beta- and gamma-hexachlorocyclohexane residues were determined in twelve wool fat samples by using a combined high-performance liquid chromatographic (HPLC)-gas-liquid chromatographic (GLC) method. After extraction and chromatographic clean-up on a silca-gel column, the sample was further purified by HPLC on a reversed-phase C-18 column with methanol as the mobile phase. The final determination was effected by GLC with a 1-mCi nickel-63 electron-capture detector. The analytical method was checked by addition of carbon-14-labelled lindane and measurement of the radioactivity in a liquid scintillation counter. (Auth.)

  5. Laser ablated copper plasmas in liquid and gas ambient

    Science.gov (United States)

    Kumar, Bhupesh; Thareja, Raj K.

    2013-05-01

    The dynamics of copper ablated plasma plumes generated using laser ablation of copper targets in both liquid (de-ionized water) and gas (air) ambients is reported. Using time and space resolved visible emission spectroscopy (450-650 nm), the plasma plumes parameters are investigated. The electron density (ne) determined using Stark broadening of the Cu I (3d104d1 2D3/2-3d104p1 2P3/2 at 521.8 nm) line is estimated and compared for both plasma plumes. The electron temperature (Te) was estimated using the relative line emission intensities of the neutral copper transitions. Field emission scanning electron microscopy and energy dispersive x-ray spectral analysis of the ablated copper surface indicated abundance of spherical nanoparticles in liquid while those in air are amalgamates of irregular shapes. The nanoparticles suspended in the confining liquid form aggregates and exhibit a surface plasmon resonance at ˜590 nm.

  6. Modeling of Liquid Steel/Slag/Argon Gas Multiphase Flow During Tundish Open Eye Formation in a Two-Strand Tundish

    Science.gov (United States)

    Chatterjee, Saikat; Li, Donghui; Chattopadhyay, Kinnor

    2018-04-01

    Multiphase flows are frequently encountered in metallurgical operations. One of the most effective ways to understand these processes is by flow modeling. The process of tundish open eye (TOE) formation involves three-phase interaction between liquid steel, slag, and argon gas. The two-phase interaction involving argon gas bubbles and liquid steel can be modeled relatively easily using the discrete phase modeling technique. However, the effect of an upper slag layer cannot be captured using this approach. The presence of an upper buoyant phase can have a major effect on the behavior of TOEs. Hence, a multiphase model, including three phases, viz. liquid steel, slag, and argon gas, in a two-strand slab caster tundish, was developed to study the formation and evolution of TOEs. The volume of fluid model was used to track the interphase between liquid steel and slag phases, while the discrete phase model was used to trace the movement of the argon gas bubbles in liquid steel. The variation in the TOE areas with different amounts of aspirated argon gas was examined in the presence of an overlying slag phase. The mathematical model predictions were compared against steel plant measurements.

  7. Visualization for gas-liquid two-phase flow using wire mesh tomography

    International Nuclear Information System (INIS)

    Motegi, Yuichi; Wanjiraniran, Weerin; Kikura, Hiroshige; Aritomi, Masanori; Yamauchi, Toyoaki

    2003-01-01

    Wire Mesh Tomography (WMT), which is system to measure two-phase flow, has been developed in our laboratory. Measurement principle of WMT is detecting conductivity difference between gas and liquid. WMT measures void fraction as raw date, and calculates gas velocity and bubble volume etc. In this paper, this measurement technique was applied to vertical circular pipe of 50 mm diameter and about 7 m heights. New Wire Mesh Sensor (WMS), which is measurement part of WMT, for circular pipe, have been made. When experiment was performed, superficial gas and water velocity. The effect of each flow parameter was found for void fraction, true gas velocity and bubble volume and the results was in good agreement with the past research, qualitatively. (author)

  8. High ionic liquid content polymeric gel membranes: Preparation and performance

    Czech Academy of Sciences Publication Activity Database

    Jansen, J. C.; Friess, K.; Clarizia, G.; Schauer, Jan; Izák, Pavel

    2011-01-01

    Roč. 44, č. 1 (2011), s. 39-45 ISSN 0024-9297 R&D Projects: GA ČR GA203/08/0465; GA ČR GAP106/10/1194 Institutional research plan: CEZ:AV0Z40500505; CEZ:AV0Z40720504 Keywords : ionic liquid membrane * gas separation membrane * 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide Subject RIV: CD - Macromolecular Chemistry Impact factor: 5.167, year: 2011

  9. Studies of Two-Phase Gas-Liquid Flow in Microgravity. Ph.D. Thesis, Dec. 1994

    Science.gov (United States)

    Bousman, William Scott

    1995-01-01

    Two-phase gas-liquid flows are expected to occur in many future space operations. Due to a lack of buoyancy in the microgravity environment, two-phase flows are known to behave differently than those in earth gravity. Despite these concerns, little research has been conducted on microgravity two-phase flow and the current understanding is poor. This dissertation describes an experimental and modeling study of the characteristics of two-phase flows in microgravity. An experiment was operated onboard NASA aircraft capable of producing short periods of microgravity. In addition to high speed photographs of the flows, electronic measurements of void fraction, liquid film thickness, bubble and wave velocity, pressure drop and wall shear stress were made for a wide range of liquid and gas flow rates. The effects of liquid viscosity, surface tension and tube diameter on the behavior of these flows were also assessed. From the data collected, maps showing the occurrence of various flow patterns as a function of gas and liquid flow rates were constructed. Earth gravity two-phase flow models were compared to the results of the microgravity experiments and in some cases modified. Models were developed to predict the transitions on the flow pattern maps. Three flow patterns, bubble, slug and annular flow, were observed in microgravity. These patterns were found to occur in distinct regions of the gas-liquid flow rate parameter space. The effect of liquid viscosity, surface tension and tube diameter on the location of the boundaries of these regions was small. Void fraction and Weber number transition criteria both produced reasonable transition models. Void fraction and bubble velocity for bubble and slug flows were found to be well described by the Drift-Flux model used to describe such flows in earth gravity. Pressure drop modeling by the homogeneous flow model was inconclusive for bubble and slug flows. Annular flows were found to be complex systems of ring-like waves and a

  10. Thermodynamic models to predict gas-liquid solubilities in the methanol synthesis, the methanol-higher alcohol synthesis, and the Fischer-Tropsch synthesis via gas-slurry processes

    NARCIS (Netherlands)

    Breman, B.B; Beenackers, A.A C M

    1996-01-01

    Various thermodynamic models were tested concerning their applicability to predict gas-liquid solubilities, relevant for synthesis gas conversion to methanol, higher alcohols, and hydrocarbons via gas-slurry processes. Without any parameter optimization the group contribution equation of state

  11. Hazard categorization of 100 K West fuel canister gas and liquid sampling

    International Nuclear Information System (INIS)

    Alwardt, L.D.

    1994-01-01

    This report documents the determination that the activities associated with the 100 K West fuel canister gas and liquid sampling are classified as Hazard Category Other (consequences are below criteria for Category 3)

  12. Influence of oxygen gas on characteristics of self-organized luminous pattern formation observed in an atmospheric dc glow discharge using a liquid electrode

    International Nuclear Information System (INIS)

    Shirai, Naoki; Uchida, Satoshi; Tochikubo, Fumiyoshi

    2014-01-01

    Self-organized luminous pattern formation is observed in the liquid surface of an atmospheric dc glow discharge using a liquid electrode with a miniature helium flow. The factors affecting pattern formation are the gap length, discharge current, helium mass flow rate and polarity. The pattern shape depends on the conductivity and temperature of the liquid electrode. A variety of patterns were observed by changing the conductivity and temperature of the liquid. We clarified that the self-organized pattern formation depends on the amount of electronegative gas, such as oxygen, in the gas in the electrode gap. When an oxygen gas flow was fed to the liquid surface from the outside in an obliquely downward direction, namely, the amount of oxygen gas on the liquid surface was increased locally, self-organized pattern formation was observed in the region with the increased amount of oxygen gas. When the amount of oxygen in the gas in the gap was changed by using a sheath flow system, the appearance of the pattern changed. The presence of oxygen gas strongly affected the self-organized pattern formation of the atmospheric dc discharge using a liquid anode. (paper)

  13. Gas-liquid flow splitting in T-junction with inclined lateral arm

    Science.gov (United States)

    Yang, Le-le; Liu, Shuo; Li, Hua; Zhang, Jian; Wu, Ying-xiang; Xu, Jing-yu

    2018-02-01

    This paper studies the gas-liquid flow splitting in T-junction with inclined lateral arm. The separation mechanism of the T-junction is related to the pressure distribution in the T-junction. It is shown that the separation efficiency strongly depends on the inclination angle, when the angle ranges from 0° to 30°, while not so strongly for angles in the range from 30° to 90° Increasing the number of connecting tubes is helpful for the gas-liquid separation, and under the present test conditions, with four connecting tubes, a good separation performance can be achieved. Accordingly, a multi-tube Y-junction separator with four connecting tubes is designed for the experimental investigation. A good agreement between the simulated and measured data shows that there is an optimal split ratio to achieve the best performance for the multi-tube Y-junction separator.

  14. Industrial aspects of gas-liquid two-phase flow

    International Nuclear Information System (INIS)

    Hewitt, G.F.

    1977-01-01

    The lecture begins by reviewing the various types of plant in which two phase flow occurs. Specifically, boiling plant, condensing plant and pipelines are reviewed, and the various two phase flow problems occurring in them are described. Of course, many other kinds of chemical engineering plant involve two phase flow, but are somewhat outside the scope of this lecture. This would include distillation columns, vapor-liquid separators, absorption towers etc. Other areas of industrial two phase flow which have been omitted for space reasons from this lecture are those concerned with gas/solids, liquid/solid and liquid/liquid flows. There then follows a description of some of the two phase flow processes which are relevant in industrial equipment and where special problems occur. The topics chosen are as follows: (1) pressure drop; (2) horizontal tubes - separation effects non-uniformites in heat transfer coefficient, effect of bends on dryout; (3) multicomponent mixtures - effects in pool boiling, mass transfer effects in condensation and Marangoni effects; (4) flow distribution - manifold problems in single phase flow, separation effects at a single T-junction in two phase flow and distribution in manifolds in two phase flow; (5) instability - oscillatory instability, special forms of instability in cryogenic systems; (6) nucleate boiling - effect of variability of surface, unresolved problems in forced convective nucleate boiling; and (7) shell side flows - flow patterns, cross flow boiling, condensation in cross flow

  15. Quality control of residual solvents in [18F]FDG preparations by gas chromatography

    International Nuclear Information System (INIS)

    Lee, Hak Jeong; Jeong, Jae Min; Lee, Yun Sang; Kim, Hyung Woo; Chang, Young Soo; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul

    2007-01-01

    Analysis of volatile organic solvents in 2-deoxy-2[ 18 F] fluoro-D-glucose ([ 18 F]FDG) preparations was performed by gas chromatography (GC), in accordance with USP. Analyses were carried out on a Hewlett-Packard 6890 gas chromatography equipped with an FID. We determined the amounts of ethanol and acetonitrile on every batch of our routine [ 18 F]FDG preparations, ranging between 5000 ppm and 100 ppm. In our routine preparation of [ 18 F]FDG, the amount of acetonitrile and ethanol in the final product were well below the maximum allowable limit described in the USP. Our [ 18 F]FDG preparations were in accordance with the suggested USP maximum allowable levels of the quality control analysis of volatile organic compounds

  16. Acoustic probe for solid-gas-liquid suspensions. 1998 annual progress report

    International Nuclear Information System (INIS)

    Greenwood, M.S.; Sangani, A.S.; Tavlarides, L.L.

    1998-01-01

    'The proposed research will develop an acoustic probe for monitoring particle size and volume fraction in slurries in the absence and presence of gas. The goals are to commission and verify the probe components and system operation, develop theory for the forward and inverse problems for acoustic wave propagation through a three phase medium, and experimentally verify the theoretical analysis. The acoustic probe will permit measurement of solid content in gas-liquid-solid waste slurries in tanks across the DOE complex.'

  17. A portable liquid crystal-based polarized light system for the detection of organophosphorus nerve gas

    Science.gov (United States)

    He, Feng Jie; Liu, Hui Long; Chen, Long Cong; Xiong, Xing Liang

    2018-03-01

    Liquid crystal (LC)-based sensors have the advantageous properties of being fast, sensitive, and label-free, the results of which can be accessed directly only through the naked eye. However, the inherent disadvantages possessed by LC sensors, such as relying heavily on polarizing microscopes and the difficulty to quantify, have limited the possibility of field applications. Herein, we have addressed these issues by constructing a portable polarized detection system with constant temperature control. This system is mainly composed of four parts: the LC cell, the optics unit, the automatic temperature control unit, and the image processing unit. The LC cell was based on the ordering transitions of LCs in the presence of analytes. The optics unit based on the imaging principle of LCs was designed to substitute the polarizing microscope for the real-time observation. The image processing unit is expected to quantify the concentration of analytes. The results have shown that the presented system can detect dimethyl methyl phosphonate (a stimulant for organophosphorus nerve gas) within 25 s, and the limit of detection is about 10 ppb. In all, our portable system has potential in field applications.

  18. The self limiting effect of hydrogen cluster in gas jet under liquid nitrogen temperature

    International Nuclear Information System (INIS)

    Han Jifeng; Yang Chaowen; Miao Jingwei; Fu Pengtao; Luo Xiaobing; Shi Miangong

    2010-01-01

    The generation of hydrogen clusters in gas jet is tested using the Rayleigh scattering method under liquid nitrogen temperature of 79 K. The self limiting effect of hydrogen cluster is studied and it is found that the cluster formation is greatly affected by the number of expanded molecules. The well designed liquid nitrogen cold trap ensured that the hydrogen cluster would keep maximum size for maximum 15 ms during one gas jet. The scattered light intensity exhibits a power scaling on the backing pressure ranging from 5 to 48 bar with the power value of 4.1.

  19. Third-order gas-liquid phase transition and the nature of Andrews critical point

    Directory of Open Access Journals (Sweden)

    Tian Ma

    2011-12-01

    Full Text Available The main objective of this article is to study the nature of the Andrews critical point in the gas-liquid transition in a physical-vapor transport (PVT system. A dynamical model, consistent with the van der Waals equation near the Andrews critical point, is derived. With this model, we deduce two physical parameters, which interact exactly at the Andrews critical point, and which dictate the dynamic transition behavior near the Andrews critical point. In particular, it is shown that 1 the gas-liquid co-existence curve can be extended beyond the Andrews critical point, and 2 the transition is first order before the critical point, second-order at the critical point, and third order beyond the Andrews critical point. This clearly explains why it is hard to observe the gas-liquid phase transition beyond the Andrews critical point. Furthermore, the analysis leads naturally the introduction of a general asymmetry principle of fluctuations and the preferred transition mechanism for a thermodynamic system. The theoretical results derived in this article are in agreement with the experimental results obtained in (K. Nishikawa and T. Morita, Fluid behavior at supercritical states studied by small-angle X-ray scattering, Journal of Supercritical Fluid, 13 (1998, pp. 143-148. Also, the derived second-order transition at the critical point is consistent with the result obtained in (M. Fisher, Specific heat of a gas near the critical point, Physical Review, 136:6A (1964, pp. A1599-A1604.

  20. A review on measuring methods of gas-liquid flow rates

    International Nuclear Information System (INIS)

    Minemura, Kiyoshi; Yamashita, Masato

    2000-01-01

    This paper presents a review on the state of current measuring techniques for gas-liquid multiphase flow rates. After briefly discussing the basic idea on measuring methods for single-phase and two-phase flows, existing methods for the two-phase flow rates are classified into several types, that is, with or without a homogenizing device, single or combined method of several techniques, with intrusive or non-intrusive sensors, and physical or software method. Each methods are comparatively reviewed in view of measuring accuracy and manageability. Its scope also contains the techniques developed for petroleum-gas-water flow rates. (author)

  1. Pore-scale analysis of the minimum liquid film thickness around elongated bubbles in confined gas-liquid flows

    Science.gov (United States)

    Magnini, M.; Beisel, A. M.; Ferrari, A.; Thome, J. R.

    2017-11-01

    The fluid mechanics of elongated bubbles in confined gas-liquid flows in micro-geometries is important in pore-scale flow processes for enhanced oil recovery and mobilization of colloids in unsaturated soil. The efficiency of such processes is traditionally related to the thickness of the liquid film trapped between the elongated bubble and the pore's wall, which is assumed constant. However, the surface of long bubbles presents undulations in the vicinity of the rear meniscus, which may significantly decrease the local thickness of the liquid film, thus impacting the process of interest. This study presents a systematic analysis of these undulations and the minimum film thickness induced in the range Ca = 0.001- 0.5 and Re = 0.1- 2000 . Pore-scale Computational Fluid Dynamics (CFD) simulations are performed with a self-improved version of the opensource solver ESI OpenFOAM which is based on a Volume of Fluid method to track the gas-liquid interface. A lubrication model based on the extension of the classical axisymmetric Bretherton theory is utilized to better understand the CFD results. The profiles of the rear meniscus of the bubble obtained with the lubrication model agree fairly well with those extracted from the CFD simulations. This study shows that the Weber number of the flow, We = Ca Re , is the parameter that best describes the dynamics of the interfacial waves. When We 0.1, a larger number of wave crests becomes evident on the surface of the rear meniscus of the bubble. The liquid film thickness at the crests of the undulations thins considerably as the Reynolds number is increased, down to less than 60% of the value measured in the flat film region. This may significantly influence important environmental processes, such as the detachment and mobilization of micron-sized pollutants and pathogenic micro-organisms adhering at the pore's wall in unsaturated soil.

