WorldWideScience

Sample records for autologous mini punch

  1. Paper Punch Tape

    CERN Multimedia

    Physicists coded and recorded their programs through series of holes on punch paper tape or on punched cards. It was popular in the 1970s due to its high throughput speed and low cost, paper tape was one of the original data storage methods for computers. Information was encoded in the distinct pattern of holes punched in the paper; the paper itself was oiled to facilitate being run through the reading mechanism and to prevent tears due to brittleness. Though the paper was cheap, it had low storage capacity (only a few dozen kilobytes per roll) and the machinery involved in punching the holes was quite expensive. Higher capacity alternatives, such as magnetic tape, has get developped.

  2. Treatment of a Refractory Skin Ulcer Using Punch Graft and Autologous Platelet-Rich Plasma

    Directory of Open Access Journals (Sweden)

    Mauro Carducci

    2016-01-01

    Full Text Available Background. Chronic ulceration of the lower legs is a relatively common condition amongst adults: one that causes pain and social distress and results in considerable healthcare and personal costs. The technique of punch grafting offers an alternative approach to the treatment of ulcers of the lower limbs. Objective. Combining platelet-rich plasma and skin graft enhances the efficacy of treating chronic diabetic wounds by enhancing healing rate and decreasing recurrence rate. Platelet-rich plasma could, by stimulating dermal regeneration, increase the take rate after skin grafting or speed up reepithelialization. Methods and Materials. The ulcer was prepared by removing fibrin with a curette and the edges of the ulcer were freshened. The platelet-rich plasma has been infiltrated on the bottom and edges of the ulcer. The punch grafts were placed in 5 mm holes arranged. The ulcer was medicated with hydrogel and a pressure dressing was removed after 8 days. Results. After a few days the patient did not report more pain. Granulation tissue appeared quickly between implants. Most of the grafts were viable in 2-3 weeks. The grafts gradually came together to close the ulcer and were completed in four months.

  3. Computer Data Punch Cards

    CERN Multimedia

    Those card are printed with minimal layout aids for the formatting of FORTRAN programs, plus extra guidelines every ten columns suggesting a generic tabular data layout. A punch card is a piece of stiff paper that can be used to contain digital information represented by the presence or absence of holes in predefined positions. Punched cards were used for specialized unit record machines, organized into semiautomatic data processing systems, used punched cards for data input, output, and storage. Furthermore many new digital computers started to used punched cards.

  4. Very heavy iron-punching concretes

    International Nuclear Information System (INIS)

    Dubois, F.

    1966-01-01

    The present report deals with all the heavy iron-punching concretes, metallic wastes produced by the transformation industry. After a detailed description of the physical properties of metallic aggregates, a classification of heavy mortars is given, into three main categories: steel-shot grouts d = 5,3 - 6; steel-shot grouts mixed with a mineral d = 3,7 - 4,2; injection heavy grouts d = 3,5 - 4. The following chapter describes iron-punching concretes the most used in the atomic industry: iron-punching concretes mixed with cast-iron - iron-punching concretes mixed with magnetite; iron-punching concretes mixed with barite; iron-punching concretes mixed with limonite; iron-punching concretes mixed with boron. The compositions of these concretes are given together with their physical and mechanical characteristics. Numerous diagrams make it possible to find rapidly the proportions of the constituents of these concretes as a function of the required density. Technical advice and specifications are given in an appendix together with a bibliography of these heavy concretes. (author) [fr

  5. Studies of lubricants and punch design in punching of stainless steel

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2004-01-01

    Environmentally hazardous lubricants such as chlorinated paraffin oils are often applied in punching and blanking operations especially involving stainless steel workpiece materials. This is due to the fact that punching and blanking are among the tribologically most difficult forming operations...

  6. Joint punching and frequency effects on practical magnetic characteristics of electrical steels for high-speed machines

    Science.gov (United States)

    Kedous-Lebouc, A.; Messal, O.; Youmssi, A.

    2017-03-01

    Mechanical punching of electrical steels causes a degradation of their magnetic characteristics which can extend several millimeters from the cut edge. So, in the field of industrial applications, particularly that of small electrical machines, the stator core made of rigid and thin teeth would be subject to more losses. Thus, this topic of the effect of punching has to be submitted to further deep characterization and development in order to give some insight into the different mechanisms. In this framework, this paper evaluates the combined effect of punching and frequency on the magnetization curve and iron losses in thin SiFe and CoFe soft magnetic sheets. These alloys are typically suitable for the manufacture of high-speed electrical machines used in on board applications (aircraft power generators, automotive, etc). Two SiFe alloys and a CoFe alloy have been investigated. First, different rectangular samples of variable width (15, 10, 5, 3 mm) have been industrially punched. Then, a dedicated magnetic characterization has been made, using basically a mini-Epstein frame. Measurements have been performed from 50 Hz to 1 kHz and from 0.3 T to near saturation. Both rolling and transverse directions have been considered. Finally, a first attempt to predict the degradation due to the punching is presented. A useful description of the magnetic permeability as a function of B and f is given and the degradation parameters are estimated based on the knowledge of the reference permeability.

  7. Joint punching and frequency effects on practical magnetic characteristics of electrical steels for high-speed machines

    Energy Technology Data Exchange (ETDEWEB)

    Kedous-Lebouc, A. [Univ. Grenoble Alpes, G2Elab, F-38000 Grenoble, France — CNRS, G2Elab, F-38000 Grenoble (France); Messal, O., E-mail: oualid.messal@g2elab.grenoble-inp.fr [Univ. Grenoble Alpes, G2Elab, F-38000 Grenoble, France — CNRS, G2Elab, F-38000 Grenoble (France); Youmssi, A. [Université de N’gaoundéré, BP. 455 N’Gaoundéré (Cameroon)

    2017-03-15

    Mechanical punching of electrical steels causes a degradation of their magnetic characteristics which can extend several millimeters from the cut edge. So, in the field of industrial applications, particularly that of small electrical machines, the stator core made of rigid and thin teeth would be subject to more losses. Thus, this topic of the effect of punching has to be submitted to further deep characterization and development in order to give some insight into the different mechanisms. In this framework, this paper evaluates the combined effect of punching and frequency on the magnetization curve and iron losses in thin SiFe and CoFe soft magnetic sheets. These alloys are typically suitable for the manufacture of high-speed electrical machines used in on board applications (aircraft power generators, automotive, etc). Two SiFe alloys and a CoFe alloy have been investigated. First, different rectangular samples of variable width (15, 10, 5, 3 mm) have been industrially punched. Then, a dedicated magnetic characterization has been made, using basically a mini-Epstein frame. Measurements have been performed from 50 Hz to 1 kHz and from 0.3 T to near saturation. Both rolling and transverse directions have been considered. Finally, a first attempt to predict the degradation due to the punching is presented. A useful description of the magnetic permeability as a function of B and f is given and the degradation parameters are estimated based on the knowledge of the reference permeability.

  8. 21 CFR 882.4750 - Skull punch.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skull punch. 882.4750 Section 882.4750 Food and... NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4750 Skull punch. (a) Identification. A skull punch is a device used to punch holes through a patient's skull to allow fixation of cranioplasty plates or...

  9. Lubricant test for punching and blanking

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2003-01-01

    Punching/blanking is one of the tribologically wise most severe metal forming processes.Insu $cient lubrication leads to heavy pick-up of work piece material on the punch stem,bad tolerances and eventual breakdown of the punch due to excessive backstroke force,especially in case of tribologically...... of alternative lubricants the present paper describes a new lubricant test for punching....

  10. Meniscal shear stress for punching.

    Science.gov (United States)

    Tuijthof, Gabrielle J M; Meulman, Hubert N; Herder, Just L; van Dijk, C Niek

    2009-01-01

    Experimental determination of the shear stress for punching meniscal tissue. Meniscectomy (surgical treatment of a lesion of one of the menisci) is the most frequently performed arthroscopic procedure. The performance of a meniscectomy is not optimal with the currently available instruments. To design new instruments, the punching force of meniscal tissue is an important parameter. Quantitative data are unavailable. The meniscal punching process was simulated by pushing a rod through meniscal tissue at constant speed. Three punching rods were tested: a solid rod of Oslash; 3.00 mm, and two hollow tubes (Oslash; 3.00-2.60 mm) with sharpened cutting edges of 0.15 mm and 0.125 mm thick, respectively. Nineteen menisci acquired from 10 human cadaveric knee joints were punched (30 tests). The force and displacement were recorded from which the maximum shear stress was determined (average added with three times the standard deviation). The maximum shear stress for the solid rod was determined at 10.2 N/mm2. This rod required a significantly lower punch force in comparison with the hollow tube having a 0.15 mm cutting edge (plt;0.01). The maximum shear stress for punching can be applied to design instruments, and virtual reality training environments. This type of experiment is suitable to form a database with material properties of human tissue similar to databases for the manufacturing industry.

  11. The composite of bone marrow concentrate and PRP as an alternative to autologous bone grafting.

    Directory of Open Access Journals (Sweden)

    Mohssen Hakimi

    Full Text Available One possible alternative to the application of autologous bone grafts represents the use of autologous bone marrow concentrate (BMC. The purpose of our study was to evaluate the potency of autologous platelet-rich plasma (PRP in combination with BMC. In 32 mini-pigs a metaphyseal critical-size defect was surgically created at the proximal tibia. The animals were allocated to four treatment groups of eight animals each (1. BMC+CPG group, 2. BMC+CPG+PRP group, 3. autograft group, 4. CPG group. In the BMC+CPG group the defect was filled with autologous BMC in combination with calcium phosphate granules (CPG, whereas in the BMC+CPG+PRP group the defect was filled with the composite of autologous BMC, CPG and autologous PRP. In the autograft group the defect was filled with autologous cancellous graft, whereas in the CPG group the defect was filled with CPG solely. After 6 weeks radiological and histomorphometrical analysis showed significantly more new bone formation in the BMC+CPG+PRP group compared to the BMC+CPG group and the CPG group. There were no significant differences between the BMC+CPG+PRP group and the autograft group. In the PRP platelets were enriched significantly about 4.7-fold compared to native blood. In BMC the count of mononuclear cells increased significantly (3.5-fold compared to the bone marrow aspirate. This study demonstrates that the composite of BMC+CPG+PRP leads to a significantly higher bone regeneration of critical-size defects at the proximal tibia in mini-pigs than the use of BMC+CPG without PRP. Furthermore, within the limits of the present study the composite BMC+CPG+PRP represents a comparable alternative to autologous bone grafting.

  12. Measuring the force of punches using an accelerometric punching bag - Relationship between force of punches and power of jump - An example of application of the modern information technology in sport

    Science.gov (United States)

    Pilewska, Wiesława; Buśko, Krzysztof; Nikolaidis, Pantelis Theodoros

    2017-11-01

    The main aim of the study was to design a new system to measure punching forces in boxers. In addition, the study examined whether there were any relationship between force of punches and power of jump. A total of 9 boxers (age: 17.5±1.2 years, body height: 174.1±8.1 cm, body mass: 73.9±11.8 kg) participated in the study. The punching bag was equipped with acceleration transducers and gyroscopes embedded in a cylinder covered with a layer to absorb shock as well as a set of colour signal diodes. Value of the punching bag's acceleration was used for calculating: strike force; the punching location on the bag; and time of a strike. The relative error of force calculation was 3%; the relative error in acceleration measurement was less than 1%. The maximal straight of rear and lead punching forces were 1702.4±497.8 N and 1262.0±417.7 N in boxers, respectively. Strong correlations were found between the punching force and power of lower limbs developed for the ACMJ, CMJ and SPJ jump. Height of rise of the body mass centre and punching force correlated insignificantly. Based on these findings, it was concluded that the modified punching bag is a good diagnostic tool for combat sports. The measurement of power during the jump may be a good diagnostic test in boxers.

  13. NCDC Punched Card Reference Manuals

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Documentation for using and reading punched cards kept at the National Weather Records Center (NWRC, previous name for NCDC and NCEI). Many of these punched card...

  14. Novel uses of skin biopsy punches in dermatosurgery

    Directory of Open Access Journals (Sweden)

    Deepak S Hurkudli

    2015-01-01

    Full Text Available The skin punch or surgical punch is an instrument which is used almost exclusively by dermatologists. It is a circular hollow blade attached to a pencil-like handle ranging in size from 0.5 to 10 mm. It is available as a disposable, reusable, and automated instrument. The punch can be used as a diagnostic, therapeutic, and cosmetic tool in dermatology. We have used punch as a diagnostic, therapeutic, and cosmetic tool in our dermatosurgery practice in our hospital. Various original research articles, text book publications, and review articles were studied and compiled. Techniques used by various authors and our own experiences with punch have been described. This article aims at providing the novel usefulness of skin biopsy punch in dermatology as the basic punch surgery is quick and easy to learn. Complications such as bleeding and infection are minimal.

  15. Prediction of effects of punch shapes on tableting failure by using a multi-functional single-punch tablet press

    Directory of Open Access Journals (Sweden)

    Takashi Osamura

    2017-09-01

    Full Text Available We previously determined “Tableting properties” by using a multi-functional single-punch tablet press (GTP-1. We proposed plotting “Compactability” on the x-axis against “Manufacturability” on the y-axis to allow visual evaluation of “Tableting properties”. Various types of tableting failure occur in commercial drug production and are influenced by the amount of lubricant used and the shape of the punch. We used the GTP-1 to measure “Tableting properties” with different amounts of lubricant and compared the results with those of tableting on a commercial rotary tableting machine. Tablets compressed with a small amount of lubricant showed bad “Manufacturability”, leading to sticking of powder on punches. We also tested various punch shapes. The GTP-1 correctly predicted the actual tableting results for all punch shapes. With punches that were more likely to cause tableting failure, our system predicted the effects of lubricant quantity in the tablet formulation and the occurrence of sticking in the rotary tableting machine.

  16. Teach yourself visually Mac Mini

    CERN Document Server

    Hart-Davis, Guy

    2012-01-01

    The perfect how-to guide for visual learners Apple?s Mac Mini packs a powerful punch is in a small package, including both HDMI and Thunderbolt ports plus the acclaimed OS X. But if you want to get the very most from all this power and versatility, be sure to get this practical visual guide. With full-color, step-by-step instructions as well as screenshots and illustrations on every page, it clearly shows you how to accomplish tasks rather than burying you in pages of text. Discover helpful visuals and how-tos on the OS, hardware specs, Launchpad, the App Store, multimedia capabilities (such

  17. Single maximal versus combination punch kinematics.

    Science.gov (United States)

    Piorkowski, Barry A; Lees, Adrian; Barton, Gabor J

    2011-03-01

    The aim of this study was to determine the influence of punch type (Jab, Cross, Lead Hook and Reverse Hook) and punch modality (Single maximal, 'In-synch' and 'Out of synch' combination) on punch speed and delivery time. Ten competition-standard volunteers performed punches with markers placed on their anatomical landmarks for 3D motion capture with an eight-camera optoelectronic system. Speed and duration between key moments were computed. There were significant differences in contact speed between punch types (F(2,18,84.87) = 105.76, p = 0.001) with Lead and Reverse Hooks developing greater speed than Jab and Cross. There were significant differences in contact speed between punch modalities (F(2,64,102.87) = 23.52, p = 0.001) with the Single maximal (M+/- SD: 9.26 +/- 2.09 m/s) higher than 'Out of synch' (7.49 +/- 2.32 m/s), 'In-synch' left (8.01 +/- 2.35 m/s) or right lead (7.97 +/- 2.53 m/s). Delivery times were significantly lower for Jab and Cross than Hook. Times were significantly lower 'In-synch' than a Single maximal or 'Out of synch' combination mode. It is concluded that a defender may have more evasion-time than previously reported. This research could be of use to performers and coaches when considering training preparations.

  18. NCDC Punched Card Inventory - 1950s

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Index of foreign weather data available on punched cards held at the Joint Punched Card Library in Asheville NC, produced in the late 1950s, and also station/data...

  19. Punch Biopsy Results in Misdiagnosis of Pilomatrixoma

    Directory of Open Access Journals (Sweden)

    Metin Temel

    2017-03-01

    Full Text Available Punch biopsy results in misdiagnosis of clinically unsuspected giant pilomatrixoma located over the parotid gland. This study presents a case of pilomatrixoma that was misdiagnosed as a malignant epithelial tumor using punch biopsy. A 25-year-old male was admitted to our clinic for the evaluation of a mass measuring 7×8×8 cm located over the parotid gland. The patient had previously undergone punch biopsy at another clinic because of a lesion in the parotid gland. Punch biopsy revealed a malignant epithelial tumor. The patient underwent excisional biopsy at our clinic. After the biopsy, the residual skin defect was treated using full-thickness skin grafts. The facial nerve and parotid gland were preserved during the biopsy. Histopathological examination of the excisional biopsy material revealed pilomatrixoma. Punch biopsy may result in misdiagnosis of skin lesions in the parotid gland. A differential diagnosis for benign tumors such as pilomatrixoma is essential prior to an aggressive surgical intervention of the parotid gland.

  20. Recent progress in shear punch testing

    International Nuclear Information System (INIS)

    Hamilton, M.L.; Toloczko, M.B.; Lucas, G.E.

    1994-09-01

    The shear punch test was developed in response to the needs of the materials development community for small-scale mechanical properties tests. Such tests will be of great importance when a fusion neutron simulation device is built, since such a device is expected to have a limited irradiation volume. The shear punch test blanks a circular disk from a fixed sheet metal specimen, specifically a TEM disk. Load-displacement data generated during the test can be related to uniaxial tensile properties such as yield and ultimate strength. Shear punch and tensile tests were performed at room temperature on a number of unirradiated aluminum, copper, vanadium, and stainless steel alloys and on several irradiated aluminum alloys. Recent results discussed here suggest that the relationship between shear punch strength and tensile strength varies with alloy class, although the relationship determined for the unirradiated condition remains valid for the irradiated aluminum alloys

  1. A preclinical evaluation of an autologous living hyaline-like cartilaginous graft for articular cartilage repair: a pilot study

    OpenAIRE

    Yvonne Peck; Pengfei He; Geetha Soujanya V. N. Chilla; Chueh Loo Poh; Dong-An Wang

    2015-01-01

    In this pilot study, an autologous synthetic scaffold-free construct with hyaline quality, termed living hyaline cartilaginous graft (LhCG), was applied for treating cartilage lesions. Implantation of autologous LhCG was done at load-bearing regions of the knees in skeletally mature mini-pigs for 6 months. Over the course of this study, significant radiographical improvement in LhCG treated sites was observed via magnetic resonance imaging. Furthermore, macroscopic repair was effected by LhCG...

  2. Analysis of Pick-Up Development in Punching

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2002-01-01

    The development of pick-up of work piece material on the punch surface with increasing number of strokes during punching of stainless steel sheet is investigated applying Scanning Electron Microscopy (SEM), 3D roughness mapping and measurements of the backstroke force. It is found that pick...

  3. Small Punch Test Techniques for Irradiated Materials in Hot Cell

    International Nuclear Information System (INIS)

    Kim, Do Sik; Ahn, S. B.; Oh, W. H.; Yoo, B. O.; Choo, Y. S.

    2006-06-01

    Detailed procedures of the small punch test including the apparatus, the definition of small punch-related parameters, and the interpretation of results were presented. The testing machine should have a capability of the compressive loading and unloading at a given deflection level. The small punch specimen holder consists of an upper and lower die and clamping screws. The clamped specimen is deformed by using ball or spherical head punch. Two type of specimens with a circular and a square shape were used. The irradiated small punch specimen is made from the undamaged portion of the broken CVN bars or prepared by the irradiation of the specimen fabricated from the fresh materials. The heating and cooling devices should have the capability of the temperature control within ±2 .deg. C for the target value during the test. Based on the load-deflection data obtained from the small punch test. the empirical correlation between the small punch related parameters and a tensile properties such as 0.2% yield strength and ultimate tensile strength, fracture toughness, ductile-brittle transition temperature and creep properties determined from the standard test method is established and used to evaluate the mechanical properties of an irradiated materials. In addition, from the quantitative fractographic assessment of small punch test specimens, the relationship between the small punch energy and the quantity of ductile crack growth is obtained. Analytical formulations demonstrated good agreement with experimental load-deflection curves

  4. Optimization of fruit punch using mixture design.

    Science.gov (United States)

    Kumar, S Bharath; Ravi, R; Saraswathi, G

    2010-01-01

    A highly acceptable dehydrated fruit punch was developed with selected fruits, namely lemon, orange, and mango, using a mixture design and optimization technique. The fruit juices were freeze dried, powdered, and used in the reconstitution studies. Fruit punches were prepared according to the experimental design combinations (total 10) based on a mixture design and then subjected to sensory evaluation for acceptability. Response surfaces of sensory attributes were also generated as a function of fruit juices. Analysis of data revealed that the fruit punch prepared using 66% of mango, 33% of orange, and 1% of lemon had highly desirable sensory scores for color (6.00), body (5.92), sweetness (5.68), and pleasantness (5.94). The aroma pattern of individual as well as combinations of fruit juices were also analyzed by electronic nose. The electronic nose could discriminate the aroma patterns of individual as well as fruit juice combinations by mixture design. The results provide information on the sensory quality of best fruit punch formulations liked by the consumer panel based on lemon, orange, and mango.

  5. Applying a punch with microridges in multistage deep drawing processes.

    Science.gov (United States)

    Lin, Bor-Tsuen; Yang, Cheng-Yu

    2016-01-01

    The developers of high aspect ratio components aim to minimize the processing stages in deep drawing processes. This study elucidates the application of microridge punches in multistage deep drawing processes. A microridge punch improves drawing performance, thereby reducing the number of stages required in deep forming processes. As an example, the original eight-stage deep forming process for a copper cylindrical cup with a high aspect ratio was analyzed by finite element simulation. Microridge punch designs were introduced in Stages 4 and 7 to replace the original punches. In addition, Stages 3 and 6 were eliminated. Finally, these changes were verified through experiments. The results showed that the microridge punches reduced the number of deep drawing stages yielding similar thickness difference percentages. Further, the numerical and experimental results demonstrated good consistency in the thickness distribution.

  6. Development of lubricant test for punching and blanking

    DEFF Research Database (Denmark)

    Olsson, David Dam

    2001-01-01

    The background for development of new lubricants Requirements to lubricant test for punching Methods of evaluating lubricants Test equipment developed at DTU Conclusion.......The background for development of new lubricants Requirements to lubricant test for punching Methods of evaluating lubricants Test equipment developed at DTU Conclusion....

  7. Powder properties and compaction parameters that influence punch sticking propensity of pharmaceuticals.

    Science.gov (United States)

    Paul, Shubhajit; Taylor, Lisa J; Murphy, Brendan; Krzyzaniak, Joseph F; Dawson, Neil; Mullarney, Matthew P; Meenan, Paul; Sun, Changquan Calvin

    2017-04-15

    Punch sticking is a frequently occurring problem that challenges successful tablet manufacturing. A mechanistic understanding of the punch sticking phenomenon facilitates the design of effective strategies to solve punch sticking problems of a drug. The first step in this effort is to identify process parameters and particle properties that can profoundly affect sticking performance. This work was aimed at elucidating the key material properties and compaction parameters that influence punch sticking by statistically analyzing punch sticking data of 24 chemically diverse compounds obtained using a set of tooling with removable upper punch tip. Partial least square (PLS) analysis of the data revealed that particle surface area and tablet tensile strength are the most significant factors attributed to punch sticking. Die-wall pressure, ejection force, and take-off force also correlate with sticking, but to a lesser extent. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Measurement of tensile and fracture toughness properties using small punch test

    International Nuclear Information System (INIS)

    Chatterjee, S.; Shah Priti Kotak

    2005-05-01

    Small punch test wu carried out at room temperature on five different steels using 10 mm by 10 mm specimens of 0.4 mm thickness in a univesal testing machine. The tensile and fracture toughness properties of the five steels obtained from small punch test were compared with those obtained from the standard test method. The results (except in one steel) show that the tensile properties obtained from small punch test are in close proximity to those obtained ftom uni-axial tension test. The results also show that fracture toughness (Jic) properties obtained ftom small punch test are within ±20% of the corresponding values obtained using standard test procedures. (author)

  9. Research on the Visual Processing System of the Punch Press

    Directory of Open Access Journals (Sweden)

    Sun Xuan

    2016-01-01

    Full Text Available Most of raw materials of small hardware processing for plate scraps, and it’s realized through the manual operation of ordinary punch, which way has the low production efficiency and the high labor intensity. In order to improve the automation level of production, developing and designing of a visual processing system for punch press manipulator which based on the MFC tools of Visual Studio software platform. Through the image acquisition and image processing, get the information about the board to be processed, such as shape, length, the center of gravity position and pose, and providing relevant parameters for positioning gripping and placing into the punch table positioning of the feeding manipulator and automatic programming of punching machine, so as to realize the automatic operation about press feeding and processing.

  10. A new virtual instrument for estimating punch velocity in combat sports.

    Science.gov (United States)

    Urbinati, K S; Scheeren, E; Nohama, P

    2013-01-01

    For improving the performance in combat sport, especially percussion, it is necessary achieving high velocity in punches and kicks. The aim of this study was to evaluate the applicability of 3D accelerometry in a Virtual Instrumentation System (VIS) designed for estimating punch velocity in combat sports. It was conducted in two phases: (1) integration of the 3D accelerometer with the communication interface and software for processing and visualization, and (2) applicability of the system. Fifteen karate athletes performed five gyaku zuki type punches (with reverse leg) using the accelerometer on the 3rd metacarpal on the back of the hand. It was performed nonparametric Mann-Whitney U-test to determine differences in the mean linear velocity among three punches performed sequentially (p sport.

  11. Effects of plyometric exercise training with external weights on punching ability of experienced amateur boxers.

    Science.gov (United States)

    Bruzas, Vidas; Kamandulis, Sigitas; Venckunas, Tomas; Snieckus, Audrius; Mockus, Pranas

    2018-03-01

    During competition, a boxer must continue to deliver high-impact punches despite increasing fatigue. It is unclear whether the effects of plyometric training using external weights are transferred to sport-specific movements such as punching. The aim of the study was to investigate the effects of a 4-week cycle of plyometric training with external weights on punching ability. The study involved eight male amateur boxers aged 22.3±2.5 years with at least 7 years of competitive experience. They performed 12 plyometric training sessions, each comprising eight exercises of various muscle groups performed at maximum movement velocity. Six drills were performed with external weights, and two drills were performed using the body weight as resistance. All exercises required coordination. The punching ability was tested at baseline and after the 4 weeks of training using the Kiktest-100 boxing bag. The force of single punches and the frequency of punches within a series did not change from before to after the 4 weeks, except for increased power in the rear-hand low punch (Pplyometric training with external weights did not change the maximum punching power or movement frequency significantly, but had a beneficial effect on punching power endurance in boxers.

  12. Configurational phases in elastic foams under lengthscale-free punching

    Science.gov (United States)

    Sabuwala, Tapan; Dai, Xiangyu; Gioia, Gustavo

    2016-08-01

    We carry out experiments with brick-like specimens of elastic open-cell (EOC) foams of three relative densities. Individual specimens may be "tall" (height = width = depth) or "short" (2 height = width = depth). We place each specimen on a supporting plate and use a lengthscale-free (wedge-shaped or conical) punch to apply forces downward along the specimen's height. Regardless of the type of specimen, the force-penetration curves remain linear, for the wedge-shaped punch, or quadratic, for the conical punch, up to a sizable penetration commensurate with the smallest lengthscale of the specimen. After that there is an abrupt, all-but-discontinuous change in stiffness: if the specimen is tall, the stiffness drops; if the specimen is short, the stiffness shoots up. To analyze these curious experimental results, we posit that EOC foams can be found in either of two configurational phases, here termed the low-strain phase and the high-strain phase, which share a two-dimensional interface (a surface of strain discontinuity). The analysis may be outlined as follows. In the first part of an experiment, there obtains a "similarity regime" in which the penetration of the punch and the radius of the interface are the only prevailing lengthscales (because the punch is lengthscale free). In this case, it is possible to show that the force-penetration curve must be linear, or quadratic, depending on whether the punch be wedge-shaped or conical, respectively. This prediction of the analysis is consistent with the experiments. In time, the similarity regime breaks down when the interface reaches one of the specimen's boundaries distal to the tip of the punch. If the specimen is tall, the soft, stress-free lateral boundary is reached first, and the stiffness must drop; if the specimen is short, the hard boundary in contact with the supporting plate is reached first, and the stiffness must shoot up. These predictions too are consistent with the experiments. To provide direct

  13. Relationship between strain and central deflection in small punch creep specimens

    International Nuclear Information System (INIS)

    Yang Zhen; Wang Zhiwen

    2003-01-01

    Acquiring information about creep strain directly from small punch creep tests is difficult because the deformation behaviour of the small punch specimen is complicated. A routine is suggested in the present paper to treat this problem indirectly. Based on a finite element analysis, it is proposed that the relationship of central deflection δ to central creep strain ε c of a specimen subjected to creep can be represented approximately by the relationship of central deflection δ to central (elastic-plastic) strain ε of a specimen not subjected to creep. With this hypothesis, the δ∼ε c relation of the small punch creep specimen is obtained by resorting to a rigid-plastic membrane stretch forming model. Finally, small punch creep test results are used to evaluate creep strain and creep strain rate by taking advantage of this δ∼ε c relation

  14. Countering Stryker’s Punch: Algorithmically Filling the Black Hole

    OpenAIRE

    Michael J. Bennett

    2017-01-01

    Two current digital image editing programs are examined in the context of filling in missing visual image data from hole-punched United States Farm Security Administration (FSA) negatives. Specifically, Photoshop's Content-Aware Fill feature and GIMP's Resynthesizer plugin are evaluated and contrasted against comparable images. A possible automated workflow geared towards large scale editing of similarly hole-punched negatives is also explored. Finally, potential future research based upon th...

  15. Analysis of the Strength on the Rotor Punching Sheet of Nuclear Reactor Cooling Medium Driving Motor

    Directory of Open Access Journals (Sweden)

    GE Bao-jun

    2017-02-01

    Full Text Available A strong stress is withstood by the rotor punching sheet during the running of nuclear reactor cooling medium driving motor. In order to study the strength on the rotor punching sheet and the influential factor of its stress,the rotor of driving motor was the research object, the three-dimensional rotor model of driving motor is established by the finite element method to obtain the Mires equivalent stress nephogram and check the rotor’s strength with setting parameters and constraints. According to different rotor speeds,the different average temperatures of rotor punching sheet and shaft and the different static magnitude of interference between rotor punching sheet and shaft,the research about how the contact pressure of matching surface between rotor punching sheet and shaft and the Mires equivalent stress are impacted is carried on. The results show that the maximum Miser equivalent stress value of rotor punching sheet emerges on the axial vents,the stress value is beyond the tensile limit of the materialand. The greater the static magnitude of interference and the smaller temperature difference of rotor punching sheet and shaft lead to the greater interface compressive stress of rotor punching sheet and shaft and the greater maximum Mires equivalent stress value of rotor punching sheet. The higher the rotor speed lead to the smaller interface compressive stress of rotor punching sheet and shaft and the greater equivalent stress value of rotor punching sheet.

  16. Effect of Punch Stroke on Deformation During Sheet Forming Through Finite Element

    Science.gov (United States)

    Akinlabi, Stephen; Akinlabi, Esther

    2017-08-01

    Forming is one of the traditional methods of making shapes, bends and curvature in metallic components during a fabrication process. Mechanical forming, in particular, employs the use of a punch, which is pressed against the sheet material to be deformed into a die by the application of an external force. This study reports on the finite element analysis of the effects of punch stroke on the resulting sheet deformation, which is directly a function of the structural integrity of the formed components for possible application in the automotive industry. The results show that punch stroke is directly proportional to the resulting bend angle of the formed components. It was further revealed that the developed plastic strain increases as the punch stroke increases.

  17. Experimental and Numerical Simulation Research on Micro-Gears Fabrication by Laser Shock Punching Process

    OpenAIRE

    Huixia Liu; Jianwen Li; Zongbao Shen; Qing Qian; Hongfeng Zhang; Xiao Wang

    2015-01-01

    The aim of this paper is to fabricate micro-gears via laser shock punching with Spitlight 2000 Nd-YAG Laser, and to discuss effects of process parameters namely laser energy, soft punch properties and blank-holder on the quality of micro-gears deeply. Results show that dimensional accuracy is the best shocked at 1690 mJ. Tensile fracture instead of shear fracture is the main fracture mode under low laser energy. The soft punch might cause damage to punching quality when too high energy is emp...

  18. Percutaneous carpal tunnel release compared with mini-open release using ultrasonographic guidance for both techniques.

    Science.gov (United States)

    Nakamichi, Ken-ichi; Tachibana, Shintaro; Yamamoto, Seizo; Ida, Masayoshi

    2010-03-01

    To compare the outcomes of percutaneous carpal tunnel release (PCTR) and mini-open carpal tunnel release (mini-OCTR) using ultrasonographic guidance for both techniques. We included 74 hands of 65 women with idiopathic carpal tunnel syndrome (age, 52-71 y; mean, 58 y). Thirty-five hands of 29 women had the PCTR (release with a device consisting of an angled blade, guide, and holder, along a line midway between the median nerve and ulnar artery (safe line) under ultrasonography (incision, 4 mm), and 39 hands of 36 women had the mini-OCTR (release along the safe line, distally under direct vision (incision, 1-1.5 cm) and proximally under ultrasonography, using a device consisting of a basket punch and outer tube. Assessments at 3, 6, 13, 26, 52, and 104 weeks showed no significant differences in neurologic recovery between the groups (p > .05). The PCTR group had significantly less pain, greater grip and key-pinch strengths, and better satisfaction scores at 3 and 6 weeks (p < .05), and less scar sensitivity at 3, 6, and 13 weeks (p < .05). There were no complications. The PCTR provides the same neurologic recovery as does the mini-OCTR. The former leads to less postoperative morbidity and earlier functional return and achievement of satisfaction. Therapeutic III. Copyright 2010. Published by Elsevier Inc.

  19. Shear punch tests performed using a new low compliance test fixture

    International Nuclear Information System (INIS)

    Toloczko, M.B.; Kurtz, R.J.; Hasegawa, A.; Abe, K.

    2002-01-01

    Based on a recent finite element analysis (FEA) study performed on the shear punch test technique, it was suggested that compliance in a test frame and fixturing which is quite acceptable for uniaxial tensile tests, is much too large for shear punch tests. The FEA study suggested that this relatively large compliance was masking both the true yield point and the shape of the load versus displacement trace obtained in shear punch tests. The knowledge gained from the FEA study was used to design a new shear punch test fixture which more directly measures punch tip displacement. The design of this fixture, the traces obtained from this fixture, and the correlation between uniaxial yield stress and shear yield stress obtained using this fixture are presented here. In general, traces obtained from the new fixture contain much less compliance resulting in a trace shape which is more similar in appearance to a corresponding uniaxial tensile trace. Due to the more direct measurement of displacement, it was possible to measure yield stress at an offset shear strain in a manner analogous to yield stress measurement in a uniaxial tensile test. The correlation between shear yield and uniaxial yield was altered by this new yield measurement technique, but the new correlation was not as greatly improved as was suggested would occur from the FEA study

  20. Flat punch adhesion: transition from fracture-based to strength-limited pull-off

    International Nuclear Information System (INIS)

    Jiang, Yijie; Turner, Kevin T; Grierson, David S

    2014-01-01

    The adhesion of a cylindrical flat punch to a surface due to interatomic forces is a well-known problem that is important in many applications, including indentation experiments and the adhesion of fibrillar structures. Traditionally, the pull-off force has been related to the work of adhesion and punch geometry via the Kendall solution that uses a Griffith energy balance to assess crack propagation and pull-off. More recently, it has been shown that under certain conditions, notably at small punch diameters, the contact can behave in a ‘strength-limited’ fashion in which the interface separates uniformly rather than via crack propagation. Here, a Maugis-Dugdale-type analysis of power-law-shaped bodies in contact is used to examine the change in behaviour from the fracture-based Kendall solution to strength-limited pull-off for cylindrical flat punches. The transition from fracture-based to strength-limited behaviour is described in terms of a non-dimensional parameter that is similar to previous quantities used to describe the transition and is a function of the punch size, the elasticity of the contact, and the adhesion properties. The results of this relatively simple analysis compare favourably with results from more complex computational simulations. In addition, the results are used to develop a function that quantifies the transition between the Kendall solution and the strength-limited solution in order to facilitate interpretation of adhesion measurements in the transition regime between the two limits. Finally, the power-law analysis is used to assess the sensitivity of the transition to the exact shape of the punch. (paper)

  1. Shear punch testing as a tool for evaluating welded pipeline steel

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, G.R.; Elwazri, A.; Varano, R.; Yue, S.; Jonas, J.J. [McGill Univ., Montreal, PQ (Canada). Dept. of Metals and Materials Engineering; Pokutylowicz, N. [ExxonMobil Research and Engineering Co., Annandale, NJ (United States)

    2005-07-01

    This study examined the mechanical properties across a welded joint in a 35 mm steel pipe. Results were compared with microhardness measurements. The chemical composition of the 4130 steel and welding wire included carbon, manganese, silicon, nickel, chromium and molybdenum. The thermal cycles experienced during welding can result in differences in the grain size, phase, composition and morphology of precipitates. These thermal cycles can upset the balance of high strength and good toughness in steels, producing poor toughness in the heat-affected zone (HAZ). In the shear punch test, a flat-ended cylindrical punch was used to produce a 3 mm diameter disk from a sheet specimen with a recommended thickness of 300 to 350 {mu}m. The shear punch test provided tensile property data with only a very small amount of material, which is ideal for testing welds. It also provides full tensile data (yield strength, ultimate tensile strength and elongation) which are not specifically provided by hardness testing. Shear punch techniques can also improve the across-weld resolution of tensile testing. The results showed that the changes in strength properties across the weld were consistent with the microhardness measurements. The change in elongation across the weld joint was successfully measured using the punch test method. The HAZ in the welded joint in this study had a good combination of high strength and ductility, while the weld bead had moderate strength and relatively low ductility. 7 refs., 1 tab., 9 figs.

  2. Blanking Clearance and Punch Velocity Effects on The Sheared Edge Characteristic in Micro-Blanking of Commercially Pure Copper Sheet

    OpenAIRE

    Didin Zakaria Lubis; Ichsan Ristiawan

    2017-01-01

    This study aims to identify the influences between clearance and punch velocity on the part edge quality of blanked parts. Experiments have been conducted using material copper, punch-die clearance and punch velocity variations. In order to determine the reachable punch-die clearance and punch velocity required for blanking. The quality of the part-edge characteristics shows that higher punch velocity and decreases clearance value can improve the part-edge quality, resulting in smaller burr h...

  3. Mini-open transforaminal lumbar interbody fusion.

    Science.gov (United States)

    Tangviriyapaiboon, Teera

    2008-09-01

    To demonstrate the surgical technique and advantages of the mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation. Clinical and radiographic results were assessed to determine the clinical outcomes in twelve consecutive patients selected for minimally invasive access (mini-open technique) for TLIF in Prasat Neurological Institute. A retrospective analysis was performed on 12 patients (age range, 38-74 yr; mean, 54. 8 yr) who underwent mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation between September 2006 and June 2008. The titanium pedicle screws were introduced bilaterally through the 3.5 cm length, skin incisions with Spine Classics MLD- system retractor, autologous bone graft were inserted to perform TLIF in all patients. Eight patients were augmented anterior column support with titanium interbody cage, unilateral cage insertion in four patients and the others were inserted bilaterally interbody cages. Six patients presented with low back pain and associated radiculopathy, and six presented with low back pain only. Transforaminal lumbar interbody fusion was performed at L3-L4 in two patients, L4-L5 in four patients, L5-S1 in five patients, and two levels fusion in one patient. All patients were able to ambulate after spinal fusion. The patients were able to walk within 1.4 days (range 1-2 days). The hospital stay averaged 4.4 days (range 3-7 days). Periodic follow-up took place 1 to 21 months after surgery (mean, 7.4 months). The radiological fusion was archived in all nine patients who were operated on more than two months age. The other three patients who had been follow-up less than two months were probably fusion on the 1-month followed-up radiological examination. The use of mini-open technique for pedicle screw instrumentation with spinal fusion procedure provides excellent clinical results and may be an operation of choice for

  4. Vibration Control of a High-Speed Precision Servo Numerically Controlled Punching Press: Multidomain Simulation and Experiments

    Directory of Open Access Journals (Sweden)

    Teng Xu

    2017-01-01

    Full Text Available A three-degree-of-freedom mathematical vibration model of a high-speed punching press was developed in order to explore the vibration modes of the punching press. A multidomain model of the punching press was established to predict the kinematic state during different conditions, as well as the effects of load fluctuation on the motor speed. Experimental measurements of the acceleration of the punching press were carried out. The results comparison reveals that the multidomain model is consistent with the vibration model and the experimental measurements. Modal analysis and structure modification of the punching press were conducted. The foundation at the base of the punching press was improved against excess of vibration. The effects of the dimensions of the foundation on the vibration were discussed with the aid of the multidomain model. Finally, proper foundation design, able to reduce the vibration, was obtained.

  5. Analysis of ancient Indian silver punch-marked coins by external PIXE

    International Nuclear Information System (INIS)

    Rautray, Tapash R.; Nayak, Suman S.; Tripathy, Bipin B.; Das, Saubhagyalaxmi; Das, Manas R.; Das, Satya R.; Chattopadhyay, Pranab K.

    2011-01-01

    Seven silver punch-marked coins were analysed using external particle induced X-ray emission technique. The main group of elements like Ag, Cu, Au, Pb and Fe were estimated along with a number of trace/minor elements such as K, Ca, Ti, V, Cr, Mn, Co, Ni and Rb in the analysed silver coins. Gold was found in all the coins and varied between 0.7% and 6.2% indicating the better economic condition of that civilisation. - Highlights: → The silver punch-marked coins, in the current study, were in use in India between 6th century BC to 6th century AD and have been analysed by in-air PIXE. → These sets of coins have immense archaeological importance because of their very rare availability. → These coins are distinguished from other coins because of the presence of gold as major element. → While the British period coins were fabricated using modern technologies, the punch-marked coins were shaped manually with developed metal technology. → The analysis of punch-marked coins using external PIXE beam has been done for the first time, which is unique of its kind.

  6. Small punch test evaluation methods for material characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Janča, Adam, E-mail: adam.janca@fjfi.cvut.cz; Siegl, Jan, E-mail: jan.siegl@fjfi.cvut.cz; Haušild, Petr, E-mail: petr.hausild@fjfi.cvut.cz

    2016-12-01

    The Small Punch Test (SPT) is one of the most widespread mechanical testing methods using miniaturized specimens. The paper presented deals with the time independent SPT, in which a flat specimen is bent by means of a (hemi)spherical punch moving at a constant velocity. The main goal is to relate the measured data to deformation processes taking place during specimen loading. Understanding of such relations is crucial for characterizing a material using any non-standardized experimental procedure. Using enhanced instrumentation, not only traditional load-displacement or load-deflection curves could be obtained, but also specimen thinning could be continuously measured and evaluated. Five alloys having a broad range of mechanical properties were tested. The results obtained were evaluated using both traditional and newly proposed methods and they were correlated with results of the conventional tensile test. The methods proposed seem to lead to a universal correlation between SPT results and tensile characteristics. - Highlights: • The newly proposed methodology significantly improved results of SPT. • Plastic deformation starts inside the specimen from the very beginning of loading. • Specimen thinning = punch displacement−specimen deflection. • Material response to loading is well illustrated by the novel load-thinning curve.

  7. Damage modeling in Small Punch Test specimens

    DEFF Research Database (Denmark)

    Martínez Pañeda, Emilio; Cuesta, I.I.; Peñuelas, I.

    2016-01-01

    . Furthermore,Gurson-Tvergaard-Needleman model predictions from a top-down approach are employed to gain insightinto the mechanisms governing crack initiation and subsequent propagation in small punch experiments.An accurate assessment of micromechanical toughness parameters from the SPT...

  8. The Influence of a Padded Hand Wrap on Punching Force in Elite and Untrained Punchers

    Directory of Open Access Journals (Sweden)

    Andrew J. Galpin

    2015-10-01

    Full Text Available Punching is integral to success in combat sports, making it a frequent activity during practice/training. Improving safety of this activity benefits both the athlete and training partners. This study was designed to 1 test the precision and reliability of a commercially available striking device and 2 assess the influence of a novel padded hand wrap on punching force in elite and untrained punchers. Fourteen male professional boxers and mixed martial artists (PRO; age=29.2±5.6y; height=180.3±9.0cm; mass=87.1±17.9kg, winning %=73.8±13.8%, number of victories via knockout/technical knockout=35.6± 21.9% and 24 untrained male punchers (UNT; 27.6±6.9y, 177.6±18.3cm, 84.3±16.9kg wore a standardized boxing glove and performed 20 maximal punches (4 sets of 5 into a device designed to measure punching force. All participants performed, in a counterbalanced order, 2 sets of 5 with a standardized hand wrap and 2 sets of 5 with the same wrap plus an additional 1.2cm thick cylinder 4g foam-like pad (WRAP placed over the knuckles. PRO produced significantly more punching force than UNT, regardless of condition. Punching force was lower by 12.6% (p<0.05 for PRO and 8.9% (p<0.05 for UNT with WRAP (compared to no WRAP. These findings suggest WRAP significantly reduces punching force, which may be important for long-term safety of the puncher’s hand and/or the person receiving the strike. Keywords: safety, punching, striking, hitting, combat, pad

  9. FORTRAN text correction with the CDC-1604-A console typewriter during reading a punched card program

    International Nuclear Information System (INIS)

    Kotorobaj, F.; Ruzhichka, Ya.; Stolyarskij, Yu.V.

    1977-01-01

    The paper describes FORTRAN text correction with the CDC 1604-A console typewriter during reading a punched card program. This method gives one more possibility of FORTRAN program correction during program's input to the CDC 1604-A computer. This essentially reduced the time necessary for punched card correction with other methods. Possibility of inputting desired number of punched cards one after another allows one writing small FORTRAN programs to computer core storage with simultaneous punching of the cards. The correction program has been written to the CDC 1604 COOP monitor

  10. Shear punch and microhardness tests for strength and ductility measurements

    International Nuclear Information System (INIS)

    Lucas, G.E.; Odette, G.R.; Sheckherd, J.W.

    1983-01-01

    In response to the requirements of the fusion reactor materials development program for small-scale mechanical property tests, two techniques have been developed, namely ball microhardness and shear punch tests. The ball microhardness test is based on the repeated measurement at increasing loads of the chordal diameter of an impression made by a spherical penetrator. A correlation has been developed to predict the constitutive relation of the test material from these data. In addition, the indentation pile-up geometry can be analyzed to provide information on the homogeneity of plastic flow in the test material. The shear punch test complements the microhardness test. It is based on blanking a circular disk from a fixed sheet metal specimen. The test is instrumented to provide punch load-displacement data, and these data can be used to determine flow properties of the test material such as yield stress, ultimate tensile strength, work-hardening exponent, and reduction of area

  11. Very heavy iron-punching concretes; Betons tres lourds a base de riblons

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, F [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1966-07-01

    The present report deals with all the heavy iron-punching concretes, metallic wastes produced by the transformation industry. After a detailed description of the physical properties of metallic aggregates, a classification of heavy mortars is given, into three main categories: steel-shot grouts d = 5,3 - 6; steel-shot grouts mixed with a mineral d = 3,7 - 4,2; injection heavy grouts d = 3,5 - 4. The following chapter describes iron-punching concretes the most used in the atomic industry: iron-punching concretes mixed with cast-iron - iron-punching concretes mixed with magnetite; iron-punching concretes mixed with barite; iron-punching concretes mixed with limonite; iron-punching concretes mixed with boron. The compositions of these concretes are given together with their physical and mechanical characteristics. Numerous diagrams make it possible to find rapidly the proportions of the constituents of these concretes as a function of the required density. Technical advice and specifications are given in an appendix together with a bibliography of these heavy concretes. (author) [French] Le present rapport traite de l'ensemble des betons lourds realises a l'aide de riblons, dechets metalliques fournis par l'industrie de transformation. Apres une description detaillee des proprietes physiques des agregats metalliques, les mortiers lourds sont d'abord presentes en les classant en trois grandes categories: les mortiers a base de grenailles d 5,3 a 6; les mortiers a base de grenailles avec addition d'un mineral d 3,7 a 4,2; les mortiers lourds injectables d = 3,5 a 4. Le chapitre suivant decrit les betons a base de riblons les plus utilises, dans l'industrie atomique: les betons de riblons avec addition de fonte; les betons de riblons avec addition de magnetite; les betons de riblons avec addition de barytine; les betons de riblons avec addition de limonite; les betons de riblons avec addition de bore. Les compositions de ces betons ainsi que leurs caracteristiques

  12. Very heavy iron-punching concretes; Betons tres lourds a base de riblons

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, F. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1966-07-01

    The present report deals with all the heavy iron-punching concretes, metallic wastes produced by the transformation industry. After a detailed description of the physical properties of metallic aggregates, a classification of heavy mortars is given, into three main categories: steel-shot grouts d = 5,3 - 6; steel-shot grouts mixed with a mineral d = 3,7 - 4,2; injection heavy grouts d = 3,5 - 4. The following chapter describes iron-punching concretes the most used in the atomic industry: iron-punching concretes mixed with cast-iron - iron-punching concretes mixed with magnetite; iron-punching concretes mixed with barite; iron-punching concretes mixed with limonite; iron-punching concretes mixed with boron. The compositions of these concretes are given together with their physical and mechanical characteristics. Numerous diagrams make it possible to find rapidly the proportions of the constituents of these concretes as a function of the required density. Technical advice and specifications are given in an appendix together with a bibliography of these heavy concretes. (author) [French] Le present rapport traite de l'ensemble des betons lourds realises a l'aide de riblons, dechets metalliques fournis par l'industrie de transformation. Apres une description detaillee des proprietes physiques des agregats metalliques, les mortiers lourds sont d'abord presentes en les classant en trois grandes categories: les mortiers a base de grenailles d 5,3 a 6; les mortiers a base de grenailles avec addition d'un mineral d 3,7 a 4,2; les mortiers lourds injectables d = 3,5 a 4. Le chapitre suivant decrit les betons a base de riblons les plus utilises, dans l'industrie atomique: les betons de riblons avec addition de fonte; les betons de riblons avec addition de magnetite; les betons de riblons avec addition de barytine; les betons de riblons avec addition de limonite; les betons de riblons avec addition de bore. Les compositions de ces betons ainsi que

  13. Examining the microtexture evolution in a hole-edge punched into 780 MPa grade hot-rolled steel

    Energy Technology Data Exchange (ETDEWEB)

    Shin, J.H.; Kim, M.S. [Department of Printed Electronics Engineering, Sunchon National University, 315 Maegok, Sunchon, Jeonnam 540-950 (Korea, Republic of); Kim, S.I.; Seo, S.J. [POSCO Technical Research Laboratories, Gwangyang 545-090 (Korea, Republic of); Choi, S.-H., E-mail: shihoon@sunchon.ac.kr [Department of Printed Electronics Engineering, Sunchon National University, 315 Maegok, Sunchon, Jeonnam 540-950 (Korea, Republic of)

    2016-08-15

    The deformation behavior in the hole-edge of 780 MPa grade hot-rolled steel during the punching process was investigated via microstructure characterization and computational simulation. Microstructure characterization was conducted to observe the edges of punched holes through the thickness direction, and electron back-scattered diffraction (EBSD) was used to analyze the heterogeneity of the deformation. Finite element analysis (FEA) that could account for a ductile fracture criterion was conducted to simulate the deformation and fracture behaviors of 780 MPa grade hot-rolled steel during the punching process. Calculation of rotation rate fields at the edges of the punched holes during the punching process revealed that metastable orientations in Euler space were confined to specific orientation groups. Rotation-rate fields effectively explained the stability of the initial texture components in the hole-edge region during the punching process. A visco-plastic self-consistent (VPSC) polycrystal model was used to calculate the microtexture evolution in the hole-edge region during the punching process. FEA revealed that the heterogeneous effective strain was closely related to the heterogeneity of the Kernel average misorientation (KAM) distribution in the hole-edge region. A simulation of the deformation microtexture evolution in the hole-edge region using a VPSC model was in good agreement with the experimental results. - Highlights: •We analyzed the microstructure in a hole-edge punched in HR 780HB steel. •Rotation rate fields revealed the stability of the initial texture components. •Heterogeneous effective stain was closely related to the KAM distribution. •VPSC model successfully simulated the deformation microtexture evolution.

  14. Frictionless contact of a rigid punch indenting a transversely isotropic elastic layer

    Directory of Open Access Journals (Sweden)

    Rajesh Patra

    2016-03-01

    Full Text Available This article is concerned with the study of frictionless contact between a rigid punch and a transversely isotropic elastic layer. The rigid punch is assumed to be axially symmetric and is being pressed towards the layer by an applied concentrated load. The layer is resting on a rigid base and is assumed to be ufficiently thick in comparison with the amount of indentation by the rigid punch. The relationship between the applied load $P$ and the contact area is obtained by solving the mathematically formulated problem through use of Hankel transform of different order. Effect of indentation on the distribution of normal stress at the surface as well as the relationship between the applied load and the area of contact have been shown graphically.

  15. Experimental and Numerical Simulation Research on Micro-Gears Fabrication by Laser Shock Punching Process

    Directory of Open Access Journals (Sweden)

    Huixia Liu

    2015-07-01

    Full Text Available The aim of this paper is to fabricate micro-gears via laser shock punching with Spitlight 2000 Nd-YAG Laser, and to discuss effects of process parameters namely laser energy, soft punch properties and blank-holder on the quality of micro-gears deeply. Results show that dimensional accuracy is the best shocked at 1690 mJ. Tensile fracture instead of shear fracture is the main fracture mode under low laser energy. The soft punch might cause damage to punching quality when too high energy is employed. Appropriate thickness and hardness of soft punch is necessary. Silica gel with 200 µm in thickness is beneficial to not only homogenize energy but also propagate the shock wave. Polyurethane films need more energy than silica gel with the same thickness. In addition, blank-holders with different weight levels are used. A heavier blank-holder is more beneficial to improve the cutting quality. Furthermore, the simulation is conducted to reveal typical stages and the different deformation behavior under high and low pulse energy. The simulation results show that the fracture mode changes under lower energy.

  16. A solution for the narrow rectangular punch

    NARCIS (Netherlands)

    Panek, C.F.; Kalker, J.J.

    1977-01-01

    This paper considers the problem of a rectangular flat ended punch acting on an elastic half-space. An approximate solution is generated through application of the elastic line integral equations. The results produced by this method are then compared with another approximate solution already

  17. Blanking Clearance and Punch Velocity Effects on The Sheared Edge Characteristic in Micro-Blanking of Commercially Pure Copper Sheet

    Directory of Open Access Journals (Sweden)

    Didin Zakaria Lubis

    2017-11-01

    Full Text Available This study aims to identify the influences between clearance and punch velocity on the part edge quality of blanked parts. Experiments have been conducted using material copper, punch-die clearance and punch velocity variations. In order to determine the reachable punch-die clearance and punch velocity required for blanking. The quality of the part-edge characteristics shows that higher punch velocity and decreases clearance value can improve the part-edge quality, resulting in smaller burr height and rollover, and a larger shear zone. Furthermore, it could be observed that the part-edge quality improvement when blanking with high punch velocity is much more distinct for stele than for copper. According to blanking theory, this improvement was expected because copper have much higher heat conduction coefficients. Therefore, the heat dissipates faster and the desired stress relief effect does not take place to the same degree as for stele.

  18. Love-type wave propagation in a pre-stressed viscoelastic medium influenced by smooth moving punch

    Science.gov (United States)

    Singh, A. K.; Parween, Z.; Chatterjee, M.; Chattopadhyay, A.

    2015-04-01

    In the present paper, a mathematical model studying the effect of smooth moving semi-infinite punch on the propagation of Love-type wave in an initially stressed viscoelastic strip is developed. The dynamic stress concentration due to the punch for the force of a constant intensity has been obtained in the closed form. Method based on Weiner-hopf technique which is indicated by Matczynski has been employed. The study manifests the significant effect of various affecting parameters viz. speed of moving punch associated with Love-type wave speed, horizontal compressive/tensile initial stress, vertical compressive/tensile initial stress, frequency parameter, and viscoelastic parameter on dynamic stress concentration due to semi-infinite punch. Moreover, some important peculiarities have been traced out and depicted by means of graphs.

  19. Effect of cutter tip angle on cutting characteristics of acrylic worksheet subjected to punch/die shearing

    Directory of Open Access Journals (Sweden)

    Masami Kojima

    2016-12-01

    Full Text Available This paper aims to describe the effect of tool geometry on cutting characteristics of a 1.0 mm thickness acrylic worksheet subjected to a punch/die shearing. A set of side-wedge punch and side-wedge die which had the edge angle of 30°, 60° and/or 90° was prepared and used for cutting off the worksheet. A load cell and a CCD camera were installed in the cutting system to investigate the cutting load resistance and the side-view deformation of the worksheet. From experimental results, it was revealed that a cracking pattern at a sheared zone was remarkably affected by the edge angle of cutting tool. A cracking direction was almost coincident to the edge angle when considering the punch/die edge angle of 30°, while any matching of them was not observed in case of the punch/die edge angle of 60°, 90°. By using the 30° side-wedge tool, a flat-smooth sheared surface was generated. When combing the punch edge angle of 90° and the die edge angle of 60°, the cracking profile was characterized by the both edge angles for each part (die and punch. Carrying out an elasto-plastic finite element method analysis of cutter indentation with a few of symmetric and asymmetric punch/die edges, the stress distribution and deformation flow at the sheared zone were discussed with the initiation of surface cracks

  20. Treatment of Die-Punch Fractures with 3D Printing Technology.

    Science.gov (United States)

    Chen, Chunhui; Cai, Leyi; Zhang, Chuanxu; Wang, Jianshun; Guo, Xiaoshan; Zhou, Yifei

    2017-07-19

    We evaluated the feasibility, accuracy and effectiveness of applying three-dimensional (3D) printing technology for preoperative planning for die-punch fractures. A total of 107 patients who underwent die-punch fracture surgery were enrolled in the study. They were randomly divided into two groups: 52 cases in the 3D model group and 55 cases in the routine group. A 3D digital model of each die-punch fracture was reconstructed in the 3D group. The 3D digital model was imported to a 3D printer to build the full solid model. The operation time, blood loss volume, and the number of intraoperative fluoroscopy were recorded. Follow-up was performed to evaluate the patients' surgical outcomes. Treatment of die-punch fractures using the 3D printing approach reduced the number of intraoperative fluoroscopy, blood loss volume, and operation time, but did not improve wrist function compared to those in the routine group. The patients wanted the doctor to use the 3D model to introduce the condition and operative plan because it was easier for them to understand. The orthopedic surgeons thought that the 3D model was useful for communicating with their patients, but their satisfaction with the preoperative plan was much lower than the benefit of using the 3D model to communicate with their patients. 3D printing technology produced more accurate morphometric information for orthopedists to provide personalized surgical planning and communicate better with their patients. However, it is difficult to use widely in the department of orthopedics.

  1. Prediction of punching shear capacities of two-way concrete slabs reinforced with FRP bars

    Directory of Open Access Journals (Sweden)

    Ibrahim M. Metwally

    2013-08-01

    Full Text Available Where corrosion of steel reinforcement is a concern, fiber-reinforced polymer (FRP reinforcing bar or grid reinforcement provides an alternative reinforcement for concrete flat slabs. The existing provisions for punching of slabs in most international design standards for reinforced concrete are based on tests of steel reinforced slabs. The elastic stiffness and bonding characteristics of FRP reinforcement are sufficiently different from those of steel to affect punching strength [1]. This paper evaluates the punching shear strength of concrete flat slabs reinforced with different types of fiber-reinforced polymer (FRP. A total of 59 full-size slabs were constructed and tested collected from the literature of FRP bars reinforced concrete slabs. The test parameters were the amount of FRP reinforcing bars, Young’s modulus of FRP bars, slab thickness, loaded areas and concrete compressive strength. The experimental punching shear strengths were compared with the available theoretical predictions, including the ACI 318 Code, BS 8110 Code, ACI 440 design guidelines, and a number of models proposed by some researchers in the literature. Two approaches for predicting the punching strength of FRP-reinforced slabs are examined. The first is an empirical new model which is considered as a modification of El-Gamal et al. [2] model. The second is a Neural Networks Technique; which has been developed to predict the punching shear capacity of FRP reinforced concrete slabs. The accuracies of both methods were evaluated against the experimental test data. They attained excellent agreement with available test results compared to the existing design formulas.

  2. Mini buffy coat photopheresis for children and critically ill patients with extracorporeal photopheresis contraindications.

    Science.gov (United States)

    Hackstein, Holger; Misterek, Joachim; Nockher, Angelika; Reiter, Alfred; Bein, Gregor; Woessmann, Willi

    2009-11-01

    Conventional extracorporeal photopheresis (ECP) has proven efficacy for the treatment of several diseases but is limited to patients with sufficient body weight. A novel simplified mini buffy coat ECP technique that allows treatment of small children and patients with apheresis contraindications has been developed. White blood cell (WBC)-rich buffy coat fractions were prepared from 5 to 8 mL/kg whole blood in a closed system, diluted, and ultraviolet A (UVA)-irradiated after addition of 8-methoxypsoralen (8-MOP). Apoptosis and cell death were analyzed by annexin V and 7-aminoactinomycin staining. Lymphocyte proliferation was measured after CD3/CD28 and phytohemagglutinin (PHA) stimulation. Autologous residual blood and UVA-irradiated buffy coat were returned to the patients. Fifty-six mini buffy coat ECP procedures were applied to three children with acute steroid-refractory skin graft-versus-host disease and apheresis contraindications. Mean whole blood and buffy coat volumes were 166 (+/-61.8) and 8 (+/-1.6) mL, respectively, and resulted in a hematocrit of 2.2% (+/-0.4) after saline dilution (median +/- SD). UVA irradiation of 8-MOP buffy coat preparations resulted in significant induction of WBC apoptosis at 48-72 hours (p laboratory side effects were observed during mini ECP procedures and the three patients responded to the therapy. Mini buffy coat ECP induces apoptosis and lymphocyte proliferation inhibition, both of which occur after standard ECP. This study proposes that mini buffy coat ECP be used as a simple and inexpensive alternative to classical ECP in children and adult patients with apheresis contraindications.

