WorldWideScience

Sample records for automated dose-dispensing scheme

  1. Towards more reliable automated multi-dose dispensing: retrospective follow-up study on medication dose errors and product defects.

    Science.gov (United States)

    Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko

    2013-03-01

    To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.

  2. Implementation and evaluation of an automated dispensing system.

    Science.gov (United States)

    Schwarz, H O; Brodowy, B A

    1995-04-15

    An institution's experience in replacing a traditional unit dose cassette-exchange system with an automated dispensing system is described. A 24-hour unit dose cassette-exchange system was replaced with an automated dispensing system (Pyxis's Medstation Rx) on a 36-bed cardiovascular surgery unit and an 8-bed cardiovascular intensive care unit. Significantly fewer missing doses were reported after Medstation Rx was implemented. No conclusions could be made about the impact of the system on the reporting of medication errors. The time savings for pharmacy associated with the filling, checking, and delivery of new medication orders equated to about 0.5 full-time equivalent (FTE). Medstation Rx also saved substantial nursing time for acquisition of controlled substances and for controlled-substance inventory taking at shift changes. A financial analysis showed that Medstation Rx could save the institution about $1 million over five years if all personnel time savings could be translated into FTE reductions. The automated system was given high marks by the nurses in a survey; 80% wanted to keep the system on their unit. Pilot implementation of an automated dispensing system improved the efficiency of drug distribution over that of the traditional unit dose cassette-exchange system.

  3. Dispensing error rate after implementation of an automated pharmacy carousel system.

    Science.gov (United States)

    Oswald, Scott; Caldwell, Richard

    2007-07-01

    A study was conducted to determine filling and dispensing error rates before and after the implementation of an automated pharmacy carousel system (APCS). The study was conducted in a 613-bed acute and tertiary care university hospital. Before the implementation of the APCS, filling and dispensing rates were recorded during October through November 2004 and January 2005. Postimplementation data were collected during May through June 2006. Errors were recorded in three areas of pharmacy operations: first-dose or missing medication fill, automated dispensing cabinet fill, and interdepartmental request fill. A filling error was defined as an error caught by a pharmacist during the verification step. A dispensing error was defined as an error caught by a pharmacist observer after verification by the pharmacist. Before implementation of the APCS, 422 first-dose or missing medication orders were observed between October 2004 and January 2005. Independent data collected in December 2005, approximately six weeks after the introduction of the APCS, found that filling and error rates had increased. The filling rate for automated dispensing cabinets was associated with the largest decrease in errors. Filling and dispensing error rates had decreased by December 2005. In terms of interdepartmental request fill, no dispensing errors were noted in 123 clinic orders dispensed before the implementation of the APCS. One dispensing error out of 85 clinic orders was identified after implementation of the APCS. The implementation of an APCS at a university hospital decreased medication filling errors related to automated cabinets only and did not affect other filling and dispensing errors.

  4. Health care professionals’ perspectives on automated multi-dose drug dispensing

    Directory of Open Access Journals (Sweden)

    Bardage C

    2014-12-01

    Full Text Available Background: During the 1980s, manual repackaging of multi-dose medications from pharmacies in Sweden was successively substituted with automated multi-dose drug dispensing (MDD. There are few studies evaluating the consequences of automated MDD with regard to patient safety, and those that investigate this issue are not very extensive. Objectives: To investigate Swedish health care professionals’ perceived experience of automated MDD and its effects on patient adherence and patient safety. Methods: Three questionnaire forms, one for physicians, nurses, and assistant nurses/nursing assistants, were developed based on reviews of the literature and pilot testing of the questions in the intended target groups. The target groups were health professionals prescribing or administrating MDD to patients. A sample (every sixth municipality was drawn from the sampling frame of Swedish municipalities, resulting in 40 municipalities, about 14% of all municipalities in Sweden. Email addresses of general practitioners were obtained from county councils, while the municipalities assisted in getting contact details for nurses, assistant nurses and nursing assistants. A total of 915 questionnaires were distributed electronically to physicians, 515 to nurses, and 4,118 to assistant nurses/nursing assistants. The data were collected in September and October 2012. Results: The response rate among physicians, nurses and assistant nurses/nursing assistants was 31%, 43% and 23%, respectively. The professionals reported that automated MDD reduces duplication of medication, contributes to correct dosages, helps patients take their medication at the right time, and reduces confusion among patients. Fifteen per cent of the physicians and about one-third of the nurses and assistant nurses/nursing assistants reported that generic substitution makes it more difficult for the patient to identify the various medicines available in the sachets. The physicians did, however

  5. The impact of automation on workload and dispensing errors in a hospital pharmacy.

    Science.gov (United States)

    James, K Lynette; Barlow, Dave; Bithell, Anne; Hiom, Sarah; Lord, Sue; Pollard, Mike; Roberts, Dave; Way, Cheryl; Whittlesea, Cate

    2013-04-01

    To determine the effect of installing an original-pack automated dispensing system (ADS) on dispensary workload and prevented dispensing incidents in a hospital pharmacy. Data on dispensary workload and prevented dispensing incidents, defined as dispensing errors detected and reported before medication had left the pharmacy, were collected over 6 weeks at a National Health Service hospital in Wales before and after the installation of an ADS. Workload was measured by non-participant observation using the event recording technique. Prevented dispensing incidents were self-reported by pharmacy staff on standardised forms. Median workloads (measured as items dispensed/person/hour) were compared using Mann-Whitney U tests and rate of prevented dispensing incidents were compared using Chi-square test. Spearman's rank correlation was used to examine the association between workload and prevented dispensing incidents. A P value of ≤0.05 was considered statistically significant. Median dispensary workload was significantly lower pre-automation (9.20 items/person/h) compared to post-automation (13.17 items/person/h, P automation (0.28%) than pre-automation (0.64%, P automation (ρ = 0.23, P automation improves dispensing efficiency and reduces the rate of prevented dispensing incidents. It is proposed that prevented dispensing incidents frequently occurred during periods of high workload due to involuntary automaticity. Prevented dispensing incidents occurring after a busy period were attributed to staff experiencing fatigue after-effects. © 2012 The Authors. IJPP © 2012 Royal Pharmaceutical Society.

  6. Automated drug dispensing system reduces medication errors in an intensive care setting.

    Science.gov (United States)

    Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick

    2010-12-01

    We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; perror (20.4% and 13.5%; perror showed a significant impact of the automated dispensing system in reducing preparation errors (perrors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.

  7. Development of automated blender and dispensing system

    International Nuclear Information System (INIS)

    Kulkarni, Anupama; Aherwal, P.; Patil, C.B.

    2014-01-01

    This paper describes automated blender and dispensing system designed and developed in Nuclear Recycle Board for its reprocessing plant. Obtaining sinterable grade oxide powder from the product solution received in the heavy metal product line involves skilled manpower and time consuming, laborious manual operations. Entire treatment is carried out in a train of closed containments called as glove boxes. In view of this Automated blender and dispensing system has been developed to reduce tedious manual operations. System consists of PLC based control system to drive motorised charging mechanism, a conical ribbon blender which homogenises the product and load cell triggered, indexing dispensing mechanism. Schematic design of the system has been done in-house, while fabrication was outsourced. System has been built, tested and installed at component test facility (CTF) at Tarapur. Actual blending tests were carried out by using dummy material like calcium carbonate and barium carbonate powder, with different sets of parameter. Blended product was chemically analysed for its homogeneity. System has now been put to trial runs by operating staff. This development has circumvented tedious operations of Scooping and increased the throughput. This paper describes challenges in undertaking this developmental work. (author)

  8. Operating experience of an automated TLD dispensing system at CORAL facility

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Arun, R.; Yuvaraj, N.; Karthikeyan, D.; Dheeraj, R.; Akila, R.; Santhanam, R.; Rajagopal, V.; Kumar, Amudhu Ramesh

    2016-01-01

    Monitoring of exposures to occupational workers on individual basis is a regulatory requirement to demonstrate compliance that the dose to the workers is well within the dose limit. Over three decades for monitoring of external exposures, CaSO 4 based Thermo luminescence dosimeters (TLDs), which exhibit the required accuracy, reliability and ruggedness have been employed. TLD cards with unique identification number are loaded in plastic cassettes along with photographs are placed in wooden racks at the entry of the controlled area of the plant. However, there is always a chance that a TLD may be misplaced, used by others or there could be a deliberate act of misuse or abuse. To circumvent this it was decided to install an automated TLD dispensing system with individual TLD tracking as well as locking arrangement. CORAL reprocessing facility at IGCAR was the first to install one such system at Kalpakkam and the operating experience of the system for the last two years is brought out in this paper

  9. Impact of an automated dispensing system in outpatient pharmacies.

    Science.gov (United States)

    Humphries, Tammy L; Delate, Thomas; Helling, Dennis K; Richardson, Bruce

    2008-01-01

    To evaluate the impact of an automated dispensing system (ADS) on pharmacy staff work activities and job satisfaction. Cross-sectional, retrospective study. Kaiser Permanente Colorado (KPCO) outpatient pharmacies in September 2005. Pharmacists and technicians from 18 outpatient pharmacies. All KPCO outpatient pharmacists (n = 136) and technicians (n = 160) were surveyed regarding demographics and work activities and pharmacist job satisfaction. Work activities and job satisfaction were compared between pharmacies with and without ADS. Historical prescription purchase records from ADS pharmacies were assessed for pre-ADS to post-ADS changes in productivity. Self-reported pharmacy staff work activities and pharmacist job satisfaction. Pharmacists who responded to the demographic questionnaire (n = 74) were primarily women (60%), had a bachelor's degree in pharmacy (68%), and had been in practice for 10 years or more (53%). Responding technicians (n = 72) were predominantly women (80%) with no postsecondary degree (90%) and fewer than 10 years (68%) in practice. Pharmacists in ADS pharmacies who responded to the work activities questionnaire (n = 50) reported equivalent mean hours spent in patient care activities and filling medication orders compared with non-ADS pharmacists (n = 33; P > 0.05). Similarly, technicians in ADS pharmacies who responded to the work activities questionnaire (n = 64) reported equivalent mean hours spent in filling medication orders compared with non-ADS technicians (n = 38; P > 0.05). An equivalent proportion of ADS pharmacists reported satisfaction with their current job compared with non-ADS pharmacies (P > 0.05). Mean productivity did not increase appreciably after automation (P >0.05). By itself, installing an ADS does not appear to shift pharmacist work activities from dispensing to patient counseling or to increase job satisfaction. Shifting pharmacist work activities from dispensing to counseling and monitoring drug therapy outcomes

  10. Multi-dose drug dispensing is a challenge across the primary-secondary care interface

    DEFF Research Database (Denmark)

    Reuther, Lene Orskov; Lysen, Charlotte; Faxholm, Mette

    2011-01-01

    Multi-dose drug dispensing (MDDD) signifies that the patient's medicine is packed in disposable bags corresponding to the dose that should be taken. The purpose of the present study was to investigate how a hospital MDDD instruction was followed.......Multi-dose drug dispensing (MDDD) signifies that the patient's medicine is packed in disposable bags corresponding to the dose that should be taken. The purpose of the present study was to investigate how a hospital MDDD instruction was followed....

  11. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  12. Dose dispenser for radioactive gas

    International Nuclear Information System (INIS)

    Horwitz, N.H.; Gutkowski, R.E.

    1977-01-01

    An activity metering apparatus for metering predetermined activities of radioactive gas from a supply ampul to dose vials is described. The apparatus includes a shielded ampul housing, a fine metering valve communicating with the ampul housing chamber, a shielded vial housing and a hypodermic needle communicating with the metering valve and received through an opening in the vial housing. A Geiger-Muller tube is adjustably supported opposite an opening in the vial housing, whereby the activity of the radioactive gas dispensed to a partially evacuated vial within the vial chamber may be read directly by a standard laboratory rate meter

  13. Medication Incidents Related to Automated Dose Dispensing in Community Pharmacies and Hospitals - A Reporting System Study

    Science.gov (United States)

    Cheung, Ka-Chun; van den Bemt, Patricia M. L. A.; Bouvy, Marcel L.; Wensing, Michel; De Smet, Peter A. G. M.

    2014-01-01

    Introduction Automated dose dispensing (ADD) is being introduced in several countries and the use of this technology is expected to increase as a growing number of elderly people need to manage their medication at home. ADD aims to improve medication safety and treatment adherence, but it may introduce new safety issues. This descriptive study provides insight into the nature and consequences of medication incidents related to ADD, as reported by healthcare professionals in community pharmacies and hospitals. Methods The medication incidents that were submitted to the Dutch Central Medication incidents Registration (CMR) reporting system were selected and characterized independently by two researchers. Main Outcome Measures Person discovering the incident, phase of the medication process in which the incident occurred, immediate cause of the incident, nature of incident from the healthcare provider's perspective, nature of incident from the patient's perspective, and consequent harm to the patient caused by the incident. Results From January 2012 to February 2013 the CMR received 15,113 incidents: 3,685 (24.4%) incidents from community pharmacies and 11,428 (75.6%) incidents from hospitals. Eventually 1 of 50 reported incidents (268/15,113 = 1.8%) were related to ADD; in community pharmacies more incidents (227/3,685 = 6.2%) were related to ADD than in hospitals (41/11,428 = 0.4%). The immediate cause of an incident was often a change in the patient's medicine regimen or relocation. Most reported incidents occurred in two phases: entering the prescription into the pharmacy information system and filling the ADD bag. Conclusion A proportion of incidents was related to ADD and is reported regularly, especially by community pharmacies. In two phases, entering the prescription into the pharmacy information system and filling the ADD bag, most incidents occurred. A change in the patient's medicine regimen or relocation was the immediate causes of an incident

  14. Communicating doses of pediatric liquid medicines to parents/caregivers: a comparison of written dosing directions on prescriptions with labels applied by dispensed pharmacy.

    Science.gov (United States)

    Shah, Rita; Blustein, Leona; Kuffner, Ed; Davis, Lisa

    2014-03-01

    To identify and compare volumetric measures used by healthcare providers in communicating dosing instructions for pediatric liquid prescriptions to parents/caregivers. Dosing instructions were retrospectively reviewed for the 10 most frequently prescribed liquid medications dispensed from 4 community pharmacies for patients aged ≤ 12 years during a 3-month period. Volumetric measures on original prescriptions (ie, milliliters, teaspoons) were compared with those utilized by the pharmacist on the pharmacy label dispensed to the parent/caregiver. Of 649 prescriptions and corresponding pharmacy labels evaluated, 68% of prescriptions and 62% of pharmacy labels communicated dosing in milliliters, 24% of prescriptions and 29% of pharmacy labels communicated dosing in teaspoonfuls, 7% of prescriptions and 0% of pharmacy labels communicated dosing in other measures (ie, milligrams, cubic centimeters, "dose"), and 25% of dispensed pharmacy labels did not reflect units as written in the prescription. Volumetric measures utilized by healthcare professionals in dosing instructions for prescription pediatric oral liquid medications are not consistent. Healthcare professionals and parents/caregivers should be educated on safe dosing practices for liquid pediatric medications. Generalizability to the larger pediatric population may vary depending on pharmacy chain, location, and medications evaluated. Copyright © 2014 Mosby, Inc. All rights reserved.

  15. Impact of one-dose package dispensing with patient counseling on medication adherence in geriatrics suffering from chronic disorders

    Directory of Open Access Journals (Sweden)

    Narayana Goruntla

    2018-01-01

    Full Text Available Introduction: Medication nonadherence in elderly patients could result in a waste of medical expenses in a long-time span as well as deterioration of the patient's medical condition. Aim: The aim of this study is to evaluate the impact of one-dose package dispensing with patient counseling on medication adherence among elderly patients suffering from chronic disorders. Settings and Design: This is prospective, open-labeled, randomized trial carried out at dispensing pharmacy of the secondary care referral hospital, located in resource-limited settings of Anantapur District, Andhra Pradesh, India. Subjects and Methods: A total of 330 (aged ≥60 years patients were randomly assigned to one of three study groups: Group A (n = 110, no change in dosing and packing; Group B (n = 110, one-dose package dispensing; Group C (n = 110, One-dose package dispensing with patient counseling. Medication adherence levels were measured using a pill count and visual analog scale (VAS method at baseline and follow-up (after 1 month. Statistical Analysis: Descriptive statistics were used to represent the sociodemographic, clinical, and medication adherence profile of study participants. One-way ANOVA test is used to assess significant differences between three groups with a P 60 years who are on multiple medications can benefit from one-dose package dispensing and appropriate counseling. This will improve medication adherence hence better outcomes.

  16. Advanced Medication Dispenser

    Directory of Open Access Journals (Sweden)

    A.I. Alexan

    2013-12-01

    Full Text Available Medication dispensing is an important activity that can have major implications if done improperly. Dispensing must be done in the correct time interval, at the correct user, with the correct drug and dose. We propose a smart medication dispenser that can satisfy these needs and provide a mechanism for supervision. In order to ensure that the dispensing process is error free, the concept of a new smart medication container is used. A smart medication container is “smart” as it holds the medication dispensing parameters for the drugs it contains: dispensing time and date and name. Based on this information, the actual dispensing is done.

  17. Population prevalence of high dose paracetamol in dispensed paracetamol/opioid prescription combinations: an observational study

    Science.gov (United States)

    2012-01-01

    Background Paracetamol (acetaminophen) is generally considered a safe medication, but is associated with hepatotoxicity at doses above doses of 4.0 g/day, and even below this daily dose in certain populations. Methods The Nova Scotia Prescription Monitoring Program (NSPMP) in the Canadian province of Nova Scotia is a legislated organization that collects dispensing information on all out-of-hospital prescription controlled drugs dispensed for all Nova Scotia residents. The NSPMP provided data to track all paracetamol/opioids redeemed by adults in Nova Scotia, from July 1, 2005 to June 30, 2010. Trends in the number of adults dispensed these prescriptions and the numbers of prescriptions and tablets dispensed over this period were determined. The numbers and proportions of adults who filled prescriptions exceeding 4.0 g/day and 3.25 g/day were determined for the one-year period July 1, 2009 to June 30, 2010. Data were stratified by sex and age (paracetamol/opioid prescription was lower in each successive one-year period. From July 2009 to June 2010, one in 12 adults (n = 59,197) filled prescriptions for over 13 million paracetamol/opioid tablets. Six percent (n = 3,786) filled prescriptions that exceeded 4.0 g/day and 18.6% (n = 11,008) exceeded 3.25 g/day of paracetamol at least once. These findings exclude non-prescription paracetamol and paracetamol–only prescribed medications. Conclusions A substantial number of individuals who redeem prescriptions for paracetamol/opioid combinations may be at risk of paracetamol-related hepatotoxicity. Healthcare professionals must be vigilant when prescribing and dispensing these medications in order to reduce the associated risks. PMID:22709372

  18. Impact assessment of an automated drug-dispensing system in a tertiary hospital

    Directory of Open Access Journals (Sweden)

    Débora de-Carvalho

    Full Text Available OBJECTIVE: To evaluate the costs and patient safety of a pilot implementation of an automated dispensing cabinet in a critical care unit of a private tertiary hospital in São Paulo/Brazil. METHODS: This study considered pre- (January-August 2013 and post- (October 2013-October 2014 intervention periods. We considered the time and cost of personnel, number of adverse events, audit adjustments to patient bills, and urgent requests and returns of medications to the central pharmacy. Costs were evaluated based on a 5-year analytical horizon and are reported in Brazilian Reals (R$ and US dollars (USD. RESULTS: The observed decrease in the mean number of events reported with regard to the automated drug-dispensing system between pre- and post-implementation periods was not significant. Importantly, the numbers are small, which limits the power of the mean comparative analysis between the two periods. A reduction in work time was observed among the nurses and administrative assistants, whereas pharmacist assistants showed an increased work load that resulted in an overall 6.5 hours of work saved/day and a reduction of R$ 33,598 (USD 14,444 during the first year. The initial investment (R$ 206,065; USD 88,592 would have been paid off in 5 years considering only personnel savings. Other findings included significant reductions of audit adjustments to patient hospital bills and urgent requests and returns of medications to the central pharmacy. CONCLUSIONS: Evidence of the positive impact of this technology on personnel time and costs and on other outcomes of interest is important for decision making by health managers.

  19. Automation of the control scheme for IUAC Linac

    International Nuclear Information System (INIS)

    Sahu, B.K.; Dutt, R.N.; Antony, J.; Mathuria, D.S.; Pandey, A.; Singh, K.; Ahuja, R.; Chowdhury, G.K.; Rai, A.; Patra, P.; Ghosh, S.; Ajithkumar, B.P.; Kanjilal, D.; Roy, A.

    2011-01-01

    Improvement of the Linac control scheme is undertaken for automation with minimum human intervention during beam acceleration. Python language interface with the present control scheme is used in writing automation routines to monitor the status of the phase/amplitude lock during operation and shut-down the locking mechanism to reduce the RF power, if required. Simultaneous pulse conditioning of the resonators is made possible by using dedicated hardware interfaced and Python based client interface. Movement of the drive coupler is enabled from operation console with position read back. The manual control of the slow-tuner electronics module to bring the frequency close to reference during phase locking is interfaced with the present control scheme for remote operation. Monitoring of amplitude and absolute phase of each cavity is made possible from operation console. An alternate tuning mechanism using piezoelectric actuator and stepper motor combination has been successfully tested in the test cryostat. (author)

  20. PS-022 Complex automated medication systems reduce medication administration error rates in an acute medical ward

    DEFF Research Database (Denmark)

    Risør, Bettina Wulff; Lisby, Marianne; Sørensen, Jan

    2017-01-01

    Background Medication errors have received extensive attention in recent decades and are of significant concern to healthcare organisations globally. Medication errors occur frequently, and adverse events associated with medications are one of the largest causes of harm to hospitalised patients...... cabinet, automated dispensing and barcode medication administration; (2) non-patient specific automated dispensing and barcode medication administration. The occurrence of administration errors was observed in three 3 week periods. The error rates were calculated by dividing the number of doses with one...

  1. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    Energy Technology Data Exchange (ETDEWEB)

    Said, M. A.; Suhaimi, N. E. F. [Fakulti Sains dan Teknologi, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi Selangor (Malaysia); Ashhar, Z. N., E-mail: aminhpj@gmail.com [Institut Kanser Negara, No 4, Jalan P7, Presint 7, 62250 Putrajaya (Malaysia); Zainon, R. [Advanced Medical & Dental Institute, Universiti Sains Malaysia, Bertam, 13200, Kepala Batas, Pulau Pinang (Malaysia)

    2016-01-22

    In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

  2. Twenty-year trends in benzodiazepine dispensing in the Australian population.

    Science.gov (United States)

    Islam, M M; Conigrave, K M; Day, C A; Nguyen, Y; Haber, P S

    2014-01-01

    Considerable concern has been expressed about overprescribing of benzodiazepines and related harms. Past analyses have relied on World Health Organization-defined daily doses (DDD) which are sometimes out of keeping with clinical usage. This study examines 20-year (1992-2011) trends of benzodiazepine dispensing in Australia using both DDD and Ashton equivalent dose. Data from the Drug Utilisation Sub-Committee and the Pharmaceutical Benefits Scheme (PBS) website were analysed. Trends in number of prescriptions, DDD/1000 people/day and DDD/prescription were examined over time, and between states/territories. In the 20-year period, 174 080 904 scripts were recorded, with temazepam the most dispensed benzodiazepine (35% of scripts), followed by diazepam (23%). Overall recorded utilisation fell from 27.7 DDD/1000 people/day in 1992 to 20.8 in 2011 (24.9% decrease). There were striking changes in use of individual benzodiazepines over time, with reductions in oxazepam and flunitrazepam and dramatic increases in alprazolam. Since 1998, there has been a steady increase, albeit modest, in per script DDD. The DDD/1000 people/day for items dispensed through PBS/Repatriaton-PBS was highest in Tasmania and lowest in Northern Territory. Despite a modest overall decline in the amount of benzodiazepine dispensed, the level of use is still likely to reflect relative over-prescribing given the paucity of accepted indications for long-term use. Since 1998, there was a polynomial increase in quantity dispensed per script. The WHO-defined DDD for clonazepam seems inappropriate and could impede monitoring of its abuse. Other problems include lack of national data for medications not subsidised on PBS/Repatriation PBS. A broad policy approach is required, not one which targets only one particular benzodiazepine. © 2013 The Authors; Internal Medicine Journal © 2013 Royal Australasian College of Physicians.

  3. Automated extraction of radiation dose information from CT dose report images.

    Science.gov (United States)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2011-06-01

    The purpose of this article is to describe the development of an automated tool for retrieving texts from CT dose report images. Optical character recognition was adopted to perform text recognitions of CT dose report images. The developed tool is able to automate the process of analyzing multiple CT examinations, including text recognition, parsing, error correction, and exporting data to spreadsheets. The results were precise for total dose-length product (DLP) and were about 95% accurate for CT dose index and DLP of scanned series.

  4. A compact 133Xe gas dispenser

    International Nuclear Information System (INIS)

    Hawkins, T.; Harris, R.

    1977-01-01

    A dispenser for 133 Xe gas is described which is compact and simple to use, allowing the xenon to be dispensed from it shipping ampoule to suitable multi-dose injection vials in a controlled manner and with a high degree of operator safety. The apparatus has no joints and only a single rubber teat, minimizing the risks of adsorption and leakage. A scaled drawing of the dispenser is shown. (U.K.)

  5. Safe pill-dispensing.

    Science.gov (United States)

    Testa, Massimiliano; Pollard, John

    2007-01-01

    Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.

  6. Automation of radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaguchi, Chisato; Yamada, Hideo; Iio, Masahiro

    1974-01-01

    Automation systems for measuring Australian antigen by radioimmunoassay under development were discussed. Samples were processed as follows: blood serum being dispensed by automated sampler to the test tube, and then incubated under controlled time and temperature; first counting being omitted; labelled antibody being dispensed to the serum after washing; samples being incubated and then centrifuged; radioactivities in the precipitate being counted by auto-well counter; measurements being tabulated by automated typewriter. Not only well-type counter but also position counter was studied. (Kanao, N.)

  7. A scheme for a future distribution automation system in Finnish utilities

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M.; Kaerkkaeinen, S. [VTT Energy, Espoo (Finland); Partanen, J. [Lappeenranta Univ. of Technology (Finland)

    1996-12-31

    This presentation summarizes the results of a project, the aim of which was to define the optimal set of functions for the future distribution automation (DA) systems in Finland. The general factors. which affect the automation needs, are first discussed. The benefits of various functions of DA and demand side management (DSM) are then studied. Next a computer model for a DA feasibility analysis is presented, and some computation results are given. From these. the proposed automation scheme is finally concluded

  8. A scheme for a future distribution automation system in Finnish utilities

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M; Kaerkkaeinen, S [VTT Energy, Espoo (Finland); Partanen, J [Lappeenranta Univ. of Technology (Finland)

    1998-08-01

    This presentation summarizes the results of a project, the aim of which was to define the optimal set of functions for the future distribution automation (DA) systems in Finland. The general factors, which affect the automation needs, are first discussed. The benefits of various functions of DA and demand side management (DSM) are then studied. Next a computer model for a DA feasibility analysis is presented, and some computation results are given. From these, the proposed automation scheme is finally concluded

  9. A scheme for a future distribution automation system in Finnish utilities

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M; Kaerkkaeinen, S [VTT Energy, Espoo (Finland); Partanen, J [Lappeenranta Univ. of Technology (Finland)

    1997-12-31

    This presentation summarizes the results of a project, the aim of which was to define the optimal set of functions for the future distribution automation (DA) systems in Finland. The general factors. which affect the automation needs, are first discussed. The benefits of various functions of DA and demand side management (DSM) are then studied. Next a computer model for a DA feasibility analysis is presented, and some computation results are given. From these. the proposed automation scheme is finally concluded

  10. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    Science.gov (United States)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  11. The NRPB's new dosimeter and dose record keeping services

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1976-01-01

    A new automated dosimeter and record keeping service which the National Radiological Protection Board (UK) intends to introduce in 1977 is described. The automated system, based on a thermoluminescent dosimeter, will be linked to a fully computerised record keeping system with automatic printing of dose records and Transfer Records operated at its Headquarters at Harwell. The new system will dispense with much manual labour which in the past has introduced inevitable errors and incurred increasing costs. (U.K.)

  12. An automated dose tracking system for adaptive radiation therapy.

    Science.gov (United States)

    Liu, Chang; Kim, Jinkoo; Kumarasiri, Akila; Mayyas, Essa; Brown, Stephen L; Wen, Ning; Siddiqui, Farzan; Chetty, Indrin J

    2018-02-01

    The implementation of adaptive radiation therapy (ART) into routine clinical practice is technically challenging and requires significant resources to perform and validate each process step. The objective of this report is to identify the key components of ART, to illustrate how a specific automated procedure improves efficiency, and to facilitate the routine clinical application of ART. Data was used from patient images, exported from a clinical database and converted to an intermediate format for point-wise dose tracking and accumulation. The process was automated using in-house developed software containing three modularized components: an ART engine, user interactive tools, and integration tools. The ART engine conducts computing tasks using the following modules: data importing, image pre-processing, dose mapping, dose accumulation, and reporting. In addition, custom graphical user interfaces (GUIs) were developed to allow user interaction with select processes such as deformable image registration (DIR). A commercial scripting application programming interface was used to incorporate automated dose calculation for application in routine treatment planning. Each module was considered an independent program, written in C++or C#, running in a distributed Windows environment, scheduled and monitored by integration tools. The automated tracking system was retrospectively evaluated for 20 patients with prostate cancer and 96 patients with head and neck cancer, under institutional review board (IRB) approval. In addition, the system was evaluated prospectively using 4 patients with head and neck cancer. Altogether 780 prostate dose fractions and 2586 head and neck cancer dose fractions went processed, including DIR and dose mapping. On average, daily cumulative dose was computed in 3 h and the manual work was limited to 13 min per case with approximately 10% of cases requiring an additional 10 min for image registration refinement. An efficient and convenient

  13. Nursing perception of the impact of automated dispensing cabinets on patient safety and ergonomics in a teaching health care center.

    Science.gov (United States)

    Rochais, Elise; Atkinson, Suzanne; Guilbeault, Mélanie; Bussières, Jean-François

    2014-04-01

    To evaluate how nursing staff felt about the impact of automated dispensing cabinets (ADCs) on the safe delivery of health care and workplace ergonomics. To identify the main issues involved in the use of this technology and to describe the corrective measures implemented. Cross-sectional descriptive study with quantitative and qualitative components. A questionnaire that consisted of 33 statements about ADC was distributed from May 24 to June 3, 2011. A total of 172 (46%) of 375 nurses completed the questionnaire. Nursing staff considered the introduction of ADC made their work easier (level of agreement of 90%), helped to safely provide patients with care (91%), and helped to reduce medication incidents/accidents (81%). Nursing staff was particularly satisfied by the narcotic drugs management with the ADCs. Nursing staff were not satisfied with the additional delays in the preparation and administration of a medication dose and the inability to prevent a medication from being administered when stopped on the medication administration record (48%). The nursing staff members were satisfied with the use of ADC and believed it made their work easier, promoted safe patient care, and were perceived to reduce medication incidents/accidents.

  14. Systems automated reporting of patient dose in digital radiology

    International Nuclear Information System (INIS)

    Collado Chamorro, P.; Sanz Freire, C. J.; Martinez Mirallas, O.; Tejada San Juan, S.; Lopez de Gammarra, M. S.

    2013-01-01

    It has developed a procedure automated reporting of doses to patients in Radiology. This procedure allows to save the time required of the data used to calculate the dose to patients by yields. Also saves the time spent in the transcription of these data for the realization of the necessary calculations. This system has been developed using open source software. The characteristics of the systems of digital radiography for the automation of procedures, in particular the registration of dose should benefit from patient. This procedure is validated and currently in use at our institution. (Author)

  15. Disruptive innovation in community pharmacy - Impact of automation on the pharmacist workforce.

    Science.gov (United States)

    Spinks, Jean; Jackson, John; Kirkpatrick, Carl M; Wheeler, Amanda J

    Pharmacy workforce planning has been relatively static for many decades. However, like all industries, health care is exposed to potentially disruptive technological changes. Automated dispensing systems have been available to pharmacy for over a decade and have been applied to a range of repetitive technical processes which are at risk of error, including record keeping, item selection, labeling and dose packing. To date, most applications of this technology have been at the local level, such as hospital pharmacies or single-site community pharmacies. However, widespread implementation of a more centralized automated dispensing model, such as the 'hub and spoke' model currently being debated in the United Kingdom, could cause a 'technology shock,' delivering industry-wide efficiencies, improving medication accessibility and lowering costs to consumers and funding agencies. Some of pharmacists' historical roles may be made redundant, and new roles may be created, decoupling pharmacists to a certain extent from the dispensing and supply process. It may also create an additional opportunity for pharmacists to be acknowledged and renumerated for professional services that extend beyond the dispensary. Such a change would have significant implications for the organization and funding of community pharmacy services as well as pharmacy workforce planning. This paper discusses the prospect of centralized automated dispensing systems and how this may impact on the pharmacy workforce. It concludes that more work needs to be done in the realm of pharmacy workforce planning to ensure that the introduction of any new technology delivers optimal outcomes to consumers, insurers and the pharmacy workforce. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440... stacking device is a device intended for medical purposes to dispense a microbiological culture medium into...

  17. Recent advances in inkjet dispensing technologies: applications in drug discovery.

    Science.gov (United States)

    Zhu, Xiangcheng; Zheng, Qiang; Yang, Hu; Cai, Jin; Huang, Lei; Duan, Yanwen; Xu, Zhinan; Cen, Peilin

    2012-09-01

    Inkjet dispensing technology is a promising fabrication methodology widely applied in drug discovery. The automated programmable characteristics and high-throughput efficiency makes this approach potentially very useful in miniaturizing the design patterns for assays and drug screening. Various custom-made inkjet dispensing systems as well as specialized bio-ink and substrates have been developed and applied to fulfill the increasing demands of basic drug discovery studies. The incorporation of other modern technologies has further exploited the potential of inkjet dispensing technology in drug discovery and development. This paper reviews and discusses the recent developments and practical applications of inkjet dispensing technology in several areas of drug discovery and development including fundamental assays of cells and proteins, microarrays, biosensors, tissue engineering, basic biological and pharmaceutical studies. Progression in a number of areas of research including biomaterials, inkjet mechanical systems and modern analytical techniques as well as the exploration and accumulation of profound biological knowledge has enabled different inkjet dispensing technologies to be developed and adapted for high-throughput pattern fabrication and miniaturization. This in turn presents a great opportunity to propel inkjet dispensing technology into drug discovery.

  18. Effects of sparse sampling schemes on image quality in low-dose CT

    International Nuclear Information System (INIS)

    Abbas, Sajid; Lee, Taewon; Cho, Seungryong; Shin, Sukyoung; Lee, Rena

    2013-01-01

    Purpose: Various scanning methods and image reconstruction algorithms are actively investigated for low-dose computed tomography (CT) that can potentially reduce a health-risk related to radiation dose. Particularly, compressive-sensing (CS) based algorithms have been successfully developed for reconstructing images from sparsely sampled data. Although these algorithms have shown promises in low-dose CT, it has not been studied how sparse sampling schemes affect image quality in CS-based image reconstruction. In this work, the authors present several sparse-sampling schemes for low-dose CT, quantitatively analyze their data property, and compare effects of the sampling schemes on the image quality.Methods: Data properties of several sampling schemes are analyzed with respect to the CS-based image reconstruction using two measures: sampling density and data incoherence. The authors present five different sparse sampling schemes, and simulated those schemes to achieve a targeted dose reduction. Dose reduction factors of about 75% and 87.5%, compared to a conventional scan, were tested. A fully sampled circular cone-beam CT data set was used as a reference, and sparse sampling has been realized numerically based on the CBCT data.Results: It is found that both sampling density and data incoherence affect the image quality in the CS-based reconstruction. Among the sampling schemes the authors investigated, the sparse-view, many-view undersampling (MVUS)-fine, and MVUS-moving cases have shown promising results. These sampling schemes produced images with similar image quality compared to the reference image and their structure similarity index values were higher than 0.92 in the mouse head scan with 75% dose reduction.Conclusions: The authors found that in CS-based image reconstructions both sampling density and data incoherence affect the image quality, and suggest that a sampling scheme should be devised and optimized by use of these indicators. With this strategic

  19. Cell dispensing in low-volume range with the immediate drop-on-demand technology (I-DOT).

    Science.gov (United States)

    Schober, Lena; Büttner, Evy; Laske, Christopher; Traube, Andrea; Brode, Tobias; Traube, Andreas Florian; Bauernhansl, Thomas

    2015-04-01

    Handling and dosing of cells comprise the most critical step in the microfabrication of cell-based assay systems for screening and toxicity testing. Therefore, the immediate drop-on-demand technology (I-DOT) was developed to provide a flexible noncontact liquid handling system enabling dispensing of cells and liquid without the risk of cross-contamination down to a precise volume in the nanoliter range. Liquid is dispensed from a source plate within nozzles at the bottom by a short compressed air pulse that is given through a quick release valve into the well, thus exceeding the capillary pressure in the nozzle. Droplets of a defined volume can be spotted directly onto microplates or other cell culture devices. We present a study on the performance and biological impact of this technology by applying the cell line MCF-7, human fibroblasts, and human mesenchymal stem cells (hMSCs). For all cell types tested, viability after dispensing is comparable to the control and exhibits similar proliferation rates in the absence of apoptotic cells, and the differentiation potential of hMSCs is not impaired. The immediate drop-on-demand technology enables accurate cell dosage and offers promising potential for single-cell applications. © 2014 Society for Laboratory Automation and Screening.

  20. Application of basic pharmacology and dispensing practice of antibiotics in accredited drug-dispensing outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Minzi OM

    2013-01-01

    , antibiotic sale without prescription and no referral made, for complicated cases, ADDOs performed worse than DLDBs. As many as 30% of DLDBs and 35% of ADDOs dispensed incomplete doses of antibiotics. In both ADDOs and DLDBs, fortified procaine penicillin powder was dispensed as topical application for injuries.Conclusion: There was no statistical difference between ADDOs and DLDBs in the violation of dispensing practice and both ADDOs and DLDBs expressed poor knowledge of the basic pharmacology of antibiotics.Keywords: antibiotic-dispensing practice, duka la dawa baridi, accredited drug-dispensing outlets

  1. Using Healthcare Failure Mode and Effect Analysis to reduce medication errors in the process of drug prescription, validation and dispensing in hospitalised patients.

    Science.gov (United States)

    Vélez-Díaz-Pallarés, Manuel; Delgado-Silveira, Eva; Carretero-Accame, María Emilia; Bermejo-Vicedo, Teresa

    2013-01-01

    To identify actions to reduce medication errors in the process of drug prescription, validation and dispensing, and to evaluate the impact of their implementation. A Health Care Failure Mode and Effect Analysis (HFMEA) was supported by a before-and-after medication error study to measure the actual impact on error rate after the implementation of corrective actions in the process of drug prescription, validation and dispensing in wards equipped with computerised physician order entry (CPOE) and unit-dose distribution system (788 beds out of 1080) in a Spanish university hospital. The error study was carried out by two observers who reviewed medication orders on a daily basis to register prescription errors by physicians and validation errors by pharmacists. Drugs dispensed in the unit-dose trolleys were reviewed for dispensing errors. Error rates were expressed as the number of errors for each process divided by the total opportunities for error in that process times 100. A reduction in prescription errors was achieved by providing training for prescribers on CPOE, updating prescription procedures, improving clinical decision support and automating the software connection to the hospital census (relative risk reduction (RRR), 22.0%; 95% CI 12.1% to 31.8%). Validation errors were reduced after optimising time spent in educating pharmacy residents on patient safety, developing standardised validation procedures and improving aspects of the software's database (RRR, 19.4%; 95% CI 2.3% to 36.5%). Two actions reduced dispensing errors: reorganising the process of filling trolleys and drawing up a protocol for drug pharmacy checking before delivery (RRR, 38.5%; 95% CI 14.1% to 62.9%). HFMEA facilitated the identification of actions aimed at reducing medication errors in a healthcare setting, as the implementation of several of these led to a reduction in errors in the process of drug prescription, validation and dispensing.

  2. ASHP national survey of pharmacy practice in hospital settings: dispensing and administration--2011.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2012-05-01

    Results of the 2011 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are presented. A stratified random sample of pharmacy directors at 1401 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 40.1%. Decentralization of the medication-use system continues, with 40% of hospitals using a decentralized system and 58% of hospitals planning to use a decentralized model in the future. Automated dispensing cabinets were used by 89% of hospitals, robots were used by 11%, carousels were used in 18%, and machine-readable coding was used in 34% of hospitals to verify doses before dispensing. Overall, 65% of hospitals had a United States Pharmacopeia chapter 797 compliant cleanroom for compounding sterile preparations. Medication administration records (MARs) have become increasingly computerized, with 67% of hospitals using electronic MARs. Bar-code-assisted medication administration was used in 50% of hospitals, and 68% of hospitals had smart infusion pumps. Health information is becoming more electronic, with 67% of hospitals having partially or completely implemented an electronic health record and 34% of hospitals having computerized prescriber order entry. The use of these technologies has substantially increased over the past year. The average number of full-time equivalent staff per 100 occupied beds averaged 17.5 for pharmacists and 15.0 for technicians. Directors of pharmacy reported declining vacancy rates for pharmacists. Pharmacists continue to improve medication use at the dispensing and administration steps of the medication-use system. The adoption of new technology is changing the philosophy of medication distribution, and health information is rapidly becoming electronic.

  3. ASHP national survey of pharmacy practice in hospital settings: Dispensing and administration--2014.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2015-07-01

    The results of the 2014 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are described. A stratified random sample of pharmacy directors at 1435 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 29.7%. Ninety-seven percent of hospitals used automated dispensing cabinets in their medication distribution systems, 65.7% of which used individually secured lidded pockets as the predominant configuration. Overall, 44.8% of hospitals used some form of machine-readable coding to verify doses before dispensing in the pharmacy. Overall, 65% of hospital pharmacy departments reported having a cleanroom compliant with United States Pharmacopeia chapter 797. Pharmacists reviewed and approved all medication orders before the first dose was administered, either onsite or by remote order view, except in procedure areas and emergency situations, in 81.2% of hospitals. Adoption rates of electronic health information have rapidly increased, with the widespread use of electronic health records, computer prescriber order entry, barcodes, and smart pumps. Overall, 31.4% of hospitals had pharmacists practicing in ambulatory or primary care clinics. Transitions-of-care services offered by the pharmacy department have generally increased since 2012. Discharge prescription services increased from 11.8% of hospitals in 2012 to 21.5% in 2014. Approximately 15% of hospitals outsourced pharmacy management operations to a contract pharmacy services provider, an increase from 8% in 2011. Health-system pharmacists continue to have a positive impact on improving healthcare through programs that improve the efficiency, safety, and clinical outcomes of medication use in health systems. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  4. IoT for Real-Time Measurement of High-Throughput Liquid Dispensing in Laboratory Environments.

    Science.gov (United States)

    Shumate, Justin; Baillargeon, Pierre; Spicer, Timothy P; Scampavia, Louis

    2018-04-01

    Critical to maintaining quality control in high-throughput screening is the need for constant monitoring of liquid-dispensing fidelity. Traditional methods involve operator intervention with gravimetric analysis to monitor the gross accuracy of full plate dispenses, visual verification of contents, or dedicated weigh stations on screening platforms that introduce potential bottlenecks and increase the plate-processing cycle time. We present a unique solution using open-source hardware, software, and 3D printing to automate dispenser accuracy determination by providing real-time dispense weight measurements via a network-connected precision balance. This system uses an Arduino microcontroller to connect a precision balance to a local network. By integrating the precision balance as an Internet of Things (IoT) device, it gains the ability to provide real-time gravimetric summaries of dispensing, generate timely alerts when problems are detected, and capture historical dispensing data for future analysis. All collected data can then be accessed via a web interface for reviewing alerts and dispensing information in real time or remotely for timely intervention of dispense errors. The development of this system also leveraged 3D printing to rapidly prototype sensor brackets, mounting solutions, and component enclosures.

  5. On demand manufacturing of patient-specific liquid capsules via co-ordinated 3D printing and liquid dispensing.

    Science.gov (United States)

    Okwuosa, Tochukwu C; Soares, Cindy; Gollwitzer, Verena; Habashy, Rober; Timmins, Peter; Alhnan, Mohamed A

    2018-06-15

    A method for the production of liquid capsules with the potential of modifying drug dose and release is presented. For the first time, the co-ordinated use of fused deposition modelling (FDM), 3D printing and liquid dispensing to fabricate individualised dosage form on demand in a fully automated fashion has been demonstrated. Polymethacrylate shells (Eudragit EPO and RL) for immediate and extended release were fabricated using FDM 3D printing and simultaneously filled using a computer-controlled liquid dispenser loaded with model drug solution (theophylline) or suspension (dipyridamole). The impact of printing modes: simultaneous shell printing and filling (single-phase) or sequential 3D printing of shell bottom, filling and shell cap (multi-phase), nozzle size, syringe volume, and shell structure has been reported. The use of shell thickness of 1.6 mm, and concentric architecture allowed successful containment of liquid core whilst maintaining the release properties of the 3D printed liquid capsule. The linear relationship between the theoretical and the actual volumes from the dispenser reflected its potential for accurate dosing (R 2  = 0.9985). Modifying the shell thickness of Eudragit RL capsule allowed a controlled extended drug release without the need for formulation change. Owing to its low cost and versatility, this approach can be adapted to wide spectrum of liquid formulations such as small and large molecule solutions and obviate the need for compatibility with the high temperature of FDM 3D printing process. In a clinical setting, health care staff will be able to instantly manufacture in small volumes liquid capsules with individualised dose contents and release pattern in response to specific patient's needs. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Robotic liquid handling and automation in epigenetics.

    Science.gov (United States)

    Gaisford, Wendy

    2012-10-01

    Automated liquid-handling robots and high-throughput screening (HTS) are widely used in the pharmaceutical industry for the screening of large compound libraries, small molecules for activity against disease-relevant target pathways, or proteins. HTS robots capable of low-volume dispensing reduce assay setup times and provide highly accurate and reproducible dispensing, minimizing variation between sample replicates and eliminating the potential for manual error. Low-volume automated nanoliter dispensers ensure accuracy of pipetting within volume ranges that are difficult to achieve manually. In addition, they have the ability to potentially expand the range of screening conditions from often limited amounts of valuable sample, as well as reduce the usage of expensive reagents. The ability to accurately dispense lower volumes provides the potential to achieve a greater amount of information than could be otherwise achieved using manual dispensing technology. With the emergence of the field of epigenetics, an increasing number of drug discovery companies are beginning to screen compound libraries against a range of epigenetic targets. This review discusses the potential for the use of low-volume liquid handling robots, for molecular biological applications such as quantitative PCR and epigenetics.

  7. Analysis of costs to dispense prescriptions in independently owned, closed-door long-term care pharmacies.

    Science.gov (United States)

    Carroll, Norman V; Rupp, Michael T; Holdford, David A

    2014-03-01

    developed to examine the impact of shorter dispensing cycles on LTC pharmacies' CTD. A prescription volume increase of 19% was assumed based on converting only solid oral branded drugs to short-cycle dispensing. A diverse sample of 64 closed-door LTC pharmacies returned usable surveys. Sales from dispensing to LTC facilities accounted for more than 98% of total sales. Respondents indicated that they currently dispensed 23% of total doses in 14-day-or-less cycles and 76% in 28-31 day cycles. Most pharmacies used automated medication packaging technology, heat and cold package sealers, bar code systems, sterile compounding hoods, LTC printers or labelers, and electronic prescribing. The median CTD was $13.54 with an interquartile range (25th to 75th percentiles) of $10.51 to $17.66. More than half of dispensing-related costs were from personnel expense, of which pharmacists and managers accounted for more than 40%. The results of the fixed and variable cost modeling suggested that converting solid oral brand-name drugs from 30-day to 14-day dispensing cycles would lower the median per prescription CTD to between $11.63 and $12.54, depending on the assumptions made about the effects of semivariable costs. However, this decrease in per prescription dispensing cost is dwarfed by an increase in total dispensing cost incurred by pharmacies that results from doubling the monthly volume of short-cycle prescriptions that must be dispensed. The result is that the typical LTC pharmacy in our sample incurred a CTD of $13.54 if the medication is dispensed in a 30-day cycle or $23.26 if the medication is dispensed in two 14-day cycles (at a cost of $11.63 for each cycle dispensed). Our results indicated a median CTD of $13.54 for the typical independently owned, closed-door LTC pharmacy. Moving to a shorter cycle would reduce pharmacies' average per-prescription CTD but would increase the number of prescriptions dispensed per month. Our results indicated that transitioning solid oral

  8. Automated drug dispensing systems in the intensive care unit: a financial analysis.

    Science.gov (United States)

    Chapuis, Claire; Bedouch, Pierrick; Detavernier, Maxime; Durand, Michel; Francony, Gilles; Lavagne, Pierre; Foroni, Luc; Albaladejo, Pierre; Allenet, Benoit; Payen, Jean-Francois

    2015-09-09

    To evaluate the economic impact of automated-drug dispensing systems (ADS) in surgical intensive care units (ICUs). A financial analysis was conducted in three adult ICUs of one university hospital, where ADS were implemented, one in each unit, to replace the traditional floor stock system. Costs were estimated before and after implementation of the ADS on the basis of floor stock inventories, expired drugs, and time spent by nurses and pharmacy technicians on medication-related work activities. A financial analysis was conducted that included operating cash flows, investment cash flows, global cash flow and net present value. After ADS implementation, nurses spent less time on medication-related activities with an average of 14.7 hours saved per day/33 beds. Pharmacy technicians spent more time on floor-stock activities with an average of 3.5 additional hours per day across the three ICUs. The cost of drug storage was reduced by €44,298 and the cost of expired drugs was reduced by €14,772 per year across the three ICUs. Five years after the initial investment, the global cash flow was €148,229 and the net present value of the project was positive by €510,404. The financial modeling of the ADS implementation in three ICUs showed a high return on investment for the hospital. Medication-related costs and nursing time dedicated to medications are reduced with ADS.

  9. [Economic impact of an automated dispensing system in an intensive care unit].

    Science.gov (United States)

    Kheniene, F; Bedouch, P; Durand, M; Marie, F; Brudieu, E; Tourlonnias, M-M; Bongi, P; Allenet, B; Calop, J

    2008-03-01

    Automated dispensing systems (ADS) allow a reduction of medication errors and an improvement of drug distribution in clinical ward. The objective of this study was to evaluate the economic impact of ADS in an intensive care unit. A cost-benefit model was constructed based on the hospital perspective. The system was evaluated before-after implementation of an ADS in a 12-bed cardiovascular intensive care unit of a French teaching hospital: (a) by a measuring nurse and pharmacy technician working time required for various tasks; (b) by measuring the cost of drug storage and the cost of expired drug; (c) by measuring the nurses' acceptability. After ADS was installed, nursing personnel spent less time on medication-related activities (mean of 1.9 hour/day of nursing time). Pharmacy technicians spent more time on floor-stock activities (mean of 0.7 hour/day of technician time). Implementation reduced the cost of drug storage by 56% (14,742 euros) and cost of expired drug by 9,086 euros per year. Finally, cost-benefit analysis including potential savings in terms of working time showed a net benefit of 71,586 euros (14,317 euros/year). The ADS was given high marks by the nurses; 77% wanted to keep it on their unit. Implementation of ADS is expected to generate direct savings for the hospital and working time reallocation, for nurses to interact with patients and for pharmacy technicians to get involved on the ward.

  10. Direct-Dispense Polymeric Waveguides Platform for Optical Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Mohamad Hajj-Hassan

    2008-12-01

    Full Text Available We describe an automated robotic technique called direct-dispense to fabricate a polymeric platform that supports optical sensor arrays. Direct-dispense, which is a type of the emerging direct-write microfabrication techniques, uses fugitive organic inks in combination with cross-linkable polymers to create microfluidic channels and other microstructures. Specifically, we describe an application of direct-dispensing to develop optical biochemical sensors by fabricating planar ridge waveguides that support sol-gelderived xerogel-based thin films. The xerogel-based sensor materials act as host media to house luminophore biochemical recognition elements. As a prototype implementation, we demonstrate gaseous oxygen (O2 responsive optical sensors that operate on the basis of monitoring luminescence intensity signals. The optical sensor employs a Light Emitting Diode (LED excitation source and a standard silicon photodiode as the detector. The sensor operates over the full scale (0%-100% of O2 concentrations with a response time of less than 1 second. This work has implications for the development of miniaturized multisensor platforms that can be cost-effectively and reliably mass-produced.

  11. Smart DNA Fabrication Using Sound Waves: Applying Acoustic Dispensing Technologies to Synthetic Biology.

    Science.gov (United States)

    Kanigowska, Paulina; Shen, Yue; Zheng, Yijing; Rosser, Susan; Cai, Yizhi

    2016-02-01

    Acoustic droplet ejection (ADE) technology uses focused acoustic energy to transfer nanoliter-scale liquid droplets with high precision and accuracy. This noncontact, tipless, low-volume dispensing technology minimizes the possibility of cross-contamination and potentially reduces the costs of reagents and consumables. To date, acoustic dispensers have mainly been used in screening libraries of compounds. In this paper, we describe the first application of this powerful technology to the rapidly developing field of synthetic biology, for DNA synthesis and assembly at the nanoliter scale using a Labcyte Echo 550 acoustic dispenser. We were able to successfully downscale PCRs and the popular one-pot DNA assembly methods, Golden Gate and Gibson assemblies, from the microliter to the nanoliter scale with high assembly efficiency, which effectively cut the reagent cost by 20- to 100-fold. We envision that acoustic dispensing will become an instrumental technology in synthetic biology, in particular in the era of DNA foundries. © 2015 Society for Laboratory Automation and Screening.

  12. An Automated Scheme for the Large-Scale Survey of Herbig-Haro Objects

    Science.gov (United States)

    Deng, Licai; Yang, Ji; Zheng, Zhongyuan; Jiang, Zhaoji

    2001-04-01

    Owing to their spectral properties, Herbig-Haro (HH) objects can be discovered using photometric methods through a combination of filters, sampling the characteristic spectral lines and the nearby continuum. The data are commonly processed through direct visual inspection of the images. To make data reduction more efficient and the results more uniform and complete, an automated searching scheme for HH objects is developed to manipulate the images using IRAF. This approach helps to extract images with only intrinsic HH emissions. By using this scheme, the pointlike stellar sources and extended nebulous sources with continuum emission can be eliminated from the original images. The objects with only characteristic HH emission become prominent and can be easily picked up. In this paper our scheme is illustrated by a sample field and has been applied to our surveys for HH objects.

  13. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  14. Automation systems for radioimmunoassay

    International Nuclear Information System (INIS)

    Yamasaki, Paul

    1974-01-01

    The application of automation systems for radioimmunoassay (RIA) was discussed. Automated systems could be useful in the second step, of the four basic processes in the course of RIA, i.e., preparation of sample for reaction. There were two types of instrumentation, a semi-automatic pipete, and a fully automated pipete station, both providing for fast and accurate dispensing of the reagent or for the diluting of sample with reagent. Illustrations of the instruments were shown. (Mukohata, S.)

  15. Prescription habits of dispensing and non-dispensing doctors in Zimbabwe

    DEFF Research Database (Denmark)

    Trap, Birna; Hansen, Ebba Holme; Hogerzeil, Hans V

    2002-01-01

    , race, place of education, location of practice and patients seen per day showed that dispensing by doctors was associated with less clinically and economically appropriate prescribing. These findings suggest that the quality of health care--as related to drug use, patient safety and treatment cost......The number of dispensing doctors has increased in the last decade, but the implication of this trend on the quality of health care and drug use is unknown. We present a comparative drug utilization study of 29 dispensing doctors and 28 non-dispensing doctors in Zimbabwe based on standard indicators...... developed by the World Health Organization. Dispensing doctors prescribed significantly more drugs per patient than non-dispensing doctors (2.3 versus 1.7), injected more patients (28.4% versus 9.5%), and prescribed more antibiotics (0.72 versus 0.54) and mixtures (0.43 versus 0.25) per encounter...

  16. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Methods: A qualitative study with snowball sampling technique was used to identify fifteen dispensers working in community pharmacies in Islamabad, Peshawar and Lahore. Semi-structured interviews were conducted with the dispensers until the point of saturation was obtained. The interviews which focused on three ...

  17. Impact of multiple-dose versus single-dose inhaler devices on COPD patients’ persistence with long-acting β2-agonists: a dispensing database analysis

    Science.gov (United States)

    van Boven, Job FM; van Raaij, Joost J; van der Galiën, Ruben; Postma, Maarten J; van der Molen, Thys; Dekhuijzen, PN Richard; Vegter, Stefan

    2014-01-01

    Background: With a growing availability of different devices and types of medication, additional evidence is required to assist clinicians in prescribing the optimal medication in relation to chronic obstructive pulmonary disease (COPD) patients’ persistence with long-acting β2-agonists (LABAs). Aims: To assess the impact of the type of inhaler device (multiple-dose versus single-dose inhalers) on 1-year persistence and switching patterns with LABAs. Methods: A retrospective observational cohort study was performed comparing a cohort of patients initiating multiple-dose inhalers and a cohort initiating single-dose inhalers. The study population consisted of long-acting bronchodilator naive COPD patients, initiating inhalation therapy with mono-LABAs (formoterol, indacaterol or salmeterol). Analyses were performed using pharmacy dispensing data from 1994 to 2012, obtained from the IADB.nl database. Study outcomes were 1-year persistence and switching patterns. Results were adjusted for initial prescriber, initial medication, dosing regimen and relevant comorbidities. Results: In all, 575 patients initiating LABAs were included in the final study cohort. Among them, 475 (83%) initiated a multiple-dose inhaler and 100 (17%) a single-dose inhaler. Further, 269 (47%) initiated formoterol, 9 (2%) indacaterol and 297 (52%) salmeterol. There was no significant difference in persistence between users of multiple-dose or single-dose inhalers (hazard ratio: 0.98, 95% confidence interval: 0.76–1.26, P=0.99). Over 80% re-started or switched medication. Conclusions: There seems no impact of inhaler device (multiple-dose versus single-dose inhalers) on COPD patients’ persistence with LABAs. Over 80% of patients who initially seemed to discontinue LABAs, re-started their initial medication or switched inhalers or medication within 1 year. PMID:25274453

  18. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  19. Prescribed 3-D Direct Writing of Suspended Micron/Sub-micron Scale Fiber Structures via a Robotic Dispensing System.

    Science.gov (United States)

    Yuan, Hanwen; Cambron, Scott D; Keynton, Robert S

    2015-06-12

    A 3-axis dispensing system is utilized to control the initiating and terminating fiber positions and trajectory via the dispensing software. The polymer fiber length and orientation is defined by the spatial positioning of the dispensing system 3-axis stages. The fiber diameter is defined by the prescribed dispense time of the dispensing system valve, the feed rate (the speed at which the stage traverses from an initiating to a terminating position), the gauge diameter of the dispensing tip, the viscosity and surface tension of the polymer solution, and the programmed drawing length. The stage feed rate affects the polymer solution's evaporation rate and capillary breakup of the filaments. The dispensing system consists of a pneumatic valve controller, a droplet-dispensing valve and a dispensing tip. Characterization of the direct write process to determine the optimum combination of factors leads to repeatedly acquiring the desired range of fiber diameters. The advantage of this robotic dispensing system is the ease of obtaining a precise range of micron/sub-micron fibers onto a desired, programmed location via automated process control. Here, the discussed self-assembled micron/sub-micron scale 3D structures have been employed to fabricate suspended structures to create micron/sub-micron fluidic devices and bioengineered scaffolds.

  20. A model for automation of radioactive dose control

    International Nuclear Information System (INIS)

    Ribeiro, Carlos Henrique Calazans; Zambon, Jose Waldir; Bitelli, Ricardo; Honaiser, Eduardo Henrique Rangel

    2009-01-01

    The paper presents a proposal for automation of the personnel dose control system to be used in nuclear medicine environments. The model has considered the Standards and rules of the National Commission of Nuclear Energy (CNEN) and of the Health Ministry. The advantages of the model is a robust management of the integrated dose and technicians qualification status. The software platform selected to be used was the Lotus Notes and an analysis of the advantages, disadvantages of the use of this platform is also presented. (author)

  1. A model for automation of radioactive dose control

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Carlos Henrique Calazans; Zambon, Jose Waldir; Bitelli, Ricardo; Honaiser, Eduardo Henrique Rangel [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil)], e-mail: calazans@ctmsp.mar.mil.br, e-mail: zambon@ctmsp.mar.mil.br, e-mail: bitelli@ctmsp.mar.mil.br, e-mail: honaiser@ctmsp.mar.mil.br

    2009-07-01

    The paper presents a proposal for automation of the personnel dose control system to be used in nuclear medicine environments. The model has considered the Standards and rules of the National Commission of Nuclear Energy (CNEN) and of the Health Ministry. The advantages of the model is a robust management of the integrated dose and technicians qualification status. The software platform selected to be used was the Lotus Notes and an analysis of the advantages, disadvantages of the use of this platform is also presented. (author)

  2. Digital Imaging and Piezo-dispenser Actuator in Automatic Flocculation Control

    Directory of Open Access Journals (Sweden)

    Jani TOMPERI

    2012-01-01

    Full Text Available This study presents an image-based on-line control system for a coiled pipe flocculator. A digital imaging technique developed previously is utilized to measure the characteristic floc size and a high-pressure piezo-dispenser is introduced for accurate dosing and rapid mixing of the flocculant. The controller is a conventional PI controller. Step change experiments on feed water quality, flow rate and desired floc size have been carried out for controller tuning and testing. The paper shows that the piezo-dispenser provides better flocculation results than a conventional dosing pump, and the flocculation result can be automatically controlled even when the feed water quality rapidly changes. The proposed flocculator is a simple, inexpensive and practical system for long-term laboratory tests to investigate the functionality of flocculants on varying feed waters.

  3. The impact of an automated dose-dispensing scheme on user compliance, medication understanding, and medication stockpiles

    DEFF Research Database (Denmark)

    Larsen, Anna Bira; Haugbølle, Lotte Stig

    2007-01-01

    the assumed user benefits. Neither Danish nor international studies dealt with users' perspective on ADD in general or with respect to the pinpointed benefits, and thus exploration was needed. OBJECTIVES: The objective of this article is to respond to the following research question: How does ADD affect users......' handling and consumption of medication in terms of compliance behavior, and how does the assumption of user benefits made by health professionals and legislators measure up to users' experiences with ADD? METHODS: The results built on a secondary analysis of 9 qualitative interviews with a varied selection...... understanding, nor does it automatically eliminate stockpiles of old medication in users' homes. The gap between the perspectives of users and health professionals makes a compelling case for considering users' voices in the development and implementation of future health technologies....

  4. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  5. What motivates antibiotic dispensing in accredited drug dispensing outlets in Tanzania? A qualitative study.

    Science.gov (United States)

    Dillip, Angel; Embrey, Martha; Shekalaghe, Elizabeth; Ross-Degnan, Dennis; Vialle-Valentin, Catherine; Kimatta, Suleiman; Liana, Jafary; Rutta, Edmund; Valimba, Richard; Chalker, John

    2015-01-01

    Tanzania introduced the accredited drug dispensing outlet (ADDO) program more than a decade ago. Previous evaluations have generally shown that ADDOs meet defined standards of practice better than non-accredited outlets. However, ADDOs still face challenges with overuse of antibiotics for acute respiratory infections (ARI) and simple diarrhea, which contributes to the emergence of drug resistance. This study aimed to explore the attitudes of ADDO owners and dispensers toward antibiotic dispensing and to learn how accreditation has influenced their dispensing behavior. The study used a qualitative approach. We conducted in-depth interviews with ADDO owners and dispensers in Ruvuma and Tanga regions where the government implemented the ADDO program under centralized and decentralized approaches, respectively; a secondary aim was to compare differences between the two regions. Findings indicate that the ADDO program has brought about positive changes in knowledge of dispensing practices. Respondents were able to correctly explain treatment guidelines for ARI and diarrhea. Almost all dispensers and owners indicated that unnecessary use of antibiotics contributed to antimicrobial resistance. Despite this knowledge, translating it to appropriate dispensing practice is still low. Dispensers' behavior is driven by customer demand, habit ("mazoea"), following inappropriate health facility prescriptions, and the need to make a profit. Although the majority of dispensers reported that they had intervened in situations where customers asked for antibiotics unnecessarily, they tended to give in to clients' requests. Small variations were noted between the two study regions; for example, some dispensers in Ruvuma reported sending clients with incorrect prescriptions back to the health facility, a practice that may reflect regional differences in ADDO implementation and in Integrated Management of Childhood Illness training. Dispensers in rural settings reported more challenges

  6. Automated system for management of cementation line at Kursk NPP

    International Nuclear Information System (INIS)

    Petukhov, K.S.; Troshchenko, V.G.; Osintsev, V.V.; Molotkov, V.P.

    2005-01-01

    At Kursk NPP technological scheme of radioactive wastes tempering by dry cement mixture in continuously working mixer with continuous dosing of cement mixture components is accepted. The automated system designed for control and management of liquid radioactive wastes cementation in real time is represented [ru

  7. Normal tissue complication probabilities: dependence on choice of biological model and dose-volume histogram reduction scheme

    International Nuclear Information System (INIS)

    Moiseenko, Vitali; Battista, Jerry; Van Dyk, Jake

    2000-01-01

    Purpose: To evaluate the impact of dose-volume histogram (DVH) reduction schemes and models of normal tissue complication probability (NTCP) on ranking of radiation treatment plans. Methods and Materials: Data for liver complications in humans and for spinal cord in rats were used to derive input parameters of four different NTCP models. DVH reduction was performed using two schemes: 'effective volume' and 'preferred Lyman'. DVHs for competing treatment plans were derived from a sample DVH by varying dose uniformity in a high dose region so that the obtained cumulative DVHs intersected. Treatment plans were ranked according to the calculated NTCP values. Results: Whenever the preferred Lyman scheme was used to reduce the DVH, competing plans were indistinguishable as long as the mean dose was constant. The effective volume DVH reduction scheme did allow us to distinguish between these competing treatment plans. However, plan ranking depended on the radiobiological model used and its input parameters. Conclusions: Dose escalation will be a significant part of radiation treatment planning using new technologies, such as 3-D conformal radiotherapy and tomotherapy. Such dose escalation will depend on how the dose distributions in organs at risk are interpreted in terms of expected complication probabilities. The present study indicates considerable variability in predicted NTCP values because of the methods used for DVH reduction and radiobiological models and their input parameters. Animal studies and collection of standardized clinical data are needed to ascertain the effects of non-uniform dose distributions and to test the validity of the models currently in use

  8. Effects of a direct refill program for automated dispensing cabinets on medication-refill errors.

    Science.gov (United States)

    Helmons, Pieter J; Dalton, Ashley J; Daniels, Charles E

    2012-10-01

    The effects of a direct refill program for automated dispensing cabinets (ADCs) on medication-refill errors were studied. This study was conducted in designated acute care areas of a 386-bed academic medical center. A wholesaler-to-ADC direct refill program, consisting of prepackaged delivery of medications and bar-code-assisted ADC refilling, was implemented in the inpatient pharmacy of the medical center in September 2009. Medication-refill errors in 26 ADCs from the general medicine units, the infant special care unit, the surgical and burn intensive care units, and intermediate units were assessed before and after the implementation of this program. Medication-refill errors were defined as an ADC pocket containing the wrong drug, wrong strength, or wrong dosage form. ADC refill errors decreased by 77%, from 62 errors per 6829 refilled pockets (0.91%) to 8 errors per 3855 refilled pockets (0.21%) (p error type detected before the intervention was the incorrect medication (wrong drug, wrong strength, or wrong dosage form) in the ADC pocket. Of the 54 incorrect medications found before the intervention, 38 (70%) were loaded in a multiple-drug drawer. After the implementation of the new refill process, 3 of the 5 incorrect medications were loaded in a multiple-drug drawer. There were 3 instances of expired medications before and only 1 expired medication after implementation of the program. A redesign of the ADC refill process using a wholesaler-to-ADC direct refill program that included delivery of prepackaged medication and bar-code-assisted refill significantly decreased the occurrence of ADC refill errors.