  2. Csaba Horváth and preparative liquid chromatography.

    Science.gov (United States)

    Guiochon, Georges

    2005-06-24

    Few chromatographers have been interested in furthering preparative liquid chromatography. The pioneers, Tswett, Kuhn and Lederer, A.J.P. Martin, Tiselius, isolated fractions but as an intermediate step in the analysis of their samples. The progress in electronics and sensors, and in their miniaturization has lead to the paradoxical situation that the analysts never see the transient pure fractions that their detector quantitates. Yet, over the last 25 years, preparative liquid chromatography has become an important industrial process for the separation, the extraction, and/or the purification of many pharmaceuticals or pharmaceutical intermediates, including pure enantiomers, purified peptides and proteins, compounds that are manufactured at the relatively large industrial scale of a few kilograms to several hundred tons per year. This development that has strongly affected the modem pharmaceutical industry is mainly due to the pioneering work of Csaba Horváth. His work in preparative HPLC was critical at both the practical and the theoretical levels. He was the first scientist in modem times to pay serious attention to the relationships between the curvature of the equilibrium isotherms, the competitive nature of nonlinear isotherms, and the chromatographic band profiles of complex mixtures. The thermodynamics of multi-component phase equilibria and mass transfer kinetics in chromatography attracted his interest and were the focus of ground-breaking contributions. He investigated displacement chromatography, an old method invented by Tiselius that Csaba was first to implement in HPLC. This choice was explained by the essential characteristic of displacement chromatography, in that it delivers fractions that can be far more concentrated than the feed. Remarkably, once the basics of nonlinear chromatography had been mastered in his group, most of the applications that were studied by his coworkers dealt with peptides of various sizes and with proteins. Thus, all

  3. Distributed automatic control of technological processes in conditions of weightlessness

    Science.gov (United States)

    Kukhtenko, A. I.; Merkulov, V. I.; Samoylenko, Y. I.; Ladikov-Royev, Y. P.

    1986-01-01

    Some problems associated with the automatic control of liquid metal and plasma systems under conditions of weightlessness are examined, with particular reference to the problem of stability of liquid equilibrium configurations. The theoretical fundamentals of automatic control of processes in electrically conducting continuous media are outlined, and means of using electromagnetic fields for simulating technological processes in a space environment are discussed.

  4. Automatic Carbon Dioxide-Methane Gas Sensor Based on the Solubility of Gases in Water

    Directory of Open Access Journals (Sweden)

    Raúl O. Cadena-Pereda

    2012-08-01

    Full Text Available Biogas methane content is a relevant variable in anaerobic digestion processing where knowledge of process kinetics or an early indicator of digester failure is needed. The contribution of this work is the development of a novel, simple and low cost automatic carbon dioxide-methane gas sensor based on the solubility of gases in water as the precursor of a sensor for biogas quality monitoring. The device described in this work was used for determining the composition of binary mixtures, such as carbon dioxide-methane, in the range of 0–100%. The design and implementation of a digital signal processor and control system into a low-cost Field Programmable Gate Array (FPGA platform has permitted the successful application of data acquisition, data distribution and digital data processing, making the construction of a standalone carbon dioxide-methane gas sensor possible.

  5. Automatic carbon dioxide-methane gas sensor based on the solubility of gases in water.

    Science.gov (United States)

    Cadena-Pereda, Raúl O; Rivera-Muñoz, Eric M; Herrera-Ruiz, Gilberto; Gomez-Melendez, Domingo J; Anaya-Rivera, Ely K

    2012-01-01

    Biogas methane content is a relevant variable in anaerobic digestion processing where knowledge of process kinetics or an early indicator of digester failure is needed. The contribution of this work is the development of a novel, simple and low cost automatic carbon dioxide-methane gas sensor based on the solubility of gases in water as the precursor of a sensor for biogas quality monitoring. The device described in this work was used for determining the composition of binary mixtures, such as carbon dioxide-methane, in the range of 0-100%. The design and implementation of a digital signal processor and control system into a low-cost Field Programmable Gate Array (FPGA) platform has permitted the successful application of data acquisition, data distribution and digital data processing, making the construction of a standalone carbon dioxide-methane gas sensor possible.

  6. Two-Phase Gas-Liquid Flow Structure Characteristics under Periodic Cross Forces Action

    Directory of Open Access Journals (Sweden)

    V. V. Perevezentsev

    2015-01-01

    Full Text Available The article presents a study of two-phase gas-liquid flow under the action of periodic cross forces. The work objective is to obtain experimental data for further analysis and have structure characteristics of the two-phase flow movement. For research, to obtain data without disturbing effect on the flow were used optic PIV (Particle Image Visualization methods because of their noninvasiveness. The cross forces influence was provided by an experimental stand design to change the angular amplitudes and the periods of channel movement cycle with two-phase flow. In the range of volume gas rates was shown a water flow rate versus the inclination angle of immovable riser section and the characteristic angular amplitudes and periods of riser section inclination cycle under periodic cross forces. Data on distribution of average water velocity in twophase flow in abovementioned cases were also obtained. These data allowed us to draw a conclusion that a velocity distribution depends on the angular amplitude and on the period of the riser section roll cycle. This article belongs to publications, which study two-phase flows with no disturbing effect on them. Obtained data give an insight into understanding a pattern of twophase gas-liquid flow under the action of periodic cross forces and can be used to verify the mathematical models of the CFD thermo-hydraulic codes. In the future, the work development expects taking measurements with more frequent interval in the ranges of angular amplitudes and periods of the channel movement cycle and create a mathematical model to show the action of periodic cross forces on two-phase gas-liquid flow.

  7. A novel method for the preparation of electrophoretic display microcapsules

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiao-Meng; He, Jing; Liu, Sheng-Yun [State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing 100029 (China); Chen, Jian-Feng [State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing 100029 (China); Research Center of the Ministry of Education for High Gravity Engineering and Technology, Beijing University of Chemical Technology, Beijing 100029 (China); Le, Yuan, E-mail: leyuan@mail.buct.edu.cn [State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing 100029 (China)

    2014-07-01

    Highlights: • The electrophoretic display microcapsules were prepared by coaxial jet method aided by gas spray. • The positions of inner tube, liquid and gas flow rate of the process were investigated. • The size and shell thickness of the prepared microcapsules were controllable. • The prepared microcapsules had high coating ratio and exhibit reversible response to DC field. - Abstract: The narrow distributed electrophoretic display microcapsules containing electrophoretic ink were prepared using coaxial jet method aided by gas spray. Experimental results showed the size and shell thickness of the microcapsules could be controlled by adjusting flow rates of core and shell fluids as well as gas. The as-prepared white and red microcapsules, with average size of 100 and 200 μm respectively, had high coating ratio (above 90%) and exhibited reversible response to DC electric field. Compared with the approach of other microencapsulation methods, the new technique not only has a simple procedure but also provides a more effective way of size control. This novel method is expected to prepare microcapsules with potential application in the fields of electronic paper and other material science.

  8. Automatic isotope gas analysis of tritium labelled organic materials Pt. 3

    International Nuclear Information System (INIS)

    Gacs, I.; Mlinko, S.; Payer, K.; Otvos, L.; Banfi, D.; Palagyi, T.

    1978-01-01

    An isotope analytical procedure and an automatic instrument developed for the determination of tritium in organic compounds and biological materials by internal gas counting are described. The sample is burnt in a stream of oxygen and the combustion products including water vapour carrying the tritium are led onto a column of molecular sieve-5A heated to 550 deg C. Tritium is retained temporarily on the column, then transferred into a stream of hydrogen by isotope exchange. After addition of butane, the tritiated hydrogen is led into an internal detector and enclosed there for radioactivity measurement. The procedure, providing quantitative recovery, is completed in five minutes. It is free of memory effect and suitable for the determination of tritium in a wide range of organic compounds and samples of biological origin. (author)

  9. Studying the instantaneous velocity field in gas-sheared liquid films in a horizontal duct

    Science.gov (United States)

    Vasques, Joao; Tokarev, Mikhail; Cherdantsev, Andrey; Hann, David; Hewakandamby, Buddhika; Azzopardi, Barry

    2016-11-01

    In annular flow, the experimental validation of the basic assumptions on the liquid velocity profile is vital for developing theoretical models of the flow. However, the study of local velocity of liquid in gas-sheared films has proven to be a challenging task due to the highly curved and disturbed moving interface of the phases, small scale of the area of interrogation, high velocity gradients and irregular character of the flow. This study reports on different optical configurations and interface-tracking methods employed in a horizontal duct in order to obtain high-resolution particle image velocimetry (PIV) data in such types of complex flows. The experimental envelope includes successful measurements in 2D and 3D waves regimes, up to the disturbance wave regime. Preliminary data show the presence of complex structures in the liquid phase, which includes re-circulation areas below the liquid interface due to the gas-shearing action, together with non-uniform transverse movements of the liquid phase close to the wall due to the presence of 3D waves at the interface. With the aid of the moving interface-tracking, PIV, time-resolved particle-tracking velocimetry and vorticity measurements were performed.

  10. Atomizing industrial gas-liquid flows – Development of an efficient hybrid VOF-LPT numerical framework

    International Nuclear Information System (INIS)

    Ström, Henrik; Sasic, Srdjan; Holm-Christensen, Olav; Shah, Louise Jivan

    2016-01-01

    Highlights: • Modelling of turbulent atomizing gas-liquid flows in real industrial devices. • A combined VOF-LPT framework with statistical coupling. • Regions of separated and dispersed multiphase flow treated simultaneously. • Statistical model based on a limited amount of highly resolved VOF data. - Abstract: Atomizing gas-liquid flows are used in industrial applications where high interphase heat and mass transfer rates and good mixing are of primary importance. Today, there is no single mathematical framework available to predict the entire liquid breakup process at an acceptable computational cost for a typical problem of industrial size. In this work, we develop a volume-of-fluid (VOF) framework that is combined with Lagrangian particle tracking (LPT) to take advantage of the respective strengths of these two approaches. The two frameworks are coupled via a statistical model that enables a transition from the VOF to the LPT formulation using input data about the primary breakup process obtained from detailed VOF simulations in dedicated switching zones. LPT-to-VOF transitions are handled directly by analyzing the proximity of LPT parcels to larger VOF structures. The combined framework is specifically designed to accommodate situations where atomization occurs in several locations simultaneously and when separated and dispersed turbulent gas-liquid flows co-exist in the same industrial unit. The procedure in which the statistical model is derived is presented and discussed, its performance is verified and the computational efficiency of the combined VOF-LPT model is assessed. Finally, the application of the coupled framework to the simulation of an industrial gas-liquid mixer with four separate atomization regions is presented.

  11. Liquid film characterization in horizontal, annular, two-phase, gas-liquid flow using time-resolved laser-induced fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Farias, P.S.C.; Martins, F.J.W.A.; Azevedo, L.F.A. [PUC-Rio, Department of Mechanical Engineering, Rio de Janeiro (Brazil); Sampaio, L.E.B. [LMTA/PGMEC, UFF, Department of Mechanical Engineering, Laboratory of Theoretical and Applied Mechanics, Rio de Janeiro (Brazil); Serfaty, R. [Petrobras R and D Center, Rio de Janeiro (Brazil)

    2012-03-15

    A non-intrusive optical technique was developed to provide time-resolved longitudinal and cross-sectional images of the liquid film in horizontal annular pipe flow of air and water, revealing the interfacial wave behavior. Quantitative information on the liquid film dynamics was extracted from the time-resolved images. The planar laser-induced fluorescence technique was utilized to allow for optical separation of the light emitted by the film from that scattered by the air-water interface. The visualization test section was fabricated from a tube presenting nearly the same refractive index as water, which allowed the visualization of the liquid film at regions very close to the pipe wall. Longitudinal images of the liquid film were captured using a high-frame-rate digital video camera synchronized with a high-repetition-rate laser. An image processing algorithm was developed to automatically detect the position of the air-water interface in each image frame. The thickness of the liquid film was measured at two axial stations in each processed image frame, providing time history records of the film thickness at two different positions. Wave frequency information was obtained by analyzing the time-dependent signals of film thickness for each of the two axial positions recorded. Wave velocities were measured by cross-correlating the amplitude signals from the two axial positions. For the film cross-section observations, two high-speed digital video cameras were used in a stereoscopic arrangement. Comparisons with results from different techniques available in literature indicate that the technique developed presents equivalent accuracy in measuring the liquid film properties. Time-resolved images of longitudinal and cross-section views of the film were recorded, which constitute valuable information provided by the technique implemented. (orig.)

  12. Colloidal gas-liquid condensation of polystyrene latex particles with intermediate kappa a values (5 to 160, a > kappa(-1)).

    Science.gov (United States)

    Ishikawa, Masamichi; Kitano, Ryota

    2010-02-16

    Polystyrene latex particles showed gas-liquid condensation under the conditions of large particle radius (a > kappa(-1)) and intermediate kappa a, where kappa is the Debye-Hückel parameter and a is the particle radius. The particles were dissolved in deionized water containing ethanol from 0 to 77 vol %, settled to the bottom of the glass plate within 1 h, and then laterally moved toward the center of a cell over a 20 h period in reaching a state of equilibrium condensation. All of the suspensions that were 1 and 3 microm in diameter and 0.01-0.20 vol % in concentration realized similar gas-liquid condensation with clear gas-liquid boundaries. In 50 vol % ethanol solvent, additional ethanol was added to enhance the sedimentation force so as to restrict the particles in a monoparticle layer thickness. The coexistence of gas-liquid-solid (crystalline solid) was microscopically recognized from the periphery to the center of the condensates. A phase diagram of the gas-liquid condensation was created as a function of KCl concentration at a particle diameter of 3 microm, 0.10 vol % concentration, and 50:50 water/ethanol solvent at room temperature. The miscibility gap was observed in the concentration range from 1 to 250 microM. There was an upper limit of salt concentration where the phase separation disappeared, showing nearly critical behavior of macroscopic density fluctuation from 250 microM to 1 mM. These results add new experimental evidence to the existence of colloidal gas-liquid condensation and specify conditions of like-charge attraction between particles.

  13. Detector for the liquid carried over in a gas; Detecteur d'entrainement de liquide dans un gaz

    Energy Technology Data Exchange (ETDEWEB)

    Delisle, J P; Eperonnat, P; Lions, N [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1965-07-01

    This report describes an optical detector for the detection of a liquid carried over by a gas. The device is sensitive to a cumulated quantity of liquid equal to a few cubic millimetres and is capable of operating an alarm from a distance. The prototype was constructed and tested as detector for the oil leaking in the argon compressed by a diaphragm compressor. A patent for this apparatus under the number: P.V.954.703, has been deposited on 22.11.1963. (authors) [French] Ce rapport decrit un detecteur optique d'entrainement de liquide dans un gaz, sensible a une quantite cumulee de liquide entraine egale a quelques millimetres cubes. L'appareil peut actionner une alarme a distance. Le prototype a ete construit et essaye comme detecteur de fuites d'huile dans l'argon refoule par un compresseur a membranes. Une demande de brevet a ete deposee pour cet appareil sous le numero: P.V.954.703, le 22.11.1963. (auteur)

  14. Modern methods of sample preparation for GC analysis

    NARCIS (Netherlands)

    de Koning, S.; Janssen, H.-G.; Brinkman, U.A.Th.

    2009-01-01

    Today, a wide variety of techniques is available for the preparation of (semi-) solid, liquid and gaseous samples, prior to their instrumental analysis by means of capillary gas chromatography (GC) or, increasingly, comprehensive two-dimensional GC (GC × GC). In the past two decades, a large number

  15. Automatic semi-continuous accumulation chamber for diffuse gas emissions monitoring in volcanic and non-volcanic areas

    Science.gov (United States)

    Lelli, Matteo; Raco, Brunella; Norelli, Francesco; Virgili, Giorgio; Continanza, Davide

    2016-04-01

    Since various decades the accumulation chamber method is intensively used in monitoring activities of diffuse gas emissions in volcanic areas. Although some improvements have been performed in terms of sensitivity and reproducibility of the detectors, the equipment used for measurement of gas emissions temporal variation usually requires expensive and bulky equipment. The unit described in this work is a low cost, easy to install-and-manage instrument that will make possible the creation of low-cost monitoring networks. The Non-Dispersive Infrared detector used has a concentration range of 0-5% CO2, but the substitution with other detector (range 0-5000 ppm) is possible and very easy. Power supply unit has a 12V, 7Ah battery, which is recharged by a 35W solar panel (equipped with charge regulator). The control unit contains a custom programmed CPU and the remote transmission is assured by a GPRS modem. The chamber is activated by DataLogger unit, using a linear actuator between the closed position (sampling) and closed position (idle). A probe for the measure of soil temperature, soil electrical conductivity, soil volumetric water content, air pressure and air temperature is assembled on the device, which is already arranged for the connection of others external sensors, including an automatic weather station. The automatic station has been tested on the field at Lipari island (Sicily, Italy) during a period of three months, performing CO2 flux measurement (and also weather parameters), each 1 hour. The possibility to measure in semi-continuous mode, and at the same time, the gas fluxes from soil and many external parameters, helps the time series analysis aimed to the identification of gas flux anomalies due to variations in deep system (e.g. onset of volcanic crises) from those triggered by external conditions.

