WorldWideScience

Sample records for automatic measuring device

  1. Automatic measuring device for atomic oxygen concentrations (1962); Dispositif de mesure automatique de concentrations d'oxygene atomique (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J; Deiss, M; Mercier, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Within the framework of the activities of the Autonomous Reactor Electronics Section we have developed a device, which renders automatic one type of measurement carried out in the Physical Chemistry Department at the Saclay Research Centre. We define here: - the physico-chemical principle of the apparatus which is adapted to the measurement of atomic oxygen concentrations; - the physical principle of the automatic measurement; - the properties, performance, constitution, use and maintenance of the automatic measurement device. It is concluded that the principle of the automatic device, whose tests have confirmed the estimation of the theoretical performance, could usefully be adapted to other types of measurement. (authors) [French] Dans le cadre des activites de la Section Autonome d'Electronique des Reacteurs, il a ete realise et mis au point un dispositif permettant de rendre automatique un type de mesures effectuees au Departement de Physico-Chimie du C.E.N. SACLAY. On definit ici: - le principe physico-chimique de l'appareillage, adapte a la mesure de concentrations de l'oxygene atomique; - le principe physique de la mesure automatique; - les qualites, performances, constitution, utilisation, et maintenance du dispositif de mesure automatique. Il est porte en conclusion, que le principe du dispositif automatique realise, dont les essais ont sensiblement confirme l'evaluation des performances theoriques, pourrait etre utilement adapte a d'autres types de mesures courantes. (auteurs)

  2. Automatic analyzing device for chlorine ion

    International Nuclear Information System (INIS)

    Sugibayashi, Shinji; Morikawa, Yoshitake; Fukase, Kazuo; Kashima, Hiromasa.

    1997-01-01

    The present invention provides a device of automatically analyzing a trance amount of chlorine ions contained in feedwater, condensate and reactor water of a BWR type power plant. Namely, zero-adjustment or span calibration in this device is conducted as follows. (1) A standard chlorine ion liquid is supplied from a tank to a mixer by a constant volume pump, and the liquid is diluted and mixed with purified water to form a standard liquid. (2) The pH of the standard liquid is adjusted by a pH adjuster. (3) The standard liquid is supplied to an electrode cell to conduct zero adjustment or span calibration. Chlorine ions in a specimen are measured by the device of the present invention as follows. (1) The specimen is supplied to a head tank through a line filter. (2) The pH of the specimen is adjusted by a pH adjuster. (3) The specimen is supplied to an electrode cell to electrically measure the concentration of the chlorine ions in the specimen. The device of the present invention can automatically analyze trance amount of chlorine ions at a high accuracy, thereby capable of improving the sensitivity, reducing an operator's burden and radiation exposure. (I.S.)

  3. Automatic exchange unit for control rod drive device

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To enable automatic reoperation and continuation without external power interruption remedy device at the time of recovering the interrupted power soruce during automatic positioning operation. Constitution: In case of an automatic exchange unit for a control rod drive device of the control type for setting the deviation between the positioning target position and the present position of the device to zero, the position data of the drive device of the positioning target value of the device is automatically read, and an interlock of operation inhibit is applied to a control system until the data reading is completed and automatic operation start or restart conditions are sequentially confirmed. After the confirmation, the interlock is released to start the automatic operation or reoperation. Accordingly, the automatic operation can be safely restarted and continued. (Yoshihara, H.)

  4. Development of an automatic sampling device for the continuous measurement of atmospheric carbonyls compounds

    International Nuclear Information System (INIS)

    Perraud, V.

    2007-12-01

    Two sampling strategies were studied to develop an automatic instrument for the continuous measurement of atmospheric carbonyl compounds. Because of its specificity towards carbonyls compounds, sampling by using a transfer of gaseous phase in a liquid phase associated with a simultaneous chemical derivatization of the trapped compounds was first studied. However, this method do not allow a quantitative sampling of all studied carbonyl compounds, nor a continuous measurement in the field. To overcome the difficulties, a second strategy was investigated: the cryogenic adsorption onto solid adsorbent followed by thermodesorption and a direct analysis by GC/MS. Collection efficiency using different solid adsorbents was found greater than 95% for carbonyl compounds consisting of 1 to 7 carbons. This work is a successful first step towards the realization of the automatic sampling device for a continuous measurement of atmospheric carbonyls compounds. (author)

  5. 30 CFR 57.19006 - Automatic hoist braking devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic hoist braking devices. 57.19006 Section 57.19006 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Hoisting Hoists § 57.19006 Automatic hoist braking devices. Automatic hoists shall be provided with devices...

  6. 30 CFR 56.19006 - Automatic hoist braking devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic hoist braking devices. 56.19006 Section 56.19006 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Hoisting Hoists § 56.19006 Automatic hoist braking devices. Automatic hoists shall be provided with devices...

  7. Inter-device reliability of an automatic-scoring actigraph for measuring sleep in healthy adults

    Directory of Open Access Journals (Sweden)

    Matthew Driller

    2016-07-01

    Full Text Available Actigraphy has become a common method of measuring sleep due to its non-invasive, cost-effective nature. An actigraph (Readiband™ that utilizes automatic scoring algorithms has been used in the research, but is yet to be evaluated for its inter-device reliability. A total of 77 nights of sleep data from 11 healthy adult participants was collected while participants were concomitantly wearing two Readiband™ actigraphs attached together (ACT1 and ACT2. Sleep indices including total sleep time (TST, sleep latency (SL, sleep efficiency (SE%, wake after sleep onset (WASO, total time in bed (TTB, wake episodes per night (WE, sleep onset variance (SOV and wake variance (WV were assessed between the two devices using mean differences, 95% levels of agreement, intraclass correlation coefficients (ICC, typical error of measurement (TEM and coefficient of variation (CV% analysis. There were no significant differences between devices for any of the measured sleep variables (p>0.05. TST, SE, SL, TTB, SOV and WV all resulted in very high ICC's (>0.90, with WASO and WE resulting in high ICC's between devices (0.85 and 0.80, respectively. Mean differences of −2.1 and 0.2 min for TST and SL were associated with a low TEM between devices (9.5 and 3.8 min, respectively. SE resulted in a 0.3% mean difference between devices. The Readiband™ is a reliable tool for researchers using multiple devices of this brand in sleep studies to assess basic measures of sleep quality and quantity in healthy adult populations.

  8. Automatic shadowing device for electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, F W; Bogitch, S

    1960-01-01

    For the past ten years in the laboratory of the Department of Nuclear Medicine and Radiation Biology at the University of California, and before that at Rochester, New York, every evaporation was done with the aid of an automatic shadowing device. For several months the automatic shadowing device has been available at the Atomic Bomb Casualty Commission (ABCC) Hiroshima, Japan with the modifications described. 1 reference.

  9. Automatic device for measuring β-emitting sources: P.A.P.A. β-meters

    International Nuclear Information System (INIS)

    Colomer, J.; Valentin, M.

    1969-01-01

    The apparatus described is designed for measuring β-emitting elements by the absorption method; it is suitable for carrying out a large number of routine analyses. A mechanical device pushes an aluminium absorption set automatically between the source and the detector; the movement is programmed for cutting on and off by a transistorized electronic unit, with printing out and punching of the results on tape; then this can be mathematically processed by a computer (tracing of absorption spectra, extrapolation and calculation of the activity). The detector is either a β-probe or a proportional counter with a specially designed loop. For routine measurements, the accuracy obtained, with all corrections made, is from 5 to 8 per cent; the reproducibility is about 2 per cent. (authors) [fr

  10. Automatic alignment device for focal spot measurements in the center of the field for mammography

    International Nuclear Information System (INIS)

    Vieira, Marcelo A.C.; Watanabe, Alex O.; Oliveira Junior, Paulo D.; Schiabel, Homero

    2010-01-01

    Some quality control procedures used for mammography, such as focal spot evaluation, requires previous alignment of the measurement equipment with the X-ray central beam. However, alignment procedures are, in general, the most difficult task and the one that needs more time to be performed. Moreover, the operator sometimes is exposed to radiation during this procedure. This work presents an automatic alignment system for mammographic equipment that allows locating the central ray of the radiation beam and, immediately, aligns with it by dislocating itself automatically along the field. The system consists on a bidirectional moving device, connected to a CCD sensor for digital radiographic image acquisition. A computational analysis of a radiographic image, acquired at any position on the field, is performed in order to determine its positioning under the X-ray beam. Finally, a mechanical system for two moving directions, electronically controlled by a microcontroller under USB communication, makes the system to align automatically with the radiation beam central ray. The alignment process is fully automatic, fast and accurate, with no operator exposure to radiation, which allows a considerable time saving for quality control procedures achievement for mammography. (author)

  11. 'Becquerel screening' device to automatically measure activity level of contaminated soil in flexible containers

    International Nuclear Information System (INIS)

    Okada, Hisashi; Yamaguchi, Yoshihisa; Yamamoto, Shuji

    2014-01-01

    Contaminated soil and incineration ash collected during offsite decontamination work following the accident at the Fukushima Daiichi Nuclear Power Station of Tokyo Electric Power Co., Inc. is being stored in flexible containers. These containers are managed taking their activity level into account in accordance with the Decontamination Guidelines issued by the Ministry of the Environment. Toshiba has developed the 'Becquerel Screening' device that can automatically measure the activity level of the contents of each flexible container simply by placing the container on a palette, without the need to take samples for analysis from the container. The Becquerel Screening device is expected to contribute not only to improved operational efficiency but also to reduced exposure of operators to radiation, because it eliminates the need for direct contact with contaminated soil and ash. (author)

  12. A Device for Automatically Measuring and Supervising the Critical Care Patient’S Urine Output

    Directory of Open Access Journals (Sweden)

    Roemi Fernández

    2010-01-01

    Full Text Available Critical care units are equipped with commercial monitoring devices capable of sensing patients’ physiological parameters and supervising the achievement of the established therapeutic goals. This avoids human errors in this task and considerably decreases the workload of the healthcare staff. However, at present there still is a very relevant physiological parameter that is measured and supervised manually by the critical care units’ healthcare staff: urine output. This paper presents a patent-pending device capable of automatically recording and supervising the urine output of a critical care patient. A high precision scale is used to measure the weight of a commercial urine meter. On the scale’s pan there is a support frame made up of Bosch profiles that isolates the scale from force transmission from the patient’s bed, and guarantees that the urine flows properly through the urine meter input tube. The scale’s readings are sent to a PC via Bluetooth where an application supervises the achievement of the therapeutic goals. The device is currently undergoing tests at a research unit associated with the University Hospital of Getafe in Spain.

  13. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  14. Automatic operation device for control rods

    International Nuclear Information System (INIS)

    Sekimizu, Koichi

    1984-01-01

    Purpose: To enable automatic operation of control rods based on the reactor operation planning, and particularly, to decrease the operator's load upon start up and shutdown of the reactor. Constitution: Operation plannings, demand for the automatic operation, break point setting value, power and reactor core flow rate change, demand for operation interrupt, demand for restart, demand for forecasting and the like are inputted to an input device, and an overall judging device performs a long-term forecast as far as the break point by a long-term forecasting device based on the operation plannings. The automatic reactor operation or the like is carried out based on the long-term forecasting and the short time forecasting is performed by the change in the reactor core status due to the control rod operation sequence based on the control rod pattern and the operation planning. Then, it is judged if the operation for the intended control rod is possible or not based on the result of the short time forecasting. (Aizawa, K.)

  15. Vibration analysis on automatic take-up device of belt conveyor

    Science.gov (United States)

    Qin, Tailong; Wei, Jin

    2008-10-01

    Through introducing application condition of belt conveyor in the modern mining industry, the paper proposed, in the dynamic course of its starting, braking or loading, it would produce moving tension and elastic wave. And analyzed the factors cause the automatic take-up device of belt conveyor vibrating: the take-up device's structure and the elastic wave. Finally the paper proposed the measure to reduce vibration and carried on the modeling and simulation on the tension buffer device.

  16. Device for the automatic evaluation of pencil dosimeters

    International Nuclear Information System (INIS)

    Schallopp, B.

    1976-01-01

    In connenction with the automation of radiation protection in nuclear power plants, an automatic reading device has been developed for the direct input of the readings of pencil dosimeters into a computer. Voltage measurements would be simple but are excluded, because the internal electrode of the dosimeter may not be touched, for operational reasons. This paper describes an optical/electronic conversion device in which the reading of the dosimeter is projected onto a Vidicon, scanned, and converted into a digital signal for output to the computer. (orig.) [de

  17. Automatic liquid nitrogen feeding device

    International Nuclear Information System (INIS)

    Gillardeau, J.; Bona, F.; Dejachy, G.

    1963-01-01

    An automatic liquid nitrogen feeding device has been developed (and used) in the framework of corrosion tests realized with constantly renewed uranium hexafluoride. The issue was to feed liquid nitrogen to a large capacity metallic trap in order to condensate uranium hexafluoride at the exit of the corrosion chambers. After having studied various available devices, a feeding device has been specifically designed to be robust, secure and autonomous, as well as ensuring a high liquid nitrogen flowrate and a highly elevated feeding frequency. The device, made of standard material, has been used during 4000 hours without any problem [fr

  18. 30 CFR 77.410 - Mobile equipment; automatic warning devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mobile equipment; automatic warning devices. 77... UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.410 Mobile equipment; automatic warning devices. (a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except...

  19. System for measurement and automatic regulation of gas flow within an oil aging test device

    Directory of Open Access Journals (Sweden)

    Žigić Aleksandar

    2014-01-01

    Full Text Available This paper describes a system within an oil aging test device that serves for measurement and automatic regulation of gas flow. Following an already realized system that continuously monitors, logs, and regulates transformer oil temperature during the aging process and maintains temperature consistency within strict limits, a model of a flow meter and regulator of air or oxygen through transformer oil samples is developed. A special feature of the implemented system is the measurement of very small gas flows. A short technical description of the realized system is given with a functional block diagram. The basic technical characteristics of the system are specified, and the operating principles and application of the system are described. The paper also gives performance test results in a real exploitation environment.

  20. The use of a new automatic device for patients' assessment at Triage in Emergency Department

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2013-06-01

    Full Text Available Objectives: To assess time saving in an Emergency Department arising out of the introduction of automatic devices (Carescape™ V100 to measure vital signs compared to the manual devices. Methods: We performed a prospective, observational study of eligible patients referring to Sant’Andrea Hospital Emergency Department during the entire month of October 2009, randomly assigned into two groups. In the first group of 476 patients vital signs measurements were detected with manual devices, while in the second group of 477 patients with automatic device Carescape™ V100. Results: Data indicated that the comparison of the total time between the two groups gave a significant difference (1993 vs 1518 min, p < 0.001. No differences were found with respect to age, sex and priority codes. Significant differences were also found when comparing the subgroups of the same acuity categories: white codes 4.33 vs 2.27 (min, p < 0.05; green codes 4.28 vs 3.37 (min, p < 0.001; yellow codes 3.92 vs 2.72 (min, p < 0.001. Conclusions: Our data demonstrated a statistical significance between the two groups with a difference of 475 minutes spent in Triage procedures including vital signs measurements. In conclusion time saved by vital signs automatic device could allow ED physicians to make a qualified approach with an earlier diagnosis and a more rapid and effective therapy, possibly improving patients’ outcomes. ABSTRACT of data concerning vital signs quality assessment, because we did not compare the two methods in the same patient and we did not correlate Triage priority evaluation with patients’ outcomes. In the future further studies should be specifically aimed to address this issue. In conclusion time saved by vital signs automatic device could allow ED physicians to make a qualified approach to patient with an earlier diagnosis and a more rapid and effective therapy, possibly improving patients’ outcomes.

  1. Automatic Measurement of Low Level Contamination on Concrete Surfaces

    International Nuclear Information System (INIS)

    Tachibana, M.; Itoh, H.; Shimada, T.; Yanagihara, S.

    2002-01-01

    Automatic measurement of radioactivity is necessary for considering cost effectiveness in final radiological survey of building structures in decommissioning nuclear facilities. The RAPID (radiation measuring pilot device for surface contamination) was developed to be applied to automatic measurement of low level contamination on concrete surfaces. The RAPID has a capability to measure contamination with detection limit of 0.14 Bq/cm2 for 60Co in 30 seconds of measurement time and its efficiency is evaluated to be 5 m2/h in a normal measurement option. It was confirmed that low level contamination on concrete surfaces could be surveyed by the RAPID efficiently compared with direct measurement by workers through its actual application

  2. Device for the nuclear reactor automatic start-up and power control

    International Nuclear Information System (INIS)

    Nikiforov, B.N.; Volkov, A.V.; Ogon'kov, A.I.

    1978-01-01

    A description and flowsheet of a reactor start-up and power-control automatic device containing no nonlinear elements with a relay characteristic are presented. The device consists of two independent channels for measuring the physical power and time (period) constant of the reactor. Requirements for the device are considered, based on the condition of a minimum permissible number of a servomechanism operations due to fluctuations of an input signal which appear because of the statistical nature of processes taking place in the reactor. It is noted that the threshold amplifier used in the device allows a considerable decrease of the reactor start-up time

  3. Poster Abstract: Automatic Calibration of Device Attitude in Inertial Measurement Unit Based Traffic Probe Vehicles

    KAUST Repository

    Mousa, Mustafa

    2016-04-28

    Probe vehicles consist in mobile traffic sensor networks that evolve with the flow of vehicles, transmitting velocity and position measurements along their path, generated using GPSs. To address the urban positioning issues of GPSs, we propose to replace them with inertial measurement units onboard vehicles, to estimate vehicle location and attitude using inertial data only. While promising, this technology requires one to carefully calibrate the orientation of the device inside the vehicle to be able to process the acceleration and rate gyro data. In this article, we propose a scheme that can perform this calibration automatically by leveraging the kinematic constraints of ground vehicles, and that can be implemented on low-end computational platforms. Preliminary testing shows that the proposed scheme enables one to accurately estimate the actual accelerations and rotation rates in the vehicle coordinates. © 2016 IEEE.

  4. A simple method for automatic measurement of excitation functions

    International Nuclear Information System (INIS)

    Ogawa, M.; Adachi, M.; Arai, E.

    1975-01-01

    An apparatus has been constructed to perform the sequence control of a beam-analysing magnet for automatic excitation function measurements. This device is also applied to the feedback control of the magnet to lock the beam energy. (Auth.)

  5. Study of an automatized experimental device for the irradiation of a radioactive target

    International Nuclear Information System (INIS)

    Claverie, G.

    1996-01-01

    In order to solve the enigma of solar neutrinos, a team of physicians of the nuclear research center of Bordeaux-Gradignan and of the center of nuclear spectroscopy and mass spectroscopy of Orsay (France) decided to measure again the cross section of the beryllium-proton nuclear reaction at the lowest possible energies. This measurement requires the design of an automatized experimental device to irradiate in a specific way a beryllium target with an accelerated proton beam. The aim of this work is the study of such a device for an energy range of 800 to 300 KeV. This device comprises a particle multi-detector and a shutter for the irradiation of the target and the counting of the reaction products according to a programmable time sequence. The advantage of this setup is to allow an important bombardment of the target and to ensure its cooling. This device is automatically controlled thanks to a micro-controller, actuators (step motors and electrostatic deflector). It includes some beam diagnosis elements controlled by step motors and a target temperature monitoring system controlling a safety valve. The management of the experiment cell vacuum has led to the design of a vacuum monitor allowing the precise follow up of the vacuum and the control of the safety valves of the device. The nuclear instrumentation necessary to be implemented for this measurement is also presented. (J.S.)

  6. Manual versus automatic bladder wall thickness measurements: a method comparison study

    NARCIS (Netherlands)

    Oelke, M.; Mamoulakis, C.; Ubbink, D.T.; de la Rosette, J.J.; Wijkstra, H.

    2009-01-01

    Purpose To compare repeatability and agreement of conventional ultrasound bladder wall thickness (BWT) measurements with automatically obtained BWT measurements by the BVM 6500 device. Methods Adult patients with lower urinary tract symptoms, urinary incontinence, or postvoid residual urine were

  7. Automatic Number Plate Recognition System for IPhone Devices

    Directory of Open Access Journals (Sweden)

    Călin Enăchescu

    2013-06-01

    Full Text Available This paper presents a system for automatic number plate recognition, implemented for devices running the iOS operating system. The methods used for number plate recognition are based on existing methods, but optimized for devices with low hardware resources. To solve the task of automatic number plate recognition we have divided it into the following subtasks: image acquisition, localization of the number plate position on the image and character detection. The first subtask is performed by the camera of an iPhone, the second one is done using image pre-processing methods and template matching. For the character recognition we are using a feed-forward artificial neural network. Each of these methods is presented along with its results.

  8. Device for radioactivity measurement of liquid samples

    International Nuclear Information System (INIS)

    Lamaziere, J.

    1983-01-01

    The device for low activity gamma measurements comprises an automatic changer for sample transfer from a conveyor to a measuring chamber. The conveyor includes a horizontal table were are regularly distributed sample holders. A lift allows a vertical motion of a plate for the exposition in front of a detector [fr

  9. Design of automatic control and measurement software for radioactive aerosol continuity monitor

    International Nuclear Information System (INIS)

    Mao Yong; Li Aiwu

    1997-01-01

    The radioactive aerosol continuity measurement is very important for the development of nuclear industry, and it is the major method to measure and find out the leakage of radioactive material. Radioactive aerosol continuity monitor is the advanced method for the radioactive aerosol continuity measurement. With the development of nuclear industry and nuclear power station, it is necessary to design and automatic continuity measurement device. Because of this reason, the authors developed the first unit of radioactive aerosol continuity monitor and adopted the ministry appraisal. The design idea and method of automatic control and measurement for radioactive aerosol continuity monitor are discussed

  10. Nuclear-burst strength detecting and measuring device

    International Nuclear Information System (INIS)

    Balut, J.A.L.G.; Lemaire, P.E.G.K.; Loisy, C.M.

    1976-01-01

    A continuous-operation automatic device is described for detection and accurate measurement of the strength of a burst generating an emission from luminous or infrared sources. This device characterizes and analyzes the maxima and minima of a ''thermal flux/time'' curve. The device comprises a master time element and an assembly of photoelectric detectors, an electronic processing system coupled to the detectors, and a mechanical system securing the rigidity and positioning of the photoelectric detector assembly with respect to an octahedral prism based on a horizontal plane

  11. Norms concerning the programmable automatic control devices

    International Nuclear Information System (INIS)

    Fourmentraux, G.

    1995-01-01

    This presentation is a report of the studies carried out by the Work Group on Functioning Safety of Programmable Automatic Control Devices and by the Group for Prevention Studies (GEP) from the CEA. The objective of these groups is to evaluate the methods which could be used to estimate the functioning safety of control and instrumentation systems involved in the Important Elements for Safety (EIS) of the Basic Nuclear Installations (INB) of the CEA, and also to carry out a qualification of automatic control devices. Norms, protocols and tools for the evaluation are presented. The problem comprises two aspects: the evaluation of fault avoidance techniques and the evaluation of fault control techniques used during the conceiving. For the fault avoidance techniques, the quality assurance organization, the environment tests, and the software quality plans are considered. For the fault control techniques, the different available tools and fault injection models are analysed. The results of an analysis carried out with the DEF.I tool from the National Institute for Research and Safety (INRS) are reported. (J.S.). 23 refs

  12. A device for automatically recording information on the reasons for idling of stopes

    Energy Technology Data Exchange (ETDEWEB)

    Dergachev, L G; Kuzoyatov, G I; Tereshchenko, V N

    1979-01-01

    One substantial reserve for raising production efficiency in the coal industry is reduction of nonproductive time costs. The state of the art of stoping work and design features of stoping equipment and devices for obtaining information do not presently enable complete automation of the process of obtaining data on the reasons for down times. Therefore, together with automatic data formation manual recording of information is required through remote control equipment to the controlling computer directly from the work place. The Donetsk department of the Giprougleavtomatizatsiy institute has developed the UKIP-1 device for automatic recording of information on the reasons for stope down times. The device is designed for use in an automatic process control system of coal mines. It provides coding of information and its conversion to a form suitable for transmission through remote control channels, further processing, and recording. The device enables recording of information on down times of eight objects of the stope. Up to eight down time reasons can be recorded for each object. The device has 2 contact outputs, on one of which is formed an informational sequential eight-bit code; on the other, 8 clock pulses. The device's code is generated automatically, after it is activated by a switch. The length of the code packet results from the maximum possible information transmission rate of the existing mine remote control systems, and equals 12+2 sec. The clock pulse length equals half the length of the information pulse. The device has been tested at coal mines, and recommended for industrial production. UKIP-1 devices are being used in a pilot model of an automatic production control system of the Sotsialisticheskiy Donbass Newspaper mine of the Donetskugol' production association.

  13. Device for positioning and generation of an element of track model and slice of the MELAS automatic equipment

    International Nuclear Information System (INIS)

    Kryutchenko, E.V.; Fedotov, V.S.

    1979-01-01

    The structure and organization of the device for positioning and generation of element of track model and slice of the MELAS automatic equipment which is developed for measuring films from big bubble chambers, is described. Main features of the device are studied and characteristics are given as well

  14. An automatic device for charging a storage battery

    Energy Technology Data Exchange (ETDEWEB)

    Pasyukov, A A

    1984-01-01

    The purpose of the invention is to increase the service life of storage batteries (AB) through ensuring automatic protection of the device from overloads with short circuits (KZ) and from incorrect switching polarity of the storage batteries. The device contains a transformer, a rectifier, a smoothing capacitor, a trigger capacitor, a charge current control transistor, a controllable transistor, a shielding transistor, two resistors, a diode, a resistor and a voltage divider, another resistor, a reference voltage stabilitron, a resistor and another diode and the storage battery.

  15. Automatic adjustment of bias current for direct current superconducting quantum interference device

    International Nuclear Information System (INIS)

    Makie-Fukuda, K.; Hotta, M.; Okajima, K.; Kado, H.

    1993-01-01

    A new method of adjusting the bias current of dc superconducting quantum interference device (SQUID) is described. It is shown that the signal-to-noise ratio of a SQUID magnetometer connected in a flux-locked loop configuration is proportional to the second harmonic of the output signal from the SQUID. A circuit configuration that can automatically optimize a SQUID's bias current by measuring this second harmonic and adjusting the bias current accordingly is proposed

  16. New devices for radon measurements

    International Nuclear Information System (INIS)

    Sevostyanov, V.N.

    2004-01-01

    This work includes the description of two new devices for radon surveys developed by the authors and produced in Kazakhstan. The first appliance is 'Ramon-Radon-01' used to measure 222 Rn radon in various mediums such as air, water, soil, and radon exhalation. The major advantage of the appliance lies in the absence of radioactive pollution in it after measurements. The appliances widely used in the CIS such as 'RAA-01', 'Alpharad' (produced by 'MTM Zaschita', Russia) and 'Alphaguard' (Germany) take samples directly to the measuring camera. For instance, the activity concentration of samples after they are taken by 'RAA-01' and 'Alpharad' is measured by means of electrostatic precipitation of RaA ( 218 Po) atoms to the square of semiconductor detector with subsequent registration of RaA alpha decay. The obvious disadvantage is that the subsequent measurement of relatively small 222 Rn activity concentration values after great values of 222 Rn activity concentration have been obtained requires a considerable exposure of the appliance sometimes exceeding 10 hours. Therefore, appliances register a relatively low value of the top measurement range of 20 KBq/m 3 . 'Alphaguard' has similar limitation resulting from precipitation of radon daughter decay products on the walls of ionizing chamber where radon activity concentration is measured. The radioactive lag of 'RAA-01', 'Alpharad' and 'Alphaguard' makes them of little use as well for automatic monitoring in the conditions of abruptly time negative derivatives on change of radon activity concentration. The second advantage is that 'Ramon-Radon-01', as opposed to above described appliances, registers almost zero radioactive lag, thanks to its constructive peculiarities which enable an abrupt increase of top range of measured value up to 5x10 5 Bq/m 3 , only limited by velocity of electron units of the appliance. The third advantage is that measurement discontinuity is determined only by time of full measurement cycle

  17. Dynamic pipe control with a multiple digit automatic measuring device

    International Nuclear Information System (INIS)

    Jenzer, P.

    1984-01-01

    With the flow rotating method, thin-walled pipes can be produced with very tight tolerances and high mechanical sturdiness. The measuring device permits a dynamic control of these pipes, the outer diameter of which can lie between 70 and 300 mm, the length between 500 and 2000 mm and the wall thickness between 0,5 and 10 mm. Depending on the pipe type, up to 27 measurements in a maximum of 5 measuring levels are to be controlled. (orig.) [de

  18. An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia

    Science.gov (United States)

    El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.

    2015-01-01

    We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532

  19. Opto-mechanical devices for the Antares automatic beam alignment system

    International Nuclear Information System (INIS)

    Swann, T.; Combs, C.; Witt, J.

    1981-01-01

    Antares is a 24-beam CO 2 laser system for controlled fusion research, under construction at Los Alamos National Laboratory. Rapid automatic alignment of this system is required prior to each experimental shot. Unique opto-mechanical alignment devices, which have been developed specifically for this automatic alignment system, are discussed. A variable focus alignment telescope views point light sources. A beam expander/spatial filter processes both a visible Krypton Ion and a 10.6 μm CO 2 alignment laser. The periscope/carousel device provides the means by which the alignment telescope can sequentially view each of twelve optical trains in each power amplifier. The polyhedron alignment device projects a point-light source for both centering and pointing alignment at the polyhedron mirror. The rotating wedge alignment device provides a sequencing point-light source and also compensates for dispersion between visible and 10.6 μm radiation. The back reflector flip in remotely positions point-light sources at the back reflector mirrors. A light source box illuminates optic fibers with high intensity white light which is distributed to the various point-light sources in the system

  20. Automatic dosimeter for kerma measurement based on commercial PIN photo diodes

    International Nuclear Information System (INIS)

    Kushpil, V.; Kushpil, S.; Huna, Z.

    2011-01-01

    A new automatic dosimeter for measurement of radiation dose from neutron and ionization radiation is presented. The dosimeter (kerma meter) uses commercial PIN diodes with long base as its active element. Later it provides a maximal dependence of the minority carriers life time versus absorbed dose. The characteristics of the dosimeter were measured for several types of commercial diodes. Device can be useful in many environmental or industrial applications. (authors)

  1. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  2. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  3. Determination of polycyclic aromatic compounds. Part project 11: Practice-oriented adaption and field testing of various automatic measuring devices; Messung polycyclischer aromatischer Verbindungen. Teilvorhaben 11: Praxisbezogene Anpassung und Felderprobung verschiedener automatischer Messeinrichtungen

    Energy Technology Data Exchange (ETDEWEB)

    Wilbring, P.; Jockel, W.

    1997-05-01

    The purpose of the present study was to examine various automatic emission measuring devices. The task was to determine polycyclic aromatic hydrocarbons (PAH) on-line. The following measuring devices were used: photoelectric aerosol sensor; emission mass spectrometer; laser-induced aerosol fluorescence; chemical ionisation mass spectrometer; photoelectric aerosol sensor. Most of the above-named measuring devices for automatic PAH monitoring had already demonstrated their general suitability in the course of extensive studies carried out in precursor projects. The next step, performed in this study, was to test the measuring devices` fitness for use. First, practice-oriented laboratory tests were carried out on the devices, whose measuring principles are incidentally highly diverse. These tests focussed on the identification of process parameters (e.g., detection limit, cross-sensitivity, availability, drift behaviour) and examination of the devices` analysis function and hence of their calibratability. (orig./SR) [Deutsch] In diesem Vorhaben wurden verschiedene automatisch arbeitende Emissionsmesseinrichtungen untersucht. Die Aufgabenstellung bestand in der on-line-Bestimmung von polycyclischen aromatischen Kohlenwasserstoffen (PAK). Dazu standen folgende Messeinrichtungen zur Verfuegung: - Photoelektrischer Aerosolsensor - Emissionsmassenspektrometer - Laserinduzierte Aerosolfluoreszenz - Chemisches Ionisationsmassenspektrometer - Photoelektrischer Aerosolsensor. Aus den umfangreichen Untersuchungen im Rahmen der Vorlaeuferprojekte ist die prinzipielle Einsatzfaehigkeit der meisten der oben genannten Messeinrichtungen zur automatisierbaren PAK-Kontrolle bekannt. Ziel des Vorhabens war es, die Praxistauglichkeit dieser auf den unterschiedlichsten Messprinzipien basierenden Messeinrichtungen zu untersuchen. Dazu waren zunaechst Labortests vorzunehmen. Diese Pruefungen erfolgen praxisorientert mit den Schwerpunkten: - Ermittlung von Verfahrenskenngroessen (z. B

  4. Device for measuring atmospheric radon activity

    International Nuclear Information System (INIS)

    Deml, F.; Jansky, Z.; Smejkal, Z.

    1989-01-01

    The device consists of a lightproof case pivoted on a stand. Minimally two chambers are provided in the case for holding glass scintillation chambers, each with an opening in its bottom. The centers of the openings lie on a common circle with its center in the center of rotation of the case. An opening for the passage of light is provided in the stand. The opening also is on the common circle of the centres of the openings. A photomultiplier is placed below the opening. Measurement always proceeds with one scintillation chamber only. Thus, replacement of scintillation chambers can take place simultaneously with measurement and rapid and continuous measurement can be secured. Case rotation can be controlled automatically. The device can be used not only in monitoring air pollution but also in monitoring solid materials, aquifers, mine corridors, natural materials, etc. (J.B.). 1 fig

  5. Automatic analysis of image quality control for Image Guided Radiation Therapy (IGRT) devices in external radiotherapy

    International Nuclear Information System (INIS)

    Torfeh, Tarraf

    2009-01-01

    On-board imagers mounted on a radiotherapy treatment machine are very effective devices that improve the geometric accuracy of radiation delivery. However, a precise and regular quality control program is required in order to achieve this objective. Our purpose consisted of developing software tools dedicated to an automatic image quality control of IGRT devices used in external radiotherapy: 2D-MV mode for measuring patient position during the treatment using high energy images, 2D-kV mode (low energy images) and 3D Cone Beam Computed Tomography (CBCT) MV or kV mode, used for patient positioning before treatment. Automated analysis of the Winston and Lutz test was also proposed. This test is used for the evaluation of the mechanical aspects of treatment machines on which additional constraints are carried out due to the on-board imagers additional weights. Finally, a technique of generating digital phantoms in order to assess the performance of the proposed software tools is described. Software tools dedicated to an automatic quality control of IGRT devices allow reducing by a factor of 100 the time spent by the medical physics team to analyze the results of controls while improving their accuracy by using objective and reproducible analysis and offering traceability through generating automatic monitoring reports and statistical studies. (author) [fr

  6. Technical note: Quantifying and characterizing behavior in dairy calves using the IceTag automatic recording device

    DEFF Research Database (Denmark)

    Trénel, P.; Jensen, Margit Bak; Decker, Erik Luc

    2009-01-01

    The objectives of the current study were 1) to validate the IceTag ( http://www.icerobotics.com/ ) automatic recording device for measuring lying, standing, and moving behavior in dairy calves, and 2) to improve the information yield from this device by applying a filtering procedure allowing...... for the detection of lying versus upright. The IceTag device provides measures of intensity (I) of lying, standing, and activity measured as percent lying, percent standing, and percent active, but does not directly measure lying, standing, and moving behavior because body movements occurring while lying (e...... (LPC) was established empirically, and IceTag data were filtered according to the LPC, providing information on the posture of the animal as lying versus being upright. Third, a new threshold of I was estimated for moving activity conditional on the animal being upright. IceTag recordings from 9 calves...

  7. Automatic Data Logging and Quality Analysis System for Mobile Devices

    Directory of Open Access Journals (Sweden)

    Yong-Yi Fanjiang

    2017-01-01

    Full Text Available The testing phase of mobile device products includes two important test projects that must be completed before shipment: the field trial and the beta user trial. During the field trial, the product is certified based on its integration and stability with the local operator’s system, and, during the beta user trial, the product is certified by multiple users regarding its daily use, where the goal is to detect and solve early problems. In the traditional approach used to issue returns, testers must log into a web site, fill out a problem form, and then go through a browser or FTP to upload logs; however, this is inconvenient, and problems are reported slowly. Therefore, we propose an “automatic logging analysis system” (ALAS to construct a convenient test environment and, using a record analysis (log parser program, automate the parsing of log files and have questions automatically sent to the database by the system. Finally, the mean time between failures (MTBF is used to establish measurement indicators for the beta user trial.

  8. CURRENT STATE ANALYSIS OF AUTOMATIC BLOCK SYSTEM DEVICES, METHODS OF ITS SERVICE AND MONITORING

    Directory of Open Access Journals (Sweden)

    A. M. Beznarytnyy

    2014-01-01

    Full Text Available Purpose. Development of formalized description of automatic block system of numerical code based on the analysis of characteristic failures of automatic block system and procedure of its maintenance. Methodology. For this research a theoretical and analytical methods have been used. Findings. Typical failures of the automatic block systems were analyzed, as well as basic reasons of failure occur were found out. It was determined that majority of failures occurs due to defects of the maintenance system. Advantages and disadvantages of the current service technology of automatic block system were analyzed. Works that can be automatized by means of technical diagnostics were found out. Formal description of the numerical code of automatic block system as a graph in the state space of the system was carried out. Originality. The state graph of the numerical code of automatic block system that takes into account gradual transition from the serviceable condition to the loss of efficiency was offered. That allows selecting diagnostic information according to attributes and increasing the effectiveness of recovery operations in the case of a malfunction. Practical value. The obtained results of analysis and proposed the state graph can be used as the basis for the development of new means of diagnosing devices for automatic block system, which in turn will improve the efficiency and service of automatic block system devices in general.

  9. Automatic measurement of images on astrometric plates

    Science.gov (United States)

    Ortiz Gil, A.; Lopez Garcia, A.; Martinez Gonzalez, J. M.; Yershov, V.

    1994-04-01

    We present some results on the process of automatic detection and measurement of objects in overlapped fields of astrometric plates. The main steps of our algorithm are the following: determination of the Scale and Tilt between charge coupled devices (CCD) and microscope coordinate systems and estimation of signal-to-noise ratio in each field;--image identification and improvement of its position and size;--image final centering;--image selection and storage. Several parameters allow the use of variable criteria for image identification, characterization and selection. Problems related with faint images and crowded fields will be approached by special techniques (morphological filters, histogram properties and fitting models).

  10. A device for automatic photoelectric control of the analytical gap for emission spectrographs

    Science.gov (United States)

    Dietrich, John A.; Cooley, Elmo F.; Curry, Kenneth J.

    1977-01-01

    A photoelectric device has been built that automatically controls the analytical gap between electrodes during excitation period. The control device allows for precise control of the analytical gap during the arcing process of samples, resulting in better precision of analysis.

  11. Process and device for automatically surveying complex installations

    International Nuclear Information System (INIS)

    Pekrul, P.J.; Thiele, A.W.

    1976-01-01

    A description is given of a process for automatically analysing separate signal processing channels in real time, one channel per signal, in a facility with significant background noise in signals varying in time and coming from transducers at selected points for the continuous monitoring of the operating conditions of the various components of the installation. The signals are intended to determine potential breakdowns, determine conclusions as to the severity of these potential breakdowns and indicate to an operator the measures to be taken in consequence. The feature of this process is that it comprises the automatic and successive selection of each channel for the purpose of spectral analysis, the automatic processing of the signal of each selected channel to show energy spectrum density data at pre-determined frequencies, the automatic comparison of the energy spectrum density data of each channel with pre-determined sets of limits varying with the frequency, and the automatic indication to the operator of the condition of the various components of the installation associated to each channel and the measures to be taken depending on the set of limits [fr

  12. A comparison of 'radon' measurement devices

    International Nuclear Information System (INIS)

    Rolle, R.

    2004-01-01

    For the indoor concentration measurement of Rn decay chain members, instruments ranging from long-term integrating passive devices to far more sensitive active devices with good time resolution are in use. The former are used mainly to screen for potentially high exposure locations, while the latter are useful for assessing the exposure dynamics of encumbered premises, with potential clarification (modelling) for optimal remediation, before, during and after such process. Concentration measurement of any one decay chain member always involves its complete decay chain. The 222 Rn gas concentration can be measured with gas measuring devices or with spectrometric measuring instruments that concentrate the decay products. The latter generally offer far more accurate measurement per time of the 222 Rn concentration, than mere Rn gas measuring devices, and also give the decay product concentrations and thus activity ratios which are related to air exchange. The concentrations of the unattached Rn decay products may be measured simultaneously with inline screen measurement. In premises steady state ventilation conditions are rare. Rapidly changing concentrations can be measured more accurately with the more sensitive concentrating instruments - the inherent instrumental time lag of detected signals from chain decay, relative to time of sampling, should however be corrected where rates of concentration change approximate chain decay constants. Counting of beta-signals in addition to alpha-spectrometry, and quasi-continuous sampling while continuously measuring, enhances the sensitivity, and particularly measurement time lag correction, where concentration ratios are sought for elucidating air exchange. Appropriate software ought to be made available to evaluate the spectrometric data and to link it to suitable compartment ventilation models (automatic adjustment for a dynamic change in alpha-calibration could be incorporated) - this would constitute the modern version of

  13. Design of the device of auto-measuring radon continuously based on FPGA

    International Nuclear Information System (INIS)

    Wang Yan; Shen Zhengqin; Chen Qiong

    2004-01-01

    This paper introduces the design of the device of auto-measuring radon continuously. The core of the system is the design of controlling system by FPGA, which consists of preset module, electrical calendar module and driving module. The system can automatically measure the consistence of the radon and the separating out rate of it. The information data is displayed by LCD. The high speed micro printer is used to print the measuring result. It adopts FPGA to design the measuring system of the device, which can improve the precision and stability of the system. (authors)

  14. Automatic positioning control device for automatic control rod exchanger

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To attain accurate positioning for a control rod exchanger. Constitution: The present position for an automatic control rod exchanger is detected by a synchro generator. An aimed stopping position for the exchanger, a stop instruction range depending on the distantial operation delay in the control system and the inertia-running distance of the mechanical system, and a coincidence confirmation range depending on the required positioning accuracy are previously set. If there is a difference between the present position and the aimed stopping position, the automatic exchanger is caused to run toward the aimed stopping position. A stop instruction is generated upon arrival at the position within said stop instruction range, and a coincidence confirmation signal is generated upon arrival at the position within the coincidence confirmation range. Since uncertain factors such as operation delay in the control system and the inertia-running distance of the mechanical system that influence the positioning accuracy are made definite by the method of actual measurement or the like and the stop instruction range and the coincidence confirmation range are set based on the measured data, the accuracy for the positioning can be improved. (Ikeda, J.)

  15. Automatic limit switch system for scintillation device and method of operation

    International Nuclear Information System (INIS)

    Brunnett, C.J.; Ioannou, B.N.

    1976-01-01

    A scintillation scanner is described having an automatic limit switch system for setting the limits of travel of the radiation detection device which is carried by a scanning boom. The automatic limit switch system incorporates position responsive circuitry for developing a signal representative of the position of the boom, reference signal circuitry for developing a signal representative of a selected limit of travel of the boom, and comparator circuitry for comparng these signals in order to control the operation of a boom drive and indexing mechanism. (author)

  16. The ''controbloc'', a programmable automatic device for the 1,300 MW generation of power stations

    International Nuclear Information System (INIS)

    Pralus, B.; Winzelle, J.C.

    1983-01-01

    Technological progress in the field of microelectronics has led to the development of an automatic control device, the ''controbloc'', for operating and controlling nuclear power plants. The ''controbloc'' will be used in automatic systems with a high degree of safety and versatility and is now being installed in the first of the new generation 1,300 MW power stations. The main characteristics of the device and the evaluation tests which have been carried out are described [fr

  17. Development of on line automatic separation device for apple and sleeve

    Science.gov (United States)

    Xin, Dengke; Ning, Duo; Wang, Kangle; Han, Yuhang

    2018-04-01

    Based on STM32F407 single chip microcomputer as control core, automatic separation device of fruit sleeve is designed. This design consists of hardware and software. In hardware, it includes mechanical tooth separator and three degree of freedom manipulator, as well as industrial control computer, image data acquisition card, end effector and other structures. The software system is based on Visual C++ development environment, to achieve localization and recognition of fruit sleeve with the technology of image processing and machine vision, drive manipulator of foam net sets of capture, transfer, the designated position task. Test shows: The automatic separation device of the fruit sleeve has the advantages of quick response speed and high separation success rate, and can realize separation of the apple and plastic foam sleeve, and lays the foundation for further studying and realizing the application of the enterprise production line.

  18. Automatic measurement for solid state track detectors

    International Nuclear Information System (INIS)

    Ogura, Koichi

    1982-01-01

    Since in solid state track detectors, their tracks are measured with a microscope, observers are forced to do hard works that consume time and labour. This causes to obtain poor statistic accuracy or to produce personal error. Therefore, many researches have been done to aim at simplifying and automating track measurement. There are two categories in automating the measurement: simple counting of the number of tracks and the requirements to know geometrical elements such as the size of tracks or their coordinates as well as the number of tracks. The former is called automatic counting and the latter automatic analysis. The method to generally evaluate the number of tracks in automatic counting is the estimation of the total number of tracks in the total detector area or in a field of view of a microscope. It is suitable for counting when the track density is higher. The method to count tracks one by one includes the spark counting and the scanning microdensitometer. Automatic analysis includes video image analysis in which the high quality images obtained with a high resolution video camera are processed with a micro-computer, and the tracks are automatically recognized and measured by feature extraction. This method is described in detail. In many kinds of automatic measurements reported so far, frequently used ones are ''spark counting'' and ''video image analysis''. (Wakatsuki, Y.)

  19. Automatic Time Regulator for Switching on an Aeration Device for ...

    African Journals Online (AJOL)

    The need to aerate the pond at odd hours due to diurnal limit, save cost and human labor, necessitated the design of an automatic time regulator circuit, which controls the switching on and o of an aeration device at a pre determined and selected time interval (5mins., 10mins., 20mins., 30mins., and 40mins.) This design ...

  20. Automatic locking orthotic knee device

    Science.gov (United States)

    Weddendorf, Bruce C. (Inventor)

    1993-01-01

    An articulated tang in clevis joint for incorporation in newly manufactured conventional strap-on orthotic knee devices or for replacing such joints in conventional strap-on orthotic knee devices is discussed. The instant tang in clevis joint allows the user the freedom to extend and bend the knee normally when no load (weight) is applied to the knee and to automatically lock the knee when the user transfers weight to the knee, thus preventing a damaged knee from bending uncontrollably when weight is applied to the knee. The tang in clevis joint of the present invention includes first and second clevis plates, a tang assembly and a spacer plate secured between the clevis plates. Each clevis plate includes a bevelled serrated upper section. A bevelled shoe is secured to the tank in close proximity to the bevelled serrated upper section of the clevis plates. A coiled spring mounted within an oblong bore of the tang normally urges the shoes secured to the tang out of engagement with the serrated upper section of each clevic plate to allow rotation of the tang relative to the clevis plate. When weight is applied to the joint, the load compresses the coiled spring, the serrations on each clevis plate dig into the bevelled shoes secured to the tang to prevent relative movement between the tang and clevis plates. A shoulder is provided on the tang and the spacer plate to prevent overextension of the joint.

  1. Automatic illumination compensation device based on a photoelectrochemical biofuel cell driven by visible light

    Science.gov (United States)

    Yu, You; Han, Yanchao; Xu, Miao; Zhang, Lingling; Dong, Shaojun

    2016-04-01

    Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications.Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00759g

  2. TAPIR: a device for automatic titration with incremental weighing of the titration reagent

    International Nuclear Information System (INIS)

    Ganivet, Michel

    TAPIR is a titration device enabling automatic analyses with weighting of the titration reagent. The titration method used can be based on potentiometry, amperometry, color indicator change... The reproducibility is about 3.10 -4 [fr

  3. Automatic scanning and measuring using POLLY

    International Nuclear Information System (INIS)

    Fields, T.

    1993-01-01

    The HPD and PEPR automatic measuring systems, which have been described by B. Powell and I. Pless at this conference, were developed in the 1960's to be used for what would now be called open-quotes batch processing.close quotes That is, an entire reel of bubble chamber film containing interesting events whose tracks had been rough-digitized would be processed in an extended run by a dedicated computer/precision digitizer hardware system, with no human intervention. Then, at a later time, events for which the precision measurement did not appear to be successful would be handled with some type of open-quotes fixupclose quotes station or process. By contrast, the POLLY system included from the start, not only a computer and a precision CRT measuring device, but also a human operator who could have convenient two-way interactions with the computer and could also view the picture directly. Inclusion of a human as a key part of the system had some important beneficial effects, as has been described in the original papers. In this note the author summarizes those effects, and also points out connections between the POLLY system philosophy and subsequent developments in both high energy physics data analysis and computing systems

  4. Automatic control and detector for three-terminal resistance measurement

    Science.gov (United States)

    Fasching, George E.

    1976-10-26

    A device is provided for automatic control and detection in a three-terminal resistance measuring instrument. The invention is useful for the rapid measurement of the resistivity of various bulk material with a three-terminal electrode system. The device maintains the current through the sample at a fixed level while measuring the voltage across the sample to detect the sample resistance. The three-electrode system contacts the bulk material and the current through the sample is held constant by means of a control circuit connected to a first of the three electrodes and works in conjunction with a feedback controlled amplifier to null the voltage between the first electrode and a second electrode connected to the controlled amplifier output. An A.C. oscillator provides a source of sinusoidal reference voltage of the frequency at which the measurement is to be executed. Synchronous reference pulses for synchronous detectors in the control circuit and an output detector circuit are provided by a synchronous pulse generator. The output of the controlled amplifier circuit is sampled by an output detector circuit to develop at an output terminal thereof a D.C. voltage which is proportional to the sample resistance R. The sample resistance is that segment of the sample between the area of the first electrode and the third electrode, which is connected to ground potential.

  5. Device for correction of the spot dimensions and its form in the measuring CRT of the MELAS automatic unit

    International Nuclear Information System (INIS)

    Kachnova, O.A.; Kryutchenko, E.V.; Utochkin, B.A.; Fedotov, V.S.