  9. Impact of Mobile Dose-Tracking Technology on Medication Distribution at an Academic Medical Center.

    Science.gov (United States)

    Kelm, Matthew; Campbell, Udobi

    2016-05-01

    Medication dose-tracking technologies have the potential to improve efficiency and reduce costs associated with re-dispensing doses reported as missing. Data describing this technology and its impact on the medication use process are limited. The purpose of this study is to assess the impact of dose-tracking technology on pharmacy workload and drug expense at an academic, acute care medical center. Dose-tracking technology was implemented in June 2014. Pre-implementation data were collected from February to April 2014. Post-implementation data were collected from July to September 2014. The primary endpoint was the percent of re-dispensed oral syringe and compounded sterile product (CSP) doses within the pre- and post-implementation periods per 1,000 discharges. Secondary endpoints included pharmaceutical expense generated from re-dispensing doses, labor costs, and staff satisfaction with the medication distribution process. We observed an average 6% decrease in re-dispensing of oral syringe and CSP doses from pre- to post-implementation (15,440 vs 14,547 doses; p = .047). However, when values were adjusted per 1,000 discharges, this trend did not reach statistical significance (p = .074). Pharmaceutical expense generated from re-dispensing doses was significantly reduced from pre- to post-implementation ($834,830 vs $746,466 [savings of $88,364]; p = .047). We estimated that $2,563 worth of technician labor was avoided in re-dispensing missing doses. We also saw significant improvement in staff perception of technology assisting in reducing missing doses (p = .0003), as well as improvement in effectiveness of resolving or minimizing missing doses (p = .01). The use of mobile dose-tracking technology demonstrated meaningful reductions in both the number of doses re-dispensed and cost of pharmaceuticals dispensed.

  10. An automated system for the preparation of Large Size Dried (LSD) Spikes

    International Nuclear Information System (INIS)

    Verbruggen, A.; Bauwens, J.; Jakobsson, U.; Eykens, R.; Wellum, R.; Aregbe, Y.; Van De Steene, N.

    2008-01-01

    Large size dried (LSD) spikes have been produced to fulfill the existing requirement for reliable and traceable isotopic reference materials for nuclear safeguards. A system to produce certified nuclear isotopic reference material as a U/Pu mixture in the form of large size dried spikes, comparable to those produced using traditional methods has been installed in collaboration with Nucomat, a company with a recognized reputation in design and development of integrated automated systems. The major components of the system are a robot, two balances, a dispenser and a drying unit fitted into a glove box. The robot is software driven and designed to control all movements inside the glove-box, to identify unambiguously the penicillin vials with a bar-code reader, to dispense the LSD batch solution into the vials and to weigh the amount dispensed. The system functionality has been evaluated and the performance validated by comparing the results from a series of samples dispensed and weighed by the automated system with the results by manual substitution weighing. After applying the proper correction factors to the data from the automated system balance no significant difference was observed between the two. However, an additional component of uncertainty of 3*10 -4 is introduced in the uncertainty budget for the certified weights provided by the automatic system. (authors)

  11. An automated system for the preparation of Large Size Dried (LSD) Spikes

    Energy Technology Data Exchange (ETDEWEB)

    Verbruggen, A.; Bauwens, J.; Jakobsson, U.; Eykens, R.; Wellum, R.; Aregbe, Y. [European Commission - Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Retieseweg 211, B2440 Geel (Belgium); Van De Steene, N. [Nucomat, Mercatorstraat 206, B9100 Sint Niklaas (Belgium)

    2008-07-01

    Large size dried (LSD) spikes have been produced to fulfill the existing requirement for reliable and traceable isotopic reference materials for nuclear safeguards. A system to produce certified nuclear isotopic reference material as a U/Pu mixture in the form of large size dried spikes, comparable to those produced using traditional methods has been installed in collaboration with Nucomat, a company with a recognized reputation in design and development of integrated automated systems. The major components of the system are a robot, two balances, a dispenser and a drying unit fitted into a glove box. The robot is software driven and designed to control all movements inside the glove-box, to identify unambiguously the penicillin vials with a bar-code reader, to dispense the LSD batch solution into the vials and to weigh the amount dispensed. The system functionality has been evaluated and the performance validated by comparing the results from a series of samples dispensed and weighed by the automated system with the results by manual substitution weighing. After applying the proper correction factors to the data from the automated system balance no significant difference was observed between the two. However, an additional component of uncertainty of 3*10{sup -4} is introduced in the uncertainty budget for the certified weights provided by the automatic system. (authors)

  12. [Monitoring medication errors in personalised dispensing using the Sentinel Surveillance System method].

    Science.gov (United States)

    Pérez-Cebrián, M; Font-Noguera, I; Doménech-Moral, L; Bosó-Ribelles, V; Romero-Boyero, P; Poveda-Andrés, J L

    2011-01-01

    To assess the efficacy of a new quality control strategy based on daily randomised sampling and monitoring a Sentinel Surveillance System (SSS) medication cart, in order to identify medication errors and their origin at different levels of the process. Prospective quality control study with one year follow-up. A SSS medication cart was randomly selected once a week and double-checked before dispensing medication. Medication errors were recorded before it was taken to the relevant hospital ward. Information concerning complaints after receiving medication and 24-hour monitoring were also noted. Type and origin error data were assessed by a Unit Dose Quality Control Group, which proposed relevant improvement measures. Thirty-four SSS carts were assessed, including 5130 medication lines and 9952 dispensed doses, corresponding to 753 patients. Ninety erroneous lines (1.8%) and 142 mistaken doses (1.4%) were identified at the Pharmacy Department. The most frequent error was dose duplication (38%) and its main cause inappropriate management and forgetfulness (69%). Fifty medication complaints (6.6% of patients) were mainly due to new treatment at admission (52%), and 41 (0.8% of all medication lines), did not completely match the prescription (0.6% lines) as recorded by the Pharmacy Department. Thirty-seven (4.9% of patients) medication complaints due to changes at admission and 32 matching errors (0.6% medication lines) were recorded. The main cause also was inappropriate management and forgetfulness (24%). The simultaneous recording of incidences due to complaints and new medication coincided in 33.3%. In addition, 433 (4.3%) of dispensed doses were returned to the Pharmacy Department. After the Unit Dose Quality Control Group conducted their feedback analysis, 64 improvement measures for Pharmacy Department nurses, 37 for pharmacists, and 24 for the hospital ward were introduced. The SSS programme has proven to be useful as a quality control strategy to identify Unit

  13. Sample preparation automation for dosing plutonium in urine

    International Nuclear Information System (INIS)

    Jeanmaire, Lucien; Ballada, Jean; Ridelle Berger, Ariane

    1969-06-01

    After having indicated that dosing urinary plutonium by using the Henry technique can be divided into three stages (plutonium concentration by precipitation, passing the solution on an anionic resin column and plutonium elution, and eluate evaporation to obtain a source of which the radioactivity is measured), and recalled that the automation of the second stage has been reported in another document, this document describes the automation of the first stage, i.e. obtaining from urine a residue containing the plutonium, and sufficiently mineralized to be analyzed by means of ion exchanging resins. Two techniques are proposed, leading to slightly different devices. The different operations to be performed are indicated. The different components of the apparatus are described: beakers, hot plate stirrers, reagent circuits, a system for supernatant suction, and a control-command circuit. The operation and use are then described, and results are given

  14. Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation.

    Science.gov (United States)

    Shirley, Ben; Li, Yanxin; Knoll, Joan H M; Rogan, Peter K

    2017-09-04

    Biological radiation dose can be estimated from dicentric chromosome frequencies in metaphase cells. Performing these cytogenetic dicentric chromosome assays is traditionally a manual, labor-intensive process not well suited to handle the volume of samples which may require examination in the wake of a mass casualty event. Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates this process by examining sets of metaphase images using machine learning-based image processing techniques. The software selects appropriate images for analysis by removing unsuitable images, classifies each object as either a centromere-containing chromosome or non-chromosome, further distinguishes chromosomes as monocentric chromosomes (MCs) or dicentric chromosomes (DCs), determines DC frequency within a sample, and estimates biological radiation dose by comparing sample DC frequency with calibration curves computed using calibration samples. This protocol describes the usage of ADCI software. Typically, both calibration (known dose) and test (unknown dose) sets of metaphase images are imported to perform accurate dose estimation. Optimal images for analysis can be found automatically using preset image filters or can also be filtered through manual inspection. The software processes images within each sample and DC frequencies are computed at different levels of stringency for calling DCs, using a machine learning approach. Linear-quadratic calibration curves are generated based on DC frequencies in calibration samples exposed to known physical doses. Doses of test samples exposed to uncertain radiation levels are estimated from their DC frequencies using these calibration curves. Reports can be generated upon request and provide summary of results of one or more samples, of one or more calibration curves, or of dose estimation.

  15. Evaluating the Impact of Drug Dispensing Systems on the Safety and Efficiency in a Singapore Outpatient Pharmacy

    Directory of Open Access Journals (Sweden)

    Peter Ong Yong Sheng

    2014-01-01

    Full Text Available Purpose: Automation of pharmacy workflow can reduce medication errors as well as improve efficiency of the medication picking, packing and labeling process. Since September 2012, two drug dispensing systems (DDS began operations in the Singapore General Hospital Specialist Outpatient Clinic Pharmacy. This study sought to evaluate the impact of the DDS on safety and efficiency in the pharmacy. Methods: The primary outcome was the rate of prevented dispensing incidents contributed by DDS or manual picking of medications defined as the number of prevented dispensing incidents per 1000 medications picked. The secondary outcome was the productivity of each full time equivalent (FTE when assigned to either the DDS or manual picking stations. Data pertaining to the primary and secondary outcomes between January and December 2013 were collected and analyzed. The rate of prevented dispensing incidents was expressed in median (interquartile range and compared using Mann-Whitney U test. Other continuous variables were expressed in mean ± standard deviation and compared using independent samples t-test. Results: An average of 59494 medications was picked every month in the pharmacy. DDS accounted for 21.1 percent while manual picking accounted for 78.9 percent of all the medications picked. The median rate of prevented dispensing incidents per month committed by manual picking (2.73 was significantly higher than the DDS (0.00. DDS had greater productivity with each FTE in the DDS having an average of 6175 picks per month which was significantly higher than each FTE in the manual picking stations which had an average of 4867 picks per month. Conclusion: Installation of DDS in an outpatient pharmacy improved safety of the pharmacy workflow by automating the medication picking, packing and labeling process and minimizing human errors. Efficiency of the medication picking, packing and labeling process was also improved by the DDS as there were continuous

  16. The NRPB automated thermoluminescent dosemeter and dose record keeping system

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1975-03-01

    This report describes the thermoluminescent personal radiation dosemeter and its associated automated processing equipment, which are being developed by the National Radiological Protection Board, together with the operation of a computerised dosemeter issue and record keeping system. The main justifications for introducing these systems are improvements in the organizational efficiency of the maintenance of individual dose records, a more flexible and accurate dosimetry system, and economics in operational costs. The dosemeter is based on a numbered aluminium plate containing two lithium fluoride in polytetrafluorethylene disks for the measurement of surface and body dose. This dosemeter is wrapped in thin plastic and labelled with the wearer's name and address. On return, the dosemeter is checked automatically for radioactive contamination; it is unwrapped and evaluated; the dose readings are included in the wearer's stored dose record; the dosemeter is annealed and is then available for re-issue to another wearer. Dose reports and warnings are automatically issued to the wearer or his employer. (author)

  17. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Erah

    1School of Pharmaceutical Sciences, University Sains Malaysia, 11800 Penang, Malaysia, 2Department of Social ... working in community pharmacies in Islamabad, Peshawar and Lahore. ..... situation regarding dispensing practices in the.

  18. Improving Quality and Occupational Safety on Automated Casting Lines

    Directory of Open Access Journals (Sweden)

    Kukla S.

    2017-09-01

    Full Text Available The paper presents a practical example of improving quality and occupational safety on automated casting lines. Working conditions on the line of box moulding with horizontal mould split were analysed due to low degree of automation at the stage of cores or filters installation as well as spheroidizing mortar dosing. A simulation analysis was carried out, which was related to the grounds of introducing an automatic mortar dispenser to the mould. To carry out the research, a simulation model of a line in universal Arena software for modelling and simulation of manufacturing systems by Rockwell Software Inc. was created. A simulation experiment was carried out on a model in order to determine basic parameters of the working system. Organization and working conditions in other sections of the line were also analysed, paying particular attention to quality, ergonomics and occupational safety. Ergonomics analysis was carried out on manual cores installation workplace and filters installation workplace, and changes to these workplaces were suggested in order to eliminate actions being unnecessary and onerous for employees.

  19. Implementation and development of an automated, ultra-high-capacity, acoustic, flexible dispensing platform for assay-ready plate delivery.

    Science.gov (United States)

    Griffith, Dylan; Northwood, Roger; Owen, Paul; Simkiss, Ellen; Brierley, Andrew; Cross, Kevin; Slaney, Andrew; Davis, Miranda; Bath, Colin

    2012-10-01

    Compound management faces the daily challenge of providing high-quality samples to drug discovery. The advent of new screening technologies has seen demand for liquid samples move toward nanoliter ranges, dispensed by contactless acoustic droplet ejection. Within AstraZeneca, a totally integrated assay-ready plate production platform has been created to fully exploit the advantages of this technology. This enables compound management to efficiently deliver large throughputs demanded by high-throughput screening while maintaining regular delivery of smaller numbers of compounds in varying plate formats for cellular or biochemical concentration-response curves in support of hit and lead optimization (structure-activity relationship screening). The automation solution, CODA, has the capability to deliver compounds on demand for single- and multiple-concentration ranges, in batch sizes ranging from 1 sample to 2 million samples, integrating seamlessly into local compound and test management systems. The software handles compound orders intelligently, grouping test requests together dependent on output plate type and serial dilution ranges so that source compound vessels are shared among numerous tests, ensuring conservation of sample, reduced labware and costs, and efficiency of work cell logistics. We describe the development of CODA to address the customer demand, challenges experienced, learning made, and subsequent enhancements.

  20. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Methods: A qualitative study with snowball sampling technique was used to ... Semi-structured interviews were conducted with the dispensers until the ... and suggestions for improvements were audio-taped, transcribed verbatim and analyzed.

  1. Extraction of CT dose information from DICOM metadata: automated Matlab-based approach.

    Science.gov (United States)

    Dave, Jaydev K; Gingold, Eric L

    2013-01-01

    The purpose of this study was to extract exposure parameters and dose-relevant indexes of CT examinations from information embedded in DICOM metadata. DICOM dose report files were identified and retrieved from a PACS. An automated software program was used to extract from these files information from the structured elements in the DICOM metadata relevant to exposure. Extracting information from DICOM metadata eliminated potential errors inherent in techniques based on optical character recognition, yielding 100% accuracy.

  2. 21 CFR 888.4200 - Cement dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  3. Prescription, dispensation and marketing patterns of methylphenidate

    Directory of Open Access Journals (Sweden)

    Edson Perini

    2014-12-01

    Full Text Available OBJECTIVE To analyze the patterns and legal requirements of methylphenidate consumption. METHODS We conducted a cross-sectional study of the data from prescription notification forms and balance lists of drugs sales – psychoactive and others – subject to special control in the fifth largest city of Brazil, in 2006. We determined the defined and prescribed daily doses, the average prescription and dispensation periods, and the regional sales distribution in the municipality. In addition, we estimated the costs of drug acquisition and analyzed the individual drug consumption profile using the Lorenz curve. RESULTS The balance lists data covered all notified sales of the drug while data from prescription notification forms covered 50.6% of the pharmacies that sold it, including those with the highest sales volumes. Total methylphenidate consumption was 0.37 DDD/1,000 inhabitants/day. Sales were concentrated in more developed areas, and regular-release tablets were the most commonly prescribed pharmaceutical formulation. In some regions of the city, approximately 20.0% of the prescriptions and dispensation exceeded 30 mg/day and 30 days of treatment. CONCLUSIONS Methylphenidate was widely consumed in the municipality and mainly in the most developed areas. Of note, the consumption of formulations with the higher abuse risk was the most predominant. Both its prescription and dispensation contrasted with current pharmacotherapeutic recommendations and legal requirements. Therefore, the commercialization of methylphenidate should be monitored more closely, and its use in the treatment of behavioral changes of psychological disorders needs to be discussed in detail, in line with the concepts of the quality use of medicines.

  4. Dissolvable microneedle fabrication using piezoelectric dispensing technology.

    Science.gov (United States)

    Allen, Evin A; O'Mahony, Conor; Cronin, Michael; O'Mahony, Thomas; Moore, Anne C; Crean, Abina M

    2016-03-16

    Dissolvable microneedle (DMN) patches are novel dosage forms for the percutaneous delivery of vaccines. DMN are routinely fabricated by dispensing liquid formulations into microneedle-shaped moulds. The liquid formulation within the mould is then dried to create dissolvable vaccine-loaded microneedles. The precision of the dispensing process is critical to the control of formulation volume loaded into each dissolvable microneedle structure. The dispensing process employed must maintain vaccine integrity. Wetting of mould surfaces by the dispensed formulation is also an important consideration for the fabrication of sharp-tipped DMN. Sharp-tipped DMN are essential for ease of percutaneous administration. In this paper, we demonstrate the ability of a piezoelectric dispensing system to dispense picolitre formulation volumes into PDMS moulds enabling the fabrication of bilayer DMN. The influence of formulation components (trehalose and polyvinyl alcohol (PVA) content) and piezoelectric actuation parameters (voltage, frequency and back pressure) on drop formation is described. The biological integrity of a seasonal influenza vaccine following dispensing was investigated and maintained voltage settings of 30 V but undermined at higher settings, 50 and 80 V. The results demonstrate the capability of piezoelectric dispensing technology to precisely fabricate bilayer DMN. They also highlight the importance of identifying formulation and actuation parameters to ensure controlled droplet formulation and vaccine stabilisation. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Numerical simulation of a TLD pulsed laser-heating scheme for determination of shallow dose and deep dose in low-LET radiation fields

    International Nuclear Information System (INIS)

    Kearfott, K.J.; Han, S.; Wagner, E.C.; Samei, E.; Wang, C.-K.C.

    2000-01-01

    A new method is described to determine the depth-dose distribution in low-LET radiation fields using a thick thermoluminescent dosimeter (TLD) with a pulsed laser-heating scheme to obtain TL glow output. The computational simulation entails heat conduction and glow curve production processes. An iterative algorithm is used to obtain the dose distribution in the detector. The simulation results indicate that the method can predict the shallow and deep dose in various radiation fields with relative errors less than 20%

  6. Path Searching Based Fault Automated Recovery Scheme for Distribution Grid with DG

    Science.gov (United States)

    Xia, Lin; Qun, Wang; Hui, Xue; Simeng, Zhu

    2016-12-01

    Applying the method of path searching based on distribution network topology in setting software has a good effect, and the path searching method containing DG power source is also applicable to the automatic generation and division of planned islands after the fault. This paper applies path searching algorithm in the automatic division of planned islands after faults: starting from the switch of fault isolation, ending in each power source, and according to the line load that the searching path traverses and the load integrated by important optimized searching path, forming optimized division scheme of planned islands that uses each DG as power source and is balanced to local important load. Finally, COBASE software and distribution network automation software applied are used to illustrate the effectiveness of the realization of such automatic restoration program.

  7. Comparative trials in registration files of cardiovascular drugs : Comparator drugs and dosing schemes.

    NARCIS (Netherlands)

    Wieringa, NF; Vos, R; de Graeff, PA

    Registration files of 13 cardiovascular drugs were analysed with respect to the number of double-blind phase-III clinical trials, the use of placebo and active comparator drugs and their dosing schemes. Half of the 146 double-blind trials used active comparator drugs. The majority of files included

  8. Steam sterilization and automatic dispensing of [18F]fludeoxyglucose (FDG) for injection

    International Nuclear Information System (INIS)

    Karwath, Pascal; Sartor, Johannes; Gries, Wolfgang; Wodarski, Christine; Dittmar, Claus; Biersack, Hans J.; Guhlke, Stefan

    2005-01-01

    For the purpose of implementing steam sterilization of 2-[ 18 F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity (∼99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories

  9. Automated computerized scheme for distinction between benign and malignant solitary pulmonary nodules on chest images

    International Nuclear Information System (INIS)

    Aoyama, Masahito; Li Qiang; Katsuragawa, Shigehiko; MacMahon, Heber; Doi, Kunio

    2002-01-01

    A novel automated computerized scheme has been developed to assist radiologists for their distinction between benign and malignant solitary pulmonary nodules on chest images. Our database consisted of 55 chest radiographs (33 primary lung cancers and 22 benign nodules). In this method, the location of a nodule was indicated first by a radiologist. The difference image with a nodule was produced by use of filters and then represented in a polar coordinate system. The nodule was segmented automatically by analysis of contour lines of the gray-level distribution based on the polar-coordinate representation. Two clinical parameters (age and sex) and 75 image features were determined from the outline, the image, and histogram analysis for inside and outside regions of the segmented nodule. Linear discriminant analysis (LDA) and knowledge about benign and malignant nodules were used to select initial feature combinations. Many combinations for subgroups of 77 features were evaluated as input to artificial neural networks (ANNs). The performance of ANNs with the selected 7 features by use of the round-robin test showed Az=0.872, which was greater than Az=0.854 obtained previously with the manual method (P=0.53). The performance of LDA (Az=0.886) was slightly improved compared to that of ANNs (P=0.59) and was greater than that of the manual method (Az=0.854) reported previously (P=0.40). The high level of its performance indicates the potential usefulness of this automated computerized scheme in assisting radiologists as a second opinion for distinction between benign and malignant solitary pulmonary nodules on chest images

  10. A fully-automated multiscale kernel graph cuts based particle localization scheme for temporal focusing two-photon microscopy

    Science.gov (United States)

    Huang, Xia; Li, Chunqiang; Xiao, Chuan; Sun, Wenqing; Qian, Wei

    2017-03-01

    The temporal focusing two-photon microscope (TFM) is developed to perform depth resolved wide field fluorescence imaging by capturing frames sequentially. However, due to strong nonignorable noises and diffraction rings surrounding particles, further researches are extremely formidable without a precise particle localization technique. In this paper, we developed a fully-automated scheme to locate particles positions with high noise tolerance. Our scheme includes the following procedures: noise reduction using a hybrid Kalman filter method, particle segmentation based on a multiscale kernel graph cuts global and local segmentation algorithm, and a kinematic estimation based particle tracking method. Both isolated and partial-overlapped particles can be accurately identified with removal of unrelated pixels. Based on our quantitative analysis, 96.22% isolated particles and 84.19% partial-overlapped particles were successfully detected.

  11. Estimating the real world daily usage and cost for exenatide twice daily and liraglutide in Germany, the Netherlands, and the UK based on volumes dispensed by pharmacies

    Directory of Open Access Journals (Sweden)

    McDonell AL

    2015-01-01

    Full Text Available Amanda L McDonell,1 Urpo Kiiskinen,2 Danielle C Zammit,3 Robert W Kotchie,1 Per-Olof Thuresson,3 Claudia Nicolay,4 Thomas Haslam,1 Michiel Bruinsma,5 Anne-Jeanine Janszen-Van Oosterhout,6 Thorsten Otto41IMS Health, London, UK; 2Eli Lilly and Company, Helsinki, Finland; 3IMS Health, Basel, Switzerland; 4Eli Lilly and Company, Bad Homburg, Germany; 5IMS Health, Rotterdam, the Netherlands; 6Eli Lilly Nederland, Houten, the NetherlandsBackground: Glucagon-like peptide-1 (GLP-1 receptor agonists are indicated for improvement of glycemic control in adults with type 2 diabetes. Cost is one aspect of treatment to be considered, in addition to clinical benefits, when selecting optimal therapy for a patient. The objective of this study was to estimate the average dose usage and real world daily cost of the GLP-1 receptor agonists, exenatide twice daily and liraglutide once daily, in Germany, the Netherlands, and the UK.Methods: Administrative databases were used to source the data from longitudinal records of dispensed prescriptions. Data were extracted from the IMS Longitudinal Prescription database which captures details of prescriptions dispensed in pharmacies. Information on the dispensed quantity of each product was used to estimate average daily usage per patient. Daily dose usage was multiplied by the public price per unit to estimate daily cost.Results: The dispensed volume in Germany corresponded to a mean dispensed daily dose of 16.81 µg for exenatide twice daily and 1.37 mg for liraglutide (mean daily cost €4.02 and €4.54, respectively. In the Netherlands, average dispensed daily doses of 17.07 µg and 1.49 mg were observed for exenatide twice daily and liraglutide (mean daily cost €3.05 and €3.97, respectively. In the UK, the mean dispensed volume corresponded to a daily usage of 20.49 µg for exenatide twice daily and 1.50 mg for liraglutide (mean daily cost £2.53 and £3.28, respectively.Conclusion: Estimates of average daily

  12. Automating and estimating glomerular filtration rate for dosing medications and staging chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Trinkley KE

    2014-05-01

    Full Text Available Katy E Trinkley,1 S Michelle Nikels,2 Robert L Page II,1 Melanie S Joy11Skaggs School of Pharmacy and Pharmaceutical Sciences, 2School of Medicine, University of Colorado, Aurora, CO, USA Objective: The purpose of this paper is to serve as a review for primary care providers on the bedside methods for estimating glomerular filtration rate (GFR for dosing and chronic kidney disease (CKD staging and to discuss how automated health information technologies (HIT can enhance clinical documentation of staging and reduce medication errors in patients with CKD.Methods: A nonsystematic search of PubMed (through March 2013 was conducted to determine the optimal approach to estimate GFR for dosing and CKD staging and to identify examples of how automated HITs can improve health outcomes in patients with CKD. Papers known to the authors were included, as were scientific statements. Articles were chosen based on the judgment of the authors.Results: Drug-dosing decisions should be based on the method used in the published studies and package labeling that have been determined to be safe, which is most often the Cockcroft–Gault formula unadjusted for body weight. Although Modification of Diet in Renal Disease is more commonly used in practice for staging, the CKD–Epidemiology Collaboration (CKD–EPI equation is the most accurate formula for estimating the CKD staging, especially at higher GFR values. Automated HITs offer a solution to the complexity of determining which equation to use for a given clinical scenario. HITs can educate providers on which formula to use and how to apply the formula in a given clinical situation, ultimately improving appropriate medication and medical management in CKD patients.Conclusion: Appropriate estimation of GFR is key to optimal health outcomes. HITs assist clinicians in both choosing the most appropriate GFR estimation formula and in applying the results of the GFR estimation in practice. Key limitations of the

  13. Evaluation and remediation of bulk soap dispensers for biofilm.

    Science.gov (United States)

    Lorenz, Lindsey A; Ramsay, Bradley D; Goeres, Darla M; Fields, Matthew W; Zapka, Carrie A; Macinga, David R

    2012-01-01

    Recent studies evaluating bulk soap in public restroom soap dispensers have demonstrated up to 25% of open refillable bulk-soap dispensers were contaminated with ~ 6 log(10)(CFU ml(-1)) heterotrophic bacteria. In this study, plastic counter-mounted, plastic wall-mounted and stainless steel wall-mounted dispensers were analyzed for suspended and biofilm bacteria using total cell and viable plate counts. Independent of dispenser type or construction material, the bulk soap was contaminated with 4-7 log(10)(CFU ml(-1)) bacteria, while 4-6 log(10)(CFU cm(-2)) biofilm bacteria were isolated from the inside surfaces of the dispensers (n = 6). Dispenser remediation studies, including a 10 min soak with 5000 mg l(-1) sodium hypochlorite, were then conducted to determine the efficacy of cleaning and disinfectant procedures against established biofilms. The testing showed that contamination of the bulk soap returned to pre-test levels within 7-14 days. These results demonstrate biofilm is present in contaminated bulk-soap dispensers and remediation studies to clean and sanitize the dispensers are temporary.

  14. A Simulated Learning Environment for Teaching Medicine Dispensing Skills.

    Science.gov (United States)

    McDowell, Jenny; Styles, Kim; Sewell, Keith; Trinder, Peta; Marriott, Jennifer; Maher, Sheryl; Naidu, Som

    2016-02-25

    To develop an authentic simulation of the professional practice dispensary context for students to develop their dispensing skills in a risk-free environment. A development team used an Agile software development method to create MyDispense, a web-based simulation. Modeled on virtual learning environments elements, the software employed widely available standards-based technologies to create a virtual community pharmacy environment. Assessment. First-year pharmacy students who used the software in their tutorials, were, at the end of the second semester, surveyed on their prior dispensing experience and their perceptions of MyDispense as a tool to learn dispensing skills. The dispensary simulation is an effective tool for helping students develop dispensing competency and knowledge in a safe environment.

  15. Steam sterilization and automatic dispensing of [{sup 18}F]fludeoxyglucose (FDG) for injection

    Energy Technology Data Exchange (ETDEWEB)

    Karwath, Pascal [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany); Sartor, Johannes [MC-Pharma GmbH (MCP), Bonn (Germany); Gries, Wolfgang [MC-Pharma GmbH (MCP), Bonn (Germany); Wodarski, Christine [MC-Pharma GmbH (MCP), Bonn (Germany); Dittmar, Claus [MC-Pharma GmbH (MCP), Bonn (Germany); Biersack, Hans J [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Guhlke, Stefan [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany)

    2005-04-01

    For the purpose of implementing steam sterilization of 2-[{sup 18}F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity ({approx}99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories.

  16. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  17. A Study on the Scheme for Expanding Automation of a Large-Scale Sewage-End Disposal Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byeong Kuk [Korea Environment Institute, Seoul (Korea)

    2000-12-01

    In Korea, 150 sewage-end disposal plants has been operating on the basis of the end of 1999 year, the number of which will increase to 350. As the emission standard of the nutrition bases like Nitrogen and Phosphorus is enhanced afterward, new demand to dispose them will be created and the higher technology of sewage disposal will be required. Sewage disposal plant also has been making many-sided efforts, enhancing the productivity and curtailing the employees to secure the competitiveness and making most disposing process automatic and unmanned. It is generally considered the curtailment of employees followed after automation, but actually, working burdens of operators has been increasing due to the curtailment of employees before the automation. The utilization of the equipment related to automation has been increasing to reduce the working burdens and heighten the disposal technology, but the survey on the actual condition is insufficient in Korea. Therefore, this study examines the actual condition of automatic equipment based on the domestic large-scale sewage disposal plants, compares it to the foreign technology trends, and suggests the schemes to enhance the utilization of automatic equipment in the sewage disposal plants. The history of the domestic sewage disposal equipment is not long, and the recognition on the necessity of automation is not good. Hence, the domestic data of the research and the basic condition are very scarce. Anyhow, we hope that this study will the starting point to enhance the utilization of automatic equipment for the efficient operation of sewage disposal equipment in future. 14 refs., 10 figs., 16 tabs.

  18. Errors detected in pediatric oral liquid medication doses prepared in an automated workflow management system.

    Science.gov (United States)

    Bledsoe, Sarah; Van Buskirk, Alex; Falconer, R James; Hollon, Andrew; Hoebing, Wendy; Jokic, Sladan

    2018-02-01

    The effectiveness of barcode-assisted medication preparation (BCMP) technology on detecting oral liquid dose preparation errors. From June 1, 2013, through May 31, 2014, a total of 178,344 oral doses were processed at Children's Mercy, a 301-bed pediatric hospital, through an automated workflow management system. Doses containing errors detected by the system's barcode scanning system or classified as rejected by the pharmacist were further reviewed. Errors intercepted by the barcode-scanning system were classified as (1) expired product, (2) incorrect drug, (3) incorrect concentration, and (4) technological error. Pharmacist-rejected doses were categorized into 6 categories based on the root cause of the preparation error: (1) expired product, (2) incorrect concentration, (3) incorrect drug, (4) incorrect volume, (5) preparation error, and (6) other. Of the 178,344 doses examined, 3,812 (2.1%) errors were detected by either the barcode-assisted scanning system (1.8%, n = 3,291) or a pharmacist (0.3%, n = 521). The 3,291 errors prevented by the barcode-assisted system were classified most commonly as technological error and incorrect drug, followed by incorrect concentration and expired product. Errors detected by pharmacists were also analyzed. These 521 errors were most often classified as incorrect volume, preparation error, expired product, other, incorrect drug, and incorrect concentration. BCMP technology detected errors in 1.8% of pediatric oral liquid medication doses prepared in an automated workflow management system, with errors being most commonly attributed to technological problems or incorrect drugs. Pharmacists rejected an additional 0.3% of studied doses. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  19. Systems automated reporting of patient dose in digital radiology; Sistema automatizado para generacion de informes de dosis a paciente en radiologia digital

    Energy Technology Data Exchange (ETDEWEB)

    Collado Chamorro, P.; Sanz Freire, C. J.; Martinez Mirallas, O.; Tejada San Juan, S.; Lopez de Gammarra, M. S.

    2013-07-01

    It has developed a procedure automated reporting of doses to patients in Radiology. This procedure allows to save the time required of the data used to calculate the dose to patients by yields. Also saves the time spent in the transcription of these data for the realization of the necessary calculations. This system has been developed using open source software. The characteristics of the systems of digital radiography for the automation of procedures, in particular the registration of dose should benefit from patient. This procedure is validated and currently in use at our institution. (Author)

  20. The impact of closed-loop electronic medication management on time to first dose: a comparative study between paper and digital hospital environments.

    Science.gov (United States)

    Austin, Jodie A; Smith, Ian R; Tariq, Amina

    2018-01-22

    Closed-loop electronic medication management systems (EMMS) are recognised as an effective intervention to improve medication safety, yet evidence of their effectiveness in hospitals is limited. Few studies have compared medication turnaround time for a closed-loop electronic versus paper-based medication management environment. To compare medication turnaround times in a paper-based hospital environment with a digital hospital equipped with a closed-loop EMMS, consisting of computerised physician order entry, profiled automated dispensing cabinets packaged with unit dose medications and barcode medication administration. Data were collected during 2 weeks at three private hospital sites (one with closed-loop EMMS) within the same organisation network in Queensland, Australia. Time between scheduled and actual administration times was analysed for first dose of time-critical and non-critical medications located on the ward or sourced via pharmacy. Medication turnaround times at the EMMS site were less compared to the paper-based sites (median, IQR: 35 min, 8-57 min versus 120 min, 30-180 min, P medications, 77% were administered within 60 min of scheduled time at the EMMS site versus 38% for the paper-based sites. Similar difference was observed for non-critical medications, 80% were administered within 60 min of their scheduled time at the EMMS site versus 41% at the paper-based facilities. The study indicates medication turnaround times utilising a closed-loop EMMS are less compared to paper-based systems. This improvement may be attributable to increased accessibility of medications using automated dispensing cabinets and electronic medication administration records flagging tasks to nurses in real time. © 2018 Royal Pharmaceutical Society.

  1. A “dose on demand” Biomarker Generator for automated production of [18F]F− and [18F]FDG

    International Nuclear Information System (INIS)

    Awasthi, V.; Watson, J.; Gali, H.; Matlock, G.; McFarland, A.; Bailey, J.; Anzellotti, A.

    2014-01-01

    The University of Oklahoma—College of Pharmacy has installed the first Biomarker Generator (BG75) comprising a self-shielded 7.5-MeV proton beam positive ion cyclotron and an aseptic automated chemistry production and quality control module for production of [ 18 F]F − and clinical [ 18 F]FDG. Performance, reliability, and safety of the system for the production of “dose on demand” were tested over several months. No-carrier-added [ 18 F]F − was obtained through the 18 O(p,n) 18 F nuclear reaction by irradiation (20–40 min) of a >95% enriched [ 18 O]H 2 O target (280 μl) with a 7.5-MeV proton beam (3.5–5.0 μA). Automated quality control tests were performed on each dose. The HPLC-based analytical methods were validated against USP methods of quality control. [ 18 F]FDG produced by BG75 was tested in a mouse tumor model implanted with H441 human lung adenocarcinoma cells. After initial installment and optimization, the [ 18 F]F − production has been consistent since March 2011 with a maximum production of 400 to 450 mCi in a day. The average yield is 0.61 mCi/min and 0.92 mCi/min at 3.8 µA and 5 µA, respectively. The current target window has held up for over 25 weeks against >400 bombardment cycles. [ 18 F]FDG production has been consistent since June 2012 with an average of six doses/day in an automated synthesis mode (RCY≈50%). The release criteria included USP-specified limits for pH, residual solvents (acetonitrile/ethanol), kryptofix, radiochemical purity/identity, and filter integrity test. The entire automated operation generated minimal radiation exposure hazard to the operator and environment. As expected, [ 18 F]FDG produced by BG75 was found to delineate tumor volume in a mouse model of xenograft tumor. In summary, production and quality control of “[ 18 F]FDG dose on demand” have been accomplished in an automated and safe manner by the first Biomarker Generator. The implementation of a cGMP quality system is under way towards

  2. Automated spike preparation system for Isotope Dilution Mass Spectrometry (IDMS)

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Clark, J.P.

    1990-01-01

    Isotope Dilution Mass Spectrometry (IDMS) is a method frequently employed to measure dissolved, irradiated nuclear materials. A known quantity of a unique isotope of the element to be measured (referred to as the ''spike'') is added to the solution containing the analyte. The resulting solution is chemically purified then analyzed by mass spectrometry. By measuring the magnitude of the response for each isotope and the response for the ''unique spike'' then relating this to the known quantity of the ''spike'', the quantity of the nuclear material can be determined. An automated spike preparation system was developed at the Savannah River Site (SRS) to dispense spikes for use in IDMS analytical methods. Prior to this development, technicians weighed each individual spike manually to achieve the accuracy required. This procedure was time-consuming and subjected the master stock solution to evaporation. The new system employs a high precision SMI Model 300 Unipump dispenser interfaced with an electronic balance and a portable Epson HX-20 notebook computer to automate spike preparation

  3. Automation of PCXMC and ImPACT for NASA Astronaut Medical Imaging Dose and Risk Tracking

    Science.gov (United States)

    Bahadori, Amir; Picco, Charles; Flores-McLaughlin, John; Shavers, Mark; Semones, Edward

    2011-01-01

    To automate astronaut organ and effective dose calculations from occupational X-ray and computed tomography (CT) examinations incorporating PCXMC and ImPACT tools and to estimate the associated lifetime cancer risk per the National Council on Radiation Protection & Measurements (NCRP) using MATLAB(R). Methods: NASA follows guidance from the NCRP on its operational radiation safety program for astronauts. NCRP Report 142 recommends that astronauts be informed of the cancer risks from reported exposures to ionizing radiation from medical imaging. MATLAB(R) code was written to retrieve exam parameters for medical imaging procedures from a NASA database, calculate associated dose and risk, and return results to the database, using the Microsoft .NET Framework. This code interfaces with the PCXMC executable and emulates the ImPACT Excel spreadsheet to calculate organ doses from X-rays and CTs, respectively, eliminating the need to utilize the PCXMC graphical user interface (except for a few special cases) and the ImPACT spreadsheet. Results: Using MATLAB(R) code to interface with PCXMC and replicate ImPACT dose calculation allowed for rapid evaluation of multiple medical imaging exams. The user inputs the exam parameter data into the database and runs the code. Based on the imaging modality and input parameters, the organ doses are calculated. Output files are created for record, and organ doses, effective dose, and cancer risks associated with each exam are written to the database. Annual and post-flight exposure reports, which are used by the flight surgeon to brief the astronaut, are generated from the database. Conclusions: Automating PCXMC and ImPACT for evaluation of NASA astronaut medical imaging radiation procedures allowed for a traceable and rapid method for tracking projected cancer risks associated with over 12,000 exposures. This code will be used to evaluate future medical radiation exposures, and can easily be modified to accommodate changes to the risk

  4. Drug dispensing errors in a ward stock system

    DEFF Research Database (Denmark)

    Andersen, Stig Ejdrup

    2010-01-01

    . Multivariable analysis showed that surgical and psychiatric settings were more susceptible to involvement in dispensing errors and that polypharmacy was a risk factor. In this ward stock system, dispensing errors are relatively common, they depend on speciality and are associated with polypharmacy......The aim of this study was to determine the frequency of drug dispensing errors in a traditional ward stock system operated by nurses and to investigate the effect of potential contributing factors. This was a descriptive study conducted in a teaching hospital from January 2005 to June 2007. In five....... These results indicate that strategies to reduce dispensing errors should address polypharmacy and focus on high-risk units. This should, however, be substantiated by a future trial....

  5. Dosing method of physical activity in aerobics classes for students

    Directory of Open Access Journals (Sweden)

    Yu.I. Beliak

    2014-10-01

    Full Text Available Purpose : reasons for the method of dosing of physical activity in aerobics classes for students. The basis of the method is the evaluation of the metabolic cost of funds used in them. Material : experiment involved the assessment of the pulse response of students to load complexes classical and step aerobics (n = 47, age 20-23 years. In complexes used various factors regulating the intensity: perform combinations of basic steps, involvement of movements with his hands, holding in hands dumbbells weighing 1kg increase in the rate of musical accompaniment, varying heights step platform. Results . on the basis of the relationship between heart rate and oxygen consumption was determined by the energy cost of each admission control load intensity. This indicator has been used to justify the intensity and duration of multiplicity aerobics. Figure correspond to the level of physical condition and motor activity deficits students. Conclusions : the estimated component of this method of dosing load makes it convenient for use in automated computer programs. Also it can be easily modified to dispense load other types of recreational fitness.

  6. Structure Design and Realization of Rapid Medicine Dispensing System

    Science.gov (United States)

    Liu, Xiangquan

    In this paper, the main components and function of rapid medicine dispensing system is analyzed, structure design of automatic feeding device, sloping storeroom, automatic dispensing device and automatic sorting device is completed. The system adopts medicine conveyer working in with manipulator to realize automatic batch supply of the boxed medicine, adopts sloping storeroom as warehouse of medicine to realize dense depositing, adopts dispensing mechanism which includes elevator, turning panel and electric magnet to realize rapid medicine dispensing, adopts sorting conveyor belt and sorting device to send medicine to designated outlet.

  7. One-Stop Dispensing

    DEFF Research Database (Denmark)

    Houlind, Morten Baltzer; McNulty, Helle Bach Ølgaard; Treldal, Charlotte

    2018-01-01

    (1) Objective: To assess hospital medication costs and staff time between One-Stop Dispensing (OSD) and the Traditional Medication System (TMS), and to evaluate patient perspectives on OSD. (2) Methods: The study was conducted at Hvidovre Hospital, University of Copenhagen, Denmark in an elective...... gastric surgery and acute orthopedic surgery department. This study consists of three sub-studies including adult patients able to self-manage medication. In Sub-study 1, staff time used to dispense and administer medication in TMS was assessed. Medication cost and OSD staff time were collected in Sub......-study 2, while patient perspectives were assessed in Sub-study 3. Medication costs with two days of discharge medication were compared between measured OSD cost and simulated TMS cost for the same patients. Measured staff time in OSD was compared to simulated staff time in TMS for the same patients...

  8. Enhancing Cooperative Loan Scheme Through Automated Loan ...

    African Journals Online (AJOL)

    Journal Home > Vol 6, No 1 (2013) > ... The concept of automation has been variously applied in most computing fields. ... competent capabilities to eliminate data inconsistency and redundancy as well as ensuring data integrity and security, ...

  9. Automatic dispensing of liquid nitrogen in submilliliter doses

    Science.gov (United States)

    Milner, C. J.

    1984-10-01

    Well-controlled doses of 0.2 to 0.5 ml of liquid nitrogen are delivered, on electrical signal (not more than once per 5 s), as fills of a miniature bucket raised by an automatic hoist. The bucket is lifted, brimming, from the storage flask and then moved sideways until over the receiver. At this point, a steel ball, which has been resting in and sealing a drain hole in the bucket, is lifted from its seat by a magnet fixed alongside the (now descending) bucket. Design features are outlined: some alternative designs, valving liquid through a short drain tube fixed in the storage flask, are briefly reviewed. In tests the device delivered 74 g (approx. 260 doses) during 63 min, the loss by evaporation meanwhile being 11 g from the bucket, implying a transfer efficiency of 87%. An indirect measure indicated the dose sizes as 354±10 μl approximately.

  10. Automated lung module detection at low-dose CT: preliminary experience

    International Nuclear Information System (INIS)

    Goo, Jin-Mo; Lee, Jeong-Won; Lee, Hyun-Ju; Kim, Seung-Wan; Kim, Jong-Hyo; Im, Jung-Gi

    2003-01-01

    To determine the usefulness of a computer-aided diagnosis (CAD) system for the automated detection of lung nodules at low-dose CT. A CAD system developed for detecting lung nodules was used to process the data provided by 50 consecutive low-dose CT scans. The results of an initial report, a second look review by two chest radiologists, and those obtained by the CAD system were compared, and by reviewing all of these, a gold standard was established. By applying the gold standard, a total of 52 nodules were identified (26 with a diameter ≤ 5 mm; 26 with a diameter > 5 mm). Compared to an initial report, four additional nodules were detected by the CAD system. Three of these, identified only at CAD, formed part of the data used to derive the gold standard. For the detection of nodules > 5 mm in diameter, sensitivity was 77% for the initial report, for the second look review, and 88% for the second look review,and 65% for the CAD system. There were 8.0 ± 5.2 false-positive CAD results per CT study. These preliminary results indicate that a CAD system may improve the detection of pulmonary nodules at low-dose CT

  11. Multi-dose drug dispensing as a tool to improve medication adherence: A study in patients using vitamin K antagonists.

    Science.gov (United States)

    van Rein, Nienke; de Geus, Kristel S; Cannegieter, Suzanne C; Reitsma, Pieter H; van der Meer, Felix J M; Lijfering, Willem M

    2018-01-01

    Multi-dose drug dispensing (MDD) is a dosing aid that provides patients with disposable bags containing all drugs intended for 1 dosing moment. MDD is believed to increase medication adherence, but studies are based on self-reported data, and results may depend on socially desirable answers. Therefore, our purpose was to determine the effect of MDD on medication adherence in non-adherent patients taking vitamin K antagonists (VKAs), and to compare with instructing patients on medication use. We conducted a before-after study in non-adherent patients where MDD was the exposure and change in adherence after MDD initiation was the outcome (within patient comparison). Time in therapeutic range (TTR) was selected as a measure for adherence, as this reflects stability of VKA treatment. To analyze whether MDD improved adherence as compared with standard care (ie, letters or calls from nurses of the anticoagulation clinic), non-adherent patients without MDD were also followed to estimate their TTR change over time (between patient comparison). Eighty-three non-adherent VKA patients started using MDD. The median TTR was 63% before MDD and 73% 6 months after MDD. The within patient TTR increased on average by 13% (95%CI 6% to 21%) within 1 month after starting MDD and remained stable during the next 5 months. The TTR of MDD-patients increased 10% (95%CI 2% to 19%) higher as compared with non-MDD patients within 1 month but was similar after 4 months (TTR difference 3%, 95%CI -2% to 9%). Adherence improved after initiation of MDD. Compared with instructing patients, MDD was associated with better adherence within 1 month but was associated with similar improvement after 4 months. Copyright © 2017 John Wiley & Sons, Ltd.

  12. SU-E-T-139: Automated Daily EPID Exit Dose Analysis Uncovers Treatment Variations

    Energy Technology Data Exchange (ETDEWEB)

    Olch, A [University of Southern California, Los Angeles, CA (United States)

    2015-06-15

    Purpose: To evaluate a fully automated EPID exit dose system for its ability to detect daily treatment deviations including patient setup, delivery, and anatomy changes. Methods: PerFRACTION (Sun Nuclear Corporation) software is a system that uses integrated EPID images taken during patient treatment and automatically pulled from the Aria database and analyzed based on user-defined comparisons. This was used to monitor 20 plans consisting of a total of 859 fields for 18 patients, for a total of 251 fractions. Nine VMAT, 5 IMRT, and 6 3D plans were monitored. The Gamma analysis was performed for each field within a plan, comparing the first fraction against each of the other fractions in each treatment course. A 2% dose difference, 1 mm distance-to-agreement, and 10% dose threshold was used. These tight tolerances were chosen to achieve a high sensitivity to treatment variations. The field passed if 93% of the pixels had a Gamma of 1 or less. Results: Twenty-nine percent of the fields failed. The average plan passing rate was 92.5%.The average 3D plan passing rate was less than for VMAT or IMRT, 84%, vs. an average of 96.2%. When fields failed, an investigation revealed changes in patient anatomy or setup variations, often also leading to variations of transmission through immobilization devices. Conclusion: PerFRACTION is a fully automated system for determining daily changes in dose transmission through the patient that requires no effort other than for the imager panel to be deployed during treatment. A surprising number of fields failed the analysis and can be attributed to important treatment variations that would otherwise not be appreciated. Further study of inter-fraction treatment variations is possible and warranted. Sun Nuclear Corporation provided a license to the software described.

  13. Antimalarial Drugs for Pediatrics - Prescribing and Dispensing ...

    African Journals Online (AJOL)

    Purpose: To assess dispensing and prescribing practices with regard to antimalarial drugs for pediatrics in private pharmacies and public hospitals in Dar es Salaam, Tanzania. Methods: This was a cross-sectional, descriptive study that assessed the knowledge and practice of 200 drug dispensers in the private community ...

  14. 14 CFR 137.39 - Economic poison dispensing.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  15. Fully automated gynecomastia quantification from low-dose chest CT

    Science.gov (United States)

    Liu, Shuang; Sonnenblick, Emily B.; Azour, Lea; Yankelevitz, David F.; Henschke, Claudia I.; Reeves, Anthony P.

    2018-02-01

    Gynecomastia is characterized by the enlargement of male breasts, which is a common and sometimes distressing condition found in over half of adult men over the age of 44. Although the majority of gynecomastia is physiologic or idiopathic, its occurrence may also associate with an extensive variety of underlying systemic disease or drug toxicity. With the recent large-scale implementation of annual lung cancer screening using low-dose chest CT (LDCT), gynecomastia is believed to be a frequent incidental finding on LDCT. A fully automated system for gynecomastia quantification from LDCT is presented in this paper. The whole breast region is first segmented using an anatomyorientated approach based on the propagation of pectoral muscle fronts in the vertical direction. The subareolar region is then localized, and the fibroglandular tissue within it is measured for the assessment of gynecomastia. The presented system was validated using 454 breast regions from non-contrast LDCT scans of 227 adult men. The ground truth was established by an experienced radiologist by classifying each breast into one of the five categorical scores. The automated measurements have been demonstrated to achieve promising performance for the gynecomastia diagnosis with the AUC of 0.86 for the ROC curve and have statistically significant Spearman correlation r=0.70 (p early detection as well as the treatment of both gynecomastia and the underlying medical problems, if any, that cause gynecomastia.

  16. A new protocol for evaluating the efficacy of some dispensing systems of a packaging in the microbial protection of water-based preservative-free cosmetic products.

    Science.gov (United States)

    Devlieghere, F; De Loy-Hendrickx, A; Rademaker, M; Pipelers, P; Crozier, A; De Baets, B; Joly, L; Keromen, S

    2015-12-01

    A new protocol is described for assessing the efficacy of the dispenser of some packaging systems (PSs) of preservative-free cosmetic products in protecting both their contained formula and their delivered doses. Practically, aiming at mimicking contacts with a non-sterile skin or fingers, the dispensing system is put into contact with a pre-contaminated fabric by a standardized colonization of P. aeruginosa. When applied to three different types of packaging, results show clear differences in both criteria between these conditioning articles, that is variable efficacies in protecting the contained product and the delivered doses, knowing that the first aspect is of paramount importance. The proposed protocol is proved being able to discriminate between different PSs and provides information on strong and weak features of certain types dispensing technologies prone to efficiently decrease either the dose contamination or to prevent contamination in reaching the contained product. Therefore, the proposed protocol can contribute to an objective selection of a PS for protecting a cosmetic care product with a low content of preservative or preservative free. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  17. Automated detection of lung nodules in low-dose computed tomography

    International Nuclear Information System (INIS)

    Cascio, D.; Cheran, S.C.; Chincarini, A.; De Nunzio, G.; Delogu, P.; Fantacci, M.E.; Gargano, G.; Gori, I.; Retico, A.; Masala, G.L.; Preite Martinez, A.; Santoro, M.; Spinelli, C.; Tarantino, T.

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (∝300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scan. (orig.)

  18. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Johnston, J.; Barker, K.; Ice, R.D.

    1982-01-01

    Dispensing trends for radiopharmaceuticals at a regional nuclear pharmacy over a 51-month period were studied. dispensing records of a regional nuclear pharmacy were analyzed with a forecasting procedure that uses univariate time data to produce time trends and autoregressive models. The overall number of prescriptions increased from 3500 to 5500 per quarter. Radiopharmaceuticals used in nuclear cardiology studies increased from less than 0.1% to 17.5% of total prescriptions dispensed, while radiopharmaceuticals used for brain imaging showed a steady decline from 29% to 11% of total prescriptions dispensed. The demand for other radiopharmaceuticals increased in areas such as renal studies, bone studies, lung studies, liver-function studies, and 67 Ga tumor-uptake studies, and declined slightly for static liver studies. Changes in dispensing trends for radiopharmaceuticals will continue as the practice of nuclear medicine concentrates more on functional studies and as newer imaging techniques become used for other purposes

  19. PROJECT OF COAGULANT DISPENSER IN PULVERIZATION AERATOR WITH WIND DRIVE

    Directory of Open Access Journals (Sweden)

    Ewa Osuch

    2017-09-01

    Full Text Available Lakes are one of most important freshwater ecosystems, playing significant role in functioning of nature and human economy. Swarzędzkie Lake is good example of ecosystem, which in last half-century was exposed to the influence of strong anthropopressure. Direct inflow of sewage with large number of biogens coming to the lake with water of inflows caused distinct disturbance of its functioning. In autumn 2011 restoration begined on Swarzędzkie Lake for reduction of lake trophy and improvement of water quality. For achieving better and quicker effect, simultaneously combination of some methods was applied, among others method of oxygenation of over-bottom water with help of pulverization aerator and method of precise inactivation of phosphorus in water depths. Characterization and analysis of improved coagulant dispenser applying active substance only during work of pulverization aerator is the aim of this thesis. Principle of dispenser work, its structure and location in pulverization aerator were explained. It was stated, that introduction to water a factor initiating process of phosphorus inactivation causes significant reduction of mineral phosphorus in water and size of coagulant dose correlates with intensity of work of pulverization aerator with wind drive.

  20. EDISON - research programme on electric distribution automation 1993-1997. Final report 1997

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M [ed.; VTT Energy, Espoo (Finland). Energy Systems

    1998-08-01

    This report comprises a summary of the results of the five year research programme EDISON on distribution automation in Finnish utilities. The research programme (1993 - 1997) was conducted under the leadership of VTT Energy, in cooperation with universities, distribution companies and the manufacturing industry. The main part of the funding has been from the Technology Development Centre TEKES and from manufacturing companies. The goal of the research programme was to develop a new scheme for a complete distribution automation system, including the network automation, computer systems in the control centre and the customer associated automation functions. In addition, the techniques for demand side management were developed and integrated into the automation scheme. The final aim was to demonstrate the automation functions and systems of the scheme in real distribution systems. The results of nineteen projects are given in this report

  1. 46 CFR 105.90-1 - Existing commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Existing commercial fishing vessels dispensing petroleum... AND MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Existing Commercial Fishing Vessels Dispensing Petroleum Products § 105.90-1 Existing commercial fishing vessels dispensing...

  2. 46 CFR 105.45-1 - Loading or dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Loading or dispensing petroleum products. 105.45-1... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Special Operating Requirements § 105.45-1 Loading or dispensing petroleum products. (a) A commercial fishing vessel must have aboard a letter of...

  3. TU-H-CAMPUS-JeP3-02: Automated Dose Accumulation and Dose Accuracy Assessment for Online Or Offline Adaptive Replanning

    International Nuclear Information System (INIS)

    Chen, G; Ahunbay, E; Li, X

    2016-01-01

    Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and considering patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.

  4. Providers′ knowledge, attitude and dispensing practices of E-Pills in government dispensaries of south district in Delhi, India

    Directory of Open Access Journals (Sweden)

    Kishore Vertika

    2010-01-01

    Full Text Available Background: South Delhi is one of the well developed districts in the capital with best public health care facilities. Knowledge, attitude and dispensing practices of emergency contraceptive pills (E-pills were assessed among health care providers of government dispensaries in South Delhi. Study Design: A descriptive epidemiological study. Materials and Methods: Both medical and paramedical (n = 428 providers in 63 government health care facilities were interviewed between August to December 2007 using a semi-structured interview schedule. Results: Among the different categories of the providers, medical officers were observed to be most knowledgeable about E-pills and the pharmacists were the least. The correct prescribed dose of E-pill was known only to 32% of the providers while 49% knew about its right time of intake. Misconceptions and apprehensions for promoting its use were very much prevalent even among medical officers as majority felt that open access to E-pills would increase promiscuity. The dispensing practice of providers was found positively ( P < 0.05 correlated with their knowledge. Training resulted a significant ( P < 0.05 improvement in knowledge, attitude and dispensing practice of the providers. Knowledge and training combined together contributed 35% to the dispensing practice (R 2 = 0.35. Conclusion: Besides knowledge, behavior change communication strategies should form a part of the training curricula of health care providers that would help to improve the dispensing practice of E-pills.

  5. Dispensing of non-prescribed antibiotics in Jordan

    Directory of Open Access Journals (Sweden)

    Almaaytah A

    2015-09-01

    Full Text Available Ammar Almaaytah,1 Tareq L Mukattash,2 Julia Hajaj2 1Department of Pharmaceutical Technology, 2Department of Clinical Pharmacy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid, Jordan Objective: Current regulations in Jordan state that antibiotics cannot be sold without a medical prescription. This study aimed to assess the percentage of pharmacies that dispense antibiotics without a medical prescription in the Kingdom of Jordan and identify and highlight the extent and seriousness of such practices among Jordanian pharmacies. Methods: A prospective study was performed, and five different clinical scenarios were simulated at pharmacies investigated including sore throat, otitis media, acute sinusitis, diarrhea, and urinary tract infection in childbearing-aged women. Three levels of demand were used to convince the pharmacists to sell an antibiotic. Results: A total of 202 total pharmacies in Jordan were visited in the present study. The majority of pharmacies (74.3% dispensed antibiotics without prescription with three different levels of demand. The percentage of pharmacies dispensing antibiotics without a prescription for the sore throat scenario was 97.6%, followed by urinary tract infection (83.3%, diarrhea (83%, and otitis media (68.4%. The lowest percentage of antibiotic dispensing was for the acute sinusitis simulation at 48.5%. Among the pharmacies that dispensed antibiotics, the pharmacists provided an explanation as the number of times per day the drug should be taken in 95.3% of the cases, explained the duration of treatment in 25.7%, and inquired about allergies prior to the sale of the antibiotic in only 17.3%. Only 52 pharmacies (25.7% refused to dispense any kind of antibiotics, the majority (61.5% of this refusal response came from acute sinusitis cases, while the minority (2.4% came from the sore throat cases. Conclusion: The results of this study demonstrate that antibiotics continue to be dispensed

  6. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    Science.gov (United States)

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  7. Rates of opioid dispensing and overdose after introduction of abuse-deterrent extended-release oxycodone and withdrawal of propoxyphene.

    Science.gov (United States)

    Larochelle, Marc R; Zhang, Fang; Ross-Degnan, Dennis; Wharam, J Frank

    2015-06-01

    In the second half of 2010, abuse-deterrent extended-release oxycodone hydrochloride (OxyContin; Purdue Pharma) was introduced and propoxyphene was withdrawn from the US market. The effect of these pharmaceutical market changes on opioid dispensing and overdose rates is unknown. To evaluate the association between 2 temporally proximate changes in the opioid market and opioid dispensing and overdose rates. Claims from a large national US health insurer were analyzed, using an interrupted time series study design. Participants included an open cohort of 31.3 million commercially insured members aged 18 to 64 years between January 1, 2003, and December 31, 2012, with median follow-up of 20 months (last follow-up, December 31, 2012). Introduction of abuse-deterrent OxyContin (resistant to crushing or dissolving) on August 9, 2010, and market withdrawal of propoxyphene on November 19, 2010. Standardized opioid dispensing rates and prescription opioid and heroin overdose rates were the primary outcomes. We used segmented regression to analyze changes in outcomes from 30 quarters before to 8 quarters after the 2 interventions. Two years after the opioid market changes, total opioid dispensing decreased by 19% from the expected rate (absolute change, -32.2 mg morphine-equivalent dose per member per quarter [95% CI, -38.1 to -26.3]). By opioid subtype, the absolute change in dispensing by milligrams of morphine-equivalent dose per member per quarter at 2 years was -11.3 (95% CI, -12.4 to -10.1) for extended-release oxycodone, 3.26 (95% CI, 1.40 to 5.12) for other long-acting opioids, -8.19 (95% CI, -9.30 to -7.08) for propoxyphene, and -16.2 (95% CI, -18.8 to -13.5) for other immediate-release opioids. Two years after the market changes, the estimated overdose rate attributed to prescription opioids decreased by 20% (absolute change, -1.10 per 100,000 members per quarter [95% CI, -1.47 to -0.74]), but heroin overdose increased by 23% (absolute change, 0.26 per 100

  8. The K-1 Active Dispenser for Orbit Transfer

    Science.gov (United States)

    Lai, G.; Cochran, D.; Curtis, R.

    2002-01-01

    Kistler Aerospace Corporation is building the K-1, the world's first fully reusable launch vehicle. The two-stage K- 1 is designed primarily to service the market for low-earth orbit (LEO) missions, due to Kistler's need to recover both stages. For customers requiring payload delivery to high-energy orbits, Kistler can outfit the payload with a K- 1 Active Dispenser (an expendable third stage). The K-1 second stage will deploy the Active Dispenser mated with its payload into a 200 km circular LEO parking orbit. From this orbit, the Active Dispenser would use its own propulsion to place its payload into the final desired drop-off orbit or earth-escape trajectory. This approach allows Kistler to combine the low-cost launch services offered by the reusable two-stage K-1 with the versatility of a restartable, expendable upper stage. Enhanced with an Active Dispenser, the K-1 will be capable of delivering 1,500 kg to a geosynchronous transfer orbit or up to approximately 1,000 kg into a Mars rendezvous trajectory. The list price of a K-1 Active Dispenser launch is 25 million (plus the price of mission unique integration services) significantly less than the price of any launch vehicle service in the world with comparable capability.

  9. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

    International Nuclear Information System (INIS)

    Jennings, G

    2016-01-01

    Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe

  10. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

    Energy Technology Data Exchange (ETDEWEB)

    Jennings, G [Marsden Medical Physics Associates, Denville, NJ (United States)

    2016-06-15

    Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe.

  11. Automated high-dose rate brachytherapy treatment planning for a single-channel vaginal cylinder applicator

    Science.gov (United States)

    Zhou, Yuhong; Klages, Peter; Tan, Jun; Chi, Yujie; Stojadinovic, Strahinja; Yang, Ming; Hrycushko, Brian; Medin, Paul; Pompos, Arnold; Jiang, Steve; Albuquerque, Kevin; Jia, Xun

    2017-06-01

    High dose rate (HDR) brachytherapy treatment planning is conventionally performed manually and/or with aids of preplanned templates. In general, the standard of care would be elevated by conducting an automated process to improve treatment planning efficiency, eliminate human error, and reduce plan quality variations. Thus, our group is developing AutoBrachy, an automated HDR brachytherapy planning suite of modules used to augment a clinical treatment planning system. This paper describes our proof-of-concept module for vaginal cylinder HDR planning that has been fully developed. After a patient CT scan is acquired, the cylinder applicator is automatically segmented using image-processing techniques. The target CTV is generated based on physician-specified treatment depth and length. Locations of the dose calculation point, apex point and vaginal surface point, as well as the central applicator channel coordinates, and the corresponding dwell positions are determined according to their geometric relationship with the applicator and written to a structure file. Dwell times are computed through iterative quadratic optimization techniques. The planning information is then transferred to the treatment planning system through a DICOM-RT interface. The entire process was tested for nine patients. The AutoBrachy cylindrical applicator module was able to generate treatment plans for these cases with clinical grade quality. Computation times varied between 1 and 3 min on an Intel Xeon CPU E3-1226 v3 processor. All geometric components in the automated treatment plans were generated accurately. The applicator channel tip positions agreed with the manually identified positions with submillimeter deviations and the channel orientations between the plans agreed within less than 1 degree. The automatically generated plans obtained clinically acceptable quality.

  12. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    Science.gov (United States)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  13. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    International Nuclear Information System (INIS)

    De Vos, Marc; Torah, Russel; Tudor, John

    2016-01-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps. (paper)

  14. Intelligent control of liquid transfer for the automated synthesis of positron emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Iwata, Ren; Ido, Tatsuo; Yamazaki, Shigeki

    1990-01-01

    A method for the intelligent control of liquid transfer, developed for automated synthesis of 2-deoxy-2-[ 18 F]fluoro-D-glucose from [ 18 F]fluoride, is described. A thermal mass flow controller coupled to a personal computer is used to monitor conditions for transferring or passing liquid through a tube or a column. Using this sensor a computer can detect completion of liquid transfer, dispense a stock solution and check the setup conditions of the system. The present feedback control can be readily adapted to other automated syntheses of positron emitting radiopharmaceuticals. (author)

  15. Construction of a smart medication dispenser with high degree of scalability and remote manageability.

    Science.gov (United States)

    Pak, JuGeon; Park, KeeHyun

    2012-01-01

    We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT). In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  16. Construction of a Smart Medication Dispenser with High Degree of Scalability and Remote Manageability

    Directory of Open Access Journals (Sweden)

    JuGeon Pak

    2012-01-01

    Full Text Available We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT. In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  17. EDISON - research programme on electricity distribution automation 1993-1997. Interim report 1995

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M. [ed.] [VTT Energy, Espoo (Finland). Energy Systems

    1996-12-31

    The report comprises a summary of the results of the first three years of the research programme EDISON on distribution automation in Finnish electrical utilities. The five year research programme (1993-1997) is conducted under the leadership of VTT Energy, in cooperation with universities, distribution companies and the manufacturing industry. The main part of funding is from the Technology Development Centre (Tekes) and from manufacturing companies. The goal of the research programme is to develop a new scheme for a complete distribution automation system, including the network automation, computer systems in the control centre and the customer automation functions. In addition, the techniques for demand side management are developed and integrated into the automation scheme. The final aim is to demonstrate the automation functions and systems of the scheme in real distribution systems. The results of thirteen projects are now given. These results should be considered intermediate, since most projects will be continued in 1996. (orig.)