  3. Fabrication and loading of oral drug delivery microcontainers using hot punching

    DEFF Research Database (Denmark)

    Petersen, Ritika Singh; Borre, Mads T.; Keller, Stephan Sylvest

    2015-01-01

    In this paper, poly-l-lactic acid (PLLA) solution is spin coated to achieve a PLLA layer of 55 μm thickness. Hot punching with a Ni stamp is optimized to fabricate microcontainers in PLLA. Process optimization of thermal bonding of the microcontainers to a poly acrylic acid (PAA) layer is perform...... by modifying sample preparation and varying temperature. The fabricated microcontainers are loaded by hot punching in a spin coated drug polymer film of furosemide and poly-e-caprolactone (PCL)....

  4. Development of small punch tests for ductile-brittle transition temperature measurement of temper embrittled Ni-Cr steels

    International Nuclear Information System (INIS)

    Baik, J.M.; Kameda, J.; Buck, O.

    1983-01-01

    Small punch tests were developed to determine the ductile-brittle transition temperature of nickel-chromium (Ni-Cr) steels having various degrees of temper embrittlement and various microstructures. It was found that the small punch test clearly shows the ductile-brittle transition behavior of the temper-embrittled steels. The measured values were compared with those obtained from Charpy impact and uniaxial tensile tests. The effects of punch tip shape, a notch, and the strain rate on the ductile-brittle transition behavior were examined. It was found that the combined use of a notch, high strain rates, and a small punch tip strongly affects the ductile-brittle transition behavior. Considerable variations in the data were observed when the small punch tests were performed on coarse-grained steels. Several factors controlling embrittlement measurements of steels are discussed in terms of brittle fracture mechanisms

  5. A preclinical evaluation of an autologous living hyaline-like cartilaginous graft for articular cartilage repair: a pilot study.

    Science.gov (United States)

    Peck, Yvonne; He, Pengfei; Chilla, Geetha Soujanya V N; Poh, Chueh Loo; Wang, Dong-An

    2015-11-09

    In this pilot study, an autologous synthetic scaffold-free construct with hyaline quality, termed living hyaline cartilaginous graft (LhCG), was applied for treating cartilage lesions. Implantation of autologous LhCG was done at load-bearing regions of the knees in skeletally mature mini-pigs for 6 months. Over the course of this study, significant radiographical improvement in LhCG treated sites was observed via magnetic resonance imaging. Furthermore, macroscopic repair was effected by LhCG at endpoint. Microscopic inspection revealed that LhCG engraftment restored cartilage thickness, promoted integration with surrounding native cartilage, produced abundant cartilage-specific matrix molecules, and re-established an intact superficial tangential zone. Importantly, the repair efficacy of LhCG was quantitatively shown to be comparable to native, unaffected cartilage in terms of biochemical composition and biomechanical properties. There were no complications related to the donor site of cartilage biopsy. Collectively, these results imply that LhCG engraftment may be a viable approach for articular cartilage repair.

  6. Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge

    Directory of Open Access Journals (Sweden)

    Vinita Khandegar

    2018-06-01

    Full Text Available The electrocoagulation setup must be optimized in order to design an economically feasible process. Therefore, in this work, the effect of the punched aluminum electrode on the performance of the electrocoagulation (EC has been investigated. A series of experiments were performed for treatment of sewage wastewater using plane electrode and compare with punched electrodes. Effect of contact time, voltage, electrode spacing and stirring speed has been optimized for removal of Biochemical oxygen demand (BOD and Total dissolved solids (TDS. It was observed that the performance of electrocoagulation process increased using punched electrode. Also, the less operating cost noticed in punched electrode as compared to a plane electrode for (70–80% removal of BOD and TDS. These data would be useful in designing of an EC reactor to obtain high removal efficiency at low energy consumption. Keywords: Electrocoagulation, Sewage wastewater, Aluminum, Plane, Punched electrode

  7. Moment Capacity of Timber Reinforced with Punched Metal Plate Fasteners

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Ellegaard, Peter

    When designing timber trusses it is often found that the cross section controlling the dimensions of the top chord is located at a joint with a moment peak. However, the timber volume affected by the moment peak is rather limited and by embedding a punched metal plate in this area a reinforcement...... of the section is obtained, resulting in a more economic truss design. In order to develop design methods for sections with plate reinforcement, bending tests have been made. The timber is Swedish spruce of strength class K-18(S8) and K-24(S10) with a thickness of 45 mm. The punched metal plate is from Gang...

  8. Effect of CFRP and TRM Strengthening of RC Slabs on Punching Shear Strength

    Directory of Open Access Journals (Sweden)

    Husain Abbas

    Full Text Available Abstract The paper presents experiments involving punching of RC slabs strengthened using externally bonded carbon fiber reinforced polymer (CFRP sheet and textile reinforced mortar (TRM. Twelve RC slab specimens of two concrete grades (39.9 and 63.2 MPa and employing two strengthening schemes (CFRP and TRM were tested. Specimens were supported on two opposite edges. Experimental load-displacement variations show two peak loads in strengthened slabs and one peak followed by a plateau in control. Second peak or the plateau corresponds to the combined action of aggregate interlock and the dowel action of back face rebars and strengthening layers. The dowel action of back face rebars and strengthening layers had no role in ultimate punching load (i.e. first peak. Strengthened slabs showed 9-18% increase in ultimate punching load (i.e. first peak whereas there was significant increase in the second peak load (190-276% for CFRP; 55-136% for TRM and energy absorption (~66% for CFRP and 22-56% for TRM. An analytical model was also developed for predicting the punching shear strength (first and second peaks of strengthened slabs showing good comparison with experiments.

  9. Control program for punched paper tape for the PDP-8/1 computer

    International Nuclear Information System (INIS)

    German, U.

    1976-01-01

    A program was developed for the PDP-8/1 computer to control the punched paper tape supplied by the measuring instruments. Any departure from the program is detected by an optical reader which stops the tape and displays the error on an accumulator. This program which is suitable for large amounts of data punched on paper tape has been in use at the Beer-Sheva laboratories for detecting errors in the sample changing operation. (B.G.)

  10. Development and validation of the small punch test for UHMWPE used in total joint replacements

    Energy Technology Data Exchange (ETDEWEB)

    Edidin, A.A. [Drexel Univ., Philadelphia, PA (United States). School of Biomedical Engineering, Science and Health Systems; Howmedica Osteonics Corp., Allendale, NJ (United States); Kurtz, S.M. [Drexel Univ., Philadelphia, PA (United States). School of Biomedical Engineering, Science and Health Systems; Thomas Jefferson Univ., Philadelphia, PA (United States). Dept. of Orthopaedic Surgery; Exponent, Inc., Philadelphia, PA (United States)

    2001-07-01

    In order to better understand the mechanical effects of oxidative degradation, improved oxidative stability and crosslinking on ultra-high molecular weight polyethylene (UHMWPE), a unique miniature specimen mechanical testing technique, known as the small punch test, was developed for evaluating total joint replacement components. The small punch test involves deforming a disk-shaped specimen having a thickness of 0.5 mm and a diameter of 6.4 mm. In addition to its small specimen size, the small punch test differs from conventional testing in that deformation of the UHMWPE specimen occurs under multiaxial loading conditions. Using the small punch test, we have traced the evolution of mechanical behavior in UHMWPE after natural (shelf-storage) and accelerated aging conditions. In addition, we have determined relationships between the mechanical behavior of UHMWPE and the biologically relevant wear debris volume generated in total hip replacements. The small punch test has also been used to investigate the effects of radiation crosslinking which has been shown to improve the wear performance in an in vitro hip simulator. However, the crosslinking and subsequent thermal processes used to improve the wear behavior may compromise the native mechanical behavior by changing the ductility and toughness of the UHMWPE bearing. The primary objective of this study was to investigate which tradeoffs exist related to the mechanical behavior associated with various clinically available types of highly crosslinked and thermally treated UHMWPE. We also review the development and validation of the small punch disk bend test and highlight its application to problems of clinical relevance in both hip and knee arthroplasty. (orig.)

  11. Small punch creep test: A promising methodology for high temperature plant components life evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tettamanti, S [CISE SpA, Milan (Italy); Crudeli, R [ENEL SpA, Milan (Italy)

    1999-12-31

    CISE and ENEL are involved for years in a miniaturization creep methodology project to obtain similar non-destructive test with the same standard creep test reliability. The goal can be reached with `Small punch creep test` that collect all the requested characteristics; quasi nondestructive disk specimens extracted both on external or internal side of components, than accurately machined and tested on little and cheap apparatus. CISE has developed complete creep small punch procedure that involved peculiar test facility and correlation`s law comparable with the more diffused isostress methodology for residual life evaluation on ex-serviced high temperature plant components. The aim of this work is to obtain a simple and immediately applicable relationship useful for plant maintenance managing. More added work is need to validate the Small Punch methodology and for relationship calibration on most diffusion high temperature structural materials. First obtained results on a comparative work on ASTM A355 P12 ex-serviced pipe material are presented joint with a description of the Small Punch apparatus realized in CISE. (orig.) 6 refs.

  12. Small punch creep test: A promising methodology for high temperature plant components life evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tettamanti, S. [CISE SpA, Milan (Italy); Crudeli, R. [ENEL SpA, Milan (Italy)

    1998-12-31

    CISE and ENEL are involved for years in a miniaturization creep methodology project to obtain similar non-destructive test with the same standard creep test reliability. The goal can be reached with `Small punch creep test` that collect all the requested characteristics; quasi nondestructive disk specimens extracted both on external or internal side of components, than accurately machined and tested on little and cheap apparatus. CISE has developed complete creep small punch procedure that involved peculiar test facility and correlation`s law comparable with the more diffused isostress methodology for residual life evaluation on ex-serviced high temperature plant components. The aim of this work is to obtain a simple and immediately applicable relationship useful for plant maintenance managing. More added work is need to validate the Small Punch methodology and for relationship calibration on most diffusion high temperature structural materials. First obtained results on a comparative work on ASTM A355 P12 ex-serviced pipe material are presented joint with a description of the Small Punch apparatus realized in CISE. (orig.) 6 refs.

  13. John Punch, Scotist Holy War, and the Irish Catholic Revolutionary Tradition in the Seventeenth Century.

    Science.gov (United States)

    Campbell, Ian W

    2016-07-01

    During the 1640s, the Irish Franciscan theologian John Punch taught his theology students in Rome that war against Protestants was made just by their religion alone. Jesuits like Luis de Molina identified the holy war tradition in which Punch stood as a Scotist one, and insisted that the Scotists had confused the natural and supernatural spheres. Among Irishmen, Punch was unusual. The main Irish Catholic revolutionary tradition employed Jesuit and Thomist theory. They argued that the Stuarts had lost the right to rule Ireland for natural reasons, not supernatural ones; because the Stuarts were tyrants, not because they were Protestants.

  14. High-throughput sequencing of forensic genetic samples using punches of FTA cards with buccal swabs.

    Science.gov (United States)

    Kampmann, Marie-Louise; Buchard, Anders; Børsting, Claus; Morling, Niels

    2016-01-01

    Here, we demonstrate that punches from buccal swab samples preserved on FTA cards can be used for high-throughput DNA sequencing, also known as massively parallel sequencing (MPS). We typed 44 reference samples with the HID-Ion AmpliSeq Identity Panel using washed 1.2 mm punches from FTA cards with buccal swabs and compared the results with those obtained with DNA extracted using the EZ1 DNA Investigator Kit. Concordant profiles were obtained for all samples. Our protocol includes simple punch, wash, and PCR steps, reducing cost and hands-on time in the laboratory. Furthermore, it facilitates automation of DNA sequencing.

  15. Punching influence on magnetic properties of the stator teeth of an induction motor

    International Nuclear Information System (INIS)

    Kedous-Lebouc, A.; Cornut, B.; Perrier, J.C.; Manfe, Ph.; Chevalier, Th.

    2003-01-01

    In order to study the effects of punching of electrical steel sheets, a suitable geometrical structure able to characterize the stator teeth behavior of an induction motor is proposed and validated. The influence of the punching on a fully processed M330-65A is then characterized. A spectacular degradation of loss and B(H) curves is observed. This leads to a perceptible increase of the no-load machine current

  16. A DLC-Punch Array to Fabricate the Micro-Textured Aluminum Sheet for Boiling Heat Transfer Control

    Directory of Open Access Journals (Sweden)

    Tatsuhio Aizawa

    2018-03-01

    Full Text Available A diamond-like carbon (DLC film, coated on an SKD11 (alloy tool steel substrate, was shaped by plasma oxidation to form an assembly of DLC macro-pillars and to be used as a DLC-punch array that is micro-embossed into aluminum sheets. First, the SKD11 steel die substrate was prepared and DLC-coated to have a film thickness of 10 μm. This DLC coating worked as a punch material. The two-dimensional micro-patterns were printed onto this DLC film by maskless lithography. The unprinted DLC films were selectively removed by plasma oxidation to leave the three-dimensional DLC-punch array on the SKD11 substrate. Each DLC punch had a head of 3.5 μm × 3.5 μm and a height of 8 μm. This DLC-punch array was fixed into the cassette die set for a micro-embossing process using a table-top servo-stamper. Furthermore, through numerically controlled micro-embossing, an alignment of rectangular punches was transcribed into a micro-cavity array in the aluminum sheet. The single micro-cavity had a bottom surface of 3.2 μm × 3.2 μm and an average depth of 7.5 μm. A heat-transfer experiment in boiling water was also performed to investigate the effect of micro-cavity texture on bubbling behavior and the boiling curve.

  17. Application of Small Punch Test for Estimation of Fracture Properties of Fe-Al Alloys

    Czech Academy of Sciences Publication Activity Database

    Dobeš, Ferdinand; Milička, Karel

    2010-01-01

    Roč. 63, Sp. Iss. (2010), s. 83-86 ISSN 0018-8069. [Determination of Mechanical Properties of Materials by Small Punch and Other Miniature Testing Techniques/1./. Ostrava, 31.08.2010-02.09.2010] R&D Projects: GA ČR GA106/08/1238 Institutional research plan: CEZ:AV0Z20410507 Keywords : small punch test * ductility * iron aluminides Subject RIV: JG - Metallurgy

  18. High-throughput sequencing of forensic genetic samples using punches of FTA cards with buccal swabs

    DEFF Research Database (Denmark)

    Kampmann, Marie-Louise; Buchard, Anders; Børsting, Claus

    2016-01-01

    Here, we demonstrate that punches from buccal swab samples preserved on FTA cards can be used for high-throughput DNA sequencing, also known as massively parallel sequencing (MPS). We typed 44 reference samples with the HID-Ion AmpliSeq Identity Panel using washed 1.2 mm punches from FTA cards...

  19. Review of Punching Shear Behaviour of Flat Slabs Reinforced with FRP Bars

    Science.gov (United States)

    Mohamed, Osama A.; Khattab, Rania

    2017-10-01

    Using Fibre Reinforced Polymer (FRP) bars to reinforce two-way concrete slabs can extend the service life, reduce maintenance cost and improve-life cycle cost efficiency. FRP reinforcing bars are more environmentally friendly alternatives to traditional reinforcing steel. Shear behaviour of reinforced concrete structural members is a complex phenomenon that relies on the development of internal load-carrying mechanisms, the magnitude and combination of which is still a subject of research. Many building codes and design standards provide design formulas for estimation of punching shear capacity of FRP reinforced flat slabs. Building code formulas take into account the effects of the axial stiffness of main reinforcement bars, the ratio of the perimeter of the critical section to the slab effective depth, and the slab thickness on the punching shear capacity of two-way slabs reinforced with FRP bars or grids. The goal of this paper is to compare experimental data published in the literature to the equations offered by building codes for the estimation of punching shear capacity of concrete flat slabs reinforced with FRP bars. Emphasis in this paper is on two North American codes, namely, ACI 440.1R-15 and CSA S806-12. The experimental data covered in this paper include flat slabs reinforced with GFRP, BFRP, and CFRP bars. Both ACI 440.1R-15 and CSA S806-12 are shown to be in good agreement with test results in terms of predicting the punching shear capacity.

  20. Circumferential scouting punch biopsies to delineate surgical margin for dermatofibrosarcoma protuberans

    Directory of Open Access Journals (Sweden)

    Tsung-Mao Huang

    2012-03-01

    Full Text Available Dermatofibrosarcoma protuberans (DFSP is an uncommon soft-tissue tumor involving the dermis and subcutaneous tissue with a high local recurrence rate after standard excision. Mohs micrographic surgery offers a lower recurrence rate. However, the procedure requires multiple stages of excision with intraoperative histopathological mapping, which is time consuming and expensive. We report our experience of using circumferential scouting punch biopsy technique in five patients to determine in advance the resection margins for DFSP prior to wide excision. Multiple 4 mm punches, usually eight in number, were performed 1–2.5 cm around the palpable borders of DFSP to delineate the resection margins in five consecutive patients. Tumors were excised at a later date along the margin defined by these biopsies and the wounds were repaired with skin graft. The operation was completed in 2 hours in all cases excluding one that required frozen sections for deep margin. No recurrence was noted 2–10 years after the operations. The results suggest that circumferential scouting punch biopsies before wide excision may be an alternative method to define the resection margins for DFSP when Mohs surgery is not available.

  1. Flexural behaviour and punching shear of selfcompacting concrete ribbed slab reinforced with steel fibres

    Directory of Open Access Journals (Sweden)

    Ahmad Hazrina

    2017-01-01

    Full Text Available This paper investigates the effects of steel fibres as a replacement to the conventional reinforcement under flexural behaviour and punching shear in self-compacting (SCC ribbed slab reinforced with steel fibres. Four ribbed slabs with similar dimensions of 2.8 m length × 1.2 m width and 0.2m thickness were constructed. Two of the samples were considered as control samples (conventionally reinforced with reinforcement bars and welded mesh while another two samples were fully reinforced with 1% (80 kg/m3 volume of steel fibres incorporated to the SCC mix. For the flexural behaviour study, the ribbed slab samples were subjected to two line loads under four point bending. Meanwhile, for the punching shear analysis, the ribbed slab samples were subjected to a point load to simulate loading from the column. The analysis of the experimental results displayed that steel fibres incorporation had been found to effectively delay the first crack occurrence under both flexural and punching shear. The steel fibre replacement has been proven to be able to sustain up to 80% and 73% of the ultimate load resistance for flexural and punching shear, respectively, in comparison to conventionally reinforced ribbed slab structure. The visual observation carried out during the experiment exhibited similar failure mode for both steel fibre reinforced and control samples. This was observed for both flexural and punching shear samples. Overall, it can be concluded that the steel fibres had displayed a promising potential to effectively replace the conventional reinforcements.

  2. Analysis of potential factors influencing the relation between small punch and conventional creep test

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr; Milička, Karel; Dobeš, Ferdinand

    2010-01-01

    Roč. 63, Spp. Issue (2010), s. 50-53 ISSN 0018-8069. [International Conference "Determination of Mechanical Properties of Materials by Small Punch and Other Miniature testing Techniques" /1./. Ostrava, 31.08.2010-02.09.2010] R&D Projects: GA AV ČR(CZ) IAA200410801 Institutional research plan: CEZ:AV0Z20410507 Keywords : creep * small punch test * chromium steel Subject RIV: JG - Metallurgy

  3. Diagnostic accuracy of confocal microscopy imaging vs. punch biopsy for diagnosing and subtyping basal cell carcinoma

    NARCIS (Netherlands)

    Kadouch, D. J.; Leeflang, M. M.; Elshot, Y. S.; Longo, C.; Ulrich, M.; van der Wal, A. C.; Wolkerstorfer, A.; Bekkenk, M. W.; de Rie, M. A.

    2017-01-01

    BackgroundIn vivo reflectance confocal microscopy (RCM) is a promising non-invasive skin imaging technique that could facilitate early diagnosis of basal cell carcinoma (BCC) instead of routine punch biopsies. However, the clinical value and utility of RCM vs. a punch biopsy in diagnosing and

  4. Experimental and Computational Study of Ductile Fracture in Small Punch Tests

    Directory of Open Access Journals (Sweden)

    Betül Gülçimen Çakan

    2017-10-01

    Full Text Available A unified experimental-computational study on ductile fracture initiation and propagation during small punch testing is presented. Tests are carried out at room temperature with unnotched disks of different thicknesses where large-scale yielding prevails. In thinner specimens, the fracture occurs with severe necking under membrane tension, whereas for thicker ones a through thickness shearing mode prevails changing the crack orientation relative to the loading direction. Computational studies involve finite element simulations using a shear modified Gurson-Tvergaard-Needleman porous plasticity model with an integral-type nonlocal formulation. The predicted punch load-displacement curves and deformed profiles are in good agreement with the experimental results.

  5. Experimental and Computational Study of Ductile Fracture in Small Punch Tests.

    Science.gov (United States)

    Gülçimen Çakan, Betül; Soyarslan, Celal; Bargmann, Swantje; Hähner, Peter

    2017-10-17

    A unified experimental-computational study on ductile fracture initiation and propagation during small punch testing is presented. Tests are carried out at room temperature with unnotched disks of different thicknesses where large-scale yielding prevails. In thinner specimens, the fracture occurs with severe necking under membrane tension, whereas for thicker ones a through thickness shearing mode prevails changing the crack orientation relative to the loading direction. Computational studies involve finite element simulations using a shear modified Gurson-Tvergaard-Needleman porous plasticity model with an integral-type nonlocal formulation. The predicted punch load-displacement curves and deformed profiles are in good agreement with the experimental results.

  6. Using stamping punch force variation for the identification of changes in lubrication and wear mechanism

    Science.gov (United States)

    Voss, B. M.; Pereira, M. P.; Rolfe, B. F.; Doolan, M. C.

    2017-09-01

    The growth in use of Advanced High Strength Steels in the automotive industry for light-weighting and safety has increased the rates of tool wear in sheet metal stamping. This is an issue that adds significant costs to production in terms of manual inspection and part refinishing. To reduce these costs, a tool condition monitoring system is required and a firm understanding of process signal variation must form the foundation for any such monitoring system. Punch force is a stamping process signal that is widely collected by industrial presses and has been linked closely to part quality and tool condition, making it an ideal candidate as a tool condition monitoring signal. In this preliminary investigation, the variation of punch force due to different lubrication conditions and progressive wear are examined. Linking specific punch force signature changes to developing lubrication and wear events is valuable for die wear and stamping condition monitoring. A series of semi-industrial channel forming trials were conducted under different lubrication regimes and progressive die wear. Punch force signatures were captured for each part and Principal Component Analysis (PCA) was applied to determine the key Principal Components of the signature data sets. These Principal Components were linked to the evolution of friction conditions over the course of the stroke for the different lubrication regimes and mechanism of galling wear. As a result, variation in punch force signatures were correlated to the current mechanism of wear dominant on the formed part; either abrasion or adhesion, and to changes in lubrication mechanism. The outcomes of this study provide important insights into punch force signature variation, that will provide a foundation for future work into the development of die wear and lubrication monitoring systems for sheet metal stamping.

  7. Effect of Friction Coefficient on the Small Punch Creep Behavior of AISI 316L Stainless Steel

    International Nuclear Information System (INIS)

    Kim, Bum-Joon; Cho, Nam-Hyuck; Kim, Moon-K; Lim, Byeong-Soo

    2011-01-01

    Small punch creep testing has received attention due to the convenience of using smaller specimens than those of conventional uniaxial creep tests, which enables creep testing on developing or currently operational components. However, precedent studies have shown that it is necessary to consider friction between the punch and specimen when computing uniaxial equivalent stress from a finite element model. In this study, small punch creep behaviors of AISI 316L stainless steel, which is widely used in high temperature-high pressure machineries, have been compared for the two different ceramic balls such as Si 3 N 4 and Al 2 O 3 . The optimal range of the friction coefficient is 0.4⁓0.5 at 650°C for the best fit between experimental and simulation data of AISI 316 L stainless steel. The higher the friction coefficient, the longer the creep rupture time is. Therefore, the type of ceramic ball used must be specified for standardization of small punch creep testing.

  8. Small punch creep test in a 316 austenitic stainless steel

    Directory of Open Access Journals (Sweden)

    Saucedo-Muñoz, Maribel L.

    2015-03-01

    Full Text Available The small punch creep test was applied to evaluate the creep behavior of a 316 type austenitic stainless steel at temperatures of 650, 675 and 700 °C. The small punch test was carried out using a creep tester with a specimen size of 10×10×0.3 mm at 650, 675 and 700 °C using loads from 199 to 512 N. The small punch creep curves show the three stages found in the creep curves of the conventional uniaxial test. The conventional creep relationships which involve parameters such as creep rate, stress, time to rupture and temperature were followed with the corresponding parameters of small punch creep test and they permitted to explain the creep behavior in this steel. The mechanism and activation energy of the deformation process were the grain boundary sliding and diffusion, respectively, during creep which caused the intergranular fracture in the tested specimens.El ensayo de termofluencia por indentación se utilizó para evaluar el comportamiento a la termofluencia en un acero inoxidable austenítico 316. Este ensayo se realizó en una máquina de indentación con muestras de 10×10×0,3 mm a temperaturas de 650, 675 y 700 °C con cargas de 199 a 512 N. Las curvas de termofluencia del ensayo mostraron las tres etapas características observadas en el ensayo convencional de tensión. Asimismo, las principales relaciones de termofluencia entre parámetros como velocidad de termofluencia, esfuerzo, tiempo de ruptura y temperatura se observaron en los parámetros correspondientes al ensayo de indentación, lo que permitió caracterizar el comportamiento de termofluencia en este acero. El mecanismo y la energía de activación del proceso de deformación en la termofluencia corresponden al deslizamiento de los límites de grano y la difusión a través de los mismos, respectivamente, lo cual causó la fractura intergranular en las muestras ensayadas.

  9. Effects of laser power density and initial grain size in laser shock punching of pure copper foil

    Science.gov (United States)

    Zheng, Chao; Zhang, Xiu; Zhang, Yiliang; Ji, Zhong; Luan, Yiguo; Song, Libin

    2018-06-01

    The effects of laser power density and initial grain size on forming quality of holes in laser shock punching process were investigated in the present study. Three different initial grain sizes as well as three levels of laser power densities were provided, and then laser shock punching experiments of T2 copper foil were conducted. Based upon the experimental results, the characteristics of shape accuracy, fracture surface morphology and microstructures of punched holes were examined. It is revealed that the initial grain size has a noticeable effect on forming quality of holes punched by laser shock. The shape accuracy of punched holes degrades with the increase of grain size. As the laser power density is enhanced, the shape accuracy can be improved except for the case in which the ratio of foil thickness to initial grain size is approximately equal to 1. Compared with the fracture surface morphology in the quasistatic loading conditions, the fracture surface after laser shock can be divided into three zones including rollover, shearing and burr. The distribution of the above three zones strongly relates with the initial grain size. When the laser power density is enhanced, the shearing depth is not increased, but even diminishes in some cases. There is no obvious change of microstructures with the enhancement of laser power density. However, while the initial grain size is close to the foil thickness, single-crystal shear deformation may occur, suggesting that the ratio of foil thickness to initial grain size has an important impact on deformation behavior of metal foil in laser shock punching process.

  10. "One can't shake off the women": images of sport and gender in Punch, 1901-10.

    Science.gov (United States)

    Constanzo, Marilyn

    2002-01-01

    Examining the manner in which the popular press portrayed middle-class Edwardian women's activity in sport provides insight into the social liberation of English women. The popular middle-class British journal Punch included thousands of images of sportswomen. Despite the misogynistic satirizing of inept women, Punch's cartoons and articles depict distinct changes in women's behavior and social expectations that are linked to their increasing involvement in sport. By engaging in sport, women unconsciously challenged and permanently altered the pervasive middle-class Victorian ideology. The contents of Punch suggests that middle-class women's participation in sport, though perhaps begun in a conservative manner, completely altered and expanded their social role and changed the traditional image of womanhood.

  11. Feasibility of attaining uniform grain structure and enhanced ductility in aluminum alloy by employing a beveled punch in equal-channel angular pressing

    Energy Technology Data Exchange (ETDEWEB)

    Nejadseyfi, Omid, E-mail: o.nejadseyfi@gmail.com [Advanced Materials and Nanotechnology Research Lab, Department of Mechanical Engineering, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Shokuhfar, Ali [Advanced Materials and Nanotechnology Research Lab, Department of Mechanical Engineering, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Sadeghi, Seyedali [Department of Mechanical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2016-01-10

    The advantage of using a beveled-edge punch in equal-channel angular pressing is investigated. Lambda angle (λ), the clockwise angle between the theoretical shear plane and punch/billet interface, is used to demonstrate how the punch tip is inclined. Transmission electron microscope is used to assess the microstructure of the samples processed using a beveled-edge punch. In addition, tensile tests at elevated temperature are performed. The results show that using a beveled-edge punch (λ=90°) in the process leads to formation of uniform subgrain structure and increases the tensile ductility for the samples at elevated temperature. Additionally, finite element simulations are performed to study the correlation between measured properties and mechanism of material deformation by employing a beveled-edge punch. Numerical simulations confirm the irregular deformation in case of λ=0° and uniform strain distribution for λ=90°, which were the main reasons of variation in mechanical properties.

  12. HOW BOXERS DECIDE TO PUNCH A TARGET: EMERGENT BEHAVIOUR IN NONLINEAR DYNAMICAL MOVEMENT SYSTEMS

    Directory of Open Access Journals (Sweden)

    Robert Hristovski

    2006-07-01

    Full Text Available Previous research has shown how dynamical systems theory provides a relevant framework for investigating decision-making behavior in sport. The aim of this study was to adopt concepts and tools from nonlinear dynamics in examining effects of boxer-target distance and perceived punching efficiency on emergent decision-making during a typical practice task in boxing. Results revealed the existence of critical values of scaled distances between boxers and targets for first time appearance and disappearance of a diverse range of boxing actions including jabs, hooks and uppercuts. Reasons for the diversity of actions were twofold: i abrupt (qualitative changes in the number of the possible punches, i.e. motor solutions to the hitting task; and ii, fine modification of the probabilities of selecting specific striking patterns. Boxers were able to exploit the emerging perception of strikeability, leading to a changing diversity of selected actions and a cascade of abrupt changes in the perceptual-motor work space of the task. Perceived efficiency of a punching action by the participants also changed as a function of the scaled distance to a target and was correlated with the probability of occurrence of specific boxing actions. Accordingly, scaled distance-dependent perceived efficiency seems an important perceptual constraint in the training task of punching a heavy bag in boxers

  13. Autologous Fat Injection for Augmented Mammoplasty

    International Nuclear Information System (INIS)

    Yoon, Eul Sik; Seo, Bo Kyoung; Yi, Ann; Cho, Kyu Ran

    2008-01-01

    Autologous fat injection is one of the methods utilized for augmented mammoplasty methods. In this surgical procedure, the fat for transfer is obtained from the donor site of the patient's own body by liposuction and the fat is then injected into the breast. We report here cases of three patients who underwent autologous fat injection. Two of the patients had palpable masses that were present after surgery. The serial imaging findings and surgical method of autologous fat transfer are demonstrated

  14. Recent developments in small punch testing: Applications at elevated temperatures

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr

    2016-01-01

    Roč. 86, DEC (2016), s. 25-33 ISSN 0167-8442 R&D Projects: GA MŠk(CZ) LQ1601 Institutional support: RVO:68081723 Keywords : Small punch test * Creep rupture * Stress relaxation Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.659, year: 2016

  15. Numerical investigation by finite element simulation of the bail punch test: application to tempered martensitic steels

    International Nuclear Information System (INIS)

    Campitelli, E.; Spatig, P.; Bertsch, J.

    2007-01-01

    Full text of publication follows: Over the years, the small ball punch test technique has been used to evaluate conventional tensile properties of a variety of materials. The development and use of this type of small specimen techniques is indispensable for an efficient use of the limited irradiation volume of the future fusion material intense neutron source. Up to now, empirical correlations between features of the load-displacement curves of the ball punch test and the mechanical properties, such as the yield stress or the ultimate tensile stress, are established on materials in the unirradiated condition. These correlations are believed to be applicable to irradiated materials and they have been very often used to estimate the irradiation hardening. However, it is well known that the overall constitutive behavior of the materials is generally affected by neutron irradiation. Therefore, there is a need to quantify the effect of the constitutive behavior on the correlations. In this paper, we employ a 3D non-linear finite element model for the ball punch test to address these effects of the irradiation-induced changes on the ball punch test curve. We apply first the model on the tempered martensitic steel EUROFER97 in the unirradiated condition with variations in the post-yield behavior, either in the low strain domain ( 10%). The effects on the ball punch test load deflection curve are outlined. Second, we study the effects of the irradiation hardening on the same constitutive behaviors as those used for the unirradiated condition. We show that that the usual correlations must be considered with great care on irradiated materials since strong variation on the strain-hardening may lead to erroneous estimation of the irradiation hardening. We also propose a novel approach to calibrate the yield stress to features of the ball punch test curve that decreases the uncertainty related to the post-yield behavior and that, as a consequence, makes the technique more

  16. Cracking the code: a decode strategy for the international business machines punch cards of Korean war soldiers.

    Science.gov (United States)

    Mitsunaga, Erin M

    2006-05-01

    During the Korean War, International Business Machines (IBM) punch cards were created for every individual involved in military combat. Each card contained all pertinent personal information about the individual and was utilized to keep track of all soldiers involved. However, at present, all of the information known about these punch cards reveals only their format and their significance; there is little to no information on how these cards were created or how to interpret the information contained without the aid of the computer system used during the war. Today, it is believed there is no one available to explain this computerized system, nor do the original computers exist. This decode strategy is the result of an attempt to decipher the information on these cards through the use of all available medical and dental records for each individual examined. By cross-referencing the relevant personal information with the known format of the cards, a basic guess-and-check method was utilized. After examining hundreds of IBM punch cards, however, it has become clear that the punch card method of recording information was not infallible. In some cases, there are gaps of information on cards where there are data recorded on personal records; in others, information is punched incorrectly onto the cards, perhaps as the result of a transcription error. Taken all together, it is clear that the information contained on each individual's card should be taken solely as another form of personal documentation.

  17. Fracture-based correlation of uniaxial and small punch creep data

    Czech Academy of Sciences Publication Activity Database

    Dobeš, Ferdinand; Dymáček, Petr

    2016-01-01

    Roč. 86, DEC (2016), s. 34-38 ISSN 0167-8442 R&D Projects: GA MŠk LM2015069; GA MŠk(CZ) LQ1601 Institutional support: RVO:68081723 Keywords : Creep * Small punch test * Chromium steel Subject RIV: JG - Metallurgy Impact factor: 2.659, year: 2016

  18. The BaBar Mini

    International Nuclear Information System (INIS)

    Brown, David N.

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  19. The BaBar mini

    International Nuclear Information System (INIS)

    Brown, David N.; BaBar Collaboration

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  20. Inflammatory effects of autologous, genetically modified autologous, allogeneic, and xenogeneic mesenchymal stem cells after intra-articular injection in horses.

    Science.gov (United States)

    Pigott, J H; Ishihara, A; Wellman, M L; Russell, D S; Bertone, A L

    2013-01-01

    To compare the clinical and inflammatory joint responses to intra-articular injection of bone marrow-derived mesenchymal stem cells (MSC) including autologous, genetically modified autologous, allogeneic, or xenogeneic cells in horses. Six five-year-old Thoroughbred mares had one fetlock joint injected with Gey's balanced salt solution as the vehicle control. Each fetlock joint of each horse was subsequently injected with 15 million MSC from the described MSC groups, and were assessed for 28 days for clinical and inflammatory parameters representing synovitis, joint swelling, and pain. There were not any significant differences between autologous and genetically modified autologous MSC for synovial fluid total nucleated cell count, total protein, interleukin (IL)-6, IL-10, fetlock circumference, oedema score, pain-free range-of-motion, and soluble gene products that were detected for at least two days. Allogeneic and xenogeneic MSC produced a greater increase in peak of inflammation at 24 hours than either autologous MSC group. Genetically engineered MSC can act as vehicles to deliver gene products to the joint; further investigation into the therapeutic potential of this cell therapy is warranted. Intra-articular MSC injection resulted in a moderate acute inflammatory joint response that was greater for allogeneic and xenogeneic MSC than autologous MSC. Clinical management of this response may minimize this effect.

  1. Using Teamcenter engineering software for a successive punching tool lifecycle management

    Science.gov (United States)

    Blaga, F.; Pele, A.-V.; Stǎnǎşel, I.; Buidoş, T.; Hule, V.

    2015-11-01

    The paper presents studies and researches results of the implementation of Teamcenter (TC) integrated management of a product lifecycle, in a virtual enterprise. The results are able to be implemented also in a real enterprise. The product was considered a successive punching and cutting tool, designed to materialize a metal sheet part. The paper defines the technical documentation flow (flow of information) in the process of constructive computer aided design of the tool. After the design phase is completed a list of parts is generated containing standard or manufactured components (BOM, Bill of Materials). The BOM may be exported to MS Excel (.xls) format and can be transferred to other departments of the company in order to supply the necessary materials and resources to achieve the final product. This paper describes the procedure to modify or change certain dimensions of sheet metal part obtained by punching. After 3D and 2D design, the digital prototype of punching tool moves to following lifecycle phase of the manufacturing process. For each operation of the technological process the corresponding phases are described in detail. Teamcenter enables to describe manufacturing company structure, underlying workstations that carry out various operations of manufacturing process. The paper revealed that the implementation of Teamcenter PDM in a company, improves efficiency of managing product information, eliminating time working with search, verification and correction of documentation, while ensuring the uniqueness and completeness of the product data.

  2. Intraurethral Injection of Autologous Minced Skeletal Muscle

    DEFF Research Database (Denmark)

    Gräs, Søren; Klarskov, Niels; Lose, Gunnar

    2014-01-01

    noted. CONCLUSIONS: Intraurethral injection of minced autologous muscle tissue is a simple surgical procedure that appears safe and moderately effective in women with uncomplicated stress urinary incontinence. It compares well to a more complicated regenerative strategy using in vitro expanded muscle......PURPOSE: Intraurethral injection of in vitro expanded autologous skeletal muscle derived cells is a new regenerative therapy for stress urinary incontinence. We examined the efficacy and safety of a simpler alternative strategy using freshly harvested, minced autologous skeletal muscle tissue...... with its inherent content of regenerative cells. MATERIALS AND METHODS: A total of 20 and 15 women with uncomplicated and complicated stress urinary incontinence, respectively, received intraurethral injections of minced autologous skeletal muscle tissue and were followed for 1 year. Efficacy was assessed...

  3. Interaction between a punch and an arbitrary crack or inclusion in a transversely isotropic half-space

    Science.gov (United States)

    Fabrikant, I.; Karapetian, E.; Kalinin, S. V.

    2018-02-01

    We consider the problem of an arbitrary shaped rigid punch pressed against the boundary of a transversely isotropic half-space and interacting with an arbitrary flat crack or inclusion, located in the plane parallel to the boundary. The set of governing integral equations is derived for the most general conditions, namely the presence of both normal and tangential stresses under the punch, as well as general loading of the crack faces. In order to verify correctness of the derivations, two different methods were used to obtain governing integral equations: generalized method of images and utilization of the reciprocal theorem. Both methods gave the same results. Axisymmetric coaxial case of interaction between a rigid inclusion and a flat circular punch both centered along the z-axis is considered as an illustrative example. Most of the final results are presented in terms of elementary functions.

  4. Contact Problem for an Elastic Layer on an Elastic Half Plane Loaded by Means of Three Rigid Flat Punches

    Directory of Open Access Journals (Sweden)

    T. S. Ozsahin

    2013-01-01

    Full Text Available The frictionless contact problem for an elastic layer resting on an elastic half plane is considered. The problem is solved by using the theory of elasticity and integral transformation technique. The compressive loads P and Q (per unit thickness in direction are applied to the layer through three rigid flat punches. The elastic layer is also subjected to uniform vertical body force due to effect of gravity. The contact along the interface between elastic layer and half plane is continuous, if the value of the load factor, λ, is less than a critical value, . In this case, initial separation loads, and initial separation points, are determined. Also the required distance between the punches to avoid any separation between the punches and the elastic layer is studied and the limit distance between punches that ends interaction of punches is investigated for various dimensionless quantities. However, if tensile tractions are not allowed on the interface, for the layer separates from the interface along a certain finite region. Numerical results for distance determining the separation area, vertical displacement in the separation zone, contact stress distribution along the interface between elastic layer and half plane are given for this discontinuous contact case.

  5. Performance testing of a semi-automatic card punch system, using direct STR profiling of DNA from blood samples on FTA™ cards.

    Science.gov (United States)

    Ogden, Samantha J; Horton, Jeffrey K; Stubbs, Simon L; Tatnell, Peter J

    2015-01-01

    The 1.2 mm Electric Coring Tool (e-Core™) was developed to increase the throughput of FTA(™) sample collection cards used during forensic workflows and is similar to a 1.2 mm Harris manual micro-punch for sampling dried blood spots. Direct short tandem repeat (STR) DNA profiling was used to compare samples taken by the e-Core tool with those taken by the manual micro-punch. The performance of the e-Core device was evaluated using a commercially available PowerPlex™ 18D STR System. In addition, an analysis was performed that investigated the potential carryover of DNA via the e-Core punch from one FTA disc to another. This contamination study was carried out using Applied Biosystems AmpflSTR™ Identifiler™ Direct PCR Amplification kits. The e-Core instrument does not contaminate FTA discs when a cleaning punch is used following excision of discs containing samples and generates STR profiles that are comparable to those generated by the manual micro-punch. © 2014 American Academy of Forensic Sciences.

  6. A possible mechanism for electron-bombardment-induced loop punching in helium-implanted materials

    International Nuclear Information System (INIS)

    Donnelly, S.E.

    1983-01-01

    The recently proposed mechanism for the punching of dislocation loops by overpressurized helium bubbles in molybdenum is studied quantitatively. According to this mechanism, under the electron beam of the transmission microscope, He atoms are excited or ionized and the resulting excited species (excited He atoms and free electrons) are responsible for the pressure rise in the gas beyond the threshold for loop punching. In the model, the pressure increase is attributed to a reduction of the effective volume accessible to the gas due to the formation of a cavity around each excited species. The radius of this cavity is evaluated and, also, the excited fraction required to reach the threshold is discussed in terms of excitation life times. (author)

  7. A Semiotics of Cartoons in Two Nigerian Newspapers: The Punch ...

    African Journals Online (AJOL)

    The paper explores the semiotics of cartoons using selected samples from The punch and The Guardian, newspapers based in Nigeria. It seeks to bridge the gap between semiotics and the act of cartooning. It also attempts to show the relationship between the cartoons and the semiotic resources employed. It analyses how ...

  8. Investigating the effect of tablet thickness and punch curvature on density distribution using finite elements method.

    Science.gov (United States)

    Diarra, Harona; Mazel, Vincent; Busignies, Virginie; Tchoreloff, Pierre

    2015-09-30

    Finite elements method was used to study the influence of tablet thickness and punch curvature on the density distribution inside convex faced (CF) tablets. The modeling of the process was conducted on 2 pharmaceutical excipients (anhydrous calcium phosphate and microcrystalline cellulose) by using Drucker-Prager Cap model in Abaqus(®) software. The parameters of the model were obtained from experimental tests. Several punch shapes based on industrial standards were used. A flat-faced (FF) punch and 3 convex faced (CF) punches (8R11, 8R8 and 8R6) with a diameter of 8mm were chosen. Different tablet thicknesses were studied at a constant compression force. The simulation of the compaction of CF tablets with increasing thicknesses showed an important change on the density distribution inside the tablet. For smaller thicknesses, low density zones are located toward the center. The density is not uniform inside CF tablets and the center of the 2 faces appears with low density whereas the distribution inside FF tablets is almost independent of the tablet thickness. These results showed that FF and CF tablets, even obtained at the same compression force, do not have the same density at the center of the compact. As a consequence differences in tensile strength, as measured by diametral compression, are expected. This was confirmed by experimental tests. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Effect of mid-thickness rebar mesh on the behavior and punching shear strength of interior slab–column connection

    Directory of Open Access Journals (Sweden)

    Ahmed Ibrahim

    2016-12-01

    The obtained results indicate that, the proposed shear reinforcement system has a positive effect in the enhancement of both the punching shear capacity and the strain energy of interior slab–column connection of both normal and high strength concrete. The general finite element software ANSYS can be used successfully to simulate the punching shear behavior of reinforced concrete flat plates.

  10. Studying the sensor response in the punch-through-protection region

    CERN Document Server

    Poley, Anne-luise; The ATLAS collaboration

    2017-01-01

    For the Phase-II Upgrade of the ATLAS detector, a new, all-silicon tracker will be constructed in order to cope with the increased track density and radiation level of the High Luminosity Large Hadron Collider. While silicon strip sensors are designed to minimise the fraction of dead material and maximise the active area of a sensor, concessions must be made to the requirements of operating a sensor in a particle physics detector. Sensor geometry features like the punch-through protection deviate from the standard sensor architecture and thereby affect the charge collection in that area. In order to study the signal collection of silicon strip sensors over their punch-through-protection area, ATLAS silicon strip sensors were scanned with a micro-focused X-ray beam at the Diamond Light Source. Due to the highly focused X-ray beam (2 × 3 µm) and the short average path length of an electron after interaction with an X-ray photon (≤ 2 μm), local signal collection in different sensor areas can be studied with...

  11. Repetitive forging (RF) using inclined punches as a new bulk severe plastic deformation method

    Energy Technology Data Exchange (ETDEWEB)

    Babaei, A. [Department of Mechanical Engineering, University College of Engineering, University of Tehran, Tehran 11155-4563 (Iran, Islamic Republic of); Faraji, G., E-mail: ghfaraji@ut.ac.ir [Department of Mechanical Engineering, University College of Engineering, University of Tehran, Tehran 11155-4563 (Iran, Islamic Republic of); Department of Engineering Design and Manufacture, University of Malaya, 50603 Kuala Lumpur (Malaysia); Mashhadi, M.M. [Department of Mechanical Engineering, University College of Engineering, University of Tehran, Tehran 11155-4563 (Iran, Islamic Republic of); Hamdi, M. [Department of Engineering Design and Manufacture, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2012-12-15

    A new bulk severe plastic deformation method based on repetitive forging (RF) using inclined punches is proposed. This process consists of two half cycles. In the first half cycle, a square cross section deforms to parallelogram by forging with two inclined punches, and the parallelogram cross section is forged back to square using two flat punches in the second half cycle. This method was applied to commercially pure copper and significant grain refinement was achieved after four passes of RF. The results showed that significant improvement in the mechanical properties was obtained. Notable increase of yield and ultimate strengths corresponding to 358 MPa and 381 MPa after four passes of RF from the initial values of 121 MPa and 230.5 MPa is detectable. Microhardness increases to about 100 Hv after four passes of RF from the initial value of 53 Hv. Finite element (FE) results illustrate that RF is able to impose extremely high plastic strains to the materials. In the RF process, the processed samples have the same dimensions and geometry as those of the initial sample without any waste material and there is no need for back pressure.

  12. Long-term results of 2-mm punch grafting in patients with vitiligo vulgaris and segmental vitiligo: effect of disease activity

    NARCIS (Netherlands)

    Fongers, A.; Wolkerstorfer, A.; Nieuweboer-Krobotova, L.; Krawczyk, P.; Tóth, G. G.; van der Veen, J. P. W.

    2009-01-01

    Background Punch grafting is a simple and frequently used technique for the treatment of stable vitiligo, resistant to medical therapy. However, studies reporting long-term results are exceptional. Objectives To evaluate the long-term results of 2-mm punch grafting in patients with vitiligo vulgaris

  13. Long-term results of 2-mm punch grafting in patients with vitiligo vulgaris and segmental vitiligo : effect of disease activity

    NARCIS (Netherlands)

    Fongers, A.; Wolkerstorfer, A.; Nieuweboer-Krobotova, L.; Krawczyk, P.; Toth, G. G.; van der Veen, J. P. W.

    Background Punch grafting is a simple and frequently used technique for the treatment of stable vitiligo, resistant to medical therapy. However, studies reporting long-term results are exceptional. Objectives To evaluate the long-term results of 2-mm punch grafting in patients with vitiligo vulgaris

  14. Long-term results of 2-mm punch grafting in patients with vitiligo vulgaris and segmental vitiligo : effect of disease activity

    NARCIS (Netherlands)

    Fongers, A.; Wolkerstorfer, A.; Nieuweboer-Krobotova, L.; Krawczyk, P.; Toth, G. G.; van der Veen, J. P. W.

    2009-01-01

    Background Punch grafting is a simple and frequently used technique for the treatment of stable vitiligo, resistant to medical therapy. However, studies reporting long-term results are exceptional. Objectives To evaluate the long-term results of 2-mm punch grafting in patients with vitiligo vulgaris

  15. Adjuvant therapeutic vaccination in patients with non-small cell lung cancer made lymphopenic and reconstituted with autologous PBMC: first clinical experience and evidence of an immune response

    Directory of Open Access Journals (Sweden)

    Schendel Dolores J

    2007-09-01

    reactions. One patient developed positive DTH skin tests so far. Immunohistochemical assessment of punch biopsies taken at the local vaccine site reaction revealed a dense lymphocyte infiltrate. Further immunohistochemical differentiation showed that CD1a+ cells had been attracted to the vaccine site as well as predominantly CD4+ lymphocytes. The 3-day combination chemotherapy consisting of cyclophosphamide and fludarabine induced a profound lymphopenia in all patients. Sequential FACS analysis revealed that different T cell subsets (CD4, CD8, CD4CD25 as well as granulocytes, B cells and NK cells were significantly reduced. Here, we report on clinical safety and feasibility of this vaccination approach during lymphoid recovery and demonstrate a patient example. Conclusion Thus far, all vaccines were well tolerated. The overall trial design seems safe and feasible. Vaccine site reactions associated with infusion of GM-CSF via mini-pump are consistent with the postulated mechanism of action. More detailed immune-monitoring is required to evaluate a potential systemic immune response. Further studies to exploit homeostasis-driven T cell proliferation for the induction of a specific anti-tumor immune response in this clinical setting are warranted.

  16. Cone penetrometer tests and HydroPunch sampling: A screening technique for plume definition

    International Nuclear Information System (INIS)

    Smolley, M.; Kappmeyer, J.C.

    1991-01-01

    Cone penetrometer tests and HydroPunch sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of the these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program

  17. Experimental and numerical analysis of micromechanical damage in the punching process for High-Strength Low-Alloy steels

    OpenAIRE

    ACHOURI, Mohamed; GERMAIN, Guénaël; DAL SANTO, Philippe; SAIDANE, Delphine

    2014-01-01

    Sequential sheet metal forming processes can result in the accumulation of work hardening and damage effects in the workpiece material. The mechanical strength of the final component depends on the “evolution” of these two characteristics in the different production steps. The punching process, which is usually in the beginning of the production chain, has an important impact on the stress, strain and damage states in the punched zones. It is essential that the influence of these mechanical f...

  18. Newborn screening blood spot analysis in the UK: influence of spot size, punch location and haematocrit.

    Science.gov (United States)

    Lawson, A J; Bernstone, L; Hall, S K

    2016-03-01

    In dried blood spot analysis, punch location and variations in applied sample volume and haematocrit can produce different measured concentrations of analytes. We investigated the magnitude of these effects in newborn screening in the UK. Heparinized blood spiked with thyroid stimulating hormone (TSH), phenylalanine, tyrosine, leucine, methionine, octanoyl carnitine (C8), and immunoreactive trypsinogen (IRT) was spotted onto filter paper: (i) at a constant haematocrit of 50% at various volumes, and (ii) at a range of haematocrits using a constant volume. Subpunches (3.2 mm) of the dried blood spots were then analysed. Compared with a central punch from a 50 µL blood spot with 50% haematocrit, 10 µL spots can have significantly lower measured concentrations of all analytes, with decreases of 15% or more observed for leucine, methionine, phenylalanine, and tyrosine. Punching at the edge of a spot can increase measured concentrations up to 35%. Higher haematocrit decreased measured TSH and C8 yet increased amino acids and IRT by 15% compared with 50% haematocrit. Lower haematocrits had the opposite effect, but only with higher concentrations of some analytes. Differences in blood spot size, haematocrit and punch location substantially affect measured concentrations for analytes used in the UK newborn screening programme, and this could affect false positive and negative rates. To minimize analytical bias, these variables should be controlled or adjusted for where possible. © The Author(s) 2015.

  19. Usage of prestressed vertical bolts for retrofitting flat slabs damaged due to punching shear

    Directory of Open Access Journals (Sweden)

    Hamed S. Askar

    2015-09-01

    An experimental investigation with the objective of retrofitting flat slabs damaged due to punching shear using prestressed vertical bolts is presented in this paper. The parameters examined in this study are vertical prestressed bolts with different ratios within the slab thickness, slab thickness and central column size. Through the experimental tests the load carrying capacity, deformation characteristics and the cracking behavior have been investigated. A comparison between the behavior of retrofitted slabs and their references showed that the proposed system of repair is effective and could be used in practice. A comparison between the experimental results and calculated punching failure load based on the formulas adopted by different codes, showed a reasonable agreement.

  20. Characterization of Rubbers from Spherical Punch - Plate Indentation Tests

    Directory of Open Access Journals (Sweden)

    Florina Carmen Ciornei

    2016-12-01

    Full Text Available Rubber plates with different compositions and hardness were tested by continuous indentation, using a spherical punch and hysteretic phenomenon was evidenced. The experimental data interpolation with polynomial functions is accurate and permits estimation of the lost work during loading cycles. The interpolation by power law functions is more convenient by using less parameters and having a form accepted in literature. From the rubbers tested, two were considered to present good damping properties.

  1. The influence of punching process on residual stress and magnetic domain structure of non-oriented silicon steel

    International Nuclear Information System (INIS)

    Cao, Hongzhi; Hao, Linpo; Yi, Jingwen; Zhang, Xianglin; Luo, Zhonghan; Chen, Shenglin; Li, Rongfeng

    2016-01-01

    The main purpose of this paper is to investigate the influence of punching process on residual stress and magnetic domain structure. The residual stress in non-oriented silicon steel after punching process was measured by nanoindentation. The maximum depth was kept constant as 300 nm during nanoindentation. The material around indentation region exhibited no significant pile-up deformation. The calculation of residual stress was based on the Suresh theoretical model. Our experimental results show that residual compressive stress was generated around the sheared edge after punching. The width of residual stress affected zone by punching was around 0.4–0.5 mm. After annealing treatment, the residual stress was significantly decreased. Magnetic domain structure was observed according to the Bitter method. The un-annealed sample exhibited complicated domain patterns, and the widths of the magnetic domains varied between 3 µm and 8 µm. Most of the domain patterns of the annealed sample were 180°-domains and 90°-domains, and the widths of the domains decreased to 1–3 µm. - Highlights: • The residual stress distribution on sheared edge was measured. • The residual compressive stress was generated around the sheared edge. • The width of residual stress affected zone was about 0.4–0.5 mm. • The shape and width of the domain structure would be changed by annealing.

  2. Small Punch Tests applied to the nuclear industry

    International Nuclear Information System (INIS)

    Moreno, M.; Gongora, P.; Bertolino, G; Yawny, A.

    2012-01-01

    The interest on miniaturized specimen techniques for the characterization of the mechanical behavior of materials was strongly motivated in the early eighties by the different programs associated with the development of fusion reactor technology. The importance of such developments is obvious in the case of the nuclear industry where the limited space available, the presence of fluence gradients in large specimens, the concern about gamma heating and dose to personnel in post-irradiation testing have all been motivations for reducing specimen size. Testing of miniature specimen includes a wide spectrum of techniques such as tensile, instrumented micro-hardness, small punch, bend, fracture, impact and fatigue. Small Punch Testing (SPT) techniques use a spherical penetrator which deforms to failure a miniature disc shaped flat specimen (typically, 3-10 mm in diameter and 0.25-0.50 mm in thickness) supported on its outer rim. Analysis of load-displacement data recorded along the test is performed for the determination of the property of interest. The present work focuses on the characterization of the elastoplastic response of pure Al, ADN 420 structural steel and AISI 304L using SPT and its correlation with the associated standard uniaxial testing behavior. In addition, the sensitivity of the technique to the specific material under study and to different experimental parameters, i.e. specimen diameter and thickness, clearance or clamping force and friction between disc and dies have been assessed both experimentally and by performing simulations using the finite element method (author)

  3. Chimeric autologous/allogeneic constructs for skin regeneration.

    Science.gov (United States)

    Rasmussen, Cathy Ann; Tam, Joshua; Steiglitz, Barry M; Bauer, Rebecca L; Peters, Noel R; Wang, Ying; Anderson, R Rox; Allen-Hoffmann, B Lynn

    2014-08-01

    The ideal treatment for severe cutaneous injuries would eliminate the need for autografts and promote fully functional, aesthetically pleasing autologous skin regeneration. NIKS progenitor cell-based skin tissues have been developed to promote healing by providing barrier function and delivering wound healing factors. Independently, a device has recently been created to "copy" skin by harvesting full-thickness microscopic tissue columns (MTCs) in lieu of autografts traditionally harvested as sheets. We evaluated the feasibility of combining these two technologies by embedding MTCs in NIKS-based skin tissues to generate chimeric autologous/allogeneic constructs. Chimeric constructs have the potential to provide immediate wound coverage, eliminate painful donor site wounds, and promote restoration of a pigmented skin tissue possessing hair follicles, sweat glands, and sebaceous glands. After MTC insertion, chimeric constructs and controls were reintroduced into air-interface culture and maintained in vitro for several weeks. Tissue viability, proliferative capacity, and morphology were evaluated after long-term culture. Our results confirmed successful MTC insertion and integration, and demonstrated the feasibility of generating chimeric autologous/allogeneic constructs that preserved the viability, proliferative capacity, and structure of autologous pigmented skin. These feasibility studies established the proof-of-principle necessary to further develop chimeric autologous/allogeneic constructs for the treatment of complex skin defects. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  4. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI).

    Science.gov (United States)

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-05-22

    There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen's kappa and "observed agreement". There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and "observed agreement" was above 88%. The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language.

  5. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    Science.gov (United States)

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen’s kappa and “observed agreement”. Results There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and “observed agreement” was above 88%. Conclusion The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language. PMID:24886297

  6. Cost Optimization on Energy Consumption of Punching Machine Based on Green Manufacturing Method at PT Buana Intan Gemilang

    OpenAIRE

    Prillia Ayudia; Rachmat Haris; Mulyana Tatang

    2017-01-01

    PT Buana Intan Gemilang is a company engaged in textile industry. The curtain textile production need punching machine to control the fabric process. The operator still works manually so it takes high cost of electrical energy consumption. So to solve the problem can implement green manufacturing on punching machine. The method include firstly to identify the color by classifying the company into the black, brown, gray or green color categories using questionnaire. Secondly is improvement are...

  7. Cost Optimization on Energy Consumption of Punching Machine Based on Green Manufacturing Method at PT Buana Intan Gemilang

    Directory of Open Access Journals (Sweden)

    Prillia Ayudia

    2017-01-01

    Full Text Available PT Buana Intan Gemilang is a company engaged in textile industry. The curtain textile production need punching machine to control the fabric process. The operator still works manually so it takes high cost of electrical energy consumption. So to solve the problem can implement green manufacturing on punching machine. The method include firstly to identify the color by classifying the company into the black, brown, gray or green color categories using questionnaire. Secondly is improvement area to be optimized and analyzed. Improvement plan at this stage that is focusing on energy area and technology. Thirdly is process applies by modifying the technology through implementing automation system on the punching machine so that there is an increase of green level on the process machine. The result obtained after implement the method can save cost on electrical energy consumption in the amount of Rp 1.068.159/day.

  8. Predeposit autologous blood transfusion: Do we require to promote it?

    Directory of Open Access Journals (Sweden)

    Gurjit Singh

    2015-01-01

    Full Text Available Introduction: Safest blood a patient can receive is his own. Quest for safe blood transfusion has remained of prime concern. To meet this aspiration, various forms of autologous blood transfusions can be practiced. It is especially suitable for patients with rare blood groups and religious sects such as Jehovah′s witness autologous transfusion is extremely safe. Cross matching is not required; iso-immunization to a foreign body is excluded. Fear of transfusion transmissible disease can be ignored. Therefore, autologous blood transfusion is required to be revisited. Materials and Methods: This is a prospective study carried out at Padmashree Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune between July 2010 and May 2012. Study comprised of 100 patients divided into two groups, autologous and homologous. Benefits of autologous transfusion were studied. Results: There was no significant change in hematocrit and blood parameters after blood donation. That is mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration (P < 0.001 after blood donation. Only one complication of vasovagal syncope was observed at the time of blood donation. Conclusion: Autologous blood transfusion is safe. Easy alternative to be practiced in elective surgeries, especially in patients with rare blood group or believers of Jehovah′s witness faith. It helps to reduce the shortfall in national blood inventory. Autologous blood donation should be practiced whenever possible.

  9. The development of a tensile-shear punch correlation for yield properties of model austenitic alloys

    Energy Technology Data Exchange (ETDEWEB)

    Hankin, G.L.; Faulkner, R.G. [Loughborough Univ. (United Kingdom); Hamilton, M.L.; Garner, F.A. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-08-01

    The effective shear yield and maximum strengths of a set of neutron-irradiated, isotopically tailored austentic alloys were evaluated using the shear punch test. The dependence on composition and neutron dose showed the same trends as were observed in the corresponding miniature tensile specimen study conducted earlier. A single tensile-shear punch correlation was developed for the three alloys in which the maximum shear stress or Tresca criterion was successfully applied to predict the slope. The correlation will predict the tensile yield strength of the three different austenitic alloys tested to within {+-}53 MPa. The accuracy of the correlation improves with increasing material strength, to within {+-} MPa for predicting tensile yield strengths in the range of 400-800 MPa.

  10. Return of the mini

    International Nuclear Information System (INIS)

    Ashmore, C.