  16. Dynamic simulation of dispersed gas-liquid two-phase flow using a discrete bubble model.

    NARCIS (Netherlands)

    Delnoij, E.; Lammers, F.A.; Kuipers, J.A.M.; van Swaaij, Willibrordus Petrus Maria

    1997-01-01

    In this paper a detailed hydrodynamic model for gas-liquid two-phase flow will be presented. The model is based on a mixed Eulerian-Lagrangian approach and describes the time-dependent two-dimensional motion of small, spherical gas bubbles in a bubble column operating in the homogeneous regime. The

  17. Studying gas-sheared liquid film in horizontal rectangular duct with laser-induced fluorescence technique

    Science.gov (United States)

    Cherdantsev, Andrey; Hann, David; Azzopardi, Barry

    2013-11-01

    High-speed LIF-technique is applied to study gas-sheared liquid film in horizontal rectangular duct with 161 mm width. Instantaneous distributions of film thickness resolved in both longitudinal and transverse coordinates were obtained with a frequency of 10 kHz and spatial resolution from 0.125 mm to 0.04 mm. Processes of generation of fast and slow ripples by disturbance waves are the same as described in literature for downwards annular pipe flow. Disturbance waves are often localized by transverse coordinate and may have curved or slanted fronts. Fast ripples, covering disturbance waves, are typically horseshoe-shaped and placed in staggered order. Their characteristic transverse size is of order 1 cm and it decreases with gas velocity. Entrainment of liquid from film surface can also be visualized. Mechanisms of ripple disruption, known as ``bag break-up'' and ``ligament break-up,'' were observed. Both mechanisms may occur on the same disturbance waves. Various scenarios of droplet deposition on the liquid film are observed, including the impact, slow sinking and bouncing, characterized by different outcome of secondary droplets or entrapped bubbles. Number and size of bubbles increase greatly inside the disturbance waves. Both quantities increase with gas and liquid flow rates. EPSRC Programme Grant MEMPHIS (EP/K003976/1), and Roll-Royce UTC (Nottingham, for access to flow facility).

  18. Optimal design issues of a gas-to-liquid process

    Energy Technology Data Exchange (ETDEWEB)

    Rafiee, Ahmad

    2012-07-01

    Interests in Fischer-Tropsch (FT) synthesis is increasing rapidly due to the recent improvements of the technology, clean-burning fuels (low sulphur, low aromatics) derived from the FT process and the realization that the process can be used to monetize stranded natural gas resources. The economy of GTL plants depends very much on the natural gas price and there is a strong incentive to reduce the investment cost and in addition there is a need to improve energy efficiency and carbon efficiency. A model is constructed based on the available information in open literature. This model is used to simulate the GTL process with UNISIM DESIGN process simulator. In the FT reactor with cobalt based catalyst, Co2 is inert and will accumulate in the system. Five placements of Co2 removal unit in the GTL process are evaluated from an economical point of view. For each alternative, the process is optimized with respect to steam to carbon ratio, purge ratio of light ends, amount of tail gas recycled to syngas and FT units, reactor volume, and Co2 recovery. The results show that carbon and energy efficiencies and the annual net cash flow of the process with or without Co2 removal unit are not significantly different and there is not much to gain by removing Co2 from the process. It is optimal to recycle about 97 % of the light ends to the process (mainly to the FT unit) to obtain higher conversion of CO and H2 in the reactor. Different syngas configurations in a gas-to-liquid (GTL) plant are studied including auto-thermal reformer (ATR), combined reformer, and series arrangement of Gas Heated Reformer (GHR) and ATR. The Fischer-Tropsch (FT) reactor is based on cobalt catalyst and the degrees of freedom are; steam to carbon ratio, purge ratio of light ends, amount of tail gas recycled to synthesis gas (syngas) and Fischer-Tropsch (FT) synthesis units, and reactor volume. The production rate of liquid hydrocarbons is maximized for each syngas configuration. Installing a steam

  19. Enhanced Membrane System for Recovery of Water from Gas-Liquid Mixtures, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Gas-Liquid separation is an acute microgravity problem. Existing devices use centrifugal motion on microporous membranes to separate the two phases. Centrifugal...

  20. MATHEMATIC MODEL OF ELECTROMAGNETIC FILTRATION PROCESS OF TECHNOLOGICAL LIQUID AND GAS

    OpenAIRE

    R. A. Мouradova

    2005-01-01

    Electromagnetic filtration as a perspective method of filtration and purification of liquid and gas finds its wide application in oil and chemical industry. However absence of highly-reliable model of calculation that permits unambiguously main operational parameters of electromagnetic filtration and limits its wide application. 

  1. Local preparation and evaluation of liquid phase radioimmunoassay for determination of human serum cortisol

    International Nuclear Information System (INIS)

    Sallam, Kh.M.; El-Bayoumy, A.S.A.; Ebeid, N.H.; Michael, E.; Zein, N.; Elfarargy, Ah.F.

    2017-01-01

    The main objective of the present study was the preparation of the primary reagents of cortisol radioimmunoassay (RIA) using liquid phase double antibody technique. Three basic components were prepared and characterized to obtain valid and accurate system. These components were polyclonal anti-cortisol antibody, "1"2"5I-cortisol RIA tracer and cortisol standards. Cortisol requires conjugation step to be real antigen. Therefore, in this study this mandatory conjugation step was performed & characterized. Then formulation, optimization and validation of this liquid phase RIA technique were carried out. This assay is precise, specific and sensitive enough for using as a diagnostic tool for the adrenal cortex status. (author)

  2. Flow measurement in two-phase (gas-liquid) systems

    International Nuclear Information System (INIS)

    Hewitt, G.F.; Whalley, P.B.

    1980-01-01

    The main methods of measuring mass flow and quality in gas-liquid flows in industrial situations are reviewed. These include gamma densitometry coupled with differential pressure devices such as crifice plates, turbine flow meters and drag screens. For each method the principle of operation, and the advantages and disadvantages, are given. Some further techniques which are currently being investigated and developed for routine use are also described briefly. Finally the detailed flow measurements possible on a particular flow pattern - annular flow - is examined. (author)

  3. Research progress of SO2 removal from flue gas by functionalized ionic liquids

    Directory of Open Access Journals (Sweden)

    Xinle SHI

    2017-02-01

    Full Text Available Functionalized ionic liquids are receiving increasing attention in the field of flue gas desulfurization due to its unique physical and chemical properties. Research progress on the field of SO2 removal by ionic liquids (ILs including guanidinium-based, amines-based and ether-based ILs is summarized. Industrial application of polymerization ILs and loaded ILs to desulfurization is reviewed. Relevant suggestions on industrial application of ionic liquids based on fundamental research are put forward. The first thing is to develop functional ionic liquid for desulfurization,and thus investigate and propose its desulfurization mechanism and model; the second is to carry out the research work on immobilized ionic liquid, and explore its recycling properties, thus prolonging its service life.

  4. System and process for polarity swing assisted regeneration of gas selective capture liquids

    Science.gov (United States)

    Heldebrant, David J.; Tegrotenhuis, Ward E.; Freeman, Charles J.; Elliott, Michael L.; Koech, Phillip K.; Humble, Paul H.; Zheng, Feng; Zhang, Jian

    2017-07-18

    A polarity swing-assisted regeneration (PSAR) process is disclosed for improving the efficiency of releasing gases chemically bound to switchable ionic liquids. Regeneration of the SWIL involves addition of a quantity of non-polar organic compound as an anti-solvent to destabilize the SWIL, which aids in release of the chemically bound gas. The PSAR decreases gas loading of a SWIL at a given temperature and increases the rate of gas release compared to heating in the absence of anti-solvent.

  5. Crosslinked Polymer Ionic Liquid/Ionic Liquid Blends Prepared by Photopolymerization as Solid-State Electrolytes in Supercapacitors.

    Science.gov (United States)

    Wang, Po-Hsin; Wang, Tzong-Liu; Lin, Wen-Churng; Lin, Hung-Yin; Lee, Mei-Hwa; Yang, Chien-Hsin

    2018-04-07

    A photopolymerization method is used to prepare a mixture of polymer ionic liquid (PIL) and ionic liquid (IL). This mixture is used as a solid-state electrolyte in carbon nanoparticle (CNP)-based symmetric supercapacitors. The solid electrolyte is a binary mixture of a PIL and its corresponding IL. The PIL matrix is a cross-linked polyelectrolyte with an imidazole salt cation coupled with two anions of Br - in PIL-M-(Br) and TFSI - in PIL-M-(TFSI), respectively. The corresponding ionic liquids have imidazolium salt cation coupled with two anions of Br - and TFSI - , respectively. This study investigates the electrochemical characteristics of PILs and their corresponding IL mixtures used as a solid electrolyte in supercapacitors. Results show that a specific capacitance, maximum power density and energy density of 87 and 58 F·g - ¹, 40 and 48 kW·kg - ¹, and 107 and 59.9 Wh·kg - ¹ were achieved in supercapacitors based on (PIL-M-(Br)) and (PIL-M-(TFSI)) solid electrolytes, respectively.

  6. Gas to liquids. Fischer Tropsch: what does the future hold?

    International Nuclear Information System (INIS)

    Maisonnier, G.

    2005-01-01

    The process concerning the chemical transformation of natural gas into oil-based products (a so-called 'clean' diesel) known under the term GTL FT (Gas To Liquids - Fischer Tropsch) will turn a new page in its history with the start-up of a major unit in Qatar in 2006 Up until now only two GTL units were deployed, in the early 1990's (Moss as and Shell) without however resulting in the widespread expansion of this process. The technological breakthroughs achieved around the year 2000 combined with a favourable background context (concerning geopolitical tension, ears of oil production peaks, significant increases in the price of crude) now account for much of the interest shown in this solution. Consequently, outside Qatar, projects are also being looked at in various natural gas producing countries such as Nigeria or Algeria. It would be justified however to think that a new wave of natural gas recycling will gradually emerge as part of the global energy market. (author)

  7. Quantitative Analysis of Heavy Metals in Water Based on LIBS with an Automatic Device for Sample Preparation

    International Nuclear Information System (INIS)

    Hu Li; Zhao Nanjing; Liu Wenqing; Meng Deshuo; Fang Li; Wang Yin; Yu Yang; Ma Mingjun

    2015-01-01

    Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. (paper)

  8. Process for preparing a normal lighting and heating gas etc

    Energy Technology Data Exchange (ETDEWEB)

    Becker, J

    1910-12-11

    A process for preparing a normal lighting and heating gas from Australian bituminous shale by distillation and decomposition in the presence of water vapor is characterized by the fact that the gasification is suitably undertaken with gradual filling of a retort and with simultaneous introduction of water vapor at a temperature not exceeding 1,000/sup 0/ C. The resulting amount of gas is heated in the same or a second heated retort with freshly supplied vapor.

  9. An assessment of energy and environmental issues related to the use of gas-to-liquid fuels in transportation

    International Nuclear Information System (INIS)

    Greene, D.L.

    1999-01-01

    Recent technological advances in processes for converting natural gas into liquid fuels, combined with a growing need for cleaner, low-sulfur distillate fuel to mitigate the environmental impacts of diesel engines have raised the possibility of a substantial global gas-to-liquids (G-T-L) industry. This report examines the implications of G-T-L supply for U.S. energy security and the environment. It appears that a G-T-L industry would increase competitiveness in world liquid fuels markets, even if OPEC states are major producers of G-T-L's. Cleaner G-T-L distillates would help reduce air pollution from diesel engines. Implications for greenhouse gas (GHG) emissions could be positive or negative, depending on the sources of natural gas, their alternative uses, and the degree of sequestration that can be achieved for CO 2 emissions produced during the conversion process

  10. Hydrodynamics of gas-liquid slug flow along vertical pipes in turbulent regime-An experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Mayor, T.S.; Ferreira, V.; Pinto, A.M.F.R. [Centro de Estudos de Fenomenos de Transporte, Departamento de Engenharia Quimica, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias 4200-465 Porto (Portugal); Campos, J.B.L.M. [Centro de Estudos de Fenomenos de Transporte, Departamento de Engenharia Quimica, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias 4200-465 Porto (Portugal)], E-mail: jmc@fe.up.pt

    2008-08-15

    An experimental study on free-bubbling gas-liquid (air-water) vertical slug flow was developed using a non-intrusive image analysis technique. The flow pattern in the near-wake of the bubbles and in the main liquid between bubbles was turbulent. A single correlation for the bubble-to-bubble interaction is proposed, relating the trailing bubble velocity to the length of the liquid slug ahead of the bubble. The proposed correlation is shown to be independent of column diameter, column vertical coordinate, superficial liquid and gas velocities and the velocity and length of the leading bubble. Frequency distribution curves, averages, modes and standard deviations are reported, for distributions of bubble velocity, bubble length and liquid slug length, for each experimental condition studied. Good agreement was found between theoretical predictions and experimental results regarding the upward velocity of undisturbed bubbles, in a 0.032 m internal diameter column. A considerable discrepancy was found, though, for a 0.052 m internal diameter column. The acquired experimental data are crucial for the development and validation of a robust slug flow simulator.

  11. Hydrodynamics of gas-liquid slug flow along vertical pipes in turbulent regime-An experimental study

    International Nuclear Information System (INIS)

    Mayor, T.S.; Ferreira, V.; Pinto, A.M.F.R.; Campos, J.B.L.M.

    2008-01-01

    An experimental study on free-bubbling gas-liquid (air-water) vertical slug flow was developed using a non-intrusive image analysis technique. The flow pattern in the near-wake of the bubbles and in the main liquid between bubbles was turbulent. A single correlation for the bubble-to-bubble interaction is proposed, relating the trailing bubble velocity to the length of the liquid slug ahead of the bubble. The proposed correlation is shown to be independent of column diameter, column vertical coordinate, superficial liquid and gas velocities and the velocity and length of the leading bubble. Frequency distribution curves, averages, modes and standard deviations are reported, for distributions of bubble velocity, bubble length and liquid slug length, for each experimental condition studied. Good agreement was found between theoretical predictions and experimental results regarding the upward velocity of undisturbed bubbles, in a 0.032 m internal diameter column. A considerable discrepancy was found, though, for a 0.052 m internal diameter column. The acquired experimental data are crucial for the development and validation of a robust slug flow simulator

  12. Highly Selective Continuous Gas-Phase Methoxycarbonylation of Ethylene with Supported Ionic Liquid Phase (SILP) Catalysts

    DEFF Research Database (Denmark)

    Khokarale, Santosh Govind; Garcia Suárez, Eduardo José; Fehrmann, Rasmus

    2017-01-01

    Supported ionic liquid phase (SILP) technology was applied for the first time to the Pd-catalyzed continuous, gas-phase methoxycarbonylation of ethylene to selectively produce methyl propanoate (MP) in high yields. The influence of catalyst and reaction parameters such as, for example, ionic liquid...

  13. Glyoxal and methylglyoxal as urinary markers of diabetes. Determination using a dispersive liquid-liquid microextraction procedure combined with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Pastor-Belda, M; Fernández-García, A J; Campillo, N; Pérez-Cárceles, M D; Motas, M; Hernández-Córdoba, M; Viñas, P

    2017-08-04

    Glyoxal (GO) and methylglyoxal (MGO) are α-oxoaldehydes that can be used as urinary diabetes markers. In this study, their levels were measured using a sample preparation procedure based on salting-out assisted liquid-liquid extraction (SALLE) and dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography-mass spectrometry (GC-MS). The effect of the derivatization reaction with 2,3-diaminonaphthalene, the addition of acetonitrile and sodium chloride to urine, and the DLLME step using the acetonitrile extract as dispersant solvent and carbon tetrachloride as extractant solvent were carefully optimized. Quantification was performed by the internal standard method, using 5-bromo-2-chloroanisole. The intraday and interday precisions were lower than 6%. Limits of detection were 0.12 and 0.06ngmL -1 , and enrichment factors 140 and 130 for GO and MGO, respectively. The concentrations of these α-oxoaldehydes in urine were between 0.9 and 35.8ngg -1 levels (creatinine adjusted). A statistical comparison of the analyte contents of urine samples from non-diabetic and diabetic patients pointed to significant differences (P=0.046, 24 subjects investigated), particularly regarding MGO, which was higher in diabetic patients. The novelty of this study compared with previous procedures lies in the treatment of the urine sample by SALLE based on the addition of acetonitrile and sodium chloride to the urine. The DLLME procedure is performed with a sedimented drop of the extractant solvent, without a surfactant reagent, and using acetonitrile as dispersant solvent. Separation of the analytes was performed using GC-MS detection, being the analytes unequivocal identified. The proposed procedure is the first microextraction method applied to the analysis of urine samples from diabetic and non-diabetic patients that allows a clear differentiation between both groups using a simple analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Prediction of gas and liquid turbulent mixing rates between rod bundle subchannels in a two-phase slug-churn flow

    International Nuclear Information System (INIS)

    Kawahara, Akimaro; Sadatomi, Michio; Tomino, Takayoshi

    2000-01-01

    This paper presents a slug-churn flow model for predicting turbulent mixing rates of both gas and liquid phases between adjacent subchannels in a BWR fuel rod bundle. In the model, the mixing rate of the liquid phase is calculated as the sum of the three components, i.e., turbulent diffusion, convective transfer and pressure difference fluctuations between the subchannels. The components of turbulent diffusion and convective transfer are calculated from Sadatomi et al.'s (1996) method, applicable to single-phase turbulent mixing, by considering the effect of the increment of liquid velocity due to the presence of gas phase. The component of the pressure difference fluctuations is evaluated from a newly developed correlation. The mixing rate of the gas phase, on the other side, is calculated from a simple relation of mixing rate between gas and liquid phases. The validity of the proposed model has been confirmed with the turbulent mixing rates data of Rudzinski et al. as well as the present authors. (author)

  15. Gas-liquid transition in the model of particles interacting at high energy

    International Nuclear Information System (INIS)

    Bondarenko, S.; Komoshvili, K.

    2013-01-01

    An application of the ideas of the inertial confinement fusion process in the case of particles interacting at high energy is investigated. A possibility of the gas-liquid transition in the gas is considered using different approaches. In particular, a shock wave description of interactions between particles is studied and a self-similar solution of Euler's equation is discussed. Additionally, the Boltzmann equation is solved for a self-consistent field (Vlasov's equation) in the linear approximation for the case of a gas under external pressure and the corresponding change of the Knudsen number of the system is calculated. (orig.)

  16. Response of small pitot tubes in gas-liquid flows

    International Nuclear Information System (INIS)

    Davis, M.R.