  18. EDISON - research programme on electricity distribution automation 1993-1997. Interim report 1996

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M. [ed.] [VTT Energy, Espoo (Finland). Energy Systems

    1997-12-31

    The report comprises a summary of the results of the first four years of the research programme EDISON on distribution automation in Finnish utilities. The five year research programme (1993-1997) is conducted under the leadership of VTT Energy, in cooperation with universities, distribution companies and the manufacturing industry. The main part of the funding is from the Technology Development Centre TEKES and from manufacturing companies. The goal of the research programme is to develop a new scheme for a complete distribution automation system, including the network automation, computer systems in the control centre and the customer associated automation functions. In addition, the techniques for demand side management are developed and integrated into the automation scheme. The final aim is to demonstrate the automation functions and systems of the scheme in real distribution systems. The results of fifteen projects are now given. These results should be considered intermediate, since most projects will be continued in 1997. (orig.) 43 refs.

  19. EDISON - research programme on electricity distribution automation 1993-1997. Interim report 1995

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M [ed.; VTT Energy, Espoo (Finland). Energy Systems

    1997-12-31

    The report comprises a summary of the results of the first three years of the research programme EDISON on distribution automation in Finnish electrical utilities. The five year research programme (1993-1997) is conducted under the leadership of VTT Energy, in cooperation with universities, distribution companies and the manufacturing industry. The main part of funding is from the Technology Development Centre (Tekes) and from manufacturing companies. The goal of the research programme is to develop a new scheme for a complete distribution automation system, including the network automation, computer systems in the control centre and the customer automation functions. In addition, the techniques for demand side management are developed and integrated into the automation scheme. The final aim is to demonstrate the automation functions and systems of the scheme in real distribution systems. The results of thirteen projects are now given. These results should be considered intermediate, since most projects will be continued in 1996. (orig.)

  20. 46 CFR 105.05-1 - Commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Commercial fishing vessels dispensing petroleum products... MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Application § 105.05-1 Commercial fishing vessels dispensing petroleum products. (a) The provisions of this part, with the exception of...

  1. Energy-efficiency potential of water dispensers; Energieeffizienzpotenzial bei Wasser-Dispensern

    Energy Technology Data Exchange (ETDEWEB)

    Grieder, T.

    2003-07-01

    This final report for the Swiss Federal Office of Energy presents the results of study carried out to assess the energy-savings potential available in the operation of water dispensers often found in banks, stores and offices. The energy consumption of three types of dispenser is examined and compared with American 'EnergyStar'-guidelines. The results of measurements made for day and night-time operation are presented and the energy-savings potentials offered by more appropriate operating scenarios are discussed. Recommendations are made to all parties involved, from the dispenser's manufacturer, water-supplier and service organisation through to the end user. For each category, a catalogue of measures that can be taken is presented, including modifications to the dispensers themselves and the installation of timers. Also, the energy consumption of dispensers is compared with that of using traditional mineral water bottles and a small conventional refrigerator.

  2. Slow Release of Plant Volatiles Using Sol-Gel Dispensers.

    Science.gov (United States)

    Bian, L; Sun, X L; Cai, X M; Chen, Z M

    2014-12-01

    The black citrus aphid, also known as the tea aphid, (Toxoptera aurantii Boyer) attacks economically important crops, including tea (Camellia sinensis (L.) O. Kuntze). In the current study, silica sol-gel formulations were screened to find one that could carry and release C. sinensis plant volatiles to lure black citrus aphids in a greenhouse. The common plant volatile trans-2-hexen-1-al was used as a model molecule to screen for suitable sol-gel formulations. A zNose (Electronic Sensor Technology, Newbury Park, CA) transportable gas chromatograph was used to continuously monitor the volatile emissions. A sol-gel formulation containing tetramethyl orthosilicate and methyltrimethoxysilane in an 8:2 (vol:vol) ratio was selected to develop a slow-release dispenser. The half-life of trans-2-hexen-1-al in the sol-gel dispenser increased slightly with the volume of this compound in the dispenser. Ten different volatiles were tested in the sol-gel dispenser. Alcohols of 6-10 carbons had the longest half-lives (3.01-3.77 d), while esters of 6-12 carbons had the shortest (1.53-2.28 d). Release of these volatiles from the dispensers could not be detected by the zNose after 16 d (cis-3-hexenyl acetate) to 26 d (3,7-dimethylocta-1,6-dien-3-ol). In greenhouse experiments, trans-2-hexen-1-al and cis-3-hexen-1-ol released from the sol-gel dispensers attracted aphids for ≍17 d, and release of these volatiles could not be detected by the zNose after ≍24 d. The sol-gel dispensers performed adequately for the slow release of plant volatiles to trap aphids in the greenhouse. © 2014 Entomological Society of America.

  3. A correction scheme for a simplified analytical random walk model algorithm of proton dose calculation in distal Bragg peak regions

    Science.gov (United States)

    Yao, Weiguang; Merchant, Thomas E.; Farr, Jonathan B.

    2016-10-01

    The lateral homogeneity assumption is used in most analytical algorithms for proton dose, such as the pencil-beam algorithms and our simplified analytical random walk model. To improve the dose calculation in the distal fall-off region in heterogeneous media, we analyzed primary proton fluence near heterogeneous media and propose to calculate the lateral fluence with voxel-specific Gaussian distributions. The lateral fluence from a beamlet is no longer expressed by a single Gaussian for all the lateral voxels, but by a specific Gaussian for each lateral voxel. The voxel-specific Gaussian for the beamlet of interest is calculated by re-initializing the fluence deviation on an effective surface where the proton energies of the beamlet of interest and the beamlet passing the voxel are the same. The dose improvement from the correction scheme was demonstrated by the dose distributions in two sets of heterogeneous phantoms consisting of cortical bone, lung, and water and by evaluating distributions in example patients with a head-and-neck tumor and metal spinal implants. The dose distributions from Monte Carlo simulations were used as the reference. The correction scheme effectively improved the dose calculation accuracy in the distal fall-off region and increased the gamma test pass rate. The extra computation for the correction was about 20% of that for the original algorithm but is dependent upon patient geometry.

  4. Preliminary evaluation of second harmonic direct detection scheme for low-dose range in alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Chen, Felipe; Graeff, Carlos F.O.; Baffa, Oswaldo

    2002-01-01

    The usefulness of a direct detection scheme of the second harmonic (2h) overmodulated signal from irradiated alanine in EPR dosimetry was studied. For this purpose, a group of DL-alanine/paraffin cylindrical pellets was produced. The dosimeters were irradiated with a 60 Co radiotherapy gamma source with doses of 0.05, 0.1, 0.5, 1 and 5 Gy. The EPR measurements were carried out in a VARIAN-E4 spectrometer operating in X-band with optimized parameters to obtain highest amplitude signals of both harmonics. The 2h signal was detected directly at twice the modulation frequency. In preliminary results, the 2h showed some advantages over the 1h such as better resolution for doses below 1 Gy, better repeatability results and better linear behaviour in the dose range indicated. (author)

  5. The fabrication of front electrodes of Si solar cell by dispensing printing

    International Nuclear Information System (INIS)

    Kim, Do-Hyung; Ryu, Sung-Soo; Shin, Dongwook; Shin, Jung-Han; Jeong, Jwa-Jin; Kim, Hyeong-Jun; Chang, Hyo Sik

    2012-01-01

    Highlights: ► We propose the process for the front silver electrode by employing dispensing method. ► The dispensing method is a non-contact printing process. ► The electrode by dispensing method has more uniform and narrower shape. ► The dispensing method helped to enhance the efficiency of solar cell by 0.8% absolute. - Abstract: The dispensing printing was applied to fabricate the front electrodes of silicon solar cell. In this method, a micro channel nozzle and normal Ag paste were employed. The aspect ratio and line width of electrodes could be controlled by the process variables such as the inner diameter of nozzle, dispensing speed, discharge pressure, and the gap between wafer and nozzle. For the nozzle with the inner diameter of 50 μm, the line width and aspect ratio of electrode were under 90 μm and more than ∼0.2, respectively. When comparing the efficiency of solar cell prepared by conventional screen printing and the dispensing printing, the latter exhibited 19.1%, which is 0.8% absolute higher than the former even with the same Ag paste. This is because the electrode by dispensing printing has uniform aspect ratio and narrow line width over the length of electrode.

  6. Automated diagnostic kiosk for diagnosing diseases

    Science.gov (United States)

    Regan, John Frederick; Birch, James Michael

    2014-02-11

    An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

  7. Pharmacoepidemiological Data from Drug Dispensing Charities as a Measure of Health Patterns in a Population not Assisted by the Italian National Health Service.

    Science.gov (United States)

    Bini, Silvia; Cerri, Cesare; Rigamonti, Antonello E; Bertazzi, Pietro A; Fiorini, Gianfrancesco; Cella, Silvano G

    2016-08-19

    We analysed drug dispensation by charitable organisations in a year time. Drugs were grouped according to the Anatomic Therapeutic Chemical classification and the amount dispensed was calculated with the system of the Daily Defined Dose (DDD) and expressed as DDD/1000 subjects/day. A number of 87,550 subjects were studied (13,308 Italians; 74,242 Immigrants). Though we noticed a great sesonal variability, the drugs most frequently dispensed were those for the respiratory, cardiovascular and gastrointestinal system and antibiotics, which is different from the rest of the Italian population and the immigrant population assisted by our National Health Service (NHS). We also found that chronic diseases are increasing in these subjects. We conclude that the subjects not receiving NHS assitance have, at least in part, different health patterns and requirements. This should be considered when planning tailored interventions.

  8. Pharmacoepidemiological data from drug dispensing charities as a measure of health patterns in a population not assisted by the Italian National Health Service

    Directory of Open Access Journals (Sweden)

    Silvia Bini

    2016-08-01

    Full Text Available We analysed drug dispensation by charitable organisations in a year time. Drugs were grouped according to the Anatomic Therapeutic Chemical classification and the amount dispensed was calculated with the system of the Daily Defined Dose (DDD and expressed as DDD/1000 subjects/day. A number of 87,550 subjects were studied (13,308 Italians; 74,242 Immigrants. Though we noticed a great sesonal variability, the drugs most frequently dispensed were those for the respiratory, cardiovascular and gastrointestinal system and antibiotics, which is different from the rest of the Italian population and the immigrant population assisted by our National Health Service (NHS. We also found that chronic diseases are increasing in these subjects. We conclude that the subjects not receiving NHS assitance have, at least in part, different health patterns and requirements. This should be considered when planning tailored interventions.

  9. Volumetric dispenser for small particles from plural sources

    International Nuclear Information System (INIS)

    Bradley, R.A.; Miller, W.H.; Sease, J.D.

    1975-01-01

    Apparatus is described for rapidly and accurately dispensing measured volumes of small particles from a supply hopper. The apparatus includes an adjustable, vertically oriented measuring tube and orifice member defining the volume to be dispensed, a ball plug valve for selectively closing the bottom end of the orifice member, and a compression valve for selectively closing the top end of the measuring tube. A supply hopper is disposed above and in gravity flow communication with the measuring tube. Properly sequenced opening and closing of the two valves provides accurate volumetric discharge through the ball plug valve. A dispensing system is described wherein several appropriately sized measuring tubes, orifice members, and associated valves are arranged to operate contemporaneously to facilitate blending of different particles

  10. Use of simulated patients to evaluate combined oral contraceptive dispensing practices of community pharmacists.

    Directory of Open Access Journals (Sweden)

    Paulo Roque Obreli-Neto

    Full Text Available BACKGROUND: Combined oral contraceptive (COC use is the most commonly used reversible method of birth control. The incorrect use of COCs is frequent and one of the most common causes of unintended pregnancies. Community pharmacists (CPs are in a strategic position to improve COC use because they are the last health professional to interact with patients before drug use. OBJECTIVE: To evaluate the COC dispensing practices of CPs in a developing country. METHOD: A cross-sectional study was conducted in community pharmacies of Assis and Ourinhos microregions, Brazil, between June 1, 2012, and October 30, 2012. Four simulated patients (SPs (with counseled audio recording visited community pharmacies with a prescription for Ciclo 21(® (a COC containing ethinyl estradiol 30 mcg + levonorgestrel 15 mcg. The audio recording of every SP visit was listened to independently by 3 researchers to evaluate the COC dispensing practice. The percentage of CPs who performed a screening for safe use of COCs (i.e., taking of patients' medical and family history, and measuring of blood pressure and provided counseling, as well as the quality of the screening and counseling, were evaluated. RESULTS: Of the 185 CPs contacted, 41 (22.2% agreed to participate in the study and finished the study protocol. Only 3 CPs asked the SP a question (1 question asked by each professional, and all of the questions were closed-ended, viz., "do you smoke?" (n = 2 and "what is your age?" (n = 1. None of the CPs measured the patient's blood pressure. Six CPs provided counseling when dispensing COCs (drug dosing, 5 CPs; possible adverse effects, 2 CPs, and one CP provided counseling regarding both aspects. CONCLUSION: The CPs evaluated did not dispense COC appropriately and could influence in the occurrence of negatives therapeutic outcomes such as adverse effects and treatment failure.

  11. Automated flaw detection scheme for cast austenitic stainless steel weld specimens using Hilbert-Huang transform of ultrasonic phased array data

    International Nuclear Information System (INIS)

    Khan, Tariq; Majumdar, Shantanu; Udpa, Lalita; Ramuhalli, Pradeep; Crawford, Susan; Diaz, Aaron; Anderson, Michael T.

    2012-01-01

    The objective of this work is to develop processing algorithms to detect and localize flaws using ultrasonic phased-array data. Data was collected on cast austenitic stainless stell (CASS) weld specimens onloan from the U.S. nuclear power industry' Pressurized Walter Reactor Owners Group (PWROG) traveling specimen set. Each specimen consists of a centrifugally cast stainless stell (CCSS) pipe section welded to a statically cst(SCSS) or wrought (WRSS) section. The paper presents a novel automated flaw detection and localization scheme using low frequency ultrasonic phased array inspection singals from the weld and heat affected zone of the based materials. The major steps of the overall scheme are preprocessing and region of interest (ROI) detection followed by the Hilbert-Huang transform (HHT) of A-scans in the detected ROIs. HHT offers time-frequency-energy distribution for each ROI. The Accumulation of energy in a particular frequency band is used as a classification feature for the particular ROI

  12. Anthelmintic drug dispensing in South Africa: An analysis of ...

    African Journals Online (AJOL)

    More than two billion people worldwide are infected with helminths. The primary aim of the study was to evaluate the dispensing patterns of anthelmintic products using dispensing data of South African community pharmacies. A retrospective, cross-sectional drug utilisation study was conducted on a 2013 community ...

  13. Operational experience with the control scheme for IUAC linac booster

    International Nuclear Information System (INIS)

    Sahu, B.K.; Antony, J.; Mathuria, D.S.; Pandey, A.; Ghosh, S.; Mehta, R.; Rai, A.; Patra, P.; Choudhury, G.K.; Singh, K.; Ajith Kumar, B.P.; Kanjilal, D.; Roy, A.

    2009-01-01

    Accelerated beam from the first superconducting linear accelerator (linac) module of IUAC has been delivered to the user. The linac control scheme has worked successfully with the existing pelletron control scheme. Local RF control system consisting of Resonator controller and supporting RF modules are used for multipactoring conditioning, high power pulse conditioning and for the phase/amplitude locking of the superconducting resonators. Beam acceleration is done by adjusting the RF phase of each resonator with respect to master oscillator. The automation of control scheme is planned for smooth operation of linac with minimum human intervention. Python software support is added for writing automation routines in present control system software. An alternate tuning mechanism based on piezoelectric actuators has been successfully tested. (author)

  14. Adaptive Liver Stereotactic Body Radiation Therapy: Automated Daily Plan Reoptimization Prevents Dose Delivery Degradation Caused by Anatomy Deformations

    Energy Technology Data Exchange (ETDEWEB)

    Leinders, Suzanne M. [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Delft University of Technology, Delft (Netherlands); Breedveld, Sebastiaan; Méndez Romero, Alejandra [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Schaart, Dennis [Delft University of Technology, Delft (Netherlands); Seppenwoolde, Yvette, E-mail: y.seppenwoolde@erasmusmc.nl [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Heijmen, Ben J.M. [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands)

    2013-12-01

    Purpose: To investigate how dose distributions for liver stereotactic body radiation therapy (SBRT) can be improved by using automated, daily plan reoptimization to account for anatomy deformations, compared with setup corrections only. Methods and Materials: For 12 tumors, 3 strategies for dose delivery were simulated. In the first strategy, computed tomography scans made before each treatment fraction were used only for patient repositioning before dose delivery for correction of detected tumor setup errors. In adaptive second and third strategies, in addition to the isocenter shift, intensity modulated radiation therapy beam profiles were reoptimized or both intensity profiles and beam orientations were reoptimized, respectively. All optimizations were performed with a recently published algorithm for automated, multicriteria optimization of both beam profiles and beam angles. Results: In 6 of 12 cases, violations of organs at risk (ie, heart, stomach, kidney) constraints of 1 to 6 Gy in single fractions occurred in cases of tumor repositioning only. By using the adaptive strategies, these could be avoided (<1 Gy). For 1 case, this needed adaptation by slightly underdosing the planning target volume. For 2 cases with restricted tumor dose in the planning phase to avoid organ-at-risk constraint violations, fraction doses could be increased by 1 and 2 Gy because of more favorable anatomy. Daily reoptimization of both beam profiles and beam angles (third strategy) performed slightly better than reoptimization of profiles only, but the latter required only a few minutes of computation time, whereas full reoptimization took several hours. Conclusions: This simulation study demonstrated that replanning based on daily acquired computed tomography scans can improve liver stereotactic body radiation therapy dose delivery.

  15. Impact of Robotic Dispensing Machines in German Pharmacies on ...

    African Journals Online (AJOL)

    To assess the impact of robotic dispensing machines in community pharmacies on staff efficiency and sales of over-the-counter drugs. Setting: The study was done on 253 community pharmacies in Germany that use a robotic dispensing machine manufactured by ROWA during 2008. Method: Data concerning the financial ...

  16. Influence of container structures and content solutions on dispensing time of ophthalmic solutions

    Directory of Open Access Journals (Sweden)

    Keiji Yoshikawa

    2010-05-01

    Full Text Available Keiji Yoshikawa1, Hiroshi Yamada21Yoshikawa Eye Clinic, Tokyo, Japan; 2Santen Pharmaceutical Co., Ltd., Osaka, JapanPurpose: To investigate the influence of container structures and content solutions on the time of dispensing from eye dropper bottles.Methods: Eye dropper bottle models, solution models (filtrate water/surfactant solution and a dispensing time measuring apparatus were prepared to measure the dispensing time.Results: With filtrate water and pressure thrust load of 0.3 MPa, the dispensing time significantly increased from 1.1 ± 0.5 seconds to 4.6 ± 1.1 seconds depending on the decrease of inner aperture diameters from 0.4 mm to 0.2 mm (P < 0.0001. When using the bottle models with inner aperture diameters of 0.4 mm or larger, the dispensing time became constant. The dispensing time using surfactant solution showed the same tendency as above. When pressure thrust load was large (0.07 MPa, the solution flew out continuously with inner aperture diameters of 0.4 mm or larger and the dispensing time could not be measured. The inner aperture diameter most strongly explained the variation of the dispensing time in both the content solutions in the multiple linear regression analysis (filtrate water: 46%, R2 = 0.462, surfactant solution: 56%, R2 = 0.563.Conclusions: Among content solutions and container structures, the dispensing time was mostly influenced by the diameter of the inner aperture of bottles.Keywords: dispensing time, model eye dropper bottle, model ophthalmic solution, nozzle internal space volume, nozzle inner aperture diameter

  17. Confined prostate cancer treated by conformational irradiation with intensity modulation with or without echography repositioning: is the dose received equivalent to the prescribed dose?; Cancer prostatique localise traite par irradiation conformationnelle avec modulation d'intensite avec ou sans repositionnement echographique: la dose recue est-elle equivalente a la dose prescrite?

    Energy Technology Data Exchange (ETDEWEB)

    Arnaud, A.; Peignaux, K.; Brenier, J.P.; Truc, G.; Naudy, S.; Maingon, P.; Crehange, G. [Centre Georges-Francois Leclerc, Dept. de Radiotherapie, 21 - Dijon (France); Regis, A. [CHU le Bocage, Service de Radiodiagnostic, 21 - Dijon (France); Deville, C.; Bonnetain, F. [Centre Georges-Francois Leclerc, Dept. de Biostatique, 21 - Dijon (France)

    2006-11-15

    The results suggest it would be possible to dispense a homogenous dose in agreement with the ICRU recommendations, nearer than the forward looking dose when the daily echographic repositioning is applied. This repositioning does not influence significantly the dosimetry for the risk organs. These results will validated in a bigger population. (N.C.)

  18. Controlled Substance Reconciliation Accuracy Improvement Using Near Real-Time Drug Transaction Capture from Automated Dispensing Cabinets.

    Science.gov (United States)

    Epstein, Richard H; Dexter, Franklin; Gratch, David M; Perino, Michael; Magrann, Jerry

    2016-06-01

    Accurate accounting of controlled drug transactions by inpatient hospital pharmacies is a requirement in the United States under the Controlled Substances Act. At many hospitals, manual distribution of controlled substances from pharmacies is being replaced by automated dispensing cabinets (ADCs) at the point of care. Despite the promise of improved accountability, a high prevalence (15%) of controlled substance discrepancies between ADC records and anesthesia information management systems (AIMS) has been published, with a similar incidence (15.8%; 95% confidence interval [CI], 15.3% to 16.2%) noted at our institution. Most reconciliation errors are clerical. In this study, we describe a method to capture drug transactions in near real-time from our ADCs, compare them with documentation in our AIMS, and evaluate subsequent improvement in reconciliation accuracy. ADC-controlled substance transactions are transmitted to a hospital interface server, parsed, reformatted, and sent to a software script written in Perl. The script extracts the data and writes them to a SQL Server database. Concurrently, controlled drug totals for each patient having care are documented in the AIMS and compared with the balance of the ADC transactions (i.e., vending, transferring, wasting, and returning drug). Every minute, a reconciliation report is available to anesthesia providers over the hospital Intranet from AIMS workstations. The report lists all patients, the current provider, the balance of ADC transactions, the totals from the AIMS, the difference, and whether the case is still ongoing or had concluded. Accuracy and latency of the ADC transaction capture process were assessed via simulation and by comparison with pharmacy database records, maintained by the vendor on a central server located remotely from the hospital network. For assessment of reconciliation accuracy over time, data were collected from our AIMS from January 2012 to June 2013 (Baseline), July 2013 to April 2014

  19. Automated treatment planning engine for prostate seed implant brachytherapy

    International Nuclear Information System (INIS)

    Yu Yan; Zhang, J.B.Y.; Brasacchio, Ralph A.; Okunieff, Paul G.; Rubens, Deborah J.; Strang, John G.; Soni, Arvind; Messing, Edward M.

    1999-01-01

    Purpose: To develop a computer-intelligent planning engine for automated treatment planning and optimization of ultrasound- and template-guided prostate seed implants. Methods and Materials: The genetic algorithm was modified to reflect the 2D nature of the implantation template. A multi-objective decision scheme was used to rank competing solutions, taking into account dose uniformity and conformity to the planning target volume (PTV), dose-sparing of the urethra and the rectum, and the sensitivity of the resulting dosimetry to seed misplacement. Optimized treatment plans were evaluated using selected dosimetric quantifiers, dose-volume histogram (DVH), and sensitivity analysis based on simulated seed placement errors. These dosimetric planning components were integrated into the Prostate Implant Planning Engine for Radiotherapy (PIPER). Results: PIPER has been used to produce a variety of plans for prostate seed implants. In general, maximization of the minimum peripheral dose (mPD) for given implanted total source strength tended to produce peripherally weighted seed patterns. Minimization of the urethral dose further reduced the loading in the central region of the PTV. Isodose conformity to the PTV was achieved when the set of objectives did not reflect seed positioning uncertainties; the corresponding optimal plan generally required fewer seeds and higher source strength per seed compared to the manual planning experience. When seed placement uncertainties were introduced into the set of treatment planning objectives, the optimal plan tended to reach a compromise between the preplanned outcome and the likelihood of retaining the preferred outcome after implantation. The reduction in the volatility of such seed configurations optimized under uncertainty was verified by sensitivity studies. Conclusion: An automated treatment planning engine incorporating real-time sensitivity analysis was found to be a useful tool in dosimetric planning for prostate

  20. The dependence of the magnitude of induced adaptive responseon on the dose of pre-irradiation of cultured human lymphocytes under the optimum irradiation time scheme

    International Nuclear Information System (INIS)

    Mortazavi, S.M.J.; Mozdarani, H.

    2000-01-01

    Human lymphocytes exposed to low doses of X-rays, become less susceptible to the induction of chromosome aberrations by subsequent exposure to high doses of X-rays. This has been termed the radioadaptive response. One of the most important questions in the adaptive response studies was that of the possible existence of an optimum adapting dose. Early experiments indicated that this response could be induced by low doses of X-rays from 1 cGy to 20 cGy. Recently, it has been interestingly shown that the time scheme of exposure to adapting and challenge doses plays an important role in determination of the magnitude of the induced adaptive response. In this study, using the optimum irradiation time scheme (24-48), we have monitored the cytogenetic endpoint of chromosome aberrations to assess the magnitude of adaptation to ionizing radiation in the cultured human lymphocytes. Lymphocytes were pre-exposed to an adapting dose of 1-20 cGy at 24 hours, before an acute challenge dose of 1 or 2 Gy at 48 hours. Cells were fixed at 54 hours. Lymphocytes, which were pretreated with 5 as well as 10 cGy adapting doses, had significantly fewer chromosome aberrations. In spite of the fact that lymphocytes of some of our blood donors which were pre-treated with 1 or 20 cGy adapting doses, showed an adaptive response, the pooled data (all donors) indicated that such an induction of adaptive response can not be observed in these lymphocytes. The overall pattern of the induced adaptive response, indicated that in human lymphocyte (at least under the above mentioned irradiation scheme), 5 cGy and 10 cGy adapting doses are the optimum doses. (author)

  1. SU-F-T-440: The Feasibility Research of Checking Cervical Cancer IMRT Pre- Treatment Dose Verification by Automated Treatment Planning Verification System

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X; Yin, Y; Lin, X [Shandong Cancer Hospital and Institute, China, Jinan, Shandong (China)

    2016-06-15

    Purpose: To assess the preliminary feasibility of automated treatment planning verification system in cervical cancer IMRT pre-treatment dose verification. Methods: The study selected randomly clinical IMRT treatment planning data for twenty patients with cervical cancer, all IMRT plans were divided into 7 fields to meet the dosimetric goals using a commercial treatment planning system(PianncleVersion 9.2and the EclipseVersion 13.5). The plans were exported to the Mobius 3D (M3D)server percentage differences of volume of a region of interest (ROI) and dose calculation of target region and organ at risk were evaluated, in order to validate the accuracy automated treatment planning verification system. Results: The difference of volume for Pinnacle to M3D was less than results for Eclipse to M3D in ROI, the biggest difference was 0.22± 0.69%, 3.5±1.89% for Pinnacle and Eclipse respectively. M3D showed slightly better agreement in dose of target and organ at risk compared with TPS. But after recalculating plans by M3D, dose difference for Pinnacle was less than Eclipse on average, results were within 3%. Conclusion: The method of utilizing the automated treatment planning system to validate the accuracy of plans is convenientbut the scope of differences still need more clinical patient cases to determine. At present, it should be used as a secondary check tool to improve safety in the clinical treatment planning.

  2. Regulations, Codes, and Standards (RCS) Template for California Hydrogen Dispensing Stations

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, C.; Blake, C.; Burgess, R.; Buttner, W.; Post, M.

    2012-11-01

    This report explains the Regulations, Codes, and Standards (RCS) requirements for hydrogen dispensing stations in the State of California. The reports shows the basic components of a hydrogen dispensing station in a simple schematic drawing; the permits and approvals that would typically be required for the construction and operation of a hydrogen dispensing station; and a basic permit that might be employed by an Authority Having Jurisdiction (AHJ).

  3. Development of an Automatic Dispensing System for Traditional Chinese Herbs

    Directory of Open Access Journals (Sweden)

    Chi-Ying Lin

    2017-01-01

    Full Text Available The gathering of ingredients for decoctions of traditional Chinese herbs still relies on manual dispensation, due to the irregular shape of many items and inconsistencies in weights. In this study, we developed an automatic dispensing system for Chinese herbal decoctions with the aim of reducing manpower costs and the risk of mistakes. We employed machine vision in conjunction with a robot manipulator to facilitate the grasping of ingredients. The name and formulation of the decoction are input via a human-computer interface, and the dispensing of multiple medicine packets is performed automatically. An off-line least-squared curve fitting method was used to calculate the amount of material grasped by the claws and thereby improve system efficiency as well as the accuracy of individual dosages. Experiments on the dispensing of actual ingredients demonstrate the feasibility of the proposed system.

  4. Hand sanitizer dispensers and associated hospital-acquired infections: friend or fomite?

    Science.gov (United States)

    Eiref, Simon D; Leitman, I Michael; Riley, William

    2012-06-01

    Waterless alcohol-based hand sanitizers are an increasingly popular method of hand hygiene and help prevent hospital-acquired infection (HAI). Whether hand sanitizer dispensers (HSDs) may themselves harbor pathogens or act as fomites has not been reported. All HSDs in the surgical intensive care unit of an urban teaching hospital were cultured at three sites: The dispenser lever, the rear underside, and the area surrounding the dispensing nozzle. All HSDs yielded one or more bacterial species, including commensal skin flora and enteric gram-negative bacilli. Colonization was greatest on the lever, where there is direct hand contact. Hand sanitizer dispensers can become contaminated with pathogens that cause HAI and thus are potential fomites.

  5. Drug-dispensing errors in the hospital pharmacy Erros de dispensação de medicamentos em farmácia hospitalar

    Directory of Open Access Journals (Sweden)

    Tânia Azevedo Anacleto

    2007-01-01

    Full Text Available OBJECTIVE: To determine the dispensing error rate and to identify factors associated with them, and to propose prevention actions. METHODS: A cross-sectional study focusing on the occurrence of dispensing errors in a general hospital in Belo Horizonte that uses a mixed system (a combination of multidose and unit dose systems of collective and individualized dosing. RESULTS: A total of 422 prescription order forms were analyzed, registering 81.8% with at least 1 dispensing error. Opportunities for errors were higher in the pretyped prescription order forms (odds ratio = 4.5; P OBJETIVO: Determinar a taxa de erros de dispensação e identificar fatores associados, propondo ações de prevenção. MÉTODOS: Estudo transversal investigou-se a ocorrência de erros de dispensação em um hospital geral de Belo Horizonte que emprega um sistema misto de dose coletiva e individualizada. RESULTADOS: Foram analisadas 422 prescrições, registrando em 81,8% destas pelo menos um erro de dispensação. Oportunidades de erros foram maiores nas prescrições pré-digitadas (Odds Ratio=4,5; p<0,001, naquelas com nove ou mais medicamentos (Odds Ratio=4,0; p<0,001 e com os injetáveis (Odds Ratio=5,0; p<0,001. Uma das equipes de profissionais apresentou maior chance de erros (Odds Ratio=2,0; p=0,02. A análise multivariada ratifica estes resultados. CONCLUSÃO: Conclui-se que o sistema de dispensação da farmácia apresenta muitas falhas latentes e poucas defesas, com diversas condições que predispõe a ocorrência de erros, contribuindo para a elevada taxa registrada.

  6. SU-E-T-427: Feasibility Study for Evaluation of IMRT Dose Distribution Using Geant4-Based Automated Algorithms

    International Nuclear Information System (INIS)

    Choi, H; Shin, W; Testa, M; Min, C; Kim, J

    2015-01-01

    Purpose: For intensity-modulated radiation therapy (IMRT) treatment planning validation using Monte Carlo (MC) simulations, a precise and automated procedure is necessary to evaluate the patient dose distribution. The aim of this study is to develop an automated algorithm for IMRT simulations using DICOM files and to evaluate the patient dose based on 4D simulation using the Geant4 MC toolkit. Methods: The head of a clinical linac (Varian Clinac 2300 IX) was modeled in Geant4 along with particular components such as the flattening filter and the multi-leaf collimator (MLC). Patient information and the position of the MLC were imported from the DICOM-RT interface. For each position of the MLC, a step- and-shoot technique was adopted. PDDs and lateral profiles were simulated in a water phantom (50×50×40 cm 3 ) and compared to measurement data. We used a lung phantom and MC-dose calculations were compared to the clinical treatment planning used at the Seoul National University Hospital. Results: In order to reproduce the measurement data, we tuned three free parameters: mean and standard deviation of the primary electron beam energy and the beam spot size. These parameters for 6 MV were found to be 5.6 MeV, 0.2378 MeV and 1 mm FWHM respectively. The average dose difference between measurements and simulations was less than 2% for PDDs and radial profiles. The lung phantom study showed fairly good agreement between MC and planning dose despite some unavoidable statistical fluctuation. Conclusion: The current feasibility study using the lung phantom shows the potential for IMRT dose validation using 4D MC simulations using Geant4 tool kits. This research was supported by Korea Institute of Nuclear safety and Development of Measurement Standards for Medical Radiation funded by Korea research Institute of Standards and Science. (KRISS-2015-15011032)

  7. Do Pregnant Women Report Use of Dispensed Medications?

    DEFF Research Database (Denmark)

    Olesen, Charlotte; Søndergaard, Charlotte; Thrane, Nana

    2001-01-01

    Surveillance of drug safety in pregnancy often draws on administrative prescription registries. Noncompliance in the use of prescribed medication may be frequent among pregnant women owing to their fear of fetotoxic side effects. To estimate compliance in the use of prescription drugs dispensed...... during pregnancy, we compared prescription data from the North Jutland Prescription Database with information on drug use provided by pregnant women to the Danish National Birth Cohort (DNBC), which is a health interview survey. We used the North Jutland Prescription Database to identify all prescription...... drugs dispensed during pregnancy for the 2,041 women who were enrolled in the DNBC in the County of North Jutland, Denmark. Compliance was defined as the probability of reporting drug use in DNBC after purchasing a dispensed prescription drug. The overall compliance to drugs purchased within 120 days...

  8. The 340B discount program: outpatient prescription dispensing patterns through contract pharmacies in 2012.

    Science.gov (United States)

    Clark, Bobby L; Hou, John; Chou, Chia-Hung; Huang, Elbert S; Conti, Rena

    2014-11-01

    Section 340B of the Public Health Service Act provides qualified organizations serving vulnerable populations with deep discounts for some outpatient medications. A 2010 regulatory change widely expanded the 340B program's reach, allowing these organizations to contract with retail pharmacies to dispense medications for eligible patients. Little is known about which medications are dispensed by contract pharmacies under the expanded program. We provide the first comparison of 340B prescriptions and all prescriptions dispensed in contract pharmacies. We used 2012 data from Walgreens, the national leader in 340B contract pharmacies. Medications used to treat chronic conditions such as diabetes, high cholesterol levels, asthma, and depression accounted for an overwhelming majority of all prescriptions dispensed at Walgreens as part of the 340B program. A higher percentage of antiretrovirals used to treat HIV/AIDS were dispensed through 340B prescriptions than through all prescriptions dispensed at Walgreens. The majority of 340B prescriptions dispensed at Walgreens originated at tuberculosis clinics, consolidated health centers, disproportionate-share hospitals, and Ryan White clinics. Our results suggest that 340B contract pharmacies dispense medications used to treat Americans' chronic disease burden and disproportionately dispense medications used by key vulnerable populations targeted by the program. Project HOPE—The People-to-People Health Foundation, Inc.

  9. Automated image enhancement using power law transformations

    Indian Academy of Sciences (India)

    We propose a scheme for automating power law transformations which are used for image enhancement. The scheme we propose does not require the user to choose the exponent in the power law transformation. This method works well for images having poor contrast, especially to those images in which the peaks ...

  10. Pharmacists' role in opioid overdose: Kentucky pharmacists' willingness to participate in naloxone dispensing.

    Science.gov (United States)

    Freeman, Patricia R; Goodin, Amie; Troske, SuZanne; Strahl, Audra; Fallin, Amanda; Green, Traci C

    To assess pharmacists' willingness to initiate the dispensing of naloxone. As of 2015, Kentucky law permits certified pharmacists to dispense naloxone under a physician-approved protocol. Electronic survey (e-mail) gauging perception of pharmacists' role in opioid overdose and attitudes toward, and barriers to, naloxone dispensing. All Kentucky pharmacists with active licenses in 2015. Ordinal logistic regression was used to estimate the impact of pharmacist characteristics and attitudes on willingness to initiate naloxone dispensing, where the dependent variable was operationalized as a Likert-type question on a scale of 1 (not at all willing) to 6 (very willing). Of 4699 practicing Kentucky pharmacists, 1282 responded, of which 834 were community practitioners (response rate 27.3%). Pharmacists reported varying willingness to initiate naloxone dispensing, with 37.3% very willing (score 5 or 6) and 27.9% not willing (score 1 or 2). However, a majority of pharmacists reported willingness to dispense naloxone with a valid prescription (54.0%, score 5 or 6). Women pharmacists were 1.3 times more likely than men to be willing to initiate naloxone dispensing (95% confidence interval [CI] 1.0-1.6). Those who reported confidence in identifying individuals at risk for overdose were 1.2 times more likely to initiate dispensing, and those who reported confidence in ability to educate patients about overdose were 1.6 times more likely to express willingness to initiate naloxone dispensing (95% CIs, respectively, 1.0-1.3 and 1.4-1.8). Community pharmacists reported barriers to naloxone access at higher rates than pharmacists from other practice settings. Kentucky pharmacists are divided in their willingness to initiate naloxone dispensing; however, those who are confident in their ability to identify overdose risks are more willing. Increasing pharmacist confidence through appropriately designed education programs could facilitate pharmacist participation in naloxone

  11. Automated Inadvertent Intruder Application

    International Nuclear Information System (INIS)

    Koffman, Larry D.; Lee, Patricia L.; Cook, James R.; Wilhite, Elmer L.

    2008-01-01

    The Environmental Analysis and Performance Modeling group of Savannah River National Laboratory (SRNL) conducts performance assessments of the Savannah River Site (SRS) low-level waste facilities to meet the requirements of DOE Order 435.1. These performance assessments, which result in limits on the amounts of radiological substances that can be placed in the waste disposal facilities, consider numerous potential exposure pathways that could occur in the future. One set of exposure scenarios, known as inadvertent intruder analysis, considers the impact on hypothetical individuals who are assumed to inadvertently intrude onto the waste disposal site. Inadvertent intruder analysis considers three distinct scenarios for exposure referred to as the agriculture scenario, the resident scenario, and the post-drilling scenario. Each of these scenarios has specific exposure pathways that contribute to the overall dose for the scenario. For the inadvertent intruder analysis, the calculation of dose for the exposure pathways is a relatively straightforward algebraic calculation that utilizes dose conversion factors. Prior to 2004, these calculations were performed using an Excel spreadsheet. However, design checks of the spreadsheet calculations revealed that errors could be introduced inadvertently when copying spreadsheet formulas cell by cell and finding these errors was tedious and time consuming. This weakness led to the specification of functional requirements to create a software application that would automate the calculations for inadvertent intruder analysis using a controlled source of input parameters. This software application, named the Automated Inadvertent Intruder Application, has undergone rigorous testing of the internal calculations and meets software QA requirements. The Automated Inadvertent Intruder Application was intended to replace the previous spreadsheet analyses with an automated application that was verified to produce the same calculations and

  12. Separation of prescribing and dispensing in Malaysia: the history and challenges.

    Science.gov (United States)

    Tiong, John Jeh Lung; Mai, Chun Wai; Gan, Pou Wee; Johnson, James; Mak, Vivienne Sook Li

    2016-08-01

    This article serves as an update to the work by Shafie et al. (2012) which previously reviewed the benefits of policies separating prescribing and dispensing in various countries to advocate its implementation in Malaysia. This article seeks to strengthen the argument by highlighting not only the weaknesses of the Malaysian health care system from the historical, professional and economic viewpoints but also the shortcomings of both medical and pharmacy professions in the absence of separation of dispensing. It also provides a detailed insight into the ongoing initiatives taken to consolidate the role of pharmacists in the health care system in the advent of separation of dispensing. Under the two tier system in Malaysia at present, the separation of prescribing and dispensing is implemented only in government hospitals. The absence of this separation in the private practices has led to possible profit-oriented medical and pharmacy practices which hinder safe and cost-effective delivery of health services. The call for separation of dispensing has gained traction over the years despite various hurdles ranging from the formidable resistance from the medical fraternity to the public's scepticism towards the new policy. With historical testament and present evidence pointing towards the merits of a system in which doctors prescribe and pharmacists dispense, the implementation of this health care model is justified. © 2016 The Authors. IJPP © 2016 Royal Pharmaceutical Society.

  13. Feasibility study of a biocompatible pneumatic dispensing system using mouse 3T3-J2 fibroblasts

    Science.gov (United States)

    Lee, Sangmin; Kim, Hojin; Kim, Joonwon

    2017-12-01

    This paper presents results for dispensing living cells using a pneumatic dispensing system to verify the feasibility of using this system to fabricate biomaterials. Living cells (i.e., mouse 3T3-J2 fibroblast) were dispensed with different dispensing pressures in order to evaluate the effect of dispensing process on cell viability and proliferation. Based on the results of a live-dead assay, more than 80% of cell viability has been confirmed which was reasonably similar to that in the control group. Furthermore, measurement of cell metabolic activity after dispensing confirmed that the dispensed cell proliferated at a rate comparable to that of the control group. These results demonstrate that the pneumatic dispensing system is a promising tool for fabrication of biomaterials.

  14. Cloud-based CT dose monitoring using the DICOM-structured report. Fully automated analysis in regard to national diagnostic reference levels

    International Nuclear Information System (INIS)

    Boos, J.; Rubbert, C.; Heusch, P.; Lanzman, R.S.; Aissa, J.; Antoch, G.; Kroepil, P.

    2016-01-01

    To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). Materials and Methods: We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDI vol ) and dose length product (DLP). Results: Data of 36 523 examinations (131 527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDI vol and DLP were 51.3 % and 52.8 % of the national DRLs, respectively. CTDI vol and DLP reached 43.8 % and 43.1 % for abdominal CT (n = 10 590), 66.6 % and 69.6 % for cranial CT (n = 16 098) and 37.8 % and 44.0 % for chest CT (n = 10 387) of the compared national DRLs, respectively. Overall, the CTDI vol exceeded national DRLs in 1.9 % of the examinations, while the DLP exceeded national DRLs in 2.9 % of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50 % of the DRLs. Conclusion: The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50 % of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments.

  15. Poorly processed reusable surface disinfection tissue dispensers may be a source of infection.

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Jesse, Katrin; von Baum, Heike; Ostermeyer, Christiane

    2014-01-21

    Reusable surface disinfectant tissue dispensers are used in hospitals in many countries because they allow immediate access to pre-soaked tissues for targeted surface decontamination. On the other hand disinfectant solutions with some active ingredients may get contaminated and cause outbreaks. We determined the frequency of contaminated surface disinfectant solutions in reusable dispensers and the ability of isolates to multiply in different formulations. Reusable tissue dispensers with different surface disinfectants were randomly collected from healthcare facilities. Solutions were investigated for bacterial contamination. The efficacy of two surface disinfectants was determined in suspension tests against two isolated species directly from a contaminated solution or after 5 passages without selection pressure in triplicate. Freshly prepared use solutions were contaminated to determine survival of isolates. 66 dispensers containing disinfectant solutions with surface-active ingredients were collected in 15 healthcare facilities. 28 dispensers from nine healthcare facilities were contaminated with approximately 107 cells per mL of Achromobacter species 3 (9 hospitals), Achromobacter xylosoxidans or Serratia marcescens (1 hospital each). In none of the hospitals dispenser processing had been adequately performed. Isolates regained susceptibility to the disinfectants after five passages without selection pressure but were still able to multiply in different formulations from different manufacturers at room temperature within 7 days. Neglecting adequate processing of surface disinfectant dispensers has contributed to frequent and heavy contamination of use-solutions based on surface active ingredients. Tissue dispenser processing should be taken seriously in clinical practice.

  16. Pharmacy Automation in Navy Medicine: A Study of Naval Medical Center San Diego

    Science.gov (United States)

    2015-09-01

    Whittlesea, C. (2013). The impact of automation on workload and dispensing errors in a hospital pharmacy . International Journal of Pharmacy Practice , 21...Welsh NHS hospitals. International Journal of Pharmacy Practice , 16, 175–188. Lin, A. C., Huang, Y.-C., Punches, G., & Chen, Y. (2007). Effect of a...expectations of outpatient pharmacy services in a teaching hospital. International Journal of Pharmacy Medicine , 5(3), 128–132. 79 INITIAL

  17. Dispensing processes impact apparent biological activity as determined by computational and statistical analyses.

    Directory of Open Access Journals (Sweden)

    Sean Ekins

    Full Text Available Dispensing and dilution processes may profoundly influence estimates of biological activity of compounds. Published data show Ephrin type-B receptor 4 IC50 values obtained via tip-based serial dilution and dispensing versus acoustic dispensing with direct dilution differ by orders of magnitude with no correlation or ranking of datasets. We generated computational 3D pharmacophores based on data derived by both acoustic and tip-based transfer. The computed pharmacophores differ significantly depending upon dispensing and dilution methods. The acoustic dispensing-derived pharmacophore correctly identified active compounds in a subsequent test set where the tip-based method failed. Data from acoustic dispensing generates a pharmacophore containing two hydrophobic features, one hydrogen bond donor and one hydrogen bond acceptor. This is consistent with X-ray crystallography studies of ligand-protein interactions and automatically generated pharmacophores derived from this structural data. In contrast, the tip-based data suggest a pharmacophore with two hydrogen bond acceptors, one hydrogen bond donor and no hydrophobic features. This pharmacophore is inconsistent with the X-ray crystallographic studies and automatically generated pharmacophores. In short, traditional dispensing processes are another important source of error in high-throughput screening that impacts computational and statistical analyses. These findings have far-reaching implications in biological research.

  18. Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers

    International Nuclear Information System (INIS)

    Park, Jun Chul; Pyo, Sung Jae

    2012-01-01

    The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like 99m Tc-HDP and 18 F-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety

  19. Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose

    International Nuclear Information System (INIS)

    Scholtz, Jan-Erik; Wichmann, Julian L.; Huesers, Kristina; Albrecht, Moritz H.; Beeres, Martin; Bauer, Ralf W.; Vogl, Thomas J.; Bodelle, Boris

    2016-01-01

    To evaluate image quality and radiation dose in third-generation dual-source computed tomography (DSCT) of the neck using automated tube voltage adaptation (TVA) with advanced modelled iterative reconstruction (ADMIRE) algorithm. One hundred and sixteen patients were retrospectively evaluated. Group A (n = 59) was examined on second-generation DSCT with automated TVA and filtered back projection. Group B (n = 57) was examined on a third-generation DSCT with automated TVA and ADMIRE. Age, body diameter, attenuation of several anatomic structures, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), radiation dose (CTDI vol ) and size-specific dose estimates (SSDE) were assessed. Diagnostic acceptability was rated by three readers. Age (p = 0.87) and body diameter (p = 0.075) did not differ significantly. Tube voltage in Group A was set automatically to 100 kV for all patients (n = 59), and to 70 kV (n = 2), 80 kV (n = 5), and 90 kV (n = 50) in Group B. Noise was reduced and CNR was increased significantly (p < 0.001). Diagnostic acceptability was rated high in both groups, with better ratings in Group B (p < 0.001). SSDE was reduced by 34 % in Group B (20.38 ± 1.63 mGy vs. 13.04 ± 1.50 mGy, p < 0.001). Combination of automated TVA and ADMIRE in neck CT using third-generation DSCT results in a substantial radiation dose reduction with low noise and increased CNR. (orig.)

  20. Application of automated blind for daylighting in tropical region

    International Nuclear Information System (INIS)

    Chaiwiwatworakul, Pipat; Chirarattananon, Surapong; Rakkwamsuk, Pattana

    2009-01-01

    This paper reports an experimental and simulation study on application of automated Venetian blind for daylighting in tropical climate. A horizontal blind system operating automatically under programmed control was constructed and integrated onto the glazed windows to form a window system with an automated blind in a room of a laboratory building. A dimming controller was also integrated to the lighting system of the room. Different operation schemes of the window system were devised and tested in the attempt to maximize energy savings while maintaining the quality of the visual environment in the room. Intensive measurement of illuminance of the interior space was undertaken during the experiments. A methodology for calculation of interior daylight illuminance and associated glare corresponding to the configurations of the experiments was adopted. The method was coded into a computer program. Results of calculation from the program agree well with those from experiments for all the schemes of operation conducted. The program was used to simulate the situation when each scheme of operation was implemented for a whole year. It was found that such window system with automated blind enabled energy savings of 80%, but a more sophisticated scheme also helped maintain the interior visual quality at high level.

  1. A simple automated system for appetitive conditioning of zebrafish in their home tanks.

    Science.gov (United States)

    Doyle, Jillian M; Merovitch, Neil; Wyeth, Russell C; Stoyek, Matthew R; Schmidt, Michael; Wilfart, Florentin; Fine, Alan; Croll, Roger P

    2017-01-15

    We describe here an automated apparatus that permits rapid conditioning paradigms for zebrafish. Arduino microprocessors were used to control the delivery of auditory or visual stimuli to groups of adult or juvenile zebrafish in their home tanks in a conventional zebrafish facility. An automatic feeder dispensed precise amounts of food immediately after the conditioned stimuli, or at variable delays for controls. Responses were recorded using inexpensive cameras, with the video sequences analysed with ImageJ or Matlab. Fish showed significant conditioned responses in as few as 5 trials, learning that the conditioned stimulus was a predictor of food presentation at the water surface and at the end of the tank where the food was dispensed. Memories of these conditioned associations persisted for at least 2days after training when fish were tested either as groups or as individuals. Control fish, for which the auditory or visual stimuli were specifically unpaired with food, showed no comparable responses. This simple, low-cost, automated system permits scalable conditioning of zebrafish with minimal human intervention, greatly reducing both variability and labour-intensiveness. It will be useful for studies of the neural basis of learning and memory, and for high-throughput screening of compounds modifying those processes. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    International Nuclear Information System (INIS)

    Young, S; Lo, P; Hoffman, J; Wahi-Anwar, M; Brown, M; McNitt-Gray, M; Noo, F

    2016-01-01

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT_wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range

  3. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Young, S; Lo, P; Hoffman, J; Wahi-Anwar, M; Brown, M; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States); Noo, F [University of Utah, Salt Lake City, UT (United States)

    2016-06-15

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT-wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range

  4. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor

    International Nuclear Information System (INIS)

    Polo-López, M.I.; Fernández-Ibáñez, P.; Ubomba-Jaswa, E.; Navntoft, C.; García-Fernández, I.; Dunlop, P.S.M.; Schmid, M.; Byrne, J.A.

    2011-01-01

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input.

  5. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor

    Energy Technology Data Exchange (ETDEWEB)

    Polo-Lopez, M.I., E-mail: mpolo@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Fernandez-Ibanez, P., E-mail: pilar.fernandez@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Ubomba-Jaswa, E., E-mail: euniceubombajaswa@yahoo.com [Natural Resources and the Environment, CSIR, PO Box 395, Pretoria (South Africa); Navntoft, C., E-mail: christian.navntoft@solarmate.com.ar [Instituto de Investigacion e Ingenieria Ambiental, Universidad Nacional de San Martin (3iA-UNSAM), Peatonal Belgrano 3563, B1650ANQ San Martin (Argentina); Universidad Tecnologica Nacional - Facultad Regional Buenos Aires - Departamento de Ingenieria Civil - Laboratorio de Estudios sobre Energia Solar, (UTN-FRBA-LESES), Mozart 2300, (1407) Ciudad Autonoma de Buenos Aires, Republica Argentina (Argentina); Garcia-Fernandez, I., E-mail: irene.garcia@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Dunlop, P.S.M., E-mail: psm.dunlop@ulster.ac.uk [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); Schmid, M. [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); Byrne, J.A., E-mail: j.byrne@ulster.ac.uk [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); and others

    2011-11-30

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input.

  6. Impact of automated dispensing cabinets on medication selection and preparation error rates in an emergency department: a prospective and direct observational before-and-after study.

    Science.gov (United States)

    Fanning, Laura; Jones, Nick; Manias, Elizabeth

    2016-04-01

    The implementation of automated dispensing cabinets (ADCs) in healthcare facilities appears to be increasing, in particular within Australian hospital emergency departments (EDs). While the investment in ADCs is on the increase, no studies have specifically investigated the impacts of ADCs on medication selection and preparation error rates in EDs. Our aim was to assess the impact of ADCs on medication selection and preparation error rates in an ED of a tertiary teaching hospital. Pre intervention and post intervention study involving direct observations of nurses completing medication selection and preparation activities before and after the implementation of ADCs in the original and new emergency departments within a 377-bed tertiary teaching hospital in Australia. Medication selection and preparation error rates were calculated and compared between these two periods. Secondary end points included the impact on medication error type and severity. A total of 2087 medication selection and preparations were observed among 808 patients pre and post intervention. Implementation of ADCs in the new ED resulted in a 64.7% (1.96% versus 0.69%, respectively, P = 0.017) reduction in medication selection and preparation errors. All medication error types were reduced in the post intervention study period. There was an insignificant impact on medication error severity as all errors detected were categorised as minor. The implementation of ADCs could reduce medication selection and preparation errors and improve medication safety in an ED setting. © 2015 John Wiley & Sons, Ltd.

  7. The impact of automation on pharmacy staff experience of workplace stressors.

    Science.gov (United States)

    James, K Lynette; Barlow, Dave; Bithell, Anne; Hiom, Sarah; Lord, Sue; Oakley, Pat; Pollard, Mike; Roberts, Dave; Way, Cheryl; Whittlesea, Cate

    2013-04-01

    Determine the effect of installing an original pack automated dispensing system (ADS) on staff experience of occupational stressors. Pharmacy staff in a National Health Service hospital in Wales, UK, were administered an anonymous occupational stressor questionnaire pre- (n = 45) and post-automation (n = 32). Survey responses pre- and post-automation were compared using Mann-Whitney U test. Statistical significance was P ≤ 0.05. Four focus groups were conducted (two groups of accredited checking technicians (ACTs) (group 1: n = 4; group 2: n = 6), one group of pharmacists (n = 17), and one group of technicians (n = 4) post-automation to explore staff experiences of occupational stressors. Focus group transcripts were analysed according to framework analysis. Survey response rate pre-automation was 78% (n = 35) and 49% (n = 16) post-automation. Automation had a positive impact on staff experience of stress (P = 0.023), illogical workload allocation (P = 0.004) and work-life balance (P = 0.05). All focus-group participants reported that automation had created a spacious working environment. Pharmacists and ACTs reported that automation had enabled the expansion of their roles. Technicians felt like 'production-line workers.' Robot malfunction was a source of stress. The findings suggest that automation had a positive impact on staff experience of stressors, improving working conditions and workload. Technicians reported that ADS devalued their skills. When installing ADS, pharmacy managers must consider the impact of automation on staff. Strategies to reduce stressors associated with automation include rotating staff activities and role expansions. © 2012 The Authors. IJPP © 2012 Royal Pharmaceutical Society.

  8. Towards Automated Reasoning on ORM Schemes

    Science.gov (United States)

    Jarrar, Mustafa

    The goal of this article is to formalize Object Role Modeling (ORM) using the {DLR} description logic. This would enable automated reasoning on the formal properties of ORM diagrams, such as detecting constraint contradictions and implications. In addition, the expressive, methodological, and graphical capabilities of ORM make it a good candidate for use as a graphical notation for most description logic languages. In this way, industrial experts who are not IT savvy will still be able to build and view axiomatized theories (such as ontologies, business rules, etc.) without needing to know the logic or reasoning foundations underpinning them. Our formalization in this paper is structured as 29 formalization rules, that map all ORM primitives and constraints into {DLR}, and 2 exceptions of complex cases. To this end, we illustrate the implementation of our formalization as an extension to DogmaModeler, which automatically maps ORM into DIG and uses Racer as a background reasoning engine to reason about ORM diagrams.

  9. Fully automated bone mineral density assessment from low-dose chest CT

    Science.gov (United States)

    Liu, Shuang; Gonzalez, Jessica; Zulueta, Javier; de-Torres, Juan P.; Yankelevitz, David F.; Henschke, Claudia I.; Reeves, Anthony P.

    2018-02-01

    A fully automated system is presented for bone mineral density (BMD) assessment from low-dose chest CT (LDCT). BMD assessment is central in the diagnosis and follow-up therapy monitoring of osteoporosis, which is characterized by low bone density and is estimated to affect 12.3 million US population aged 50 years or older, creating tremendous social and economic burdens. BMD assessment from DXA scans (BMDDXA) is currently the most widely used and gold standard technique for the diagnosis of osteoporosis and bone fracture risk estimation. With the recent large-scale implementation of annual lung cancer screening using LDCT, great potential emerges for the concurrent opportunistic osteoporosis screening. In the presented BMDCT assessment system, each vertebral body is first segmented and labeled with its anatomical name. Various 3D region of interest (ROI) inside the vertebral body are then explored for BMDCT measurements at different vertebral levels. The system was validated using 76 pairs of DXA and LDCT scans of the same subject. Average BMDDXA of L1-L4 was used as the reference standard. Statistically significant (p-value correlation is obtained between BMDDXA and BMDCT at all vertebral levels (T1 - L2). A Pearson correlation of 0.857 was achieved between BMDDXA and average BMDCT of T9-T11 by using a 3D ROI taking into account of both trabecular and cortical bone tissue. These encouraging results demonstrate the feasibility of fully automated quantitative BMD assessment and the potential of opportunistic osteoporosis screening with concurrent lung cancer screening using LDCT.

  10. Bacterial hand contamination and transfer after use of contaminated bulk-soap-refillable dispensers.

    Science.gov (United States)

    Zapka, Carrie A; Campbell, Esther J; Maxwell, Sheri L; Gerba, Charles P; Dolan, Michael J; Arbogast, James W; Macinga, David R

    2011-05-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log(10) CFU/ml of Serratia marcescens, an average of 5.28 log(10) CFU remained on each hand after washing, and 2.23 log(10) CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log(10) CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log(10) CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log(10) CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log(10) CFU; P soap (P soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings.

  11. SYSTEM OF PRECISE DOSING OF COAGULANT IN THE PULVERIZING AERATOR POWERED BY WIND USING FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    Andrzej Osuch

    2017-06-01

    Full Text Available One of the methods used to support land restoration lakes is the method of pulverizing aeration. Use of aerators powered exclusively by wind improves the condition of reservoirs, while not compromising the environment. The pulverizing aeration process drive is windy on the water aeration zone near bottom, while removing harmful gases anaerobic metabolism. Aerators of this type due to the unique method of operation also enable dosing of inactivation coagulants with oxygenated water to the depths of the lake. Mileage coagulant dosing can be made dependent on the speed of the wind, which has an impact on the performance of his work, because with the increase of wind speed dispensing valve coagulants should be stronger open. One of the methods for assessing the state of lakes is to measure water transparency. The softer visibility, the most likely state of the water is better. Dosage of coagulant so you can make the transparency of the water. Similarly, with increasing transparency water dispensing valve should be more covered up. Control of the drain valve dispenser coagulant can be simultaneously dependent on two factors. The study was designed method of control drain valve dispenser coagulant using fuzzy inference.

  12. A frequency conversion mode for dispenser in the service station based on flow rate signal

    International Nuclear Information System (INIS)

    Liu, Y J; Tang, D; Huang, J B; Liu, J; Jia, P F

    2012-01-01

    Dispenser is an integrated fuel transport and measurement system at the service station. In this paper, we developed a frequency conversion mode for the dispenser, based on the flow rate signal which is obtained from the converter measuring flow capacity. After introducing the frequency conversion mode to dispenser, we obtained that pump rotates at a high speed when fuelled with high flow rate, and it rotates at a low speed when fuelled with low flow rate. This makes the fuel dispenser more energy-efficient and controllable. We also did some valve optimizations on the dispenser and developed a new control mode for preset refuelling based on the frequency conversion mode, Experimental and theoretical studies have shown that the new dispenser not only can meet the national standards, but also performs better than the ordinary one especially in preset refuelling.

  13. Control and automation systems

    International Nuclear Information System (INIS)

    Schmidt, R.; Zillich, H.

    1986-01-01

    A survey is given of the development of control and automation systems for energy uses. General remarks about control and automation schemes are followed by a description of modern process control systems along with process control processes as such. After discussing the particular process control requirements of nuclear power plants the paper deals with the reliability and availability of process control systems and refers to computerized simulation processes. The subsequent paragraphs are dedicated to descriptions of the operating floor, ergonomic conditions, existing systems, flue gas desulfurization systems, the electromagnetic influences on digital circuits as well as of light wave uses. (HAG) [de

  14. High-Dose-Rate Brachytherapy Boost for Prostate Cancer: Comparison of Two Different Fractionation Schemes

    International Nuclear Information System (INIS)

    Kaprealian, Tania; Weinberg, Vivian; Speight, Joycelyn L.; Gottschalk, Alexander R.; Roach, Mack; Shinohara, Katsuto; Hsu, I.-Chow

    2012-01-01

    Purpose: This is a retrospective study comparing our experience with high-dose-rate (HDR) brachytherapy boost for prostate cancer, using two different fractionation schemes, 600 cGy × 3 fractions (patient group 1) and 950 cGy × 2 fractions (patient group 2). Methods and Materials: A total of 165 patients were treated for prostate cancer using external beam radiation therapy up to a dose of 45 Gy, followed by an HDR brachytherapy prostate radiation boost. Between July 1997 and Nov 1999, 64 patients were treated with an HDR boost of 600 cGy × 3 fractions; and between June 2000 and Nov 2005, 101 patients were treated with an HDR boost of 950 cGy × 2 fractions. All but 9 patients had at least one of the following risk features: pretreatment prostate-specific antigen (PSA) level >10, a Gleason score ≥7, and/or clinical stage T3 disease. Results: Median follow-up was 105 months for group 1 and 43 months for group 2. Patients in group 2 had a greater number of high-risk features than group 1 (p = 0.02). Adjusted for comparable follow-up, there was no difference in biochemical no-evidence-of-disease (bNED) rate between the two fractionation scheme approaches, with 5-year Kaplan-Meier estimates of 93.5% in group 1 and 87.3% in group 2 (p = 0.19). The 5-year estimates of progression-free survival were 86% for group 1 and 83% for group 2 (p = 0.53). Among high-risk patients, there were no differences in bNED or PFS rate due to fractionation. Conclusions: Results were excellent for both groups. Adjusted for comparable follow-up, no differences were found between groups.

  15. Dispensing apparatus for use in a cued food delivery task.

    Science.gov (United States)

    Deweese, Menton M; Claiborne, Kimberly N; Ng, Jennifer; Dirba, Danika D; Stewart, Hannah L; Schembre, Susan M; Versace, Francesco

    2015-01-01

    Neurobiological models of obesity postulate that obese individuals have difficulty regulating food intake partly because they attribute excessive salience to stimuli signaling food availability. Typically, human studies that investigate the relationship between brain responses to food-related stimuli and obesity present food cues without subsequent delivery of food. However, in order to identify the brain correlates of cue reactivity, we must record brain responses to food-related cues signaling food availability. Therefore, we have developed a dispensing apparatus for use in a cued-food delivery task in which event-related potentials (ERPs) to food-related images predicting food delivery and images not predicting food delivery can be recorded. Here, we describe a method where:•The experimental apparatus dispenses an edible item (i.e., a chocolate candy) which may or may not be eaten, or a non-edible control item (e.g., a plastic bead).•Deposit boxes are available to store uneaten candies and the non-edible control items.•The dispensing mechanism is capable of recording the exact timestamp when each delivery event occurs (e.g., release from the dispenser, arrival in the receptacle, storage in the deposit box).

  16. D-MSR: A Distributed Network Management Scheme for Real-Time Monitoring and Process Control Applications in Wireless Industrial Automation

    Science.gov (United States)

    Zand, Pouria; Dilo, Arta; Havinga, Paul

    2013-01-01

    Current wireless technologies for industrial applications, such as WirelessHART and ISA100.11a, use a centralized management approach where a central network manager handles the requirements of the static network. However, such a centralized approach has several drawbacks. For example, it cannot cope with dynamicity/disturbance in large-scale networks in a real-time manner and it incurs a high communication overhead and latency for exchanging management traffic. In this paper, we therefore propose a distributed network management scheme, D-MSR. It enables the network devices to join the network, schedule their communications, establish end-to-end connections by reserving the communication resources for addressing real-time requirements, and cope with network dynamicity (e.g., node/edge failures) in a distributed manner. According to our knowledge, this is the first distributed management scheme based on IEEE 802.15.4e standard, which guides the nodes in different phases from joining until publishing their sensor data in the network. We demonstrate via simulation that D-MSR can address real-time and reliable communication as well as the high throughput requirements of industrial automation wireless networks, while also achieving higher efficiency in network management than WirelessHART, in terms of delay and overhead. PMID:23807687

  17. D-MSR: a distributed network management scheme for real-time monitoring and process control applications in wireless industrial automation.

    Science.gov (United States)

    Zand, Pouria; Dilo, Arta; Havinga, Paul

    2013-06-27

    Current wireless technologies for industrial applications, such as WirelessHART and ISA100.11a, use a centralized management approach where a central network manager handles the requirements of the static network. However, such a centralized approach has several drawbacks. For example, it cannot cope with dynamicity/disturbance in large-scale networks in a real-time manner and it incurs a high communication overhead and latency for exchanging management traffic. In this paper, we therefore propose a distributed network management scheme, D-MSR. It enables the network devices to join the network, schedule their communications, establish end-to-end connections by reserving the communication resources for addressing real-time requirements, and cope with network dynamicity (e.g., node/edge failures) in a distributed manner. According to our knowledge, this is the first distributed management scheme based on IEEE 802.15.4e standard, which guides the nodes in different phases from joining until publishing their sensor data in the network. We demonstrate via simulation that D-MSR can address real-time and reliable communication as well as the high throughput requirements of industrial automation wireless networks, while also achieving higher efficiency in network management than WirelessHART, in terms of delay and overhead.