    2001-01-01

    Partly as a result of the contentious nature of some large hydroelectric schemes, and continuing deregulation on a global scale, the mini hydro systems are enjoying unprecedented growth. This article discusses the reasons for the increase in demand for mini hydro systems, and describes Alstom Power Hydro's new, integrated 'water-to-wire' renewable energy solution which is a modular system which integrates the hydro-turbine, generator and controls to provide a single optimised product called the Mini-Aqua. The Mini-Aqua can be supplied inside a turnkey package including all civil works. The company is also looking to the future with development of its Powerformer technology for smaller-scale, grid-connected applications

  11. Consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo J. Fonseca D'El Rey

    2007-01-01

    Full Text Available CONTEXTO: A fobia social é um grave transtorno de ansiedade que traz incapacitação e sofrimento. OBJETIVOS: Investigar a consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN. MÉTODOS: Foi realizado um estudo da consistência interna do Mini-SPIN em uma amostra de 206 estudantes universitários da cidade de São Paulo, SP. RESULTADOS: A consistência interna do instrumento, analisada pelo coeficiente alfa de Cronbach, foi de 0,81. CONCLUSÕES: Esses achados permitiram concluir que a versão em português do Mini-SPIN exibiu resultados de boa consistência interna, semelhantes aos da versão original em inglês.BACKGROUND: Social phobia is a severe anxiety disorder that brings disability and distress. OBJECTIVES: To investigate the internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN. METHODS: We conducted a study of internal consistency of the Mini-SPIN in a sample of 206 college students of the city of São Paulo, SP. RESULTS: The internal consistency of the instrument, analyzed by Cronbach's alpha coefficient, was 0.81. CONCLUSIONS: These findings suggest that the Portuguese version of the Mini-SPIN has a good internal consistency, similar to those obtained with the original English version.

  12. Graphic software ''MiniG'' for the Mini-6

    International Nuclear Information System (INIS)

    Zen, J.

    1984-06-01

    MiniG is a set of subprograms, written and aimed at being used in Fortran for graphic applications in nuclear physics (histograms or point clouds). It includes three representation modes of axis scales (linear, semi-log and squared root), five types of vectors and numerous graphic symbols for spectra representation with or without notation (circle, cross, arrow, triangle, spiral, etc.). It offers also the possibilities of the software ''Plot-10'' of Tektronix, and accept all the types of graphic terminals of SATD connected to Mini-6 [fr

  13. Evaluation of Replacement Grafts and Punch Grafts in the Treatment of Vitiligo

    Directory of Open Access Journals (Sweden)

    Singh Ajit Kumar

    1980-01-01

    Full Text Available Thirtycasesof vitiligo eachwithminimum of two lesions undent replacement graft and multiple punch grafts in one lesion each. Complications observed at the recipient site like infection and raised nigosed surface were significantly more in replacement grafts. Hypopigmentation of the graft was significantly more when the disease was progressive.

  14. [Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)].

    Science.gov (United States)

    D'El Rey, Gustavo José Fonseca; Matos, Cláudia Wilmor

    2009-01-01

    Social phobia (also known as social anxiety disorder) is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN) in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426) of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version) demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive value of 98.6% and incorrect classification rate of 16.9%. With score of 7 points, was observed an increase in the specificity and positive predictive value (88.6% and 62.7%), while the sensitivity and negative predictive value (84.8% and 96.2%) remained high. The Portuguese version of the Mini-SPIN showed satisfactory psychometric qualities in terms of discriminative validity. In this study, the cut-off of 7, was considered to be the most suitable to screening of the generalized social phobia.

  15. P A Mini

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. P A Mini. Articles written in Bulletin of Materials Science. Volume 36 Issue 4 August 2013 pp 547-551. Composite supercapacitor electrodes made of activated carbon/PEDOT:PSS and activated carbon/doped PEDOT · T S Sonia P A Mini R Nandhini Kalluri Sujith Balakrishnan ...

  16. Validação da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN) Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)

    OpenAIRE

    Gustavo José Fonseca D'El Rey; Cláudia Wilmor Matos

    2009-01-01

    A fobia social (também conhecida como transtorno de ansiedade social) é um grave transtorno mental que traz sofrimento e incapacitação. O objetivo deste estudo foi validar para a língua portuguesa o Mini-Inventário de Fobia Social (Mini-SPIN) em uma amostra da população. Foi realizado um estudo da validade discriminativa do Mini-SPIN em uma amostra de 644 pessoas (grupo positivo para o Mini-SPIN: n = 218 e grupo controle/negativo: n = 426) de um estudo de prevalência de transtornos de ansieda...

  17. The development of a tensile-shear punch correlation for yield properties of model austenitic alloys

    International Nuclear Information System (INIS)

    Hankin, G.L.; Faulkner, R.G.; Hamilton, M.L.; Garner, F.A.

    1997-01-01

    The effective shear yield and maximum strengths of a set of neutron-irradiated, isotopically tailored austentic alloys were evaluated using the shear punch test. The dependence on composition and neutron dose showed the same trends as were observed in the corresponding miniature tensile specimen study conducted earlier. A single tensile-shear punch correlation was developed for the three alloys in which the maximum shear stress or Tresca criterion was successfully applied to predict the slope. The correlation will predict the tensile yield strength of the three different austenitic alloys tested to within ±53 MPa. The accuracy of the correlation improves with increasing material strength, to within ± MPa for predicting tensile yield strengths in the range of 400-800 MPa

  18. Effects of Sparring Load on Reaction Speed and Punch Force During the Precompetition and Competition Periods in Boxing.

    Science.gov (United States)

    Hukkanen, Esa; Häkkinen, Keijo

    2017-06-01

    Seven, male, national-level boxers (age, 20.3 ± 2.7 years; height, 1.80 ± 0.06 m; mass, 73.8 ± 11.1 kg) participated in this study to investigate the effects of sparring on reaction time and punch force of straight punches measured during the precompetition and competition periods. Heart rate and blood lactate concentrations were also monitored. Sparring load was chosen in accordance with the current rules: 3 × 3-minute bouts with 1-minute break in between. Reaction time of rear straight lengthened (p boxing-specific and explosive strength training.

  19. Splitting behaviour of timber loaded perpendicular to the grain by punched metal plates

    NARCIS (Netherlands)

    Schoenmakers, J.C.M.; Jorissen, A.J.M.; Leijten, A.J.M.; Aratake, S. xx

    2008-01-01

    Nowadays, prefabricated timber trusses are widely used as load-bearing roof structures. The majority of these trusses are produced with punched metal plates (PMP) to connect two or more timber elements of the same thickness, see Figure 2. In these structures sufficient overlap is required to prevent

  20. MiniCNT - A Tabletop Stellarator

    Science.gov (United States)

    Dugan, Chris; Pedersen, Thomas; Berkery, John

    2006-10-01

    MiniCNT is a scaled down version of the Columbia Non-Neutral Torus, a stellarator built to study confinement of non-neutral plasmas on magnetic surfaces. MiniCNT is a glass vacuum chamber capable of holding pressures six orders of magnitude below atmospheric pressure. Unlike CNT, in which plasmas are invisible, MiniCNT allows some collisions with neutrals, causing it to glow. Using two twelve-volt car batteries to power four magnetic coils, MiniCNT generates a 0.02 Tesla magnetic field. While CNT, being larger, is obviously more accurate, there are multiple benefits in MiniCNT. First, it is more flexible and can be adjusted to fit many scenarios easily. The car batteries can be switched for other power sources, the coils can be realigned, and the chamber can be pumped to various pressures of various gases. Also, it is visually accessible; while CNT has glass viewing ports and its plasma is dark, MiniCNT is made of glass and its plasma glows, allowing visualization of the magnetic surfaces.

  1. Mini-Cog and Mini-Mental State Examination: agreement in a cross-sectional study with an elderly sample.

    Science.gov (United States)

    Costa, Diogo; Severo, Milton; Fraga, Sílvia; Barros, Henrique

    2012-01-01

    We aimed to compare the Mini-Mental State Examination (MMSE) with the Mini-Cog, measuring agreement in participants' classification, using a general population sample. Cross-sectional evaluation of 609 community dwellers aged ≥60 years was performed by trained interviewers. Cohen's kappa and 95% confidence intervals (CI) were calculated to assess overall agreement, and Cronbach alphas computed to assess reliability. Two-parameter Item Response Theory models (difficulty and discrimination parameters) were used to assess discrimination. Considering MMSE cut-point for scores Mini-Cog's cut-point score Mini-Cog Mini-Cog Mini-Cog's alpha was 0.2776. Co-calibration according to inherent ability is graphically presented. Agreement between scales seems fragile in our sample. The discriminative and reliability analysis suggests a better performance for subsets of the MMSE compared with the Mini-Cog. Usefulness of calibrated scores is discussed. Copyright © 2012 S. Karger AG, Basel.

  2. Shear Punch Testing of BOR-60 Irradiated TEM Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, Tarik A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Quintana, Matthew Estevan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Tobias J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-13

    As a part of the project “High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation” an Integrated Research Program (IRP) project from the U.S. Department of Energy, Nuclear Energy University Programs (NEUP), TEM geometry samples of ferritic cladding alloys, Ni based super alloys and model alloys were irradiated in the BOR-60 reactor to ~16 dpa at ~370°C and ~400°C. Samples were sent to Los Alamos National Laboratory and subjected to shear punch testing. This report presents the results from this testing.

  3. Design of punching shear for prestressed slabs with unbonded tendons on internal columns

    Directory of Open Access Journals (Sweden)

    L. A. R. Luchi

    Full Text Available ABSTRACT This paper is related to the punching shear in prestressed slabs with unbonded tendons for interior columns calculated by the codes ABNT NBR 6118:2007, ABNT NBR 6118:2014, EN 1992-1-1:2004 e ACI 318-11. To calculate the punching shear resistance the formulations of the NBR 6118:07, effective until April/2014, did not consider the compression of the concrete in the plane of the slab, due to prestressing. Just the inclined components of some tendons were considered for total load applied relief, but this fact did not generate a significant difference, compared to reinforced concrete, because the inclination angle is very close to zero. The American and European provisions consider a portion related to the compression of the concrete in the planeof the slab. Differences in the results obtained by the four design codes will be exposed, showing that the EC2:04 and the NBR6118:14 achieved the best results.

  4. MiniDraw

    DEFF Research Database (Denmark)

    2018-01-01

    MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010.......MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010....

  5. Preoperative autologous plateletpheresis in patients undergoing open heart surgery.

    Directory of Open Access Journals (Sweden)

    Tomar Akhlesh

    2003-01-01

    Full Text Available Blood conservation is an important aspect of care provided to the patients undergoing cardiac operations with cardiopulmonary bypass (CPB. It is even more important in patients with anticipated prolonged CPB, redo cardiac surgery, patients having negative blood group and in patients undergoing emergency cardiac surgery. In prolonged CPB the blood is subjected to more destruction of important coagulation factors, in redo surgery the separation of adhesions leads to increased bleeding and difficulty in achieving the haemostasis and in patients with negative blood group and emergency operations, the availability of sufficient blood can be a problem. Harvesting the autologous platelet rich plasma (PRP can be a useful method of blood conservation in these patients. The above four categories of patients were prospectively studied, using either autologous whole blood donation or autologous platelet rich plasma (PRP harvest in the immediate pre-bypass period. Forty two patients were included in the study and randomly divided into two equal groups of 21 each, control group (Group I in which one unit of whole blood was withdrawn, and PRP group (Group II where autologous plateletpheresis was utilised. After reversal of heparin, autologous whole blood was transfused in the control group and autologous PRP was transfused in the PRP group. The chest tube drainage and the requirement of homologous blood and blood products were recorded. Average PRP harvest was 643.33 +/- 133.51 mL in PRP group and the mean whole blood donation was 333.75 +/- 79.58 mL in the control group. Demographic, preoperative and intra operative data showed no statistically significant differences between the two groups. The PRP group patients drained 26.44% less (p<0.001 and required 38.5% less homologous blood and blood products (p<0.05, in the postoperative period. Haemoglobin levels on day zero (day of operation and day three were statistically not different between the two groups. We

  6. Autologous fat transplantation for labia majora reconstruction.

    Science.gov (United States)

    Vogt, P M; Herold, C; Rennekampff, H O

    2011-10-01

    A case of autologous fat transplantation for labia majora augmentation after ablative surgery is presented. The patient reported pain and deformity of the left labium majus after resection for Bowen's disease. The symptoms had not been solved by classic plastic surgical reconstructions including a pudendal thigh fasciocutaneous flap. Use of autologous fat transplantation facilitated an improved aesthetic result while preserving residual sensation to the external genitalia and improving symptoms of mucosal exposure and dryness.

  7. Autologous bone marrow purging with LAK cells.

    Science.gov (United States)

    Giuliodori, L; Moretti, L; Stramigioli, S; Luchetti, F; Annibali, G M; Baldi, A

    1993-12-01

    In this study we will demonstrate that LAK cells, in vitro, can lyse hematologic neoplastic cells with a minor toxicity of the staminal autologous marrow cells. In fact, after bone marrow and LAK co-culture at a ratio of 1/1 for 8 hours, the inhibition on the GEMM colonies resulted to be 20% less compared to the untreated marrow. These data made LAK an inviting agent for marrow purging in autologous bone marrow transplantation.

  8. Mini-grid Policy Tool-kit. Policy and business frameworks for successful mini-grid roll-outs

    International Nuclear Information System (INIS)

    Franz, Michael; Hayek, Niklas; Peterschmidt, Nico; Rohrer, Michael; Kondev, Bozhil; Adib, Rana; Cader, Catherina; Carter, Andrew; George, Peter; Gichungi, Henry; Hankins, Mark; Kappiah, Mahama; Mangwengwende, Simbarashe E.

    2014-01-01

    The Mini-grid Policy Tool-kit is for policy makers to navigate the mini-grid policy design process. It contains information on mini-grid operator models, the economics of mini-grids, and necessary policy and regulation that must be considered for successful implementation. The publication specifically focuses on Africa. Progress on extending the electricity grid in many countries has remained slow because of high costs of gird-extension and limited utility/state budgets for electrification. Mini-grids provide an affordable and cost-effective option to extend needed electricity services. Putting in place the right policy for min-grid deployment requires considerable effort but can yield significant improvement in electricity access rates as examples from Kenya, Senegal and Tanzania illustrate. The tool-kit is available in English, French and Portuguese

  9. Small Punch Tests at Oxide Scales Surface of Structural Steel and Low Silicon Steel

    Czech Academy of Sciences Publication Activity Database

    Hrabovský, J.; Dobeš, Ferdinand; Horský, J.

    2014-01-01

    Roč. 82, 3-4 (2014), s. 297-310 ISSN 0030-770X Institutional support: RVO:68081723 Keywords : Small punch * Oxide scales * X-ray diffraction * Mechanical properties Subject RIV: JK - Corrosion ; Surface Treatment of Materials Impact factor: 1.140, year: 2014

  10. Review of mini-clinical evaluation exercise (mini-CEX in a psychiatry clerkship

    Directory of Open Access Journals (Sweden)

    Meresh E

    2018-04-01

    Full Text Available Edwin Meresh,1 David Daniels,2 Aparna Sharma,1 Murali Rao,1 Kaushal Mehta,3 David Schilling1 1Department of Psychiatry and Behavioral Neurosciences, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA; 2Department of Psychiatry, Medstar Georgetown University Hospital, Washington, DC, USA; 3School of Public Health, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL USA Background: Direct observation of medical students with actual patients is important for the assessment of clinical skills including interviewing and counseling skills. This article describes medical students’ experience of mini-clinical evaluation exercise (mini-CEX during their clerkship in consultation psychiatry. Materials and methods: In our center during inpatient consultation psychiatry clerkship, all rotating students are expected to complete one mini-CEX assessment as part of their clinical training. We conducted retrospective analysis of mini-CEX ratings completed from 2013 to 2016. All evaluations took place at inpatient medical setting in patients admitted with medical conditions and psychiatric comorbidities. Results: A total of 113 evaluations were reviewed. The time examiner observed the interaction of a student with the patient was 14.24 minutes (mean, and the time spent in providing feedback to the student was 9.71 minutes. Complexity of problem was rated as low in 0.88% (n=1, moderate in 50.44% (n=57, and high in 48.67% (n=55. Highest ratings were for professionalism, similar to previous reports. Total score calculated by examiner showed no difference by the complexity of the patient; however, we observed a trend in higher counseling score for the high complexity group. Conclusion: Mini-CEX assessment during busy clerkship is feasible with good outcomes. Direct observation of medical trainees with actual patients is important for the assessment of performance-based clinical skills. Hospital psychiatry rotation

  11. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    OpenAIRE

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnos...

  12. Autologous fat grafting: use of closed syringe microcannula system for enhanced autologous structural grafting

    Directory of Open Access Journals (Sweden)

    Alexander RW

    2013-04-01

    Full Text Available Robert W Alexander,1 David Harrell2 1Department of Surgery, School of Medicine and Dentistry, University of Washington, Seattle, WA, USA; 2Harvest-Terumo Inc, Plymouth, MA, USA Objectives: Provide background for use of acquiring autologous adipose tissue as a tissue graft and source of adult progenitor cells for use in cosmetic plastic surgery. Discuss the background and mechanisms of action of closed syringe vacuum lipoaspiration, with emphasis on accessing adipose-derived mesenchymal/stromal cells and the stromal vascular fraction (SVF for use in aesthetic, structural reconstruction and regenerative applications. Explain a proven protocol for acquiring high-quality autologous fat grafts (AFG with use of disposable, microcannula systems. Design: Explain the components and advantage of use of the patented super luer-lock and microcannulas system for use with the closed-syringe system. A sequential explanation of equipment selection for minimally traumatic lipoaspiration in small volumes is presented, including use of blunt injection cannulas to reduce risk of embolism. Results: Thousands of AFG have proven safe and efficacious for lipoaspiration techniques for large and small structural fat grafting procedures. The importance and advantages of gentle harvesting of the adipose tissue complex has become very clear in the past 5 years. The closed-syringe system offers a minimally invasive, gentle system with which to mobilize subdermal fat tissues in a suspension form. Resulting total nuclear counting of undifferentiated cells of the adipose-derived -SVF suggests that the yield achieved is better than use of always-on, constant mechanical pump applied vacuum systems. Conclusion: Use of a closed-syringe lipoaspiration system featuring disposable microcannulas offers a safe and effective means of harvesting small volumes of nonmanipulated adipose tissues and its accompanying progenitor cells within the SVF. Closed syringes and microcannulas are

  13. iPad mini for dummies

    CERN Document Server

    Baig, Edward C

    2014-01-01

    Find out why the iPad mini has never been bigger This new edition of iPad mini For Dummies covers all the latest tips and tricks for getting an even bigger bang out of your iPad mini. Presented in full-color and written in the straightforward but fun language that has defined the For Dummies brand for more than twenty years, this friendly guide walks you through the multitouch interface, going online, getting connected, packing your iPad mini with apps, games, e-books, photos, music, and movies, synchronizing your data, texting with iMessage, working with Siri, importing pictures and launching

  14. Validação da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo José Fonseca D'El Rey

    2009-12-01

    Full Text Available A fobia social (também conhecida como transtorno de ansiedade social é um grave transtorno mental que traz sofrimento e incapacitação. O objetivo deste estudo foi validar para a língua portuguesa o Mini-Inventário de Fobia Social (Mini-SPIN em uma amostra da população. Foi realizado um estudo da validade discriminativa do Mini-SPIN em uma amostra de 644 pessoas (grupo positivo para o Mini-SPIN: n = 218 e grupo controle/negativo: n = 426 de um estudo de prevalência de transtornos de ansiedade na cidade de Santo André (SP. A versão em português do Mini-SPIN (com escore de 6 pontos, sugerido na versão original em inglês demonstrou uma sensibilidade de 95,0%, especificidade de 80,3%, valor preditivo positivo de 52,8%, valor preditivo negativo de 98,6% e taxa de classificação incorreta de 16,9%. Com escores de 7 pontos, foi observado um aumento na especificidade e no valor preditivo positivo (88,6% e 62,7%, sendo que a sensibilidade e o valor preditivo negativo (84,8% e 96,2% mantiveram-se altos. A versão em português do Mini-SPIN apresentou qualidades psicométricas satisfatórias em termos de validade discriminativa. Neste estudo, o ponto de corte igual a 7 mostrou-se mais adequado para a identificação da fobia social generalizada.Social phobia (also known as social anxiety disorder is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426 of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive

  15. Preoperative autologous plateletpheresis in patients undergoing open heart surgery.

    Science.gov (United States)

    Tomar, Akhlesh S; Tempe, Deepak K; Banerjee, Amit; Hegde, Radhesh; Cooper, Andrea; Khanna, S K

    2003-07-01

    Blood conservation is an important aspect of care provided to the patients undergoing cardiac operations with cardiopulmonary bypass (CPB). It is even more important in patients with anticipated prolonged CPB, redo cardiac surgery, patients having negative blood group and in patients undergoing emergency cardiac surgery. In prolonged CPB the blood is subjected to more destruction of important coagulation factors, in redo surgery the separation of adhesions leads to increased bleeding and difficulty in achieving the haemostasis and in patients with negative blood group and emergency operations, the availability of sufficient blood can be a problem. Harvesting the autologous platelet rich plasma (PRP) can be a useful method of blood conservation in these patients. The above four categories of patients were prospectively studied, using either autologous whole blood donation or autologous platelet rich plasma (PRP) harvest in the immediate pre-bypass period. Forty two patients were included in the study and randomly divided into two equal groups of 21 each, control group (Group I) in which one unit of whole blood was withdrawn, and PRP group (Group II) where autologous plateletpheresis was utilised. After reversal of heparin, autologous whole blood was transfused in the control group and autologous PRP was transfused in the PRP group. The chest tube drainage and the requirement of homologous blood and blood products were recorded. Average PRP harvest was 643.33 +/- 133.51 mL in PRP group and the mean whole blood donation was 333.75 +/- 79.58 mL in the control group. Demographic, preoperative and intra operative data showed no statistically significant differences between the two groups. The PRP group patients drained 26.44% less (pblood products (pconservation in terms of better haemostasis, and less requirement of blood and blood products in the postoperative period as compared with the autologous whole blood donation. This technique can be especially useful in the

  16. Cost effectiveness of autologous blood transfusion – A developing ...

    African Journals Online (AJOL)

    An autologous blood donation program was set up at National Orthopaedic Hospital, Igbobi Lagos in 1992 in response to the rising sero prevalence of HIV observed in our “relative replacement” donors. A retrospective batch analysis of patients who received autologous transfusion and those who received homologous ...

  17. Study of the upper die clamping conditions in the small punch test

    Czech Academy of Sciences Publication Activity Database

    Andrés, D.; Dymáček, Petr

    86A, DEC (2016), s. 117-123 ISSN 0167-8442 R&D Projects: GA MŠk(CZ) ED1.1.00/02.0068 Institutional support: RVO:68081723 Keywords : Small punch test * Finite element method * Parametric study * High temperature * Creep Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.659, year: 2016 http://www.sciencedirect.com/science/article/pii/S0167844216301835

  18. Short term creep small punch testing of P91 and P92 steels,

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr

    2011-01-01

    Roč. 465, - (2011), s. 179-182 ISSN 1013-9826. [Materials Structure & Micromechanics of Fracture 6. Brno, 28.6.2010-30.6,2010] R&D Projects: GA AV ČR(CZ) IAA200410801 Institutional research plan: CEZ:AV0Z20410507 Keywords : creep * small punch test * chromium steel Subject RIV: JG - Metallurgy

  19. Spurious RF signals emitted by mini-UAVs

    NARCIS (Netherlands)

    Schleijpen, R.; Voogt, V.; Zwamborn, P.; Oever, J. van den

    2016-01-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to

  20. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  1. Evaluation and treatment of vitiligo

    NARCIS (Netherlands)

    Vrijman, C.

    2015-01-01

    This thesis considers several aspects of vitiligo; it investigates (i) provoking factors of vitiligo, (ii) the prevalence of thyroid disease, (iii) the efficacy and safety of autologous punch- and cell suspension grafting and (iv) measurement properties of outcome measures for vitiligo. Chapter 2.1

  2. Accelerated aging, natural aging, and small punch testing of gamma-air sterilized polycarbonate urethane acetabular components.

    Science.gov (United States)

    Kurtz, S M; Siskey, R; Reitman, M

    2010-05-01

    The objectives of this study were three-fold: (1) to determine the applicability of the small punch test to characterize Bionate 80A polycarbonate urethane (PCU) acetabular implants; (2) to evaluate the susceptibility of PCU acetabular implants to exhibit degradation of mechanical behavior following gamma irradiation in air and accelerated aging; and (3) to compare the oxidation of gamma-air sterilized PCU following accelerated aging and 5 years of natural shelf aging. In addition to attenuated total reflectance-Fourier transform infrared spectroscopy, we also adapted a miniature specimen mechanical test, the small punch test, for the deformable PCU cups. Accelerated aging was performed using ASTM F2003, a standard test that represents a severe oxidative challenge. The results of this study suggest that the small punch test is sufficiently sensitive and reproducible to discriminate slight differences in the large-deformation mechanical behavior of Bionate 80A following accelerated aging. The gamma-air sterilized PCU had a reduction of 9% in ultimate load after aging. Five years of shelf aging had little effect on the mechanical properties of the PCU. Overall, our findings suggest that the Bionate 80A material has greater oxidative stability than ultra-high molecular weight polyethylene following gamma irradiation in air and exposure to a severe oxidative challenge. (c) 2010 Wiley Periodicals, Inc.

  3. Cord Blood Banking Standards: Autologous Versus Altruistic.

    Science.gov (United States)

    Armitage, Sue

    2015-01-01

    Cord blood (CB) is either donated to public CB banks for use by any patient worldwide for whom it is a match or stored in a private bank for potential autologous or family use. It is a unique cell product that has potential for treating life-threatening diseases. The majority of CB products used today are for hematopoietic stem cell transplantation and are accessed from public banks. CB is still evolving as a hematopoietic stem cell source, developing as a source for cellular immunotherapy products, such as natural killer, dendritic, and T-cells, and fast emerging as a non-hematopoietic stem cell source in the field of regenerative medicine. This review explores the regulations, standards, and accreditation schemes that are currently available nationally and internationally for public and private CB banking. Currently, most of private banking is under regulated as compared to public banking. Regulations and standards were initially developed to address the public arena. Early responses from the medical field regarding private CB banking was that at the present time, because of insufficient scientific data to support autologous banking and given the difficulty of making an accurate estimate of the need for autologous transplantation, private storage of CB as "biological insurance" should be discouraged (1, 2, 3). To ensure success and the true realization of the full potential of CB, whether for autologous or allogeneic use, it is essential that each and every product provided for current and future treatments meets high-quality, international standards.

  4. Psychometric Evaluation of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID).

    Science.gov (United States)

    Duncan, Laura; Georgiades, Kathy; Wang, Li; Van Lieshout, Ryan J; MacMillan, Harriet L; Ferro, Mark A; Lipman, Ellen L; Szatmari, Peter; Bennett, Kathryn; Kata, Anna; Janus, Magdalena; Boyle, Michael H

    2017-12-04

    The goals of the study were to examine test-retest reliability, informant agreement and convergent and discriminant validity of nine DSM-IV-TR psychiatric disorders classified by parent and youth versions of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID). Using samples drawn from the general population and child mental health outpatient clinics, 283 youth aged 9 to 18 years and their parents separately completed the MINI-KID with trained lay interviewers on two occasions 7 to 14 days apart. Test-retest reliability estimates based on kappa (κ) went from 0.33 to 0.79 across disorders, samples and informants. Parent-youth agreement on disorders was low (average κ = 0.20). Confirmatory factor analysis provided evidence supporting convergent and discriminant validity. The MINI-KID disorder classifications yielded estimates of test-retest reliability and validity comparable to other standardized diagnostic interviews in both general population and clinic samples. These findings, in addition to the brevity and low administration cost, make the MINI-KID a good candidate for use in epidemiological research and clinical practice. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Enhancements to the Image Analysis Tool for Core Punch Experiments and Simulations (vs. 2014)

    Energy Technology Data Exchange (ETDEWEB)

    Hogden, John Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Unal, Cetin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-06

    A previous paper (Hogden & Unal, 2012, Image Analysis Tool for Core Punch Experiments and Simulations) described an image processing computer program developed at Los Alamos National Laboratory. This program has proven useful so developement has been continued. In this paper we describe enhacements to the program as of 2014.

  6. [Bone remodeling and modeling/mini-modeling.

    Science.gov (United States)

    Hasegawa, Tomoka; Amizuka, Norio

    Modeling, adapting structures to loading by changing bone size and shapes, often takes place in bone of the fetal and developmental stages, while bone remodeling-replacement of old bone into new bone-is predominant in the adult stage. Modeling can be divided into macro-modeling(macroscopic modeling)and mini-modeling(microscopic modeling). In the cellular process of mini-modeling, unlike bone remodeling, bone lining cells, i.e., resting flattened osteoblasts covering bone surfaces will become active form of osteoblasts, and then, deposit new bone onto the old bone without mediating osteoclastic bone resorption. Among the drugs for osteoporotic treatment, eldecalcitol(a vitamin D3 analog)and teriparatide(human PTH[1-34])could show mini-modeling based bone formation. Histologically, mature, active form of osteoblasts are localized on the new bone induced by mini-modeling, however, only a few cell layer of preosteoblasts are formed over the newly-formed bone, and accordingly, few osteoclasts are present in the region of mini-modeling. In this review, histological characteristics of bone remodeling and modeling including mini-modeling will be introduced.

  7. The MiniBooNE Detector

    OpenAIRE

    MiniBooNE Collaboration

    2008-01-01

    The MiniBooNE neutrino detector was designed and built to look for muon-neutrino to electron-neutrino oscillations in the mixing parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  8. A DNA mini-barcode for land plants.

    Science.gov (United States)

    Little, Damon P

    2014-05-01

    Small portions of the barcode region - mini-barcodes - may be used in place of full-length barcodes to overcome DNA degradation for samples with poor DNA preservation. 591,491,286 rbcL mini-barcode primer combinations were electronically evaluated for PCR universality, and two novel highly universal sets of priming sites were identified. Novel and published rbcL mini-barcode primers were evaluated for PCR amplification [determined with a validated electronic simulation (n = 2765) and empirically (n = 188)], Sanger sequence quality [determined empirically (n = 188)], and taxonomic discrimination [determined empirically (n = 30,472)]. PCR amplification for all mini-barcodes, as estimated by validated electronic simulation, was successful for 90.2-99.8% of species. Overall Sanger sequence quality for mini-barcodes was very low - the best mini-barcode tested produced sequences of adequate quality (B20 ≥ 0.5) for 74.5% of samples. The majority of mini-barcodes provide correct identifications of families in excess of 70.1% of the time. Discriminatory power noticeably decreased at lower taxonomic levels. At the species level, the discriminatory power of the best mini-barcode was less than 38.2%. For samples believed to contain DNA from only one species, an investigator should attempt to sequence, in decreasing order of utility and probability of success, mini-barcodes F (rbcL1/rbcLB), D (F52/R193) and K (F517/R604). For samples believed to contain DNA from more than one species, an investigator should amplify and sequence mini-barcode D (F52/R193). © 2013 John Wiley & Sons Ltd.

  9. Autologous chondrocyte implantation: superior biologic properties of hyaline cartilage repairs.

    Science.gov (United States)

    Henderson, Ian; Lavigne, Patrick; Valenzuela, Herminio; Oakes, Barry

    2007-02-01

    Information regarding the quality of autologous chondrocyte implantation repair is needed to determine whether the current autologous chondrocyte implantation surgical technology and the subsequent biologic repair processes are capable of reliably forming durable hyaline or hyaline-like cartilage in vivo. We report and analyze the properties and qualities of autologous chondrocyte implantation repairs. We evaluated 66 autologous chondrocyte implantation repairs in 57 patients, 55 of whom had histology, indentometry, and International Cartilage Repair Society repair scoring at reoperation for mechanical symptoms or pain. International Knee Documentation Committee scores were used to address clinical outcome. Maximum stiffness, normalized stiffness, and International Cartilage Repair Society repair scoring were higher for hyaline articular cartilage repairs compared with fibrocartilage, with no difference in clinical outcome. Reoperations revealed 32 macroscopically abnormal repairs (Group B) and 23 knees with normal-looking repairs in which symptoms leading to arthroscopy were accounted for by other joint disorders (Group A). In Group A, 65% of repairs were either hyaline or hyaline-like cartilage compared with 28% in Group B. Autologous chondrocyte repairs composed of fibrocartilage showed more morphologic abnormalities and became symptomatic earlier than hyaline or hyaline-like cartilage repairs. The hyaline articular cartilage repairs had biomechanical properties comparable to surrounding cartilage and superior to those associated with fibrocartilage repairs.

  10. What is the role of autologous blood transfusion in major spine surgery?

    Science.gov (United States)

    Kumar, Naresh; Chen, Yongsheng; Nath, Chinmoy; Liu, Eugene Hern Choon

    2012-06-01

    Major spine surgery is associated with significant blood loss, which has numerous complications. Blood loss is therefore an important concern when undertaking any major spine surgery. Blood loss can be addressed by reducing intraoperative blood loss and replenishing perioperative blood loss. Reducing intraoperative blood loss helps maintain hemodynamic equilibrium and provides a clearer operative field during surgery. Homologous blood transfusion is still the mainstay for replenishing blood loss in major spine surgery across the world, despite its known adverse effects. These significant adverse effects can be seen in up to 20% of patients. Autologous blood transfusion avoids the risks associated with homologous blood transfusion and has been shown to be cost-effective. This article reviews the different methods of autologous transfusion and focuses on the use of intraoperative cell salvage in major spine surgery. Autologous blood transfusion is a proven alternative to homologous transfusion in major spine surgery, avoiding most, if not all of these adverse effects. However, autologous blood transfusion rates in major spine surgery remain low across the world. Autologous blood transfusion may obviate the need for homologous transfusion completely. We encourage spine surgeons to consider autologous blood transfusion wherever feasible.

  11. Regeneration of Tissues and Organs Using Autologous Cells

    Energy Technology Data Exchange (ETDEWEB)

    Anthony Atala

    2010-04-28

    The Joint Commission for Health Care Organizations recently declared the shortage of transplantable organs and tissues a public health crisis. As such, there is about one death every 30 seconds due to organ failure. Complications and rejection are still significant albeit underappreciated problems. It is often overlooked that organ transplantation results in the patient being placed on an immune suppression regimen that will ultimate shorten their life span. Patients facing reconstruction often find that surgery is difficult or impossible due to the shortage of healthy autologous tissue. In many cases, autografting is a compromise between the condition and the cure that can result in substantial diminution of quality of life. The national cost of caring for persons who might benefit from engineered tissues or organs has reached $600 billion annually. Autologous tissue technologies have been developed as an alternative to transplantation or reconstructive surgery. Autologous tissues derived from the patient's own cells are capable of correcting numerous pathologies and injuries. The use of autologous cells eliminates the risks of rejection and immunological reactions, drastically reduces the time that patients must wait for lifesaving surgery, and negates the need for autologous tissue harvest, thereby eliminating the associated morbidities. In fact, the use of autologous tissues to create functional organs is one of the most important and groundbreaking steps ever taken in medicine. Although the basic premise of creating tissues in the laboratory has progressed dramatically, only a limited number of tissue developments have reached the patients to date. This is due, in part, to the several major technological challenges that require solutions. To that end, we have been in pursuit of more efficient ways to expand cells in vitro, methods to improve vascular support so that relevant volumes of engineered tissues can be grown, and constructs that can mimic the

  12. Precision hole punching on composite fiber reinforced polymer panels

    Science.gov (United States)

    Abdullah, A. B.; Zain, M. S. M.; Chan, H. Y.; Samad, Z.

    2017-12-01

    Structural materials, such as composite panels, can only be assembled, and in most cases through the use of fasteners, which are fitted into the drilled holes. However, drilling is costly and time consuming, thus affecting productivity. This research aims to develop an alternative method to drilling. In this paper, the precision of the holes was measured and the effects of the die clearance to the areas around the holes were evaluated. Measurement and evaluation were performed based on the profile of the holes constructed using Alicona IFM, a 3D surface measurement technique. Results showed that punching is a potential alternative to drilling but still requires improvements.

  13. Advanced Modelling of Trusses with Punched Metal Plate Fasteners

    DEFF Research Database (Denmark)

    Ellegaard, Peter; Nielsen, Jacob

    Most of the finite element programs for design of timber trusses with punched metal fasteners are based on models using beam and fictitious elements. Different models have been used for different types of joints. Common problems for all the models are how to calculate the forces in the nail groups...... and the plates and furthermore, how big 'the deformations in the joints are. By developing an advanced model that includes all parts of the joint, i.e. plate, nail groups and contact it is possible to give a better description of the joint. An advanced model with these properties is presented. The advanced model...

  14. 'Mini' total body irradiation and allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.; Koleva, I.; Avramova, V.; Vassileva, V.; Georgieva, S.; Sultanov, B.

    2006-01-01

    Full text: The total body irradiation (TBI) combined with intensive chemotherapy plays an important role in the preparation of patients for bone marrow transplantation (BMT). The first autologous BMT in Bulgaria was performed in 1997 in the Specialized Pediatric Hospital for Active Treatment (SPHAT) of oncohematological diseases. The first TBI, followed by allogeneic BMT, was carried out in 2002 in the 'Queen Giovanna' University Hospital, after which its routine application as a basic form of large field radiotherapy and a main stage of the conditioning regimen for BMT was started. Fourteen allogeneic BMTs including TBI as a basic conditioning regimen have been performed till May 2006. The objective of the present report is to present the first clinical observations in the Bulgarian oncological practice on 'mini' TBI followed by allogeneic blood stem cell transplantation. During the period October 2005 - May 2006, 'mini' TBI followed by allogeneic BMT was carried out for two patients of the age 43 and 50 years. The diagnosis of both patients was acute non-lymphoblastic leukemia, in the remission stage, after one relapse, respectively. Intensive preceding chemotherapy was applied for both patients. A conditioning regimen was applied including the fludarabine purine analogue (3 x 30 mg/m 2 ) and 200 cGy TBI. It was followed by transplantation of allogeneic cell concentrate containing 2.5 x10 6 /kg CD34+ and 4.0 x10 6 /kg CD34+ blood stem cells of partially compatible family donors (a sister and a son), which were tolerable for the patients without complications. Cyclosporine and mycophelonate mofetile were applied as post-transplantation treatment. Active antibiotic, antiviral, symptomatic and substituting therapy, as well as GvHD prophylaxis was applied for both patients. Good clinical tolerance was recorded for the applied low dose conditioning regimen. The patients were discharged within 30 days in good general condition and stable draft action, with

  15. "Center punch" and "whole spot" bioanalysis of apixaban in human dried blood spot samples by UHPLC-MS/MS.

    Science.gov (United States)

    Zheng, Naiyu; Yuan, Long; Ji, Qin C; Mangus, Heidi; Song, Yan; Frost, Charles; Zeng, Jianing; Aubry, Anne-Françoise; Arnold, Mark E

    2015-04-15

    Apixaban (Eliquis™) was developed by Bristol-Myers Squibb (BMS) and Pfizer to use as an antithrombotic/anticoagulant agent and has been recently approved for the prevention of stroke and systemic embolism in patients with nonvalvular atrial fibrillation. A clinical study of apixaban, sponsored by BMS and Pfizer, included a pilot exploratory portion to evaluate the potential for future drug concentration monitoring using dried blood spot (DBS) sample collection. For DBS sample collection, a fixed blood volume was dispensed onto a DBS card by either regular volumetric pipette (venous blood collection) or capillary dispenser (finger prick blood collection). A 96-well semi-automated liquid-liquid extraction sample preparation procedure was developed to provide clean extracts for UHPLC-MS/MS quantitation. Assays using both partial-spot center punch and whole spot punch were developed and validated. The linear dynamic ranges for all the analyses were from 0.5 to 500 ng/mL. The coefficient of determination (r(2)) values was >0.9944 for all the validation runs. For the center punch approach, the intra-assay precision (%CV) was within 4.4% and inter-assay precision was within 2.6%. The assay accuracy, expressed as %Dev., was within ± 5.4% of the nominal concentrations. One accuracy and precision run was performed using the whole spot approach, the intra-assay precision (%CV) was within 7.1% and the accuracy was within ± 8.0% of the nominal concentrations. In contrast to the center punch approach, the whole spot approach eliminated the effect of hematocrit and high lipids on the analysis of apixaban in human DBS when an accurate sample blood volume was collected on DBS cards. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Findings from the experience with the punch technique for auditory osseointegrated implants: A retrospective single center comparative study.

    Science.gov (United States)

    Bonilla, Alfonso; Magri, Carlos; Juan, Eulalia

    To compare the punch technique and linear incision with soft tissue reduction for the placement of auditory osseointegrated implants (AOI) and analyze results of osseointegration obtained with the punch technique as measured with the Implant Stability Quotient (ISQ). Case review of 34 patients who received auditory osseointegrated implants between January 2010 and July 2015 and were divided into two groups according to the surgical technique: 18 with the punch technique (PT) and 16 with the linear incision technique (LI). Minimum follow-up was four months (mean: 24 months; range 4-64 months). Included in the analysis were patient profiles and records of the demographic data, surgical indications, surgical technique, implant placement, surgical time, intraoperative complications, as well as postsurgical complications (Holgers classification) and implant stability quotients (ISQ). Use of larger abutments was significantly greater in the PT group (PT, 10mm; LI, 6mm, p<0.001). The PT technique resulted in a shorter procedure than the LI (PT, 20min; LI, 45min, p<0.001). Holgers classification scores identified significantly fewer skin complications one week after surgery for the PT group; however, only small differences were seen between the two groups at the one- and three-month control visits. As shown for our cohort, the punch technique for surgical placement of AOI is faster and presents fewer immediate postoperative complications when compared to the linear incision technique. The clinical application of the ISQ is a useful, easy method to demonstrate the status of osseointegration and, thus, the stability of the device. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  17. The MiniBooNE detector

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, A.A.; Anderson, C.E.; Bartoszek, L.M.; Bazarko, A.O.; Brice, S.J.; Brown, B.C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J.M.; Cox, D.C.; Curioni, A.; Djurcic, Z.; Finley, D.A.; Fleming, B.T.; Ford, R.; Garcia, F.G.; Garvey, G.T.; Green, C.; Green, J.A.

    2009-01-01

    The MiniBooNE neutrino detector was designed and built to look for ν μ →ν e oscillations in the (sin 2 2θ,Δm 2 ) parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  18. Are Ducted Mini-Splits Worth It?

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jonathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maguire, Jeffrey B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, Cheryn E. [Pacific Northwest National Laboratory; Zhang, Jason [Pacific Northwest National Laboratory

    2018-02-01

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

  19. Design guidelines for mini-roundabouts

    CSIR Research Space (South Africa)

    Emslie, I

    1997-03-01

    Full Text Available Guidelines for Traffic Calming. Concepts and principles relating to the use of mini-roundabouts as a form of intersection control and in the traffic calming context are discussed. Warrants for the implementation of mini-roundabouts and design standards...

  20. MiniBooNE Oscillation Results

    International Nuclear Information System (INIS)

    Djurcic, Zelimir

    2009-01-01

    These proceedings summarize the MiniBooNE ν μ → ν e results, describe the first (bar ν) μ → (bar ν) e result, and current analysis effort with the NuMI neutrinos detected in the miniBooNE detector

  1. APPLICATION OF PBL IN THE COURSE FLUID AND ELECTRICAL DRIVE SYSTEMS, CASE STUDY: MANUFACTURING AN AUTOMATED PUNCH MACHINE

    Directory of Open Access Journals (Sweden)

    Ahmad Sedaghat

    2017-01-01

    Full Text Available The PBL unit of fluid and electrical drive systems is taught in final semester of undergraduates in mechanical engineering department of the Australian College of Kuwait (ACK. The recent project on an automated punching machine is discovered more appealing to both students and instructors in triggering new ideas and satisfaction end results. In this case study, the way this PBL unit is coordinated and facilitated is explained. Two examples of student works are presented. The aim is to expose the students to real world engineering problems but in a satisfying manner. Similar to real life problems for engineers, restrictions are applied for the students on costs, availability of ACK facilities, and application of automation tools. Students are directly engaged by using technical standards on punching heads and dies, standard tensile testing of plates, and so on. Arduino microprocessor programming, an open-source hardware and software electronic platform, and electro-pneumatic devices are adopted for developing the automated punching machine. The goal of the PBL course is to acquaint students learning based on the concepts of team working, engineering design, professional manufacturing, and sequential testing of the end product. It is found that students achieved their best and developed new skills in this PBL unit as reflected in their portfolios.

  2. Efficacy of autologous platelets in macular hole surgery.

    Science.gov (United States)

    Konstantinidis, Aristeidis; Hero, Mark; Nanos, Panagiotis; Panos, Georgios D

    2013-01-01

    The introduction of optical coherence tomography has allowed accurate measurement of the size of macular holes. A retrospective consecutive review was performed of 21 patients undergoing macular hole repair with vitrectomy, gas tamponade, and autologous platelet injection and we assessed the effect of macular hole parameters on anatomic and functional outcomes. We looked at the demographic features, final visual outcome, and anatomical closure. Twenty-one patients were included in the study. They underwent routine vitrectomy with gas tamponade (C3F8) and injection of autologous platelets. All patients were advised to maintain a facedown posture for 2 weeks. Anatomical closure was confirmed in all cases and 20 out of 21 of patients had improved postoperative visual acuity by two or more lines. In our series, the macular hole dimensions did not have much effect on the final results. The use of autologous platelets and strict facedown posture seems to be the deciding factor in good anatomical and visual outcome irrespective of macular hole dimensions.

  3. Task Shifting and Skin Punch for the Histologic Diagnosis of Kaposi's Sarcoma in Sub-Saharan Africa: A Public Health Solution to a Public Health Problem.

    Science.gov (United States)

    Laker-Oketta, Miriam O; Wenger, Megan; Semeere, Aggrey; Castelnuovo, Barbara; Kambugu, Andrew; Lukande, Robert; Asirwa, F Chite; Busakhala, Naftali; Buziba, Nathan; Diero, Lameck; Wools-Kaloustian, Kara; Strother, Robert Matthew; Bwana, Mwebesa; Muyindike, Winnie; Amerson, Erin; Mbidde, Edward; Maurer, Toby; Martin, Jeffrey

    2015-01-01

    Fueled by HIV, sub-Saharan Africa has the highest incidence of Kaposi's sarcoma (KS) in the world. Despite this, KS diagnosis in the region is based mostly on clinical grounds. Where biopsy is available, it has traditionally been excisional and performed by surgeons, resulting in multiple appointments, follow-up visits for suture removal, and substantial costs. We hypothesized that a simpler approach - skin punch biopsy - would make histologic diagnosis more accessible. To address this, we provided training and equipment for skin punch biopsy of suspected KS to three HIV clinics in East Africa. The procedure consisted of local anesthesia followed by a disposable cylindrical punch blade to obtain specimens. Hemostasis is facilitated by Gelfoam®. Patients removed the dressing after 4 days. From 2007 to 2013, 2,799 biopsies were performed. Although originally targeted to be used by physicians, biopsies were performed predominantly by nurses (62%), followed by physicians (15%), clinical officers (12%) and technicians (11%). There were no reports of recurrent bleeding or infection. After minimal training and provision of inexpensive equipment (USD 3.06 per biopsy), HIV clinics in East Africa can integrate same-day skin punch biopsy for suspected KS. Task shifting from physician to non-physician greatly increases access. Skin punch biopsy should be part of any HIV clinic's essential procedures. This example of task shifting may also be applicable to the diagnosis of other cancers (e.g., breast) in resource-limited settings.

  4. A small punch test technique for characterizing the elastic modulus and fracture behavior of PMMA bone cement used in total joint replacement.

    Science.gov (United States)

    Giddings, V L; Kurtz, S M; Jewett, C W; Foulds, J R; Edidin, A A

    2001-07-01

    Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.

  5. Diagnostic validity Polish language version of the questionnaire MINI-KID (Mini International Neuropsychiatry Interview for Children and Adolescent).

    Science.gov (United States)

    Adamowska, Sylwia; Sylwia, Adamowska; Adamowski, Tomasz; Tomasz, Adamowski; Frydecka, Dorota; Dorota, Frydecka; Kiejna, Andrzej; Andrzej, Kiejna

    2014-10-01

    Since over forty years structuralized interviews for clinical and epidemiological research in child and adolescent psychiatry are being developed that should increase validity and reliability of diagnoses according to classification systems (DSM and ICD). The aim of the study is to assess the validity of the Polish version of MINI-KID (Mini International Neuropsychiatric Interview for Children and Adolescents) in comparison to clinical diagnosis made by a specialist in the field of child and adolescent psychiatry. There were 140 patients included in the study (93 boys, 66.4%, mean age 11.8±3.0 and 47 girls 33.5%, mean age 14.0±2.9). All the patients were diagnosed by the specialist in the field of child and adolescent psychiatry according to ICD-10 criteria and by the independent interviewer with the Polish version of MINI-KID (version 2.0, 2001). There was higher agreement between clinical diagnoses and diagnoses based on MINI-KID interview with respect to eating disorders and externalizing disorders (κ 0.43-0.56) and lower in internalizing disorders (κ 0.13-0.45). In the clinical interview, there was smaller number of diagnostic categories (maximum 3 diagnoses per one patient) in comparison to MINI-KID (maximum 10 diagnoses per one patient), and the smaller percentage of patients with one diagnosis (65,7%) in comparison to MINI-KID interview (72%). Our study has shown satisfactory validity parameters of MINI-KID questionnaire, promoting its use for clinical and epidemiological settings. The Mini International Neuropsychiatry Interview for Children and Adolescent (MINI-KID) is the first structuralized diagnostic interview for assessing mental status in children and adolescents, which has been translated into Polish language. Our validation study demonstrated satisfactory psychometric properties of the questionnaire, enabling its use in clinical practice and in research projects. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Mini-Sniffer on Lakebed

    Science.gov (United States)

    1974-01-01

    The original Mini-Sniffer on Rogers Dry Lake, adjacent to NASA's Flight Research Center, Edwards AFB. This version of the remotely-piloted vehicle had swept-back wings, tip rudders, nose canards, and an air breathing engine. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  7. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  8. Estimation of ductility of Fe-Al alloys by means of small punch test

    Czech Academy of Sciences Publication Activity Database

    Dobeš, Ferdinand; Milička, Karel

    Roč.18, č.7 (2010), s. 1357-1359 ISSN 0966-9795. [Discussion Meeting on the Development of Innovative Iron Aluminium Alloys /5./. Praha, 21.09.2009-24.09.2009] R&D Projects: GA ČR GA106/08/1238 Institutional research plan: CEZ:AV0Z20410507 Keywords : iron aluminides * brittleness * small punch test Subject RIV: JG - Metallurgy Impact factor: 2.327, year: 2010

  9. Tumescent mastectomy technique in autologous breast reconstruction.

    Science.gov (United States)

    Vargas, Christina R; Koolen, Pieter G L; Ho, Olivia A; Ricci, Joseph A; Tobias, Adam M; Lin, Samuel J; Lee, Bernard T

    2015-10-01

    Use of the tumescent mastectomy technique has been reported to facilitate development of a hydrodissection plane, reduce blood loss, and provide adjunct analgesia. Previous studies suggest that tumescent dissection may contribute to adverse outcomes after immediate implant reconstruction; however, its effect on autologous microsurgical reconstruction has not been established. A retrospective review was conducted of all immediate microsurgical breast reconstruction procedures at a single academic center between January 2004 and December 2013. Records were queried for age, body mass index, mastectomy weight, diabetes, hypertension, smoking, preoperative radiation, reconstruction flap type, and autologous flap weight. Outcomes of interest were mastectomy skin necrosis, complete and partial flap loss, return to the operating room, breast hematoma, seroma, and infection. There were 730 immediate autologous breast reconstructions performed during the study period; 46% with the tumescent dissection technique. Groups were similar with respect to baseline patient and procedural characteristics. Univariate analysis revealed no significant difference in the incidence of mastectomy skin necrosis, complete or partial flap loss, return to the operating room, operative time, estimated blood loss, recurrence, breast hematoma, seroma, or infection in patients undergoing tumescent mastectomy. Multivariate analysis also demonstrated no significant association between the use of tumescent technique and postoperative breast mastectomy skin necrosis (P = 0.980), hematoma (P = 0.759), or seroma (P = 0.340). Use of the tumescent dissection technique during mastectomy is not significantly associated with adverse outcomes after microsurgical breast reconstruction. Despite concern for its impact on implant reconstruction, our findings suggest that this method can be used safely preceding autologous procedures. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The Individual Features Of Indonesian-Chinese Mini-Novels

    Directory of Open Access Journals (Sweden)

    Ma Feng

    2011-11-01

    Full Text Available This article talks about mini-novels in the new period of Indonesian Chinese Literature. Through the overall developing trend of mini-novels’ corpuses, analyzes the individual creative features: firstly, the humor of Mo Mingmiao’s Mini-novels; secondly, the compassion of Xiao Xing’s Mini-novels; thirdly, Yuan Ni’s emotional sonata of The Lost Key-ring. By combination of themes and techniques of the three mini-novels corpuses, the article focuses on the analysis of three writers’ distinctive writing style.

  11. Mini-Sniffer II in Flight

    Science.gov (United States)

    1976-01-01

    This photograph shows the second Mini-Sniffer undergoing flight testing over Rogers Dry Lake in Edwards, California. This version of the Mini-Sniffer lacked the canard of the original version and had wing tips and tail booms added. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  12. Perinatal outcomes after gestational surrogacy versus autologous IVF: analysis of national data.

    Science.gov (United States)

    Sunkara, Sesh Kamal; Antonisamy, Belavendra; Selliah, Hepsy Y; Kamath, Mohan S

    2017-12-01

    Anonymized data were obtained from the Human Fertilization and Embryology Authority to determine whether gestational surrogacy influences perinatal outcomes compared with pregnancies after autologous IVF. A total of 103,160 singleton live births, including 244 after gestational surrogacy, 87,571 after autologous fresh IVF and intractyoplasmic sperm injection (ICSI) and 15,345 after autologous frozen embryo transfers were analysed. Perinatal outcomes of pretern birth (PTB), low birth weight (LBW) and high birth weight (HBW) were compared. No difference was found in the risk of PTB and LBW after gestational surrogacy compared with autologous fresh IVF-ICSI: PTB (adjusted OR 0.90, 95% CI 0.56 to 1.42), LBW (adjusted OR 0.90, 95% CI 0.57 to 1.43) and gestational surrogacy compared with autologous frozen embryo transfers: PTB (adjusted OR 0.96, 95% CI 0.58 to 1.60), LBW (adjusted OR 1.16, 95% CI 0.69 to 1.96). The incidence of HBW was significantly higher after gestational surrogacy compared with fresh IVF-ICSI (adjusted OR 1.94, 95% CI 1.38 to 2.75); no difference was found in HBW between gestational surrogacy and autologous frozen embryo transfers. The dataset is limited by lack of information on confounders, i.e. ethnicity, body mass index, underlying medical history, which could result in residual confounding. Copyright © 2017 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Current Status of the MiniBooNE Experiment

    OpenAIRE

    Ray, H.; collaboration, for the MiniBooNE

    2004-01-01

    MiniBooNE is an experiment designed to refute or confirm the LSND anti-nu_mu -> anti-nu_e oscillation result. MiniBooNE will look for oscillations of nu_mu -> nu_e in a closed-box appearance analysis. MiniBooNE began collecting data in 2002, and is expected to continue data taking through 2005. Current MiniBooNE results are presented.

  14. Autologous tenocyte therapy for experimental Achilles tendinopathy in a rabbit model.

    Science.gov (United States)

    Chen, Jimin; Yu, Qian; Wu, Bing; Lin, Zhen; Pavlos, Nathan J; Xu, Jiake; Ouyang, Hongwei; Wang, Allan; Zheng, Ming H

    2011-08-01

    Tendinopathy of the Achilles tendon is a chronic degenerative condition that frequently does not respond to treatment. In the current study, we propose that autologous tenocytes therapy (ATT) is effective in treating tendon degeneration in a collagenase-induced rabbit Achilles tendinopathy model. Chronic tendinopathy was created in the left Achilles tendon of 44 rabbits by an intratendonous injection of type I collagenase. Forty-two rabbits were randomly allocated into three groups of 14 and received control treatment; autologous tenocytes digested from tendon tissue; and autologous tenocytes digested from epitendineum tissue. For cell tracking in vivo, the remaining two animals were injected with autologous tenocytes labeled with a nano-scale super-paramagnetic iron oxide (Feridex). Rabbits were sacrificed at 4 and 8 weeks after the therapeutic injection, and tendon tissue was analyzed by histology, immunostaining, and biomechanical testing to evaluate tissue repair. Autologous tenocyte treatment improved tendon remodeling, histological outcomes, collagen content, and tensile strength of tendinopathic Achilles tendons. Injected tenocytes were integrated into tendon matrix and could be tracked up to 8 weeks in vivo. Immunohistochemistry showed that ATT improved type I collagen expression in repaired tendon but did not affect type III collagen and secreted protein, acidic and rich in cysteine expression. ATT may be a useful treatment of chronic Achilles tendinopathy.

  15. LOCAL CORTICOSTEROID VS. AUTOLOGOUS BLOOD FOR PLANTAR FASCIITIS

    Directory of Open Access Journals (Sweden)

    Syam Sunder B

    2017-01-01

    Full Text Available BACKGROUND Plantar fasciitis is the most common cause of heel pain for which professional care is sought. Initially thought of as an inflammatory process, plantar fasciitis is a disorder of degenerative changes in the fascia and maybe more accurately termed plantar fasciosis. Traditional therapeutic efforts have been directed at decreasing the presumed inflammation. These treatments include icing, Nonsteroidal Anti-inflammatory Drugs (NSAIDs, rest and activity modification, corticosteroids, botulinum toxin type A, splinting, shoe modifications and orthosis. Other treatment techniques have been directed at resolving the degeneration caused by the disease process. In general, these techniques are designed to create an acute inflammatory reaction with the goal of restarting the healing process. These techniques include autologous blood injection, Platelet-Rich Plasma (PRP injection, nitroglycerin patches, Extracorporeal Shock Wave Therapy (ESWT and surgical procedures. Recently, research has focused on regenerative therapies with high expectations of success. The use of autologous growth factors is thought to heal through collagen regeneration and the stimulation of a well-ordered angiogenesis. These growth factors are administered in the form of autologous whole blood or Platelet-Rich Plasma (PRP. Platelets can be isolated using simple cell-separating systems. The degranulation of the alpha granules in the platelets releases many different growth factors that play a role in tissue regeneration processes. Platelet-derived growth factor, transforming growth factor-P, vascular-derived endothelial growth factor, epithelial growth factor, hepatocyte growth factor and insulin-like growth factor are examples of such growth factors. Injections with autologous growth factors are becoming common in clinical practice. The present study was an attempt to compare the efficacy of autologous blood injection in plantar fasciitis by comparing it with the local

  16. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, Ian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burman, Kari [National Renewable Energy Lab. (NREL), Golden, CO (United States); Singh, Mohit [National Renewable Energy Lab. (NREL), Golden, CO (United States); Esterly, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mutiso, Rose [US Department of Energy, Washington, DC (United States); McGregor, Caroline [US Department of Energy, Washington, DC (United States)

    2016-11-01

    Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that

  17. Hot embossing and mechanical punching of biodegradable microcontainers for oral drug delivery

    DEFF Research Database (Denmark)

    Petersen, Ritika Singh; Mahshid, Rasoul; Andersen, Nis Korsgaard

    2015-01-01

    A process has been developed to fabricate discrete three-dimensional microcontainers for oral drug delivery application in Poly-L-Lactic Acid (PLLA) polymer. The method combines hot embossing for the definition of holes in a PLLA film and mechanical punching to penetrate the polymer layer around...... and shapes of microcontainers. Finally, the process is compatible with roll-to-roll processing that could lead to low cost high volume production. © 2014 Elsevier B.V. All rights reserved....

  18. Model Documentation for the MiniCAM

    Energy Technology Data Exchange (ETDEWEB)

    Brenkert, Antoinette L.; Smith, Steven J.; Kim, Son H.; Pitcher, Hugh M.

    2003-07-17

    The MiniCAM, short for the Mini-Climate Assessment Model, is an integrated assessment model of moderate complexity focused on energy and agriculture sectors. The model produces emissions of greenhouse gases (carbon dioxide, methane and nitrous oxide) and other radiatively important substances such as sulfur dioxide. Through incorporation of the simple climate model MAGICC, the consequences of these emissions for climate change and sea-level rise can be examined. The MiniCAM is designed to be fast and flexible.

  19. Effectiveness of autologous transfusion system in primary total hip and knee arthroplasty.

    LENUS (Irish Health Repository)

    Schneider, Marco M

    2014-01-01

    Autologous transfusion has become a cost-efficient and useful option in the treatment of patients with high blood loss following major orthopaedic surgery. However, the effectiveness of autologous transfusion in total joint replacement remains controversial.

  20. Influence of the column rectangularity index and of the boundary conditions in the punching resistance of slab-column connections

    Directory of Open Access Journals (Sweden)

    O. S. PAIVA

    Full Text Available Experimental evidence indicates that both the column rectangularity index and the boundary conditions of the connection may affect the ultimate punching resistance. This paper presents general aspects of these topics and, through the analysis of experimental results of tests on 131 slabs, evaluates the accuracy and suitability of recommendations presented by ABNT NBR 6118, Eurocode 2, ACI 318 and fib Model Code 2010. Experimental results showed that the security level of normative estimates trend to reduce as the column rectangularity increases, and in some cases, the punching resistance was overestimated. Finally, adjustments are suggested in equations presented by NBR 6118 and MC2010 in order to eliminate this trend of unsafe results.

  1. Movimentação de molares inferiores ancorados em mini-parafusos Mandibular molar uprighting, using mini-screw as anchorage

    Directory of Open Access Journals (Sweden)

    Rosana Canteras Di Matteo

    2005-08-01

    Full Text Available Freqüentemente a movimentação ortodôntica exige recursos adicionais de ancoragem. Os mini-parafusos têm-se apresentado como uma possível solução. O propósito deste trabalho foi estabelecer um método para a verticalização de molares inferiores inclinados para mesial, utilizando ancoragem em mini-parafusos colocados na região de linha oblíqüa externa da mandíbula. Foram selecionados três pacientes entre 40 a 48 anos (dois do gênero feminino, um do gênero masculino, com molares inferiores inclinados para mesial e distalmente posicionados às áreas edêntulas. Os pacientes foram tratados ortodonticamente durante um período de 6 a 12 meses, com técnica ortodôntica MD3. Mini-parafusos de titânio foram colocados bilateralmente com anestesia local. Uma incisão sobre a linha oblíqüa externa da mandíbula, medindo aproximadamente 1 cm foi realizada em cada lado, distalmente aos molares inclinados. Após descolamento muco-periosteal, mini-parafusos foram implantados e foram realizadas suturas deixando suas cabeças exteriorizadas. Uma semana após a remoção das suturas, cargas ortodônticas (entre 150 a 200 gramas/força foram aplicadas através de forças elásticas. Verificamos que alguma inflamação foi observada ao redor dos mini-parafusos, mas foi controlada com procedimentos de higienização. O procedimento cirúrgico é simples, podendo ser realizado pelo ortodontista; as formas dimensionais dos mini-parafusos são adequadas e estes são de fácil remoção após uso. Concluímos que o uso de mini-parafusos representa uma alternativa efetiva de ancoragem ortodôntica na verticalização de molares inferiores.Tooth movement frequently requires additional anchorage resources. Mini-screws have been used as a possible solution to this matter. The purpose of this study was to establish a method of mandibular molar uprighting, using mini-screw as anchorage, positioned on the mandibular external oblique line, behind and

  2. Standardization of the Korean version of Mini-Mental Adjustment to Cancer (K-Mini-MAC) scale: factor structure, reliability and validity.