    1979-01-01

    A digital-to-analog converter is described, designed for dynamic correction of beam focusing of the measuring cathode-ray tube (CRT) of the MELAS automatic device. The described converter consists of two identical units. Every unit generates a voltage proportional to square of deviations along the X and Y axes. Output voltages of both channels are summarized by an analog adder, transformed into current and are fed to the focusing system. The computer circuit used to correct the dimensions of the CRT beam uses microcircuits with low and medium levels of integration and has the following characteristics: the maximum correcting current is 12.4 mA, the direct component of the focusing current is 0.24 A, the correcting current instability is 0.08% and the reduced temperature instability of the total focusing current is 0.004%. The employment of the converter to correct the dimension and shape of the CRT spot makes it possible to reduce the spot diameter to 18 μm at the center of the face and 22 μm at the edges of the face operating field

  6. Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

    Directory of Open Access Journals (Sweden)

    Nickenig Georg

    2009-05-01

    Full Text Available Abstract Background Wrist blood pressure (BP devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using etablished validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. Methods To compare the reproducibility of three different(BP measurement methods: 1 office BP, 2 home BP (Omron wrist device HEM- 637 IT with position sensor, 3 24-hour ambulatory BP(24-h ABPM (ABPM-04, Meditech, Hunconventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coeffcient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH- guidelines. Results The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differeces of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p Conclusion The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targed organ damage as recently reported for upper arm devices. Although wrist devices have to be used cautious and with defined limitations, the use of validated devices with position sensor according to recently recommended measurement schedules might have the potential to be used for therapy monitoring.

  7. Automatic measurement system for light element isotope analysis

    International Nuclear Information System (INIS)

    Satake, Hiroshi; Ikegami, Kouichi.

    1990-01-01

    The automatic measurement system for the light element isotope analysis was developed by installing the specially designed inlet system which was controlled by a computer. The microcomputer system contains specific interface boards for the inlet system and the mass spectrometer, Micromass 602 E. All the components of the inlet and the computer system installed are easily available in Japan. Ten samples can be automatically measured as a maximum of. About 160 minutes are required for 10 measurements of δ 18 O values of CO 2 . Thus four samples can be measured per an hour using this system, while usually three samples for an hour using the manual operation. The automatized analysis system clearly has an advantage over the conventional method. This paper describes the details of this automated system, such as apparatuses used, the control procedure and the correction for reliable measurement. (author)

  8. Micron system for automatization and analysis of measurements in nuclear photoemulsion

    International Nuclear Information System (INIS)

    Dajon, M.I.; Kotel'nikov, K.A.; Martynov, A.G.; Rappoport, V.M.; Smirnitskij, V.A.; Ozerskij, M.A.

    1987-01-01

    The automatized ''Micron'' system designed for measuring, processing and analyzing events in nuclear photoemulsion is described. The flowsheets of the device, program packages for searching neutrino interactions in nuclear photoemulsion and plotting target diagrams in X-ray emulsion chambers are presented. The ''Micron'' system consists of the following functional units: a three-coordinate measuring microscope MPEh-11 combined with a coordinate recording unit, designed for measuring coordinates of grains in the emulsion and displaying them on a peripheral, a control unit based on ''Elektronika-60'' microcomputer, a controller KK-60 for connecting the CAMAC highway, an analog-to-digital display with the keyboard. The PDP-11/70 is the basic computer. The event of charmed Λ c + barion production followed by the Λ c + →Σ + π + π - decay observed in nuclear photoemulsion is described

  9. Automatic alignment device for focal spot measurements in the center of the field for mammography; Sistema automatico de alinhamento para avaliacao do ponto focal no centro do campo de equipamentos mamograficos

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Marcelo A.C.; Watanabe, Alex O.; Oliveira Junior, Paulo D.; Schiabel, Homero [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Dept. de Engenharia Eletrica], e-mail: mvieira@sc.usp.br

    2010-03-15

    Some quality control procedures used for mammography, such as focal spot evaluation, requires previous alignment of the measurement equipment with the X-ray central beam. However, alignment procedures are, in general, the most difficult task and the one that needs more time to be performed. Moreover, the operator sometimes is exposed to radiation during this procedure. This work presents an automatic alignment system for mammographic equipment that allows locating the central ray of the radiation beam and, immediately, aligns with it by dislocating itself automatically along the field. The system consists on a bidirectional moving device, connected to a CCD sensor for digital radiographic image acquisition. A computational analysis of a radiographic image, acquired at any position on the field, is performed in order to determine its positioning under the X-ray beam. Finally, a mechanical system for two moving directions, electronically controlled by a microcontroller under USB communication, makes the system to align automatically with the radiation beam central ray. The alignment process is fully automatic, fast and accurate, with no operator exposure to radiation, which allows a considerable time saving for quality control procedures achievement for mammography. (author)

  10. The AMIDA automatic content linking device: Just-in-time document retrieval in meetings

    NARCIS (Netherlands)

    Popescu-Belis, A.; Boertjes, E.M.; Kilgour, J.; Poller, P.; Castronovo, S.; Wilson, T.; Jaimes, A.; Carletta, J.

    2008-01-01

    The AMIDA Automatic Content Linking Device (ACLD) is a just-in-time document retrieval system for meeting environments. The ACLD listens to a meeting and displays information about the documents from the group's history that are most relevant to what is being said. Participants can view an outline

  11. Tension pneumothorax secondary to automatic mechanical compression decompression device.

    Science.gov (United States)

    Hutchings, A C; Darcy, K J; Cumberbatch, G L A

    2009-02-01

    The details are presented of the first published case of a tension pneumothorax induced by an automatic compression-decompression (ACD) device during cardiac arrest. An elderly patient collapsed with back pain and, on arrival of the crew, was in pulseless electrical activity (PEA) arrest. He was promptly intubated and correct placement of the endotracheal tube was confirmed by noting equal air entry bilaterally and the ACD device applied. On the way to the hospital he was noted to have absent breath sounds on the left without any change in the position of the endotracheal tube. Needle decompression of the left chest caused a hiss of air but the patient remained in PEA. Intercostal drain insertion in the emergency department released a large quantity of air from his left chest but without any change in his condition. Post-mortem examination revealed a ruptured abdominal aortic aneurysm as the cause of death. Multiple left rib fractures and a left lung laceration secondary to the use of the ACD device were also noted, although the pathologist felt that the tension pneumothorax had not contributed to the patient's death. It is recommended that a simple or tension pneumothorax should be considered when there is unilateral absence of breath sounds in addition to endobronchial intubation if an ACD device is being used.

  12. The Automatic Measurement of Targets

    DEFF Research Database (Denmark)

    Höhle, Joachim

    1997-01-01

    The automatic measurement of targets is demonstrated by means of a theoretical example and by an interactive measuring program for real imagery from a réseau camera. The used strategy is a combination of two methods: the maximum correlation coefficient and the correlation in the subpixel range...... interactive software is also part of a computer-assisted learning program on digital photogrammetry....

  13. Development of a device for continuous automatic monitoring of consolidation of fresh concrete. Final report

    International Nuclear Information System (INIS)

    Lee, P.L.; Eggert, G.J.

    1978-01-01

    Quality of portland cement concrete can be increased if water/cement ratios are reduced; however, this increase is only achieved if concrete is adequately consolidated. This study was conducted to develop a device to permit continuous automatic monitoring of the degree of consolidation during pavement construction. A literature search identified several candidate techniques, the most feasible being a nuclear backscatter technique to measure concrete density. A prototype instrument was developed with a 500mCi source of Cesium (137) and a sodium iodide/photomultiplier sensing unit. The sensor head is located 1 inch (25.4 mm) above the concrete. It is moved back and forth across the width of the pavement by a traversing mechanism mounted to the back of a slip-form paver. Density is recorded on chart paper. The CMD (Consolidation Monitoring Device) is capable of sensing and displaying changes in density while traversing over the pavement surface at 17 fpm (0.086 m/s). It can duplicate core density measurements within a + or -2-1 pcf (+ or -36 kg cu m) confidence range

  14. Automatic Adviser on stationary devices status identification and anticipated change

    Science.gov (United States)

    Shabelnikov, A. N.; Liabakh, N. N.; Gibner, Ya M.; Pushkarev, E. A.

    2018-05-01

    A task is defined to synthesize an Automatic Adviser to identify the automation systems stationary devices status using an autoregressive model of changing their key parameters. An applied model type was rationalized and the research objects monitoring process algorithm was developed. A complex of mobile objects status operation simulation and prediction results analysis was proposed. Research results are commented using a specific example of a hump yard compressor station. The work was supported by the Russian Fundamental Research Fund, project No. 17-20-01040.

  15. The application of charge-coupled device processors in automatic-control systems

    Science.gov (United States)

    Mcvey, E. S.; Parrish, E. A., Jr.

    1977-01-01

    The application of charge-coupled device (CCD) processors to automatic-control systems is suggested. CCD processors are a new form of semiconductor component with the unique ability to process sampled signals on an analog basis. Specific implementations of controllers are suggested for linear time-invariant, time-varying, and nonlinear systems. Typical processing time should be only a few microseconds. This form of technology may become competitive with microprocessors and minicomputers in addition to supplementing them.

  16. Design And Development Of An Automatic Single Phase Protective Device Using Ssr

    Directory of Open Access Journals (Sweden)

    Michael E.

    2017-10-01

    Full Text Available Since the discovery of energy safety has been a paramount subject matter. This we can see in todays electrical systems where protective devices such as fuse and circuit breakers are used to prevent fire hazards resulting from overload overvoltage and short circuits. However with all the revolution in technology these options may be considered less smart since the fuse made with wire strands calculated for specific current capacity faults permanently when the specified current rating is exceeded. While the circuit breaker which is made up of mechanical switch fails as a result of carbon forming and the wearing away of the contacts because of arcing. As a means of improvement this paper presents the design and development of an automatic single phase protective device using solid state relay SSR. This study is to ensure automatic cut off from power supply in cases of overvoltage above 240 V AC or when overload and short circuit current above 8amps is detected without permanent damage of a fuse placed along current path. Also the design will ensure that there is an automatic close circuit whenever the trigger switch is momentary switch is closed. The system is achieved via the use of PIC micro-controller current sensor and other discrete components. The system is tested and works well inhibiting the frequent faulting of fuses. It also helps to prevent hazard as a result of overvoltage overload and short circuit and ensures a close circuit when the trigger switch is closed.

  17. Connection of automatic integral multichannel monitor of aerosol concentration

    International Nuclear Information System (INIS)

    Krejci, M.; Stulik, P.

    1985-01-01

    The instrument consists of the actual aerosol concentration monitor with two equivalent inputs, of an electropneumatic sampling selector, an aerosol pump, an electropneumatic valve, and of an exhaust device. For integral operating mode the instrument allows rapid checking and indication of exceedance of the permissible aerosol concentration limit at any sampling point. Upon exceedance of the permissible concentration limit, the device automatically switches into the multichannel cyclic measurement mode while the sampling point is identified where the aerosol concentration was increased. An emergency is displayed if the permissible limit has been exceeded. Following removal of the source of dangerous aerosol concentration, the control unit automatically switches the device into the integral measurement mode. (J.B.)

  18. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  19. DEVELOPMENT OF THE LOAD MEASURING DEVICES TO DETERMINE THE RESIDUAL DEFORMATION OF THE ELASTIC SENSING ELEMENT

    Directory of Open Access Journals (Sweden)

    Ivan V. Antonets

    2018-01-01

    Full Text Available The main focus in the design of weighing and batching devices is to create a gravimetric technique, capable of providing not only mass measurement – weighing with the required accuracy and speed, but also automatic control of technological processes and their control and regulation. In this case, the opportunity of two-way communication with a computer when designing the load measuring devices is realized, allowing remote monitoring and solution of logical problems associated with the management process. Modern automatic weighing and batching devices are important parts of comprehensive automation in different branches of industry. Existing developments of electrical, electronic, computing and other branches of instrument engineering techniques allow to implement transformations of the measured quantity with a very high degree of accuracy. However, if the measured quantity in the weighing process is perceived by the elastic sensing element of low quality, then no matter how high the accuracy of further changes is; the characteristics of the elastic element will limit the accuracy of the instrument as a whole. Although the elastic elements are simple mechanical parts, and many types of elastic elements are known and are widely used for many decades, their performance often does not meet the requirements, and hampers the device creation of high accuracy classes. Growing requirements for primary transformer makes actual the problem solution of improving the quality of elastic sensing elements not only in the manufacture but in the design. This led to the appearance of projects aimed at the development of computational and experimental methods that have altered the methodology for the design of force measuring devices.

  20. Power Factor Improvement Using Automatic Power Factor Compensation (APFC Device for Medical Industries in Malaysia

    Directory of Open Access Journals (Sweden)

    Zaidi Maryam Nabihah

    2018-01-01

    Full Text Available This paper present the project designed to correcting power factor for medical industries in Malaysia automatically. Which with hope to make the cost and energy usage efficient, because the energy source are depleting due to increase in population. Power factor is the ratio of real power and apparent power. This definition is mathematically represented as kW/kVA where kW is active power and kVA is apparent power (active + reactive. Reactive power is the non-working power generated by the magnetic and inductive load to generate magnetic flux. The increase in reactive power increase the apparent power so the power factor will decrease. Low pF will cause the industry to meet high demand thus making it less efficient. The main aim of this project is to increasing the current power factor of medical industries from 0.85 to 0.90. Power factor compensation contribute to reduction in current-dependent losses and increase energy efficiency while expanding the reliability of planning for future energy network. As technology develops, the gradual cost and efficiency penalty should reduce. Therefore, automatic power factor compensation device should become cost-effective and smaller device over time. That is the reason this project is using programmable device as it is a miniature architecture device.

  1. Automatic control unit for neutron transmission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abdel-Kawy, A.; Eid, Y.; Ashry, A.; Mostafa, M.; Hamouda, I. (Atomic Energy Establishment, Inshas (Egypt). Reactor and Neutron Physics Dept.)

    1981-01-01

    An automatic transistorized unit has been designed to control the neutron transmission measurements carried out using the time-of-flight spectrometer. The function of the automatic unit is to control the measurements of the neutron counting rate distribution transmitted through a sample at a selected channel group of the time analyzer for a certain preadjusted time period. At the end of this time, the unit removes the sample out of the neutron beam, selects a second equal channel group of the time analyzer and provides the measurement of the neutron counting rate distribution for the same time period as in the case with the sample on. Such a measuring cycle can be repeated as much as the experiment requires. At the end of these cycles the stored information can be immediately obtained through the analyzer read out unit. It is found that the time of removing the sample out of the neutron beam or returning it back does not exceed 20 seconds instead of the five minutes required in case of manual operation. The most important advantages of using such an automatic unit are saving about 20 percent of the reactor operating time avoidng unnecessary radiation exposure of the experimentalists.

  2. A novel device for automatic withdrawal and accurate calibration of 99m-technetium radiopharmaceuticals to minimise radiation exposure to nuclear medicine staff and patient

    International Nuclear Information System (INIS)

    Nazififard, M.; Mahdizadeh, S.; Meigooni, A. S.; Alavi, M.; Suh, K. Y.

    2012-01-01

    A Joint Automatic Dispenser Equipment (JADE) has been designed and fabricated for automatic withdrawal and calibration of radiopharmaceutical materials. The thermoluminescent dosemeter procedures have shown a reduction in dose to the technician's hand with this novel dose dispenser system JADE when compared with the manual withdrawal of 99m Tc. This system helps to increase the precision of calibration and to minimise the radiation dose to the hands and body of the workers. This paper describes the structure of this device, its function and user-friendliness, and its efficacy. The efficacy of this device was determined by measuring the radiation dose delivered to the hands of the nuclear medicine laboratory technician. The user-friendliness of JADE has been examined. The automatic withdrawal and calibration offered by this system reduces the dose to the technician's hand to a level below the maximum permissible dose stipulated by the international protocols. This research will serve as a backbone for future study about the safe use of ionising radiation in medicine. (authors)

  3. UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; John L. Morrison; William H. Morrison

    2014-03-01

    Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of

  4. Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

    Science.gov (United States)

    Uen, Sakir; Fimmers, Rolf; Brieger, Miriam; Nickenig, Georg; Mengden, Thomas

    2009-01-01

    Background Wrist blood pressure (BP) devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using etablished validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. Methods To compare the reproducibility of three different(BP) measurement methods: 1) office BP, 2) home BP (Omron wrist device HEM- 637 IT with position sensor), 3) 24-hour ambulatory BP(24-h ABPM) (ABPM-04, Meditech, Hun)conventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coeffcient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH)- guidelines. Results The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differeces of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p ABPM (p ABPM was not significantly different (p = 0.80 systolic BP, p = 0.1 diastolic BP). The correlation coefficient of 24-h ABMP (r = 0.52) with left ventricular mass index was significantly higher than with office BP (r = 0.31). The difference between 24-h ABPM and home BP (r = 0.46) was not significant. Conclusion The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targed organ damage as recently reported for upper arm devices. Although wrist devices have

  5. 76 FR 58301 - Proposed Extension of Existing Information Collection; Automatic Fire Sensor and Warning Device...

    Science.gov (United States)

    2011-09-20

    ... Information Collection; Automatic Fire Sensor and Warning Device Systems; Examination and Test Requirements ACTION: Notice of request for public comments. SUMMARY: The Mine Safety and Health Administration (MSHA... public comment version of this information collection package. FOR FURTHER INFORMATION CONTACT: Roslyn B...

  6. Automatic Defect Detection of Fasteners on the Catenary Support Device Using Deep Convolutional Neural Network

    NARCIS (Netherlands)

    Chen, Junwen; Liu, Zhigang; Wang, H.; Nunez Vicencio, Alfredo; Han, Zhiwei

    2018-01-01

    The excitation and vibration triggered by the long-term operation of railway vehicles inevitably result in defective states of catenary support devices. With the massive construction of high-speed electrified railways, automatic defect detection of diverse and plentiful fasteners on the catenary

  7. Poster Abstract: Automatic Calibration of Device Attitude in Inertial Measurement Unit Based Traffic Probe Vehicles

    KAUST Repository

    Mousa, Mustafa; Sharma, Kapil; Claudel, Christian

    2016-01-01

    to replace them with inertial measurement units onboard vehicles, to estimate vehicle location and attitude using inertial data only. While promising, this technology requires one to carefully calibrate the orientation of the device inside the vehicle

  8. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  9. An automatic tension measurement system of MWPC wires

    International Nuclear Information System (INIS)

    D'Antone, I.; Lolli, M.; Torromeo, G.

    1992-01-01

    An electronic system is presented for automatic mechanical tension measurement to test wire chambers. The developed system works in the tension range from 50 g to 300 g; this large working range is obtained by using a microcontroller that performs a digital control on the bridge of an oscillator containing the wire of which the tension has to be measured. The microcontroller automatically brings the system towards the oscillation condition and subsequently, measuring the frequency, it evaluates, displays and sends to a host computer the value of the mechanical tension of the wires. The system is precise and allows fast measurements. A description of the hardware and software design is given. (orig.)

  10. Dynamic Anthropometry – Deffning Protocols for Automatic Body Measurement

    Directory of Open Access Journals (Sweden)

    Slavenka Petrak

    2017-12-01

    Full Text Available The paper presents the research on possibilities of protocol development for automatic computer-based determination of measurements on a 3D body model in defined dynamic positions. Initially, two dynamic body positions were defined for the research on dimensional changes of targeted body lengths and surface segments during body movement from basic static position into a selected dynamic body position. The assumption was that during body movement, specifi c length and surface dimensions would change significantly from the aspect of clothing construction and functionality of a garment model. 3D body scanning of a female test sample was performed in basic static and two defined dynamic positions. 3D body models were processed and measurement points were defined as a starting point for the determination of characteristic body measurements. The protocol for automatic computer measurement was defined for every dynamic body position by the systematic set of activities based on determined measurement points. The verification of developed protocols was performed by automatic determination of defined measurements on the test sample and by comparing the results with the conventional manual measurement.

  11. A new automatic design method to develop multilayer thin film devices for high power laser applications

    International Nuclear Information System (INIS)

    Sahoo, N.K.; Apparao, K.V.S.R.

    1992-01-01

    Optical thin film devices play a major role in many areas of frontier technology like development of various laser systems to the designing of complex and precision optical systems. Design and development of these devices are really challenging when they are meant for high power laser applications. In these cases besides desired optical characteristics, the devices are expected to satisfy a whole range of different needs like high damage threshold, durability etc. In the present work a novel completely automatic design method based on Modified Complex Method has been developed for designing of high power thin film devices. Unlike most of the other methods it does not need any suitable starting design. A quarterwave design is sufficient to start with. If required, it is capable of generating its own starting design. The computer code of the method is very simple to implement. This report discusses this novel automatic design method and presents various practicable output designs generated by it. The relative efficiency of the method along with other powerful methods has been presented while designing a broadband IR antireflection coating. The method is also incorporated with 2D and 3D electric field analysis programmes to produce high damage threshold designs. Some experimental devices developed using such designs are also presented in the report. (author). 36 refs., 41 figs

  12. Description and principles of use of an automatic control device usable, in particular, in analytical chemistry

    International Nuclear Information System (INIS)

    Rigaudiere, Roger; Jeanmaire, Lucien

    1969-01-01

    This note describes an automatic control device for the programming of about 20 different functions, chronologically and during a given time. Any voltage can be chosen at the output to perform the different functions. Three examples of utilisation taken in analytical chemistry are given to illustrate the possibilities offered by this device, but its domain of use is much more universal and independent of the type of functions [fr

  13. Automatic refueling platform and CRD remote handling device for BWR plant

    International Nuclear Information System (INIS)

    Kato, Hiroaki; Takagi, Kaoru

    1978-01-01

    In BWR plants, machines for replacing fuel assemblies and control rod drives are usually operated directly by personnel. An automatic refueling platform and a CRD remote handling device aiming at radiation exposure reduction and handling perfectness are described, which are already used in BWR plants. Automation of the former is achieved in transporting fuel assemblies between a reactor pressure vessel and a fuel storage pool, shuffling fuel assemblies in a reactor core and moving fuel assemblies in a fuel storage pool. In the latter, replacement of CRDs is nearly all performed remotely. (Mori, K.)

  14. A new portable device for automatic controlled-gradient cryopreservation of blood mononuclear cells.

    Science.gov (United States)

    Hviid, L; Albeck, G; Hansen, B; Theander, T G; Talbot, A

    1993-01-04

    Protection of the functional integrity of mononuclear cells stored in liquid N2 requires careful control of the freezing procedure. Consequently, optimal quality of cryopreserved cells is usually assured by freezing according to a specified time-temperature gradient generated by computer-controlled freezing devices. While such equipment offers large capacity and secures maximum survival and functional integrity of the lymphocytes upon thawing, it is quite costly and strictly stationary. We have previously developed and tested an alternative, manual device for controlled-gradient lymphocyte freezing, which has proved suitable for field conditions. We report here the development and testing of a similar micro-controller regulated device, allowing unattended and automatic controlled-gradient cell freezing. The equipment exploits the temperature gradient present between the liquid N2 surface and the neck in an ordinary liquid N2 refrigerator. The lymphocyte samples are placed in a small elevator, which is moved through the N2 gas phase by a stepper motor. Time and temperature are measured at regular intervals, and the position of the samples adjusted to ensure that the actual measurements closely match encoded ideal values. Results of assays of the functional integrity and phenotypic composition of human mononuclear cells frozen by the new system were comparable to those obtained when using cells frozen by a commercially available, stationary cell-freezing equipment, or fresh autologous cell samples tested in parallel. Furthermore, there was a good correlation between functional and phenotypic data obtained using frozen and autologous fresh samples of mononuclear cells. The equipment described is low weight and has low N2 consumption, and is thus suitable for the collection and cryopreservation of lymphocytes under field conditions. Furthermore, the technique provides an inexpensive alternative for researchers with a limited requirement for the simultaneous freezing of

  15. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  16. POLYP: an automatic device for drawing sequential samples of gas

    Energy Technology Data Exchange (ETDEWEB)

    Gaglione, P; Koechler, C; Stanchi, L

    1974-12-01

    Polyp is an automatic device consisting of electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. The other seven pumps will inflate sequentially the other bags. The instrument is powered by rechargeable batteries and realized with C-MUS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof.

  17. POLYP: an automatic device for drawing sequential samples of gas

    International Nuclear Information System (INIS)

    Gaglione, P.; Koechler, C.; Stanchi, L.

    1974-12-01

    POLYP is an automatic device consisting of an electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. Thereafter the other seven pumps will inflate sequentially the other bag. The instrument is powered by rechargeable batteries and realized with C-MOS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof

  18. Automatic continuous dew point measurement in combustion gases

    Energy Technology Data Exchange (ETDEWEB)

    Fehler, D.

    1986-08-01

    Low exhaust temperatures serve to minimize energy consumption in combustion systems. This requires accurate, continuous measurement of exhaust condensation. An automatic dew point meter for continuous operation is described. The principle of measurement, the design of the measuring system, and practical aspects of operation are discussed.

  19. An automatic measuring system of internal friction at low frequency

    International Nuclear Information System (INIS)

    Iwasaki, K.

    1979-01-01

    An inverted torsion pendulum is automatized by means of Tectanel electronic system. Internal friction and the period of vibration are measured fully automatically as a function of temperature and the data obtained are analysed with a computer. (Author) [pt

  20. Large - scale Rectangular Ruler Automated Verification Device

    Science.gov (United States)

    Chen, Hao; Chang, Luping; Xing, Minjian; Xie, Xie

    2018-03-01

    This paper introduces a large-scale rectangular ruler automated verification device, which consists of photoelectric autocollimator and self-designed mechanical drive car and data automatic acquisition system. The design of mechanical structure part of the device refer to optical axis design, drive part, fixture device and wheel design. The design of control system of the device refer to hardware design and software design, and the hardware mainly uses singlechip system, and the software design is the process of the photoelectric autocollimator and the automatic data acquisition process. This devices can automated achieve vertical measurement data. The reliability of the device is verified by experimental comparison. The conclusion meets the requirement of the right angle test procedure.

  1. Automaticity of walking: functional significance, mechanisms, measurement and rehabilitation strategies

    Directory of Open Access Journals (Sweden)

    David J Clark

    2015-05-01

    Full Text Available Automaticity is a hallmark feature of walking in adults who are healthy and well-functioning. In the context of walking, ‘automaticity’ refers to the ability of the nervous system to successfully control typical steady state walking with minimal use of attention-demanding executive control resources. Converging lines of evidence indicate that walking deficits and disorders are characterized in part by a shift in the locomotor control strategy from healthy automaticity to compensatory executive control. This is potentially detrimental to walking performance, as an executive control strategy is not optimized for locomotor control. Furthermore, it places excessive demands on a limited pool of executive reserves. The result is compromised ability to perform basic and complex walking tasks and heightened risk for adverse mobility outcomes including falls. Strategies for rehabilitation of automaticity are not well defined, which is due to both a lack of systematic research into the causes of impaired automaticity and to a lack of robust neurophysiological assessments by which to gauge automaticity. These gaps in knowledge are concerning given the serious functional implications of compromised automaticity. Therefore, the objective of this article is to advance the science of automaticity of walking by consolidating evidence and identifying gaps in knowledge regarding: a functional significance of automaticity; b neurophysiology of automaticity; c measurement of automaticity; d mechanistic factors that compromise automaticity; and e strategies for rehabilitation of automaticity.

  2. Diagnostic performance of an automatic blood pressure measurement device, Microlife WatchBP Home A, for atrial fibrillation screening in a real-world primary care setting.

    Science.gov (United States)

    Chan, Pak-Hei; Wong, Chun-Ka; Pun, Louise; Wong, Yu-Fai; Wong, Michelle Man-Ying; Chu, Daniel Wai-Sing; Siu, Chung-Wah

    2017-06-15

    To evaluate the diagnostic performance of a UK National Institute for Health and Care Excellence-recommended automatic oscillometric blood pressure (BP) measurement device incorporated with an atrial fibrillation (AF) detection algorithm (Microlife WatchBP Home A) for real-world AF screening in a primary healthcare setting. Primary healthcare setting in Hong Kong. This was a prospective AF screening study carried out between 1 September 2014 and 14 January 2015. The Microlife device was evaluated for AF detection and compared with a reference standard of lead-I ECG. Diagnostic performance of Microlife for AF detection. 5969 patients (mean age: 67.2±11.0 years; 53.9% female) were recruited. The mean CHA 2 DS 2 -VASc ( C : congestive heart failure [1 point]; H : hypertension [1 point]; A 2 : age 65-74 years [1 point] and age ≥75 years [2 points]; D : diabetes mellitus [1 point]; S : prior stroke or transient ischemic attack [2 points]; VA : vascular disease [1 point]; and Sc : sex category [female] [1 point])score was 2.8±1.3. AF was diagnosed in 72 patients (1.21%) and confirmed by a 12-lead ECG. The Microlife device correctly identified AF in 58 patients and produced 79 false-positives. The corresponding sensitivity and specificity for AF detection were 80.6% (95% CI 69.5 to 88.9) and 98.7% (95% CI 98.3 to 98.9), respectively. Among patients with a false-positive by the Microlife device, 30.4% had sinus rhythm, 35.4% had sinus arrhythmia and 29.1% exhibited premature atrial complexes. With the low prevalence of AF in this population, the positive and negative predictive values of Microlife device for AF detection were 42.4% (95% CI 34.0 to 51.2) and 99.8% (95% CI 99.6 to 99.9), respectively. The overall diagnostic performance of Microlife device to detect AF as determined by area under the curves was 0.90 (95% CI 0.89 to 0.90). In the primary care setting, Microlife WatchBP Home was an effective means to screen for AF, with a reasonable sensitivity of 80.6% and

  3. Control and Data Analysis for Emittance Measuring Devices

    CERN Document Server

    Hoffmann, T

    2001-01-01

    Due to the wide range of heavy ion beam intensities and energies in the GSI linac and the associated transfer channel to the synchrotron, several different types of emittance measurement systems have been established. Many common devices such as slit/grid or dipole-sweep systems are integrated into the GSI control system. Other systems like the single shot pepper pot method using CCD-cameras or stand-alone slit/grid set-ups are connected to personal computers. An overview is given about the various systems and their software integration. Main interest is directed on the software development for emittance front-end control and data analysis such as evaluation algorithms or graphical presentation of the results. In addition, special features for improved usability of the software such as data export, project databases and automatic report generation will be presented. An outlook on a unified evaluation procedure for all different types of emittance measurement is given.

  4. A microfluidic-based lid device for conventional cell culture dishes to automatically control oxygen level.

    Science.gov (United States)

    Lee, Seung Yeob; Yang, Sung

    2018-04-25

    Most conventional hypoxic cell culture systems undergo reoxygenation during experimental manipulations, resulting in undesirable effects including the reduction of cell viability. A lid device was developed herein for conventional cell culture dishes to resolve this limitation. The integration of multilayered microfluidic channels inside a thin membrane was designed to prevent the reoxygenation caused by reagent infusion and automatically control the oxygen level. The experimental data clearly show the reducibility of the dissolved oxygen in the infusing reagent and the controllability of the oxygen level inside the dish. The feasibility of the device for hypoxia studies was confirmed by HIF-1α experiments. Therefore, the device could be used as a compact and convenient hypoxic cell culture system to prevent reoxygenation-related issues.

  5. The Siegen automatic measuring system for track detectors: new developments

    International Nuclear Information System (INIS)

    Rusch, G.; Winkel, E.; Noll, A.; Heinrich, W.

    1991-01-01

    Starting twelve years ago we have developed completely automatic scanning and measuring systems for nuclear track detectors. The hardware and software of these systems have continuously been improved. They were used in different heavy ion and cosmic ray experiments. In this paper we describe methods for high resolution REL measurements in plastic nuclear track detectors and methods to scan and measure nuclear disintegration stars in AgCl detectors using an automatic measuring technique. The system uses a stepping motor driven microscope stage, a video camera and an image analysis computer based on a MC68020 microprocessor. (author)

  6. Neutron measuring device

    International Nuclear Information System (INIS)

    Hatayama, Akiyoshi; Seki, Eiji; Kita, Yoshio; Nishitani, Takeo.

    1993-01-01

    The device of the present invention concerns measurement for neutrons in a tokamak type thermonuclear device and it can measure total amount of generated neutrons accurately throughout the operation period even if an error is caused in counted values by plasma disruption. That is, the device comprises (1) a means for detecting presence or absence of occurrence of plasma disruption and the time for the initiation of the occurrence, (2) a first data processing means for processing detection signals, (3) a means for detecting neutrons generated in plasmas and (4) a second data processing means for calculating integrated values for the number of neutrons generated from the start to the completion of electric discharge when no disruption occurs and calculating integrated values for the number of generated neutrons from the start of electric discharge to the time at the initiation of occurrence of the disruption when disruption is present. In the thus constituted device, even if an error is caused by frequent occurrence of plasma disruption, total time integrated amount of neutrons generated in the plasmas can be measured accurately. (I.S.)

  7. Automatic Morphological Sieving: Comparison between Different Methods, Application to DNA Ploidy Measurements

    Directory of Open Access Journals (Sweden)

    Christophe Boudry

    1999-01-01

    Full Text Available The aim of the present study is to propose alternative automatic methods to time consuming interactive sorting of elements for DNA ploidy measurements. One archival brain tumour and two archival breast carcinoma were studied, corresponding to 7120 elements (3764 nuclei, 3356 debris and aggregates. Three automatic classification methods were tested to eliminate debris and aggregates from DNA ploidy measurements (mathematical morphology (MM, multiparametric analysis (MA and neural network (NN. Performances were evaluated by reference to interactive sorting. The results obtained for the three methods concerning the percentage of debris and aggregates automatically removed reach 63, 75 and 85% for MM, MA and NN methods, respectively, with false positive rates of 6, 21 and 25%. Information about DNA ploidy abnormalities were globally preserved after automatic elimination of debris and aggregates by MM and MA methods as opposed to NN method, showing that automatic classification methods can offer alternatives to tedious interactive elimination of debris and aggregates, for DNA ploidy measurements of archival tumours.

  8. Automatic system for ionization chamber current measurements

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro S.; Koskinas, Marina F.

    2004-01-01

    The present work describes an automatic system developed for current integration measurements at the Laboratorio de Metrologia Nuclear of Instituto de Pesquisas Energeticas e Nucleares. This system includes software (graphic user interface and control) and a module connected to a microcomputer, by means of a commercial data acquisition card. Measurements were performed in order to check the performance and for validating the proposed design

  9. Development and application of an automatic system for measuring the laser camera

    International Nuclear Information System (INIS)

    Feng Shuli; Peng Mingchen; Li Kuncheng

    2004-01-01

    Objective: To provide an automatic system for measuring imaging quality of laser camera, and to make an automatic measurement and analysis system. Methods: On the special imaging workstation (SGI 540), the procedure was written by using Matlab language. An automatic measurement and analysis system of imaging quality for laser camera was developed and made according to the imaging quality measurement standard of laser camera of International Engineer Commission (IEC). The measurement system used the theories of digital signal processing, and was based on the characteristics of digital images, as well as put the automatic measurement and analysis of laser camera into practice by the affiliated sample pictures of the laser camera. Results: All the parameters of imaging quality of laser camera, including H-D and MTF curve, low and middle and high resolution of optical density, all kinds of geometry distort, maximum and minimum density, as well as the dynamic range of gray scale, could be measured by this system. The system was applied for measuring the laser cameras in 20 hospitals in Beijing. The measuring results showed that the system could provide objective and quantitative data, and could accurately evaluate the imaging quality of laser camera, as well as correct the results made by manual measurement based on the affiliated sample pictures of the laser camera. Conclusion: The automatic measuring system of laser camera is an effective and objective tool for testing the quality of the laser camera, and the system makes a foundation for the future research

  10. Coherence measures in automatic time-migration velocity analysis

    International Nuclear Information System (INIS)

    Maciel, Jonathas S; Costa, Jessé C; Schleicher, Jörg

    2012-01-01

    Time-migration velocity analysis can be carried out automatically by evaluating the coherence of migrated seismic events in common-image gathers (CIGs). The performance of gradient methods for automatic time-migration velocity analysis depends on the coherence measures used as the objective function. We compare the results of four different coherence measures, being conventional semblance, differential semblance, an extended differential semblance using differences of more distant image traces and the product of the latter with conventional semblance. In our numerical experiments, the objective functions based on conventional semblance and on the product of conventional semblance with extended differential semblance provided the best velocity models, as evaluated by the flatness of the resulting CIGs. The method can be easily extended to anisotropic media. (paper)

  11. The application of computer and automatic technology in dose measurement of neutron radiation

    International Nuclear Information System (INIS)

    Zhou Yu; Li Chenglin; Luo Yisheng; Guo Yong; Chen Di; Xiaojiang

    1999-01-01

    Generally the dose measurement of neutron radiation requires three electrometers, two bias, three workers in the same time. To improve the accuracy and efficiency of measurement, a Model 6517A electrometer that accommodate Model 6521 scanner cards and a portable computer are used to make up of a automatic measurement system. Corresponding software is developed and used to control it. Because of the application of computer and automatic technology, this system can not only measure dose rate automatically, but also make data's calculating, saving, querying, printing and comparing ease

  12. Electronic cooling using an automatic energy transport device based on thermomagnetic effect

    International Nuclear Information System (INIS)

    Xuan Yimin; Lian Wenlei

    2011-01-01

    Liquid cooling for thermal management has been widely applied in electronic cooling. The use of mechanical pumps often leads to poor reliability, high energy consumption and other problems. This paper presents a practical design of liquid cooling system by mean of thermomagnetic effect of magnetic fluids. The effects of several structure and operation factors on the system performance are also discussed. Such a device utilizes an earth magnet and the waste heat generated from a chip or other sources to maintain the flow of working fluid which transfers heat to a far end for dissipation. In the present cooling device, no additional energy other than the waste heat dissipated is consumed for driving the cooling system and the device can be considered as completely self-powered. Application of such a cooling system to a hot chip results in an obvious temperature drop of the chip surface. As the heat load increases, a larger heat dissipation rate can be realized due to a stronger thermomagnetic convection, which indicates a self-regulating feature of such devices. - Research highlights: → Automatic electronic cooling has been realized by means of thermomagnetic effect. → Application of the cooling system to a hot chip results in an obvious surface temperature drop. → The system possesses a self-regulating feature of cooling performance.

  13. An automatic device for the quality control of large-scale crystal's production

    CERN Document Server

    Baccaro, S; Castellani, M; Cecilia, A; Dafinei, I; Diemoz, M; Guerra, S; Longo, E; Montecchi, M; Organtini, G; Pellegrini, F

    2001-01-01

    In 1999, the construction of the electromagnetic calorimeter of the Compact Muon Solenoid (CMS) experiment started. Half of the barrel calorimeter made of 61200 lead tungstate (PWO) crystals will be assembled and tested in the Regional Centre of INFN-ENEA in Rome, Italy. Before assembling, all 30600 PWO crystals will be qualified for scintillation and radiation hardness characteristics by a specially built Automatic Crystal Control System. The measuring techniques for crystal qualification and performances of the automatic system will be discussed in this work. (11 refs).

  14. Investigation and realization of an automatic device for the control and test of a photon tagging system

    International Nuclear Information System (INIS)

    Fallou, J.L.

    1987-12-01

    An intelligent control/test equipment for a monoenergetic photon production system was developed. The device enables simulations to be done outside experimental runs. Operation can be entirely automatic, or controlled by the experimenters. The device is modular and conforms to CAMAC standards. The architecture of the system is based around a local bus which comprises a central unit and its memory; a programmable pulse generator; a switching circuit to test and control the various paths; and a unit to communicate with the acquisition system [fr

  15. Automatic measurement of the radioactive mercury uptake by the kidney

    International Nuclear Information System (INIS)

    Zurowski, S.; Raynaud, C.; CEA, 91 - Orsay

    1976-01-01

    An entirely automatic method to measure the Hg uptake by the kidney is proposed. The following operations are carried out in succession: measurement of extrarenal activity, demarcation of uptake areas, anatomical identification of uptake areas, separation of overlapping organ images and measurement of kidney depth. The first results thus calculated on 30 patients are very close to those obtained with a standard manual method and are highly encouraging. Two important points should be stressed: a broad demarcation of the uptake areas is necessary and an original method, that of standard errors, is useful for the background noise determination and uptake area demarcation. This automatic measurement technique is so designed that it can be applied to other special cases [fr

  16. Control method and device for automatic drift stabilization in radiation detection

    International Nuclear Information System (INIS)

    Berthold, F.; Kubisiak, H.

    1979-01-01

    In the automatic control circuit individual electron peaks in the detectors, e.g. NaI crystals or proportional counters, are used. These peaks exhibit no drift dependence; they may be produced in the detectors in different ways. The control circuit may be applied in nuclear radiation measurement techniques, photometry, gamma cameras and for measuring the X-ray fine structure with proportional counters. (DG) [de

  17. Process and device for automatic control of air ratio in combustion

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, F J; Holick, H

    1976-06-24

    The device concerns a process for the automatic control of the air ratio in combustion, by setting the fuel-air mixture for combustion depending on the air number lambda. The control of the air ratio of combustion engines is carried out using a zirconium dioxide measuring probe, which is situated in the exhaust gas. It is a disadvantage that this is only sensitive for an air number lambda of 1. In order to achieve control of the air ratio for air numbers greater or smaller than 1, according to the invention an auxiliary gas is mixed with the hot exhaust gas, or a component of the gas is withdrawn, so that a corrected exhaust gas flow is produced, whose air number is detected by the measuring sensor and controlled to a value of about 1. The auxiliary gas flow is chosen so that an air ratio differing from lambda equals 1 is formed when the air number of the corrected exhaust gas flow is regulated to a value of lambda equals 1 approximately. In order to keep the demand for auxiliary gas low, only part of the exhaust gas flow is used for the measurement. The exhaust gas part flow is kept constant while the auxiliary gas flow or the removed component of gas flow are altered. Hydrogen or oxygen are used as auxiliary gases, depending whether excess or reduced air is required. Instead of hydrogen, fuel or its combustion products can be used. According to the invention, the hydrogen or oxygen can be produced electrolytically. Dosing takes place by the current used for electrolysis.

  18. A New Device to Automate the Monitoring of Critical Patients’ Urine Output

    Directory of Open Access Journals (Sweden)

    Abraham Otero

    2014-01-01

    Full Text Available Urine output (UO is usually measured manually each hour in acutely ill patients. This task consumes a substantial amount of time. Furthermore, in the literature there is evidence that more frequent (minute-by-minute UO measurement could impact clinical decision making and improve patient outcomes. However, it is not feasible to manually take minute-by-minute UO measurements. A device capable of automatically monitoring UO could save precious time of the healthcare staff and improve patient outcomes through a more precise and continuous monitoring of this parameter. This paper presents a device capable of automatically monitoring UO. It provides minute by minute measures and it can generate alarms that warn of deviations from therapeutic goals. It uses a capacitive sensor for the measurement of the UO collected within a rigid container. When the container is full, it automatically empties without requiring any internal or external power supply or any intervention by the nursing staff. In vitro tests have been conducted to verify the proper operation and accuracy in the measures of the device. These tests confirm the viability of the device to automate the monitoring of UO.

  19. Design and study of ultrasound-based automatic patient movement monitoring device for quantifying the intrafraction motion during teletherapy treatment.

    Science.gov (United States)

    Senthilkumar, S; Vinothraj, R

    2012-11-08

    The aim of the present study is to fabricate indigenously ultrasonic-based automatic patient's movement monitoring device (UPMMD) that immediately halts teletherapy treatment if a patient moves, claiming accurate field treatment. The device consists of circuit board, magnetic attachment device, LED indicator, speaker, and ultrasonic emitter and receiver, which are placed on either side of the treatment table. The ultrasonic emitter produces the ultrasound waves and the receiver accepts the signal from the patient. When the patient moves, the receiver activates the circuit, an audible warning sound will be produced in the treatment console room alerting the technologist to stop treatment. Simultaneously, the electrical circuit to the teletherapy machine will be interrupted and radiation will be halted. The device and alarm system can detect patient movements with a sensitivity of about 1 mm. Our results indicate that, in spite of its low-cost, low-power, high-precision, nonintrusive, light weight, reusable and simplicity features, UPMMD is highly sensitive and offers accurate measurements. Furthermore, UPMMD is patient-friendly and requires minimal user training. This study revealed that the device can prevent the patient's normal tissues from unnecessary radiation exposure, and also it is helpful to deliver the radiation to the correct tumor location. Using this alarming system the patient can be repositioned after interrupting the treatment machine manually. It also enables the technologists to do their work more efficiently.

  20. Automatic emissive probe apparatus for accurate plasma and vacuum space potential measurements

    Science.gov (United States)

    Jianquan, LI; Wenqi, LU; Jun, XU; Fei, GAO; Younian, WANG

    2018-02-01

    We have developed an automatic emissive probe apparatus based on the improved inflection point method of the emissive probe for accurate measurements of both plasma potential and vacuum space potential. The apparatus consists of a computer controlled data acquisition card, a working circuit composed by a biasing unit and a heating unit, as well as an emissive probe. With the set parameters of the probe scanning bias, the probe heating current and the fitting range, the apparatus can automatically execute the improved inflection point method and give the measured result. The validity of the automatic emissive probe apparatus is demonstrated in a test measurement of vacuum potential distribution between two parallel plates, showing an excellent accuracy of 0.1 V. Plasma potential was also measured, exhibiting high efficiency and convenient use of the apparatus for space potential measurements.

  1. Automatic ultrasound technique to measure angle of progression during labor.

    Science.gov (United States)

    Conversano, F; Peccarisi, M; Pisani, P; Di Paola, M; De Marco, T; Franchini, R; Greco, A; D'Ambrogio, G; Casciaro, S

    2017-12-01

    To evaluate the accuracy and reliability of an automatic ultrasound technique for assessment of the angle of progression (AoP) during labor. Thirty-nine pregnant women in the second stage of labor, with fetus in cephalic presentation, underwent conventional labor management with additional translabial sonographic examination. AoP was measured in a total of 95 acquisition sessions, both automatically by an innovative algorithm and manually by an experienced sonographer, who was blinded to the algorithm outcome. The results obtained from the manual measurement were used as the reference against which the performance of the algorithm was assessed. In order to overcome the common difficulties encountered when visualizing by sonography the pubic symphysis, the AoP was measured by considering as the symphysis landmark its centroid rather than its distal point, thereby assuring high measurement reliability and reproducibility, while maintaining objectivity and accuracy in the evaluation of progression of labor. There was a strong and statistically significant correlation between AoP values measured by the algorithm and the reference values (r = 0.99, P < 0.001). The high accuracy provided by the automatic method was also highlighted by the corresponding high values of the coefficient of determination (r 2  = 0.98) and the low residual errors (root mean square error = 2°27' (2.1%)). The global agreement between the two methods, assessed through Bland-Altman analysis, resulted in a negligible mean difference of 1°1' (limits of agreement, 4°29'). The proposed automatic algorithm is a reliable technique for measurement of the AoP. Its (relative) operator-independence has the potential to reduce human errors and speed up ultrasound acquisition time, which should facilitate management of women during labor. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

  2. Mobile Genome Express (MGE: A comprehensive automatic genetic analyses pipeline with a mobile device.

    Directory of Open Access Journals (Sweden)

    Jun-Hee Yoon

    Full Text Available The development of next-generation sequencing (NGS technology allows to sequence whole exomes or genome. However, data analysis is still the biggest bottleneck for its wide implementation. Most laboratories still depend on manual procedures for data handling and analyses, which translates into a delay and decreased efficiency in the delivery of NGS results to doctors and patients. Thus, there is high demand for developing an automatic and an easy-to-use NGS data analyses system. We developed comprehensive, automatic genetic analyses controller named Mobile Genome Express (MGE that works in smartphones or other mobile devices. MGE can handle all the steps for genetic analyses, such as: sample information submission, sequencing run quality check from the sequencer, secured data transfer and results review. We sequenced an Actrometrix control DNA containing multiple proven human mutations using a targeted sequencing panel, and the whole analysis was managed by MGE, and its data reviewing program called ELECTRO. All steps were processed automatically except for the final sequencing review procedure with ELECTRO to confirm mutations. The data analysis process was completed within several hours. We confirmed the mutations that we have identified were consistent with our previous results obtained by using multi-step, manual pipelines.

  3. Mobile Genome Express (MGE): A comprehensive automatic genetic analyses pipeline with a mobile device.

    Science.gov (United States)

    Yoon, Jun-Hee; Kim, Thomas W; Mendez, Pedro; Jablons, David M; Kim, Il-Jin

    2017-01-01

    The development of next-generation sequencing (NGS) technology allows to sequence whole exomes or genome. However, data analysis is still the biggest bottleneck for its wide implementation. Most laboratories still depend on manual procedures for data handling and analyses, which translates into a delay and decreased efficiency in the delivery of NGS results to doctors and patients. Thus, there is high demand for developing an automatic and an easy-to-use NGS data analyses system. We developed comprehensive, automatic genetic analyses controller named Mobile Genome Express (MGE) that works in smartphones or other mobile devices. MGE can handle all the steps for genetic analyses, such as: sample information submission, sequencing run quality check from the sequencer, secured data transfer and results review. We sequenced an Actrometrix control DNA containing multiple proven human mutations using a targeted sequencing panel, and the whole analysis was managed by MGE, and its data reviewing program called ELECTRO. All steps were processed automatically except for the final sequencing review procedure with ELECTRO to confirm mutations. The data analysis process was completed within several hours. We confirmed the mutations that we have identified were consistent with our previous results obtained by using multi-step, manual pipelines.

  4. Accuracy of two root canal length measurement devices integrated into rotary endodontic motors when removing gutta-percha from root-filled teeth.