  18. AUTOMATED INADVERTENT INTRUDER APPLICATION

    International Nuclear Information System (INIS)

    Koffman, L; Patricia Lee, P; Jim Cook, J; Elmer Wilhite, E

    2007-01-01

    The Environmental Analysis and Performance Modeling group of Savannah River National Laboratory (SRNL) conducts performance assessments of the Savannah River Site (SRS) low-level waste facilities to meet the requirements of DOE Order 435.1. These performance assessments, which result in limits on the amounts of radiological substances that can be placed in the waste disposal facilities, consider numerous potential exposure pathways that could occur in the future. One set of exposure scenarios, known as inadvertent intruder analysis, considers the impact on hypothetical individuals who are assumed to inadvertently intrude onto the waste disposal site. Inadvertent intruder analysis considers three distinct scenarios for exposure referred to as the agriculture scenario, the resident scenario, and the post-drilling scenario. Each of these scenarios has specific exposure pathways that contribute to the overall dose for the scenario. For the inadvertent intruder analysis, the calculation of dose for the exposure pathways is a relatively straightforward algebraic calculation that utilizes dose conversion factors. Prior to 2004, these calculations were performed using an Excel spreadsheet. However, design checks of the spreadsheet calculations revealed that errors could be introduced inadvertently when copying spreadsheet formulas cell by cell and finding these errors was tedious and time consuming. This weakness led to the specification of functional requirements to create a software application that would automate the calculations for inadvertent intruder analysis using a controlled source of input parameters. This software application, named the Automated Inadvertent Intruder Application, has undergone rigorous testing of the internal calculations and meets software QA requirements. The Automated Inadvertent Intruder Application was intended to replace the previous spreadsheet analyses with an automated application that was verified to produce the same calculations and

  19. Providers' knowledge, attitude and dispensing practices of e-pills in government dispensaries of South district in delhi, India.

    Science.gov (United States)

    Kishore, Vertika; Misro, Man M; Nandan, Deoki

    2010-01-01

    South Delhi is one of the well developed districts in the capital with best public health care facilities. Knowledge, attitude and dispensing practices of emergency contraceptive pills (E-pills) were assessed among health care providers of government dispensaries in South Delhi. A descriptive epidemiological study. Both medical and paramedical (n = 428) providers in 63 government health care facilities were interviewed between August to December 2007 using a semi-structured interview schedule. Among the different categories of the providers, medical officers were observed to be most knowledgeable about E-pills and the pharmacists were the least. The correct prescribed dose of E-pill was known only to 32% of the providers while 49% knew about its right time of intake. Misconceptions and apprehensions for promoting its use were very much prevalent even among medical officers as majority felt that open access to E-pills would increase promiscuity. The dispensing practice of providers was found positively (P pills.

  20. Hand sanitizer-dispensing door handles increase hand hygiene compliance: a pilot study.

    Science.gov (United States)

    Babiarz, Lukasz S; Savoie, Brent; McGuire, Mark; McConnell, Lauren; Nagy, Paul

    2014-04-01

    Improving rates of hand hygiene compliance (HHC) has been shown to reduce nosocomial disease. We compared the HHC for a traditional wall-mounted unit and a novel sanitizer-dispensing door handle device in a hospital inpatient ultrasound area. HHC increased 24.5%-77.1% (P sanitizer-dispensing door handle, whereas it remained unchanged for the other rooms. Technical improvements like a sanitizer-dispensing door handle can improve hospital HHC. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  1. A network collaboration implementing technology to improve medication dispensing and administration in critical access hospitals.

    Science.gov (United States)

    Wakefield, Douglas S; Ward, Marcia M; Loes, Jean L; O'Brien, John

    2010-01-01

    We report how seven independent critical access hospitals collaborated with a rural referral hospital to standardize workflow policies and procedures while jointly implementing the same health information technologies (HITs) to enhance medication care processes. The study hospitals implemented the same electronic health record, computerized provider order entry, pharmacy information systems, automated dispensing cabinets (ADC), and barcode medication administration systems. We conducted interviews and examined project documents to explore factors underlying the successful implementation of ADC and barcode medication administration across the network hospitals. These included a shared culture of collaboration; strategic sequencing of HIT component implementation; interface among HIT components; strategic placement of ADCs; disciplined use and sharing of workflow analyses linked with HIT applications; planning for workflow efficiencies; acquisition of adequate supply of HIT-related devices; and establishing metrics to monitor HIT use and outcomes.

  2. Methods for dispensing mercury into devices

    Science.gov (United States)

    Grossman, Mark W.; George, William A.

    1987-04-28

    A process for dispensing mercury into devices which requires mercury. Mercury is first electrolytically separated from either HgO or Hg.sub.2 Cl.sub.2 and plated onto a cathode wire. The cathode wire is then placed into a device requiring mercury.

  3. Calculation of normal tissue complication probability and dose-volume histogram reduction schemes for tissues with a critical element architecture

    International Nuclear Information System (INIS)

    Niemierko, Andrzej; Goitein, Michael

    1991-01-01

    The authors investigate a model of normal tissue complication probability for tissues that may be represented by a critical element architecture. They derive formulas for complication probability that apply to both a partial volume irradiation and to an arbitrary inhomogeneous dose distribution. The dose-volume isoeffect relationship which is a consequence of a critical element architecture is discussed and compared to the empirical power law relationship. A dose-volume histogram reduction scheme for a 'pure' critical element model is derived. In addition, a point-based algorithm which does not require precomputation of a dose-volume histogram is derived. The existing published dose-volume histogram reduction algorithms are analyzed. The authors show that the existing algorithms, developed empirically without an explicit biophysical model, have a close relationship to the critical element model at low levels of complication probability. However, it is also showed that they have aspects which are not compatible with a critical element model and the authors propose a modification to one of them to circumvent its restriction to low complication probabilities. (author). 26 refs.; 7 figs

  4. Feasibility evaluation of 3 automated cellular drug screening assays on a robotic workstation.

    Science.gov (United States)

    Soikkeli, Anne; Sempio, Cristina; Kaukonen, Ann Marie; Urtti, Arto; Hirvonen, Jouni; Yliperttula, Marjo

    2010-01-01

    This study presents the implementation and optimization of 3 cell-based assays on a TECAN Genesis workstation-the Caspase-Glo 3/7 and sulforhodamine B (SRB) screening assays and the mechanistic Caco-2 permeability protocol-and evaluates their feasibility for automation. During implementation, the dispensing speed to add drug solutions and fixative trichloroacetic acid and the aspiration speed to remove the supernatant immediately after fixation were optimized. Decontamination steps for cleaning the tips and pipetting tubing were also added. The automated Caspase-Glo 3/7 screen was successfully optimized with Caco-2 cells (Z' 0.7, signal-to-base ratio [S/B] 1.7) but not with DU-145 cells. In contrast, the automated SRB screen was successfully optimized with the DU-145 cells (Z' 0.8, S/B 2.4) but not with the Caco-2 cells (Z' -0.8, S/B 1.4). The automated bidirectional Caco-2 permeability experiments separated successfully low- and high-permeability compounds (Z' 0.8, S/B 84.2) and passive drug permeation from efflux-mediated transport (Z' 0.5, S/B 8.6). Of the assays, the homogeneous Caspase-Glo 3/7 assay benefits the most from automation, but also the heterogeneous SRB assay and Caco-2 permeability experiments gain advantages from automation.

  5. Community pharmacists’ attitudes and knowledge on dispensing drugs.

    Directory of Open Access Journals (Sweden)

    Baldon JP

    2006-03-01

    Full Text Available The present study aimed to assess knowledge and attitudes of the pharmacists on dispensing drugs to pregnant women. Methods: Cross-sectional study in 150 community pharmacies randomly selected in Curitiba (Brazil. A closed end questionnaire with 25 questions were used, including dispensing scenarios containing risk types A, B, D or X and questions on pharmacist interaction with pregnant women, physicians, and information sources availability. Results: Pharmacists performed appropriately in 53% of the encounters. Lower success were associated to prednison and captopril (24.8% in both, end cases producing more doubts were captopril (31.7% and simvastatin (30.7%. Most of the pharmacists state have advised drugs to pregnant women or contact to the physician to discuss about a prescription related with this issue. A Majority (64.4% did not feel able to understand FDA risk classification and did not have trustable information sources in pharmacy. Conclusions: Pharmacists dispensing drugs in Curitiba are not able to interpret information on the use of drugs in pregnant women, and they don have reliable information sources on the use of dugs in pregnancy. However, they advice and counsel drugs to pregnant women and discuss with physicians therapeutic strategies.

  6. High-Precision Dispensing of Nanoliter Biofluids on Glass Pedestal Arrays for Ultrasensitive Biomolecule Detection.

    Science.gov (United States)

    Chen, Xiaoxiao; Liu, Yang; Xu, QianFeng; Zhu, Jing; Poget, Sébastien F; Lyons, Alan M

    2016-05-04

    Precise dispensing of nanoliter droplets is necessary for the development of sensitive and accurate assays, especially when the availability of the source solution is limited. Conventional approaches are limited by imprecise positioning, large shear forces, surface tension effects, and high costs. To address the need for precise and economical dispensing of nanoliter volumes, we developed a new approach where the dispensed volume is dependent on the size and shape of defined surface features, thus freeing the dispensing process from pumps and fine-gauge needles requiring accurate positioning. The surface we fabricated, called a nanoliter droplet virtual well microplate (nVWP), achieves high-precision dispensing (better than ±0.5 nL or ±1.6% at 32 nL) of 20-40 nL droplets using a small source drop (3-10 μL) on isolated hydrophilic glass pedestals (500 μm on a side) bonded to arrays of polydimethylsiloxane conical posts. The sharp 90° edge of the glass pedestal pins the solid-liquid-vapor triple contact line (TCL), averting the wetting of the glass sidewalls while the fluid is prevented from receding from the edge. This edge creates a sufficiently large energy barrier such that microliter water droplets can be poised on the glass pedestals, exhibiting contact angles greater >150°. This approach relieves the stringent mechanical alignment tolerances required for conventional dispensing techniques, shifting the control of dispensed volume to the area circumscribed by the glass edge. The effects of glass surface chemistry and dispense velocity on droplet volume were studied using optical microscopy and high-speed video. Functionalization of the glass pedestal surface enabled the selective adsorption of specific peptides and proteins from synthetic and natural biomolecule mixtures, such as venom. We further demonstrate how the nVWP dispensing platform can be used for a variety of assays, including sensitive detection of proteins and peptides by fluorescence

  7. Determinants of Dispensing Location in the TRICARE Senior Pharmacy Program

    Science.gov (United States)

    2005-01-01

    proximity to an MTF on TSRx use and on uti - lization of the different dispensing locations; and the impact of MTF formulary restrictions on use of the...Conclusions and Policy Implications Our analysis of the TSRx program, which focused on describing uti - lization patterns by dispensing location and on...manufacturers do. In the public sector, some Medicaid programs have recently hired physicians and pharmacists to visit doctors’ offices and encourage them to

  8. Dispensing Equipment Testing with Mid-Level Ethanol/Gasoline Test Fluid: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, K.; Chapin, J. T.

    2010-11-01

    The National Renewable Energy Laboratory's (NREL) Nonpetroleum-Based Fuel Task addresses the hurdles to commercialization of biomass-derived fuels and fuel blends. One such hurdle is the unknown compatibility of new fuels with current infrastructure, such as the equipment used at service stations to dispense fuel into automobiles. The U.S. Department of Energy's (DOE) Vehicle Technology Program and the Biomass Program have engaged in a joint project to evaluate the potential for blending ethanol into gasoline at levels higher than nominal 10 volume percent. This project was established to help DOE and NREL better understand any potentially adverse impacts caused by a lack of knowledge about the compatibility of the dispensing equipment with ethanol blends higher than what the equipment was designed to dispense. This report provides data about the impact of introducing a gasoline with a higher volumetric ethanol content into service station dispensing equipment from a safety and a performance perspective.

  9. [Complex pathogenetic treatment schemes of vascular dyscirculatory disorders in the remote period after exposure to low dose radiation].

    Science.gov (United States)

    Holodova, N B; Zhavoronkova, L A; Ryzhov, B N

    2013-01-01

    Complex studies including modern methods of investigation of structures and functions of nervous system: electroencephalograsphy (EEG), coherent analysis, neuropsychological study and methods of neuroimaging were performed in 517 participants in liquidation of consequences of the accident (LCA) at the Chernobyl NPP in 1986-1987. Dyscirculatory metabolic encephalopathy was revealed to be the main pathology with the etiological mechanism based on dyscirculatorhypoxic and metabolic disorders. Complexity of the revealed symptoms testified to an early organism aging in remote periods after exposure to low dose radiation. Pathogenetic schemes were developed for treatment of dyscirculatory encephalopathy in liquidators, which include drugs improving blood supply, antiaggregants, antioxidants and metabolites of the brains in various combinations. Taking into consideration that early appearance of vascular dyscirculatory disorders observed in liquidators is the sign of early aging of the organism, geroprotectors were added to treatment schemes.

  10. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor.

    Science.gov (United States)

    Polo-López, M I; Fernández-Ibáñez, P; Ubomba-Jaswa, E; Navntoft, C; García-Fernández, I; Dunlop, P S M; Schmid, M; Byrne, J A; McGuigan, K G

    2011-11-30

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Fluorescence In Situ Hybridization (FISH Signal Analysis Using Automated Generated Projection Images

    Directory of Open Access Journals (Sweden)

    Xingwei Wang

    2012-01-01

    Full Text Available Fluorescence in situ hybridization (FISH tests provide promising molecular imaging biomarkers to more accurately and reliably detect and diagnose cancers and genetic disorders. Since current manual FISH signal analysis is low-efficient and inconsistent, which limits its clinical utility, developing automated FISH image scanning systems and computer-aided detection (CAD schemes has been attracting research interests. To acquire high-resolution FISH images in a multi-spectral scanning mode, a huge amount of image data with the stack of the multiple three-dimensional (3-D image slices is generated from a single specimen. Automated preprocessing these scanned images to eliminate the non-useful and redundant data is important to make the automated FISH tests acceptable in clinical applications. In this study, a dual-detector fluorescence image scanning system was applied to scan four specimen slides with FISH-probed chromosome X. A CAD scheme was developed to detect analyzable interphase cells and map the multiple imaging slices recorded FISH-probed signals into the 2-D projection images. CAD scheme was then applied to each projection image to detect analyzable interphase cells using an adaptive multiple-threshold algorithm, identify FISH-probed signals using a top-hat transform, and compute the ratios between the normal and abnormal cells. To assess CAD performance, the FISH-probed signals were also independently visually detected by an observer. The Kappa coefficients for agreement between CAD and observer ranged from 0.69 to 1.0 in detecting/counting FISH signal spots in four testing samples. The study demonstrated the feasibility of automated FISH signal analysis that applying a CAD scheme to the automated generated 2-D projection images.

  12. Pharmacy Professionals' Dispensing Practice, Knowledge, and Attitude towards Emergency Contraceptives in Gondar Town, Northwestern Ethiopia: A Cross-Sectional Study.

    Science.gov (United States)

    Belachew, Sewunet Admasu; Yimenu, Dawit Kumilachew; Gebresillassie, Begashaw Melaku

    2017-01-01

    Pharmacy professionals, as the most available members of medical team, have an important role in educating patients about the effective and appropriate use of contraceptives. The purpose of this study was to assess pharmacy professionals' dispensing practice, knowledge, and attitude towards emergency contraceptives use in Gondar town, northwestern Ethiopia. An institution based cross-sectional study was employed from May 14 to June 14, 2016, on 60 pharmacy professionals, who have been working in 8 randomly selected pharmacies and 6 drug stores. The collected data was entered to and analyzed using Statistical Packages for Social Sciences (SPSS) version 20. More than half 33 (55.0%) of the participants were druggist with 5-9 years of experience. About 56 (93.3%) of the participants knew about the dosing schedule (when and how much to take) and side effects of emergency contraceptives. More than two-thirds of the participants (39, 65%) agreed that the existence of emergency contraceptives is a positive thing and considered their use is ethical (42, 63.3%). The majority of participants (51, 85%) also reported that they counsel all women when dispensing emergency contraceptive pills (ECPs). This study revealed that knowledge, attitude, and dispensing practice of emergency contraceptives are very good even though there were variations with respect to different factors. Findings suggested that additional training and proper counseling technique on emergency contraceptives will improve the service delivery.

  13. Through-Silicon-Via Underfill Dispensing for 3D Die/Interposer Stacking

    Science.gov (United States)

    Le, Fuliang

    The next generation packaging keeps up with the increased demands of functionality by using the third dimension. 3D chip stacking with TSVs has been identified as one of the major technologies to achieve higher silicon density and shorter interconnection. In order to protect solder interconnections from hostile environments and redistribute thermal stress caused by CTE mismatch, underfill should be applied for the under-chip spaces. In this study, TSV underfill dispensing is introduced to address the underfill challenge for 3D chip stacks. The material properties are first measured and the general trend indicates viscosity and contact angle dropping significantly with an increase in temperature, and surface tension falling slightly as the temperature increases. Underfill should assure a complete encapsulation, avoiding excessive filling time that can result in substantial manufacturing delays. Typically, the inflows for TSV underfill can be free droplets or a constant flow rate. For a constant inflow, the underfill flow is driven by pressure difference and the filling time is governed by flow radius, gap clearance and the constant flow rate. For an inflow of free droplets, the underfill flow is driven by capillary action and the filling time is related to viscosity, flow radius, gap clearance, surface tension, contact angle and TSV size. In general, TSV underfill dispensing with a constant inflow has much shorter filling time than dispensing with an inflow of free droplets. TSV underfill dispensing on a 3D chip stack may induce the risk of an edge flood failure. In order to avoid an edge flood, fluid pressure around the sidewalls of a 3D chip stack cannot exceed limit equilibrium pressure. For TSV dispensing with free droplets, there is no risk of forming an edge flood. However, for a constant inflow, TSV dispensing should be carefully controlled to avoid excessive pressure. Besides, it is suggested that the TSVs in stacked chips be aligned in the vertical

  14. SensorScheme: Supply Chain Management Automation using Wireless Sensor Networks

    NARCIS (Netherlands)

    Evers, L.; Havinga, Paul J.M.; Kuper, Jan; Lijding, M.E.M.; Meratnia, Nirvana

    2007-01-01

    The supply chain management business can benefit greatly from automation, as recent developments with RFID technology shows. The use of Wireless Sensor Network technology promises to bring the next leap in efficiency and quality of service. However, current WSN system software does not yet provide

  15. Remote access and automation of SPring-8 MX beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Go, E-mail: ueno@spring8.or.jp; Hikima, Takaaki; Yamashita, Keitaro; Hirata, Kunio; Yamamoto, Masaki [RIKEN SPring-8 Center, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5148 JAPAN (Japan); Hasegawa, Kazuya; Murakami, Hironori; Furukawa, Yukito; Mizuno, Nobuhiro; Kumasaka, Takashi [SPring-8/JASRI, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5198 JAPAN (Japan)

    2016-07-27

    At SPring-8 MX beamlines, a remote access system has been developed and started user operation in 2010. The system has been developed based on an automated data collection and data management architecture utilized for the confirmed scheme of SPring-8 mail-in data collection. Currently, further improvement to the remote access and automation which covers data processing and analysis are being developed.

  16. Numerical Simulation Analysis of High-precision Dispensing Needles for Solid-liquid Two-phase Grinding

    Science.gov (United States)

    Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming

    2018-03-01

    In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.

  17. Dispensing with conscience: a legal and ethical assessment.

    Science.gov (United States)

    Wernow, Jerome R; Grant, Donald G

    2008-11-01

    For over 30 years, pharmacists have exercised the right to dispense medications in accordance with moral convictions based upon a Judeo-Christian ethic. What many of these practitioners see as an apparent shift away from this time-honored ethic has resulted in a challenge to this right. To review and analyze pharmacy practice standards, legal proceedings, and ethical principles behind conflicts of conscientious objection in dispensing drugs used for emergency contraception. We first searched the terms conscience and clause and Plan B and contraception and abortion using Google, Yahoo, and Microsoft Networks (2006-September 26, 2008). Second, we used Medscape to search professional pharmacy and other medical journals, restricting our terms to conscience, Plan B, contraceptives, and abortifacients. Finally, we employed Loislaw, an online legal archiving service, and did a global search on the phrase conscience clause to determine the status of the legal discussion. To date, conflicts in conscientious objection have arisen when a pharmacist believes that dispensing an oral contraceptive violates his or her moral understanding for the promotion of human life. Up to this time, cases in pharmacy have involved only practitioners from orthodox Christian faith communities, primarily devout Roman Catholics. A pharmacist's right to refuse the dispensing of abortifacients for birth control according to moral conscience over against a woman's right to reproductive birth control has created a conflict that has yet to be reconciled by licensing agents, professional standards, or courts of law. Our analysis of prominent conflicts suggests that the underlying worldviews between factions make compromise improbable. Risks and liabilities are dependent upon compliance with evolving state laws, specific disclosure of a pharmacist's moral objections, and professionalism in the handling of volatile situations. Objecting pharmacists and their employers should have clear policies and

  18. Alcohol Dispenser Training in Amherst Massachusetts

    Science.gov (United States)

    Riccelli, Carlene

    1986-01-01

    Reviews efforts of the Alcohol Dispenser Training program in Amherst, Massachusetts over a five-year period. Evaluations indicate that participants agree that training is worthwhile, that they are more aware of the effects of alcohol on their patrons, and that they have better knowledge of appropriate strategies for preventing intoxication of…

  19. MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT. NATIONAL SANITATION FOUNDATION STANDARD NO. 18.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    THIS STANDARD COVERS THE SANITATION REQUIREMENTS FOR EQUIPMENT AND DEVICES WHICH DISPENSE FOOD OR BEVERAGE EITHER IN BULK OR PORTIONS. VENDING MACHINES OR BULK MILK DISPENSING EQUIPMENT ARE NOT COVERED IN THIS STANDARD. ITEMS COVERED INCLUDE THE BASIC PRINCIPLES OF DESIGN AND CONSTRUCTION, FOOD PROTECTION AND FREEDOM FROM HARBORAGES. MINIMUM…

  20. Designing an automated blood fractionation system.

    Science.gov (United States)

    McQuillan, Adrian C; Sales, Sean D

    2008-04-01

    UK Biobank will be collecting blood samples from a cohort of 500 000 volunteers and it is expected that the rate of collection will peak at approximately 3000 blood collection tubes per day. These samples need to be prepared for long-term storage. It is not considered practical to manually process this quantity of samples so an automated blood fractionation system is required. Principles of industrial automation were applied to the blood fractionation process leading to the requirement of developing a vision system to identify the blood fractions within the blood collection tube so that the fractions can be accurately aspirated and dispensed into micro-tubes. A prototype was manufactured and tested on a range of human blood samples collected in different tube types. A specially designed vision system was capable of accurately measuring the position of the plasma meniscus, plasma/buffy coat interface and the red cells/buffy coat interface within a vacutainer. A rack of 24 vacutainers could be processed in blood fractionation system offers a solution to the problem of processing human blood samples collected in vacutainers in a consistent manner and provides a means of ensuring data and sample integrity.

  1. Hard beta and gamma emissions of 124I. Impact on occupational dose in PET/CT.

    Science.gov (United States)

    Kemerink, G J; Franssen, R; Visser, M G W; Urbach, C J A; Halders, S G E A; Frantzen, M J; Brans, B; Teule, G J J; Mottaghy, F M

    2011-01-01

    The hard beta and gamma radiation of 124I can cause high doses to PET/CT workers. In this study we tried to quantify this occupational exposure and to optimize radioprotection. Thin MCP-Ns thermoluminescent dosimeters suitable for measuring beta and gamma radiation were used for extremity dosimetry, active personal dosimeters for whole-body dosimetry. Extremity doses were determined during dispensing of 124I and oral administration of the activity to the patient, the body dose during all phases of the PET/CT procedure. In addition, dose rates of vials and syringes as used in clinical practice were measured. The procedure for dispensing 124I was optimized using newly developed shielding. Skin dose rates up to 100 mSv/min were measured when in contact with the manufacturer's vial containing 370 MBq of 124I. For an unshielded 5 ml syringe the positron skin dose was about seven times the gamma dose. Before optimization of the preparation of 124I, using an already reasonably safe technique, the highest mean skin dose caused by handling 370 MBq was 1.9 mSv (max. 4.4 mSv). After optimization the skin dose was below 0.2 mSv. The highly energetic positrons emitted by 124I can cause high skin doses if radioprotection is poor. Under optimized conditions occupational doses are acceptable. Education of workers is of paramount importance.

  2. Automated lung nodule classification following automated nodule detection on CT: A serial approach

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Altman, Michael B.; Wilkie, Joel; Sone, Shusuke; Li, Feng; Doi, Kunio; Roy, Arunabha S.

    2003-01-01

    We have evaluated the performance of an automated classifier applied to the task of differentiating malignant and benign lung nodules in low-dose helical computed tomography (CT) scans acquired as part of a lung cancer screening program. The nodules classified in this manner were initially identified by our automated lung nodule detection method, so that the output of automated lung nodule detection was used as input to automated lung nodule classification. This study begins to narrow the distinction between the 'detection task' and the 'classification task'. Automated lung nodule detection is based on two- and three-dimensional analyses of the CT image data. Gray-level-thresholding techniques are used to identify initial lung nodule candidates, for which morphological and gray-level features are computed. A rule-based approach is applied to reduce the number of nodule candidates that correspond to non-nodules, and the features of remaining candidates are merged through linear discriminant analysis to obtain final detection results. Automated lung nodule classification merges the features of the lung nodule candidates identified by the detection algorithm that correspond to actual nodules through another linear discriminant classifier to distinguish between malignant and benign nodules. The automated classification method was applied to the computerized detection results obtained from a database of 393 low-dose thoracic CT scans containing 470 confirmed lung nodules (69 malignant and 401 benign nodules). Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate between nodule candidates that correspond to malignant nodules and nodule candidates that correspond to benign lesions. The area under the ROC curve for this classification task attained a value of 0.79 during a leave-one-out evaluation

  3. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  4. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  5. A Multiserver Biometric Authentication Scheme for TMIS using Elliptic Curve Cryptography.

    Science.gov (United States)

    Chaudhry, Shehzad Ashraf; Khan, Muhammad Tawab; Khan, Muhammad Khurram; Shon, Taeshik

    2016-11-01

    Recently several authentication schemes are proposed for telecare medicine information system (TMIS). Many of such schemes are proved to have weaknesses against known attacks. Furthermore, numerous such schemes cannot be used in real time scenarios. Because they assume a single server for authentication across the globe. Very recently, Amin et al. (J. Med. Syst. 39(11):180, 2015) designed an authentication scheme for secure communication between a patient and a medical practitioner using a trusted central medical server. They claimed their scheme to extend all security requirements and emphasized the efficiency of their scheme. However, the analysis in this article proves that the scheme designed by Amin et al. is vulnerable to stolen smart card and stolen verifier attacks. Furthermore, their scheme is having scalability issues along with inefficient password change and password recovery phases. Then we propose an improved scheme. The proposed scheme is more practical, secure and lightweight than Amin et al.'s scheme. The security of proposed scheme is proved using the popular automated tool ProVerif.

  6. Evaluation of community pharmacies regarding dispensing practices of antibiotics in two districts of central Nepal.

    Directory of Open Access Journals (Sweden)

    Mukhtar Ansari

    Full Text Available To evaluate the status of community pharmacies, their staff, and practices toward dispensing antibiotics.Cross-sectional, prospective.Community pharmacies in two districts of central Nepal, from March 2016 to May 2016.A systematic random sampling approach was adopted to sample 161 community pharmacies. Data on the registration status of pharmacies, qualification or training of dispensing staff, and the practice of dispensing antibiotics were collected using a pre-tested questionnaire. Face to face interviews were carried out by a previously trained interviewer. Data were analyzed for descriptive and inferential statistics using IBM SPSS Statistics 21.Among 161 community pharmacies, 25% were not registered and most of them were located in rural areas. It was typical (66.5% to dispense antibiotics without prescription and most (91.4% of the staffs involved in dispensing were non-pharmacists. Furthermore, the study revealed common practices of replacing one brand of antibiotic with other brands (66%, dispensing incomplete courses of antibiotics (73%, and not giving any advice regarding antibiotic use (39% or completion of a full course of therapy (80%. There were significant (p < 0.001 relationships between the location of pharmacies (rural vs urban and the qualifications of the pharmacy staff.Dispensing antibiotics without prescription and by non-pharmacists are common in this region. The study also found several issues regarding the irrational use of antibiotics. Thus, there is an urgent need to address these issues and promote the informed use of antibiotics.

  7. Robotic automation of medication-use management.

    Science.gov (United States)

    Enright, S M

    1993-11-01

    In the October 1993 issue of Physician Assistant, we published "Robots for Health Care," the first of two articles on the medical applications of robotics. That article discussed ways in which robots could help patients with manipulative disabilities to perform activities of daily living and hold paid employment; transfer patients from bed to chair and back again; add precision to the most exacting surgical procedures; and someday carry out diagnostic and therapeutic techniques from within the human body. This month, we are pleased to offer an article by Sharon Enright, an authority on pharmacy operations, who considers how an automated medication-management system that makes use of bar-code technology is capable of streamlining drug dispensing, controlling safety, increasing cost-effectiveness, and ensuring accurate and complete record-keeping.

  8. Plant automation

    International Nuclear Information System (INIS)

    Christensen, L.J.; Sackett, J.I.; Dayal, Y.; Wagner, W.K.

    1989-01-01

    This paper describes work at EBR-II in the development and demonstration of new control equipment and methods and associated schemes for plant prognosis, diagnosis, and automation. The development work has attracted the interest of other national laboratories, universities, and commercial companies. New initiatives include use of new control strategies, expert systems, advanced diagnostics, and operator displays. The unique opportunity offered by EBR-II is as a test bed where a total integrated approach to automatic reactor control can be directly tested under real power plant conditions

  9. An automated thermoluminescence dosimetry (TLD) system

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Huyskens, C.J.

    1979-01-01

    In the Health Physics Division of the Eindhoven University of Technology work is going on in developing an automated TLD-system. Process automization, statistical computation, dose calculation as well as dose recording are carried out, using a microcomputer and floppy disk unit. The main features of this TLD-system are its low costs, flexibility, easy to operate, and the feasibility for use in routine dosimetry as well as in complex TLD research. Because of its modular set-up several components of the system are multifunctional in other operations. The system seems suited for medium sized Health Physics groups. (Auth.)

  10. Implementing a bar-code assisted medication administration system: effects on the dispensing process and user perceptions.

    Science.gov (United States)

    Samaranayake, N R; Cheung, S T D; Cheng, K; Lai, K; Chui, W C M; Cheung, B M Y

    2014-06-01

    We assessed the effects of a bar-code assisted medication administration system used without the support of computerised prescribing (stand-alone BCMA), on the dispensing process and its users. The stand-alone BCMA system was implemented in one ward of a teaching hospital. The number of dispensing steps, dispensing time and potential dispensing errors (PDEs) were directly observed one month before and eight months after the intervention. Attitudes of pharmacy and nursing staff were assessed using a questionnaire (Likert scale) and interviews. Among 1291 and 471 drug items observed before and after the introduction of the technology respectively, the number of dispensing steps increased from five to eight and time (standard deviation) to dispense one drug item by one staff personnel increased from 0.8 (0.09) to 1.5 (0.12) min. Among 2828 and 471 drug items observed before and after the intervention respectively, the number of PDEs increased significantly (Psystem offered less benefit to the dispensing process (9/16). Nursing staff perceived the system as useful in improving the accuracy of drug administration (7/10). Implementing a stand-alone BCMA system may slow down and complicate the dispensing process. Nursing staff believe the stand-alone BCMA system could improve the drug administration process but pharmacy staff believes the technology would be more helpful if supported by computerised prescribing. However, periodical assessments are needed to identify weaknesses in the process after implementation, and all users should be educated on the benefits of using this technology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Pharmacy Professionals’ Dispensing Practice, Knowledge, and Attitude towards Emergency Contraceptives in Gondar Town, Northwestern Ethiopia: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Sewunet Admasu Belachew

    2017-01-01

    Full Text Available Background. Pharmacy professionals, as the most available members of medical team, have an important role in educating patients about the effective and appropriate use of contraceptives. The purpose of this study was to assess pharmacy professionals’ dispensing practice, knowledge, and attitude towards emergency contraceptives use in Gondar town, northwestern Ethiopia. Methods. An institution based cross-sectional study was employed from May 14 to June 14, 2016, on 60 pharmacy professionals, who have been working in 8 randomly selected pharmacies and 6 drug stores. The collected data was entered to and analyzed using Statistical Packages for Social Sciences (SPSS version 20. Result. More than half 33 (55.0% of the participants were druggist with 5–9 years of experience. About 56 (93.3% of the participants knew about the dosing schedule (when and how much to take and side effects of emergency contraceptives. More than two-thirds of the participants (39, 65% agreed that the existence of emergency contraceptives is a positive thing and considered their use is ethical (42, 63.3%. The majority of participants (51, 85% also reported that they counsel all women when dispensing emergency contraceptive pills (ECPs. Conclusion. This study revealed that knowledge, attitude, and dispensing practice of emergency contraceptives are very good even though there were variations with respect to different factors. Findings suggested that additional training and proper counseling technique on emergency contraceptives will improve the service delivery.

  12. An Automated Motion Detection and Reward System for Animal Training.

    Science.gov (United States)

    Miller, Brad; Lim, Audrey N; Heidbreder, Arnold F; Black, Kevin J

    2015-12-04

    A variety of approaches has been used to minimize head movement during functional brain imaging studies in awake laboratory animals. Many laboratories expend substantial effort and time training animals to remain essentially motionless during such studies. We could not locate an "off-the-shelf" automated training system that suited our needs.  We developed a time- and labor-saving automated system to train animals to hold still for extended periods of time. The system uses a personal computer and modest external hardware to provide stimulus cues, monitor movement using commercial video surveillance components, and dispense rewards. A custom computer program automatically increases the motionless duration required for rewards based on performance during the training session but allows changes during sessions. This system was used to train cynomolgus monkeys (Macaca fascicularis) for awake neuroimaging studies using positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). The automated system saved the trainer substantial time, presented stimuli and rewards in a highly consistent manner, and automatically documented training sessions. We have limited data to prove the training system's success, drawn from the automated records during training sessions, but we believe others may find it useful. The system can be adapted to a range of behavioral training/recording activities for research or commercial applications, and the software is freely available for non-commercial use.

  13. [Quality evaluation of rhubarb dispensing granules based on multi-component simultaneous quantitative analysis and bioassay].

    Science.gov (United States)

    Tan, Peng; Zhang, Hai-Zhu; Zhang, Ding-Kun; Wu, Shan-Na; Niu, Ming; Wang, Jia-Bo; Xiao, Xiao-He

    2017-07-01

    This study attempts to evaluate the quality of Chinese formula granules by combined use of multi-component simultaneous quantitative analysis and bioassay. The rhubarb dispensing granules were used as the model drug for demonstrative study. The ultra-high performance liquid chromatography (UPLC) method was adopted for simultaneously quantitative determination of the 10 anthraquinone derivatives (such as aloe emodin-8-O-β-D-glucoside) in rhubarb dispensing granules; purgative biopotency of different batches of rhubarb dispensing granules was determined based on compound diphenoxylate tablets-induced mouse constipation model; blood activating biopotency of different batches of rhubarb dispensing granules was determined based on in vitro rat antiplatelet aggregation model; SPSS 22.0 statistical software was used for correlation analysis between 10 anthraquinone derivatives and purgative biopotency, blood activating biopotency. The results of multi-components simultaneous quantitative analysisshowed that there was a great difference in chemical characterizationand certain differences inpurgative biopotency and blood activating biopotency among 10 batches of rhubarb dispensing granules. The correlation analysis showed that the intensity of purgative biopotency was significantly correlated with the content of conjugated anthraquinone glycosides (Panalysis and bioassay can achieve objective quantification and more comprehensive reflection on overall quality difference among different batches of rhubarb dispensing granules. Copyright© by the Chinese Pharmaceutical Association.

  14. Nanoliter Centrifugal Liquid Dispenser Coupled with Superhydrophobic Microwell Array Chips for High-Throughput Cell Assays

    Directory of Open Access Journals (Sweden)

    Yuyi Wang

    2018-06-01

    Full Text Available Microfluidic systems have been regarded as a potential platform for high-throughput screening technology in drug discovery due to their low sample consumption, high integration, and easy operation. The handling of small-volume liquid is an essential operation in microfluidic systems, especially in investigating large-scale combination conditions. Here, we develop a nanoliter centrifugal liquid dispenser (NanoCLD coupled with superhydrophobic microwell array chips for high-throughput cell-based assays in the nanoliter scale. The NanoCLD consists of a plastic stock block with an array of drilled through holes, a reagent microwell array chip (reagent chip, and an alignment bottom assembled together in a fixture. A simple centrifugation at 800 rpm can dispense ~160 nL reagents into microwells in 5 min. The dispensed reagents are then delivered to cells by sandwiching the reagent chip upside down with another microwell array chip (cell chip on which cells are cultured. A gradient of doxorubicin is then dispensed to the cell chip using the NanoCLD for validating the feasibility of performing drug tests on our microchip platform. This novel nanoliter-volume liquid dispensing method is simple, easy to operate, and especially suitable for repeatedly dispensing many different reagents simultaneously to microwells.

  15. Distance traveled and frequency of interstate opioid dispensing in opioid shoppers and nonshoppers.

    Science.gov (United States)

    Cepeda, M Soledad; Fife, Daniel; Yuan, Yingli; Mastrogiovanni, Greg

    2013-10-01

    Little is known about how far opioid shoppers travel or how often they cross state lines to fill their opioid prescriptions. This retrospective cohort study evaluated these measures for opioid shoppers and nonshoppers using a large U.S. prescription database. Patients with ≥3 opioid dispensings were followed for 18 months. A subject was considered a shopper when he or she filled overlapping opioid prescriptions written by >1 prescriber at ≥3 pharmacies. A heavy shopper had ≥5 shopping episodes. Outcomes assessed were distance traveled among pharmacies and number of states visited to fill opioid prescriptions. A total of 10,910,451 subjects were included; .7% developed any shopping behavior and their prescriptions accounted for 8.6% of all opioid dispensings. Shoppers and heavy shoppers were younger than the nonshoppers. Shoppers traveled a median of 83.8 miles, heavy shoppers 199.5 miles, and nonshoppers 0 miles. Almost 20% of shoppers or heavy shoppers, but only 4% of nonshoppers, visited >1 state. Shoppers traveled greater distances and more often crossed state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. Sharing of data among prescription-monitoring programs will likely strengthen those programs and may decrease shopping behavior. This study shows that opioid shoppers travel greater distances and more often cross state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. The findings support the need for data sharing among prescription-monitoring programs to deter opioid shopping behavior. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  16. Automated analysis in generic groups

    Science.gov (United States)

    Fagerholm, Edvard

    This thesis studies automated methods for analyzing hardness assumptions in generic group models, following ideas of symbolic cryptography. We define a broad class of generic and symbolic group models for different settings---symmetric or asymmetric (leveled) k-linear groups --- and prove ''computational soundness'' theorems for the symbolic models. Based on this result, we formulate a master theorem that relates the hardness of an assumption to solving problems in polynomial algebra. We systematically analyze these problems identifying different classes of assumptions and obtain decidability and undecidability results. Then, we develop automated procedures for verifying the conditions of our master theorems, and thus the validity of hardness assumptions in generic group models. The concrete outcome is an automated tool, the Generic Group Analyzer, which takes as input the statement of an assumption, and outputs either a proof of its generic hardness or shows an algebraic attack against the assumption. Structure-preserving signatures are signature schemes defined over bilinear groups in which messages, public keys and signatures are group elements, and the verification algorithm consists of evaluating ''pairing-product equations''. Recent work on structure-preserving signatures studies optimality of these schemes in terms of the number of group elements needed in the verification key and the signature, and the number of pairing-product equations in the verification algorithm. While the size of keys and signatures is crucial for many applications, another aspect of performance is the time it takes to verify a signature. The most expensive operation during verification is the computation of pairings. However, the concrete number of pairings is not captured by the number of pairing-product equations considered in earlier work. We consider the question of what is the minimal number of pairing computations needed to verify structure-preserving signatures. We build an

  17. Global real-time dose measurements using the Automated Radiation Measurements for Aerospace Safety (ARMAS) system

    Science.gov (United States)

    Tobiska, W. Kent; Bouwer, D.; Smart, D.; Shea, M.; Bailey, J.; Didkovsky, L.; Judge, K.; Garrett, H.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R.; Bell, D.; Mertens, C.; Xu, X.; Wiltberger, M.; Wiley, S.; Teets, E.; Jones, B.; Hong, S.; Yoon, K.

    2016-11-01

    The Automated Radiation Measurements for Aerospace Safety (ARMAS) program has successfully deployed a fleet of six instruments measuring the ambient radiation environment at commercial aircraft altitudes. ARMAS transmits real-time data to the ground and provides quality, tissue-relevant ambient dose equivalent rates with 5 min latency for dose rates on 213 flights up to 17.3 km (56,700 ft). We show five cases from different aircraft; the source particles are dominated by galactic cosmic rays but include particle fluxes for minor radiation periods and geomagnetically disturbed conditions. The measurements from 2013 to 2016 do not cover a period of time to quantify galactic cosmic rays' dependence on solar cycle variation and their effect on aviation radiation. However, we report on small radiation "clouds" in specific magnetic latitude regions and note that active geomagnetic, variable space weather conditions may sufficiently modify the magnetospheric magnetic field that can enhance the radiation environment, particularly at high altitudes and middle to high latitudes. When there is no significant space weather, high-latitude flights produce a dose rate analogous to a chest X-ray every 12.5 h, every 25 h for midlatitudes, and every 100 h for equatorial latitudes at typical commercial flight altitudes of 37,000 ft ( 11 km). The dose rate doubles every 2 km altitude increase, suggesting a radiation event management strategy for pilots or air traffic control; i.e., where event-driven radiation regions can be identified, they can be treated like volcanic ash clouds to achieve radiation safety goals with slightly lower flight altitudes or more equatorial flight paths.

  18. A systematic approach for the location of hand sanitizer dispensers in hospitals.

    Science.gov (United States)

    Cure, Laila; Van Enk, Richard; Tiong, Ewing

    2014-09-01

    Compliance with hand hygiene practices is directly affected by the accessibility and availability of cleaning agents. Nevertheless, the decision of where to locate these dispensers is often not explicitly or fully addressed in the literature. In this paper, we study the problem of selecting the locations to install alcohol-based hand sanitizer dispensers throughout a hospital unit as an indirect approach to maximize compliance with hand hygiene practices. We investigate the relevant criteria in selecting dispenser locations that promote hand hygiene compliance, propose metrics for the evaluation of various location configurations, and formulate a dispenser location optimization model that systematically incorporates such criteria. A complete methodology to collect data and obtain the model parameters is described. We illustrate the proposed approach using data from a general care unit at a collaborating hospital. A cost analysis was performed to study the trade-offs between usability and cost. The proposed methodology can help in evaluating the current location configuration, determining the need for change, and establishing the best possible configuration. It can be adapted to incorporate alternative metrics, tailored to different institutions and updated as needed with new internal policies or safety regulation.

  19. How can pharmacist remuneration systems in Europe contribute to generic medicine dispensing?

    Directory of Open Access Journals (Sweden)

    Dylst P

    2012-03-01

    Full Text Available Generic medicines can generate larger savings to health care budgets when their use is supported by incentives on both the supply-side and the demand-side. Pharmacists’ remuneration is one factor influencing the dispensing of generic medicines.Objective: The aim of this article is to provide an overview of different pharmacist remuneration systems for generic medicines in Europe, with a view to exploring how pharmacist remuneration systems can contribute to generic medicine dispensing.Methods: Data were obtained from a literature review, a Master thesis in Pharmaceutical Care at the Catholic University of Leuven and a mailing sent to all members of the Pharmaceutical Group of the European Union with a request for information about the local remuneration systems of community pharmacists and the possible existence of reports on discounting practices.Results: Pharmacists remuneration in most European countries consists of the combination of a fixed fee per item and a certain percentage of the acquisition cost or the delivery price of the medicines. This percentage component can be fixed, regressive or capped for very high-cost medicines and acts as a disincentive for dispensing generic medicines. Discounting for generic medicines is common practice in several European countries but information on this practice tends to be confidential. Nevertheless, data for Belgium, France, the Netherlands and United Kingdom indicated that discounting percentages varied from 10% to 70% of the wholesale selling price.Conclusion: Pharmacists can play an important role in the development of a generic medicines market. Pharmacists should not be financially penalized for dispensing generic medicines. Therefore, their remuneration should move towards a fee-for-performance remuneration instead of a price-dependent reimbursement which is currently used in many European countries. Such a fee-for-performance remuneration system provides a stimulus for generic medicines

  20. Foreign private capital inflows in Nigeria's democratic dispensation ...

    African Journals Online (AJOL)

    FPCI) in Nigeria in the current democratic dispensation with a view to finding out whether the inflows have recorded significant increase since the institution of Democracy in the country. Relevant theories and empirical data were reviewed.

  1. Efficacy of a Feed Dispenser for Horses in Decreasing Cribbing Behaviour

    Directory of Open Access Journals (Sweden)

    Silvia Mazzola

    2016-01-01

    Full Text Available Cribbing is an oral stereotypy, tends to develop in captive animals as a means to cope with stress, and may be indicative of reduced welfare. Highly energetic diets ingested in a short time are one of the most relevant risk factors for the development of cribbing. The aim of this study was to verify whether feeding cribbing horses through a dispenser that delivers small quantities of concentrate when activated by the animal decreases cribbing behaviour, modifies feeding behaviour, or induces frustration. Ten horses (mean age 14 y, balanced for sex, breed, and size (mean height 162 cm, were divided into two groups of 5 horses each: Cribbing and Control. Animals were trained to use the dispenser and videorecorded continuously for 15 consecutive days from 1 h prior to feeding to 2 h after feeding in order to measure their behaviours. The feed dispenser, Quaryka®, induced an increase in time necessary to finish the ration in both groups of horses (P<0.05. With Quaryka, cribbers showed a significant reduction of time spent cribbing (P<0.05. After removal of the feed dispenser (Post-Quaryka, cribbing behaviour significantly increased. The use of Quaryka may be particularly beneficial in horses fed high-energy diets and ingesting the food too quickly.

  2. [Design and piloting of a structured service medication dispensing process].

    Science.gov (United States)

    Abaurre, Raquel; García-Delgado, Pilar; Maurandi, M Dolores; Arrebola, Cristóbal; Gastelurrutia, Miguel Ángel; Martínez-Martínez, Fernando

    2015-01-01

    The aim of this article is to design and pilot a protocol for the dispensing of medications service. Using the requirements proposed in the Ministry of Health Pharmaceutical Care Consensus, a literature search was made applying qualitative consensus techniques. An observational, cross-sectional study was conducted from March to June 2009. A total of 53 community pharmacies from 24 Spanish counties. Patients who requested one or more particular medications with or without medical prescription for their own use or for someone in their care. The personalised medication information (IPM), the problems associated with the medications (PRM), and the negative results associated with the medication (RNM), detected by the pharmacist each time medication was dispensed, as well as the perception of the pharmacist on the operability of the protocol were recorded. A total of 870 medications were dispensed, with 423 (48.6%) cases of lack of personalised medication information (IPM) being detected. PRM were detected in 10.11% of the dispensed medications, as well as 68 (7.81%) suspected RNM: safety (n = 35; 51.5%), effectiveness (n = 29; 42.6%) and necessity (n = 4; 5.8%). Almost two-thirds (65.21%) of the pharmacists said that the protocol is in operation. The designed protocol helped to detect deficiencies in the information to the patients about their medications, as well as the PRM and RNM, and is shown to be tool that is easy to use and apply. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  3. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500... a mechanical device intended for medical purposes to dispense or serially dilute very small...

  4. Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    May, Matthias S.; Uder, Michael; Lell, Michael M. [University Hospital Erlangen, Department of Radiology, Erlangen (Germany); University Erlangen, Imaging Science Institute, Erlangen (Germany); Kramer, Manuel R.; Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael; Saake, Marc [University Hospital Erlangen, Department of Radiology, Erlangen (Germany); Schmidt, Bernhard [Siemens Healthcare, Erlangen (Germany)

    2014-09-15

    Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDI{sub vol}. Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7-8 %. TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality. (orig.)

  5. Source terms and releases in routine and accidental situations: the scheme implemented at the Joint Research Centre in Ispra for the evaluation of the dose to the population

    International Nuclear Information System (INIS)

    D'Alberti, F.

    2004-01-01

    This paper presents the scheme and the tools implemented for the evaluation of the dose to the population due to the routine and emergency situations of the nuclear installations at the Joint Research Centre in Ispra. In particular, it will be introduced and discussed the use of models provided by commercial software and international technical recommendations. The approach for all the calculations required the usual conservative hypotheses, so that the maximum dose results have been derived. The dose evaluations have been performed retrospectively, for the years 1990-2002. The doses are evaluated net of the doses due to the naturally occurring radioactivity. (author)

  6. Automated hand hygiene auditing with and without an intervention.

    Science.gov (United States)

    Kwok, Yen Lee Angela; Juergens, Craig P; McLaws, Mary-Louise

    2016-12-01

    Daily feedback from continuous automated auditing with a peer reminder intervention was used to improve compliance. Compliance rates from covert and overt automated auditing phases with and without intervention were compared with human mandatory audits. An automated system was installed to covertly detect hand hygiene events with each depression of the alcohol-based handrub dispenser for 5 months. The overt phase included key clinicians trained to share daily rates with clinicians, set compliance goals, and nudge each other to comply for 6 months. During a further 6 months, the intervention continued without being refreshed. Hand Hygiene Australia (HHA) human audits were performed quarterly during the intervention in accordance with the World Health Organization guidelines. Percentage point (PP) differences between compliance rates were used to determine change. HHA rates for June 2014 were 85% and 87% on the medical and surgical wards, respectively. These rates were 55 PPs and 38 PPs higher than covert automation rates for June 2014 on the medical and surgical ward at 30% and 49%, respectively. During the intervention phase, average compliance did not change on the medical ward from their covert rate, whereas the surgical ward improved compared with the covert phase by 11 PPs to 60%. On average, compliance during the intervention without being refreshed did not change on the medical ward, whereas the average rate on the surgical ward declined by 9 PPs. Automation provided a unique opportunity to respond to daily rates, but compliance will return to preintervention levels once active intervention ceases or human auditors leave the ward, unless clinicians are committed to change. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  7. The expected and unexpected benefits of dispensing the exact number of pills.

    Science.gov (United States)

    Treibich, Carole; Lescher, Sabine; Sagaon-Teyssier, Luis; Ventelou, Bruno

    2017-01-01

    From November 2014 to November 2015, an experiment in French community pharmacies replaced traditional pre-packed boxes by per-unit dispensing of pills in the exact numbers prescribed, for 14 antibiotics. A cluster randomised control trial was carried out in 100 pharmacies. 75 pharmacies counted out the medication by units (experimental group), the other 25 providing the treatment in the existing pharmaceutical company boxes (control group). Data on patients under the two arms were compared to assess the environmental, economic and health effects of this change in drug dispensing. In particular, adherence was measured indirectly by comparing the number of pills left at the end of the prescribed treatment. Out of the 1185 patients included during 3 sessions of 4 consecutive weeks each, 907 patients experimented the personalized delivery and 278 were assigned to the control group, consistent with a 1/3 randomization-rate at the pharmacy level. 80% of eligible patients approved of the per-unit dispensing of their treatment. The initial packaging of the drugs did not match with the prescription in 60% of cases and per-unit dispensing reduced by 10% the number of pills supplied. 13.1% of patients declared that they threw away pills residuals instead of recycling-no differences between groups. Finally, per-unit dispensing appeared to improve adherence to antibiotic treatment (marginal effect 0.21, IC 95, 0.14-0.28). Supplying antibiotics per unit is not only beneficial in terms of a reduced number of pills to reimburse or for the environment (less pills wasted and non-recycled), but also has a positive and unexpected impact on adherence to treatment, and thus on both individual and public health.

  8. 'Massfunktionen' as limit conditions of an optimization scheme for the telecobalt therapy

    International Nuclear Information System (INIS)

    Kirsch, M.; Forth, E.; Schumann, E.

    1978-01-01

    The basic ideas of the 'Score-Funktionen-Modell' of Hope and his collaborators are used for the establishment of the first stage of an optimization scheme for the telecobalt therapy. The new 'Massfunktionen' for the telecobalt therapy are limit conditions for the criterion of the optimum, i.e. the dose distribution in a body section. The 'Massfunktionen' are an analytic registration of parameters for the dose distribution such as dose homogeneity in the focal region and sparing of the subcutaneous tissues, the radiosensitive organs and the sound surroundings of the tumor. The functions are derived from the dose conditions in the irradiated body section. At the actual stage of development of the optimization scheme, these functions allow to decide whether an irradiation scheme is acceptable or not. (orig.) [de

  9. [Dispensing prescriptions to persons affiliated with the Seguro Popular de Salud de México].

    Science.gov (United States)

    Garrido-Latorre, Francisco; Hernández-Llamas, Héctor; Gómez-Dantés, Octavio

    2008-01-01

    Measure and compare the percentage of prescriptions fully dispensed to persons with and without Popular Health Insurance (SPS in Spanish) who use ambulatory and general hospital services associated with the Mexico State Health Services (SESA in Spanish), and taking into account insurance status. SESA user satisfaction was also measured with respect to access to medication. Information for the study was taken from four surveys of SESA ambulatory and hospital units that included probabilistic samples with state representativity. Samples of ambulatory units were selected by stratification according to level of care and association to the SPS service network. The findings indicate that the percentage of prescriptions fully dispensed in SESA ambulatory units has improved, reaching approximately 90%, especially among those units offering services to persons affiliated with SPS. Nevertheless, these percentages continue to be lower than those of ambulatory units associated with social security institutions. Percentages of prescriptions fully dispensed have also improved in SESA hospital units, but continue to be relatively low. In nearly all states, as the percentage of prescriptions fully dispensed has increased, user satisfaction with access to medication has also improved. In 2006 more than 50% of the states had high levels of fully dispensed prescriptions among persons with SPS (> or =90%). The more significant problem exists among hospitals, since only 44% of users who received a prescription in SESA hospitals in 2006 had their prescriptions fully dispensed. This finding requires a review of SPS medication policies, which have favored highly prescribed low-cost medications at ambulatory services at the expense of higher cost and more therapeutically effective medications for hospital care, the latter having a greater impact on household budgets.

  10. Automated dose estimation for lost or damaged dosimeters

    International Nuclear Information System (INIS)

    Thompson, W.L.; Deininger, R.J.

    1988-01-01

    This paper reports that some dosimetry vendors will compute doses for their customers' lost/damaged dosimeters based upon an average of recent dosimeter readings. However, the vendors usually require authorization from the customer for each such occurrence. Therefore, the tedious task of keeping track of the overdue status of each missing dosimeter and constantly notifying the vendor is still present. Also, depending on the monthly variability of a given person's doses, it may be more valid to use the employee's average dose, his/her highest dose over a recent period, an average dose of other employees with similar job duties for that period, or the maximum permissible dose. Thus, the task of estimating doses for lost/damaged dosimeters cannot be delegated to dosimetry vendor. Instead, the radiation safety department must sue the data supplied by the vendor as input for performing estimates. The process is performed automatically at the Medical Center Hospital of Vermont using a personal computer and a relational database

  11. Applying a computer-aided scheme to detect a new radiographic image marker for prediction of chemotherapy outcome

    International Nuclear Information System (INIS)

    Wang, Yunzhi; Qiu, Yuchen; Thai, Theresa; Moore, Kathleen; Liu, Hong; Zheng, Bin

    2016-01-01

    To investigate the feasibility of automated segmentation of visceral and subcutaneous fat areas from computed tomography (CT) images of ovarian cancer patients and applying the computed adiposity-related image features to predict chemotherapy outcome. A computerized image processing scheme was developed to segment visceral and subcutaneous fat areas, and compute adiposity-related image features. Then, logistic regression models were applied to analyze association between the scheme-generated assessment scores and progression-free survival (PFS) of patients using a leave-one-case-out cross-validation method and a dataset involving 32 patients. The correlation coefficients between automated and radiologist’s manual segmentation of visceral and subcutaneous fat areas were 0.76 and 0.89, respectively. The scheme-generated prediction scores using adiposity-related radiographic image features significantly associated with patients’ PFS (p < 0.01). Using a computerized scheme enables to more efficiently and robustly segment visceral and subcutaneous fat areas. The computed adiposity-related image features also have potential to improve accuracy in predicting chemotherapy outcome

  12. Dose classification scheme for digital imaging techniques in diagnostic radiology

    International Nuclear Information System (INIS)

    Hojreh, A.

    2002-04-01

    Purpose: image quality in diagnostic radiology is determined in crucial extent by the signal-noise-ratio, which is proportional to the applied x-ray dose. Onward technological developments in the diagnostic radiology are therefore frequently connected with a dose increase, which subjectively is hardly or even not perceptible. The aim of this work was to define reproducible standards for image quality as a function of dose and expected therapeutical consequence in case of computed tomography of the paranasal sinuses and the upper and lower jaw (dental CT), whereby practical-clinical purposes are considered. Materials and methods: the image quality of computed tomography of the paranasal sinuses and dental CT was determined by standard deviation of the CT-numbers (pixel noise) in a region of interest of the phantom of American Association of Physicists in Medicine (AAPM phantom) and additionally in the patients CT images. The diagnostic quality of the examination was classified on the basis of patients CT images in three dose levels (low dose, standard dose and high dose). Results: the pixel noise of CT of the paranasal sinuses with soft tissue reconstruction amounts to 19.3 Hounsfield units (HU) for low dose, 8.8 HU for standard dose, and below 8 HU for high dose. The pixel noise of the dental CT with bone (high resolution) reconstruction amounts to 344 HU for low dose, 221 HU for standard dose, and below 200 HU for high dose. Suitable indications for low dose CT are the scanning of body regions with high contrast differences, like the bony delimitations of air-filled spaces of the facial bones, and radiological follow-up examinations with dedicated questions such as axis determination in dental implantology, as well as the images of objects with small diameter such as in case of children. The standard dose CT can be recommended for all cases, in which precise staging of the illness plays an indispensable role for the diagnosis and therapy planning. With high dose

  13. Indigenous development of automated metallographic sample preparation system

    International Nuclear Information System (INIS)

    Kulkarni, A.P.; Pandit, K.M.; Deshmukh, A.G.; Sahoo, K.C.

    2005-01-01

    Surface preparation of specimens for Metallographic studies on irradiated material involves a lot of remote handling of radioactive material by skilled manpower. These are laborious and man-rem intensive activities and put limitations on number of samples that can be prepared for the metallographic studies. To overcome these limitations, automated systems have been developed for surface preparation of specimens in PIE division. The system includes (i) Grinding and polishing stations (ii) Water jet cleaning station (iii) Ultrasonic cleaning stations (iv) Drying station (v) Sample loading and unloading station (vi) Dispenser for slurries and diluents and (vii) Automated head for movement of the sample holder disc from one station to other. System facilities the operator for programming/changing sequence of the sample preparations including remote changing of grinding/polishing discs from the stations. Two such systems have been installed and commissioned in Hot Cell for PIE Division. These are being used for preparation of irradiated samples from nuclear fuels and structural components. This development has increased the throughput of metallography work and savings in terms of (man-severts) radiation exposure to operators. This presentation will provide details of the challenges in undertaking this developmental work. (author)

  14. Pheromone dispensers, including organic polymer fibers, described in the crop protection literature: comparison of their innovation potential.

    Science.gov (United States)

    Hummel, Hans E; Langner, S S; Eisinger, M-T

    2013-01-01

    Pheromone dispensers, although known in a variety of different designs, are one of the few remaining technical bottlenecks along the way to a sustainable pheromone based strategy in integrated pest management (IPM). Mating disruption with synthetic pheromones is a viable pest management approach. Suitable pheromone dispensers for these mating disruption schemes, however, are lagging behind the general availability of pheromones. Specifically, there is a need for matching the properties of the synthetic pheromones, the release rates suitable for certain insect species, and the environmental requirements of specific crop management. The "ideal" dispenser should release pheromones at a constant but pre-adjustable rate, should be mechanically applicable, completely biodegradable and thus save the costs for recovering spent dispensers. These should be made from renewable, cheap organic material, be economically inexpensive, and be toxicologically and eco-toxicologically inert to provide satisfactory solutions for the needs of practicing growers. In favourable cases, they will be economically competitive with conventional pesticide treatments and by far superior in terms of environmental and eco-toxicological suitability. In the course of the last 40 years, mating disruption, a non-toxicological approach, provided proof for its potential in dozens of pest insects of various orders and families. Applications for IPM in many countries of the industrialized and developing world have been reported. While some dispensers have reached wide circulation, only few of the key performing parameters fit the above requirements ideally and must be approximated with some sacrifice in performance. A fair comparison of the innovation potential of currently available pheromone dispensers is attempted. The authors advance here the use of innovative electrospun organic fibers with dimensions in the "meso" (high nano- to low micrometer) region. Due to their unique multitude of adjustable

  15. Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose.

    Science.gov (United States)

    May, Matthias S; Kramer, Manuel R; Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael; Saake, Marc; Schmidt, Bernhard; Uder, Michael; Lell, Michael M

    2014-09-01

    Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDIvol. Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7-8%. TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality.

  16. Automated MAD and MIR structure solution

    International Nuclear Information System (INIS)

    Terwilliger, Thomas C.; Berendzen, Joel

    1999-01-01

    A fully automated procedure for solving MIR and MAD structures has been developed using a scoring scheme to convert the structure-solution process into an optimization problem. Obtaining an electron-density map from X-ray diffraction data can be difficult and time-consuming even after the data have been collected, largely because MIR and MAD structure determinations currently require many subjective evaluations of the qualities of trial heavy-atom partial structures before a correct heavy-atom solution is obtained. A set of criteria for evaluating the quality of heavy-atom partial solutions in macromolecular crystallography have been developed. These have allowed the conversion of the crystal structure-solution process into an optimization problem and have allowed its automation. The SOLVE software has been used to solve MAD data sets with as many as 52 selenium sites in the asymmetric unit. The automated structure-solution process developed is a major step towards the fully automated structure-determination, model-building and refinement procedure which is needed for genomic scale structure determinations

  17. TU-H-207A-09: An Automated Technique for Estimating Patient-Specific Regional Imparted Energy and Dose From TCM CT Exams Across 13 Protocols

    International Nuclear Information System (INIS)

    Sanders, J; Tian, X; Segars, P; Boone, J; Samei, E

    2016-01-01

    Purpose: To develop an automated technique for estimating patient-specific regional imparted energy and dose from tube current modulated (TCM) computed tomography (CT) exams across a diverse set of head and body protocols. Methods: A library of 58 adult computational anthropomorphic extended cardiac-torso (XCAT) phantoms were used to model a patient population. A validated Monte Carlo program was used to simulate TCM CT exams on the entire library of phantoms for three head and 10 body protocols. The net imparted energy to the phantoms, normalized by dose length product (DLP), and the net tissue mass in each of the scan regions were computed. A knowledgebase containing relationships between normalized imparted energy and scanned mass was established. An automated computer algorithm was written to estimate the scanned mass from actual clinical CT exams. The scanned mass estimate, DLP of the exam, and knowledgebase were used to estimate the imparted energy to the patient. The algorithm was tested on 20 chest and 20 abdominopelvic TCM CT exams. Results: The normalized imparted energy increased with increasing kV for all protocols. However, the normalized imparted energy was relatively unaffected by the strength of the TCM. The average imparted energy was 681 ± 376 mJ for abdominopelvic exams and 274 ± 141 mJ for chest exams. Overall, the method was successful in providing patientspecific estimates of imparted energy for 98% of the cases tested. Conclusion: Imparted energy normalized by DLP increased with increasing tube potential. However, the strength of the TCM did not have a significant effect on the net amount of energy deposited to tissue. The automated program can be implemented into the clinical workflow to provide estimates of regional imparted energy and dose across a diverse set of clinical protocols.

  18. Use of direct washing of chemical dispense nozzle for defect control

    Science.gov (United States)

    Linnane, Michael; Mack, George; Longstaff, Christopher; Winter, Thomas

    2006-03-01

    Demands for continued defect reduction in 300mm IC manufacturing are driving process engineers to examine all aspects of the chemical apply process for improvement. Historically, the defect contribution from photoresist apply nozzles has been minimized through a carefully controlled process of "dummy dispenses" to keep the photoresist in the tip "fresh" and remove any solidified material, a preventive maintenance regime involving periodic cleaning or replacing of the nozzles, and reliance on a pool of solvent within the nozzle storage block to keep the photoresist from solidifying at the nozzle tip. The industry standard has worked well for the most part but has limitations in terms of cost effectiveness and absolute defect elimination. In this study, we investigate the direct washing of the chemical apply nozzle to reduce defects seen on the coated wafer. Data is presented on how the direct washing of the chemical dispense nozzle can be used to reduce coating related defects, reduce material costs from the reduction of "dummy dispense", and can reduce equipment downtime related to nozzle cleaning or replacement.

  19. Microbiological quality of drinking water from dispensers in roadside restaurants of Bangladesh.

    Science.gov (United States)

    Moniruzzaman, M; Akter, S; Islam, M A; Mia, Z

    2011-01-15

    The microbiological status of water from dispensers in different roadside restaurants of Dhaka city and Savar area was analyzed in this study. Seven samples from Dhaka and 8 samples of Savar were checked. The heterotrophic plate count was in a range of 1.0 x 10(3) CFU mL(-1) to 2.0 x 10(4) CFU mL(-1) (from new bottles), 1.0 x 10(3) to 1.5 x 10(4) CFU mL(-1) (after dispensation), and 1.5 x 10(3) CFU mL(-1) to 1.0 x l0(5) CFU mL(-1) (from serving glass). In several of the samples, the heterotrophic plate count was higher than the count in water from new bottle or after dispensation, suggesting added contamination from the serving glass. 80% of the samples were contaminated with total and fecal coliform bacteria, which render these waters unacceptable for human consumption. The samples were found to contain gram negative bacteria like E coli, Shigella sp., Klebsiella sp., Enterobacter sp., Pseudomonas sp., and Salmonella sp., which are potential pathogens and thus pose a serious threat to public health. This study elucidates the importance of monitoring the bottling companies and the restaurants and put them under strict regulations to prevent future outbreak of any water borne diseases caused by consumption of dispensed water.

  20. All dispenser printed flexible 3D structured thermoelectric generators

    Science.gov (United States)

    Cao, Z.; Shi, J. J.; Torah, R. N.; Tudor, M. J.; Beeby, S. P.

    2015-12-01

    This work presents a vertically fabricated 3D thermoelectric generator (TEG) by dispenser printing on flexible polyimide substrate. This direct-write technology only involves printing of electrodes, thermoelectric active materials and structure material, which needs no masks to transfer the patterns onto the substrate. The dimension for single thermoelectric element is 2 mm × 2 mm × 0.5 mm while the distance between adjacent cubes is 1.2 mm. The polymer structure layer was used to support the electrodes which are printed to connect the top ends of the thermoelectric material and ensure the flexibility as well. The advantages and the limitations of the dispenser printed 3D TEGs will also be evaluated in this paper. The proposed method is potential to be a low-cost and scalable fabrication solution for TEGs.

  1. Automated electronic filter design

    CERN Document Server

    Banerjee, Amal

    2017-01-01

    This book describes a novel, efficient and powerful scheme for designing and evaluating the performance characteristics of any electronic filter designed with predefined specifications. The author explains techniques that enable readers to eliminate complicated manual, and thus error-prone and time-consuming, steps of traditional design techniques. The presentation includes demonstration of efficient automation, using an ANSI C language program, which accepts any filter design specification (e.g. Chebyschev low-pass filter, cut-off frequency, pass-band ripple etc.) as input and generates as output a SPICE(Simulation Program with Integrated Circuit Emphasis) format netlist. Readers then can use this netlist to run simulations with any version of the popular SPICE simulator, increasing accuracy of the final results, without violating any of the key principles of the traditional design scheme.