    Science.gov (United States)

    Kang, Jee In; Chung, Hyun Cheol; Kim, Se Joo; Choi, Hye Jin; Ahn, Joong Bae; Jeung, Hei-Cheul; Namkoong, Kee

    2008-06-01

    Mental adjustment and coping affect the physical outcome and survival as well as quality of life in cancer patients. The Mini-Mental Adjustment to Cancer (Mini-MAC) scale is a new refined, economical and reliable self-rating instrument measuring cognitive and behavioral responses to cancer. The aim of this study was to evaluate the psychometric properties of the Mini-MAC in Korean cancer patients. A total of 208 cancer patients recruited from the Yonsei Cancer Center were assessed with the Mini-MAC and the Hospital Anxiety and Depression Scale (HADS). Principal component analysis with varimax rotation for the Korean version of Mini-MAC (K-Mini-MAC) confirmed four factors. Three had psychometric properties similar to Helpless-Hopeless (HH), Anxious Preoccupation (AP) and Cognitive Avoidance (CA) of the original Mini-MAC. A novel factor, named Positive Attitude, included items of both Fatalism (FA) and Fighting Spirit (FS) from the original version. The five subscales from the original version (AP, HH, FS, FA and CA) and Positive Attitude had acceptable internal reliabilities in our sample (Cronbach's alpha coefficient 0.50-0.86; correlation coefficient of test-retest 0.68-0.88). For the validity, significant interscale correlation was observed in the original five subscales and Positive Attitude. Each subscale including Positive Attitude was also significantly related to Depression and Anxiety of HADS. As a whole, the K-Mini-MAC was a reliable, valid and acceptable tool for Korean cancer patients. These findings can provide information about the cross-cultural validity of Mini-MAC scale's factor structure. Cultural differences were also discussed.

  3. Autologous serum therapy in chronic urticaria

    Directory of Open Access Journals (Sweden)

    Sharmila Patil

    2013-01-01

    Full Text Available Autologous serum therapy is a promising therapy for treatment resistant urticaria. This is useful in developing countries as this is economical option. Minimum instruments like centrifuge, syringe and needles are required for the procedure.

  4. Book review: Introduction to Social Research: Quantitative and Qualitative Approaches, Third Edition, by Keith F Punch

    NARCIS (Netherlands)

    Lecheler, S.

    2014-01-01

    In Introduction to Social Research, Keith F. Punch wants to ‘demystify’ and ‘simplify’ the research process, in an attempt to show that quality research can always be achieved. With its straightforward language, an intuitive structure, and well-defined learning objectives, this book does just that,

  5. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Esterly, Sean; Baring-Gould, Ian; Booth, Samuel

    2017-05-04

    To address the root challenges of providing quality power to remote consumers through financially viable mini-grids, the Global Lighting and Energy Access Partnership (Global LEAP) initiative of the Clean Energy Ministerial and the U.S. Department of Energy teamed with the National Renewable Energy Laboratory (NREL) and Power Africa to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The framework addresses both alternating current (AC) and direct current (DC) mini-grids, and is applicable to renewable, fossil-fuel, and hybrid systems.

  6. Autologous Hematopoietic Stem Cell Transplantation to Prevent Antibody Mediated Rejection After Vascularized Composite Allotransplantation

    Science.gov (United States)

    2017-10-01

    Award Number: W81XWH-16-1-0664 TITLE: Autologous Hematopoietic Stem Cell Transplantation to Prevent Antibody-Mediated Rejection after...Annual 3. DATES COVERED 15 Sep 2016 – 14 Sep 2017 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Autologous Hematopoietic Stem Cell Transplantation to...sensitization, autologous hematopoietic stem cell transplantation, antibody mediated rejection, donor specific antibodies 16. SECURITY CLASSIFICATION OF

  7. The Psychometrics of the Mini-K.

    Science.gov (United States)

    Richardson, George B; Chen, Ching-Chen; Dai, Chia-Liang; Brubaker, Michael D; Nedelec, Joseph L

    2017-01-01

    Many published studies have employed the Mini-K to measure a single fast-slow life history dimension. However, the internal structure of the Mini-K has not been determined and it is not clear that a single higher order K-factor fits the data. It is also not clear that the Mini-K is measurement invariant across groups such as the sexes. To establish the construct validity of K as well as the broader usefulness of applying life history theory to humans, it is crucial that these psychometric issues are addressed as a part of measure validation efforts. Here we report on three studies that used latent variable modeling and data drawn from two college student samples ( ns = 361 and 300) to elucidate the psychometrics of the Mini-K. We found that (a) the Mini-K had a six dimensional first-order structure, (b) the K-factor provided a parsimonious explanation of the associations among the lower order factors at no significant cost to fit, (c) the Mini-K measured the same K-factor across the sexes, (d) K-factor means did not have the same meaning across the sexes and thus the first-order factors should be used in studies of mean sex differences, and finally, (e) the K-factor was only associated with environment and aspects of mating competition in females. Implications and future directions for life history research are discussed.

  8. Regeneration of Cartilage in Human Knee Osteoarthritis with Autologous Adipose Tissue-Derived Stem Cells and Autologous Extracellular Matrix

    Directory of Open Access Journals (Sweden)

    Jaewoo Pak

    2016-08-01

    Full Text Available This clinical case series demonstrates that percutaneous injections of autologous adipose tissue-derived stem cells (ADSCs and homogenized extracellular matrix (ECM in the form of adipose stromal vascular fraction (SVF, along with hyaluronic acid (HA and platelet-rich plasma (PRP activated by calcium chloride, could regenerate cartilage-like tissue in human knee osteoarthritis (OA patients. Autologous lipoaspirates were obtained from adipose tissue of the abdominal origin. Afterward, the lipoaspirates were minced to homogenize the ECM. These homogenized lipoaspirates were then mixed with collagenase and incubated. The resulting mixture of ADSCs and ECM in the form of SVF was injected, along with HA and PRP activated by calcium chloride, into knees of three Korean patients with OA. The same affected knees were reinjected weekly with additional PRP activated by calcium chloride for 3 weeks. Pretreatment and post-treatment magnetic resonance imaging (MRI data, functional rating index, range of motion (ROM, and pain score data were then analyzed. All patients' MRI data showed cartilage-like tissue regeneration. Along with MRI evidence, the measured physical therapy outcomes in terms of ROM, subjective pain, and functional status were all improved. This study demonstrates that percutaneous injection of ADSCs with ECM contained in autologous adipose SVF, in conjunction with HA and PRP activated by calcium chloride, is a safe and potentially effective minimally invasive therapy for OA of human knees.

  9. Treatment of Refractory Filamentary Keratitis With Autologous Serum Tears.

    Science.gov (United States)

    Read, Sarah P; Rodriguez, Marianeli; Dubovy, Sander; Karp, Carol L; Galor, Anat

    2017-09-01

    To report a case of filamentary keratitis (FK) successfully treated with autologous serum tears and to review the pathogenesis and management of FK. Case report including high-resolution anterior segment optical coherence tomography and filament histopathology. A 61-year-old Hispanic man presented with pain and photophobia of the right eye. He was found to have a corneal epithelial defect and a small peripheral infiltrate 4 months after Laser Assisted in situ Keratomileusis. After resolution of the epithelial defect, he developed FK. Over a 4-month period, conservative management with aggressive lubrication, lid hygiene, topical corticosteroids, topical cyclosporine, bandage contact lenses, and oral doxycycline failed to resolve the corneal filaments. Notably, treatment with 20% autologous serum tears, four times daily, led to a sustained resolution of the FK within 1 week. This case demonstrates the complexity of FK management and introduces autologous serum tears as a viable management option when conservative approaches to this condition fail.

  10. Delamination measurement of a laminates composite panel due to hole punching based on the focus variation technique

    Science.gov (United States)

    Abdullah, A. B.; Zain, M. S. M.; Abdullah, M. S.; Samad, Z.

    2017-07-01

    Structural materials, such as composite panels, must be assembled, and such panels are typically constructed via the insertion of a fastener through a drilled hole. The main problem encountered in drilling is delamination, which affects assembly strength. The cost of drilling is also high because of the severe wear on drill bits. The main goal of this research is to develop a new punching method as an alternative to drilling during hole preparation. In this study, the main objective is to investigate the effect of different puncher profiles on the quality of holes punched into carbon fiber reinforcement polymer (CFRP) composite panels. Six types of puncher profiles were fabricated with minimum die clearance (1%), and two quality aspects, namely, incomplete shearing and delamination factor, were measured. The conical puncher incurred the least defects in terms of delamination and yielded an acceptable amount of incomplete shearing in comparison with the other punchers.

  11. Mini-Membrane Evaporator for Contingency Spacesuit Cooling

    Science.gov (United States)

    Makinen, Janice V.; Bue, Grant C.; Campbell, Colin; Petty, Brian; Craft, Jesse; Lynch, William; Wilkes, Robert; Vogel, Matthew

    2015-01-01

    The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only approximately 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini-ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

  12. Strain gradient effects in periodic flat punch indenting at small scales

    DEFF Research Database (Denmark)

    Nielsen, Kim Lau; Niordson, Christian Frithiof; Hutchinson, J. W.

    2014-01-01

    Experiments on soft polycrystalline aluminum have yielded evidence that, besides the required punch load, both the size and shape of imprinted features are affected by the scale of the set-up, e.g. substantial details are lost when the characteristic length is on the order of 10μm. The objective...... are employed. During a largely non-homogeneous deformation, the material is forced up in between the indenters so that an array of identical imprinted features is formed once the tool is retreated. It is confirmed that the additional hardening owing to plastic strain gradients severely affects both the size...

  13. Tensile properties of modified 9Cr-1Mo steel by shear punch testing and correlation with microstructures

    Energy Technology Data Exchange (ETDEWEB)

    Karthik, V., E-mail: karthik@igcar.gov.in [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamil Nadu 603102 (India); Laha, K.; Parameswaran, P.; Chandravathi, K.S.; Kasiviswanathan, K.V.; Jayakumar, T.; Raj, Baldev [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamil Nadu 603102 (India)

    2011-10-15

    Modified 9Cr-1Mo ferritic steel (P91) is subjected to a series of heat treatments consisting of soaking for 5 min at the selected temperatures in the range 973 K-1623 K (below Ac{sub 1} to above Ac{sub 4}) followed by oil quenching and tempering at 1033 K for 1 h to obtain different microstructural conditions. The tensile properties of the different microstructural conditions are evaluated from small volumes of material by shear punch test technique. A new methodology for evaluating yield strength, ultimate tensile strength and strain hardening exponent from shear punch test by using correlation equations without employing empirical constants is presented and validated. The changes in the tensile properties are related to the microstructural changes of the steel investigated by electron microscopic studies. The steel exhibits minimum strength and hardness when soaked between Ac{sub 1} and Ac{sub 3} (intercritical range) temperatures due to the replacement of original lath martensitic structure with subgrains. The finer martensitic microstructure produced in the steel after soaking at temperatures above Ac{sub 3} leads to a monotonic increase in hardness and strength with decreasing strain hardening exponent. For soaking temperatures above Ac{sub 4}, the hardness and strength of the steel increases marginally due to the formation of soft {delta} ferrite. - Highlights: > A methodology presented for computing tensile properties from shear punch test. > UTS and strain hardening estimated using extended analysis of blanking models. > The analysis methodology validated for different heat treated 9Cr-1Mo steel. > Changes in tensile properties of steel correlated with microstructures.

  14. Demonstration of the self-magnetic-pinch diode as an X-ray source for flash core-punch radiography

    International Nuclear Information System (INIS)

    Cordova, Steve Ray; Rovang, Dean Curtis; Portillo, Salvador; Oliver, Bryan Velten; Bruner, Nichelle Lee; Ziska, Derek Raymond

    2007-01-01

    Minimization of the radiographic spot size and maximization of the radiation dose is a continuing long-range goal for development of electron beam driven X-ray radiography sources. In collaboration with members of the Atomic Weapons Establishment(AWE), Aldermaston UK, the Advanced Radiographic Technologies Dept. 1645 is conducting research on the development of X-ray sources for flash core-punch radiography. The Hydrodynamics Dept. at AWE has defined a near term radiographic source requirement for scaled core-punch experiments to be 250 rads(at)m with a 2.75 mm source spot-size. As part of this collaborative effort, Dept. 1645 is investigating the potential of the Self-Magnetic-Pinched (SMP) diode as a source for core-punch radiography. Recent experiments conducted on the RITS-6 accelerator [1,2] demonstrated the potential of the SMP diode by meeting and exceeding the near term radiographic requirements established by AWE. During the demonstration experiments, RITS-6 was configured with a low-impedance (40 (Omega)) Magnetically Insulated Transmission Line (MITL), which provided a 75-ns, 180-kA, 7.5-MeV forward going electrical pulse to the diode. The use of a low-impedance MITL enabled greater power coupling to the SMP diode and thus allowed for increased radiation output. In addition to reconfiguring the driver (accelerator), geometric changes to the diode were also performed which allowed for an increase in dose production without sacrificing the time integrated spot characteristics. The combination of changes to both the pulsed power driver and the diode significantly increased the source x-ray intensity

  15. MINI-THESAURUS, Energy Data Base Subject Thesaurus Generator

    International Nuclear Information System (INIS)

    Paulk, J.W.

    2003-01-01

    1 - Description of program or function: MINI-THESAURUS allows the user to subset into highly-specialized 'mini-thesauri' the Energy Data Base (EDB) Subject Thesaurus, which contains the standard vocabulary of indexing terms (descriptors) developed and structured by the Office of Scientific and Technical Information (OSTI) for the building and maintenance of the U.S. Department of Energy (DOE) energy information databases. This structured vocabulary reflects the scope of DOE's research, development, and technological programs and encompasses terminology derived not only from the basic sciences but also from the areas of energy, conservation, safety, environmental impact, and regulation. Entire word blocks may be copied from the primary Subject Thesaurus, from another mini-thesaurus, or both, and subsequently modified through the addition of new terms, the deletion of existing terms, and changes to the internal relationships among the word blocks within the mini-thesaurus to create a new, special-purpose thesaurus. MINI-THESAURUS also provides the ability to copy the entire Subject Thesaurus and to treat the copy as a mini-thesaurus, thus allowing one to examine the effects of major changes to the thesaurus structure without having to modify the primary, on-line Thesaurus. The copy operation also optimizes the Subject Thesaurus structure. An interactive user having update privileges for a specific mini-thesaurus and access to the TeX and PostScript proprietary software can produce the mini-thesaurus in printed publication format. Once the mini-thesaurus has been published, periodic supplements may be generated based on date of entry or change maintained by the Thesaurus software. 2 Restrictions on the complexity of the problem: The system enforces the OSTI rules for Thesaurus development

  16. Punch grafts to treat lower limb intractable sores

    Directory of Open Access Journals (Sweden)

    JÚLIO WILSON FERNANDES

    Full Text Available ABSTRACT Lower limb recurrent ulcers, usually caused by prolonged decubitus, trauma, diabetes or burns, may not heal with conventional clinical or surgical treatment. Frequently, laminated skin grafts do not integrate with the recipient layer, and the only alternatives are neighbor microsurgical flaps. These have higher morbidity and create secondary defects, to be corrected with skin grafts, when fasciocutaneous or miocutaneous segments are removed for the treatment of the primary defect. We describe the non-conventional use of punch grafts in the treatment of lower limb ulcers, when conventional skin laminated graft failed, without the use of flaps. Since this is a very successful technique, its use should be considered as a valuable alternative for the treatment of recurrent lower limb ulcers. It is a simple and easy-learned technique that may be used by different surgeons, even in remote places without correct specialized hospital facilities.

  17. Spurious RF signals emitted by mini-UAVs

    Science.gov (United States)

    Schleijpen, Ric (H. M. A.); Voogt, Vincent; Zwamborn, Peter; van den Oever, Jaap

    2016-10-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to the sensor community. The detection, classification and identification chain can take advantage of different sensor technologies. Apart from the signatures used by radar and electro-optical sensor systems, the UAV also emits RF signals. These RF signatures can be split in intentional signals for communication with the operator and un-intentional RF signals emitted by the UAV. These unintentional or spurious RF emissions are very weak but could be used to discriminate potential UAV detections from false alarms. The goal of this research was to assess the potential of exploiting spurious emissions in the classification and identification chain of mini-UAVs. It was already known that spurious signals are very weak, but the focus was on the question whether the emission pattern could be correlated to the behaviour of the UAV. In this paper experimental examples of spurious RF emission for different types of mini-UAVs and their correlation with the electronic circuits in the UAVs will be shown

  18. In Vitro Analysis of Cartilage Regeneration Using a Collagen Type I Hydrogel (CaReS) in the Bovine Cartilage Punch Model.

    Science.gov (United States)

    Horbert, Victoria; Xin, Long; Foehr, Peter; Brinkmann, Olaf; Bungartz, Matthias; Burgkart, Rainer H; Graeve, T; Kinne, Raimund W

    2018-02-01

    Objective Limitations of matrix-assisted autologous chondrocyte implantation to regenerate functional hyaline cartilage demand a better understanding of the underlying cellular/molecular processes. Thus, the regenerative capacity of a clinically approved hydrogel collagen type I implant was tested in a standardized bovine cartilage punch model. Methods Cartilage rings (outer diameter 6 mm; inner defect diameter 2 mm) were prepared from the bovine trochlear groove. Collagen implants (± bovine chondrocytes) were placed inside the cartilage rings and cultured up to 12 weeks. Cartilage-implant constructs were analyzed by histology (hematoxylin/eosin; safranin O), immunohistology (aggrecan, collagens 1 and 2), and for protein content, RNA expression, and implant push-out force. Results Cartilage-implant constructs revealed vital morphology, preserved matrix integrity throughout culture, progressive, but slight proteoglycan loss from the "host" cartilage or its surface and decreasing proteoglycan release into the culture supernatant. In contrast, collagen 2 and 1 content of cartilage and cartilage-implant interface was approximately constant over time. Cell-free and cell-loaded implants showed (1) cell migration onto/into the implant, (2) progressive deposition of aggrecan and constant levels of collagens 1 and 2, (3) progressively increased mRNA levels for aggrecan and collagen 2, and (4) significantly augmented push-out forces over time. Cell-loaded implants displayed a significantly earlier and more long-lasting deposition of aggrecan, as well as tendentially higher push-out forces. Conclusion Preserved tissue integrity and progressively increasing cartilage differentiation and push-out forces for up to 12 weeks of cultivation suggest initial cartilage regeneration and lateral bonding of the implant in this in vitro model for cartilage replacement materials.

  19. Screening for autologous blood transfusions

    DEFF Research Database (Denmark)

    Mørkeberg, J; Belhage, B; Ashenden, M

    2009-01-01

    parameter in the screening for autologous blood doping. Three bags of blood (approximately 201+/-11 g of Hb) were withdrawn from 16 males and stored at either -80 degrees C (-80 T, n=8) or +4 degrees C (+4 T, n=8) and reinfused 10 weeks or 4 weeks later, respectively. Seven subjects served as controls...

  20. Autologous blood transfusion in open heart surgeries under cardio-pulmonary bypass - Clinical appraisal

    Directory of Open Access Journals (Sweden)

    B. Sartaj Hussain

    2017-01-01

    Full Text Available Autologous blood withdrawal before instituting cardiopulmonary bypass (CPB protects the platelets, preserve red cell mass and reduce allogeneic transfusion requirements. Ideal condition for autologous blood donation is elective cardiac surgery where there is a high probability of blood transfusion. The purpose of this study was to assess the role of preoperative autologous blood donation in cardiac surgeries. Out of 150 patients registered, 50 cases were excluded on the basis of hemoglobin content ( [J Med Allied Sci 2017; 7(1.000: 48-54

  1. Mini-Sniffer III on Lakebed

    Science.gov (United States)

    1976-01-01

    The third remotely-piloted Mini-Sniffer research vehicle rests on the lakebed adjacent to the Dryden Flight Research Center, Edwards, California. This view shows the wing shape, hydrazine engine, and the tail booms. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  2. Feasibility of mini-tablets as a flexible drug delivery tool.

    Science.gov (United States)

    Mitra, Biplob; Chang, Jessica; Wu, Sy-Juen; Wolfe, Chad N; Ternik, Robert L; Gunter, Thomas Z; Victor, Michael C

    2017-06-15

    Mini-tablets have potential applications as a flexible drug delivery tool in addition to their generally perceived use as multi-particulates. That is, mini-tablets could provide flexibility in dose finding studies and/or allow for combination therapies in the clinic. Moreover, mini-tablets with well controlled quality attributes could be a prudent choice for administering solid dosage forms as a single unit or composite of multiple mini-tablets in patient populations with swallowing difficulties (e.g., pediatric and geriatric populations). This work demonstrated drug substance particle size and concentration ranges that achieve acceptable mini-tablet quality attributes for use as a single or composite dosage unit. Immediate release and orally disintegrating mini-tablet formulations with 30μm to 350μm (particle size d 90 ) acetaminophen and Compap™ L (90% acetaminophen) at concentrations equivalent to 6.7% and 26.7% acetaminophen were evaluated. Mini-tablets achieved acceptable weight variability, tensile strength, friability, and disintegration time at a reasonable solid fraction for each formulation. The content uniformity was acceptable for mini-tablets of 6.7% formulations with ≤170μm drug substance, mini-tablets of all 26.7% formulations, and composite dosage units containing five or more mini-tablets of any formulation. Results supported the manufacturing feasibility of quality mini-tablets, and their applicability as a flexible drug delivery tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Numerical And Experimental Analysis Of The Process Of Aviation Drawpiece Forming Using Rigid And Rubber Punch With Various Properties

    Directory of Open Access Journals (Sweden)

    Kut S.

    2015-09-01

    Full Text Available This paper presents the results of the numerical analysis and experimental research of the forming process of aviation drawpiece made from 0.6 mm thick Inconel 625 sheet metal. First phase of testing was conducted using rigid steel tools for drawpiece forming. Results of conducted simulations show that during rigid tool forming, the middle of the drawpiece losses stability. In consequence, rigid tool forming leads to the formation of unacceptable wrinkles on the drawpiece. Subsequent experimental research confirmed wrinkles of the metal drawpiece in this area. It was assumed that in order to eliminate this negative phenomenon, minor changes in technology and tool construction would have to be made. The drawpiece will be shaped by means of a flexible tool, than re-shaped using rigid tools. In the second phase of the research, tooling design changes have been made. They consisted of replacing the steel punch with a specially designed stamp susceptible for deformation. FEM numerical simulations were performed for flexible punch forming made of polyurethane elastomer with different hardness (50, 70, 85 and 90 Sh A. On their basis, the effect on the mechanical characteristics of the elastomeric drawing process and the formation of wrinkles was shown. They can be effectively eliminated by the use of a punch with hardness of 90 Sh A, which has also been confirmed by experimental research. In addition, the paper presents a comparative analysis of the deformations in selected actual drawpiece areas and in the elastomeric punch with hardness 90 Sh A computer model. The actual drawpiece deformation schedule and the values were determined using photogrammetric system Argus v.6.3., while the computer modeled drawpiece was based on FEM calculations performed in the MARC / Mentat system. In conclusion the difficulties as well as the advantages and disadvantages in determining the deformation of sheet metal parts were indicated using photogrammetric system

  4. Influence of friction on stress and strain distributions in small punch creep test models

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr; Seitl, Stanislav; Milička, Karel; Dobeš, Ferdinand

    417-418, - (2010), s. 561-564 ISSN 1013-9826. [International Conference on Fracture and Damage Mechanics /8./. Malta, 08.09.2009-10.09.2009] R&D Projects: GA AV ČR(CZ) IAA200410801; GA AV ČR(CZ) 1QS200410502 Institutional research plan: CEZ:AV0Z20410507 Keywords : small punch test * creep * chromium steel * finite element method Subject RIV: JG - Metallurgy www.scientific.net/KEM.417-418.561

  5. Hemifacial atrophy treated with autologous fat transplantation

    Directory of Open Access Journals (Sweden)

    Gandhi Vijay

    2005-01-01

    Full Text Available A 23-year-old male developed right hemifacial atrophy following marphea profunda. Facial asymmetry due to residual atrophy was treated with autologous fat harvested from buttocks with marked cosmetic improvement.

  6. Prospective randomized comparison of scar appearances between cograft of acellular dermal matrix with autologous split-thickness skin and autologous split-thickness skin graft alone for full-thickness skin defects of the extremities.

    Science.gov (United States)

    Yi, Ju Won; Kim, Jae Kwang

    2015-03-01

    The purpose of this study was to evaluate the clinical outcomes of cografting of acellular dermal matrix with autologous split-thickness skin and autologous split-thickness skin graft alone for full-thickness skin defects on the extremities. In this prospective randomized study, 19 consecutive patients with full-thickness skin defects on the extremities following trauma underwent grafting using either cograft of acellular dermal matrix with autologous split-thickness skin graft (nine patients, group A) or autologous split-thickness skin graft alone (10 patients, group B) from June of 2011 to December of 2012. The postoperative evaluations included observation of complications (including graft necrosis, graft detachment, or seroma formation) and Vancouver Scar Scale score. No statistically significant difference was found regarding complications, including graft necrosis, graft detachment, or seroma formation. At week 8, significantly lower Vancouver Scar Scale scores for vascularity, pliability, height, and total score were found in group A compared with group B. At week 12, lower scores for pliability and height and total scores were identified in group A compared with group B. For cases with traumatic full-thickness skin defects on the extremities, a statistically significant better result was achieved with cograft of acellular dermal matrix with autologous split-thickness skin graft than with autologous split-thickness skin graft alone in terms of Vancouver Scar Scale score. Therapeutic, II.

  7. Autologous fat transplantation for depressed linear scleroderma-induced facial atrophic scars.

    Science.gov (United States)

    Roh, Mi Ryung; Jung, Jin Young; Chung, Kee Yang

    2008-12-01

    Facial linear scleroderma results in depressed atrophic scars. Autologous fat transplantation has been widely used, and fat appears to be an ideal material for filling depressed atrophic scars and contour deformities, but long-term results for autologous fat transplantation are controversial. To review the short- and long-term results of 20 patients who underwent multiple autologous fat transplantations for depressed atrophic scar correction. Twenty patients with clinically inactive facial linear scleroderma were included. They received at least two transplantations and had a 12-month follow-up evaluation. On the forehead, 51% to 75% improvement (average grading scale: 2.4) was achieved when observed at least 12 months after the last treatment. For the chin, correction was poor (average grading scale: 0.7) with less than 25% improvement. The infraorbital area showed fair correction, but the nose showed poor correction. Two of three patients with scalp reduction surgery showed excellent results, showing only slight scar widening. Autologous fat transplantation is an effective method for long-term correction of depressed atrophic scars left by linear scleroderma on the forehead but is less effective for corrections on the nose, infraorbital area, and chin.

  8. Use of containers with sterilizing filter in autologous serum eyedrops.

    Science.gov (United States)

    López-García, José S; García-Lozano, Isabel

    2012-11-01

    To assess the effect of the use of containers with an adapted sterilizing filter on the contamination of autologous serum eyedrops. Prospective, consecutive, comparative, and randomized study. Thirty patients with Sjögren syndrome. One hundred seventy-six autologous serum containers used in home therapy were studied; 48 of them included an adapted filter (Hyabak; Thea, Clermont-Ferrand, France), and the other 128 were conventional containers. Containers equipped with a filter were tested at 7, 14, 21, and 28 days of use, whereas conventional containers were studied after 7 days of use. In addition, testing for contamination was carried out in 14 conventional containers used during in-patient therapy every week for 4 weeks. In all cases, the preparation of the autologous serum was similar. Blood agar and chocolate agar were used as regular culture media for the microbiologic studies, whereas Sabouraud agar with chloramphenicol was the medium for fungal studies. Microbiologic contamination of containers with autologous serum eyedrops. Only one of the containers with an adapted sterilizing filter (2.1%) became contaminated with Staphylococcus epidermidis after 1 month of treatment, whereas the contamination rate among conventional containers reached 28.9% after 7 days of treatment. The most frequent germs found in the samples were coagulase-negative Staphylococcus (48.6%). With regard the containers used in the in-patient setting, 2 (14.3%) became contaminated after 2 weeks, 5 (35.7%) became contaminated after 3 weeks, and 5 (50%) became contaminated after 4 weeks, leaving 7 (50%) that did not become contaminated after 1 month of treatment. Using containers with an adapted filter significantly reduces the contamination rates in autologous serum eyedrops, thus extending the use of such container by the patients for up to 4 weeks with virtually no contamination risks. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  9. Mini-marathon groups: psychological "first aid" following disasters.

    Science.gov (United States)

    Terr, L C

    1992-01-01

    Large group counseling sessions for soldiers following battle have been commonly used since World War II. The author conceptualizes and demonstrates how these mini-marathon sessions can be adapted to support all ages and types of civilians involved in disasters. Mini-marathons take about 3 hours and are divided into three sections: story sharing, symptom sharing, and suggestions for self-help, including sharing tales of heroism and survival. After an initial mini-marathon session, a second session may be held emphasizing creativity. The author also describes how mini-marathons can be adapted for therapists who will lead their own sessions.

  10. A clinical study on the feasibility of autologous cord blood transfusion for anemia of prematurity.

    Science.gov (United States)

    Khodabux, Chantal M; von Lindern, Jeannette S; van Hilten, Joost A; Scherjon, Sicco; Walther, Frans J; Brand, Anneke

    2008-08-01

    The objective was to investigate the use of autologous red blood cells (RBCs) derived from umbilical cord blood (UCB), as an alternative for allogeneic transfusions in premature infants admitted to a tertiary neonatal center. UCB collection was performed at deliveries of less than 32 weeks of gestation and processed into autologous RBC products. Premature infants requiring a RBC transfusion were randomly assigned to an autologous or allogeneic product. The primary endpoint was an at least 50 percent reduction in allogeneic transfusion needs. Fifty-seven percent of the collections harvested enough volume (> or =15 mL) for processing. After being processed, autologous products (> or =10 mL/kg) were available for 36 percent of the total study population and for 27 percent of the transfused infants and could cover 58 percent (range, 25%-100%) of the transfusion needs within the 21-day product shelf life. Availability of autologous products depended most on the gestational age. Infants born between 24 and 28 weeks had the lowest availability (17%). All products, however, would be useful in view of their high (87%) transfusion needs. Availability was highest (48%) for the infants born between 28 and 30 weeks. For 42 percent of the infants with transfusion needs in this group, autologous products were available. For the infants born between 30 and 32 weeks, autologous products were available for 36 percent of the infants. Transfusion needs in this group were, however, much lower (19%) compared to the other gestational groups. Autologous RBCs derived from UCB could not replace 50 percent of allogeneic transfusions due to the low UCB volumes collected and subsequent low product availability.

  11. Chimeric Human Skin Substitute Tissue: A Novel Treatment Option for the Delivery of Autologous Keratinocytes.

    Science.gov (United States)

    Rasmussen, Cathy A; Allen-Hoffmann, B Lynn

    2012-04-01

    For patients suffering from catastrophic burns, few treatment options are available. Chimeric coculture of patient-derived autologous cells with a "carrier" cell source of allogeneic keratinocytes has been proposed as a means to address the complex clinical problem of severe skin loss. Currently, autologous keratinocytes are harvested, cultured, and expanded to form graftable epidermal sheets. However, epidermal sheets are thin, are extremely fragile, and do not possess barrier function, which only develops as skin stratifies and matures. Grafting is typically delayed for up to 4 weeks to propagate a sufficient quantity of the patient's cells for application to wound sites. Fully stratified chimeric bioengineered skin substitutes could not only provide immediate wound coverage and restore barrier function, but would simultaneously deliver autologous keratinocytes to wounds. The ideal allogeneic cell source for this application would be an abundant supply of clinically evaluated, nontumorigenic, pathogen-free, human keratinocytes. To evaluate this potential cell-based therapy, mixed populations of a green fluorescent protein-labeled neonatal human keratinocyte cell line (NIKS) and unlabeled primary keratinocytes were used to model the allogeneic and autologous components of chimeric monolayer and organotypic cultures. Relatively few autologous keratinocytes may be required to produce fully stratified chimeric skin substitute tissue substantially composed of autologous keratinocyte-derived regions. The need for few autologous cells interspersed within an allogeneic "carrier" cell population may decrease cell expansion time, reducing the time to patient application. This study provides proof of concept for utilizing NIKS keratinocytes as the allogeneic carrier for the generation of bioengineered chimeric skin substitute tissues capable of providing immediate wound coverage while simultaneously supplying autologous human cells for tissue regeneration.

  12. The use of mini-samples in palaeomagnetism

    Science.gov (United States)

    Böhnel, Harald; Michalk, Daniel; Nowaczyk, Norbert; Naranjo, Gildardo Gonzalez

    2009-10-01

    Rock cores of ~25 mm diameter are widely used in palaeomagnetism. Occasionally smaller diameters have been used as well which represents distinct advantages in terms of throughput, weight of equipment and core collections. How their orientation precision compares to 25 mm cores, however, has not been evaluated in detail before. Here we compare the site mean directions and their statistical parameters for 12 lava flows sampled with 25 mm cores (standard samples, typically 8 cores per site) and with 12 mm drill cores (mini-samples, typically 14 cores per site). The site-mean directions for both sample sizes appear to be indistinguishable in most cases. For the mini-samples, site dispersion parameters k on average are slightly lower than for the standard samples reflecting their larger orienting and measurement errors. Applying the Wilcoxon signed-rank test the probability that k or α95 have the same distribution for both sizes is acceptable only at the 17.4 or 66.3 per cent level, respectively. The larger mini-core numbers per site appears to outweigh the lower k values yielding also slightly smaller confidence limits α95. Further, both k and α95 are less variable for mini-samples than for standard size samples. This is interpreted also to result from the larger number of mini-samples per site, which better averages out the detrimental effect of undetected abnormal remanence directions. Sampling of volcanic rocks with mini-samples therefore does not present a disadvantage in terms of the overall obtainable uncertainty of site mean directions. Apart from this, mini-samples do present clear advantages during the field work, as about twice the number of drill cores can be recovered compared to 25 mm cores, and the sampled rock unit is then more widely covered, which reduces the contribution of natural random errors produced, for example, by fractures, cooling joints, and palaeofield inhomogeneities. Mini-samples may be processed faster in the laboratory, which is of

  13. Autologous blood transfusion in total knee replacement surgery.

    Science.gov (United States)

    Sarkanović, Mirka Lukić; Gvozdenović, Ljiljana; Savić, Dragan; Ilić, Miroslav P; Jovanović, Gordana

    2013-03-01

    Total knee replacement (TKR) surgery is one of the most frequent and the most extensive procedures in orthopedic surgery, accompanied with some serious complications. Perioperative blood loss is one of the most serious losses, so it is vital to recognize and treat such losses properly. Autologous blood transfusion is the only true alternative for the allogeneic blood. The aim of this study was to to examine if autologous blood transfusion reduces usage of allogenic blood in total knee replacement surgery, as well as to examine possible effect of autologous blood transfusion on postoperative complications, recovery and hospital stay of patients after total knee replacement surgery. During the controlled, prospective, randomised study we compared two groups of patients (n = 112) with total prosthesis implanted in their knee. The group I consisted of the patients who received the transfusion of other people's (allogeneic) blood (n = 57) and the group II of the patients whose blood was collected postoperatively and then given them [their own (autologous) blood] (n = 55). The transfusion trigger for both groups was hemoglobin level of 85 g/L. In the group of patients whose blood was collected perioperatively only 9 (0.9%) of the patients received transfusion of allogeneic blood, as opposed to the control group in which 98.24% of the patients received the transfusion of allogeneic blood (p blood was collected stayed in hospital for 6.18 days, while the patients of the control group stayed 7.67 days (p blood transfusion is a very effective method for reducing consumption of allogenic blood and thus, indirectly for reducing all complications related to allogenic blood transfusion. There is also a positive influence on postoperative recovery after total knee replacement surgery due to the reduction of hospital stay, and indirectly on the reduction of hospital costs.

  14. Optimal design of a main driving mechanism for servo punch press based on performance atlases

    Science.gov (United States)

    Zhou, Yanhua; Xie, Fugui; Liu, Xinjun

    2013-09-01

    The servomotor drive turret punch press is attracting more attentions and being developed more intensively due to the advantages of high speed, high accuracy, high flexibility, high productivity, low noise, cleaning and energy saving. To effectively improve the performance and lower the cost, it is necessary to develop new mechanisms and establish corresponding optimal design method with uniform performance indices. A new patented main driving mechanism and a new optimal design method are proposed. In the optimal design, the performance indices, i.e., the local motion/force transmission indices ITI, OTI, good transmission workspace good transmission workspace(GTW) and the global transmission indices GTIs are defined. The non-dimensional normalization method is used to get all feasible solutions in dimensional synthesis. Thereafter, the performance atlases, which can present all possible design solutions, are depicted. As a result, the feasible solution of the mechanism with good motion/force transmission performance is obtained. And the solution can be flexibly adjusted by designer according to the practical design requirements. The proposed mechanism is original, and the presented design method provides a feasible solution to the optimal design of the main driving mechanism for servo punch press.

  15. Heat transfer and pressure drop characteristics of mini-fin structures

    International Nuclear Information System (INIS)

    Jiang Peixue; Xu Ruina

    2007-01-01

    Forced convection heat transfer of air and water in bronze and pure copper mini-fin structures and mini-channel structures was investigated experimentally. The mini-fin dimensions were 0.7 mm x 0.2 mm and 0.8 mm x 0.4 mm. The tests included both staggered diamond-shaped and in-line square mini-fin arrangements. The tests investigated the effects of structures, mini-fin dimensions and arrangement, test section materials, and fluid properties on the convection heat transfer and heat transfer enhancement. For the tested conditions, the convection heat transfer coefficient was increased 9-21 fold for water and 12-38 fold for air in the mini-fin structures compared with an empty plate channel. The friction factor and flow resistance in the mini-channel structures and the in-line square mini-fin arrangement were much less than in the staggered diamond-shaped mini-fin arrangement. For the small channel width, W c = 0.2 mm, the convection heat transfer with the in-line square array structure was more intense than with the staggered diamond-shaped structure, the mini-channel structure or the porous media. For the larger channel width, W c = 0.4 mm, the convection heat transfer in the staggered diamond-shaped array structure was more intense than in the others systems while the in-line square structure had the best overall thermal-hydraulic performance

  16. Contact stresses by rounded punch subject to axial and transverse shear

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kyu [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-05-01

    Contact shear stresses by rounded punch were evaluated numerically. Numerical program was successfully implemented by using an influence function method. To simulate the physical fretting problem, a closed load path of shear was considered. The influence functions on surface displacements fo both axial and transverse direction were calculated using a triangular shear traction element. Behaviour of the contact surface, such as stick and slip region during the load path was investigated together with compliance change. Irreversibility of the shear stress was shown. The importance and the utilization of the present research were discussed for analyzing the material failure induced by contact such as fretting wear and fatigue.

  17. Contact stresses by rounded punch subject to axial and transverse shear

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu

    1999-01-01

    Contact shear stresses by rounded punch were evaluated numerically. Numerical program was successfully implemented by using an influence function method. To simulate the physical fretting problem, a closed load path of shear was considered. The influence functions on surface displacements fo both axial and transverse direction were calculated using a triangular shear traction element. Behaviour of the contact surface, such as stick and slip region during the load path was investigated together with compliance change. Irreversibility of the shear stress was shown. The importance and the utilization of the present research were discussed for analyzing the material failure induced by contact such as fretting wear and fatigue

  18. Quality of intraoperative autologous blood withdrawal used for retransfusion after cardiopulmonary bypass.

    Science.gov (United States)

    Flom-Halvorsen, Hanne I; Øvrum, Eivind; Øystese, Rolf; Brosstad, Frank

    2003-09-01

    Intraoperative autologous blood withdrawal protects the pooled blood from the deleterious effects of cardiopulmonary bypass. Following reinfusion after cardiopulmonary bypass, the fresh autologous blood contributes to less coagulation abnormalities and reduces postoperative bleeding and the need for allogeneic blood products. However, few data have been available concerning the quality and potential activation of fresh blood stored at room temperature in the operating room. Forty coronary artery bypass grafting patients undergoing a consistent intraoperative and postoperative autotransfusion protocol had a median of 1,000 mL of autologous blood withdrawn before cardiopulmonary bypass. After heparinization the blood was drained from the venous catheter via venous cannula into standard blood bags and stored in the operating room until termination of cardiopulmonary bypass. Samples for hemostatic and inflammatory markers were taken from the pooled blood immediately before it was returned to the patient. There was some activation of platelets in the stored autologous blood, as measured by an increase of beta-thromboglobulin. Indications of thrombin formation, as assessed by plasma levels of thrombin-antithrombin complex and prothrombin fragment 1.2 were not seen, and there was no fibrinolytic activity. The red blood cells remained intact, indicated by the absence of plasma free hemoglobin. As for the inflammatory response, the levels of the terminal complement complex remained stable, and the cytokines tumor necrosis factor-alpha and interleukin 6 levels were not increased during storage. The complement activation products increased minimally, but remained within normal ranges. Except for slight activation of platelets, there was no indication of coagulation, hemolysis, fibrinolysis, or immunologic activity in the autologous blood after approximately 1 hour of operating room storage. The autologous blood was preserved in a condition of high quality, and retransfusion

  19. Lymphoscintigraphy and autologous stem cell implantation

    International Nuclear Information System (INIS)

    Peña, Yamile; Batista, Juan F.; Perera, Alejandro; Torres, Leonel A.; Sánchez, Elvia L.; Sánchez, Yolaine; Ducat, Luis; Prats, Anais; Hernández, Porfirio; Romero, Susana; Goicochea, Pedro; Quintela, Ana M.

    2016-01-01

    Lymphoscintigraphy is the criterion standard technique for the diagnosis of lymphedema. Advances of the application of autologous hematopoietic stem cells in ischemic disorders of lower limbs have increased the attention of researchers in this field. Aim: To determine the usefulness of lymphoscintigraphy for the assessment the efficacy of autologous stem cell implantation in patients with chronic lymphedema of the upper and lower limbs. Methods: Sixty-five patients were included. Clinical evaluation and lymphoscintigraphy were performed before and six months after stem cells implantation. The stem cells implantations were carried out by multiple superficial and deep injections in the trajectory of the lymphatic vessels and also in the inguinal region. A volume of 0.75 to 1.00 mL of cell suspension (1.0-2.2 x 109 stem cells) was administered in each injection site. Lymphoscintigraphy: Whole-body scans were acquired at 20 minutes, 1 hour, and 3 hours after administration of 185 to 259 MBq (5–7mCi) of 99m Tc-albumin nanocolloids in the interdigital space of both limbs. The anatomy and function of the lymphatic system were evaluated. Results: Functional assessment before implantation of stem cells showed that 69.2% of the patients had severe lymphatic insufficiency. The 61.5% of patients showed clinical improvement, confirmed by the results of the lymphoscintigraphy. The 46.1% of the cases evaluated showed a clear improvement. The study showed that the isotopic lymphography can evaluate the therapeutic response and its intensity. Conclusion: Lymphoscintigraphy is a useful technique for the evaluation and monitoring of autologous stem cell transplantation in patients with chronic lymphedema. (author)

  20. Autologous orbicularis muscle for filling facial folds-an experimental and clinical study.

    Science.gov (United States)

    Schellini, Silvana Artioli; Hirai, Flavio Eduardo; Hoyama, Erika; Mattos, Maila Karina; Chaves, Fernando Rodrigo; Pellizon, Claudia Helena; Padovani, Carlos Roberto

    2009-01-01

    To present a technique for filling facial folds by using autologous orbicularis oculi muscle, based on an experimental model. two studies are presented: (1) an experimental study using 15 albino guinea-pigs from which a strip of the sural triceps muscle was removed and implanted in the subcutaneous tissue of the dorsal area. The animals were sacrificed 7, 30 and 60 days after the implantation, and the material was histologically evaluated. And (2) an interventional prospective clinical trial carried out on 20 patients referred to blepharoplasty surgery. They received autologous preseptal orbicularis muscle for filling facial folds. The results where evaluated by patients satisfaction and clinical exam. the sural tricep muscle, when implanted in the subcutaneous tissue, resulted in fibrosis. The patients whom received autologous orbicularis muscle implanted for filling facial folds showed that the procedure can be successfully carried out. autologous preseptal orbicularis muscle is a good material for filling facial folds. Cicatricial tissue will be formed on its implantation site, filling the tissue gap that forms the folds on the skin.

  1. Clinical Allogeneic and Autologous Islet Cell Transplantation: Update

    Directory of Open Access Journals (Sweden)

    Shinichi Matsumoto

    2011-06-01

    Full Text Available Islet cell transplantation is categorized as a β-cell replacement therapy for diabetic patients who lack the ability to secrete insulin. Allogeneic islet cell transplantation is for the treatment of type 1 diabetes, and autologous islet cell transplantation is for the prevention of surgical diabetes after a total pancreatectomy. The issues of allogeneic islet cell transplantation include poor efficacy of islet isolation, the need for multiple donor pancreata, difficulty maintaining insulin independence and undesirable side effects of immunosuppressive drugs. Those issues have been solved step by step and allogeneic islet cell transplantation is almost ready to be the standard therapy. The donor shortage will be the next issue and marginal and/or living donor islet cell transplantation might alleviate the issue. Xeno-islet cell transplantation, β-cell regeneration from human stem cells and gene induction of the naïve pancreas represent the next generation of β-cell replacement therapy. Autologous islet cell transplantation after total pancreatectomy for the treatment of chronic pancreatitis with severe abdominal pain is the standard therapy, even though only limited centers are able to perform this treatment. Remote center autologous islet cell transplantation is an attractive option for hospitals performing total pancreatectomies without the proper islet isolation facilities.

  2. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [ARIES Collaborative, New York, NY (United States); Podorson, David [ARIES Collaborative, New York, NY (United States); Varshney, Kapil [ARIES Collaborative, New York, NY (United States)

    2014-05-01

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

  3. Development of mini-LIA and primary experiments

    International Nuclear Information System (INIS)

    Cheng Cheng; Liao Shuqing; Zheng Shuxin; Lin Yuzheng; Tang Chuanxiang; Jing Xiaobing; Mu Fan; Pan Haifeng; Zhang Kaizhi; Shi Jinshui; Deng Jianjun

    2009-01-01

    Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)

  4. Mini lathe machine converted to CNC

    Directory of Open Access Journals (Sweden)

    Alexandru Morar

    2012-06-01

    Full Text Available This paper presents the adaptation of a mechanical mini-lathing machine to a computerized numerical control (CNC lathing machine. This machine is composed of a ASIST mini-lathe and a two-degrees-of-freedom XZ stage designed specifically for this application. The whole system is controlled from a PC using adequate CNC control software.

  5. Backward can extrusion with conical,rotating punch as a cold forging tribology test

    DEFF Research Database (Denmark)

    Ceron, Ermanno; Bay, Niels; Tetsuo, A.

    2011-01-01

    with an analysis of the sliding velocity distribution along the punch nose. The latter is determined by FE analysis of the test. Results show friction stress for unalloyed low C-steel provided with different types of lubricants, e.g. phosphate coating plus soap, phosphate coating plus MoS2 and single bathe...... lubrication with PULS. The new test is so severe, that it is possible to break down the best lubrication systems for cold forging, such as phosphate coating plus soap and MoS2....

  6. Preeclampsia in autologous and oocyte donation pregnancy: is there a different pathophysiology?

    Science.gov (United States)

    Lashley, Lisa E E L O; Buurma, Aletta; Swings, Godelieve M J S; Eikmans, Michael; Anholts, Jacqueline D H; Bakker, Jaap A; Claas, Frans H J

    2015-06-01

    Oocyte donation (OD) is a specific method of artificial reproductive technology that is accompanied by a higher risk of preeclampsia during pregnancy. The pathophysiological mechanism underlying preeclampsia in OD pregnancies is thought to differ from preeclampsia in autologous pregnancies. As preeclampsia in autologous pregnancies is suggested to be associated with complement activation, we studied C4d deposition, circulating complement components and placental complement regulatory proteins in preeclamptic OD pregnancies. Women with uncomplicated and preeclamptic pregnancies after OD or spontaneous conception were selected. We stained the placentas for C4d, marker for complement activation, measured complement factors C1q, C3 and C4 in maternal sera and quantified the placental mRNA expression of complement regulatory proteins CD46, CD55 and CD59. A significantly (p preeclampsia compared with uncomplicated pregnancies, both OD and autologous. The level of complement factors in serum did not differ between the groups. Children born in the autologous preeclampsia group were significantly lower in birth weight (p preeclampsia pregnancies, there is excessive activation of complement in preeclamptic OD pregnancies. However, in contrast to autologous pregnancies this is not associated with counterbalancing upregulation of complement regulatory proteins. Furthermore, C4d deposition in OD pregnancies is not related to the severity of preeclampsia, suggesting another trigger or regulatory mechanism of placental C4d deposition in preeclamptic OD pregnancies. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Detection of dementia in primary care: comparison of the original and a modified Mini-Cog Assessment with the Mini-Mental State Examination.

    Science.gov (United States)

    Kamenski, Gustav; Dorner, Thomas; Lawrence, Kitty; Psota, Georg; Rieder, Anita; Schwarz, Franz; Sepandj, Asita; Spiegel, Wolfgang; Strotzka, Stefan

    2009-12-01

    Background Dementia is considered widely under-detected in primary care, and general practitioners (GPs) frequently ask for easy to use tools to assist in its early detection.Aim To determine the degree of correlation between the Mini-Cog Assessment (Mini-Cog) as performed by GPs and the Mini-Mental State Examination (MMSE).Design of study This was a prospective study (2005, 2006) comparing two cognitive screening instruments.Setting Ten general practices in Austria, with patients with a hitherto undiagnosed suspicion of dementia seen consecutively.Method Sensitivity, specificity and positive and negative predictive values (PPVs and NPVs) of the Mini-Cog (applying both a colour-coded and the original rating method) were assessed for degree of correlation with the MMSE. In phase one GPs examined patients suspected of having dementia using the Mini-Cog; in phase two a neurologist retested them applying the MMSE, a clock-drawing test (CDT) and a routine clinical examination. A questionnaire on the practicability of the Mini-Cog was answered by GPs.Results Of the 107 patients who participated 86 completed the whole study protocol. The Mini-Cog, as performed by the ten GPs, displayed a sensitivity of 0.85 (95% CI: 0.71, 0.98), a specificity of 0.58 (95% CI: 0.46, 0.71), a PPV of 0.47 (95% CI: 0.33, 0.61) and an NPV of 0.90 (95% CI: 0.80, 0.99) as against the MMSE carried out by neurologists. The GPs judged the Mini-Cog useful and time saving.Conclusion The Mini-Cog has a high sensitivity and acceptable specificity in the general practice setting and has proved to be a practicable tool for the diagnosis of dementia in primary care.

  8. Management of vocal fold scar with autologous fat implantation: perceptual results.

    Science.gov (United States)

    Neuenschwander, M C; Sataloff, R T; Abaza, M M; Hawkshaw, M J; Reiter, D; Spiegel, J R

    2001-06-01

    Vocal fold scar disrupts the mucosal wave and interferes with glottic closure. Treatment involves a multidisciplinary approach that includes voice therapy, medical management, and sometimes surgery. We reviewed the records of the first eight patients who underwent autologous fat implantation for vocal fold scar. Information on the etiology of scar, physical findings, and prior interventions were collected. Videotapes of videostroboscopic findings and perceptual voice ratings [Grade, Roughness, Breathiness, Asthenia, Strain (GRBAS)] were randomized and analyzed independently by four blinded observers. Etiology of scar included mass excision (7), vocal fold stripping (3), congenital sulcus (2), and hemorrhage (1). Prior surgical procedures performed included thyroplasty (1), autologous fat injection (9), excision of scar (2), and lysis of adhesions (2). Strobovideolaryngoscopy: Statistically significant improvement was found in glottic closure, mucosal wave, and stiffness (P = 0.05). Perceptual ratings (GRBAS): Statistically significant improvement was found in all five parameters, including overall Grade, Roughness, Breathiness, Asthenia, and Strain (P = 0.05). Patients appear to have improved vocal fold function and quality of voice after autologous fat implantation in the vocal fold. Autologous fat implantation is an important adjunctive procedure in the management of vocal fold scar, and a useful addition to the armamentarium of the experienced phonomicrosurgeon.

  9. Prospects for Antineutrino Running at MiniBooNE

    OpenAIRE

    Wascko, M. O.

    2006-01-01

    MiniBooNE began running in antineutrino mode on 19 January, 2006. We describe the sensitivity of MiniBooNE to LSND-like nuebar oscillations and outline a program of antineutrino cross-section measurements necessary for the next generation of neutrino oscillation experiments. We describe three independent methods of constraining wrong-sign (neutrino) backgrounds in an antineutrino beam, and their application to the MiniBooNE antineutrino analyses.

  10. Autologous bone marrow mononuclear cell delivery to dilated ...

    African Journals Online (AJOL)

    Autologous bone marrow mononuclear cell delivery to dilated cardiomyopathy patients: A clinical trial. PLN Kaparthi, G Namita, LK Chelluri, VSP Rao, PK Shah, A Vasantha, SK Ratnakar, K Ravindhranath ...

  11. Efficacy of Punch Elevation Combined with Fractional Carbon Dioxide Laser Resurfacing in Facial Atrophic Acne Scarring: A Randomized Split-face Clinical Study

    Science.gov (United States)

    Faghihi, Gita; Nouraei, Saeid; Asilian, Ali; Keyvan, Shima; Abtahi-Naeini, Bahareh; Rakhshanpour, Mehrdad; Nilforoushzadeh, Mohammad Ali; Hosseini, Sayed Mohsen

    2015-01-01

    Background: A number of treatments for reducing the appearance of acne scars are available, but general guidelines for optimizing acne scar treatment do not exist. The aim of this study was to compare the clinical effectiveness and side effects of fractional carbon dioxide (CO2) laser resurfacing combined with punch elevation with fractional CO2 laser resurfacing alone in the treatment of atrophic acne scars. Materials and Methods: Forty-two Iranian subjects (age range 18–55) with Fitzpatrick skin types III to IV and moderate to severe atrophic acne scars on both cheeks received randomized split-face treatments: One side received fractional CO2 laser treatment and the other received one session of punch elevation combined with two sessions of laser fractional CO2 laser treatment, separated by an interval of 1 month. Two dermatologists independently evaluated improvement in acne scars 4 and 16 weeks after the last treatment. Side effects were also recorded after each treatment. Results: The mean ± SD age of patients was 23.4 ± 2.6 years. Clinical improvement of facial acne scarring was assessed by two dermatologists blinded to treatment conditions. No significant difference in evaluation was observed 1 month after treatment (P = 0.56). Their evaluation found that fractional CO2 laser treatment combined with punch elevation had greater efficacy than that with fractional CO2 laser treatment alone, assessed 4 months after treatment (P = 0.02). Among all side effects, coagulated crust formation and pruritus at day 3 after fractional CO2 laser treatment was significant on both treatment sides (P < 0.05). Conclusion: Concurrent use of fractional laser skin resurfacing with punch elevation offers a safe and effective approach for the treatment of acne scarring. PMID:26538695

  12. Efficacy of punch elevation combined with fractional carbon dioxide laser resurfacing in facial atrophic acne scarring: A randomized split-face clinical study

    Directory of Open Access Journals (Sweden)

    Gita Faghihi

    2015-01-01

    Full Text Available Background: A number of treatments for reducing the appearance of acne scars are available, but general guidelines for optimizing acne scar treatment do not exist. The aim of this study was to compare the clinical effectiveness and side effects of fractional carbon dioxide (CO 2 laser resurfacing combined with punch elevation with fractional CO 2 laser resurfacing alone in the treatment of atrophic acne scars. Materials and Methods: Forty-two Iranian subjects (age range 18-55 with Fitzpatrick skin types III to IV and moderate to severe atrophic acne scars on both cheeks received randomized split-face treatments: One side received fractional CO 2 laser treatment and the other received one session of punch elevation combined with two sessions of laser fractional CO 2 laser treatment, separated by an interval of 1 month. Two dermatologists independently evaluated improvement in acne scars 4 and 16 weeks after the last treatment. Side effects were also recorded after each treatment. Results: The mean ± SD age of patients was 23.4 ± 2.6 years. Clinical improvement of facial acne scarring was assessed by two dermatologists blinded to treatment conditions. No significant difference in evaluation was observed 1 month after treatment (P = 0.56. Their evaluation found that fractional CO 2 laser treatment combined with punch elevation had greater efficacy than that with fractional CO 2 laser treatment alone, assessed 4 months after treatment (P = 0.02. Among all side effects, coagulated crust formation and pruritus at day 3 after fractional CO 2 laser treatment was significant on both treatment sides (P < 0.05. Conclusion: Concurrent use of fractional laser skin resurfacing with punch elevation offers a safe and effective approach for the treatment of acne scarring.

  13. A mini-UAV VTOL Platform for Surveying Applications

    Directory of Open Access Journals (Sweden)

    Kuldeep Rawat

    2014-05-01

    Full Text Available In this paper we discuss implementation of a mini-Unmanned Aerial Vehicle (UAV vertical take-off and landing (VTOL platform for surveying activities related to highway construction. Recent advances in sensor and communication technologies have allowed scaling sizes of unmanned aerial platforms, and explore them for tasks that are economical and safe over populated or inhabited areas. In highway construction the capability of mini-UAVs to survey in hostile and/or hardly accessible areas can greatly reduce human risks. The project focused on developing a cost effective, remotely controlled, fuel powered mini-UAV VTOL (helicopter platform with certain payload capacity and configuration and demonstrated its use in surveying and monitoring activities required for highway planning and construction. With an on-board flight recorder global positioning system (GPS device, memory storage card, telemetry, inertial navigation sensors, and a video camera the mini-UAV can record flying coordinates and relay live video images to a remote ground receiver and surveyor. After all necessary integration and flight tests were done the mini-UAV helicopter was tested to operate and relay video from the areas where construction was underway. The mini-UAV can provide a platform for a range of sensors and instruments that directly support the operational requirements of transportation sector.

  14. Performance improvement in a tubular heat exchanger by punched delta-winglet vortex generators

    Science.gov (United States)

    Khanoknaiyakarn, C.; Promvonge, P.; Thianpong, C.; Skullong, S.

    2018-01-01

    A novel tubular heat exchanger incorporated with punched delta-winglet vortex generators (called perforated delta-winglet vortex generator, P-DWVG) is proposed for improving its thermal performance and energy saving. The P-DWVG elements are punched out from a straight tape having its width nearly equal to the tube diameter before insertion. The main aim at employing the P-DWVG insert is to produce counter-rotating vortices along the tube to promote turbulence intensity inside as well as to transport the cold fluid at the central core to the near-wall regions. The experiment was performed to study thermal behaviors in a uniform heat-fluxed tube inserted with P-DWVGs. The P-DWVGs with the attack angle of 45° were mounted periodically with three different blockage ratios (BR = 0.1, 0.2 and 0.3) and two pitch ratios (PR = 2 and 3). Air as the test fluid was varied to obtain turbulent airflow for Reynolds number (Re) in a range of 4,150-25,500. The experimental results show that the P-DWVG provides a considerable increase in the rate of heat transfer around 3.1-4.01 times whereas friction factor increases around 11.44- 34.23 times higher than the plain tube. To assess the real benefits of P-DWVGs, thermal performance factor (TEF) is examined and in the range of 1.39-1.48 where its maximum is at BR = 0.1 and PR = 2.

  15. Designing a mini subcritical nuclear reactor; Diseno de un mini reactor nuclear subcritico

    Energy Technology Data Exchange (ETDEWEB)

    Escobedo G, C. R.; Vega C, H. R.; Davila H, V. M., E-mail: rafelaescobedo@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Jardin Juarez 147, Col. Centro, 98000 Zacatecas, Zac. (Mexico)

    2015-10-15

    In this work the design of a mini subcritical nuclear reactor formed by means of light water moderator, uranium as fuel, and isotopic neutron source of {sup 239}PuBe was carried out. The design was done by Monte Carlo methods with the code MCNP5 in which uranium was modeled in an array of concentric holes cylinders of 8.5, 14.5, 20.5, 26.5, 32.5 cm of internal radius and 3 cm of thickness, 36 cm of height. Different models were made from a single fuel cylinder (natural uranium) to five. The neutron source of {sup 239}PuBe was situated in the center of the mini reactor; in each arrangement was used water as moderator. Cross sections libraries Endf/Vi were used and the number of stories was large enough to ensure less uncertainty than 3%. For each case the effective multiplication factor k{sub e}-f{sub f}, the amplification factor and the power was calculated. Outside the mini reactor the ambient dose equivalent H (10) was calculated for different cases. The value of k{sub eff}, the amplification factor and power are directly related to the number of cylinders of uranium as fuel. Although the average energy of the neutrons {sup 239}PuBe is between 4.5 and 5 MeV in the case of the mini reactor for a cylinder, in the neutron spectrum the presence of thermal neutrons does not exist, so that produced fissions are generated with fast neutrons, and in designs of two and three rings the neutron spectra shows the presence of thermal neutrons, however the fissions are being generated with fast neutrons. Finally in the four and five cases the amount of moderator is enough to thermalized the neutrons and thereby produce the fission. The maximum value for k{sub eff} was 0.82; this value is very close to the assembly of Universidad Autonoma de Zacatecas generating a k{sub eff} of 0.86. According to the safety and radiation protection standards for the design of mini reactor of one, two and three cylinders they comply with the established safety, while designs of four and five

  16. [The "Mini-ICF-Rating for Mental Disorders (Mini-ICF-P)". A short instrument for the assessment of disabilities in mental disorders].