    1980-01-01

    The pressure rise experienced by a pitot tube immersed in a bubbly gas-liquid mixture flow exceeds that predicted by homogeneous flow analysis under conditions where the pitot is smaller than the mean bubble size. A systematic dependence of the deviation from homogeneous flow analysis exists, depending upon the mixture void fraction. A maximum effect is observed at a void fraction of 0.60, where the pressure rise was found to be 1.73 times the predicted stagnation pressure rise or 0.87 of the mixture momentum flux density. The magnitude of these effects is comparable with similar effects reported elsewhere for gas/solid mixture flow due to relative motion between phases in the vicinity of the sensing probe tip. (orig.)

  17. THE INFLUENCE OF GAS-DENSITY AND LIQUID PROPERTIES ON BUBBLE BREAKUP

    NARCIS (Netherlands)

    WILKINSON, PM; VANSCHAYK, A; SPRONKEN, JPM; VANDIERENDONCK, LL

    On the basis of a literature review of bubble breakup experiments, it is demonstrated that both liquid viscosity and surface tension have an influence on bubble stability and, thus, bubble breakup, for small as well as large bubbles. Possible influences of the gas properties on bubble breakup have

  18. Influence of dissolved gas and temperature on the light yield of new liquid scintillators

    CERN Document Server

    Buontempo, S; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    Sixteen new liquid scintillators, emitting green light, were studied. They are based on four solvents combined with four dopants. The influence of different gas atmospheres was studied. In particular it was shown that by keeping these liquid scintillators in vacuum or in a neutral gas, the light yield increases up to 32~\\% at 20 $^{\\circ}$C and for the best solvent-dopant combinations. The dependance of the light yield on temperature was also studied for these scintillators. In the 20--60 $^{\\circ}$C interval, some exhibit a light yield variation of $\\sim$ 3 \\% which is smaller than that of the NE 102A plastic scintillator.

  19. System for measurement and automatic regulation of gas flow within an oil aging test device

    Directory of Open Access Journals (Sweden)

    Žigić Aleksandar

    2014-01-01

    Full Text Available This paper describes a system within an oil aging test device that serves for measurement and automatic regulation of gas flow. Following an already realized system that continuously monitors, logs, and regulates transformer oil temperature during the aging process and maintains temperature consistency within strict limits, a model of a flow meter and regulator of air or oxygen through transformer oil samples is developed. A special feature of the implemented system is the measurement of very small gas flows. A short technical description of the realized system is given with a functional block diagram. The basic technical characteristics of the system are specified, and the operating principles and application of the system are described. The paper also gives performance test results in a real exploitation environment.

  20. Laser ablated copper plasmas in liquid and gas ambient

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Bhupesh; Thareja, Raj K. [Department of Physics, Indian Institute of Technology Kanpur, Kanpur 208 016 (India)

    2013-05-15

    The dynamics of copper ablated plasma plumes generated using laser ablation of copper targets in both liquid (de-ionized water) and gas (air) ambients is reported. Using time and space resolved visible emission spectroscopy (450-650 nm), the plasma plumes parameters are investigated. The electron density (n{sub e}) determined using Stark broadening of the Cu I (3d{sup 10}4d{sup 1} {sup 2}D{sub 3/2}-3d{sup 10}4p{sup 1} {sup 2}P{sub 3/2} at 521.8 nm) line is estimated and compared for both plasma plumes. The electron temperature (T{sub e}) was estimated using the relative line emission intensities of the neutral copper transitions. Field emission scanning electron microscopy and energy dispersive x-ray spectral analysis of the ablated copper surface indicated abundance of spherical nanoparticles in liquid while those in air are amalgamates of irregular shapes. The nanoparticles suspended in the confining liquid form aggregates and exhibit a surface plasmon resonance at ∼590 nm.

  1. Price dynamics in the market for Liquid Petroleum Gas transport

    International Nuclear Information System (INIS)

    Adland, Roar; Jia Haiying; Lu Jing

    2008-01-01

    The purpose of this paper is to investigate the dynamics of the spot freight rate in the Liquid Petroleum Gas (LPG) shipping market. The spot freight rate process is nonparametrically specified so that the model allows for maximal flexibility in fitting the data. The model is estimated using data for the Very Large Gas Carrier (VLGC) sector and the estimation results are compared to those of crude oil tankers available in the literature. The empirical results suggest that the LPG spot freight rate can be appropriately described by a simple linear stochastic model and does not exhibit the non-linearity found in other bulk shipping sectors

  2. Desorption of trihalomethanes in gas liquid contactors

    International Nuclear Information System (INIS)

    Ramirez Quesada, Kenneth

    2000-01-01

    Updated studies show that gastric cancer is related with the existence of trihalomethanes (THMs) in the drinking water. The trihalomethanes are sub products from the degradation of humic acids and your reaction with chlorine and bromine used like decontaminates. The desorption process is used to eliminate the THMs with air in contact with the water. The experimental design was used in three contactors. The contactors selected were: the bubbling's column, the packed column and the shaken tank without screen. There were selected three variable: initial concentration of THMs, the residence time and the turbulence degree (measured with the Reynolds number). The concentrations were made with a gas chromatograph. The objective of this project is to do a comparison with the gas liquid contactors more used in the industrial level to determinate which ones are the best in the desorption process. The conclusion of the experimental design is that the tank is the equipment with the best capacity to eliminate THMs. Too it includes other techniques to eliminate THMs of the water and your treatment [es

  3. Short-term outlook for natural gas and natural gas liquids to 2006 : an energy market assessment

    International Nuclear Information System (INIS)

    2005-10-01

    In recent years, natural gas markets in North America have seen a close balance between supply and demand, resulting in high and volatile natural gas prices. The National Energy Board monitors the supply of all energy commodities in Canada along with the demand for Canadian energy commodities in domestic and export markets. This is the NEB's first energy market assessment report that presents a combined short-term analysis and outlook of natural gas and natural gas liquids (NGLs), such as ethane, propane and butane. It provides comprehensive information on the complexity of natural gas and NGL industries and highlights recent developments and topical issues. As a major producer of natural gas, western Canada has a correspondingly large natural gas processing capability that was developed specifically to extract NGLs. A world-scale petrochemical industry was developed in Alberta to convert NGLs into even higher valued products such as ethylene. Since NGLs in Canada are sourced mostly from natural gas, changes to the supply and demand for natural gas would impact NGL supply. This report addressed the issue of commodity prices with reference to crude oil, natural gas and NGL prices. Natural gas supply in terms of North American production and natural gas from coal (NGC) was also reviewed along with natural gas demand for residential and commercial heating, industrial use, power generation, and enhanced recovery for oil sand operations. There are about 692 gas plants in Canada that process raw natural gas into marketable gas and NGLs. Most are small field plants that process raw natural gas production to remove impurities such as sulphur, water and other contaminants. This report also discussed this infrastructure, with reference to field plants, straddle plants, pipelines, distribution and storage, including underground NGL storage. 3 tabs., 27 figs., 5 appendices

  4. About the statistical description of gas-liquid flows

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, D.; Guido-Lavalle, G.; Carrica, P. [Centro Atomico Bariloche and Instituto Balseiro (Argentina)] [and others

    1995-09-01

    Elements of the probabilistic geometry are used to derive the bubble coalescence term of the statistical description of gas liquid flows. It is shown that the Boltzmann`s hypothesis, that leads to the kinetic theory of dilute gases, is not appropriate for this kind of flows. The resulting integro-differential transport equation is numerically integrated to study the flow development in slender bubble columns. The solution remarkably predicts the transition from bubbly to slug flow pattern. Moreover, a bubbly bimodal size distribution is predicted, which has already been observed experimentally.

  5. Two-phase gas bubble-liquid boundary layer flow along vertical and inclined surfaces

    International Nuclear Information System (INIS)

    Cheung, F.B.; Epstein, M.

    1985-01-01

    The behavior of a two-phase gas bubble liquid boundary layer along vertical and inclined porous surfaces with uniform gas injection is investigated experimentally and analytically. Using argon gas and water as the working fluids, a photographical study of the two-phase boundary layer flow has been performed for various angles of inclination ranging from 45 0 to 135 0 and gas injection rates ranging from 0.01 to 0.1 m/s. An integral method has been employed to solve the system of equations governing the two-phase motion. The effects of the gas injection rate and the angle of inclination on the growth of the boundary layer have been determined

  6. Trigeneration scheme for a natural gas liquids extraction plant in the Middle East

    International Nuclear Information System (INIS)

    Eveloy, Valérie; Rodgers, Peter; Popli, Sahil

    2014-01-01

    Highlights: • Trigeneration scheme tailored to natural gas liquids extraction plant. • High ambient temperature and RH conditions in the Persian Gulf. • Absorption refrigeration powered by gas turbine (GT) exhaust gas waste heat. • GT compressor inlet air- and process gas cooling, process gas heating. • Significant OPEX and primary energy savings, favorable payback period and net present value. - Abstract: Natural gas processing plants in the Persian Gulf face extreme climatic conditions that constrain their gas turbine (GT) power generation and cooling capacities. However, due to a past history of low hydrocarbon prices, such plants have not fully exploited their waste heat recovery potential to date. The techno-economic performance of a combined cooling, heating and power (CCHP) scheme designed to enhance the energy efficiency of a major natural gas liquids extraction plant in the Persian Gulf is assessed. The trigeneration scheme utilizes double-effect water–lithium bromide absorption refrigeration powered by steam generated from GT exhaust gas waste heat to provide both GT compressor inlet air- and process gas cooling. Part of the generated steam is also used for process gas heating. Thermodynamic modeling reveals that recovery of 82 MW of GT waste heat would provide additional cooling and heating capacities of 75 MW and 24 MW to the plant, respectively, thereby permitting elimination of a 28 MW GT, and existing cooling and heating equipment. GT compressor inlet air cooling alone yields approximately 151 GW h of additional electric power annually, highlighting the effectiveness of absorption refrigeration in meeting compressor inlet air cooling loads throughout the year in the Gulf climate. The overall net annual operating expenditure savings contributed by the CCHP system would average approximately 14.6 million US$ over its lifespan, which corresponds to average yearly savings of 190 MMSCM of natural gas. The CCHP scheme economic payback period is

  7. Liquid kit for preparation of 188rhenium-etidronate

    International Nuclear Information System (INIS)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto

    2005-01-01

    The aim of this study was the preparation of a liquid kit for radiolabeling of 188 Re-HEDP (hydroxyethylidene diphosphonate). 188 Re was obtained from alumina based 188 W/ 188 Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of 188 Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  8. Automatic development of normal zone in composite MgB2/CuNi wires with different diameters

    Science.gov (United States)

    Jokinen, A.; Kajikawa, K.; Takahashi, M.; Okada, M.

    2010-06-01

    One of the promising applications with superconducting technology for hydrogen utilization is a sensor with a magnesium-diboride (MgB2) superconductor to detect the position of boundary between the liquid hydrogen and the evaporated gas stored in a Dewar vessel. In our previous experiment for the level sensor, the normal zone has been automatically developed and therefore any energy input with the heater has not been required for normal operation. Although the physical mechanism for such a property of the MgB2 wire has not been clarified yet, the deliberate application might lead to the realization of a simpler superconducting level sensor without heater system. In the present study, the automatic development of normal zone with increasing a transport current is evaluated for samples consisting of three kinds of MgB2 wires with CuNi sheath and different diameters immersed in liquid helium. The influences of the repeats of current excitation and heat cycle on the normal zone development are discussed experimentally. The aim of this paper is to confirm the suitability of MgB2 wire in a heater free level sensor application. This could lead to even more optimized design of the liquid hydrogen level sensor and the removal of extra heater input.

  9. An Assessment of Energy and Environmental Issues Related to the Use of Gas-to-Liquid Fuels in Transportation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, D.L.

    1999-11-01

    Recent technological advances in processes for converting natural gas into liquid fuels, combined with a growing need for cleaner, low-sulfur distillate fuel to mitigate the environmental impacts of diesel engines have raised the possibility of a substantial global gas-to-liquids (G-T-L) industry. This report examines the implications of G-T-L supply for U.S. energy security and the environment. It appears that a G-T-L industry would increase competitiveness in world liquid fuels markets, even if OPEC states are major producers of G-T-L's. Cleaner G-T-L distillates would help reduce air pollution from diesel engines. Implications for greenhouse gas (GHG) emissions could be positive or negative, depending on the sources of natural gas, their alternative uses, and the degree of sequestration that can be achieved for CO2 emissions produced during the conversion process.

  10. An assessment of energy and environmental issues related to the use of gas-to-liquid fuels in transportation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, D.L.

    1999-11-01

    Recent technological advances in processes for converting natural gas into liquid fuels, combined with a growing need for cleaner, low-sulfur distillate fuel to mitigate the environmental impacts of diesel engines have raised the possibility of a substantial global gas-to-liquids (G-T-L) industry. This report examines the implications of G-T-L supply for U.S. energy security and the environment. It appears that a G-T-L industry would increase competitiveness in world liquid fuels markets, even if OPEC states are major producers of G-T-L's. Cleaner G-T-L distillates would help reduce air pollution from diesel engines. Implications for greenhouse gas (GHG) emissions could be positive or negative, depending on the sources of natural gas, their alternative uses, and the degree of sequestration that can be achieved for CO{sub 2} emissions produced during the conversion process.

  11. Activity coefficients at infinite dilution for solutes in the trioctylmethylammonium bis(trifluoromethylsulfonyl)imide ionic liquid using gas-liquid chromatography

    International Nuclear Information System (INIS)

    Gwala, Nobuhle V.; Deenadayalu, Nirmala; Tumba, Kaniki; Ramjugernath, Deresh

    2010-01-01

    The activity coefficient at infinite dilution (γ 13 ∞ ) for 30 solutes: alkanes, alkenes, cycloalkanes, alkynes, ketones, alcohols, and aromatic compounds was determined from gas-liquid chromatography (glc) measurements at three temperatures (303.15, 313.15, and 323.15) K. The ionic liquid: trioctylmethylammonium bis(trifluoromethylsulfonyl)imide, was used as the stationary phase. For each temperature, γ 13 ∞ values were determined using two columns with different mass percent packing of the ionic liquid. The selectivity (S 12 ∞ ) value was calculated from the γ 13 ∞ to determine the suitability of the solvent as a potential entrainer for extractive distillation in the separation of an hexane/benzene mixture, indicative of a typical industrial separation problem for benchmarking purposes.

  12. Diagnostic monitoring of the condition of the amplification-transformer channel of automatic gas protection apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Karpov, Ye F; Basovskiy, B I; Popov, V V

    1978-01-01

    A method is suggested for verifying the performance capacity of an amplifier-transformer channel of apparatus for automatic gas protection under operating conditions. Processes are examined which occur in the bridge measurement plan of the sensor during shunting of one of the thermal-transformer elements by a resistor. An expression is obtained for determining the coefficient of transfer of the amplification-transformer channel on the outlet signals of the apparatus in a working regime and after shunting of one of the thermal-transformer elements.

  13. Numerical simulation of interface movement in gas-liquid two-phase flows with Level Set method

    International Nuclear Information System (INIS)

    Li Huixiong; Chinese Academy of Sciences, Beijing; Deng Sheng; Chen Tingkuan; Zhao Jianfu; Wang Fei

    2005-01-01

    Numerical simulation of gas-liquid two-phase flow and heat transfer has been an attractive work for a quite long time, but still remains as a knotty difficulty due to the inherent complexities of the gas-liquid two-phase flow resulted from the existence of moving interfaces with topology changes. This paper reports the effort and the latest advances that have been made by the authors, with special emphasis on the methods for computing solutions to the advection equation of the Level set function, which is utilized to capture the moving interfaces in gas-liquid two-phase flows. Three different schemes, i.e. the simple finite difference scheme, the Superbee-TVD scheme and the 5-order WENO scheme in combination with the Runge-Kutta method are respectively applied to solve the advection equation of the Level Set. A numerical procedure based on the well-verified SIMPLER method is employed to numerically calculate the momentum equations of the two-phase flow. The above-mentioned three schemes are employed to simulate the movement of four typical interfaces under 5 typical flowing conditions. Analysis of the numerical results shows that the 5-order WENO scheme and the Superbee-TVD scheme are much better than the simple finite difference scheme, and the 5-order WENO scheme is the best to compute solutions to the advection equation of the Level Set. The 5-order WENO scheme will be employed as the main scheme to get solutions to the advection equations of the Level Set when gas-liquid two-phase flows are numerically studied in the future. (authors)

  14. Fate of ethanol during cooking of liquid foods prepared with alcoholic beverages

    DEFF Research Database (Denmark)

    Snitkjær, Pia; Ryapushkina, Julia; Skovenborg, Erik

    2017-01-01

    To obtain an understanding of the ethanol loss during cooking of liquid foods containing alcoholic beverages, ethanol concentration was measured as a function of time and remaining volume in meat stocks prepared with wine and beer. A mathematical model describing the decline in volatile compounds...... like pot dimensions and temperature. When using a lid to cover the pot during cooking, the model was still valid but the ethanol concentrations decreased more steeply, corresponding to a higher exponent. The results provide a theoretical and empirical guideline for predicting the ethanol concentration...... in cooked liquid foods...