  2. Rational dispensing and use of artemether-lumefantrine during ...

    African Journals Online (AJOL)

    This was a prospective-descriptive study involving visits to 200 private retail pharmacies (using a mystery shopper) and interviewing pregnant women at the municipal public hospitals in Dar es Salaam, ... There is therefore a need for continuing training of drug dispensers regarding antimalarial drugs use in pregnancy.

  3. AUTOMATION OF CHAMPAGNE WINES PROCESS IN SPARKLING WINE PRESSURE TANK

    Directory of Open Access Journals (Sweden)

    E. V. Lukyanchuk

    2016-08-01

    Full Text Available The wine industry is now successfully solved the problem for the implementation of automation receiving points of grapes, crushing and pressing departments installation continuous fermentation work, blend tanks, production lines ordinary Madeira continuously working plants for ethyl alcohol installations champagne wine in continuous flow, etc. With the development of automation of technological progress productivity winemaking process develops in the following areas: organization of complex avtomatization sites grape processing with bulk transportation of the latter; improving the quality and durability of wines by the processing of a wide applying wine cold and heat, as well as technical and microbiological control most powerful automation equipment; the introduction of automated production processes of continuous technical champagne, sherry wine and cognac alcohol madery; the use of complex automation auxiliary production sites (boilers, air conditioners, refrigeration unitsand other.; complex avtomatization creation of enterprises, and sites manufactory bottling wines. In the wine industry developed more sophisticated schemes of automation and devices that enable the transition to integrated production automation, will create, are indicative automated enterprise serving for laboratories to study of the main problems of automation of production processes of winemaking.

  4. The role of pharmacists and emergency contraception: Are pharmacists' perceptions of emergency contraception predictive of their dispensing practices?

    Science.gov (United States)

    Richman, Alice R; Daley, Ellen M; Baldwin, Julie; Kromrey, Jeff; O'Rourke, Kathleen; Perrin, Kay

    2012-10-01

    Pharmacists can play a critical role in the access to emergency contraception (EC). We assessed if knowledge and attitudes were predictive of EC dispensing among a statewide sample of Florida pharmacists, who have legal authority to refuse to dispense medications. In 2008, surveys were mailed to a random sample of 1264 pharmacists registered with the Florida Board of Pharmacy. Data from 272 pharmacists (22% response rate) were analyzed using bivariate and multivariate logistic regression. Fifty-six percent of respondents incorrectly answered that EC causes birth defects, and 46% replied that it causes abortion. Only 22% said that EC can be purchased in advance of need. Many felt uncomfortable dispensing to adolescents (61%) and men (58%). Knowledge about EC was the most important predictor of dispensing [odds ratio (OR)=1.57, 95% confidence interval (CI) 1.22-2.03]. In particular, pharmacists who reported that EC does not act as an abortifacient were more likely to dispense it (OR=4.64, 95% CI 2.15-10.00). Correct information about EC was the most important predictor of pharmacists' dispensing EC. To expand availability of EC, pharmacists will have to become better informed. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Maintaining Microclimates during Nanoliter Chemical Dispensations Using Custom-Designed Source Plate Lids.

    Science.gov (United States)

    Foley, Bryan J; Drozd, Ashley M; Bollard, Mary T; Laspina, Denise; Podobedov, Nikita; Zeniou, Nicholas; Rao, Anjali S; Andi, Babak; Jackimowicz, Rick; Sweet, Robert M; McSweeney, Sean; Soares, Alexei S

    2016-02-01

    A method is described for using custom snap-on lids to protect chemicals in microtiter plates from evaporation and contamination. The lids contain apertures (diameter 1.5, 1.0, or 0.5 mm) through which the chemical building blocks can be transferred. The lid with 0.5 mm apertures was tested using a noncontact acoustic liquid handler; the 1.0 and 1.5 mm lids were tested using two tip-based liquid handlers. All of the lids reduced the rate at which solvents evaporated to room air, and greatly reduced the rate of contamination by water and oxygen from room air. In steady-state measurements, the lids reduced the rate of evaporation of methanol, 1-hexene, and water by 33% to 248%. In cycled experiments, the contamination of aqueous solvent with oxygen was reduced below detectability and the rate at which DMSO engorged atmospheric water was reduced by 81%. Our results demonstrate that the lids preserve the integrity of air-sensitive reagents during the time needed for different types of liquid handlers to perform dispensations. Controlling degradation and evaporation of chemical building blocks exposed to the atmosphere is increasingly useful as the reagent volume is reduced by advances in liquid handling technology, such as acoustic droplet ejection. © 2015 Society for Laboratory Automation and Screening.

  6. Necessity of rethinking oral pediatric formulations

    DEFF Research Database (Denmark)

    Bar-Shalom, Daniel

    2014-01-01

    by all patient groups, is needed, and an automated compounding concept is proposed. The finishing of the formulation is done at the dispensing pharmacy using an automated process. The individual components (pudding-like carrier, microencapsulated drug, and the dispensing robot and its software...

  7. Optimization of the fractionated irradiation scheme considering physical doses to tumor and organ at risk based on dose–volume histograms

    Energy Technology Data Exchange (ETDEWEB)

    Sugano, Yasutaka [Graduate School of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0812 (Japan); Mizuta, Masahiro [Laboratory of Advanced Data Science, Information Initiative Center, Hokkaido University, Kita-11, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0811 (Japan); Takao, Seishin; Shirato, Hiroki; Sutherland, Kenneth L. [Department of Radiation Medicine, Graduate School of Medicine, Hokkaido University, Kita-15, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-8638 (Japan); Date, Hiroyuki, E-mail: date@hs.hokudai.ac.jp [Faculty of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0812 (Japan)

    2015-11-15

    Purpose: Radiotherapy of solid tumors has been performed with various fractionation regimens such as multi- and hypofractionations. However, the ability to optimize the fractionation regimen considering the physical dose distribution remains insufficient. This study aims to optimize the fractionation regimen, in which the authors propose a graphical method for selecting the optimal number of fractions (n) and dose per fraction (d) based on dose–volume histograms for tumor and normal tissues of organs around the tumor. Methods: Modified linear-quadratic models were employed to estimate the radiation effects on the tumor and an organ at risk (OAR), where the repopulation of the tumor cells and the linearity of the dose-response curve in the high dose range of the surviving fraction were considered. The minimization problem for the damage effect on the OAR was solved under the constraint that the radiation effect on the tumor is fixed by a graphical method. Here, the damage effect on the OAR was estimated based on the dose–volume histogram. Results: It was found that the optimization of fractionation scheme incorporating the dose–volume histogram is possible by employing appropriate cell surviving models. The graphical method considering the repopulation of tumor cells and a rectilinear response in the high dose range enables them to derive the optimal number of fractions and dose per fraction. For example, in the treatment of prostate cancer, the optimal fractionation was suggested to lie in the range of 8–32 fractions with a daily dose of 2.2–6.3 Gy. Conclusions: It is possible to optimize the number of fractions and dose per fraction based on the physical dose distribution (i.e., dose–volume histogram) by the graphical method considering the effects on tumor and OARs around the tumor. This method may stipulate a new guideline to optimize the fractionation regimen for physics-guided fractionation.

  8. Occurrence of heterotrophic and coliform bacteria in liquid hand soaps from bulk refillable dispensers in public facilities.

    Science.gov (United States)

    Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P

    2011-03-01

    The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.

  9. A Fully Automated High-Throughput Zebrafish Behavioral Ototoxicity Assay.

    Science.gov (United States)

    Todd, Douglas W; Philip, Rohit C; Niihori, Maki; Ringle, Ryan A; Coyle, Kelsey R; Zehri, Sobia F; Zabala, Leanne; Mudery, Jordan A; Francis, Ross H; Rodriguez, Jeffrey J; Jacob, Abraham

    2017-08-01

    Zebrafish animal models lend themselves to behavioral assays that can facilitate rapid screening of ototoxic, otoprotective, and otoregenerative drugs. Structurally similar to human inner ear hair cells, the mechanosensory hair cells on their lateral line allow the zebrafish to sense water flow and orient head-to-current in a behavior called rheotaxis. This rheotaxis behavior deteriorates in a dose-dependent manner with increased exposure to the ototoxin cisplatin, thereby establishing itself as an excellent biomarker for anatomic damage to lateral line hair cells. Building on work by our group and others, we have built a new, fully automated high-throughput behavioral assay system that uses automated image analysis techniques to quantify rheotaxis behavior. This novel system consists of a custom-designed swimming apparatus and imaging system consisting of network-controlled Raspberry Pi microcomputers capturing infrared video. Automated analysis techniques detect individual zebrafish, compute their orientation, and quantify the rheotaxis behavior of a zebrafish test population, producing a powerful, high-throughput behavioral assay. Using our fully automated biological assay to test a standardized ototoxic dose of cisplatin against varying doses of compounds that protect or regenerate hair cells may facilitate rapid translation of candidate drugs into preclinical mammalian models of hearing loss.

  10. Automation of analytical systems in power cycles

    International Nuclear Information System (INIS)

    Staub Lukas

    2008-01-01

    'Automation' is a widely used term in instrumentation and is often applied to signal exchange, PLC and SCADA systems. Common use, however, does not necessarily described autonomous operation of analytical devices. We define an automated analytical system as a black box with an input (sample) and an output (measured value). In addition we need dedicated status lines for assessing the validities of the input for our black box and the output for subsequent systems. We will discuss input parameters, automated analytical processes and output parameters. Further considerations will be given to signal exchange and integration into the operating routine of a power plant. Local control loops (chemical dosing) and the automation of sampling systems are not discussed here. (author)

  11. The Automated System for Identification of License Plates of Cars

    Directory of Open Access Journals (Sweden)

    FRATAVCHAN, V.

    2008-04-01

    Full Text Available The paper focuses on the automated traffic rule control system. It examines the basic scheme of the system, basic constituents, principles of constituent interactions, search methods of moving objects, localization, and identification of the license plate.

  12. SU-D-16A-02: A Novel Methodology for Accurate, Semi-Automated Delineation of Oral Mucosa for Radiation Therapy Dose-Response Studies

    International Nuclear Information System (INIS)

    Dean, J; Welsh, L; Gulliford, S; Harrington, K; Nutting, C

    2014-01-01

    Purpose: The significant morbidity caused by radiation-induced acute oral mucositis means that studies aiming to elucidate dose-response relationships in this tissue are a high priority. However, there is currently no standardized method for delineating the mucosal structures within the oral cavity. This report describes the development of a methodology to delineate the oral mucosa accurately on CT scans in a semi-automated manner. Methods: An oral mucosa atlas for automated segmentation was constructed using the RayStation Atlas-Based Segmentation (ABS) module. A radiation oncologist manually delineated the full surface of the oral mucosa on a planning CT scan of a patient receiving radiotherapy (RT) to the head and neck region. A 3mm fixed annulus was added to incorporate the mucosal wall thickness. This structure was saved as an atlas template. ABS followed by model-based segmentation was performed on four further patients sequentially, adding each patient to the atlas. Manual editing of the automatically segmented structure was performed. A dose comparison between these contours and previously used oral cavity volume contours was performed. Results: The new approach was successful in delineating the mucosa, as assessed by an experienced radiation oncologist, when applied to a new series of patients receiving head and neck RT. Reductions in the mean doses obtained when using the new delineation approach, compared with the previously used technique, were demonstrated for all patients (median: 36.0%, range: 25.6% – 39.6%) and were of a magnitude that might be expected to be clinically significant. Differences in the maximum dose that might reasonably be expected to be clinically significant were observed for two patients. Conclusion: The method developed provides a means of obtaining the dose distribution delivered to the oral mucosa more accurately than has previously been achieved. This will enable the acquisition of high quality dosimetric data for use in

  13. Analyzing implementation dynamics using theory-driven evaluation principles: lessons learnt from a South African centralized chronic dispensing model.

    Science.gov (United States)

    Magadzire, Bvudzai Priscilla; Marchal, Bruno; Mathys, Tania; Laing, Richard O; Ward, Kim

    2017-12-04

    Centralized dispensing of essential medicines is one of South Africa's strategies to address the shortage of pharmacists, reduce patients' waiting times and reduce over-crowding at public sector healthcare facilities. This article reports findings of an evaluation of the Chronic Dispensing Unit (CDU) in one province. The objectives of this process evaluation were to: (1) compare what was planned versus the actual implementation and (2) establish the causal elements and contextual factors influencing implementation. This qualitative study employed key informant interviews with the intervention's implementers (clinicians, managers and the service provider) [N = 40], and a review of policy and program documents. Data were thematically analyzed by identifying the main influences shaping the implementation process. Theory-driven evaluation principles were applied as a theoretical framework to explain implementation dynamics. The overall participants' response about the CDU was positive and the majority of informants concurred that the establishment of the CDU to dispense large volumes of medicines is a beneficial strategy to address healthcare barriers because mechanical functions are automated and distribution of medicines much quicker. However, implementation was influenced by the context and discrepancies between planned activities and actual implementation were noted. Procurement inefficiencies at central level caused medicine stock-outs and affected CDU activities. At the frontline, actors were aware of the CDU's implementation guidelines regarding patient selection, prescription validity and management of non-collected medicines but these were adapted to accommodate practical realities and to meet performance targets attached to the intervention. Implementation success was a result of a combination of 'hardware' (e.g. training, policies, implementation support and appropriate infrastructure) and 'software' (e.g. ownership, cooperation between healthcare

  14. A modified thrombolytic scheme for the treatment of cerebral venous sinus thrombosis

    International Nuclear Information System (INIS)

    Zhao Lin; Shi Jiancheng; Liu Zengpin; Li Linfang; Wang Zhihong; Wang Tiegang; Zhou Cunhe

    2009-01-01

    Objective: To discuss the curative effect and safety of a modified thrombolytic scheme in the treatment of cerebral sinus thrombosis. The new scheme adopts unremitting pump infusion of microdose urokinase (100,000 IU/24 h) into the cerebral venous sinus. Methods: The new therapeutic scheme was conducted in 21 patients with cerebral sinus thrombosis. Mechanical disruption of the thrombus was applied by moving the micro guidewire back and forth in the thrombus site, and unremitting pump infusion of urokanase for 48-96 hours with the lowest dose of 100,000 u/24 h was used. A follow-up of 6-12 months was made. Results: Recanalization of the occluded cerebral venous sinus was obtained in all 21 patients. The total urokinase dose of 100,000 u/24 h was used in 12 patients. For the other 9 patients the urokinase dose was 100,000 u/24 h in the first 48 hours, then the dose was increased to 250,000 u/24 h. No serious complications occurred. All patients showed a good prognosis. Conclusion: For the treatment of cerebral sinus thrombosis, this modified thrombolytic scheme is more safe and effective with less hemorrhage as compared to the classical one, since it may avoid certain complications caused by the use of large dose of thrombolytic drug . (authors)

  15. Automated structure solution, density modification and model building.

    Science.gov (United States)

    Terwilliger, Thomas C

    2002-11-01

    The approaches that form the basis of automated structure solution in SOLVE and RESOLVE are described. The use of a scoring scheme to convert decision making in macromolecular structure solution to an optimization problem has proven very useful and in many cases a single clear heavy-atom solution can be obtained and used for phasing. Statistical density modification is well suited to an automated approach to structure solution because the method is relatively insensitive to choices of numbers of cycles and solvent content. The detection of non-crystallographic symmetry (NCS) in heavy-atom sites and checking of potential NCS operations against the electron-density map has proven to be a reliable method for identification of NCS in most cases. Automated model building beginning with an FFT-based search for helices and sheets has been successful in automated model building for maps with resolutions as low as 3 A. The entire process can be carried out in a fully automatic fashion in many cases.

  16. Experimental Study on Intelligent Control Scheme for Fan Coil Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Yanfeng Li

    2013-01-01

    Full Text Available An intelligent control scheme for fan coil air-conditioning systems has been put forward in order to overcome the shortcomings of the traditional proportion-integral-derivative (PID control scheme. These shortcomings include the inability of anti-interference and large inertia. An intelligent control test rig of fan coil air-conditioning system has been built, and MATLAB/Simulink dynamics simulation software has been adopted to implement the intelligent control scheme. A software for data exchange has been developed to combine the intelligence control system and the building automation (BA system. Experimental tests have been conducted to investigate the effectiveness of different control schemes including the traditional PID control, fuzzy control, and fuzzy-PID control for fan coil air-conditioning system. The effects of control schemes have been compared and analyzed in robustness, static and dynamic character, and economy. The results have shown that the developed data exchange interface software can induce the intelligent control scheme of the BA system more effectively. Among the proposed control strategies, fuzzy-PID control scheme which has the advantages of both traditional PID and fuzzy schemes is the optimal control scheme for the fan coil air-conditioning system.

  17. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  18. Reformulation of controlled-release oxycodone and pharmacy dispensing patterns near the US-Canada border.

    Science.gov (United States)

    Gomes, Tara; Paterson, J Michael; Juurlink, David N; Dhalla, Irfan A; Mamdani, Muhammad M

    2012-01-01

    In August 2010, a tamper-resistant formulation of controlled-release oxycodone (OxyContin-OP) was introduced in the United States but not in Canada. Our objective was to determine whether introduction of OxyContin-OP in the United States influenced prescription volumes for the original controlled-release oxycodone formulation (OxyContin) at Canadian pharmacies near the international border. We conducted a population-based, serial, cross-sectional study of prescriptions dispensed from pharmacies in the 3 cities with the highest volume of US-Canada border crossings in Ontario: Niagara Falls, Windsor and Sarnia. We analyzed data on all outpatient prescriptions for OxyContin dispensed by Canadian pharmacies near each border crossing between 2010 Apr. 1 and 2012 Feb. 29. We calculated and compared monthly prescription rates, adjusted per 1000 population and stratified by tablet strength. The number of tablets dispensed near 4 border crossings in the 3 Canadian cities remained stable over the study period. However, the rate of dispensing at pharmacies near the Detroit-Windsor Tunnel increased roughly 4-fold between August 2010 and February 2011, from 505 to 1969 tablets per 1000 population. By April 2011, following warnings to prescribers and pharmacies regarding drug-seeking behaviour, the dispensing rate declined to 1683 tablets per 1000 population in this area. By November 2011, the rate had returned to levels observed in early 2010. Our analyses suggest that 242 075 excess OxyContin tablets were dispensed near the Detroit-Windsor Tunnel between August 2010 and October 2011. Prescribing of the original formulation of controlled-release oxycodone rose substantially near a major international border crossing following the introduction of a tamper-resistant formulation in the United States. It is possible that the restriction of this finding to the area surrounding the Detroit-Windsor Tunnel reflects specific characteristics of this border crossing, including its high

  19. E85 Dispenser Study

    Energy Technology Data Exchange (ETDEWEB)

    Moriarty, K.; Johnson, C.; Sears, T.; Bergeron, P.

    2009-12-01

    This study reviews E85 dispensing infrastructure advances and issues and evaluates the geographic concentration of flexible fuel vehicles (FFVs), E85 stations, ethanol production facilities, and E85 suppliers. Costs, space, financial incentives, and barriers to adding E85 fueling equipment at existing stations are also assessed. This study found that E85 is increasingly available in the U.S. in half of the states; however, the other half have minimal or no E85 fueling options. Despite these gains, E85 is only available at 1% of U.S. gasoline stations. Ethanol production reached 9.5 billion gallons in 2008, but less than 1% is consumed as E85. FFVs have not reached a significant concentration in any county, metropolitan area, or state.

  20. Space station automation study. Automation requirements derived from space manufacturing concepts. Volume 1: Executive summary

    Science.gov (United States)

    1984-01-01

    The two manufacturing concepts developed represent innovative, technologically advanced manufacturing schemes. The concepts were selected to facilitate an in depth analysis of manufacturing automation requirements in the form of process mechanization, teleoperation and robotics, and artificial intelligence. While the cost effectiveness of these facilities has not been analyzed as part of this study, both appear entirely feasible for the year 2000 timeframe. The growing demand for high quality gallium arsenide microelectronics may warrant the ventures.

  1. Exposing exposure: enhancing patient safety through automated data mining of nuclear medicine reports for quality assurance and organ dose monitoring.

    Science.gov (United States)

    Ikuta, Ichiro; Sodickson, Aaron; Wasser, Elliot J; Warden, Graham I; Gerbaudo, Victor H; Khorasani, Ramin

    2012-08-01

    To develop and validate an open-source informatics toolkit capable of creating a radiation exposure data repository from existing nuclear medicine report archives and to demonstrate potential applications of such data for quality assurance and longitudinal patient-specific radiation dose monitoring. This study was institutional review board approved and HIPAA compliant. Informed consent was waived. An open-source toolkit designed to automate the extraction of data on radiopharmaceuticals and administered activities from nuclear medicine reports was developed. After iterative code training, manual validation was performed on 2359 nuclear medicine reports randomly selected from September 17, 1985, to February 28, 2011. Recall (sensitivity) and precision (positive predictive value) were calculated with 95% binomial confidence intervals. From the resultant institutional data repository, examples of usage in quality assurance efforts and patient-specific longitudinal radiation dose monitoring obtained by calculating organ doses from the administered activity and radiopharmaceutical of each examination were provided. Validation statistics yielded a combined recall of 97.6% ± 0.7 (95% confidence interval) and precision of 98.7% ± 0.5. Histograms of administered activity for fluorine 18 fluorodeoxyglucose and iodine 131 sodium iodide were generated. An organ dose heatmap which displays a sample patient's dose accumulation from multiple nuclear medicine examinations was created. Large-scale repositories of radiation exposure data can be extracted from institutional nuclear medicine report archives with high recall and precision. Such repositories enable new approaches in radiation exposure patient safety initiatives and patient-specific radiation dose monitoring.

  2. Can formalizing links among community health workers, accredited drug dispensing outlet dispensers, and health facility staff increase their collaboration to improve prompt access to maternal and child care? A qualitative study in Tanzania.

    Science.gov (United States)

    Dillip, Angel; Kimatta, Suleiman; Embrey, Martha; Chalker, John C; Valimba, Richard; Malliwah, Mariam; Meena, John; Lieber, Rachel; Johnson, Keith

    2017-06-19

    In Tanzania, progress toward achieving the 2015 Millennium Development Goals for maternal and newborn health was slow. An intervention brought together community health workers, health facility staff, and accredited drug dispensing outlet (ADDO) dispensers to improve maternal and newborn health through a mechanism of collaboration and referral. This study explored barriers, successes, and promising approaches to increasing timely access to care by linking the three levels of health care provision. The study was conducted in the Kibaha district, where we applied qualitative approaches with in-depth interviews and focus group discussions. In-depth interview participants included retail drug shop dispensers (36), community health workers (45), and health facility staff members (15). We conducted one focus group discussion with district officials and four with mothers of newborns and children under 5 years old. Relationships among the three levels of care improved after the linkage intervention, especially for ADDO dispensers and health facility staff who previously had no formal communication pathway. The study participants perceptions of success included improved knowledge of case management and relationships among the three levels of care, more timely access to care, increased numbers of patients/customers, more meetings between community health workers and health facility staff, and a decrease in child and maternal mortality. Reported challenges included stock-outs of medicines at the health facility, participating ADDO dispensers who left to work in other regions, documentation of referrals, and lack of treatment available at health facilities on the weekend. The primary issue that threatens the sustainability of the intervention is that local council health management team members, who are responsible for facilitating the linkage, had not made any supervision visits and were therefore unaware of how the program was running. The study highlights the benefits of

  3. Surface contamination of counting tools after mock dispensing of cyclophosphamide in a simulated outpatient pharmacy.

    Science.gov (United States)

    Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A

    2018-01-01

    Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more prescriptions leads to trays having contamination that surpasses the threshold at which worker exposure may be increased. Pharmacies should consider devoting a separate tray to cyclophosphamide tablets, as cross-contamination could occur with other drugs and the efficacy of decontamination methods is unclear. Employee exposure could be minimized with the use

  4. The knowledge of emergency contraception and dispensing practices of Patent Medicine Vendors in South West Nigeria.

    Science.gov (United States)

    Fayemi, Mojisola M; Oduola, Olufemi L; Ogbuji, Queen C; Osinowo, Kehinde A; Oyewo, Adejoke E; Osiberu, Olabimpe M

    2010-09-01

    Patent Medicine Vendors (PMVs) can play a critical role in increasing access to emergency contraceptive pills (ECPs) in developing countries, but few studies have examined their knowledge and dispensing practices. Using cluster sampling, the authors selected and interviewed 97 PMVs (60.8 per cent female) in Oyo and Ogun States of Nigeria to assess their knowledge, dispensing practices, and referral for ECPs. About one-third (27.8 per cent) of respondents were not aware of ECPs, and only half knew that ECPs could prevent pregnancy. Forty per cent had ever dispensed ECPs. Reasons proffered by those who do not dispense ECPs included barriers from the State Ministry of Health, police, other regulatory agencies, and religious beliefs. Only 50.5 per cent have referral arrangements for clients. Strategies to increase access to ECPs through PMVs include training on counseling techniques and referral, effective government regulation, and community involvement. Where unsafe abortion is a major cause of maternal mortality, these strategies offer protection for many women in the future.

  5. College Cafeteria Signage Increases Water Intake but Water Position on the Soda Dispenser Encourages More Soda Consumption.

    Science.gov (United States)

    Montuclard, Astrid Linn; Park-Mroch, Jennifer; O'Shea, Amy M J; Wansink, Brian; Irvin, Jill; Laroche, Helena H

    2017-10-01

    To evaluate the effects of improved water location visibility and water dispenser position on the soda dispenser on undergraduate students' beverage choices. Two focus groups with pilot intervention surveys before and after, adding a small sign above the soda dispensers' water button for 6 weeks in a large US university's all-you-can-eat, prepaid dining hall (measured with chi-square tests and logistic and ordinal logistic regression). Focus groups included 15 students. Survey participants included 357 students before and 301 after the intervention. After the intervention, more students reported ever having drunk water with the meal (66.4% to 77.0%; P = .003) and water consumption frequency increased (P = .005). Postintervention, the odds of drinking water increased by 1.57. Preference for other drinks was the main reason for not drinking water. A total of 59% of students had ever changed their preference from water to soda. The clear indication of the water's location increased students' reported water consumption. Further investigation is needed into how a non-independent water dispenser influences students' beverage choice. Clearly labeled, independent water dispensers are recommended. Copyright © 2017 Society for Nutrition Education and Behavior. All rights reserved.

  6. The challenge of responsible dispensing: formal education versus professional practice

    Directory of Open Access Journals (Sweden)

    Nadine Judith Bezzegh

    2011-03-01

    Full Text Available The aim of the present study was to evaluate the education of Pharmaceutical Technicians for the activity of responsible dispensing. Based on a questionnaire with open and closed questions, the study sought to characterize the students, identify knowledge and attitudes regarding the Rational Use of Medications while addressing the limits and possibilities of professional and ethical dispensing in practice. In addition, a group dynamics session - focus group - was held as a forum for debate on responsible dispensing. The results showed that students tended to be mature, currently employed and were predominately women. Displaying adequate knowledge on Rational Use of Medications and of the corresponding legislation, the students reported difficulties exercising compatible practice. While the diagnosis pointed to the need for student preparation to enable ethical dispensing, the Focus Group highlighted the possibility for inclusion of a forum for reflection and debate on the ethics of dispensing as part of the Pharmaceutical Technician training.O presente trabalho tem como proposta avaliar a formação do Técnico em Farmácia para o exercício da dispensação responsável. A partir de um questionário com perguntas fechadas e abertas, o estudo envolveu a caracterização dos alunos, a identificação de conhecimentos e atitudes em relação ao Uso Racional dos Medicamentos com vistas ao delineamento dos limites e possibilidades do exercício profissional ético na dispensação. Além disso, foi realizada uma dinâmica grupal - grupo focal - com o objetivo de apreciar a constituição de um espaço de reflexão sobre a dispensação responsável. Os resultados evidenciaram um alunato de maior idade, inserido no mercado de trabalho e predominância de mulheres. Dispondo de conhecimento adequado sobre o Uso Racional dos Medicamentos e da legislação correspondente os alunos fazem referência às dificuldades no exercício de uma pr

  7. Design of a new non-sterile glove-dispensing unit to reduce touch-based contamination

    Directory of Open Access Journals (Sweden)

    Jennifer R Amos

    2014-06-01

    Full Text Available Background Despite best efforts by healthcare providers to sterilise their hands through hand washing prior to touching medical equipment and patients, bacteria are still present and can be spread through physical contact. We aimed to reduce the spread of touch-induced and airborne bacteria and virus spreading by using a touch-free glove-dispensing system that minimally exposes gloves in the box to air. Method The team met multiple times to undertake early prototyping and present ideas for the design. We experimented with folding gloves in varying patterns, similar to facial tissue-dispensing boxes, and tried several methods of opening/closing the glove box to determine the most effective way to access gloves with the least amount of physical contact. We considered the user experience and obtained user feedback after each design iteration. Results Ultimately, we decided on a vertically oriented box with optional holes for dispensing a glove on the side of the box or on the bottom by means of the pull-down drawer mechanism. This system will dispense a single glove at a time to the user with the option of using a pull-down drawer trigger to decrease the likelihood of physical contact with unused gloves. Both methods dispense a single glove. Conclusion: By reducing physical contact between the healthcare practitioner and the gloves, we are potentially reducing the spread of bacteria. This glove box design ensures that gloves are not exposed to the air in the clinic or hospital setting, thereby further reducing spread of airborne germs. This could assist in decreasing the risk of nosocomial infections in healthcare settings.

  8. Isolation of Raoultella planticola from refillable antimicrobial liquid soap dispensers in a dental setting.

    Science.gov (United States)

    Momeni, Stephanie S; Tomlin, Nancy; Ruby, John D

    2015-04-01

    Liquid antimicrobial soaps are commonly used in the dental health care setting for hand washing to minimize the potential spread of infectious agents to health care workers and patients. The purpose of the current study was to evaluate possible bacterial contamination of antimicrobial liquid soap dispensers located in 2 institutional comprehensive dental care clinics. Fourteen soap dispensers and 16 original stock containers were sampled. A 1-milliliter aliquot was diluted in 10 mL of phosphate buffer (Tween-80; Acros). Serial dilutions were plated in duplicate on neutralizing agar and incubated for 7 days. Molecular identification was performed using 500 base pair comparisons of 16S ribosomal ribonucleic acid sequencing. Taq polymerase chain reaction was performed with sequence-specific primers for Raoultella species. Bacterial growth was observed at 18 hours for 57% (8 of 14) of soap dispenser samples. Bacterial densities ranged from 4 × 10(2) to 6 × 10(9) colony-forming units per milliliter. Original commercial containers exhibited no growth. Isolates were identified as Raoultella (Klebsiella) planticola. This is the first study to the authors' knowledge indicating recovery of R. planticola from antimicrobial liquid soap dispensers. R. planticola is a recognized environmental opportunistic pathogen that potentially poses a health concern. These findings indicate compliance problems with infection prevention recommendations and support the US Centers for Disease Control and Prevention's recommendation that dispensers should not be topped off. High bacterial loads of R. planticola are inconsistent with infection control practices and are a concern because transmission and possible infection to the health care worker or the patient may occur. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  9. Automated process control system for heat-treating nuclear power station parts

    International Nuclear Information System (INIS)

    Afanasiadi, N.G.; Demin, V.P.; Launin, B.N.

    1984-01-01

    The basic factors determining the need for an automated process control system (APCS) are discussed, as are system requirements. The basic tasks solved by the system are discussed. The functional scheme for a decentralized, two-level APCS is given

  10. Raw Milk Hygiene at Local Markets and Automatic Milk Dispenser Machines

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available In Romania, direct sales of raw milk to the final consumer is developed based on the local regulations. These are in accordance to European Regulation that must meet some quality requirements for the total number of germs, somatic cells, without antibiotics, coming from healthy animals who did not suffer from diseases that can be transmitted to humans through milk. Raw milk is sold in Romania in local markets and by automatic milk dispenser machines. Based on these regulations, a study regarding the quality and security to human health of raw milk was conducted on the commercialized milk in local markets and automatic milk dispensers. During May-June 2014 samples of raw milk were collected from Cluj-Napoca local markets and automatic milk dispensers. All samples were kept to refrigeration conditions until the moment of analyze which took place at the sampling day. The following parameters were taken into account: fat content, protein, casein, lactose, nonfat dry matter, pH, milk freezing point, added water, antibiotics residues, milk urea, number of germ cells and somatic cells. All obtained results were verified by the validated methods applied. Our research can be forward conducted in order to verify the hygiene and composition of milk from the whole dairy chain. 

  11. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Ostermeyer, Christiane

    2014-01-01

    Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted Achromobacter species 3, when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%). Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation. Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential. PMID:24653973

  12. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2014-03-01

    Full Text Available [english] Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted , when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%. Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation.Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential.

  13. MVO Automation Platform: Addressing Unmet Needs in Clinical Laboratories with Microcontrollers, 3D Printing, and Open-Source Hardware/Software.

    Science.gov (United States)

    Iglehart, Brian

    2018-05-01

    Laboratory automation improves test reproducibility, which is vital to patient care in clinical laboratories. Many small and specialty laboratories are excluded from the benefits of automation due to low sample number, cost, space, and/or lack of automation expertise. The Minimum Viable Option (MVO) automation platform was developed to address these hurdles and fulfill an unmet need. Consumer 3D printing enabled rapid iterative prototyping to allow for a variety of instrumentation and assay setups and procedures. Three MVO versions have been produced. MVOv1.1 successfully performed part of a clinical assay, and results were comparable to those of commercial automation. Raspberry Pi 3 Model B (RPI3) single-board computers with Sense Hardware Attached on Top (HAT) and Raspberry Pi Camera Module V2 hardware were remotely accessed and evaluated for their suitability to qualify the latest MVOv1.2 platform. Sense HAT temperature, barometric pressure, and relative humidity sensors were stable in climate-controlled environments and are useful in identifying appropriate laboratory spaces for automation placement. The RPI3 with camera plus digital dial indicator logged axis travel experiments. RPI3 with camera and Sense HAT as a light source showed promise when used for photometric dispensing tests. Individual well standard curves were necessary for well-to-well light and path length compensations.

  14. Automation of data acquisition in electron crystallography.

    Science.gov (United States)

    Cheng, Anchi

    2013-01-01

    General considerations for using automation software for acquiring high-resolution images of 2D crystals under low-dose conditions are presented. Protocol modifications specific to this application in Leginon are provided.

  15. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Barker, K.; Johnston, J.; Stinchcomb, R.; Tarman, B.; Ice, R.D.

    1983-01-01

    In the last five years, the practice of nuclear medicine has undergone changes due to the advent of new imaging technologies and radiopharmaceuticals. These changes have had an impact upon the number and the type of radiopharmaceuticals dispensed in centralized nuclear pharmacies. With the advent of Computerized Axial Tomography Scanners (CAT), sophistication and wider acceptance of the Ultrasound imaging modality, nuclear medicine has had to change directions from utilizing radiopharmaceuticals for static organ imaging to functional type imaging and to resort to the use of new radiopharmaceuticals or to find other uses for the existing radiopharmaceuticals. The following trends in radiopharmaceutical dispensing in a regional nuclear pharmacy are evident: Brain procedures have declined by about 67% while nuclear cardiology studies have increased by over 2000%. Bone scans have increased by 72% while liver, renal and lung studies have shown no significant increase. These changes will continue as the practice of nuclear medicine concentrates more on functional studies and relegates other studies to newer imaging modalities

  16. Exceptional circumstance drug dispensing: history and expenditures of the Brazilian Ministry of Health.

    Science.gov (United States)

    Carias, Claudia Mezleveckas; Vieira, Fabíola Sulpino; Giordano, Carlos V; Zucchi, Paola

    2011-04-01

    To describe the technical aspects of the Exceptional Circumstance Drug Dispensing Program of the Brazilian Ministry of Health, especially with respect to the cost of dispensed medication. Technical information was obtained from the ordinances that regulate the Program. Expenditure from 2000 to 2007 was obtained from the Sistema Único de Saúde's (Unified Healthcare System) Outpatient Information System. All drugs dispensed between 1993 and 2009 and the amount and cost of each procedure were evaluated, based on information from the high-complexity procedure authorization of each of the country's states. The Program changed with the increase in the number of pharmacological agents and presentations distributed by, and the number of diseases contemplated in the program. In 1993, the program distributed 15 pharmacological agents in 31 distinct presentations. This number increased to 109 agents in 243 presentations in 2009. Total Ministry of Health expenditure with medications was R$1,410,181,600.74 in 2007, almost twice the amount spent in 2000, R$684,975,404.43. Diseases whose expenditure increased in the period included chronic renal insufficiency, transplantation, and hepatitis C. The Exceptional Circumstance Drug Dispensing Program is in constant transformation, aimed at building instruments and strategies that can ensure and expand access to medication among the population. Alternatives should be sought to decrease the financial impact of the Program to a level that does not impact other sectors of the health care system, given the high cost associated with novel interventions.

  17. Effects of mental demands during dispensing on perceived medication safety and employee well-being: a study of workload in pediatric hospital pharmacies.

    Science.gov (United States)

    Holden, Richard J; Patel, Neal R; Scanlon, Matthew C; Shalaby, Theresa M; Arnold, Judi M; Karsh, Ben-Tzion

    2010-12-01

    Pharmacy workload is a modifiable work system factor believed to affect both medication safety outcomes and employee outcomes, such as job satisfaction. This study sought to measure the effect of workload on safety and employee outcomes in 2 pediatric hospitals and to do so using a novel approach to pharmacy workload measurement. Rather than measuring prescription volume or other similar indicators, this study measured the type and intensity of mental demands experienced during the medication dispensing tasks. The effects of external (interruptions, divided attention, and rushing) and internal (concentration and effort) task demands on perceived medication error likelihood, adverse drug event likelihood, job dissatisfaction, and burnout were statistically estimated using multiple linear and logistic regression. Pharmacists and pharmacy technicians reported high levels of external and internal mental demands during dispensing. The study supported the hypothesis that external demands (interruptions, divided attention, and rushing) negatively impacted medication safety and employee well-being outcomes. However, as hypothesized, increasing levels of internal demands (concentration and effort) were not associated with greater perceived likelihood of error, adverse drug events, or burnout and even had a positive effect on job satisfaction. Replicating a prior study in nursing, this study shows that new conceptualizations and measures of workload can generate important new findings about both detrimental and beneficial effects of workload on patient safety and employee well-being. This study discusses what those findings imply for policy, management, and design concerning automation, cognition, and staffing. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Effects of mental demands during dispensing on perceived medication safety and employee well being: A study of workload in pediatric hospital pharmacies

    Science.gov (United States)

    Holden, Richard J.; Patel, Neal R.; Scanlon, Matthew C.; Shalaby, Theresa M.; Arnold, Judi M.; Karsh, Ben-Tzion

    2009-01-01

    Background Pharmacy workload is a modifiable work system factor believed to affect both medication safety outcomes and employee outcomes such as job satisfaction. Objectives This study sought to measure the effect of workload on safety and employee outcomes in two pediatric hospitals and to do so using a novel approach to pharmacy workload measurement. Methods Rather than measuring prescription volume or other similar indicators, this study measured the type and intensity of mental demands experienced during the medication dispensing tasks. The effects of external (interruptions, divided attention, rushing) and internal (concentration, effort) task demands on perceived medication error likelihood, adverse drug event likelihood, job dissatisfaction, and burnout were statistically estimated using multiple linear and logistic regression. Results Pharmacists and pharmacy technicians reported high levels of external and internal mental demands during dispensing. The study supported the hypothesis that external demands (interruptions, divided attention, rushing) negatively impacted medication safety and employee well being outcomes. However, as hypothesized, increasing levels of internal demands (concentration and effort) were not associated with greater perceived likelihood of error, adverse drug events, or burnout, and even had a positive effect on job satisfaction. Conclusion Replicating a prior study in nursing, this study shows that new conceptualizations and measures of workload can generate important new findings about both detrimental and beneficial effects of workload on patient safety and employee well being. This study discusses what those findings imply for policy, management, and design concerning automation, cognition, and staffing. PMID:21111387

  19. Comparison of traditional low-dose-rate to optimized and nonoptimized high-dose-rate tandem and ovoid dosimetry

    International Nuclear Information System (INIS)

    Decker, William E.; Erickson, Beth; Albano, Katherine; Gillin, Michael

    2001-01-01

    Purpose: Few dose specification guidelines exist when attempting to perform high-dose-rate (HDR) dosimetry. The purpose of this study was to model low-dose-rate (LDR) dosimetry, using parameters common in HDR dosimetry, to achieve the 'pear-shape' dose distribution achieved with LDR tandem and ovoid applications. Methods and Materials: Radiographs of Fletcher-Suit LDR applicators and Nucletron 'Fletcher-like' HDR applicators were taken with the applicators in an idealized geometry. Traditional Fletcher loadings of 3M Cs-137 sources and the Theratronics Planning System were used for LDR dosimetry. HDR dosimetry was performed using the Nucletron Microselectron HDR UPS V11.22 with an Ir-192 source. Dose optimization points were initially located along a line 2 cm lateral to the tandem, beginning at the tandem tip at 0.5-cm intervals, ending at the sail, and optimized to 100% of the point A dose. A single dose optimization point was also placed laterally from the center of each ovoid equal to the radius of the ovoid (ovoid surface dose). For purposes of comparison, dose was also calculated for points A and B, and a point located 1 cm superior to the tandem tip in the plane of the tandem, (point F). Four- and 6-cm tandem lengths and 2.0-, 2.5-, and 3.0-cm ovoid diameters were used for this study. Based on initial findings, dose optimization schemes were developed to best approximate LDR dosimetry. Finally, radiographs were obtained of HDR applications in two patients. These radiographs were used to compare the optimization schemes with 'nonoptimized' treatment plans. Results: Calculated doses for points A and B were similar for LDR, optimized HDR, and nonoptimized HDR. The optimization scheme that used tapered dose points at the tandem tip and optimized a single ovoid surface point on each ovoid to 170% of point A resulted in a good approximation of LDR dosimetry. Nonoptimized HDR resulted in higher doses at point F, the bladder, and at points lateral to the tandem tip

  20. DREAM: Classification scheme for dialog acts in clinical research query mediation.

    Science.gov (United States)

    Hoxha, Julia; Chandar, Praveen; He, Zhe; Cimino, James; Hanauer, David; Weng, Chunhua

    2016-02-01

    Clinical data access involves complex but opaque communication between medical researchers and query analysts. Understanding such communication is indispensable for designing intelligent human-machine dialog systems that automate query formulation. This study investigates email communication and proposes a novel scheme for classifying dialog acts in clinical research query mediation. We analyzed 315 email messages exchanged in the communication for 20 data requests obtained from three institutions. The messages were segmented into 1333 utterance units. Through a rigorous process, we developed a classification scheme and applied it for dialog act annotation of the extracted utterances. Evaluation results with high inter-annotator agreement demonstrate the reliability of this scheme. This dataset is used to contribute preliminary understanding of dialog acts distribution and conversation flow in this dialog space. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Process computers automate CERN power supply installations

    CERN Document Server

    Ullrich, H

    1974-01-01

    Computerized automation systems are being used at CERN, Geneva, to improve the capacity, operational reliability and flexibility of the power supply installations for main ring magnets in the experimental zones of particle accelerators. A detailed account of the technological problem involved is followed in the article by a description of the system configuration, the program system and field experience already gathered in similar schemes. (1 refs).

  2. A spatiotemporal-based scheme for efficient registration-based segmentation of thoracic 4-D MRI.

    Science.gov (United States)

    Yang, Y; Van Reeth, E; Poh, C L; Tan, C H; Tham, I W K

    2014-05-01

    Dynamic three-dimensional (3-D) (four-dimensional, 4-D) magnetic resonance (MR) imaging is gaining importance in the study of pulmonary motion for respiratory diseases and pulmonary tumor motion for radiotherapy. To perform quantitative analysis using 4-D MR images, segmentation of anatomical structures such as the lung and pulmonary tumor is required. Manual segmentation of entire thoracic 4-D MRI data that typically contains many 3-D volumes acquired over several breathing cycles is extremely tedious, time consuming, and suffers high user variability. This requires the development of new automated segmentation schemes for 4-D MRI data segmentation. Registration-based segmentation technique that uses automatic registration methods for segmentation has been shown to be an accurate method to segment structures for 4-D data series. However, directly applying registration-based segmentation to segment 4-D MRI series lacks efficiency. Here we propose an automated 4-D registration-based segmentation scheme that is based on spatiotemporal information for the segmentation of thoracic 4-D MR lung images. The proposed scheme saved up to 95% of computation amount while achieving comparable accurate segmentations compared to directly applying registration-based segmentation to 4-D dataset. The scheme facilitates rapid 3-D/4-D visualization of the lung and tumor motion and potentially the tracking of tumor during radiation delivery.

  3. On the security of two remote user authentication schemes for telecare medical information systems.

    Science.gov (United States)

    Kim, Kee-Won; Lee, Jae-Dong

    2014-05-01

    The telecare medical information systems (TMISs) support convenient and rapid health-care services. A secure and efficient authentication scheme for TMIS provides safeguarding patients' electronic patient records (EPRs) and helps health care workers and medical personnel to rapidly making correct clinical decisions. Recently, Kumari et al. proposed a password based user authentication scheme using smart cards for TMIS, and claimed that the proposed scheme could resist various malicious attacks. However, we point out that their scheme is still vulnerable to lost smart card and cannot provide forward secrecy. Subsequently, Das and Goswami proposed a secure and efficient uniqueness-and-anonymity-preserving remote user authentication scheme for connected health care. They simulated their scheme for the formal security verification using the widely-accepted automated validation of Internet security protocols and applications (AVISPA) tool to ensure that their scheme is secure against passive and active attacks. However, we show that their scheme is still vulnerable to smart card loss attacks and cannot provide forward secrecy property. The proposed cryptanalysis discourages any use of the two schemes under investigation in practice and reveals some subtleties and challenges in designing this type of schemes.

  4. Radiation therapy of malignant melanomas: an evaluation of clinically used fractionation schemes

    International Nuclear Information System (INIS)

    Strauss, A.; Dritschilo, A.; Nathanson, L.; Piro, A.J.

    1981-01-01

    To assess the importance of radiation dose fraction size in the treatment of malignant melanomas, the records of 48 patients (83 sites) treated at Tufts-New England Medical Center from 1971 to 1979 have been retrospectively reviewed. During this period, the dose fractionation schemes evolved from standard fraction size to large-dose techniques. Radiation fraction size was observed to be the major factor in the clinical response of melanoma. Fractions of 600-800 rad resulted in the best overall response (80%). The rapid fractionation scheme of 800-400-400 rad on successive days resulted in intermediate response (58%) and may be useful for the palliative treatment of selected patients

  5. Dispensing of vitamin products by retail pharmacies in South Africa ...

    African Journals Online (AJOL)

    Ilse Truter

    Survey) years.7 About 39% of US residents have used at least one multivitamin and ... The ATC Classification system is recommended by the. World Health ... Females in the 30 to 39-year age group were dispensed 21.95% of products ...

  6. Aspects of Chemical Composition and Somatic Cell count of Cow Milk Marketed at Dispensers

    Directory of Open Access Journals (Sweden)

    Mircea Valentin MUNTEAN

    2018-05-01

    Full Text Available Milk quality is influenced by many factors: lactation, fat, protein, lactose, number of somatic cells. In order to process raw milk and compare with criteria of quality and food safety the Regulation of European Parliament and the council no. 853/2004. Analysing the total number of somatic cells (SCC in the period July-August 2017 it is noted that in case of samples collected from first automatic milk dispenser exceed 2 times the maximum admissible values and the samples collected from second automatic milk dispenser are up to the maximum allowable values which show that milking hygiene and animal health are at the European standards required. Analysis of fat content for both cases indicates that it is within the standard values for cow's milk and fat variations for DM1 samples are very low at temperatures above 30 degrees Celsius which shows that high temperatures do not influence these parameters. The biological material study was represented analysed by 30 samples of milk from only two cow milk dispensers functional located in this period in Cluj-Napoca city. These samples were collected at the same time period during July-August months. The aim of present study is to determine whether milk marketed through dispensers under the high temperature conditions specific to this period is affected in terms of qualitative parameter analysis.

  7. A flexible-dose dispenser for immediate and extended release 3D printed tablets.

    Science.gov (United States)

    Pietrzak, Katarzyna; Isreb, Abdullah; Alhnan, Mohamed A

    2015-10-01

    The advances in personalised medicine increased the demand for a fast, accurate and reliable production method of tablets that can be digitally controlled by healthcare staff. A flexible dose tablet system is presented in this study that proved to be suitable for immediate and extended release tablets with a realistic drug loading and an easy-to-swallow tablet design. The method bridges the affordable and digitally controlled Fused Deposition Modelling (FDM) 3D printing with a standard pharmaceutical manufacturing process, Hot Melt Extrusion (HME). The reported method was compatible with three methacrylic polymers (Eudragit RL, RS and E) as well as a cellulose-based one (hydroxypropyl cellulose, HPC SSL). The use of a HME based pharmaceutical filament preserved the linear relationship between the mass and printed volume and was utilized to digitally control the dose via an input from computer software with dose accuracy in the range of 91-95%. Higher resolution printing quality doubled the printing time, but showed a little effect on in vitro release pattern of theophylline and weight accuracy. Physical characterization studies indicated that the majority of the model drug (theophylline) in the 3D printed tablet exists in a crystal form. Owing to the small size, ease of use and the highly adjustable nature of FDM 3D printers, the method holds promise for future individualised treatment. Copyright © 2015. Published by Elsevier B.V.

  8. Fully automated MR liver volumetry using watershed segmentation coupled with active contouring.

    Science.gov (United States)

    Huynh, Hieu Trung; Le-Trong, Ngoc; Bao, Pham The; Oto, Aytek; Suzuki, Kenji

    2017-02-01

    Our purpose is to develop a fully automated scheme for liver volume measurement in abdominal MR images, without requiring any user input or interaction. The proposed scheme is fully automatic for liver volumetry from 3D abdominal MR images, and it consists of three main stages: preprocessing, rough liver shape generation, and liver extraction. The preprocessing stage reduced noise and enhanced the liver boundaries in 3D abdominal MR images. The rough liver shape was revealed fully automatically by using the watershed segmentation, thresholding transform, morphological operations, and statistical properties of the liver. An active contour model was applied to refine the rough liver shape to precisely obtain the liver boundaries. The liver volumes calculated by the proposed scheme were compared to the "gold standard" references which were estimated by an expert abdominal radiologist. The liver volumes computed by using our developed scheme excellently agreed (Intra-class correlation coefficient was 0.94) with the "gold standard" manual volumes by the radiologist in the evaluation with 27 cases from multiple medical centers. The running time was 8.4 min per case on average. We developed a fully automated liver volumetry scheme in MR, which does not require any interaction by users. It was evaluated with cases from multiple medical centers. The liver volumetry performance of our developed system was comparable to that of the gold standard manual volumetry, and it saved radiologists' time for manual liver volumetry of 24.7 min per case.

  9. The association between lifting an administrative restriction on antidepressant dispensing and treatment patterns in Iceland

    DEFF Research Database (Denmark)

    Thengilsdottir, G; Gardarsdottir, H; Almarsdóttir, Anna Birna

    2013-01-01

    On March 1st 2009, restrictions on the dispensing of selective serotonin reuptake inhibitors (SSRI) in Iceland were lifted. Incident rates and changes in early discontinuation and switching before and after the change were investigated.......On March 1st 2009, restrictions on the dispensing of selective serotonin reuptake inhibitors (SSRI) in Iceland were lifted. Incident rates and changes in early discontinuation and switching before and after the change were investigated....

  10. Individualized Dose Prescription for Hypofractionation in Advanced Non-Small-Cell Lung Cancer Radiotherapy: An in silico Trial

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Aswin L.; Troost, Esther G.C.; Huizenga, Henk; Kaanders, Johannes H.A.M. [Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands); Bussink, Johan, E-mail: j.bussink@rther.umcn.nl [Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands)

    2012-08-01

    Purpose: Local tumor control and outcome remain poor in patients with advanced non-small-cell lung cancer (NSCLC) treated by external beam radiotherapy. We investigated the therapeutic gain of individualized dose prescription with dose escalation based on normal tissue dose constraints for various hypofractionation schemes delivered with intensity-modulated radiation therapy. Methods and Materials: For 38 Stage III NSCLC patients, the dose level of an existing curative treatment plan with standard fractionation (66 Gy) was rescaled based on dose constraints for the lung, spinal cord, esophagus, brachial plexus, and heart. The effect on tumor total dose (TTD) and biologic tumor effective dose in 2-Gy fractions (TED) corrected for overall treatment time (OTT) was compared for isotoxic and maximally tolerable schemes given in 15, 20, and 33 fractions. Rescaling was accomplished by altering the dose per fraction and/or the number of fractions while keeping the relative dose distribution of the original treatment plan. Results: For 30 of the 38 patients, dose escalation by individualized hypofractionation yielded therapeutic gain. For the maximally tolerable dose scheme in 33 fractions (MTD{sub 33}), individualized dose escalation resulted in a 2.5-21% gain in TTD. In the isotoxic schemes, the number of fractions could be reduced with a marginal increase in TED. For the maximally tolerable dose schemes, the TED could be escalated up to 36.6%, and for all patients beyond the level of the isotoxic and the MTD{sub 33} schemes (range, 3.3-36.6%). Reduction of the OTT contributed to the therapeutic gain of the shortened schemes. For the maximally tolerable schemes, the maximum esophageal dose was the dominant dose-limiting constraint in most patients. Conclusions: This modeling study showed that individualized dose prescription for hypofractionation in NSCLC radiotherapy, based on scaling of existing treatment plans up to normal tissue dose constraints, enables dose

  11. Fabrication and Measurement of Low Work Function Cesiated Dispenser Photocathodes

    CERN Document Server

    Moody, Nathan A; Jensen, Kevin

    2005-01-01

    Photoinjector performance is a limiting factor in the continued development of high powered FELs and electron beam-based accelerators. Presently available photocathodes are plagued with limited efficiency and short lifetime in an RF-gun environment, due to contamination or evaporation of a photosensitive surface layer. An ideal photocathode should have high efficiency at long wavelengths, long lifetime in practical vacuum environments, and prompt emission. Cathodes with high efficiency typically have limited lifetime, and vice versa, and the needs of the photocathode are generally at odds with those of the drive laser. A potential solution is the low work function dispenser cathode, where lifetime issues are overcome by periodic in situ regeneration that restores the photosensitive surface layer, analogous to those used in the microwave power tube industry. This work reports on the fabrication techniques and performance of cesiated metal photocathodes and cesiated dispenser cathodes, with a focus on understan...

  12. IoT based retail automation of fuel station and alert system

    Science.gov (United States)

    Naveen kumar, P.; Kumaresan, P.; Babu Sundaresan, Y.

    2017-11-01

    In this new era everyday life is filled with technology from the start up till to bed. In olden days people mostly worked within circle or walkable distance but now the technology developing day by day to reduce the work as well as time taken by work to complete.Thestuff’s in our daily process, somehow we left some lot of work due to lack of time. In today’s life most probably utmost 50% of products all came with automation and making theconsumers/users to access those products from anywhere by using their mobile or gadgets. In this paper, it deals with automation of fuel station retail outlet; this system will give the sales and stock report to the owner for every hour. The main problem is customer complaints about less quantityof fuel is issued or filled for money given and customers get diverted theirs attention by operators and refill the fuel without they resetting the nozzle. Nowadays to overcome these problems they replaced some electronic and computerised fuel dispensers but there is no way to identify inside the rotary valve adjustments by fitter.

  13. Automated assessment of aortic and main pulmonary arterial diameters using model-based blood vessel segmentation for predicting chronic thromboembolic pulmonary hypertension in low-dose CT lung screening

    Science.gov (United States)

    Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Sugiura, Toshihiko; Tanabe, Nobuhiro; Kusumoto, Masahiko; Eguchi, Kenji; Kaneko, Masahiro

    2018-02-01

    Chronic thromboembolic pulmonary hypertension (CTEPH) is characterized by obstruction of the pulmonary vasculature by residual organized thrombi. A morphological abnormality inside mediastinum of CTEPH patient is enlargement of pulmonary artery. This paper presents an automated assessment of aortic and main pulmonary arterial diameters for predicting CTEPH in low-dose CT lung screening. The distinctive feature of our method is to segment aorta and main pulmonary artery using both of prior probability and vascular direction which were estimated from mediastinal vascular region using principal curvatures of four-dimensional hyper surface. The method was applied to two datasets, 64 lowdose CT scans of lung cancer screening and 19 normal-dose CT scans of CTEPH patients through the training phase with 121 low-dose CT scans. This paper demonstrates effectiveness of our method for predicting CTEPH in low-dose CT screening.

  14. Dispensing of drugs with and without a prescription from private ...

    African Journals Online (AJOL)

    There is little literature available on dispensing patterns and unsupervised sale of medicines from pharmacies in Tanzania. The present study assessed the patterns of drug acquisition from pharmacies by customers: whether by prescription, recommended by pharmacist, or requested by a customer without a prescription.

  15. Radiation therapy of malignant melanomas: an evaluation of clinically used fractionation schemes

    International Nuclear Information System (INIS)

    Strauss, A.; Dritschilo, A.; Nathanson, L.; Piro, A.J.

    1981-01-01

    To assess the importance of radiation dose fraction size in the treatment of malignant melanomas, the records of 48 patients (83 sites) treated at Tufts-New England Medical Center from 1971 to 1979 have been retrospectively reviewed. During this period, the dose fractionation schemes evolved from standard fraction size to large-dose techniques. Radiation fraction size was observed to be the major factor in the clinical response of melanoma. Fractions of 600 to 800 rad resulted in the best overall response (80%). The rapid fractionation scheme of 800 to 400 to 400 rad on successive days resulted in intermediate response (58%) and may be useful for the palliative treatment of selected patients

  16. The impact of ethnic density on dispensing of antipsychotic and antidepressant medication among immigrants in the Netherlands.

    Science.gov (United States)

    Termorshuizen, Fabian; Heerdink, Eibert R; Selten, Jean-Paul

    2018-06-12

    A higher own-group ethnic density in the area of residence is often associated with a lower risk for psychotic disorder. For common mental disorders the evidence is less convincing. This study explores whether these findings are mirrored in data on dispensing of antipsychotics and antidepressants. Health insurance data on dispensed medication among all adults living in the four largest Dutch cities were linked to demographic data from Statistics Netherlands. Dispensing of antipsychotics and antidepressants in 2013 was analyzed in relation to the proportion of the own ethnic group in the neighborhood. Higher own-group ethnic density was associated with lower dispensing of antipsychotics among the Moroccan-Dutch (N = 115,455), after adjusting for age, gender, and SES of the neighborhood (OR adj for the highest vs. the lowest density quintile = 0.72 [0.66-0.79]). However, this association vanished after adjustment for household composition (OR adj  = 0.93 [0.85-1.03]). Similar results were found for the Turkish-Dutch (N = 105,460) (OR adj  = 0.86 [0.76-0.96] and 1.05 [0.94-1.18]). For those of Surinamese (N = 147,123) and Antillean origin (N = 41,430), in contrast, the association between ethnic density and lower risk remained after each adjustment (P density was consistently found for those of Antillean origin (OR adj  = 0.62 [0.52-0.74]) only. These data on dispensing of psychomedication confirm the ethnic density hypothesis for psychosis alongside earlier equivocal findings for other mental disorders. The negative association between own-group ethnic density and dispensing of antipsychotics among the Moroccan- and Turkish-Dutch may be explained, at least in part, by a favourable household composition (i.e., living in a family) in high-density neighborhoods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Interstitial high-dose-rate brachytherapy boost: The feasibility and cosmetic outcome of a fractionated outpatient delivery scheme

    International Nuclear Information System (INIS)

    Manning, Matthew A.; Arthur, Douglas W.; Schmidt-Ullrich, Rupert K.; Arnfield, Mark R.; Amir, Cyrus; Zwicker, Robert D.

    2000-01-01

    Purpose: To evaluate the feasibility, potential toxicity, and cosmetic outcome of fractionated interstitial high dose rate (HDR) brachytherapy boost for the management of patients with breast cancer at increased risk for local recurrence. Methods and Materials: From 1994 to 1996, 18 women with early stage breast cancer underwent conventionally fractionated whole breast radiotherapy (50-50.4 Gy) followed by interstitial HDR brachytherapy boost. All were considered to be at high risk for local failure. Seventeen had pathologically confirmed final surgical margins of less than 2 mm or focally positive. Brachytherapy catheter placement and treatment delivery were conducted on an outpatient basis. Preplanning was used to determine optimal catheter positions to enhance dose homogeneity of dose delivery. The total HDR boost dose was 15 Gy delivered in 6 fractions of 2.5 Gy over 3 days. Local control, survival, late toxicities (LENT-SOMA), and cosmetic outcome were recorded in follow-up. In addition, factors potentially influencing cosmesis were analyzed by logistic regression analysis. Results: The minimum follow-up is 40 months with a median 50 months. Sixteen patients were alive without disease at last follow-up. There have been no in-breast failures observed. One patient died with brain metastases, and another died of unrelated causes without evidence of disease. Grade 1-2 late toxicities included 39% with hyperpigmentation, 56% with detectable fibrosis, 28% with occasional discomfort, and 11% with visible telangiectasias. Grade 3 toxicity was reported in one patient as persistent discomfort. Sixty-seven percent of patients were considered to have experienced good/excellent cosmetic outcomes. Factors with a direct relationship to adverse cosmetic outcome were extent of surgical defect (p = 0.00001), primary excision volume (p = 0.017), and total excision volume (p = 0.015). Conclusions: For high risk patients who may benefit from increased doses, interstitial HDR

  18. Automated Endmember Selection for Nonlinear Unmixing of Lunar Spectra

    Science.gov (United States)

    Felder, M. P.; Grumpe, A.; Wöhler, C.; Mall, U.

    2013-09-01

    An important aspect of the analysis of remotely sensed lunar reflectance spectra is their decomposition into intimately mixed constituents. While some methods rely on unmixing of the observed reflectance spectra [1] or on the identification of minerals by extracting the depths and positions of mineral-specific absorption troughs [2, 3], these approaches do not allow for an automated selection of the (a priori unknown) endmembers from a large set of possible constituents. In this study, a non-linear spectral unmixing approach combined with an automated endmember selection scheme is proposed. This method is applied to reflectance spectra of the SIR-2 point spectrometer [4] carried by the Chandrayaan-1 spacecraft.

  19. Identification of risks associated with the prescribing and dispensing of oral anticancer medicines in Ireland.

    LENUS (Irish Health Repository)

    Hammond, Lisa

    2012-09-09

    Background Oral anticancer medicines (OAM) facilitate transfer of cancer care into the community, where safeguards developed in hospitals that control their prescribing, dispensing and administration may not exist. Objective To determine if the systems of prescribing and dispensing OAM in Ireland facilitate clinical verification of the prescription, thereby ensuring treatment is tailored and appropriate for the patient. Setting Randomly selected community pharmacies in Ireland and all Irish hospitals with cancer services. Method A questionnaire was sent to a random selection of Irish community pharmacists. A different questionnaire was sent to all Irish hospitals treating cancer patients. One hundred OAM prescriptions were retrospectively reviewed, to assess the information presented and the potential barriers to a community pharmacist performing a clinical verification of the prescription. Main outcome measure Community pharmacist survey: problems experienced when dispensing OAM and risk factors identified with the current system. Hospital pharmacist survey: proportion of hospitals that clinically verify prescriptions for parenteral versus oral anticancer medicines and associated policies. OAM prescription review: proportion of OAM prescriptions that contained sufficient information for a community pharmacist to clinically verify the prescription and safely dispense the medication. Results Sixty-four percent of community pharmacist respondents felt they did not have enough information available to them to safely dispense these prescriptions, and 74 % felt that patients are at risk with the current Irish system of prescribing and dispensing OAM. Irish hospitals do not have systems to ensure that all OAM prescriptions are clinically verified by a pharmacist. Seventeen different agents were prescribed on the prescriptions reviewed. The information provided to the community pharmacist would have allowed them to clinically verify 7 % of the OAM prescriptions

  20. "This is not a drill": Activation of a student-led influenza vaccination point of dispensing.

    Science.gov (United States)

    Adams, Lavonne M; Canclini, Sharon; Tillman, Kelle

    2018-04-13

    To describe activation of a Point of dispensing (POD) in response to an influenza outbreak, highlighting the use of a student-led model. Faculty, staff, and students of Harris College of Nursing and Health Sciences, Texas Christian University (TCU), as well as those located in its primary building. In response to an August 2017 influenza outbreak, a vaccination clinic was conducted for a target population through POD activation. The larger campus community was served through provision of additional doses by the Texas Christian University Health Center and the annual October student-led vaccination clinic. Eleven additional cases were diagnosed after vaccinations began. One hundred percent of the targeted population was vaccinated (n = 824), with an additional 127 participants vaccinated (others working in the building where POD held also vaccinated). This was the first time POD activation had occurred on campus in response to an outbreak.

  1. Fetal doses to pregnant patients from CT with tube current modulation calculated using Monte Carlo simulations and realistic phantoms

    International Nuclear Information System (INIS)

    Gu, J.; George Xu, X.; Caracappa, P. F.; Liu, B.

    2013-01-01

    To investigate the radiation dose to the fetus using retrospective tube current modulation (TCM) data selected from archived clinical records. This paper describes the calculation of fetal doses using retrospective TCM data and Monte Carlo (MC) simulations. Three TCM schemes were adopted for use with three pregnant patient phantoms. MC simulations were used to model CT scanners, TCM schemes and pregnant patients. Comparisons between organ doses from TCM schemes and those from non-TCM schemes show that these three TCM schemes reduced fetal doses by 14, 18 and 25 %, respectively. These organ doses were also compared with those from ImPACT calculation. It is found that the difference between the calculated fetal dose and the ImPACT reported dose is as high as 46 %. This work demonstrates methods to study organ doses from various TCM protocols and potential ways to improve the accuracy of CT dose calculation for pregnant patients. (authors)

  2. 40 CFR Table 1 to Subpart Cccccc... - Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly...

    Science.gov (United States)

    2010-07-01

    ... Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More...

  3. Monitored Retrievable Storage/Multi-Purpose Canister analysis: Simulation and economics of automation

    International Nuclear Information System (INIS)

    Bennett, P.C.; Stringer, J.B.

    1994-01-01

    Robotic automation is examined as a possible alternative to manual spent nuclear fuel, transport cask and Multi-Purpose canister (MPC) handling at a Monitored Retrievable Storage (MRS) facility. Automation of key operational aspects for the MRS/MPC system are analyzed to determine equipment requirements, through-put times and equipment costs is described. The economic and radiation dose impacts resulting from this automation are compared to manual handling methods

  4. SU-E-I-89: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Pediatric Anthropomorphic and ACR Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Mahmood, U; Erdi, Y; Wang, W [Memorial Sloan Kettering Cancer Center, NY, NY (United States)

    2014-06-01

    Purpose: To assess the impact of General Electrics automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of a pediatric anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, 80 mA, 0.7s rotation time. Image quality was assessed by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: For the baseline protocol, CNR was found to decrease from 0.460 ± 0.182 to 0.420 ± 0.057 when kVa was activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.620 ± 0.040. The liver dose decreased by 30% with kVa activation. Conclusion: Application of kVa reduces the liver dose up to 30%. However, reduction in image quality for abdominal scans occurs when using the automated tube voltage selection feature at the baseline protocol. As demonstrated by the CNR and NPS analysis, the texture and magnitude of the noise in reconstructed images at ASiR 40% was found to be the same as our baseline images. We have demonstrated that 30% dose reduction is possible when using 40% ASiR with kVa in pediatric patients.