    Science.gov (United States)

    Uzun, O; Topuz, O; Tinaz, C; Nekoofar, M H; Dummer, P M H

    2008-09-01

    To evaluate ex vivo the accuracy of the integrated electronic root canal length measurement devices within TCM Endo V and Tri Auto ZX motors whilst removing gutta-percha and sealer from filled root canals. Forty freshly extracted maxillary and mandibular incisor teeth with mature apices were selected. Following access cavity preparation, the length of the root canals were measured visually 0.5 mm short of the major foramen (TL). The canals were prepared using the HERO 642 system and then filled with gutta-percha and AH26 sealer using a lateral compaction technique. After 7 days the coronal temporary filling was removed and the roots mounted in an alginate experimental model. The roots were then randomly divided in two groups. The access cavities were filled with chloroform to soften the gutta-percha and allow its penetration using the Tri Auto ZX and the TCM Endo V devices in groups 1 and 2, respectively. The 'automatic apical reverse function' (ARL) of both devices was set to start at the 0.5 setting and the rotary instrument inserted inside the root canal until a beeping sound was heard and the rotation of the file stopped automatically. Once the auto reverse function had been initiated, the foot pedal of the motor was inactivated and the rubber stop placed against the reference point. The distance between the file tip and rubber stop was measured using a digital calliper to 0.01 mm accuracy (ARL). Then, a size 20, 0.02 taper instrument was attached to each device and inserted into the root canals without rotary motion until the integrated ERCLMDs positioned the instrument tips at the 0.5 setting as suggested by the devices. This length was again measured using a digital calliper (EL). The Mann-Whitney U-test was used to investigate statistical differences between the true canal length and those indicated by the two devices when used in 'automatic ARL and when inserted passively (EL). In the presence of gutta-percha, sealer and chloroform, the auto

  5. ANALYSIS OF EXISTING AND PROSPECTIVE TECHNICAL CONTROL SYSTEMS OF NUMERIC CODES AUTOMATIC BLOCKING

    Directory of Open Access Journals (Sweden)

    A. M. Beznarytnyy

    2013-09-01

    Full Text Available Purpose. To identify the characteristic features of the engineering control measures system of automatic block of numeric code, identifying their advantages and disadvantages, to analyze the possibility of their use in the problems of diagnosing status of the devices automatic block and setting targets for the development of new diagnostic systems. Methodology. In order to achieve targets the objective theoretical and analytical method and the method of functional analysis have been used. Findings. The analysis of existing and future facilities of the remote control and diagnostics automatic block devices had shown that the existing systems of diagnosis were not sufficiently informative, designed primarily to control the discrete parameters, which in turn did not allow them to construct a decision support subsystem. In developing of new systems of technical diagnostics it was proposed to use the principle of centralized distributed processing of diagnostic data, to include a subsystem support decision-making in to the diagnostics system, it will reduce the amount of work to maintain the devices blocking and reduce recovery time after the occurrence injury. Originality. As a result, the currently existing engineering controls facilities of automatic block can not provide a full assessment of the state distillation alarms and locks. Criteria for the development of new systems of technical diagnostics with increasing amounts of diagnostic information and its automatic analysis were proposed. Practical value. These results of the analysis can be used in practice in order to select the technical control of automatic block devices, as well as the further development of diagnostic systems automatic block that allows for a gradual transition from a planned preventive maintenance service model to the actual state of the monitored devices.

  6. Automatic ingestion monitor: a novel wearable device for monitoring of ingestive behavior.

    Science.gov (United States)

    Fontana, Juan M; Farooq, Muhammad; Sazonov, Edward

    2014-06-01

    Objective monitoring of food intake and ingestive behavior in a free-living environment remains an open problem that has significant implications in study and treatment of obesity and eating disorders. In this paper, a novel wearable sensor system (automatic ingestion monitor, AIM) is presented for objective monitoring of ingestive behavior in free living. The proposed device integrates three sensor modalities that wirelessly interface to a smartphone: a jaw motion sensor, a hand gesture sensor, and an accelerometer. A novel sensor fusion and pattern recognition method was developed for subject-independent food intake recognition. The device and the methodology were validated with data collected from 12 subjects wearing AIM during the course of 24 h in which both the daily activities and the food intake of the subjects were not restricted in any way. Results showed that the system was able to detect food intake with an average accuracy of 89.8%, which suggests that AIM can potentially be used as an instrument to monitor ingestive behavior in free-living individuals.

  7. Development of a doorframe-typed swinging seedling pick-up device for automatic field transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Han, H.; Mao, H.; Hu, J.; Tian, K.

    2015-07-01

    A doorframe-typed swing seedling pick-up device for automatic field transplanters was developed and evaluated in a laboratory. The device, consisting of a path manipulator and two grippers, can move the pins slowly to extract seedlings from the tray cells and return quickly to the pick-up point for the next extraction. The path manipulator was constructed with the creative design of type-Ⅱ mechanism combination in series. It consists of an oscillating guide linkage mechanism and a grooved globoidal cam mechanism. The gripper is a pincette-type mechanism using the pick-up pins to penetrate into the root mass for seedling extraction. The dynamic analysis of the designed seedling pick-up device was simulated with ADAMS software. Being the first prototype, various performance tests under local production conditions were conducted to find out the optimal machine operation parameters and transplant production conditions. As the gripper with multiple fine pins was moved by the swing pick-up device, it can effectively complete the transplanting work cycle of extracting, transferring, and discharging a seedling. The laboratory evaluation showed that the pick-up device equipped with two grippers can extract 80 seedlings/min with a 90% success and a 3% failure in discharging seedlings, using 42-day-old tomato plantlets. The quality of extracting seedlings was satisfactory. (Author)

  8. Radiation ray measuring device

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki; Ida, Masaki.

    1997-01-01

    The present invention provides a chained-radiation ray monitoring system which can be applied to an actual monitoring system of a nuclear power plant or the like. Namely, this device comprises a plurality of scintillation detectors. Each of the detectors has two light take-out ports for emitting light corresponding to radiation rays irradiated from the object of the measurement to optical fibers. In addition, incident light from the optical fiber by way of one of the light take-out optical ports is transmitted to the other of the ports and sent from the other optical port to the fibers. Plurality sets of measuring systems are provided in which each of the detectors are disposed corresponding to a plurality of objects to be measured. A signal processing device is (1) connected with optical fibers of plurality sets of measuring systems in conjunction, (2) detects the optical pulses inputted from the optical fibers to identify the detector from which the optical pulses are sent and (3) measures the amount of radiation rays detected by the identified detector. As a result, the device of the present invention can form a measuring system with redundancy. (I.S.)

  9. BORILAIN. Mobile device for automatic continuous supply of liquid injection system backup of a nuclear plant in emergency

    International Nuclear Information System (INIS)

    Lacalle, J.; Traino, J.; Troeung, J.; Arnaldos, A.; Alcaraz, D. A.; Lopez, B.; Ponce, A. T.

    2014-01-01

    This paper presents the design and development of the first automatic mobile device for the preparation of a neutron absorbing solution, and providing continuous, 30 days, of the injection system liquid reserve of a nuclear emergency. The work has been developed by GD Energy Services (GDES) for Electricite de France (EDF). (Author)

  10. Study of deflection and crack interrelation that use deck slab's automatic measurement

    International Nuclear Information System (INIS)

    Park, Sung Woo; Park, Yung Suk; Joo, Kwon Yong

    2004-01-01

    Reinforce concrete slab executes finish work if 6 - 8 hours pass since concrete placing. Specially, because minimize process composition slab occasion early space-time that use structure deck plate, concrete strength revelation is very important. The reason is that when strength revelation is not made, fine shock and deflection can provoke concrete crack. Executed radio automatic measure to prevent these crack initiation cause in the advance. Apply radio automatic measure is il-san culture center building and pasta measure period 03/09/06 - 03/10/08.

  11. The Total Deviation Index estimated by Tolerance Intervals to evaluate the concordance of measurement devices

    Directory of Open Access Journals (Sweden)

    Ascaso Carlos

    2010-04-01

    Full Text Available Abstract Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.

  12. Temperature measuring device

    International Nuclear Information System (INIS)

    Brixy, H.

    1977-01-01

    The temperature measuring device is equipped with an electric resistor installed within a metal shroud tube so as to be insulated from it, the noise voltage of which resistor is fed to a measuring unit. The measuring junctions of one or two thermocouples are connected with the electric resistor and the legs of one or both thermocouples can be connected to the measuring unit by means of a switch. (orig.) [de

  13. The construction of the CMS electromagnetic calorimeter: automatic measurements of the physics parameters of PWO crystals

    CERN Multimedia

    2005-01-01

    Crystal properties (dimensions, optical transmission, light yield) are automatically measured. The pictures show different measurement stations of the automatic machine. Crystals are measured on trays containing five crystals each.

  14. Veal calves’ clinical/health status in large groups fed with automatic feeding devices

    Directory of Open Access Journals (Sweden)

    Giulio Cozzi

    2010-01-01

    Full Text Available Aim of the current study was to evaluate the clinical/health status of veal calves in 3 farms that adopt large group housing and automatic feeding stations in Italy. Visits were scheduled in three phases of the rearing cycle (early, middle, and end. Results showed a high incidence of coughing, skin infection and bloated rumen particularly in the middle phase while cross-sucking signs were present at the early stage when calves’ nibbling proclivity is still high. Throughout the rearing cycle, the frequency of bursitis increased reaching 53% of calves at the end. The percentage of calves with a poorer body condition than the mid-range of the batch raised gradually as well, likely due to the non-proportioned teat/calves ratio that increases competition for feed and reduces milk intake of the low ranking animals. The remarked growth differences among pen-mates and the mortality rate close to 7% showed by the use of automatic feeding devices for milk delivery seem not compensating the lower labour demand, therefore its sustainability at the present status is doubtful both for the veal calves’ welfare and the farm incomes.

  15. Automatic gamma radiation scanning device and feed mechanism for plural sample holders

    International Nuclear Information System (INIS)

    Byrd, W.J.

    1976-01-01

    Apparatus is disclosed for measuring the level of gamma radiation contained in a plurality of biological samples which are located on the fibrous sheet member carried by a sample holder. The apparatus is adapted to count the radiation level of the number of closely spaced samples located in rows and columns on the sheet by automatically sequencing through the individual samples within the rows and to advance the holder to bring successive rows into proximity with the detector. The detector is moved from sample to sample within the rows, although a number of detectors can be employed. A plurality of sample holders are automatically advanced to the detector. 25 claims, 5 drawing figures

  16. A semi-automatic technique for measurement of arterial wall from black blood MRI

    International Nuclear Information System (INIS)

    Ladak, Hanif M.; Thomas, Jonathan B.; Mitchell, J. Ross; Rutt, Brian K.; Steinman, David A.

    2001-01-01

    Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semi-automatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple

  17. Vital Recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices.

    Science.gov (United States)

    Lee, Hyung-Chul; Jung, Chul-Woo

    2018-01-24

    The current anaesthesia information management system (AIMS) has limited capability for the acquisition of high-quality vital signs data. We have developed a Vital Recorder program to overcome the disadvantages of AIMS and to support research. Physiological data of surgical patients were collected from 10 operating rooms using the Vital Recorder. The basic equipment used were a patient monitor, the anaesthesia machine, and the bispectral index (BIS) monitor. Infusion pumps, cardiac output monitors, regional oximeter, and rapid infusion device were added as required. The automatic recording option was used exclusively and the status of recording was frequently checked through web monitoring. Automatic recording was successful in 98.5% (4,272/4,335) cases during eight months of operation. The total recorded time was 13,489 h (3.2 ± 1.9 h/case). The Vital Recorder's automatic recording and remote monitoring capabilities enabled us to record physiological big data with minimal effort. The Vital Recorder also provided time-synchronised data captured from a variety of devices to facilitate an integrated analysis of vital signs data. The free distribution of the Vital Recorder is expected to improve data access for researchers attempting physiological data studies and to eliminate inequalities in research opportunities due to differences in data collection capabilities.

  18. 21 CFR 864.6400 - Hematocrit measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematocrit measuring device. 864.6400 Section 864.6400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6400 Hematocrit measuring...

  19. Development of a wireless blood pressure measuring device with smart mobile device.

    Science.gov (United States)

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. 32 CFR 634.27 - Speed-measuring devices.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Speed-measuring devices. 634.27 Section 634.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.27 Speed-measuring devices. Speed-measuring devices will be...

  1. Atmospheric diffusion wind tunnel with automatic measurement

    Energy Technology Data Exchange (ETDEWEB)

    Maki, S; Sakai, J; Murata, E

    1974-01-01

    A wind tunnel which permits estimates of atmospheric diffusion is described. Smoke from power plant smoke stacks, for example, can be simulated and traced to determine the manner of diffusion in the air as well as the grade of dilution. The wind tunnel is also capable of temperature controlled diffusion tests in which temperature distribution inside the wind tunnel is controlled. A minimum wind velocity of 10 cm can be obtained with accuracy within plus or minus 0.05 percent using a controlled direct current motor; diffusion tests are often made at low wind velocity. Fully automatic measurements can be obtained by using a minicomputer so that the operation and reading of the measuring instruments can be remotely controlled from the measuring chamber. (Air Pollut. Abstr.)

  2. Is there evidence for the added value and correct use of manual and automatically switching multimemory hearing devices? A scoping review

    NARCIS (Netherlands)

    de Graaff, Feike; Huysmans, Elke; Ket, Johannes C.F.; Merkus, Paul; Goverts, S. Theo; Leemans, C. René; Smits, Cas

    2018-01-01

    Objectives: To review literature on the use of manual and automatically switching multimemory devices by hearing aid and CI recipients, and to investigate if recipients appreciate and adequately use the ability to switch between programmes in various listening environments. Design: Literature was

  3. Automatic apparatus for measuring thermophysical quantities controlled by calculator EMG 666

    International Nuclear Information System (INIS)

    Kubicar, L.; Illekova, E.

    1984-01-01

    Automatic system for measuring thermal diffusivity, thermal conductivity and heat capacity of samples is described. Measurements are performed by the pulse method in the temperature range from -150 to 1500 deg C. The measuring CAMAC equipment connected with the EMG 666 computer. Data processing is carried out by 100-400 measurement points (measuring cycle) for the whole temperature range

  4. Propagation Measurements for Device-to-Device Communication in Forest Terrain

    DEFF Research Database (Denmark)

    Hejselbæk, Johannes; Nielsen, Jesper Ødum; Drewes, Christian

    2018-01-01

    In this paper, we present a measurement campaign conducted in forest terrain with focus on path-loss. The aim of the measurement campaign is to study the coverage in a Device-to-Device (D2D) communication scenario. The measurement campaign was conducted in the LTE band 8 at 917.5 MHz...... with measurement ranges extending to more than 2.5 km. The measurements have been conducted using a purpose-developed measurement system with a dynamic range of 180 dB. The measurements showed that a D2D system with transmit and receive antenna at heights of 1.5 m could achieve a range of approximately 2 km using...

  5. Coating thickness measuring device

    International Nuclear Information System (INIS)

    Joffe, B.B.; Sawyer, B.E.; Spongr, J.J.

    1984-01-01

    A device especially adapted for measuring the thickness of coatings on small, complexly-shaped parts, such as, for example, electronic connectors, electronic contacts, or the like. The device includes a source of beta radiation and a radiation detector whereby backscatter of the radiation from the coated part can be detected and the thickness of the coating ascertained. The radiation source and detector are positioned in overlying relationship to the coated part and a microscope is provided to accurately position the device with respect to the part. Means are provided to control the rate of descent of the radiation source and radiation detector from its suspended position to its operating position and the resulting impact it makes with the coated part to thereby promote uniformity of readings from operator to operator, and also to avoid excessive impact with the part, thereby improving accuracy of measurement and eliminating damage to the parts

  6. Inducer Hydrodynamic Load Measurement Devices

    Science.gov (United States)

    Skelley, Stephen E.; Zoladz, Thomas F.

    2002-01-01

    Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

  7. Improvements in backscatter measurement devices

    International Nuclear Information System (INIS)

    Saunders, J.; Hay, W.D.

    1978-01-01

    Improvements in measuring the thickness of a coating on a substrate by the technique of backscattered particles are described. These improvements enable the measurements to be carried out continuously as an integral part of the coating production line and also permit measurements where the coated elements are separated from one another by a predetermined distance. The former is achieved by situating the backscatter probe and detector on the rim of the measurement wheel and rotating this wheel at a speed such that the coated element and probe are stationary relative to one another. The latter improvement is achieved by an indexing apparatus which automatically positions the probe beside a coated element. (U.K.)

  8. Measurement-Device-Independent Approach to Entanglement Measures

    Science.gov (United States)

    Shahandeh, Farid; Hall, Michael J. W.; Ralph, Timothy C.

    2017-04-01

    Within the context of semiquantum nonlocal games, the trust can be removed from the measurement devices in an entanglement-detection procedure. Here, we show that a similar approach can be taken to quantify the amount of entanglement. To be specific, first, we show that in this context, a small subset of semiquantum nonlocal games is necessary and sufficient for entanglement detection in the local operations and classical communication paradigm. Second, we prove that the maximum payoff for these games is a universal measure of entanglement which is convex and continuous. Third, we show that for the quantification of negative-partial-transpose entanglement, this subset can be further reduced down to a single arbitrary element. Importantly, our measure is measurement device independent by construction and operationally accessible. Finally, our approach straightforwardly extends to quantify the entanglement within any partitioning of multipartite quantum states.

  9. 49 CFR 236.825 - System, automatic train control.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false System, automatic train control. 236.825 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.825 System, automatic train control. A system so arranged that its operation will automatically...

  10. Radiometric densimeter for measuring and automatic control of liquid density

    International Nuclear Information System (INIS)

    Wajs, J.

    1982-01-01

    A performance rule of the radiometric densimeter produced by ''POLON ''Works is presented. A simplified analysis of the correction of density indication changes due to liquid temperature variations is described. A method of replacing the measuring pipe carrying the liquid being measured by suitable standards is given. The method is for automatic systems control. (A.S.)

  11. Device for closing the radioactive sources shutters

    International Nuclear Information System (INIS)

    Teixeira, Everaldo; Santos, Enderson Silvino; Vieira, Carlaine M.; Torquato, Nivaldo Reis; Santos, Evando Ramalho; Castro, Luciano Sampaio

    2002-01-01

    A device for nuclear measurement used at the industrial installation is composed of a radioactive source (Cs 137), the ionization or scintillation chamber and the circuitry parts. The ionization and scintillation chambers are mounted at the industrial piping and monitoring the density of the material inside the piping, based on radiation quantity which comes to receiving chamber. This information is sending to the electronic unity which is responsible for the calculations and remote and local indications of the measured density. Based on the recommendation of the radioactive sources must have the shutters closed when they are inactive, an automatic device composed by solenoid valve, a support and a mechanical shaft which when connected to the supervisory system (CLP's) cause the automatic closing of the shutter of the radioactive sources during the shutting down of the process

  12. Quantitative Analysis of Heavy Metals in Water Based on LIBS with an Automatic Device for Sample Preparation

    International Nuclear Information System (INIS)

    Hu Li; Zhao Nanjing; Liu Wenqing; Meng Deshuo; Fang Li; Wang Yin; Yu Yang; Ma Mingjun

    2015-01-01

    Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. (paper)

  13. Automatic Recognition Method for Optical Measuring Instruments Based on Machine Vision

    Institute of Scientific and Technical Information of China (English)

    SONG Le; LIN Yuchi; HAO Liguo

    2008-01-01

    Based on a comprehensive study of various algorithms, the automatic recognition of traditional ocular optical measuring instruments is realized. Taking a universal tools microscope (UTM) lens view image as an example, a 2-layer automatic recognition model for data reading is established after adopting a series of pre-processing algorithms. This model is an optimal combination of the correlation-based template matching method and a concurrent back propagation (BP) neural network. Multiple complementary feature extraction is used in generating the eigenvectors of the concurrent network. In order to improve fault-tolerance capacity, rotation invariant features based on Zernike moments are extracted from digit characters and a 4-dimensional group of the outline features is also obtained. Moreover, the operating time and reading accuracy can be adjusted dynamically by setting the threshold value. The experimental result indicates that the newly developed algorithm has optimal recognition precision and working speed. The average reading ratio can achieve 97.23%. The recognition method can automatically obtain the results of optical measuring instruments rapidly and stably without modifying their original structure, which meets the application requirements.

  14. Application of β plastic film thickness gauge in automatic production of agricultural film

    International Nuclear Information System (INIS)

    Liu Longzhi; Guo Juhao

    1996-01-01

    The author briefly explains the importance of agricultural film at home, and mainly explains the measuring principles of plastic film thickness, the design of β detector, the temperature compensation technology and the design of automatic control device

  15. Device for automatic filter changing. Einrichtung zum selbsttaetigen Wechseln eines Filters

    Energy Technology Data Exchange (ETDEWEB)

    Matschoss, V; Naschwitz, A; Wild, H

    1984-01-05

    A filter is moved from a store to an aerosol pipe by a lifting device and is clamped there. At the end of the operating period, the lifting device moves a new filter to a parking place. Control is from limit switches of the lifting, clamping and thrust devices and the position control of the store is by the limit switches. The filter changing device is enclosed in a gastight case, prevents blockage of a filter and makes it possible to set a certain operating period, to change the filter without interrupting the aerosol flow and to measure each filter in the sequence of operation outside the aerosol flow.

  16. Device for the analysis of fine dusts

    International Nuclear Information System (INIS)

    Riemer, F.; Tausch, W.; Torge, R.

    1978-01-01

    The invention deals with a device that brings graphite bulbs containing samples of fine dusts automatically to the spectrometer for analysis and transports them away afterwards, a great number of individual measurements thus being quickly performed. The device consists of magazines, means of transport for them etc., and, if necessary, also a furnace for thermal preparation of the samples. (RW) 891 RW/RW 892 MKO [de

  17. 10 CFR Appendix J1 to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Automatic and Semi-Automatic Clothes...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Energy Consumption of Automatic and Semi-Automatic Clothes Washers The provisions of this appendix J1... means for determining the energy consumption of a clothes washer with an adaptive control system...

  18. An automatic device for sample insertion and extraction to/from reactor irradiation facilities

    International Nuclear Information System (INIS)

    Alloni, L.; Venturelli, A.; Meloni, S.

    1990-01-01

    At the previous European Triga Users Conference in Vienna,a paper was given describing a new handling tool for irradiated samples at the L.E.N.A plant. This tool was the first part of an automatic device for the management of samples to be irradiated in the TRIGA MARK ii reactor and successively extracted and stored. So far sample insertion and extraction to/from irradiation facilities available on reactor top (central thimble,rotatory specimen rack and channel f),has been carried out manually by reactor and health-physics operators using the ''traditional'' fishing pole provided by General Atomic, thus exposing reactor personnel to ''unjustified'' radiation doses. The present paper describes the design and the operation of a new device, a ''robot''type machine,which, remotely operated, takes care of sample insertion into the different irradiation facilities,sample extraction after irradiation and connection to the storage pits already described. The extraction of irradiated sample does not require the presence of reactor personnel on the reactor top and,therefore,radiation doses are strongly reduced. All work from design to construction has been carried out by the personnel of the electronic group of the L.E.N.A plant. (orig.)

  19. Design of an automatic sample changer for the measurement of neutron flux by gamma spectrometry

    International Nuclear Information System (INIS)

    Gago, Javier; Bruna, Ruben; Baltuano, Oscar; Montoya, Eduardo; Descreaux, Killian

    2014-01-01

    This paper presents calculus, selection and components design for the construction of an automatic system in order to measure neutron flux in a working nuclear reactor by the gamma spectrometry technique using samples irradiated on the RP-10 nucleus. This system will perform the measurement of interchanging 100 samples in a programed and automatic way, reducing operation time by the user and obtaining more accurate measures. (authors).

  20. Multichannel display system with automatic sequential output of analog data

    International Nuclear Information System (INIS)

    Bykovskii, Yu.A.; Gruzinov, A.E.; Lagoda, V.B.

    1989-01-01

    The authors describe a device that, with maximum simplicity and autonomy, permits parallel data display from 16 measuring channels with automatic output to the screen of a storage oscilloscope in ∼ 50 μsec. The described device can be used to study the divergence characteristics of the ion component of plasma sources and in optical and x-ray spectroscopy of pulsed processes. Owing to its compactness and autonomy, the device can be located in the immediate vicinity of the detectors (for example, inside a vacuum chamber), which allows the number of vacuum electrical lead-ins and the induction level to be reduced

  1. MATHEMATICAL MODELING OF THE UNPUT DEVICES IN AUTOMATIC LOCOMOTIVE SIGNALING SYSTEM

    Directory of Open Access Journals (Sweden)

    O. O. Gololobova

    2014-03-01

    Full Text Available Purpose. To examine the operation of the automatic locomotive signaling system (ALS, to find out the influence of external factors on the devices operation and the quality of the code information derived from track circuit information, as well as to enable modeling of failure occurrences that may appear during operation. Methodology. To achieve this purpose, the main obstacles in ALS operation and the reasons for their occurrence were considered and the system structure principle was researched. The mathematical model for input equipment of the continuous automatic locomotive signaling system (ALS with the number coding was developed. It was designed taking into account all the types of code signals “R”, “Y”, “RY” and equivalent scheme of replacing the filter with a frequency of 50 Hz. Findings. The operation of ALSN with a signal current frequency of 50 Hz was examined. The adequate mathematical model of input equipment of ALS with a frequency of 50 Hz was developed. Originality. The computer model of input equipment of ALS system in the environment of MATLAB+Simulink was developed. The results of the computer modeling on the outlet of the filter during delivering every type of code combination were given in the article. Practical value. With the use of developed mathematical model of ALS system operation we have an opportunity to study, research and determine behavior of the circuit during the normal operation mode and failure occurrences. Also there is a possibility to develop and apply different scheme decisions in modeling environment MATLAB+Simulink for reducing the influence of obstacles on the functional capability of ALS and to model the occurrence of possible difficulties.

  2. Automatic HTS force measurement instrument

    International Nuclear Information System (INIS)

    Sanders, S.T.; Niemann, R.C.

    1999-01-01

    A device is disclosed for measuring the levitation force of a high temperature superconductor sample with respect to a reference magnet includes a receptacle for holding several high temperature superconductor samples each cooled to superconducting temperature. A rotatable carousel successively locates a selected one of the high temperature superconductor samples in registry with the reference magnet. Mechanism varies the distance between one of the high temperature superconductor samples and the reference magnet, and a sensor measures levitation force of the sample as a function of the distance between the reference magnet and the sample. A method is also disclosed. 3 figs

  3. Semi-automatic characterization and simulation of VCSEL devices for high speed VSR communications

    Science.gov (United States)

    Pellevrault, S.; Toffano, Z.; Destrez, A.; Pez, M.; Quentel, F.

    2006-04-01

    Very short range (VSR) high bit rate optical fiber communications are an emerging market dedicated to local area networks, digital displays or board to board interconnects within real time calculators. In this technology, a very fast way to exchange data with high noise immunity and low-cost is needed. Optical multimode graded index fibers are used here because they have electrical noise immunity and are easier to handle than monomode fibers. 850 nm VCSEL are used in VSR communications because of their low cost, direct on-wafer tests, and the possibility of manufacturing VCSEL arrays very easily compared to classical optical transceivers using edge-emitting laser diodes. Although much research has been carried out in temperature modeling on VCSEL emitters, few studies have been devoted to characterizations over a very broad range of temperatures. Nowadays, VCSEL VSR communications tend to be used in severe environments such as space, avionics and military equipments. Therefore, a simple way to characterize VCSEL emitters over a broad range of temperature is required. In this paper, we propose a complete characterization of the emitter part of 2.5 Gb/s opto-electrical transceiver modules operating from -40°C to +120°C using 850 nm VCSELs. Our method uses simple and semi-automatic measurements of a given set of chosen device parameters in order to make fast and efficient simulations.

  4. USING AFFORDABLE DATA CAPTURING DEVICES FOR AUTOMATIC 3D CITY MODELLING

    Directory of Open Access Journals (Sweden)

    B. Alizadehashrafi

    2017-11-01

    Full Text Available In this research project, many movies from UTM Kolej 9, Skudai, Johor Bahru (See Figure 1 were taken by AR. Drone 2. Since the AR drone 2.0 has liquid lens, while flying there were significant distortions and deformations on the converted pictures of the movies. Passive remote sensing (RS applications based on image matching and Epipolar lines such as Agisoft PhotoScan have been tested to create the point clouds and mesh along with 3D models and textures. As the result was not acceptable (See Figure 2, the previous Dynamic Pulse Function based on Ruby programming language were enhanced and utilized to create the 3D models automatically in LoD3. The accuracy of the final 3D model is almost 10 to 20 cm. After rectification and parallel projection of the photos based on some tie points and targets, all the parameters were measured and utilized as an input to the system to create the 3D model automatically in LoD3 in a very high accuracy.

  5. Using Affordable Data Capturing Devices for Automatic 3d City Modelling

    Science.gov (United States)

    Alizadehashrafi, B.; Abdul-Rahman, A.

    2017-11-01

    In this research project, many movies from UTM Kolej 9, Skudai, Johor Bahru (See Figure 1) were taken by AR. Drone 2. Since the AR drone 2.0 has liquid lens, while flying there were significant distortions and deformations on the converted pictures of the movies. Passive remote sensing (RS) applications based on image matching and Epipolar lines such as Agisoft PhotoScan have been tested to create the point clouds and mesh along with 3D models and textures. As the result was not acceptable (See Figure 2), the previous Dynamic Pulse Function based on Ruby programming language were enhanced and utilized to create the 3D models automatically in LoD3. The accuracy of the final 3D model is almost 10 to 20 cm. After rectification and parallel projection of the photos based on some tie points and targets, all the parameters were measured and utilized as an input to the system to create the 3D model automatically in LoD3 in a very high accuracy.

  6. Scan-Less Line Field Optical Coherence Tomography, with Automatic Image Segmentation, as a Measurement Tool for Automotive Coatings

    Directory of Open Access Journals (Sweden)

    Samuel Lawman

    2017-04-01

    Full Text Available The measurement of the thicknesses of layers is important for the quality assurance of industrial coating systems. Current measurement techniques only provide a limited amount of information. Here, we show that spectral domain Line Field (LF Optical Coherence Tomography (OCT is able to return to the user a cross sectional B-Scan image in a single shot with no mechanical moving parts. To reliably extract layer thicknesses from such images of automotive paint systems, we present an automatic graph search image segmentation algorithm. To show that the algorithm works independently of the OCT device, the measurements are repeated with a separate time domain Full Field (FF OCT system. This gives matching mean thickness values within the standard deviations of the measured thicknesses across each B-Scan image. The combination of an LF-OCT with graph search segmentation is potentially a powerful technique for the quality assurance of non-opaque industrial coating layers.

  7. System for automatic x-ray-image analysis, measurement, and sorting of laser fusion targets

    International Nuclear Information System (INIS)

    Singleton, R.M.; Perkins, D.E.; Willenborg, D.L.

    1980-01-01

    This paper describes the Automatic X-Ray Image Analysis and Sorting (AXIAS) system which is designed to analyze and measure x-ray images of opaque hollow microspheres used as laser fusion targets. The x-ray images are first recorded on a high resolution film plate. The AXIAS system then digitizes and processes the images to accurately measure the target parameters and defects. The primary goals of the AXIAS system are: to provide extremely accurate and rapid measurements, to engineer a practical system for a routine production environment and to furnish the capability of automatically measuring an array of images for sorting and selection

  8. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

    Science.gov (United States)

    Huang, Hsin-Chia Carol; Hillman, David R; McArdle, Nigel

    2012-09-01

    To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Tertiary sleep clinic. There were 190 consecutive patients with OSA referred for APAP titration. There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices.

  9. Automatic measurement system for congenital hip dislocation using a computed radiography

    International Nuclear Information System (INIS)

    Komori, M.; Minato, K.; Hirakawa, A.; Kuwahara, M.

    1988-01-01

    Acetabular angle which is a diagnostic parameter of congenital hip dislocation has been measured manually in conventional X-ray film system. Using digital image directly provided from a computed radiography, an automatic measurement system was developed for this parameter. The process of the measurement was completed within a reasonable time, and accurate enough. The system was combined with an image database, so that it would be a measurement tool of PACS

  10. Fixed type incore measuring device

    International Nuclear Information System (INIS)

    Oda, Naotaka; Ito, Hitoshi; Maeda, Hiroyuki

    1998-01-01

    The present invention concerns a measuring device using gamma thermometers to be used in a BWR type reactor. An input switch is inserted to the vicinity of a detection signal input portion of a signal cable connecting GT with the detection signal input portion of a fixed type incore measuring device, and a loop resistance measuring means is disposed to the input switch on the side of the GT by way of a measurement switch. Upon measuring loop resistance, the GT measuring circuit is switched from the detection signal input portion to the loop resistance measuring means by a switching operation of the input switch and the measurement switch thereby enabling to confirm the value of the loop resistance. In addition, the lowering of the voltage in the loop resistance is compensated to confirm the accurate measurement values to be used thereby enabling to measure GT detection signals accurately. A diagnosing means for diagnosing the state of GT based on the results of the measurement for the loop resistance is disposed, and the results are reported to an operator. (N.H.)

  11. Comparison of manual and semi-automatic measuring techniques in MSCT scans of patients with lymphoma: a multicentre study

    Energy Technology Data Exchange (ETDEWEB)

    Hoeink, A.J.; Wessling, J.; Schuelke, C.; Kohlhase, N.; Wassenaar, L.; Heindel, W.; Buerke, B. [University Hospital Muenster, Department of Clinical Radiology, Muenster (Germany); Koch, R. [University of Muenster, Institute of Biostatistics and Clinical Research (IBKF), Muenster (Germany); Mesters, R.M. [University Hospital Muenster, Department of Haematology and Oncology, Muenster (Germany); D' Anastasi, M.; Graser, A.; Karpitschka, M. [University Hospital Muenchen (LMU), Institute of Clinical Radiology, Muenchen (Germany); Fabel, M.; Wulff, A. [University Hospital Kiel, Department of Clinical Radiology, Kiel (Germany); Pinto dos Santos, D. [University Hospital Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Kiessling, A. [University Hospital Marburg, Department of Diagnostic and Interventional Radiology, Marburg (Germany); Dicken, V.; Bornemann, L. [Institute of Medical Imaging Computing, Fraunhofer MeVis, Bremen (Germany)

    2014-11-15

    Multicentre evaluation of the precision of semi-automatic 2D/3D measurements in comparison to manual, linear measurements of lymph nodes regarding their inter-observer variability in multi-slice CT (MSCT) of patients with lymphoma. MSCT data of 63 patients were interpreted before and after chemotherapy by one/tworadiologists in five university hospitals. In 307 lymph nodes, short (SAD)/long (LAD) axis diameter and WHO area were determined manually and semi-automatically. Volume was solely calculated semi-automatically. To determine the precision of the individual parameters, a mean was calculated for every lymph node/parameter. Deviation of the measured parameters from this mean was evaluated separately. Statistical analysis entailed intraclass correlation coefficients (ICC) and Kruskal-Wallis tests. Median relative deviations of semi-automatic parameters were smaller than deviations of manually assessed parameters, e.g. semi-automatic SAD 5.3 vs. manual 6.5 %. Median variations among different study sites were smaller if the measurement was conducted semi-automatically, e. g. manual LAD 5.7/4.2 % vs. semi-automatic 3.4/3.4 %. Semi-automatic volumetry was superior to the other parameters (2.8 %). Semi-automatic determination of different lymph node parameters is (compared to manually assessed parameters) associated with a slightly greater precision and a marginally lower inter-observer variability. These results are with regard to the increasing mobility of patients among different medical centres and in relation to the quality management of multicentre trials of importance. (orig.)

  12. Automatic particle-size analysis of HTGR nuclear fuel microspheres

    International Nuclear Information System (INIS)

    Mack, J.E.

    1977-01-01

    An automatic particle-size analyzer (PSA) has been developed at ORNL for measuring and counting samples of nuclear fuel microspheres in the diameter range of 300 to 1000 μm at rates in excess of 2000 particles per minute, requiring no sample preparation. A light blockage technique is used in conjunction with a particle singularizer. Each particle in the sample is sized, and the information is accumulated by a multi-channel pulse height analyzer. The data are then transferred automatically to a computer for calculation of mean diameter, standard deviation, kurtosis, and skewness of the distribution. Entering the sample weight and pre-coating data permits calculation of particle density and the mean coating thickness and density. Following this nondestructive analysis, the sample is collected and returned to the process line or used for further analysis. The device has potential as an on-line quality control device in processes dealing with spherical or near-spherical particles where rapid analysis is required for process control

  13. Diffraction phase microscopy realized with an automatic digital pinhole

    Science.gov (United States)

    Zheng, Cheng; Zhou, Renjie; Kuang, Cuifang; Zhao, Guangyuan; Zhang, Zhimin; Liu, Xu

    2017-12-01

    We report a novel approach to diffraction phase microscopy (DPM) with automatic pinhole alignment. The pinhole, which serves as a spatial low-pass filter to generate a uniform reference beam, is made out of a liquid crystal display (LCD) device that allows for electrical control. We have made DPM more accessible to users, while maintaining high phase measurement sensitivity and accuracy, through exploring low cost optical components and replacing the tedious pinhole alignment process with an automatic pinhole optical alignment procedure. Due to its flexibility in modifying the size and shape, this LCD device serves as a universal filter, requiring no future replacement. Moreover, a graphic user interface for real-time phase imaging has been also developed by using a USB CMOS camera. Experimental results of height maps of beads sample and live red blood cells (RBCs) dynamics are also presented, making this system ready for broad adaption to biological imaging and material metrology.

  14. SU-F-P-36: Automation of Linear Accelerator Star Shot Measurement with Advanced XML Scripting and Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Nguyen, N; Knutson, N; Schmidt, M; Price, M

    2016-01-01

    Purpose: To verify a method used to automatically acquire jaw, MLC, collimator and couch star shots for a Varian TrueBeam linear accelerator utilizing Developer Mode and an Electronic Portal Imaging Device (EPID). Methods: An XML script was written to automate motion of the jaws, MLC, collimator and couch in TrueBeam Developer Mode (TBDM) to acquire star shot measurements. The XML script also dictates MV imaging parameters to facilitate automatic acquisition and recording of integrated EPID images. Since couch star shot measurements cannot be acquired using a combination of EPID and jaw/MLC collimation alone due to a fixed imager geometry, a method utilizing a 5mm wide steel ruler placed on the table and centered within a 15×15cm2 open field to produce a surrogate of the narrow field aperture was investigated. Four individual star shot measurements (X jaw, Y jaw, MLC and couch) were obtained using our proposed as well as traditional film-based method. Integrated EPID images and scanned measurement films were analyzed and compared. Results: Star shot (X jaw, Y jaw, MLC and couch) measurements were obtained in a single 5 minute delivery using the TBDM XML script method compared to 60 minutes for equivalent traditional film measurements. Analysis of the images and films demonstrated comparable isocentricity results, agreeing within 0.3mm of each other. Conclusion: The presented automatic approach of acquiring star shot measurements using TBDM and EPID has proven to be more efficient than the traditional film approach with equivalent results.

  15. Automatic measurement of target crossing speed

    Science.gov (United States)

    Wardell, Mark; Lougheed, James H.

    1992-11-01

    The motion of ground vehicle targets after a ballistic round is launched can be a major source of inaccuracy for small (handheld) anti-armour weapon systems. A method of automatically measuring the crossing component to compensate the fire control solution has been devised and tested against various targets in a range of environments. A photodetector array aligned with the sight's horizontal reticle obtains scene features, which are digitized and processed to separate target from sight motion. Relative motion of the target against the background is briefly monitored to deduce angular crossing rate and a compensating lead angle is introduced into the aim point. Research to gather quantitative data and optimize algorithm performance is described, and some results from field testing are presented.

  16. Equipment for fully automatic radiographic pipe inspection

    International Nuclear Information System (INIS)

    Basler, G.; Sperl, H.; Weinschenk, K.

    1977-01-01

    The patent describes a device for fully automatic radiographic testing of large pipes with longitudinal welds. Furthermore the invention enables automatic marking of films in radiographic inspection with regard to a ticketing of the test piece and of that part of it where testing took place. (RW) [de

  17. Comparison of Efficacy and Tolerance of Automatic Continuous Positive Airway Pressure Devices With the Optimum Continuous Positive Airway Pressure.

    Science.gov (United States)

    Tommi, George; Aronow, Wilbert S; Sheehan, John C; McCleay, Matthew T; Meyers, Patrick G

    Patients diagnosed with obstructive sleep apnea syndrome were randomly placed on automatic continuous positive airway pressure (ACPAP) for 2 hours followed by manual titration for the rest of the night. One hundred sixty-one patients entered the study, with at least 50 patients titrated with each of 3 ACPAP devices. The optimum continuous positive airway pressure (CPAP) was defined as the lowest pressure with an apnea-hypoxia index of ≤5/hr, which ranged from 4 cm to 18 cm. Success with ACPAP was approximately 60%-80% when the optimum CPAP was 4-6 cm but fell to below 30% if the optimum CPAP was ≥8 cm (P = 0.001). Average ACPAP ranged from 2 to 10 cm below the optimum level if the optimum CPAP was ≥8 cm. Patients who responded to a low CPAP but deteriorated on higher pressures failed to respond to any of the automatic devices. We recommend that CPAP titration be performed manually before initiation of ACPAP in patients with obstructive sleep apnea. The basal pressure for ACPAP should be the optimum pressure obtained by manual titration. Limits on the upper level of ACPAP may be necessary for patients who deteriorate on higher positive pressures.

  18. Method and device for measuring fluid flow

    International Nuclear Information System (INIS)

    Atherton, R.; Marinkovich, P.S.; Spadaro, P.R.; Stout, J.W.

    1976-01-01

    The invention is a fluid flow measuring device for determining the coolant flow at the entrance to a specific nuclear reactor fuel region. The device comprises a plurality of venturis having the upstream inlet and throat pressure of each respectively manifolded together to provide one static pressure signal for each region monitored. The device provides accurate flow measurement with low pressure losses and uniform entrance and discharge flow distribution. 1 claim, 7 figures

  19. Automatic particle-size analysis of HTGR recycle fuel

    International Nuclear Information System (INIS)

    Mack, J.E.; Pechin, W.H.

    1977-09-01

    An automatic particle-size analyzer was designed, fabricated, tested, and put into operation measuring and counting HTGR recycle fuel particles. The particle-size analyzer can be used for particles in all stages of fabrication, from the loaded, uncarbonized weak acid resin up to fully-coated Biso or Triso particles. The device handles microspheres in the range of 300 to 1000 μm at rates up to 2000 per minute, measuring the diameter of each particle to determine the size distribution of the sample, and simultaneously determining the total number of particles. 10 figures

  20. ALS insertion device block measurement and inspection

    International Nuclear Information System (INIS)

    Marks, S.; Carrieri, J.; Cook, C.; Hassenzahl, W.V.; Hoyer, E.; Plate, D.

    1991-05-01

    The performance specifications for ALS insertion devices require detailed knowledge and strict control of the Nd-Fe-B permanent magnet blocks incorporated in these devices. This paper describes the measurement and inspection apparatus and the procedures designed to qualify and characterize these blocks. A detailed description of a new, automated Helmholtz coil facility for measurement of the three components of magnetic moment is included. Physical block inspection and magnetic moment measurement procedures are described. Together they provide a basis for qualifying blocks and for specifying placement of blocks within an insertion devices' magnetic structures. 1 ref., 4 figs

  1. Digital Thickness Measurement of a Transparent Plastic Orthodontic Device

    Science.gov (United States)

    Kim, Yoon-Hwan; Rhim, Sung-Han

    2018-05-01

    A transparent orthodontic device is used to move the teeth to the final calibration position to form a proper set of teeth. Because the uniform thickness of the device plays an important role in tooth positioning, the accuracy of the device's thickness profile is important for effective orthodontic treatment. However, due to the complexity of the device's geometry and the transparency of the device's material, measuring the complete thickness profile has been difficult. In the present study, a new optical scanning method to measure the thickness profile of transparent plastic orthodontic devices is proposed and evaluated by using scanning electron microscopy (SEM). The error of the new measurement method is less than ±18 μm. The new method can be used to measure the thickness of non-specific, multi-curved, transparent orthodontic devices.

  2. Automatic shading effects on the energetic performance of building systems; Efeito do sombreamento automatico no desempenho de sistemas prediais

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Racine Tadeu Araujo

    1997-12-31

    This thesis develops a theoretic-experimental study dealing with the effects of an automatic shading device on the energetic performance of a dimmable lighting system and a cooling equipment. Some equations related to fenestration optical and thermal properties are rebuilt, while some others are created, under a theoretical approach. In order to collect field data, the energy demand-and other variables - was measured in two distinct stories, with the same fenestration features, of the Test Tower. New data was gathered after adding an automatic shading device to the window of one story. The comparison of the collected data allows the energetic performance evaluation of the shading device. (author) 136 refs., 55 figs., 6 tabs.

  3. Automatic shading effects on the energetic performance of building systems; Efeito do sombreamento automatico no desempenho de sistemas prediais

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Racine Tadeu Araujo

    1996-12-31

    This thesis develops a theoretic-experimental study dealing with the effects of an automatic shading device on the energetic performance of a dimmable lighting system and a cooling equipment. Some equations related to fenestration optical and thermal properties are rebuilt, while some others are created, under a theoretical approach. In order to collect field data, the energy demand-and other variables - was measured in two distinct stories, with the same fenestration features, of the Test Tower. New data was gathered after adding an automatic shading device to the window of one story. The comparison of the collected data allows the energetic performance evaluation of the shading device. (author) 136 refs., 55 figs., 6 tabs.

  4. Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension

    Directory of Open Access Journals (Sweden)

    Asmar R

    2011-11-01

    Full Text Available Jirar Topouchian1, Davide Agnoletti1, Jacques Blacher1, Ahmed Youssef1, Isabel Ibanez2,3, Jose Khabouth2, Salwa Khawaja2, Layale Beaino2, Roland Asmar1–31Centre de Diagnostic, Hôpital Hôtel-Dieu, Paris, France; 2Hôpital Libanais and Faculté Libanaise de Médecine, Beirut, Lebanon; 3Foundation-Medical Research Institutes, Geneva, SwitzerlandBackground: Four oscillometric devices for self-measurement of blood pressure (SBPM were evaluated according to the European Society of Hypertension (ESH international protocol and its 2010 revision in four separate studies. The Omron® M2, Omron M3, and Omron M6 measure blood pressure (BP at the brachial level, while the Omron R2 measures BP at the wrist level.Methods: The international protocol requires a total number of 33 subjects in which the validation is performed. The Omron M2 and Omron R2 were validated in 2009 according to the ESH international protocol, while the Omron M3 and Omron M6 were validated in 2010–2011 according to the 2010 ESH international protocol revision. The protocol procedures were followed precisely.Results: All four tested devices passed the validation process. The mean differences between the device and mercury readings were 2.7 ± 5.0 and –1.4 ± 3.2 mmHg for systolic and diastolic BP, respectively, using the Omron M2 device, and 1.7 ± 3.2 and –0.9 ± 2.6 mmHg using the Omron M3, 1.6 ± 2.9 and -0.9 ± 2.5 mmHg using the Omron M6, and –1.1 ± 4.8 and –0.9 ± 4.3 mmHg using the Omron R2.Conclusion: Readings from the Omron M2, Omron M3, Omron M6, and Omron R2, differing by less than 5, 10, and 15 mmHg, fulfill the ESH international protocol and its 2010 revision requirements. Therefore, each of these four devices can be used by patients for SBPM.Keywords: Omron R2, M2, M3, M6, blood pressure measurement, validation, international protocol, European Society of Hypertension

  5. Automatic measuring system of zirconium thickness for zirconium liner cladding tubes

    International Nuclear Information System (INIS)

    Matsui, K.; Yamaguchi, H.; Hiroshima, T.; Sakamoto, T.; Murayama, R.

    1985-01-01

    An automatic system of pure zirconium liner thickness for zirconium-zircaloy cladding tubes has been successfully developed. The system consists of three parts. (1) An ultrasonic thickness measuring method for mother tubes before cold rolling. (2) An electromagnetic thickness measuring method for the manufactured tubes. (3) An image processing method for the cross sectional view of the manufactured cut tube samples. In Japanese nuclear industry, zirconium-zircaloy cladding tubes have been tested in order to realize load following operation in the atomic power plant. In order to provide for the practical use in the near future, Sumitomo Metal Industries, Ltd. has been studied and established the practical manufacturing process of the zirconium liner cladding tubes. The zirconium-liner cladding tube is a duplex tube comprising an inner layer of pure zirconium bonded to zircaloy metallurgically. The thickness of the pure zirconium is about 10 % of the total wall thickness. Several types of the automatic thickness measuring methods have been investigated instead of the usual microscopic viewing method in which the liner thickness is measured by the microscopic cross sectional view of the cut tube samples

  6. Automatization of the radiation control measurements

    International Nuclear Information System (INIS)

    Seki, Akio; Ogata, Harumi; Horikoshi, Yoshinori; Shirai, Kenji

    1988-01-01

    Plutonium Fuel Production Facility (PFPF) was constructed to fabricate the MOX fuels for 'MONJU' and 'JOYO' reactors and to develop the practical fuel fabricating technology. For the fuel fabrication process in this facility, centralized controlling system is being adopted for the mass production of the fuel and reduction of the radiation exposure dose. Also, the radiation control systems are suitable for the large-scale facility and the automatic-remote process of the fuel fabrication. One of the typical radiation control systems is the self moving survey system which has been developed by PNC and adopted for the automatic routine monitoring. (author)

  7. Programs for the automatic gamma-ray measurement with CANBERRA 8100/QUANTA system

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Sakai, Eiji; Kubo, Katsumi.

    1982-07-01

    Some programs have been prepared for the automatic operation of the CANBERRA 8100/QUANTA System for the gamma-ray spectrum measurement. The main parts of these programs are: (1) to collect and record on magnetic disks the data of gamma-ray spectra automatically, while the recorded data are analyzed to estimate the nuclides which generate photopeaks of spectra and to calculate those concentrations; (2) to draw plotted diagrams of pulse height distributions of gamma-ray spectra data and other data by the additional digital plotter; and etc. (author)

  8. Continuous moisture measurement in metallurgical coke with automatic charge correction

    International Nuclear Information System (INIS)

    Watzke, H.; Mehlhose, D.