  15. KAJI EKSPERIMENTAL PENGGUNAAN LIQUID GAS FOR VEHICLE (LGV DENGAN PERTAMAX TERHADAP PERFORMA DAN EMISI GAS BUANG MOTOR BENSIN 2000 cc

    Directory of Open Access Journals (Sweden)

    Muhamad As’adi

    2017-03-01

    Full Text Available APBN 2015 mengisyaratkan bahwa Pemerintah akan mengurangi subsidi Bahan Bakar Minyak dari 48 juta kilo liter menjadi 46 juta kilo liter, implikasi dari hal ini jelas akan berdampak pada kebijakan penggunaan BBM dalam rangka untuk memenuhi kebutuhan sektor transportasi dan industri. Salah satu bahan bakar yang cadangannya masih cukup banyak dan pemanfaatannya masih terbatas pada kebutuhan rumah tangga serta usaha sector kuliner adalah Liquid Petrolium Gas (LPG. LPG mempunyai produk turunan dengan merk dagang Elpiji dan Liquid Gas for Vehicle (LGV atau sering disebut dengan Vigas. LGV mempunyai RON 98 setara dengan bahan bakar Pertamax dan mudah disimpan dalam tangki portabel karena tekanan nya relative rendah yaitu 8-15 bar, sedangakan tekanan bahan bakar Compressed Natural Gas (CNG yang sering disebut dengan Bahan Bakar Gas (BBG sekitar 200 bar. Perkembangan penggunaan LGV di masyarakat cenderung lambat hal ini disebabkan oleh keterbatasan infrastruktur yang ada dan pemahaman masyarakat tentang penggunaan LGV untuk sektor transportasi masih kurang. Tujuan dan target penelitian ini adalah didapatkannya konstanta performa dari motor bensin yang berbahan bakar LGV dan Pertamax, sehingga dapat memberikan pengetahuan kepada masyarakat bahwa LGV bisa digunakan sebagai bahan bakar pada sector transportasi dan lebih ekonomis. Metode yang digunakan dalam penelitian ini adalah metode eksprimen dengan mesin uji motor bensin 2000 cc yang berbahan bakar LGV dan Pertamax. Pengujian dilakukan dengan uji static diatas Dyno Test. Luaran data yang dihasilkan berupa performa mesin yang meliputi torsi, daya, konsumsi bahan bakar, selain uji static juga dilakukan uji emisi gas buang. Hasil pengujian menunjukkan bahwa enggunaan Liquid Gas For Vehicle (LGV dengan merk dagang Vigas mampu menaikkan Daya mesin maksimum sebesar 20,86% dan daya rata-rata sebesar 14,1%, torsi maksimum yang dihasilkan oleh Motor berbahan bakar Vigas lebih kecil dari motor yang berbahan bakar

  16. Do medium heavy fragments give evidence for a liquid-gas phase transition

    International Nuclear Information System (INIS)

    Trockel, R.; Hildenbrand, K.D.; Lynen, U.; Mueller, W.F.J.; Rabe, H.J.; Sann, H.; Stelzer, H.; Wada, R.; Brummund, N.; Glasow, R.; Kampert, K.H.; Santo, R.; Pelte, D.; Pochodzalla, J.; Eckert, E.

    1985-09-01

    Light and medium heavy fragments have been measured in light ion induced reactions at intermediate energies. The energy spectra have been parametrized with moving source fits. The resulting temperatures and yields do not confirm the expectations of a liquid-gas phase transition. (orig.)

  17. Hydrodynamics in a cocurrent gas-liquid trickle bed at elevated pressures

    NARCIS (Netherlands)

    Wammes, W.J.A.; Middelkamp, J.; Huisman, W.J.; Huisman, W.J.; de Baas, C.M.; de Baas, C.M.; Westerterp, K.R.

    1991-01-01

    Data on design and operation of trickle beds at elevated pressures are scarce. In this study the influence of the gas density on the liquid holdup, the pressure drop, and the transition between trickle and pulse flow has been investigated in a tricklebed reactor operating up to 7.5 MPa and with

  18. Comparison of electrical and optical characteristics in gas-phase and gas-liquid phase discharges

    Energy Technology Data Exchange (ETDEWEB)

    Qazi, H. I. A.; Li, He-Ping, E-mail: liheping@tsinghua.edu.cn; Zhang, Xiao-Fei; Bao, Cheng-Yu [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Nie, Qiu-Yue [School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, Heilongjiang Province 150001 (China)

    2015-12-15

    This paper presents an AC-excited argon discharge generated using a gas-liquid (two-phase) hybrid plasma reactor, which mainly consists of a powered needle electrode enclosed in a conical quartz tube and grounded deionized water electrode. The discharges in the gas-phase, as well as in the two-phase, exhibit two discharge modes, i.e., the low current glow-like diffuse mode and the high current streamer-like constrict mode, with a mode transition, which exhibits a negative resistance of the discharges. The optical emission spectral analysis shows that the stronger diffusion of the water vapor into the discharge region in the two-phase discharges boosts up the generation of OH (A–X) radicals, and consequently, leads to a higher rotational temperature in the water-phase plasma plume than that of the gas-phase discharges. Both the increase of the power input and the decrease of the argon flow rate result in the increase of the rotational temperature in the plasma plume of the water-phase discharge. The stable two-phase discharges with a long plasma plume in the water-phase under a low power input and gas flow rate may show a promising prospect for the degradation of organic pollutants, e.g., printing and dyeing wastewater, in the field of environmental protection.

  19. Informing hazardous zones for on-board maritime hydrogen liquid and gas systems

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, Myra L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Pratt, Joseph William [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Bran Anleu, Gabriela A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Proctor, Camron [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2018-01-01

    The significantly higher buoyancy of hydrogen compared to natural gas means that hazardous zones defined in the IGF code may be inaccurate if applied to hydrogen. This could place undue burden on ship design or could lead to situations that are unknowingly unsafe. We present dispersion analyses to examine three vessel case studies: (1) abnormal external vents of full blowdown of a liquid hydrogen tank due to a failed relief device in still air and with crosswind; (2) vents due to naturally-occurring boil-off of liquid within the tank; and (3) a leak from the pipes leading into the fuel cell room. The size of the hydrogen plumes resulting from a blowdown of the tank depend greatly on the wind conditions. It was also found that for normal operations releasing a small amount of "boil- off" gas to regulate the pressure in the tank does not create flammable concentrations.

  20. Gas separation techniques with liquid Ar for production of 11C ions

    International Nuclear Information System (INIS)

    Hojo, Satoru; Honma, Toshihiro; Kanazawa, Mitsutaka; Muramatsu, Masayuki; Sakamoto, Yukio; Sugiura, Akinori; Suzuki, Naokata; Noda, Koji

    2009-01-01

    Heavy-ion cancer therapy with 12 C-beam has been carried out at HIMAC (Heavy Ion Medical Accelerator in Chiba) in NIRS (National Institute of Radiological Sciences) since 1994. One of the feasibility study in HIMAC is to use a positron emitter beam such as 11 C-beam for the cancer therapy. A nuclear reaction, 14 N (p,α) 11 C will be applied in the present study; it can be expected to obtain a considerably large number of 11 C-particles by utilizing the commonly used short-lives RI production techniques for PET (Positron Emission Tomography). The amount of 11 C gas is limited in this technique. The 11 CO 2 gas was produced from N 2 gas that is irradiated high-energy proton beam. Therefore, CO 2 gas separation from N 2 gas is very important. The gas-separation techniques with cryogenic system utilizing a liquid Ar were tested by dummy gas (N 2 + 12 CO 2 ). Details of the gas-separation techniques and measurement of CO 2 partial pressure are discussed. (author)

  1. Gas--liquid chromatographic determination of total inorganic iodine in milk

    International Nuclear Information System (INIS)

    Bakker, H.J.

    1977-01-01

    Total inorganic iodine in milk is determined by conversion to iodobutanone, which is quantitated by gas-liquid chromatography and electron capture detection. As little as 10 μg/L can be determined. The thyroid-active iodine content of milk can be determined rapidly with a relative standard deviation of 1.9%. Average recoveries for added iodide and iodine were 95.5 and 94.6%, respectively

  2. Technology of off-gas treatment for liquid-fed ceramic melters

    Energy Technology Data Exchange (ETDEWEB)

    Scott, P.A.; Goles, R.W.; Peters, R.D.

    1985-05-01

    The technology for treating off gas from liquid-fed ceramic melters (LFCMs) has been under development at the Pacific Northwest Laboratory since 1977. This report presents the off-gas technology as developed at PNL and by others to establish a benchmark of development and to identify technical issues. Tests conducted on simulated (nonradioactive) wastes have provided data that allow estimation of melter off-gas composition for a given waste. Mechanisms controlling volatilization of radionuclides and noxious gases are postulated, and correlations between melter operation and emissions are presented. This report is directed to those familiar with LFCM operation. Off-gas treatment systems always require primary quench scrubbers, aerosol scrubbers, and final particulate filters. Depending on the composition of the off gas, equipment for removal of ruthenium, iodine, tritium, and noxious gases may also be needed. Nitrogen oxides are the most common noxious gases requiring treatment, and can be controlled by aqueous absorption or catalytic conversion with ammonia. High efficiency particulate air (HEPA) filters should be used for final filtration. The design criteria needed for an off-gas system can be derived from emission regulations and composition of the melter feed. Conservative values for melter off-gas composition can be specified by statistical treatment of reported off-gas data. Statistical evaluation can also be used to predict the frequency and magnitude of normal surge events that occur in the melter. 44 refs., 28 figs., 17 tabs.

  3. Separation of Gas Mixtures by New Type of Membranes – Dynamic Liquid Membranes.

    Czech Academy of Sciences Publication Activity Database

    Setničková, Kateřina; Šíma, Vladimír; Petričkovič, Roman; Řezníčková Čermáková, Jiřina; Uchytil, Petr

    2016-01-01

    Roč. 160, FEB 29 (2016), s. 132-135 ISSN 1383-5866 Institutional support: RVO:67985858 Keywords : gas separation * liquid membrane * methane Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.359, year: 2016

  4. Crosslinked Polymer Ionic Liquid/Ionic Liquid Blends Prepared by Photopolymerization as Solid-State Electrolytes in Supercapacitors

    Science.gov (United States)

    Wang, Po-Hsin; Wang, Tzong-Liu; Lin, Wen-Churng; Lin, Hung-Yin; Lee, Mei-Hwa; Yang, Chien-Hsin

    2018-01-01

    A photopolymerization method is used to prepare a mixture of polymer ionic liquid (PIL) and ionic liquid (IL). This mixture is used as a solid-state electrolyte in carbon nanoparticle (CNP)-based symmetric supercapacitors. The solid electrolyte is a binary mixture of a PIL and its corresponding IL. The PIL matrix is a cross-linked polyelectrolyte with an imidazole salt cation coupled with two anions of Br− in PIL-M-(Br) and TFSI− in PIL-M-(TFSI), respectively. The corresponding ionic liquids have imidazolium salt cation coupled with two anions of Br− and TFSI−, respectively. This study investigates the electrochemical characteristics of PILs and their corresponding IL mixtures used as a solid electrolyte in supercapacitors. Results show that a specific capacitance, maximum power density and energy density of 87 and 58 F·g−1, 40 and 48 kW·kg−1, and 107 and 59.9 Wh·kg−1 were achieved in supercapacitors based on (PIL-M-(Br)) and (PIL-M-(TFSI)) solid electrolytes, respectively. PMID:29642456

  5. Crosslinked Polymer Ionic Liquid/Ionic Liquid Blends Prepared by Photopolymerization as Solid-State Electrolytes in Supercapacitors

    Directory of Open Access Journals (Sweden)

    Po-Hsin Wang

    2018-04-01

    Full Text Available A photopolymerization method is used to prepare a mixture of polymer ionic liquid (PIL and ionic liquid (IL. This mixture is used as a solid-state electrolyte in carbon nanoparticle (CNP-based symmetric supercapacitors. The solid electrolyte is a binary mixture of a PIL and its corresponding IL. The PIL matrix is a cross-linked polyelectrolyte with an imidazole salt cation coupled with two anions of Br− in PIL-M-(Br and TFSI− in PIL-M-(TFSI, respectively. The corresponding ionic liquids have imidazolium salt cation coupled with two anions of Br− and TFSI−, respectively. This study investigates the electrochemical characteristics of PILs and their corresponding IL mixtures used as a solid electrolyte in supercapacitors. Results show that a specific capacitance, maximum power density and energy density of 87 and 58 F·g−1, 40 and 48 kW·kg−1, and 107 and 59.9 Wh·kg−1 were achieved in supercapacitors based on (PIL-M-(Br and (PIL-M-(TFSI solid electrolytes, respectively.

  6. Direct numerical simulation of stratified gas-liquid flow

    International Nuclear Information System (INIS)

    Lombardi, P.; De Angelis, V.; Banerjee, S.

    1996-01-01

    Interactions through an interface between two turbulent flows play an important role in many environmental and industrial problems, e.g. in determining the coupling fluxes of heat mass and momentum, between the ocean and atmosphere, and in the design of gas-liquid contractors for the chemical industry, as well as in determining interactions between phases in nuclear transients that are accompanied by system voiding e.g. LOCAs. Here, the Direct Numerical Simulation (DNS) of the interaction of two turbulent fluids through a flat interface has been simulated. The flow and the temperature fields are computed using a pseudospectral method. This study shows that shear stress at the interface correlates well with the heat flux. Extensive analysis of the near interface turbulence structure has been performed using quadrant analysis. From this it is clear that gas-side sweeps dominate over the high shear stress regions. This suggests that simple parameterizations based on sweep frequency may be adequate for predictions of scalar transport rates

  7. Zpif's law in the liquid gas phase transition of nuclei

    International Nuclear Information System (INIS)

    Ma, Y.G.

    1999-01-01

    Zpif's law in the field of linguistics is tested in the nuclear disassembly within the framework of isospin dependent lattice gas model. It is found that the average cluster charge (or mass) of rank n in the charge (or mass) list shows exactly inversely to its rank, i.e., there exists Zpif's law, at the phase transition temperature. This novel criterion shall be helpful to search the nuclear liquid gas phase transition experimentally and theoretically. In addition, the finite size scaling of the effective phase transition temperature at which the Zpif's law appears is studied for several systems with different mass and the critical exponents of ν and β are tentatively extracted. (orig.)

  8. Genital automatisms: Reappraisal of a remarkable but ignored symptom of focal seizures.

    Science.gov (United States)

    Dede, Hava Özlem; Bebek, Nerses; Gürses, Candan; Baysal-Kıraç, Leyla; Baykan, Betül; Gökyiğit, Ayşen

    2018-03-01

    Genital automatisms (GAs) are uncommon clinical phenomena of focal seizures. They are defined as repeated fondling, grabbing, or scratching of the genitals. The aim of this study was to determine the lateralizing and localizing value and associated clinical characteristics of GAs. Three hundred thirteen consecutive patients with drug-resistant seizures who were referred to our tertiary center for presurgical evaluation between 2009 and 2016 were investigated. The incidence of specific kinds of behavior, clinical semiology, associated symptoms/signs with corresponding ictal electroencephalography (EEG) findings, and their potential role in seizure localization and lateralization were evaluated. Fifteen (4.8%) of 313 patients had GAs. Genital automatisms were identified in 19 (16.4%) of a total 116 seizures. Genital automatisms were observed to occur more often in men than in women (M/F: 10/5). Nine of fifteen patients (60%) had temporal lobe epilepsy (right/left: 4/5) and three (20%) had frontal lobe epilepsy (right/left: 1/2), whereas the remaining two patients could not be classified. One patient was diagnosed as having Rasmussen encephalitis. Genital automatisms were ipsilateral to epileptic focus in 12 patients and contralateral in only one patient according to ictal-interictal EEG and neuroimaging findings. Epileptic focus could not be lateralized in the last 2 patients. Genital automatisms were associated with unilateral hand automatisms such as postictal nose wiping or manual automatisms in 13 (86.7%) of 15 and contralateral dystonia was seen in 6 patients. All patients had amnesia of the performance of GAs. Genital automatisms are more frequent in seizures originating from the temporal lobe, and they can also be seen in frontal lobe seizures. Genital automatisms seem to have a high lateralizing value to the ipsilateral hemisphere and are mostly concordant with other unilateral hand automatisms. Men exhibit GAs more often than women. Copyright © 2017

  9. Extensible automated dispersive liquid–liquid microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Li, Songqing; Hu, Lu; Chen, Ketao; Gao, Haixiang, E-mail: hxgao@cau.edu.cn

    2015-05-04

    Highlights: • An extensible automated dispersive liquid–liquid microextraction was developed. • A fully automatic SPE workstation with a modified operation program was used. • Ionic liquid-based in situ DLLME was used as model method. • SPE columns packed with nonwoven polypropylene fiber was used for phase separation. • The approach was applied to the determination of benzoylurea insecticides in water. - Abstract: In this study, a convenient and extensible automated ionic liquid-based in situ dispersive liquid–liquid microextraction (automated IL-based in situ DLLME) was developed. 1-Octyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]imide ([C{sub 8}MIM]NTf{sub 2}) is formed through the reaction between [C{sub 8}MIM]Cl and lithium bis[(trifluoromethane)sulfonyl]imide (LiNTf{sub 2}) to extract the analytes. Using a fully automatic SPE workstation, special SPE columns packed with nonwoven polypropylene (NWPP) fiber, and a modified operation program, the procedures of the IL-based in situ DLLME, including the collection of a water sample, injection of an ion exchange solvent, phase separation of the emulsified solution, elution of the retained extraction phase, and collection of the eluent into vials, can be performed automatically. The developed approach, coupled with high-performance liquid chromatography–diode array detection (HPLC–DAD), was successfully applied to the detection and concentration determination of benzoylurea (BU) insecticides in water samples. Parameters affecting the extraction performance were investigated and optimized. Under the optimized conditions, the proposed method achieved extraction recoveries of 80% to 89% for water samples. The limits of detection (LODs) of the method were in the range of 0.16–0.45 ng mL{sup −1}. The intra-column and inter-column relative standard deviations (RSDs) were <8.6%. Good linearity (r > 0.9986) was obtained over the calibration range from 2 to 500 ng mL{sup −1}. The proposed

  10. Extensible automated dispersive liquid–liquid microextraction

    International Nuclear Information System (INIS)

    Li, Songqing; Hu, Lu; Chen, Ketao; Gao, Haixiang

    2015-01-01

    Highlights: • An extensible automated dispersive liquid–liquid microextraction was developed. • A fully automatic SPE workstation with a modified operation program was used. • Ionic liquid-based in situ DLLME was used as model method. • SPE columns packed with nonwoven polypropylene fiber was used for phase separation. • The approach was applied to the determination of benzoylurea insecticides in water. - Abstract: In this study, a convenient and extensible automated ionic liquid-based in situ dispersive liquid–liquid microextraction (automated IL-based in situ DLLME) was developed. 1-Octyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]imide ([C 8 MIM]NTf 2 ) is formed through the reaction between [C 8 MIM]Cl and lithium bis[(trifluoromethane)sulfonyl]imide (LiNTf 2 ) to extract the analytes. Using a fully automatic SPE workstation, special SPE columns packed with nonwoven polypropylene (NWPP) fiber, and a modified operation program, the procedures of the IL-based in situ DLLME, including the collection of a water sample, injection of an ion exchange solvent, phase separation of the emulsified solution, elution of the retained extraction phase, and collection of the eluent into vials, can be performed automatically. The developed approach, coupled with high-performance liquid chromatography–diode array detection (HPLC–DAD), was successfully applied to the detection and concentration determination of benzoylurea (BU) insecticides in water samples. Parameters affecting the extraction performance were investigated and optimized. Under the optimized conditions, the proposed method achieved extraction recoveries of 80% to 89% for water samples. The limits of detection (LODs) of the method were in the range of 0.16–0.45 ng mL −1 . The intra-column and inter-column relative standard deviations (RSDs) were <8.6%. Good linearity (r > 0.9986) was obtained over the calibration range from 2 to 500 ng mL −1 . The proposed method opens a new avenue

  11. Film thickness in gas-liquid two-phase flow, (2)

    International Nuclear Information System (INIS)

    Sekoguchi, Kotohiko; Fukano, Toru; Kawakami, Yasushi; Shimizu, Hideo.