  5. SU-E-I-89: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Pediatric Anthropomorphic and ACR Phantoms

    International Nuclear Information System (INIS)

    Mahmood, U; Erdi, Y; Wang, W

    2014-01-01

    Purpose: To assess the impact of General Electrics automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of a pediatric anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, 80 mA, 0.7s rotation time. Image quality was assessed by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: For the baseline protocol, CNR was found to decrease from 0.460 ± 0.182 to 0.420 ± 0.057 when kVa was activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.620 ± 0.040. The liver dose decreased by 30% with kVa activation. Conclusion: Application of kVa reduces the liver dose up to 30%. However, reduction in image quality for abdominal scans occurs when using the automated tube voltage selection feature at the baseline protocol. As demonstrated by the CNR and NPS analysis, the texture and magnitude of the noise in reconstructed images at ASiR 40% was found to be the same as our baseline images. We have demonstrated that 30% dose reduction is possible when using 40% ASiR with kVa in pediatric patients

  6. A robust anonymous biometric-based remote user authentication scheme using smart cards

    Directory of Open Access Journals (Sweden)

    Ashok Kumar Das

    2015-04-01

    Full Text Available Several biometric-based remote user authentication schemes using smart cards have been proposed in the literature in order to improve the security weaknesses in user authentication system. In 2012, An proposed an enhanced biometric-based remote user authentication scheme using smart cards. It was claimed that the proposed scheme is secure against the user impersonation attack, the server masquerading attack, the password guessing attack, and the insider attack and provides mutual authentication between the user and the server. In this paper, we first analyze the security of An’s scheme and we show that this scheme has three serious security flaws in the design of the scheme: (i flaw in user’s biometric verification during the login phase, (ii flaw in user’s password verification during the login and authentication phases, and (iii flaw in user’s password change locally at any time by the user. Due to these security flaws, An’s scheme cannot support mutual authentication between the user and the server. Further, we show that An’s scheme cannot prevent insider attack. In order to remedy the security weaknesses found in An’s scheme, we propose a new robust and secure anonymous biometric-based remote user authentication scheme using smart cards. Through the informal and formal security analysis, we show that our scheme is secure against all possible known attacks including the attacks found in An’s scheme. The simulation results of our scheme using the widely-accepted AVISPA (Automated Validation of Internet Security Protocols and Applications tool ensure that our scheme is secure against passive and active attacks. In addition, our scheme is also comparable in terms of the communication and computational overheads with An’s scheme and other related existing schemes. As a result, our scheme is more appropriate for practical applications compared to other approaches.

  7. PLACE: an open-source python package for laboratory automation, control, and experimentation.

    Science.gov (United States)

    Johnson, Jami L; Tom Wörden, Henrik; van Wijk, Kasper

    2015-02-01

    In modern laboratories, software can drive the full experimental process from data acquisition to storage, processing, and analysis. The automation of laboratory data acquisition is an important consideration for every laboratory. When implementing a laboratory automation scheme, important parameters include its reliability, time to implement, adaptability, and compatibility with software used at other stages of experimentation. In this article, we present an open-source, flexible, and extensible Python package for Laboratory Automation, Control, and Experimentation (PLACE). The package uses modular organization and clear design principles; therefore, it can be easily customized or expanded to meet the needs of diverse laboratories. We discuss the organization of PLACE, data-handling considerations, and then present an example using PLACE for laser-ultrasound experiments. Finally, we demonstrate the seamless transition to post-processing and analysis with Python through the development of an analysis module for data produced by PLACE automation. © 2014 Society for Laboratory Automation and Screening.

  8. How automated image analysis techniques help scientists in species identification and classification?

    Science.gov (United States)

    Yousef Kalafi, Elham; Town, Christopher; Kaur Dhillon, Sarinder

    2017-09-04

    Identification of taxonomy at a specific level is time consuming and reliant upon expert ecologists. Hence the demand for automated species identification increased over the last two decades. Automation of data classification is primarily focussed on images, incorporating and analysing image data has recently become easier due to developments in computational technology. Research efforts in identification of species include specimens' image processing, extraction of identical features, followed by classifying them into correct categories. In this paper, we discuss recent automated species identification systems, categorizing and evaluating their methods. We reviewed and compared different methods in step by step scheme of automated identification and classification systems of species images. The selection of methods is influenced by many variables such as level of classification, number of training data and complexity of images. The aim of writing this paper is to provide researchers and scientists an extensive background study on work related to automated species identification, focusing on pattern recognition techniques in building such systems for biodiversity studies.

  9. Automation of TL brick dating by ADAM-1

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Hirsl, P.; Jirousek, P.; Kubelik, M.; Musilek, L.; Kanaval, J.

    2000-01-01

    supralinearity of the response at low doses, the first group of nine samples is irradiated by doses of beta radiation after the measurement of the value 'N'. All procedures of alpha and beta irradiation by varying doses and the TL- signal measurement as also the age evaluation and error assessment are programmable and fully automated. (author)

  10. Understanding the Role of Accredited Drug Dispensing Outlets in Tanzania's Health System.

    Directory of Open Access Journals (Sweden)

    Martha Embrey

    Full Text Available People in many low-income countries access medicines from retail drug shops. In Tanzania, a public-private partnership launched in 2003 used an accreditation approach to improve access to quality medicines and pharmaceutical services in underserved areas. The government scaled up the accredited drug dispensing outlet (ADDO program nationally, with over 9,000 shops now accredited. This study assessed the relationships between community members and their sources of health care and medicines, particularly antimicrobials, with a specific focus on the role ADDOs play in the health care system.Using mixed methods, we collected data in four regions. We surveyed 1,185 households and audited 96 ADDOs and 84 public/nongovernmental health facilities using a list of 17 tracer drugs. To determine practices in health facilities, we interviewed 1,365 exiting patients. To assess dispensing practices, mystery shoppers visited 306 ADDOs presenting one of three scenarios (102 each about a child's respiratory symptoms.Of 614 household members with a recent acute illness, 73% sought outside care-30% at a public facility and 31% at an ADDO. However, people bought medicines more often at ADDOs no matter who recommended the treatment; of the 581 medicines that people had received, 49% came from an ADDO. Although health facilities and ADDOs had similar availability of antimicrobials, ADDOs had more pediatric formulations available (p<0.001. The common perception was that drugs from ADDOs are more expensive, but the difference in the median cost to treat pneumonia was relatively minimal (US$0.26 in a public facility and US$0.30 in an ADDO. Over 20% of households said they had someone with a chronic condition, with 93% taking medication, but ADDOs are allowed to sell very few chronic care-related medicines. ADDO dispensers are trained to refer complicated cases to a health facility, and notably, 99% of mystery shoppers presenting a pneumonia scenario received an

  11. Dispensing of vitamin products by retail pharmacies in South Africa ...

    African Journals Online (AJOL)

    Objective: The objective of this study was to analyse the dispensing patterns of vitamins (Anatomical Therapeutic Chemical (ATC) group A11) over a one-year period in a group of community pharmacies in South Africa. Design and setting: A retrospective drug utilisation study was conducted on community pharmacy ...

  12. Cambridge community Optometry Glaucoma Scheme.

    Science.gov (United States)

    Keenan, Jonathan; Shahid, Humma; Bourne, Rupert R; White, Andrew J; Martin, Keith R

    2015-04-01

    With a higher life expectancy, there is an increased demand for hospital glaucoma services in the United Kingdom. The Cambridge community Optometry Glaucoma Scheme (COGS) was initiated in 2010, where new referrals for suspected glaucoma are evaluated by community optometrists with a special interest in glaucoma, with virtual electronic review and validation by a consultant ophthalmologist with special interest in glaucoma. 1733 patients were evaluated by this scheme between 2010 and 2013. Clinical assessment is performed by the optometrist at a remote site. Goldmann applanation tonometry, pachymetry, monoscopic colour optic disc photographs and automated Humphrey visual field testing are performed. A clinical decision is made as to whether a patient has glaucoma or is a suspect, and referred on or discharged as a false positive referral. The clinical findings, optic disc photographs and visual field test results are transmitted electronically for virtual review by a consultant ophthalmologist. The number of false positive referrals from initial referral into the scheme. Of the patients, 46.6% were discharged at assessment and a further 5.7% were discharged following virtual review. Of the patients initially discharged, 2.8% were recalled following virtual review. Following assessment at the hospital, a further 10.5% were discharged after a single visit. The COGS community-based glaucoma screening programme is a safe and effective way of evaluating glaucoma referrals in the community and reducing false-positive referrals for glaucoma into the hospital system. © 2014 Royal Australian and New Zealand College of Ophthalmologists.

  13. Automated image quality assessment for chest CT scans.

    Science.gov (United States)

    Reeves, Anthony P; Xie, Yiting; Liu, Shuang

    2018-02-01

    Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.

  14. Integration of dispenser-printed ultra-low-voltage thermoelectric and energy storage devices

    International Nuclear Information System (INIS)

    Wang, Z; Chen, A; Winslow, R; Madan, D; Nill, M; Wright, P K; Juang, R C; Evans, J W

    2012-01-01

    This paper reports on an integrated energy harvesting prototype that consists of dispenser-printed thermoelectric energy harvesting and electrochemical energy storage devices. Parallel-connected thermoelectric devices with low internal resistances were designed, fabricated and characterized. The use of a commercially available dc-to-dc converter was explored to step-up a 27.1 mV input voltage from a printed thermoelectric device to a regulated 2.34 V output at a maximum of 34% conversion efficiency. The regulated power succeeds in charging dispenser-printed, zinc-based micro-batteries with charging efficiencies of up to 67%. The prototype presented in this work demonstrates the feasibility of deploying a printable, cost-effective and perpetual power solution for practical wireless sensor network applications. (paper)

  15. ELECTROSPUN MESOFIBERS, A NOVEL BIODEGRADABLE PHEROMONE DISPENSER TECHNOLOGY, ARE COMBINED WITH MECHANICAL DEPLOYMENT FOR EFFICIENT IPM OF LOBESIA BOTRANA IN VINEYARDS.

    Science.gov (United States)

    Hummel, Hans E; Langner, S S; Breuer, M

    2015-01-01

    Behaviour modifying pheromones are well known agents for disrupting mating communication of pest insects. For optimal activity, they must be dispensed in time and space at a quantitatively measurable, predetermined release rate covering the flight period of the target species. Pheromones appeal to environmentally conscientious entomologists for their biodegradability, non-toxicity and ecological compatibility. In attempts of combining the virtues of pheromones, suitable slow release dispensers, and their mechanical deployment, an ecologically sensible, reasonably priced and patented procedure was developed and tested with the vineyard pest Lobesia botrana (Lep.: Tortricidae). It is characterized by (1) Electrospun mesofibers with diameters ranging from 0.6 to 3.5 micrometres, containing disruptants and dispensing it by slow release diffusion into the crop, (2) simultaneous application of the fully biodegradable combination of pheromone with Ecoflex polyester mesofiber, (3) combination of mechanical deployment by multi-purpose cultivators of the prefabricated pheromone dispensers with other simultaneous cultivation measures, and thus further reducing labour time and treatment costs. The dispensers are biodegradable within half a year without leaving any objectionable residues. In the standard eco-toxicology tests pheromone dispensers are harmless to non-target organisms. The disruptive effect of one treatment lasts for seven weeks which covers well one of several flight periods of L. botrana.

  16. Impact of Robotic Dispensing Machines in German Pharmacies on ...

    African Journals Online (AJOL)

    As a result of using a robotic dispensing machine, personnel costs were reduced by an average of 4.6% during the first 12 months after start-up. Over-the-counter sales increased in the same period by an average of 6.8%. Despite average initial costs of 118,000 euros, total costs within the first 12 months fell in 50% of cases ...

  17. Radiological safety and GMP in the bulk batch manufacturing, formulation and dispensing of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Thulasidhasan, A.; Tiwary, Bikash; Kumar, Uma Sheri; Kale, Pooja; Tiwary, Richa; Gaurav, Ananad; Shah, B.K.; Topale, P.D.; Prabhakar, G.; Sachdev, S.S.

    2010-01-01

    Full text: Radiopharmaceutical Program of BRIT is involved in the manufacturing of ready to use radiopharmaceuticals for therapy for the last three decades. Ready to use Radiopharmaceutical products include, 131 I-Sodium iodide solution and capsules for thyroid carcinoma and metastatic lesions, 131 I MIBG injection for diagnosis and therapy of adrenal medullae tumors and their mets, 153 Sm-EDTMP injection and 32 P- Sodium orthophosphate injection for bone pain palliative treatment. BRIT's radiopharmaceutical production facility is a radioisotope laboratory classified as Type-III facility for handling radioisotopes of Group-II, Group-III and Group-IV approved by AERB. This facility meets all the radiological safety requirements as per AERB guidelines. Production of above mentioned radiopharmaceuticals is carried out in Production Plants (PP), β, γ Glove boxes (GB) and Fume hoods (FH). Typical production procedure involves bulk processing, formulation, sterilization and dispensing of doses. Production Plants (PP) are exclusively designed facilities to carry out the production in a radiologically safe manner, at the same time maintaining aseptic conditions required for injectables as per the current GMP. Each production plant has a leak tight Isolator box, made up of high quality SS which has provisions for remote handling devices like, Tongs, dispensing systems, service points for vacuum, gas, compressed air, water and electric power. This Isolator box is shielded from all sides by required amount of lead (2 inch or 4 inch), and has an access port called 'Transport Port Box' with double door transport lock and is equipped with a trolley. Two filter unit systems are fitted at the top of the plant and each unit comprises of activated Charcoal filter and HEPA filter in tandem, this in turn is connected to special exhaust meant for radioactive gases. Similarly, the designs of β, γ Glove boxes (GB) and Fume hoods (FH) also incorporate all radiological safety features

  18. A novel and efficient user access control scheme for wireless body area sensor networks

    Directory of Open Access Journals (Sweden)

    Santanu Chatterjee

    2014-07-01

    Full Text Available Wireless body area networks (WBANs can be applied to provide healthcare and patient monitoring. However, patient privacy can be vulnerable in a WBAN unless security is considered. Access to authorized users for the correct information and resources for different services can be provided with the help of efficient user access control mechanisms. This paper proposes a new user access control scheme for a WBAN. The proposed scheme makes use of a group-based user access ID, an access privilege mask, and a password. An elliptic curve cryptography-based public key cryptosystem is used to ensure that a particular legitimate user can only access the information for which he/she is authorized. We show that our scheme performs better than previously existing user access control schemes. Through a security analysis, we show that our scheme is secure against possible known attacks. Furthermore, through a formal security verification using the AVISPA (Automated Validation of Internet Security Protocols and Applications tool, we show that our scheme is also secure against passive and active attacks.

  19. Automated Design of Propellant-Optimal, End-to-End, Low-Thrust Trajectories for Trojan Asteroid Tours

    Science.gov (United States)

    Stuart, Jeffrey; Howell, Kathleen; Wilson, Roby

    2013-01-01

    The Sun-Jupiter Trojan asteroids are celestial bodies of great scientific interest as well as potential resources offering water and other mineral resources for longterm human exploration of the solar system. Previous investigations under this project have addressed the automated design of tours within the asteroid swarm. This investigation expands the current automation scheme by incorporating options for a complete trajectory design approach to the Trojan asteroids. Computational aspects of the design procedure are automated such that end-to-end trajectories are generated with a minimum of human interaction after key elements and constraints associated with a proposed mission concept are specified.

  20. An adjoint-based scheme for eigenvalue error improvement

    International Nuclear Information System (INIS)

    Merton, S.R.; Smedley-Stevenson, R.P.; Pain, C.C.; El-Sheikh, A.H.; Buchan, A.G.

    2011-01-01

    A scheme for improving the accuracy and reducing the error in eigenvalue calculations is presented. Using a rst order Taylor series expansion of both the eigenvalue solution and the residual of the governing equation, an approximation to the error in the eigenvalue is derived. This is done using a convolution of the equation residual and adjoint solution, which is calculated in-line with the primal solution. A defect correction on the solution is then performed in which the approximation to the error is used to apply a correction to the eigenvalue. The method is shown to dramatically improve convergence of the eigenvalue. The equation for the eigenvalue is shown to simplify when certain normalizations are applied to the eigenvector. Two such normalizations are considered; the rst of these is a fission-source type of normalisation and the second is an eigenvector normalisation. Results are demonstrated on a number of demanding elliptic problems using continuous Galerkin weighted nite elements. Moreover, the correction scheme may also be applied to hyperbolic problems and arbitrary discretization. This is not limited to spatial corrections and may be used throughout the phase space of the discrete equation. The applied correction not only improves fidelity of the calculation, it allows assessment of the reliability of numerical schemes to be made and could be used to guide mesh adaption algorithms or to automate mesh generation schemes. (author)

  1. ORIGAMI Automator Primer. Automated ORIGEN Source Terms and Spent Fuel Storage Pool Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wieselquist, William A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Thompson, Adam B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bowman, Stephen M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Peterson, Joshua L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-04-01

    Source terms and spent nuclear fuel (SNF) storage pool decay heat load analyses for operating nuclear power plants require a large number of Oak Ridge Isotope Generation and Depletion (ORIGEN) calculations. SNF source term calculations also require a significant amount of bookkeeping to track quantities such as core and assembly operating histories, spent fuel pool (SFP) residence times, heavy metal masses, and enrichments. The ORIGEN Assembly Isotopics (ORIGAMI) module in the SCALE code system provides a simple scheme for entering these data. However, given the large scope of the analysis, extensive scripting is necessary to convert formats and process data to create thousands of ORIGAMI input files (one per assembly) and to process the results into formats readily usable by follow-on analysis tools. This primer describes a project within the SCALE Fulcrum graphical user interface (GUI) called ORIGAMI Automator that was developed to automate the scripting and bookkeeping in large-scale source term analyses. The ORIGAMI Automator enables the analyst to (1) easily create, view, and edit the reactor site and assembly information, (2) automatically create and run ORIGAMI inputs, and (3) analyze the results from ORIGAMI. ORIGAMI Automator uses the standard ORIGEN binary concentrations files produced by ORIGAMI, with concentrations available at all time points in each assembly’s life. The GUI plots results such as mass, concentration, activity, and decay heat using a powerful new ORIGEN Post-Processing Utility for SCALE (OPUS) GUI component. This document includes a description and user guide for the GUI, a step-by-step tutorial for a simplified scenario, and appendices that document the file structures used.

  2. [Dispensing care at the dispensing counter in the conditions of a Czech pharmacy].

    Science.gov (United States)

    Macesková, B; Plevacová, H

    2005-03-01

    Evaluation of 108 cases when the pharmacist found a need to intervene into prescription verified the use of internationally employed system of classification of pharmaceutical interventions in the conditions of the Czech pharmacy of the basic type. The so-called dispensing care at the counter was provided by five participating pharmacists (out of seven working in the pharmacy) for a period of six months. The most frequently identified problems included: inappropriate use of medicaments--overdose, use at unsuitable time (28.7 %), a need to inform the patient (17.6 %), potentially ineffective therapy (12.9 %), drug interactions (7.4 %), suspected and potential undesirable effects of prescribed medicaments (7.4 %), and insufficient compliance (6.5 %). Solution of problems with medicaments was most frequently: a change in dosage (25.9 %), recommendation to consult the physician (24.1 %), and professional counselling on pharmacotherapy (23.1 %). The pharmacotherapeutic group identified as the one most frequently requiring a telephone consultation of the pharmacist and the physician was antibiotics, including antibacterial chemotherapeutic agents.

  3. Task-focused modeling in automated agriculture

    Science.gov (United States)

    Vriesenga, Mark R.; Peleg, K.; Sklansky, Jack

    1993-01-01

    Machine vision systems analyze image data to carry out automation tasks. Our interest is in machine vision systems that rely on models to achieve their designed task. When the model is interrogated from an a priori menu of questions, the model need not be complete. Instead, the machine vision system can use a partial model that contains a large amount of information in regions of interest and less information elsewhere. We propose an adaptive modeling scheme for machine vision, called task-focused modeling, which constructs a model having just sufficient detail to carry out the specified task. The model is detailed in regions of interest to the task and is less detailed elsewhere. This focusing effect saves time and reduces the computational effort expended by the machine vision system. We illustrate task-focused modeling by an example involving real-time micropropagation of plants in automated agriculture.

  4. Development of alloy-film coated dispenser cathode for terahertz vacuum electron devices application

    International Nuclear Information System (INIS)

    Barik, R.K.; Bera, A.; Raju, R.S.; Tanwar, A.K.; Baek, I.K.; Min, S.H.; Kwon, O.J.; Sattorov, M.A.; Lee, K.W.; Park, G.-S.

    2013-01-01

    High power terahertz vacuum electron devices demand high current density and uniform emission dispenser cathode. It was found that the coating of noble metals e.g., Os, Ir, and Re on the surface of tungsten dispenser cathodes enhances the emission capabilities and uniformity. Hence metal coated cathode might be the best candidate for terahertz devices applications. In this study, ternary-alloy-film cathode (2Os:2Re:1 W) and Os coated cathode have been developed and the results are presented. The cathodes made out of this alloy coating showed 1.5 times higher emission and 0.02 eV emission uniformity as compared to those of simply Os coated cathodes which can be used in terahertz devices application.

  5. Development of alloy-film coated dispenser cathode for terahertz vacuum electron devices application

    Energy Technology Data Exchange (ETDEWEB)

    Barik, R. K.; Bera, A. [School of Electrical Engineering and Computer Science, Seoul National University, Seoul (Korea, Republic of); Raju, R. S. [Central Electronics Engineering Research Institute (CEERI), Rajasthan (India); Tanwar, A. K.; Baek, I. K.; Min, S. H.; Kwon, O. J.; Sattorov, M. A. [Department of Physics and Astronomy, Center for THz-Bio Application Systems, and Seoul-Teracom Inc., Seoul National University, Seoul (Korea, Republic of); Lee, K. W. [LIG Nex1, Seoul (Korea, Republic of); Park, G.-S., E-mail: gunsik@snu.ac.kr [School of Electrical Engineering and Computer Science, Seoul National University, Seoul (Korea, Republic of); Department of Physics and Astronomy, Center for THz-Bio Application Systems, and Seoul-Teracom Inc., Seoul National University, Seoul (Korea, Republic of); Advanced Institute of Convergence Technology, Suwon-si, Gyeonggi-do (Korea, Republic of)

    2013-07-01

    High power terahertz vacuum electron devices demand high current density and uniform emission dispenser cathode. It was found that the coating of noble metals e.g., Os, Ir, and Re on the surface of tungsten dispenser cathodes enhances the emission capabilities and uniformity. Hence metal coated cathode might be the best candidate for terahertz devices applications. In this study, ternary-alloy-film cathode (2Os:2Re:1 W) and Os coated cathode have been developed and the results are presented. The cathodes made out of this alloy coating showed 1.5 times higher emission and 0.02 eV emission uniformity as compared to those of simply Os coated cathodes which can be used in terahertz devices application.

  6. An enhanced biometric authentication scheme for telecare medicine information systems with nonce using chaotic hash function.

    Science.gov (United States)

    Das, Ashok Kumar; Goswami, Adrijit

    2014-06-01

    Recently, Awasthi and Srivastava proposed a novel biometric remote user authentication scheme for the telecare medicine information system (TMIS) with nonce. Their scheme is very efficient as it is based on efficient chaotic one-way hash function and bitwise XOR operations. In this paper, we first analyze Awasthi-Srivastava's scheme and then show that their scheme has several drawbacks: (1) incorrect password change phase, (2) fails to preserve user anonymity property, (3) fails to establish a secret session key beween a legal user and the server, (4) fails to protect strong replay attack, and (5) lacks rigorous formal security analysis. We then a propose a novel and secure biometric-based remote user authentication scheme in order to withstand the security flaw found in Awasthi-Srivastava's scheme and enhance the features required for an idle user authentication scheme. Through the rigorous informal and formal security analysis, we show that our scheme is secure against possible known attacks. In addition, we simulate our scheme for the formal security verification using the widely-accepted AVISPA (Automated Validation of Internet Security Protocols and Applications) tool and show that our scheme is secure against passive and active attacks, including the replay and man-in-the-middle attacks. Our scheme is also efficient as compared to Awasthi-Srivastava's scheme.

  7. Validation of a proxy for estrogen receptor status in breast cancer patients using dispensing data.

    Science.gov (United States)

    Srasuebkul, Preeyaporn; Dobbins, Timothy A; Pearson, Sallie-Anne

    2014-06-01

    To assess the performance of a proxy for estrogen receptor (ER) status in breast cancer patients using dispensing data. We derived our proxy using 167 patients. ER+ patients had evidence of at least one dispensing record for hormone therapy during the lookback period, irrespective of diagnosis date and ER- had no dispensing records for hormone therapy during the period. We validated the proxy against our gold standard, ER status from pathology reports or medical records. We assessed the proxy's performance using three lookback periods: 4.5 years, 2 years, 1 year. More than half of our cohort (62%) were >50 years, 54% had stage III/IV breast cancer at recruitment, (46%) were diagnosed with breast cancer in 2009 and 23% were diagnosed before 2006. Sensitivity and specificity were high for the 4.5 year lookback period (93%, 95% CI: 86-96%; and 95%: 83-99%), respectively) and remained high for the 2-year lookback period (91%: 84-95%; and 95%: 83-99%). Sensitivity decreased (83%: 75.2-89%) but specificity remained high (95%: 83-99%) using the 1-year lookback period and the period is long enough to allow sufficient time for hormone therapy to be dispensed. Our proxy accurately infers ER status in studies of breast cancer treatment based on secondary health data. The proxy is most robust with a minimum lookback period of 2 years. © 2012 Wiley Publishing Asia Pty Ltd.

  8. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    Science.gov (United States)

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  9. Treatment practices of households and antibiotic dispensing in medicine outlets in developing countries: The case of Ghana

    DEFF Research Database (Denmark)

    Tersbøl, Britt Pinkowski

    2018-01-01

    in households and the antibiotic dispensing practices of medicine sales outlets in Eastern region, Ghana. Method: Twice-weekly illness recall visits were made to 12 households in three rural communities over eight consecutive weeks. Detailed fieldnotes were taken and analysed using a thematic approach....... Quantitative counts of health events and treatment were also conducted. Dispensing practices were systematically observed and documented in three rural and three urban medicine outlets for analysis. Result: Fever, abdominal, and respiratory symptoms were the most common causes of ill-health in the 12...... an integral part of healthcare in the study settings and the qualitative data provides a contextual understanding of over-the-counter antibiotic acquisition and use. Inappropriate antibiotic use is apparent in the study settings. Stricter regulation of the pharmaceutical sector, training of dispensers...

  10. An Improved and Secure Biometric Authentication Scheme for Telecare Medicine Information Systems Based on Elliptic Curve Cryptography.

    Science.gov (United States)

    Chaudhry, Shehzad Ashraf; Mahmood, Khalid; Naqvi, Husnain; Khan, Muhammad Khurram

    2015-11-01

    Telecare medicine information system (TMIS) offers the patients convenient and expedite healthcare services remotely anywhere. Patient security and privacy has emerged as key issues during remote access because of underlying open architecture. An authentication scheme can verify patient's as well as TMIS server's legitimacy during remote healthcare services. To achieve security and privacy a number of authentication schemes have been proposed. Very recently Lu et al. (J. Med. Syst. 39(3):1-8, 2015) proposed a biometric based three factor authentication scheme for TMIS to confiscate the vulnerabilities of Arshad et al.'s (J. Med. Syst. 38(12):136, 2014) scheme. Further, they emphasized the robustness of their scheme against several attacks. However, in this paper we establish that Lu et al.'s scheme is vulnerable to numerous attacks including (1) Patient anonymity violation attack, (2) Patient impersonation attack, and (3) TMIS server impersonation attack. Furthermore, their scheme does not provide patient untraceability. We then, propose an improvement of Lu et al.'s scheme. We have analyzed the security of improved scheme using popular automated tool ProVerif. The proposed scheme while retaining the plusses of Lu et al.'s scheme is also robust against known attacks.

  11. A Review of the Anthropometric Characteristics, Grading and Dispensation of Junior and Youth Rugby Union Players in Australia.

    Science.gov (United States)

    Patton, Declan Alexander; McIntosh, Andrew Stuart; Denny, Greg

    2016-08-01

    The grading of Australian junior and youth rugby union players has received substantial media attention in recent years. Media reports have focussed on size mismatches observed between players, especially players with Polynesian heritage, and the concerned parents who fear for the safety of their child owing to perceived mismatches. Although such concerns are well meaning, few media reports recognise the need for substantial evidence to determine the best grading system for junior and youth rugby union players. The current study reviewed relevant literature pertinent to the grading and dispensation of junior and youth rugby union players. Using primary and secondary search strategies, a total of 33 articles reporting the anthropometric characteristics of junior and youth rugby players were identified. Anthropometric data from the literature were compared with normative population data and currently used dispensation criteria. Junior and youth rugby players were found to be taller and heavier than normative population data. Current dispensation criteria, in terms of body mass, were found to vary and it is suggested that criteria be revised and standardised across rugby unions throughout Australia. Although it is acknowledged that other factors are important for grading players, anthropometric characteristics should be considered as potential dispensation criteria to supplement current age-based grading for junior and youth rugby union players. Measuring the body mass and stature of each junior player upon pre-season registration is suggested, which would provide data to establish valid dispensation criteria for the following season.

  12. Design, microfabrication, and characterization of a moulded PDMS/SU-8 inkjet dispenser for a Lab-on-a-Printer platform technology with disposable microfluidic chip.

    Science.gov (United States)

    Bsoul, Anas; Pan, Sheng; Cretu, Edmond; Stoeber, Boris; Walus, Konrad

    2016-08-16

    In this paper, we present a disposable inkjet dispenser platform technology and demonstrate the Lab-on-a-Printer concept, an extension of the ubiquitous Lab-on-a-Chip concept, whereby microfluidic modules are directly integrated into the printhead. The concept is demonstrated here through the integration of an inkjet dispenser and a microfluidic mixer enabling control over droplet composition from a single nozzle in real-time during printing. The inkjet dispenser is based on a modular design platform that enables the low-cost microfluidic component and the more expensive actuation unit to be easily separated, allowing for the optional disposal of the former and reuse of the latter. To limit satellite droplet formation, a hydrophobic-coated and tapered micronozzle was microfabricated and integrated with the fluidics to realize the dispenser. The microfabricated devices generated droplets with diameters ranging from 150-220 μm, depending mainly on the orifice diameter, with printing rates up to 8000 droplets per second. The inkjet dispenser is capable of dispensing materials with a viscosity up to ∼19 mPa s. As a demonstration of the inkjet dispenser function and application, we have printed type I collagen seeded with human liver carcinoma cells (cell line HepG2), to form patterned biological structures.

  13. An improved and effective secure password-based authentication and key agreement scheme using smart cards for the telecare medicine information system.

    Science.gov (United States)

    Das, Ashok Kumar; Bruhadeshwar, Bezawada

    2013-10-01

    Recently Lee and Liu proposed an efficient password based authentication and key agreement scheme using smart card for the telecare medicine information system [J. Med. Syst. (2013) 37:9933]. In this paper, we show that though their scheme is efficient, their scheme still has two security weaknesses such as (1) it has design flaws in authentication phase and (2) it has design flaws in password change phase. In order to withstand these flaws found in Lee-Liu's scheme, we propose an improvement of their scheme. Our improved scheme keeps also the original merits of Lee-Liu's scheme. We show that our scheme is efficient as compared to Lee-Liu's scheme. Further, through the security analysis, we show that our scheme is secure against possible known attacks. In addition, we simulate our scheme for the formal security verification using the widely-accepted AVISPA (Automated Validation of Internet Security Protocols and Applications) tool to show that our scheme is secure against passive and active attacks.

  14. A Secure ECC-based RFID Mutual Authentication Protocol to Enhance Patient Medication Safety.

    Science.gov (United States)

    Jin, Chunhua; Xu, Chunxiang; Zhang, Xiaojun; Li, Fagen

    2016-01-01

    Patient medication safety is an important issue in patient medication systems. In order to prevent medication errors, integrating Radio Frequency Identification (RFID) technology into automated patient medication systems is required in hospitals. Based on RFID technology, such systems can provide medical evidence for patients' prescriptions and medicine doses, etc. Due to the mutual authentication between the medication server and the tag, RFID authentication scheme is the best choice for automated patient medication systems. In this paper, we present a RFID mutual authentication scheme based on elliptic curve cryptography (ECC) to enhance patient medication safety. Our scheme can achieve security requirements and overcome various attacks existing in other schemes. In addition, our scheme has better performance in terms of computational cost and communication overhead. Therefore, the proposed scheme is well suitable for patient medication systems.

  15. SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

    International Nuclear Information System (INIS)

    Covington, E; Younge, K; Chen, X; Lee, C; Matuszak, M; Kessler, M; Acosta, E; Orow, A; Filpansick, S; Moran, J; Keranen, W

    2015-01-01

    Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827

  16. SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

    Energy Technology Data Exchange (ETDEWEB)

    Covington, E; Younge, K; Chen, X; Lee, C; Matuszak, M; Kessler, M; Acosta, E; Orow, A; Filpansick, S; Moran, J [University of Michigan Hospital and Health System, Ann Arbor, MI (United States); Keranen, W [Varian Medical Systems, Palo Alto, CA (United States)

    2015-06-15

    Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827.

  17. Automated and electronically assisted hand hygiene monitoring systems: a systematic review.

    Science.gov (United States)

    Ward, Melissa A; Schweizer, Marin L; Polgreen, Philip M; Gupta, Kalpana; Reisinger, Heather S; Perencevich, Eli N

    2014-05-01

    Hand hygiene is one of the most effective ways to prevent transmission of health care-associated infections. Electronic systems and tools are being developed to enhance hand hygiene compliance monitoring. Our systematic review assesses the existing evidence surrounding the adoption and accuracy of automated systems or electronically enhanced direct observations and also reviews the effectiveness of such systems in health care settings. We systematically reviewed PubMed for articles published between January 1, 2000, and March 31, 2013, containing the terms hand AND hygiene or hand AND disinfection or handwashing. Resulting articles were reviewed to determine if an electronic system was used. We identified 42 articles for inclusion. Four types of systems were identified: electronically assisted/enhanced direct observation, video-monitored direct observation systems, electronic dispenser counters, and automated hand hygiene monitoring networks. Fewer than 20% of articles identified included calculations for efficiency or accuracy. Limited data are currently available to recommend adoption of specific automatic or electronically assisted hand hygiene surveillance systems. Future studies should be undertaken that assess the accuracy, effectiveness, and cost-effectiveness of such systems. Given the restricted clinical and infection prevention budgets of most facilities, cost-effectiveness analysis of specific systems will be required before these systems are widely adopted. Published by Mosby, Inc.

  18. An Energy Efficient Mutual Authentication and Key Agreement Scheme Preserving Anonymity for Wireless Sensor Networks

    Science.gov (United States)

    Lu, Yanrong; Li, Lixiang; Peng, Haipeng; Yang, Yixian

    2016-01-01

    WSNs (Wireless sensor networks) are nowadays viewed as a vital portion of the IoTs (Internet of Things). Security is a significant issue in WSNs, especially in resource-constrained environments. AKA (Authentication and key agreement) enhances the security of WSNs against adversaries attempting to get sensitive sensor data. Various AKA schemes have been developed for verifying the legitimate users of a WSN. Firstly, we scrutinize Amin-Biswas’s currently scheme and demonstrate the major security loopholes in their works. Next, we propose a lightweight AKA scheme, using symmetric key cryptography based on smart card, which is resilient against all well known security attacks. Furthermore, we prove the scheme accomplishes mutual handshake and session key agreement property securely between the participates involved under BAN (Burrows, Abadi and Needham) logic. Moreover, formal security analysis and simulations are also conducted using AVISPA(Automated Validation of Internet Security Protocols and Applications) to show that our scheme is secure against active and passive attacks. Additionally, performance analysis shows that our proposed scheme is secure and efficient to apply for resource-constrained WSNs. PMID:27338382

  19. An Energy Efficient Mutual Authentication and Key Agreement Scheme Preserving Anonymity for Wireless Sensor Networks.

    Science.gov (United States)

    Lu, Yanrong; Li, Lixiang; Peng, Haipeng; Yang, Yixian

    2016-06-08

    WSNs (Wireless sensor networks) are nowadays viewed as a vital portion of the IoTs (Internet of Things). Security is a significant issue in WSNs, especially in resource-constrained environments. AKA (Authentication and key agreement) enhances the security of WSNs against adversaries attempting to get sensitive sensor data. Various AKA schemes have been developed for verifying the legitimate users of a WSN. Firstly, we scrutinize Amin-Biswas's currently scheme and demonstrate the major security loopholes in their works. Next, we propose a lightweight AKA scheme, using symmetric key cryptography based on smart card, which is resilient against all well known security attacks. Furthermore, we prove the scheme accomplishes mutual handshake and session key agreement property securely between the participates involved under BAN (Burrows, Abadi and Needham) logic. Moreover, formal security analysis and simulations are also conducted using AVISPA(Automated Validation of Internet Security Protocols and Applications) to show that our scheme is secure against active and passive attacks. Additionally, performance analysis shows that our proposed scheme is secure and efficient to apply for resource-constrained WSNs.

  20. An Energy Efficient Mutual Authentication and Key Agreement Scheme Preserving Anonymity for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Yanrong Lu

    2016-06-01

    Full Text Available WSNs (Wireless sensor networks are nowadays viewed as a vital portion of the IoTs (Internet of Things. Security is a significant issue in WSNs, especially in resource-constrained environments. AKA (Authentication and key agreement enhances the security of WSNs against adversaries attempting to get sensitive sensor data. Various AKA schemes have been developed for verifying the legitimate users of a WSN. Firstly, we scrutinize Amin-Biswas’s currently scheme and demonstrate the major security loopholes in their works. Next, we propose a lightweight AKA scheme, using symmetric key cryptography based on smart card, which is resilient against all well known security attacks. Furthermore, we prove the scheme accomplishes mutual handshake and session key agreement property securely between the participates involved under BAN (Burrows, Abadi and Needham logic. Moreover, formal security analysis and simulations are also conducted using AVISPA(Automated Validation of Internet Security Protocols and Applications to show that our scheme is secure against active and passive attacks. Additionally, performance analysis shows that our proposed scheme is secure and efficient to apply for resource-constrained WSNs.

  1. Lyplal1 is dispensable for normal fat deposition in mice

    Directory of Open Access Journals (Sweden)

    Rachel A. Watson

    2017-12-01

    Full Text Available Genome-wide association studies (GWAS have detected association between variants in or near the Lysophospholipase-like 1 (LYPLAL1 locus and metabolic traits, including central obesity, fatty liver and waist-to-hip ratio. LYPLAL1 is also known to be upregulated in the adipose tissue of obese patients. However, the physiological role of LYPLAL1 is not understood. To investigate the function of Lyplal1 in vivo we investigated the phenotype of the Lyplal1tm1a(KOMPWtsi homozygous mouse. Body composition was unaltered in Lyplal1 knockout mice as assessed by dual-energy X-ray absorptiometry (DEXA scanning, both on normal chow and on a high-fat diet. Adipose tissue distribution between visceral and subcutaneous fat depots was unaltered, with no change in adipocyte cell size. The response to both insulin and glucose dosing was normal in Lyplal1tm1a(KOMPWtsi homozygous mice, with normal fasting blood glucose concentrations. RNAseq analysis of liver, muscle and adipose tissue confirmed that Lyplal1 expression was ablated with minimal additional changes in gene expression. These results suggest that Lyplal1 is dispensable for normal mouse metabolic physiology and that despite having been maintained through evolution Lyplal1 is not an essential gene, suggesting possible functional redundancy. Further studies will be required to clarify its physiological role.

  2. Recent trends in the dispensing of 90-day-supply prescriptions at retail pharmacies: implications for improved convenience and access.

    Science.gov (United States)

    Liberman, Joshua N; Girdish, Charmaine

    2011-03-01

    Mail-service pharmacies offer consumers the convenience of prescriptions filled with a 90-day supply of medication. Unlike mail-service pharmacies, retail pharmacies traditionally dispensed maintenance medication prescriptions with a 30-day supply. However, the retail landscape changed in May 2008 with Walmart's announcement of an extension of its $4 Prescription Program to include 90-day-supply prescriptions. To evaluate recent changes in access to and use of 90-day-supply maintenance medications dispensed via retail pharmacy. As of the first quarter of 2007, the proportion of retail-dispensed maintenance medications with a 90-day supply (compared with all maintenance prescriptions dispensed) among Medicare Part D plans, self-insured employers, and private health plans was 5.1%, 5.1%, and 5.0%, respectively. As of December 2009, this ratio had risen to 8.0% for Medicare plans and 8.1% for commercial health plans; the ratio among employers had risen more modestly to 6.1%. Of particular interest and importance, the proportion increased similarly for brand and for generic medications. There has been substantial growth in 90-day prescriptions dispensed via retail pharmacy, a trend that is likely to continue as more insurance providers adopt compatible benefit designs. It is important to continue monitoring these trends and to identify opportunities to rigorously evaluate their impact on medication adherence and healthcare costs.

  3. Calculational Tool for Skin Contamination Dose Assessment

    CERN Document Server

    Hill, R L

    2002-01-01

    Spreadsheet calculational tool was developed to automate the calculations preformed for dose assessment of skin contamination. This document reports on the design and testing of the spreadsheet calculational tool.

  4. Toward reliable and repeatable automated STEM-EDS metrology with high throughput

    Science.gov (United States)

    Zhong, Zhenxin; Donald, Jason; Dutrow, Gavin; Roller, Justin; Ugurlu, Ozan; Verheijen, Martin; Bidiuk, Oleksii

    2018-03-01

    New materials and designs in complex 3D architectures in logic and memory devices have raised complexity in S/TEM metrology. In this paper, we report about a newly developed, automated, scanning transmission electron microscopy (STEM) based, energy dispersive X-ray spectroscopy (STEM-EDS) metrology method that addresses these challenges. Different methodologies toward repeatable and efficient, automated STEM-EDS metrology with high throughput are presented: we introduce the best known auto-EDS acquisition and quantification methods for robust and reliable metrology and present how electron exposure dose impacts the EDS metrology reproducibility, either due to poor signalto-noise ratio (SNR) at low dose or due to sample modifications at high dose conditions. Finally, we discuss the limitations of the STEM-EDS metrology technique and propose strategies to optimize the process both in terms of throughput and metrology reliability.

  5. Automated personal dosimetry monitoring system for NPP

    International Nuclear Information System (INIS)

    Chanyshev, E.; Chechyotkin, N.; Kondratev, A.; Plyshevskaya, D.

    2006-01-01

    Full text: Radiation safety of personnel at nuclear power plants (NPP) is a priority aim. Degree of radiation exposure of personnel is defined by many factors: NPP design, operation of equipment, organizational management of radiation hazardous works and, certainly, safety culture of every employee. Automated Personal Dosimetry Monitoring System (A.P.D.M.S.) is applied at all nuclear power plants nowadays in Russia to eliminate the possibility of occupational radiation exposure beyond regulated level under different modes of NPP operation. A.P.D.M.S. provides individual radiation dose registration. In the paper the efforts of Design Bureau 'Promengineering' in construction of software and hardware complex of A.P.D.M.S. (S.H.W. A.P.D.M.S.) for NPP with PWR are presented. The developed complex is intended to automatize activities of radiation safety department when caring out individual dosimetry control. The complex covers all main processes concerning individual monitoring of external and internal radiation exposure as well as dose recording, management, and planning. S.H.W. A.P.D.M.S. is a multi-purpose system which software was designed on the modular approach. This approach presumes modification and extension of software using new components (modules) without changes in other components. Such structure makes the system flexible and allows modifying it in case of implementation a new radiation safety requirements and extending the scope of dosimetry monitoring. That gives the possibility to include with time new kinds of dosimetry control for Russian NPP in compliance with IAEA recommendations, for instance, control of the equivalent dose rate to the skin and the equivalent dose rate to the lens of the eye S.H.W. A.P.D.M.S. provides dosimetry control as follows: Current monitoring of external radiation exposure: - Gamma radiation dose measurement using radio-photoluminescent personal dosimeters. - Neutron radiation dose measurement using thermoluminescent

  6. Micronucleus test for radiation biodosimetry in mass casualty events: Evaluation of visual and automated scoring

    Energy Technology Data Exchange (ETDEWEB)

    Bolognesi, Claudia, E-mail: claudia.bolognesi@istge.i [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Balia, Cristina; Roggieri, Paola [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Cardinale, Francesco [Clinical Epidemiology Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Department of Health Sciences, University of Genoa, Genoa (Italy); Bruzzi, Paolo [Clinical Epidemiology Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Sorcinelli, Francesca [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Laboratory of Genetics, Histology and Molecular Biology Section, Army Medical and Veterinary, Research Center, Via Santo Stefano Rotondo 4, 00184 Roma (Italy); Lista, Florigio [Laboratory of Genetics, Histology and Molecular Biology Section, Army Medical and Veterinary, Research Center, Via Santo Stefano Rotondo 4, 00184 Roma (Italy); D' Amelio, Raffaele [Sapienza, Universita di Roma II Facolta di Medicina e Chirurgia and Ministero della Difesa, Direzione Generale Sanita Militare (Italy); Righi, Enzo [Frascati National Laboratories, National Institute of Nuclear Physics, Via Enrico Fermi 40, 00044 Frascati, Rome (Italy)

    2011-02-15

    In the case of a large-scale nuclear or radiological incidents a reliable estimate of dose is an essential tool for providing timely assessment of radiation exposure and for making life-saving medical decisions. Cytogenetics is considered as the 'gold standard' for biodosimetry. The dicentric analysis (DA) represents the most specific cytogenetic bioassay. The micronucleus test (MN) applied in interphase in peripheral lymphocytes is an alternative and simpler approach. A dose-effect calibration curve for the MN frequency in peripheral lymphocytes from 27 adult donors was established after in vitro irradiation at a dose range 0.15-8 Gy of {sup 137}Cs gamma rays (dose rate 6 Gy min{sup -1}). Dose prediction by visual scoring in a dose-blinded study (0.15-4.0 Gy) revealed a high level of accuracy (R = 0.89). The scoring of MN is time consuming and requires adequate skills and expertise. Automated image analysis is a feasible approach allowing to reduce the time and to increase the accuracy of the dose estimation decreasing the variability due to subjective evaluation. A good correlation (R = 0.705) between visual and automated scoring with visual correction was observed over the dose range 0-2 Gy. Almost perfect discrimination power for exposure to 1-2 Gy, and a satisfactory power for 0.6 Gy were detected. This threshold level can be considered sufficient for identification of sub lethally exposed individuals by automated CBMN assay.

  7. Measurement of microbic contamination rate in the dispensing process making suspension of barium sulfate powder

    International Nuclear Information System (INIS)

    Kim, Young Keun; Lee, Yang Sub; Cho, Cheong Chan; Ryu, Meung Sun; Lee, Kyung Sup

    2001-01-01

    The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus coli were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured. Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensable to manufacturing suspension for preventing from infection

  8. What makes an automated teller machine usable by blind users?

    Science.gov (United States)

    Manzke, J M; Egan, D H; Felix, D; Krueger, H

    1998-07-01

    Fifteen blind and sighted subjects, who featured as a control group for acceptance, were asked for their requirements for automated teller machines (ATMs). Both groups also tested the usability of a partially operational ATM mock-up. This machine was based on an existing cash dispenser, providing natural speech output, different function menus and different key arrangements. Performance and subjective evaluation data of blind and sighted subjects were collected. All blind subjects were able to operate the ATM successfully. The implemented speech output was the main usability factor for them. The different interface designs did not significantly affect performance and subjective evaluation. Nevertheless, design recommendations can be derived from the requirement assessment. The sighted subjects were rather open for design modifications, especially the implementation of speech output. However, there was also a mismatch of the requirements of the two subject groups, mainly concerning the key arrangement.

  9. Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

    Science.gov (United States)

    Jacobson, Stephen C [Knoxville, TN; Ramsey, J Michael [Knoxville, TN

    2008-09-09

    A microfluidic device and method for forming and dispensing minute volume segments of a material are described. In accordance with the present invention, a microfluidic device and method are provided for spatially confining the material in a focusing element. The device is also adapted for segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

  10. Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications

    International Nuclear Information System (INIS)

    Rosu, Mihaela; Chetty, Indrin J.; Balter, James M.; Kessler, Marc L.; McShan, Daniel L.; Ten Haken, Randall K.

    2005-01-01

    In this study we investigated the accumulation of dose to a deforming anatomy (such as lung) based on voxel tracking and by using time weighting factors derived from a breathing probability distribution function (p.d.f.). A mutual information registration scheme (using thin-plate spline warping) provided a transformation that allows the tracking of points between exhale and inhale treatment planning datasets (and/or intermediate state scans). The dose distributions were computed at the same resolution on each dataset using the Dose Planning Method (DPM) Monte Carlo code. Two accumulation/interpolation approaches were assessed. The first maps exhale dose grid points onto the inhale scan, estimates the doses at the 'tracked' locations by trilinear interpolation and scores the accumulated doses (via the p.d.f.) on the original exhale data set. In the second approach, the 'volume' associated with each exhale dose grid point (exhale dose voxel) is first subdivided into octants, the center of each octant is mapped to locations on the inhale dose grid and doses are estimated by trilinear interpolation. The octant doses are then averaged to form the inhale voxel dose and scored at the original exhale dose grid point location. Differences between the interpolation schemes are voxel size and tissue density dependent, but in general appear primarily only in regions with steep dose gradients (e.g., penumbra). Their magnitude (small regions of few percent differences) is less than the alterations in dose due to positional and shape changes from breathing in the first place. Thus, for sufficiently small dose grid point spacing, and relative to organ motion and deformation, differences due solely to the interpolation are unlikely to result in clinically significant differences to volume-based evaluation metrics such as mean lung dose (MLD) and tumor equivalent uniform dose (gEUD). The overall effects of deformation vary among patients. They depend on the tumor location, field

  11. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    Science.gov (United States)

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  12. Five years' experience of occupational radiation dose reduction in positron emission tomography-computed tomography imaging at Prince Sultan Military Medical City

    International Nuclear Information System (INIS)

    Alenezi, Ahmed; Soliman, Khaled

    2016-01-01

    The number of installed PET/CT scanners is increasing leading to an increased workload which could result in higher radiation dose received by nuclear medicine workers responsible for conducting the imaging studies in clinical environment. An effort should be made to further optimize the current dose reduction methods employed to achieve 'as low as reasonably achievable' (ALARA) levels. The aim of this work is to provide an overview of the recent techniques used to reduce the occupational radiation doses in PET/CT practice. The worker radiation dose in PET/ CT is higher than in conventional nuclear medicine practice. The higher radiation dose is mainly from the high energy annihilation photons. The highest radiation exposures to the involved staff occur during the dispensing, injection of the Radiopharmaceuticals and performing direct communications with the injected patients at close range. During the period of five years of PET/CT practice at Prince Sultan military medical city (PSMMC) in Saudi Arabia, we have implemented several methods for staff dose optimization. The methods included the following: (1) Training and experience of PET/CT staff, (2) use of time of flight (TOF) technology, (3) optimized design and layout of the department, (4) use of lead shields and automatic dispensing/injection systems. The results from implementing the dose optimization methods are reflected on the staff occupational dose records by a reduction of 55% over a period of 5 years. The presented data can be applied to optimize radiation protection practices during PET/CT imaging procedures. (author)

  13. Pharmacy Malpractice: The rate and prevalence of dispensing high-risk prescription-only medications at community pharmacies in Saudi Arabia.

    Science.gov (United States)

    Alshammari, Thamir M; Alhindi, Salman A; Alrashdi, Ahmed M; Benmerzouga, Imaan; Aljofan, Mohamad

    2017-07-01

    To assess the compliance of community pharmacies with the regulations that prohibit the dispensing of prescription-only medications in the absence of a physician prescription in Saudi Arabia. A cross-sectional study was conducted in the period between October 2014 and January 2015. A list of 10 prescription-only medications were selected to be studied. 150 community pharmacies were visited across 6 major regions in Saudi Arabia to assess the prevalence of non-compliance among community pharmacies. Pharmacies were selected in random and researchers (disguised as patients) requested to purchase prescription-only medications in the absence of a prescription. Not all medications were purchased at once. Data were recorded per pharmacy, where pharmacies that approved dispense of the selected drug were scored as non-compliant and the pharmacies that rejected dispense of the selected drug were scored as compliant. Compliance rate was calculated per region per drug. Pharmacies based in governmental hospitals were visited in parallel. A total of 20 were visited. Data and statistical analysis were performed using Statistical Analyses Software (SAS 9.3). A total of 150 pharmacies were visited over a period of 3 months. On average, the percent approved dispense of prescription-only drugs across 6 regions in Saudi Arabia is 63% and the percent rejected dispense is 37% representing a significant non-compliance rate regarding the selected list of medications in this study. The frequency of dispense per medication across 6 major regions in Saudi Arabia is as follows: Isosorbide dinitrate (86%), Enoxaparin (82%), nitroglycerin (74%), Propranolol (73%), Verapamil (70%), Warfarin (65%), Methyldopa (64%), Ciprofloxacin (57%) and Codeine (4%). Non-compliance of community pharmacies with the law of pharmaceutical practice is at an alarming rate in the Kingdom of Saudi Arabia and authoritative figures must intervene to impede and combat such activities .

  14. Polymer dispensing and embossing technology for the lens type LED packaging

    Science.gov (United States)

    Chien, Chien-Lin Chang; Huang, Yu-Che; Hu, Syue-Fong; Chang, Chung-Min; Yip, Ming-Chuen; Fang, Weileun

    2013-06-01

    This study presents a ring-type micro-structure design on the substrate and its corresponding micro fabrication processes for a lens-type light-emitting diode (LED) package. The dome-type or crater-type silicone lenses are achieved by a dispensing and embossing process rather than a molding process. Silicone with a high viscosity and thixotropy index is used as the encapsulant material. The ring-type micro structure is adopted to confine the dispensed silicone encapsulant so as to form the packaged lens. With the architecture and process described, this LED package technology herein has three merits: (1) the flexibility of lens-type LED package designs is enhanced; (2) a dome-type package design is used to enhance the intensity; (3) a crater-type package design is used to enhance the view angle. Measurement results show the ratio between the lens height and lens radius can vary from 0.4 to 1 by changing the volume of dispensed silicone. The view angles of dome-type and crater-type packages can reach 155° ± 5° and 175° ± 5°, respectively. As compared with the commercial plastic leaded chip carrier-type package, the luminous flux of a monochromatic blue light LED is improved by 15% by the dome-type package (improved by 7% by the crater-type package) and the luminous flux of a white light LED is improved by 25% by the dome-type package (improved by 13% by the crater-type package). The luminous flux of monochromatic blue light LED and white light LED are respectively improved by 8% and 12% by the dome-type package as compare with the crater-type package.

  15. In defence of collective dose

    International Nuclear Information System (INIS)

    Fairlie, I.; Sumner, D.

    2000-01-01

    Recent proposals for a new scheme of radiation protection leave little room for collective dose estimations. This article discusses the history and present use of collective doses for occupational, ALARA, EIS and other purposes with reference to practical industry papers and government reports. The linear no-threshold (LNT) hypothesis suggests that collective doses which consist of very small doses added together should be used. Moral and ethical questions are discussed, particularly the emphasis on individual doses to the exclusion of societal risks, uncertainty over effects into the distant future and hesitation over calculating collective detriments. It is concluded that for moral, practical and legal reasons, collective dose is a valid parameter which should continue to be used. (author)

  16. Dose prescription in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gupta, N.M.S.; Gahbauer, R.A.; Blue, T.E.; Wambersie, A.

    1994-01-01

    The purpose of this paper is to address some aspects of the many considerations that need to go into a dose prescription in boron neutron capture therapy (BNCT) for brain tumors; and to describe some methods to incorporate knowledge from animal studies and other experiments into the process of dose prescription. Previously, an algorithm to estimate the normal tissue tolerance to mixed high and low linear energy transfer radiations in BNCT was proposed. The authors have developed mathematical formulations and computational methods to represent this algorithm. Generalized models to fit the central axis dose rate components for an epithermal neutron field were also developed. These formulations and beam fitting models were programmed into spreadsheets to simulate two treatment techniques which are expected to be used in BNCT: a two-field bilateral scheme and a single-field treatment scheme. Parameters in these spreadsheets can be varied to represent the fractionation scheme used, the 10 B microdistribution in normal tissue, and the ratio of 10 B in tumor to normal tissue. Most of these factors have to be determined for a given neutron field and 10 B compound combination from large animal studies. The spreadsheets have been programmed to integrate all of the treatment-related information and calculate the location along the central axis where the normal tissue tolerance is exceeded first. This information is then used to compute the maximum treatment time allowable and the maximum tumor dose that may be delivered for a given BNCT treatment. The effect of different treatment variables on the treatment time and tumor dose has been shown to be very significant. It has also been shown that the location of D max shifts significantly, depending on some of the treatment variables-mainly the fractionation scheme used. These results further emphasize the fact that dose prescription in BNCT is very complicated and nonintuitive. 11 refs., 6 figs., 3 tabs

  17. Automation of the dicentric chromosome assay and related assays

    International Nuclear Information System (INIS)

    Balajee, Adayabalam S.; Dainiak, Nicholas

    2016-01-01

    Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed

  18. Automated assembly of fast-axis collimation (FAC) lenses for diode laser bar modules

    Science.gov (United States)

    Miesner, Jörn; Timmermann, Andre; Meinschien, Jens; Neumann, Bernhard; Wright, Steve; Tekin, Tolga; Schröder, Henning; Westphalen, Thomas; Frischkorn, Felix

    2009-02-01

    Laser diodes and diode laser bars are key components in high power semiconductor lasers and solid state laser systems. During manufacture, the assembly of the fast axis collimation (FAC) lens is a crucial step. The goal of our activities is to design an automated assembly system for high volume production. In this paper the results of an intermediate milestone will be reported: a demonstration system was designed, realized and tested to prove the feasibility of all of the system components and process features. The demonstration system consists of a high precision handling system, metrology for process feedback, a powerful digital image processing system and tooling for glue dispensing, UV curing and laser operation. The system components as well as their interaction with each other were tested in an experimental system in order to glean design knowledge for the fully automated assembly system. The adjustment of the FAC lens is performed by a series of predefined steps monitored by two cameras concurrently imaging the far field and the near field intensity distributions. Feedback from these cameras processed by a powerful and efficient image processing algorithm control a five axis precision motion system to optimize the fast axis collimation of the laser beam. Automated cementing of the FAC to the diode bar completes the process. The presentation will show the system concept, the algorithm of the adjustment as well as experimental results. A critical discussion of the results will close the talk.

  19. Additive operator-difference schemes splitting schemes

    CERN Document Server

    Vabishchevich, Petr N

    2013-01-01

    Applied mathematical modeling isconcerned with solving unsteady problems. This bookshows how toconstruct additive difference schemes to solve approximately unsteady multi-dimensional problems for PDEs. Two classes of schemes are highlighted: methods of splitting with respect to spatial variables (alternating direction methods) and schemes of splitting into physical processes. Also regionally additive schemes (domain decomposition methods)and unconditionally stable additive schemes of multi-component splitting are considered for evolutionary equations of first and second order as well as for sy

  20. Automation of cell-based drug absorption assays in 96-well format using permeable support systems.

    Science.gov (United States)

    Larson, Brad; Banks, Peter; Sherman, Hilary; Rothenberg, Mark

    2012-06-01

    Cell-based drug absorption assays, such as Caco-2 and MDCK-MDR1, are an essential component of lead compound ADME/Tox testing. The permeability and transport data they provide can determine whether a compound continues in the drug discovery process. Current methods typically incorporate 24-well microplates and are performed manually. Yet the need to generate absorption data earlier in the drug discovery process, on an increasing number of compounds, is driving the use of higher density plates. A simple, more efficient process that incorporates 96-well permeable supports and proper instrumentation in an automated process provides more reproducible data compared to manual methods. Here we demonstrate the ability to perform drug permeability and transport assays using Caco-2 or MDCKII-MDR1 cells. The assay procedure was automated in a 96-well format, including cell seeding, media and buffer exchanges, compound dispense, and sample removal using simple robotic instrumentation. Cell monolayer integrity was confirmed via transepithelial electrical resistance and Lucifer yellow measurements. Proper cell function was validated by analyzing apical-to-basolateral and basolateral-to-apical movement of rhodamine 123, a known P-glycoprotein substrate. Apparent permeability and efflux data demonstrate how the automated procedure provides a less variable method than manual processing, and delivers a more accurate assessment of a compound's absorption characteristics.

  1. What do Australian consumers, pharmacists and prescribers think about documenting indications on prescriptions and dispensed medicines labels?: A qualitative study.

    Science.gov (United States)

    Garada, Mona; McLachlan, Andrew J; Schiff, Gordon D; Lehnbom, Elin C

    2017-11-15

    Documenting the indication on prescriptions and dispensed medicines labels is not standard practice in Australia. However, previous studies that have focused on the content and design of dispensed medicines labels, have suggested including the indication as a safety measure. The aim of this study was to investigate the perspectives of Australian consumers, pharmacists and prescribers on documenting the indication on prescriptions and dispensed medicines labels. Semi-structured interviews were conducted and mock-up of dispensed medicines labels were designed for participants. Consumers (n = 19) and pharmacists (n = 7) were recruited by convenience sample at community pharmacies in Sydney (Australia) and prescribers (n = 8), including two medical students, were recruited through snowballing. Thirty-four participants were interviewed. Most participants agreed that documenting the indication would be beneficial especially for patients who are forgetful or take multiple medications. Participants also believed it would improve consumers' medication understanding and adherence. Prescribers and pharmacists believed it could help reduce prescribing and dispensing errors by matching the drug/dosage to the correct indication. Prescribers refrained from documenting the indication to protect patients' privacy; however, most patients did not consider documenting the indication as a breach of privacy. Prescribers raised concerns about the extra time to include indications on prescriptions and best language to document indications, using plain language as opposed to medical terminology. All interviewed stakeholders identified numerous benefits of documenting the indication on prescriptions and dispensed medicines labels. Whether these potential benefits can be realized remains unknown and addressing prescribers' concern regarding the time involved in documenting the indication on prescriptions remains a challenge for vendors of electronic medication management systems.

  2. What do Australian consumers, pharmacists and prescribers think about documenting indications on prescriptions and dispensed medicines labels?: A qualitative study

    Directory of Open Access Journals (Sweden)

    Mona Garada

    2017-11-01

    Full Text Available Abstract Background Documenting the indication on prescriptions and dispensed medicines labels is not standard practice in Australia. However, previous studies that have focused on the content and design of dispensed medicines labels, have suggested including the indication as a safety measure. The aim of this study was to investigate the perspectives of Australian consumers, pharmacists and prescribers on documenting the indication on prescriptions and dispensed medicines labels. Methods Semi-structured interviews were conducted and mock-up of dispensed medicines labels were designed for participants. Consumers (n = 19 and pharmacists (n = 7 were recruited by convenience sample at community pharmacies in Sydney (Australia and prescribers (n = 8, including two medical students, were recruited through snowballing. Results Thirty-four participants were interviewed. Most participants agreed that documenting the indication would be beneficial especially for patients who are forgetful or take multiple medications. Participants also believed it would improve consumers’ medication understanding and adherence. Prescribers and pharmacists believed it could help reduce prescribing and dispensing errors by matching the drug/dosage to the correct indication. Prescribers refrained from documenting the indication to protect patients’ privacy; however, most patients did not consider documenting the indication as a breach of privacy. Prescribers raised concerns about the extra time to include indications on prescriptions and best language to document indications, using plain language as opposed to medical terminology. Conclusions All interviewed stakeholders identified numerous benefits of documenting the indication on prescriptions and dispensed medicines labels. Whether these potential benefits can be realized remains unknown and addressing prescribers’ concern regarding the time involved in documenting the indication on prescriptions

  3. Concern about the Expanding Prescription Drug Epidemic: A Survey of Licensed Prescribers and Dispensers.

    Science.gov (United States)

    Wright, R Eric; Reed, Nia; Carnes, Neal; Kooreman, Harold E

    2016-01-01

    Prescription drug misuse and abuse has reached epidemic levels in the U.S., and stands as a leading cause of death. As the primary gatekeepers to the medications contributing to this epidemic, it is critical to understand the views of licensed health care professionals. In this study, we examine health care professionals' concern regarding prescription drug abuse in their communities and the impact their concern has had on their prescribing and dispensing practices. An online survey of licensed health care providers. Conducted in Indiana. This study was a state-wide evaluation of Indiana's prescription drug monitoring program. The questionnaire asked respondents how concerned they were about prescription drug abuse in their community. Variation in the level of concern was examined using ordinary least squares regression and information about the respondents' demographic background and clinical experience. In addition, we used logistic regression to examine whether concern was associated with changing prescribing and/or dispensing behavior. The majority of providers indicated they were "moderately" or "extremely concerned" about prescription drug abuse in their communities. The level of concern, however, varied significantly by profession, with pharmacists, physicians, nurse practitioners/physician assistants being more concerned than dentists. Additional analyses indicate that providers with higher levels of concern were those who also reported recently changing their prescribing and/or dispensing behavior. The voluntary nature and geographical focus of the study limits the generalizability of the findings. Concern about prescription drug abuse is generally high across the major health care professions; however, a significant minority of providers, particularly among dentists, expressed little or no concern about the epidemic. Increasing health care providers' general level of concern about prescription drug abuse may be an effective public health tool for

  4. An enhanced password authentication scheme for session initiation protocol with perfect forward secrecy.

    Science.gov (United States)

    Qiu, Shuming; Xu, Guoai; Ahmad, Haseeb; Guo, Yanhui

    2018-01-01

    The Session Initiation Protocol (SIP) is an extensive and esteemed communication protocol employed to regulate signaling as well as for controlling multimedia communication sessions. Recently, Kumari et al. proposed an improved smart card based authentication scheme for SIP based on Farash's scheme. Farash claimed that his protocol is resistant against various known attacks. But, we observe some accountable flaws in Farash's protocol. We point out that Farash's protocol is prone to key-compromise impersonation attack and is unable to provide pre-verification in the smart card, efficient password change and perfect forward secrecy. To overcome these limitations, in this paper we present an enhanced authentication mechanism based on Kumari et al.'s scheme. We prove that the proposed protocol not only overcomes the issues in Farash's scheme, but it can also resist against all known attacks. We also provide the security analysis of the proposed scheme with the help of widespread AVISPA (Automated Validation of Internet Security Protocols and Applications) software. At last, comparing with the earlier proposals in terms of security and efficiency, we conclude that the proposed protocol is efficient and more secure.