    1981-01-01

    A process control system has been developed for automatic batching of the coke amount necessary for metallurgical processes taking into account the moisture content. The measurement is performed with a neutron moisture gage consisting of an Am-Be neutron source and a BF 3 counter. The output information of the counter is used for computer-controlled batching

  9. Temperature measuring device

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, R.J.; Bible, D.W.; Sohns, C.W.

    1999-10-19

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.

  10. Automatic high-sensitivity control of suspended pollutants in drinking and natural water

    Science.gov (United States)

    Akopov, Edmund I.; Karabegov, M.; Ovanesyan, A.

    1993-11-01

    This article presents a description of the new instrumental method and device for automatic measurement of water turbidity (WT) by means of photoelectron flow ultramicroscope (PFU). The method presents the WT determination by measuring the number concentration (number of particles suspended in 1 cm3 of water under study) using the PFU and demonstrates much higher sensitivity and accuracy in comparison with the usual methods--turbidimetry and nephelometry.

  11. [Development of an automatic vacuum liquid chromatographic device and its application in the separation of the components from Schisandra chinensis (Turz) Baill].

    Science.gov (United States)

    Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei

    2015-08-01

    In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines.

  12. Automatic sleep scoring: a search for an optimal combination of measures.

    Science.gov (United States)

    Krakovská, Anna; Mezeiová, Kristína

    2011-09-01

    The objective of this study is to find the best set of characteristics of polysomnographic signals for the automatic classification of sleep stages. A selection was made from 74 measures, including linear spectral measures, interdependency measures, and nonlinear measures of complexity that were computed for the all-night polysomnographic recordings of 20 healthy subjects. The adopted multidimensional analysis involved quadratic discriminant analysis, forward selection procedure, and selection by the best subset procedure. Two situations were considered: the use of four polysomnographic signals (EEG, EMG, EOG, and ECG) and the use of the EEG alone. For the given database, the best automatic sleep classifier achieved approximately an 81% agreement with the hypnograms of experts. The classifier was based on the next 14 features of polysomnographic signals: the ratio of powers in the beta and delta frequency range (EEG, channel C3), the fractal exponent (EMG), the variance (EOG), the absolute power in the sigma 1 band (EEG, C3), the relative power in the delta 2 band (EEG, O2), theta/gamma (EEG, C3), theta/alpha (EEG, O1), sigma/gamma (EEG, C4), the coherence in the delta 1 band (EEG, O1-O2), the entropy (EMG), the absolute theta 2 (EEG, Fp1), theta/alpha (EEG, Fp1), the sigma 2 coherence (EEG, O1-C3), and the zero-crossing rate (ECG); however, even with only four features, we could perform sleep scoring with a 74% accuracy, which is comparable to the inter-rater agreement between two independent specialists. We have shown that 4-14 carefully selected polysomnographic features were sufficient for successful sleep scoring. The efficiency of the corresponding automatic classifiers was verified and conclusively demonstrated on all-night recordings from healthy adults. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Measuring device for the temperature coefficient of reactor moderators

    International Nuclear Information System (INIS)

    Nakano, Yuzo.

    1987-01-01

    Purpose: To rapidly determine by automatic calculation the temperature coefficient for moderators which has been determined so far by a log of manual processings. Constitution: Each of signals from a control rod position indicator, a reactor reactivity, instrument and moderator temperature meter are inputted, and each of the signals and designed valued for the doppler temperature coefficients are stored. Recurling calculation is conducted based on the reactivity and the moderator temperature at an interval where the temperature changes of the moderators are equalized at an identical control rod position, to determine isothermic coefficient. Then, the temperature coefficient for moderator are calculated from the isothermic coefficient and the doppler temperature coefficient. The relationship between the reactivity and the moderator temperature is plotted on a X-Y recorder. The stored signals and the calculated temperature coefficient for moderators are sequentially displayed and the results are printed out when the measurement is completed. According to the present device, since the real time processing is conducted, the processing time can be shortened remarkably. Accordingly, it is possible to save the man power for the test of the nuclear reactor and improve the reactor operation performance. (Kamimura, M.)

  14. The Diagnostic System of A – 604 Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Czaban Jaroslaw

    2014-09-01

    Full Text Available Automatic gearbox gains increasing popularity in Europe. Little interest in diagnosis of such type of transmission in Poland results from the fact of small share in the whole market of operated cars, so there is a lack of availability of special diagnostic devices. These factors cause issues of expensive repairs, often involving a replacement of subassembly to new or aftermarket one. To a small extent some prophylactic diagnostic tests are conducted, which can eliminate future gearbox system failures. In the paper, the proposition of diagnostic system of popular A - 604 gearbox was presented. The authors are seeking for the possibility of using such type of devices to functional elaboration of gearboxes after renovation. The built system pursues the drive of the researched object, connected with simulated load, where special controller, replacing the original one, is responsible for controlling gearbox operation. This way is used to evaluate the mechanic and hydraulic parts' state. Analysis of signal runs, registered during measurements lets conclude about operation correctness, where as comparison with stock data verifies the technical state of an automatic gearbox.

  15. Effect of automatic control technologies on emission reduction in small-scale combustion

    Energy Technology Data Exchange (ETDEWEB)

    Ruusunen, M. [Control Engineering Laboratory, University of Oulu (Finland)

    2007-07-01

    Automatic control can be regarded as a primary measure for preventing combustion emissions. In this view, the control technology covers broadly the control methods, sensors and actuators for monitoring and controlling combustion. In addition to direct control of combustion process, it can also give tools for condition monitoring and optimisation of total heat consumption by system integration thus reducing the need for excess conversion of energy. Automatic control has already shown its potential in small-scale combustion. The potential, but still unrealised advantages of automatic control in this scale are the adaptation to changes in combustion conditions (fuel, environment, device, user) and the continuous optimisation of the air/fuel ratio. Modem control technology also covers combustion condition monitoring, diagnostics, and the higher level optimisation of the energy consumption with system integration. In theory, these primary measures maximise the overall efficiency, enabling a significant reduction in fuel consumption and thus total emissions per small-scale combustion unit, specifically at the annual level.

  16. Automatic welding and cladding in heavy fabrication

    International Nuclear Information System (INIS)

    Altamer, A. de

    1980-01-01

    A description is given of the automatic welding processes used by an Italian fabricator of pressure vessels for petrochemical and nuclear plant. The automatic submerged arc welding, submerged arc strip cladding, pulsed TIG, hot wire TIG and MIG welding processes have proved satisfactory in terms of process reliability, metal deposition rate, and cost effectiveness for low alloy and carbon steels. An example shows sequences required during automatic butt welding, including heat treatments. Factors which govern satisfactory automatic welding include automatic anti-drift rotator device, electrode guidance and bead programming system, the capability of single and dual head operation, flux recovery and slag removal systems, operator environment and controls, maintaining continuity of welding and automatic reverse side grinding. Automatic welding is used for: joining vessel sections; joining tubes to tubeplate; cladding of vessel rings and tubes, dished ends and extruded nozzles; nozzle to shell and butt welds, including narrow gap welding. (author)

  17. Automatic joint alignment measurements from pre- and post-operative long leg standing radiographs

    NARCIS (Netherlands)

    Goossen, A.; Weber, G.M.; Dries, S.P.M.

    2012-01-01

    Objectives: For diagnosis or treatment assessment of knee joint osteoarthritis it is required to measure bone morphometry from radiographic images. We propose a method for automatic measurement of joint alignment from pre-operative as well as post-operative radiographs.Methods: In a two step

  18. Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi

    2016-08-01

    The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.

  19. 21 CFR 864.5950 - Blood volume measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section 864.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  20. The system for automatic dose rate measurements by mobile groups in field

    International Nuclear Information System (INIS)

    Drabova, D.; Filgas, R.; Cespirova, I.; Ejemova, M.

    1998-01-01

    The comparison of characteristics between a pressurized ionization chamber, plastic scintillator and proportional counter is given. Based on requirements and comparison of properties of various probes, the system for automatic dose rate measurement and integration of geographic co-ordinates in field was designed and tested.The system consists of proportional counter. This is so-called intelligent probe can be easily connected to a personal computer. The probe measures in the energy range 30 keV - 1.3 MeV with reasonable energy and angular response, it can measure the dose rate in the range 50 nSv/h - 1 Sv/h with the typical efficiency 9.5 imp/s/μSv/h. The probe is fixed in the holder placed on the front mask of a car. For the simultaneous determination of geographical co-ordinates the personal GPS navigator Garmin 95 is used. Both devices are controlled by a notebook via two serial ports. The second serial port that is not quite common in notebook can be easily realised by a PCMCIA card. The notebook is used in the field by a mobile group can be transmitted to the assessment centre by the cellular GSM phone. The system Nokia 2110 connected to notebook by PCMCIA card is used. The whole system is powered up from the car battery. The system is controlled by specially developed software. The software was developed in the FoxPro 2.5 environment and works under MS-DOS 6.22. It has no problems to work in Windows 95 DOS window. The results of dose rate measurements obtained during route monitoring are stored in files. They can be displayed on a graphic screen, presenting the geographical distribution of the dose rate values colour coded on a map and the time sequence of the measured data. (authors)

  1. The development and application of solid polymer electrolysis enrichment device of tritium in water

    International Nuclear Information System (INIS)

    Wen Xuelian; Yang Hailan Wu Bin; Yang Huaiyuan

    2003-01-01

    This paper briefly describes the working principle of solid polymer electrolysis enrichment device of tritium in water, presents experiments and works in development of SPE tritium automatic electrolysis enrichment device by CIRP, with which the water samples had been processed for TRIC2000, and the measurement results are satisfied

  2. Sensible organizations: technology and methodology for automatically measuring organizational behavior.

    Science.gov (United States)

    Olguin Olguin, Daniel; Waber, Benjamin N; Kim, Taemie; Mohan, Akshay; Ara, Koji; Pentland, Alex

    2009-02-01

    We present the design, implementation, and deployment of a wearable computing platform for measuring and analyzing human behavior in organizational settings. We propose the use of wearable electronic badges capable of automatically measuring the amount of face-to-face interaction, conversational time, physical proximity to other people, and physical activity levels in order to capture individual and collective patterns of behavior. Our goal is to be able to understand how patterns of behavior shape individuals and organizations. By using on-body sensors in large groups of people for extended periods of time in naturalistic settings, we have been able to identify, measure, and quantify social interactions, group behavior, and organizational dynamics. We deployed this wearable computing platform in a group of 22 employees working in a real organization over a period of one month. Using these automatic measurements, we were able to predict employees' self-assessments of job satisfaction and their own perceptions of group interaction quality by combining data collected with our platform and e-mail communication data. In particular, the total amount of communication was predictive of both of these assessments, and betweenness in the social network exhibited a high negative correlation with group interaction satisfaction. We also found that physical proximity and e-mail exchange had a negative correlation of r = -0.55 (p 0.01), which has far-reaching implications for past and future research on social networks.

  3. Reflector automatic acquisition and pointing based on auto-collimation theodolite

    Science.gov (United States)

    Luo, Jun; Wang, Zhiqian; Wen, Zhuoman; Li, Mingzhu; Liu, Shaojin; Shen, Chengwu

    2018-01-01

    An auto-collimation theodolite (ACT) for reflector automatic acquisition and pointing is designed based on the principle of autocollimators and theodolites. First, the principle of auto-collimation and theodolites is reviewed, and then the coaxial ACT structure is developed. Subsequently, the acquisition and pointing strategies for reflector measurements are presented, which first quickly acquires the target over a wide range and then points the laser spot to the charge coupled device zero position. Finally, experiments are conducted to verify the acquisition and pointing performance, including the calibration of the ACT, the comparison of the acquisition mode and pointing mode, and the accuracy measurement in horizontal and vertical directions. In both directions, a measurement accuracy of ±3″ is achieved. The presented ACT is suitable for automatic pointing and monitoring the reflector over a small scanning area and can be used in a wide range of applications such as bridge structure monitoring and cooperative target aiming.

  4. Plasma automatic control in magnetic traps

    International Nuclear Information System (INIS)

    Samojlenko, Yu.I.; Chuyanov, V.A.

    1983-01-01

    Principles of constructing the systems providing a plasma equilibrium and stability in thermonuctear devices are laid down. Operation of the servo system to maintain a plasma equilibrium is described using the tokamak plasma filament as an example. Operation of the system to suppress a flute instability is also described. This system measures electric disturbances on the plasma body surface and controls charge distribution on external electrodes. It is pointed out that systems of automatic control of plasma equilibrium and stability become an essential element of a future thermonuclear reactor and the system potentialities would much determine the reactor economic efficiency

  5. Evaluation of manual and automatic manually triggered ventilation performance and ergonomics using a simulation model.

    Science.gov (United States)

    Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan

    2014-05-01

    In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of

  6. Device to measure elastic modulus of superconducting windings

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    This device was made to measure elastic modulus of the Po dipole superconducting coils. More elaborated devices, but based on the same concept, were later used to measure the apparent elastic moduli of the LHC superconducting magnet coils. See also 7903547X, 7901386.

  7. Response evaluation of malignant liver lesions after TACE/SIRT. Comparison of manual and semi-automatic measurement of different response criteria in multislice CT

    International Nuclear Information System (INIS)

    Hoeink, Anna Janina

    2017-01-01

    To compare measurement precision and interobserver variability in the evaluation of hepatocellular carcinoma (HCC) and liver metastases in MSCT before and after transarterial local ablative therapies. Retrospective study of 72 patients with malignant liver lesions (42 metastases; 30 HCCs) before and after therapy (43 SIRT procedures; 29 TACE procedures). Established (LAD; SAD; WHO) and vitality-based parameters (mRECIST; mLAD; mSAD; EASL) were assessed manually and semi-automatically by two readers. The relative interobserver difference (RID) and intraclass correlation coefficient (ICC) were calculated. The median RID for vitality-based parameters was lower from semi-automatic than from manual measurement of mLAD (manual 12.5 %; semi-automatic 3.4 %), mSAD (manual 12.7 %; semi-automatic 5.7 %) and EASL (manual 10.4 %; semi-automatic 1.8 %). The difference in established parameters was not statistically noticeable (p > 0.05). The ICCs of LAD (manual 0.984; semi-automatic 0.982), SAD (manual 0.975; semi-automatic 0.958) and WHO (manual 0.984; semi-automatic 0.978) are high, both in manual and semi-automatic measurements. The ICCs of manual measurements of mLAD (0.897), mSAD (0.844) and EASL (0.875) are lower. This decrease cannot be found in semi-automatic measurements of mLAD (0.997), mSAD (0.992) and EASL (0.998). Conclusion Vitality-based tumor measurements of HCC and metastases after transarterial local therapies should be performed semi-automatically due to greater measurement precision, thus increasing the reproducibility and in turn the reliability of therapeutic decisions.

  8. Response evaluation of malignant liver lesions after TACE/SIRT. Comparison of manual and semi-automatic measurement of different response criteria in multislice CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoeink, Anna Janina [Univ. Hospital Cologne (Germany). Diagnostic and Interventional Radiology; Schuelke, Christoph; Loehnert, Annika; Kammerer, Sara; Fortkamp, Rasmus; Heindel, Walter; Buerke, Boris [Univ. Hospital Muenster (UKM), Muenster (Germany). Dept. of Clinical Radiology; Koch, Raphael [Univ. Hospital Muenster (UKM), Muenster (Germany). Inst. of Biostatistics and Clinical Research (IBKF)

    2017-11-15

    To compare measurement precision and interobserver variability in the evaluation of hepatocellular carcinoma (HCC) and liver metastases in MSCT before and after transarterial local ablative therapies. Retrospective study of 72 patients with malignant liver lesions (42 metastases; 30 HCCs) before and after therapy (43 SIRT procedures; 29 TACE procedures). Established (LAD; SAD; WHO) and vitality-based parameters (mRECIST; mLAD; mSAD; EASL) were assessed manually and semi-automatically by two readers. The relative interobserver difference (RID) and intraclass correlation coefficient (ICC) were calculated. The median RID for vitality-based parameters was lower from semi-automatic than from manual measurement of mLAD (manual 12.5 %; semi-automatic 3.4 %), mSAD (manual 12.7 %; semi-automatic 5.7 %) and EASL (manual 10.4 %; semi-automatic 1.8 %). The difference in established parameters was not statistically noticeable (p > 0.05). The ICCs of LAD (manual 0.984; semi-automatic 0.982), SAD (manual 0.975; semi-automatic 0.958) and WHO (manual 0.984; semi-automatic 0.978) are high, both in manual and semi-automatic measurements. The ICCs of manual measurements of mLAD (0.897), mSAD (0.844) and EASL (0.875) are lower. This decrease cannot be found in semi-automatic measurements of mLAD (0.997), mSAD (0.992) and EASL (0.998). Conclusion Vitality-based tumor measurements of HCC and metastases after transarterial local therapies should be performed semi-automatically due to greater measurement precision, thus increasing the reproducibility and in turn the reliability of therapeutic decisions.

  9. Automatic and strategic measures as predictors of mirror gazing among individuals with body dysmorphic disorder symptoms.

    Science.gov (United States)

    Clerkin, Elise M; Teachman, Bethany A

    2009-08-01

    The current study tests cognitive-behavioral models of body dysmorphic disorder (BDD) by examining the relationship between cognitive biases and correlates of mirror gazing. To provide a more comprehensive picture, we investigated both relatively strategic (i.e., available for conscious introspection) and automatic (i.e., outside conscious control) measures of cognitive biases in a sample with either high (n = 32) or low (n = 31) BDD symptoms. Specifically, we examined the extent that (1) explicit interpretations tied to appearance, as well as (2) automatic associations and (3) strategic evaluations of the importance of attractiveness predict anxiety and avoidance associated with mirror gazing. Results indicated that interpretations tied to appearance uniquely predicted self-reported desire to avoid, whereas strategic evaluations of appearance uniquely predicted peak anxiety associated with mirror gazing, and automatic appearance associations uniquely predicted behavioral avoidance. These results offer considerable support for cognitive models of BDD, and suggest a dissociation between automatic and strategic measures.

  10. Automatic and Strategic Measures as Predictors of Mirror Gazing Among Individuals with Body Dysmorphic Disorder Symptoms

    Science.gov (United States)

    Clerkin, Elise M.; Teachman, Bethany A.

    2011-01-01

    The current study tests cognitive-behavioral models of body dysmorphic disorder (BDD) by examining the relationship between cognitive biases and correlates of mirror gazing. To provide a more comprehensive picture, we investigated both relatively strategic (i.e., available for conscious introspection) and automatic (i.e., outside conscious control) measures of cognitive biases in a sample with either high (n=32) or low (n=31) BDD symptoms. Specifically, we examined the extent that 1) explicit interpretations tied to appearance, as well as 2) automatic associations and 3) strategic evaluations of the importance of attractiveness predict anxiety and avoidance associated with mirror gazing. Results indicated that interpretations tied to appearance uniquely predicted self-reported desire to avoid, while strategic evaluations of appearance uniquely predicted peak anxiety associated with mirror gazing, and automatic appearance associations uniquely predicted behavioral avoidance. These results offer considerable support for cognitive models of BDD, and suggest a dissociation between automatic and strategic measures. PMID:19684496

  11. Automatic Web-Based, Radio-Network System To Monitor And Control Equipment For Investigating Gas Flux At Water - Air Interfaces

    Science.gov (United States)

    Duc, N. T.; Silverstein, S.; Wik, M.; Beckman, P.; Crill, P. M.; Bastviken, D.; Varner, R. K.

    2015-12-01

    Aquatic ecosystems are major sources of greenhouse gases (GHG). Robust measurements of natural GHG emissions are vital for evaluating regional to global carbon budgets and for assessing climate feedbacks on natural emissions to improve climate models. Diffusive and ebullitive (bubble) transport are two major pathways of gas release from surface waters. To capture the high temporal variability of these fluxes in a well-defined footprint, we designed and built an inexpensive automatic device that includes an easily mobile diffusive flux chamber and a bubble counter, all in one. Besides a function of automatically collecting gas samples for subsequent various analyses in the laboratory, this device utilizes low cost CO2 sensor (SenseAir, Sweden) and CH4 sensor (Figaro, Japan) to measure GHG fluxes. To measure the spatial variability of emissions, each of the devices is equipped with an XBee module to enable a local radio communication DigiMesh network for time synchronization and data readout at a server-controller station on the lakeshore. Software of this server-controller is operated on a low cost Raspberry Pi computer which has a 3G connection for remote monitoring - controlling functions from anywhere in the world. From field studies in Abisko, Sweden in summer 2014 and 2015, the system has resulted in measurements of GHG fluxes comparable to manual methods. In addition, the deployments have shown the advantage of a low cost automatic network system to study GHG fluxes on lakes in remote locations.

  12. A device for measuring electron beam characteristics

    Directory of Open Access Journals (Sweden)

    M. Andreev

    2017-01-01

    Full Text Available This paper presents a device intended for diagnostics of electron beams and the results obtained with this device. The device comprises a rotating double probe operating in conjunction with an automated probe signal collection and processing system. This provides for measuring and estimating the electron beam characteristics such as radius, current density, power density, convergence angle, and brightness.

  13. Design and construction of automatic operating system of double chamber plasma nitriding device PLC based

    International Nuclear Information System (INIS)

    Saminto; Slamet Santosa; Eko Priyono

    2012-01-01

    The automatic operating system of double chamber plasma nitriding device has been done. The system is used for operating double chamber plasma nitriding automatically as according to the standard operating procedure by pressing push button on the human machine interface (HMI). The system consists of hardware and software. The hardware was constructed using main components T100MD1616+ PLC module and supported by temperature signal conditioner module, Wheatstone bridge module, isolated amplifier module and EMS 30A H Bridge motor driver module. A software program that is planted on T100MD1616+ PLC using ladder diagrams and Tbasic program. Test system functions performed by inserting a set values of temperature and pressure by pressing the button on the human machine interface (HMI). The test results show that the temperature control with a set of values 100 °C obtained stable coverage of 98 °C to 102 °C, (Δ ± 2 °C) with a 2% tolerance and the output voltage of the DAC is 2.436 volts to 2.913 volts. The pressure control with a set of values 2.169 x 10 -1 mbar obtained stable coverage of 1.995 x 10 -1 mbar to 2.205 x 10 -1 mbar, (Δ ± 0.105 x 10 -1 mbar) with a 5% tol. (author)

  14. Automatic registration method for multisensor datasets adopted for dimensional measurements on cutting tools

    International Nuclear Information System (INIS)

    Shaw, L; Mehari, F; Weckenmann, A; Ettl, S; Häusler, G

    2013-01-01

    Multisensor systems with optical 3D sensors are frequently employed to capture complete surface information by measuring workpieces from different views. During coarse and fine registration the resulting datasets are afterward transformed into one common coordinate system. Automatic fine registration methods are well established in dimensional metrology, whereas there is a deficit in automatic coarse registration methods. The advantage of a fully automatic registration procedure is twofold: it enables a fast and contact-free alignment and further a flexible application to datasets of any kind of optical 3D sensor. In this paper, an algorithm adapted for a robust automatic coarse registration is presented. The method was originally developed for the field of object reconstruction or localization. It is based on a segmentation of planes in the datasets to calculate the transformation parameters. The rotation is defined by the normals of three corresponding segmented planes of two overlapping datasets, while the translation is calculated via the intersection point of the segmented planes. First results have shown that the translation is strongly shape dependent: 3D data of objects with non-orthogonal planar flanks cannot be registered with the current method. In the novel supplement for the algorithm, the translation is additionally calculated via the distance between centroids of corresponding segmented planes, which results in more than one option for the transformation. A newly introduced measure considering the distance between the datasets after coarse registration evaluates the best possible transformation. Results of the robust automatic registration method are presented on the example of datasets taken from a cutting tool with a fringe-projection system and a focus-variation system. The successful application in dimensional metrology is proven with evaluations of shape parameters based on the registered datasets of a calibrated workpiece. (paper)

  15. Device-Independent Certification of a Nonprojective Qubit Measurement

    Science.gov (United States)

    Gómez, Esteban S.; Gómez, Santiago; González, Pablo; Cañas, Gustavo; Barra, Johanna F.; Delgado, Aldo; Xavier, Guilherme B.; Cabello, Adán; Kleinmann, Matthias; Vértesi, Tamás; Lima, Gustavo

    2016-12-01

    Quantum measurements on a two-level system can have more than two independent outcomes, and in this case, the measurement cannot be projective. Measurements of this general type are essential to an operational approach to quantum theory, but so far, the nonprojective character of a measurement can only be verified experimentally by already assuming a specific quantum model of parts of the experimental setup. Here, we overcome this restriction by using a device-independent approach. In an experiment on pairs of polarization-entangled photonic qubits we violate by more than 8 standard deviations a Bell-like correlation inequality that is valid for all sets of two-outcome measurements in any dimension. We combine this with a device-independent verification that the system is best described by two qubits, which therefore constitutes the first device-independent certification of a nonprojective quantum measurement.

  16. Fully automatic measurements of axial vertebral rotation for assessment of spinal deformity in idiopathic scoliosis

    International Nuclear Information System (INIS)

    Forsberg, Daniel; Andersson, Mats; Knutsson, Hans; Lundström, Claes; Vavruch, Ludvig; Tropp, Hans

    2013-01-01

    Reliable measurements of spinal deformities in idiopathic scoliosis are vital, since they are used for assessing the degree of scoliosis, deciding upon treatment and monitoring the progression of the disease. However, commonly used two dimensional methods (e.g. the Cobb angle) do not fully capture the three dimensional deformity at hand in scoliosis, of which axial vertebral rotation (AVR) is considered to be of great importance. There are manual methods for measuring the AVR, but they are often time-consuming and related with a high intra- and inter-observer variability. In this paper, we present a fully automatic method for estimating the AVR in images from computed tomography. The proposed method is evaluated on four scoliotic patients with 17 vertebrae each and compared with manual measurements performed by three observers using the standard method by Aaro–Dahlborn. The comparison shows that the difference in measured AVR between automatic and manual measurements are on the same level as the inter-observer difference. This is further supported by a high intraclass correlation coefficient (0.971–0.979), obtained when comparing the automatic measurements with the manual measurements of each observer. Hence, the provided results and the computational performance, only requiring approximately 10 to 15 s for processing an entire volume, demonstrate the potential clinical value of the proposed method. (paper)

  17. Accuracy of portable devices in measuring peak cough flow

    International Nuclear Information System (INIS)

    Kulnik, Stefan Tino; Kalra, Lalit; MacBean, Victoria; Birring, Surinder Singh; Moxham, John; Rafferty, Gerrard Francis

    2015-01-01

    Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini–Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min −1 when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min −1 . The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable. (paper)

  18. Water quality improving device of nuclear power plant

    International Nuclear Information System (INIS)

    Mori, Tsuguo.

    1994-01-01

    In the device of the present invention, the amount of an oxygen injected to an inlet of a recombiner is automatically controlled by detecting an oxygen concentration at the exit of the recombiner. Accordingly, the range for the concentration of dissolved oxygen at the exit of the recombiner is appropriately maintained. That is, the device of the present invention comprises a hydrogen injection means, hydrogen concentration measuring means, oxygen injection means, oxygen concentration measuring means and control means. If a hydrogen gas is injected to condensates which are to be coolants of the reactor, it is combined with the dissolved oxygen in the coolants. Excessive hydrogen in this case is measured by an off-gas system, and oxygen of an amount corresponding to the amount for combining the excessive hydrogen is injected to the inlet of the recombiner. The oxygen concentration at the exit of the recombiner is measured. If the result of the measurement is out of a predetermined range, the injection amount of oxygen is increased or decreased to conduct automatic control so that oxygen is within a predetermined range. As a result, the improvement for the water quality of the reactor coolants and processing of the excessive hydrogen gas can be conducted smoothly, stably and safely. (I.S.)

  19. Device independent quantum key distribution secure against coherent attacks with memoryless measurement devices

    International Nuclear Information System (INIS)

    McKague, Matthew

    2009-01-01

    Device independent quantum key distribution (QKD) aims to provide a higher degree of security than traditional QKD schemes by reducing the number of assumptions that need to be made about the physical devices used. The previous proof of security by Pironio et al (2009 New J. Phys. 11 045021) applies only to collective attacks where the state is identical and independent and the measurement devices operate identically for each trial in the protocol. We extend this result to a more general class of attacks where the state is arbitrary and the measurement devices have no memory. We accomplish this by a reduction of arbitrary adversary strategies to qubit strategies and a proof of security for qubit strategies based on the previous proof by Pironio et al and techniques adapted from Renner.

  20. Measurement-Device Independency Analysis of Continuous-Variable Quantum Digital Signature

    Directory of Open Access Journals (Sweden)

    Tao Shang

    2018-04-01

    Full Text Available With the practical implementation of continuous-variable quantum cryptographic protocols, security problems resulting from measurement-device loopholes are being given increasing attention. At present, research on measurement-device independency analysis is limited in quantum key distribution protocols, while there exist different security problems for different protocols. Considering the importance of quantum digital signature in quantum cryptography, in this paper, we attempt to analyze the measurement-device independency of continuous-variable quantum digital signature, especially continuous-variable quantum homomorphic signature. Firstly, we calculate the upper bound of the error rate of a protocol. If it is negligible on condition that all measurement devices are untrusted, the protocol is deemed to be measurement-device-independent. Then, we simplify the calculation by using the characteristics of continuous variables and prove the measurement-device independency of the protocol according to the calculation result. In addition, the proposed analysis method can be extended to other quantum cryptographic protocols besides continuous-variable quantum homomorphic signature.

  1. Temperature measurement device

    International Nuclear Information System (INIS)

    Fournier, Christian; Lions, Noel.

    1975-01-01

    The present invention relates to a temperature measuring system that can be applied in particular to monitoring the temperature of the cooling liquid metal of the outlet of the core assemblies of a fast reactor. Said device combines a long hollow metallic pole, at least partially dipped into the liquid metal and constituting a first thermocouple junction between said pole, and two metallic conductors of different nature, joined at one of their ends to constitute the second thermocouple junction. Said conductors suitably insulated are arranged inside a sheath. Said sheath made of the same metals as the pole extends inside the latter and is connected with the pole through a soldered joint. Said reliable system permits an instantaneous measurement of a quantity representing the variations in the recorded temperature and a measurement of the mean surrounding temperature that can be direcly used as a reference for calibrating the first one [fr

  2. Forensic Automatic Speaker Recognition Based on Likelihood Ratio Using Acoustic-phonetic Features Measured Automatically

    Directory of Open Access Journals (Sweden)

    Huapeng Wang

    2015-01-01

    Full Text Available Forensic speaker recognition is experiencing a remarkable paradigm shift in terms of the evaluation framework and presentation of voice evidence. This paper proposes a new method of forensic automatic speaker recognition using the likelihood ratio framework to quantify the strength of voice evidence. The proposed method uses a reference database to calculate the within- and between-speaker variability. Some acoustic-phonetic features are extracted automatically using the software VoiceSauce. The effectiveness of the approach was tested using two Mandarin databases: A mobile telephone database and a landline database. The experiment's results indicate that these acoustic-phonetic features do have some discriminating potential and are worth trying in discrimination. The automatic acoustic-phonetic features have acceptable discriminative performance and can provide more reliable results in evidence analysis when fused with other kind of voice features.

  3. Radon Measurement Proficiency (RMP) Program methods and devices

    International Nuclear Information System (INIS)

    Harrison, J.; Hoornbeek, J.; Jalbert, P.; Sensintaffar, E.; Hopper, R.

    1991-01-01

    The US EPA developed the voluntary Radon Measurement Proficiency Program in 1986 in response to a Federal and State need for measurement services firms to demonstrate their proficiency with radon measurement methods and devices. Since that time, the program has set basic standards for the radon measurement industry. The program has grown dramatically since its inception. In 1986, fewer than 50 companies participated in the program. By 1989, more than 5,000 companies were participating. Participants represent firms with an analytical capability as well as firms that rely upon another firm for analysis service. Since the beginning of the RMP Program, the Agency has learned a great deal about radon measurement methods and devices. This paper reviews the measurement devices used in the program and what the EPA has learned about them since the program's inception. Performance data from the RMP Program are used to highlight relevant findings

  4. Device for the alternative option of temperature measurement

    Science.gov (United States)

    Jargus, Jan; Nedoma, Jan; Fajkus, Marcel; Novak, Martin; Cubik, Jakub; Cvejn, Daniel; Vasinek, Vladimir

    2017-10-01

    Polydimethylsiloxane (PDMS) has good optical properties, and its composition offers the possibility of use in many applications (industry, security device, medicine applications and etc.). We focused on the alternative option of temperature measurement in this article. Our approach is based on measuring changes of chromaticity correlated temperature corresponding to changes in temperature. Described device uses an optical fiber with a defined layer of PDMS and luminophore and we assume that it can find use also in the field of security. The article describes the process of making the prototype of the device and its verification based on laboratory results. The measured temperature depends mainly on the type of optical fiber and the measured temperature range is determined by the thermal resistance of used optical fiber. Using a calibration measurement can determine the value of temperature with an accuracy of +/- 2,5 %.

  5. Automatic Detection of Childhood Absence Epilepsy Seizures: Toward a Monitoring Device

    DEFF Research Database (Denmark)

    Duun-Henriksen, Jonas; Madsen, Rasmus E.; Remvig, Line S.

    2012-01-01

    Automatic detections of paroxysms in patients with childhood absence epilepsy have been neglected for several years. We acquire reliable detections using only a single-channel brainwave monitor, allowing for unobtrusive monitoring of antiepileptic drug effects. Ultimately we seek to obtain optimal...... long-term prognoses, balancing antiepileptic effects and side effects. The electroencephalographic appearance of paroxysms in childhood absence epilepsy is fairly homogeneous, making it feasible to develop patient-independent automatic detection. We implemented a state-of-the-art algorithm...

  6. Automaticity and primacy of auditory streaming: Concurrent subjective and objective measures.

    Science.gov (United States)

    Billig, Alexander J; Carlyon, Robert P

    2016-03-01

    Two experiments used subjective and objective measures to study the automaticity and primacy of auditory streaming. Listeners heard sequences of "ABA-" triplets, where "A" and "B" were tones of different frequencies and "-" was a silent gap. Segregation was more frequently reported, and rhythmically deviant triplets less well detected, for a greater between-tone frequency separation and later in the sequence. In Experiment 1, performing a competing auditory task for the first part of the sequence led to a reduction in subsequent streaming compared to when the tones were attended throughout. This is consistent with focused attention promoting streaming, and/or with attention switches resetting it. However, the proportion of segregated reports increased more rapidly following a switch than at the start of a sequence, indicating that some streaming occurred automatically. Modeling ruled out a simple "covert attention" account of this finding. Experiment 2 required listeners to perform subjective and objective tasks concurrently. It revealed superior performance during integrated compared to segregated reports, beyond that explained by the codependence of the two measures on stimulus parameters. We argue that listeners have limited access to low-level stimulus representations once perceptual organization has occurred, and that subjective and objective streaming measures partly index the same processes. (c) 2016 APA, all rights reserved).

  7. Experimental Measurement-Device-Independent Entanglement Detection

    Science.gov (United States)

    Nawareg, Mohamed; Muhammad, Sadiq; Amselem, Elias; Bourennane, Mohamed

    2015-02-01

    Entanglement is one of the most puzzling features of quantum theory and of great importance for the new field of quantum information. The determination whether a given state is entangled or not is one of the most challenging open problems of the field. Here we report on the experimental demonstration of measurement-device-independent (MDI) entanglement detection using witness method for general two qubits photon polarization systems. In the MDI settings, there is no requirement to assume perfect implementations or neither to trust the measurement devices. This experimental demonstration can be generalized for the investigation of properties of quantum systems and for the realization of cryptography and communication protocols.

  8. Radiation flux measuring device

    International Nuclear Information System (INIS)

    Corte, E.; Maitra, P.

    1977-01-01

    A radiation flux measuring device is described which employs a differential pair of transistors, the output of which is maintained constant, connected to a radiation detector. Means connected to the differential pair produce a signal representing the log of the a-c component of the radiation detector, thereby providing a signal representing the true root mean square logarithmic output. 3 claims, 2 figures

  9. A power measuring device

    International Nuclear Information System (INIS)

    As, R. van.

    1985-01-01

    As a part of the klystron test facility of the Dutch NIKHEF-K accelerator, a sensitive power measuring device has been built. The high-frequency power of a klystron is stored in a water-cooled dummy load. Using a microcomputer, the increase of the water temperature and the water flow rate are transformed to a digital indication of the klystron power. (Auth.)

  10. The use of an electronic portal imaging device for exit dosimetry and quality control measurements

    International Nuclear Information System (INIS)

    Kirby, Michael C.; Williams, Peter C.

    1995-01-01

    Purpose: To determine ways in which electronic portal imaging devices (EPIDs) could be used to (a) measure exit doses for external beam radiotherapy and (b) perform quality control checks on linear accelerators. Methods and Materials: When imaging, our fluoroscopic EPID adjusts the gain, offset, and frame acquisition time of the charge coupled device (CCD) camera automatically, to allow for the range of photon transmissions through the patient, and to optimize the signal-to-noise ratio. However, our EPID can be programmed to act as an integrating dosemeter. EPID dosemeter measurements were made for 20 MV photons, for different field sizes and thicknesses of unit density phantom material placed at varying exit surface to detector distances. These were compared with simultaneous Silicon diode exit dose measurements. Our exit dosimetry technique was verified using an anthropomorphic type phantom, and some initial measurements have been made for patients treated with irregularly shaped 20 MV x-ray fields. In this dosimetry mode, our EPID was also used to measure certain quality control parameters, x-ray field flatness, and the verification of segmented intensity modulated field prescriptions. Results: Configured for dosimetry, our EPID exhibited a highly linear response, capable of resolving individual monitor units. Exit doses could be measured to within about 3% of that measured using Silicon diodes. Field flatness was determined to within 1.5% of Farmer dosemeter measurements. Segmented intensity modulated fields can be easily verified. Conclusions: Our EPID has the versatility to assess a range of parameters pertinent to the delivery of high quality, high precision radiotherapy. When configured appropriately, it can measure exit doses in vivo, with reasonable accuracy, perform certain quick quality control checks, and analyze segmented intensity modulated treatment fields

  11. Automatic Measurement in Large-Scale Space with the Laser Theodolite and Vision Guiding Technology

    Directory of Open Access Journals (Sweden)

    Bin Wu

    2013-01-01

    Full Text Available The multitheodolite intersection measurement is a traditional approach to the coordinate measurement in large-scale space. However, the procedure of manual labeling and aiming results in the low automation level and the low measuring efficiency, and the measurement accuracy is affected easily by the manual aiming error. Based on the traditional theodolite measuring methods, this paper introduces the mechanism of vision measurement principle and presents a novel automatic measurement method for large-scale space and large workpieces (equipment combined with the laser theodolite measuring and vision guiding technologies. The measuring mark is established on the surface of the measured workpiece by the collimating laser which is coaxial with the sight-axis of theodolite, so the cooperation targets or manual marks are no longer needed. With the theoretical model data and the multiresolution visual imaging and tracking technology, it can realize the automatic, quick, and accurate measurement of large workpieces in large-scale space. Meanwhile, the impact of artificial error is reduced and the measuring efficiency is improved. Therefore, this method has significant ramification for the measurement of large workpieces, such as the geometry appearance characteristics measuring of ships, large aircraft, and spacecraft, and deformation monitoring for large building, dams.

  12. Automatic Emboli Detection System for the Artificial Heart

    Science.gov (United States)

    Steifer, T.; Lewandowski, M.; Karwat, P.; Gawlikowski, M.

    In spite of the progress in material engineering and ventricular assist devices construction, thromboembolism remains the most crucial problem in mechanical heart supporting systems. Therefore, the ability to monitor the patient's blood for clot formation should be considered an important factor in development of heart supporting systems. The well-known methods for automatic embolus detection are based on the monitoring of the ultrasound Doppler signal. A working system utilizing ultrasound Doppler is being developed for the purpose of flow estimation and emboli detection in the clinical artificial heart ReligaHeart EXT. Thesystem will be based on the existing dual channel multi-gate Doppler device with RF digital processing. A specially developed clamp-on cannula probe, equipped with 2 - 4 MHz piezoceramic transducers, enables easy system setup. We present the issuesrelated to the development of automatic emboli detection via Doppler measurements. We consider several algorithms for the flow estimation and emboli detection. We discuss their efficiency and confront them with the requirements of our experimental setup. Theoretical considerations are then met with preliminary experimental findings from a) flow studies with blood mimicking fluid and b) in-vitro flow studies with animal blood. Finally, we discuss some more methodological issues - we consider several possible approaches to the problem of verification of the accuracy of the detection system.

  13. Automatic Blood Pressure Measurements During Exercise

    Science.gov (United States)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  14. Reactor core control device

    International Nuclear Information System (INIS)

    Sano, Hiroki

    1998-01-01

    The present invention provides a reactor core control device, in which switching from a manual operation to an automatic operation, and the control for the parameter of an automatic operation device are facilitated. Namely, the hysteresis of the control for the operation parameter by an manual operation input means is stored. The hysteresis of the control for the operation parameter is collected. The state of the reactor core simulated by an operation control to which the collected operation parameters are manually inputted is determined as an input of the reactor core state to the automatic input means. The record of operation upon manual operation is stored as a hysteresis of control for the operation parameter, but the hysteresis information is not only the result of manual operation of the operation parameter. This is results of operation conducted by a skilled operator who judge the state of the reactor core to be optimum. Accordingly, it involves information relevant to the reactor core state. Then, it is considered that the optimum automatic operation is not deviated greatly from the manual operation. (I.S.)

  15. Automatic size analysis of coated fuel particles

    International Nuclear Information System (INIS)

    Wallisch, K.; Koss, P.

    1977-01-01

    The determination of the diameter, coating thickness, and sphericity of coated fuel particles by conventional methods is very time consuming. Therefore, statistical data can only be obtained with limited accuracy. An alternative method is described that avoids these disadvantages by utilizing a fast optical data-collecting system of high accuracy. This system allows the determination of the diameter of particles in the range between 100 and 1500 μm, with an accuracy of better than +-2 μm and with a rate of 100 particles per second. The density and thickness of coating layers can be determined by comparing the data obtained before and after coating, taking into account the relative increase of weight. A special device allows the automatic determination of the sphericity of single particles as well as the distribution in a batch. This device measures 50 to 100 different diameters of each particle per second. An on-line computer stores the measured data and calculates all parameters required, e.g., number of particles measured, particle diameter, standard deviation, diameter limiting values, average particle volume, average particle surface area, and the distribution of sphericity in absolute and percent form

  16. A Practical Device for Measuring the Luminance Distribution

    Directory of Open Access Journals (Sweden)

    Thijs Kruisselbrink

    2017-06-01

    Full Text Available Various applications in building lighting such as automated daylight systems, dynamic lighting control systems, lighting simulations, and glare analyzes can be optimized using information on the actual luminance distributions of the surroundings. Currently, commercially available luminance distribution measurement devices are often not suitable for these kind of applications or simply too expensive for broad application. This paper describes the development of a practical and autonomous luminance distribution measurement device based on a credit card-sized single-board computer and a camera system. The luminance distribution was determined by capturing High Dynamic Range images and translating the RGB information to the CIE XYZ color space. The High Dynamic Range technology was essential to accurately capture the data needed to calculate the luminance distribution because it allows to capture luminance ranges occurring in real scenarios. The measurement results were represented in accordance with established methods in the field of daylighting. Measurements showed that the accuracy of the luminance distribution measurement device ranged from 5% to 20% (worst case which was deemed acceptable for practical measurements and broad applications in the building realm.

  17. Connection of control circuits of machine for automatic measurement of radioactive samples

    International Nuclear Information System (INIS)

    Vorlicek, J.

    1984-01-01

    A windowless through-flow gas detector is used for measurement. The automatic machine is controlled by four flip-flops defining the following states: the dish replacement in the measuring space, washing, measurement, measured value print-out, and resetting. The first and second outputs of the first, second and third flip-flops are connected to six inputs of a block whose four outputs provide counter reset and stop-watch reset, washing, measurement, and print-out. Such machine control eliminates measurement errors by disabling sample measurement until air is removed from the measurement space, introduced on an unwashed dish or on several dishes passed under the detector. The elimination of this error is also guaranteed in manual operation. (M.D.)

  18. Measuring ionizing radiation with a mobile device

    Science.gov (United States)

    Michelsburg, Matthias; Fehrenbach, Thomas; Puente León, Fernando

    2012-02-01

    In cases of nuclear disasters it is desirable to know one's personal exposure to radioactivity and the related health risk. Usually, Geiger-Mueller tubes are used to assess the situation. Equipping everyone with such a device in a short period of time is very expensive. We propose a method to detect ionizing radiation using the integrated camera of a mobile consumer device, e.g., a cell phone. In emergency cases, millions of existing mobile devices could then be used to monitor the exposure of its owners. In combination with internet access and GPS, measured data can be collected by a central server to get an overview of the situation. During a measurement, the CMOS sensor of a mobile device is shielded from surrounding light by an attachment in front of the lens or an internal shutter. The high-energy radiation produces free electrons on the sensor chip resulting in an image signal. By image analysis by means of the mobile device, signal components due to incident ionizing radiation are separated from the sensor noise. With radioactive sources present significant increases in detected pixels can be seen. Furthermore, the cell phone application can make a preliminary estimate on the collected dose of an individual and the associated health risks.

  19. Temperature measurement with industrial color camera devices

    Science.gov (United States)

    Schmidradler, Dieter J.; Berndorfer, Thomas; van Dyck, Walter; Pretschuh, Juergen

    1999-05-01

    This paper discusses color camera based temperature measurement. Usually, visual imaging and infrared image sensing are treated as two separate disciplines. We will show, that a well selected color camera device might be a cheaper, more robust and more sophisticated solution for optical temperature measurement in several cases. Herein, only implementation fragments and important restrictions for the sensing element will be discussed. Our aim is to draw the readers attention to the use of visual image sensors for measuring thermal radiation and temperature and to give reasons for the need of improved technologies for infrared camera devices. With AVL-List, our partner of industry, we successfully used the proposed sensor to perform temperature measurement for flames inside the combustion chamber of diesel engines which finally led to the presented insights.

  20. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  1. A test chip for automatic reliability measurements of interconnect vias

    NARCIS (Netherlands)

    Lippe, K.; Hasper, A.; Elfrink, G.W.; Niehof, J.; Kerkhoff, Hans G.

    1992-01-01

    A test circuit for electromigration reliability measurements was designed and tested. The device under test (DUT) is a via-hole chain. The test circuit permits simultaneous measurements of a number of DUTs, and a fatal error of one DUT does not influence the measurement results of the other DUTs.

  2. Using Teacher-Made Measurement Devices.

    Science.gov (United States)

    Mehrens, William A.; Lehmann, Irvin J.

    1987-01-01

    Classroom measurement devices, when tailored to fit a teacher's particular instructional objectives, are essential for optimal teaching and learning. Teachers use test data to assess students' progress but often fail to analyze tests for validity. This article shows how locally and correctly developed assessment tools may serve a variety of…

  3. Dynamic Analysis of a Pendulum Dynamic Automatic Balancer

    Directory of Open Access Journals (Sweden)

    Jin-Seung Sohn

    2007-01-01

    Full Text Available The automatic dynamic balancer is a device to reduce the vibration from unbalanced mass of rotors. Instead of considering prevailing ball automatic dynamic balancer, pendulum automatic dynamic balancer is analyzed. For the analysis of dynamic stability and behavior, the nonlinear equations of motion for a system are derived with respect to polar coordinates by the Lagrange's equations. The perturbation method is applied to investigate the dynamic behavior of the system around the equilibrium position. Based on the linearized equations, the dynamic stability of the system around the equilibrium positions is investigated by the eigenvalue analysis.

  4. Spill-Detector-and-Shutoff Device

    Science.gov (United States)

    Jarvis, M. R.; Fulton, D. S.

    1985-01-01

    Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.

  5. Scattering measurements in Tokamak type devices

    International Nuclear Information System (INIS)

    Matoba, Tohru

    1975-03-01

    Theories, experiments and proposals for light scattering in Tokamak type devices are reviewed. Thomson scattering, measuring method of the current density distribution by scattering and resonance fluorescence are summarily described. These methods may be useful for diagnosis of the fusion plasmas. The report may help planning of the measuring apparatus for the fusion plasmas in future. (auth.)

  6. Measurement Devices and the Psychophysiology of Consumer Behaviour

    DEFF Research Database (Denmark)

    Schwarzkopf, Stefan

    2015-01-01

    of the type of subjectivity that underlies consumer behaviour. I argue instead that a posthuman view of the relationship between brain, mind and behaviour underpinned neurophysiological research into consumers from its very beginning in the late nineteenth century. By tracing the biopolitical potentialities...... of neuromarketing back to the Fin-de-Siècle neurophysiological laboratory, I show that consumers' bodies and later on their brains became reconfigured as part of a dispositif made up of laboratory-based artefacts (measurement devices) and new ways of seeing the human brain and human behaviour. This dispositif......From the 1890s, psychophysiological measurement devices have played an important, but as yet under-theorized role in marketing and consumer research. Because of the recent advances made in neuromarketing, it is often assumed that these measurement devices ushered in a radically new understanding...

  7. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  8. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  9. Device for the analysis of feedwater and condensation samples from power plants

    International Nuclear Information System (INIS)

    Mostofin, A.A.; Sorokina, N.S.

    1978-01-01

    An improved version of a device for automatic measurement of the salt and NH 3 contents of feedwater and condensate samples from nuclear power plants is described. Only one sample is required for determining both values. The invention proposes on the one hand to change the dimensions of a throttle opening and on the other to install a second measuring instrument (conductivity measuring instrument). (UWI) [de

  10. Automatic content linking: Speech-based just-in-time retrieval for multimedia archives

    NARCIS (Netherlands)

    Popescu-Belis, A.; Kilgour, J.; Poller, P.; Nanchen, A.; Boertjes, E.; Wit, J. de

    2010-01-01

    The Automatic Content Linking Device monitors a conversation and uses automatically recognized words to retrieve documents that are of potential use to the participants. The document set includes project related reports or emails, transcribed snippets of past meetings, and websites. Retrieval

  11. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  12. The Siegen automatic measuring system for nuclear track detectors: new developments

    International Nuclear Information System (INIS)

    Noll, A.; Rusch, G.; Roecher, H.; Dreute, J.; Heinrich, W.