    Science.gov (United States)

    Linden, M; Baron, S

    2005-06-01

    Supplementary to the description of diseases at symptom level, the International Classification of Functioning, Disability and Health (ICF), edited by the WHO, for the first time enables a systematic description also at the level of disabilities and impairments. The Mini-ICF-Rating for Mental Disorders (Mini-ICF-P) is a short observer rating instrument for the assessment of disabilities, especially with regard to occupational functioning. The Mini-ICF-P was first evaluated empirically in 125 patients of a Department of Behavioural Medicine and Psychosomatics. Parallel-test reliability was r = 0.59. Correlates were found with cognitive and motivational variables and duration of sick leave from work. In summary, the Mini-ICF-P is a quick and practicable instrument.

  17. Mini International Neuropsychiatric Interview (MINI: validação de entrevista breve para diagnóstico de transtornos mentais

    Directory of Open Access Journals (Sweden)

    Amorim Patrícia

    2000-01-01

    Full Text Available Objetivos: O MINI é uma entrevista diagnóstica padronizada breve (15-30 minutos, compatível com os critérios do DSM-III-R/IV e da CID-10, que é destinada à utilização na prática clínica e na pesquisa em atenção primária e em psiquiatria, e pode ser utilizada por clínicos após um treinamento rápido (de 1 a 3 horas. A versão Plus do MINI, mais detalhada, gera diagnósticos positivos dos principais transtornos psicóticos e do humor do DSM-IV. Este artigo apresenta os resultados de quatro estudos de validação do instrumento, realizados na Europa e nos EUA. Métodos: Os estudos 1 (França e 2 (EUA testaram a confiabilidade -entre avaliadores e teste-reteste -da versão DSM-III-R do MINI (n=84, sendo 42 pacientes psiquiátricos de cada centro e sua validade com relação ao CIDI (n=346, sendo 296 pacientes psiquiátricos e 50 controles e ao SCID-P (n=370, sendo 308 pacientes psiquiátricos e 62 controles, respectivamente. O estudo 3 testou a validade de diagnósticos gerados por clínicos gerais usando o MINI (DSM-IV com relação aos diagnósticos clínicos habituais de psiquiatras, em 409 pacientes de centros de atenção primária de quatro países (França, Espanha, Itália e Reino Unido. O estudo 4 testou a confiabilidade entre avaliadores (n=20 pacientes psiquiátricos e a validade dos módulos Transtornos Psicóticos, Depressão e Mania do MINI Plus - DSM IV (n=104 pacientes psiquiátricos com relação a dois critérios de referência: diagnósticos do CIDI e diagnósticos clínicos de psiquiatras. Análises quantitativas (índices de concordância e de validade e qualitativas (razões de discordância foram realizadas. Resultados: Os índices de confiabilidade do MINI (estudos 1 e 2 e do MINI Plus (estudo 4 foram globalmente satisfatórios. Comparados a vários critérios de referência (CIDI, SCID-P, opinião de peritos, em diferentes contextos (unidades psiquiátricas e centros de atenção primária, o MINI e o MINI

  18. PV-hybrid and mini-grid

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Within the 5th European PV-hybrid and mini-grid conference 29th and 30th April, 2010 in Tarragona (Spain) the following lectures were held: (1) Overview of IEA PVPS Task 11 PV-hybrid systems within mini grids; (2) Photovoltaic revolution for deployment in developing countries; (3) Legal and financial conditions for the sustainable operation of mini-grids; (4) EU instruments to promote renewable energies in developing countries; (5) PV hybridization of diesel electricity generators: Conditions of profitability and examples in differential power and storage size ranges; (6) Education suit of designing PV hybrid systems; (7) Sustainable renewable energy projects for intelligent rural electrification in Laos, Cambodia and Vietnam; (8) Techno-economic feasibility of energy supply of remote villages in Palestine by PV systems, diesel generators and electric grid (Case studies: Emnazeil and Atouf villages); (9) Technical, economical and sustainability considerations of a solar PV mini grid as a tool for rural electrification in Uganda; (10) Can we rate inverters for rural electrification on the basis of energy efficiency?; (11) Test procedures for MPPT charge controllers characterization; (12) Energy storage for mini-grid stabilization; (13) Redox flow batteries - Already an alternative storage solution for hybrid PV mini-grids?; (14) Control methods for PV hybrid mini-grids; (15) Partial AC-coupling in mini-grids; (15) Normative issues of small wind turbines in PV hybrid systems; (16) Communication solutions for PV hybrid systems; (17) Towards flexible control and communication of mini-grids; (18) PV/methanol fuel cell hybrid system for powering a highway security variable message board; (19) Polygeneration smartgrids: A solution for the supply of electricity, potable water and hydrogen as fuel for transportation in remote Areas; (20) Implementation of the Bronsbergen micro grid using FACDS; (21) A revisited approach for the design of PV wind hybrid systems; (22

  19. Tooling solutions for sheet metal forming and punching of lean duplex stainless steel

    DEFF Research Database (Denmark)

    Wadman, Boel; Madsen, Erik; Bay, Niels

    2012-01-01

    .4509 and lean duplex EN1.4162 in a production designed for austenitic stainless steels, such as EN1.4301 and 1.4401. The result is a guideline that summarizes how stainless material properties may affect tool degradation, and suggests tool solutions for reduced production disturbances and tool maintenance cost.......For producers of advanced stainless components the choice of stainless material influences not only the product properties, but also the tooling solution for sheet metal stamping. This work describes how forming and punching tools will be affected when introducing the stainless alloys ferritic EN1...

  20. The small punch assessment of toughness losses in low alloy steels

    Energy Technology Data Exchange (ETDEWEB)

    Bulloch, J H [ESB, Power Generation, Dublin (Ireland)

    1999-12-31

    The presentation deals at length with the relationship between the Small Punch, SP, test transition temperature Tsp, behaviour and those displayed by the conventional Charpy Fracture Appearance Transition Temperature, FATT, obtained from large test specimens. Essentially it was demonstrated that the total test temperature range trends could reasonably be described by a non-linear expression such as FATT varied inversely with the square of the Tsp. Finally when the Tsp against FATT trends were separated into different steel classes an encouraging picture emerged inasmuch that a reasonable amount of data exhibited good agreement with the predicted effects of grain size. Fractographic details were also discussed and strong effects of strain or loading rates were identified. (orig.) 19 refs.

  1. The small punch assessment of toughness losses in low alloy steels

    Energy Technology Data Exchange (ETDEWEB)

    Bulloch, J.H. [ESB, Power Generation, Dublin (Ireland)

    1998-12-31

    The presentation deals at length with the relationship between the Small Punch, SP, test transition temperature Tsp, behaviour and those displayed by the conventional Charpy Fracture Appearance Transition Temperature, FATT, obtained from large test specimens. Essentially it was demonstrated that the total test temperature range trends could reasonably be described by a non-linear expression such as FATT varied inversely with the square of the Tsp. Finally when the Tsp against FATT trends were separated into different steel classes an encouraging picture emerged inasmuch that a reasonable amount of data exhibited good agreement with the predicted effects of grain size. Fractographic details were also discussed and strong effects of strain or loading rates were identified. (orig.) 19 refs.

  2. The Mini-Cog, Clock Drawing Test, and the Mini-Mental State Examination in a German memory clinic: specificity of separation dementia from depression.

    Science.gov (United States)

    Milian, Monika; Leiherr, Anna-Maria; Straten, Guido; Müller, Stephan; Leyhe, Thomas; Eschweiler, Gerhard W

    2013-01-01

    The aim of this study was to assess the specificities of the Mini-Cog, the Clock Drawing Test (CDT), and the Mini-Mental State Examination (MMSE) against depression and healthy controls in a German Memory Clinic. Furthermore, we analyzed the specificities of all three screening instruments in dependence of actual depression severity. Data from 142 depressed elderly, 438 dementia patients, and 64 healthy controls were retrospectively analyzed. The CDT and an extraction of the three-item recall of the MMSE were used to constitute the Mini-Cog algorithm. Depression severity was rated by either the Beck Depression Inventory (BDI) or the Geriatric Depression Scale (GDS) depending on the age of the patients. The Mini-Cog achieved a specificity of 79.6% against depressed elderly and 100.0% against healthy subjects (p Mini-Cog and the CDT, but also showed the lowest sensitivity for the detection of dementia. Surprisingly, the depression severity had no effect on the specificity of the Mini-Cog and the CDT, only the MMSE was susceptible for the depression severity. Although the MMSE showed higher specificities, the weighting between the sensitivities and specificities in all tests prove again the Mini-Cog as a short, valid, and sensitive screening tool.

  3. Efficacy of autologous platelets in macular hole surgery

    Directory of Open Access Journals (Sweden)

    Konstantinidis A

    2013-04-01

    Full Text Available Aristeidis Konstantinidis,1,2 Mark Hero,2 Panagiotis Nanos,1 Georgios D Panos1,3 1Department of Ophthalmology, University Hospital of Alexandroupolis, Alexandroupolis, Greece; 2Opthalmology Department, University Hospital Coventry and Warwickshire, Coventry, UK; 3Department of Ophthalmology, University Hospitals of Geneva, Geneva, Switzerland Abstract: The introduction of optical coherence tomography has allowed accurate measurement of the size of macular holes. A retrospective consecutive review was performed of 21 patients undergoing macular hole repair with vitrectomy, gas tamponade, and autologous platelet injection and we assessed the effect of macular hole parameters on anatomic and functional outcomes. We looked at the demographic features, final visual outcome, and anatomical closure. Twenty-one patients were included in the study. They underwent routine vitrectomy with gas tamponade (C3F8 and injection of autologous platelets. All patients were advised to maintain a facedown posture for 2 weeks. Anatomical closure was confirmed in all cases and 20 out of 21 of patients had improved postoperative visual acuity by two or more lines. In our series, the macular hole dimensions did not have much effect on the final results. The use of autologous platelets and strict facedown posture seems to be the deciding factor in good anatomical and visual outcome irrespective of macular hole dimensions. Keywords: macular hole, platelets, vitrectomy

  4. The model of pulmonary embolism caused by autologous thrombus in rabbits

    OpenAIRE

    Yu-Jiao Ding; Yang Chen

    2017-01-01

    Objective: To establish a model of pulmonary embolism in rabbits by using autologous thrombosis of rabbit ear vein, to study the method of establishing acute pulmonary embolism by using autologous thrombus and to explore the diagnostic value of oxygen partial pressure in acute pulmonary embolism. Methods: Twenty rabbits were randomly divided into normal group (n=5), 7 h group, 24h group, 1 week after model establishment Group. The arterial blood gas analysis was performed on th...

  5. Quality of harvested autologous platelets compared with stored donor platelets for use after cardiopulmonary bypass procedures.

    Science.gov (United States)

    Crowther, M; Ford, I; Jeffrey, R R; Urbaniak, S J; Greaves, M

    2000-10-01

    Platelet dysfunction has a major contribution in bleeding after cardiopulmonary bypass (CPB) and transfusion of platelets is frequently used to secure haemostasis. Allogeneic platelets prepared for transfusion are functionally impaired. Autologous platelets harvested preoperatively require a shorter storage time before transfusion and their use also avoids the risks associated with transfusion of allogeneic blood products. For the first time, we have compared the functional quality of autologous platelets with allogeneic platelets prepared by two methods, immediately before infusion. Platelet activation was assessed by P-selectin expression and fibrinogen binding using flow cytometry. We also monitored the effects of CPB surgery and re-infusion of autologous platelets on platelet function. Autologous platelet-rich plasma (PRP) contained a significantly lower (P platelets compared with allogeneic platelet preparations, and also contained a significantly higher (P platelets. Allogeneic platelets prepared by donor apheresis were more activated and less responsive than those produced by centrifugation of whole blood. In patients' blood, the percentage of platelets expressing P-selectin or binding fibrinogen increased significantly after CPB (P platelets responsive to in vitro agonists was decreased (P platelet activation during the procedure. The percentage of activated platelets decreased (statistically not significant) after re-infusion of autologous PRP. P-selectin expression had returned to pre-CPB levels 24 h post-operatively. Autologous platelet preparations display minimal activation, but remain responsive. Conservation of platelet function may contribute to the potential clinical benefits of autologous transfusion in cardiopulmonary bypass.

  6. Effect of hyperbaric oxygen therapy combined with autologous platelet concentrate applied in rabbit fibula fraction healing

    Directory of Open Access Journals (Sweden)

    Paulo Cesar Fagundes Neves

    2013-09-01

    Full Text Available OBJECTIVES: The purpose is to study the effects of hyperbaric oxygen therapy and autologous platelet concentrates in healing the fibula bone of rabbits after induced fractures. METHODS: A total of 128 male New Zealand albino rabbits, between 6-8 months old, were subjected to a total osteotomy of the proximal portion of the right fibula. After surgery, the animals were divided into four groups (n = 32 each: control group, in which animals were subjected to osteotomy; autologous platelet concentrate group, in which animals were subjected to osteotomy and autologous platelet concentrate applied at the fracture site; hyperbaric oxygen group, in which animals were subjected to osteotomy and 9 consecutive daily hyperbaric oxygen therapy sessions; and autologous platelet concentrate and hyperbaric oxygen group, in which animals were subjected to osteotomy, autologous platelet concentrate applied at the fracture site, and 9 consecutive daily hyperbaric oxygen therapy sessions. Each group was divided into 4 subgroups according to a pre-determined euthanasia time points: 2, 4, 6, and 8 weeks postoperative. After euthanasia at a specific time point, the fibula containing the osseous callus was prepared histologically and stained with hematoxylin and eosin or picrosirius red. RESULTS: Autologous platelet concentrates and hyperbaric oxygen therapy, applied together or separately, increased the rate of bone healing compared with the control group. CONCLUSION: Hyperbaric oxygen therapy and autologous platelet concentrate combined increased the rate of bone healing in this experimental model.

  7. Latissimus Dorsi and Immediate Fat Transfer (LIFT for Complete Autologous Breast Reconstruction

    Directory of Open Access Journals (Sweden)

    James M. Economides, MD

    2018-01-01

    Conclusion:. Autologous augmentation of the LD flap with lipotransfer has been used to avoid placement of an implant. We improve the technique by performing lipotransfer during index reconstruction. Furthermore, we perform lipotransfer prior to disorigination of the LD muscle to minimize trauma to the flap and increase the efficiency of fat grafting. Our experience demonstrates that this technique is a viable autologous alternative to microsurgical breast reconstruction.

  8. [Autologous fat grafting in children].

    Science.gov (United States)

    Baptista, C; Bertrand, B; Philandrianos, C; Degardin, N; Casanova, D

    2016-10-01

    Lipofilling or fat grafting transfer is defined as a technique of filling soft tissue by autologous fat grafting. The basic principle of lipofilling is based on a harvest of adipose tissue, followed by a reinjection after treatment. Lipofilling main objective is a volume defect filling, but also improving cutaneous trophicity. Lipofilling specificities among children is mainly based on these indications. Complications of autologous fat grafting among children are the same as those in adults: we distinguish short-term complications (intraoperative and perioperative) and the medium and long-term complications. The harvesting of fat tissue is the main limiting factor of the technique, due to low percentage of body fat of children. Indications of lipofilling among children may be specific or similar to those in adults. There are two types of indications: cosmetic, in which the aim of lipofilling is correcting a defect density, acquired (iatrogenic, post-traumatic scar) or malformation (otomandibular dysplasia, craniosynostosis, Parry Romberg syndrom, Poland syndrom, pectus excavatum…). The aim of functional indications is correcting a velar insufficiency or lagophthalmos. In the paediatric sector, lipofilling has become an alternative to the conventional techniques, by its reliability, safety, reproducibility, and good results. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Mastectomy Skin Necrosis After Breast Reconstruction: A Comparative Analysis Between Autologous Reconstruction and Implant-Based Reconstruction.

    Science.gov (United States)

    Sue, Gloria R; Lee, Gordon K

    2018-05-01

    Mastectomy skin necrosis is a significant problem after breast reconstruction. We sought to perform a comparative analysis on this complication between patients undergoing autologous breast reconstruction and patients undergoing 2-stage expander implant breast reconstruction. A retrospective review was performed on consecutive patients undergoing autologous breast reconstruction or 2-stage expander implant breast reconstruction by the senior author from 2006 through 2015. Patient demographic factors including age, body mass index, history of diabetes, history of smoking, and history of radiation to the breast were collected. Our primary outcome measure was mastectomy skin necrosis. Fisher exact test was used for statistical analysis between the 2 patient cohorts. The treatment patterns of mastectomy skin necrosis were then analyzed. We identified 204 patients who underwent autologous breast reconstruction and 293 patients who underwent 2-stage expander implant breast reconstruction. Patients undergoing autologous breast reconstruction were older, heavier, more likely to have diabetes, and more likely to have had prior radiation to the breast compared with patients undergoing implant-based reconstruction. The incidence of mastectomy skin necrosis was 30.4% of patients in the autologous group compared with only 10.6% of patients in the tissue expander group (P care in the autologous group, only 3.2% were treated with local wound care in the tissue expander group (P skin necrosis is significantly more likely to occur after autologous breast reconstruction compared with 2-stage expander implant-based breast reconstruction. Patients with autologous reconstructions are more readily treated with local wound care compared with patients with tissue expanders, who tended to require operative treatment of this complication. Patients considering breast reconstruction should be counseled appropriately regarding the differences in incidence and management of mastectomy skin

  10. Reduced use of allogeneic platelets through high-yield perioperative autologous plateletpheresis and reinfusion.

    Science.gov (United States)

    Alberts, Melissa; Bandarenko, Nicholas; Gaca, Jeffrey; Lockhart, Evelyn; Milano, Carmelo; Alexander, Stanlin; Linder, Dean; Lombard, Frederick W; Welsby, Ian J

    2014-05-01

    Intraoperative autologous platelet (PLT) collection as part of a multimodal blood conservation program carries a Class IIa recommendation from the Societies of Thoracic Surgeons and Cardiovascular Anesthesiologists, but achieving a suitable PLT yield limits its application. A novel, autologous, intraoperative, high-yield plateletpheresis collection program was established and retrospectively analyzed to identify potential improvements over previously reported plateletpheresis protocols. Targeting complex cardiothoracic surgery patients without recent anti-PLT agents, thrombocytopenia, or severe anemia, the program aimed to achieve a PLT yield of at least one standard apheresis unit (3.0 × 10(11) ) within 60 to 90 minutes and using an automated plateletpheresis device (Trima, Terumo BCT). Anesthetized and invasively monitored patients underwent plateletpheresis via a large-bore, indwelling central line placed for the surgery. Collection-related data for quality control purposes and subsequent PLT transfusion requirements were analyzed and reported. Forty-two patients donated autologous PLTs between 2011 and 2012. PLT yield was 4.5 (3.9-5.0) × 10(11) , which significantly exceeds previously reported yields, and procedure duration was 53.2 (48.4-57.9) minutes. As anticipated, postcollection PLT count decreased from 268 (242-293) × 10(9) to 182 (163-201) × 10(9) /L; hypocalcemia was minimized by infusion of 1 g of CaCl2 . Autologous PLT yield was inversely correlated with allogeneic PLT use, and avoidance of allogeneic PLT transfusion was increased when the autologous yield was the equivalent of 2 or more apheresis units. High-yield, intraoperative autologous PLT collection is achievable using an automated plateletpheresis device. Initial experience shows a reduction in reliance on allogeneic PLTs for complex cardiothoracic surgery. © 2013 American Association of Blood Banks.

  11. Automated intelligent rotor tine cultivation and punch planting to improve the selectivity of mechanical intra-row weed control

    DEFF Research Database (Denmark)

    Rasmussen, Jesper; Griepentrog, Hans W.; Nielsen, Jon

    2012-01-01

    in sugar beet and carrot crops showed no synergistic effects between plant establishment procedures and selectivity of post-emergence weed harrowing. Even if punch planting and automated intelligent rotor tine cultivation were not combined, the results indicated that there was no reason to believe...... that mainly work through soil burial....

  12. Autologous Adipose-Derived Tissue Matrix Part I: Biologic Characteristics.

    Science.gov (United States)

    Schendel, Stephen A

    2017-10-01

    Autologous collagen is an ideal soft tissue filler and may serve as a matrix for stem cell implantation and growth. Procurement of autologous collagen has been limited, though, secondary to a sufficient source. Liposuction is a widely performed and could be a source of autologous collagen. The amount of collagen and its composition in liposuctioned fat remains unknown. The purpose of this research was to characterize an adipose-derived tissue-based product created using ultrasonic cavitation and cryo-grinding. This study evaluated the cellular and protein composition of the final product. Fat was obtained from individuals undergoing routine liposuction and was processed by a 2 step process to obtain only the connective tissue. The tissue was then evaluated by scanning electronic microscope, Western blot analysis, and flow cytometry. Liposuctioned fat was obtained from 10 individuals with an average of 298 mL per subject. After processing an average of 1 mL of collagen matrix was obtained from each 100 mL of fat. Significant viable cell markers were present in descending order for adipocytes > CD90+ > CD105+ > CD45+ > CD19+ > CD144+ > CD34+. Western blot analysis showed collagen type II, III, IV, and other proteins. Scanning electronic microscope study showed a regular pattern of cross-linked, helical collagen. Additionally, vital staing demonstrated that the cells were still viable after processing. Collagen and cells can be easily obtained from liposuctioned fat by ultrasonic separation without alteration of the overall cellular composition of the tissue. Implantation results in new collagen and cellular growth. Collagen matrix with viable cells for autologous use can be obtained from liposuctioned fat and may provide long term results. 5. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  13. Validation and cultural adaptation of the Arabic versions of the Mini-Mental Status Examination - 2 and Mini-Cog test.

    Science.gov (United States)

    Albanna, Mohammad; Yehya, Arij; Khairi, Abdalla; Dafeeah, Elnour; Elhadi, Abdelsalam; Rezgui, Lamia; Al Kahlout, Shahada; Yousif, Adil; Uthman, Basim; Al-Amin, Hassen

    2017-01-01

    The elderly population is increasing around the world, and the prevalence of dementia increases with age. Hence, it is expected that the number of people with dementia will increase significantly in the coming years. The Mini-Mental Status Examination - 2 (MMSE-2) and Mini-Cog are widely used tests to screen for dementia. These scales have good reliability and validity and are easy to administer in clinical and research settings. The purpose of this study was to validate the Arabic versions of MMSE-2 and Mini-Cog. These scales were assessed against the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision ( DSM-IV-TR ) criteria for dementia, as the gold standard. The standard versions of the MMSE-2 and Mini-Cog were translated to Arabic following the back-translation method. Then, a trained rater administered these tests to 134 Arab elderly aged >60 years. A physician, blind to the results of these two tests, assessed the participants for vascular dementia or probable Alzheimer's disease, based on the DSM-IV-TR criteria. The sample included 67.2% Qataris. The mean age was 74.86 years (standard deviation =7.71), and 61.9% did not attend school. The mean of the adjusted scores of MMSE-2 based on age and education level was 19.60 (standard deviation =6.58). According to DSM-IV-TR , 17.2% of the participants had dementia. Sensitivity and specificity of the MMSE-2 and the Mini-Cog together were 71.4% and 61.6%, respectively, which were better than those of each test alone. Together, the Arabic versions of MMSE-2 and Mini-Cog are good screening tools for cognitive impairment in Arabs.

  14. Moving Griffith crack in an orthotropic strip with punches at boundary faces

    Directory of Open Access Journals (Sweden)

    S. Mukherjee

    2005-01-01

    Full Text Available Integral transform technique is employed to solve the elastodynamic problem of steady-state propagation of a Griffith crack centrally situated along the midplane of orthotropic strip of finite thickness 2h and subjected to point loading with centrally situated moving punches under constant pressure along the boundaries of the layer. The problem is reduced to the solution of a pair of simultaneous singular integral equations with Cauchy-type singularities which have finally been solved through the finite Hilbert transform technique. For large h, analytical expression for the stress intensity factor at the crack tip is obtained. Graphical plots of the numerical results are also presented.

  15. Long-term use and follow-up of autologous and homologous cartilage graft in rhinoplasty

    Directory of Open Access Journals (Sweden)

    Ghasemali Khorasani

    2016-05-01

    Full Text Available Background: Cartilage grafting is used in rhinoplasty and reconstructive surgeries. Autologous rib and nasal septum cartilage (auto graft is the preferred source of graft material in rhinoplasty, however, homologous cartilage (allograft has been extensively used to correct the nasal framework in nasal deformities. Autologous cartilage graft usage is restricted with complication of operation and limiting availability of tissue for extensive deformities. Alternatively, preserved costal cartilage allograft represents a readily available and easily contoured material. The current study was a formal systematic review of complications associated with autologous versus homologous cartilage grafting in rhinoplasty patients. Methods: In this cohort retrospective study, a total of 124 patients undergone primary or revision rhinoplasty using homologous or autologus grafts with postoperative follow-up ranging from 6 to 60 months were studied. The types of grafts and complications related to the grafts were evaluated. This included evaluation for warping, infection, resorption, mobility and fracture. Results: The total complications related to the cartilage grafts were 7 cases, which included 1 warped in auto graft group, three cases of graft displacement (two in allograft group and one in auto graft group and three fractures in allograft group. No infection and resorption was recorded. Complication rate (confidence interval 0.95 in autologous and homologous group were 1.25(0.4-3.88 and 2.08(0.78-5.55 in 1000 months follow up. There was no statistically significant difference between autologous and homologous group complications. Onset of complication in autologous and homologous group were 51.23(49.27-53.19 and 58.7(54.51-62.91 month respectively (P=0.81. Conclusion: The allograft cartilage has the advantage of avoiding donor-site scar. Moreover, it provides the same benefits as autologous costal cartilage with comparable complication rate. Therefore, it

  16. Reasons for mini-implants failure: choosing installation site should be valued!

    Directory of Open Access Journals (Sweden)

    Alberto Consolaro

    2014-04-01

    Full Text Available Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the structures, the more delicate they are, thus offering less physical support for mini-implant placement; b Alveolar bone crests of triangular shape are more deformable, whereas those of rectangular shape are more flexible; c The bases of the alveolar processes of the maxilla and the mandible are not flexible, for this reason, they are more likely to receive mini-implants; d The more cervical a mini-implant is placed, the higher the risk of loss; the more apical a mini-implant is placed, the better its prognosis will be; e 3D evaluations play a major role in planning the use of mini-implants. Based on the aforementioned considerations, the hypotheses about mini-implant loss are as follows: 1 Deflection of maxillary and mandibular alveolar processes when mini-implants are more cervically placed; 2 Mini-implants placed too near the periodontal ligament, with normal intra-alveolar tooth movement; 3 Low bone density, low thickness and low alveolar bone volume; 4 Low alveolar cortical bone thickness; 5 Excessive pressure inducing trabecular bone microfracture; 6 Sites of higher anatomical weakness in the mandible and the maxilla; 7 Thicker gingival tissue not considered when choosing the mini-implant.

  17. Desenvolvimento e avaliação do desempenho de uma semeadora puncionadora para plantio direto de milho Development and evaluation performance of a punch planter for direct sowing of corn

    Directory of Open Access Journals (Sweden)

    Douglas R Frabetti

    2011-02-01

    Full Text Available Realizou-se este trabalho com o objetivo de desenvolver uma semeadora pontual para o semeio de milho em sistema de plantio direto e avaliar seu sistema de dosagem e distribuição de sementes. Primeiro, elaborou-se uma lista de requisitos os quais a máquina deveria atender; depois, foi feito o projeto conceitual do corpo da máquina e, em seguida, o projeto detalhado de todas as partes e conjuntos, para posterior construção do protótipo. Em bancada de ensaio avaliou-se o desempenho do sistema dosador e distribuidor de sementes, em relação à variação da velocidade e da quantidade de punções utilizada. O delineamento experimental foi em blocos casualizados arranjados em parcelas subdivididas com a parcela principal composta por 6, 9 e 12 punções e a subparcela sendo quatro rotações da roda dosadora correspondentes às velocidades de deslocamento de 4, 6, 8 e 10 km h-1. De modo geral, tanto o aumento da velocidade como do número de punções nas rodas, diminuiu o número de duplas e aumentou o número de faltas, porém a diminuição do número de duplas não foi significativo quanto ao aumento do número de faltas. A semeadora exerceu desempenho satisfatório, com média geral do número de normais de 91%.The present work was accomplished to develop a punch planter to sow corn seeds in no-tillage system, and also to evaluate the performance of its seed metering and delivery systems. First of all, a requirement list was established, that the machine would have to attend. Next, the conceptual and the embodiment designs of the machine was made. Then, the detailed design of all machine parts was made and a prototype was constructed. In a testing bench the performance of the seed metering unit and its seed delivery system was assessed in relation to the punch wheel speed and the quantity of punches on the wheel. The statistical design was in random blocks arranged in sub-divided plots with the main plot made of 6, 9 and 12 punches and

  18. Congenital hypogonadotropic hypogonadism: implications of absent mini-puberty.

    Science.gov (United States)

    Dwyer, Andrew A; Jayasena, Channa N; Quinton, Richard

    2016-06-01

    The phenomenon known as "mini-puberty" refers to activation of the neonatal hypothalamo-pituitary axis causing serum concentrations of gonadotrophins and testosterone (T) to approach adult male levels. This early neonatal period is a key proliferative window for testicular germ cells and immature Sertoli cells. Although failure to spontaneously initiate (adolescent) puberty is the most evident consequence of a defective gonadotropin-releasing hormone (GnRH) neurosecretory network, absent mini-puberty is also likely to have a major impact on the reproductive phenotype of men with congenital hypogonadotrophic hypogonadism (CHH). Furthermore, the phase of male mini-puberty represents a key window-of-opportunity to identify congenital GnRH deficiency (either isolated CHH, or as part of combined pituitary hormone deficiency) in childhood. Among male neonates exhibiting "red flag" indicators for CHH (i.e. maldescended testes with or without cryptorchidism) a single serum sample (between 4-8 weeks of life) can pinpoint congenital GnRH deficiency far more rapidly and with much greater accuracy than dynamic tests performed in later childhood or adolescence. Potential consequences for missing absent mini-puberty in a male neonate include the lack of monitoring of pubertal progression/lack of progression, and the missed opportunity for early therapeutic intervention. This article will review our current understanding of the mechanisms and clinical consequences of mini-puberty. Furthermore, evidence for the optimal clinical management of patients with absent mini-puberty will be discussed.

  19. Virtual laboratory of electrical mini-grids with distributed generation

    International Nuclear Information System (INIS)

    Menezes Ramos, Vanessa; Barros Galhardo, Marcos André; Oliveira Barbosa, Claudomiro Fábio de; Tavares Pinho, João

    2015-01-01

    This paper presents a computing tool called Virtual Laboratory de Minirredes (Virtual Laboratory of Mini-grids). Using the virtual environment of the developed tool, it is possible to make remote connection/disconnection of switches and loads (resistive, inductive, capacitive and non-linear) at strategic points of the electric mini-grid with hybrid distributed generation systems (solar photovoltaic-diesel). The mini-grid has a length of about 1 km and is installed in the test area of the Grupo de Estudios e Desenvolvimento de Alternativas Exergética (GEDAE) of the Universidade Federal do Pará, located in the city of Belém, Pará, Brazil. The developed tool has communication functions with electric parameters transducers and programmable logic controllers (PLCs). This communication enables the opening and closing of contactors, resulting in different settings for the mini-grid. In addition to that, based on the proposed configuration by the user, the real-time operation status of mini-grid is presented in a graphic interface (for example, monitored electric parameters, distributed generators connected, status of disconnected switches, etc.) and the acquired data is stored. The use of the computing tool also focuses on the construction of a database, in order to obtain knowledge about the mini-grid performance under various conditions that can be set, depending on the operational strategy adopted, based on the choice of the layout, loads and power sources used in the mini-grid. (full text)

  20. Chondrocyte-seeded type I/III collagen membrane for autologous chondrocyte transplantation

    DEFF Research Database (Denmark)

    Niemeyer, Philipp; Lenz, Philipp; Kreuz, Peter C

    2010-01-01

    PURPOSE: We report the 2-year clinical results and identify prognostic factors in patients treated with autologous chondrocyte transplantation by use of a collagen membrane to seed the chondrocytes (ACT-CS). METHODS: This is a prospective study of 59 patients who were treated with ACT......-CS represents a technical modification of membrane-associated autologous chondrocyte transplantation that combines easy handling and attractive application properties with reliable clinical results 24 months after surgery, especially in patients with isolated cartilage defects. Even though the failure rate...

  1. Mini AERCam Inspection Robot for Human Space Missions

    Science.gov (United States)

    Fredrickson, Steven E.; Duran, Steve; Mitchell, Jennifer D.

    2004-01-01

    The Engineering Directorate of NASA Johnson Space Center has developed a nanosatellite-class free-flyer intended for future external inspection and remote viewing of human spacecraft. The Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) technology demonstration unit has been integrated into the approximate form and function of a flight system. The spherical Mini AERCam free flyer is 7.5 inches in diameter and weighs approximately 10 pounds, yet it incorporates significant additional capabilities compared to the 35 pound, 14 inch AERCam Sprint that flew as a Shuttle flight experiment in 1997. Mini AERCam hosts a full suite of miniaturized avionics, instrumentation, communications, navigation, imaging, power, and propulsion subsystems, including digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations including automatic stationkeeping and point-to-point maneuvering. Mini AERCam is designed to fulfill the unique requirements and constraints associated with using a free flyer to perform external inspections and remote viewing of human spacecraft operations. This paper describes the application of Mini AERCam for stand-alone spacecraft inspection, as well as for roles on teams of humans and robots conducting future space exploration missions.

  2. Development of a New Punch Head Shape to Replicate Scale-Up Issues on a Laboratory Tablet Press III: Replicating sticking phenomenon using the SAS punch and evaluation by checking the tablet surface using 3D laser scanning microscope.

    Science.gov (United States)

    Ito, Manabu; Aoki, Shigeru; Uchiyama, Jumpei; Yamato, Keisuke

    2018-04-20

    Sticking is a common observation in the scale-up stage on the punch tip using a commercial tableting machine. The difference in the total compression time between a laboratory and a commercial tableting machine is considered one of the main root causes of scale up issues in the tableting processes. The proposed Size Adjusted for Scale-up (SAS) punch can be used to adjust the consolidation and dwell times for commercial tableting machine. As a result, the sticking phenomenon is able to be replicated at the pilot scale stage. As reported in this paper, the quantification of sticking was measured using a 3D laser scanning microscope to check the tablet surface. It was shown that the sticking area decreased with the addition of magnesium stearate in the formulation, but the sticking depth was not affected by the additional amount of magnesium stearate. It is proposed that use of a 3D laser scanning microscope can be applied to evaluate sticking as a process analytical technology (PAT) tool and so sticking can be monitored continuously without stopping the machine. Copyright © 2018. Published by Elsevier Inc.

  3. Mini-chamber, an advanced protection concept for NIF

    International Nuclear Information System (INIS)

    Peterson, P.F.; Scott, J.M.

    1996-01-01

    Inertial confinement fusion (ICF) target debris and ablated near-target materials pose the primary threat to the National Ignition Facility (NIF) final optics debris shields, as well as a major challenge in future inertial fusion energy (IFE) power plants. This work discusses a NIF 'mini-chamber,' designed to mitigate the debris threat. Although the NIF base-line design protects against debris using a frost-protected target positioner and refractory first-wall coatings, the mini-chamber provides important flexibility in three areas: debris-shield protection from beyond-design basis shots (i.e. heavy hohlraums, special diagnostics, shields); fielding of large experiments with significant surface ablation; and studying key ablation and gas-dynamics issues for liquid-wall IFE power plants. Key mini-chamber modeling results are presented, followed by discussion of equipment requirements for fielding a NIF mini-chamber. 7 refs., 3 figs

  4. Mini-Implants: New Possibilities in Interdisciplinary Treatment Approaches

    Directory of Open Access Journals (Sweden)

    Biju Sebastian

    2014-01-01

    Full Text Available The introduction of mini-implants has broadened the range of tooth movements possible by fixed appliance therapy alone. The limits of fixed orthodontic treatment have become more a matter of facial appearance than anchorage. Many complex cases which would previously have required surgery or functional appliances can now be treated with fixed appliance therapy using mini-implants. A mutilated dentition case where mini-implants were used to provide anchorage for intrusion of molars and retraction of anterior teeth is reported here to illustrate this point.

  5. The Efficacy and Safety of Autologous Transfusion in Unilateral Total Knee Arthroplasty

    OpenAIRE

    Yoo, Moon-Jib; Park, Hee-Gon; Ryu, Jee-Won; Kim, Jeong-Sang

    2015-01-01

    Purpose Although allogeneic blood transfusion is the most common method of transfusion in total knee arthroplasty (TKA), there are reports showing significant decrease in the amount of allogeneic transfusion and incidence of side effects after combined use of autologous transfusion. The purpose of this study is to investigate the efficacy of using an autologous transfusion device in TKA. Materials and Methods Patients who underwent TKA at our institution from January 2003 to January 2014 were...

  6. The Effects of Biomechanical Factors to Teach Different Hook Punch Techniques in Boxing and Education Strategies

    Science.gov (United States)

    Bingul, Bergun Meric; Bulgun, Cigdem; Tore, Ozlem; Bal, Erdal; Aydin, Mensure

    2018-01-01

    The aim of this study was to investigate the effects of biomechanic factors to teach different hook punches in boxing. Eight light middleweight boxing athletes (mean age ± SD 19.00 ± 2.00 yrs, mean height ± SD 173.88 ± 3.89 cm, mean weight ± SD 64.25 ± 4.66 kg) participated in this study. Athletes performed a trial using three different hook punch…

  7. Study of neuropeptide distribution in the central nervous system by the combined use of radioimmunoassay with the neuroatomic punch technique

    International Nuclear Information System (INIS)

    Valenca, M.M.; Negro Vilar, A.

    1991-01-01

    In order to demonstrate an experimental method to study neuropeptide distribution in the central nervous system, the content of beta-endorphin present in several brain regions was determined by the combined use of radioimmunoassay with the neuroanatomic punch technique described by Palkovits. (author)

  8. Energy efficient mini bars in hotel rooms; Energieffektive minibarer til hotelvaerelser

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-12-15

    The project 'Energy-efficient mini bars for hotel rooms' is carried out from February December 2005. The project is financed by Elfor's PSO funds and also by the participants in the project, HORESTA and Teknologisk Institut. Mini bars consume up to 10% of the total electricity costs of a hotel. Therefore, the energy consumption of mini bars has been brought into focus in this project. The existing mini bar market has been analysed and measurements have been carried out on the type of mini bars that are used most often. In that way, energy consumption, net volume, energy efficiency, energy labelling, noise level and cooling capacity have been determined. In the course of the project, mini bars from IndelB, Domestic and Vibocold have been tested. With regard to energy consumption, the test results showed large deviations from the consumption stated by the manufacturer. Only 1 of the 6 tested mini bars received an energy label B - the others were labelled with F or G. Therefore, there is a great potential for developing more energy efficient mini bars. A list covering the energy consumption, energy labelling, noise level etc. of the tested mini bars and a guide to new purchases can be found on HORESTA's homepage www.horesta.dk. (au)

  9. Recovery of autologous sickle cells by hypotonic wash.

    Science.gov (United States)

    Wilson, Emily; Kezeor, Kelly; Crosby, Monica

    2018-01-01

    It is important to isolate autologous red blood cells (RBCs) from transfused RBCs in samples from recently transfused patients to ensure that accurate serologic results are obtained. Typically, this isolation can be performed using methods that separate patient reticulocytes from transfused, older donor RBCs. Patients with sickle cell disease (SCD), however, characteristically have RBCs with altered membrane and morphological features, causing their RBCs to take on a sickle-shape appearance different from the biconcave disc-shape appearance of "normal" RBCs. These characteristics enable the use of hypotonic saline solution to lyse normal RBCs while allowing "sickle cells" to remain intact. Because many patients with SCD undergo frequent transfusions to treat their condition, the use of hypotonic saline solution provides a rapid method to obtain autologous RBCs for serologic testing from this patient population using standard laboratory equipment and supplies.

  10. Autologous transplantation of the internal limiting membrane for refractory macular holes.

    Science.gov (United States)

    Morizane, Yuki; Shiraga, Fumio; Kimura, Shuhei; Hosokawa, Mio; Shiode, Yusuke; Kawata, Tetsuhiro; Hosogi, Mika; Shirakata, Yukari; Okanouchi, Toshio

    2014-04-01

    To determine the effectiveness of autologous transplantation of the internal limiting membrane (ILM) for refractory macular holes. Prospective, interventional case series. Ten eyes of 10 consecutive patients who underwent autologous transplantation of the ILM for the treatment of refractory macular holes were studied. The primary diseases in these patients were large idiopathic macular holes that had existed for more than 1 year (4 eyes), a traumatic macular hole (1 eye), myopic foveoschisis (2 eyes), foveoschisis resulting from pit-macular syndrome (2 eyes), and proliferative diabetic retinopathy (1 eye). Apart from the 5 eyes with idiopathic or traumatic macular holes, macular holes developed in the other 5 eyes after initial vitrectomies with ILM removal. In all eyes, regular macular hole surgery failed to achieve closure. The main outcome measures used in this study were macular hole closure and best-corrected visual acuity (BCVA). Macular holes were closed successfully in 9 eyes (90%) after autologous transplantation of the ILM. The postoperative BCVAs were significantly better than the preoperative BCVAs (P = .007, paired t test). Postoperative BCVAs improved by more than 0.2 logarithm of the minimal angle of resolution units in 8 eyes (80%) and were unchanged in 2 eyes (20%). Although this is a pilot study, the results suggest that autologous transplantation of the ILM may contribute to improved anatomic and visual outcomes in the treatment of refractory macular holes and may warrant further investigation. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Development on mini X-ray diode

    International Nuclear Information System (INIS)

    Jiang Shaoen; Sun Kexu; Peng Nengling; Huang Tianxuan; Cui Yanli; Yi Rongqing; Chen Jiusen

    2004-01-01

    The mini X-ray diode (M-XRD) was developed, and was used in mini soft X-ray spectrometer. Compared with traditional XRD, M-XRD's volume reduces to 1/30. M-XRD's property was experimentally examined on Shenguang II laser facility. The experimental results indicated that the temporal response and sensitivity of M-XRD are basically consistent with traditional XRD. The equivalent circuit of XRD was analyzed, and its response time and linear saturated current were calculated. (authors)

  12. Mini Tracheostomy for Obstructive Sleep Apnea: An Evidence Based Proposal

    Science.gov (United States)

    Camacho, Macario; Zaghi, Soroush; Chang, Edward T.; Song, Sungjin A.; Szelestey, Blake; Certal, Victor

    2016-01-01

    Objective. To search for articles evaluating the use of tracheostomies (either permanent stomas or tracheostomy tubes) in adult obstructive sleep apnea (OSA) patients and to evaluate the potential for the use of mini tracheostomies as treatment for OSA. Study Design. Systematic review. Methods. Nine databases were searched from inception through July 21, 2015. Results. The overall tracheostomy search yielded 516 articles, of which eighteen studies provided polysomnographic data. No study was identified (empty review) for the use of mini tracheostomies for treating OSA. The mini tracheostomy search yielded ninety-five articles which describe findings for either mini tracheostomy kits (inner cannula diameter of 4 mm) or the performance of mini tracheotomies. Six articles described the use of mini tracheostomies as a temporary procedure to relieve acute upper airway obstruction and none described the use for OSA. For tracheostomy stomal sites, suturing the skin directly to the tracheal rings with defatting can minimize stomal site collapse. The smallest tracheostomy stomal size that can successfully treat OSA has not been described. Conclusion. Mini tracheostomies as small as 4 mm have been successfully used in the short term to relieve upper airway obstruction. Given that polysomnography data are lacking, additional research is needed. PMID:26925105

  13. Mini Tracheostomy for Obstructive Sleep Apnea: An Evidence Based Proposal

    Directory of Open Access Journals (Sweden)

    Macario Camacho

    2016-01-01

    Full Text Available Objective. To search for articles evaluating the use of tracheostomies (either permanent stomas or tracheostomy tubes in adult obstructive sleep apnea (OSA patients and to evaluate the potential for the use of mini tracheostomies as treatment for OSA. Study Design. Systematic review. Methods. Nine databases were searched from inception through July 21, 2015. Results. The overall tracheostomy search yielded 516 articles, of which eighteen studies provided polysomnographic data. No study was identified (empty review for the use of mini tracheostomies for treating OSA. The mini tracheostomy search yielded ninety-five articles which describe findings for either mini tracheostomy kits (inner cannula diameter of 4 mm or the performance of mini tracheotomies. Six articles described the use of mini tracheostomies as a temporary procedure to relieve acute upper airway obstruction and none described the use for OSA. For tracheostomy stomal sites, suturing the skin directly to the tracheal rings with defatting can minimize stomal site collapse. The smallest tracheostomy stomal size that can successfully treat OSA has not been described. Conclusion. Mini tracheostomies as small as 4 mm have been successfully used in the short term to relieve upper airway obstruction. Given that polysomnography data are lacking, additional research is needed.

  14. Revisiting the stability of mini-implants used for orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Chung-Chen Jane Yao

    2015-11-01

    Conclusion: This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly.

  15. [Penile augmentation and elongation using autologous dermal-fat strip grafting].

    Science.gov (United States)

    Yang, Zhe; Li, Yang-qun; Tang, Yong; Chen, Wen; Li, Qiang; Zhou, Chuan-de; Zhao, Mu-xin; Hu, Chun-mei

    2012-05-01

    To investigate the effect of autologous dermal-fat strip grafting in penile augmentation and elongation. From May 2004 to December 2010, 24 patients underwent penile enhancement with free dermal-fat strip grafting. Through suprapubic incision, the superior suspensory ligament and part deep suspensory ligament are cutted off to lengthen the penis. The resulted dead space is filled with the autologous dermal-fat strip (6.0-9.5 cm in length, 1.2-1.5 cm in width and 0.6-0.8 cm in depth) to enhance the penis. Primary healing was achieved in 23 cases. Incisional fat liquefaction happened in one case which healed after dressing change. The penile appearance was satisfactory both at rest or erection. The penile length and circumference increased by 2.5-4.8 cm (average, 3.2 cm) and 1.8-3.0 cm (average, 2.4 cm), respectively. 18 patients were followed up for 3 months to 5 years. All the patients were satisfactory on the cosmetic and functional results. No complication happened. It is safe and effective for penile augmention and elongation with autologous dermal-fat strip grafting and disconnection of penile suspensory ligament.

  16. Osteoarthritis treatment using autologous conditioned serum after placebo

    NARCIS (Netherlands)

    Rutgers, Marijn; Creemers, Laura B; Auw Yang, Kiem Gie; Raijmakers, Natasja J H; Dhert, Wouter J A; Saris, Daniel B F

    BACKGROUND AND PURPOSE: Autologous conditioned serum (ACS) is a disease-modifying drug for treatment of knee osteoarthritis, and modest superiority over placebo was reported in an earlier randomized controlled trial (RCT). We hypothesized that when given the opportunity, placebo-treated patients

  17. Berkeley mini-collider

    International Nuclear Information System (INIS)

    Schroeder, L.S.

    1984-06-01

    The Berkeley Mini-Collider, a heavy-ion collider being planned to provide uranium-uranium collisions at T/sub cm/ less than or equal to 4 GeV/nucleon, is described. The central physics to be studied at these energies and our early ideas for a collider detector are presented

  18. Comparative analysis of autologous blood transfusion and allogeneic blood transfusion in surgical patients

    OpenAIRE

    Long, Miao-Yun; Liu, Zhong-Han; Zhu, Jian-Guang

    2014-01-01

    Objective: To investigate application effects of autologous blood transfusion and allogeneic blood transfusion in surgically treated patients receiving spine surgery, abdomen surgery and ectopic pregnancy surgery. Methods: 130 patients who would undergo selective operations were divided into autologous transfusion group and allogeneic transfusion group. Both groups received the same anesthesia, and there was no significant difference in transfusion volume or fluid infusion volume. Results: Th...

  19. Perlindungan Hukum Hak Kekayaan Intelektual (Hki) Dalam Waralaba Retail Mini Market Di Yogyakarta Mini Market Di Yogyakarta

    OpenAIRE

    Hariyanto Hariyanto, S.H., M.KN

    2009-01-01

    The Law Protection Intellectual Property Right in Mini Market Retail Franchise in YogyakartaFranchise business is more happening in Indonesia. This fast development indicates an interesting investment which on the same time helps the business subjects in starting their own business with a low risk. The franchise business which commonly stable is retail business. One of retail business which serves the main needs and daily needs is mini market Alfamart and Indomaret.This research aims to ident...

  20. Autologous fat graft as treatment of post short stature surgical correction scars.

    Science.gov (United States)

    Maione, Luca; Memeo, Antonio; Pedretti, Leopoldo; Verdoni, Fabio; Lisa, Andrea; Bandi, Valeria; Giannasi, Silvia; Vinci, Valeriano; Mambretti, Andrea; Klinger, Marco

    2014-12-01

    Surgical limb lengthening is undertaken to correct pathological short stature. Among the possible complications related to this procedure, painful and retractile scars are a cause for both functional and cosmetic concern. Our team has already shown the efficacy of autologous fat grafting in the treatment of scars with varying aetiology, so we decided to apply this technique to scars related to surgical correction of dwarfism. A prospective study was conducted to evaluate the efficacy of autologous fat grafting in the treatment of post-surgical scars in patients with short-limb dwarfism using durometer measurements and a modified patient and observer scar assessment scale (POSAS), to which was added a parameter to evaluate movement impairment. Between January 2009 and September 2012, 36 children (28 female and 8 male) who presented retractile and painful post-surgical scars came to our unit and were treated with autologous fat grafting. Preoperative and postoperative mean durometer measurements were analysed using the analysis of variance (ANOVA) test and POSAS parameters were studied using the Wilcoxon rank sum test. There was a statistically significant reduction in all durometer measurements (p-value treatment with autologous fat grafting. Surgical procedures to camouflage scars on lower limbs are not often used as a first approach and non-surgical treatments often lead to unsatisfactory results. In contrast, our autologous fat grafting technique in the treatment of post-surgical scars has been shown to be a valuable option in patients with short-limb dwarfism. There was a reduction of skin hardness and a clinical improvement of all POSAS parameters in all patients treated. Moreover, the newly introduced POSAS parameter appears to be reliable and we recommend that it is included to give a more complete evaluation of patient perception. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Use of autologous and microsurgical breast reconstruction by U.S. plastic surgeons.

    Science.gov (United States)

    Kulkarni, Anita R; Sears, Erika Davis; Atisha, Dunya M; Alderman, Amy K

    2013-09-01

    Concern exists that plastic surgeons are performing fewer autologous and microsurgical breast reconstructions, despite superior long-term outcomes. The authors describe the proportion of U.S. plastic surgeons performing these procedures and evaluate motivating factors and perceived barriers. A random national sample of American Society of Plastic Surgeons members was surveyed (n = 325; response rate, 76 percent). Surgeon and practice characteristics were assessed, and two multiple logistic regression models were created to evaluate factors associated with (1) high-volume autologous providers and (2) microsurgical providers. Qualitative assessments of motivating factors and barriers to microsurgery were also performed. Fewer than one-fifth of plastic surgeons perform autologous procedures for more than 50 percent of their breast cancer patients, and only one-quarter perform any microsurgical breast reconstruction. Independent predictors of a high-volume autologous practice include involvement with resident education (odds ratio, 2.57; 95 percent CI, 1.26 to 5.24) and a microsurgical fellowship (odds ratio, 2.09; 95 percent CI, 1.04 to 4.27). Predictors of microsurgical breast reconstruction include involvement with resident education (odds ratio, 6.8; 95 percent CI, 3.32 to 13.91), microsurgical fellowship (odds ratio, 2.4; 95 percent CI, 1.16 to 4.95), and high breast reconstruction volume (odds ratio, 6.68; 95 percent CI, 1.76 to 25.27). The primary motivator for microsurgery is superior outcomes, and the primary deterrents are time and reimbursement. The proportion of U.S. plastic surgeons with a high-volume autologous or microsurgical breast reconstruction practice is low. Involvement with resident education appears to facilitate both, whereas time constraints and reimbursement are primary deterrents. Future efforts should focus on improving the feasibility and accessibility of all types of breast reconstruction.

  2. Orthodontic mechanics using mini-implant measured by FBG

    Science.gov (United States)

    Trannin, Pamela G.; Milczewski, Maura S.; de Oliveira, Walmir; Guariza Filho, Odilon; Lopes, Stephani C. P. S.; Kalinowski, Hypolito J.

    2015-07-01

    The magnitude of the force generated during orthodontic mechanics anchored in mini-implant in a maxilla model was analyzed. Data was collected during the insertion of the mini-implant and at the moment of applying forces to the structure of the maxilla and dentition. To obtain quantitative results, the Fibre Bragg Gratings (FBG) were inserted in an elastomeric material reproducing a maxilla model. It was observed levels of forces of approximately 3,78N next to the root of first premolar by the insertion of the mini-implant and different levels of the force to different orthodontic mechanics applied on the dental system.

  3. Initial validation of the Mini-Mental Adjustment to Cancer (Mini-MAC) scale: study of Portuguese end-of-life cancer patients.

    Science.gov (United States)

    Pereira, Filomena Moreira Pinto; Santos, Célia Samarina Vilaça de Brito

    2014-10-01

    The Mini-Mental Adjustment to Cancer Scale (Mini-MAC) is a 29-item instrument designed to evaluate the responses developed by cancer patients during their mental adjustment to diagnosis and treatment. This study aims to validate the Mini-Mental Adjustment to Cancer Scale (Mini-MAC) translated and adapted to the Portuguese language and culture, in end-of-life cancer patients receiving palliative care. The instrument was administered to 346 Portuguese end-of-life cancer patients, receiving care through outpatient visits or admitted into palliative care units, without cognitive symptoms and with symptoms under control. A cross-sectional validation study using orthogonal rotation through the varimax method followed by convergent and discriminant validity. The analysis of the main components confirms the existence of five factors, demonstrating the validity of the construct, with good internal consistency in the subscales and Cronbach's alpha values between 0.78 and 0.93. Good test-retest reliability was also found, and r values for subscales ranged from 0.62 to 0.99. The instrument proved to be a reliable, valid and sensitive measure in the study of mental adjustment of Portuguese end-of-life patients with cancer receiving palliative care. Nurses can use the Mini-MAC Scale in research and clinical practice in order to evaluate the mental adjustment of Portuguese end-of-life cancer patients receiving palliative care. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Maximum atmosphere at the Mini Atomiades

    CERN Multimedia

    Rachel Bray, Atomiades organizer team

    2016-01-01

    CERN Clubs Coordination Committee and CERN Staff Association host the ASCERI Mini Atomiades June 2016.   The CERN team won the tennis tournament for the Mini Atomiades 2016. (Photo: Erwin Van Hove) Over 180 participants from 10 different European Scientific Research Institutes came together on the first weekend of June in Divonne-les-Bains to take part in the ASCERI Sport & Science Mini Atomiades. Sports men and women from Belgium, Germany, France, Hungary, Russia and Switzerland battled it out in four different tournaments for medals, cups and, above all, lots of fun. The four disciplines included football, golf, tennis and a 10km race. CERN was victorious in tennis, golf and the men's and women's 10km, and despite the CERN football team putting up an excellent fight against some very strong teams they came almost last (we cannot win everything, can we?). But CERN were the clear winners for team spirit, community and camaraderie, as confirmed by all the comp...

  5. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  6. Outcomes of Autologous Fascia Pubovaginal Sling for Patients with Transvaginal Mesh Related Complications Requiring Mesh Removal.

    Science.gov (United States)

    McCoy, Olugbemisola; Vaughan, Taylor; Nickles, S Walker; Ashley, Matt; MacLachlan, Lara S; Ginsberg, David; Rovner, Eric

    2016-08-01

    We reviewed the outcomes of the autologous fascial pubovaginal sling as a salvage procedure for recurrent stress incontinence after intervention for polypropylene mesh erosion/exposure and/or bladder outlet obstruction in patients treated with prior transvaginal synthetic mesh for stress urinary incontinence. In a review of surgical databases at 2 institutions between January 2007 and June 2013 we identified 46 patients who underwent autologous fascial pubovaginal sling following removal of transvaginal synthetic mesh in simultaneous or staged fashion. This cohort of patients was evaluated for outcomes, including subjective and objective success, change in quality of life and complications between those who underwent staged vs concomitant synthetic mesh removal with autologous fascial pubovaginal sling placement. All 46 patients had received at least 1 prior mesh sling for incontinence and 8 (17%) had received prior transvaginal polypropylene mesh for pelvic organ prolapse repair. A total of 30 patients underwent concomitant mesh incision with or without partial excision and autologous sling placement while 16 underwent staged autologous sling placement. Mean followup was 16 months. Of the patients 22% required a mean of 1.8 subsequent interventions an average of 6.5 months after autologous sling placement with no difference in median quality of life at final followup. At last followup 42 of 46 patients (91%) and 35 of 46 (76%) had achieved objective and subjective success, respectively. There was no difference in subjective success between patients treated with a staged vs a concomitant approach (69% vs 80%, p = 0.48). Autologous fascial pubovaginal sling placement after synthetic mesh removal can be performed successfully in patients with stress urinary incontinence as a single or staged procedure. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Finite-Element Modeling of Timber Joints with Punched Metal Plate Fasteners

    DEFF Research Database (Denmark)

    Ellegaard, Peter

    2006-01-01

    The focus of this paper is to describe the idea and the theory behind a finite-element model developed for analysis of timber trusses with punched metal plate fasteners (nail plates). The finite-element model includes the semirigid and nonlinear behavior of the joints (nonlinear nail and plate...... elements) and contact between timber beams, if any (bilinear contact elements). The timber beams have linear-elastic properties. The section forces needed for design of the joints are given directly by the finite-element model, since special elements are used to model the nail groups and the nail plate...... the behavior of the joints very well at lower load levels. At higher load levels the stiffness is overestimated due to development of cracks in the timber and the linear-elastic timber properties in the finite-element model....

  8. Autologous fibrin sealant (Vivostat®) in the neurosurgical practice: Part I: Intracranial surgical procedure

    Science.gov (United States)

    Graziano, Francesca; Certo, Francesco; Basile, Luigi; Maugeri, Rosario; Grasso, Giovanni; Meccio, Flavia; Ganau, Mario; Iacopino, Domenico G.

    2015-01-01

    Background: Hemorrhages, cerebrospinal fluid (CSF) fistula and infections are the most challenging postoperative complications in Neurosurgery. In this study, we report our preliminary results using a fully autologous fibrin sealant agent, the Vivostat® system, in achieving hemostasis and CSF leakage repair during cranio-cerebral procedures. Methods: From January 2012 to March 2014, 77 patients were studied prospectively and data were collected and analyzed. Autologous fibrin sealant, taken from patient's blood, was prepared with the Vivostat® system and applied on the resection bed or above the dura mater to achieve hemostasis and dural sealing. The surgical technique, time to bleeding control and associated complications were recorded. Results: A total of 79 neurosurgical procedures have been performed on 77 patients. In the majority of cases (98%) the same autologous fibrin glue provided rapid hemostasis and dural sealing. No patient developed allergic reactions or systemic complications in association with its application. There were no cases of cerebral hematoma, swelling, infection, or epileptic seizures after surgery whether in the immediate or in late period follow-up. Conclusions: In this preliminary study, the easy and direct application of autologous fibrin sealant agent helped in controlling cerebral bleeding and in providing prompt and efficient dural sealing with resolution of CSF leaks. Although the use of autologous fibrin glue seems to be safe, easy, and effective, further investigations are strongly recommended to quantify real advantages and potential limitations. PMID:25984391

  9. Funding analysis of bilateral autologous free-flap breast reconstructions in Australia.

    Science.gov (United States)

    Sinha, Shiba; Ruskin, Olivia; McCombe, David; Morrison, Wayne; Webb, Angela

    2015-08-01

    Bilateral breast reconstructions are being increasingly performed. Autologous free-flap reconstructions represent the gold standard for post-mastectomy breast reconstruction but are resource intensive. This study aims to investigate the difference between hospital reimbursement and true cost of bilateral autologous free-flap reconstructions. Retrospective analysis of patients who underwent bilateral autologous free-flap reconstructions at a single Australian tertiary referral centre was performed. Hospital reimbursement was determined from coding analysis. A true cost analysis was also performed. Comparisons were made considering the effect of timing, indication and complications of the procedure. Forty-six bilateral autologous free-flap procedures were performed (87 deep inferior epigastric perforators (DIEPs), four superficial inferior epigastric artery perforator flaps (SIEAs) and one muscle-sparing free transverse rectus abdominis myocutaneous flap (MS-TRAM)). The mean funding discrepancy between hospital reimbursement and actual cost was $12,137 ± $8539 (mean ± standard deviation (SD)) (n = 46). Twenty-four per cent (n = 11) of the cases had been coded inaccurately. If these cases were excluded from analysis, the mean funding discrepancy per case was $9168 ± $7453 (n = 35). Minor and major complications significantly increased the true cost and funding discrepancy (p = 0.02). Bilateral free-flap breast reconstructions performed in Australian public hospitals result in a funding discrepancy. Failure to be economically viable threatens the provision of this procedure in the public system. Plastic surgeons and hospital managers need to adopt measures in order to make these gold-standard procedures cost neutral. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Autologous pubovaginal slings: back to the future or a lost art?