  5. An enhanced password authentication scheme for session initiation protocol with perfect forward secrecy

    Science.gov (United States)

    2018-01-01

    The Session Initiation Protocol (SIP) is an extensive and esteemed communication protocol employed to regulate signaling as well as for controlling multimedia communication sessions. Recently, Kumari et al. proposed an improved smart card based authentication scheme for SIP based on Farash’s scheme. Farash claimed that his protocol is resistant against various known attacks. But, we observe some accountable flaws in Farash’s protocol. We point out that Farash’s protocol is prone to key-compromise impersonation attack and is unable to provide pre-verification in the smart card, efficient password change and perfect forward secrecy. To overcome these limitations, in this paper we present an enhanced authentication mechanism based on Kumari et al.’s scheme. We prove that the proposed protocol not only overcomes the issues in Farash’s scheme, but it can also resist against all known attacks. We also provide the security analysis of the proposed scheme with the help of widespread AVISPA (Automated Validation of Internet Security Protocols and Applications) software. At last, comparing with the earlier proposals in terms of security and efficiency, we conclude that the proposed protocol is efficient and more secure. PMID:29547619

  6. Exponential discontinuous numerical scheme for electron transport in the continuous slowing down approximation

    International Nuclear Information System (INIS)

    Prinja, A.K.

    1997-01-01

    A nonlinear discretization scheme in space and energy, based on the recently developed exponential discontinuous method, is applied to continuous slowing down dominated electron transport (i.e., in the absence of scattering.) Numerical results for dose and charge deposition are obtained and compared against results from the ONELD and ONEBFP codes, and against exact results from an adjoint Monte Carlo code. It is found that although the exponential discontinuous scheme yields strictly positive and monotonic solutions, the dose profile is considerably straggled when compared to results from the linear codes. On the other hand, the linear schemes produce negative results which, furthermore, do not damp effectively in some cases. A general conclusion is that while yielding strictly positive solutions, the exponential discontinuous method does not show the crude cell accuracy for charged particle transport as was apparent for neutral particle transport problems

  7. Understanding vs. Competency: The Case of Accuracy Checking Dispensed Medicines in Pharmacy

    Science.gov (United States)

    James, K. Lynette; Davies, J. Graham; Kinchin, Ian; Patel, Jignesh P.; Whittlesea, Cate

    2010-01-01

    Ensuring the competence of healthcare professionals' is core to undergraduate and post-graduate education. Undergraduate pharmacy students and pre-registration graduates are required to demonstrate competence at dispensing and accuracy checking medicines. However, competence differs from understanding. This study determined the competence and…

  8. Estimation of urinary stone composition by automated processing of CT images.

    Science.gov (United States)

    Chevreau, Grégoire; Troccaz, Jocelyne; Conort, Pierre; Renard-Penna, Raphaëlle; Mallet, Alain; Daudon, Michel; Mozer, Pierre

    2009-10-01

    The objective of this article was developing an automated tool for routine clinical practice to estimate urinary stone composition from CT images based on the density of all constituent voxels. A total of 118 stones for which the composition had been determined by infrared spectroscopy were placed in a helical CT scanner. A standard acquisition, low-dose and high-dose acquisitions were performed. All voxels constituting each stone were automatically selected. A dissimilarity index evaluating variations of density around each voxel was created in order to minimize partial volume effects: stone composition was established on the basis of voxel density of homogeneous zones. Stone composition was determined in 52% of cases. Sensitivities for each compound were: uric acid: 65%, struvite: 19%, cystine: 78%, carbapatite: 33.5%, calcium oxalate dihydrate: 57%, calcium oxalate monohydrate: 66.5%, brushite: 75%. Low-dose acquisition did not lower the performances (P < 0.05). This entirely automated approach eliminates manual intervention on the images by the radiologist while providing identical performances including for low-dose protocols.

  9. The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before-and-after study.

    Science.gov (United States)

    Franklin, Bryony Dean; O'Grady, Kara; Donyai, Parastou; Jacklin, Ann; Barber, Nick

    2007-08-01

    To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (pMedical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; chi(2) test). A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.

  10. INVESTIGATION OF DYNAMIC CHARACTERISTICS OF ELEMENTS OF AUTOMATICS OF A SMART HOUSE IN PARAMETRICAL STRUCTURAL SCHEMES

    Directory of Open Access Journals (Sweden)

    Petrova Irina Yur’evna

    2018-01-01

    Full Text Available Subject: automation of calculation of dynamic characteristics of the device being designed in the system of conceptual design of sensor equipment, structurally-parametric models of dynamic processes and algorithms for the automated calculation of the qualitative characteristics of elements of the information-measuring and control systems (IMCS. The stage of conceptual design most fully determines the operational characteristics of technical systems. However, none of the information support systems of this stage provides an opportunity to evaluate the performance characteristics of the element being designed taking into account its dynamic characteristics. Research objectives: increasing the effectiveness of the evaluation of dynamic characteristics of sensitive elements of the information-measuring and control systems of a smart house. Materials and methods: when solving the problems posed, the mathematical apparatus of system modeling was used (in particular, the energy-information method of modeling processes of various physical nature that occur in the sensor equipment; the main provisions of the theory of automatic control, the theory of constructing computer-aided design systems, the theory of operational calculus; basics of conceptual design of elements of the information-measuring and control systems. Results: we compared the known automated systems for conceptual design of sensors, highlighted their advantages and disadvantages and we showed that none of these systems allows us to investigate dynamic characteristics of the element being designed in a simple and understandable for engineer form. The authors proposed using energy-information method of modeling for the synthesis of operation principles of sensors and analysis of their dynamic characteristics. We considered elementary dynamic chains and issues of synthesis of parametrical structural schemes that reflect the dynamics of the process with the use of mathematical apparatus of

  11. Automated planning of breast radiotherapy using cone beam CT imaging

    International Nuclear Information System (INIS)

    Amit, Guy; Purdie, Thomas G.

    2015-01-01

    Purpose: Develop and clinically validate a methodology for using cone beam computed tomography (CBCT) imaging in an automated treatment planning framework for breast IMRT. Methods: A technique for intensity correction of CBCT images was developed and evaluated. The technique is based on histogram matching of CBCT image sets, using information from “similar” planning CT image sets from a database of paired CBCT and CT image sets (n = 38). Automated treatment plans were generated for a testing subset (n = 15) on the planning CT and the corrected CBCT. The plans generated on the corrected CBCT were compared to the CT-based plans in terms of beam parameters, dosimetric indices, and dose distributions. Results: The corrected CBCT images showed considerable similarity to their corresponding planning CTs (average mutual information 1.0±0.1, average sum of absolute differences 185 ± 38). The automated CBCT-based plans were clinically acceptable, as well as equivalent to the CT-based plans with average gantry angle difference of 0.99°±1.1°, target volume overlap index (Dice) of 0.89±0.04 although with slightly higher maximum target doses (4482±90 vs 4560±84, P < 0.05). Gamma index analysis (3%, 3 mm) showed that the CBCT-based plans had the same dose distribution as plans calculated with the same beams on the registered planning CTs (average gamma index 0.12±0.04, gamma <1 in 99.4%±0.3%). Conclusions: The proposed method demonstrates the potential for a clinically feasible and efficient online adaptive breast IMRT planning method based on CBCT imaging, integrating automation

  12. High-throughput mouse genotyping using robotics automation.

    Science.gov (United States)

    Linask, Kaari L; Lo, Cecilia W

    2005-02-01

    The use of mouse models is rapidly expanding in biomedical research. This has dictated the need for the rapid genotyping of mutant mouse colonies for more efficient utilization of animal holding space. We have established a high-throughput protocol for mouse genotyping using two robotics workstations: a liquid-handling robot to assemble PCR and a microfluidics electrophoresis robot for PCR product analysis. This dual-robotics setup incurs lower start-up costs than a fully automated system while still minimizing human intervention. Essential to this automation scheme is the construction of a database containing customized scripts for programming the robotics workstations. Using these scripts and the robotics systems, multiple combinations of genotyping reactions can be assembled simultaneously, allowing even complex genotyping data to be generated rapidly with consistency and accuracy. A detailed protocol, database, scripts, and additional background information are available at http://dir.nhlbi.nih.gov/labs/ldb-chd/autogene/.

  13. Emission characteristics of dispenser cathodes with a fine-grained tungsten top layer

    Science.gov (United States)

    Kimura, S.; Higuchi, T.; Ouchi, Y.; Uda, E.; Nakamura, O.; Sudo, T.; Koyama, K.

    1997-02-01

    In order to improve the emission stability of the Ir-coated dispenser cathode under ion bombardment, a fine-grained tungsten top layer was applied on the substrate porous tungsten plug before Ir coating. The emission characteristics were studied after being assembled in a CRT gun. Cathode current was measured under pulse operation in a range of 0.1-9% duty. Remarkable anti-ion bombardment characteristics were observed over the range of 1-6% duty. The improved cathode showed 1.5 times higher emission current than that of a conventional Ir-coated dispenser cathode at 4% duty. AES analysis showed that the recovering rates of surface Ba and O atoms after ion bombardment were 2.5 times higher. From these results it is confirmed that the Ir coated cathode with a fine-grained tungsten top layer is provided with a good tolerance against the ion bombardment.

  14. Automation of closed environments in space for human comfort and safety

    Science.gov (United States)

    1992-01-01

    This report culminates the work accomplished during a three year design project on the automation of an Environmental Control and Life Support System (ECLSS) suitable for space travel and colonization. The system would provide a comfortable living environment in space that is fully functional with limited human supervision. A completely automated ECLSS would increase astronaut productivity while contributing to their safety and comfort. The first section of this report, section 1.0, briefly explains the project, its goals, and the scheduling used by the team in meeting these goals. Section 2.0 presents an in-depth look at each of the component subsystems. Each subsection describes the mathematical modeling and computer simulation used to represent that portion of the system. The individual models have been integrated into a complete computer simulation of the CO2 removal process. In section 3.0, the two simulation control schemes are described. The classical control approach uses traditional methods to control the mechanical equipment. The expert control system uses fuzzy logic and artificial intelligence to control the system. By integrating the two control systems with the mathematical computer simulation, the effectiveness of the two schemes can be compared. The results are then used as proof of concept in considering new control schemes for the entire ECLSS. Section 4.0 covers the results and trends observed when the model was subjected to different test situations. These results provide insight into the operating procedures of the model and the different control schemes. The appendix, section 5.0, contains summaries of lectures presented during the past year, homework assignments, and the completed source code used for the computer simulation and control system.

  15. Automated calculation of point A coordinates for CT-based high-dose-rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Hyejoo Kang

    2017-07-01

    Full Text Available Purpose: The goal is to develop a stand-alone application, which automatically and consistently computes the coordinates of the dose calculation point recommended by the American Brachytherapy Society (i.e., point A based solely on the implanted applicator geometry for cervical cancer brachytherapy. Material and methods: The application calculates point A coordinates from the source dwell geometries in the computed tomography (CT scans, and outputs the 3D coordinates in the left and right directions. The algorithm was tested on 34 CT scans of 7 patients treated with high-dose-rate (HDR brachytherapy using tandem and ovoid applicators. A single experienced user retrospectively and manually inserted point A into each CT scan, whose coordinates were used as the “gold standard” for all comparisons. The gold standard was subtracted from the automatically calculated points, a second manual placement by the same experienced user, and the clinically used point coordinates inserted by multiple planners. Coordinate differences and corresponding variances were compared using nonparametric tests. Results: Automatically calculated, manually placed, and clinically used points agree with the gold standard to < 1 mm, 1 mm, 2 mm, respectively. When compared to the gold standard, the average and standard deviation of the 3D coordinate differences were 0.35 ± 0.14 mm from automatically calculated points, 0.38 ± 0.21 mm from the second manual placement, and 0.71 ± 0.44 mm from the clinically used point coordinates. Both the mean and standard deviations of the 3D coordinate differences were statistically significantly different from the gold standard, when point A was placed by multiple users (p < 0.05 but not when placed repeatedly by a single user or when calculated automatically. There were no statistical differences in doses, which agree to within 1-2% on average for all three groups. Conclusions: The study demonstrates that the automated algorithm

  16. Adaptation of a T3-uptake test and of radioimmunoassays for serum digoxin, thyroxine, and triiodothyronine to an automated radioimmunoassay system: ''Centria''

    International Nuclear Information System (INIS)

    Ertingshausen, G.; Shapiro, S.I.; Green, G.; Zborowski, G.

    1975-01-01

    We report the adaptation of four radioassays to the prototype of an automated radioimmunoassay system (''Centria,'' Union Carbide). The system consists of three integrated modules: an automated pipettor, which dispenses samples and reagents; the key module, an incubator/separator, in which centrifugal force is used to initiate and terminate multiple radioassay incubations and separations simultaneously; and a gamma-counter/computer, which counts three tubes simultaneously and converts counts into concentration units. Radioimmunoassays for thyroxine, triiodothyronine, and digoxin were developed with use of well-characterized antibodies and of prepackaged Sephadex-containing columns to separate bound and free radioactive ligand. A triiodothyronine-uptake test in which the same kind of columns were used was also adapted to the instrument. Results for clinical samples compared favorably with those obtained by manual procedures. We report data on correlation between different methods and preliminary data on precision of the prototype system

  17. Multiobjective hyper heuristic scheme for system design and optimization

    Science.gov (United States)

    Rafique, Amer Farhan

    2012-11-01

    As system design is becoming more and more multifaceted, integrated, and complex, the traditional single objective optimization trends of optimal design are becoming less and less efficient and effective. Single objective optimization methods present a unique optimal solution whereas multiobjective methods present pareto front. The foremost intent is to predict a reasonable distributed pareto-optimal solution set independent of the problem instance through multiobjective scheme. Other objective of application of intended approach is to improve the worthiness of outputs of the complex engineering system design process at the conceptual design phase. The process is automated in order to provide the system designer with the leverage of the possibility of studying and analyzing a large multiple of possible solutions in a short time. This article presents Multiobjective Hyper Heuristic Optimization Scheme based on low level meta-heuristics developed for the application in engineering system design. Herein, we present a stochastic function to manage meta-heuristics (low-level) to augment surety of global optimum solution. Generic Algorithm, Simulated Annealing and Swarm Intelligence are used as low-level meta-heuristics in this study. Performance of the proposed scheme is investigated through a comprehensive empirical analysis yielding acceptable results. One of the primary motives for performing multiobjective optimization is that the current engineering systems require simultaneous optimization of conflicting and multiple. Random decision making makes the implementation of this scheme attractive and easy. Injecting feasible solutions significantly alters the search direction and also adds diversity of population resulting in accomplishment of pre-defined goals set in the proposed scheme.

  18. Immediate or deferred adjustment of drug regimens in multidose drug dispensing systems.

    Science.gov (United States)

    Mertens, Bram J; Kwint, Henk-Frans; van Marum, Rob J; Bouvy, Marcel L

    2018-05-18

    Multidose drug dispensing (MDD) is used to help patients take their medicines appropriately. Little is known about drug regimen changes within these MDD systems and how they are effectuated by the community pharmacist. Manual immediate adjustments of the MDD system could introduce dispensing errors. MDD guidelines therefore recommend to effectuate drug regimen changes at the start of a new MDD system. The aim of this study was to investigate the frequency, type, procedure followed, immediate necessity, and time taken to make MDD adjustments. This was a cross-sectional study in eight community pharmacies in the Netherlands. All adjustments to MDD systems were systematically documented for 3 weeks by the community pharmacist. Overall, 261 MDD adjustments involving 364 drug changes were documented for 250 patients: 127 (35%) drug changes involved the addition of a new drug, 124 (34%) a change in dosage, and 95 (26%) drug discontinuation. Of the MDD adjustments, 135 (52%) were effectuated immediately: 81 (31%) by adjusting the MDD system manually, 49 (19%) by temporarily dispensing the drug separately from the MDD system, and 5 (2%) by ordering a new MDD system. Pharmacists considered that 36 (27%) of the immediate MDD adjustments could have been deferred until the next MDD system was produced. Immediate adjustment took significantly longer than deferred adjustment (p < 0.001). This study shows that in patients using MDD systems, over half of the drug regimen changes are adjusted immediately. The necessity of these immediate changes should be critically evaluated. Copyright © 2018. Published by Elsevier Inc.

  19. Near real-time automated dose restoration in IMPT to compensate for daily tissue density variations in prostate cancer

    Science.gov (United States)

    Jagt, Thyrza; Breedveld, Sebastiaan; van de Water, Steven; Heijmen, Ben; Hoogeman, Mischa

    2017-06-01

    Proton therapy is very sensitive to daily density changes along the pencil beam paths. The purpose of this study is to develop and evaluate an automated method for adaptation of IMPT plans to compensate for these daily tissue density variations. A two-step restoration method for ‘densities-of-the-day’ was created: (1) restoration of spot positions (Bragg peaks) by adapting the energy of each pencil beam to the new water equivalent path length; and (2) re-optimization of pencil beam weights by minimizing the dosimetric difference with the planned dose distribution, using a fast and exact quadratic solver. The method was developed and evaluated using 8-10 repeat CT scans of 10 prostate cancer patients. Experiments demonstrated that giving a high weight to the PTV in the re-optimization resulted in clinically acceptable restorations. For all scans we obtained V 95%  ⩾  98% and V 107%  ⩽  2%. For the bladder, the differences between the restored and the intended treatment plan were below  +2 Gy and  +2%-point. The rectum differences were below  +2 Gy and  +2%-point for 90% of the scans. In the remaining scans the rectum was filled with air, which partly overlapped with the PTV. The air cavity distorted the Bragg peak resulting in less favorable rectum doses.

  20. Subsidising patient dispensing fees: the cost of injecting equity into the opioid pharmacotherapy maintenance system.

    Science.gov (United States)

    Chalmers, Jenny; Ritter, Alison

    2012-11-01

    Australian pharmacotherapy maintenance programs incur costs to patients. These dispensing fees represent a financial burden to patients and are inconsistent with Australian health-care principles. No previous work has examined the current costs nor the future predicted costs if government subsidised dispensing fees. A system dynamics model, which simulated the flow of patients into and out of methadone maintenance treatment, was developed. Costs were imputed from existing research data. The approach enabled simulation of possible behavioural responses to a fee subsidy (such as higher retention) and new estimates of costs were derived under such scenarios. Current modelled costs (AUS$11.73m per month) were largely borne by state/territory government (43%), with patients bearing one-third (33%) of the total costs and the Commonwealth one-quarter (24%). Assuming no behavioural changes associated with fee subsidies, the cost of subsidising the dispensing fees of Australian methadone patients would be $3.9m per month. If retention were improved as a result of fee subsidy, treatment numbers would increase and the model estimates an additional cost of $0.8m per month. If this was coupled with greater numbers entering treatment, the costs would increase by a further $0.4m per month. In total, full fee subsidy with modelled behavioural changes would increase per annum government expenditure by $81.8m to $175.8m. If government provided dispensing fee relief for methadone maintenance patients, it would be a costly exercise. However, these additional costs are offset by the social and health gains achieved from the methadone maintenance program. © 2012 Australasian Professional Society on Alcohol and other Drugs.

  1. Automation of complex assays: pharmacogenetics of warfarin dosing.

    Science.gov (United States)

    Wu, Whei-Kuo; Hujsak, Paul G; Kureshy, Fareed

    2007-10-01

    AutoGenomics, Inc. (Carlsbad, CA, USA) have developed a multiplex microarray assay for genotyping both VKORC1 and CYP2C9 using the INFINITI(™) Analyzer. Multiple alleles in each DNA sample are analyzed by polymerase chain reaction amplification, followed by detection primer extension using the INFINITI Analyzer. The INFINITI Analyzer performs single-nucleotide polymorphism (SNP) analysis using universal oligonucleotides immobilized on the biochip. To genotype broader ethnic groups, genomic DNA from whole blood was tested for nine SNPs for VKORC1 and six for CYP2C9 genotypes. Information related to all 15 SNPs is needed to determine dosing of population of diverse ethnic origin. The INFINITI system provides genotyping information for same day dosing of warfarin.

  2. FPGA-Based Real-Time Motion Detection for Automated Video Surveillance Systems

    Directory of Open Access Journals (Sweden)

    Sanjay Singh

    2016-03-01

    Full Text Available Design of automated video surveillance systems is one of the exigent missions in computer vision community because of their ability to automatically select frames of interest in incoming video streams based on motion detection. This research paper focuses on the real-time hardware implementation of a motion detection algorithm for such vision based automated surveillance systems. A dedicated VLSI architecture has been proposed and designed for clustering-based motion detection scheme. The working prototype of a complete standalone automated video surveillance system, including input camera interface, designed motion detection VLSI architecture, and output display interface, with real-time relevant motion detection capabilities, has been implemented on Xilinx ML510 (Virtex-5 FX130T FPGA platform. The prototyped system robustly detects the relevant motion in real-time in live PAL (720 × 576 resolution video streams directly coming from the camera.

  3. Automation of Tabular Application Formation

    Directory of Open Access Journals (Sweden)

    S. V. Zykin

    2013-01-01

    Full Text Available The paper considers automation problems of the interface formation between a table and a relational database. The task description is formalized and the description of the existing approaches to formation of data representations on an example of widely widespread CASE-tools is submitted. The definition of intermediate data representation as a ”join table” is offered, which is used for maintenance of correctness of data representation formation, and also is necessary for direct and inverse data transformations. On the basis of lossless join property and realized dependencies, the concept and a way of context formation of the application and restrictions is introduced. The considered material is further used for constructing an inverse data transformation from tabular presentation into a relational one. On the basis of relationships properties on a database scheme, the partial order on the relations is established, and the restriction of acyclic databases schemes is introduced. The received results are further used at the analysis of principles of formation of inverse data transformation, and the basic details of such a transformation algorithm are considered.

  4. A Curriculum For Dispensing Optician A Case Study In Vietnam

    Directory of Open Access Journals (Sweden)

    Duong Dieu MD

    2015-08-01

    Full Text Available Until 2011 there had been no full-time training course for dispensing optician diploma in Vietnam. Most of the practicing opticians with no qualification and formal training have learnt their skills through apprentice. In response to the demand of the industry Nguyen Tat Thanh University Vietnam has teamed up with Bradford College United Kingdom to develop a curriculum for a of formal 2-year full-time training for dispensing optician. The curriculum is applied for 4 semesters and graduate gets called Intermediate Professional Diploma level included 4 semesters. In VN after high school students can obtain different many levels of study such as Intermediate Professional Diploma College Bachelor Master and PhD. The 1st semester is basis of Intermediate Professional Diploma level. The 2nd semester is the study of refractive error and primary care each for 4 weeks 100 hours in theory and primary eye care 4 weeks for theory 100 hours. Also in this semester the learners have practiced clinical rotation at the Ophthalmic Hospital Ophthalmic Service in General Hospital for 10 weeks. The 3rd semester is specialized of dispensing Optician included Lenses frame contact lenses and laboratory for optician. In the 4th semester the training concentrates in the management of the eyeglasses shop and practicing in making spectacles for customers are in the 4th semester. The 1st intake of the course was opened started in 2011 and had 30 students graduated in 2013. This paper describes the experience of developing the curriculum in the context of a developing country where the industry is still under regulated and less developed. The first program optician that privileged on primary eye care will be satisfied for community WHO 2020 1 optometrist for 50.000 people and 10 ophthalmologists for 1.000.000 people. Some characteristics of first course students have been noted. The result of this curriculum will be evaluated in the coming time.

  5. Mathematical modelling for dose deposition in photon-therapy

    International Nuclear Information System (INIS)

    Pichard, Teddy

    2016-01-01

    Radiotherapy treatments consists in irradiating the patient with beams of energetic particles (typically photons) targeting the tumor. Such particles are transported through the medium and deposit energy in the medium. This deposited energy is the so called dose, responsible for the biological effect of the radiations. The present work aim to develop numerical methods for dose computation and optimization that are competitive in terms of computational cost and accuracy compared to reference method. The motion of particles is first studied through a system of linear transport equations at the kinetic level. However, solving directly such systems is numerically too costly for medical application. Instead, the moment method is used with a special focus on the Mn models. Those moment equations are non-linear and valid under a condition called realizability. Standard numerical schemes for moment equations are constrained by stability conditions which happen to be very restrictive when the medium contains low density regions. Inconditionally stable numerical schemes adapted to moment equations (preserving the realizability property) are developed. Those schemes are shown to be competitive in terms of computational costs compared to reference approaches. Finally they are applied to in an optimization procedure aiming to maximize the dose in the tumor and to minimize the dose in healthy tissues. (author) [fr

  6. The degree of integration of non-dispensing pharmacists in primary care practice and the impact on health outcomes: A systematic review.

    Science.gov (United States)

    Hazen, Ankie C M; de Bont, Antoinette A; Boelman, Lia; Zwart, Dorien L M; de Gier, Johan J; de Wit, Niek J; Bouvy, Marcel L

    2018-03-01

    A non-dispensing pharmacist conducts clinical pharmacy services aimed at optimizing patients individual pharmacotherapy. Embedding a non-dispensing pharmacist in primary care practice enables collaboration, probably enhancing patient care. The degree of integration of non-dispensing pharmacists into multidisciplinary health care teams varies strongly between settings. The degree of integration may be a determinant for its success. This study investigates how the degree of integration of a non-dispensing pharmacist impacts medication related health outcomes in primary care. In this literature review we searched two electronic databases and the reference list of published literature reviews for studies about clinical pharmacy services performed by non-dispensing pharmacists physically co-located in primary care practice. We assessed the degree of integration via key dimensions of integration based on the conceptual framework of Walshe and Smith. We included English language studies of any design that had a control group or baseline comparison published from 1966 to June 2016. Descriptive statistics were used to correlate the degree of integration to health outcomes. The analysis was stratified for disease-specific and patient-centered clinical pharmacy services. Eighty-nine health outcomes in 60 comparative studies contributed to the analysis. The accumulated evidence from these studies shows no impact of the degree of integration of non-dispensing pharmacists on health outcomes. For disease specific clinical pharmacy services the percentage of improved health outcomes for none, partial and fully integrated NDPs is respectively 75%, 63% and 59%. For patient-centered clinical pharmacy services the percentage of improved health outcomes for none, partial and fully integrated NDPs is respectively 55%, 57% and 70%. Full integration adds value to patient-centered clinical pharmacy services, but not to disease-specific clinical pharmacy services. To obtain maximum benefits

  7. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5% compared with branded and generic prednisolone acetate ophthalmic suspension (1%

    Directory of Open Access Journals (Sweden)

    Marlowe ZT

    2013-12-01

    Full Text Available Zora T Marlowe, Stephen R DavioPharmaceutical Product Development, Global Pharmaceutical Research and Development, Bausch and Lomb, Inc, Rochester, NY, USAIntroduction: Loteprednol etabonate (LE ophthalmic gel 0.5% (Lotemax® is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte® and a generic prednisolone acetate suspension 1% were used as comparators.Methods: Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing – consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC method and reported as a percentage of the declared (labeled concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity.Results: Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD] percent declared concentration of 102% (1.92% over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively, with mean concentrations for both falling significantly

  8. Dose classification scheme for computed tomography of the paranasal sinuses

    International Nuclear Information System (INIS)

    Hojreh, A.; Czerny, C.; Kainberger, F.

    2005-01-01

    Purpose: The purpose of this study was to define objective and reproducible standards for the quality of CT images as a function of radiation doses and therapeutic validity. Materials and methods: CT images of the paranasal sinuses of 145 patients (77 female, 68 male; 5-83 years old; mean age, 39.9 years) were classified both subjectively (with a view toward their validity for the planning of functional endoscopic sinus surgery, FESS) and objectively by defining the pixel noise (the standard deviation, STD, of the CT number) in a homogeneous region of interest (ROI), centered on the M. masseter and on the frontal lobe. These measurements were then compared to measurements obtained from scan images of a water-filled Perspex phantom. Results: The pixel noise measured in the phantom images was nearly identical to the respective values on the M. masseter on the patient images. The use of an edge-enhancing reconstruction algorithm and low-dose protocols, with a pixel noise amounting to 70-90 Hounsfield Units (HU), are indicated for children, chronic sinusitis, and septum deviation, while standard protocols, with a pixel noise of 50-70 HU, are recommended for the preoperative planning and postoperative control of FESS. The pixel noise for high-dose protocols is less than 50 HU; nonetheless, such protocols should generally be avoided. Conclusion: The pixel noise measured in a water-filled Perspex phantom is indicative of the clinical potential and image quality of paranasal sinus CT scans. Alternatively, the M. masseter can be chosen as an ROI to measure the pixel noise in order to obtain a rough estimate of the image quality or radiation dose class

  9. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Poole, Zachary B.; Varga-Szemes, Akos; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Canstein, Christian [Siemens Medical Solutions, Malvern, PA (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Bamberg, Fabian; Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2016-10-15

    To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3{sup rd} generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥.0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p <.0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥.0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤.0414). Correlation analysis showed a moderate association between tube voltage and BMI (r =.639). ATVS allows individual tube voltage adaptation for CCTA performed with 3{sup rd} generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. (orig.)

  10. A new fully automated TLD badge reader

    International Nuclear Information System (INIS)

    Kannan, S.; Ratna, P.; Kulkarni, M.S.

    2003-01-01

    At present personnel monitoring in India is being carried out using a number of manual and semiautomatic TLD badge Readers and the BARC TL dosimeter badge designed during 1970. Of late the manual TLD badge readers are almost completely replaced by semiautomatic readers with a number of performance improvements like use of hot gas heating to reduce the readout time considerably. PC based design with storage of glow curve for every dosimeter, on-line dose computation and printout of dose reports, etc. However the semiautomatic system suffers from the lack of a machine readable ID code on the badge and the physical design of the dosimeter card not readily compatible for automation. This paper describes a fully automated TLD badge Reader developed in the RSS Division, using a new TLD badge with machine readable ID code. The new PC based reader has a built-in reader for reading the ID code, in the form of an array of holes, on the dosimeter card. The reader has a number of self-diagnostic features to ensure a high degree of reliability. (author)

  11. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5%) compared with branded and generic prednisolone acetate ophthalmic suspension (1%).

    Science.gov (United States)

    Marlowe, Zora T; Davio, Stephen R

    2014-01-01

    Loteprednol etabonate (LE) ophthalmic gel 0.5% (Lotemax®) is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte®) and a generic prednisolone acetate suspension 1% were used as comparators. Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing - consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC) method and reported as a percentage of the declared (labeled) concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity. Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD]) percent declared concentration of 102% (1.92%) over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively), with mean concentrations for both falling significantly below the declared concentration for drops expressed at the beginning of the 2-week dosing regimen and significantly above the declared concentration for drops expressed near the end of the dosing

  12. Methodological challenges in assessment of current use of warfarin among patients with atrial fibrillation using dispensation data from administrative health care databases.

    Science.gov (United States)

    Sinyavskaya, Liliya; Matteau, Alexis; Johnson, Sarasa; Durand, Madeleine

    2018-06-05

    Algorithms to define current exposure to warfarin using administrative data may be imprecise. Study objectives were to characterize dispensation patterns, to measure gaps between expected and observed refill dates for warfarin and direct oral anticoagulants (DOACs). Retrospective cohort study using administrative health care databases of the Régie de l'assurance-maladie du Québec. We identified every dispensation of warfarin, dabigatran, rivaroxaban, or apixaban for patients with AF initiating oral anticoagulants between 2010 and 2015. For each dispensation, we extracted date and duration. Refill gaps were calculated as difference between expected and observed dates of successive dispensation. Refill gaps were summarized using descriptive statistics. To account for repeated observations nested within patients and to assess the components of variance of refill gaps, we used unconditional multilevel linear models. We identified 61 516 new users. Majority were prescribed warfarin (60.3%), followed by rivaroxaban (16.4%), dabigatran (14.5%), apixaban (8.8%). Most frequent recorded duration of dispensation was 7 days, suggesting use of pharmacist-prepared weekly pillboxes. The average refill gap from multilevel model was higher for warfarin (9.28 days, 95%CI:8.97-9.59) compared with DOACs (apixaban 3.08 days, 95%CI: 2.96-3.20, dabigatran 3.70, 95%CI: 3.56-3.84, rivaroxaban 3.15, 95%CI: 3.03-3.27). The variance of refill gaps was greater among warfarin users than among DOAC users. Greater refill gaps for warfarin may reflect inadequate capture of the period covered by the number of dispensed pills recorded in administrative data. A time-dependent definition of exposure using dispensation data would lead to greater misclassification of warfarin than DOACs use. Copyright © 2018 John Wiley & Sons, Ltd.

  13. Virtual commissioning of automated micro-optical assembly

    Science.gov (United States)

    Schlette, Christian; Losch, Daniel; Haag, Sebastian; Zontar, Daniel; Roßmann, Jürgen; Brecher, Christian

    2015-02-01

    In this contribution, we present a novel approach to enable virtual commissioning for process developers in micro-optical assembly. Our approach aims at supporting micro-optics experts to effectively develop assisted or fully automated assembly solutions without detailed prior experience in programming while at the same time enabling them to easily implement their own libraries of expert schemes and algorithms for handling optical components. Virtual commissioning is enabled by a 3D simulation and visualization system in which the functionalities and properties of automated systems are modeled, simulated and controlled based on multi-agent systems. For process development, our approach supports event-, state- and time-based visual programming techniques for the agents and allows for their kinematic motion simulation in combination with looped-in simulation results for the optical components. First results have been achieved for simply switching the agents to command the real hardware setup after successful process implementation and validation in the virtual environment. We evaluated and adapted our system to meet the requirements set by industrial partners-- laser manufacturers as well as hardware suppliers of assembly platforms. The concept is applied to the automated assembly of optical components for optically pumped semiconductor lasers and positioning of optical components for beam-shaping

  14. Guide to Permitting Hydrogen Motor Fuel Dispensing Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, Carl [National Renewable Energy Lab. (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-28

    The purpose of this guide is to assist project developers, permitting officials, code enforcement officials, and other parties involved in developing permit applications and approving the implementation of hydrogen motor fuel dispensing facilities. The guide facilitates the identification of the elements to be addressed in the permitting of a project as it progresses through the approval process; the specific requirements associated with those elements; and the applicable (or potentially applicable) codes and standards by which to determine whether the specific requirements have been met. The guide attempts to identify all applicable codes and standards relevant to the permitting requirements.

  15. An approach to evaluate task allocation between operators and automation with respect to safety of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Macwan, A.; Wei, Z.G.; Wieringa, P.A.

    1994-01-01

    Even though the use of automation is increasing in complex systems, its effect on safety cannot be systematically analyzed using current techniques. Of particular interest is task allocation between operators and automation. In evaluating its effect on safety, a quantitative definition of degree of automation (doA) is used. The definition of doA accounts for the effect of task on safety, irrespective of whether the task is carried out by operator or automation. Also included is the indirect effect due to the change in workload perceived by the operator. This workload is translated into stress which affects operator performance, expressed as human error probability, and subsequently, safety. The approach can be useful for evaluation of existing task allocation schemes as well as in making decisions about task allocation between operators and automation. (author). 13 refs, 1 fig

  16. Automated VMAT planning for postoperative adjuvant treatment of advanced gastric cancer.

    Science.gov (United States)

    Sharfo, Abdul Wahab M; Stieler, Florian; Kupfer, Oskar; Heijmen, Ben J M; Dirkx, Maarten L P; Breedveld, Sebastiaan; Wenz, Frederik; Lohr, Frank; Boda-Heggemann, Judit; Buergy, Daniel

    2018-04-23

    Postoperative/adjuvant radiotherapy of advanced gastric cancer involves a large planning target volume (PTV) with multi-concave shapes which presents a challenge for volumetric modulated arc therapy (VMAT) planning. This study investigates the advantages of automated VMAT planning for this site compared to manual VMAT planning by expert planners. For 20 gastric cancer patients in the postoperative/adjuvant setting, dual-arc VMAT plans were generated using fully automated multi-criterial treatment planning (autoVMAT), and compared to manually generated VMAT plans (manVMAT). Both automated and manual plans were created to deliver a median dose of 45 Gy to the PTV using identical planning and segmentation parameters. Plans were evaluated by two expert radiation oncologists for clinical acceptability. AutoVMAT and manVMAT plans were also compared based on dose-volume histogram (DVH) and predicted normal tissue complication probability (NTCP) analysis. Both manVMAT and autoVMAT plans were considered clinically acceptable. Target coverage was similar (manVMAT: 96.6 ± 1.6%, autoVMAT: 97.4 ± 1.0%, p = 0.085). With autoVMAT, median kidney dose was reduced on average by > 25%; (for left kidney from 11.3 ± 2.1 Gy to 8.9 ± 3.5 Gy (p = 0.002); for right kidney from 9.2 ± 2.2 Gy to 6.1 ± 1.3 Gy (p plans (4.2% and 9.1%, respectively; p plans compared to manVMAT plans, the predicted NTCPs for the left and right kidney and the liver-PTV were significantly reduced by 11.3%, 12.8%, 7%, respectively (p ≤ 0.001). Delivery time and total number of monitor units were increased in autoVMAT plans (from 168 ± 19 s to 207 ± 26 s, p = 0.006) and (from 781 ± 168 MU to 1001 ± 134 MU, p = 0.003), respectively. For postoperative/adjuvant radiotherapy of advanced gastric cancer, involving a complex target shape, automated VMAT planning is feasible and can substantially reduce the dose to the kidneys and the liver

  17. Automated Prediction of Catalytic Mechanism and Rate Law Using Graph-Based Reaction Path Sampling.

    Science.gov (United States)

    Habershon, Scott

    2016-04-12

    In a recent article [ J. Chem. Phys. 2015 , 143 , 094106 ], we introduced a novel graph-based sampling scheme which can be used to generate chemical reaction paths in many-atom systems in an efficient and highly automated manner. The main goal of this work is to demonstrate how this approach, when combined with direct kinetic modeling, can be used to determine the mechanism and phenomenological rate law of a complex catalytic cycle, namely cobalt-catalyzed hydroformylation of ethene. Our graph-based sampling scheme generates 31 unique chemical products and 32 unique chemical reaction pathways; these sampled structures and reaction paths enable automated construction of a kinetic network model of the catalytic system when combined with density functional theory (DFT) calculations of free energies and resultant transition-state theory rate constants. Direct simulations of this kinetic network across a range of initial reactant concentrations enables determination of both the reaction mechanism and the associated rate law in an automated fashion, without the need for either presupposing a mechanism or making steady-state approximations in kinetic analysis. Most importantly, we find that the reaction mechanism which emerges from these simulations is exactly that originally proposed by Heck and Breslow; furthermore, the simulated rate law is also consistent with previous experimental and computational studies, exhibiting a complex dependence on carbon monoxide pressure. While the inherent errors of using DFT simulations to model chemical reactivity limit the quantitative accuracy of our calculated rates, this work confirms that our automated simulation strategy enables direct analysis of catalytic mechanisms from first principles.

  18. Automated system for review of radiotherapy treatment sheets

    International Nuclear Information System (INIS)

    Collado Chamorro, P.; Sanz Freire, C. J.; Vazquez Galinanes, A.; Diaz Pascual, V.; Gomez amez, J.; Martinez Sanchez, S.; Ossola Lentati, G. A.

    2011-01-01

    In many modern radiotherapy services begins to leaf treatment implemented in electronic form. In our department has developed an automated reporting system, that check the following parameters: treatment completed correctly, number of sessions and cumulative dose administered. Likewise treatments are verified in the allocated separate unit, and over-writing table parameters.

  19. Evaluation of antibiotics dispensing profile in Tubarão, Santa Catarina, Brazil

    Directory of Open Access Journals (Sweden)

    Claudia Rauber

    2009-12-01

    Full Text Available Antibiotics are drugs widely used in prophylaxis and treatment of a great number of diseases. However, their use must be carefully controlled as acquisition in pharmacies, often without medical prescription, is elevated. The role of pharmacists in these circumstances is to practice dispensation in a rational manner. Through a structured questionnaire with open and closed questions, this study investigated the profile of antibiotics dispensed in pharmacies of Tubarão, Santa Catarina, Brazil. From the responses, it was observed that 85.0% dispense this class of medicine without medical prescription, mainly for treatment of respiratory (62.8% and urinary (12.0% tract disorders. Moreover, pharmacists' guidance was largely focused on posology (66.6% and drug interaction (12.6%, in addition to the interactions with contraceptives, alcohol and milk. The importance of avoiding antibiotics dispensation without medical prescription must be emphasized, as well as the benefits of educating the population to promote the rational use of medicines.Antibióticos são fármacos amplamente utilizados na profilaxia e no tratamento de grande número de doenças. Entretanto, seu uso deve ser cuidadosamente controlado nas farmácias, uma vez que nestas a aquisição sem prescrição médica é elevada. O papel dos farmacêuticos nessas circunstâncias é o de praticar a dispensação de maneira racional. Por meio de questionário estruturado, com questões abertas e fechadas, investigou-se o perfil dos antibióticos dispensados em farmácias de Tubarão, Santa Catarina, Brasil. Pelas respostas, observou-se que 85% das dispensa essa classe de medicamentos sem prescrição médica, principalmente para o tratamento de problemas dos tratos respiratório (62,8% e urinário (12,0%. Além disso, a orientação dos farmacêuticos se focou amplamente na posologia (66,6%e nas interações com fármacos (12,6%, em adição às interações com anticoncepcionais, álcool e

  20. Optimizing clinical trial supply requirements: simulation of computer-controlled supply chain management.

    Science.gov (United States)

    Peterson, Magnus; Byrom, Bill; Dowlman, Nikki; McEntegart, Damian

    2004-01-01

    Computer-controlled systems are commonly used in clinical trials to control dispensing and manage site inventories of trial supplies. Typically such systems are used with an interactive telephone or web system that provide an interface with the study site. Realizing the maximum savings in medication associated with this approach has, in the past, been problematic as it has been difficult to fully estimate medication requirements due to the complexities of these algorithms and the inherent variation in the clinical trial recruitment process. We describe the traditional and automated methods of supplying sites. We detail a simulation approach that models the automated system. We design a number of simulation experiments using this model to investigate the supply strategy properties that influence medication overage and other strategy performance metrics. The computer-controlled medication system gave superior performance to the traditional method. In one example, a 75% overage of wasted medication in the traditional system was associated with higher supply failure than an automated system strategy with an overage of 47%. In a further example, we demonstrate that the impact of using a country stratified as opposed to site stratified scheme affects the number of deliveries and probability of supply failures more than the amount of drug wasted with respective increases of 20, 2300 and 4%. Medication savings with automated systems are particularly significant in repeat dispensing designs. We show that the number of packs required can fall by as much as 50% if one uses a predictive medication algorithm. We conclude that a computer-controlled supply chain enables medication savings to be realized and that it is possible to quantify the distribution of these savings using a simulation model. The simulation model can be used to optimize the prestudy medication supply strategy and for midstudy monitoring using real-time data contained in the study database.

  1. Prostate Dose Escalation by a Innovative Inverse Planning-Driven IMRT

    National Research Council Canada - National Science Library

    Xing, Lei

    2008-01-01

    ...) Developed a voxel-specific penalty scheme for TRV-based inverse planning; (iv) Established a cine-EPID image retrospective dose reconstruction in IMRT dose delivery for adaptive planning and IMRT dose verification. These works are both timely and important and should lead to widespread impact on prostate cancer management.

  2. Inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser.

    Science.gov (United States)

    Verkouteren, R Michael; Verkouteren, Jennifer R

    2009-10-15

    We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 microg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies.

  3. Data exchange technology based on handshake protocol for industrial automation system

    Science.gov (United States)

    Astafiev, A. V.; Shardin, T. O.

    2018-05-01

    In the article, questions of data exchange technology based on the handshake protocol for industrial automation system are considered. The methods of organizing the technology in client-server applications are analyzed. In the process of work, the main threats of client-server applications that arise during the information interaction of users are indicated. Also, a comparative analysis of analogue systems was carried out, as a result of which the most suitable option was chosen for further use. The basic schemes for the operation of the handshake protocol are shown, as well as the general scheme of the implemented application, which describes the entire process of interaction between the client and the server.

  4. Flow Channel Influence of a Collision-Based Piezoelectric Jetting Dispenser on Jet Performance

    Directory of Open Access Journals (Sweden)

    Can Zhou

    2018-04-01

    Full Text Available To improve the jet performance of a bi-piezoelectric jet dispenser, mathematical and simulation models were established according to the operating principle. In order to improve the accuracy and reliability of the simulation calculation, a viscosity model of the fluid was fitted to a fifth-order function with shear rate based on rheological test data, and the needle displacement model was fitted to a nine-order function with time based on real-time displacement test data. The results show that jet performance is related to the diameter of the nozzle outlet and the cone angle of the nozzle, and the impacts of the flow channel structure were confirmed. The approach of numerical simulation is confirmed by the testing results of droplet volume. It will provide a reliable simulation platform for mechanical collision-based jet dispensing and a theoretical basis for micro jet valve design and improvement.

  5. Does anti-malarial drug knowledge predict anti-malarial dispensing practice in drug outlets? A survey of medicine retailers in western Kenya

    Directory of Open Access Journals (Sweden)

    Rusk Andria

    2012-08-01

    Full Text Available Abstract Background Malaria is a major cause of morbidity and mortality in Kenya, where it is the fifth leading cause of death in both children and adults. Effectively managing malaria is dependent upon appropriate treatment. In Kenya, between 17 to 83 percent of febrile individuals first seek treatment for febrile illness over the counter from medicine retailers. Understanding medicine retailer knowledge and behaviour in treating suspected malaria and dispensing anti-malarials is crucial. Methods To investigate medicine retailer knowledge about anti-malarials and their dispensing practices, a survey was conducted of all retail drug outlets that sell anti-malarial medications and serve residents of the Webuye Health and Demographic Surveillance Site in the Bungoma East District of western Kenya. Results Most of the medicine retailers surveyed (65% were able to identify artemether-lumefantrine (AL as the Kenyan Ministry of Health recommended first-line anti-malarial therapy for uncomplicated malaria. Retailers who correctly identified this treatment were also more likely to recommend AL to adult and paediatric customers. However, the proportion of medicine retailers who recommend the correct treatment is disappointingly low. Only 48% would recommend AL to adults, and 37% would recommend it to children. It was discovered that customer demand has an influence on retailer behaviour. Retailer training and education were found to be correlated with anti-malarial drug knowledge, which in turn is correlated with dispensing practices. Medicine retailer behaviour, including patient referral practice and dispensing practices, are also correlated with knowledge of the first-line anti-malarial medication. The Kenya Ministry of Health guidelines were found to influence retailer drug stocking and dispensing behaviours. Conclusion Most medicine retailers could identify the recommended first-line treatment for uncomplicated malaria, but the percentage that could

  6. Automated selection of beam orientations and segmented intensity-modulated radiotherapy (IMRT) for treatment of oesophagus tumors

    International Nuclear Information System (INIS)

    Woudstra, Evert; Heijmen, Ben J.M.; Storchi, Pascal R.M.

    2005-01-01

    Background and purpose: For some treatment sites, there is evidence in the literature that five to nine equiangular input beam directions are enough for generating IMRT plans. For oesophagus cancer, there is a report showing that going from four to nine beams may even result in lower quality plans. In this paper, our previously published algorithm for automated beam angle selection (Cycle) has been extended to include segmented IMRT. For oesophagus cancer patients, we have investigated whether automated orientation selection from a large number of equiangular input beam directions (up to thirty-six) for IMRT optimisation can result in improved lung sparing. Materials and methods: CT-data from five oesophagus patients treated recently in our institute were used for this study. For a prescribed mean PTV dose of 55 Gy, Cycle was used in an iterative procedure to minimise the mean lung dose under the following hard constraints: standard deviation for PTV dose inhomogeneity 2% (1,1 Gy), maximum spinal cord dose 45 Gy. Conformal radiotherapy (CFRT) and IMRT plans for a standard four field oesophagus beam configuration were compared with IMRT plans generated by automated selection from nine or thirty-six equiangular input beam orientations. Comparisons were also made with dose distributions generated with our commercial treatment planning system (TPS), and with observations in the literature. Results: Using Cycle, automated orientation selection from nine or thirty-six input beam directions resulted in improved lung sparing compared to the four field set-ups. Compared to selection from nine input orientations, selection from thirty-six directions did always result in lower mean lung doses, sometimes with even fewer non-zero weight beams. On average only seven beams with a non-zero weight were enough for obtaining the lowest mean lung dose, yielding clinically feasible plans even in case of thirty-six input directions for the optimisation process. With our commercial TPS

  7. Extent of dispensing prescription-only medications without a prescription in community drug retail outlets in Addis Ababa, Ethiopia: a simulated-patient study

    Directory of Open Access Journals (Sweden)

    Erku DA

    2016-07-01

    Full Text Available Daniel Asfaw Erku,1 Abebe Basazn Mekuria,2 Abdrrahman Shemsu Surur,1 Begashaw Melaku Gebresillassie3 1Department of Pharmaceutical Chemistry, 2Department of Pharmacology, 3Department of Clinical Pharmacy, School of Pharmacy, University of Gondar, Gondar, Ethiopia Purpose: This study was aimed at assessing the extent of dispensing prescription-only medications without a prescription in community drug retail outlets (CDROs of Addis Ababa, Ethiopia.Methods: A descriptive cross-sectional observational study design was used to sample 31 pharmacies, 25 drug stores, and two rural drug vendors from August 11, 2015, to October 21, 2015, through a simple random sampling method. A simulated-patient method of visit was implemented to collect data. Requests of six tracer prescription-only medicines (amoxicillin + clavulanic acid capsule, amitriptyline, captopril, glibenclamide [also known as glyburide], omeprazole capsule, and sildenafil citrate and upper respiratory tract infection were selected as the simulated clinical scenario.Results: Amoxicillin–clavulanic acid capsule was dispensed when requested in 87.93% of the dispensaries. All of the CDROs dispensed omeprazole upon request. Sildenafil citrate (Viagra was in stock in 96.55% of the CDROs, all of which issued the requested number of tablets without asking why or for whom the drug was needed. Amitriptyline, captopril, and glibenclamide (glyburide were dispensed in 84.48%, 89.65%, and 87.93% of CDROs upon the provision of an empty container. Antibiotics were obtained from 75.86% of CDROs for presentation of upper respiratory tract infection symptoms. Among the dispensed antibiotics, the most common was amoxicillin (93.18%, followed by amoxicillin–clavulanic acid capsule (72.72%, and azithromycin (50%. Only 4.5% of the dispensaries asked about drug allergies, and 15.9% of the CDROs informed the simulated patient about the possible side effects of the drugs.Conclusion: This study revealed a very high

  8. Towards an automated TLD system that meets international requirements

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.; Vanamo, V.

    1988-01-01

    The new recently introduced fully automated TLD system developed by Alnor OY on the basis of the Riso prototype, is intended to meet draft IEC/ISO proposals and ANSI requirements. Part of the system is a personal dosemeter badge and an environmental dosemeter package following ICRU recommendations. The overall system consists of a software-controlled automated reader, a programable irradiator/calibrator, a computer, and dosemeters for environmental, whole body, extremity and clinical applications. The personal TLD badge that contains four TLD pellets is designed to agree with ICRU H p (10) and H s (0.07) quantities for determining dose equivalent. The badge can accommodate a large variety of the most commonly used solid TL dosemeter products. A special effort was put into the evaluation of skin dose by considering the use of graphite-mixed hot-sintered LiF pellets. The TLD system is described and results from a performance test that comprised measurements of photon energy response, angular dependence, and reproducibility are presented

  9. Relative accuracy and availability of an Irish National Database of dispensed medication as a source of medication history information: observational study and retrospective record analysis.

    LENUS (Irish Health Repository)

    Grimes, T

    2013-01-27

    WHAT IS KNOWN AND OBJECTIVE: The medication reconciliation process begins by identifying which medicines a patient used before presentation to hospital. This is time-consuming, labour intensive and may involve interruption of clinicians. We sought to identify the availability and accuracy of data held in a national dispensing database, relative to other sources of medication history information. METHODS: For patients admitted to two acute hospitals in Ireland, a Gold Standard Pre-Admission Medication List (GSPAML) was identified and corroborated with the patient or carer. The GSPAML was compared for accuracy and availability to PAMLs from other sources, including the Health Service Executive Primary Care Reimbursement Scheme (HSE-PCRS) dispensing database. RESULTS: Some 1111 medication were assessed for 97 patients, who were median age 74 years (range 18-92 years), median four co-morbidities (range 1-9), used median 10 medications (range 3-25) and half (52%) were male. The HSE-PCRS PAML was the most accurate source compared to lists provided by the general practitioner, community pharmacist or cited in previous hospital documentation: the list agreed for 74% of the medications the patients actually used, representing complete agreement for all medications in 17% of patients. It was equally contemporaneous to other sources, but was less reliable for male than female patients, those using increasing numbers of medications and those using one or more item that was not reimbursable by the HSE. WHAT IS NEW AND CONCLUSION: The HSE-PCRS database is a relatively accurate, available and contemporaneous source of medication history information and could support acute hospital medication reconciliation.

  10. A real-time automated quality control of rain gauge data based on multiple sensors

    Science.gov (United States)

    qi, Y.; Zhang, J.

    2013-12-01

    Precipitation is one of the most important meteorological and hydrological variables. Automated rain gauge networks provide direct measurements of precipitation and have been used for numerous applications such as generating regional and national precipitation maps, calibrating remote sensing data, and validating hydrological and meteorological model predictions. Automated gauge observations are prone to a variety of error sources (instrument malfunction, transmission errors, format changes), and require careful quality controls (QC). Many previous gauge QC techniques were based on neighborhood checks within the gauge network itself and the effectiveness is dependent on gauge densities and precipitation regimes. The current study takes advantage of the multi-sensor data sources in the National Mosaic and Multi-Sensor QPE (NMQ/Q2) system and developes an automated gauge QC scheme based the consistency of radar hourly QPEs and gauge observations. Error characteristics of radar and gauge as a function of the radar sampling geometry, precipitation regimes, and the freezing level height are considered. The new scheme was evaluated by comparing an NMQ national gauge-based precipitation product with independent manual gauge observations. Twelve heavy rainfall events from different seasons and areas of the United States are selected for the evaluation, and the results show that the new NMQ product with QC'ed gauges has a more physically spatial distribution than the old product. And the new product agrees much better statistically with the independent gauges.

  11. How complete is the information on preadmission psychotropic medications in inpatients with dementia? A comparison of hospital medical records with dispensing data.

    Science.gov (United States)

    Pisa, Federica Edith; Palese, Francesca; Romanese, Federico; Barbone, Fabio; Logroscino, Giancarlo; Riedel, Oliver

    2018-06-05

    Reliable information on preadmission medications is essential for inpatients with dementia, but its quality has hardly been evaluated. We assessed the completeness of information and factors associated with incomplete recording. We compared preadmission medications recorded in hospital electronic medical records (EMRs) with community-pharmacy dispensations in hospitalizations with discharge code for dementia at the University Hospital of Udine, Italy, 2012-2014. We calculated: (a) prevalence of omissions (dispensed medication not recorded in EMRs), additions (medication recorded in EMRs not dispensed), and discrepancies (any omission or addition); (b) multivariable logistic regression odds ratio, with 95% confidence interval (95% CI), of ≥1 omission. Among 2,777 hospitalizations, 86.1% had ≥1 discrepancy for any medication (Kappa 0.10) and 33.4% for psychotropics. When psychotropics were recorded in EMR, antipsychotics were added in 71.9% (antidepressants: 29.2%, antidementia agents: 48.2%); when dispensed, antipsychotics were omitted in 54.4% (antidepressants: 52.7%, antidementia agents: 41.5%). Omissions were 92% and twice more likely in patients taking 5 to 9 and ≥10 medications (vs. 0 to 4), 17% in patients with psychiatric disturbances (vs. none), and 41% with emergency admission (vs. planned). Psychotropics, commonly used in dementia, were often incompletely recorded. To enhance information completeness, both EMRs and dispensations should be used. Copyright © 2018 John Wiley & Sons, Ltd.

  12. Robotic and nuclear safety for an automated/teleoperated glove box system

    International Nuclear Information System (INIS)

    Domning, E.E.; McMahon, T.T.; Sievers, R.H.

    1991-09-01

    Lawrence Livermore National Laboratory (LLNL) is developing a fully automated system to handle the processing of special nuclear materials (SNM). This work is performed in response to the new goals at the Department of Energy (DOE) for hazardous waste minimization and radiation dose reduction. This fully automated system, called the automated test bed (ATB), consists of an IBM gantry robot and automated processing equipment sealed within a glove box. While the ATB is a cold system, we are designing it as a prototype of the future hot system. We recognized that identification and application of safety requirements early in the design phase will lead to timely installation and approval of the hot system. This paper identifies these safety issues as well as the general safety requirements necessary for the safe operation of the ATB. 4 refs., 2 figs

  13. Low-dose abdominal computed tomography for detection of urinary stone disease - Impact of additional spectral shaping of the X-ray beam on image quality and dose parameters.

    Science.gov (United States)

    Dewes, Patricia; Frellesen, Claudia; Scholtz, Jan-Erik; Fischer, Sebastian; Vogl, Thomas J; Bauer, Ralf W; Schulz, Boris

    2016-06-01

    To evaluate a novel tin filter-based abdominal CT protocol for urolithiasis in terms of image quality and CT dose parameters. 130 consecutive patients with suspected urolithiasis underwent non-enhanced CT with three different protocols: 48 patients (group 1) were examined at tin-filtered 150kV (150kV Sn) on a third-generation dual-source-CT, 33 patients were examined with automated kV-selection (110-140kV) based on the scout view on the same CT-device (group 2), and 49 patients were examined on a second-generation dual-source-CT (group 3) with automated kV-selection (100-140kV). Automated exposure control was active in all groups. Image quality was subjectively evaluated on a 5-point-likert-scale by two radiologists and interobserver agreement as well as signal-to-noise-ratio (SNR) was calculated. Dose-length-product (DLP) and volume CT dose index (CTDIvol) were compared. Image quality was rated in favour for the tin filter protocol with excellent interobserver agreement (ICC=0.86-0.91) and the difference reached statistical significance (pcomputed tomography for urinary stone disease. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Automated processing of X-ray images in medicine

    International Nuclear Information System (INIS)

    Babij, Ya.S.; B'yalyuk, Ya.O.; Yanovich, I.A.; Lysenko, A.V.

    1991-01-01

    Theoretical and practical achievements in application of computing technology means for processing of X-ray images in medicine were generalized. The scheme of the main directions and tasks of processing of X-ray images was given and analyzed. The principal problems appeared in automated processing of X-ray images were distinguished. It is shown that for interpretation of X-ray images it is expedient to introduce a notion of relative operating characteristic (ROC) of a roentgenologist. Every point on ROC curve determines the individual criteria of roentgenologist to put a positive diagnosis for definite situation

  15. PMD: designing a portable medicine dispenser for persons suffering from Alzheimer’s disease

    NARCIS (Netherlands)

    de Beer, Roel C.J.M.; Keijers, R.; Shahid, S.; Al Mahmud, A.; Mubin, O.

    2010-01-01

    In this paper we present the user-centred design of a medicine dispenser for persons suffering from Alzheimer’s disease. The prototype was evaluated in two phases with two caregivers and two Alzheimer’s patients. Caregivers evaluated the device positively. The Alzheimer’s patients faced usability

  16. VLSI Implementation of Hybrid Wave-Pipelined 2D DWT Using Lifting Scheme

    Directory of Open Access Journals (Sweden)

    G. Seetharaman

    2008-01-01

    Full Text Available A novel approach is proposed in this paper for the implementation of 2D DWT using hybrid wave-pipelining (WP. A digital circuit may be operated at a higher frequency by using either pipelining or WP. Pipelining requires additional registers and it results in more area, power dissipation and clock routing complexity. Wave-pipelining does not have any of these disadvantages but requires complex trial and error procedure for tuning the clock period and clock skew between input and output registers. In this paper, a hybrid scheme is proposed to get the benefits of both pipelining and WP techniques. In this paper, two automation schemes are proposed for the implementation of 2D DWT using hybrid WP on both Xilinx, San Jose, CA, USA and Altera FPGAs. In the first scheme, Built-in self-test (BIST approach is used to choose the clock skew and clock period for I/O registers between the wave-pipelined blocks. In the second approach, an on-chip soft-core processor is used to choose the clock skew and clock period. The results for the hybrid WP are compared with nonpipelined and pipelined approaches. From the implementation results, the hybrid WP scheme requires the same area but faster than the nonpipelined scheme by a factor of 1.25–1.39. The pipelined scheme is faster than the hybrid scheme by a factor of 1.15–1.39 at the cost of an increase in the number of registers by a factor of 1.78–2.73, increase in the number of LEs by a factor of 1.11–1.32 and it increases the clock routing complexity.

  17. ALARA implementation in 131I therapeutic capsule production facility

    International Nuclear Information System (INIS)

    Kumawat, Lalit; Swaminathan, N.; Sudheer, T.S.; Sachdev, S.S.; Arora, S.S.; Vairalkar, K.G.

    2005-01-01

    Sodium iodide 131 I solution had been invariably administered to patients for both diagnosis and therapy of thyrotoxicosis. The undue exposure to non-target organs has been over come by introducing NaI ( 131 I) in a gelatin capsule. BRIT has set up experimental facility for the preparation and the production volume has augmented into four fold due to increase in demand and the same facility is being used to cater the need. However, the adequately shielded facility (fume hood) used for (manual) dispensing activity in capsules, capsules and product vial capping, transfer of the vials into lead pots and activity measurement of each vial has resulted in significant increase in the personnel exposure. The sources had been identified and efforts were made to reduce the exposure in these operations. An annular shield was introduced around the dispenser, resulted in the reduction of radiation field at wrist level by a factor of three. Introduction of shielded automated dispenser and usage of longer tools for transfer and capping of vials has effected in two times reduction of collective wrist dose. Currently, the relocated capping station two meters away from the source certainly will bring down further exposure. (author)

  18. Automated detection of analyzable metaphase chromosome cells depicted on scanned digital microscopic images

    Science.gov (United States)

    Qiu, Yuchen; Wang, Xingwei; Chen, Xiaodong; Li, Yuhua; Liu, Hong; Li, Shibo; Zheng, Bin

    2010-02-01

    Visually searching for analyzable metaphase chromosome cells under microscopes is quite time-consuming and difficult. To improve detection efficiency, consistency, and diagnostic accuracy, an automated microscopic image scanning system was developed and tested to directly acquire digital images with sufficient spatial resolution for clinical diagnosis. A computer-aided detection (CAD) scheme was also developed and integrated into the image scanning system to search for and detect the regions of interest (ROI) that contain analyzable metaphase chromosome cells in the large volume of scanned images acquired from one specimen. Thus, the cytogeneticists only need to observe and interpret the limited number of ROIs. In this study, the high-resolution microscopic image scanning and CAD performance was investigated and evaluated using nine sets of images scanned from either bone marrow (three) or blood (six) specimens for diagnosis of leukemia. The automated CAD-selection results were compared with the visual selection. In the experiment, the cytogeneticists first visually searched for the analyzable metaphase chromosome cells from specimens under microscopes. The specimens were also automated scanned and followed by applying the CAD scheme to detect and save ROIs containing analyzable cells while deleting the others. The automated selected ROIs were then examined by a panel of three cytogeneticists. From the scanned images, CAD selected more analyzable cells than initially visual examinations of the cytogeneticists in both blood and bone marrow specimens. In general, CAD had higher performance in analyzing blood specimens. Even in three bone marrow specimens, CAD selected 50, 22, 9 ROIs, respectively. Except matching with the initially visual selection of 9, 7, and 5 analyzable cells in these three specimens, the cytogeneticists also selected 41, 15 and 4 new analyzable cells, which were missed in initially visual searching. This experiment showed the feasibility of

  19. SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C; Xing, L; Fahimian, B [Stanford University, Stanford, CA (United States)

    2016-06-15

    Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic

  20. First UHF Implementation of the Incremental Scheme for Open-Shell Systems.

    Science.gov (United States)

    Anacker, Tony; Tew, David P; Friedrich, Joachim

    2016-01-12

    The incremental scheme makes it possible to compute CCSD(T) correlation energies to high accuracy for large systems. We present the first extension of this fully automated black-box approach to open-shell systems using an Unrestricted Hartree-Fock (UHF) wave function, extending the efficient domain-specific basis set approach to handle open-shell references. We test our approach on a set of organic and metal organic structures and molecular clusters and demonstrate standard deviations from canonical CCSD(T) values of only 1.35 kJ/mol using a triple ζ basis set. We find that the incremental scheme is significantly more cost-effective than the canonical implementation even for relatively small systems and that the ease of parallelization makes it possible to perform high-level calculations on large systems in a few hours on inexpensive computers. We show that the approximations that make our approach widely applicable are significantly smaller than both the basis set incompleteness error and the intrinsic error of the CCSD(T) method, and we further demonstrate that incremental energies can be reliably used in extrapolation schemes to obtain near complete basis set limit CCSD(T) reaction energies for large systems.

  1. An Efficient and Practical Smart Card Based Anonymity Preserving User Authentication Scheme for TMIS using Elliptic Curve Cryptography.

    Science.gov (United States)

    Amin, Ruhul; Islam, S K Hafizul; Biswas, G P; Khan, Muhammad Khurram; Kumar, Neeraj

    2015-11-01

    In the last few years, numerous remote user authentication and session key agreement schemes have been put forwarded for Telecare Medical Information System, where the patient and medical server exchange medical information using Internet. We have found that most of the schemes are not usable for practical applications due to known security weaknesses. It is also worth to note that unrestricted number of patients login to the single medical server across the globe. Therefore, the computation and maintenance overhead would be high and the server may fail to provide services. In this article, we have designed a medical system architecture and a standard mutual authentication scheme for single medical server, where the patient can securely exchange medical data with the doctor(s) via trusted central medical server over any insecure network. We then explored the security of the scheme with its resilience to attacks. Moreover, we formally validated the proposed scheme through the simulation using Automated Validation of Internet Security Schemes and Applications software whose outcomes confirm that the scheme is protected against active and passive attacks. The performance comparison demonstrated that the proposed scheme has lower communication cost than the existing schemes in literature. In addition, the computation cost of the proposed scheme is nearly equal to the exiting schemes. The proposed scheme not only efficient in terms of different security attacks, but it also provides an efficient login, mutual authentication, session key agreement and verification and password update phases along with password recovery.

  2. High-dose-rate intracavitary brachytherapy (HDR-IC) in treatment of cervical carcinoma: 5-year results and implication of increased low-grade rectal complication on initiation of an HDR-IC fractionation scheme

    International Nuclear Information System (INIS)

    Wang Chongjong; Wan Leung, Stephen; Chen Huichun; Sun Limin; Fang Fumin; Changchien Chanchao; Huang Engyen; Wu Jiaming; Chen Chuhnchih

    1997-01-01

    Purpose: To report the treatment results and rectal/bladder complications of cervical carcinoma radically treated with high-dose-rate intracavitary brachytherapy (HDR-IC). The current policy of using three-fraction scheme was examined. Methods and Materials: Between November 1987 and August 1990, 173 patients with cervical carcinoma were treated with curative-intent radiation therapy. Whole pelvic irradiation was administered with 10-MV X ray. Dose to the central cervix was 40-44 Gy in 20-22 fractions, following by pelvic wall boost 6-14 Gy in three to seven fractions with central shielding. 60 Co sources were used for HDR-IC, and 7.2 Gy was given to Point A for three applications, 1-2 weeks apart. Duration of follow-up was 5-7.8 years. Results: Twenty-eight patients (16%) developed central-regional recurrences. Overall 5-year actuarial pelvic control rate was 83%. By stage, 5-year actuarial pelvic control rates were 94%, 87%, and 72% for Stages IB + IIA, IIB + IIIA, and IIIB + IVA, respectively. Thirty-one patients (18%) developed distant metastasis. Overall 5-year actuarial survival rate was 58%. By stage, 5-year actuarial survival rates were 79%, 59%, and 41% for Stages IB + IIA, IIB + IIIA, and IIIB + IVA, respectively. Sixty-six (38%) and 19 patients (11%) developed rectal and bladder complications, respectively. For rectal complication, the overall actuarial rate was 38% at 5 years. By grade, 5-year actuarial rectal complication rates were 24%, 15%, 4%, and 3% for Grades 1-4, respectively. Overall prevalence of rectal complications was 37% and 14% at 2 and 5 years, respectively. Prevalence of low-grade rectal complication (Grades 1 and 2) was dominant at 2 years (30%), but declined to 8% at 5 years. Prevalence of high-grade, severe rectal complication (Grades 3 and 4) remained steady at 2 and 5 years (7% and 6%, respectively). Five-year actuarial bladder complication was 9%. Five-year prevalence of bladder complication was 2%. Conclusion: Using a three

  3. An automated multi-scale network-based scheme for detection and location of seismic sources

    Science.gov (United States)

    Poiata, N.; Aden-Antoniow, F.; Satriano, C.; Bernard, P.; Vilotte, J. P.; Obara, K.