    1988-01-01

    Starting ten years ago we developed completely automatic scanning and measuring systems for nuclear track detectors. In this paper we describe some new developments. Our autofocus systems based on the contrast of the video picture and on a laser autofocus have been improved in speed and in reliability. Based on new algorithms, faster programs have been developed to scan for nuclear tracks in plastic detectors. Methods for separation of overlapping tracks have been improved. Interactive programs for track measurements have been developed which are very helpful for space bio-physics experiments. Finally new methods for track measurements in nuclear emulsions irradiated with a beam perpendicular to the detector surface are described in this paper. (author)

  13. Ratbot automatic navigation by electrical reward stimulation based on distance measurement in unknown environments.

    Science.gov (United States)

    Gao, Liqiang; Sun, Chao; Zhang, Chen; Zheng, Nenggan; Chen, Weidong; Zheng, Xiaoxiang

    2013-01-01

    Traditional automatic navigation methods for bio-robots are constrained to configured environments and thus can't be applied to tasks in unknown environments. With no consideration of bio-robot's own innate living ability and treating bio-robots in the same way as mechanical robots, those methods neglect the intelligence behavior of animals. This paper proposes a novel ratbot automatic navigation method in unknown environments using only reward stimulation and distance measurement. By utilizing rat's habit of thigmotaxis and its reward-seeking behavior, this method is able to incorporate rat's intrinsic intelligence of obstacle avoidance and path searching into navigation. Experiment results show that this method works robustly and can successfully navigate the ratbot to a target in the unknown environment. This work might put a solid base for application of ratbots and also has significant implication of automatic navigation for other bio-robots as well.

  14. Classification of methods for measuring current-voltage characteristics of semiconductor devices

    Directory of Open Access Journals (Sweden)

    Iermolenko Ia. O.

    2014-06-01

    Full Text Available It is shown that computer systems for measuring current-voltage characteristics are very important for semiconductor devices production. The main criteria of efficiency of such systems are defined. It is shown that efficiency of such systems significantly depends on the methods for measuring current-voltage characteristics of semiconductor devices. The aim of this work is to analyze existing methods for measuring current-voltage characteristics of semiconductor devices and to create the classification of these methods in order to specify the most effective solutions in terms of defined criteria. To achieve this aim, the most common classifications of methods for measuring current-voltage characteristics of semiconductor devices and their main disadvantages are considered. Automated and manual, continuous, pulse, mixed, isothermal and isodynamic methods for measuring current-voltage characteristics are analyzed. As a result of the analysis and generalization of existing methods the next classification criteria are defined: the level of automation, the form of measurement signals, the condition of semiconductor device during the measurements, and the use of mathematical processing of the measurement results. With the use of these criteria the classification scheme of methods for measuring current-voltage characteristics of semiconductor devices is composed and the most effective methods are specified.

  15. Automatic device for measuring {beta}-emitting sources: P.A.P.A. {beta}-meters; Dispositif automatique pour la mesure de sources emettrices de rayonnement {beta}: P.A.P.A. {beta} metres

    Energy Technology Data Exchange (ETDEWEB)

    Colomer, J; Valentin, M [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    The apparatus described is designed for measuring {beta}-emitting elements by the absorption method; it is suitable for carrying out a large number of routine analyses. A mechanical device pushes an aluminium absorption set automatically between the source and the detector; the movement is programmed for cutting on and off by a transistorized electronic unit, with printing out and punching of the results on tape; then this can be mathematically processed by a computer (tracing of absorption spectra, extrapolation and calculation of the activity). The detector is either a {beta}-probe or a proportional counter with a specially designed loop. For routine measurements, the accuracy obtained, with all corrections made, is from 5 to 8 per cent; the reproducibility is about 2 per cent. (authors) [French] L'appareillage decrit est destine aux mesures des elements emetteurs {beta} par la methode d'absorption et il permet d'effectuer, en routine, un nombre important de mesures. Un ensemble mecanique effectue le passage automatique, sous vide primaire, d'un jeu d'absorption en aluminium entre la source et le detecteur, ce passage est programme en pre-temps ou pre-coup par un ensemble electronique a transistors, avec impression et perforation sur bandes des resultats des mesures pour traitement mathematique par un ordinateur (trace du spectre d'absorption, extrapolation et calcul d'activite). Le detecteur est soit une sonde {beta}, soit un compteur proportionnel a boucle specialement realise. Sur des mesures de routine, la precision obtenue, toutes corrections effectuees, est de 5 a 8 pour cent et la reproductibilite de l'ordre de 2 pour cent. (auteur)

  16. A method for the automatic separation of the images of galaxies and stars from measurements made with the COSMOS machine

    International Nuclear Information System (INIS)

    MacGillivray, H.T.; Martin, R.; Pratt, N.M.; Reddish, V.C.; Seddon, H.; Alexander, L.W.G.; Walker, G.S.; Williams, P.R.

    1976-01-01

    A method has been developed which allows the computer to distinguish automatically between the images of galaxies and those of stars from measurements made with the COSMOS automatic plate-measuring machine at the Royal Observatory, Edinburgh. Results have indicated that a 90 to 95 per cent separation between galaxies and stars is possible. (author)

  17. Data-acquisition system of the reversed field pinch device REPUTE-1

    International Nuclear Information System (INIS)

    Tsuzuki, N.; Aoki, H.; Shinohara, H.; Toyama, H.; Morikawa, J.

    1988-01-01

    The new, compact data-acquisition system of the reversed field pinch device, REPUTE-1, is reported. Its distinctive feature is high flexibility and easy handling. The interface between the computer and measurement devices is CAMAC. The computer and the CAMAC devices are connected to a CAMAC byte serial highway that transmits setup parameters and acquisition data. The computer carries out setup of CAMAC devices and data acquisition automatically by use of CAMAC parameters and the acquisition data base. The maintenance tools for the data base are also provided. The computer system, which consists of a ''TOSBAC DS-600,'' has been in operation for REPUTE-1 since 1985

  18. Development of failure-detecting device for γ radioimmunoassay counter

    International Nuclear Information System (INIS)

    Shao Xianzhi; Zhang Bingfeng

    1997-01-01

    A failures-detecting device based on single chip microcomputer technique for detecting of failures of γ radioimmunoassay counter is developed. The device can output signals of variable amplitude and frequency similar to the pulse of γ particle for shooting problem parts of γ counter's detecting system. By automatically comparing the shapes and amplitudes of the two signals to and from an amplifier unit, the device can distinguish if the amplifier unit works normally. The differential-input amplifier circuit gives 0.1% accuracy for the measurement of the stability of high voltage. The pulse widen circuit of this device allows for middle speed A/D detecting of periodical low-frequency pulse waves of micro-second width. This device is used specifically for the maintaining and failure-detecting of γ radioimmunoassay counter

  19. Pressure and Relative Humidity Measurement Devices for Mars 2020 Rover

    Science.gov (United States)

    Hieta, M.; Genzer, M.; Nikkanen, T.; Haukka, H.; Harri, A.-M.; Polkko, J.; Rodriguez-Manfredi, J. A.

    2017-09-01

    One of the scientific payloads onboard the NASA Mars 2020 rover mission is Mars Environmental Dynamic Analyzer (MEDA): a set of environmental sensors for Mars surface weather measurements. Finnish Meteorological Institute (FMI) provides a pressure measurement device (MEDA PS) and a relative humidity measurement device (MEDA HS) for MEDA.

  20. Pressure measurements in magnetic-fusion devices

    International Nuclear Information System (INIS)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration

  1. Pressure measurements in magnetic-fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration.

  2. Control of the technological processes at ''Azovstal'' plant using radioisotope devices

    Energy Technology Data Exchange (ETDEWEB)

    Nosochenko, O V; Overchenko, Z V; Karpov, O I; Deryabina, G N

    1980-05-01

    Considered is the state of radioisotope control of the technological process at 'Azovstal' plant which has permitted to increase the quality of metal and of metal production. With the help of radioisotope densimeter PR-1024 carried out is the control of the density of the lime solution used for hearth spraying at pig iron casting. A system of automatic correction of skip coke supply according to indications of moisture gauges ''Neutron 3-1'' is implemented at blast furnaces. A radioisotope thickness gauge of hot rolling is positioned on the section of finishing stand of thick-sheet plant, its operation is based on the ..gamma.. radiation weakening in dependence on sheet thickness. The introduction of thickness gauges in the automatized system of rolling control is planned. A radioisotope device ''Paza 2'' for measuring of continuous ingot skin thickness is tested successively at the plant. Gamma-relay devices are used to control the level of loose materials in bunkers. Noted is the prospects of using radioisotopic means of control and automatization of technological processes in ferrous matallurgy.

  3. Design scheme of automatic feeding equipment of domestic uranium chemical concentrate

    International Nuclear Information System (INIS)

    Hu Jinming; Wang Chao; Peng Jinhui; Zhang Libo

    2014-01-01

    In order to solve problems by artificial feeding mode with low work efficiency, large intensity manual labor and environmental pollution in domestic uranium concentrate purification process, the design scheme of automatic feeding device was set up, including work flow sheet, composition of automatic equipment and operation. By application of automatic feeding equipment, the feeding speed can be greatly increased, labor force can be reduced, and harm to workman health can be decreased. (authors)

  4. 32P-postlabeling assay for carcinogen-DNA adducts: description of beta shielding apparatus and semi-automatic spotting and washing devices that facilitate the handling of multiple samples

    International Nuclear Information System (INIS)

    Reddy, M.V.; Blackburn, G.R.

    1990-01-01

    The utilization of the 32 P-postlabeling assay in combination with TLC for the sensitive detection and estimation of aromatic DNA adducts has been increasing. The procedure consists of 32 P-labeling of carcinogen-adducted 3'-nucleotides in the DNA digests using γ- 32 P ATP and polynucleotide kinase, separation of 32 P-labeled adducts by TLC, and their detection by autoradiography. During both 32 P-labeling and initial phases of TLC, a relatively high amount of γ- 32 P ATP is handled when 30 samples are processed simultaneously. We describe the design of acrylic shielding apparatus, semi-automatic TLC spotting devices, and devices for development and washing of multiple TLC plates, which not only provide substantial protection from exposure to 32 P beta radiation, but also allow quick and easy handling of a large number of samples. Specifically, the equipment includes: (i) a multi-tube carousel rack having 15 wells to hold capless Eppendorf tubes and a rotatable lid with an aperture to access individual tubes; (ii) a pipette shielder; (iii) two semi-automatic spotting devices to apply radioactive solutions to TLC plates; (iv) a multi-plate holder for TLC plates; and (v) a mechanical device for washing multiple TLC plates. Item (i) is small enough to be held in one-hand, vortexed, and centrifuged to mix the solutions in each tube while beta radiation is shielded. Items (iii) to (iv) aid in the automation of the assay. (author)

  5. INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS

    Directory of Open Access Journals (Sweden)

    G. T. Kulakov

    2015-01-01

    Full Text Available The usage of digital micro-processing automatic means allow to use design methods (technique of automatic control systems  more wider, and also to apply optimal ways of control, for example, it is possible to combine the Method of structural-parameter optimization and invariance theory. This method allow to increase essential system speed in processing of task jump and to reduce operation time of outside external disturbance up to two  values of regulated influence, and the usage of invariance principle is based on an additional measuring of the most dangerous perturbation influence and in connection with it the improvement of regulation quality is achieved.In this article the principle of invariance is applied in order to improve greatly external disturbance attack by consumption of over-heated steam. Compensation of disturbance influence on regulated value is achieving by introduction of additional signal on input of correction regulator from output of compensation device, measuring the external disturbance by consumption of over-heated steam.Modeling results of transient processes of cascade system of automatic control (CSAC, on the base of which were realized the unity of these methods, demonstrated the fact that, in processing of external disturbance by consumption of steam, the reduction of maximal dynamic regulation error is six times and cutting of regulation time by 30 % in comparison with CSAC without compensation device of external disturbance. And that is why it leads to the further reduction of maximal dynamic regulation error in processing of external disturbance by consumption of steam, and this allows to improve the quality of control.

  6. Automatic calibration system of the temperature instrument display based on computer vision measuring

    Science.gov (United States)

    Li, Zhihong; Li, Jinze; Bao, Changchun; Hou, Guifeng; Liu, Chunxia; Cheng, Fang; Xiao, Nianxin

    2010-07-01

    With the development of computers and the techniques of dealing with pictures and computer optical measurement, various measuring techniques are maturing gradually on the basis of optical picture processing technique and using in practice. On the bases, we make use of the many years' experience and social needs in temperature measurement and computer vision measurement to come up with the completely automatic way of the temperature measurement meter with integration of the computer vision measuring technique. It realizes synchronization collection with theory temperature value, improves calibration efficiency. based on least square fitting principle, integrate data procession and the best optimize theory, rapidly and accurately realizes automation acquisition and calibration of temperature.

  7. Device for measuring fission product density

    International Nuclear Information System (INIS)

    Kaneda, Mitsunori.

    1980-01-01

    Purpose: To determine the fission product density of xenon or the like and enable measurement of real time of fission product density in a reactor by calculating the disintegration and annihilation of the fission product on the basis of neutron detected output. Constitution: The neutron flux in a reactor is detected by a detector, and applied to first and second density calculators. Second fission product density signal of xenon or the like outputted from first device is again inputted to the device to form an annihilation signal due to disintegration to determine the present density of the second fission product of xenon or the like corresponding to the decrease of the neutron due to the poison of xeron or the like. Similarly, second device determines the first fission product density of iodine or the like. (Sekiya, K.)

  8. Automatic computation of 2D cardiac measurements from B-mode echocardiography

    Science.gov (United States)

    Park, JinHyeong; Feng, Shaolei; Zhou, S. Kevin

    2012-03-01

    We propose a robust and fully automatic algorithm which computes the 2D echocardiography measurements recommended by America Society of Echocardiography. The algorithm employs knowledge-based imaging technologies which can learn the expert's knowledge from the training images and expert's annotation. Based on the models constructed from the learning stage, the algorithm searches initial location of the landmark points for the measurements by utilizing heart structure of left ventricle including mitral valve aortic valve. It employs the pseudo anatomic M-mode image generated by accumulating the line images in 2D parasternal long axis view along the time to refine the measurement landmark points. The experiment results with large volume of data show that the algorithm runs fast and is robust comparable to expert.

  9. Beam diagnostics using an emittance measurement device

    International Nuclear Information System (INIS)

    Sarstedt, M.; Becker, R.; Klein, H.; Maaser, A.; Mueller, J.; Thomae, R.; Weber, M.

    1995-01-01

    For beam diagnostics aside from Faraday cups for current measurements and analysing magnets for the determination of beam composition and energy the most important tool is an emittance measurement device. With such a system the distribution of the beam particles in phase-space can be determined. This yields information not only on the position of the particles but also on their angle with respect to the beam axis. There are different kinds of emittance measurement devices using either circular holes or slits for separation of part of the beam. The second method (slit-slit measurement), though important for the determination of the rms-emittance, has the disadvantage of integrating over the y- and y'-coordinate (measurement in xx'-plane assumed). This leads to different emittance diagrams than point-point measurements, since in xx'-plane for each two corresponding points of rr'-plane there exists a connecting line. With regard to beam aberrations this makes xx'-emittances harder to interpret. In this paper the two kinds of emittance diagrams are discussed. Additionally the influence of the slit height on the xx'-emittance is considered. The analytical results are compared to experimental measurements in rr'-, rx'- and xx'-phase-space. (orig.)

  10. A bottom-up approach to automatically configured Tango control systems

    International Nuclear Information System (INIS)

    Rubio-Manrique, S.; Beltran, D.; Costa, I.; Fernandez-Carreiras, D.; Gigante, J.V.; Klora, J.; Matilla, O.; Ranz, R.; Ribas, J.; Sanchez, O.

    2012-01-01

    Alba is the first synchrotron light source built in Spain. Most of Alba control system has been developed on top of Tango control system. An amount of 5531 devices are controlled in Alba accelerators (linac, booster and storage ring) using 150 Linux PCs. Alba maintains a central repository, so called 'Cabling and Controls database' (CCDB), which keeps the inventory of equipment, cables, connections and their configuration and technical specifications. The valuable information kept in this MySQL database enables some tools to automatically create and configure Tango devices and other software components of the control systems of Accelerators, beamlines and laboratories. This paper describes the process involved in this automatic setup

  11. The Reliability of a Novel Mobile 3-dimensional Wound Measurement Device.

    Science.gov (United States)

    Anghel, Ersilia L; Kumar, Anagha; Bigham, Thomas E; Maselli, Kathryn M; Steinberg, John S; Evans, Karen K; Kim, Paul J; Attinger, Christopher E

    2016-11-01

    Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P device yielded correlations of ρ = 0.990, 0.987, 0.996 with P device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.

  12. [Electronic Device for Retinal and Iris Imaging].

    Science.gov (United States)

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  13. Automatic control device for the reduction of reactor power

    International Nuclear Information System (INIS)

    Sumida, Susumu; Mizuno, Hiroshi.

    1982-01-01

    Purpose: To early detect troubles in condensate pipeways and feedwater pipeways of BWR-type reactor. Constitution: Detectors are provided to a condensate pipe, a condensator, a low pressure condensate pump, a condensate desalting device and a high pressure condensate pump for constituting condensate pipeways, as well as to a feedwater heater, a feedwater pipe and a feedwater pump for constituting feedwater pipeways. Each of the detectors is connected by way of a lead wire to an abnormal detection and processing device. The abnormal detection and processing device, which are connected to a recycling control device, monitor the input from the detector and sends a control signal to the recycling control system upon calculation of a trouble signal from the detector. (Sekiya, K.)

  14. A device for electron gun emittance measurement

    International Nuclear Information System (INIS)

    Aune, B.; Corveller, P.; Jablonka, M.; Joly, J.M.

    1985-05-01

    In order to improve the final emittance of the beam delivered by the ALS electron linac a new gun is going to be installed. To measure its emittance and evaluate the contribution of different factors to emittance growth we have developed an emittance measurement device. We describe the experimental and mathematical procedure we have followed, and give some results of measurements

  15. Automatic diagnostic system for measuring ocular refractive errors

    Science.gov (United States)

    Ventura, Liliane; Chiaradia, Caio; de Sousa, Sidney J. F.; de Castro, Jarbas C.

    1996-05-01

    Ocular refractive errors (myopia, hyperopia and astigmatism) are automatic and objectively determined by projecting a light target onto the retina using an infra-red (850 nm) diode laser. The light vergence which emerges from the eye (light scattered from the retina) is evaluated in order to determine the corresponding ametropia. The system basically consists of projecting a target (ring) onto the retina and analyzing the scattered light with a CCD camera. The light scattered by the eye is divided into six portions (3 meridians) by using a mask and a set of six prisms. The distance between the two images provided by each of the meridians, leads to the refractive error of the referred meridian. Hence, it is possible to determine the refractive error at three different meridians, which gives the exact solution for the eye's refractive error (spherical and cylindrical components and the axis of the astigmatism). The computational basis used for the image analysis is a heuristic search, which provides satisfactory calculation times for our purposes. The peculiar shape of the target, a ring, provides a wider range of measurement and also saves parts of the retina from unnecessary laser irradiation. Measurements were done in artificial and in vivo eyes (using cicloplegics) and the results were in good agreement with the retinoscopic measurements.

  16. Automatic QRS complex detection algorithm designed for a novel wearable, wireless electrocardiogram recording device

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Egstrup, Kenneth; Branebjerg, Jens

    2012-01-01

    We have designed and optimized an automatic QRS complex detection algorithm for electrocardiogram (ECG) signals recorded with the DELTA ePatch platform. The algorithm is able to automatically switch between single-channel and multi-channel analysis mode. This preliminary study includes data from ...

  17. Device for measuring well twistings

    Energy Technology Data Exchange (ETDEWEB)

    Kostin, Yu S; Golubin, S V; Keller, V F; Merzheyevskiy, A B; Zdorov, V P

    1982-01-01

    The device for measuring the well twistings with the use of fluids (poured into a vessel and which leave an imprint on the walls), containing a housing and adapter, is distinguished by the fact that in order to improve the accuracy of measurement by obtaining a clear imprint, it is equipped with cylinder that is spring-loaded in relation to the adapter, forming a vessel for fluid with the adapter. The adapter is made of two parts, one of which is made of neutral metal in relation to the fluid, and the other, from active in relation to the same fluid.

  18. The design of an automatically-tuned beamline

    International Nuclear Information System (INIS)

    Ball, M.S.; Ellison, T.J.P.; Hamilton, B.J.; Jones, W.P.

    1994-01-01

    A new 30 m beamline (BL1C) is being assembled to connect the new High Intensity Polarized Ion Source (HIPIOS) to the IUCF cyclotrons. This line is being instrumented for complete automatic optimization of all transverse and longitudinal ion optical elements by providing a unique feedback signal for each controllable device. Transversely, steerers and 4-quadrant electrostatic pickups are located approximately 90 degree apart in betatron phase advance along the beamline. Each pickup is instrumented with a single-board, 4-layer op-amp circuit (BPM system) which measures the beam intensity, horizontal (H) and vertical (V) position, and H and V 10 Hz position modulation. The transverse beam ellipse parameters are first automatically determined at the entrance to the beamline by measuring the beam size using a wire scanner as a function of the strength of a quadrupole. The computer then programs the amplitude and phase of four 10 Hz modulators which vary the current in 4 steerers to move the beam centroid around this (reduced area) ellipse in 4-dimensional phase space. The BPM system then outputs voltages proportional to the beam intensity, centroid location, and envelope. Computer algorithms will then set the steerers and quadrupoles to correct the beam position, dispersion, and envelope. Longitudinally, hardware feedback loops, with a bandwidth adjustable from 10 Hz to 30 kHz, will phase-lock the beam to the two bunching systems; another hardware system will automatically vary the buncher amplitudes to compensate for the significant and varying space charge defocusing as the beam current fluctuates. The bunchers' quiescent phases and amplitudes will be optimized using software ''synchronous detectors.''

  19. Comparison of parallel temperature measurements from conventional and automatic weather stations at Fabra Observatory (Barcelona).

    Science.gov (United States)

    Aguilar, Enric; Gilabert, Alba; Prohom, Marc

    2013-04-01

    Fabra Observatory , located in a promontory at 411 meters above sea level in the outskirts of Barcelona, hosts a continuous climate record since 1913. Additionally, it has been recording since 1996 simultaneous temperature and precipitation data with conventional instruments and automated systems. The automatization of recording sites employed with climatological purposes is happening elsewhere in the country and across the globe. Unfortunately, in most cases long lasting parallel measurements, are not kept. Thereafter, this site offers an excellent opportunity to study the impact of the introduction of Automatic Weather Stations (AWS). The conventional station (CON) equips a liquid in glass thermometer, located inside a standard Stevenson screen. The automatic measurements (AWS) have been taken using MCV-STA sensors sheltered in a MCV small plate-like ventilated screen between 1996 and the end of July 2007. For our analysis, this MCV period is split in two (T1, T2) due to an obvious jump in the differences AWS-CON in October 2002, produced by unknown reasons. From August 2007 to the present (T3), a Vaisala HMP45AL sensor was placed inside a Stevenson Screen and used for automatic measurements. For daily maximum temperatures, the median differences reach 3.2°C in T1, 1.1°C in T2 and merely -0.1°C in T3. In this later period, 94% of the differences are comprised in a ±0.5°C range, compared to 23% in T2 and only 6% in T1. It is interesting to note how the overheating of the MCV screen dominates the difference series, as 85% of the AWS values taken in T1 and T2 are warmer than the conventional measurements, contrasting with only 27% of cases during T3, when the automated measurements were taken inside a Stevenson screen. These differences are highly temperature dependent: low (high) AWS temperatures are associated with small (large) differences with the CON series. This effect is also evident if temperatures are analyzed by seasons: summer differences are much

  20. PRESBYOPIA OPTOMETRY METHOD BASED ON DIOPTER REGULATION AND CHARGE COUPLE DEVICE IMAGING TECHNOLOGY.

    Science.gov (United States)

    Zhao, Q; Wu, X X; Zhou, J; Wang, X; Liu, R F; Gao, J

    2015-01-01

    With the development of photoelectric technology and single-chip microcomputer technology, objective optometry, also known as automatic optometry, is becoming precise. This paper proposed a presbyopia optometry method based on diopter regulation and Charge Couple Device (CCD) imaging technology and, in the meantime, designed a light path that could measure the system. This method projects a test figure to the eye ground and then the reflected image from the eye ground is detected by CCD. The image is then automatically identified by computer and the far point and near point diopters are determined to calculate lens parameter. This is a fully automatic objective optometry method which eliminates subjective factors of the tested subject. Furthermore, it can acquire the lens parameter of presbyopia accurately and quickly and can be used to measure the lens parameter of hyperopia, myopia and astigmatism.

  1. Radioactive liquid wastes processing device

    International Nuclear Information System (INIS)

    Sauda, Kenzo; Koshiba, Yukihiko; Yagi, Takuro; Yamazaki, Hideki.

    1985-01-01

    Purpose: To carry out optimum photooxidizing procession following after the fluctuation in the density of organic materials in radioactive liquid wastes to thereby realize automatic remote procession. Constitution: A reaction tank is equipped with an ultraviolet lamp and an ozone dispersing means for the oxidizing treatment of organic materials in liquid wastes under the irradiation of UV rays. There are also provided organic material density measuring devices to the inlet and outlet of the reaction tank, and a control device for controlling the UV lamp power adjusting depending on the measured density. The output of the UV lamp is most conveniently adjusted by changing the applied voltage. The liquid wastes in which the radioactivity dose is reduced to a predetermined level are returned to the reaction tank by the operation of a switching valve for reprocession. The amount of the liquid wastes at the inlet is controlled depending on the measured ozone density by the adjusting valve. In this way, the amount of organic materials to be subjected to photolysis can be kept within a certain limit. (Kamimura, M.)

  2. Automatized target devices for radioisotope production at the RITs cyclotron

    International Nuclear Information System (INIS)

    Bogdanov, P.V.; Ivanov, V.V.; Karasev, B.G.

    1981-01-01

    An automation target device intended for isotope production on the internal beam of the RITs cyclotron is decribed. The target device comprises the following main units: target head, vacuum lock, charging device, transport system for bringing the target for charging; mechanism of target discharge transport device, control interlocking and signalling control system of target radiation power. The automation target device permits radioisotope production on the cyclotron in commercial scales with automation substitution of irradiated targets. The time of substitution of one of six targets makes up only 5 min. The time of charging a new group of targets to the charge device - 60 min. Contact of the personnel with irradiated targets is practically excluded and the necessity of entering the cyclotron room for maintenance of the plant is reduced to the minimum [ru

  3. Online devices and measuring systems for the automatic control of newspaper printing

    Science.gov (United States)

    Marszalec, Elzbieta A.; Heikkila, Ismo; Juhola, Helene; Lehtonen, Tapio

    1999-09-01

    The paper reviews the state-of-the-art color measuring systems used for the control of newspaper printing. The printing process requirements are specified and different off-line and on-line color quality control systems, commercially available and under development, are evaluated. Recent market trends in newspaper printing are discussed based on the survey. The study was made on information derived from: conference proceedings (TAGA, IARIGAI, SPIE and IS&T), journals (American Printer, Applied Optics), discussions with experts (GMI, QTI, HONEYWELL, TOBIAS, GretagMacbeth), IFRA Expo'98/Quality Measuring Technologies, commercial brochures, and the Internet. On the background of this review, three different measuring principles, currently, under investigation at VTT Information Technology, are described and their applicability to newspaper printing is evaluated.

  4. Automatic Task Classification via Support Vector Machine and Crowdsourcing

    Directory of Open Access Journals (Sweden)

    Hyungsik Shin

    2018-01-01

    Full Text Available Automatic task classification is a core part of personal assistant systems that are widely used in mobile devices such as smartphones and tablets. Even though many industry leaders are providing their own personal assistant services, their proprietary internals and implementations are not well known to the public. In this work, we show through real implementation and evaluation that automatic task classification can be implemented for mobile devices by using the support vector machine algorithm and crowdsourcing. To train our task classifier, we collected our training data set via crowdsourcing using the Amazon Mechanical Turk platform. Our classifier can classify a short English sentence into one of the thirty-two predefined tasks that are frequently requested while using personal mobile devices. Evaluation results show high prediction accuracy of our classifier ranging from 82% to 99%. By using large amount of crowdsourced data, we also illustrate the relationship between training data size and the prediction accuracy of our task classifier.

  5. Diagnostic accuracy of portable instrumental devices to measure sleep bruxism: a systematic literature review of polysomnographic studies.

    Science.gov (United States)

    Manfredini, D; Ahlberg, J; Castroflorio, T; Poggio, C E; Guarda-Nardini, L; Lobbezoo, F

    2014-11-01

    This study systematically reviews the sleep bruxism (SB) literature published in the MEDLINE and Scopus databases to answer the following question: What is the validity of the different portable instrumental devices that have been proposed to measure SB if compared with polysomnographic (PSG) recordings assumed as the gold standard? Four clinical studies on humans, assessing the diagnostic accuracy of portable instrumental approaches (i.e. Bitestrip, electromyography (EMG)-telemetry recordings and Bruxoff) with respect to PSG, were included in the review. Methodological shortcomings were identified by QUADAS-2 quality assessment. Findings showed contrasting results and supported only in part the validity of the described diagnostic devices with respect to PSG. The positive predictive value (PPV) of the Bitestrip device was 59-100%, with a sensitivity of 71-84·2%, whilst EMG-telemetry recordings had an unacceptable rate of false-positive findings (76·9%), counterbalanced by an almost perfect sensitivity (98·8%). The Bruxoff device had the highest accuracy values, showing an excellent agreement with PSG for both manual (area under ROC = 0·98) and automatic scoring (0·96) options as well as for the simultaneous recording of events with respect to PSG (0·89-0·91). It can be concluded that the available information on the validity of portable instrumental diagnostic approaches with respect to PSG recordings is still scarce and not solid enough to support any non-PSG technique's employ as a stand-alone diagnostic method in the research setting, with the possible exception of the Bruxoff device that needs to be further confirmed with future investigations. © 2014 John Wiley & Sons Ltd.

  6. Experiences with automatic N and P measurements of an activated sludge process in a research environment

    DEFF Research Database (Denmark)

    Isaacs, Steven Howard; Temmink, H.

    1996-01-01

    Some of the advantages of on-line automatic measurement of ammonia, nitrate and phosphate for studying activated sludge systems are pointed out with the help of examples of batch experiments. Sample taking is performed by cross-flow filtration and measurement of all three analytes is performed by...

  7. Device measures static friction of magnetic tape

    Science.gov (United States)

    Cole, P. T.

    1967-01-01

    Device measures the coefficient of static friction of magnetic tape over a range of temperatures and relative humidities. It uses a strain gage to measure the force of friction between a reference surface and the tape drawn at a constant velocity of approximately 0.0001 inch per second relative to the reference surface.

  8. Real-time precision measuring device of tree diameter growth

    Science.gov (United States)

    Guo, Mingming; Chen, Aijun; Li, Dongsheng; Liu, Nan; Yao, Jingyuan

    2016-01-01

    DBH(diameter at breast height) is an important factor to reflect of the quality of plant growth, also an important parameter indispensable in forest resources inventory and forest carbon sink, the accurate measurement of DBH or not is directly related to the research of forest resources inventory and forest carbon sink. In this paper, the principle and the mathematical model of DBH measurement device were introduced, the fixture measuring device and the hardware circuit for this tree diameter were designed, the measurement software programs were compiled, and the precision measuring device of tree diameter growth was developed. Some experiments with Australia fir were conducted. Based on experiment data, the correlations among the DBH variation of Australian fir, the environment temperature, air humility and PAR(photosynthetically active radiation) were obtained. The effects of environmental parameters (environment temperature, air humility and PAR) on tree diameter were analyzed. Experimental results show that there is a positive correlation between DBH variation of Australian fir and environment temperature, a negative correlation between DBH variation of Australian fir and air humility , so is PAR.

  9. Attacks on Mobile Phones that Use the Automatic Configuration Mechanism

    Directory of Open Access Journals (Sweden)

    A. G. Beltov

    2012-09-01

    Full Text Available The authors analyze the attacks on mobile devices that use the mechanism of an automatic configuration OMA/OTA, whose aim is listening to the Internet traffic of subscribers and the intrusion of malicious software on the user’s device, and suggest ways to protect mobile phones against such attacks.

  10. An Innovative Flow-Measuring Device: Thermocouple Boundary Layer Rake

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Wrbanek, John D.; Blaha, Charles A.

    2001-01-01

    An innovative flow-measuring device, a thermocouple boundary layer rake, was developed. The sensor detects the flow by using a thin-film thermocouple (TC) array to measure the temperature difference across a heater strip. The heater and TC arrays are microfabricated on a constant-thickness quartz strut with low heat conductivity. The device can measure the velocity profile well into the boundary layer, about 65 gm from the surface, which is almost four times closer to the surface than has been possible with the previously used total pressure tube.

  11. 30 CFR 75.320 - Air quality detectors and measurement devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air quality detectors and measurement devices... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.320 Air quality detectors and measurement devices. (a) Tests for methane shall be made by a qualified person with...

  12. Development and optimization of a device for diferencial pressure measurement

    International Nuclear Information System (INIS)

    Santarine, G.A.

    1980-01-01

    The measurements of reduced values of diferencial pressure, are studied. Several situations are described where the diferencial pressure accurate measurement is necessary in routine works in the Thermohydraulic Laboratory, as well as, the major pressure measurement devices and their respective range are studied. The development of a device for diferencial pressure measurement followed by the design development of the calibration bench covering the foreseen range, start up tests realization, optimization, calibration, performance analysis and conclusions, is showed. (Author) [pt

  13. Device for measuring the temperature of flowing hot gases

    Energy Technology Data Exchange (ETDEWEB)

    Reed, R D

    1977-05-12

    The invention pertains to a device to measure the temperature of a hot gas flowing through a closed tube. The device will have a simple and inexpensive design and avoid heat losses due to heat radiation near the thermal sensor.

  14. Miniature ingestible telemeter devices to measure deep-body temperature

    Science.gov (United States)

    Pope, J. M.; Fryer, T. B. (Inventor)

    1976-01-01

    A telemetry device comprised of a pill-size ingestible transmitter developed to obtain deep body temperature measurements of a human is described. The device has particular utility in the medical field where deep body temperatures provide an indication of general health.

  15. Algorithm for automatic analysis of electro-oculographic data.

    Science.gov (United States)

    Pettersson, Kati; Jagadeesan, Sharman; Lukander, Kristian; Henelius, Andreas; Haeggström, Edward; Müller, Kiti

    2013-10-25

    Large amounts of electro-oculographic (EOG) data, recorded during electroencephalographic (EEG) measurements, go underutilized. We present an automatic, auto-calibrating algorithm that allows efficient analysis of such data sets. The auto-calibration is based on automatic threshold value estimation. Amplitude threshold values for saccades and blinks are determined based on features in the recorded signal. The performance of the developed algorithm was tested by analyzing 4854 saccades and 213 blinks recorded in two different conditions: a task where the eye movements were controlled (saccade task) and a task with free viewing (multitask). The results were compared with results from a video-oculography (VOG) device and manually scored blinks. The algorithm achieved 93% detection sensitivity for blinks with 4% false positive rate. The detection sensitivity for horizontal saccades was between 98% and 100%, and for oblique saccades between 95% and 100%. The classification sensitivity for horizontal and large oblique saccades (10 deg) was larger than 89%, and for vertical saccades larger than 82%. The duration and peak velocities of the detected horizontal saccades were similar to those in the literature. In the multitask measurement the detection sensitivity for saccades was 97% with a 6% false positive rate. The developed algorithm enables reliable analysis of EOG data recorded both during EEG and as a separate metrics.

  16. Device to measure level in a steam drum of NPP

    International Nuclear Information System (INIS)

    Vinogradov, Yu.A.

    1988-01-01

    Gravitation-hydrostatic device for measuring coolant level in a steam drum of NPP is described. The device enables to improve the accuracy and sensitivity of measuring coolant level above and below the submerged perforated sheet of the steam drum and decrease the amount of levelling vessels in the unit by 50%. 1 fig

  17. Development of automatic facilities for ZEPHYR

    International Nuclear Information System (INIS)

    Eder, O.; Lackner, E.; Pohl, F.; Schilling, H.B.

    1982-04-01

    This concept of remotely controlled facilities for repair and maintenance tasks inside the ZEPHYR vacuum vessel uses a supporting structure to insert various types of mobile automatic devices are guided by an egg-shaped disc which is part of the supporting structure. Considerations of adapting the guiding disc to the vessel contour are included. (orig.)

  18. An open source device for operant licking in rats.

    Science.gov (United States)

    Longley, Matthew; Willis, Ethan L; Tay, Cindy X; Chen, Hao

    2017-01-01

    We created an easy-to-use device for operant licking experiments and another device that records environmental variables. Both devices use the Raspberry Pi computer to obtain data from multiple input devices (e.g., radio frequency identification tag readers, touch and motion sensors, environmental sensors) and activate output devices (e.g., LED lights, syringe pumps) as needed. Data gathered from these devices are stored locally on the computer but can be automatically transferred to a remote server via a wireless network. We tested the operant device by training rats to obtain either sucrose or water under the control of a fixed ratio, a variable ratio, or a progressive ratio reinforcement schedule. The lick data demonstrated that the device has sufficient precision and time resolution to record the fast licking behavior of rats. Data from the environment monitoring device also showed reliable measurements. By providing the source code and 3D design under an open source license, we believe these examples will stimulate innovation in behavioral studies. The source code can be found at http://github.com/chen42/openbehavior.

  19. Study of a bubble chamber's pictures automatic analyser: Coccinelle

    International Nuclear Information System (INIS)

    Jaeger, J.-J.

    1974-01-01

    The automatic scanning and measuring system ''Coccinelle'' built in the Laboratoire de Physique Corpusculaire of College de France, is specially made for the pictures of the new large bubble chambers like BEBC and Mirabelle. This device uses the spot of a high precision cathode ray tube for the analysis of the picture according to a scanning window. The signal of a photomultiplier located behind the picture gives, after processing, the useful information in the form of coordinates of the analyzed points. Electronics, connected to a computer, generates the movements of the spot, the backward and forward movement of the films, and gives the right information for the programs of geometrical reconstruction of the tracks. The use of the device is based upon the collaboration of a programmed automaton and a human operator that have conversational facilities: TV display, light-pen and function keyboard. Beyond a detailed description of the whole device, this thesis insists especially on the following electronic parts: sweep generation of the spot, photomultiplier signal processing [fr

  20. Matching Automatic Gain Control Across Devices in Bimodal Cochlear Implant Users.

    Science.gov (United States)

    Veugen, Lidwien C E; Chalupper, Josef; Snik, Ad F M; Opstal, A John van; Mens, Lucas H M

    2016-01-01

    The purpose of this study was to improve bimodal benefit in listeners using a cochlear implant (CI) and a hearing aid (HA) in contralateral ears, by matching the time constants and the number of compression channels of the automatic gain control (AGC) of the HA to the CI. Equivalent AGC was hypothesized to support a balanced loudness for dynamically changing signals like speech and improve bimodal benefit for speech understanding in quiet and with noise presented from the side(s) at 90 degree. Fifteen subjects participated in the study, all using the same Advanced Bionics Harmony CI processor and HA (Phonak Naida S IX UP). In a 3-visit crossover design with 4 weeks between sessions, performance was measured using a HA with a standard AGC (syllabic multichannel compression with 1 ms attack time and 50 ms release time) or an AGC that was adjusted to match that of the CI processor (dual AGC broadband compression, 3 and 240 msec attack time, 80 and 1500 msec release time). In all devices, the AGC was activated above the threshold of 63 dB SPL. The authors balanced loudness across the devices for soft and loud input sounds in 3 frequency bands (0 to 548, 548 to 1000, and >1000 Hz). Speech understanding was tested in free field in quiet and in noise for three spatial speaker configurations, with target speech always presented from the front. Single-talker noise was either presented from the CI side or the HA side, or uncorrelated stationary speech-weighted noise or single-talker noise was presented from both sides. Questionnaires were administered to assess differences in perception between the two bimodal fittings. Significant bimodal benefit over the CI alone was only found for the AGC-matched HA for the speech tests with single-talker noise. Compared with the standard HA, matched AGC characteristics significantly improved speech understanding in single-talker noise by 1.9 dB when noise was presented from the HA side. AGC matching increased bimodal benefit

  1. Control device for start-up of reactor depressurization system

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Saito, Minoru; Oda, Shingo; Miura, Satoshi; Hashimoto, Koji; Tate, Hitoshi; Fujii, Kazunobu

    1998-01-01

    The present invention concerns are emergency reactor core cooling system (ECCS) of a BWR type reactor and provides a control device for start-up of an automatic depressurization system. Namely, the device has an object of preventing erroneous opening of a main steam escape safety value when testing a start-up signal circuit of an automatic depressurization system for testing the automatic depressurization system. A start-up signal circuit receives both signals of a reactor container pressure high signal and a reactor pressure vessel water level low signal and outputs an automatic start-up signal for compulsorily opening a main steam escape safety valve automatically. A test switch having a self-holding circuit is disposed to a central control chamber. A test signal circuit is disposed for preventing transfer of an erroneous start-up signal to the main steam escape safety valve due to a simulation signal during output test signals by the test switch. (I.S.)

  2. A tape-controlled remote automatic diameter measurement machine

    International Nuclear Information System (INIS)

    Jennison, W.; Salmon, A.M.

    1978-01-01

    The machine is designed for the automatic measurement of fuel pins after irradiation in the fast reactors and is a modified version of a machine which has been in use for several years. These modifications consist of mechanical improvements and solid state control circuitry but the design criteria are unchanged. Irradiated fuel pins with diameters up to 0.875 in. are measured at fixed axial positions and angular intervals. Axial stepping of either 1 cm or 1 in. with a standard deviation of 5 x 10 -4 in. and angular rotation by multiples of 18 0 with a non-cumulative error of 1 0 can be selected. Data on axial position to 0.1 in. or 0.1 cm and fuel element diameter to 5 x 10 -5 in. are both punched and printed out for computer evaluation. The standard deviation of a single measurement on cylindrical specimens with an eccentricity of up to at least 0.1 in. should be no worse than 1 x 10 -4 in. No operator attention is required after the pin is positioned in the machine and 40 sets of 10 diameter readings at 36 0 intervals can be performed in an hour. Switches can be set between 1 and 99 to terminate an examination when power is switched off with the machine in its rest position. (author)

  3. Automatic Integration of IoT Devices

    OpenAIRE

    Pêgo, Pedro Ruben Januário

    2016-01-01

    During the last years a new concept has gained prominence in the technology world. With an increasingly dominant role in our days, Internet of Things (IoT) is a technological revolution that is changing our lives. The imagination is the limit for the new devices that may appear in the market. This phenomenon is derived from both, the technological evolution and the growing acceptance of this type of products in our social life. Faced with a fast growth, an increasing diversity ...

  4. an automatic safety control for immersion water heater

    African Journals Online (AJOL)

    NIJOTECH

    An important source of concern with this appliance is the frequent possibility of outbreak of fire due to ... The safety condition is achieved by incorporating a device, which automatically .... The relay-driving network is indicated in the circuit of ...

  5. Gas processing device

    International Nuclear Information System (INIS)

    Kobayashi, Yoshihiro; Seki, Eiji.

    1991-01-01

    State of electric discharge is detected based on a gas pressure in a sealed container and a discharging current flowing between both of electrodes. When electric arc discharges occur, introduction of gases to be processed is stopped and a voltage applied to both of the electrodes is interrupted. Then, when the gas pressure in the sealed container is lowered to a predetermined value, a power source voltage is applied again to both of the electrodes to recover glow discharges, and the introduction of the gas to be processed is started. With such steps, even if electric arc discharges occur, they are eliminated automatically and, accordingly, normal glow discharges can be recovered, to prevent failures of the device due to electric arc discharges. The glow discharges are recovered automatically without stopping the operation of the gas processing device, and gas injection and solidification processing can be conducted continuously and stably. (T.M.)

  6. Children’s Behavioral Pain Cues: Implicit Automaticity and Control Dimensions in Observational Measures

    Directory of Open Access Journals (Sweden)

    Kamal Kaur Sekhon

    2017-01-01

    Full Text Available Some pain behaviors appear to be automatic, reflexive manifestations of pain, whereas others present as voluntarily controlled. This project examined whether this distinction would characterize pain cues used in observational pain measures for children aged 4–12. To develop a comprehensive list of cues, a systematic literature search of studies describing development of children’s observational pain assessment tools was conducted using MEDLINE, PsycINFO, and Web of Science. Twenty-one articles satisfied the criteria. A total of 66 nonredundant pain behavior items were identified. To determine whether items would be perceived as automatic or controlled, 277 research participants rated each on multiple scales associated with the distinction. Factor analyses yielded three major factors: the “Automatic” factor included items related to facial expression, paralinguistics, and consolability; the “Controlled” factor included items related to intentional movements, verbalizations, and social actions; and the “Ambiguous” factor included items related to voluntary facial expressions. Pain behaviors in observational pain scales for children can be characterized as automatic, controlled, and ambiguous, supporting a dual-processing, neuroregulatory model of pain expression. These dimensions would be expected to influence judgments of the nature and severity of pain being experienced and the extent to which the child is attempting to control the social environment.

  7. 78 FR 49272 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-08-13

    ... into two types: (1) Devices that provide automatic chest compressions at a fixed compression rate and... circuit is comprised of multiple device types, including, but not limited to, an oxygenator, blood pump... submit a brief statement of the general nature of the evidence or arguments they wish to present, the...

  8. Automatic track counting with an optic RAM-based instrument

    International Nuclear Information System (INIS)

    Staderini, E.M.; Castellano, Alfredo

    1986-01-01

    A new image sensor, the optic RAM, is now used in a microprocessor controlled instrument to read and digitize images from CR39 solid state nuclear track detectors. The system performs image analysis, filtering, tracks counting and evaluation in a fully automatic way, not requiring an optic microscope, nor photographic or television devices. The proposed system is a very compact and low power device. (author)

  9. Development of portable and automatic smear sampler for measuring surface contamination

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated.

  10. Development of portable and automatic smear sampler for measuring surface contamination

    International Nuclear Information System (INIS)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W.

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated

  11. Automatic monitoring of isolation state in low-voltage distribution network

    Directory of Open Access Journals (Sweden)

    Людмила Олександрівна Добровольська

    2017-06-01

    Full Text Available The article discusses the possibility of using the proposed functional isolation monitoring circuit with an additional high-frequency signal of 3500 Hz, introduced into the power network, which allows real-time detection of isolation leakage current not exceeding 8,5 mA. To check the isolation state it was decided to control leakage currents. To do this it is proposed to use the current control device developed by the authors that provides measurement of the currents in the lines and used by consumers. The device makes it possible to determine the magnitude and locations of the unauthorized taking away the power and to transmit the data to the control station wirelessly. It is proposed to extend the functionality of the device by automatically measuring leakage currents when monitoring the isolation state if current exceeds the permissible limits. This can be achieved by introducing a current control device of frequency-dependent selective amplifier of sinusoidal leakage currents that solves the problem of frequency separation and allows the isolation state control without disconnecting users from the network. Early detection and removal of defects of isolation before they become interfacial short circuits and dead ground short circuits will prevent the occurrence of dangerous situations, increase the reliability and service life of electrical networks and ensure uninterrupted power supply of consumers with electricity

  12. Automatic film loader for X-ray spot film device

    International Nuclear Information System (INIS)

    1975-01-01

    A light tight tunnel extends over the top of a diagnostic X-ray table. A film cassette is mounted for reciprocating in the tunnel between an X-ray exposure position and a position in which the cassette is unloaded or loaded with film automatically. Unexposed films are dispensed one at a time into the cassette from a feed magazine at one end of the tunnel. After exposure, the film is ejected from the cassette into a receiving magazine at the same end of the tunnel. (Auth.)

  13. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults.

    Science.gov (United States)

    Altunkan, Sekip; Ilman, Nevzat; Kayatürk, Nur; Altunkan, Erkan

    2007-08-01

    Electronic blood pressure (BP) measurement devices are the preferred choice of patients owing to their user-friendly nature; however, there is a requirement to investigate the accuracy and reliability of these devices. The objective of this study is to evaluate the accuracy of the Omron M6 upper-arm BP device against the mercury sphygmomanometer in adults and obese adults according to the International Protocol criteria. One hundred and twenty-one patients, older than 30 years of age, were studied and classified on the basis of the range of the International Protocol. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. A total of 33 participants were selected for each validation study. During the validation study, 99 measurements were performed on 33 participants for comparison. The first phase was performed on 15 participants, and if the device passed this phase, 18 more participants were selected. Having a two-fold purpose, this study was conducted on both adult and obese adult patients. Mean discrepancies and standard deviations of the monitor-mercury sphygmomanometer were 1.1+/-4.0 mmHg for systolic BP (SBP) and -0.5+/-3.5 mmHg for diastolic BP (DBP) in the adult group. The device passed phase 1 in 15 participants. In phase 2.1, out of a total of 99 comparisons, 88, 96, and 97 for SBP, and 88, 98, and 99 for DBP were M6 automatic monitor, which measures BP at the upper arm, produced results in accordance with the criteria of phases 2.1 and 2.2 in both SBP and DBP, when applied to adults and to obese adults. It was concluded that the Omron M6 device, which measures BP at the upper arm, was deemed to be in accordance with the International Protocol criteria and can be recommended for use by adults and obese adults.

  14. Voice Quality Measuring Setup with Automatic Voice over IP Call Generator and Lawful Interception Packet Analyzer

    Directory of Open Access Journals (Sweden)

    PLEVA Matus

    Full Text Available This paper describes the packet measuring laboratory setup, which could be used also for lawful interception applications, using professional packet analyzer, Voice over IP call generator, free call server (Asterisk linux setup and appropriate software and hardware described below. This setup was used for measuring the quality of the automatically generated VoIP calls under stressed network conditions, when the call manager server was flooded with high bandwidth traffic, near the bandwidth limit of the connected switch. The call generator realizes 30 calls simultaneously and the packet capturer & analyzercould decode the VoIP traffic, extract RTP session data, automatically analyze the voice quality using standardized MOS (Mean Opinion Score values and describe also the source of the voice degradation (jitter, packet loss, codec, delay, etc..