    Directory of Open Access Journals (Sweden)

    Bang SL

    2016-01-01

    Full Text Available Shieh-Ling Bang, Mohammed Belal Department of Urology, Queen Elizabeth Hospital, Birmingham, UK Abstract: Stress urinary incontinence (SUI is an under-diagnosed problem affecting up to 50% of women worldwide. SUI is a source of psychological distress to the individual and also imposes a financial burden to the individual and the health care system. The role of surgery in the treatment in SUI has evolved steadily in the last two decades. The synthetic mid-urethral sling and its different insertion methods have gained widespread popularity and are now the most frequently used surgical interventions for women with SUI in Europe. As the use of synthetic slings becomes more widespread, an increasing number of complications are being reported. With the recent concerns surrounding the use of synthetic transvaginal meshes in organ prolapse surgery, synthetic slings have been put under further scrutiny. It is imperative for health care providers to be aware of the current issues associated with synthetic slings and the alternative surgical options available. Traditional autologous pubovaginal slings (PVS have re-emerged as a viable alternative to synthetic slings in light of the issues with synthetic slings. The re-adoption of autologous PVS has however, been slow due to the technical difficulty of the surgery and perceived higher morbidity rates. In this article, we will discuss the various aspects of autologous PVS and its indications as an alternative to synthetic slings. We will also touch on the current evidence and controversies for synthetic mesh slings. Keywords: autologous pubovaginal sling, stress urinary incontinence, synthetic sling, erosions 

  11. Bio-artificial pleura using an autologous dermal fibroblast sheet

    Science.gov (United States)

    Kanzaki, Masato; Takagi, Ryo; Washio, Kaoru; Kokubo, Mami; Yamato, Masayuki

    2017-10-01

    Air leaks (ALs) are observed after pulmonary resections, and without proper treatment, can produce severe complications. AL prevention is a critical objective for managing patients after pulmonary resection. This study applied autologous dermal fibroblast sheets (DFS) to close ALs. For sealing ALs in a 44-year-old male human patient with multiple bullae, a 5 × 15-mm section of skin was surgically excised. From this skin specimen, primary dermal fibroblasts were isolated and cultured for 4 weeks to produce DFSs that were harvested after a 10-day culture. ALs were completely sealed using surgical placement of these autologous DFSs. DFS were found to be a durable long-term AL sealant, exhibiting requisite flexibility, elasticity, durability, biocompatibility, and usability, resulting reliable AL closure. DFS should prove to be an extremely useful tissue-engineered pleura substitute.

  12. Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Olsen, Addie Nina; Frøslev, Tobias G.

    2009-01-01

    We have implemented and validated automated methods for washing FTA Card punches containing buccal samples and subsequent PCR setup using a Sias Xantus automated liquid handler. The automated methods were controlled by worklists generated by our LabWare Laboratory Information Management System...

  13. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  14. Research progresses in treating diabetic foot with autologous stem cell transplantation

    International Nuclear Information System (INIS)

    Qin Hanlin; Gao Bin

    2010-01-01

    Because the distal arteries of lower extremities become narrowed or even occluded in diabetic foot, the clinical therapeutic results for diabetic foot have been unsatisfactory so far. Autologous stem cell transplantation that has emerged in recent years is a new, safe and effective therapy for diabetic foot, which achieves its excellent clinical success in restoring the blood supply of ischemic limb by way of therapeutic angiogenesis. Now autologous stem cell transplantation has become one of the hot points in medical research both at home and abroad, moreover, it has brought a new hope of cure to the patients with diabetic foot. (authors)

  15. Autologous dental pulp stem cells in periodontal regeneration: a case report.

    Science.gov (United States)

    Aimetti, Mario; Ferrarotti, Francesco; Cricenti, Luca; Mariani, Giulia Maria; Romano, Federica

    2014-01-01

    Histologic findings in animal models suggest that the application of dental pulp stem cells (DPSCs) may promote periodontal regeneration in infrabony defects. This case report describes the clinical and radiographic regenerative potential of autologous DPSCs in the treatment of human noncontained intraosseous defects. A chronic periodontitis patient with one vital third molar requiring extraction was surgically treated. The third molar was extracted and used as an autologous DPSCs source to regenerate the infrabony defect on the mandibular right second premolar. At the 1-year examination, the defect was completely filled with bonelike tissue as confirmed through the reentry procedure.

  16. Mini tunelizador moldável: um avanço técnico no acesso vascular para hemodiálise Mini moldable tunneler: a technical improvement for hemodialysis access

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Rossi

    2011-12-01

    cirurgias de confecção de fístula para hemodiálise. Sua versatilidade e baixo custo de produção podem levá-lo a substituir os tunelizadores rígidos utilizados na atualidade e apontam para estudos mais elaborados e com casuística adequada para avaliação do real valor do novo instrumento.BACKGROUND: Hemodialysis access fistula may involve creation of a tunnel for the accommodation of autologous vein or synthetic graft. The route and extent depend on the location of the anastomosis and fistula body.Currently, the tunnelers used are rigid metallic cylindrical structures. Various sizes and conformations may be necessary. OBJECTIVE: Testing the use of a mini universal moldable tunnel maker in hemodialysis access fistula surgical creation. METHODS: This is a pilot study. The tunneler developed consists of a cylindrical structure composed of stainless steel wire with a handle at the proximal end and dual interchangeable conical tip at the distal end. It is covered with a cylindrical sheath of polyethylene. Its technical surgical application and complications were studied during ten hemodialysis fistula creation. RESULTS: Characteristics of flexibility and conformability made possible the same mini tunnel maker to be used in various types of fistulas performed. The tapered distal tip with double diameter, interchangeable head, allowed the same apparatus to be used in autogenos and graft fistulas surgical creation. CONCLUSION: The same mini malleable tunneler was used in all fistulas, regardless of the site of anastomosis and type of fistula performed without complications and with excellent patency rate.

  17. [Construction of a capsular tissue-engineered ureteral stent seeded with autologous urothelial cells].

    Science.gov (United States)

    Tan, Haisong; Fu, Weijun; Li, Jianqiang; Wang, Zhongxin; Li, Gang; Ma, Xin; Dong, Jun; Gao, Jiangping; Wang, Xiaoxiong; Zhang, Xu

    2013-01-01

    To investigate the feasibility of constructing a capsular poly L-lactic acid (PLLA) ureteral stent seeded with autologous urothelial cells using tissue engineering methods. The capsular ureteral stent was constructed by subcutaneously embedding PLLA ureteral stent in the back of beagles for 3 weeks to induce the formation of connective tissue on the surfaces. After decellularization of the stent, the expanded autologous urothelial cells were seeded on the stent. The surface structure and cell adhesion of the stent were observed using HE staining, scanning electron microscope (SEM) and immunocytochemical staining. MTT assay was used to evaluate urothelial cell proliferation on the capsular PLLA ureteral stent and on circumferential small intestinal submucosa graft. HE staining and VIII factor immunohistochemistry revealed numerous capillaries in the connective tissue encapsulating the stent without obvious local inflammatory response. The results of SEM and immunocytochemical staining showed that the capsule contained rich collagenic fibers forming three-dimensional structures, and the seeded autologous urothelial cells could adhere and well aligned on the surface. MTT assay showed normal growth of the cells on the stent as compared with the cells grown on circumferential small intestinal submucosa graft. The capsular PLLA ureteral stent allows adhesion and proliferation of autologous urothelial cells and shows a potential in applications of constructing tissue-engineered ureter.

  18. Autologous bone marrow transplantation following chemotherapy and irradiation in dogs with spontaneous lymphomas

    International Nuclear Information System (INIS)

    Bowles, C.A.; Bull, M.; McCormick, K.; Kadin, M.; Lucas, D.

    1980-01-01

    Thirty dogs with spontaneous lymphomas were administered two to six cycles of chemotherapy and were randomized into 3 groups to receive 800 rads of total body irradiation and autologous bone marrow transplantation. Of 10 dogs irradiated after chemotherapy-induced remission and infused with remission marrow (group 1), 8 (80%) had successful grafts and experienced remissions lasting 62 to 1024 days. Of 9 dogs irradiated during remission and infused with remission marrow mixed with autologous tumor cells (group 2), 6 (66%) had remission lasting 15 to 45 days. Eleven dogs with progressive tumor growth (relapse) following chemotherapy were irradiated and infused with remission marrow (group 3). Tumor remission lasting 39 to 350 days was observed in 5 dogs (45%) in this group, and 6 dogs died in less than 30 days. Dogs in groups 1 to 3 had median survival times of 216, 60, and 45 days, respectively. The prolonged survival times for dogs in group 1 compared to dogs in groups 2 and 3 suggest that protocols involving irradiation and autologous marrow grafting in this model would be most effective when these protocols are applied to animals having a minimum tumor burden at the time of irradiation and when the grafting is done with tumor-free autologous marrow

  19. Resorbable screws for fixation of autologous bone grafts

    NARCIS (Netherlands)

    Raghoebar, GM; Liem, RSB; Bos, RRM; van der Wal, JE; Vissink, A

    The aim of this study was to evaluate the suitability of resorbable screws made of poly (D,L-lactide) acid (PDLLA) for fixation of autologous bone grafts related to graft regeneration and osseointegration of dental implants. In eight edentulous patients suffering from insufficient retention of their

  20. Experience with predonated autologous blood transfusion in open ...

    African Journals Online (AJOL)

    Objectives: To find out the practicability, the acceptability, the effectiveness and the safety level of pre-donated, autologous blood transfusion (ABT) in patients who underwent open prostatectomy. Study design: Prospective. Patients and methods: It was a prospective study carried out in Nigeria over a 5-year period.

  1. Vaccination with apoptosis colorectal cancer cell pulsed autologous ...

    African Journals Online (AJOL)

    To investigate vaccination with apoptosis colorectal cancer (CRC) cell pulsed autologous dendritic cells (DCs) in advanced CRC, 14 patients with advanced colorectal cancer (CRC) were enrolled and treated with DCs vaccine to assess toxicity, tolerability, immune and clinical responses to the vaccine. No severe toxicity ...

  2. Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants

    OpenAIRE

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 follo...

  3. Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature.

    Science.gov (United States)

    Bruchhausen, Matthias; Lapetite, Jean-Marc; Ripplinger, Stefan; Austin, Tim

    2016-12-01

    Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from -196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT volume data detailed 3D surface maps of the specimens were established. All data are open access and available from Online Data Information Network (ODIN)https://odin.jrc.ec.europa.eu. The data presented in the current work has been analyzed in the research article "On the determination of the ductile to brittle transition temperature from small punch tests on Grade 91 ferritic-martensitic steel" (M. Bruchhausen, S. Holmström, J.-M. Lapetite, S. Ripplinger, 2015) [1].

  4. Mini-mental Parkinson (MMP) as a dementia screening test: comparison with the Mini-Mental State Examination (MMSE).

    Science.gov (United States)

    Larner, Andrew J

    2012-07-01

    As populations age, screening instruments for cognitive impairment and dementia will become of increasing importance in clinical practice. Mini-Mental Parkinson (MMP), a derivative of the Mini-Mental State Examination (MMSE), was originally described as a cognitive screening instrument for use in Parkinson's disease. Its item content addresses some of the acknowledged shortcomings of the MMSE. Pragmatic use of MMP in general cognitive clinics has not previously been examined. To compare the performance of two scales, Mini-Mental Parkinson (MMP) and the Mini-Mental State Examination (MMSE), as cognitive screening instruments for dementia in a memory clinic population. MMP was administered prospectively to 201 consecutive new patient referrals independent of other tests used to establish dementia diagnosis according to standard diagnostic criteria (DSM-IV). Diagnostic utility of MMP for dementia was measured and compared with MMSE. MMP proved easy to use and acceptable to patients. Optimal test accuracy (0.86) was at MMP cutoff of ≤ 17/32, with sensitivity 0.51, specificity 0.97, positive predictive value 0.83, negative predictive value 0.87, and area under Receiver Operating Characteristic curve 0.89. Using a higher cutoff (≤ 29/32), MMP sensitivity was 1.00 with specificity 0.70. MMP scores correlated with MMSE (r = 0.93) and diagnostic agreement was high (κ = 0.85). MMP is a useful screening instrument in the memory clinic setting, with patients who fall below the designated cutoff requiring further investigation to ascertain a cause for their cognitive impairment.

  5. Mini-clinical evaluation exercise til evaluering af kommunikation og samarbejde i ambulatoriet

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Simonsen, Dorit; Bastholt, Lars

    2009-01-01

    INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation...... of communicative and cooperative skills and 2) whether mini-CEX would provide reproducible data. MATERIAL AND METHODS: Twenty-one residents were evaluated by mini-CEX by trained observers. Seventeen residents had at least two observations within a short period of time and these data were used to estimate the mini...

  6. Mini-conference and Related Sessions on Laboratory Plasma Astrophysics

    International Nuclear Information System (INIS)

    Hantao Ji

    2004-01-01

    This paper provides a summary of some major physics issues and future perspectives discussed in the Mini-Conference on Laboratory Plasma Astrophysics. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2003 Annual Meeting (October 27-31, 2003). Also included are brief summaries of selected talks on the same topic presented at two invited paper sessions (including a tutorial) and two contributed focus oral sessions, which were organized in coordination with the Mini-Conference by the same organizers

  7. Mini-conference and Related Sessions on Laboratory Plasma Astrophysics

    Energy Technology Data Exchange (ETDEWEB)

    Hantao Ji

    2004-02-27

    This paper provides a summary of some major physics issues and future perspectives discussed in the Mini-Conference on Laboratory Plasma Astrophysics. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2003 Annual Meeting (October 27-31, 2003). Also included are brief summaries of selected talks on the same topic presented at two invited paper sessions (including a tutorial) and two contributed focus oral sessions, which were organized in coordination with the Mini-Conference by the same organizers.

  8. Development of a miniaturized bulge test (small punch test) for post-irradiation mechanical property evaluation

    International Nuclear Information System (INIS)

    Eto, Motokuni; Suzuki, Masahide; Nishiyama, Yutaka; Fukaya, Kiyoshi; Jitsukawa, Shiro; Misawa, Toshihei

    1993-01-01

    To examine the effectiveness of the small punch test for evaluating strength and toughness of irradiated ferritic steels, detailed procedures are described aiming at standardization of the test. The statistical approach to analysis of the SP energy as a function of temperature for evaluation of DBTT was also reviewed. The method was then applied to neutron-irradiated ferritic steels, which included F-82, F-82H, HT-9, and 2 1/4 Cr-1Mo steel. Fluence and irradiation temperatures ranged from 2 to 12 x 10 23 n/m 2 (E ≥ 1 MeV) and from 573 to 673 K, respectively. Comparison of parameters obtained from the small punch test with the properties measured by the conventional method indicated that: (a) the 0.2% offset stress and the ultimate tensile strength at room temperature can be correlated well with the parameters, P y /(t 0 ) 2 and P max /(t 0 ) 2 , respectively. Here, P y and P max are the loads corresponding to the yield and the maximum, and t 0 is the initial thickness of a specimen; (b) fracture toughness, J IC , can be evaluated using equivalent fracture strain, anti ε qf , and the previously established relationship between these values; and (c) DBTT measured by a Charpy test can be predicted from the results of temperature dependence of SP energy determined from the area under the load-deflection curve using a statistical analysis based on a Weibull distribution

  9. Screening for Dementia in Older Adults: Comparison of Mini-Mental State Examination, Mini-Cog, Clock Drawing Test and AD8.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin

    2016-01-01

    This study was conducted to estimate screening performance of dementia screening tools including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) for older adults. 2015 participants aged 65 years or more in eastern China were enrolled. 4 screening tests were administered and scored by specifically trained psychiatrists. We used data from two-by-two tables to calculate the sensitivity, specificity, and positive and negative predictive values (PPV/NPV). Our study showed that dementia was highly prevalent among elderly in Zhejiang province. The Mini-Cog, with excellent screening characteristics and spending less time, could be considered to be used as a screening tool among communities to help to diagnose dementia early.

  10. Autologous Dendritic Cells Pulsed with Allogeneic Tumor Cell Lysate in Mesothelioma: From Mouse to Human.

    Science.gov (United States)

    Aerts, Joachim G J V; de Goeje, Pauline L; Cornelissen, Robin; Kaijen-Lambers, Margaretha E H; Bezemer, Koen; van der Leest, Cor H; Mahaweni, Niken M; Kunert, André; Eskens, Ferry A L M; Waasdorp, Cynthia; Braakman, Eric; van der Holt, Bronno; Vulto, Arnold G; Hendriks, Rudi W; Hegmans, Joost P J J; Hoogsteden, Henk C

    2018-02-15

    Purpose: Mesothelioma has been regarded as a nonimmunogenic tumor, which is also shown by the low response rates to treatments targeting the PD-1/PD-L1 axis. Previously, we demonstrated that autologous tumor lysate-pulsed dendritic cell (DC) immunotherapy increased T-cell response toward malignant mesothelioma. However, the use of autologous tumor material hampers implementation in large clinical trials, which might be overcome by using allogeneic tumor cell lines as tumor antigen source. The purpose of this study was to investigate whether allogeneic lysate-pulsed DC immunotherapy is effective in mice and safe in humans. Experimental Design: First, in two murine mesothelioma models, mice were treated with autologous DCs pulsed with either autologous or allogeneic tumor lysate or injected with PBS (negative control). Survival and tumor-directed T-cell responses of these mice were monitored. Results were taken forward in a first-in-human clinical trial, in which 9 patients were treated with 10, 25, or 50 million DCs per vaccination. DC vaccination consisted of autologous monocyte-derived DCs pulsed with tumor lysate from five mesothelioma cell lines. Results: In mice, allogeneic lysate-pulsed DC immunotherapy induced tumor-specific T cells and led to an increased survival, to a similar extent as DC immunotherapy with autologous tumor lysate. In the first-in-human clinical trial, no dose-limiting toxicities were established and radiographic responses were observed. Median PFS was 8.8 months [95% confidence interval (CI), 4.1-20.3] and median OS not reached (median follow-up = 22.8 months). Conclusions: DC immunotherapy with allogeneic tumor lysate is effective in mice and safe and feasible in humans. Clin Cancer Res; 24(4); 766-76. ©2017 AACR . ©2017 American Association for Cancer Research.

  11. Autologous fat graft in irradiated orbit postenucleation for retinoblastoma.

    Science.gov (United States)

    Klinger, Francesco; Maione, Luca; Vinci, Valeriano; Lisa, Andrea; Barbera, Federico; Balia, Laura; Caviggioli, Fabio; Di Maria, Alessandra

    2018-01-05

    Autologous fat grafting has been extensively and successfully adopted in a number of pathologic conditions in regenerative surgery especially on irradiated fields in order to improve pain symptoms and tissue trophism promoting scar release. In the present study, we report our experience with autologous fat grafting for the treatment of postirradiation fibrosis and pain on three consecutive patients undergoing orbital enucleation for locally advanced retinoblastoma (RB) and subsequent radiotherapy. We selected three consecutive patients who underwent orbital enucleation for locally advanced RB and subsequent local radiotherapy showing severe reduction in orbital volume and eyelid length and retraction due to fibrosis, spontaneous local pain exacerbated after digital pressure with no possibility to place an ocular implant. They underwent autologous fat grafting in the orbital cavity and results were evaluated by clinical examination at 5 and 14 days, and 1, 3, 6 months, and 1 year after surgery. A significant release of scar retraction, reduction of fibrosis and orbital rim contraction together with an important improvement of pain symptoms was observed in all patients. The local changes observed enabled an ease placement of an ocular prosthetic implant (implant). No local or systemic complication occurred. Fat grafting is a promising treatment for patients showing radiotherapy related complication in the orbital area and it should be adopted by all oculoplastic surgeon in order to improve pain syndrome creating the ideal local conditions for the placement of an ocular prosthetic implant.

  12. Surgical Patients\\' Knowledge and Acceptance of Autologous Blood ...

    African Journals Online (AJOL)

    Background: Homologous blood transfusion carries a well-documented array of risks especially in an HIV endemic environment like Nigeria. It is therefore imperative to consider other forms of restoring blood volume in surgical patients. Autologous blood transfusion (ABT) is one of the ways the problem of HIV transmission ...

  13. Systemic levels of metallic ions released from orthodontic mini-implants.

    Science.gov (United States)

    de Morais, Liliane Siqueira; Serra, Glaucio Guimarães; Albuquerque Palermo, Elisabete Fernandes; Andrade, Leonardo Rodrigues; Müller, Carlos Alberto; Meyers, Marc André; Elias, Carlos Nelson

    2009-04-01

    Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibia. Twenty-three New Zealand rabbits were randomly divided into 4 groups: control, 1 week, 4 weeks, and 12 weeks. Four orthodontic mini-implants were placed in the left proximal tibia of 18 rabbits. Five control rabbits had no orthodontic mini-implants. After 1, 4, and 12 weeks, the rabbits were killed, and the selected tissues were extracted and prepared for analysis by graphite furnace atomic absorption spectrophotometry. Low amounts of Ti, Al, and V were detectable in the 1-week, 4-weeks, and 12-weeks groups, confirming that release of these metals from the mini-implants occurs, with diffusion and accumulation in remote organs. Despite the tendency of ion release when using the Ti alloy as orthodontic mini-implants, the amounts of metals detected were significantly below the average intake of these elements through food and drink and did not reach toxic concentrations.

  14. Measuring mental health in the clinical setting: what is important to service users? The Mini-Service user Recovery Evaluation scale (Mini-SeRvE).

    Science.gov (United States)

    Barber, Joanna M; Parsons, Helen; Wilson, Carol A; Cook, Christopher C H

    2017-12-01

    Since 2001, a policy of positive mental health recovery has been promoted in the UK, with service user involvement. This has not been easy to implement in the clinical setting. To develop and validate a brief self-report, service user-designed, outcome measure (Mini-SeRvE), for clinical use, including spiritual and religious issues. From the previously developed Service user Recovery Evaluation scale (SeRvE), 15 questions were selected for Mini-SeRvE which was self-completed by 207 people; 100 service users and, for comparison, 107 staff. Results were analysed using SPSS software (SPSS Inc., Chicago, IL). Mini-SeRvE is reliable, Cronbach's alpha 0.852. Correlation with another recovery scale, Mental Health Recovery Measure, was high, r = 0.819. Three reliable subscales emerged; existential well-being (EWB), mental ill-being (MIB) and religious well-being (RWB). Scores of the EWB and MIB subscales were higher for staff, consistent with higher mental well-being. Religious well-being scores were higher in service users, who also rated religion as more important to them. Mini-SeRvE is a valid measure of service user recovery. The importance of religion/spiritual belief for our users is highlighted, this being reflected in the subject matter of Mini-SeRvE. Mini-SeRvE assessments could show individual priorities, evaluate therapy and aid clinical decision-making.

  15. A Nationwide Analysis of Cost Variation for Autologous Free Flap Breast Reconstruction.

    Science.gov (United States)

    Billig, Jessica I; Lu, Yiwen; Momoh, Adeyiza O; Chung, Kevin C

    2017-11-01

    Cost variation among hospitals has been demonstrated for surgical procedures. Uncovering these differences has helped guide measures taken to reduce health care spending. To date, the fiscal consequence of hospital variation for autologous free flap breast reconstruction is unknown. To investigate factors that influence cost variation for autologous free flap breast reconstruction. A secondary cross-sectional analysis was performed using the Healthcare Cost and Utilization Project National Inpatient Sample database from 2008 to 2010. The dates of analysis were September 2016 to February 2017. The setting was a stratified sample of all US community hospitals. Participants were female patients who were diagnosed as having breast cancer or were at high risk for breast cancer and underwent autologous free flap breast reconstruction. Variables of interest included demographic data, hospital characteristics, length of stay, complications (surgical and systemic), and inpatient cost. The study used univariate and generalized linear mixed models to examine associations between patient and hospital characteristics and cost. A total of 3302 patients were included in the study, with a median age of 50 years (interquartile range, 44-57 years). The mean cost for autologous free flap breast reconstruction was $22 677 (interquartile range, $14 907-$33 391). Flap reconstructions performed at high-volume hospitals were significantly more costly than those performed at low-volume hospitals ($24 360 vs $18 918, P Logistic regression demonstrated that hospital volume correlated with increased cost (Exp[β], 1.06; 95% CI, 1.02-1.11; P = .003). Fewer surgical complications (16.4% [169 of 1029] vs 23.7% [278 of 1174], P cost variation among patients undergoing autologous free flap breast reconstruction. Experience, as measured by a hospital's volume, provides quality health care with fewer complications but is more costly. Longer length of stay contributed to regional

  16. Taman Mini Indonesia Indah sebagai Bagian dari Fenomena Taman Budaya Dunia

    Directory of Open Access Journals (Sweden)

    Anak Agung Ayu Wulandari

    2012-10-01

    Full Text Available Cultural display in an open space or known as cultural parks appears rapidly as a worldwide phenomenon. From the European model which has a strong educational value, to the Asian parks which not only has educational function, but also has recreational purposes. So many types and characteristics of these parks, researches give them different names, thodse are Open-air museums, Ethnographic Theme Parks or even Theme Parks. Taman Mini Indonesia Indah as a part of this phenomenon was built first and foremost for educational purposes, therefore Taman Mini can be considered as an open-air museum. However, since Taman Mini also has recreational purposes, others can argue that Taman Mini is a theme park. Qualitative method will be used for this research, through observation to Taman Mini Indonesia Indah, followed by extensive literature review. With these data along with a table which points out the distinction between museum and theme parks. It can  be concluded that Taman Mini is a Theme Park.   

  17. Refining MARGINS Mini-Lessons Using Classroom Observations

    Science.gov (United States)

    Iverson, E. A.; Manduca, C. A.; McDaris, J. R.; Lee, S.

    2009-12-01

    One of the challenges that we face in developing teaching materials or activities from research findings is testing the materials to determine that they work as intended. Traditionally faculty develop material for their own class, notice what worked and didn’t, and improve them the next year. However, as we move to a community process of creating and sharing teaching materials, a community-based process for testing materials is appropriate. The MARGINS project has piloted such a process for testing teaching materials and activities developed as part of its mini-lesson project (http://serc.carleton.edu/margins/index.html). Building on prior work developing mechanisms for community review of teaching resources (e.g. Kastens, 2002; Hancock and Manduca, 2005; Mayhew and Hall, 2007), the MARGINS evaluation team developed a structured classroom observation protocol. The goals of field testing are to a) gather structured, consistent feedback for the lesson authors based on classroom use; b) guide reviewers of these lessons to reflect on research-based educational practice as a framework for their comments; c) collect information on the data and observations that the reviewer used to underpin their review; d) determine which mini-lessons are ready to be made widely available on the website. The protocol guides faculty observations on why they used the activity, the effectiveness of the activity in their classroom, the success of the activity in leading to the desired learning, and what other faculty need to successfully use the activity. Available online (http://serc.carleton.edu/margins/protocol.html), the protocol can be downloaded and completed during instruction with the activity. In order to encourage review of mini-lessons using the protocol, a workshop focused on review and revision of activities was held in May 2009. In preparation for the workshop, 13 of the 28 participants chose to field test a mini-lesson prior to the workshop and reported that they found this

  18. Specific Factors Influence the Success of Autologous and Allogeneic Hematopoietic Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    Thissiane L. Gonçalves

    2009-01-01

    Full Text Available Successful hematopoietic stem cell transplantation (HSCT, both autologous and allogeneic, requires a rapid and durable engraftment, with neutrophil (>500/µL and platelet (>20,000/µL reconstitution. Factors influencing engraftment after autologous or allogeneic HSCT were investigated in 65 patients: 25 autologous peripheral stem cell transplantation (PBSCT and 40 allogeneic bone marrow transplantation (BMT patients. The major factor affecting engraftment was the graft source for HSCT. Neutrophil and platelet recovery were more rapid in autologous PBSCT than in allogeneic BMT [neutrophil occurring in median on day 10.00 (09.00/11.00 and 19.00 (16.00/23.00 and platelet on day 11.00 (10.00/13.00 and 21.00 (18.00/25.00, respectively; p < 0.0001]. The type of disease also affected engraftment, where multiple myeloma (MM and lymphoma showed faster engraftment when compared with leukemia, syndrome myelodysplastic (SMD and aplastic anemia (AA and MM presented the best overall survival (OS in a period of 12 months. Other factors included the drug used in the conditioning regimen (CR, where CBV, melphalan (M-200 and FluCy showed faster engraftment and M-200 presented the best OS, in a period of 12 months and age, where 50–59 years demonstrated faster engraftment. Sex did not influence neutrophil and platelet recovery.

  19. A mini-microscope for in situ monitoring of cells.

    Science.gov (United States)

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R; Hamilton, Geraldine A; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E; Khademhosseini, Ali

    2012-10-21

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost.

  20. Complete overdentures retained by mini implants: A systematic review.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Júnior, Joel Ferreira Santiago; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    2017-02-01

    The purpose of this systematic review was to evaluate the use of mini implants to retain complete overdentures in terms of survival rates of mini implants, marginal bone loss, satisfaction, and quality of life. This report followed the PRISMA Statement and PICO question. This review has been registered at PROSPERO under the number CRD42016036141. Two independent reviewers performed a comprehensive search of studies published until September 2016 and listed in the PubMed/MEDLINE, Embase, and The Cochrane Library databases. The focused question was: is the use of mini implants feasible for prosthodontic rehabilitation with complete overdentures? The 24 studies selected for review evaluated 1273 patients whose mean age was 65.93 years; these patients had received 2494 mini implants and 386 standard implants for retaining overdenture prosthesis. The mean follow-up time was 2.48 years (range: 1-7 years). There was a higher survival rate of mini implants (92.32%). More frequent failures for maxillary (31.71%) compared with mandibular arches (4.89%). The majority of studies revealed marginal bone loss values similar to those of standard implants (overdenture prosthesis is considered an alternative treatment when standard treatment is not possible, since it presents high survival rates, acceptable marginal bone loss, and improvements in variables related to satisfaction and quality of life. Based on the results of this study, the use of a minimum 4 and 6 mini implants can be considered a satisfactory treatment option for rehabilitation of the mandibular and maxillary arches respectively with a complete overdenture. Copyright © 2016. Published by Elsevier Ltd.

  1. Study of the mechanical properties of the electric power station components: the punch test; Etude des proprietes mecaniques des composants de centrales thermiques: l'essai punch test

    Energy Technology Data Exchange (ETDEWEB)

    Isselin, J

    2003-03-15

    The aging of the electric production park implies an increasing need of knowledge concerning the evolution of the mechanical properties of its components. With regard to this problem, the availability in material is more and more small. This work proposes to characterize these properties through a mechanical test called Punch test. The main characteristic of this test is to use very small volume samples. The development of this test has been carried out by the study of a 15 MDV 4-05 steel coming from a steam drum of a thermal power plant after 145000 hours of service. At first, we have measured the influence of the parameters of this test. Then, the study has dealt more particularly on the transition temperature of the material. With the finite element simulation method, the strain hardening coefficient of the material has been determined. (O.M.)

  2. Mini-implantes ortodônticos como auxiliares da fase de retração anterior Orthodontic mini-implants assisting the anterior retraction phase

    Directory of Open Access Journals (Sweden)

    Carlo Marassi

    2008-10-01

    Full Text Available INTRODUÇÃO: os mini-implantes ortodônticos se estabeleceram como um importante método de ancoragem e vêm auxiliando os ortodontistas nas várias etapas do tratamento ortodôntico, eliminando, em grande parte, a necessidade de colaboração dos pacientes e tornando os resultados mais previsíveis. OBJETIVO: este artigo descreve os principais aspectos do uso dos mini-implantes como auxiliares da fase de retração anterior, trazendo considerações sobre suas indicações, quantidade de movimentação dos dentes anteriores, os vetores de força de retração, o controle vertical, o posicionamento dos mini-implantes, os tipos de apoio na região anterior e a força a ser utilizada. São citados os sítios de instalação mais usados para a retração anterior e abordados fatores que deverão ser controlados durante o fechamento de espaço. Por fim, são citadas algumas considerações clínicas sobre o uso dos mini-implantes nessa importante fase do tratamento ortodôntico.INTRODUCTION: The use of orthodontic mini-implants has settled as an important anchorage method and is aiding the orthodontists in the several stages of the treatment, largely eliminating the need of patients' compliance, and turning the results more predictable. AIM: This article describes the main aspects of the use of mini-implants as auxiliaries on the retraction phase of the anterior teeth, bringing considerations about their indications, amount of movement of the anterior teeth, the vectors of retraction force, the vertical control and evaluation of the incisors vestibulolingual tipping, the positioning of the mini-implants, the support types in the anterior area and the force to be applied. The placement sites best used for the anterior retraction are mentioned, and the factors that should be controlled during the space closure are approached. Lastly, some clinical considerations on the use of mini-implants in such important phase of the orthodontic treatment are

  3. The Mini-Cog versus the Mini-Mental State Examination and the Clock Drawing Test in daily clinical practice: screening value in a German Memory Clinic.

    Science.gov (United States)

    Milian, Monika; Leiherr, Anna-Maria; Straten, Guido; Müller, Stephan; Leyhe, Thomas; Eschweiler, Gerhard W

    2012-05-01

    The aim of this study was to compare the screening value of the Mini-Cog, Clock Drawing Test (CDT), Mini-Mental State Examination (MMSE) and the algorithm MMSE and/or CDT to separate elderly people with dementia from healthy depending on test time, type and severity of dementia, and demographic variables in a German Memory Clinic. Data from a heterogeneous patient sample and healthy participants (n = 502) were retrospectively analyzed. Of the 438 patients with dementia, 49.1% of the dementia diagnoses were Alzheimer's dementia and 50.9% were non-Alzheimer's dementia. Sixty-four participants were classified as cognitively unimpaired. The CDT and an extraction of the 3-item recall of the MMSE were used to constitute the Mini-Cog algorithm. Overall, the Mini-Cog showed significantly higher discriminatory power (86.8%) than the MMSE (72.6% at a cut-off ≤ 24 and 79.2% at ≤ 25, respectively) and CDT (78.1%) (each p 0.05). The specificity of the Mini-Cog (100.0%) was similar to that of the MMSE (100.0% for both cut-offs) and CDT (96.9%) (p = 0.154). For all age and educational groups the Mini-Cog outmatched the CDT and MMSE, and was less affected by education than MMSE and less susceptible for the dementia stage than the CDT. The Mini-Cog proved to have superior discriminatory power than either CDT or MMSE and is demonstrated to be a valid "short" screening instrument taking 3 to 4 minutes to administer in the geriatric setting.

  4. Complications Following Autologous Latissimus Flap Breast Reconstruction

    Directory of Open Access Journals (Sweden)

    Mufid Burgić

    2010-02-01

    Full Text Available Use of an autologous latissimus flap in breast reconstruction accounts for a supple and natural look of reconstructed breast. Most common postoperative complication, seroma, became more of a rule then an exception when it comes to postoperative evaluation of the patients who underwent this reconstructive procedure. A retrospective study analysing and evaluating different complication rates in 20 patients who underwent breast reconstruction by autologous latissimus flap, was conducted. All patients included in the study were operated at the Department of plastic surgery of Hôpital Civil in Strasbourg, France, between 1996 and 2008. The complication rates were noted as follows: seroma in 19 of our 20 patients (95%, late hypertrophic scarring in 3 patients (15%, postoperative surgical site hematoma in 3 patients (15%, and 2 patients (10% presented postoperative chronic back pain. Different options used in seroma treatment and prevention (subcutaneous-fascia anchor sutures of donor site, application of corticosteroids by injection into donor site postoperatively, passive drainage can reduce seroma formation and thus overall complication rates, leading to much faster patient’s recovery time and return to normal daily activities.

  5. Characterization of surface topography and chemical composition of mini-implants

    OpenAIRE

    Knop, Luegya Amorim Henriques; Soares, Ana Prates; Shintcovsk, Ricardo Lima; Martins, Lidia Parsekian; Gandini Jr., Luiz Gonzaga

    2015-01-01

    Abstract Aim : To assess the surface topography and chemical composition of three brands of as-received mini-implants (SIN(r), Morelli(r), and Conexao(r)). Methods: Twelve mini-implants of each brand were analyzed by scanning electron microscopy and energy dispersive X-ray (EDX). Results: There was no significant differences among SIN(r), Morelli(r), and Conexao(r) mini-implants comparing their surface topography by visualization of SEM micrographs and analysis of scores. The EDX analysis ...

  6. Late time CMB anisotropies constrain mini-charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Burrage, C.; Redondo, J.; Ringwald, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Jaeckel, J. [Univ. of Durham, Inst. for Particle Physics Phenomenology (United Kingdom)

    2009-09-15

    Observations of the temperature anisotropies induced as light from the CMB passes through large scale structures in the late universe are a sensitive probe of the interactions of photons in such environments. In extensions of the Standard Model which give rise to mini-charged particles, photons propagating through transverse magnetic fields can be lost to pair production of such particles. Such a decrement in the photon flux would occur as photons from the CMB traverse the magnetic fields of galaxy clusters. Therefore late time CMB anisotropies can be used to constrain the properties of mini- charged particles. We outline how this test is constructed, and present new constraints on mini-charged particles from observations of the Sunyaev-Zel'dovich effect in the Coma cluster. (orig.)

  7. A distinct species, Dodona formosana, detected in the Dodona eugenes species complex: clarification of the taxonomic status of the Punch butterfly in Taiwan

    Science.gov (United States)

    Wu, Li-Wei; Lin, Wen-Jie; Hsu, Yu-Feng

    2018-01-01

    Abstract The Tailed Punch, Dodona eugenes, is widely distributed in East Asia with seven subspecies currently recognized. However, two of them, namely ssp. formosana and ssp. esakii found in Taiwan, are hard to distinguish from each other due to ambiguous diagnostic characters. In this study, their taxonomic status is clarified by comparing genitalia characters and phylogenetic relationships based on mitochondrial sequences, COI and COII (total 2211 bps). Our results show that there is no reliable feature to separate these two subspecies. Surprisingly we found that Dodona in Taiwan is more closely related to the Orange Punch, D. egeon, than to other subspecies of D. eugenes. Therefore, the following nomenclatural changes are proposed: Dodona eugenes formosana is revised to specific status as Dodona formosana Matsumura, 1919, stat. rev, and ssp. esakii is sunk to a junior synonym of Dodona formosana syn. n. PMID:29674868

  8. A distinct species, Dodona formosana, detected in the Dodona eugenes species complex: clarification of the taxonomic status of the Punch butterfly in Taiwan

    Directory of Open Access Journals (Sweden)

    Li-Wei Wu

    2018-02-01

    Full Text Available The Tailed Punch, Dodona eugenes, is widely distributed in East Asia with seven subspecies currently recognized. However, two of them, namely ssp. formosana and ssp. esakii found in Taiwan, are hard to distinguish from each other due to ambiguous diagnostic characters. In this study, their taxonomic status is clarified by comparing genitalia characters and phylogenetic relationships based on mitochondrial sequences, COI and COII (total 2211 bps. Our results show that there is no reliable feature to separate these two subspecies. Surprisingly we found that Dodona in Taiwan is more closely related to the Orange Punch, D. egeon, than to other subspecies of D. eugenes. Therefore, the following nomenclatural changes are proposed: Dodona eugenes formosana is revised to specific status as Dodona formosana Matsumura, 1919, stat. rev, and ssp. esakii is sunk to a junior synonym of Dodona formosana syn. n.

  9. Kinematics of self-initiated and reactive karate punches.

    Science.gov (United States)

    Martinez de Quel, Oscar; Bennett, Simon J

    2014-03-01

    This study investigated whether within-task expertise affects the reported asymmetry in execution time exhibited in reactive and self-initiated movements. Karate practitioners and no-karate practitioners were compared performing a reverse punch in reaction to an external stimulus or following the intention to produce a response (self-initiated). The task was completed following the presentation of a specific (i.e., life-size image of opponent) or general stimulus and in the presence of click trains or white noise. Kinematic analyses indicated reactive movement had shorter time to peak velocity and movement time, as well as greater accuracy than self-initiated movement. These differences were independent of participant skill level although peak velocity was higher in the karate practice group than in the no-karate practice group. Reaction time (RT) of skilled participants was facilitated by a specific stimulus. There was no effect on RT or kinematic variables of the different type of auditory cues. The results of this study indicate that asymmetry in execution time of reactive and self-initiated movement holds irrespective of within-task expertise and stimulus specificity. This could have implications for training of sports and/or relearning of tasks that require rapid and accurate movements to intercept/contact a target.

  10. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  11. Autologous mesenchymal stem cells: clinical applications in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Mazzini, Letizia; Mareschi, Katia; Ferrero, Ivana; Vassallo, Elena; Oliveri, Giuseppe; Boccaletti, Riccardo; Testa, Lucia; Livigni, Sergio; Fagioli, Franca

    2006-07-01

    Our study was aimed to evaluate the feasibility and safety of intraspinal cord implantation of autologous mesenchymal stem cells (MSCs) in a few well-monitored amyotrophic lateral sclerosis (ALS) patients. Seven patients affected by definite ALS were enrolled in the study and two patients were treated for compassionate use and monitored for at least 3 years. Bone marrow was collected from the posterior iliac crest according to the standard procedure and MSCs were expanded ex vivo according to Pittenger's protocol. The cells were suspended in 2 ml autologous cerebrospinal fluid and transplanted into the spinal cord by a micrometric pump injector. The in vitro expanded MSCs did not show any bacterial o fungal contamination, hemopoietic cell contamination, chromosomic alterations and early cellular senescence. No patient manifested major adverse events such as respiratory failure or death. Minor adverse events were intercostal pain irradiation and leg sensory dysesthesia, both reversible after a mean period of 6 weeks. No modification of the spinal cord volume or other signs of abnormal cell proliferation were observed. A significant slowing down of the linear decline of the forced vital capacity was evident in four patients 36 months after MSCs transplantation. Our results demonstrate that direct injection of autologous expanded MSCs into the spinal cord of ALS patients is safe, with no significant acute or late toxicity, and well tolerated. The clinical results seem to be encouraging.

  12. Mini-Grids for the Base of the Pyramid Market: A Critical Review

    Directory of Open Access Journals (Sweden)

    Subhes C. Bhattacharyya

    2018-04-01

    Full Text Available The lack of access to electricity of more than 1.1 billion people around the world remains a major developmental challenge and Goal 7 of the Sustainable Development Goals (SDG as well as Sustainable Energy for All (SE4ALL have set a target of universal electrification by 2030. Various studies have identified mini-grid-based electrification as a possible solution. There is a growing body of literature available now that has explored the feasibility, practical application and policy interventions required to support mini-grids. Through a review of available literature, this paper explores whether mini-grids can be a solution for the base of the pyramid (BoP market and the challenges faced in deploying mini-grids in such markets. Interventions to support the mini-grid deployment are also discussed. The paper finds that the mini-grids are targeting the BoP market but the business is not attractive in profitability terms and requires financial support. Lack of regulatory clarity and non-coordinated policies affect the financial viability of projects, which requires careful support. Mini-grid electrification has hardly been embedded in rural development agenda and hence they have not contributed significantly to livelihood generation. Careful realignment of policies, regulatory frameworks and support systems can better support mini-grid deployment in developing countries.

  13. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics.

    Science.gov (United States)

    El-Say, Khalid M; Ahmed, Tarek A; Abdelbary, Maged F; Ali, Bahaa E; Aljaeid, Bader M; Zidan, Ahmed S

    2015-12-01

    This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets) as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1), swelling pressure of the superdisintegrant (X2), and the surface area of Aerosil as a glidant (X3). Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for pre- and post-compression characteristics. The prepared OD-mini-tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2) and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  14. Accelerated Tooth Movement with Orthodontic Mini-Screws

    Directory of Open Access Journals (Sweden)

    S. Aksakalli

    2017-01-01

    Full Text Available This case report outlines the possibility of accelerated tooth movement with the combination of microosteoperforation and mini-screws. A 14-year-old male patient presented Class II malocclusion with maxillary incisor protrusion. Upper first premolars were extracted, and after leveling, accelerated canine distalization started. For pre- and postdistalization times, amount of distalization, periodontal health, and root resorption were assessed. Within the limitations of this case report, micro-osteoperforations with mini-screw have a potential for shortening the treatment time.

  15. Predicting everyday functional abilities of dementia patients with the Mini-Mental State Examination.

    Science.gov (United States)

    Razani, Jill; Wong, Jennifer T; Dafaeeboini, Natalia; Edwards-Lee, Terri; Lu, Po; Alessi, Cathy; Josephson, Karen

    2009-03-01

    The Mini-Mental State Examination is a widely used cognitive screening measure. The purpose of the present study was to assess how 5 specific clusters of Mini-Mental State Examination items (ie, subscores) correlate with and predict specific areas of daily functioning in dementia patients, 61 patients with varied forms of dementia were administered the Mini-Mental State Examination and an observation-based daily functional test (the Direct Assessment of Functional Status). The results revealed that the orientation and attention subscores of the Mini-Mental State Examination correlated most significantly with most functional domains. The Mini-Mental State Examination language items correlated with all but the shopping and time orientation tasks, while the Mini-Mental State Examination recall items correlated with the Direct Assessment of Functional Status time orientation and shopping tasks. Stepwise regression analyses found that among the Mini-Mental State Examination subscores, orientation was the single, best independent predictor of daily functioning.

  16. Autologous Bone Marrow Stem Cell Infusion (AMBI therapy for Chronic Liver Diseases

    Directory of Open Access Journals (Sweden)

    Rajkumar JS

    2007-01-01

    Full Text Available Liver Cirrhosis is the end stage of chronic liver disease which may happen due to alcoholism, viral infections due to Hepatitis B, Hepatitis C viruses and is difficult to treat. Liver transplantation is the only available definitive treatment which is marred by lack of donors, post operative complications such as rejection and high cost. Autologous bone marrow stem cells have shown a lot of promise in earlier reported animal studies and clinical trials. We have in this study administered in 22 patients with chronic liver disease, autologous bone marrow stem cell whose results are presented herewith.

  17. Validity of a short clinical interview for psychiatric diagnosis: the mini-SCAN.

    Science.gov (United States)

    Nienhuis, F J; van de Willige, G; Rijnders, C A Th; de Jonge, P; Wiersma, D

    2010-01-01

    To promote clinical application of the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) system a shorter version (the mini-SCAN) was devised. Its psychometric properties were unknown. To establish the validity and practical properties of the mini-SCAN. One hundred and six participants were interviewed twice, once with the SCAN and once with the mini-SCAN. The level of agreement was established for the categories: no disorder, affective disorders, anxiety disorders, non-affective psychotic disorders, affective psychotic disorders. The mini-SCAN is a valid instrument. Most kappa values were around 0.90. Only for the class of affective psychotic disorders was the agreement moderate. Mean duration of the mini-SCAN interviews was 25 min shorter than the SCAN interviews. Participants and interviewers were generally satisfied with the interview format and questions. The mini-SCAN can be used as a diagnostic instrument for clinical purposes and for clinical studies when the present episode is the focus of attention.

  18. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  19. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  20. Pulmonary heart valve replacement using stabilized acellular xenogeneic scaffolds; effects of seeding with autologous stem cells

    Directory of Open Access Journals (Sweden)

    Harpa Marius Mihai

    2015-12-01

    Full Text Available Background: We hypothesized that an ideal heart valve replacement would be acellular valve root scaffolds seeded with autologous stem cells. To test this hypothesis, we prepared porcine acellular pulmonary valves, seeded them with autologous adipose derived stem cells (ADSCs and implanted them in sheep and compared them to acellular valves.

  1. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  2. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  3. Delphi report 1995 on developments in science and technology. Mini Delphi; Delphi-Bericht 1995 zur Entwicklung von Wissenschaft und Technik. Mini-Delphi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    In August 1993 the first German `Delphi Report on Developments in Science and Technology` was published. It was elaborated by the Fraunhofer Institute for System Engineering and Innovation Research (FhG-ISI) in cooperation with the Japanese National Institute of Science and Technology Policy (NISTEP). The `MINI-DELPHI` now completed by FhG-ISI, again in cooperation with NISTEP, is a further development of the Delphi approach in that it is more differentiated in its questions and assessment criteria than its predecessors. `MINI-DELPHI` is not intended as a comprehensive forecast on technology in general but rather focusses on key topics. Its emphasis is on technology demand and the relevance of technologies to social issues. Although the Mini-Delphi study was primarily aimed at further refining the methodology employed, it nevertheless contains a wealth of information and details on circumscript questions. The requisite database is provided by tables on the results of two inquiry rounds among Japanese and German experts. (orig./RHM) [Deutsch] Im August 1993 wurde der erste deutsche `Delphi-Bericht zur Entwicklung von Wissenschaft und Technik` veroeffentlicht. Er war vom Fraunhofer-Institut fuer Systemtechnik und Innovationsforschung (FhG-ISI) in Zusammenarbeit mit dem japanischen National Institute of Science and Technology Policy (NISTEP) erarbeitet worden. Mit dem jetzt vorliegenden `MINI-DELPHI` hat das FhG-ISI - wieder in Zusammenarbeit mit dem NISTEP - den Delphi-Ansatz fortentwickelt und sowohl hinsichtlich der Fragen als auch der Beurteilungskriterien weiter ausdifferenziert. `MINI-DELPHI` bezweckt keine umfassende Technologievorausschau, sondern konzentriert sich auf Schluesselthemen. Im Vordergrund steht der Gedanke des Technikbedarfs und die Relevanz fuer gesellschaftliche Fragestellungen. Obwohl die Mini-Delphi-Studie vorrangig der Weiterentwicklung der Methodik dient, enthaelt sich eine Fuelle von Informationen und Details zu Einzelfragen. Die im Bericht

  4. Designing a mini subcritical nuclear reactor

    International Nuclear Information System (INIS)

    Escobedo G, C. R.; Vega C, H. R.; Davila H, V. M.

    2015-10-01

    In this work the design of a mini subcritical nuclear reactor formed by means of light water moderator, uranium as fuel, and isotopic neutron source of 239 PuBe was carried out. The design was done by Monte Carlo methods with the code MCNP5 in which uranium was modeled in an array of concentric holes cylinders of 8.5, 14.5, 20.5, 26.5, 32.5 cm of internal radius and 3 cm of thickness, 36 cm of height. Different models were made from a single fuel cylinder (natural uranium) to five. The neutron source of 239 PuBe was situated in the center of the mini reactor; in each arrangement was used water as moderator. Cross sections libraries Endf/Vi were used and the number of stories was large enough to ensure less uncertainty than 3%. For each case the effective multiplication factor k e -f f , the amplification factor and the power was calculated. Outside the mini reactor the ambient dose equivalent H (10) was calculated for different cases. The value of k eff , the amplification factor and power are directly related to the number of cylinders of uranium as fuel. Although the average energy of the neutrons 239 PuBe is between 4.5 and 5 MeV in the case of the mini reactor for a cylinder, in the neutron spectrum the presence of thermal neutrons does not exist, so that produced fissions are generated with fast neutrons, and in designs of two and three rings the neutron spectra shows the presence of thermal neutrons, however the fissions are being generated with fast neutrons. Finally in the four and five cases the amount of moderator is enough to thermalized the neutrons and thereby produce the fission. The maximum value for k eff was 0.82; this value is very close to the assembly of Universidad Autonoma de Zacatecas generating a k eff of 0.86. According to the safety and radiation protection standards for the design of mini reactor of one, two and three cylinders they comply with the established safety, while designs of four and five cylinders not met. (Author)

  5. Unicameral bone cysts: a comparison of injection of steroid and grafting with autologous bone marrow.

    Science.gov (United States)

    Cho, H S; Oh, J H; Kim, H-S; Kang, H G; Lee, S H

    2007-02-01

    Open surgery is rarely justified for the initial treatment of a unicameral bone cyst, but there is some debate concerning the relative effectiveness of closed methods. This study compared the results of steroid injection with those of autologous bone marrow grafting for the treatment of unicameral bone cysts. Between 1990 and 2001, 30 patients were treated by steroid injection and 28 by grafting with autologous bone marrow. The overall success rates were 86.7% and 92.0%, respectively (p>0.05). The success rate after the initial procedure was 23.3% in the steroid group and 52.0% in those receiving autologous bone marrow (p0.05). The mean number of procedures required was 2.19 (1 to 5) and 1.57 (1 to 3) (p0.05), and the rate of recurrence after the initial procedure was 41.7% and 13.3% in the steroid and in the autologous bone marrow groups, respectively (p<0.05). Although the overall rates of success of both methods were similar, the steroid group had higher recurrence after a single procedure and required more injections to achieve healing.

  6. Scintigraphic detection of carotid atherosclerosis with indium-111-labeled autologous platelets

    International Nuclear Information System (INIS)

    Davis, H.H.; Siegel, B.A.; Sherman, L.A.; Heaton, W.A.; Naidich, T.P.; Joist, J.R.; Welch, M.J.

    1980-01-01

    Using autologous platelets labeled with indium-111-oxine, we studied the localization of platelets on arterial lesions by radionuclide scintigraphy in 34 patients with suspected cerebrovascular disease. The imaging results were compared with the findings of contrast angiography in 23 patients, 16 of whom were receiving antiplatelet and/or anticoagulant drugs during the platelet imaging study. Angiography demonstrated atherosclerotic lesions at 33 sites in the extracranial arteries of 16 of these patients. There was accumulation of 111 In-platelets at 20 of these sites (61%) and at three other sites without definite angiographic abnormalities. Lesions with stenoses 111 In-labeled autologous platelets may be useful for evaluating the pathophysiologic characteristics of atherosclerotic lesions in patients with cerebrovascular disease

  7. Internal Structure of Mini-CEX Scores for Internal Medicine Residents: Factor Analysis and Generalizability

    Science.gov (United States)

    Cook, David A.; Beckman, Thomas J.; Mandrekar, Jayawant N.; Pankratz, V. Shane

    2010-01-01

    The mini-CEX is widely used to rate directly observed resident-patient encounters. Although several studies have explored the reliability of mini-CEX scores, the dimensionality of mini-CEX scores is incompletely understood. Objective: Explore the dimensionality of mini-CEX scores through factor analysis and generalizability analysis. Design:…

  8. Oral mucosa: an alternative epidermic cell source to develop autologous dermal-epidermal substitutes from diabetic subjects

    Directory of Open Access Journals (Sweden)

    Daniela GUZMÁN-URIBE

    Full Text Available Abstract Oral mucosa has been highlighted as a suitable source of epidermal cells due to its intrinsic characteristics such as its higher proliferation rate and its obtainability. Diabetic ulcers have a worldwide prevalence that is variable (1%-11%, meanwhile treatment of this has been proven ineffective. Tissue-engineered skin plays an important role in wound care focusing on strategies such autologous dermal-epidermal substitutes. Objective The aim of this study was to obtain autologous dermal-epidermal skin substitutes from oral mucosa from diabetic subjects as a first step towards a possible clinical application for cases of diabetic foot. Material and Methods Oral mucosa was obtained from diabetic and healthy subjects (n=20 per group. Epidermal cells were isolated and cultured using autologous fibrin to develop dermal-epidermal in vitro substitutes by the air-liquid technique with autologous human serum as a supplement media. Substitutes were immunocharacterized with collagen IV and cytokeratin 5-14 as specific markers. A Student´s t- test was performed to assess the differences between both groups. Results It was possible to isolate epidermal cells from the oral mucosa of diabetic and healthy subjects and develop autologous dermal-epidermal skin substitutes using autologous serum as a supplement. Differences in the expression of specific markers were observed and the cytokeratin 5-14 expression was lower in the diabetic substitutes, and the collagen IV expression was higher in the diabetic substitutes when compared with the healthy group, showing a significant difference. Conclusion Cells from oral mucosa could be an alternative and less invasive source for skin substitutes and wound healing. A difference in collagen production of diabetic cells suggests diabetic substitutes could improve diabetic wound healing. More research is needed to determine the crosstalk between components of these skin substitutes and damaged tissues.

  9. Mini-Digest of Education Statistics, 2008. NCES 2009-021

    Science.gov (United States)

    Snyder, Thomas D.

    2009-01-01

    This publication is the 14th edition of the "Mini-Digest of Education Statistics," a pocket-sized compilation of statistical information covering the broad field of American education from kindergarten through graduate school. The "Mini-Digest" is designed as an easy reference for materials found in much greater detail in the…

  10. Fibrous mini-collagens in hydra nematocysts.

    Science.gov (United States)

    Holstein, T W; Benoit, M; Herder, G V; David, C N; Wanner, G; Gaub, H E

    1994-07-15

    Nematocysts (cnidocysts) are exocytotic organelles found in all cnidarians. Here, atomic force microscopy and field emission scanning electron microscopy reveal the structure of the nematocyst capsule wall. The outer wall consists of globular proteins of unknown function. The inner wall consists of bundles of collagen-like fibrils having a spacing of 50 to 100 nanometers and cross-striations at intervals of 32 nanometers. The fibrils consist of polymers of "mini-collagens," which are abundant in the nematocysts of Hydra. The distinct pattern of mini-collagen fibers in the inner wall can provide the tensile strength necessary to withstand the high osmotic pressure (15 megapascals) in the capsules.

  11. Concerning production and decay of mini black holes

    CERN Document Server

    Hajdukovic, D

    2007-01-01

    In the next few years, theories predicting possibility to create mini black holes will be tested at CERN. Either experimental verification or rejection of these theories is of great scientific importance. There is a large consensus that, if successfully created, these short living mini black holes will decay through thermal (Hawking's) radiation. In the present comment we point out, that under assumption of the gravitational repulsion between matter and antimatter (in short we call it antigravity), thermal radiation may be dominated by a non-thermal radiation (being the consequence of pair creation from the vacuum, by gravitational field, which in the case of antigravity, pushes particles and antiparticles in opposite directions). Thus, the eventual creation of mini black holes may turn to be an unexpected opportunity to test the existence of antigravity.

  12. Replacing a failed mini-implant with a miniplate to prevent interruption during orthodontic treatment.

    Science.gov (United States)

    Lee, Jin-Hwa; Choo, Hyeran; Kim, Seong-Hun; Chung, Kyu-Rhim; Giannuzzi, Lucille A; Ngan, Peter

    2011-06-01

    When mini-implants fail during orthodontic treatment, there is a need to have a backup plan to either replace the failed implant in the adjacent interradicular area or wait for the bone to heal before replacing the mini-implant. We propose a novel way to overcome this problem by replacement with a miniplate so as not to interrupt treatment or prolong treatment time. The indications, advantages, efficacy, and procedures for switching from a mini-implant to a miniplate are discussed. Two patients who required replacement of failed mini-implants are presented. In the first patient, because of the proximity of the buccal vestibule to the mini-implant, it was decided to replace the failed mini-implant by an I-shaped C-tube miniplate. In the second patient, radiolucencies were found around the failed mini-implants, making the adjacent alveolar bone unavailable for immediate placement of another mini-implant. In addition, the maxillary sinus pneumatization was expanded deeply into the interradicular spaces; this further mandated an alternative placement site. One failed mini-implant was examined under a scanning electron microscope for bone attachment. Treatment was completed in both patients after replacement with miniplates without interrupting the treatment mechanics or prolonging the treatments. Examination under the scanning electron microscope showed partial bone growth into the coating pores and titanium substrate interface even after thorough cleaning and sterilization. Replacement with a miniplate is a viable solution for failed mini-implants during orthodontic treatment. The results from microscopic evaluation of the failed mini-implant suggest that stringent guidelines are needed for recycling used mini-implants. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  13. Evidences of autologous fat grafting for the treatment of keloids and hypertrophic scars

    Directory of Open Access Journals (Sweden)

    VINÍCIUS ZOLEZI DA SILVA

    Full Text Available SUMMARY Introduction Since the 1980s, the use of autologous fat grafting has been growing in plastic surgery. Recently, this procedure has come to be used as a treatment for keloids and hypertrophic scars mainly due to the lack of satisfactory results with other techniques. So far, however, it lacks more consistent scientific evidence to recommend its use. The aim of this study was to review the current state of autologous fat grafting for the treatment of keloids and hypertrophic scars, their benefits and scientific evidences in the literature. Method A review in the Pubmed database was performed using the keywords “fat grafting and scar”, “fat grafting and keloid scar” and “fat grafting and hypertrophic scar.” Inclusion criteria were articles written in English and published in the last 10 years, resulting in 15 studies. Results These articles indicate that autologous fat grafting carried out at sites with pathological scars leads to a reduction of the fibrosis and pain, an increased range of movement in areas of scar contraction, an increase in their flexibility, resulting in a better quality of scars. Conclusion So far, evidences suggest that autologous fat grafting for the treatment of keloids and hypertrophic scars is associated with a better quality of scars, leading to esthetic and functional benefits. However, this review has limitations and these findings should be treated with reservations, since they mostly came from studies with low levels of evidence.

  14. Evaluation of mini super computers for nuclear design applications

    International Nuclear Information System (INIS)

    Altomare, S.; Baradari, F.

    1987-01-01

    The evolution of the mini super computers will force changes from the current environment of performing nuclear design calculations on mainframe computers (such as a CRAY) to mini super computers. This change will come about for a number of reasons. First, the mini super computers currently available in the marketplace offer the power and speed comparable to mainframes and can provide the capability to support highly computer intensive calculations. Second, the equipment is physically smaller and can easily be installed and operated without extensive investments in facilities and operations support. Third, the computer capacity can be acquired with as much needed memory, disk, and tape capacity as may be needed. Another reasons is that the performance/cost ratio has increased drastically as hardware costs have decreased. A study was conducted at the Westinghouse Commercial Nuclear Fuel Division (CNFD) to evaluate the mini super computers for use in nuclear core design. As a result of this evaluation, Westinghouse CNFD is offering a combined hardware/software technology transfer package for core design. This package provides the utility designer with a totally dedicated mini super computer comparable in speed to the CRAY 1S with sufficient capacity for a sizable design group to perform the engineering activities related to nuclear core design and operations support. This also assures the utility of being totally compatible with the CNFD design codes, thus assuring total update compatibility

  15. Study of the mechanical properties of the electric power station components: the punch test; Etude des proprietes mecaniques des composants de centrales thermiques: l'essai punch test

    Energy Technology Data Exchange (ETDEWEB)

    Isselin, J

    2003-03-15

    The aging of the electric production park implies an increasing need of knowledge concerning the evolution of the mechanical properties of its components. With regard to this problem, the availability in material is more and more small. This work proposes to characterize these properties through a mechanical test called Punch test. The main characteristic of this test is to use very small volume samples. The development of this test has been carried out by the study of a 15 MDV 4-05 steel coming from a steam drum of a thermal power plant after 145000 hours of service. At first, we have measured the influence of the parameters of this test. Then, the study has dealt more particularly on the transition temperature of the material. With the finite element simulation method, the strain hardening coefficient of the material has been determined. (O.M.)

  16. Mini-clinical evaluation exercise til evaluering af kommunikation og samarbejde i ambulatoriet

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Simonsen, Dorit; Bastholt, Lars

    2009-01-01

    INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation of communi......INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation...

  17. Analytical and experimental investigation of the elastic and plastic behavior of plates on foundations subjected to dynamic punch loading

    International Nuclear Information System (INIS)

    Duffey, T.A.; Sutherland, S.H.; Cheresh, M.