    1977-01-01

    The effect of four rectangular obstacles inserted into a circular tube has been studied in gas-liquid two-phase flow. The obstacles are set on the inner wall of the tube, and the ratio of the opening is 0.6. The water film flows partially through the obstacles. The minimum thickness of water film was measured in relation to flow speed. The serious effect of the obstacles was seen against the formation of water film, and drainage under the obstacles and backward flow play important roles. Since water film can flow partially through the obstacles, the film in case of the rectangular obstacles in thicker than that in case of an orifice when the gas flow speed was slower than 5 m/s. However, when the gas flow speed is over 5 m/s, the film thickness was thinner. The minimum film thickness of downstream of the obstacles was almost same as that in case of no obstacle. The minimum film thickness of up stream depends on the location of measurement due to the effect of drainage. (Kato, T.)

  12. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  13. Process for hydrogen isotope exchange and concentration between liquid water and hydrogen gas and catalyst assembly therefor

    International Nuclear Information System (INIS)

    Stevens, W.H.

    1975-01-01

    A bithermal, catalytic, hydrogen isotope exchange process between liquid water and hydrogen gas to effect concentration of the deuterium isotope of hydrogen is described. Liquid water and hydrogen gas are contacted with one another and with at least one catalytically active metal selected from Group VIII of the Periodic Table; the catalyst body has a water repellent, gas and water vapor permeable, organic polymer or resin coating, preferably a fluorinated olefin polymer or silicone resin coating, so that the isotope exchange takes place by two simultaneously occurring, and closely coupled in space, steps and concentration is effected by operating two interconnected sections containing catalyst at different temperatures. (U.S.)

  14. Controlled gas-liquid interfacial plasmas for synthesis of nano-bio-carbon conjugate materials

    Science.gov (United States)

    Kaneko, Toshiro; Hatakeyama, Rikizo

    2018-01-01

    Plasmas generated in contact with a liquid have been recognized to be a novel reactive field in nano-bio-carbon conjugate creation because several new chemical reactions have been yielded at the gas-liquid interface, which were induced by the physical dynamics of non-equilibrium plasmas. One is the ion irradiation to a liquid, which caused the spatially selective dissociation of the liquid and the generation of additive reducing and oxidizing agents, resulting in the spatially controlled synthesis of nanostructures. The other is the electron irradiation to a liquid, which directly enhanced the reduction action at the plasma-liquid interface, resulting in temporally controlled nanomaterial synthesis. Using this novel reaction field, gold nanoparticles with controlled interparticle distance were synthesized using carbon nanotubes as a template. Furthermore, nanoparticle-biomolecule conjugates and nanocarbon-biomolecule conjugates were successfully synthesized by an aqueous-solution contact plasma and an electrolyte plasma, respectively, which were rapid and low-damage processes suitable for nano-bio-carbon conjugate materials.

  15. The tenth CERI [Canadian Energy Research Institute] international oil and gas markets conference

    International Nuclear Information System (INIS)

    1991-01-01

    At a conference on oil and gas markets, papers were presented on oil market instability and its impact on economic development, international energy policy, oil supply and demand, natural gas liquids sales, world gas trade, gas markets in Europe and Asia, petroleum industry activities and their relation to government, oil refining and product market developments, and the North American natural gas market. Separate abstracts have been prepared for 25 papers from this conference

  16. Multiphase Transport in Porous Media: Gas-Liquid Separation Using Capillary Pressure Gradients International Space Station (ISS) Flight Experiment Development

    Science.gov (United States)

    Wheeler, Richard R., Jr.; Holtsnider, John T.; Dahl, Roger W.; Deeks, Dalton; Javanovic, Goran N.; Parker, James M.; Ehlert, Jim

    2013-01-01

    Advances in the understanding of multiphase flow characteristics under variable gravity conditions will ultimately lead to improved and as of yet unknown process designs for advanced space missions. Such novel processes will be of paramount importance to the success of future manned space exploration as we venture into our solar system and beyond. In addition, because of the ubiquitous nature and vital importance of biological and environmental processes involving airwater mixtures, knowledge gained about fundamental interactions and the governing properties of these mixtures will clearly benefit the quality of life here on our home planet. The techniques addressed in the current research involving multiphase transport in porous media and gas-liquid phase separation using capillary pressure gradients are also a logical candidate for a future International Space Station (ISS) flight experiment. Importantly, the novel and potentially very accurate Lattice-Boltzmann (LB) modeling of multiphase transport in porous media developed in this work offers significantly improved predictions of real world fluid physics phenomena, thereby promoting advanced process designs for both space and terrestrial applications.This 3-year research effort has culminated in the design and testing of a zero-g demonstration prototype. Both the hydrophilic (glass) and hydrophobic (Teflon) media Capillary Pressure Gradient (CPG) cartridges prepared during the second years work were evaluated. Results obtained from ground testing at 1-g were compared to those obtained at reduced gravities spanning Martian (13-g), Lunar (16-g) and zero-g. These comparisons clearly demonstrate the relative strength of the CPG phenomena and the efficacy of its application to meet NASAs unique gas-liquid separation (GLS) requirements in non-terrestrial environments.LB modeling software, developed concurrently with the zero-g test effort, was shown to accurately reproduce observed CPG driven gas-liquid separation

  17. Average energy expended per ion pair, exciton enhanced ionization (Jesse effect), electron drift velocity, average electron energy and scintillation in rare gas liquids

    International Nuclear Information System (INIS)

    Doke, T.; Hitachi, A.; Hoshi, Y.; Masuda, K.; Hamada, T.

    1977-01-01

    Precise measurements of W-values, the average energy expended per electron-hole pair in liquid Ar and Xe, were made by the electron-pulse method, and that in liquid Kr by the steady conduction current method. The results showed that the W-values were clearly smaller than those in gaseous Ar, Xe and Kr as predicted by Doke. The results can be explained by the conduction bands which exist in these rare gas liquids as well as in the solid state. The enhanced ionization yield was observed for Xe-doped liquid Ar, and it was attributed to the ionizing excitation transfer process from Ar excitons to doped Xe. This is very similar to the Jesse effect in the gas phase. The saturated value of the enhanced ionization was in good agreement with the theoretical value, and it provides strong evidence for the existence of the exciton states in liquid Ar. Fano factors in liquid Ar, Kr, Xe and Xe-doped liquid Ar have been estimated from the Fano Formula, and they were smaller than those in the gas phase. The drift velocity of electrons in liquid Ar, liquid Ar-gas mixtures and liquid Xe have been measured with gridded ionization chambers. The average electron energy in liquid Ar has been measured. The electron-induced scintillations of liquid Xe and Ar have been studied. (Kato, T.)

  18. Measurement of gas-liquid two-phase flow in micro-pipes by a capacitance sensor.

    Science.gov (United States)

    Ji, Haifeng; Li, Huajun; Huang, Zhiyao; Wang, Baoliang; Li, Haiqing

    2014-11-26

    A capacitance measurement system is developed for the measurement of gas-liquid two-phase flow in glass micro-pipes with inner diameters of 3.96, 2.65 and 1.56 mm, respectively. As a typical flow regime in a micro-pipe two-phase flow system, slug flow is chosen for this investigation. A capacitance sensor is designed and a high-resolution and high-speed capacitance measurement circuit is used to measure the small capacitance signals based on the differential sampling method. The performance and feasibility of the capacitance method are investigated and discussed. The capacitance signal is analyzed, which can reflect the voidage variation of two-phase flow. The gas slug velocity is determined through a cross-correlation technique using two identical capacitance sensors. The simulation and experimental results show that the presented capacitance measurement system is successful. Research work also verifies that the capacitance sensor is an effective method for the measurement of gas liquid two-phase flow parameters in micro-pipes.

  19. Applications of the automatic meter reading techniques at the Brazilian gas domestic market; Application des techniques de releve automatique des compteurs sur le marche domestique Bresilien du gaz

    Energy Technology Data Exchange (ETDEWEB)

    Venancio, J.; Monteiro, F. [Comgas, Sao Paulo (Brazil); D' Oliveira, R.D. [ORBIS, Curitiba (Brazil)

    2000-07-01

    This article will describe applications of the automation and automatic meter reading techniques at the internal gas pipes installations design, considering residential and commercial buildings, and taking in account the tendency of rapid growth of the activities related to the natural gas industry in Brazil, as well as the recently development of new technologies that can be applied with affordable prices. It will be analysed the application of an automatic meter reading technology in a building of several floors in Sao Paulo, which gas installations design is being carried up, with be purpose of making a comparative cost-effectiveness study with the traditional constructive methods applied in Brazil. As a result, it will be purposed a new commercialization model for the gas in Brazil at the residential and commercial market. (authors)

  20. Numerical simulation for gas-liquid two-phase flow in pipe networks

    International Nuclear Information System (INIS)

    Li Xiaoyan; Kuang Bo; Zhou Guoliang; Xu Jijun

    1998-01-01

    The complex pipe network characters can not directly presented in single phase flow, gas-liquid two phase flow pressure drop and void rate change model. Apply fluid network theory and computer numerical simulation technology to phase flow pipe networks carried out simulate and compute. Simulate result shows that flow resistance distribution is non-linear in two phase pipe network

  1. Experimental study of gas-liquid flow local characteristics in rectangular microchannel

    Directory of Open Access Journals (Sweden)

    Bartkus German

    2017-01-01

    Full Text Available Using high-speed video recording and the method of dual laser scanning the gas-liquid flow was investigated in a rectangular microchannel with an aspect ratio of 0.74 (cross section 269×362 μm. The T-mixer was used at the channel’s inlet for the two-phase flow formation. The peculiarity of this work is using a number of liquids (ethanol, distilled water, 40% aqueous ethanol with different physical properties, including surface tension, viscosity, and density, with nitrogen. Experiments were carried out for the vertically upward and horizontal flow. Using laser scanning method the maps of flow patterns were obtained for all mixtures.

  2. Liquid natural gas occupies an increasing position in the energy mix of the USA

    International Nuclear Information System (INIS)

    2002-01-01

    Although the profitability of using liquid natural gas (LNG) depends on the fluctuations of the gas price, LNG will play an increasing role in the ''energy mix'' of the USA. The amount of LNG imported by the USA rose by 175% from 1998 to 2001. There are at present four receiving stations for LNG in the USA and they will probably be extended. Plans to build gas-powered power stations in California will increase the demand for natural gas in the coming years. Several companies have announced their desire to build receiving stations for LNG. There is, however, some opposition from environmentalists

  3. Hydrogen gettering the overpressure gas from highly radioactive liquids

    International Nuclear Information System (INIS)

    Riley, D.L.; Schicker, J.R.

    1996-04-01

    Remediation of current inventories of high-activity radioactive liquid waste (HALW) requires transportation of Type-B quantities of radioactive material, possibly up to several hundred liters. However, the only currently certified packaging is limited to quantities of 50 ml (0.01 gal) quantities of Type-B radioactive liquid. Efforts are under way to recertify the existing packaging to allow the shipment of up to 4 L (1.1 gal) of Type-B quantities of HALW, but significantly larger packaging could be needed in the future. Scoping studies and preliminary designs have identified the feasibility of retrofitting an insert into existing casks, allowing the transport of up to 380 L (100 gal) of HALW. However, the insert design and ultimate certification strategy depend heavily on the gas-generating attributes of the HALW. A non-vented containment vessel filled with HALW, in the absence of any gas-mitigation technologies, poses a deflagration threat and, therefore, gas generation, specifically hydrogen generation, must be reliably controlled during all phases of transportation. Two techniques are available to mitigate hydrogen accumulation: recombiners and getters. Getters have an advantage over recombiners in that oxides are not required to react with the hydrogen. A test plan was developed to evaluate three forms of getter material in the presence of both simulated HALW and the gases that are produced by the HALW. These tests demonstrated that getters can react with hydrogen in the presence of simulated waste and in the presence of several other gases generated by the HALW, such as nitrogen, ammonia, nitrous oxide, and carbon monoxide. Although the use of such a gettering system has been shown to be technically feasible, only a preliminary design for its use has been completed. No further development is planned until the requirement for bulk transport of Type-B quantities of HALW is more thoroughly defined

  4. Kinetic energy and added mass of hydrodynamically interacting gas bubbles in liquid

    NARCIS (Netherlands)

    Kok, Jacobus B.W.

    1988-01-01

    By averaging the basic equations on microscale, expressions are derived for the effective added mass density and the kinetic energy density of a mixture of liquid and gas bubbles. Due to hydrodynamic interaction between the bubbles there appears to be a difference between the effective added mass

  5. GAS payload no. G-025: Study of liquid sloshing behaviour in microgravity

    Science.gov (United States)

    Gilbert, C. R.

    1986-01-01

    The Get Away Special (GAS) G-025, which flew on shuttle Mission 51-G, examined the behavior of a liquid in a tank under microgravity conditions. The experiment is representative of phenomena occurring in satellite tanks with liquid propellants. A reference fluid in a hemispherical model tank will be subjected to linear acceleration inputs of known levels and frequencies, and the dynamic response of the tank liquid system was recorded. Preliminary analysis of the flight data indicates that the experiment functioned perfectly. The results will validate and refine mathematical models describing the dynamic characteristics of tank-fluid systems. This will in turn support the development of future spacecraft tanks, in particular the design of propellant management devices for surface tension tanks.

  6. Automatic analyzing device for chlorine ion

    International Nuclear Information System (INIS)

    Sugibayashi, Shinji; Morikawa, Yoshitake; Fukase, Kazuo; Kashima, Hiromasa.

    1997-01-01

    The present invention provides a device of automatically analyzing a trance amount of chlorine ions contained in feedwater, condensate and reactor water of a BWR type power plant. Namely, zero-adjustment or span calibration in this device is conducted as follows. (1) A standard chlorine ion liquid is supplied from a tank to a mixer by a constant volume pump, and the liquid is diluted and mixed with purified water to form a standard liquid. (2) The pH of the standard liquid is adjusted by a pH adjuster. (3) The standard liquid is supplied to an electrode cell to conduct zero adjustment or span calibration. Chlorine ions in a specimen are measured by the device of the present invention as follows. (1) The specimen is supplied to a head tank through a line filter. (2) The pH of the specimen is adjusted by a pH adjuster. (3) The specimen is supplied to an electrode cell to electrically measure the concentration of the chlorine ions in the specimen. The device of the present invention can automatically analyze trance amount of chlorine ions at a high accuracy, thereby capable of improving the sensitivity, reducing an operator's burden and radiation exposure. (I.S.)

  7. Automatic Web-Based, Radio-Network System To Monitor And Control Equipment For Investigating Gas Flux At Water - Air Interfaces

    Science.gov (United States)

    Duc, N. T.; Silverstein, S.; Wik, M.; Beckman, P.; Crill, P. M.; Bastviken, D.; Varner, R. K.

    2015-12-01

    Aquatic ecosystems are major sources of greenhouse gases (GHG). Robust measurements of natural GHG emissions are vital for evaluating regional to global carbon budgets and for assessing climate feedbacks on natural emissions to improve climate models. Diffusive and ebullitive (bubble) transport are two major pathways of gas release from surface waters. To capture the high temporal variability of these fluxes in a well-defined footprint, we designed and built an inexpensive automatic device that includes an easily mobile diffusive flux chamber and a bubble counter, all in one. Besides a function of automatically collecting gas samples for subsequent various analyses in the laboratory, this device utilizes low cost CO2 sensor (SenseAir, Sweden) and CH4 sensor (Figaro, Japan) to measure GHG fluxes. To measure the spatial variability of emissions, each of the devices is equipped with an XBee module to enable a local radio communication DigiMesh network for time synchronization and data readout at a server-controller station on the lakeshore. Software of this server-controller is operated on a low cost Raspberry Pi computer which has a 3G connection for remote monitoring - controlling functions from anywhere in the world. From field studies in Abisko, Sweden in summer 2014 and 2015, the system has resulted in measurements of GHG fluxes comparable to manual methods. In addition, the deployments have shown the advantage of a low cost automatic network system to study GHG fluxes on lakes in remote locations.

  8. Reactor for tracking catalyst nanoparticles in liquid at high temperature under a high-pressure gas phase with X-ray absorption spectroscopy.