  15. Accuracy of an improved device for remote measuring of tree-trunk diameters

    International Nuclear Information System (INIS)

    Matsushita, T.; Kato, S.; Komiyama, A.

    2000-01-01

    For measuring the diameters of tree trunks from a distant position, a recent device using a laser beam was developed by Kantou. We improved this device to serve our own practical purposes. The improved device consists of a 1-m-long metal caliper and a small telescope sliding smoothly onto it. Using the cross hairs in the scope, one can measure both edges of an object on the caliper and calculate its length. The laser beam is used just for guiding the telescopic sights to the correct positions on the object. In this study, the accuracy of this new device was examined by measuring objects of differing lengths, the distance from the object, and the angle of elevation to the object. Since each result of the experiment predicted absolute errors of measurement of less than 3 mm, this new device will be suitable for the measurement of trunk diameters in the field

  16. Automatic weld torch guidance control system

    Science.gov (United States)

    Smaith, H. E.; Wall, W. A.; Burns, M. R., Jr.

    1982-01-01

    A highly reliable, fully digital, closed circuit television optical, type automatic weld seam tracking control system was developed. This automatic tracking equipment is used to reduce weld tooling costs and increase overall automatic welding reliability. The system utilizes a charge injection device digital camera which as 60,512 inidividual pixels as the light sensing elements. Through conventional scanning means, each pixel in the focal plane is sequentially scanned, the light level signal digitized, and an 8-bit word transmitted to scratch pad memory. From memory, the microprocessor performs an analysis of the digital signal and computes the tracking error. Lastly, the corrective signal is transmitted to a cross seam actuator digital drive motor controller to complete the closed loop, feedback, tracking system. This weld seam tracking control system is capable of a tracking accuracy of + or - 0.2 mm, or better. As configured, the system is applicable to square butt, V-groove, and lap joint weldments.

  17. Exploration of Uninitialized Configuration Memory Space for Intrinsic Identification of Xilinx Virtex-5 FPGA Devices

    Directory of Open Access Journals (Sweden)

    Oliver Sander

    2012-01-01

    Full Text Available SRAM-based fingerprinting uses deviations in power-up behaviour caused by the CMOS fabrication process to identify distinct devices. This method is a promising technique for unique identification of physical devices. In the case of SRAM-based hardware reconfigurable devices such as FPGAs, the integrated SRAM cells are often initialized automatically at power-up, sweeping potential identification data. We demonstrate an approach to utilize unused parts of configuration memory space for device identification. Based on a total of over 200,000 measurements on nine Xilinx Virtex-5 FPGAs, we show that the retrieved values have promising properties with respect to consistency on one device, variety between different devices, and stability considering temperature variation and aging.

  18. Small Device For Short-Range Antenna Measurements Using Optics

    DEFF Research Database (Denmark)

    Yanakiev, Boyan Radkov; Nielsen, Jesper Ødum; Christensen, Morten

    2011-01-01

    This paper gives a practical solution for implementing an antenna radiation pattern measurement device using optical fibers. It is suitable for anechoic chambers as well as short range channel sounding. The device is optimized for small size and provides a cheap and easy way to make optical antenna...

  19. Automatized system of radioactive material analysis

    International Nuclear Information System (INIS)

    Pchelkin, V.A.; Sviderskij, M.F.; Litvinov, V.A.; Lavrikov, S.A.

    1979-01-01

    An automatized system has been developed for the identification of substance, element and isotope content of radioactive materials on the basis of data obtained for studying physical-chemical properties of substances (with the help of atomic-absorption spectrometers, infrared spectrometer, mass-spectrometer, derivatograph etc.). The system is based on the following principles: independent operation of each device; a possibility of increasing the number of physical instruments and devices; modular properties of engineering and computer means; modular properties and standardization of mathematical equipment, high reliability of the system; continuity of programming languages; a possibility of controlling the devices with the help of high-level language, typification of the system; simple and easy service; low cost. Block-diagram of the system is given

  20. SHORT COMMUNICATION: Time measurement device with four femtosecond stability

    Science.gov (United States)

    Panek, Petr; Prochazka, Ivan; Kodet, Jan

    2010-10-01

    We present the experimental results of extremely precise timing in the sense of time-of-arrival measurements in a local time scale. The timing device designed and constructed in our laboratory is based on a new concept using a surface acoustic wave filter as a time interpolator. Construction of the device is briefly described. The experiments described were focused on evaluating the timing precision and stability. Low-jitter test pulses with a repetition frequency of 763 Hz were generated synchronously to the local time base and their times of arrival were measured. The resulting precision of a single measurement was typically 900 fs RMS, and a timing stability TDEV of 4 fs was achieved for time intervals in the range from 300 s to 2 h. To our knowledge this is the best value reported to date for the stability of a timing device. The experimental results are discussed and possible improvements are proposed.

  1. 30 CFR 75.523-3 - Automatic emergency-parking brakes.

    Science.gov (United States)

    2010-07-01

    ... immediately by the emergency deenergization device required by 30 CFR 75.523-1 and -75.523-2; (2) Engage automatically within 5.0 seconds when the equipment is deenergized; (3) Safely bring the equipment when fully...

  2. Improving the accuracy of smart devices to measure noise exposure.

    Science.gov (United States)

    Roberts, Benjamin; Kardous, Chucri; Neitzel, Richard

    2016-11-01

    Occupational noise exposure is one of the most frequent hazards present in the workplace; up to 22 million workers have potentially hazardous noise exposures in the U.S. As a result, noise-induced hearing loss is one of the most common occupational injuries in the U.S. Workers in manufacturing, construction, and the military are at the highest risk for hearing loss. Despite the large number of people exposed to high levels of noise at work, many occupations have not been adequately evaluated for noise exposure. The objective of this experiment was to investigate whether or not iOS smartphones and other smart devices (Apple iPhones and iPods) could be used as reliable instruments to measure noise exposures. For this experiment three different types of microphones were tested with a single model of iPod and three generations of iPhones: the internal microphones on the device, a low-end lapel microphone, and a high-end lapel microphone marketed as being compliant with the International Electrotechnical Commission's (IEC) standard for a Class 2-microphone. All possible combinations of microphones and noise measurement applications were tested in a controlled environment using several different levels of pink noise ranging from 60-100 dBA. Results were compared to simultaneous measurements made using a Type 1 sound level measurement system. Analysis of variance and Tukey's honest significant difference (HSD) test were used to determine if the results differed by microphone or noise measurement application. Levels measured with external microphones combined with certain noise measurement applications did not differ significantly from levels measured with the Type 1 sound measurement system. Results showed that it may be possible to use iOS smartphones and smart devices, with specific combinations of measurement applications and calibrated external microphones, to collect reliable, occupational noise exposure data under certain conditions and within the limitations of the

  3. Test device for measuring permeability of a barrier material

    Science.gov (United States)

    Reese, Matthew; Dameron, Arrelaine; Kempe, Michael

    2014-03-04

    A test device for measuring permeability of a barrier material. An exemplary device comprises a test card having a thin-film conductor-pattern formed thereon and an edge seal which seals the test card to the barrier material. Another exemplary embodiment is an electrical calcium test device comprising: a test card an impermeable spacer, an edge seal which seals the test card to the spacer and an edge seal which seals the spacer to the barrier material.

  4. Securing IoT Devices at CERN

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    CERN has more than 1000 Internet of Things (IoT) devices, which are connected to the office network. We have been doing the research to find all vulnerable IoT devices in CERN and mitigated them. We are currently working on detecting IoT devices automatically and, moreover, identifying the manufacturer, model and the running firmware version. This will help the CERN Computer Security Team to spot vulnerable devices and to show the security risks associated with them.

  5. Automatic trajectory measurement of large numbers of crowded objects

    Science.gov (United States)

    Li, Hui; Liu, Ye; Chen, Yan Qiu

    2013-06-01

    Complex motion patterns of natural systems, such as fish schools, bird flocks, and cell groups, have attracted great attention from scientists for years. Trajectory measurement of individuals is vital for quantitative and high-throughput study of their collective behaviors. However, such data are rare mainly due to the challenges of detection and tracking of large numbers of objects with similar visual features and frequent occlusions. We present an automatic and effective framework to measure trajectories of large numbers of crowded oval-shaped objects, such as fish and cells. We first use a novel dual ellipse locator to detect the coarse position of each individual and then propose a variance minimization active contour method to obtain the optimal segmentation results. For tracking, cost matrix of assignment between consecutive frames is trainable via a random forest classifier with many spatial, texture, and shape features. The optimal trajectories are found for the whole image sequence by solving two linear assignment problems. We evaluate the proposed method on many challenging data sets.

  6. Automatic identification of NDA measured items: Use of E-tags

    International Nuclear Information System (INIS)

    Chitumbo, K.; Olsen, R.; Hatcher, C.R.; Kadner, S.P.

    1995-01-01

    This paper describes how electronic identification devices or E-tags could reduce the time spent by LAEA inspectors making nondestructive assay (NDA) measurements. As one example, the use of E-tags with a high-level neutron coincidence counter (HLNC) is discussed in detail. Sections of the paper include inspection procedures, system description, software, and future plans. Mounting of E-tabs, modifications to the HLNC, and the use of tamper indicating devices are also discussed. The technology appears to have wide application to different types of nuclear facilities and inspections and could significantly change NDA inspection procedures

  7. A Laser-Based Measuring System for Online Quality Control of Car Engine Block

    Directory of Open Access Journals (Sweden)

    Xing-Qiang Li

    2016-11-01

    Full Text Available For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs, which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments.

  8. Process control device

    International Nuclear Information System (INIS)

    Hayashi, Toshifumi; Kobayashi, Hiroshi.

    1994-01-01

    A process control device comprises a memory device for memorizing a plant operation target, a plant state or a state of equipments related with each other as control data, a read-only memory device for storing programs, a plant instrumentation control device or other process control devices, an input/output device for performing input/output with an operator, and a processing device which conducts processing in accordance with the program and sends a control demand or a display demand to the input/output device. The program reads out control data relative to a predetermined operation target, compares and verify them with actual values to read out control data to be a practice premise condition which is further to be a practice premise condition if necessary, thereby automatically controlling the plant or requiring or displaying input. Practice presuming conditions for the operation target can be examined succesively in accordance with the program without constituting complicated logical figures and AND/OR graphs. (N.H.)

  9. Full-automatic measurement of the ELSA working point with 'EPOS'

    International Nuclear Information System (INIS)

    Goetz, T.

    1990-11-01

    Two years ago the Bonn Electron Stretcher Accelerator ELSA came into operation. Although the control system proved to be a valuable tool for operating the machine, there did not exist any high level application software dealing with beam diagnostics, orbit measurement and closed orbit correction. To cover these main fields of machine physics, a new program 'EPOS' was implemented on top of the existing control system. EPOS integrates data aquisition, beam diagnostics, digitial signal processing and automation of measurement and control in one interactive environment. The system is equipped with a new, easy to use programming language for machine physics and data analysis. EPOS is based on X-windows and can generate high quality diagrams and printouts for all kinds of measured or simulated data. The design and implementation of EPOS is sketched in this document. Its functionality is demonstrated by performing automatic measurements of the ELSA tune with high precision. By using a special method for error correction, the obtained precision can be increased by approximately two orders of magnitude, compared to standard Fourier analysis techniques. The resulting tune values for standard ELSA operating modes are discussed in detail. (orig.) [de

  10. Reactor power measuring device

    International Nuclear Information System (INIS)

    Izumi, Mikio; Sano, Yuji; Seki, Eiji; Yoshida, Toshifumi; Ito, Toshiaki.

    1993-01-01

    The present invention provides a self-powered long detector having a sensitivity over the entire length of a reactor core as an entire control rod withdrawal range of a BWR type reactor, and a reactor power measuring device using a gamma ray thermometer which scarcely causes sensitivity degradation. That is, a hollow protection pipe is disposed passing through the reactor core from the outside of a reactor pressure vessel. The self-powered long detectors and the gamma ray thermometers are inserted and installed in the protection pipe. An average reactor power in an axial direction of the reactor relative to a certain position in the horizontal cross section of the reactor core is determined based on the power of the self-powered long detector over the entire length of the reactor core. Since the response of the self-powered detector relative to a local power change is rapid, the output is used as an input signal to a safety protection device of the reactor core. Further, a gamma ray thermometer secured in the reactor and having scarce sensitivity degradation is used instead of an incore travelling neutron monitor used for relative calibration of an existent neutron monitor secured in the reactor. (I.S.)

  11. Improvement of the exponential experiment system for the automatical and accurate measurement of the exponential decay constant

    International Nuclear Information System (INIS)

    Shin, Hee Sung; Jang, Ji Woon; Lee, Yoon Hee; Hwang, Yong Hwa; Kim, Ho Dong

    2004-01-01

    The previous exponential experiment system has been improved for the automatical and accurate axial movement of the neutron source and detector with attaching the automatical control system which consists of a Programmable Logical Controller(PLC) and a stepping motor set. The automatic control program which controls MCA and PLC consistently has been also developed on the basis of GENIE 2000 library. The exponential experiments have been carried out for Kori 1 unit spent fuel assemblies, C14, J14 and G23, and Kori 2 unit spent fuel assembly, J44, using the improved systematical measurement system. As the results, the average exponential decay constants for 4 assemblies are determined to be 0.1302, 0.1267, 0.1247, and 0.1210, respectively, with the application of poisson regression

  12. Trends of progress in medical technics as far as automatization is concerned

    Energy Technology Data Exchange (ETDEWEB)

    Agoston, M [Medicor Muevek, Budapest (Hungary)

    1978-09-01

    Modernization of medical treatment is developing to the direction of establishing big hospitals and policlinics. Highly productive automatic equipments give possibilities for performing the mass examinations with high efficiency. Still the X-ray instruments form the most valuable and indispensable device group. One direction to develop the automatization of these machines is to achieve the best X-ray exposure. The relatively slow but continuous spreading of isotope diagnostic instruments has been connected with a number of results in automatization, too. In the field of sterilization bactericid materials, gas- and ray sterilizing methods, as well as combined systems become used. Automatization has a strong influence on the domain of epidemiology as well.

  13. Measuring of moisture content in biofuel; Fukthaltsmaetning av biobraensle

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Lars; Njurell, Rolf; Ehleskog, Rickard [AaF Energikonsult AB, Stockholm (Sweden)

    2002-04-01

    Direct determination of the moisture content, i.e. analysis of the fuel, is the most dominating moisture measuring method of today, and is usually done manually by weighing and drying a sample. By measuring on the exhaust gases the moisture content is determined indirect. This method is based upon the fact that there is a relation between the moisture content in the fuel and in the exhaust gases. This is an alternative that is only considered briefly in this report. Acceptance test of the fuel today takes place in several ways. The methods vary from advanced automatic mechanical devices to manually taken tests made by the driver him self. In the simplest case when the plant only has one fuel supplier, deduction is maid against the amount of produced energy. There are no systems today that can automatically take tests for continuous measuring. This project aims to find methods that are practical for direct, automatic and continuous measurement of the moisture content for the following applications: Moisture determination of fuel supplies, acceptance test. Moisture determination for combustion control in furnaces and boilers. The possibilities to automate the sampling are discussed in detail, at which important background information concerning the handling problems associated with the point of measuring is illustrated. The measurement techniques that are described more in detail are NIR (Near Infra Red), radar technique, microwave technique, radio frequency scan, radioactive technique, double energy X-ray and some combinations of these techniques. In the report, suppliers of interesting instruments are presented. The fundamental technical demands and the basis that should be included in a specification of a measuring device are gathered. Our appraisal is that a sequel to this project should be concentrated on the following main issues: Automatic acceptance test: The measuring is suggested to be done with a test probe direct in the incoming batch. The most suited

  14. Automatic measurement of cusps in 2.5D dental images

    Science.gov (United States)

    Wolf, Mattias; Paulus, Dietrich W.; Niemann, Heinrich

    1996-01-01

    Automatic reconstruction of occlusal surfaces of teeth is an application which might become more and more urgent due to the toxicity of amalgam. Modern dental chairside equipment is currently restricted to the production of inlays. The automatic reconstruction of the occlusal surface is presently not possible. For manufacturing an occlusal surface it is required to extract features from which it is possible to reconstruct destroyed teeth. In this paper, we demonstrate how intact upper molars can be automatically extracted in dental range and intensity images. After normalization of the 3D location, the sizes of the cusps are detected and the distances between them are calculated. In the presented approach, the detection of the upper molar is based on a knowledge-based segmentation which includes anatomic knowledge. After the segmentation of the interesting tooth the central fossa is calculated. The normalization of the spatial location is archieved by aligning the detected fossa with a reference axis. After searching the cusp tips in the range image the image is resized. The methods have been successfully tested on 60 images. The results have been compared with the results of a dentist's evaluation on a sample of 20 images. The results will be further used for automatic production of tooth inlays.

  15. Feedwater control method and device therefor

    International Nuclear Information System (INIS)

    Nakahara, Mitsugu; Ichikawa, Yoshiaki; Ishii, Yoshikazu; Suzuki, Katsuyuki; Tanikawa, Naoshi; Mizuki, Fumio.

    1997-01-01

    The present invention provides a method of and a device for easily changing the constitution of feedwater systems without causing change in the water level of a reactor even when a plurality of feedwater systems have imbalance points. Namely, a feedwater control device comprises at least two feedwater systems capable of feeding water to tanks independently respectively and a controller capable of controlling water level in the tanks by controlling these feedwater systems. There is disposed a means for outputting gradually increasing driving signals to other feedwater systems, when the water level controller automatically controls one of the feedwater systems. There is also disposed a means for switching from automatic control for one of the feedwater systems to automatic control for the other feedwater system by a water level controller when the other feedwater system is in a stable operation region. As a result, entire feedwater flow rate is not temporarily changed and the water level in the tanks can be maintained constant. (N.H.)

  16. An automatic energy-saving and thermal monitoring/controlling system for a pond

    Directory of Open Access Journals (Sweden)

    Cheng Ching-Chien

    2017-01-01

    Full Text Available Because of low temperatures and oxygen in cold water, fish will die when cold currents arrive. This will cause tremendous loss of money. In order reduce the cooling of the pond, an automatic thermal detecting and cold-roofing system using a wind-proofing device, heaters, and thermal detectors is proposed. To reduce heat loss due to thermal convection above the pond surface, a motor-driven wind-proofing device automatically controlled by a PLC controller is adopted. Here, the wind-proofing device, thermal detectors, and heating system are connected to the PLC controller. The PLC will also be connected to the PC interface. The temperature thresholds used to trigger the heater and the wind proofing device can be set at the PC interface. Two options for manipulating the heating and the automatic heating can be selected. The related wind-proofing area and the number of heaters will be determined according to the current temperature. Moreover, the PLC can be wirelessly connected to the server PC in the control room. The pond keeper can monitor everything online and control the pond water's temperature. With this, the problem of fish dying in a cold wave can be solved. Consequently, to reduce the electrical exhaust when heating up the pond water, green energy, solar energy and wind energy, is used.

  17. Shaping electromagnetic waves using software-automatically-designed metasurfaces.

    Science.gov (United States)

    Zhang, Qian; Wan, Xiang; Liu, Shuo; Yuan Yin, Jia; Zhang, Lei; Jun Cui, Tie

    2017-06-15

    We present a fully digital procedure of designing reflective coding metasurfaces to shape reflected electromagnetic waves. The design procedure is completely automatic, controlled by a personal computer. In details, the macro coding units of metasurface are automatically divided into several types (e.g. two types for 1-bit coding, four types for 2-bit coding, etc.), and each type of the macro coding units is formed by discretely random arrangement of micro coding units. By combining an optimization algorithm and commercial electromagnetic software, the digital patterns of the macro coding units are optimized to possess constant phase difference for the reflected waves. The apertures of the designed reflective metasurfaces are formed by arranging the macro coding units with certain coding sequence. To experimentally verify the performance, a coding metasurface is fabricated by automatically designing two digital 1-bit unit cells, which are arranged in array to constitute a periodic coding metasurface to generate the required four-beam radiations with specific directions. Two complicated functional metasurfaces with circularly- and elliptically-shaped radiation beams are realized by automatically designing 4-bit macro coding units, showing excellent performance of the automatic designs by software. The proposed method provides a smart tool to realize various functional devices and systems automatically.

  18. Regulation and Measurement of the Heat Generated by Automatic Tooth Preparation in a Confined Space.

    Science.gov (United States)

    Yuan, Fusong; Zheng, Jianqiao; Sun, Yuchun; Wang, Yong; Lyu, Peijun

    2017-06-01

    The aim of this study was to assess and regulate heat generation in the dental pulp cavity and circumambient temperature around a tooth during laser ablation with a femtosecond laser in a confined space. The automatic tooth preparing technique is one of the traditional oral clinical technology innovations. In this technique, a robot controlled an ultrashort pulse laser to automatically complete the three-dimensional teeth preparing in a confined space. The temperature control is the main measure for protecting the tooth nerve. Ten tooth specimens were irradiated with a femtosecond laser controlled by a robot in a confined space to generate 10 teeth preparation. During the process, four thermocouple sensors were used to record the pulp cavity and circumambient environment temperatures with or without air cooling. A statistical analysis of the temperatures was performed between the conditions with and without air cooling (p heat generated in the pulp cavity was lower than the threshold for dental pulp damage. These results indicate that femtosecond laser ablation with air cooling might be an appropriate method for automatic tooth preparing.

  19. Design and development of a device to measure the deformities of clubfoot.

    Science.gov (United States)

    Khas, Kanwaljit S; Pandey, Pulak M; Ray, Alok R

    2015-03-01

    Clubfoot describes a range of foot abnormalities usually present at birth, in which the foot of a baby is twisted out of shape or position. In order to develop an effective treatment plan for clubfoot and/or assess the extent to which existing interventions are successful, medical practitioners need to be able to accurately measure the nature and extent of the deformity. This is typically performed using a goniometer. However, this device is only able to measure one dimension at a time. As such, a complete assessment of the condition of a foot can be extremely burdensome and time-consuming. This article describes a new device that can quickly and efficiently take several measurements on feet of various sizes and shapes. The use of this device was verified by measuring the deformities of real clubfeet. A silicone rubber clubfoot model was also used in this study to clearly illustrate the effectiveness with which the proposed device can measure the various deformities of clubfoot. It is envisaged that the use of this device will significantly reduce the time and effort orthopedists require to measure clubfoot deformities and develop and assess treatment plans. © IMechE 2015.

  20. An instrument for measurement of 125I with automatic efficiency correction

    International Nuclear Information System (INIS)

    Holford, R.M.

    1979-10-01

    Counting efficiencies for 125 I are often uncertain because of self-absorption of the low-energy radiation. A special purpose instrument, AEP-5285, has been designed to simplify the measurement of 125 I activities using a known technique in which the observed counting rate is compensated for self-absorption and any other uncertainties in the counting efficiency by making use of the coicidence properties of the radiation. The instrument contains pulse amplifiers, discriminators to define the energy regions of interest, and operational amplifier circuits to perform the necessary calculations automatically, and it displays an estimate of the source activity in becquerels. (auth)

  1. Significance of coupling device for vessel anastomosis in esophageal reconstruction.

    Science.gov (United States)

    Watanabe, Y; Horiuchi, A; Yamamoto, Y; Kikkawa, H; Kusunose, H; Sugishita, H; Sato, K; Yoshida, M; Yukumi, S; Kawachi, K

    2005-01-01

    To prevent an anastomotic failure due to impaired blood supply, several trials have been performed such as preoperative ischemic conditioning by transarterial embolization of the left gastric, right gastric and splenic arteries or microvascular anastomosis. We assess the significance of an automatic anastomotic coupling device for vessel anastomosis, which we have continuously utilized, to simplify the task and shorten the anastomotic time since March 1999. 8 patients who underwent venous anastomosis by an automatic anastomotic coupling device were evaluated for the time of anastomosis, total ischemic time and outcomes. Venous anastomosis was completed within 5 minutes on average. Microscopic arterial anastomosis by hand took 35 minutes on average. For gastric tube reconstruction, venous anastomosis by an automatic coupling device took only 5 minutes. The top of the gastric tube showed congestion before venous anastomosis, but rapidly recovered from it after anastomosis. Postoperative endoscopic observation of the mucosal color of the replaced intestine or gastric tube was started 3 days after surgery and revealed no ischemia or congestion. The postoperative course was uneventful except one case suffering from pneumonia but leakage was not observed in any case. An automatic anastomotic coupling device can perform an easy and reliable vascular anastomosis for patients who undergo esophageal reconstruction. The device may shorten the operating time and consequently the ischemic time of the gastric tube or jejunal or colonic graft, which in turn may lead to a decrease of complications.

  2. Semi-automatic quantitative measurements of intracranial internal carotid artery stenosis and calcification using CT angiography

    International Nuclear Information System (INIS)

    Bleeker, Leslie; Berg, Rene van den; Majoie, Charles B.; Marquering, Henk A.; Nederkoorn, Paul J.

    2012-01-01

    Intracranial carotid artery atherosclerotic disease is an independent predictor for recurrent stroke. However, its quantitative assessment is not routinely performed in clinical practice. In this diagnostic study, we present and evaluate a novel semi-automatic application to quantitatively measure intracranial internal carotid artery (ICA) degree of stenosis and calcium volume in CT angiography (CTA) images. In this retrospective study involving CTA images of 88 consecutive patients, intracranial ICA stenosis was quantitatively measured by two independent observers. Stenoses were categorized with cutoff values of 30% and 50%. The calcification in the intracranial ICA was qualitatively categorized as absent, mild, moderate, or severe and quantitatively measured using the semi-automatic application. Linear weighted kappa values were calculated to assess the interobserver agreement of the stenosis and calcium categorization. The average and the standard deviation of the quantitative calcium volume were calculated for the calcium categories. For the stenosis measurements, the CTA images of 162 arteries yielded an interobserver correlation of 0.78 (P < 0.001). Kappa values of the categorized stenosis measurements were moderate: 0.45 and 0.58 for cutoff values of 30% and 50%, respectively. The kappa value for the calcium categorization was 0.62, with a good agreement between the qualitative and quantitative calcium assessment. Quantitative degree of stenosis measurement of the intracranial ICA on CTA is feasible with a good interobserver agreement ICA. Qualitative calcium categorization agrees well with quantitative measurements. (orig.)

  3. Automatic Frequency Controller for Power Amplifiers Used in Bio-Implanted Applications: Issues and Challenges

    Directory of Open Access Journals (Sweden)

    Mahammad A. Hannan

    2014-12-01

    Full Text Available With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil’s mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning

  4. Automatic Frequency Controller for Power Amplifiers Used in Bio-Implanted Applications: Issues and Challenges

    Science.gov (United States)

    Hannan, Mahammad A.; Hussein, Hussein A.; Mutashar, Saad; Samad, Salina A.; Hussain, Aini

    2014-01-01

    With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of

  5. Automatic devices for electrochemical water treatment with cooling of electrolyte

    Directory of Open Access Journals (Sweden)

    Trišović Tomislav Lj.

    2016-01-01

    Full Text Available The most common disinfectants for water treatment are based on chlorine and its compounds. Practically, water treatments with chlorine compounds have no alternative, since they provide, in comparison to other effective processes such as ozonization or ultraviolet irradiation, high residual disinfection capacity. Unfortunately, all of chlorine-based compounds for disinfection tend to degrade during storage, thus reducing the concentration of active chlorine. Apart from degradation, additional problems are transportation, storage and handling of such hazardous compounds. Nowadays, a lot of attention is paid to the development of electrochemical devices for in situ production of chlorine dioxide or sodium hypochlorite as efficient disinfectants for water treatment. The most important part of such a device is the electrochemical reactor. Electrochemical reactor uses external source of direct current in order to produce disinfectants in electrochemical reactions occurring at the electrodes. Construction of an electrochemical device for water treatment is based on evaluation of optimal conditions for electrochemical reactions during continues production of disinfectants. The aim of this study was to develop a low-cost electrochemical device for the production of disinfectant, active chlorine, at the place of its usage, based on newly developed technical solutions and newest commercial components. The projected electrochemical device was constructed and mounted, and its operation was investigated. Investigations involved both functionality of individual components and device in general. The major goal of these investigations was to achieve maximal efficiency in extreme condition of elevated room temperature and humidity with a novel device construction involving coaxial heat exchanger at the solution inlet. Room operation of the proposed device was investigated when relative humidity was set to 90% and the ambient temperature of 38°C. The obtained

  6. Automatic gamma spectrometry analytical apparatus

    International Nuclear Information System (INIS)

    Lamargot, J.-P.; Wanin, Maurice.

    1980-01-01

    This invention falls within the area of quantitative or semi-quantitative analysis by gamma spectrometry and particularly refers to a device for bringing the samples into the counting position. The purpose of this invention is precisely to provide an automatic apparatus specifically adapted to the analysis of hard gamma radiations. To this effect, the invention relates to a gamma spectrometry analytical device comprising a lead containment, a detector of which the sensitive part is located inside the containment and additionally comprising a transfer system for bringing the analyzed samples in succession to a counting position inside the containment above the detector. A feed compartment enables the samples to be brought in turn one by one on to the transfer system through a duct connecting the compartment to the transfer system. Sequential systems for the coordinated forward feed of the samples in the compartment and the transfer system complete this device [fr

  7. A handheld optical device for skin profile measurement

    Science.gov (United States)

    Sun, Jiuai; Liu, Xiaojin

    2018-04-01

    This paper describes a portable optical scanning device designed for skin surface measurement on both colour and 3D geometry through a relative easy and cost effective multiple light source photometric stereo method. The validation of colour recovered had been verified through its application on skin lesion segmentation in our early work. This paper focuses on the reconstructed topographic data which are subject to further evaluation and advancement. The evaluation work takes the skin in vitro as an application scenario and compares the experimental result to that obtained by using a commercial product. The experiments show that this handheld device can measure the skin profile significantly closer to that of the ground truth and have the additional function of skin colour recovery.

  8. Evaluation of impedance on biological Tissues using automatic control measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo [Pusan National University, Yangsan (Korea, Republic of); Lee, Moo Seok; Kim, Sang Sik [Pusan National University, Busan (Korea, Republic of); Kim, Gun FDo; Lee, Jong Kyu [Pukyung National University, Busan (Korea, Republic of)

    2015-08-15

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  9. Evaluation of impedance on biological Tissues using automatic control measurement system

    International Nuclear Information System (INIS)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo; Lee, Moo Seok; Kim, Sang Sik; Kim, Gun FDo; Lee, Jong Kyu

    2015-01-01

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  10. Automatic fuel charging machine for nuclear power plants

    International Nuclear Information System (INIS)

    Neda, Toshikazu; Aoki, Shigeo.

    1978-01-01

    Purpose: To enable smooth, safety and rapid refueling by automatically conducting a series of fuel exchange steps through the combination of calculations for fuel control and refueling works. Constitution: Processing operations are conducted based on various data from the memory unit of a computer that processes and stores various data inputted from a nuclear power plant, calculation systems stored in the memory unit of another computer, peripheral units such as typewriters and process input units. A refueling platform is operated by way of a platform control device and a platform driving device, and fuel exchange is conducted by the operation of a channel mounting and demounting device. (Yoshino, Y.)

  11. Measuring devices for the modular switch system; Messgeraete fuer den Schaltschrank

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Rudolf [Janitza Electronics GmbH, Lahnau (Germany). Sales und Marketing

    2008-10-15

    The advantages of digital universal measuring instruments are: lower device cost for more information and functionality. Furtheron digital measuring technology is more exactly during service life. Cost advantages result due to low installation cost and reduced installation of wires and cables. So universal devices replace all analogue systems and offer further functions. (orig./GL)

  12. Design and implementation of microcontroller-based automatic sequence counting and switching system

    Directory of Open Access Journals (Sweden)

    Joshua ABOLARINWA

    2015-05-01

    Full Text Available Technological advancement and its influence on human being have been on the increase in recent time. Major areas of such influence, include monitoring and control activities. In order to keep track of human movement in and out of a particular building, there is the need for an automatic counting system. Therefore, in this paper, we present the design and implementation of a microcontroller-based automatic sequence counting and switching system. This system was designed and developed to save cost, time, energy, and to achieve seamless control in the event of switching on or off of electrical appliances within a building. Top-down modular design approach was used in conjunction with the versatility of microcontroller. The system is able to monitor, sequentially count the number of entry and exit of people through an entrance, afterwards, automatically control any electrical device connected to it. From various tests and measurements obtained, there are comparative benefits derived from the deployment of this system in terms of simplicity and accuracy over similar system that is not microcontroller-based. Therefore, this system can be deployed at commercial quantity with wide range of applications in homes, offices and other public places.

  13. Automatic NAA. Saturation activities

    International Nuclear Information System (INIS)

    Westphal, G.P.; Grass, F.; Kuhnert, M.

    2008-01-01

    A system for Automatic NAA is based on a list of specific saturation activities determined for one irradiation position at a given neutron flux and a single detector geometry. Originally compiled from measurements of standard reference materials, the list may be extended also by the calculation of saturation activities from k 0 and Q 0 factors, and f and α values of the irradiation position. A systematic improvement of the SRM approach is currently being performed by pseudo-cyclic activation analysis, to reduce counting errors. From these measurements, the list of saturation activities is recalculated in an automatic procedure. (author)

  14. Motor automaticity in Parkinson’s disease

    Science.gov (United States)

    Wu, Tao; Hallett, Mark; Chan, Piu

    2017-01-01

    Bradykinesia is the most important feature contributing to motor difficulties in Parkinson’s disease (PD). However, the pathophysiology underlying bradykinesia is not fully understood. One important aspect is that PD patients have difficulty in performing learned motor skills automatically, but this problem has been generally overlooked. Here we review motor automaticity associated motor deficits in PD, such as reduced arm swing, decreased stride length, freezing of gait, micrographia and reduced facial expression. Recent neuroimaging studies have revealed some neural mechanisms underlying impaired motor automaticity in PD, including less efficient neural coding of movement, failure to shift automated motor skills to the sensorimotor striatum, instability of the automatic mode within the striatum, and use of attentional control and/or compensatory efforts to execute movements usually performed automatically in healthy people. PD patients lose previously acquired automatic skills due to their impaired sensorimotor striatum, and have difficulty in acquiring new automatic skills or restoring lost motor skills. More investigations on the pathophysiology of motor automaticity, the effect of L-dopa or surgical treatments on automaticity, and the potential role of using measures of automaticity in early diagnosis of PD would be valuable. PMID:26102020

  15. What Automaticity Deficit? Activation of Lexical Information by Readers with Dyslexia in a Rapid Automatized Naming Stroop-Switch Task

    Science.gov (United States)

    Jones, Manon W.; Snowling, Margaret J.; Moll, Kristina

    2016-01-01

    Reading fluency is often predicted by rapid automatized naming (RAN) speed, which as the name implies, measures the automaticity with which familiar stimuli (e.g., letters) can be retrieved and named. Readers with dyslexia are considered to have less "automatized" access to lexical information, reflected in longer RAN times compared with…

  16. Single-Image Distance Measurement by a Smart Mobile Device.

    Science.gov (United States)

    Chen, Shangwen; Fang, Xianyong; Shen, Jianbing; Wang, Linbo; Shao, Ling

    2017-12-01

    Existing distance measurement methods either require multiple images and special photographing poses or only measure the height with a special view configuration. We propose a novel image-based method that can measure various types of distance from single image captured by a smart mobile device. The embedded accelerometer is used to determine the view orientation of the device. Consequently, pixels can be back-projected to the ground, thanks to the efficient calibration method using two known distances. Then the distance in pixel is transformed to a real distance in centimeter with a linear model parameterized by the magnification ratio. Various types of distance specified in the image can be computed accordingly. Experimental results demonstrate the effectiveness of the proposed method.

  17. Automatic dirt trail analysis in dermoscopy images.

    Science.gov (United States)

    Cheng, Beibei; Joe Stanley, R; Stoecker, William V; Osterwise, Christopher T P; Stricklin, Sherea M; Hinton, Kristen A; Moss, Randy H; Oliviero, Margaret; Rabinovitz, Harold S

    2013-02-01

    Basal cell carcinoma (BCC) is the most common cancer in the US. Dermatoscopes are devices used by physicians to facilitate the early detection of these cancers based on the identification of skin lesion structures often specific to BCCs. One new lesion structure, referred to as dirt trails, has the appearance of dark gray, brown or black dots and clods of varying sizes distributed in elongated clusters with indistinct borders, often appearing as curvilinear trails. In this research, we explore a dirt trail detection and analysis algorithm for extracting, measuring, and characterizing dirt trails based on size, distribution, and color in dermoscopic skin lesion images. These dirt trails are then used to automatically discriminate BCC from benign skin lesions. For an experimental data set of 35 BCC images with dirt trails and 79 benign lesion images, a neural network-based classifier achieved a 0.902 are under a receiver operating characteristic curve using a leave-one-out approach. Results obtained from this study show that automatic detection of dirt trails in dermoscopic images of BCC is feasible. This is important because of the large number of these skin cancers seen every year and the challenge of discovering these earlier with instrumentation. © 2011 John Wiley & Sons A/S.

  18. Study on Automatic Solar Heat Insulated and Cooling Device of Car

    Directory of Open Access Journals (Sweden)

    Chen Gui-Yue

    2017-01-01

    Full Text Available In view of the common device for heat insulated and cooling of car, an improved new scheme which drove by solar energy is put forward. In this study, the transmission device are arranged inside the automobile, the thin-film solar is composited into the heat insulated and cooling material. Thus, the whole device can be driven by the energy from the photovoltaic conversion, which is clear and zero-pollution. The theoretical energy consumptions and preventable gas emissions are calculated to verify the environmental savings of the device. The results show that it has promising application prospect since it is not only environmentally friendly but also save and convenient as compared to the conventional device.

  19. 40 CFR 1065.275 - N2O measurement devices.

    Science.gov (United States)

    2010-07-01

    ... measurement devices. (a) General component requirements. We recommend that you use an analyzer that meets the... functions of other gaseous measurements and the engine's known or assumed fuel properties. The target value... gaseous measurements. The target value for any compensation algorithm is 0.0% (that is, no bias high and...

  20. Automatically sweeping dual-channel boxcar integrator

    International Nuclear Information System (INIS)

    Keefe, D.J.; Patterson, D.R.

    1978-01-01

    An automatically sweeping dual-channel boxcar integrator has been developed to automate the search for a signal that repeatedly follows a trigger pulse by a constant or slowly varying time delay when that signal is completely hidden in random electrical noise and dc-offset drifts. The automatically sweeping dual-channel boxcar integrator improves the signal-to-noise ratio and eliminates dc-drift errors in the same way that a conventional dual-channel boxcar integrator does, but, in addition, automatically locates the hidden signal. When the signal is found, its time delay is displayed with 100-ns resolution, and its peak value is automatically measured and displayed. This relieves the operator of the tedious, time-consuming, and error-prone search for the signal whenever the time delay changes. The automatically sweeping boxcar integrator can also be used as a conventional dual-channel boxcar integrator. In either mode, it can repeatedly integrate a signal up to 990 times and thus make accurate measurements of the signal pulse height in the presence of random noise, dc offsets, and unsynchronized interfering signals

  1. The making of pressure measurement device on heating-02 based realtime

    International Nuclear Information System (INIS)

    Giarno; Kussigit Santosa; Agus Nur Rachman; G B Heru K

    2013-01-01

    In order to modify the installation strand BETA Test Section Test integrated with heating-02 into a closed loop, it would require an additional system that can measure pressure changes in the closed-loop system. By making the measurement device to test the system pressure at the heating-expected 02 researchers can monitor the pressure changes that occur in the system. The pressure gauge device fabrication using manufacturing simulation methodology, the preparation of the hardware and software and test functions. Manufacturing simulation using measuring devices HIOKI DC current source Signal Source, preparation of pressure measurement devices require hardware such as pressure transducers, NI cRIO-9074, NI 9203 analog module, Computer and software LabVIEW 2011 as programming. In the test process function method is used to provide flow simulation module that is connected to the 9203 NI NI cRIO-9074. Current provision tailored to the specifics pressure transducer is 4 mA s/d 20 mA. Based on the test results obtained function value of the lowest current is 4.00 mA = 0.001 bar, and the highest current value of 20.00 mA = 4995 bar. From the results of calculations using the linear equations obtained correlation coefficient (R 2 ) of 0.999, so it is evident that the pressure changes in LabVIEW is affected by changes in flow. The results obtained from this activity is a device that can measure the pressure in the heating-02 test. (author)

  2. Word Processing in Dyslexics: An Automatic Decoding Deficit?

    Science.gov (United States)

    Yap, Regina; Van Der Leu, Aryan

    1993-01-01

    Compares dyslexic children with normal readers on measures of phonological decoding and automatic word processing. Finds that dyslexics have a deficit in automatic phonological decoding skills. Discusses results within the framework of the phonological deficit and the automatization deficit hypotheses. (RS)

  3. Measuring the accuracy of automatic shoeprint recognition methods.

    Science.gov (United States)

    Luostarinen, Tapio; Lehmussola, Antti

    2014-11-01

    Shoeprints are an important source of information for criminal investigation. Therefore, an increasing number of automatic shoeprint recognition methods have been proposed for detecting the corresponding shoe models. However, comprehensive comparisons among the methods have not previously been made. In this study, an extensive set of methods proposed in the literature was implemented, and their performance was studied in varying conditions. Three datasets of different quality shoeprints were used, and the methods were evaluated also with partial and rotated prints. The results show clear differences between the algorithms: while the best performing method, based on local image descriptors and RANSAC, provides rather good results with most of the experiments, some methods are almost completely unrobust against any unidealities in the images. Finally, the results demonstrate that there is still a need for extensive research to improve the accuracy of automatic recognition of crime scene prints. © 2014 American Academy of Forensic Sciences.

  4. Automatic programmable air ozonizer

    International Nuclear Information System (INIS)

    Gubarev, S.P.; Klosovsky, A.V.; Opaleva, G.P.; Taran, V.S.; Zolototrubova, M.I.

    2015-01-01

    In this paper we describe a compact, economical, easy to manage auto air ozonator developed at the Institute of Plasma Physics of the NSC KIPT. It is designed for sanitation, disinfection of premises and cleaning the air from foreign odors. A distinctive feature of the developed device is the generation of a given concentration of ozone, approximately 0.7 maximum allowable concentration (MAC), and automatic maintenance of a specified level. This allows people to be inside the processed premises during operation. The microprocessor controller to control the operation of the ozonator was developed

  5. Radiation dose measurements of the insertion devices using radiachromic film dosimeters

    International Nuclear Information System (INIS)

    Alderman, J.; Semones, E.; Job, P. K.

    2004-01-01

    The Advanced Photon Source (APS) uses Nd-Fe-B permanent magnets in the insertion devices to produce x-rays for scientific research [1,2]. Earlier investigations have exhibited varying degrees of demagnetization of these magnets [3] due to irradiation from electron beams [4,5,6], 60 Co γ-rays [5], and high-energy neutrons [7,8]. Radiation-induced demagnetization has been observed in the APS insertion devices [9] and was first measured in December of 2001. Partial demagnetization has also been observed in insertion devices at the European Synchrotron Radiation Facility (ESRF) [4,6], where Nd-Fe-B permanent magnets are also used. Growing concern for the lifetime of APS insertion devices, as well as the permanent magnets that will be used in next-generation, high-power light sources, like the FEL [10,11], resulted from the partial demagnetization observations made at both facilities. This concern in relation to radiation-induced demagnetization spurred a long-term project to measure and analyze the absorbed doses received by the APS insertion devices. The project required a reliable photon high-dose dosimetry technique capable of measuring absorbed doses greater than 10 6 rad, which was not readily available at the APS. Through a collaboration with the National Institute of Standards and Technology (NIST), one such technique using radiachromic films was considered, tested, and calibrated at the APS. This consequently led to the implementation of radiachromic film dosimetry for measuring the absorbed doses received by the insertion devices for each of the APS runs

  6. Opto-mechanical design of small infrared cloud measuring device

    Science.gov (United States)

    Zhang, Jiao; Yu, Xun; Tao, Yu; Jiang, Xu

    2018-01-01

    In order to make small infrared cloud measuring device can be well in a wide temperature range and day-night environment, a design idea using catadioptric infrared panoramic imaging optical system and simple mechanical structure for realizing observation clode under all-weather conditions was proposed. Firstly, the optical system of cloud measuring device was designed. An easy-to-use numerical method was proposed to acquire the profile of a catadioptric mirror, which brought the property of equidistance projection and played the most important role in a catadioptric panoramic lens. Secondly, the mechanical structure was studied in detail. Overcoming the limitations of traditional primary mirror support structure, integrative design was used for refractor and mirror support structure. Lastly, temperature adaptability and modes of the mirror support structure were analyzed. Results show that the observation range of the cloud measuring device is wide and the structure is simple, the fundamental frequency of the structure is greater than 100 Hz, the surface precision of the system reflector reaches PV of λ/10 and RMS of λ/40under the load of temperature range - 40 60°C, it can meet the needs of existing meteorological observation.

  7. Reactor power control device

    International Nuclear Information System (INIS)

    Doi, Kazuyori.

    1981-01-01

    Purpose: To automatically control the BWR type reactor power by simple and short-time searching the load pattern nearest to the required pattern at a nuclear power plant side. Constitution: The reactor power is automatically regulated by periodical modifying of coefficients fitting to a reactor core model, according as a required load pattern. When a load requirement pattern is given, a simulator estimates the total power change and the axial power distribution change from a xenon density change output calculated by a xenon dynamic characteristic estimating device, and a load pattern capable of being realized is searched. The amount to be recirculated is controlled on the basis of the load patteren thus searched, and the operation of the BWR type reactor is automatically controlled at the side of the nuclear power plant. (Kamimura, M.)

  8. Measurement-device-independent quantum digital signatures

    Science.gov (United States)

    Puthoor, Ittoop Vergheese; Amiri, Ryan; Wallden, Petros; Curty, Marcos; Andersson, Erika

    2016-08-01

    Digital signatures play an important role in software distribution, modern communication, and financial transactions, where it is important to detect forgery and tampering. Signatures are a cryptographic technique for validating the authenticity and integrity of messages, software, or digital documents. The security of currently used classical schemes relies on computational assumptions. Quantum digital signatures (QDS), on the other hand, provide information-theoretic security based on the laws of quantum physics. Recent work on QDS Amiri et al., Phys. Rev. A 93, 032325 (2016);, 10.1103/PhysRevA.93.032325 Yin, Fu, and Zeng-Bing, Phys. Rev. A 93, 032316 (2016), 10.1103/PhysRevA.93.032316 shows that such schemes do not require trusted quantum channels and are unconditionally secure against general coherent attacks. However, in practical QDS, just as in quantum key distribution (QKD), the detectors can be subjected to side-channel attacks, which can make the actual implementations insecure. Motivated by the idea of measurement-device-independent quantum key distribution (MDI-QKD), we present a measurement-device-independent QDS (MDI-QDS) scheme, which is secure against all detector side-channel attacks. Based on the rapid development of practical MDI-QKD, our MDI-QDS protocol could also be experimentally implemented, since it requires a similar experimental setup.

  9. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...... on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...

  10. Device for measuring high temperature heat conductivity of solids and melts

    International Nuclear Information System (INIS)

    Magomedov, Ya.B.; Gadzhiev, G.G.

    1990-01-01

    A modification of a device for measuring heat conductivity by a compensation method when a thermocouple with gadolinium sulfide being used is suggested. Such a device has less error of measurement (8%), wider interval of working temperatures (300-1600K) and it permits to investigate the material in the wide range of heat conductivity values (0.5-30 W/(mxK)). The stainless steel 12Kh18N10T, lanthanum sulfide and melted quartz were used for the device calibration. The results obtained and the literature data on these materials agree well between each other

  11. 49 CFR 236.401 - Automatic block signal system and interlocking standards applicable to traffic control systems.

    Science.gov (United States)

    2010-10-01

    ... TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Traffic Control Systems Standards § 236.401 Automatic... 49 Transportation 4 2010-10-01 2010-10-01 false Automatic block signal system and interlocking standards applicable to traffic control systems. 236.401 Section 236.401 Transportation Other Regulations...

  12. Zero G Mass Measurement Device (ZGMMD), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Zero G Mass Measurement Device (ZGMMD) will provide the ability to quantify the mass of objects up to 2,000 grams, including live animal specimens in a zero G...

  13. Cybersecurity for Connected Diabetes Devices.

    Science.gov (United States)

    Klonoff, David C

    2015-04-16

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. © 2015 Diabetes Technology Society.

  14. Method and device for automatic supervision of plants

    International Nuclear Information System (INIS)

    Pekrul, P.J.; Thiele, A.W.

    1976-01-01

    Method and device for the supervision of plants with respect to anomalous events and especially for monitoring dynamic signals from components of plants which are in operation, e.g. nuclear power plants, and not readily accessible for an inspection. (orig./RW) [de

  15. Use of piezoelectric multicomponent force measuring devices in fluid mechanics

    Science.gov (United States)

    Richter, A.; Stefan, K.

    1979-01-01

    The characterisitics of piezoelectric multicomponent transducers are discussed, giving attention to the advantages of quartz over other materials. The main advantage of piezoelectric devices in aerodynamic studies is their ability to indicate rapid changes in the values of physical parameters. Problems in the accuracy of measurments by piezoelectric devices can be overcome by suitable design approaches. A practical example is given of how such can be utilized to measure rapid fluctuations of fluid forces exerted on a circular cylinder mounted in a water channel.

  16. Automatic Lamp and Fan Control Based on Microcontroller

    Science.gov (United States)

    Widyaningrum, V. T.; Pramudita, Y. D.