    1980-01-01

    Analytical solutions and experimental results are presented for the response of foundation-backed plates to static and dynamic punch loading. Tests were performed on polyurethane foam-backed and unbacked plates; plates were centrally loaded over a range-in plastic deformations up to complete failure. This is part of an attempt to understand the puncture resistance of the sidewalls of containers used to ship hazardous wastes

  18. Injuries in Japanese Mini-Basketball Players During Practices and Games

    Science.gov (United States)

    Kuzuhara, Kenji; Shibata, Masashi; Uchida, Ryo

    2016-01-01

    Context: Mini-basketball is one of the most popular junior sports in Japan. Mini-basketball–related injuries may increase because of early specialization. However, no reports have been published to date concerning basketball injuries in children younger than 12 years of age. Objective: To prospectively study the incidence, sites, types, and mechanisms of injuries in mini-basketball teams. Design: Descriptive epidemiology study. Setting: Mini-basketball teams in Kobe, Japan. Patients or Other Participants: A total of 95 players in 7 community-based mini-basketball club teams (age range, 9 through 12 years). Main Outcome Measure(s): Data on all practice and game injuries for the 2013–2014 season were collected using an injury report form. Injury rates were calculated according to site, type, and mechanism. Results: The overall injury rate was 3.83 per 1000 athlete-hours (AHs). The game injury rate (12.92/1000 AHs) was higher than the practice injury rate (3.13/1000 AHs; P basketball players. The high practice injury rate in this study may be due to specific factors related to growth, such as individual differences in height, or to skills, such as inexperience in ball handling. PMID:27922287

  19. Gender and Self-Employment: The Role of Mini-Companies

    Science.gov (United States)

    Johansen, Vegard

    2016-01-01

    Purpose: The purpose of this paper is to evaluate to what degree participation in mini-companies impact young women and men with regard to the perceived desirability and perceived feasibility of self-employment. The Company Programme (CP) is the largest mini-company scheme in European secondary school. Design/methodology/approach: The data derived…

  20. Afrique : ressources minières, environnement et gouvernance ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    25 janv. 2011 ... ils regorgent de richesses inouïes », assure Bonnie Campbell, directrice du Groupe de recherche sur les activités minières en Afrique (GRAMA) et titulaire de la Chaire C.-A. Poissant de recherche sur la gouvernance et l'aide au développement, faisant référence aux ressources minières et pétrolières dont ...

  1. MiniDLNA_tweaker : Aplicació per configurar i previsualitzar el servidor MiniDLNA per a GNU/Linux

    OpenAIRE

    Martínez Lloveras, Jordi

    2013-01-01

    L'aplicació MiniDLNA per a GNU/Linux és un servidor lleuger que compleix els estàndards DLNA/UPnP configurable a través d'un simple arxiu de text, això la fa ideal per al propòsit d'implantació d'un servidor que ofereixi els continguts a tots els dispositius que compleixin els estàndards esmentats. La aplicación MiniDLNA para GNU/Linux es un servidor ligero que cumple los estándares DLNA/UPnP configurable a través de un simple archivo de texto, esto la hace ideal para el propósito de impla...

  2. Feasibility of pre-operative autologous blood donation in Indian patients with elective orthopaedic surgery.

    Science.gov (United States)

    Saluja, Karan; Marwaha, Neelam; Thakral, Beenu; Goni, Vijay; Sharma, R R; Puri, G D

    2006-11-01

    Pre-operative autologous blood donation (PABD) in elective orthopaedic surgeries is a well known procedure in the West. We initiated this programme at a tertiary care hospital in north India to study its feasibility in Indian patients. In a prospective case-control study, 144 patients undergoing primary total hip or knee replacement, inter-vertebral discectomy, mal-union and non-union reconstruction were educated and motivated to pre-donate. Patients fulfilling the inclusion criteria and making autologous donation formed the PABD group (n=22). Patients eligible for PABD, but unwilling to participate; age, sex, pre-operative haemoglobin and operative procedure matched acted as controls (n=27). Unit(s) collected was processed like an allogeneic unit. Unit(s) found reactive for infectious markers or not utilized was discarded. Mean blood losses, transfusion trigger, allogeneic exposure and wastage between the two groups were compared. Of the 144 patients motivated, 40 per cent of the eligible subjects pre-deposited. The main motivational factor was fear of getting infection from someone's blood. Cardiac events and anaemia prevented 61.8 per cent patients to participate. Of the 50 units ordered, autologous units with a mean of 1.4 units/patient contributed 62 per cent. For total hip and total knee replacement (THR and TKR), autologous units met 76.2 and 80 per cent respectively of the total blood requirement. A significant decrease in the allogeneic exposure was observed between PABD and control group (18.2 vs 66.7%); 32.3 per cent of the autologous units were discarded. Comprehensive PABD programme may be an effective method for reducing the need for allogeneic transfusion in patients undergoing joint replacement surgeries in our country, where transfusion transmitted infections due to high percentage of replacement donations and lack of sensitive assays for testing are still a cause for concern.

  3. Impact of Postoperative Antibiotic Prophylaxis Duration on Surgical Site Infections in Autologous Breast Reconstruction.

    Science.gov (United States)

    Drury, Kerry E; Lanier, Steven T; Khavanin, Nima; Hume, Keith M; Gutowski, Karol A; Thornton, Brian P; Hansen, Nora M; Murphy, Robert X; Fine, Neil A; Kim, John Y S

    2016-02-01

    Although some surgeons prescribe prolonged postoperative antibiotics after autologous breast reconstruction, evidence is lacking to support this practice. We used the Tracking Operations and Outcomes for Plastic Surgeons database to evaluate the association between postoperative antibiotic duration and the rate of surgical site infection (SSI) in autologous breast reconstruction. The intervention of interest for this study was postoperative duration of antibiotic prophylaxis: either discontinued 24 hours after surgery or continued beyond 24 hours. The primary outcome variable of interest for this study was the presence of SSI within 30 days of autologous breast reconstruction. Cohort characteristics and 30-day outcomes were compared using χ² and Fischer exact tests for categorical variables and Student t tests for continuous variables. Multivariate logistic regression was used to control for confounders. A total of 1036 patients met inclusion criteria for our study. Six hundred fifty-nine patients (63.6%) received antibiotics for 24 hours postoperatively, and 377 patients (36.4%) received antibiotics for greater than 24 hours. The rate of SSI did not differ significantly between patients given antibiotics for only 24 hours and those continued on antibiotics beyond the 24-hour postoperative time period (5.01% vs 2.92%, P = 0.109). Furthermore, antibiotic duration was not predictive of SSI in multivariate regression modeling. We did not find a statistically significant difference in the rate of SSI in patients who received 24 hours of postoperative antibiotics compared to those that received antibiotics for greater than 24 hours. These findings held for both purely autologous reconstruction as well as latissimus dorsi reconstruction in conjunction with an implant. Thus, our study does not support continuation of postoperative antibiotics beyond 24 hours after autologous breast reconstruction.

  4. Agreement between clinical and MINI diagnoses in outpatients with mood and anxiety disorders

    NARCIS (Netherlands)

    Verhoeven, F. E. A.; Swaab, L. S. M. A.; Carlier, I. V. E.; van Hemert, A. M.; Zitman, F. G.; Ruhé, H. G.; Schoevers, R. A.; Giltay, E. J.

    2017-01-01

    Background: Standardized Diagnostic Interviews (SDIs) such as the Mini International Neuropsychiatric Interview (MINI) are widely used to systematically screen for psychiatric disorders in research. To support generalizability of results to clinical practice, we assessed agreement between the MINI

  5. Do dual-thread orthodontic mini-implants improve bone/tissue mechanical retention?

    Science.gov (United States)

    Lin, Yang-Sung; Chang, Yau-Zen; Yu, Jian-Hong; Lin, Chun-Li

    2014-12-01

    The aim of this study was to understand whether the pitch relationship between micro and macro thread designs with a parametrical relationship in a dual-thread mini-implant can improve primary stability. Three types of mini-implants consisting of single-thread (ST) (0.75 mm pitch in whole length), dual-thread A (DTA) with double-start 0.375 mm pitch, and dual-thread B (DTB) with single-start 0.2 mm pitch in upper 2-mm micro thread region for performing insertion and pull-out testing. Histomorphometric analysis was performed in these specimens in evaluating peri-implant bone defects using a non-contact vision measuring system. The maximum inserted torque (Tmax) in type DTA was found to be the smallest significantly, but corresponding values found no significant difference between ST and DTB. The largest pull-out strength (Fmax) in the DTA mini-implant was found significantly greater than that for the ST mini-implant regardless of implant insertion orientation. Mini-implant engaged the cortical bone well as observed in ST and DTA types. Dual-thread mini-implant with correct micro thread pitch (parametrical relationship with macro thread pitch) in the cortical bone region can improve primary stability and enhanced mechanical retention.

  6. Autologous Chondrocyte Implantation in Osteoarthritic Surroundings

    DEFF Research Database (Denmark)

    Ossendorff, Robert; Grad, Sibylle; Stoddart, Martin J

    2018-01-01

    BACKGROUND: Autologous chondrocyte implantation (ACI) fails in up to 20% of cases. Advanced intra-articular degeneration paired with an inflammatory environment may be closely related to implantation failure. Certain cytokines have been identified to play a major role during early osteoarthritis....... PURPOSE: To investigate the effects of tumor necrosis factor α (TNFα) and its potential inhibition by adalimumab on cartilage regeneration in an in vitro model of ACI. STUDY DESIGN: Controlled laboratory study. METHODS: Bovine articular chondrocytes were cultivated and transferred at passage 3 to fibrin...

  7. The Galactic Centre Mini-Spiral with CARMA

    Science.gov (United States)

    Kunneriath, D.; Eckart, A.; Vogel, S. N.; Teuben, P.; Muzic, K.; Schodel. R.; Garcia-Marin, M.; Moultaka, J.; Staguhn, J.; Straubmeier, C.; hide

    2012-01-01

    The Galactic centre mini-spiral region is a mixture of gas and dust with temperatures ranging from a few hundred K to 10(exp 4) K. We report results from 1.3 and 3mm radio interferometric observations of this region with CARMA, and present a spectral index map of this region. We find a range of emission mechanisms in the region, including the inverted synchrotron spectrum of Sgr A*, free-free emission from the mini-spiral arms, and a possible dust emission contribution indicated by a positive spectral index.

  8. Photovoltaic energy mini-generation: Future perspectives for Portugal

    International Nuclear Information System (INIS)

    Carvalho, Duarte; Wemans, Joao; Lima, Joao; Malico, Isabel

    2011-01-01

    This paper evaluates the benefits of developing the mini-generation PV market in Portugal. It presents the legal framework and current status of the Portuguese PV electricity sector, and compares the country to other European nations: France, Germany, Greece, Italy, Spain and the United Kingdom. A model that combines PVGIS with a self-developed financial tool is used to assess the feasibility of a 150 kW mini-generation system using five different technologies: fixed mount, single-axis tracking, double-axis tracking, low concentration and medium concentration (MCPV). The profitability of the mini-generation systems in the seven countries studied is calculated and compared. According to this analysis, MCPV and, of the conventional technologies, the single-axis tracking systems are the most profitable technologies. Despite the attractiveness of the current Portuguese feed-in tariffs and of the abundant solar resource, investors are discouraged and the country's PV market is far from mature. Specific mini-generation regulations should focus on a fast and transparent licensing procedure and should promote the access to financing. This would attract new investments, which would result in the growth of the PV electricity produced, and would help Portugal to meet its European Union Renewable Energy targets. - Highlights: → This work promotes the development of a mini-generation PV market in Portugal. → The Portuguese current status and legal framework is compared to other EU countries. → The profitability of 5 different PV technologies is compared for 7 European countries. → The Portuguese growth potential for PV energy is still big. → Portugal, due to its radiation levels, presents excellent investment opportunities.

  9. Hyaline cartilage degenerates after autologous osteochondral transplantation.

    Science.gov (United States)

    Tibesku, C O; Szuwart, T; Kleffner, T O; Schlegel, P M; Jahn, U R; Van Aken, H; Fuchs, S

    2004-11-01

    Autologous osteochondral grafting is a well-established clinical procedure to treat focal cartilage defects in patients, although basic research on this topic remains sparse. The aim of the current study was to evaluate (1) histological changes of transplanted hyaline cartilage of osteochondral grafts and (2) the tissue that connects the transplanted cartilage with the adjacent cartilage in a sheep model. Both knee joints of four sheep were opened surgically and osteochondral grafts were harvested and simultaneously transplanted to the contralateral femoral condyle. The animals were sacrificed after three months and the received knee joints were evaluated histologically. Histological evaluation showed a complete ingrowth of the osseous part of the osteochondral grafts. A healing or ingrowth at the level of the cartilage could not be observed. Histological evaluation of the transplanted grafts according to Mankin revealed significantly more and more severe signs of degeneration than the adjacent cartilage, such as cloning of chondrocytes and irregularities of the articular surface. We found no connecting tissue between the transplanted and the adjacent cartilage and histological signs of degeneration of the transplanted hyaline cartilage. In the light of these findings, long-term results of autologous osteochondral grafts in human beings have to be followed critically.

  10. Persistent seropositivity for yellow fever in a previously vaccinated autologous hematopoietic stem cell transplantation recipient.

    Science.gov (United States)

    Hayakawa, Kayoko; Takasaki, Tomohiko; Tsunemine, Hiroko; Kanagawa, Shuzo; Kutsuna, Satoshi; Takeshita, Nozomi; Mawatari, Momoko; Fujiya, Yoshihiro; Yamamoto, Kei; Ohmagari, Norio; Kato, Yasuyuki

    2015-08-01

    The duration of a protective level of yellow fever antibodies after autologous hematopoietic stem cell transplantation in a previously vaccinated person is unclear. The case of a patient who had previously been vaccinated for yellow fever and who remained seropositive for 22 months after autologous peripheral blood stem cell transplantation for malignant lymphoma is described herein. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Autologous Blood and Platelet-Rich Plasma Injections for Treatment of Lateral Epicondylitis.

    Science.gov (United States)

    Calandruccio, James H; Steiner, Murphy M

    2017-07-01

    Lateral epicondylitis (tennis elbow) is a frequent cause of elbow pain; most patients (80%-90%) are successfully treated with standard nonoperative methods (rest, nonsteroidal anti-inflammatory drugs, bracing, and physical therapy). Autologous blood injections and platelet-rich plasma injections are the two most frequently used orthobiologic techniques in the treatment of lateral epicondylitis. Studies of the effectiveness of autologous blood injections and platelet-rich plasma report varying outcomes, some citing significant clinical relief and others reporting no beneficial effect. More research is needed to determine how to best use orthobiologics in the treatment of lateral epicondylitis. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA in a Mexican Population

    Directory of Open Access Journals (Sweden)

    María Fernanda Bernal-Orozco

    2018-04-01

    Full Text Available Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy or 1 (healthy, and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April–August 2016, were invited to participate. The survey was administered in two rounds (test and retest with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC, and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant. The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001, and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885. It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance.

  13. Comparison between sensitivity of autologous skin serum test and autologous plasma skin test in patients with Chronic Idiopathic Urticaria for detection of antibody against IgE or IgE receptor (FcεRIα).

    Science.gov (United States)

    Sajedi, Vahid; Movahedi, Masoud; Aghamohammadi, Asghar; Aghamohamadi, Asghar; Gharagozlou, Mohammad; Ghareguzlou, Mohammad; Shafiei, Alireza; Soheili, Habib; Sanajian, Nahal

    2011-06-01

    Intradermal injection of autologous serum and plasma elicit a cutaneous reactivity in almost 45-60% of patients with Chronic Idiopathic Urticaria (CIU). This reactivity is associated with the presence of auto antibodies against IgE or IgE receptors. This study was carried out to compare the cutaneous reactivity of autologous serum and plasma skin tests in a series of patients with CIU for diagnosis of auto antibodies against IgE or IgE receptor. Fifty eight patients with CIU were injected intradermally with autologous serum and plasma (anticoagulated by citrate). Histamine was used as positive control and normal saline as negative control. The study group was checked by routine laboratory tests (CBC, U/A etc), allergens with skin prick tests, and serum IgE level, and auto antibodies against thyroid as well. Duration of urticaria was another factor which was assessed.There was no significant difference between positive ASST and positive APST patients for the above mentioned tests. 77.6% of the patients were Positive for APST and 65.5% were ASST positive. Duration of urticaria was longer in patients with positive ASST and APST than ASST and APST negative patients, although the difference was not statistically significant.Autologus serum skin test (ASST) and autologous plasma skin test (APST) could be used for estimation of duration and severity of urticaria and planning for the treatment.

  14. Paradigm shifts in orthodontic treatment with mini-implant anchorage

    Directory of Open Access Journals (Sweden)

    Johnny Joung-Lin Liaw

    2015-01-01

    Full Text Available After the applications of mini-implant anchorage, the envelope of orthodontic treatment was expanded and some treatment modes were changed because of more predictable tooth movement with empowered anchorage. The author tried to share his experience of TADs applications for clarifying the paradigm shifts of orthodontic treatment assisted with the mini-implant anchorage.

  15. Mini implants for definitive prosthodontic treatment: a systematic review.

    Science.gov (United States)

    Bidra, Avinash S; Almas, Khalid

    2013-03-01

    Mini implants are commonly used in orthodontics and for interim prosthodontic treatment, but evidence for their use in definitive prosthodontic treatment is not clear. This systematic review evaluated the mini-implant literature to analyze short-term (1 to 5 years), medium-term (5 to 10 years), and long-term (beyond 10 years) survival rates when used for definitive prosthodontic treatment. An electronic search of the English language literature for articles published between January 1974 and May 2012 was performed by using PubMed and Cochrane databases with predetermined inclusion criteria. Key terms included in the search were mini dental implants, narrow diameter implants, reduced diameter implants, small diameter implants, transitional implants, interim implants, and provisional implants. After a systematic filtering process, the selected articles were subjected to a detailed review, and the data collected were used to calculate the 1-year interval survival rate (ISR) and the cumulative survival rate (CSR). The electronic database search yielded 1807 titles. By scrutinizing the titles and abstracts with inclusion and exclusion criteria, the researchers identified 9 studies of mini implants for definitive prosthodontic treatment. Of the studies identified, 1 was a randomized controlled trial, 2 were prospective studies, and 6 were retrospective studies. The majority of mini implants were placed by using a flapless surgical technique in the mandibular anterior region to support an overdenture. The 1st year ISR was 94.7% and the CSR over a 9-year period, primarily attributed to data from 1 study, was 92.2%. Most implants were immediately loaded and almost all implant failures occurred during the first year after implant placement. For short-term survival, the first year ISR of 94.7% of mini dental implants appears encouraging, but the true 1-year survival rate is unknown, as the minimum follow-up period reported for several implants was less than a year

  16. Mini-Sniffer III on Lakebed with Ground Support Crew

    Science.gov (United States)

    1976-01-01

    The third version of the Mini-Sniffer remotely-piloted research vehicle on Rogers Dry Lake, adjacent to NASA's Dryden Flight Research Center, Edwards, California. The futuristic-looking ground crew are in white, self-contained suits, because the engine on this third version of the Mini-Sniffer was powered by hydrazine, which is a very hazardous material. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the

  17. Noncultured Autologous Adipose-Derived Stem Cells Therapy for Chronic Radiation Injury

    Science.gov (United States)

    Akita, Sadanori; Akino, Kozo; Hirano, Akiyoshi; Ohtsuru, Akira; Yamashita, Shunichi

    2010-01-01

    Increasing concern on chronic radiation injuries should be treated properly for life-saving improvement of wound management and quality of life. Recently, regenerative surgical modalities should be attempted with the use of noncultured autologous adipose-derived stem cells (ADSCs) with temporal artificial dermis impregnated and sprayed with local angiogenic factor such as basic fibroblast growth factor, and secondary reconstruction can be a candidate for demarcation and saving the donor morbidity. Autologous adipose-derived stem cells, together with angiogenic and mitogenic factor of basic fibroblast growth factor and an artificial dermis, were applied over the excised irradiated skin defect and tested for Patients who were uneventfully healed with minimal donor-site morbidity, which lasts more than 1.5 years. PMID:21151652

  18. Noncultured Autologous Adipose-Derived Stem Cells Therapy for Chronic Radiation Injury

    Directory of Open Access Journals (Sweden)

    Sadanori Akita

    2010-01-01

    Full Text Available Increasing concern on chronic radiation injuries should be treated properly for life-saving improvement of wound management and quality of life. Recently, regenerative surgical modalities should be attempted with the use of noncultured autologous adipose-derived stem cells (ADSCs with temporal artificial dermis impregnated and sprayed with local angiogenic factor such as basic fibroblast growth factor, and secondary reconstruction can be a candidate for demarcation and saving the donor morbidity. Autologous adipose-derived stem cells, together with angiogenic and mitogenic factor of basic fibroblast growth factor and an artificial dermis, were applied over the excised irradiated skin defect and tested for Patients who were uneventfully healed with minimal donor-site morbidity, which lasts more than 1.5 years.

  19. Autologous conjunctiva transplantation with stem cells on edge of cornea for recurrent pterygium

    Directory of Open Access Journals (Sweden)

    Yun Wang

    2013-10-01

    Full Text Available AIM: To observe the clinical effectiveness and practicality the autologous conjunctiva transplantation with stem cells on edge of cornea for recurrent pterygium.METHODS: Of the 53 recurrent pterygium patients(57 eyes, after all pathological tissues were removed, underwent the autologous conjunctiva transplantation with stem cells on edge of cornea which were locked above conjunctival transplantation of the operated eye.RESULTS: Postopretive follow-up was 1-12 months for all 57 eyes, of which 3 eyes(5%relapsed. The corneoscleral autolysis was occurred in one eye and surgery treatment was conducted. Corneal wounds were healing and transplantations survived well for the remaining 53 patients without obvious surgical marks. Cure rate was 93%.CONCLUSION: Autologous conjunctiva transplantation with stem cells on edge of cornea for recurrent pterygium can meet the aesthetic requirements of the some patients, with the advantages of obtaining material easily, faster wound healing, lower postoperative recurrence rate, meeting the aesthetic needs of some patients and improving postoperative results. Thus, it is an ideal surgery and is worthy of applying on primary hospital.

  20. EFFICACY OF LOCAL INFILTRATION OF AUTOLOGOUS BLOOD VERSUS LOCAL CORTICOSTEROID INJECTION- THE TREATMENT OF CHRONIC TENNIS ELBOW

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar Roy

    2017-05-01

    Full Text Available BACKGROUND Chronic painful tendon disorders are common in both sport persons and common individuals. 1,2 Lateral epicondylitis (tennis elbow is relatively more common among active individuals in the general population. 3 Typical signs and symptoms include pain and tenderness over the lateral epicondyle, exacerbated by resisted wrist extension and passive wrist flexion and impaired grip strength. The aim of the study is to find whether autologous blood provides comparable functional outcome over local steroids and hence whether it can replace steroids in treatment of tennis elbow. MATERIALS AND METHODS Patients with nontraumatic elbow pain attending the Orthopaedics Outpatient Department of Nalanda Medical College Hospital from January 2016 to August 2016. The participating subjects were randomly grouped into two groups (steroid (Group A and autologous blood (Group B. Pain in the subject’s affected elbow was measured using Visual Analogue Score (VAS. RESULTS Initially, both the groups had comparable initial VAS scores. At 1 month follow up, steroid group showed a significantly greater improvement in mean VAS scores when compared to autologous blood group. However, at 6 months follow up, steroid group showed no statistically significant difference in mean VAS scores when compared to autologous blood group. CONCLUSION From the current study, we concluded that both local corticosteroid and autologous blood were equally efficacious in the treatment of chronic lateral epicondylitis of elbow.

  1. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Science.gov (United States)

    Perevalov, Denis

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for numu → nu e neutrino oscillations at Deltam 2 ˜ 1 eV2 using an intense neutrino flux with an average energy Enu ˜ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0x1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semi-inclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current pi 0, charged current quasi-elastic (CCQE), charged current pi +, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (nuN → nu N) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Deltas, this however requires a separation of NCE proton (nup → nu p) from NCE neutron (nun → nun ) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Deltas measurement. In this thesis MiniBooNE reports the NCE (n+p) cross-section, the measurement

  2. Recommended safety objectives, principles and requirements for mini-reactors

    International Nuclear Information System (INIS)

    1991-05-01

    Canadian and international publications containing objectives, principles and requirements for the safety of nuclear facilities in general and nuclear power plants in particular have been reviewed for their relevance to mini-reactors. Most of the individual recommendations, sometimes with minor wording changes, are applicable to mini-reactors. However, some prescriptive requirements for the shutdown, emergency core cooling and containment systems of power reactors are considered inappropriate for mini-reactors. The Advisory Committee on Nuclear Safety favours a generally non-prescriptive approach whereby the applicant for a mini-reactor license is free to propose any means of satisfying the fundamental objectives, but must convince the regulatory agency to that effect. To do so, a probabilistic safety assessment (PSA) would be the favoured procedure. A generic PSA for all mini-reactors of the same design would be acceptable. Notwithstanding this non-prescriptive approach, the ACNS considers that it would be prudent to require the existence of at least one independent shutdown system and two physically independent locations from which the reactor can be shut down and the shutdown condition monitored, and to require provision for an assumed loss of integrity of the primary cooling system's boundary unless convincing arguments to the contrary are presented. The ACNS endorses in general the objectives and fundamental principles proposed by the interorganizational Small Reactor Criteria working group, and intends to review and comment on the documents on specific applications to be issued by that working group

  3. Cryopreservation of boar semen in mini- and maxi-straws.

    Science.gov (United States)

    Bwanga, C O; de Braganca, M M; Einarsson, S; Rodriguez-Martinez, H

    1990-10-01

    Split ejaculates from four boars were frozen with a programmable freezing machine, in mini- (0.25 ml) and maxi- (5 ml) plastic straws with an extender at either acidic (6.3) or alkaline (7.4) pH. Glycerol (3%) was used as cryoprotectant. The freezing of the semen was monitored by way of thermocouples placed in the straws. Post-thaw motility and acrosome integrity were evaluated; the latter using phase contrast microscopy, eosin-nigrosin stain and electron microscopy. Post-thaw sperm motility was significantly higher when semen was frozen in mini-straws than in maxi-straws. For the mini-straws, the motility was better when semen was exposed to an acidic environment during freezing, but this beneficial effect of the low extracellular pH was not evident when maxi-straws were thawed. The motility of the spermatozoa diminished significantly during the thermoresistance test (0 h and 2 h time) at 37 degrees C in a similar way for both straws and extracellular pH's. The freezing procedure, no matter the extracellular pH, did not cause major acrosomal damages, but significantly more normal apical ridges were present in the mini-straws than in the maxi-straws. This in vitro evaluation indicated that the freezing method employed was better for mini- than for maxi-straws since the freezing of the 5 ml volumes was not homogeneous, due to the large section area between the surface and the core of the straw.

  4. A mini-microscope for in situ monitoring of cells†‡

    Science.gov (United States)

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R.; Hamilton, Geraldine A.; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E.

    2013-01-01

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost. PMID:22911426

  5. Impact of Mini-drone based Video Surveillance on Invasion of Privacy

    OpenAIRE

    Korshunov, Pavel; Bonetto, Margherita; Ebrahimi, Touradj; Ramponi, Giovanni

    2015-01-01

    An increase in adoption of video surveillance, affecting many aspects of daily lives, raises public concern about an intrusion into individual privacy. New sensing and surveillance technologies, such as mini-drones, threaten to eradicate boundaries of private space even more. Therefore, it is important to study the effect of mini-drones on privacy intrusion and to understand how existing protection privacy filters perform on a video captured by a mini-drone. To this end, we have built a publi...

  6. Human T-Cell Clones from Autoimmune Thyroid Glands: Specific Recognition of Autologous Thyroid Cells

    Science.gov (United States)

    Londei, Marco; Bottazzo, G. Franco; Feldmann, Marc

    1985-04-01

    The thyroid glands of patients with autoimmune diseases such as Graves' disease and certain forms of goiter contain infiltrating activated T lymphocytes and, unlike cells of normal glands, the epithelial follicular cells strongly express histocompatability antigens of the HLA-DR type. In a study of such autoimmune disorders, the infiltrating T cells from the thyroid glands of two patients with Graves' disease were cloned in mitogen-free interleukin-2 (T-cell growth factor). The clones were expanded and their specificity was tested. Three types of clones were found. One group, of T4 phenotype, specifically recognized autologous thyroid cells. Another, also of T4 phenotype, recognized autologous thyroid or blood cells and thus responded positively in the autologous mixed lymphocyte reaction. Other clones derived from cells that were activated in vivo were of no known specificity. These clones provide a model of a human autoimmune disease and their analysis should clarify mechanisms of pathogenesis and provide clues to abrogating these undesirable immune responses.

  7. Bortezomib consolidation after autologous stem cell transplantation in multiple myeloma

    DEFF Research Database (Denmark)

    Mellqvist, Ulf-Henrik; Gimsing, Peter; Hjertner, Oyvind

    2013-01-01

    The Nordic Myeloma Study Group conducted an open randomized trial to compare bortezomib as consolidation therapy given after high-dose therapy and autologous stem cell transplantation (ASCT) with no consolidation in bortezomib-naive patients with newly diagnosed multiple myeloma. Overall, 370...

  8. NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE

    Directory of Open Access Journals (Sweden)

    Tukiran Surbakti

    2016-03-01

    Full Text Available Abstract NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE. Research of UMo fuel for research reactor has been developing  right now. The fuel of  research reactor used is uranium low enrichment with high density. For supporting the development of fuel, an assessment of mini fuel in the RSG-GAS core was performed. The mini fuel are U7Mo-Al and U6Zr-Al with densitis of 7.0gU/cc and 5.2 gU/cc, respectively. The size of both fuel are the same namely 630x70.75x1.30 mm were inserted to the 3 plates of dummy fuel. Before being irradiated in the core, a calculation for safety analysis  from neutronics and thermohydrolics aspects were required. However, in this paper will discuss safety analysis of the U7Mo-Al and U6Zr-Al mini fuels from neutronic point of view.  The calculation was done using WIMSD-5B and Batan-3DIFF code. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. Power density of U7Mo-Al mini fuel bigger than U6Zr-Al fuel.   Key words: mini fuel, neutronics analysis, reactor core, safety analysis   Abstrak ANALISIS NEUTRONIK ELEMEN BAKAR UJI MINI DI TERAS RSG-GAS. Penelitian tentang bahan bakar UMo untuk reaktor riset terus berkembang saat ini. Bahan bakar reaktor riset yang digunakan adalah uranium pengkayaan rendah namun densitas tinggi.  Untuk mendukung pengembangan bahan bakar dilakukan uji elemen bakar mini di teras reakror RSG-GAS dengan tujuan menentukan jumlah siklus di dalam teras sehingga tercapai fraksi bakar maksimum. Bahan bakar yang diuji adalah U7Mo-Al dengan densitas 7,0 gU/cc dan U6Zr-Al densitas 5,2 gU/cc. Ukuran kedua bahan bakar uji tersebut adalah sama 630x70,75x1,30 mm dimasukkan masing masing kedalam 3 pelat dummy bahan bakar. Sebelum diiradiasi ke dalam teras reaktor maka perlu dilakukan perhitungan keselamatan baik secara neutronik maupun termohidrolik. Dalam makalah ini

  9. Autologous stem-cell transplantation in Hodgkin’s lymphoma: analysis of a therapeutic option

    Directory of Open Access Journals (Sweden)

    Adriano de Moraes Arantes

    2011-06-01

    Full Text Available Objective: To report the clinical progress of patients with Hodgkin’slymphoma treated with autologous transplantation after failure orrelapse of first-line treatment with chemotherapy and/or radiationtherapy. Methods: The results of a retrospective analysis of 31patients submitted to autologous transplantation as second-linetreatment, between April 2000 and December 2008, were analyzed.Fourteen men and seventeen women, with a median age of 27 years,were submitted to autologous transplantation for relapsed (n = 21or refractory (n = 10 Hodgkin’s lymphoma. Results: Mortalityrelated to treatment in the first 100 days after transplant was 3.2%.With a mean follow-up period of 18 months (range: 1 to 88 months,the probability of global survival and progression-free survival in18 months was 84 and 80%, respectively. The probability of globalsurvival and progression-free survival at 18 months for patients withchemosensitive relapses (n = 21 was 95 and 90%, respectively,versus 60 and 45% for patients with relapses resistant to chemotherapy(n = 10 (p = 0.001 for global survival; p = 0.003 for progressionfreesurvival. In the multivariate analysis, absence of disease or pretransplant disease < 5 cm were favorable factors for global survival (p= 0.02; RR: 0.072; 95%CI: 0.01-0.85 and progression-free survival (p= 0.01; RR: 0.040; 95%CI: 0.007-0.78. Conclusion: Autologous transplantation of stem-cells is a therapeutic option for Hodgkin’s lymphoma patients after the first relapse. Promising results were observed in patients with a low tumor burden at transplant.

  10. Review of autologous blood transfusion at the Kenyatta National ...

    African Journals Online (AJOL)

    Objective: This study was performed over a three- month period to establish the pattern of autologous blood transfusion with specific focus on age, sex, type of surgery, duration of hospital stay and religious beliefs. Design: Hospital based prospective study. Setting: The study was conducted at the Kenyatta National Hospital ...

  11. A DNA Mini-Barcoding System for Authentication of Processed Fish Products.

    Science.gov (United States)

    Shokralla, Shadi; Hellberg, Rosalee S; Handy, Sara M; King, Ian; Hajibabaei, Mehrdad

    2015-10-30

    Species substitution is a form of seafood fraud for the purpose of economic gain. DNA barcoding utilizes species-specific DNA sequence information for specimen identification. Previous work has established the usability of short DNA sequences-mini-barcodes-for identification of specimens harboring degraded DNA. This study aims at establishing a DNA mini-barcoding system for all fish species commonly used in processed fish products in North America. Six mini-barcode primer pairs targeting short (127-314 bp) fragments of the cytochrome c oxidase I (CO1) DNA barcode region were developed by examining over 8,000 DNA barcodes from species in the U.S. Food and Drug Administration (FDA) Seafood List. The mini-barcode primer pairs were then tested against 44 processed fish products representing a range of species and product types. Of the 44 products, 41 (93.2%) could be identified at the species or genus level. The greatest mini-barcoding success rate found with an individual primer pair was 88.6% compared to 20.5% success rate achieved by the full-length DNA barcode primers. Overall, this study presents a mini-barcoding system that can be used to identify a wide range of fish species in commercial products and may be utilized in high throughput DNA sequencing for authentication of heavily processed fish products.

  12. Augmentation of the Nasal Dorsum Using the Multistrip Autologous Cartilage Technique.

    Science.gov (United States)

    Liu, Liqiang; Bu, Zhaoyun; Fan, Jincai; Tian, Jia; Gan, Cheng; Yang, Zengjie; Jiao, Hu

    2017-12-01

    Nasal augmentation is a popular modern technique requested by many Asian people. There are two kinds of autologous cartilage used to augment the nose at present: carved as a monobloc or diced into pieces. Each approach has its pros and cons. The authors performed their surgical technique on a group of 28 patients. Twenty of these patients had undergone rhinoplasties performed before referral to our hospital; eight of these patients had undergone a primary rhinoplasty. Bilateral conchal, nasal septum, or rib cartilage was harvested; deep temporal fascia or abdominal muscle fascia to be prepared for packing stripped cartilage was also removed at this time. The cartilage was placed on a plastic cutting board and cut into strips with a transverse section of 1 × 1 mm. Then, these strips were packed and covered by fascia to form the grafts. The median follow-up was 23 months (range, 12 to 48 months). Twenty-two patients were satisfied with their augmented noses. Through examinations, biopsies, and magnetic resonance imaging scans, less resorption was observed with the multistrip autologous cartilage technique. Junctional stepoffs, excessive prominence, and slanting grafts occurred in three patients, two of whom had revisions. Using multistrip autologous cartilage grafts is an easier method to perform and could be another alternative technique for augmentative and reconstructive rhinoplasties.

  13. Mini mental state examination

    DEFF Research Database (Denmark)

    Kørner, Ejnar Alex; Lauritzen, Lise; Wang, August

    2008-01-01

    INTRODUCTION: The Mini Mental State Examination (MMSE) is widely used in Denmark, but often in non-validated versions. In 2000 a cross-sectional workgroup decided on a new common version of the MMSE with a corresponding manual, which is validated for the first time in the present study. MATERIALS...... the severity of dementia disorders. Udgivelsesdato: 2008-Feb-25...

  14. Implementing the undergraduate mini-CEX: a tailored approach at Southampton University.

    Science.gov (United States)

    Hill, Faith; Kendall, Kathleen; Galbraith, Kevin; Crossley, Jim

    2009-04-01

    The mini-clinical evaluation exercise (mini-CEX) is widely used in the UK to assess clinical competence, but there is little evidence regarding its implementation in the undergraduate setting. This study aimed to estimate the validity and reliability of the undergraduate mini-CEX and discuss the challenges involved in its implementation. A total of 3499 mini-CEX forms were completed. Validity was assessed by estimating associations between mini-CEX score and a number of external variables, examining the internal structure of the instrument, checking competency domain response rates and profiles against expectations, and by qualitative evaluation of stakeholder interviews. Reliability was evaluated by overall reliability coefficient (R), estimation of the standard error of measurement (SEM), and from stakeholders' perceptions. Variance component analysis examined the contribution of relevant factors to students' scores. Validity was threatened by various confounding variables, including: examiner status; case complexity; attachment specialty; patient gender, and case focus. Factor analysis suggested that competency domains reflect a single latent variable. Maximum reliability can be achieved by aggregating scores over 15 encounters (R = 0.73; 95% confidence interval [CI] +/- 0.28 based on a 6-point assessment scale). Examiner stringency contributed 29% of score variation and student attachment aptitude 13%. Stakeholder interviews revealed staff development needs but the majority perceived the mini-CEX as more reliable and valid than the previous long case. The mini-CEX has good overall utility for assessing aspects of the clinical encounter in an undergraduate setting. Strengths include fidelity, wide sampling, perceived validity, and formative observation and feedback. Reliability is limited by variable examiner stringency, and validity by confounding variables, but these should be viewed within the context of overall assessment strategies.

  15. A high-resolution mini-microscope system for wireless real-time monitoring.

    Science.gov (United States)

    Wang, Zongjie; Boddeda, Akash; Parker, Benjamin; Samanipour, Roya; Ghosh, Sanjoy; Menard, Frederic; Kim, Keekyoung

    2017-09-04

    Compact, cost-effective and high-performance microscope that enables the real-time imaging of cells and lab-on-a-chip devices is highly demanded for cell biology and biomedical engineering. This paper aims to present the design and application of an inexpensive wireless mini-microscope with resolution up to 2592 × 1944 pixels and speed up to 90 fps. The mini-microscope system was built on a commercial embedded system (Raspberry Pi). We modified a camera module and adopted an inverse dual lens system to obtain the clear field of view and appropriate magnification for tens of micrometer objects. The system was capable of capturing time-lapse images and transferring image data wirelessly. The entire system can be operated wirelessly and cordlessly in a conventional cell culturing incubator. The developed mini-microscope was used to monitor the attachment and proliferation of NIH-3T3 and HEK 293 cells inside an incubator for 50 hours. In addition, the mini-microscope was used to monitor a droplet generation process in a microfluidic device. The high-quality images captured by the mini-microscope enabled us an automated analysis of experimental parameters. The successful applications prove the great potential of the developed mini-microscope for monitoring various biological samples and microfluidic devices. This paper presents the design of a high resolution mini-microscope system that enables the wireless real-time imaging of cells inside the incubator. This system has been verified to be a useful tool to obtain high-quality images and videos for the automated quantitative analysis of biological samples and lab-on-a-chip devices in the long term.

  16. Protein incorporation by isolated amphibian oocytes. VI. Comparison of autologous and xenogeneic vitellogenins

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, R A; Deufel, R A; Misulovin, Z

    1980-01-01

    1. Labeled vitellogenins were isolated from the sera of several amphibians, a turtle, and a pigeon, and were incubated in vitro with oocytes from Xenopus laevis and Rana pipiens. 2. Oocytes from X. laevis sequestered vitellogenin from salamanders, turtle, and pigeon at rates comparable to that for autologous vitellogenin, while anuran vitellogenins were sequestered at somewhat lower rates. 3. Oocytes from R. pipiens sequestered X. laevis vitellogenin at a rate comparable to autologous vitellogenin, while salamander, turtle, and pigeon vitellogenins were sequestered at faster rates. 4. All vitellogenins examined appear to be recognized and incorporated specifically by X. laevis and R. pipiens oocytes.

  17. PARTICIPATION OF MINI-BASKETBALL PLAYERS DURING SMALL-SIDED COMPETITIONS

    Directory of Open Access Journals (Sweden)

    M\\u00AA Isabel Pi\\u00F1ar

    2009-01-01

    Full Text Available This study presents the differences of competition between mini-basketball with the traditional rules (5-a-side and minibasket with rule modifications (3-a-side such as: reduced number of players on court, compulsory participation in 2 of the match's 4 periods, reduced court size, placing the free throw line at 3m from the basket, and including a three-point line. The sample that was selected included 47 mini-basketball players, and the study was carried out using a quasi-experimental design without a control group. The aim was to determine the effect of rule modifications on the participation of the player with the ball. It was demonstrated that the degree of individual participation is greater in mini-basketball with modified rules.

  18. Two mini-preparation protocols to DNA extraction from plants with ...

    African Journals Online (AJOL)

    Were standardized two previously reported standard plant DNA extraction methods, but improved them on mini preparations to use the samples for population genetic analysis. The combination of CTAB lysis procedure-solvent extraction and DNA column purification (DNeasy plant mini kit modification) enables a faster and ...

  19. High-flying Mini-Sniffer RPV - Mars bound

    Science.gov (United States)

    Reed, R. D.

    1978-01-01

    The Mini-Sniffer is a small unmanned survey aircraft developed by NASA to conduct turbulence and atmospheric pollution measurements from ground level to an altitude of 90,000 ft. Carrying a 25-lb air sampling apparatus, the Mini-Sniffer typically cruises for one hour at 70,000 ft before being remotely piloted back to earth. A hydrazine monopropellant engine powers the craft, while a PCM telemetering system and a radar transponder provide control functions. Development of a high-performance low-Reynolds-number airfoil could make the research craft suitable for a low-altitude terrain-following mission on Mars.

  20. [Consensus of the Deutsche Gesellschaft der Plastischen, Rekonstruktiven und Ästhetischen Chirurgen (DGPRÄC) on Autologous Fat Grafting].

    Science.gov (United States)

    Giunta, R E; Horch, R E; Prantl, L; Baur, E M; Herold, C; Kamolz, L; Lehnhardt, M; Noah, E M; Rennekampff, O; Richter, D; Schaefer, D J; Ueberreiter, K

    2016-12-01

    On occasion of the Munich Plastic Symposium in Munich the board of the Deutsche Gesellschaft der Plastischen, Rekonstruktiven und Ästhetischen Chirurgen (DGPRÄC) together with a group of experts who were also involved in the preparation of the recently published S2K guideline "Autologous Fat Grafting", prepared a consensus statement from a plastic-surgical point of view so to evaluate current spects and taking into account the current legal framework: 1. Autologous Fat Grafting is a long established treatment in plastic surgery and does not differ from other tissue grafts. 2. Mechanical processing of autologous fat does not provide any substantial change tot he tissue. 3. If other treatment methods to enrich progenitor cells of autolous fat i. e. by an enzymatic process have evidence that autologous adipose tissue or cells were substantially changed, classification as a drug could come in question under current german law (application of AMG/ATMP). © Georg Thieme Verlag KG Stuttgart · New York.

  1. The Mini-Social Phobia Inventory: psychometric properties in an adolescent general population sample.

    Science.gov (United States)

    Ranta, Klaus; Kaltiala-Heino, Riittakerttu; Rantanen, Päivi; Marttunen, Mauri

    2012-07-01

    Onset of social phobia (SP) typically occurs in adolescence. Short screening instruments for its assessment are needed for use in primary health and school settings. The 3-item Mini-Social Phobia Inventory (SPIN) has demonstrated effectiveness in screening for generalized SP (GSP) in adults. This study examined the psychometrics of the Mini-SPIN in an adolescent general population sample. Three hundred fifty adolescents aged 12 to 17 years were clinically interviewed using the Schedule for Affective Disorders and Schizophrenia for School-Age Children-Present and Lifetime Version for identification of SP and other Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Axis I disorders, blind to their Mini-SPIN status. Associations between SP; subclinical SP; other anxiety, depressive, and disruptive disorders; and Mini-SPIN scores were examined, and diagnostic efficiency statistics were calculated. The association between Mini-SPIN scores and the generalized subtype of SP was also examined. As in adults, the Mini-SPIN items differentiated subjects with SP from those without. A score of 6 points or greater was found optimal in predicting SP with a sensitivity of 86%, specificity of 84%, and positive and negative predictive values of 26% and 99%. The Mini-SPIN also possessed discriminative validity, as scores were higher for adolescents with SP than they were for those with depressive, disruptive, and other anxiety disorders. The Mini-SPIN was also able to differentiate adolescents with GSP from the rest of the sample. The Mini-SPIN has good psychometrics for screening SP in adolescents from general population and may have value in screening for GSP. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Immediate breast reconstruction using autologous skin graft associated with breast implant.

    Science.gov (United States)

    Dutra, A K; Andrade, W P; Carvalho, S M T; Makdissi, F B A; Yoshimatsu, E K; Domingues, M C; Maciel, M S

    2012-02-01

    Immediate breast reconstruction with skin graft is still little mentioned in the literature. Follow-up studies regarding the technique aspects are particularly scarce. The objective was to detail immediate breast reconstruction using autologous skin graft. Patients (n = 49) who underwent mastectomies and autologous immediate breast reconstruction with skin graft associated with a breast implant at A. C. Camargo Hospital (São Paulo, Brazil) between January 2007 and July 2010 were included. Information on clinical data, technique details and clinical outcome were prospectively collected. Following mastectomy, the autologous full-thickness skin graft was obtained through an inframammary fold incision along the contralateral breast in most patients. The skin graft was placed on the surface of the pectoralis major muscle after adjustments to conform to the mastectomy defect. A minimum of 10-month follow-up period was established. Patients' age ranged from 35 to 55 years and all received a silicone gel textured surface implant to obtain the necessary breast mound. The mean surgical time was 45 min, and the mean amount of skin resection was 4.5 cm in the largest diameter. Follow-up ranged from 10 to 35 months (median 23). All patients had silicone-gel textured surface implants to perform the breast mound reconstruction. No complications were observed in 87.8% of reconstructions. Forty-six patients (94%) had no complaints about the donor-site aesthetics. The result was a breast mound with a central ellipse of healed skin graft. Three (6%) poor results were observed. Thirty-six patients (67%) reported the results as good or very good. Our results lead us to conclude that autologous skin graft provided a reliable option in immediate breast reconstruction to skin-sparing mastectomy defects. The technique accomplished a single-stage implant breast reconstruction when there is inadequate skin coverage. Copyright © 2011 British Association of Plastic, Reconstructive and

  3. Tourette Syndrome: A Mini-Review

    Directory of Open Access Journals (Sweden)

    Michal Novotny

    2018-03-01

    Full Text Available The purpose of this mini-review is to provide the latest information on epidemiology, pathophysiology, diagnosis, and treatment of Tourette syndrome (TS. The authors conducted a literature search of available sources describing the issue of tic disorders with special focus on TS and made a comparison and evaluation of relevant findings. The results of this mini-review indicate that TS is a complex disorder, which has a significant impact on the quality of life of both the patients and his/her family. Therefore, early and proper diagnosis and treatment are necessary in order to reduce or even eliminate both symptoms and social burden of the patient. This requires a multidisciplinary management approach in order to meet the patients’ special needs. Future research should focus on neuroimaging, new neurotransmitter targets, in functional neurosurgery, as well as the effect of non-pharmacological psychotherapies for these people.

  4. [Women boxing athletes' EMG of upper limbs and lumbar muscles in the training of air striking of straight punch].

    Science.gov (United States)

    Zhang, Ri-Hui; Kang, Zhi-Xin

    2011-05-01

    To study training effect of upper limbs and lumbar muscles in the proceed of air striking of straight punch by analyzing boxing athletes' changes of electromyogram (EMG). We measured EMG of ten women boxing athletes' upper arm biceps (contractor muscle), upper arm triceps (antagonistic muscle), forearm flexor muscle (contractor muscle), forearm extensor muscle (antagonistic muscle), and lumbar muscles by ME6000 (Mega Electronics Ltd.). The stipulated exercise was to do air striking of straight punch with loads of 2.5 kg of dumbbell in the hand until exhausted. In the proceed of exercise-induce exhausted, the descend magnitude and speed of median frequency (MF) in upper limb antagonistic muscle exceeded to contracting muscle, moreover, the work percentage showed that contractor have done a larger percentage of work than antagonistic muscle. Compared with world champion's EMG, the majority of ordinary athletes' lumbar muscles MF revealed non-drop tendency, and the work percentage showed that lumbar muscles had a very little percentage of work. After comparing the EMG test index in upper limb and lumbar muscle of average boxing athletes with that of the world champion, we find the testees lack of the training of upper limb antagonistic muscle and lumbar muscle, and more trainings aimed at these muscles need to be taken.

  5. Improving oocyte quality by transfer of autologous mitochondria from fully grown oocytes

    DEFF Research Database (Denmark)

    Kristensen, Stine Gry; Pors, Susanne Elisabeth; Andersen, Claus Yding

    2017-01-01

    options using autologous mitochondria to potentially augment pregnancy potential in ART. Autologous transfer of mitochondria from the patient's own germline cells has attracted much attention as a possible new treatment to revitalize deficient oocytes. IVF births have been reported after transfer...... of oogonial precursor cell-derived mitochondria; however, the source and quality of the mitochondria are still unclear. In contrast, fully grown oocytes are loaded with mitochondria which have passed the genetic bottleneck and are likely to be of high quality. An increased supply of such oocytes could...... with high quality mitochondria can be obtained from natural or stimulated ovaries and potentially be used to improve both quality and quantity of oocytes available for fertility treatment....

  6. Lysis of fresh human solid tumors by autologous lymphocytes activated in vitro with lectins

    International Nuclear Information System (INIS)

    Mazumder, A.; Grimm, E.A.; Zhang, H.Z.; Rosenberg, S.A.

    1982-01-01

    Human peripheral blood lymphocytes (PBL), obtained from patients with a variety of cancers, were incubated in vitro with phytohemagglutinin, concanavalin A, and crude or lectin-free T-cell growth factors. The lectin-activated PBL of nine patients were capable of lysing fresh autologous tumor during a 4-hr 51Cr release assay. Multiple metastases from the same patient were equivalently lysed by these activated autologous PBL. No lysis of fresh PBL or lectin-induced lymphoblast cell targets was seen, although tumor, PBL, and lymphoblast cells were shown to be equally lysable using allosensitized cells. The activated cells could be expanded without loss of cytotoxicity in crude or lectin-free T-cell growth factors. The generation of cells lytic to fresh autologous tumor was dependent on the presence of adherent cells, although the lytic cell itself was not adherent. Proliferation was not involved in the induction of lytic cells since equal lysis was induced in irradiated and nonirradiated lymphocytes. Lectin was not required in the lytic assay, and the addition of alpha-methyl-D-mannoside to concanavalin A-activated lymphoid cells did not increase the lysis of fresh tumor cells. Activation by lectin for 3 days appears to be an efficient and convenient method for generating human cells lytic to fresh autologous tumor. These lytic cells may be of value for studies of the cell-mediated lysis of human tumor and possibly for tumor immunotherapy as well

  7. THE PORTION OF AUTOLOGOUS BLOOD IN ORTHOPEDIC DEPARTMENT OF GENERAL HOSPITAL NOVA GORICA IN FIVE YEARS PERIOD (1996–2000

    Directory of Open Access Journals (Sweden)

    Janka Černe-Zavadlav

    2002-04-01

    Full Text Available Background. The presentation of autologous blood donation with analysis of used blood and the percentage of autologous blood on Orthopedic Department in the years 1996–2000.Methods. From card-index of autologous blood donors we analysed 363 preoperative autologous blood donations.We followed the number of doses in one patient and type of operating procedure.We analysed the usage of blood from transfusion issue protocols and the usage of postoperative autotransfusion from patient protocols.Results. 91% of all preoperative blood donations in our hospital in five years period were from Orthopedic Department. There were 280 operating procedures (hip and knee arthroplasty that needed blood transfusion. 196 of these (70% were included in preoperative blood donation programme. We collected 330 doses: 1 dose in 61 cases, 2 doses in 100, 3 doses in 34 and 4 doses in 1 case or 1.68 doses per patient. The relationship between used autologous and allogenic blood were 46 : 54 (doses or 38 : 62 (mL. Autologous blood represented 38% of all used blood on Orthopedic Department, only 11% of autologous blood were discarded.Conclusions. The program of preoperative blood donation is well organized on The Orthopedic Department of our Hospital. To our experience we make the most of profit of autotransfusion (to avoid risks of allogenic blood, optimal patient colaboration, low percentage of discarded blood with two predonated doses in combination with postoperative autotransfusion. Regard to The Law of Blood supply (may 2000 we are going to introduce this protocol of preoperative blood donation for all programed operating procedures in our Hospital, which need blood transfusion.

  8. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC) among a heterogeneous sample of long-term cancer survivors: a cross-sectional study.

    Science.gov (United States)

    Zucca, Alison; Lambert, Sylvie D; Boyes, Allison W; Pallant, Julie F

    2012-05-20

    The mini-Mental Adjustment to Cancer Scale (mini-MAC) is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. RUMM 2030 was used to analyse the mini-MAC data (n=851). Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI), response format, local dependency, targeting, item bias (or differential item functioning -DIF), and dimensionality. For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales - Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of adaptive and maladaptive coping, extensive modifications were

  9. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC among a heterogeneous sample of long-term cancer survivors: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Zucca Alison

    2012-05-01

    Full Text Available Abstract Background The mini-Mental Adjustment to Cancer Scale (mini-MAC is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. Methods RUMM 2030 was used to analyse the mini-MAC data (n=851. Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI, response format, local dependency, targeting, item bias (or differential item functioning -DIF, and dimensionality. Results For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales – Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. Conclusions The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of

  10. Treatment of articular cartilage lesions of the knee by microfracture or autologous chondrocyte implantation: a systematic review.

    Science.gov (United States)

    Oussedik, Sam; Tsitskaris, Konstantinos; Parker, David

    2015-04-01

    We performed a systematic review of the treatment of articular cartilage lesions of the knee by microfracture or autologous chondrocyte implantation to determine the differences in patient outcomes after these procedures. We searched PubMed/Medline, Embase, and The Cochrane Library databases in the period from January 10 through January 20, 2013, and included 34 articles in our qualitative analysis. All studies showed improvement in outcome scores in comparison with baseline values, regardless of the treatment modality. The heterogeneity of the results presented in the studies precluded a meta-analysis. Microfracture appears to be effective in smaller lesions and is usually associated with a greater proportion of fibrocartilage production, which may have an effect on durability and eventual failure. Autologous chondrocyte implantation is an effective treatment that may result in a greater proportion of hyaline-like tissue at the repair site, which may in turn have a beneficial effect on durability and failure; it appears to be effective in larger lesions. Autologous chondrocyte implantation with periosteum has been shown to be associated with symptomatic cartilage hypertrophy more frequently than autologous chondrocyte implantation with collagen membrane. Matrix-associated autologous chondrocyte implantation is technically less challenging than the other techniques available, and in lesions greater than 4 cm(2), it has been shown to be more effective than microfracture. Level IV, systematic review of Level I-IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Evolution of Autologous Chondrocyte Repair and Comparison to Other Cartilage Repair Techniques

    Directory of Open Access Journals (Sweden)

    Ashvin K. Dewan

    2014-01-01

    Full Text Available Articular cartilage defects have been addressed using microfracture, abrasion chondroplasty, or osteochondral grafting, but these strategies do not generate tissue that adequately recapitulates native cartilage. During the past 25 years, promising new strategies using assorted scaffolds and cell sources to induce chondrocyte expansion have emerged. We reviewed the evolution of autologous chondrocyte implantation and compared it to other cartilage repair techniques. Methods. We searched PubMed from 1949 to 2014 for the keywords “autologous chondrocyte implantation” (ACI and “cartilage repair” in clinical trials, meta-analyses, and review articles. We analyzed these articles, their bibliographies, our experience, and cartilage regeneration textbooks. Results. Microfracture, abrasion chondroplasty, osteochondral grafting, ACI, and autologous matrix-induced chondrogenesis are distinguishable by cell source (including chondrocytes and stem cells and associated scaffolds (natural or synthetic, hydrogels or membranes. ACI seems to be as good as, if not better than, microfracture for repairing large chondral defects in a young patient’s knee as evaluated by multiple clinical indices and the quality of regenerated tissue. Conclusion. Although there is not enough evidence to determine the best repair technique, ACI is the most established cell-based treatment for full-thickness chondral defects in young patients.

  12. A preliminary study of the mini-mental state examination in a Spanish child population.

    Science.gov (United States)

    Rubial-Alvarez, Sandra; Machado, María-Clara; Sintas, Elena; de Sola, Susana; Böhm, Peter; Peña-Casanova, Jordi

    2007-11-01

    The Mini-Mental State Examination is one of the most widely used screening tests for the adult population in daily neurologic practice. The aim of this study was to describe and to analyze the results of the Mini-Mental State Examination administered to Spanish children and to assess the relationship between Mini-Mental State Examination scores and the child's mental age/intelligence quotient. The study population included 181 children whose ages ranged between 4 and 12 years. The neuropsychologic battery consisted of the Mini-Mental State Examination and Kaufman Brief Intelligence Test. Percentiles were obtained for the Mini-Mental State Examination total score according to age ranges. Performance gradually increased from 4 to 10 years of age when a plateau in the total Mini-Mental State Examination score was reached. At the age of 6 years, results exceeded 24 on average. Pairwise mean comparisons showed statistically significant differences between the age groups (P Mini-Mental State Examination score correlated significantly with the child's chronologic (r = 0.80, P mental (r = 0.76, P Mini-Mental State Examination in a Spanish child population as well as a first step for the assessment of the usefulness of this instrument as a cognitive screening tool for children's development.

  13. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    Science.gov (United States)

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  14. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Perevalov, Denis [Univ. of Alabama, Tuscaloosa, AL (United States)

    2009-12-01

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for vμ → ve neutrino oscillations at Δm2 ~ 1 eV2 using an intense neutrino flux with an average energy Ev ~ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0 x 1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semiinclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current π0, charged current quasi-elastic (CCQE), charged current π+, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (vN → vN) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Δs, this however requires a separation of NCE proton (vp → vp) from NCE neutron (vn → vn) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Δs measurement. In this thesis

  15. Review of Strategies and Technologies for Demand-Side Management on Isolated Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Harper, Meg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-03-01

    This review provides an overview of strategies and currently available technologies used for demandside management (DSM) on mini-grids throughout the world. For the purposes of this review, mini-grids are defined as village-scale electricity distribution systems powered by small local generation sources and not connected to a main grid.1 Mini-grids range in size from less than 1 kW to several hundred kW of installed generation capacity and may utilize different generation technologies, such as micro-hydro, biomass gasification, solar, wind, diesel generators, or a hybrid combination of any of these. This review will primarily refer to AC mini-grids, though much of the discussion could apply to DC grids as well. Many mini-grids include energy storage, though some rely solely on real-time generation.

  16. Autologous hematopoietic stem cell transplantation in classical Hodgkin's lymphoma

    Directory of Open Access Journals (Sweden)

    Afonso José Pereira Cortez

    2011-02-01

    Full Text Available BACKGROUND: Hodgkin's lymphoma has high rates of cure, but in 15% to 20% of general patients and between 35% and 40% of those in advanced stages, the disease will progress or will relapse after initial treatment. For this group, hematopoietic stem cell transplantation is considered one option of salvage therapy. OBJECTIVES: To evaluate a group of 106 patients with Hodgkin's lymphoma, who suffered relapse or who were refractory to treatment, submitted to autologous hematopoietic stem cell transplantation in a single transplant center. METHODS: A retrospective study was performed with data collected from patient charts. The analysis involved 106 classical Hodgkin's lymphoma patients who were consecutively submitted to high-dose chemotherapy followed by autologous transplants in a single institution from April 1993 to December 2006. RESULTS: The overall survival rates of this population at five and ten years were 86% and 70%, respectively. The disease-free survival was approximately 60% at five years. Four patients died of procedure-related causes but relapse of classical Hodgkin's lymphoma after transplant was the most frequent cause of death. Univariate analysis shows that sensitivity to pre-transplant treatment and hemoglobin < 10 g/dL at diagnosis had an impact on patient survival. Unlike other studies, B-type symptoms did not seem to affect overall survival. Lactic dehydrogenase and serum albumin concentrations analyzed at diagnosis did not influence patient survival either. CONCLUSION: Autologous hematopoietic stem cell transplantation is an effective treatment strategy for early and late relapse in classical Hodgkin's lymphoma for cases that were responsive to pre-transplant chemotherapy. Refractory to treatment is a sign of worse prognosis. Additionally, a hemoglobin concentration below 10 g/dL at diagnosis of Hodgkin's lymphoma has a negative impact on the survival of patients after transplant. As far as we know this relationship has not

  17. Autologous Blood Pleurodesis In Patients With Persistent Air Leaks

    Directory of Open Access Journals (Sweden)

    Agkajanzadeh M

    2003-10-01

    Full Text Available Persistent air leaks occur after Spontaneous pneumothorax both primary and secondary, and after lungs trauma and lung surgeries are sever problems encountered chest surgeons with. Persistent air leak causes longer patients hospitalization."nMaterials and Methods: We used autologous blood pleurodesis in patients with persistent air leak for 30patients with more than 8 days air leaks, during a three years period 1377-1380 (1999-2002."nResults: The patients had 19 years up to 70 years old. Eight patients had thoracotomy and lobectomy and /or segmentectomies 6 with primary pneumothorax, 10 with secondary pneumothorax, and four with penetrated or blunt thoracic traumas. Blood was obtained from femoral or brachial veins and 70-150 mis. Injected in chest tubes. Chest bottle was first lied 80cm higher than body levels. After 24 hours repositioned in normal levels, and patients were supervised. Via chest tube we injected blood 70-100ml.for young patients, and 100-150 ml for older patients into intra pleural space. There were no clamped chest tubes. There were no pain, respiratory distress, fever, or cough in pleurodesized patients. The only patient's complaint was local pain in femoral vein or brachial vein because blood sampling and blood obtaining, although there was no local visible complication as hematoma or bleeding. After 48 hours in 24 patients air leak ceased. In six patients because persistent air leak autologous blood pleurodesis repeated, two patients after 48hours"nair leak ceased, remaining four patients underwent for thoracotomies, success rate"nwas 86.6%."nConclusion: According above success rate we suggest autologous blood pleurodesis in patients with persistent air leak is a reliable, effective, and no complicated procedure for persistent air leaks.