    Science.gov (United States)

    Nguyen, Luan; Tao, Franklin Feng

    2018-02-01

    Structure of catalyst nanoparticles dispersed in liquid phase at high temperature under gas phase of reactant(s) at higher pressure (≥5 bars) is important for fundamental understanding of catalytic reactions performed on these catalyst nanoparticles. Most structural characterizations of a catalyst performing catalysis in liquid at high temperature under gas phase at high pressure were performed in an ex situ condition in terms of characterizations before or after catalysis since, from technical point of view, access to the catalyst nanoparticles during catalysis in liquid phase at high temperature under high pressure reactant gas is challenging. Here we designed a reactor which allows us to perform structural characterization using X-ray absorption spectroscopy including X-ray absorption near edge structure spectroscopy and extended X-ray absorption fine structure spectroscopy to study catalyst nanoparticles under harsh catalysis conditions in terms of liquid up to 350 °C under gas phase with a pressure up to 50 bars. This reactor remains nanoparticles of a catalyst homogeneously dispersed in liquid during catalysis and X-ray absorption spectroscopy characterization.

  9. Low Cost Chemical Feedstocks Using an Improved and Energy Efficient Natural Gas Liquid (NGL) Removal Process, Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Howard, S.; Lu, Yingzhong

    2012-08-10

    The overall objective of this project is to develop a new low-cost and energy efficient Natural Gas Liquid (NGL) recovery process - through a combination of theoretical, bench-scale and pilot-scale testing - so that it could be offered to the natural gas industry for commercialization. The new process, known as the IROA process, is based on U.S. patent No. 6,553,784, which if commercialized, has the potential of achieving substantial energy savings compared to currently used cryogenic technology. When successfully developed, this technology will benefit the petrochemical industry, which uses NGL as feedstocks, and will also benefit other chemical industries that utilize gas-liquid separation and distillation under similar operating conditions. Specific goals and objectives of the overall program include: (i) collecting relevant physical property and Vapor Liquid Equilibrium (VLE) data for the design and evaluation of the new technology, (ii) solving critical R&D issues including the identification of suitable dehydration and NGL absorbing solvents, inhibiting corrosion, and specifying proper packing structure and materials, (iii) designing, construction and operation of bench and pilot-scale units to verify design performance, (iv) computer simulation of the process using commercial software simulation platforms such as Aspen-Plus and HYSYS, and (v) preparation of a commercialization plan and identification of industrial partners that are interested in utilizing the new technology. NGL is a collective term for C2+ hydrocarbons present in the natural gas. Historically, the commercial value of the separated NGL components has been greater than the thermal value of these liquids in the gas. The revenue derived from extracting NGLs is crucial to ensuring the overall profitability of the domestic natural gas production industry and therefore of ensuring a secure and reliable supply in the 48 contiguous states. However, rising natural gas prices have dramatically reduced

  10. Determination of trihalomethanes in waters by ionic liquid-based single drop microextraction/gas chromatographic/mass spectrometry.

    Science.gov (United States)

    Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2008-10-31

    A simple, rapid, solventless method for the determination of trihalomethanes (THMs) (chloroform, bromodichloromethane, dibromochloromethane and bromoform) in water samples is presented. The analytes are extracted from the headspace of the aqueous matrix into a 2 microL drop of the ionic liquid 1-octyl-3-methyl-imidazolium hexafluorophosphate working at 30 degrees C for 30 min. The separation and detection of the target compounds is accomplished by gas chromatography/mass spectrometry owing to the use of an interface that efficiently transfers the analytes extracted in the ionic liquid drop to the gas chromatograph while preventing the ionic liquid from entering the column. The detection limits obtained are below the values compelled by the legislation, ranging from 0.5 microg L(-1) for chloroform and bromodichloromethane to 0.9 microg L(-1) for dibromochloromethane. The use of ionic liquid in the extraction procedure avoids the use of organic solvents and leads to relative standard deviations that range from 3.1% to 4.8%.

  11. Nanocrystalline SnO2:F Thin Films for Liquid Petroleum Gas Sensors

    Directory of Open Access Journals (Sweden)

    Sutichai Chaisitsak

    2011-07-01

    Full Text Available This paper reports the improvement in the sensing performance of nanocrystalline SnO2-based liquid petroleum gas (LPG sensors by doping with fluorine (F. Un-doped and F-doped tin oxide films were prepared on glass substrates by the dip-coating technique using a layer-by-layer deposition cycle (alternating between dip-coating a thin layer followed by a drying in air after each new layer. The results showed that this technique is superior to the conventional technique for both improving the film thickness uniformity and film transparency. The effect of F concentration on the structural, surface morphological and LPG sensing properties of the SnO2 films was investigated. Atomic Force Microscopy (AFM and X-ray diffraction pattern measurements showed that the obtained thin films are nanocrystalline SnO2 with nanoscale-textured surfaces. Gas sensing characteristics (sensor response and response/recovery time of the SnO2:F sensors based on a planar interdigital structure were investigated at different operating temperatures and at different LPG concentrations. The addition of fluorine to SnO2 was found to be advantageous for efficient detection of LPG gases, e.g., F-doped sensors are more stable at a low operating temperature (300 °C with higher sensor response and faster response/recovery time, compared to un-doped sensor materials. The sensors based on SnO2:F films could detect LPG even at a low level of 25% LEL, showing the possibility of using this transparent material for LPG leak detection.

  12. Local gas- and liquid-phase measurements for air-water two-phase flows in a rectangular channel

    International Nuclear Information System (INIS)

    Zhou, X.; Sun, X.; Williams, M.; Fu, Y.; Liu, Y.

    2014-01-01

    Local gas- and liquid-phase measurements of various gas-liquid two-phase flows, including bubbly, cap-bubbly, slug, and churn-turbulent flows, were performed in an acrylic vertical channel with a rectangular cross section of 30 mm x 10 mm and height of 3.0 m. All the measurements were carried out at three measurement elevations along the flow channel, with z/D h = 9, 72, and 136, respectively, to study the flow development. The gas-phase velocity, void fraction, and bubble number frequency were measured using a double-sensor conductivity probe. A high-speed imaging system was utilized to perform the flow regime visualization and to provide additional quantitative information of the two-phase flow structure. An image processing scheme was developed to obtain the gas-phase velocity, void fraction, Sauter mean diameter, bubble number density, and interfacial area concentration. The liquid-phase velocity and turbulence measurements were conducted using a particle image velocimetry-planar laser-induced fluorescence (PIV-PLIF) system, which enables whole-field and high-resolution data acquisition. An optical phase separation method, which uses fluorescent particles and optical filtration technique, is adopted to extract the velocity information of the liquid phase. An image pre-processing scheme is imposed on the raw PIV images acquired to remove noises due to the presence of bubble residuals and optically distorted particles in the images captured by the PIV-PLIF system. Due to the better light access and less bubble distortion in the narrow rectangular channel, the PIV-PLIF system were able to perform reasonably well in flows of even higher void fractions as compared to the situations with circular pipe test sections. The flow conditions being studied covered various flow regime transitions, void fractions, and liquid-phase flow Reynolds numbers. The obtained experimental data can also be used to validate two-phase CFD results. (author)

  13. Experimental investigation of two-phase gas-liquid flow in microchannel with T-junction

    Science.gov (United States)

    Bartkus, German; Kozulin, Igor; Kuznetsov, Vladimir

    2017-10-01

    Using high-speed video recording and the method of dual laser scanning the gas-liquid flow was investigated in rectangular microchannels with an aspect ratio of 2.35 and 1.26. Experiments were earned out for the vertical flow of ethanol-nitrogen mixture in a microchannel with a cross section of 553×235 µm and for the horizontal flow of water-nitrogen mixture in a microchannel with a cross section of 315×250 µm. The T-mixer was used at the channel's inlet for gas-liquid flow formation. It was observed that elongated bubble, transition, and annular flows are the main regimes for a microchannel with a hydraulic diameter substantially less than the capillary constant. Using laser scanning, the maps of flow regimes for ethanol-nitrogen and water-nitrogen mixtures were obtained and discussed.

  14. Ecoulements diphasiques gaz-liquide à poches et à bouchons en conduites Two-Phase Gas-Liquid Slug Flow in Pipes

    Directory of Open Access Journals (Sweden)

    Ferschneider G.

    2006-11-01

    Full Text Available Les écoulements diphasiques gaz-liquide ont été étudiés afin de contribuer à développer des modèles de calculs prédictifs des pertes de charge dans les conduites de production des bruts pétroliers. Les expériences nécessaires ont été réalisées sur la boucle diphasique de Boussens dans les conditions suivantes représentatives des conditions industrielles : diamètre 6 , longueur 120 m, disposition de la conduite horizontale ou faiblement ascendante, couple de fluide gaz naturel-huile légère. Le gradient de pression, le contenu global, et la distribution locale des phases ont été mesurés. Le traitement des équations de conservation phasique intégrées sur la section par différents types de moyennes a permis de développer un modèle cellulaire qui inclue un nombre limité d'équations constitutives nécessaires à sa fermeture. Ce modèle prédétermine convenablement le gradient de pression, le contenu gaz global et la longueur des poches et des bouchons. Two-phase gas-liquid flows were analyzed so as to develop models for prediction of pressure drops in crude-oil production lines. The experiments were performed on the two-phase loop at Boussens under the following representative industrial conditions: 6 diameter, 120 m length, horizontal or slightly rising pipe, couple of fluids natural gas and light oil. The pressure gradient, average content and local phase distribution were measured. Conservation phase equations integrated along the cross-section were processed by different time-averaged operators so as to develop a cellular model including a limited number of constitutive equations required for its closure. This model suitably predetermines the pressure gradient, the average gas content and the length of gas and liquid slug.

  15. Review of online coupling of sample preparation techniques with liquid chromatography.

    Science.gov (United States)

    Pan, Jialiang; Zhang, Chengjiang; Zhang, Zhuomin; Li, Gongke

    2014-03-07

    Sample preparation is still considered as the bottleneck of the whole analytical procedure, and efforts has been conducted towards the automation, improvement of sensitivity and accuracy, and low comsuption of organic solvents. Development of online sample preparation techniques (SP) coupled with liquid chromatography (LC) is a promising way to achieve these goals, which has attracted great attention. This article reviews the recent advances on the online SP-LC techniques. Various online SP techniques have been described and summarized, including solid-phase-based extraction, liquid-phase-based extraction assisted with membrane, microwave assisted extraction, ultrasonic assisted extraction, accelerated solvent extraction and supercritical fluids extraction. Specially, the coupling approaches of online SP-LC systems and the corresponding interfaces have been discussed and reviewed in detail, such as online injector, autosampler combined with transport unit, desorption chamber and column switching. Typical applications of the online SP-LC techniques have been summarized. Then the problems and expected trends in this field are attempted to be discussed and proposed in order to encourage the further development of online SP-LC techniques. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. A Novel Acoustic Liquid Level Determination Method for Coal Seam Gas Wells Based on Autocorrelation Analysis

    Directory of Open Access Journals (Sweden)

    Ximing Zhang

    2017-11-01

    Full Text Available In coal seam gas (CSG wells, water is periodically removed from the wellbore in order to keep the bottom-hole flowing pressure at low levels, facilitating the desorption of methane gas from the coal bed. In order to calculate gas flow rate and further optimize well performance, it is necessary to accurately monitor the liquid level in real-time. This paper presents a novel method based on autocorrelation function (ACF analysis for determining the liquid level in CSG wells under intense noise conditions. The method involves the calculation of the acoustic travel time in the annulus and processing the autocorrelation signal in order to extract the weak echo under high background noise. In contrast to previous works, the non-linear dependence of the acoustic velocity on temperature and pressure is taken into account. To locate the liquid level of a coal seam gas well the travel time is computed iteratively with the non-linear velocity model. Afterwards, the proposed method is validated using experimental laboratory investigations that have been developed for liquid level detection under two scenarios, representing the combination of low pressure, weak signal, and intense noise generated by gas flowing and leakage. By adopting an evaluation indicator called Crest Factor, the results have shown the superiority of the ACF-based method compared to Fourier filtering (FFT. In the two scenarios, the maximal measurement error from the proposed method was 0.34% and 0.50%, respectively. The latent periodic characteristic of the reflected signal can be extracted by the ACF-based method even when the noise is larger than 1.42 Pa, which is impossible for FFT-based de-noising. A case study focused on a specific CSG well is presented to illustrate the feasibility of the proposed approach, and also to demonstrate that signal processing with autocorrelation analysis can improve the sensitivity of the detection system.

  17. Development of robust fluorinated TiO2/PVDF composite hollow fiber membrane for CO2 capture in gas-liquid membrane contactor

    Science.gov (United States)

    Lin, Yuqing; Xu, Yilin; Loh, Chun Heng; Wang, Rong

    2018-04-01

    Gas-liquid membrane contactor (GLMC) is a promising method to attain high efficiency for CO2 capture from flue gas, biogas and natural gas. However, membranes used in GLMC are prone to pore wetting due to insufficient hydrophobicity and low chemical resistance, resulting in significant increase in mass transfer resistance. To mitigate this issue, inorganic-organic fluorinated titania/polyvinylidene fluoride (fTiO2/PVDF) composite hollow fiber (HF) membranes was prepared via facile in-situ vapor induced hydrolyzation method, followed by hydrophobic modification. The proposed composite membranes were expected to couple the superb chemical stability of inorganic and high permeability/low cost of organic materials. The continuous fTiO2 layer deposited on top of PVDF substrate was found to possess a tighter microstructure and better hydrophobicity, which effectively prevented the membrane from wetting and lead to a high CO2 absorption flux (12.7 × 10-3 mol m-2 s-1). In a stability test with 21-day operation of GLMC using 1M monoethanolamine (MEA) as the absorbent, the fTiO2/PVDF membrane remained to be intact with a CO2 absorption flux decline of ∼16%, while the pristine PVDF membrane suffered from a flux decline of ∼80% due to membrane damage. Overall, this work provides an insight into the preparation of high-quality inorganic/organic composite HF membranes for CO2 capture in GLMC application.

  18. Study and modeling of the evolution of gas-liquid partitioning of hydrogen sulfide in model solutions simulating winemaking fermentations.

    Science.gov (United States)

    Mouret, Jean-Roch; Sablayrolles, Jean-Marie; Farines, Vincent

    2015-04-01

    The knowledge of gas-liquid partitioning of aroma compounds during winemaking fermentation could allow optimization of fermentation management, maximizing concentrations of positive markers of aroma and minimizing formation of molecules, such as hydrogen sulfide (H2S), responsible for defects. In this study, the effect of the main fermentation parameters on the gas-liquid partition coefficients (Ki) of H2S was assessed. The Ki for this highly volatile sulfur compound was measured in water by an original semistatic method developed in this work for the determination of gas-liquid partitioning. This novel method was validated and then used to determine the Ki of H2S in synthetic media simulating must, fermenting musts at various steps of the fermentation process, and wine. Ki values were found to be mainly dependent on the temperature but also varied with the composition of the medium, especially with the glucose concentration. Finally, a model was developed to quantify the gas-liquid partitioning of H2S in synthetic media simulating must to wine. This model allowed a very accurate prediction of the partition coefficient of H2S: the difference between observed and predicted values never exceeded 4%.

  19. Automatic-Control System for Safer Brazing

    Science.gov (United States)

    Stein, J. A.; Vanasse, M. A.

    1986-01-01

    Automatic-control system for radio-frequency (RF) induction brazing of metal tubing reduces probability of operator errors, increases safety, and ensures high-quality brazed joints. Unit combines functions of gas control and electric-power control. Minimizes unnecessary flow of argon gas into work area and prevents electrical shocks from RF terminals. Controller will not allow power to flow from RF generator to brazing head unless work has been firmly attached to head and has actuated micro-switch. Potential shock hazard eliminated. Flow of argon for purging and cooling must be turned on and adjusted before brazing power applied. Provision ensures power not applied prematurely, causing damaged work or poor-quality joints. Controller automatically turns off argon flow at conclusion of brazing so potentially suffocating gas does not accumulate in confined areas.

  20. Study of Co-Current and Counter-Current Gas-Liquid Two-Phase Flow Through Packed Bed in Microgravity

    Science.gov (United States)

    Revankar, Shripad T.

    2002-11-01

    The main goal of the project is to obtain new experimental data and development of models on the co-current and counter-current gas-liquid two-phase flow through a packed bed in microgravity and characterize the flow regime transition, pressure drop, void and interfacial area distribution, and liquid hold up. Experimental data will be obtained for earth gravity and microgravity conditions. Models will be developed for the prediction of flow regime transition, void fraction distribution and interfacial area concentration, which are key parameters to characterize the packed bed performance. Thus the specific objectives of the proposed research are to: (1) Develop experiments for the study of the gas liquid two-phase flow through the packed bed with three different flow combinations: co-current down flow, co-current upflow and counter current flow. (2) Develop pore scale and bed scale two-phase instrumentation for measurement of flow regime transition, void distribution and gas-liquid interfacial area concentration in the packed bed. (3) Obtain database on flow regime transition, pressure drop, void distribution, interfacial area concentration and liquid hold up as a function of bed characteristics such as bed particle size, porosity, and liquid properties such as viscosity and surface tension. (4) Develop mathematical model for flow regime transition, void fraction distribution and interfacial area concentration for co-current gas-liquid flow through the porous bed in gravity and micro gravity conditions.(4) Develop mathematical model for the flooding phenomena in counter-current gas-liquid flow through the porous bed in gravity and micro gravity conditions. The present proposal addresses the most important topic of HEDS-specific microgravity fluid physics research identified by NASA 's one of the strategic enterprises, OBPR Enterprise. The proposed project is well defined and makes efficient use of the ground-based parabolic flight research aircraft facility. The

  1. New developments in adsorptive gas and water purification. Lectures and posters; Neue Entwicklungen zur adsorptiven Gas- und Wasserreinigung. Beitraege und Poster

    Energy Technology Data Exchange (ETDEWEB)

    Heschel, W [comp.