    2018-01-01

    In general, automation can be described as a process following pre-determined sequential steps with a little or without any human exertion. Automation is provided with the use of various sensors suitable to observe the production processes, actuators and different techniques and devices. In this research, the automation system developed is an automatic lamp and an automatic fan on the smart home. Both of these systems will be processed using an Arduino Mega 2560 microcontroller. A microcontroller is used to obtain values of physical conditions through sensors connected to it. In the automatic lamp system required sensors to detect the light of the LDR (Light Dependent Resistor) sensor. While the automatic fan system required sensors to detect the temperature of the DHT11 sensor. In tests that have been done lamps and fans can work properly. The lamp can turn on automatically when the light begins to darken, and the lamp can also turn off automatically when the light begins to bright again. In addition, it can concluded also that the readings of LDR sensors are placed outside the room is different from the readings of LDR sensors placed in the room. This is because the light intensity received by the existing LDR sensor in the room is blocked by the wall of the house or by other objects. Then for the fan, it can also turn on automatically when the temperature is greater than 25°C, and the fan speed can also be adjusted. The fan may also turn off automatically when the temperature is less than equal to 25°C.

  17. Validation of a laser-assisted wound measurement device in a wound healing model.

    Science.gov (United States)

    Constantine, Ryan S; Bills, Jessica D; Lavery, Lawrence A; Davis, Kathryn E

    2016-10-01

    In the treatment and monitoring of a diabetic or chronic wound, accurate and repeatable measurement of the wound provides indispensable data for the patient's medical record. This study aims to measure the accuracy of the laser-assisted wound measurement (LAWM) device against traditional methods in the measurement of area, depth and volume. We measured four 'healing' wounds in a Play-Doh(®) -based model over five subsequent states of wound healing progression in which the model was irregularly filled in to replicate the healing process. We evaluated the LAWM device against traditional methods including digital photograph assessment with National Institutes of Health ImageJ software, measurements of depth with a ruler and weight-to-volume assessment with dental paste. Statistical analyses included analysis of variance (ANOVA) and paired t-tests. We demonstrate that there are significantly different and nearly statistically significant differences between traditional ruler depth measurement and LAWM device measurement, but there are no statistically significant differences in area measurement. Volume measurements were found to be significantly different in two of the wounds. Rate of percentage change was analysed for volume and depth in the wound healing model, and the LAWM device was not significantly different than the traditional measurement technique. While occasionally inaccurate in its absolute measurement, the LAWM device is a useful tool in the clinician's arsenal as it reliably measures rate of percentage change in depth and volume and offers a potentially aseptic alternative to traditional measurement techniques. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  18. System for the automatic analysis of defects in X-ray imaging

    International Nuclear Information System (INIS)

    Favier, C.; Thomas, G.; Brebant, C.; Mogavero, R.

    1984-05-01

    A radiological device was developed to obtain direct digitized views. A set of algorithms has been developed and demonstrated for the automatic evaluation of weldings. Some results concerning electronuclear fuel pin weldings are presented [fr

  19. GA/particle swarm intelligence based optimization of two specific varieties of controller devices applied to two-area multi-units automatic generation control

    Energy Technology Data Exchange (ETDEWEB)

    Bhatt, Praghnesh [Department of Electrical Engineering, Charotar Institute of Technology, Changa 388 421, Gujarat (India); Roy, Ranjit [Department of Electrical Engineering, S.V. National Institute of Technology, Surat 395 007, Gujarat (India); Ghoshal, S.P. [Department of Electrical Engineering, National Institute of Technology, Durgapur 713 209, West Bengal (India)

    2010-05-15

    This paper presents the comparative performance analysis of the two specific varieties of controller devices for optimal transient performance of automatic generation control (AGC) of an interconnected two-area power system, having multiple thermal-hydro-diesels mixed generating units. The significant improvement of optimal transient performance is observed with the addition of a thyristor-controlled phase shifter (TCPS) in the tie-line or capacitive energy storage (CES) units fitted in both the areas. Three different optimization algorithms are adopted for the sake of comparison of optimal performances and obtaining the optimal values of the gain settings of the devices independently. Craziness based particle swarm optimization (CRPSO) proves to be moderately fast algorithm and yields true optimal gains and minimum overshoot, minimum undershoot and minimum settling time of the transient response for any system. Comparative studies of TCPS and CES by any algorithm reveals that the CES units fitted in both the areas improve the transient performance to a greater extent following small load disturbance(s) in both the areas. (author)

  20. A full automatic system controlled with IBM-PC/XT micro-computer for neutron activation analysis

    International Nuclear Information System (INIS)

    Song Quanxun

    1992-01-01

    A full automatic system controlled with micro-computers for NAA is described. All processes are automatically completed with an IBM-PC/XT micro-computer. The device is stable, reliable, flexible and convenient for use and has many functions and applications in automatical analysis of long, middle and short lived nuclides. Due to a high working efficiency of the instrument and micro-computers, both time and power can be saved. This method can be applied in other nuclear analysis techniques

  1. Automatic Speech Recognition from Neural Signals: A Focused Review

    Directory of Open Access Journals (Sweden)

    Christian Herff

    2016-09-01

    Full Text Available Speech interfaces have become widely accepted and are nowadays integrated in various real-life applications and devices. They have become a part of our daily life. However, speech interfaces presume the ability to produce intelligible speech, which might be impossible due to either loud environments, bothering bystanders or incapabilities to produce speech (i.e.~patients suffering from locked-in syndrome. For these reasons it would be highly desirable to not speak but to simply envision oneself to say words or sentences. Interfaces based on imagined speech would enable fast and natural communication without the need for audible speech and would give a voice to otherwise mute people.This focused review analyzes the potential of different brain imaging techniques to recognize speech from neural signals by applying Automatic Speech Recognition technology. We argue that modalities based on metabolic processes, such as functional Near Infrared Spectroscopy and functional Magnetic Resonance Imaging, are less suited for Automatic Speech Recognition from neural signals due to low temporal resolution but are very useful for the investigation of the underlying neural mechanisms involved in speech processes. In contrast, electrophysiologic activity is fast enough to capture speech processes and is therefor better suited for ASR. Our experimental results indicate the potential of these signals for speech recognition from neural data with a focus on invasively measured brain activity (electrocorticography. As a first example of Automatic Speech Recognition techniques used from neural signals, we discuss the emph{Brain-to-text} system.

  2. Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Azcona, Juan Diego; Li, Ruijiang; Mok, Edward; Hancock, Steven; Xing, Lei

    2013-01-01

    Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators

  3. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT).

    Science.gov (United States)

    Topouchian, Jirar A; El Assaad, Mohamed A; Orobinskaia, Ludmila V; El Feghali, Ramzi N; Asmar, Roland G

    2006-06-01

    Two electronic devices for self-measurement of blood pressure - a brachial monitor, the Omron M6, and a wrist monitor, the Omron R7 - were evaluated in two separate studies according to the International Protocol of the European Society of Hypertension. The International Validation Protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood pressure measurements) making a total number of 33 participants (99 pairs of blood pressure measurements) on whom the final validation is performed. The same methodology recommended by the European Society of Hypertension protocol was applied for both studies. In each study and for each participant, four blood pressure measurements were taken simultaneously by two trained observers using mercury sphygmomanometers alternately with three measurements taken by the tested device. The difference between the blood pressure value given by the device and that obtained by the two observers (mean of the two observers) was calculated for each measure. The 99 pairs of blood pressure differences were classified into three categories (M6 device, and 0.2+/-4.2 and 0.2+/-2.9 mmHg for systolic and diastolic blood pressure, respectively, for the Omron R7 device. For both devices, readings differing by less than 5, 10 and 15 mmHg for systolic and diastolic blood pressure values fulfill the recommendation criteria of the International Protocol as well as the individual analysis. The Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT) devices fulfilled the validation recommendations of the International Protocol.

  4. System for connection of a scanning measuring equipment with a computer

    International Nuclear Information System (INIS)

    Avdeev, N.F.; Bogomolov, M.N.; Volkov, G.A.

    1976-01-01

    A system of communication of viewing and measuring devices is considered ensuring an on-line operation with BESM-4 computer. A program of film data processing is presented. A detailed description is given with respect to an interface. Modifications are mentioned in some units of the semi-automatic devices which ensure a communication with a computer. The communication system allows for a man-machine dialogue

  5. Universal Safety Distance Alert Device for Road Vehicles

    Directory of Open Access Journals (Sweden)

    Matic Virant

    2016-04-01

    Full Text Available Driving with too short of a safety distance is a common problem in road traffic, often with traffic accidents as a consequence. Research has identified a lack of vehicle-mountable devices for alerting the drivers of trailing vehicles about keeping a sufficient safe distance. The principal requirements for such a device were defined. A conceptual study was performed in order to select the components for the integration of the device. Based on the results of this study, a working prototype of a flexible, self-contained device was designed, built and tested. The device is intended to be mounted on the rear of a vehicle. It uses radar as the primary distance sensor, assisted with a GPS receiver for velocity measurement. A Raspberry Pi single-board computer is used for data acquisition and processing. The alerts are shown on an LED-matrix display mounted on the rear of the host vehicle. The device software is written in Python and provides automatic operation without requiring any user intervention. The tests have shown that the device is usable on almost any motor vehicle and performs reliably in simulated and real traffic. The open issues and possibilities for future improvements are presented in the Discussion.

  6. Development of a magnetic measurement device for thin ribbon samples

    International Nuclear Information System (INIS)

    Sato, Yuta; Todaka, Takashi; Enokizono, Masato

    2008-01-01

    This paper presents a magnetic measurement device for thin ribbon samples, which are produced by rapid cooling technique. This device enables us to measure magnetic properties easily by only inserting a ribbon sample into a sample holder. The sample holder was made by bakelite to fix any width sample. A long solenoid coil was used to generate a uniform magnetic field and the sample holder was placed at the mid part of the solenoid. The magnetic field strength was measured using a shunt resistor and the magnetic flux density and magnetization in sample ribbons were evaluated by using search coils. The accuracy of measurement was verified with an amorphous metal ribbon sample. Next, we have measured magnetic properties of some magnetic shape memory alloys, which have different compositions. The measured results are compared and we clarified the effect of Sm contents on the magnetic properties

  7. Improvement of a device for region radiation survey

    International Nuclear Information System (INIS)

    Poltinnikov, S.A.

    1978-01-01

    The electromechnanical device based on coding the turning angle of an automobile wheel by the number of electric pulses controlling the step motor of a film gate of gamma radiometer is proposed. The device is intended for automatizing recordings of gamma-radiation levels depending on a certain distance in a given terrain. The device has been tested at car speeds from 10 to 80 km/hr

  8. Door and window image-based measurement using a mobile device

    Science.gov (United States)

    Ma, Guangyao; Janakaraj, Manishankar; Agam, Gady

    2015-03-01

    We present a system for door and window image-based measurement using an Android mobile device. In this system a user takes an image of a door or window that needs to be measured and using interaction measures specific dimensions of the object. The existing object is removed from the image and a 3D model of a replacement is rendered onto the image. The visualization provides a 3D model with which the user can interact. When tested on a mobile Android platform with an 8MP camera we obtain an average measurement error of roughly 0.5%. This error rate is stable across a range of view angles, distances from the object, and image resolutions. The main advantages of our mobile device application for image measurement include measuring objects for which physical access is not readily available, documenting in a precise manner the locations in the scene where the measurements were taken, and visualizing a new object with custom selections inside the original view.

  9. Power control device

    International Nuclear Information System (INIS)

    Fukawa, Naohiro.

    1982-01-01

    Purpose: To alleviate the load of an operator by automatically operating the main controller, the speed controller, etc. of a recirculation control system and safely operating them without erroneous operation for long period of time, thereby improving the efficiency of a plant. Constitution: An electric type hydraulic control device controls loads of a turbine and a generator and outputs a control signal also to the main controller of a recirculation flow rate control system. At this time, the main controller is set at an automatic position, and the speed controller receives a recirculation pump speed signal from the main controller at the automatic position. The speed controller outputs a pump speed control signal to the recirculation pump system, and a reactor generates a power corresponding thereto. When the power control is automatically performed by the recirculation flow rate control, an operator sets a rate of change of the recirculation pump speed and the rate of change of the mean power range monitor at a change rate setting unit. Therefore, the control of the recirculation flow rate under the power control can be substantially entirely automated. (Yoshigara, H.)

  10. Methodology Investigation Automatic Magnetic Recording Borescope.

    Science.gov (United States)

    1986-01-01

    or other brushless signal coupling devices to the extent possible and feasible to reduce or eliminate the need for slip ring and brush type signal...the inspection head, is used to magnetically couple the necessary energy across the rotary interface. Because there is (1) an appreciable air gap in...were written. (2) As required by the contract, the signal conditioners in the MB employ automatic gain control to compensate for the changes in

  11. Automatic detection of measurement points for non-contact vibrometer-based diagnosis of cardiac arrhythmias

    Science.gov (United States)

    Metzler, Jürgen; Kroschel, Kristian; Willersinn, Dieter

    2017-03-01

    Monitoring of the heart rhythm is the cornerstone of the diagnosis of cardiac arrhythmias. It is done by means of electrocardiography which relies on electrodes attached to the skin of the patient. We present a new system approach based on the so-called vibrocardiogram that allows an automatic non-contact registration of the heart rhythm. Because of the contactless principle, the technique offers potential application advantages in medical fields like emergency medicine (burn patient) or premature baby care where adhesive electrodes are not easily applicable. A laser-based, mobile, contactless vibrometer for on-site diagnostics that works with the principle of laser Doppler vibrometry allows the acquisition of vital functions in form of a vibrocardiogram. Preliminary clinical studies at the Klinikum Karlsruhe have shown that the region around the carotid artery and the chest region are appropriate therefore. However, the challenge is to find a suitable measurement point in these parts of the body that differs from person to person due to e. g. physiological properties of the skin. Therefore, we propose a new Microsoft Kinect-based approach. When a suitable measurement area on the appropriate parts of the body are detected by processing the Kinect data, the vibrometer is automatically aligned on an initial location within this area. Then, vibrocardiograms on different locations within this area are successively acquired until a sufficient measuring quality is achieved. This optimal location is found by exploiting the autocorrelation function.

  12. A Simple Laser-Based Device for Simultaneous Microbial Culture and Absorbance Measurement

    OpenAIRE

    Abrevaya, X. C.; Cortón, E.; Areso, O.; Mauas, P. J. D.

    2012-01-01

    In this work we present a device specifically designed to study microbial growth with several applications related to environmental microbiology and other areas of research as astrobiology. The Automated Measuring and Cultivation device (AMC-d) enables semi-continuous absorbance measurements directly during cultivation. It can measure simultaneously up to 16 samples. Growth curves using low and fast growing microorganism were plotted, including Escherichia coli and Haloferax volcanii, a halop...

  13. A simple laser-based device for simultaneous microbial culture and absorbance measurement

    Science.gov (United States)

    Abrevaya, X. C.; Cortón, E.; Areso, O.; Mauas, P. J. D.

    2013-07-01

    In this work we present a device specifically designed to study microbial growth with several applications related to environmental microbiology and other areas of research as astrobiology. The Automated Measuring and Cultivation device (AMC-d) enables semi-continuous absorbance measurements directly during cultivation. It can measure simultaneously up to 16 samples. Growth curves using low and fast growing microorganism were plotted, including Escherichia coli and Haloferax volcanii, a halophilic archaeon.

  14. Measuring device for control rod driving time

    International Nuclear Information System (INIS)

    Tanaka, Kazuhiko; Hanabusa, Masatoshi.

    1993-01-01

    The present invention concerns a measuring device for control driving time having a function capable of measuring a selected control rod driving time and measuring an entire control rod driving time simultaneously. A calculation means and a store means for the selected rod control rod driving time, and a calculation means and a store means for the entire control rod driving time are disposed individually. Each of them measures the driving time and stores the data independent of each other based on a selected control rod insert ion signal and an entire control rod insertion signal. Even if insertion of selected and entire control rods overlaps, each of the control rod driving times can be measured reliably to provide an advantageous effect capable of more accurately conducting safety evaluation for the nuclear reactor based on the result of the measurement. (N.H.)

  15. Development of new techniques and enhancement of automatic capability of neutron activation analysis at the Dalat Research Reactor

    International Nuclear Information System (INIS)

    Ho Manh Dung; Ho Van Doanh; Tran Quang Thien; Pham Ngoc Tuan; Pham Ngoc Son; Tran Quoc Duong; Nguyen Van Cuong; Nguyen Minh Tuan; Nguyen Giang; Nguyen Thi Sy

    2017-01-01

    The techniques of neutron activation analysis (NAA) including cyclic, epithermal and prompt-gamma (CNAA, ENAA and PGNAA, respectively) have been developed at the Dalat research reactor (DRR). In addition, the efforts has been spent to improve the automatic capability of irradiation, measurement and data processing of NAA. The renewal of necessary devices/tools for sample preparation have also been done. Eventually, the performance and the utility in terms of sensitivity, accuracy and stability of the analytical results generated by NAA at DRR have significantly been improved. The main results of the project are: 1) Upgrading of the fast irradiation system on Channel 13-2/TC to allow the cyclic irradiations; 2) Development of CNAA; 3) Development of ENAA; 4) Application of k0-method for PGNAA; 5) Investigation of the automatic sample changer (ASC2); 6) Upgrading of Ko-DALAT software for ENAA and modification of k0-IAEA software for CNAA and PGNAA; and 7) Optimization of irradiation and measurement facilities as well as sample preparation devices/tools. A set of procedures of relevant developed techniques in the project were established. The procedures have been evaluated by analysis of the reference materials for which they are meeting the requirements of multi-element analysis for the intended applications. (author)

  16. Automatic TV X-ray unit for testing aluminium castings

    International Nuclear Information System (INIS)

    Morgunov, V.I.; Firstov, V.G.; Kisin, V.I.; Savostenok, M.I.

    1989-01-01

    The automatic TV X-ray unit for testing of aluminum alloy castings in a flow is described. The unit includes RAP-150/300 X-ray apparatus and PI-60TK TV X-ray device. The biological protection chamber and the common control board are the main functional units. The tests of the unit have shown that as regards its characteristics it is not worse than its foreign-made analogues, for example, devices of the DP-35 and DP-38 type of the 'Seifert' company

  17. Structure of the automatic system for plasma equilibrium position control

    International Nuclear Information System (INIS)

    Gubarev, V.F.; Krivonos, Yu.G.; Samojlenko, Yu.I.; Snegur, A.A.

    1978-01-01

    Considered are the principles of construction of the automatic system for plasma filament equilibrium position control inside the discharge chamber for the installation of a tokamak type. The combined current control system in control winding is suggested. The most powerful subsystem creates current in the control winding according to the program calculated beforehand. This system provides plasma rough equilibrium along the ''big radius''. The subsystem performing the current change in small limits according to the principle of feed-back coupling is provided simultaneously. The stabilization of plasma position is achieved in the discharge chamber. The advantage of construction of such system is in decreasing of the automatic requlator power without lowering the requirements to the accuracy of equilibrium preservation. The subsystem of automatic control of plasma position over the vertical is put into the system. Such an approach to the construction of the automatic control system proves to be correct; it is based on the experience of application of similar devices for some existing thermonuclear plants

  18. Compact and high-efficiency device for Raman scattering measurement using optical fibers.

    Science.gov (United States)

    Mitsui, Tadashi

    2014-11-01

    We describe the design and development of a high-efficiency optical measurement device for operation within the small bore of a high-power magnet at low temperature. For the high-efficiency measurement of light emitted from this small region, we designed a compact confocal optics with lens focusing and tilting systems, and used a piezodriven translation stage that allows micron-scale focus control of the sample position. We designed a measurement device that uses 10 m-long optical fibers in order to avoid the influence of mechanical vibration and magnetic field leakage of high-power magnets, and we also describe a technique for minimizing the fluorescence signal of optical fibers. The operation of the device was confirmed by Raman scattering measurements of monolayer graphene on quartz glass with a high signal-to-noise ratio.

  19. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation.

    Science.gov (United States)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-09-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C.Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland-Altman method was used to assess agreement between them.The devices showed agreement in overall tracking of changes in SO2. Test-retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range.Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative.

  20. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation

    International Nuclear Information System (INIS)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-01-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C. Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland–Altman method was used to assess agreement between them. The devices showed agreement in overall tracking of changes in SO2. Test–retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range. Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative. (paper)

  1. Simulation and measurement of short infrared pulses on silicon position sensitive device

    International Nuclear Information System (INIS)

    Krapohl, D; Esebamen, O X; Nilsson, H E; Thungstroem, G

    2011-01-01

    Lateral position sensitive devices (PSD) are important for triangulation, alignment and surface measurements as well as for angle measurements. Large PSDs show a delay on rising and falling edges when irradiated with near infra-red light. This delay is also dependent on the spot position relative to the electrodes. It is however desirable in most applications to have a fast response. We investigated the responsiveness of a Sitek PSD in a mixed mode simulation of a two dimensional full sized detector. For simulation and measurement purposes focused light pulses with a wavelength of 850 nm, duration of 1μs and spot size of 280μm were used. The cause for the slopes of rise and fall time is due to time constants of the device capacitance as well as the photo-generation mechanism itself. To support the simulated results, we conducted measurements of rise and fall times on a physical device. Additionally, we quantified the homogeneity of the device by repositioning a spot of light from a pulsed ir-laser diode on the surface area.

  2. Radiation detection and measurement concepts, methods and devices

    CERN Document Server

    McGregor, Douglas

    2019-01-01

    This text on radiation detection and measurement is a response to numerous requests expressed by students at various universities, in which the most popularly used books do not provide adequate background material, nor explain matters in understandable terms. This work provides a modern overview of radiation detection devices and radiation measurement methods. The topics selected in the book have been selected on the basis of the author’s many years of experience designing radiation detectors and teaching radiation detection and measurement in a classroom environment.

  3. Automatic centroid detection and surface measurement with a digital Shack–Hartmann wavefront sensor

    International Nuclear Information System (INIS)

    Yin, Xiaoming; Zhao, Liping; Li, Xiang; Fang, Zhongping

    2010-01-01

    With the breakthrough of manufacturing technologies, the measurement of surface profiles is becoming a big issue. A Shack–Hartmann wavefront sensor (SHWS) provides a promising technology for non-contact surface measurement with a number of advantages over interferometry. The SHWS splits the incident wavefront into many subsections and transfers the distorted wavefront detection into the centroid measurement. So the accuracy of the centroid measurement determines the accuracy of the SHWS. In this paper, we have presented a new centroid measurement algorithm based on an adaptive thresholding and dynamic windowing method by utilizing image-processing techniques. Based on this centroid detection method, we have developed a digital SHWS system which can automatically detect centroids of focal spots, reconstruct the wavefront and measure the 3D profile of the surface. The system has been tested with various simulated and real surfaces such as flat surfaces, spherical and aspherical surfaces as well as deformable surfaces. The experimental results demonstrate that the system has good accuracy, repeatability and immunity to optical misalignment. The system is also suitable for on-line applications of surface measurement

  4. Two devices for atmospheric electric field measurement

    International Nuclear Information System (INIS)

    Colombet, Andre; Hubert, Pierre.

    1977-02-01

    Two instruments installed at St Privat d'Allier for electric field measurement in connection with the rocket triggered lighting experiment program are described. The first one is a radioactive probe electrometer used as a warning device. The second is a field mill used for tape recording of electric field variation during the triggering events. Typical examples of such records are given [fr

  5. Comparative analysis of colour change measurement devices in textile industry

    Directory of Open Access Journals (Sweden)

    Paulina Gilewicz

    2014-08-01

    Full Text Available In the paper there is presented a trial of application of new measurement principle of colour change with the use of DigiEye device. Comparison of DigiEye with commonly use in the textile industry spectrophotometer Macbeth 2020 was an aim of determination of relationship between parameters of both measurement systems. Samples for the colour change assessment on both measurement systems were first aged in the Xenotest 150. Ageing process was done according to the method of blues scale. Results were obtained by the colour measurement devices before and after the ageing test each releasing the diaphragms during exposing the examined samples on the light. Result of colour change were obtained in the colour system CIE L*a*b*. The measurements were done for PES fabrics destined on the outer layers of clothing. [b]Keywords[/b]: textiles, spectrophotometer, colorimeter [b][/b

  6. Gain stabilization circuit of measuring devices with photomultipliers

    International Nuclear Information System (INIS)

    Seda, J.; Sabol, J.

    1974-01-01

    A circuit is designed for the stabilization of the gain of measuring devices with photomultipliers, suitable especially for the stabilization of scintillation detection systems, in which the correction signal is applied to the photomultiplier grid placed between the photocathode and the first dynode. (J.K.)

  7. Automatic food detection in egocentric images using artificial intelligence technology

    Science.gov (United States)

    Our objective was to develop an artificial intelligence (AI)-based algorithm which can automatically detect food items from images acquired by an egocentric wearable camera for dietary assessment. To study human diet and lifestyle, large sets of egocentric images were acquired using a wearable devic...

  8. Equipment for automatic measurement of gamma activity distribution in a column

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Vilcek, S.; Balkovsky, K.

    1978-01-01

    The design of a device for stepwise scanning of gamma activity distributions along chromatographic columns is described. In connection with a single-channel gamma spectrometer and a counting ratemeter with a recorder this device permits the resolution of a number of gamma emitters on the column, the determination of the gamma nuclide content in different chemical forms in the sample by means of column separation methods - Gel Chromatography Columns Scanning Method - and the determination of gamma nuclide distribution along the columns. The device permits the scanning of columns of up to 20 mm in diameter and 700 mm in length and continual scanning over a 450 mm column length with one clamping. With minor adaptations it is possible to scan columns up to 30 mm in diameter. The length of the scanned sections is 5 or 10 mm, the scanning time setting is arbitrary and variable activity levels and radiation energies may be measured. (author)

  9. PLC based automatic control of pasteurize mix in ice cream production

    Science.gov (United States)

    Yao, Xudong; Liang, Kai

    2013-03-01

    This paper describes the automatic control device of pasteurized mix in the ice cream production process.We design a scheme of control system using FBD program language and develop the programmer in the STEP 7-Micro/WIN software, check for any bugs before downloading into PLC .These developed devices will able to provide flexibility and accuracy to control the step of pasteurized mix. The operator just Input the duration and temperature of pasteurized mix through control panel. All the steps will finish automatically without any intervention in a preprogrammed sequence stored in programmable logic controller (PLC). With the help of this equipment we not only can control the quality of ice cream for various conditions, but also can simplify the production process. This control system is inexpensive and can be widely used in ice cream production industry.

  10. Photovoltaic Device Performance Evaluation Using an Open-Hardware System and Standard Calibrated Laboratory Instruments

    Directory of Open Access Journals (Sweden)

    Jesús Montes-Romero

    2017-11-01

    Full Text Available This article describes a complete characterization system for photovoltaic devices designed to acquire the current-voltage curve and to process the obtained data. The proposed system can be replicated for educational or research purposes without having wide knowledge about electronic engineering. Using standard calibrated instrumentation, commonly available in any laboratory, the accuracy of measurements is ensured. A capacitive load is used to bias the device due to its versatility and simplicity. The system includes a common part and an interchangeable part that must be designed depending on the electrical characteristics of each PV device. Control software, developed in LabVIEW, controls the equipment, performs automatic campaigns of measurements, and performs additional calculations in real time. These include different procedures to extrapolate the measurements to standard test conditions and methods to obtain the intrinsic parameters of the single diode model. A deep analysis of the uncertainty of measurement is also provided. Finally, the proposed system is validated by comparing the results obtained from some commercial photovoltaic modules to the measurements given by an independently accredited laboratory.

  11. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    OpenAIRE

    Mingrong Zhang; Songhao Wang; Yu-Ching Yang

    2016-01-01

    The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-de...

  12. A microprocessor based picture analysis system for automatic track measurements

    International Nuclear Information System (INIS)

    Heinrich, W.; Trakowski, W.; Beer, J.; Schucht, R.

    1982-01-01

    In the last few years picture analysis became a powerful technique for measurements of nuclear tracks in plastic detectors. For this purpose rather expensive commercial systems are available. Two inexpensive microprocessor based systems with different resolution were developed. The video pictures of particles seen through a microscope are digitized in real time and the picture analysis is done by software. The microscopes are equipped with stages driven by stepping motors, which are controlled by separate microprocessors. A PDP 11/03 supervises the operation of all microprocessors and stores the measured data on its mass storage devices. (author)

  13. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  14. Semi-automatic handling of meteorological ground measurements using WeatherProg: prospects and practical implications

    Science.gov (United States)

    Langella, Giuliano; Basile, Angelo; Bonfante, Antonello; De Mascellis, Roberto; Manna, Piero; Terribile, Fabio

    2016-04-01

    WeatherProg is a computer program for the semi-automatic handling of data measured at ground stations within a climatic network. The program performs a set of tasks ranging from gathering raw point-based sensors measurements to the production of digital climatic maps. Originally the program was developed as the baseline asynchronous engine for the weather records management within the SOILCONSWEB Project (LIFE08 ENV/IT/000408), in which daily and hourly data where used to run water balance in the soil-plant-atmosphere continuum or pest simulation models. WeatherProg can be configured to automatically perform the following main operations: 1) data retrieval; 2) data decoding and ingestion into a database (e.g. SQL based); 3) data checking to recognize missing and anomalous values (using a set of differently combined checks including logical, climatological, spatial, temporal and persistence checks); 4) infilling of data flagged as missing or anomalous (deterministic or statistical methods); 5) spatial interpolation based on alternative/comparative methods such as inverse distance weighting, iterative regression kriging, and a weighted least squares regression (based on physiography), using an approach similar to PRISM. 6) data ingestion into a geodatabase (e.g. PostgreSQL+PostGIS or rasdaman). There is an increasing demand for digital climatic maps both for research and development (there is a gap between the major of scientific modelling approaches that requires digital climate maps and the gauged measurements) and for practical applications (e.g. the need to improve the management of weather records which in turn raises the support provided to farmers). The demand is particularly burdensome considering the requirement to handle climatic data at the daily (e.g. in the soil hydrological modelling) or even at the hourly time step (e.g. risk modelling in phytopathology). The key advantage of WeatherProg is the ability to perform all the required operations and

  15. Measuring Visual Function Using the MultiQuity System: Comparison with an Established Device

    Directory of Open Access Journals (Sweden)

    Patrycja Smolarek-Kasprzak

    2014-01-01

    Full Text Available Purpose. To compare measures of visual acuity (VA and contrast sensitivity (CS from the Thompson Xpert 2000 and MultiQuity (MiQ devices. Methods. Corrected distance VA (CDVA and CS were measured in the right eye of 73 subjects, on an established system (Thompson Xpert and a novel system (MiQ 720. Regression was used to convert MiQ scores into the Thompson scale. Agreement between the converted MiQ and Thompson scores was investigated using standard agreement indices. Test-retest variability for both devices was also investigated, for a separate sample of 24 subjects. Results. For CDVA, agreement was strong between the MiQ and Thomson devices (accuracy = 0.993, precision = 0.889, CCC = 0.883. For CS, agreement was also strong (accuracy = 0.996, precision = 0.911, CCC = 0.907. Agreement was unaffected by demographic variables or by presence/absence of ocular pathology. Test-retest agreement indices for both devices were excellent: in the range 0.88–0.96 for CDVA and in the range 0.90–0.98 for CS. Conclusion. MiQ measurements exhibit strong agreement with corresponding Thomson measurements, and test-retest results are good for both devices. Agreement between the two devices is unaffected by age or ocular pathology.

  16. Development of an automatic prompt gamma-ray activation analysis system

    International Nuclear Information System (INIS)

    Osawa, Takahito

    2013-01-01

    An automatic prompt gamma-ray activation analysis system was developed and installed at the Japan Research Reactor No. 3 Modified (JRR-3M). The main control software, referred to as AutoPGA, was developed using LabVIEW 2011 and the hand-made program can control all functions of the analytical system. The core of the new system is an automatic sample exchanger and measurement system with several additional automatic control functions integrated into the system. Up to fourteen samples can be automatically measured by the system. (author)

  17. Automatic DGD and GVD compensation at 640 Gb/s based on scalar radio-frequency spectrum measurement

    DEFF Research Database (Denmark)

    Paquot, Yvan; Schröder, Jochen; Palushani, Evarist

    2013-01-01

    of separate GVD and DGD compensators using an impairment monitor based on an integrated all-optical radio-frequency (RF) spectrum analyzer. We show that low-bandwidth measurement of only a single tone in the RF spectrum is sufficient for automatic compensation for multiple degrees of freedom using...

  18. CT-automatic exposure control devices: What are their performances?

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Daniel [University Institute for Radiation Physics (IRA-DUMSC), Grand-Pre 1, CH-1007 Lausanne (Switzerland); Schmidt, Sabine; Denys, Alban; Schnyder, Pierre [Radiology Department, University Hospital of Lausanne, CHUV, CH-1011 Lausanne (Switzerland); Bochud, Francois O. [University Institute for Radiation Physics (IRA-DUMSC), Grand-Pre 1, CH-1007 Lausanne (Switzerland); Verdun, Francis R. [University Institute for Radiation Physics (IRA-DUMSC), Grand-Pre 1, CH-1007 Lausanne (Switzerland)], E-mail: francis.verdun@chuv.ch

    2007-10-01

    Purpose: To avoid unnecessary exposure to the patients, constructors have developed tube current modulation algorithms. The purpose of this work is to assess the performance of computed tomography (CT) tube current modulation concerning patient dose and image noise in MSCT scanners. Material and methods: A conical PMMA phantom with elliptical cross-section, to vary the thickness of the irradiated object in a monotonous way, and an anthropomorphic chest phantom were scanned under similar conditions on a general electrics (GE) LightSpeed VCT (64 slices) scanner. Noise measurements were made by calculating the standard deviation of the CT-number on a homogeneous ROI in both phantoms. The dose was estimated with the parameters read in the DICOM header of each studied image. Results: The study has shown that most of the time, constant noise levels (noise index) can be obtained by a variation of the mA. Nevertheless, this adaptation can be not fast enough when the variation of the attenuation changes is rapid. Thus, an adaptation length up to 5 cm was obtained. A 18% dose reduction can be achieved (mean of 9.9%) by switching from z-axis modulation algorithm to xyz-axis modulation option. However, exposure in the chest area can be higher with current modulation than without, when trying to keep an image noise level constant in thoraco-abdominal investigations. Conclusion: Current modulation algorithms can produce inadequate quality images due to problems with tube current stabilization when a sudden attenuation variation takes place as at the start of a scanning sequence. As expected, rotational (xyz-axis) modulation performs better than only z-axis modulation algorithm. The use of automatic exposure control (AEC) can lead to an increase of the dose if the maximum allowed current is not properly set in thoraco-abdominal acquisitions.

  19. Control device intended for a gamma radiation measuring instrument

    International Nuclear Information System (INIS)

    1976-01-01

    This invention concerns a monitoring device for a gamma radiation measuring instrument or radiation meter, in which the radiation to be measured brings about, inter alia, the ionisation of a gas and the generation of current pulses. The dial of this meter is generally calibrated in roentgens per hour, i.e. in radiation rate units. This instrument of very simple design is remarkable for its operating reliability. Preferably placed at the inlet to a radioactive area, it enables every user of a ratemeter to check, over the entire measuring range of this instrument, its proper operation prior to entering the area. To this effect, the monitoring device in question has a thick wall lead castle, having an internal cavity in which is mounted a radioactive source delivering a gamma radiation with given constant characteristics, through a measurement window closed by a calibrated plug. Lead doors articulated on the castle can be superimposed on this window to bring about a given attenuation of the radiation coming from the source and delivered to the exterior of the castle [fr

  20. Device for measuring the flow rate of a fluid moving through a pipe

    International Nuclear Information System (INIS)

    Barge, Gilles; Bouchard, Patrick; Chaix, J.E.; Rigaud, J.L.; Vivaldi, Andre.

    1981-01-01

    A device is described for measuring the flow rate, in particular through large section pipes, such as those found in water type nuclear reactors, thermal power stations and gas loops. This device includes a plate drilled with holes crossed by a fluid and held in the pipe by deformable components on which are secured strain gauges forming the detecting element of an electronic device for processing the signal emitted by the gauges. This device can be employed, for instance, for measuring the flow rate of a coolant in the primary system of a nuclear reactor [fr

  1. Development and evaluation of measurement devices used to support testing of radioactive material transportation packages

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Ammerman, D.J.; Stenberg, D.R.; Bronowski, D.R.; Arviso, M.

    1992-01-01

    Radioactive material package designers use structural testing to verify and demonstrate package performance. A major part of evaluating structural response is the collection of instrumentation measurement data. Sandia National Laboratories (SNL) has an ongoing program to develop and evaluate measurement devices to support testing of radioactive material packages. Measurement devices developed in support of this activity include evaluation channels, ruggedly constructed linear variable differential transformers, and piezoresistive accelerometers with enhanced measurement capabilities. In addition to developing measurement devices, a method has been derived to evaluate accelerometers and strain gages for measurement repeatability, ruggedness, and manufacturers' calibration data under both laboratory and field conditions. The developed measurement devices and evaluation technique will be discussed and the results of the evaluation will be presented

  2. Development of a chain limber and its measuring automatics; Karsimakoneen ja sen mittausautomatiikan kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Poeytaesaari, E [Eskon Paja, Kinnula (Finland)

    1997-12-01

    A new control system and measuring automatics are developed for a patented chain limber mountable to a farm tractor. The chain limber produces pulp wood and also limbed fuel logs. The project will be carried out in three stages: definition of the control system, development of the control system, and operational testing of the control system and the chain limber. The final stage of the project will be carried out in co-operation with the Work Efficiency Association. (orig.)

  3. The development of an enhanced strain measurement device to support testing of radioactive material packages

    International Nuclear Information System (INIS)

    Uncapkher, W.L.; Arviso, M.

    1995-01-01

    Radioactive material package designers use structural testing to verify and demonstrate package performance. A major part of evaluating structural response is the collection of reliable instrumentation measurement data. Over the last four decades, Sandia National Laboratories (SNL) has been actively involved in the development, testing, and evaluation of measurement devices for a broad range of applications, resulting in the commercialization of several measurement devices commonly used today. SNL maintains an ongoing program sponsored by the US Department of Energy (DOE) to develop and evaluate measurement devices to support testing of packages used to transport radioactive or hazardous materials. The development of the enhanced strain measurement device is part of this program

  4. Head-Impact–Measurement Devices: A Systematic Review

    Science.gov (United States)

    O'Connor, Kathryn L.; Rowson, Steven; Duma, Stefan M.; Broglio, Steven P.

    2017-01-01

    Context: With an estimated 3.8 million sport- and recreation-related concussions occurring annually, targeted prevention and diagnostic methods are needed. Biomechanical analysis of head impacts may provide quantitative information that can inform both prevention and diagnostic strategies. Objective: To assess available head-impact devices and their clinical utility. Data Sources: We performed a systematic search of the electronic database PubMed for peer-reviewed publications, using the following phrases: accelerometer and concussion, head impact telemetry, head impacts and concussion and sensor, head impacts and sensor, impact sensor and concussion, linear acceleration and concussion, rotational acceleration and concussion, and xpatch concussion. In addition to the literature review, a Google search for head impact monitor and concussion monitor yielded 15 more devices. Study Selection: Included studies were performed in vivo, used commercially available devices, and focused on sport-related concussion. Data Extraction: One author reviewed the title and abstract of each study for inclusion and exclusion criteria and then reviewed each full-text article to confirm inclusion criteria. Controversial articles were reviewed by all authors to reach consensus. Data Synthesis: In total, 61 peer-reviewed articles involving 4 head-impact devices were included. Participants in boxing, football, ice hockey, soccer, or snow sports ranged in age from 6 to 24 years; 18% (n = 11) of the studies included female athletes. The Head Impact Telemetry System was the most widely used device (n = 53). Fourteen additional commercially available devices were presented. Conclusions: Measurements collected by impact monitors provided real-time data to estimate player exposure but did not have the requisite sensitivity to concussion. Proper interpretation of previously reported head-impact kinematics across age, sport, and position may inform future research and enable staff clinicians

  5. Measurement campaign on connectivity of mesh networks formed by mobile devices

    DEFF Research Database (Denmark)

    Pietrarca, Beatrice; Sasso, Giovanni; Perrucci, Gian Paolo

    2007-01-01

    This paper reports the results of a measurement campaign on the connectivity level of mobile devices using Bluetooth (BT) to form cooperative mobile mesh networks. Such mobile mesh networks composed of mobile devices are the basis for any peer-to-peer communication like wireless grids or social...

  6. Radiation detector device for measuring ionizing radiation

    International Nuclear Information System (INIS)

    Brake, D. von der.

    1983-01-01

    The device contains a compensating filter circuit, which guarantees measurement of the radiation dose independent of the energy or independent of the energy and direction. The compensating filter circuit contains a carrier tube of a slightly absorbing metal with an order number not higher than 35, which surrounds a tubular detector and which carries several annular filter parts on its surface. (orig./HP) [de

  7. Tests, measurements, and characterization of electro-optic devices and systems

    International Nuclear Information System (INIS)

    Wadekar, S.G.

    1989-01-01

    This book contains the proceedings on tests, measurements and characterization of electro-optic devices and systems. Topics covered include: Measurement of spectral dynamics in single-quantum-well lasers, High power computer controlled laser diode characterization tester, and Laser diode characterization instrumentation

  8. Transmitting patient and device data via GSM--central management for decentral mobile medical devices.

    Science.gov (United States)

    Bachmor, T; Schöchlin, J; Bolz, A

    2002-01-01

    Equipping medical devices with long range telemetry opens completely new possibilities for emergency response, home care and remote diagnosis. Mobile communications nowadays seem to be a generally accepted part of our modern world, but bridging the gap between new (consumer-) technologies and medical devices still is a challenge today. Providing a telemetry link (GSM) is just the trivial part--ensuring security, reliability and service management are the more critical tasks that need to be addressed. Therefore, a complete system concept consists of an automatic fleet management (e.g. periodic device-initiated service calls) as well as customer relationship management (CRM), including technical service and a trouble-ticket system.

  9. A TECHNIQUE OF MEASURING OF RESISTANCE OF A GROUNDING DEVICE

    Directory of Open Access Journals (Sweden)

    I.V. Nizhevskyi

    2016-06-01

    Full Text Available Introduction. Measurement of resistance of the grounding device (GD by means of a three-electrode system. This requires not only the right choice of installation locations of measuring electrodes, but also the determination of the point of zero potential. Implementation of these requirements quite time-consuming, and in some cases impossible. Aim. Develop a new technique for measuring the electrical resistance of the GD. Task. The method of measuring the resistance of the GD with the help of a three-electrode setup is necessary to exclude the determination of the point of zero potential. Method. Mathematical modeling and calculation engine. Results. A three-electrode system for measuring the resistance of grounding devices (GD for various purposes is considered. On the basis of Maxwell equations a theoretical substantiation of a new technique for measuring the resistance of any GD of any construction in random soil structure has been proposed. An equation system of the sixth order has been obtained, its solution makes it possible to measure its own mutual resistance in the three-electrode installation with sufficiently high accuracy. Peculiarities of drawing up a calculation scheme of substitution of a three-electrode installation with lumped parameters: self and mutual impedance. Use of the principle of reciprocity eliminates the need of finding a point of zero potential which is a rather difficult task. The technique allows to minimize the spacing of measuring electrodes outside the GD, which substantially reduces the length of wiring of the measurement circuit and increases the «signal-to-interference» ratio and also removes the restrictions on the development of the territory outside the GD being tested. Conclusion. The procedure allows to evaluate the self and mutual impedance grounding all the electrodes in a three-electrode measuring installation of the grounding resistance of the device without finding the point of zero potential.

  10. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    Science.gov (United States)

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting

  11. PEPR and other CRT scanning and measuring devices

    Energy Technology Data Exchange (ETDEWEB)

    Pless, Irwin A. (Massachusetts Institute of Technology, Cambridge, MA 02139 (United States))

    1994-07-01

    This talk concentrates on the brief history of the PEPR (Precision Encoding and Pattern Recognition) scanning and measuring device.I restrict this reminiscence to just a short history of PEPR, the other various CRT scanners, a short summary of the capabilities of this scanner and some fond memories. ((orig.))

  12. PEPR and other CRT scanning and measuring devices

    International Nuclear Information System (INIS)

    Pless, Irwin A.

    1994-01-01

    This talk concentrates on the brief history of the PEPR (Precision Encoding and Pattern Recognition) scanning and measuring device.I restrict this reminiscence to just a short history of PEPR, the other various CRT scanners, a short summary of the capabilities of this scanner and some fond memories. ((orig.))

  13. Speech Recognition on Mobile Devices

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Lindberg, Børge

    2010-01-01

    in the mobile context covering motivations, challenges, fundamental techniques and applications. Three ASR architectures are introduced: embedded speech recognition, distributed speech recognition and network speech recognition. Their pros and cons and implementation issues are discussed. Applications within......The enthusiasm of deploying automatic speech recognition (ASR) on mobile devices is driven both by remarkable advances in ASR technology and by the demand for efficient user interfaces on such devices as mobile phones and personal digital assistants (PDAs). This chapter presents an overview of ASR...

  14. Development of computer-aided design system of elastic sensitive elements of automatic metering devices

    Science.gov (United States)

    Kalinkina, M. E.; Kozlov, A. S.; Labkovskaia, R. I.; Pirozhnikova, O. I.; Tkalich, V. L.; Shmakov, N. A.

    2018-05-01

    The object of research is the element base of devices of control and automation systems, including in its composition annular elastic sensitive elements, methods of their modeling, calculation algorithms and software complexes for automation of their design processes. The article is devoted to the development of the computer-aided design system of elastic sensitive elements used in weight- and force-measuring automation devices. Based on the mathematical modeling of deformation processes in a solid, as well as the results of static and dynamic analysis, the calculation of elastic elements is given using the capabilities of modern software systems based on numerical simulation. In the course of the simulation, the model was a divided hexagonal grid of finite elements with a maximum size not exceeding 2.5 mm. The results of modal and dynamic analysis are presented in this article.

  15. Realization of the ergonomics design and automatic control of the fundus cameras

    Science.gov (United States)

    Zeng, Chi-liang; Xiao, Ze-xin; Deng, Shi-chao; Yu, Xin-ye

    2012-12-01

    The principles of ergonomics design in fundus cameras should be extending the agreeableness by automatic control. Firstly, a 3D positional numerical control system is designed for positioning the eye pupils of the patients who are doing fundus examinations. This system consists of a electronically controlled chin bracket for moving up and down, a lateral movement of binocular with the detector and the automatic refocusing of the edges of the eye pupils. Secondly, an auto-focusing device for the object plane of patient's fundus is designed, which collects the patient's fundus images automatically whether their eyes is ametropic or not. Finally, a moving visual target is developed for expanding the fields of the fundus images.

  16. Evaluation of the Automatic Density Compensation for Pressurizer Level Measurement

    International Nuclear Information System (INIS)

    Jeong, Insoo; Min, Seohong; Ahn, Myunghoon

    2014-01-01

    When using two transmitters, it is difficult for the operators to identify the correct level of the pressurizer (PZR) upon failure of one of the two transmitters. For this reason, Korean Utility Requirements Document (KURD) requires that the operators to use three independent level indicators. Two hot calibrated transmitters and one cold calibrated transmitter compose PZR level transmitters in APR1400. In this paper, the deviation between cold calibration and hot calibration is evaluated, and the application of compensated PZR level measurement and uncompen-sated PZR level measurement during the normal operation of APR1400 are introduced. The PZR level signals for APR1400 come in three channels. To satisfy the KURD requirements for PZR level measurement, and at the same time to accomplish correction design and implementation, applicability and differences between hot calibration and cold calibration, compensated level and uncompensated level were evaluated as follows: For proper indication of PZR levels under normal operating condition, two of the three transmitters went through hot calibration and the remaining one transmitter went through cold calibration. This was to allow indicating entire regions of PZR regardless of the plant operation modes. For automatic density compensation per KURD requirements, the algorithm of the density compensated PZR level implemented in the DCS controller and PRV logic is adopted as a signal validation method

  17. Design and test of 4πβ-γ coincidence measurement device based on DSP technology

    International Nuclear Information System (INIS)

    Zeng Herong; Feng Qijie; Leng Jun; Qian Dazhi; Bai Lixin; Zhang Yiyun

    2012-01-01

    The paper illustrates the hardware and software of the 4πβ-γ coincidence measurement device based on DSP technology in detail. In such device, the single-channel analyzer, gate generator, coincidence circuit and scalar in the traditional coincidence measurement device are replaced by the digital coincidence acquirer which is researched and manufactured by ourselves. Doing so, the measurement efficiency will be respectively improved, and the hardware cost will be lowered. The comparison experiment shows that the design of such device is a success. (authors)

  18. Electronic trigger for capacitive touchscreen and extension of ISO 15781 standard time lag measurements to smartphones

    Science.gov (United States)

    Bucher, François-Xavier; Cao, Frédéric; Viard, Clément; Guichard, Frédéric

    2014-03-01

    We present in this paper a novel capacitive device that stimulates the touchscreen interface of a smartphone (or of any imaging device equipped with a capacitive touchscreen) and synchronizes triggering with the DxO LED Universal Timer to measure shooting time lag and shutter lag according to ISO 15781:2013. The device and protocol extend the time lag measurement beyond the standard by including negative shutter lag, a phenomenon that is more and more commonly found in smartphones. The device is computer-controlled, and this feature, combined with measurement algorithms, makes it possible to automatize a large series of captures so as to provide more refined statistical analyses when, for example, the shutter lag of "zero shutter lag" devices is limited by the frame time as our measurements confirm.