    2017-12-01

    We present a recently developed method - BackTrackBB (Poiata et al. 2016) - allowing to image energy radiation from different seismic sources (e.g., earthquakes, LFEs, tremors) in different tectonic environments using continuous seismic records. The method exploits multi-scale frequency-selective coherence in the wave field, recorded by regional seismic networks or local arrays. The detection and location scheme is based on space-time reconstruction of the seismic sources through an imaging function built from the sum of station-pair time-delay likelihood functions, projected onto theoretical 3D time-delay grids. This imaging function is interpreted as the location likelihood of the seismic source. A signal pre-processing step constructs a multi-band statistical representation of the non stationary signal, i.e. time series, by means of higher-order statistics or energy envelope characteristic functions. Such signal-processing is designed to detect in time signal transients - of different scales and a priori unknown predominant frequency - potentially associated with a variety of sources (e.g., earthquakes, LFE, tremors), and to improve the performance and the robustness of the detection-and-location location step. The initial detection-location, based on a single phase analysis with the P- or S-phase only, can then be improved recursively in a station selection scheme. This scheme - exploiting the 3-component records - makes use of P- and S-phase characteristic functions, extracted after a polarization analysis of the event waveforms, and combines the single phase imaging functions with the S-P differential imaging functions. The performance of the method is demonstrated here in different tectonic environments: (1) analysis of the one year long precursory phase of 2014 Iquique earthquake in Chile; (2) detection and location of tectonic tremor sources and low-frequency earthquakes during the multiple episodes of tectonic tremor activity in southwestern Japan.

  4. Automated and observer based light field indicator edge evaluation in diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Bottaro, Marcio; Nagy, Balazs Vince; Soares, Fernanda Cristina Salvador; Rosendo, Danilo Cabral

    2017-01-01

    Introduction: To analyze edge detection and optical contrast calculation of light field-indicators used in X-ray via automated- and observer-based methods, and comparison with current standard approaches, which do not give exact definition for light field edge determination. Methods: Automated light sensor array was used to measure the penumbra zone of the edge in the standard X-ray equipment, while trained and naive human observers were asked to mark the light field edge according to their own determination. Different interpretations of the contrast were then calculated and compared. Results: In contrast to automated measurements of edge definition and detection, measurements by human observers showed large inter-observer variation independent of their training with X-ray equipment. Different contrast calculations considering the different edge definitions gave very different contrast values. Conclusion: As the main conclusion, we propose a more exact edge definition of the X-ray light field, corresponding well to the average human observer's edge determination. The new edge definition method with automated systems would reduce human variability in edge determination. Such errors could potentially affect the approval of X-ray equipment, and also increase the radiation dose. The automated measurement based on human observers’ edge definition and the corresponding contrast calculation may lead to a more precise light field calibration, which enables reduced irradiation doses on radiology patients. (author)

  5. Automated and observer based light field indicator edge evaluation in diagnostic X-ray equipment

    Directory of Open Access Journals (Sweden)

    Márcio Bottaro

    Full Text Available Abstract Introduction To analyze edge detection and optical contrast calculation of light field-indicators used in X-ray via automated- and observer-based methods, and comparison with current standard approaches, which do not give exact definition for light field edge determination. Methods Automated light sensor array was used to measure the penumbra zone of the edge in the standard X-ray equipment, while trained and naïve human observers were asked to mark the light field edge according to their own determination. Different interpretations of the contrast were then calculated and compared. Results In contrast to automated measurements of edge definition and detection, measurements by human observers showed large inter-observer variation independent of their training with X-ray equipment. Different contrast calculations considering the different edge definitions gave very different contrast values. Conclusion As the main conclusion, we propose a more exact edge definition of the X-ray light field, corresponding well to the average human observer’s edge determination. The new edge definition method with automated systems would reduce human variability in edge determination. Such errors could potentially affect the approval of X-ray equipment, and also increase the radiation dose. The automated measurement based on human observers’ edge definition and the corresponding contrast calculation may lead to a more precise light field calibration, which enables reduced irradiation doses on radiology patients.

  6. Scoring of radiation-induced micronuclei in cytokinesis-blocked human lymphocytes by automated image analysis

    International Nuclear Information System (INIS)

    Verhaegen, F.; Seuntjens, J.; Thierens, H.

    1994-01-01

    The micronucleus assay in human lymphocytes is, at present, frequently used to assess chromosomal damage caused by ionizing radiation or mutagens. Manual scoring of micronuclei (MN) by trained personnel is very time-consuming, tiring work, and the results depend on subjective interpretation of scoring criteria. More objective scoring can be accomplished only if the test can be automated. Furthermore, an automated system allows scoring of large numbers of cells, thereby increasing the statistical significance of the results. This is of special importance for screening programs for low doses of chromosome-damaging agents. In this paper, the first results of our effort to automate the micronucleus assay with an image-analysis system are represented. The method we used is described in detail, and the results are compared to those of other groups. Our system is able to detect 88% of the binucleated lymphocytes on the slides. The procedure consists of a fully automated localization of binucleated cells and counting of the MN within these cells, followed by a simple and fast manual operation in which the false positives are removed. Preliminary measurements for blood samples irradiated with a dose of 1 Gy X-rays indicate that the automated system can find 89% ± 12% of the micronuclei within the binucleated cells compared to a manual screening. 18 refs., 8 figs., 1 tab

  7. Automated and observer based light field indicator edge evaluation in diagnostic X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio; Nagy, Balazs Vince; Soares, Fernanda Cristina Salvador; Rosendo, Danilo Cabral, E-mail: marcio@iee.usp.br [Universidade de Sao Paulo (USP), SP (Brazil); Optics and Engineering Informatics, Budapest University of Technology and Economics, Budapest (Hungary)

    2017-04-15

    Introduction: To analyze edge detection and optical contrast calculation of light field-indicators used in X-ray via automated- and observer-based methods, and comparison with current standard approaches, which do not give exact definition for light field edge determination. Methods: Automated light sensor array was used to measure the penumbra zone of the edge in the standard X-ray equipment, while trained and naive human observers were asked to mark the light field edge according to their own determination. Different interpretations of the contrast were then calculated and compared. Results: In contrast to automated measurements of edge definition and detection, measurements by human observers showed large inter-observer variation independent of their training with X-ray equipment. Different contrast calculations considering the different edge definitions gave very different contrast values. Conclusion: As the main conclusion, we propose a more exact edge definition of the X-ray light field, corresponding well to the average human observer's edge determination. The new edge definition method with automated systems would reduce human variability in edge determination. Such errors could potentially affect the approval of X-ray equipment, and also increase the radiation dose. The automated measurement based on human observers’ edge definition and the corresponding contrast calculation may lead to a more precise light field calibration, which enables reduced irradiation doses on radiology patients. (author)

  8. Analysis of liquid medication dose errors made by patients and caregivers using alternative measuring devices.

    Science.gov (United States)

    Ryu, Gyeong Suk; Lee, Yu Jeung

    2012-01-01

    Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices. To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy. Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended. Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4

  9. SU-E-P-49: Evaluation of Image Quality and Radiation Dose of Various Unenhanced Head CT Protocols

    International Nuclear Information System (INIS)

    Chen, L; Khan, M; Alapati, K; Hsieh, M; Barry, K

    2015-01-01

    Purpose: To evaluate the diagnostic value of various unenhanced head CT protocols and predicate acceptable radiation dose level for head CT exam. Methods: Our retrospective analysis included 3 groups, 20 patients per group, who underwent clinical routine unenhanced adult head CT examination. All exams were performed axially with 120 kVp. Three protocols, 380 mAs without iterative reconstruction and automAs, 340 mAs with iterative reconstruction without automAs, 340 mAs with iterative reconstruction and automAs, were applied on each group patients respectively. The images were reconstructed with H30, J30 for brain window and H60, J70 for bone window. Images acquired with three protocols were randomized and blindly reviewed by three radiologists. A 5 point scale was used to rate each exam The percentage of exam score above 3 and average scores of each protocol were calculated for each reviewer and tissue types. Results: For protocols without automAs, the average scores of bone window with iterative reconstruction were higher than those without iterative reconstruction for each reviewer although the radiation dose was 10 percentage lower. 100 percentage exams were scored 3 or higher and the average scores were above 4 for both brain and bone reconstructions. The CTDIvols are 64.4 and 57.8 mGy of 380 and 340 mAs, respectively. With automAs, the radiation dose varied with head size, resulting in 47.5 mGy average CTDIvol between 39.5 and 56.5 mGy. 93 and 98 percentage exams were scored great than 3 for brain and bone windows, respectively. The diagnostic confidence level and image quality of exams with AutomAs were less than those without AutomAs for each reviewer. Conclusion: According to these results, the mAs was reduced to 300 with automAs OFF for head CT exam. The radiation dose was 20 percentage lower than the original protocol and the CTDIvol was reduced to 51.2 mGy

  10. Automating the production of high-purity zirconium from waste products in industrial furnaces SKB-5025 and apparatuses TS-40M

    International Nuclear Information System (INIS)

    Lavrikov, S.A.; Kotsar', M.L.; Lapidus, A.O.; Akhtonov, S.G.; Aleksandrov, A.V.; Ogorodnikov, L.V.; Chernyshev, A.A.; Kopysov, N.V.

    2014-01-01

    A disadvantage of iodide refining of zirconium in industrial furnaces in the processing of waste products production in JSC CMP is the low direct yield of the metal in iodide rods and large energy consumption of the process. The aim of this work is to optimize the process by means of automated control. The paper deals with the creation of a test unit to automate the iodide refining of zirconium in JSC CMP. The main features of the unit, the hardware and software of the automated unit and the results of its work during the operation are described. A scheme for the automation of 10 furnaces SKB-5025 by optimizing the total cost of computing equipment and for software improvements was proposed and implemented in 2012

  11. Validating a proxy for disease progression in metastatic cancer patients using prescribing and dispensing data.

    Science.gov (United States)

    Joshi, Vikram; Adelstein, Barbara-Ann; Schaffer, Andrea; Srasuebkul, Preeyaporn; Dobbins, Timothy; Pearson, Sallie-Anne

    2017-10-01

    Routine data collections are used increasingly to examine outcomes of real-world cancer drug use. These datasets lack clinical details about important endpoints such as disease progression. To validate a proxy for disease progression in metastatic cancer patients using prescribing and dispensing claims. We used data from a cohort study of patients undergoing chemotherapy who provided informed consent to the collection of cancer-treatment data from medical records and linkage to pharmaceutical claims. We derived proxy decision rules based on changes to drug treatment in prescription histories (n = 36 patients) and validated the proxy in prescribing data (n = 62 patients). We adapted the decision rules and validated the proxy in dispensing data (n = 109). Our gold standard was disease progression ascertained in patient medical records. Individual progression episodes were the unit of analysis for sensitivity and Positive Predictive Value (PPV) calculations and specificity and Negative Predictive Value (NPV) were calculated at the patient level. The sensitivity of our proxy in prescribing data was 74.3% (95% Confidence Interval (CI), 55.6-86.6%) and PPV 61.2% (95% CI, 45.0-75.3%); specificity and NPV were 87.8% (95% CI, 73.8-95.9%) and 100% (95% CI, 90.3-100%), respectively. In dispensing data, the sensitivity of our proxy was 64% (95% CI, 55.0-77.0%) and PPV 56.0% (95% CI, 43.0-69.0%); specificity and NPV were 81% (95% CI, 70.05-89.0%) and 91.0% (95% CI, 82.0-97.0%), respectively. Our proxy overestimated episodes of disease progression. The proxy's performance is likely to improve if the date of prescribing is used instead of date of dispensing in claims data and by incorporating medical service claims (such as imaging prior to drug changes) in the algorithm. Our proxy is not sufficiently robust for use in real world comparative effectiveness research for cancer medicines. © 2016 John Wiley & Sons Australia, Ltd.

  12. Prototype of a Questionnaire and Quiz System for Supporting Increase of Health Awareness During Wait Time in Dispensing Pharmacy

    Science.gov (United States)

    Toda, Takeshi; Chen, Poa-Min; Ozaki, Shinya; Ideguchi, Naoko; Miyaki, Tomoko; Nanbu, Keiko; Ikeda, Keiko

    For quit-smoking clinic and its campaign, there was a need for pharmacists to investigate pediatric patient's parent consciousness to tobacco harm utilizing wait time in a pediatric dispensing pharmacy. In this research, we developed the questionnaire and quiz total system using the tablet for user interface, in which people can easily answer the questionnaire/quiz and quickly see the total results on the spot in order to enhance their consciousness to the tobacco harm. The system also provides their tobacco dependence level based on the questionnaire results and some advice for their health and dietary habits due to the tobacco dependence level. From a field trial with one hundred four examinees in the pediatric dispensing pharmacy, the user interface was useful compared to conventional questionnaire form. The system could enhance their consciousness to tobacco harm and make their beneficial use of waiting time in dispensing pharmacy. Some interesting suggestions for improvement and new services were also obtained.

  13. Altering user' acceptance of automation through prior automation exposure.

    Science.gov (United States)

    Bekier, Marek; Molesworth, Brett R C

    2017-06-01

    Air navigation service providers worldwide see increased use of automation as one solution to overcome the capacity constraints imbedded in the present air traffic management (ATM) system. However, increased use of automation within any system is dependent on user acceptance. The present research sought to determine if the point at which an individual is no longer willing to accept or cooperate with automation can be manipulated. Forty participants underwent training on a computer-based air traffic control programme, followed by two ATM exercises (order counterbalanced), one with and one without the aid of automation. Results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation ('tipping point') decreased; suggesting it is indeed possible to alter automation acceptance. Practitioner Summary: This paper investigates whether the point at which a user of automation rejects automation (i.e. 'tipping point') is constant or can be manipulated. The results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation decreased; suggesting it is possible to alter automation acceptance.

  14. Increasing Access to Subsidized Artemisinin-based Combination Therapy through Accredited Drug Dispensing Outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Gabra Michael

    2011-06-01

    Full Text Available Abstract Background In Tanzania, many people seek malaria treatment from retail drug sellers. The National Malaria Control Program identified the accredited drug dispensing outlet (ADDO program as a private sector mechanism to supplement the distribution of subsidized artemisinin-based combination therapies (ACTs from public facilities and increase access to the first-line antimalarial in rural and underserved areas. The ADDO program strengthens private sector pharmaceutical services by improving regulatory and supervisory support, dispenser training, and record keeping practices. Methods The government's pilot program made subsidized ACTs available through ADDOs in 10 districts in the Morogoro and Ruvuma regions, covering about 2.9 million people. The program established a supply of subsidized ACTs, created a price system with a cost recovery plan, developed a plan to distribute the subsidized products to the ADDOs, trained dispensers, and strengthened the adverse drug reactions reporting system. As part of the evaluation, 448 ADDO dispensers brought their records to central locations for analysis, representing nearly 70% of ADDOs operating in the two regions. ADDO drug register data were available from July 2007-June 2008 for Morogoro and from July 2007-September 2008 for Ruvuma. This intervention was implemented from 2007-2008. Results During the pilot, over 300,000 people received treatment for malaria at the 448 ADDOs. The percentage of ADDOs that dispensed at least one course of ACT rose from 26.2% during July-September 2007 to 72.6% during April-June 2008. The number of malaria patients treated with ACTs gradually increased after the start of the pilot, while the use of non-ACT antimalarials declined; ACTs went from 3% of all antimalarials sold in July 2007 to 26% in June 2008. District-specific data showed substantial variation among the districts in ACT uptake through ADDOs, ranging from ACTs representing 10% of all antimalarial sales

  15. Radon-222 related influence on ambient gamma dose.

    Science.gov (United States)

    Melintescu, A; Chambers, S D; Crawford, J; Williams, A G; Zorila, B; Galeriu, D

    2018-04-03

    Ambient gamma dose, radon, and rainfall have been monitored in southern Bucharest, Romania, from 2010 to 2016. The seasonal cycle of background ambient gamma dose peaked between July and October (100-105 nSv h -1 ), with minimum values in February (75-80 nSv h -1 ), the time of maximum snow cover. Based on 10 m a.g.l. radon concentrations, the ambient gamma dose increased by around 1 nSv h -1 for every 5 Bq m -3 increase in radon. Radon variability attributable to diurnal changes in atmospheric mixing contributed less than 15 nSv h -1 to the overall variability in ambient gamma dose, a factor of 4 more than synoptic timescale changes in air mass fetch. By contrast, precipitation-related enhancements of the ambient gamma dose were 15-80 nSv h -1 . To facilitate routine analysis, and account in part for occasional equipment failure, an automated method for identifying precipitation spikes in the ambient gamma dose was developed. Lastly, a simple model for predicting rainfall-related enhancement of the ambient gamma dose is tested against rainfall observations from events of contrasting duration and intensity. Results are also compared with those from previously published models of simple and complex formulation. Generally, the model performed very well. When simulations underestimated observations the absolute difference was typically less than the natural variability in ambient gamma dose arising from atmospheric mixing influences. Consequently, combined use of the automated event detection method and the simple model of this study could enable the ambient gamma dose "attention limit" (which indicates a potential radiological emergency) to be reduced from 200 to 400% above background to 25-50%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Development, implementation and outcome analysis of semi-automated alerts for metformin dose adjustment in hospitalized patients with renal impairment.

    Science.gov (United States)

    Niedrig, David; Krattinger, Regina; Jödicke, Annika; Gött, Carmen; Bucklar, Guido; Russmann, Stefan

    2016-10-01

    Overdosing of the oral antidiabetic metformin in impaired renal function is an important contributory cause to life-threatening lactic acidosis. The presented project aimed to quantify and prevent this avoidable medication error in clinical practice. We developed and implemented an algorithm into a hospital's clinical information system that prospectively identifies metformin prescriptions if the estimated glomerular filtration rate is below 60 mL/min. Resulting real-time electronic alerts are sent to clinical pharmacologists and pharmacists, who validate cases in electronic medical records and contact prescribing physicians with recommendations if necessary. The screening algorithm has been used in routine clinical practice for 3 years and generated 2145 automated alerts (about 2 per day). Validated expert recommendations regarding metformin therapy, i.e., dose reduction or stop, were issued for 381 patients (about 3 per week). Follow-up was available for 257 cases, and prescribers' compliance with recommendations was 79%. Furthermore, during 3 years, we identified eight local cases of lactic acidosis associated with metformin therapy in renal impairment that could not be prevented, e.g., because metformin overdosing had occurred before hospitalization. Automated sensitive screening followed by specific expert evaluation and personal recommendations can prevent metformin overdosing in renal impairment with high efficiency and efficacy. Repeated cases of metformin-associated lactic acidosis in renal impairment underline the clinical relevance of this medication error. Our locally developed and customized alert system is a successful proof of concept for a proactive clinical drug safety program that is now expanded to other clinically and economically relevant medication errors. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Accurate, consistent, and fast droplet splitting and dispensing in electrowetting on dielectric digital microfluidics

    Science.gov (United States)

    Nikapitiya, N. Y. Jagath B.; Nahar, Mun Mun; Moon, Hyejin

    2017-12-01

    This letter reports two novel electrode design considerations to satisfy two very important aspects of EWOD operation—(1) Highly consistent volume of generated droplets and (2) Highly improved accuracy in the generated droplet volume. Considering the design principles investigated two novel designs were proposed; L-junction electrode design to offer high throughput droplet generation and Y-junction electrode design to split a droplet very fast while maintaining equal volume of each part. Devices of novel designs were fabricated and tested, and the results are compared with those of conventional approach. It is demonstrated that inaccuracy and inconsistency of droplet volume dispensed in the device with novel electrode designs are as low as 0.17 and 0.10%, respectively, while those of conventional approach are 25 and 0.76%, respectively. The dispensing frequency is enhanced from 4 to 9 Hz by using the novel design.

  18. Reliability Constrained Priority Load Shedding for Aerospace Power System Automation

    Science.gov (United States)

    Momoh, James A.; Zhu, Jizhong; Kaddah, Sahar S.; Dolce, James L. (Technical Monitor)

    2000-01-01

    The need for improving load shedding on board the space station is one of the goals of aerospace power system automation. To accelerate the optimum load-shedding functions, several constraints must be involved. These constraints include congestion margin determined by weighted probability contingency, component/system reliability index, generation rescheduling. The impact of different faults and indices for computing reliability were defined before optimization. The optimum load schedule is done based on priority, value and location of loads. An optimization strategy capable of handling discrete decision making, such as Everett optimization, is proposed. We extended Everett method to handle expected congestion margin and reliability index as constraints. To make it effective for real time load dispatch process, a rule-based scheme is presented in the optimization method. It assists in selecting which feeder load to be shed, the location of the load, the value, priority of the load and cost benefit analysis of the load profile is included in the scheme. The scheme is tested using a benchmark NASA system consisting of generators, loads and network.

  19. Adaptive response induced by low doses of ionizing radiation in human lymphocytes

    International Nuclear Information System (INIS)

    Frati, Diego Libkind; Bunge, Maria M.

    2001-01-01

    The term adaptive response (AR) applies to the phenomenon of protection or enhanced repair induced by a small dose of a mutagenic agent. In order to determine the existence of AR in human lymphocytes for two different irradiation schemes, microcultures of blood from 4 donors were irradiated. Samples were exposed 24 hours (hr) after phytohemagglutinin stimulation to an adapting dose of 0,01 Gy and to a challenging dose of 1,5 Gy either 6 or 24 hr later (irradiation scheme 24+30 or 24+48, respectively). Gamma radiation from a 2,5 MeV Linac was used in all experiments. A cytogenetic analysis of unstable chromosome aberrations was applied as the endpoint. High inter-individual variability was found for the first irradiation scheme: one expressed AR, two did not and the last showed an apparent synergistic response. For the second irradiation scheme, low mitotic indices (MI) were found, suggesting a G2 arrest. When a series of harvesting times were applied for the last donor, normal MI were obtained only harvesting after 58 hr. An AR was found when harvesting at 72 hr but not at 58 hr. (author)

  20. ANA IIF Automation: Moving towards Harmonization? Results of a Multicenter Study

    Directory of Open Access Journals (Sweden)

    Stefanie Van den Bremt

    2017-01-01

    Full Text Available Background. Our study aimed to investigate whether the introduction of automated anti-nuclear antibody (ANA indirect immunofluorescence (IIF analysis decreases the interlaboratory variability of ANA titer results. Method. Three serum samples were sent to 10 laboratories using the QUANTA-Lyser® in combination with the NOVA View®. Each laboratory performed the ANA IIF analysis 10x in 1 run and 1x in 10 different runs and determined the endpoint titer by dilution. One of the three samples had been sent in 2012, before the era of ANA IIF automation, by the Belgian National External Quality Assessment (EQA Scheme. Harmonization was evaluated in terms of variability in fluorescence intensity (LIU and ANA IIF titer. Results. The evaluation of the intra- and interrun LIU variability revealed a larger variability for 2 laboratories, due to preanalytical and analytical problems. Reanalysis of the EQA sample resulted in a lower titer variability. Diluted endpoint titers were similar to the estimated single well titer and the overall median titer as reported by the EQA in 2012. Conclusion. The introduction of automated microscopic analysis allows more harmonized ANA IIF reporting, provided that this totally automated process is controlled by a thorough quality assurance program, covering the total ANA IIF process.

  1. Complacency and Automation Bias in the Use of Imperfect Automation.

    Science.gov (United States)

    Wickens, Christopher D; Clegg, Benjamin A; Vieane, Alex Z; Sebok, Angelia L

    2015-08-01

    We examine the effects of two different kinds of decision-aiding automation errors on human-automation interaction (HAI), occurring at the first failure following repeated exposure to correctly functioning automation. The two errors are incorrect advice, triggering the automation bias, and missing advice, reflecting complacency. Contrasts between analogous automation errors in alerting systems, rather than decision aiding, have revealed that alerting false alarms are more problematic to HAI than alerting misses are. Prior research in decision aiding, although contrasting the two aiding errors (incorrect vs. missing), has confounded error expectancy. Participants performed an environmental process control simulation with and without decision aiding. For those with the aid, automation dependence was created through several trials of perfect aiding performance, and an unexpected automation error was then imposed in which automation was either gone (one group) or wrong (a second group). A control group received no automation support. The correct aid supported faster and more accurate diagnosis and lower workload. The aid failure degraded all three variables, but "automation wrong" had a much greater effect on accuracy, reflecting the automation bias, than did "automation gone," reflecting the impact of complacency. Some complacency was manifested for automation gone, by a longer latency and more modest reduction in accuracy. Automation wrong, creating the automation bias, appears to be a more problematic form of automation error than automation gone, reflecting complacency. Decision-aiding automation should indicate its lower degree of confidence in uncertain environments to avoid the automation bias. © 2015, Human Factors and Ergonomics Society.

  2. On Converting Secret Sharing Scheme to Visual Secret Sharing Scheme

    Directory of Open Access Journals (Sweden)

    Wang Daoshun

    2010-01-01

    Full Text Available Abstract Traditional Secret Sharing (SS schemes reconstruct secret exactly the same as the original one but involve complex computation. Visual Secret Sharing (VSS schemes decode the secret without computation, but each share is m times as big as the original and the quality of the reconstructed secret image is reduced. Probabilistic visual secret sharing (Prob.VSS schemes for a binary image use only one subpixel to share the secret image; however the probability of white pixels in a white area is higher than that in a black area in the reconstructed secret image. SS schemes, VSS schemes, and Prob. VSS schemes have various construction methods and advantages. This paper first presents an approach to convert (transform a -SS scheme to a -VSS scheme for greyscale images. The generation of the shadow images (shares is based on Boolean XOR operation. The secret image can be reconstructed directly by performing Boolean OR operation, as in most conventional VSS schemes. Its pixel expansion is significantly smaller than that of VSS schemes. The quality of the reconstructed images, measured by average contrast, is the same as VSS schemes. Then a novel matrix-concatenation approach is used to extend the greyscale -SS scheme to a more general case of greyscale -VSS scheme.

  3. Robotic weeding and automated weed measurements

    DEFF Research Database (Denmark)

    Christensen, S.; Søgaard, H.T.; Jørgensen, R.N.

    2003-01-01

    The goal of decreasing herbicide usage has so far focused on reducing the herbicide dosage or replacing chemical weed control by hoeing and harrowing. The conventional weed control strategy is to apply the same dose of herbicide or the same intensity of hoeing and harrowing in the whole field. Th...... the state-of-the-art of automated weed measurement methods and the research projects concerning autonomous platform and information system for crop and weed monitoring and robotic weeding....

  4. Multi-pulsed intense electron beam emission from velvet, carbon fibers, carbon nano-tubes and dispenser cathodes

    International Nuclear Information System (INIS)

    Xia Liansheng; Yang Anmin; Chen Yi; Zhang Huang; Liu Xingguang; Li Jin; Jiang Xiaoguo; Zhang Kaizhi; Shi Jinshui; Deng Jianjun; Zhang Linwen

    2010-01-01

    The experimental results of studies of four kinds of cathode emitting intense electron beams are demonstrated under multi-pulsed mode based on an experimental setup including two multi-pulse high voltage sources. The tested cathodes include velvet, carbon fibers, carbon nano-tubes (CNTs) and dispenser cathodes. The results indicate that all four are able to emit multi-pulsed beams. For velvet, carbon fiber and CNTs, the electron induced cathode plasma emission may be the main process and this means that there are differences in beam parameters from pulse to pulse. For dispenser cathodes tested in the experiment, although there is a little difference from pulse to pulse for some reason, thermal-electric field emission may be the main process. (authors)

  5. An Optimization Scheme for Water Pump Control in Smart Fish Farm with Efficient Energy Consumption

    Directory of Open Access Journals (Sweden)

    Israr Ullah

    2018-06-01

    Full Text Available Healthy fish production requires intensive care and ensuring stable and healthy production environment inside the farm tank is a challenging task. An Internet of Things (IoT based automated system is highly desirable that can continuously monitor the fish tanks with optimal resources utilization. Significant cost reduction can be achieved if farm equipment and water pumps are operated only when required using optimization schemes. In this paper, we present a general system design for smart fish farms. We have developed an optimization scheme for water pump control to maintain desired water level in fish tank with efficient energy consumption through appropriate selection of pumping flow rate and tank filling level. Proposed optimization scheme attempts to achieve a trade-off between pumping duration and flow rate through selection of optimized water level. Kalman filter algorithm is applied to remove error in sensor readings. We observed through simulation results that optimization scheme achieve significant reduction in energy consumption as compared to the two alternate schemes, i.e., pumping with maximum and minimum flow rates. Proposed system can help in collecting the data about the farm for long-term analysis and better decision making in future for efficient resource utilization and overall profit maximization.

  6. A novel, microcomputer-based process control scheme for radiochemistry autosynthesizers

    International Nuclear Information System (INIS)

    Feliu, A.L.

    1989-01-01

    With the continuing development of positron emission tomography, increasing emphasis is being given to the design of reliable autosynthesizers to supply routinely-used radiopharmaceuticals. In order to reduce the time required to automate the synthesis of new radiotracers, a software scheme is proposed which includes: a generic control program supporting a standard set of components, end-user customization of the video display, mouse-driven remote control of individual components (components are presented on screen as icons), and a batch language for completely automating synthetic operations. This strategy is illustrated in a chemist-friendly microcomputer softward package running under MS-DOS which exploits the features and full flexibility of the CTI/Siemens Chemical Process Control Unit. To facilitate system expansion, the program, written in Microsoft QuickBASIC, contains generic executive-level code with calls to component-specific GOSUBs, and is designed to accommodate operation or hardware modifications in response to improvements in synthetic art without a rewrite. Two user-generated configuration files detail synthesis-specific parameters, providing a customized interface

  7. Radiologist and angiographic procedures. Absorbed radiation dose

    International Nuclear Information System (INIS)

    Tryhus, M.; Mettler, F.A. Jr.; Kelsey, C.

    1987-01-01

    The radiation dose absorbed by the angiographer during angiographic procedures is of vital importance to the radiologist. Nevertheless, most articles on the subject are incomplete, and few measure gonadal dose. In this study, three TLDs were used for each of the following sites: radiologist's eyes, thyroid, gonads with and without shielding apron, and hands. The average dose during carotid angiograms was 2.6, 4.1, 0.4, 4.7, and 7.1 mrads to the eyes, thyroid, gonads with and without .5 mm of lead shielding, and hands, respectively. Average dose during abdominal and peripheral vascular angiographic procedures was 5.2, 7.5, 1.2, 8.5, and 39.9 mrads to the eyes, thyroid, gonads with and without shielding, and hands, respectively. A literature review demonstrates a significant reduction in radiation dose to the angiographer after the advent of automated injectors. Our measured doses for carotid angiography are compatible with contemporary reported values. There was poor correlation with fluoroscopy time and measured dose to the angiographer

  8. A unified inversion scheme to process multifrequency measurements of various dispersive electromagnetic properties

    Science.gov (United States)

    Han, Y.; Misra, S.

    2018-04-01

    Multi-frequency measurement of a dispersive electromagnetic (EM) property, such as electrical conductivity, dielectric permittivity, or magnetic permeability, is commonly analyzed for purposes of material characterization. Such an analysis requires inversion of the multi-frequency measurement based on a specific relaxation model, such as Cole-Cole model or Pelton's model. We develop a unified inversion scheme that can be coupled to various type of relaxation models to independently process multi-frequency measurement of varied EM properties for purposes of improved EM-based geomaterial characterization. The proposed inversion scheme is firstly tested in few synthetic cases in which different relaxation models are coupled into the inversion scheme and then applied to multi-frequency complex conductivity, complex resistivity, complex permittivity, and complex impedance measurements. The method estimates up to seven relaxation-model parameters exhibiting convergence and accuracy for random initializations of the relaxation-model parameters within up to 3-orders of magnitude variation around the true parameter values. The proposed inversion method implements a bounded Levenberg algorithm with tuning initial values of damping parameter and its iterative adjustment factor, which are fixed in all the cases shown in this paper and irrespective of the type of measured EM property and the type of relaxation model. Notably, jump-out step and jump-back-in step are implemented as automated methods in the inversion scheme to prevent the inversion from getting trapped around local minima and to honor physical bounds of model parameters. The proposed inversion scheme can be easily used to process various types of EM measurements without major changes to the inversion scheme.

  9. Randomized crossover study evaluating the effect of a hand sanitizer dispenser on the frequency of hand hygiene among anesthesiology staff in the operating room.

    Science.gov (United States)

    Munoz-Price, L Silvia; Patel, Zalak; Banks, Shawn; Arheart, Kristopher; Eber, Scott; Lubarsky, David A; Birnbach, David J

    2014-06-01

    Forty anesthesia providers were evaluated with and without hand sanitizer dispensers present on the anesthesia machine. Having a dispenser increased the frequency of hand hygiene only from 0.5 to 0.8 events per hour (P = .01). Other concomitant interventions are needed to further increase hand hygiene frequency among anesthesia providers.

  10. Assessment of automated disease detection in diabetic retinopathy screening using two-field photography.

    Science.gov (United States)

    Goatman, Keith; Charnley, Amanda; Webster, Laura; Nussey, Stephen

    2011-01-01

    To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of both eyes were acquired and independently graded according to the English national grading scheme. Where discrepancies were found between the automated result and original manual grade, internal and external arbitration was used to determine the final study grades. Two versions of the software were used: one that detected microaneurysms alone, and one that detected blot haemorrhages and exudates in addition to microaneurysms. Results for each version were calculated once using both fields and once using the macula-centred field alone. Of the 8,271 episodes, 346 (4.2%) were considered unassessable. Referable disease was detected in 587 episodes (7.1%). The sensitivity of the automated system for detecting unassessable images ranged from 97.4% to 99.1% depending on configuration. The sensitivity of the automated system for referable episodes ranged from 98.3% to 99.3%. All the episodes that included proliferative or pre-proliferative retinopathy were detected by the automated system regardless of configuration (192/192, 95% confidence interval 98.0% to 100%). If implemented as the first step in grading, the automated system would have reduced the manual grading effort by between 2,183 and 3,147 patient episodes (26.4% to 38.1%). Automated grading can safely reduce the workload of manual grading using two field, mydriatic photography in a routine screening service.

  11. Single-dose radiotherapy for painful bone metastases

    International Nuclear Information System (INIS)

    Kal, H.B.

    1999-01-01

    Background: External beam radiotherapy is frequently applied for palliative treatment of painful bone lesions with a variety of fractionation schemes. There is a continuous interest to administer only 1 or a few dose fractions for inducing pain relief. Methods: A review of the literature was made with the aim to determine whether a treatment can be deduced that is simple and effective. The linear-quadratic (L-Q) concept was applied to compare reported therapy schemes which each other for the iso-effect pain relief. Results: Single-dose and fractionated radiotherapy resulted in partial or complete pain relief in about 80% of the patients. Complete responses have been observed in about 43% of the patients. For patients responding to treatment, the duration of pain relief is at least 3 to 4 months with reported duration of up to 1 year or even longer. Conclusion: Based on this review of literature data concerning randomized trials a treatment with a single dose of 8 Gy is effective for inducing pain relief. (orig.) [de

  12. A secure user anonymity-preserving three-factor remote user authentication scheme for the telecare medicine information systems.

    Science.gov (United States)

    Das, Ashok Kumar

    2015-03-01

    Recent advanced technology enables the telecare medicine information system (TMIS) for the patients to gain the health monitoring facility at home and also to access medical services over the Internet of mobile networks. Several remote user authentication schemes have been proposed in the literature for TMIS. However, most of them are either insecure against various known attacks or they are inefficient. Recently, Tan proposed an efficient user anonymity preserving three-factor authentication scheme for TMIS. In this paper, we show that though Tan's scheme is efficient, it has several security drawbacks such as (1) it fails to provide proper authentication during the login phase, (2) it fails to provide correct updation of password and biometric of a user during the password and biometric update phase, and (3) it fails to protect against replay attack. In addition, Tan's scheme lacks the formal security analysis and verification. Later, Arshad and Nikooghadam also pointed out some security flaws in Tan's scheme and then presented an improvement on Tan's s scheme. However, we show that Arshad and Nikooghadam's scheme is still insecure against the privileged-insider attack through the stolen smart-card attack, and it also lacks the formal security analysis and verification. In order to withstand those security loopholes found in both Tan's scheme, and Arshad and Nikooghadam's scheme, we aim to propose an effective and more secure three-factor remote user authentication scheme for TMIS. Our scheme provides the user anonymity property. Through the rigorous informal and formal security analysis using random oracle models and the widely-accepted AVISPA (Automated Validation of Internet Security Protocols and Applications) tool, we show that our scheme is secure against various known attacks, including the replay and man-in-the-middle attacks. Furthermore, our scheme is also efficient as compared to other related schemes.

  13. Adherence to drug label recommendations for avoiding drug interactions causing statin-induced myopathy--a nationwide register study.

    Directory of Open Access Journals (Sweden)

    Jennifer Settergren

    Full Text Available To investigate the extent to which clinicians avoid well-established drug-drug interactions that cause statin-induced myopathy. We hypothesised that clinicians would avoid combining erythromycin or verapamil/diltiazem respectively with atorvastatin or simvastatin. In patients with statin-fibrate combination therapy, we hypothesised that gemfibrozil was avoided to the preference of bezafibrate or fenofibrate. When combined with verapamil/diltiazem or fibrates, we hypothesized that the dispensed doses of atorvastatin/simvastatin would be decreased.Cross-sectional analysis of nationwide dispensing data. Odds ratios of interacting erythromycin, verapamil/diltiazem versus respective prevalence of comparator drugs doxycycline, amlodipine/felodipine in patients co-dispensed interacting statins simvastatin/atorvastatin versus patients unexposed (pravastatin/fluvastatin/rosuvastatin was calculated. For fibrates, OR of gemfibrozil versus fenofibrate/bezafibrate in patients co-dispensed any statin was assessed.OR of interacting erythromycin versus comparator doxycycline did not differ between patients on interacting and comparator statins either in patients dispensed high or low statin doses (adjusted OR 0.87; 95% CI 0.60-1.25 and 0.92; 95% CI 0.69-1.23. Interacting statins were less common among patients dispensed verapamil/diltiazem as compared to patients on amlodipine/felodipine (OR high dose 0.62; CI 0.56-0.68 and low dose 0.63; CI 0.58-0.68. Patients on any statin were to a lesser extent dispensed gemfibrozil compared to patients not dispensed a statin (OR high dose 0.65; CI 0.55-0.76 and low dose 0.70; CI 0.63-0.78. Mean DDD (SD for any statin was substantially higher in patients co-dispensed gemfibrozil 178 (149 compared to patients on statin monotherapy 127 (93, (p<0.001.Prescribers may to some extent avoid co-prescription of statins with calcium blockers and fibrates with an increased risk of myopathy. We found no evidence for avoiding co

  14. [Food and beverages available in automatic food dispensers in health care facilities of the Portugal North Health Region].

    Science.gov (United States)

    Rodrigues, Filipa Gomes; Ramos, Elisabete; Freitas, Mário; Neto, Maria

    2010-01-01

    Patients and health staff frequently need to stay in health care facilities for quite a long time. Therefore, it's necessary to create the conditions that allow the ingestion of food during those periods, namely through the existence of automatic food dispensers. However, the available food and beverages might not always be compatible with a healthy diet. The aim of this work was to evaluate if the food and beverages available in automatic food dispensers in public Ambulatory Care Facilities (ACF) and Hospitals of the Portugal North Health Region were contributing to a healthy diet, during the year of 2007. A questionnaire was elaborated and sent to the Coordinators of the Health Sub-Regions and to the Hospital Administrators. The questionnaire requested information about the existence of automatic food dispensers in the several departments of each health care facility, as well as which food and beverages were available and most sold. Afterwards, the pre-processing of the results involved the classification of the food and beverages in three categories: recommended, sometimes recommended and not recommended. The questionnaire reply ratio was 71% in ACF and 83% in Hospitals. Automatic food dispensers were available in all the Hospitals and 86.5% of ACF. It wasn't possible to acquire food in 37% of the health facility departments. These departments were all located in ACF. The more frequently available beverages in departments with automatic food dispensers were coffee, still water, tea, juices and nectars and soft drinks. Still water, coffee, yogurt, juices and nectars and soft drinks were reported as the most sold. The more frequently avaliable food items were chocolate, recommended cookies, not recommended cakes, recommended sandwiches and sometimes recommended croissants. The food items reported as being the most sold were recommended sandwiches, chocolate, recommended cookies, sometimes recommended croissants and not recommended cookies. The beverages in the

  15. Calculation of committed dose equivalent from intake of tritiated water

    International Nuclear Information System (INIS)

    Law, D.V.

    1978-08-01

    A new computerized method of calculating the committed dose equivalent from the intake of tritiated water at Harwell is described in this report. The computer program has been designed to deal with a variety of intake patterns and urine sampling schemes, as well as to produce committed dose equivalents corresponding to any periods for which individual monitoring for external radiation is undertaken. Details of retrospective doses are added semi-automatically to the Radiation Dose Records and committed dose equivalents are retained on a separate file. (author)

  16. A model for drug dispensing service based on the care process in the Brazilian health system

    Directory of Open Access Journals (Sweden)

    Luciano Soares

    2013-03-01

    Full Text Available Access to medication emphasizes the availability of the product at the expense of providing a service. The goal of this paper is to propose a theoretical model for a drug dispensing service, beginning with a reflection on the current realities of the Unified Health System and drug dispensation in Brazil. A conceptual analytical research made by a methodological course called disciplined imagination was mainly the approach applied to develop the model. The drug dispensing service is part of the care process, which considers access as an attribute; reception, connection and accountability, management, and clinical pharmaceutical aspects as components; and the rational use of drugs as the purpose. The proposed model addresses access to the dispensing service and demands a reorientation of routines, instruments, and practices.O acesso a medicamentos enfatiza a disponibilidade do produto em detrimento da provisão de um serviço. O objetivo deste trabalho é propor um modelo teórico para um serviço de dispensação de medicamentos, iniciando com uma reflexão sobre a realidade atual do Sistema Único de Saúde e a dispensação de medicamentos no Brasil. Uma pesquisa analítica conceitual realizada por meio de um percurso metodológico chamado de imaginação disciplinada constituiu a estratégia principal para o desenvolvimento do modelo. O serviço de dispensação é parte do processo de cuidado, o qual considera o acesso como um atributo; os aspectos acolhimento, vínculo e responsabilização, gestão e clínica farmacêutica como componentes e o uso racional de medicamentos como o propósito. O modelo proposto direciona o acesso para o serviço de dispensação e demanda a reorientação de rotinas, instrumentos e práticas.

  17. Improving the driver-automation interaction: an approach using automation uncertainty.

    Science.gov (United States)

    Beller, Johannes; Heesen, Matthias; Vollrath, Mark

    2013-12-01

    The aim of this study was to evaluate whether communicating automation uncertainty improves the driver-automation interaction. A false system understanding of infallibility may provoke automation misuse and can lead to severe consequences in case of automation failure. The presentation of automation uncertainty may prevent this false system understanding and, as was shown by previous studies, may have numerous benefits. Few studies, however, have clearly shown the potential of communicating uncertainty information in driving. The current study fills this gap. We conducted a driving simulator experiment, varying the presented uncertainty information between participants (no uncertainty information vs. uncertainty information) and the automation reliability (high vs.low) within participants. Participants interacted with a highly automated driving system while engaging in secondary tasks and were required to cooperate with the automation to drive safely. Quantile regressions and multilevel modeling showed that the presentation of uncertainty information increases the time to collision in the case of automation failure. Furthermore, the data indicated improved situation awareness and better knowledge of fallibility for the experimental group. Consequently, the automation with the uncertainty symbol received higher trust ratings and increased acceptance. The presentation of automation uncertaintythrough a symbol improves overall driver-automation cooperation. Most automated systems in driving could benefit from displaying reliability information. This display might improve the acceptance of fallible systems and further enhances driver-automation cooperation.

  18. Automating the expert consensus paradigm for robust lung tissue classification

    Science.gov (United States)

    Rajagopalan, Srinivasan; Karwoski, Ronald A.; Raghunath, Sushravya; Bartholmai, Brian J.; Robb, Richard A.

    2012-03-01

    Clinicians confirm the efficacy of dynamic multidisciplinary interactions in diagnosing Lung disease/wellness from CT scans. However, routine clinical practice cannot readily accomodate such interactions. Current schemes for automating lung tissue classification are based on a single elusive disease differentiating metric; this undermines their reliability in routine diagnosis. We propose a computational workflow that uses a collection (#: 15) of probability density functions (pdf)-based similarity metrics to automatically cluster pattern-specific (#patterns: 5) volumes of interest (#VOI: 976) extracted from the lung CT scans of 14 patients. The resultant clusters are refined for intra-partition compactness and subsequently aggregated into a super cluster using a cluster ensemble technique. The super clusters were validated against the consensus agreement of four clinical experts. The aggregations correlated strongly with expert consensus. By effectively mimicking the expertise of physicians, the proposed workflow could make automation of lung tissue classification a clinical reality.

  19. TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

    International Nuclear Information System (INIS)

    Hardy, A; Bostani, M; McMillan, K; Zankl, M; Cagnon, C; McNitt-Gray, M

    2016-01-01

    Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical

  20. TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, A; Bostani, M [University of California, Los Angeles, Los Angeles, CA (United States); McMillan, K [Mayo Clinic, Rochester, MN (United States); Zankl, M [Helmholtz Zentrum Munchen, Neuherberg (Germany); Cagnon, C [UCLA Medical Center, Los Angeles, CA (United States); McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical

  1. Biologically effective dose distribution based on the linear quadratic model and its clinical relevance

    International Nuclear Information System (INIS)

    Lee, Steve P.; Leu, Min Y.; Smathers, James B.; McBride, William H.; Parker, Robert G.; Withers, H. Rodney

    1995-01-01

    Purpose: Radiotherapy plans based on physical dose distributions do not necessarily entirely reflect the biological effects under various fractionation schemes. Over the past decade, the linear-quadratic (LQ) model has emerged as a convenient tool to quantify biological effects for radiotherapy. In this work, we set out to construct a mechanism to display biologically oriented dose distribution based on the LQ model. Methods and Materials: A computer program that converts a physical dose distribution calculated by a commercially available treatment planning system to a biologically effective dose (BED) distribution has been developed and verified against theoretical calculations. This software accepts a user's input of biological parameters for each structure of interest (linear and quadratic dose-response and repopulation kinetic parameters), as well as treatment scheme factors (number of fractions, fractional dose, and treatment time). It then presents a two-dimensional BED display in conjunction with anatomical structures. Furthermore, to facilitate clinicians' intuitive comparison with conventional fractionation regimen, a conversion of BED to normalized isoeffective dose (NID) is also allowed. Results: Two sample cases serve to illustrate the application of our tool in clinical practice. (a) For an orthogonal wedged pair of x-ray beams treating a maxillary sinus tumor, the biological effect at the ipsilateral mandible can be quantified, thus illustrates the so-called 'double-trouble' effects very well. (b) For a typical four-field, evenly weighted prostate treatment using 10 MV x-rays, physical dosimetry predicts a comparable dose at the femoral necks between an alternate two-fields/day and four-fields/day schups. However, our BED display reveals an approximate 21% higher BED for the two-fields/day scheme. This excessive dose to the femoral necks can be eliminated if the treatment is delivered with a 3:2 (anterio-posterior/posterio-anterior (AP

  2. Large area dispenser cathode applied to high current linac

    International Nuclear Information System (INIS)

    Yang Anmin; China Academy of Engineering Physics, Mianyang; Wu Dengxue; Liu Chenjun; Xia Liansheng; Wang Wendou; Zhang Kaizhi

    2005-01-01

    The paper introduced a dispenser cathode (411 M) which was 55 mm in diameter. A 200 kV long pulsed power generator with 2 μs flattop based on Marx-PEN and system with heat and voltage insulation were built. A 52 A space charge limited current was gained, when the temperature was 1165 degree C and the filament current was 18 A on the cathode and the voltage of the pulse was 75 kV at the cathode test stand. Experimental results show that the current values are consistent with the numerical simulation. The experiment reveals that the deflated gas will influence the cathode emission ability. (authors)

  3. Dicer is dispensable for asymmetric RISC loading in mammals.

    Science.gov (United States)

    Betancur, Juan G; Tomari, Yukihide

    2012-01-01

    In flies, asymmetric loading of small RNA duplexes into Argonaute2-containing RNA-induced silencing complex (Ago2-RISC) requires Dicer-2/R2D2 heterodimer, which acts as a protein sensor for the thermodynamic stabilities of the ends of small RNA duplexes. However, the mechanism of small RNA asymmetry sensing in mammalian RISC assembly remains obscure. Here, we quantitatively examined RISC assembly and target silencing activity in the presence or absence of Dicer in mammals. Our data show that, unlike the well-characterized fly Ago2-RISC assembly pathway, mammalian Dicer is dispensable for asymmetric RISC loading in vivo and in vitro.

  4. Automated detection of masses on whole breast volume ultrasound scanner: false positive reduction using deep convolutional neural network

    Science.gov (United States)

    Hiramatsu, Yuya; Muramatsu, Chisako; Kobayashi, Hironobu; Hara, Takeshi; Fujita, Hiroshi

    2017-03-01

    Breast cancer screening with mammography and ultrasonography is expected to improve sensitivity compared with mammography alone, especially for women with dense breast. An automated breast volume scanner (ABVS) provides the operator-independent whole breast data which facilitate double reading and comparison with past exams, contralateral breast, and multimodality images. However, large volumetric data in screening practice increase radiologists' workload. Therefore, our goal is to develop a computer-aided detection scheme of breast masses in ABVS data for assisting radiologists' diagnosis and comparison with mammographic findings. In this study, false positive (FP) reduction scheme using deep convolutional neural network (DCNN) was investigated. For training DCNN, true positive and FP samples were obtained from the result of our initial mass detection scheme using the vector convergence filter. Regions of interest including the detected regions were extracted from the multiplanar reconstraction slices. We investigated methods to select effective FP samples for training the DCNN. Based on the free response receiver operating characteristic analysis, simple random sampling from the entire candidates was most effective in this study. Using DCNN, the number of FPs could be reduced by 60%, while retaining 90% of true masses. The result indicates the potential usefulness of DCNN for FP reduction in automated mass detection on ABVS images.

  5. Cost-effectiveness of HPV vaccination regime: comparing twice versus thrice vaccinations dose regime among adolescent girls in Malaysia.

    Science.gov (United States)

    Aljunid, Syed; Maimaiti, Namaitijiang; Nur, Amrizal M; Noor, Mohd Rushdan Md; Wan Puteh, Sharifa Ezat

    2016-01-23

    The HPV vaccine was introduced to Malaysian national immunization programme in 2010. The current implementation age of HPV vaccination in Malaysian is at the age of 13 years school girls, given according to a 3 doses protocol which may complicate implementation and compliance. Aim of the study is to determine the cost-effectiveness of HPV vaccination regime comparing twice versus thrice HPV vaccinations dose regime among adolescent girls in Malaysia. A Markov cohort model reflecting the natural history of HPV infection accounting for oncogenic and low-risk HPV was adapted for 13 year old Malaysian girls cohort (n = 274,050). Transition probabilities, utilities values, epidemiological and cost data were sourced from published literature and local data. Vaccine effectiveness was based on overall efficacy reported from 3-doses clinical trials, with the assumption that the 2-doses is non-inferior to the 3-doses allowing overall efficacy to be inferred from the 3-doses immunogenicity data. Price parity and life-long protection were assumed. The payer perspective was adopted, with appropriate discounting for costs (3 %) and outcomes (3 %). One way sensitivity analysis was conducted. The sensitivity analysis on cost of vaccine, vaccine coverage and discount rate with a 2-doses protocol was performed. The 3-doses and 2-doses regimes showed same number of Cervical Cancers averted (361 cases); QALYs saved at 7,732,266. However, the lifetime protection under the 2-doses regime, showed a significant cost-savings of RM 36, 722,700 compared to the 3-doses scheme. The MOH Malaysia could vaccinate 137,025 more girls in this country using saving 2-doses regime vaccination programme. The model predicted that 2-doses HPV vaccination schemes can avoid additional 180 Cervical Cancers and 63 deaths compare to 3-doses. A 2-doses HPV vaccination scheme may enable Malaysian women to be protected at a lower cost than that achievable under a 3-doses scheme, while avoiding the same number of

  6. The impact of a closed‐loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before‐and‐after study

    Science.gov (United States)

    Franklin, Bryony Dean; O'Grady, Kara; Donyai, Parastou; Jacklin, Ann; Barber, Nick

    2007-01-01

    Objectives To assess the impact of a closed‐loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants Before‐and‐after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention Closed‐loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results Prescribing errors were identified in 3.8% of 2450 medication orders pre‐intervention and 2.0% of 2353 orders afterwards (pMedical staff required 15 s to prescribe a regular inpatient drug pre‐intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre‐intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; χ2 test). Conclusions A closed‐loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication‐related tasks increased. PMID:17693676

  7. Drug dispensing practices at pharmacies in Bengaluru: A cross-sectional study

    OpenAIRE

    R Soumya; Vijayalakshmi Devarashetty; C R Jayanthi; M Sushma

    2016-01-01

    Objectives: Pharmacists are one of the crucial focal points for health care in the community. They have tremendous outreach to the public as pharmacies are often the first-port-of-call. With the increase of ready-to-use drugs, the main health-related activity of a pharmacist today is to assure the quality of dispensing, a key element to promote rational medicine use. Materials and Methods: A cross-sectional study of 200 pharmacies, 100 each in various residential (R) and commercial (C) areas ...

  8. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  9. Automated chemical kinetic modeling via hybrid reactive molecular dynamics and quantum chemistry simulations.

    Science.gov (United States)

    Döntgen, Malte; Schmalz, Felix; Kopp, Wassja A; Kröger, Leif C; Leonhard, Kai

    2018-06-13

    An automated scheme for obtaining chemical kinetic models from scratch using reactive molecular dynamics and quantum chemistry simulations is presented. This methodology combines the phase space sampling of reactive molecular dynamics with the thermochemistry and kinetics prediction capabilities of quantum mechanics. This scheme provides the NASA polynomial and modified Arrhenius equation parameters for all species and reactions that are observed during the simulation and supplies them in the ChemKin format. The ab initio level of theory for predictions is easily exchangeable and the presently used G3MP2 level of theory is found to reliably reproduce hydrogen and methane oxidation thermochemistry and kinetics data. Chemical kinetic models obtained with this approach are ready-to-use for, e.g., ignition delay time simulations, as shown for hydrogen combustion. The presented extension of the ChemTraYzer approach can be used as a basis for methodologically advancing chemical kinetic modeling schemes and as a black-box approach to generate chemical kinetic models.

  10. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  11. PSS431

    Data.gov (United States)

    Department of Veterans Affairs — Returns a list of Unit Dose medications from data in the UNIT DOSE sub-file (#55.06) of the PHARMACY PATIENT file (#55) and dispensed drugs from the DISPENSE DRUG...

  12. Effectance, committed effective dose equivalent and annual limits on intake: what are the changes?

    International Nuclear Information System (INIS)

    Kendall, G.M.; Stather, J.W.; Phipps, A.W.

    1990-01-01

    This paper outlines the concept of effectance, compares committed effectance with the old committed effective dose equivalent and goes on to discuss changes in the annual limits on intakes and the maximum organ doses which would result from an intake of an ALI (Annual Limit of Intake). It is shown that committed effectance is usually, but not always, higher than committed effective dose equivalent. ALIS are usually well below those resulting from the ICRP Publication 30 scheme. However, if the ALI were based only on a limit on effectance it would imply a high dose to specific organs for certain nuclides. In order to control maximum organ doses an explicit limit could be introduced. However, this would destroy some of the attractive features of the new scheme. An alternative would be a slight modification to some of the weighting factors. (author)

  13. A secure and robust password-based remote user authentication scheme using smart cards for the integrated EPR information system.

    Science.gov (United States)

    Das, Ashok Kumar

    2015-03-01

    An integrated EPR (Electronic Patient Record) information system of all the patients provides the medical institutions and the academia with most of the patients' information in details for them to make corrective decisions and clinical decisions in order to maintain and analyze patients' health. In such system, the illegal access must be restricted and the information from theft during transmission over the insecure Internet must be prevented. Lee et al. proposed an efficient password-based remote user authentication scheme using smart card for the integrated EPR information system. Their scheme is very efficient due to usage of one-way hash function and bitwise exclusive-or (XOR) operations. However, in this paper, we show that though their scheme is very efficient, their scheme has three security weaknesses such as (1) it has design flaws in password change phase, (2) it fails to protect privileged insider attack and (3) it lacks the formal security verification. We also find that another recently proposed Wen's scheme has the same security drawbacks as in Lee at al.'s scheme. In order to remedy these security weaknesses found in Lee et al.'s scheme and Wen's scheme, we propose a secure and efficient password-based remote user authentication scheme using smart cards for the integrated EPR information system. We show that our scheme is also efficient as compared to Lee et al.'s scheme and Wen's scheme as our scheme only uses one-way hash function and bitwise exclusive-or (XOR) operations. Through the security analysis, we show that our scheme is secure against possible known attacks. Furthermore, we simulate our scheme for the formal security verification using the widely-accepted AVISPA (Automated Validation of Internet Security Protocols and Applications) tool and show that our scheme is secure against passive and active attacks.

  14. Automation of dimethylation after guanidination labeling chemistry and its compatibility with common buffers and surfactants for mass spectrometry-based shotgun quantitative proteome analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lo, Andy; Tang, Yanan; Chen, Lu; Li, Liang, E-mail: Liang.Li@ualberta.ca

    2013-07-25

    Graphical abstract: -- Highlights: •Dimethylation after guanidination (2MEGA) uses inexpensive reagents for isotopic labeling of peptides. •2MEGA can be optimized and automated for labeling peptides with high efficiency. •2MEGA is compatible with several commonly used cell lysis and protein solubilization reagents. •The automated 2MEGA labeling method can be used to handle a variety of protein samples for relative proteome quantification. -- Abstract: Isotope labeling liquid chromatography–mass spectrometry (LC–MS) is a major analytical platform for quantitative proteome analysis. Incorporation of isotopes used to distinguish samples plays a critical role in the success of this strategy. In this work, we optimized and automated a chemical derivatization protocol (dimethylation after guanidination, 2MEGA) to increase the labeling reproducibility and reduce human intervention. We also evaluated the reagent compatibility of this protocol to handle biological samples in different types of buffers and surfactants. A commercially available liquid handler was used for reagent dispensation to minimize analyst intervention and at least twenty protein digest samples could be prepared in a single run. Different front-end sample preparation methods for protein solubilization (SDS, urea, Rapigest™, and ProteaseMAX™) and two commercially available cell lysis buffers were evaluated for compatibility with the automated protocol. It was found that better than 94% desired labeling could be obtained in all conditions studied except urea, where the rate was reduced to about 92% due to carbamylation on the peptide amines. This work illustrates the automated 2MEGA labeling process can be used to handle a wide range of protein samples containing various reagents that are often encountered in protein sample preparation for quantitative proteome analysis.

  15. The optimal fraction size in high-dose-rate brachytherapy: dependency on tissue repair kinetics and low-dose rate

    International Nuclear Information System (INIS)

    Sminia, Peter; Schneider, Christoph J.; Fowler, Jack F.

    2002-01-01

    Background and Purpose: Indications of the existence of long repair half-times on the order of 2-4 h for late-responding human normal tissues have been obtained from continuous hyperfractionated accelerated radiotherapy (CHART). Recently, these data were used to explain, on the basis of the biologically effective dose (BED), the potential superiority of fractionated high-dose rate (HDR) with large fraction sizes of 5-7 Gy over continuous low-dose rate (LDR) irradiation at 0.5 Gy/h in cervical carcinoma. We investigated the optimal fraction size in HDR brachytherapy and its dependency on treatment choices (overall treatment time, number of HDR fractions, and time interval between fractions) and treatment conditions (reference low-dose rate, tissue repair characteristics). Methods and Materials: Radiobiologic model calculations were performed using the linear-quadratic model for incomplete mono-exponential repair. An irradiation dose of 20 Gy was assumed to be applied either with HDR in 2-12 fractions or continuously with LDR for a range of dose rates. HDR and LDR treatment regimens were compared on the basis of the BED and BED ratio of normal tissue and tumor, assuming repair half-times between 1 h and 4 h. Results: With the assumption that the repair half-time of normal tissue was three times longer than that of the tumor, hypofractionation in HDR relative to LDR could result in relative normal tissue sparing if the optimum fraction size is selected. By dose reduction while keeping the tumor BED constant, absolute normal tissue sparing might therefore be achieved. This optimum HDR fraction size was found to be largely dependent on the LDR dose rate. On the basis of the BED NT/TUM ratio of HDR over LDR, 3 x 6.7 Gy would be the optimal HDR fractionation scheme for replacement of an LDR scheme of 20 Gy in 10-30 h (dose rate 2-0.67 Gy/h), while at a lower dose rate of 0.5 Gy/h, four fractions of 5 Gy would be preferential, still assuming large differences between tumor

  16. Refinement of Foam Backfill Technology for Expedient Airfield Damage Repair; Phase 2: Development of Prototype Foam Dispensing Equipment and Improved Tactics, Techniques and Procedures

    Science.gov (United States)

    2017-12-01

    ER D C TR -1 7- 14 U.S. Air Force Rapid Airfield Damage Repair Modernization Program Refinement of Foam Backfill Technology for...Backfill Technology for Expedient Airfield Damage Repair Phase II: Development of Prototype Foam Dispensing Equipment and Improved Tactics...procedures (TTPs) for rapid airfield damage repair (RADR) using foam backfill technology . Three different prototype foam dispensing systems were

  17. A secure and efficient uniqueness-and-anonymity-preserving remote user authentication scheme for connected health care.

    Science.gov (United States)

    Das, Ashok Kumar; Goswami, Adrijit

    2013-06-01

    Connected health care has several applications including telecare medicine information system, personally controlled health records system, and patient monitoring. In such applications, user authentication can ensure the legality of patients. In user authentication for such applications, only the legal user/patient himself/herself is allowed to access the remote server, and no one can trace him/her according to transmitted data. Chang et al. proposed a uniqueness-and-anonymity-preserving remote user authentication scheme for connected health care (Chang et al., J Med Syst 37:9902, 2013). Their scheme uses the user's personal biometrics along with his/her password with the help of the smart card. The user's biometrics is verified using BioHashing. Their scheme is efficient due to usage of one-way hash function and exclusive-or (XOR) operations. In this paper, we show that though their scheme is very efficient, their scheme has several security weaknesses such as (1) it has design flaws in login and authentication phases, (2) it has design flaws in password change phase, (3) it fails to protect privileged insider attack, (4) it fails to protect the man-in-the middle attack, and (5) it fails to provide proper authentication. In order to remedy these security weaknesses in Chang et al.'s scheme, we propose an improvement of their scheme while retaining the original merit of their scheme. We show that our scheme is efficient as compared to Chang et al.'s scheme. Through the security analysis, we show that our scheme is secure against possible attacks. Further, we simulate our scheme for the formal security verification using the widely-accepted AVISPA (Automated Validation of Internet Security Protocols and Applications) tool to ensure that our scheme is secure against passive and active attacks. In addition, after successful authentication between the user and the server, they establish a secret session key shared between them for future secure communication.

  18. Low-cost automated system for phase-shifting and phase retrieval based on the tunability of a laser diode

    Science.gov (United States)

    Rivera-Ortega, Uriel; Dirckx, Joris

    2016-09-01

    A low-cost and fully automated process for phase-shifting interferometry by continuously changing and turning on-off the input voltage of a laser diode under the scheme of an unbalanced Twyman-Green interferometer setup is presented. The input signal of a laser diode is controlled by a Data Acquisition (NI-DAQ) device which permits to change its wavelength according to its tunability features. The automation and data analysis will be done using LabVIEW in combination with MATLAB. By using Carré algorithm the phase map is obtained. Measurements of visibility and phase-shift to verify the PSI requirements are also shown.

  19. A World Wide Web-based antimicrobial stewardship program improves efficiency, communication, and user satisfaction and reduces cost in a tertiary care pediatric medical center.

    Science.gov (United States)

    Agwu, Allison L; Lee, Carlton K K; Jain, Sanjay K; Murray, Kara L; Topolski, Jason; Miller, Robert E; Townsend, Timothy; Lehmann, Christoph U

    2008-09-15

    Antimicrobial stewardship programs aim to reduce inappropriate hospital antimicrobial use. At the Johns Hopkins Children's Medical and Surgical Center (Baltimore, MD), we implemented a World Wide Web-based antimicrobial restriction program to address problems with the existing restriction program. A user survey identified opportunities for improvement of an existing antimicrobial restriction program and resulted in subsequent design, implementation, and evaluation of a World Wide Web-based antimicrobial restriction program at a 175-bed, tertiary care pediatric teaching hospital. The program provided automated clinical decision support, facilitated approval, and enhanced real-time communication among prescribers, pharmacists, and pediatric infectious diseases fellows. Approval status, duration, and rationale; missing request notifications; and expiring approvals were stored in a database that is accessible via a secure Intranet site. Before and after implementation of the program, user satisfaction, reports of missed and/or delayed doses, antimicrobial dispensing times, and cost were evaluated. After implementation of the program, there was a $370,069 reduction in projected annual cost associated with restricted antimicrobial use and an 11.6% reduction in the number of dispensed doses. User satisfaction increased from 22% to 68% and from 13% to 69% among prescribers and pharmacists, respectively. There were 21% and 32% reductions in the number of prescriber reports of missed and delayed doses, respectively, and there was a 37% reduction in the number of pharmacist reports of delayed approvals; measured dispensing times were unchanged (P = .24). In addition, 40% fewer restricted antimicrobial-related phone calls were noted by the pharmacy. The World Wide Web-based antimicrobial approval program led to improved communication, more-efficient antimicrobial administration, increased user satisfaction, and significant cost savings. Integrated tools, such as this World

  20. Automated system for individual control for admission of staff in the controlled zones of the Kozloduy NPP

    International Nuclear Information System (INIS)

    Avramski, D.; Jordanova, V.

    2008-01-01

    The development of the system leads to the following: automated registering of the staff in the personnel database; real time reading of the personal dosimeters; real time reading of the collective dose; the control over the working people (especially external) concerning the dose limits or restrictions are performed in real time