    2000-07-01

    The conference discussed the following issues: Activated carbon preparation and selective pretreatment, lignite adsorbers, purification of liquid effluents containing heavy metals and/or salts, purification of off-gas and natural gas, desulphurisation, regeneration of adsorbents. [German] Die Tagung beschaeftigte sich u.a. mit den Themen: Aktivkohle Herstellung und Vorbehandlung zum gezielten Einsatz, Adsorber aus Braunkohle, Reinigung von Schwermetall- und Salz-haltigem Abwasser, Reinigung von Abgasen und Erdgas, Entschwefelung, und der Regenerierung der Adsorbentien.

  2. Pressurized liquid extraction-assisted mussel cytosol preparation for the determination of metals bound to metallothionein-like proteins

    International Nuclear Information System (INIS)

    Santiago-Rivas, Sandra; Moreda-Pineiro, Antonio; Bermejo-Barrera, Pilar; Moreda-Pineiro, Jorge; Alonso-Rodriguez, Elia; Muniategui-Lorenzo, Soledad; Lopez-Mahia, Purificacion; Prada-Rodriguez, Dario

    2007-01-01

    The possibilities of pressurized liquid extraction (PLE) have been novelty tested to assist the cytosol preparation from wet mussel soft tissue before the determination of metals bound to metallothionein-like proteins (MLPs). Results obtained after PLE were compared with those obtained after a classical blending procedure for mussel cytosolic preparation. Isoforms MLP-1 (retention time of 4.1 min) and MLP-2 (retention time of 7.4 min) were separated by anion exchange high-performance liquid chromatography (HPLC) and the concentrations of Ba, Cu, Mn, Sr and Zn bound to MLP isoforms were directly measured by inductively coupled plasma-atomic emission spectrometry (ICP-OES) as a multi-element detector. The optimized PLE-assisted mussel cytosol preparation has consisted of one extraction cycle at room temperature and 1500 psi for 2 min. Since separation between the solid mussel residue and the extract (cytosol) is performed by the PLE system, the cytosol preparation method is faster than conventional cytosol preparation methods by cutting/blending using Ultraturrax or Stomacher devices

  3. Prediction of turbulent mixing rates of both gas and liquid phases between adjacent subchannels in a two-phase slug-churn flow

    International Nuclear Information System (INIS)

    Kawahara, A.; Sadatomi, M.; Tomino, T.; Sato, Y.

    1998-01-01

    This paper presents a slug-churn flow model for predicting turbulent mixing rates of both gas and liquid phase between adjacent subchannels in a BWR fuel rod bundle. In the model, the mixing rate of the liquid phase is calculated as the sum of the three components, i.e., turbulent diffusion, convective transfer and pressure difference fluctuations between the subchannels. The compenents of turbulent diffusion and convective transfer are calculated from Sadatomi et al.'s (1996) method, applicable to single-phase turbulent mixing by considering the effect of the increment of liquid velocity due to the presence of gas phase. The component of the pressure difference fluctuations is evaluated from a newly developed correlations. The mixing rate of the gas phase, on the other side, is calculated from a simple relation of mixing rate between gas and liquid phases. The validity of the proposed model has been confirmed with the turbulent mixing rates data of Rudzinski et al. as well as the present authors

  4. A numerical study on the influence of gas-liquid two phase flow on the rotary pump performances

    International Nuclear Information System (INIS)

    Miao, T C; Liu, Y Y; Zhao, F; Wang, L Q

    2013-01-01

    Rotary pump can be used in many fields because of its strong self-priming ability. Many factors may cause the medium in rotary pump system containing gas-liquid two phase. And the suction capacity of rotary pump will decrease sharply in these situations. To study the internal flow mechanism of rotary pump when transporting medium containing gas, the gas-liquid two phase flow in the rotary pump system has been simulated using VOF model under different gas fractions. And the interaction between rotary pump and the pipeline has been considered. The simulation results coincide well with the theoretical calculation results, and the distribution of the flow field match well with the Mandhane flow pattern map. The main conclusions are as follows: with the increase of gas fraction, the flow pattern in the pipeline has the following evolutionary trend (bubble – plug – slug – wavy), and the suction capacity of the pump will decrease. It is mainly because gas medium can fill the partial vacuum produced by the rotor motion easily and is easier to have backflow

  5. Preparation and characterization of copper-graphite composites by electrical explosion of wire in liquid.

    Science.gov (United States)

    Bien, T N; Gul, W H; Bac, L H; Kim, J C

    2014-11-01

    Copper-graphite nanocomposites containing 5 vol.% graphite were prepared by a powder metallurgy route using an electrical wire explosion (EEW) in liquid method and spark plasma sintering (SPS) process. Graphite rods with a 0.3 mm diameter and copper wire with a 0.2 mm diameter were used as raw materials for EEWin liquid. To compare, a pure copper and copper-graphite mixture was also prepared. The fabricated graphite was in the form of a nanosheet, onto which copper particles were coated. Sintering was performed at 900 degrees C at a heating rate of 30 degrees C/min for 10 min and under a pressure of 70 MPa. The density of the sintered composite samples was measured by the Archimedes method. A wear test was performed by a ball-on-disc tribometer under dry conditions at room temperature in air. The presence of graphite effectively reduced the wear of composites. The copper-graphite nanocomposites prepared by EEW had lower wear rates than pure copper material and simple mixed copper-graphite.

  6. Study on fine particles influence on sodium sulfite and oxygen gas-liquid reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Shuchang; Zhao, Bo; Wang, Shujuan; Zhuo, Yuqun; Chen, Changhe [Tsinghua Univ., Beijing (China). Dept. of Thermal Engineering; Ministry of Education, Beijing (China). Key Lab. for Thermal Science and Power Engineering

    2013-07-01

    Wet limestone scrubbing is the most common flue gas desulfurization process for control of sulfur dioxide emissions from the combustion of fossil fuels, and forced oxidation is a key part of the reaction. During the reaction which controlled by gas-liquid mass transfer, the fine particles' characteristic, size, solid loading and temperature has a great influence on gas-liquid mass transfer. In the present work is to explain how these factors influence the reaction between Na{sub 2}SO{sub 3} and O{sub 2} and find the best react conditions through experiment. The oxidation rate was experimentally studied by contacting pure oxygen with a sodium sulfite solution with active carbon particle in a stirred tank, and the system pressure drop was record by the pressure sensor. At the beginning the pressure is about 215 kPa and Na{sub 2}SO{sub 3} is about 0.5mol/L. The temperature is 40, 50, 60, 70, 80 C. Compare the results of no particles included, we can conclude that high temperature, proper loadings and smaller particles resulting in higher mass transfer coefficients k{sub L}.

  7. Natural gas as a means of heating liquids

    International Nuclear Information System (INIS)

    Pronovost, M.

    1996-01-01

    Liquids can now be heated at low temperature directly at the point of end use, thanks to flexible and customized natural gas technologies. For customers these advances eliminate the need for poorly-performing central boilers, while investors can look forward to a reduction in the period of time needed to recover investments. Decentralization of the production offers many challenges to industries that have to produce vast quantities of hot water, among them increased efficiency, direct and speedy response to demands for energy, and reduced maintenance expenses. Consumers can also look forward to reduced need for energy, hence better control of the energy dollar. 2 figs

  8. Improvement of mineral oil saturated and aromatic hydrocarbons determination in edible oil by liquid-liquid-gas chromatography with dual detection.

    Science.gov (United States)

    Zoccali, Mariosimone; Barp, Laura; Beccaria, Marco; Sciarrone, Danilo; Purcaro, Giorgia; Mondello, Luigi

    2016-02-01

    Mineral oils, which are mainly composed of saturated hydrocarbons and aromatic hydrocarbons, are widespread food contaminants. Liquid chromatography coupled to gas chromatography with flame ionization detection represents the method of choice to determine these two families. However, despite the high selectivity of this technique, the presence of olefins (particularly squalene and its isomers) in some samples as in olive oils, does not allow the correct quantification of the mineral oil aromatic hydrocarbons fraction, requiring additional off-line tools to eliminate them. In the present research, a novel on-line liquid chromatography coupled to gas chromatography method is described for the determination of hydrocarbon contamination in edible oils. Two different liquid chromatography columns, namely a silica one (to retain the bulk of the matrix) and a silver-ion one (which better retains the olefins), were coupled in series to obtain the mineral oil aromatic hydrocarbons hump free of interfering peaks. Furthermore, the use of a simultaneous dual detection, flame ionization detector and triple quadrupole mass spectrometer allowed us not only to quantify the mineral oil contamination, but also to evaluate the presence of specific markers (i.e. hopanes) to confirm the petrogenic origin of the contamination. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Gas--liquid equilibria in mixtures of hydrogen and thianaphthene

    Energy Technology Data Exchange (ETDEWEB)

    Sebastian, H M; Simnick, J J; Lin, H M; Chao, K C

    1978-12-01

    Gas--liquid equilibrium conditions in binary mixtures of hydrogen and thianaphthene were experimentally determined at temperature of 190 to 430/sup 0/C and pressures to 250 atm in a flow apparatus. The same apparatus was also employed to measure the vapor pressure of thianaphthene. Comparisons of the new mixture data with Chao--Seader and Grayson--Streed correlations show that both correlations predict the thianaphthene equilibrium ratios well but are in error by up to about 45 and 35% respectively for K-values of hydrogen. 4 figures, 2 tables.

  10. Increased prandial air swallowing and postprandial gas-liquid reflux among patients refractory to proton pump inhibitor therapy

    NARCIS (Netherlands)

    Bravi, Ivana; Woodland, Philip; Gill, Ravinder S.; Al-Zinaty, Mohannad; Bredenoord, Albert J.; Sifrim, Daniel

    2013-01-01

    Many patients with gastroesophageal reflux disease (GERD) have persistent reflux despite treatment with proton pump inhibitors (PPIs). Mixed gas-liquid reflux events are more likely to be perceived as symptomatic. We used esophageal impedance monitoring to investigate whether esophageal gas is

  11. Gas-Liquid Two-Phase Flows Through Packed Bed Reactors in Microgravity

    Science.gov (United States)

    Motil, Brian J.; Balakotaiah, Vemuri

    2001-01-01

    The simultaneous flow of gas and liquid through a fixed bed of particles occurs in many unit operations of interest to the designers of space-based as well as terrestrial equipment. Examples include separation columns, gas-liquid reactors, humidification, drying, extraction, and leaching. These operations are critical to a wide variety of industries such as petroleum, pharmaceutical, mining, biological, and chemical. NASA recognizes that similar operations will need to be performed in space and on planetary bodies such as Mars if we are to achieve our goals of human exploration and the development of space. The goal of this research is to understand how to apply our current understanding of two-phase fluid flow through fixed-bed reactors to zero- or partial-gravity environments. Previous experiments by NASA have shown that reactors designed to work on Earth do not necessarily function in a similar manner in space. Two experiments, the Water Processor Assembly and the Volatile Removal Assembly have encountered difficulties in predicting and controlling the distribution of the phases (a crucial element in the operation of this type of reactor) as well as the overall pressure drop.

  12. Data compilation report: Gas and liquid samples from K West Basin fuel storage canisters

    International Nuclear Information System (INIS)

    Trimble, D.J.

    1995-01-01

    Forty-one gas and liquid samples were taken from spent fuel storage canisters in the K West Basin during a March 1995 sampling campaign. (Spent fuel from the N Reactor is stored in sealed canisters at the bottom of the K West Basin.) A description of the sampling process, gamma energy analysis data, and quantitative gas mass spectroscopy data are documented. This documentation does not include data analysis

  13. Conversion of Mixed Plastic Wastes (High Density Polyethylene and Polypropylene) into Liquid Fuel

    International Nuclear Information System (INIS)

    Chaw Su Su Hmwe; Tint Tint Kywe; Moe Moe Kyaw

    2010-12-01

    In this study, mixed plastic wastes were converted into liquid fuels. Mixed plastic wastes used were high density polyethylene (HDPE) and polypropylene (PP). The pyrolysis of mixed plastic waste to liquid fuel was carried out with and without prepared zeolite catalyst.The catalyst was characterized by X-ray Diffraction (XRD). This catalyst was pre-treated for activation. The experiments were carried out at temperature range of 350-410C.Physical properties (density, kinematic, viscosity,refractive index)of prepared liquid fuel samples were measured. From this study, yields of liquid fuel and gas fuel were found to be 41-64% and 15-35% respectively. As for by products, char was obtained as the yield percentages from 9 to 14% and wax (yield% - 1 to 14) was formed during pyrolysis.

  14. Recent advances in liquid and gas chromatography methodology for extending coverage of the metabolome.

    Science.gov (United States)

    Haggarty, Jennifer; Burgess, Karl Ev

    2017-02-01

    The metabolome is the complete complement of metabolites (small organic biomolecules). In order to comprehensively understand the effect of stimuli on a biological system, it is important to detect as many of the metabolites within that system as possible. This review briefly describes some new advances in liquid and gas chromatography to improve coverage of the metabolome, including the serial combination of two columns in tandem, column switching and different variations of two-dimensional chromatography. Supercritical fluid chromatography could provide complimentary data to liquid and gas chromatography. Although there have been many recent advancements in the field of metabolomics, it is evident that a combination, rather than a single method, is required to approach full coverage of the metabolome. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Effects of laser fluence and liquid media on preparation of small Ag nanoparticles by laser ablation in liquid

    Science.gov (United States)

    Moura, Caroline Gomes; Pereira, Rafael Santiago Floriani; Andritschky, Martin; Lopes, Augusto Luís Barros; Grilo, João Paulo de Freitas; Nascimento, Rubens Maribondo do; Silva, Filipe Samuel

    2017-12-01

    This study aims to assess a method for preparation of small and highly stable Ag nanoparticles by nanosecond laser ablation in liquid. Effect of liquid medium and laser fluence on the size, morphology and structure of produced nanoparticles has been studied experimentally. Pulses of a Nd:YAG laser of 1064 nm wavelength at 35 ns pulse width at different fluences were employed to irradiate the silver target in different environments (water, ethanol and acetone). The UV-Visible absorption spectra of nanoparticles exhibit surface plasmon resonance absorption peak in the UV region. STEM and TEM micrographs were used to evaluate the size and shape of nanoparticles. The stability of silver colloids in terms of oxidation at different liquid media was analyzed by SAED patterns. The results showed that characteristics of Ag nanoparticles and their production rate were strongly influenced by varying laser fluence and liquid medium. Particles from 2 to 80 nm of diameter were produced using different conditions and no oxidation was found in ethanol and acetone media. This work puts in evidence a promising approach to produce small nanoparticles by using high laser fluence energy.

  16. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Flow characteristics of centrifugal gas-liquid separator. Investigation with air-water two-phase flow experiment

    International Nuclear Information System (INIS)

    Yoneda, Kimitoshi; Inada, Fumio

    2004-01-01

    Air-water two-phase flow experiment was conducted to examine the basic flow characteristics of a centrifugal gas-liquid separator. Vertical transparent test section, which is 4 m in height, was used to imitate the scale of a BWR separator. Flow rate conditions of gas and liquid were fixed at 0.1 m 3 /s and 0.033 m 3 /s, respectively. Radial distributions of two-phase flow characteristics, such as void fraction, gas velocity and bubble chord length, were measured by traversing dual optical void probes in the test section, horizontally. The flow in the standpipe reached to quasi-developed state within the height-to-diameter aspect ratio H/D=10, which in turn can mean the maximum value for an ideal height design of a standpipe. The liquid film in the barrel showed a maximum thickness at 0.5 to 1 m in height from the swirler exit, which was a common result for three different standpipe length conditions, qualitatively and quantitatively. The empirical database obtained in this study would contribute practically to the validation of numerical analyses for an actual separator in a plant, and would also be academically useful for further investigations of two-phase flow in large-diameter pipes. (author)

  18. Interaction of Liquid Film Flow of Direct Vessel Injection Under the Cross Directional Gas Flow

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-sol; Lee, Jae-young [Handong Global University, Pohang (Korea, Republic of); Euh, Dong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In order to obtain a proper scaling law of the flow, local information of the flow was investigated experimentally and also numerically. A series of experiments were conducted in the 1/20 modified linear scaled plate type test rig to analyze a liquid film from ECC water injection through the DVI nozzle to the downcomer wall. The present study investigates liquid film flow generated in a downcomer of direct vessel injection (DVI) system which is employed as an emergency core cooling (ECC) system during a loss of coolant accident in the Korea nuclear power plant APR1400. During the late reflooding, complicated multi-phase flow phenomena including the wavy film flow, film breakup, entrainment, liquid film shift due to interfacial drag and gas jet impingement occur. A confocal chromatic sensor was used to measure the local instantaneous liquid film thickness and a hydraulic jump in the film flow and boundaries of the film flow. It was found that CFD analysis results without surface tension model showed some difference with the data in surface tension dominated flow region. For the interaction between a liquid film and gas shear flow, CFD results make a good agreement with the real liquid film dynamics in the case of low film Reynolds number or low Weber number flow. In the 1/20 scaled plate type experiment and simulation, the deformed spreading profile results seem to accord with each other at the relatively low We and Re regime.

  19. On-line Automated Sample Preparation-Capillary Gas Chromatography for the Analysis of Plasma Samples.

    NARCIS (Netherlands)

    Louter, A.J.H.; van der Wagt, R.A.C.A.; Brinkman, U.A.T.

    1995-01-01

    An automated sample preparation module, (the automated sample preparation with extraction columns, ASPEC), was interfaced with a capillary gas chromatograph (GC) by means of an on-column interface. The system was optimised for the determination of the antidepressant trazodone in plasma. The clean-up

  20. The nuclear liquid-gas phase transition: Present status and future perspectives

    International Nuclear Information System (INIS)

    Pochodzalla, J.; Imme, G.; Maddalena, V.

    1996-07-01

    More than two decades ago, the van der Waals behavior of the nucleon -nucleon force inspired the idea of a liquid-gas phase transition in nuclear matter. Heavy-ion reactions at relativistic energies offer the unique possibility for studying this phase transition in a finite, hadronic system. A general overview of this subject is given emphasizing the most recent results on nuclear calorimetry. (orig.)