  19. Automatic determination of moisture content in biofuels based on NIR-measurements; Automatisk fukthaltsbestaemning av biobraenslen med NIR-metoden

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Magnus; Wiklund, Sven Erik [AaF-Process AB, Stockholm (Sweden); Karlsson, Mikael; Tryzell, Robert [Bestwood AB, Sundbyberg (Sweden)

    2005-07-01

    The determination of moisture content of biofuel is of large importance for the energy sector. The used methods for moisture determination are based on fuels samples taken from the bulk followed by drying and weighing. To be able to instead determine the moisture content based on a method with good accuracy and with a short response time would be a large improvement. Both for the fuel sampling and the following analysis there are Swedish standards but concerning the fuel sampling the standards are often not followed. The main reason is the difficulties to sample fuel samples from different depth from a delivery. This is one of the reasons that some plants have installed mechanical samplers but the investment cost for these is relatively high. The aim of this project was to investigate the use of the NIR-method for automatic moisture determination in biofuels. Within the project the NIR-method was used to determine the moisture content on withdrawn fuel samples, in addition the possibility to integrate the NIR-method in an automatic sampling system is also described. A large number of samples, in total over 200 samples, have been evaluated with the NIR-method and compared with the reference method, oven drying and gravimetric determination of moisture content. That the NIR-method can be used to determine moisture content in a number of well defined materials have previously been shown. In this report it has moreover been shown that the method can be used under the conditions at the fuel delivery station and for a large spectrum of biofuels. The accuracy that can be achieved with the NIR-method is in the same magnitude as the standard method, i.e. the reference method used for the measurements. Altogether this shows that the NIR-method is an interesting alternative for integration in an automatic measurement system for determination of fuel moisture content in biofuels. To be able to use the NIR-method for automatic determination of fuel moisture content at the

  20. A Flexible and Configurable Architecture for Automatic Control Remote Laboratories

    Science.gov (United States)

    Kalúz, Martin; García-Zubía, Javier; Fikar, Miroslav; Cirka, Luboš

    2015-01-01

    In this paper, we propose a novel approach in hardware and software architecture design for implementation of remote laboratories for automatic control. In our contribution, we show the solution with flexible connectivity at back-end, providing features of multipurpose usage with different types of experimental devices, and fully configurable…

  1. Development of advanced automatic control system for nuclear ship. 2. Perfect automatic operation after reactor scram events

    International Nuclear Information System (INIS)

    Yabuuchi, Noriaki; Nakazawa, Toshio; Takahashi, Hiroki; Shimazaki, Junya; Hoshi, Tsutao

    1997-11-01

    An automatic operation system has been developed for the purpose of realizing a perfect automatic plant operation after reactor scram events. The goal of the automatic operation after a reactor scram event is to bring the reactor hot stand-by condition automatically. The basic functions of this system are as follows; to monitor actions of the equipments of safety actions after a reactor scram, to control necessary control equipments to bring a reactor to a hot stand-by condition automatically, and to energize a decay heat removal system. The performance evaluation on this system was carried out by comparing the results using to Nuclear Ship Engineering Simulation System (NESSY) and the those measured in the scram test of the nuclear ship 'Mutsu'. As the result, it was showed that this system had the sufficient performance to bring a reactor to a hot syand-by condition quickly and safety. (author)

  2. Development of advanced automatic control system for nuclear ship. 2. Perfect automatic operation after reactor scram events

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Noriaki; Nakazawa, Toshio; Takahashi, Hiroki; Shimazaki, Junya; Hoshi, Tsutao [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-11-01

    An automatic operation system has been developed for the purpose of realizing a perfect automatic plant operation after reactor scram events. The goal of the automatic operation after a reactor scram event is to bring the reactor hot stand-by condition automatically. The basic functions of this system are as follows; to monitor actions of the equipments of safety actions after a reactor scram, to control necessary control equipments to bring a reactor to a hot stand-by condition automatically, and to energize a decay heat removal system. The performance evaluation on this system was carried out by comparing the results using to Nuclear Ship Engineering Simulation System (NESSY) and the those measured in the scram test of the nuclear ship `Mutsu`. As the result, it was showed that this system had the sufficient performance to bring a reactor to a hot syand-by condition quickly and safety. (author)

  3. Automatic Mode Transition Enabled Robust Triboelectric Nanogenerators.

    Science.gov (United States)

    Chen, Jun; Yang, Jin; Guo, Hengyu; Li, Zhaoling; Zheng, Li; Su, Yuanjie; Wen, Zhen; Fan, Xing; Wang, Zhong Lin

    2015-12-22

    Although the triboelectric nanogenerator (TENG) has been proven to be a renewable and effective route for ambient energy harvesting, its robustness remains a great challenge due to the requirement of surface friction for a decent output, especially for the in-plane sliding mode TENG. Here, we present a rationally designed TENG for achieving a high output performance without compromising the device robustness by, first, converting the in-plane sliding electrification into a contact separation working mode and, second, creating an automatic transition between a contact working state and a noncontact working state. The magnet-assisted automatic transition triboelectric nanogenerator (AT-TENG) was demonstrated to effectively harness various ambient rotational motions to generate electricity with greatly improved device robustness. At a wind speed of 6.5 m/s or a water flow rate of 5.5 L/min, the harvested energy was capable of lighting up 24 spot lights (0.6 W each) simultaneously and charging a capacitor to greater than 120 V in 60 s. Furthermore, due to the rational structural design and unique output characteristics, the AT-TENG was not only capable of harvesting energy from natural bicycling and car motion but also acting as a self-powered speedometer with ultrahigh accuracy. Given such features as structural simplicity, easy fabrication, low cost, wide applicability even in a harsh environment, and high output performance with superior device robustness, the AT-TENG renders an effective and practical approach for ambient mechanical energy harvesting as well as self-powered active sensing.

  4. Measuring Time in Sporting Competitions with the Domain-Specific Language EasyTime

    OpenAIRE

    Fister Jr., Iztok; Fister, Iztok

    2012-01-01

    Measuring time in mass sporting competitions is unthinkable manually today because of their long duration and unreliability. Besides, automatic timing devices based on the RFID technology have become cheaper. However, these devices cannot operate stand-alone. To work efficiently, they need a computer timing system for monitoring results. Such system should be capable of processing the incoming events, encoding and assigning results to a individual competitor, sorting results according to the ...

  5. Automatic feedback to promote safe walking and speech loudness control in persons with multiple disabilities: two single-case studies.

    Science.gov (United States)

    Lancioni, Giulio E; Singh, Nirbhay N; O'Reilly, Mark F; Green, Vanessa A; Alberti, Gloria; Boccasini, Adele; Smaldone, Angela; Oliva, Doretta; Bosco, Andrea

    2014-08-01

    Assessing automatic feedback technologies to promote safe travel and speech loudness control in two men with multiple disabilities, respectively. The men were involved in two single-case studies. In Study I, the technology involved a microprocessor, two photocells, and a verbal feedback device. The man received verbal alerting/feedback when the photocells spotted an obstacle in front of him. In Study II, the technology involved a sound-detecting unit connected to a throat and an airborne microphone, and to a vibration device. Vibration occurred when the man's speech loudness exceeded a preset level. The man included in Study I succeeded in using the automatic feedback in substitution of caregivers' alerting/feedback for safe travel. The man of Study II used the automatic feedback to successfully reduce his speech loudness. Automatic feedback can be highly effective in helping persons with multiple disabilities improve their travel and speech performance.

  6. An electrochemical sensor device for measuring blood ammonia at the point of care.

    Science.gov (United States)

    Brannelly, N T; Killard, A J

    2017-05-15

    The level of ammonia in blood is relevant in a number of medical conditions. While ammonia is a marker of dysfunction, elevated ammonia is itself a serious medical emergency and can lead to significant and permanent neurological impairment if not addressed quickly. Blood ammonia testing is typically performed in the central laboratory. While a number of point of care devices have been developed, these are based on classical enzymatic or colorimetric principles and have not been widely adopted. In this work, an electrochemical sensor device was developed for measuring blood ammonia. The device was based on the deposition of polyaniline nanoparticle films onto screen printed interdigitated electrodes using inkjet printing and their integration into a polymer microfabricated device with a polytetrafluoroethylene membrane. The device required a 52µL serum sample and measured the change in impedance of the sensor with respect to air at 1kHz, 5mV rms. The device was capable of the measurement of ammonia in serum across the physiologically relevant range of 25-200µM (r 2 =0.9984) and had a limit of detection of 12µM (n =3). The device showed no significant issues with common electrochemical interferences in blood. The device was also validated against a commercial spectrophotometric assay which resulted in excellent correlation (r =0.9699, pair (n =12) and could be stored in desiccant for at least five months. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Development of a method of testing irradiation devices by gamma scanning inside a research nuclear reactor

    International Nuclear Information System (INIS)

    Michel, Francois.

    1975-01-01

    A tridimensional experiment of spectrometry of an irradiation device located inside the reactor Siloe at a place shielded against spurious radiations, is exposed. The automatic scanning system that was developed, makes it possible to fully analyze in about 24 hours, the irradiation device (fuel pin, coolant and structures). The process combined with a 'pre-processing' program allows first partial results to be simultaneously obtained, more refined results being achieved during the next week, using the 'heavy processing'. The irradiation of the device is only interrupted during the compelling duty shutdown of the reactor, the evolution of the device during the successive irradiation cycles being thus followed up without pertubing said evolution. The reproducibility was studied at a local stage for testing the collimation of the detection unit (1% accuracy) and for testing the whole set 'processing measurement and computation' (5% accuracy). The sensitivity has been illustrated by detecting and measuring local singularities inside fuel (pellets), determining the detection efficiency dependence on the radial distribution of fission products and measuring nucleides inside the coolant flow (limiting value 10 -7 ). The accuracy of the method is evaluated at 5% for relative measurement of an experimental device during its in-pile lifetime and as 10% for quantitative absolute measurements [fr

  8. Electrical measuring device for a high temperature reactor

    International Nuclear Information System (INIS)

    Elter, C.; Handel, H.; Schoening, J.; Schmitt, H.

    1982-01-01

    The device for measuring the low or high neutron flux during start-up or at load is accommodated in an armoured guide tube projecting into the floor. A gas-tight capsule is formed as the measuring column with outer dome with a lid solidly connected by a flange to the armoured tube situated on the side wall of the concrete reactor vessel, together with the armoured guide tube. Two shielding shutters prevent the passage of radiation through the armoured tube. (DG) [de

  9. Light collection optics for measuring flux and spectrum from light-emitting devices

    Science.gov (United States)

    McCord, Mark A.; DiRegolo, Joseph A.; Gluszczak, Michael R.

    2016-05-24

    Systems and methods for accurately measuring the luminous flux and color (spectra) from light-emitting devices are disclosed. An integrating sphere may be utilized to directly receive a first portion of light emitted by a light-emitting device through an opening defined on the integrating sphere. A light collector may be utilized to collect a second portion of light emitted by the light-emitting device and direct the second portion of light into the integrating sphere through the opening defined on the integrating sphere. A spectrometer may be utilized to measure at least one property of the first portion and the second portion of light received by the integrating sphere.

  10. Automatic tuning of Bragg condition in a radio-acoustic system for PBL temperature profile measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bonino, G; Trivero, P

    1985-01-01

    A Radio-Acoustic Sounding System (RASS) with acoustic wavelength lambda/sub a/ approx. 1m was designed and successfully tested. The system proved to be capable of measuring the vertical temperature profile in the Planetary Boundary Layer (PBL) with an accuracy and vertical resolution comparable to that of traditional apparatus (radiothermosondes borne by tethered or disposable balloons, thermosondes borne by aircraft and so on), yet combined with the advantages typical of remote sensing techniques. Up to the summer of 1983 the system needed attendance by an operator who had to identify the acoustic sounding frequency affording the fundamental condition of Bragg resonance between acoustic and radio wavelengths. Features and performance of the new completely automatic RASS arrangement are presented. These include the possibility of obtaining average thermal vertical profiles at preset time intervals. Maximum range of the possibility of obtaining average thermal vertical profiles at preset time intervals. Maximum range of measurements obtained in about 1000 1/2-h averages was: in 90% of cases greater than or equal to 600 m; in 50% of cases greater than or equal to 1100m. Such results indicate the usefulness of automatic RASS as a tool for meteorological purposes and for the application of air pollution control strategies.

  11. Robust automatic control system of vessel descent-rise device for plant with distributed parameters “cable – towed underwater vehicle”

    Science.gov (United States)

    Chupina, K. V.; Kataev, E. V.; Khannanov, A. M.; Korshunov, V. N.; Sennikov, I. A.

    2018-05-01

    The paper is devoted to a problem of synthesis of the robust control system for a distributed parameters plant. The vessel descent-rise device has a heave compensation function for stabilization of the towed underwater vehicle on a set depth. A sea state code, parameters of the underwater vehicle and cable vary during underwater operations, the vessel heave is a stochastic process. It means that the plant and external disturbances have uncertainty. That is why it is necessary to use the robust theory for synthesis of an automatic control system, but without use of traditional methods of optimization, because this cable has distributed parameters. The offered technique has allowed one to design an effective control system for stabilization of immersion depth of the towed underwater vehicle for various degrees of sea roughness and to provide its robustness to deviations of parameters of the vehicle and cable’s length.

  12. Compressed optimization of device architectures

    Energy Technology Data Exchange (ETDEWEB)

    Frees, Adam [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Gamble, John King [Microsoft Research, Redmond, WA (United States). Quantum Architectures and Computation Group; Ward, Daniel Robert [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Center for Computing Research; Blume-Kohout, Robin J [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Center for Computing Research; Eriksson, M. A. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Friesen, Mark [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Coppersmith, Susan N. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics

    2014-09-01

    Recent advances in nanotechnology have enabled researchers to control individual quantum mechanical objects with unprecedented accuracy, opening the door for both quantum and extreme- scale conventional computation applications. As these devices become more complex, designing for facility of control becomes a daunting and computationally infeasible task. Here, motivated by ideas from compressed sensing, we introduce a protocol for the Compressed Optimization of Device Architectures (CODA). It leads naturally to a metric for benchmarking and optimizing device designs, as well as an automatic device control protocol that reduces the operational complexity required to achieve a particular output. Because this protocol is both experimentally and computationally efficient, it is readily extensible to large systems. For this paper, we demonstrate both the bench- marking and device control protocol components of CODA through examples of realistic simulations of electrostatic quantum dot devices, which are currently being developed experimentally for quantum computation.

  13. Hardware simulation of automatic braking system based on fuzzy logic control

    Directory of Open Access Journals (Sweden)

    Noor Cholis Basjaruddin

    2016-07-01

    Full Text Available In certain situations, a moving or stationary object can be a barrier for a vehicle. People and vehicles crossing could potentially get hit by a vehicle. Objects around roads as sidewalks, road separator, power poles, and railroad gates are also a potential source of danger when the driver is inattentive in driving the vehicle. A device that can help the driver to brake automatically is known as Automatic Braking System (ABS. ABS is a part of the Advanced Driver Assistance Systems (ADAS, which is a device designed to assist the driver in driving the process. This device was developed to reduce human error that is a major cause of traffic accidents. This paper presents the design of ABS based on fuzzy logic which is simulated in hardware by using a remote control car. The inputs of fuzzy logic are the speed and distance of the object in front of the vehicle, while the output of fuzzy logic is the intensity of braking. The test results on the three variations of speed: slow-speed, medium-speed, and high-speed shows that the design of ABS can work according to design.

  14. Design and Application of Automatic Falling Device for Different Brands of Goods

    Science.gov (United States)

    Yang, Xudong; Ge, Qingkuan; Zuo, Ping; Peng, Tao; Dong, Weifu

    2017-12-01

    The Goods-Falling device is an important device in the intelligent sorting goods sorting system, which is responsible for the temporary storage and counting of the goods, and the function of putting the goods on the conveyor belt according to certain precision requirements. According to the present situation analysis and actual demand of the domestic goods sorting equipment, a vertical type Goods - Falling Device is designed and the simulation model of the device is established. The dynamic characteristics such as the angular error of the opening and closing mechanism are carried out by ADAMS software. The simulation results show that the maximum angular error is 0.016rad. Through the test of the device, the goods falling speed is 7031/hour, the good of the falling position error within 2mm, meet the crawl accuracy requirements of the palletizing robot.

  15. Development of the system for excitation function automatic measurement of nuclear reactions

    International Nuclear Information System (INIS)

    Sapozhnikov, A.B.

    2004-01-01

    Full text: The resonance nuclear reaction method is applied at the tandem accelerator UKP-2-1 to determinate films thickness and obtain light element depth distribution. The system for automatic measurement of the nuclear reaction excitation curve has been developed. It allowed to obtain an excitation function of nuclear reaction using continuous changing potential of the target with energy step of 6 eV. Saw-tooth voltage with amplitude up to 6 kV from the block of scanning beam is fed to a target. The amplitude is determined by constant voltage from the scanning beam block control. Nal(Tl) detector detects gamma quanta - the products of a nuclear reaction and transforms they in voltage impulses. The impulses through the amplifier income in the single-channel analyzer which forms impulses to start the analog-to-digital converter. The value of saw-tooth voltage corresponding to the moment of gamma quantum detection is read by the analog-to-digital converter, where it is transformed to digital code and transmitted to the computer. The computer program has been developed to control the process of accumulation of excitation function. The dependence a detected γ-quanta yield from a target potential is automatically plotted by the program. This dependence corresponds to the nuclear reaction excitation function. If scanning amplitude is not enough in order to scan need depth of a sample, an operator increases energy of the proton beam changing high voltage potential of the terminal up 3 keV and measures the nuclear reaction excitation function with the new energy. This procedure can be repeated some times. After that 'sewing' of excitation functions is carried out by the program under the hypothesis that nuclear reaction yield in last points be identical

  16. A cryogenic current-measuring device with nano-ampere resolution at the storage ring TARN II

    International Nuclear Information System (INIS)

    Tanabe, T.; Chida, K.; Shinada, K.

    1999-01-01

    In cooler-ring experiments, an accurate and non-destructive current measurement is essential for determining the reaction cross sections. The lowest current which can be measured by the DC current transformer commonly used so far is some μA. In order to measure a low-beam current from nA to μA, we made a cryogenic current-measuring device using a superconducting quantum interference devices (SQUID), and measured the circulating ion current at the cooler ring TARN II. This paper gives the design and performance of the device

  17. Burnup degree measuring device for spent fuel

    International Nuclear Information System (INIS)

    Doi, Hideo; Imaizumi, Hideki; Endo, Yasumi; Itahara, Kuniyuki.

    1994-01-01

    The present invention provides a small-sized and convenient device for measuring a burnup degree of spent fuels, which can be installed without remodelling an existent fuel storage pool. Namely, a gamma-ray detecting portion incorporates a Cd-Te detector for measuring intensity ratio of gamma-rays. A neutron detecting portion incorporates a fission counter tube. The Cd-Te detector comprises a neutron shielding member for reducing radiation damages and a background controlling plate for reducing low energy gamma-rays entering from a collimator. Since the Cd-Td detector for use in a gamma-ray spectroscopy can be used at a normal temperature and can measure even a relatively strong radiation field, it can measure the intensity of gamma-rays from Cs-137 and Cs-134 in spent fuels accurately at a resolving power of less than 10 keV. Further, in a case where a cooling period is less than one year, gamma-rays from Rh-106 and Nb-95 can also be measured. (I.S.)

  18. A device for automated phase space measurement of ion beams

    International Nuclear Information System (INIS)

    Lukas, J.; Priller, A.; Steier, P.

    2007-01-01

    Equipment for automated phase-space measurements was developed at the VERA Lab. The measurement of the beam's intensity distribution, as well as its relative position with respect to the reference orbit is performed at two locations along the beam line. The device basically consists of moveable slits and a beam profile monitor, which are both coordinated and controlled by an embedded controller. The operating system of the controller is based on Linux with real-time extension. It controls the movement of the slits and records the data synchronized to the movement of the beam profile monitor. The data is sent via TCP/IP to the data acquisition system of VERA where visualization takes place. The duration of one phase space measurement is less than 10 s, which allows for using the device during routine beam tuning

  19. 21 CFR 886.1450 - Corneal radius measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Corneal radius measuring device. 886.1450 Section 886.1450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... corneal size by superimposing the image of the cornea on a scale at the focal length of the lens of a...

  20. Measuring automatic retrieval: a comparison of implicit memory, process dissociation, and speeded response procedures.

    Science.gov (United States)

    Horton, Keith D; Wilson, Daryl E; Vonk, Jennifer; Kirby, Sarah L; Nielsen, Tina

    2005-07-01

    Using the stem completion task, we compared estimates of automatic retrieval from an implicit memory task, the process dissociation procedure, and the speeded response procedure. Two standard manipulations were employed. In Experiment 1, a depth of processing effect was found on automatic retrieval using the speeded response procedure although this effect was substantially reduced in Experiment 2 when lexical processing was required of all words. In Experiment 3, the speeded response procedure showed an advantage of full versus divided attention at study on automatic retrieval. An implicit condition showed parallel effects in each study, suggesting that implicit stem completion may normally provide a good estimate of automatic retrieval. Also, we replicated earlier findings from the process dissociation procedure, but estimates of automatic retrieval from this procedure were consistently lower than those from the speeded response procedure, except when conscious retrieval was relatively low. We discuss several factors that may contribute to the conflicting outcomes, including the evidence for theoretical assumptions and criterial task differences between implicit and explicit tests.

  1. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol.

    Science.gov (United States)

    Altunkan, Sekip; Ilman, Nevzat; Altunkan, Erkan

    2007-04-01

    A variety of automatic blood measurement devices with diverse features have been introduced to the medical markets recently. Among these devices, models that measure at the wrist have become increasingly popular in self measurements. The objective of this study was to evaluate the accuracy of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure devices against the mercury sphygmomanometer in adults according to the International Protocol criteria. Fifty-four patients over 30 years of age were studied and classified based on the International Protocol range. Blood pressure measurements at the wrist with the Samsung SBM-100A and Microlife BP 3BU1-5 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential blood pressure measurements were taken. A total of 33 participants with randomly distributed arm circumferences were selected for both of the validation studies. During each validation study, 99 measurements were obtained for comparison from 33 participants. The first phase was performed on 15 participants and if the device passed this phase, 18 more participants were selected. Mean discrepancies and standard deviations of the device-sphygmomanometer were 0.9+/-9.2 and -2.7+/-9.3 mmHg for systolic blood pressure and -1.4+/-8.0 mmHg and 1.4+/-5.7 for diastolic blood pressure in the Samsung and Microlife study groups, respectively. The Samsung SBM-100A passed Phase 1 in 15 participants. Despite the fact that Microlife BP 3BU1-5 passed Phase 1 for diastolic pressure, it failed according to the systolic pressure criteria. Eighteen patients were added and Phase 2 was continued, in which Samsung SBM-100A failed to meet the criteria of Phases 2.1 and 2.2 for adults in systolic and diastolic blood pressure. It was found that the Microlife BP 3BU1-5 does not meet the criteria of either of Phases 2.1 and 2.2 for systolic blood pressure and Phase 2.2 for diastolic blood pressure. In this study, Samsung SBM

  2. DB-1900 low-background measuring device of alpha and beta

    International Nuclear Information System (INIS)

    Liu Hongquan; Gan Jinbang; Chen Qi; Zhao Yunqing

    1997-08-01

    The device is a box-type detector used to measure the emissivity of Alpha and Beta from dry samples under 2π geometry in radionuclide metrology. It is composed of a high efficiency αβ detector with electrostatic screen of zero potential [patent ZL92111938.0 (in China)] and anticoincidence detector in lead chamber, and has been reasonably combined with double anticoincidence technique to form integral equipment. The characteristics of the device are as follows: It can stably measure the emissivity of Alpha and Beta from dry samples with less surface conductivity (the surface resistance of the samples: 13 Ω) in detector. It can measure Beta emissivity from samples in which Alpha coexist with Beta, and discrimination between Alpha and Beta emissivities can be made simultaneously by two paths. It is a good quantitative means for measuring Alpha and Beta radiation in radiometry, radiation protection and environmental protection. It could be used to measure weak radiativity of Alpha and Beta samples from scientific research, minerals, building materials, plastics, medicinal materials, seas and oceans biology, et al. (7 refs., 8 tabs., 17 figs.)

  3. Transducer-actuator systems and methods for performing on-machine measurements and automatic part alignment

    Science.gov (United States)

    Barkman, William E.; Dow, Thomas A.; Garrard, Kenneth P.; Marston, Zachary

    2016-07-12

    Systems and methods for performing on-machine measurements and automatic part alignment, including: a measurement component operable for determining the position of a part on a machine; and an actuation component operable for adjusting the position of the part by contacting the part with a predetermined force responsive to the determined position of the part. The measurement component consists of a transducer. The actuation component consists of a linear actuator. Optionally, the measurement component and the actuation component consist of a single linear actuator operable for contacting the part with a first lighter force for determining the position of the part and with a second harder force for adjusting the position of the part. The actuation component is utilized in a substantially horizontal configuration and the effects of gravitational drop of the part are accounted for in the force applied and the timing of the contact.

  4. Using Smart Devices to Measure Intermittent Noise in the Workplace

    Directory of Open Access Journals (Sweden)

    Benjamin Roberts

    2017-01-01

    Full Text Available Purpose: To determine the accuracy of smart devices (iPods to measure intermittent noise and integrate a noise dose in the workplace. Materials and Methods: In experiment 1, four iPods were each paired with a Larson Davis Spark dosimeter and exposed to randomly fluctuating pink noise in a reverberant sound chamber. Descriptive statistics and the mean difference between the iPod and its paired dosimeter were calculated for the 1-s data logged measurements. The calculated time weighted average (TWA was also compared between the devices. In experiment 2, 15 maintenance workers and 14 office workers wore an iPod and dosimeter during their work-shift for a maximum of five workdays. A mixed effects linear regression model was used to control for repeated measures and to determine the effect of the device type on the projected 8-h TWA. Results: In experiment 1, a total of 315,306 1-s data logged measurements were made. The interquartile range of the mean difference fell within ±2.0 A-weighted decibels (dBA, which is the standard used by the American National Standards Institute to classify a type 2 sound level meter. The mean difference of the calculated TWA was within ±0.5 dBA except for one outlier. In experiment 2, the results of the mixed effects model found that, on average, iPods measured an 8-h TWA 1.7 dBA higher than their paired dosimeters. Conclusion: This study shows that iPods have the ability to make reasonably accurate noise measurements in the workplace, but they are not as accurate as traditional noise dosimeters.

  5. Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

    Science.gov (United States)

    Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao

    2002-04-01

    Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar

  6. Evaluation efficiency for mobile as discharge measurement device for partially filled circular channel

    Directory of Open Access Journals (Sweden)

    I.M.H. Rashwan

    2013-06-01

    Full Text Available Discharge measurement is an important step in engineering applications such as sewerage system, irrigation and drainage system. Mobile flume is a simple and low-cost discharge measuring device constructed of two pieces of pipes, one installed vertically inside the other. The circular mobile flume depends on the concept of developing a contracted zone to have a control section. To evaluate the efficiency of this type of device mathematical and experimental studies are presented. Specific energy, discharge and Froude number equations are used to develop mathematical model. Experimental work is carried out to measure the discharge values corresponding to the specific energy values. The experimental data is used to evaluate the mobile flume as a device to measure discharge. A new equation for the discharge coefficient is presented. This equation can be used to determined accurate discharge with knowing the contraction ratio and measured specific energy.

  7. Method and device for bio-impedance measurement with hard-tissue applications

    International Nuclear Information System (INIS)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-01-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kΩ to 10 MΩ across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kΩ to 10 MΩ and from 20 pF to 100 pF, are discussed

  8. Method and device for bio-impedance measurement with hard-tissue applications.

    Science.gov (United States)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-06-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kOmega to 10 MOmega across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kOmega to 10 MOmega and from 20 pF to 100 pF, are discussed.

  9. Automatic control of commercial computer programs

    International Nuclear Information System (INIS)

    Rezvov, B.A.; Artem'ev, A.N.; Maevskij, A.G.; Demkiv, A.A.; Kirillov, B.F.; Belyaev, A.D.; Artem'ev, N.A.

    2010-01-01

    The way of automatic control of commercial computer programs is presented. The developed connection of the EXAFS spectrometer automatic system (which is managed by PC for DOS) is taken with the commercial program for the CCD detector control (which is managed by PC for Windows). The described complex system is used for the automation of intermediate amplitude spectra processing in EXAFS spectrum measurements at Kurchatov SR source

  10. A novel automatic method for monitoring Tourette motor tics through a wearable device.

    Science.gov (United States)

    Bernabei, Michel; Preatoni, Ezio; Mendez, Martin; Piccini, Luca; Porta, Mauro; Andreoni, Giuseppe

    2010-09-15

    The aim of this study was to propose a novel automatic method for quantifying motor-tics caused by the Tourette Syndrome (TS). In this preliminary report, the feasibility of the monitoring process was tested over a series of standard clinical trials in a population of 12 subjects affected by TS. A wearable instrument with an embedded three-axial accelerometer was used to detect and classify motor tics during standing and walking activities. An algorithm was devised to analyze acceleration data by: eliminating noise; detecting peaks connected to pathological events; and classifying intensity and frequency of motor tics into quantitative scores. These indexes were compared with the video-based ones provided by expert clinicians, which were taken as the gold-standard. Sensitivity, specificity, and accuracy of tic detection were estimated, and an agreement analysis was performed through the least square regression and the Bland-Altman test. The tic recognition algorithm showed sensitivity = 80.8% ± 8.5% (mean ± SD), specificity = 75.8% ± 17.3%, and accuracy = 80.5% ± 12.2%. The agreement study showed that automatic detection tended to overestimate the number of tics occurred. Although, it appeared this may be a systematic error due to the different recognition principles of the wearable and video-based systems. Furthermore, there was substantial concurrency with the gold-standard in estimating the severity indexes. The proposed methodology gave promising performances in terms of automatic motor-tics detection and classification in a standard clinical context. The system may provide physicians with a quantitative aid for TS assessment. Further developments will focus on the extension of its application to everyday long-term monitoring out of clinical environments. © 2010 Movement Disorder Society.

  11. Oscillation experiments on Cesar and Marius - Experimental devices and measurement techniques

    International Nuclear Information System (INIS)

    Brunet, Max; Guerange, Jacques; Morier, Francis; Tonolli, Jacky

    1969-02-01

    An original method of measurement of effective cross sections of fissile materials has been developed by the CEA: a central fuel element of a critical experimental reactor is replaced by a sample containing the material to be studied. The replacement technique is based on oscillating the fuel load of the central channel. Signals are measured which are proportional to reactivity variation and to neutron density disturbance at the vicinity of the central channel, these variation and disturbance being produced by the sample oscillation. Measurements have been performed on experimental reactors (Minerve in Fontenay-aux-Roses, and Cesar and Marius in Cadarache). The authors herein describe the experimental devices and measurement techniques implemented in Marius and Cesar. In a first part, they describe the experimental devices which have been used during the three measurement campaigns (between 1965 and 1967). They report the study of measurement accuracies, and of some problems related to the use of the local detector [fr

  12. Development of technique for quantifying gamma emitters in metal waste. New technique of precise and automatic measurements for confirmation of clearance level of metal waste

    International Nuclear Information System (INIS)

    Hattori, Takatoshi

    2002-01-01

    A New technique of precise and automatic measurements of gamma emitters in metal waste has been developed using 3D non-contact shape measurement and monte-carlo calculation techniques in order to confirm that specific radioactivity level of metal waste satisfies the clearance level and furthermore the surface contamination level of the metal waste is below the legal standard level. The technique can give a calibration factor every measurement target automatically and realize an automatic correction for reduction of background count rate in gamma measurements due to self-shield effect of the measurement target. The accuracy of the present method has been made clear using mock-metal wastes with various types of shape, number and size. Assuming the goal of the detection limit for practical use is 25OBq in radioactivity, a concept of the practical gamma monitor has been designed so as to be able to confirm both the clearance level and surface contamination level simultaneously and to cope with the metal waste at a speed of 2-10 ton a day. (author)

  13. Sherlock: A Semi-automatic Framework for Quiz Generation Using a Hybrid Semantic Similarity Measure.

    Science.gov (United States)

    Lin, Chenghua; Liu, Dong; Pang, Wei; Wang, Zhe

    In this paper, we present a semi-automatic system (Sherlock) for quiz generation using linked data and textual descriptions of RDF resources. Sherlock is distinguished from existing quiz generation systems in its generic framework for domain-independent quiz generation as well as in the ability of controlling the difficulty level of the generated quizzes. Difficulty scaling is non-trivial, and it is fundamentally related to cognitive science. We approach the problem with a new angle by perceiving the level of knowledge difficulty as a similarity measure problem and propose a novel hybrid semantic similarity measure using linked data. Extensive experiments show that the proposed semantic similarity measure outperforms four strong baselines with more than 47 % gain in clustering accuracy. In addition, we discovered in the human quiz test that the model accuracy indeed shows a strong correlation with the pairwise quiz similarity.

  14. Equipment for thermal neutron flux measurements in reactor R2

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E; Nilsson, T; Claeson, S

    1960-04-15

    For most of the thermal neutron flux measurements in reactor R2 cobalt wires will be used. The loading and removal of these wires from the reactor core will be performed by means of a long aluminium tube and electromagnets. After irradiation the wires will be scanned in a semi-automatic device.

  15. Recommendations for blood pressure measuring devices for office/clinic use in low resource settings

    NARCIS (Netherlands)

    Parati, G.; Mendis, S.; Abegunde, D.; Asmar, R.; Mieke, S.; Murray, A.; Shengelia, B.; Steenvoorden, G.; Montfrans, G. van; O'Brien, E.

    2005-01-01

    This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/ clinic use in low resource settings. Blood pressure measuring devices to be used in

  16. Waveform measurement in mocrowave device characterization: impact on power amplifiers design

    Directory of Open Access Journals (Sweden)

    Roberto Quaglia

    2016-07-01

    Full Text Available This paper describes an example of a measurement setup enabling waveform measurements during the load-pull characterization of a microwave power device. The significance of this measurement feature is highlighted showing how waveform engineering can be exploited to design high efficiency microwave power amplifiers.

  17. On-line display used with cathode ray tube film measuring device

    International Nuclear Information System (INIS)

    Fortney, L.R.; Robertson, W.J.

    1981-01-01

    An improved display has been developed for use on our computer controlled measuring device (RIPPLE). The device features a television image of the film and a digital presentation on the same X, Y display. The television image is formed using a modified left and right raster scan which can cover 50% more area in the same time as the traditional raster

  18. An automatic controlled apparatus of target chamber for atomic spectra and level lifetime measurements

    International Nuclear Information System (INIS)

    Zhao Mengchun; Yang Zhihu

    1998-01-01

    An automatically controlled apparatus of target chamber was made to measure spectra of the excited atoms and lifetime of the excited levels. The hardware is composed of nine parts including a computer and a step-motor, while the software consists of three branch programs. The maximum movable distance of target position is 65 cm with a step-length of 8.3 μm and a precision of +- 18 μm per 2 mm. On account of simple structure and double protection, the apparatus exhibits flexibility and reliability in years service

  19. Precision alignment device

    Science.gov (United States)

    Jones, N.E.

    1988-03-10

    Apparatus for providing automatic alignment of beam devices having an associated structure for directing, collimating, focusing, reflecting, or otherwise modifying the main beam. A reference laser is attached to the structure enclosing the main beam producing apparatus and produces a reference beam substantially parallel to the main beam. Detector modules containing optical switching devices and optical detectors are positioned in the path of the reference beam and are effective to produce an electrical output indicative of the alignment of the main beam. This electrical output drives servomotor operated adjustment screws to adjust the position of elements of the structure associated with the main beam to maintain alignment of the main beam. 5 figs.

  20. Development of a microcontroller-based automatic control system for the electrohydraulic total artificial heart.

    Science.gov (United States)

    Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B

    1997-01-01

    An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.

  1. Surface photovoltage measurements and finite element modeling of SAW devices.

    Energy Technology Data Exchange (ETDEWEB)

    Donnelly, Christine

    2012-03-01

    Over the course of a Summer 2011 internship with the MEMS department of Sandia National Laboratories, work was completed on two major projects. The first and main project of the summer involved taking surface photovoltage measurements for silicon samples, and using these measurements to determine surface recombination velocities and minority carrier diffusion lengths of the materials. The SPV method was used to fill gaps in the knowledge of material parameters that had not been determined successfully by other characterization methods. The second project involved creating a 2D finite element model of a surface acoustic wave device. A basic form of the model with the expected impedance response curve was completed, and the model is ready to be further developed for analysis of MEMS photonic resonator devices.

  2. Automatic measurement and analysis of neonatal O2 consumption and CO2 production

    Science.gov (United States)

    Chang, Jyh-Liang; Luo, Ching-Hsing; Yeh, Tsu-Fuh

    1996-02-01

    It is difficult to estimate daily energy expenditure unless continuous O2 consumption (VO2) and CO2 production (VCO2) can be measured. This study describes a simple method for calculating daily and interim changes in O2 consumption and CO2 production for neonates, especially for premature infants. Oxygen consumption and CO2 production are measured using a flow-through technique in which the total VO2 and VCO2 over a given period of time are determined through a computerized system. This system can automatically calculate VO2 and VCO2 not only minute to minute but also over a period of time, e.g., 24 h. As a result, it provides a better indirect reflection of the accurate energy expenditure in an infant's daily life and can be used at the bedside of infants during their ongoing nursery care.

  3. 49 CFR 395.15 - Automatic on-board recording devices.

    Science.gov (United States)

    2010-10-01

    ... information concerning on-board system sensor failures and identification of edited data. Such support systems... driving today; (iv) Total hours on duty for the 7 consecutive day period, including today; (v) Total hours...-driver operation; (7) The on-board recording device/system identifies sensor failures and edited data...

  4. Simultaneous 3D-vibration measurement using a single laser beam device

    Science.gov (United States)

    Brecher, Christian; Guralnik, Alexander; Baümler, Stephan

    2012-06-01

    Today's commercial solutions for vibration measurement and modal analysis are 3D-scanning laser doppler vibrometers, mainly used for open surfaces in the automotive and aerospace industries and the classic three-axial accelerometers in civil engineering, for most industrial applications in manufacturing environments, and particularly for partially closed structures. This paper presents a novel measurement approach using a single laser beam device and optical reflectors to simultaneously perform 3D-dynamic measurement as well as geometry measurement of the investigated object. We show the application of this so called laser tracker for modal testing of structures on a mechanical manufacturing shop floor. A holistic measurement method is developed containing manual reflector placement, semi-automated geometric modeling of investigated objects and fully automated vibration measurement up to 1000 Hz and down to few microns amplitude. Additionally the fast set up dynamic measurement of moving objects using a tracking technique is presented that only uses the device's own functionalities and does neither require a predefined moving path of the target nor an electronic synchronization to the moving object.

  5. 77 FR 35745 - Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in...

    Science.gov (United States)

    2012-06-14

    ..., battery powered device with a semiconductor sensor. (2) Alcohol Countermeasure Systems Corp., submitted...-0062] Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in... Screening Devices to Measure Alcohol in Bodily Fluids dated, March 31, 2008 (73 FR 16956). DATES: Effective...

  6. Usefulness of semi-automatic volumetry compared to established linear measurements in predicting lymph node metastases in MSCT

    Energy Technology Data Exchange (ETDEWEB)

    Buerke, Boris; Puesken, Michael; Heindel, Walter; Wessling, Johannes (Dept. of Clinical Radiology, Univ. of Muenster (Germany)), email: buerkeb@uni-muenster.de; Gerss, Joachim (Dept. of Medical Informatics and Biomathematics, Univ. of Muenster (Germany)); Weckesser, Matthias (Dept. of Nuclear Medicine, Univ. of Muenster (Germany))

    2011-06-15

    Background Volumetry of lymph nodes potentially better reflect asymmetric size alterations independently of lymph node orientation in comparison to metric parameters (e.g. long-axis diameter). Purpose To distinguish between benign and malignant lymph nodes by comparing 2D and semi-automatic 3D measurements in MSCT. Material and Methods FDG-18 PET-CT was performed in 33 patients prior to therapy for malignant melanoma at stage III/IV. One hundred and eighty-six cervico-axillary, abdominal and inguinal lymph nodes were evaluated independently by two radiologists, both manually and with the use of semi-automatic segmentation software. Long axis (LAD), short axis (SAD), maximal 3D diameter, volume and elongation were obtained. PET-CT, PET-CT follow-up and/or histology served as a combined reference standard. Statistics encompassed intra-class correlation coefficients and ROC curves. Results Compared to manual assessment, semi-automatic inter-observer variability was found to be lower, e.g. at 2.4% (95% CI 0.05-4.8) for LAD. The standard of reference revealed metastases in 90 (48%) of 186 lymph nodes. Semi-automatic prediction of lymph node metastases revealed highest areas under the ROC curves for volume (reader 1 0.77, 95%CI 0.64-0.90; reader 2 0.76, 95%CI 0.59-0.86) and SAD (reader 1 0.76, 95%CI 0.64-0.88; reader 2 0.75, 95%CI 0.62-0.89). The findings for LAD (reader 1 0.73, 95%CI 0.60-0.86; reader 2 0.71, 95%CI 0.71, 95%CI 0.57-0.85) and maximal 3D diameter (reader 1 0.70, 95%CI 0.53-0.86; reader 2 0.76, 95%CI 0.50-0.80) were found substantially lower and for elongation (reader 1 0.65, 95%CI 0.50-0.79; reader 2 0.66, 95%CI 0.52-0.81) significantly lower (p < 0.05). Conclusion Semi-automatic analysis of lymph nodes in malignant melanoma is supported by high segmentation quality and reproducibility. As compared to established SAD, semi-automatic lymph node volumetry does not have an additive role for categorizing lymph nodes as normal or metastatic in malignant

  7. Design and Functional Validation of a Complex Impedance Measurement Device for Characterization of Ultrasonic Transducers

    International Nuclear Information System (INIS)

    De-Cock, Wouter; Cools, Jan; Leroux, Paul

    2013-06-01

    This paper presents the design and practical implementation of a complex impedance measurement device capable of characterization of ultrasonic transducers. The device works in the frequency range used by industrial ultrasonic transducers which is below the measurement range of modern high end network analyzers. The device uses the Goertzel algorithm instead of the more common FFT algorithm to calculate the magnitude and phase component of the impedance under test. A theoretical overview is given followed by a practical approach and measurement results. (authors)

  8. Cross-Device Tracking: Measurement and Disclosures

    Directory of Open Access Journals (Sweden)

    Brookman Justin

    2017-04-01

    Full Text Available Internet advertising and analytics technology companies are increasingly trying to find ways to link behavior across the various devices consumers own. This cross-device tracking can provide a more complete view into a consumer’s behavior and can be valuable for a range of purposes, including ad targeting, research, and conversion attribution. However, consumers may not be aware of how and how often their behavior is tracked across different devices. We designed this study to try to assess what information about cross-device tracking (including data flows and policy disclosures is observable from the perspective of the end user. Our paper demonstrates how data that is routinely collected and shared online could be used by online third parties to track consumers across devices.

  9. Device for the automatic X-ray testing of welded joints of pipes

    International Nuclear Information System (INIS)

    Ries, K.; Hannoschieck, K.; Rozic, K.M.; Basler, G.

    1979-01-01

    The notification flows of the tested pipes determined by the ultrasonic inspection are transmitted to the X-ray film automatic charger in the X-ray test room. The roll table for the pipes from the ultrasonic inspection to the X-ray test room is provided with an arrangement for weld detection and tube lathe, so that the X-ray films can be set on the corresponding spot by means of a cantilever. (RW) [de

  10. Design and development of semi-automatic radiation test and calibration facility

    International Nuclear Information System (INIS)

    Yadav, Ashok Kumar; Chouhan, V.K.; Narayan, Pradeep

    2008-01-01

    Semi-automatic gamma radiation test and calibration facility have been designed, developed and commissioned at Defence Laboratory Jodhpur (DLJ). The facility comprises of medium and high dose rate range setup using 30 Ci Cobalt-60 source, in a portable remotely operated Techops camera and a 15000 Ci 60 Co source in a Tele-therapy machine. The radiation instruments can be positioned at any desired position using a computer controlled positioner having three translational and one rotational motion. User friendly software helps in positioning the Device Under Test (DUT) at any desired dose rate or distance and acquire the data automatically. The servo and stepper motor controlled positioner helps in achieving the required precision and accuracy for the radiation calibration of the instruments. This paper describes the semi-automatic radiation test and calibration facility commissioned at DLJ. (author)

  11. An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

    International Nuclear Information System (INIS)

    Polee, C; Chankow, N; Srisatit, S; Thong-Aram, D

    2015-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking information of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a small detector. Application software was developed for Android mobile phone to remotely control the device and to display counting data via Bluetooth communication. Prior to film exposure, the device is placed behind a specimen to measure transmitted intensity which is inversely proportional to the exposure. Unlike in using the conventional exposure curve, correction factors for source decay, source-to- film distance, specimen thickness and kind of material are not needed. The developed technique and device make radiographic process economic, convenient and more reliable. (paper)

  12. Implantable optogenetic device with CMOS IC technology for simultaneous optical measurement and stimulation

    Science.gov (United States)

    Haruta, Makito; Kamiyama, Naoya; Nakajima, Shun; Motoyama, Mayumi; Kawahara, Mamiko; Ohta, Yasumi; Yamasaki, Atsushi; Takehara, Hiroaki; Noda, Toshihiko; Sasagawa, Kiyotaka; Ishikawa, Yasuyuki; Tokuda, Takashi; Hashimoto, Hitoshi; Ohta, Jun

    2017-05-01

    In this study, we have developed an implantable optogenetic device that can measure and stimulate neurons by an optical method based on CMOS IC technology. The device consist of a blue LED array for optically patterned stimulation, a CMOS image sensor for acquiring brain surface image, and eight green LEDs surrounding the CMOS image sensor for illumination. The blue LED array is placed on the CMOS image sensor. We implanted the device in the brain of a genetically modified mouse and successfully demonstrated the stimulation of neurons optically and simultaneously acquire intrinsic optical images of the brain surface using the image sensor. The integrated device can be used for simultaneously measuring and controlling neuronal activities in a living animal, which is important for the artificial control of brain functions.

  13. Geo-electric measurements – internal state of historic masonry

    OpenAIRE

    Schueremans, Luc

    2009-01-01

    A geophysical resistivity measuring device was modified to perform automatic monitoring of historical masonry structures before, during and after grout injection for consolidation purposes. The obtained image is called a geo-electrical tomography. The technique was used to evaluate the deteriorated masonry of the recently partly collapsed Maagdentoren in Zichem,(B). Geo-electric measuring techniques have been adapted from application in geology to be used as a non-destructive technique for t...

  14. Underwater radiation measuring device

    International Nuclear Information System (INIS)

    Seki, Noriyuki; Suzuki, Yasuo

    1998-01-01

    The present invention provides a device for measuring, under water, radiation from spent fuels (long members to be detected) of nuclear power plants and reprocessing facilities. Namely, a detecting insertion tube (insertion tube) is disposed so as to be in parallel with axial direction of the long member to be detected stored underwater. A γ-ray detector is inserted to the inside of the insertion tube. A driving mechanism is disposed for moving the γ-ray detector in axial direction inside of the insertion tube. The driving mechanism preferably has a system that it moves the γ-ray detector by winding a detection signal cable around a driving drum. The driving mechanism is formed by inserting and securing a driving tube having screws formed on the side surface and inserting it into the insertion tube. It may have a system of moving the γ-ray detector together with the driving tube while engaging the teeth of a driving transfer mechanism with the screws of the driving tube. (I.S.)

  15. Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices.

    Science.gov (United States)

    Pejović, Milić M; Denić, Dragan B; Pejović, Momčilo M; Nešić, Nikola T; Vasović, Nikola

    2010-10-01

    This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

  16. Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

    Energy Technology Data Exchange (ETDEWEB)

    Pejovic, Milic M.; Denic, Dragan B.; Pejovic, Momcilo M.; Nesic, Nikola T.; Vasovic, Nikola [Faculty of Electronic Engineering, University of Nis, Aleksandra Medvedeva 14, 18000 Nis (Serbia)

    2010-10-15

    This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

  17. Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

    International Nuclear Information System (INIS)

    Pejovic, Milic M.; Denic, Dragan B.; Pejovic, Momcilo M.; Nesic, Nikola T.; Vasovic, Nikola

    2010-01-01

    This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

  18. Device for the integral measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Micheron, Francois.

    1980-01-01

    This invention relates to devices for the integral determination of ionizing radiations, particularly to the construction of a portable dosemeter. Portable measuring instruments have been suggested in the past, particularly dosemeters in which the discharge of a capacitor under the action of ionizing radiations is measured. Since the charge of a capacitor is not stable owing to dielectric imperfections, these measuring instruments have to be recalibrated at frequent intervals. To overcome this drawback, the invention suggests using the discharge of an electret, electrically charged to a pre-set initial value, under the action of ionizing radiations, as the transducer means of a dosemeter used in conjunction with display or warning systems [fr

  19. Automatic Locker Key With Barcode Based Microcontroller Atmega 8535

    Science.gov (United States)

    Fahmi, M. Irfan; Efendi Hutagalung, Jhonson

    2017-12-01

    MCB (miniature circuit breaker) is an electromagnetic device that embodies complete enclosure in a molded insulating material. The main function of an MCB is to switch the circuit, i.e., to open the circuit (which has been connected to it) automatically when the current passing through it (MCB) exceeds the value for which it is set. Unlike fuse, an MCB can be easily reset and thus offers improved operational safety and greater convenience without incurring large operating cost.The principal of operation is simple. In simple terms MCB is a switch which automatically turns off when the current flowing through it passes the maximum allowable limit. Generally MCB are designed to protect against over current and over temperature faults (over heating). Sometimes the overload the current through the bimetal causes to raise the temperature of it. The heat generated within the bimetal itself enough to cause deflection due to thermal expansion of metals. This solution is used by LDR, and LM 35 as the sencor to control center. Therefore it is very important because it is related about local control switches, isolating switches against faults and overload protection devices for installations or specific equipments or appliances

  20. Device for automatically operating cooling mode of water in a pressure suppression chamber

    International Nuclear Information System (INIS)

    Sato, Hideyuki.

    1975-01-01

    Object: To provide a system for removing residual heat in a reactor safety system, which can automatically cool water in a pressure suppression chamber when a load on a generator is cut off, so as not to scram the reactor. Structure: When a load cut-off signal is generated by means of rapid closure of a turbine regulating valve or due to the load unbalance relay of generator output, or the like, a sea water pump is started to fully open an outlet valve for the sea water pump, a heat exchanging inlet valve and a minimum crow valve and to fully close a heat exchanging bypass valve. In this manner, cooling water for the heat exchanger is secured to start the pump in the system for removing residual heat, and when the pump discharge pressure is in normal condition, the inlet valve in pressure suppression chamber and the spray valve in the pressure suppression chamber are fully opened to automatically cool water in the pressure suppression chamber. (Hanada, M.)