  18. Pengaruh Permaianan Bola Voli Mini Terhadap Peningkatan Kebugaran Jasmani Pecandu Narkoba

    Directory of Open Access Journals (Sweden)

    Kurnia Rismaningtyas

    2016-10-01

    Full Text Available This study aims to answer the following questions: 1 the influence of a volleyball mini-game model to increase physical fitness of drug addicts in prisons Women Class II A Semarang in 2015. 2 How big contribution volleyball mini model of the game due to the improvement of physical fitness of drug addicts in prisons Women Class II A Semarang in 2015. . T test results obtained tcount for data post test of 2,420 with significance 0.022 <0.05, which means that the average physical fitness between the experimental and control groups after treatment was significantly different. Judging from an average of 35.79 in the experimental group and the control group of 32.92 indicates that the level of physical fitness of women prisoners IIA class drug addict treatment Semarang made a game of volleyball mini-game is better than that do not follow the game of volleyball mini , In the experimental group increased physical fitness significantly, evident from the value t = 6.541 with a significance value of 0.000 <0.05. It was concluded that: 1 Model mini volleyball games that do can improve the physical fitness of inmates in prisons Women Class II A Semarang. 2 In the experimental group showed that the model of a volleyball mini-game has a significant influence on the improvement of physical fitness on female inmates in prison Women drug addicts Class II A Semarang.

  19. Mini-guide til DGNB

    DEFF Research Database (Denmark)

    Larsen, Tine Steen

    Guiden giver et kort indblik i formålet med de enkelte kriterier i en DGNB- bæredygtighedsvurdering, samt i hvordan der kan måles på kriterierne. Mini-guiden tager afsæt i systemet for certificering af Nybyggede kontor-og erhvervsbyggerier, som er det første og grundlæggende system i DGNB, som al...

  20. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics

    Directory of Open Access Journals (Sweden)

    El-Say Khalid M.

    2015-12-01

    Full Text Available This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1, swelling pressure of the superdisintegrant (X2, and the surface area of Aerosil as a glidant (X3. Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for preand post-compression characteristics. The prepared ODmini- tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2 and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  1. Autologous proliferative therapies in recalcitrant lateral epicondylitis.

    Science.gov (United States)

    Tetschke, Elisa; Rudolf, Margit; Lohmann, Christoph H; Stärke, Christian

    2015-09-01

    This study investigates the clinical effects of autologous conditioned plasma (ACP) injections and low-level laser application as therapy options for chronic lateral epicondylitis. A total of 52 patients with chronic lateral epicondylitis were evaluated in this study; 26 of these patients received three ACP injections and the control group, with 26 patients, received 12 laser applications, with standardized physical therapy for all patients afterward. Control examinations took place before treatment, after 2 and 6 mos, and in the 1 yr final follow-up. The control examination included the visual analog scale for pain and Disabilities of the Arm, Shoulder and Hand outcome measure scores. The analysis at final follow-up after 1 yr showed that both treatment options resulted in successful therapy outcome for the patients. In total, 63.5 % were successfully treated. Successful treatment was defined as more than 30% improvement in the visual analog score and more than 10.2 points in the Disabilities of the Arm, Shoulder and Hand score. Both groups showed a significant improvement in time response. This study demonstrates the beneficial effects of autologous proliferative therapies in the treatment of lateral epicondylitis. The data show that laser application and ACP therapy lead to a clinical improvement in epicondylopathia. Especially the new treatment with ACP can be highlighted as an alternative and as an easy-to-apply therapy option for clinical practice.

  2. Studying signal collection in the punch-through protection area of a silicon micro-strip sensor using a micro-focused X-ray beam

    CERN Document Server

    Poley, Anne-luise; The ATLAS collaboration

    2018-01-01

    For the Phase-II Upgrade of the ATLAS detector, a new, all-silicon tracker will be constructed in order to cope with the increased track density and radiation level of the High-Luminosity Large Hadron Collider. While silicon strip sensors are designed to minimise the fraction of dead material and maximise the active area of a sensor, concessions must be made to the requirements of operating a sensor in a particle physics detector. Sensor geometry features like the punch-through protection deviate from the standard sensor architecture and thereby affect the charge collection in that area. In order to study the signal collection of silicon strip sensors over their punch-through-protection area, ATLAS silicon strip sensors were scanned with a micro-focused X-ray beam at the Diamond Light Source. Due to the highly focused X-ray beam ($\\unit[2\\times3]{\\upmu\\text{m}}^2$) and the short average path length of an electron after interaction with an X-ray photon ($\\unit[\\leq2]{\\upmu\\text{m}}$), local signal collection i...

  3. Effects of Polarization on Mechanical Properties of Lead Zirconate Titanate Ceramics Evaluated by Modified Small Punch Tests

    Science.gov (United States)

    Deng, Qihuang; Fan, Yuchi; Wang, Lianjun; Xiong, Zhi; Wang, Hongzhi; Li, Yaogang; Zhang, Qinghong; Kawasaki, Akira; Jiang, Wan

    2012-01-01

    Pb(Zr,Ti)O3 (PZT) ceramics were prepared by the conventional mixed oxide method, and the strength of the resultant PZT ceramics was evaluated using modified small punch (MSP) tests. Load-displacement curve test results showed that the crack-initiation and fracture strengths of PZT ceramics decreased after polarization. The effect of the polarization accelerated the fatigue properties of PZT ceramics. Scanning electron microscopy (SEM) results showed that microcracks were formed before the maximum load in the MSP test, and the first load drop corresponded to crack initiation.

  4. Cost-effectiveness analysis of implants versus autologous perforator flaps using the BREAST-Q.

    Science.gov (United States)

    Matros, Evan; Albornoz, Claudia R; Razdan, Shantanu N; Mehrara, Babak J; Macadam, Sheina A; Ro, Teresa; McCarthy, Colleen M; Disa, Joseph J; Cordeiro, Peter G; Pusic, Andrea L

    2015-04-01

    Reimbursement has been recognized as a physician barrier to autologous reconstruction. Autologous reconstructions are more expensive than prosthetic reconstructions, but provide greater health-related quality of life. The authors' hypothesis is that autologous tissue reconstructions are cost-effective compared with prosthetic techniques when considering health-related quality of life and patient satisfaction. A cost-effectiveness analysis from the payer perspective, including patient input, was performed for unilateral and bilateral reconstructions with deep inferior epigastric perforator (DIEP) flaps and implants. The effectiveness measure was derived using the BREAST-Q and interpreted as the cost for obtaining 1 year of perfect breast health-related quality-adjusted life-year. Costs were obtained from the 2010 Nationwide Inpatient Sample. The incremental cost-effectiveness ratio was generated. A sensitivity analysis for age and stage at diagnosis was performed. BREAST-Q scores from 309 patients with implants and 217 DIEP flap reconstructions were included. The additional cost for obtaining 1 year of perfect breast-related health for a unilateral DIEP flap compared with implant reconstruction was $11,941. For bilateral DIEP flaps compared with implant reconstructions, the cost for an additional breast health-related quality-adjusted life-year was $28,017. The sensitivity analysis demonstrated that the cost for an additional breast health-related quality-adjusted life-year for DIEP flaps compared with implants was less for younger patients and earlier stage breast cancer. DIEP flaps are cost-effective compared with implants, especially for unilateral reconstructions. Cost-effectiveness of autologous techniques is maximized in women with longer life expectancy. Patient-reported outcomes findings can be incorporated into cost-effectiveness analyses to demonstrate the relative value of reconstructive procedures.

  5. Mini-Exame do Estado Mental: características psicométricas em idosos ambulatoriais Mini-Mental State Examination: psychometric characteristics in elderly outpatients

    Directory of Open Access Journals (Sweden)

    Roberto A Lourenço

    2006-08-01

    Full Text Available OBJETIVO: Avaliar as características de medida do Mini-Exame do Estado Mental em idosos atendidos em um ambulatório geral. MÉTODOS: O total de 303 indivíduos (>65 anos foi submetido à avaliação geriátrica com vários instrumentos, inclusive o Mini-Exame do Estado Mental. Foram calculadas a sensibilidade, a especificidade, os valores preditivos positivo e negativo e a curva ROC. RESULTADOS: A sensibilidade, a especificidade, os valores preditivos positivo e negativo e a área sob a curva ROC foram 80,8%, 65,3%, 44,7%, 90,7% e 0,807, respectivamente (ponto de corte 23/24. O melhor ponto de corte para indivíduos analfabetos foi 18/19 (sensibilidade =73,5%; especificidade =73,9%, e para aqueles com instrução escolar foi 24/25 (sensibilidade =75%; especificidade =69,7%. CONCLUSÕES: Para o rastreamento cognitivo de idosos atendidos em ambulatórios gerais pelo Mini-Exame do Estado Mental, a escolaridade deverá ser considerada para a adoção do ponto de corte mais adequado.OBJECTIVE: To assess the psychometric characteristics of the Mini-Mental State Examination in elderly outpatients who seek primary health care. METHODS: A total of 303 subjects (>65 years underwent comprehensive geriatric assessment with functional tools, including Mini-Mental State Examination. Sensitivity, specificity, positive predictive value, negative predictive value, and ROC curve were calculated. RESULTS: Sensitivity, specificity, positive and negative predictive values, and area under ROC curve were 80.8%, 65.3%, 44.7%, 90.7% and 0.807 respectively (cutoff point =23/24. The best cutoff point for illiterate was 18/19 (sensitivity =73.5%; specificity =73.9%; and for literate was 24/25 (sensitivity =75%; specificity =69.7%. CONCLUSIONS: While screening elderly outpatients for dementia, schooling must be considered in the choice of the best cutoff point in the Mini-Mental State Examination.

  6. Entrepreneur and Establishment of a Mini Hotel in XiChang, China

    OpenAIRE

    Hu, Mingsong

    2013-01-01

    Mini Hotel, is a new hotel will be opened in China in this year. I and 4 of my friends will be the shareholders of this Mini Hotel. The hotel is planned to be operating from the autumn of 2013. Now, everything in this thesis is on process. The main objective of this thesis was to draft an effective approach to ensure this is a right plan which is worth to invest. By using benchmarking and SWOT analysis we defined the strength and weakness of this Mini Hotel business plan. This thesis will ...

  7. Enrichment of autologous fat grafts with ex-vivo expanded adipose tissue-derived stem cells for graft survival

    DEFF Research Database (Denmark)

    Kølle, Stig-Frederik Trojahn; Fischer-Nielsen, Anne; Mathiasen, Anders Bruun

    2013-01-01

    Autologous fat grafting is increasingly used in reconstructive surgery. However, resorption rates ranging from 25% to 80% have been reported. Therefore, methods to increase graft viability are needed. Here, we report the results of a triple-blind, placebo-controlled trial to compare the survival ...... of fat grafts enriched with autologous adipose-derived stem cells (ASCs) versus non-enriched fat grafts....

  8. Model of competitive mini-hotel project life cycle

    OpenAIRE

    Левыкин, Виктор Макарович; Дэвон, Валерия Викторовна

    2014-01-01

    Having examined the situation in the hotel market of the city of Kharkov (Ukraine), it was found that one of the major shortcomings in the activities of mini-hotels is mediocre attitude towards customers, lack of proper attention and poor services. In this regard, there is the need to create a mini-hotel, the most important mission of which would be a genuine concern for guests and their comfort, as well as providing unique services of the highest class.For the success of this mission, it is ...

  9. Lexicography Problems and Theoretical Interpretation of Mini-Dictionaries

    Directory of Open Access Journals (Sweden)

    Jūratė Butkienė

    2011-04-01

    Full Text Available The article deals with principles of the word selection while compiling a mini-dictionary (containing a minimal number of words as well as with criteria and theoretical background thereof. The development of such principles is being analysed in Lithuania and abroad. The word selection while compiling a mini-dictionary of German language dedicated to the students of Civil engineering is being detailed. Furthermore, the article provides recommendations. The word selection has to be based on the linguistic statistics and on the thorough text analysis.

  10. Feasibility of a multiple-choice mini mental state examination for chronically critically ill patients.

    Science.gov (United States)

    Miguélez, Marta; Merlani, Paolo; Gigon, Fabienne; Verdon, Mélanie; Annoni, Jean-Marie; Ricou, Bara

    2014-08-01

    Following treatment in an ICU, up to 70% of chronically critically ill patients present neurocognitive impairment that can have negative effects on their quality of life, daily activities, and return to work. The Mini Mental State Examination is a simple, widely used tool for neurocognitive assessment. Although of interest when evaluating ICU patients, the current version is restricted to patients who are able to speak. This study aimed to evaluate the feasibility of a visual, multiple-choice Mini Mental State Examination for ICU patients who are unable to speak. The multiple-choice Mini Mental State Examination and the standard Mini Mental State Examination were compared across three different speaking populations. The interrater and intrarater reliabilities of the multiple-choice Mini Mental State Examination were tested on both intubated and tracheostomized ICU patients. Mixed 36-bed ICU and neuropsychology department in a university hospital. Twenty-six healthy volunteers, 20 neurological patients, 46 ICU patients able to speak, and 30 intubated or tracheostomized ICU patients. None. Multiple-choice Mini Mental State Examination results correlated satisfactorily with standard Mini Mental State Examination results in all three speaking groups: healthy volunteers: intraclass correlation coefficient = 0.43 (95% CI, -0.18 to 0.62); neurology patients: 0.90 (95% CI, 0.82-0.95); and ICU patients able to speak: 0.86 (95% CI, 0.70-0.92). The interrater and intrarater reliabilities were good (0.95 [0.87-0.98] and 0.94 [0.31-0.99], respectively). In all populations, a Bland-Altman analysis showed systematically higher scores using the multiple-choice Mini Mental State Examination. Administration of the multiple-choice Mini Mental State Examination to ICU patients was straightforward and produced exploitable results comparable to those of the standard Mini Mental State Examination. It should be of interest for the assessment and monitoring of the neurocognitive

  11. Summer Mini Atomiade June 2016

    CERN Multimedia

    Staff Association

    2016-01-01

    The Mini Atomiade are coming to CERN! Members of Clubs supported by the CERN Staff Association and in conjunction with ASCERI (Association of the Sports Communities of the European Research Institutes) will be organising the summer games at the beginning of June. ASCERI aims to contribute to a united Europe through regular sports meetings, bringing together members of public Research Institutes at European level. The Association's members come from over 40 Research Institutes spanning 16 countries. Numerous sports and leisure activities are represented at regular events and each tournament is organised by a different research institute. Clubs in conjunction with the CERN Staff Association have sent teams to previous winter and summer games and now, the CERN Club’s Coordination Committee (CCC) has now taken on the challenge of organising a Mini Atomiade from Friday June 3rd to Monday June 6th 2016 in Divonne-les-Bains. The games are made up of four different tournaments/competitions: Small Fi...

  12. Flexible Ureterorenoscopy versus Mini-Percutaneous Nephrolithotomy for the Treatment of Renal Stones.

    Science.gov (United States)

    Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan

    2018-04-22

    To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.

  13. Autologous Fat Transfer for Thumb Carpometacarpal Joint Osteoarthritis: A Prospective Study.

    Science.gov (United States)

    Herold, Christian; Rennekampff, Hans-Oliver; Groddeck, Robert; Allert, Sixtus

    2017-08-01

    Most operations for carpometacarpal joint osteoarthritis of the thumb irreversibly alter or destroy the anatomy. There is a high demand for minimally invasive alternatives. The authors report the results of autologous fat transfer for treatment of thumb carpometacarpal joint osteoarthritis. In a prospective study, 50 patients with thumb carpometacarpal joint osteoarthritis were observed for 1 year after autologous fat transfer. Manual liposuction and centrifugation were performed. Pain rating according to visual analogue pain scale; objective force of pinch grip and fist closure; and Disabilities of the Arm, Shoulder, and Hand questionnaire scores before and after treatment were analyzed. The average pain in stage 2 patients preoperatively was 7.7 ± 1.3; it was 1.8 ± 1.9 after 6 months and 2.4 ± 3.1 after 12 months. Patients with stage 2 osteoarthritis demonstrated a superior benefit from this treatment compared with patients with either stage 3 or stage 4 thumb carpometacarpal joint osteoarthritis. There were similar improvements for the parameters strength and Disabilities of the Arm, Shoulder, and Hand questionnaire score. No serious adverse events were observed. Autologous fat transplantation is an appealing alternative, especially in early-stage basal joint osteoarthritis of the thumb. The low invasiveness of the procedure and early recovery of patients compared with classical procedures such as trapeziectomy, and the superior long-term results compared with classical injection therapy, make this approach feasible as a first-line therapy in early-stage basal joint osteoarthritis of the thumb. Therapeutic, IV.

  14. Methodology for fabrication of hydraulics mini turbines with composite materials; Metodologia para a fabricacao de mini turbinas hidraulicas com materiais compostos

    Energy Technology Data Exchange (ETDEWEB)

    Faria, M.T.C. [Universidade Federal de Minas Gerais (DEMEC/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica], Email: mtcdf@uol.com.br; Martinez, C.B.; Viana, E.M.F. [Universidade Federal de Minas Gerais (EHR-UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Hidraulica e Recursos Hidricos], Emails: martinez@cce.ufmg.br, ednamariafaria@bol.com.br

    2009-07-01

    This paper presents the description of methodological procedure specially developed for manufacturing mini turbines. This procedure is used in the design of a Francis type mini turbine with 12.5 kW. The housing volute and the suction tube of this equipment are manufactured with using composed material based on glass fiber and its distributor system is manufactured with stainless steel and brass. At the end it is presented an estimate cost of design / manufacturing of such equipment and a comparison with other equipment in the market.

  15. Methods for roof-top mini-arrays

    Science.gov (United States)

    Hazen, W. E.; Hazen, E. S.

    1985-08-01

    To test the idea of the Linsley effect mini array for the study of giant air showers, it is desirable to have a trigger that exploits the effect itself. In addition to the trigger, it is necessary to have a method for measuring the relative arrival times of the particle swarm selected by the trigger. Since the idea of mini arrays is likely to appeal to small research groups, it is desirable to try to design relatively simple and inexpensive methods, and methods that utilize existing detectors. Clusters of small detectors have been designed for operation in the local particle density realm where the probability of or = 2 particles per detector is small. Consequently, this method can discriminate pulses from each detector and thenceforth deal mainly with logic pulses.

  16. Styles of coping with cancer: the Italian version of the Mini-Mental Adjustment to Cancer (Mini-MAC) scale.

    Science.gov (United States)

    Grassi, Luigi; Buda, Patrizia; Cavana, Laura; Annunziata, Maria Antonietta; Torta, Riccardo; Varetto, Antonella

    2005-02-01

    Mental adjustment to cancer has been explored in a large body of the literature by using the Mental Adjustment to Cancer (MAC) scale. Problems in the factor structure of the scale and the need for refining the instrument have determined the development of the Mini-MAC. The aim of this study was to validate, according to a test-oriented approach, the Italian version of the Mini-MAC. Four hundred and thirty cancer patients in five centres in Northern Italy completed the Mini-MAC and the Brief Symptom Inventory (BSI). A subgroup of 153 patients filled out the instruments again within 3 months of the first assessment. The five original subscales (Fighting Spirit, Hopeless, Fatalism, Anxious Preoccupation and Cognitive Avoidance) showed acceptable levels of reliability (Cronbach alpha coefficients ranging from 0.55 to 0.80) although alphas were lower for the scales Fighting Spirit and Fatalism. Factor analysis (Varimax rotation) identified the same five factors with minor variations from the original version. Again, alpha coefficients were less robust for the factors Fighting Sprit and Fatalism. Hopeless and Anxious Preoccupation were significantly related to all the BSI psychological stress symptoms, including the Global Stress Index (GSI). Test-retest reliability showed no differences in the sub-scales scores between assessments. Copyright (c) 2004 John Wiley & Sons, Ltd.

  17. Protective factor screening for prevention practice: Sensitivity and specificity of the DESSA-Mini.

    Science.gov (United States)

    Shapiro, Valerie B; Kim, B K Elizabeth; Robitaille, Jennifer L; LeBuffe, Paul A

    2017-12-01

    The Devereux Student Strengths Assessment Mini (DESSA-Mini; Naglieri, LeBuffe, & Shapiro, 2011/2014) was designed to overcome practical obstacles to universal prevention screening. This article seeks to determine whether an entirely strength-based, 8-item screening instrument achieves technical accuracy in routine practice. Data come from a district-wide implementation of a new social emotional learning (SEL) initiative designed to promote students' social-emotional competence. All students, kindergarten through Grade 8, were screened using the DESSA-Mini. A random 5 students per classroom received additional assessment. Concurrent and predictive criterion studies were conducted using the full DESSA as well as administrative records of serious disciplinary infraction. The DESSA-Mini showed excellent internal reliability, exceeding .90. Negligible to small differences were found between scores on the DESSA-Mini screen and the DESSA full assessment. Classification consistency between the DESSA-Mini and the DESSA was high (87%-94%) in routine practice, with sensitivity and specificity estimates exceeding Glascoe's (2005) standards. Finally, predictive validity of the DESSA-Mini was reliable; students screened as having a Need for SEL Instruction at the beginning of the year were 4.5 times more likely to have a record of serious disciplinary infraction at the end of the school year compared with those who were not identified (p mental, emotional, and behavioral problems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Mini-conference on Angular Momentum Transport in Laboratory and Nature

    International Nuclear Information System (INIS)

    Ji, Hantao; Kronberg, Philipp; Prager, Stewart C.; Uzdensky, Dmitri A.

    2008-01-01

    This paper provides a concise summary of the current status of the research and future perspectives discussed in the Mini-Conference on Angular Momentum Transport in Laboratory and Nature. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2007 Annual Meeting (November 12-16, 2007). This Mini-conference covers a wide range of phenomena happening in fluids and plasmas, either in laboratory or in nature. The purpose of this paper is not to comprehensively review these phenomena, but to provide a starting point for interested readers to refer to related research in areas other than their own

  19. Effect of BCNU combined with total body irradiation or cyclophosphamide on survival of dogs after autologous marrow grafts

    International Nuclear Information System (INIS)

    Paterson, A.H.G.; English, D.

    1979-01-01

    Dogs were treated with either: (1) 750 rad total body irradiation; (2) BCNU 2 or 4 mg/kg IV 48 hours prior to 750 rad total body irradiation; or (3) BCNU 4 mg/kg IV plus cyclophosphamide 30 mg/kg IV. Results showed that of 11 dogs who received 750 rad total body irradiation and did not receive cryopreserved autologous bone marrow cells, none survived, compared to an 88% survival (31 of 35 dogs) after 750 rad total body irradiation if the dogs received stored autologous bone marrow cells. However, when the dogs were treated with BCNU 2 or 4 mg/kg prior to 750 rad total body irradiation the survival rate, despite infusion of autologous bone marrow cells, dropped to 25% (3 of 12 dogs) for BCNU 2 mg/kg, and 17% (2 of 12 dogs) for BCNU 4 mg/kg. This effect did not seem to be due to direct serum inhibition of hemopoietic cell proliferation since serum obtained at various intervals after BCNU administrations failed to inhibit CFU growth in vitro. The dogs died from hemorrhage and infection; at autopsy there was hemorrhagic pneumonitis and intestinal ulcerations with petechial hemorrhages, suggesting that the combination of BCNU and total body irradiation may have synergistic toxicity on the canine gastro-intestinal tract. When BCNU was combined with cyclophosphamide, reversal of marrow toxicity occurred in 54% (6 of 11 dogs) with stored autologous bone marrow cells compared to no survival (0 of 8 dogs) with stored autologous bone marrow cells. Thus while autologous bone marrow grafts are useful for reversal of marrow toxicity due to many therapeutic protocols, such grafts alone may not provide protection against toxicity due to the combination of high dosage BCNU and total body irradiation

  20. Intra-arterial Autologous Bone Marrow Cell Transplantation in a Patient with Upper-extremity Critical Limb Ischemia

    International Nuclear Information System (INIS)

    Madaric, Juraj; Klepanec, Andrej; Mistrik, Martin; Altaner, Cestmir; Vulev, Ivan

    2013-01-01

    Induction of therapeutic angiogenesis by autologous bone marrow mononuclear cell transplantation has been identified as a potential new option in patients with advanced lower-limb ischemia. There is little evidence of the benefit of intra-arterial cell application in upper-limb critical ischemia. We describe a patient with upper-extremity critical limb ischemia with digital gangrene resulting from hypothenar hammer syndrome successfully treated by intra-arterial autologous bone marrow mononuclear cell transplantation.

  1. High dose therapy with autologous stem cell support in malignant disorders

    International Nuclear Information System (INIS)

    Holte, H.; Kvaloey, S.O.; Engan, T.

    1996-01-01

    New biomedical knowledge may improve the diagnostic procedures and treatment provided by the Health Services, but at additional cost. In a social democratic health care system, the hospital budgets have no room for expensive, new procedures or treatments, unless these are funded through extra allocation from the central authorities. High dose therapy with autologous stem cell support in malignant disorders is an example of a new and promising, but rather expensive treatment, but its role in cancer therapy has yet to be established. The indications for testing high dose therapy with autologous stem cell support in various malignancies are discussed, with emphasis on the principles for deciding which categories of disease should have priority. The authors suggest some malignant disorder for which high dose therapy with stem cell support should be explored versus conventional treatment in randomized prospective trials. 8 refs., 1 tab

  2. Rational Design of Mini-Cas9 for Transcriptional Activation.

    Science.gov (United States)

    Ma, Dacheng; Peng, Shuguang; Huang, Weiren; Cai, Zhiming; Xie, Zhen

    2018-04-20

    Nuclease dead Cas9 (dCas9) has been widely used for modulating gene expression by fusing with different activation or repression domains. However, delivery of the CRISPR/Cas system fused with various effector domains in a single adeno-associated virus (AAV) remains challenging due to the payload limit. Here, we engineered a set of downsized variants of Cas9 including Staphylococcus aureus Cas9 (SaCas9) that retained DNA binding activity by deleting conserved functional domains. We demonstrated that fusing FokI nuclease domain to the N-terminal of the minimal SaCas9 (mini-SaCas9) or to the middle of the split mini-SaCas9 can trigger efficient DNA cleavage. In addition, we constructed a set of compact transactivation domains based on the tripartite VPR activation domain and self-assembled arrays of split SpyTag:SpyCatch peptides, which are suitable for fusing to the mini-SaCas9. Lastly, we produced a single AAV containing the mini-SaCas9 fused with a downsized transactivation domain along with an optimized gRNA expression cassette, which showed efficient transactivation activity. Our results highlighted a practical approach to generate down-sized CRISPR/Cas9 and gene activation systems for in vivo applications.

  3. Targeted CNS delivery using human MiniPromoters and demonstrated compatibility with adeno-associated viral vectors

    Directory of Open Access Journals (Sweden)

    Charles N de Leeuw

    2014-01-01

    Full Text Available Critical for human gene therapy is the availability of small promoters tools to drive gene expression in a highly specific and reproducible manner. We tackled this challenge by developing human DNA MiniPromoters (MiniPs using computational biology and phylogenetic conservation. MiniPs were tested in mouse as single-copy knock-ins at the Hprt locus on the X chromosome and evaluated for lacZ reporter expression in central nervous system (CNS and non–CNS tissue. Eighteen novel MiniPs driving expression in mouse brain were identified, 2 MiniPs for driving pan-neuronal expression and 17 MiniPs for the mouse eye. Key areas of therapeutic interest were represented in this set: the cerebral cortex, embryonic hypothalamus, spinal cord, bipolar and ganglion cells of the retina, and skeletal muscle. We also demonstrated that three retinal ganglion cell MiniPs exhibit similar cell type specificity when delivered via adeno-associated virus vectors intravitreally. We conclude that our methodology and characterization has resulted in desirable expression characteristics that are intrinsic to the MiniPromoter, not dictated by copy-number effects or genomic location, and results in constructs predisposed to success in adeno-associated virus. These MiniPs are immediately applicable for preclinical studies toward gene therapy in humans and are publicly available to facilitate basic and clinical research, and human gene therapy.

  4. Is effective mass in combat sports punching above its weight?

    Science.gov (United States)

    Lenetsky, Seth; Nates, Roy J; Brughelli, Matt; Harris, Nigel K

    2015-04-01

    The segmental and muscular complexity of the human body can result in challenges when examining the kinetics of impacts. To better understand this complexity, combat sports literature has selected effective mass as a measure of an athlete's inertial contribution to the momentum transfer during the impact of strikes. This measure helps to clarify the analysis of striking kinetics in combat sports. This paper will review: (1) effective mass as a concept and its usage as a measure of impact intensity in combat sports, (2) the neuromuscular pattern known as "double peak muscle activation" which has been theorized to help enhance initial hand velocity upon impact and joint stiffening during impact, (3) the methods and equations used to calculate effective mass, and (4) practitioner recommendations based on the literature. We will argue in this manuscript that the act of punching presents unique challenges to the current understanding of effective mass due to additional force application during impact. This review will improve the understanding of effective mass and its roles in effective striking serving to underpin future research into performance enhancement in striking based combat sports. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Use of autologous platelet - Rich plasma in the treatment of intrabony defects

    Directory of Open Access Journals (Sweden)

    Sharath K Shetty

    2009-01-01

    Treatment of intrabony defects by autologous PRP gel alone caused significant soft tissue clinical improvement as well as hard tissue defect fill as evidenced by SSD view in spiral computed tomography.

  6. The Benefit of Microskin in Combination With Autologous Keratinocyte Suspension to Treat Full Skin Loss In Vivo.

    Science.gov (United States)

    Yuru, Shang; Dawei, Li; Chuanan, Shen; Kai, Yin; Li, Ma; Longzhu, Li; Dongxu, Zhao; Wenfeng, Cheng

    Patients with extensive deep burns often lack enough autologous skin to cover the wounds. This study explores a new method using microskin in combination with autologous keratinocytes in the treatment of extensive deep burn. Wounds in the combination group were treated with automicroskin at an area expansion ratio of 20:1 (wound area to automicroskin area) and autologous keratinocyte suspension, which were compared with the following treatments: no autotransplant, only allografts (control group); autologous keratinocyte suspension only (keratinocyte only group); automicroskin at an area expansion ratio of 20:1 (20:1 group); and automicroskin at an area expansion ratio of 10:1 (10:1 group, positive control). The authors used epithelialization rate (epithelialized area on day 21 divided by original wound area), hematoxylin and eosin staining, laminin, and type IV collagen immunohistochemistry to assess wound healing. The epithelialization rate of combination group (74.2% ± 8.0%) was similar to that of 10: 1 group (84.3% ± 11.9%, P = .085) and significantly (P < .05) higher than that of 20:1 group (59.2% ± 10.8%), keratinocyte only group (53.8% ± 11.5%), and control group (22.7% ± 5.5%). The hematoxylin and eosin staining and immunohistochemistry showed the epithelialization in the combination group was better than that in the keratinocyte only group and control group. Microskin in combination with autologous keratinocyte suspension can promote the reepithelialization of full-thickness wounds and reduce the requirements for automircoskin, and it is a useful option in the treatment of extensive deep burns.

  7. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Directory of Open Access Journals (Sweden)

    LuisJoaquín Garcia-Lopez

    Full Text Available Social Anxiety Disorder (SAD is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain.The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1 and clinical sample (study 2.Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls. Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency.Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  8. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Science.gov (United States)

    Garcia-Lopez, LuisJoaquín; Moore, Harry T A

    2015-01-01

    Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  9. Determinants of the Use of Autologous Blood in Elective General ...

    African Journals Online (AJOL)

    Objective: The study reports the 7 year experience of the authors with autologous blood transfusion in elective general surgery using the predeposit method. Material and Method: Patients aged 18 years and older, presenting for elective surgery and for whom blood donation was required were encouraged to predonate one ...

  10. Is there evidence that barrier membranes prevent bone resorption in autologous bone grafts during the healing period? A systematic review

    NARCIS (Netherlands)

    Gielkens, Pepijn F. M.; Bos, Ruud R. M.; Raghoebar, Gerry M.; Stegenga, Boudewijn

    2007-01-01

    Introduction: Autologous bone is considered the "reference standard" for bone-grafting procedures. A barrier membrane covering an autologous bone graft (guided bone regeneration [GBR]) is expected to prevent graft resorption. Good clinical results have been reported for GBR, although potential

  11. A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak.

    Science.gov (United States)

    Kılıç, Burcu; Erşen, Ezel; Demirkaya, Ahmet; Kara, H Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif

    2017-09-01

    Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery.

  12. Autologous osteochondral mosaicplasty or TruFit plugs for cartilage repair.

    Science.gov (United States)

    Hindle, Paul; Hendry, Jane L; Keating, John F; Biant, Leela C

    2014-06-01

    Autologous osteochondral mosaicplasty and TruFit Bone graft substitute plugs are methods used to repair symptomatic articular cartilage defects in the adult knee. There have been no comparative studies of the two techniques. This retrospective study assessed functional outcome of patients using the EQ-5D, Knee Injury and Osteoarthritis Outcome Score (KOOS) and Modified Cincinnati scores at follow-up of 1-5 years. There were 66 patients in the study (35 TruFit and 31 Mosaicplasty): 44 males and 22 females with a mean age of 37.3 years (SD 12.6). The mean BMI was 26.8. Thirty-six articular cartilage lesions were due to trauma, twenty-six due to osteochondritis dissecans and three due to non-specific degenerative change or unknown. There was no difference between the two groups age (n.s.), sex (n.s.), BMI (n.s.), defect location (n.s.) or aetiology (n.s.). The median follow-up was 22 months for the TruFit cohort and 30 months for the mosaicplasty group. There was no significant difference in the requirement for re-operation (n.s). Patients undergoing autologous mosaicplasty had a higher rate of returning to sport (p = 0.006), lower EQ-5D pain scores (p = 0.048) and higher KOOS activities of daily living (p = 0.029) scores. Sub-group analysis showed no difference related to the number of cases the surgeon performed. Patients requiring re-operation had lower outcome scores regardless of their initial procedure. This study demonstrated significantly better outcomes using two validated outcome scores (KOOS, EQ-5D), and an ability to return to sport in those undergoing autologous mosaicplasty compared to those receiving TruFit plugs. IV.

  13. Arc-to-arc mini-sling 1999: a critical analysis of concept and technology

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2011-04-01

    Full Text Available PURPOSE: The aim of this study was to critically review the Arc-to-Arc mini-sling (Palma's technique a less invasive mid-urethral sling using bovine pericardium as the sling material. MATERIALS AND METHODS: The Arc-to-Arc mini-sling, using bovine pericardium, was the first published report of a mini-sling, in 1999. The technique was identical to the "tension-free tape" operation, midline incision and dissection of the urethra. The ATFP (white line was identified by blunt dissection, and the mini-sling was sutured to the tendinous arc on both sides with 2 polypropylene 00 sutures. RESULTS: The initial results were encouraging, with 9/10 patients cured at the 6 weeks post-operative visit. However, infection and extrusion of the mini-sling resulted in sling extrusion and removal, with 5 patients remaining cured at 12 months. CONCLUSION: The Arc-to-Arc mini-sling was a good concept, but failed because of the poor technology available at that time. Further research using new materials and better technology has led to new and safer alternatives for the management of stress urinary incontinence.

  14. Successful autologous hematopoietic stem cell transplantation for a patient with rapidly progressive localized scleroderma.

    Science.gov (United States)

    Nair, Velu; Sharma, Ajay; Sharma, Sanjeevan; Das, Satyaranjan; Bhakuni, Darshan S; Narayanan, Krishnan; Nair, Vivek; Shankar, Subramanian

    2015-03-01

    Autologous hematopoietic stem cell transplant (HSCT) for rapidly progressive disease has not been reported in localized scleroderma. Our patient, a 16-year-old girl had an aggressive variant of localized scleroderma, mixed subtype (linear-generalized) with Parry Romberg syndrome, with no internal organ involvement, that was unresponsive to immunosuppressive therapy and was causing rapid disfigurement. She was administered autologous HSCT in June 2011 and has maintained drug-free remission with excellent functional status at almost 3.5 years of follow-up. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  15. Performance and internal flow condition of mini centrifugal pump with splitter blades

    International Nuclear Information System (INIS)

    Shigemitsu, T; Fukutomi, J; Kaji, K; Wada, T

    2012-01-01

    Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, mini centrifugal pumps with simple structure were investigated by this research. Splitter blades were adopted in this research to improve the performance and the internal flow condition of mini centrifugal pump which had large blade outlet angle. The original impeller without the splitter blades and the impeller with the splitter blades were prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the splitter blades on performance and internal flow condition of mini centrifugal pump. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-CFX) to investigate the internal flow condition in detail. It is clarified from the experimental results that the performance of the mini centrifugal pump is improved by the effect of the splitter blades. The blade-to-blade low velocity regions are suppressed in the case with the splitter blades and the total pressure loss regions are decreased. The effects of the splitter blades on the performance and the internal flow condition are discussed in this paper.

  16. Effect of recycling protocol on mechanical strength of used mini-implants.

    Science.gov (United States)

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 followed by sonication for cleaning before and after sandblasting (Al2O3-90 µ) and autoclave sterilization. G2 and G3 mini-implants were weighed after recycling process to evaluate weight loss (W). All the screws were broken to determine the fracture torque (FT). The influence of recycling process on FT and W was evaluated by ANOVA, Mann-Whitney, and multiple linear regression analysis. Results. FT was not influenced by recycling protocols even when sandblasting was added. Sandblasting caused weight loss due to abrasive mechanical stripping of screw surface. Screw diameter was the only variable that affected FT. Conclusions. Torsional strengths of screws that underwent the recycling protocols were not changed. Thus, screw diameter choice can be a more critical step to avoid screw fracture than recycling decision.

  17. Nasal chondrocyte-based engineered autologous cartilage tissue for repair of articular cartilage defects: an observational first-in-human trial.

    Science.gov (United States)

    Mumme, Marcus; Barbero, Andrea; Miot, Sylvie; Wixmerten, Anke; Feliciano, Sandra; Wolf, Francine; Asnaghi, Adelaide M; Baumhoer, Daniel; Bieri, Oliver; Kretzschmar, Martin; Pagenstert, Geert; Haug, Martin; Schaefer, Dirk J; Martin, Ivan; Jakob, Marcel

    2016-10-22

    Articular cartilage injuries have poor repair capacity, leading to progressive joint damage, and cannot be restored predictably by either conventional treatments or advanced therapies based on implantation of articular chondrocytes. Compared with articular chondrocytes, chondrocytes derived from the nasal septum have superior and more reproducible capacity to generate hyaline-like cartilage tissues, with the plasticity to adapt to a joint environment. We aimed to assess whether engineered autologous nasal chondrocyte-based cartilage grafts allow safe and functional restoration of knee cartilage defects. In a first-in-human trial, ten patients with symptomatic, post-traumatic, full-thickness cartilage lesions (2-6 cm 2 ) on the femoral condyle or trochlea were treated at University Hospital Basel in Switzerland. Chondrocytes isolated from a 6 mm nasal septum biopsy specimen were expanded and cultured onto collagen membranes to engineer cartilage grafts (30 × 40 × 2 mm). The engineered tissues were implanted into the femoral defects via mini-arthrotomy and assessed up to 24 months after surgery. Primary outcomes were feasibility and safety of the procedure. Secondary outcomes included self-assessed clinical scores and MRI-based estimation of morphological and compositional quality of the repair tissue. This study is registered with ClinicalTrials.gov, number NCT01605201. The study is ongoing, with an approved extension to 25 patients. For every patient, it was feasible to manufacture cartilaginous grafts with nasal chondrocytes embedded in an extracellular matrix rich in glycosaminoglycan and type II collagen. Engineered tissues were stable through handling with forceps and could be secured in the injured joints. No adverse reactions were recorded and self-assessed clinical scores for pain, knee function, and quality of life were improved significantly from before surgery to 24 months after surgery. Radiological assessments indicated variable degrees of

  18. Manufacturing models permitting roll out/scale out of clinically led autologous cell therapies: regulatory and scientific challenges for comparability.

    Science.gov (United States)

    Hourd, Paul; Ginty, Patrick; Chandra, Amit; Williams, David J

    2014-08-01

    Manufacturing of more-than-minimally manipulated autologous cell therapies presents a number of unique challenges driven by complex supply logistics and the need to scale out production to multiple manufacturing sites or near the patient within hospital settings. The existing regulatory structure in Europe and the United States imposes a requirement to establish and maintain comparability between sites. Under a single market authorization, this is likely to become an unsurmountable burden beyond two or three sites. Unless alternative manufacturing approaches can be found to bridge the regulatory challenge of comparability, realizing a sustainable and investable business model for affordable autologous cell therapy supply is likely to be extremely demanding. Without a proactive approach by the regulators to close this "translational gap," these products may not progress down the development pipeline, threatening patient accessibility to an increasing number of clinician-led autologous cellular therapies that are already demonstrating patient benefits. We propose three prospective manufacturing models for the scale out/roll out of more-than-minimally manipulated clinically led autologous cell therapy products and test their prospects for addressing the challenge of product comparability with a selected expert reference panel of US and UK thought leaders. This paper presents the perspectives and insights of the panel and identifies where operational, technological and scientific improvements should be prioritized. The main purpose of this report is to solicit feedback and seek input from key stakeholders active in the field of autologous cell therapy in establishing a consensus-based manufacturing approach that may permit the roll out of clinically led autologous cell therapies. Copyright © 2014 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  19. Magnet-Sleeve-Sealed Mini Trochoidal-Gear Pump Prototype with Polymer Composite Gear

    Directory of Open Access Journals (Sweden)

    Pedro Javier Gamez-Montero

    2017-09-01

    Full Text Available The trochoidal-gear technology has been growing in groundbreaking fields. Forthcoming applications are demanding to this technology a step forward in the conceiving stage of positive displacement machines. The compendium of the qualities and the inherent characteristics of trochoidal-gear technology, especially towards the gerotor pump, together with scale/size factor and magnetic-driven transmission has led to the idea of a magnet-sleeve-sealed variable flow mini trochoidal-gear pump. From its original concept, to the last phase of the design development, the proof of concept, this new product will intend to overcome problems such as noise, vibration, maintenance, materials, and dimensions. The paper aims to show the technological path followed from the concept, design, and model, to the manufacture of the first prototype, where the theoretical and numerical approaches are not always directly reflected in the prototype performance results. Early in the design process, from a standard-commercial sintered metal mini trochoidal-gear unit, fundamental characteristics and dimensional limitations have been evaluated becoming the strategic parameters that led to its configuration. The main technical challenge to confront is being sealed with non-exterior driveshaft, ensuring that the whole interior is filled and wetted with working fluid and helping the hydrodynamic film formation, the pumping effect, and the heat dissipation. Subsequently, the mini pump architecture, embodiment, methodology, materials, and manufacture are presented. The trend of applications of polymer composite materials and their benefits wanted to be examined with this new mini pump prototype, and a pure polyoxymethylene mini trochoidal-gear set has been designed and manufactured. Finally, both the sintered and the polymer trochoidal-gear units have been experimentally tested in an in-house full-instrumented mini test bench. Although the main goal of the presented work is the

  20. Sudden unilateral visual loss after autologous fat injection into the nasolabial fold

    Directory of Open Access Journals (Sweden)

    Sang Hyouk Park

    2008-10-01

    Full Text Available Sang Hyouk Park, Hae Jung Sun, Kyung Seek ChoiDepartment of ophthalmology, Soonchunhyang University College of Medicine, Seoul, KoreaAbstract: A 27-year-old female presented with sudden visual loss of her right eye after receiving an autologous fat injection into the right nasolabial fold. Fundus examination of the right eye showed multiple whitish patchy lesions with macular edema. Fluorescein angiogram showed deterioration of choroidal circulation with patchy choroidal filling and arm-to-retina circulation time and retinal arteriovenous passage time were delayed to 30 seconds and 20 seconds, respectively. There was no response in flash visual evoked potential (VEP. High dose steroid therapy (methylprednisolone 1 g/day/i.v. was done and about 2 weeks later, the disc edema subsided and retinal arteriovenous passage time of fluorescein angiogram was normalized but there was no improvement in visual acuity. Absence of a cherry red spot, deterioration of choroidal circulation with patchy choroidal fillings seen in fluorescein angiogram, and no response in flash VEP suggests multiple choroidal infarction due to perfusion defect of the short posterior ciliary artery. The autologous fat injected is thought to have entered the dorsal nasal artery and the retrograde migration of the emboli to the ophthalmic artery might have caused the multiple occlusions of the short posterior ciliary artery.Keywords: autologous fat injection, ciliary artery occlusion, ischemic optic neuropathy

  1. Specifically activated memory T cell subsets from cancer patients recognize and reject xenotransplanted autologous tumors

    Science.gov (United States)

    Beckhove, Philipp; Feuerer, Markus; Dolenc, Mathias; Schuetz, Florian; Choi, Carmen; Sommerfeldt, Nora; Schwendemann, Jochen; Ehlert, Katrin; Altevogt, Peter; Bastert, Gunther; Schirrmacher, Volker; Umansky, Viktor

    2004-01-01

    Bone marrow of breast cancer patients was found to contain CD8+ T cells specific for peptides derived from breast cancer–associated proteins MUC1 and Her-2/neu. Most of these cells had a central or effector memory phenotype (CD45RA–CD62L+ or CD45RA–CD62L–, respectively). To test their in vivo function, we separated bone marrow–derived CD45RA+ naive or CD45RA–CD45RO+ memory T cells, stimulated them with autologous dendritic cells pulsed with tumor lysate, and transferred them into NOD/SCID mice bearing autologous breast tumors and normal skin transplants. CD45RA– memory but not CD45RA+ naive T cells infiltrated autologous tumor but not skin tissues after the transfer. These tumor-infiltrating cells had a central or effector memory phenotype and produced perforin. Many of them expressed the P-selectin glycoprotein ligand 1 and were found around P-selectin+ tumor endothelium. Tumor infiltration included cluster formation in tumor tissue by memory T cells with cotransferred dendritic cells. It was associated with the induction of tumor cell apoptosis and significant tumor reduction. We thus demonstrate selective homing of memory T cells to human tumors and suggest that tumor rejection is based on the recognition of tumor-associated antigens on tumor cells and dendritic cells by autologous specifically activated central and effector memory T cells. PMID:15232613

  2. From Punched Cards to "Big Data": A Social History of Database Populism

    Directory of Open Access Journals (Sweden)

    Kevin Driscoll

    2012-08-01

    Full Text Available Since the diffusion of the punched card tabulator following the 1890 U.S. Census, mass-scale information processing has been alternately a site of opportunity, ambivalence and fear in the American imagination. While large bureaucracies have tended to deploy database technology toward purposes of surveillance and control, the rise of personal computing made databases accessible to individuals and small businesses for the first time. Today, the massive collection of trace communication data by public and private institutions has renewed popular anxiety about the role of the database in society. This essay traces the social history of database technology across three periods that represent significant changes in the accessibility and infrastructure of information processing systems. Although many proposed uses of "big data" seem to threaten individual privacy, a largely-forgotten database populism from the 1970s and 1980s suggests that a reclamation of small-scale data processing might lead to sharper popular critique in the future.

  3. Action of topical mometasone on the pigmented halos of micrografting in patients with vitiligo Ação da mometasona tópica nos halos pigmentares de microenxertia em vitiligo

    Directory of Open Access Journals (Sweden)

    Karine Dantas Diógenes Saldanha

    2012-10-01

    Full Text Available BACKGROUND: Vitiligo is a prevalent skin pigmentation disorder worldwide. The treatments available still offer limited results to some patients. For patients with clinically stable vitiligo, melanocyte transplantation is an appropriate treatment option, and the technique of autologous punch grafting shows good repigmentation. OBJECTIVE: To evaluate the effect of topical mometasone on the halos of repigmentation after autologous punch grafting in patients with clinically stable vitiligo. METHODS: Between 2009 and 2010, 11 patients with clinically stable vitiligo (7 generalized, 2 focal and 2 segmental underwent autologous punch grafting in the achromic patches. According to the clinical type of vitiligo, patients were instructed to use the corticosteroid ointment during 6 months, only on a few grafted lesions. In the first month, the mometasone ointment was used twice a day and after that just once. They were reassessed 1, 3 and 6 months after the procedure. Grafted halos were photographed and recorded using the software fotofinder. After 6 months, all the treated and untreated areas of the repigmentation halos were measured and analyzed comparatively. RESULTS: The median area of the repigmentation halos after 6 months of treatment with mometasone was larger (25,96 mm² than the one of the untreated halos (13,86 mm² , showing a statistically significant difference (p = 0,026. CONCLUSION: In this study, the use of mometasone ointment increased the area of the repigmentation halos after punch grafting. However, this should be further investigated in larger samples in order to validate this positive action in the treatment of stable vitiligo.FUNDAMENTOS: Vitiligo é um transtorno de pigmentação freqüente na população mundial. Seu tratamento ainda oferece resultados limitados em alguns pacientes. Nos casos de vitiligo estável clinicamente, o transplante de melanócitos tornase uma opção terapêutica, sendo a técnica de enxertos aut

  4. Gastrocnemius tendon strain in a dog treated with autologous mesenchymal stem cells and a custom orthosis.

    Science.gov (United States)

    Case, J Brad; Palmer, Ross; Valdes-Martinez, Alex; Egger, Erick L; Haussler, Kevin K

    2013-05-01

    To report clinical findings and outcome in a dog with gastrocnemius tendon strain treated with autologous mesenchymal stem cells and a custom orthosis. Clinical report. A 4-year-old spayed female Border Collie. Bone-marrow derived, autologous mesenchymal stem cells were transplanted into the tendon core lesion. A custom, progressive, dynamic orthosis was fit to the tarsus. Serial orthopedic examinations and ultrasonography as well as long-term force-plate gait analysis were utilized for follow up. Lameness subjectively resolved and peak vertical force increased from 43% to 92% of the contralateral pelvic limb. Serial ultrasonographic examinations revealed improved but incomplete restoration of normal linear fiber pattern of the gastrocnemius tendon. Findings suggest that autologous mesenchymal stem cell transplantation with custom, progressive, dynamic orthosis may be a viable, minimally invasive technique for treatment of calcaneal tendon injuries in dogs. © Copyright 2013 by The American College of Veterinary Surgeons.

  5. Surgical management of fractured orthodontic mini- implant- a case report.

    Science.gov (United States)

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  6. Indications and organisational methods for autologous blood transfusion procedures in Italy: results of a national survey.

    Science.gov (United States)

    Catalano, Liviana; Campolongo, Alessandra; Caponera, Maurizio; Berzuini, Alessandra; Bontadini, Andrea; Furlò, Giuseppe; Pasqualetti, Patrizio; Liumbruno, Giancarlo M

    2014-10-01

    Pre-operative donation of autologous blood is a practice that is now being abandoned. Alternative methods of transfusing autologous blood, other than predeposited blood, do however play a role in limiting the need for transfusion of allogeneic blood. This survey of autologous blood transfusion practices, promoted by the Italian Society of Transfusion Medicine and Immunohaematology more than 2 years after the publication of national recommendations on the subject, was intended to acquire information on the indications for predeposit in Italy and on some organisational aspects of the alternative techniques of autotransfusion. A structured questionnaire consisting of 22 questions on the indications and organisational methods of autologous blood transfusion was made available on a web platform from 15 January to 15 March, 2013. The 232 Transfusion Services in Italy were invited by e-mail to complete the online survey. Of the 232 transfusion structures contacted, 160 (69%) responded to the survey, with the response rate decreasing from the North towards the South and the Islands. The use of predeposit has decreased considerably in Italy and about 50% of the units collected are discarded because of lack of use. Alternative techniques (acute isovolaemic haemodilution and peri-operative blood salvage) are used at different frequencies across the country. The data collected in this survey can be considered representative of national practice; they show that the already very limited indications for predeposit autologous blood transfusion must be adhered to even more scrupulously, also to avoid the notable waste of resources due to unused units.Users of alternative autotransfusion techniques must be involved in order to gain a full picture of the degree of use of such techniques; multidisciplinary agreement on the indications for their use is essential in order for these indications to have an effective role in "patient blood management" programmes.

  7. Validation of an electronic version of the Mini Asthma Quality of Life Questionnaire.

    Science.gov (United States)

    Olajos-Clow, J; Minard, J; Szpiro, K; Juniper, E F; Turcotte, S; Jiang, X; Jenkins, B; Lougheed, M D

    2010-05-01

    The Mini Asthma Quality of Life Questionnaire (MiniAQLQ) is a validated disease-specific quality of life (QOL) paper (p) questionnaire. Electronic (e) versions enable inclusion of asthma QOL in electronic medical records and research databases. To validate an e-version of the MiniAQLQ, compare time required for completion of e- and p-versions, and determine which version participants prefer. Adults with stable asthma were randomized to complete either the e- or p-MiniAQLQ, followed by a 2-h rest period before completing the other version. Agreement between versions was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Two participants with incomplete p-MiniAQLQ responses were excluded. Forty participants (85% female; age 47.7 +/- 14.9 years; asthma duration 22.6 +/- 16.1 years; FEV(1) 87.1 +/- 21.6% predicted) with both AQLQ scores limitation, emotional function and environmental stimuli domains were 0.94, 0.89, 0.90, and 0.91 respectively. A small but significant bias (Delta=0.3; P=0.004) was noted in the activity limitation domain. Completion time was significantly longer for the e-version (3.8 +/- 1.9min versus 2.7 +/- 1.1min; Ppreferred the e-MiniAQLQ; 35% had no preference. This e-version of the MiniAQLQ is valid and was preferred by most participants despite taking slightly longer to complete. Generalizabilty may be limited in younger (12-17) and older (>65) adults.

  8. 煤层底板穿层钻孔水力冲孔技术的应用及效果考察%Coal Floor Layer of Drilling Hydraulic Punching Technology Application and Effect of Investigation

    Institute of Scientific and Technical Information of China (English)

    殷庆超; 廉有轩; 王恩营; 刘度

    2015-01-01

    End of the alley pumping wear layer drilling hydraulic punching pressure, the anti-reflection measures can effectively en-hance the permeability of coal seam, expanding radius of extraction and improve the effect of the gas extraction., on the basis of the principle of antireflection unloading hydraulic punching in for zhengzhou mining revitalization of two coal mine hydraulic punching plate wear layer, gas drainage concentration before and after the hydraulic punching, the change of coal seam permeability and the gas flow attenuation coefficient and so on.The test results show that the average single-hole gas drainage concentration is 11.02%, after hy-draulic punching is 2.14%, the anti-reflection measures of improve 4 times; Coefficient of permeability of coal seam after taking steps to improve the 39 times;The gas flow attenuation coefficient is reduced nearly 3 times.Using the method of pressure measured at the same time the mine hydraulic punching effective drainage radius to 10 m.%采用底抽巷穿层钻孔水力冲孔卸压增透措施,可以有效增强煤层的透气性、扩大抽采半径和提高瓦斯抽采效果。基于水力冲孔卸压增透原理,对郑州矿区振兴二矿突出煤层实施底板穿层水力冲孔,考察水力冲孔前后瓦斯抽放浓度、煤层透气性和瓦斯流量衰减系数等的变化。试验结果表明:单孔平均瓦斯抽放浓度在水力冲孔后为11.02%,较未采取增透措施时的2.14%,提高了4倍;煤层透气性系数在采取措施后提高了39倍;瓦斯流量衰减系数则减小了近3倍。同时运用压力法测得该矿水力冲孔有效抽放半径为10 m。

  9. Infusion of Autologous Retrodifferentiated Stem Cells into Patients with Beta-Thalassemia

    Directory of Open Access Journals (Sweden)

    Ilham Saleh Abuljadayel

    2006-01-01

    Full Text Available Beta-thalassemia is a genetic, red blood cell disorder affecting the beta-globin chain of the adult hemoglobin gene. This results in excess accumulation of unpaired alpha-chain gene products leading to reduced red blood cell life span and the development of severe anemia. Current treatment of this disease involves regular blood transfusion and adjunct chelation therapy to lower blood transfusion–induced iron overload. Fetal hemoglobin switching agents have been proposed to treat genetic blood disorders, such as sickle cell anemia and beta-thalassemia, in an effort to compensate for the dysfunctional form of the beta-globin chain in adult hemoglobin. The rationale behind this approach is to pair the excess normal alpha-globin chain with the alternative fetal gamma-chain to promote red blood cell survival and ameliorate the anemia. Reprogramming of differentiation in intact, mature, adult white blood cells in response to inclusion of monoclonal antibody CR3/43 has been described. This form of retrograde development has been termed “retrodifferentiation”, with the ability to re-express a variety of stem cell markers in a heterogeneous population of white blood cells. This form of reprogramming, or reontogeny, to a more pluripotent stem cell state ought to recapitulate early hematopoiesis and facilitate expression of a fetal and/or adult program of hemoglobin synthesis or regeneration on infusion and subsequent redifferentiation. Herein, the outcome of infusion of autologous retrodifferentiated stem cells (RSC into 21 patients with beta-thalassemia is described. Over 6 months, Infusion of 3-h autologous RSC subjected to hematopoietic-conducive conditions into patients with beta-thalassemia reduced mean blood transfusion requirement, increased mean fetal hemoglobin synthesis, and significantly lowered mean serum ferritin. This was always accompanied by an increase in mean corpuscular volume (MCV, mean corpuscular hemoglobin (MCH, and mean

  10. "Mini", "Midi" and the Student.

    Science.gov (United States)

    Edwards, Perry; Broadwell, Bruce

    Mini- and midi-computers have been introduced into the computer science program at Sierra College to afford students more direct contact with computers. The college's administration combined with the Science and Business departments to share the expense and utilization of the program. The National Cash Register Century 100 and the Data General…

  11. Cartilage repair: Generations of autologous chondrocyte transplantation

    International Nuclear Information System (INIS)

    Marlovits, Stefan; Zeller, Philip; Singer, Philipp; Resinger, Christoph; Vecsei, Vilmos

    2006-01-01

    Articular cartilage in adults has a limited capacity for self-repair after a substantial injury. Surgical therapeutic efforts to treat cartilage defects have focused on delivering new cells capable of chondrogenesis into the lesions. Autologous chondrocyte transplantation (ACT) is an advanced cell-based orthobiologic technology used for the treatment of chondral defects of the knee that has been in clinical use since 1987 and has been performed on 12,000 patients internationally. With ACT, good to excellent clinical results are seen in isolated post-traumatic lesions of the knee joint in the younger patient, with the formation of hyaline or hyaline-like repair tissue. In the classic ACT technique, chondrocytes are isolated from small slices of cartilage harvested arthroscopically from a minor weight-bearing area of the injured knee. The extracellular matrix is removed by enzymatic digestion, and the cells are then expanded in monolayer culture. Once a sufficient number of cells has been obtained, the chondrocytes are implanted into the cartilage defect, using a periosteal patch over the defect as a method of cell containment. The major complications are periosteal hypertrophy, delamination of the transplant, arthrofibrosis and transplant failure. Further improvements in tissue engineering have contributed to the next generation of ACT techniques, where cells are combined with resorbable biomaterials, as in matrix-associated autologous chondrocyte transplantation (MACT). These biomaterials secure the cells in the defect area and enhance their proliferation and differentiation

  12. Cartilage repair: Generations of autologous chondrocyte transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Marlovits, Stefan [Department of Traumatology, Center for Joint and Cartilage, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)]. E-mail: stefan.marlovits@meduniwien.ac.at; Zeller, Philip [Department of Traumatology, Center for Joint and Cartilage, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Singer, Philipp [Department of Traumatology, Center for Joint and Cartilage, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Resinger, Christoph [Department of Traumatology, Center for Joint and Cartilage, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Vecsei, Vilmos [Department of Traumatology, Center for Joint and Cartilage, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2006-01-15

    Articular cartilage in adults has a limited capacity for self-repair after a substantial injury. Surgical therapeutic efforts to treat cartilage defects have focused on delivering new cells capable of chondrogenesis into the lesions. Autologous chondrocyte transplantation (ACT) is an advanced cell-based orthobiologic technology used for the treatment of chondral defects of the knee that has been in clinical use since 1987 and has been performed on 12,000 patients internationally. With ACT, good to excellent clinical results are seen in isolated post-traumatic lesions of the knee joint in the younger patient, with the formation of hyaline or hyaline-like repair tissue. In the classic ACT technique, chondrocytes are isolated from small slices of cartilage harvested arthroscopically from a minor weight-bearing area of the injured knee. The extracellular matrix is removed by enzymatic digestion, and the cells are then expanded in monolayer culture. Once a sufficient number of cells has been obtained, the chondrocytes are implanted into the cartilage defect, using a periosteal patch over the defect as a method of cell containment. The major complications are periosteal hypertrophy, delamination of the transplant, arthrofibrosis and transplant failure. Further improvements in tissue engineering have contributed to the next generation of ACT techniques, where cells are combined with resorbable biomaterials, as in matrix-associated autologous chondrocyte transplantation (MACT). These biomaterials secure the cells in the defect area and enhance their proliferation and differentiation.

  13. Intrathecal application of autologous bone marrow cell preparations in parkinsonian syndromes

    DEFF Research Database (Denmark)

    Storch, Alexander; Csoti, Ilona; Eggert, Karla

    2012-01-01

    A growing number of patients is treated with intrathecal application of autologous bone marrow cells (aBMCs), but clinical data are completely lacking in movement disorders. We provide first clinical data on efficacy and safety of this highly experimental treatment approach in parkinsonian...

  14. AFM Colloidal Probe Measurements Implicate Capillary Condensation in Punch-Particle Surface Interactions during Tableting.

    Science.gov (United States)

    Badal Tejedor, Maria; Nordgren, Niklas; Schuleit, Michael; Millqvist-Fureby, Anna; Rutland, Mark W

    2017-11-21

    Adhesion of the powders to the punches is a common issue during tableting. This phenomenon is known as sticking and affects the quality of the manufactured tablets. Defective tablets increase the cost of the manufacturing process. Thus, the ability to predict the tableting performance of the formulation blend before the process is scaled-up is important. The adhesive propensity of the powder to the tableting tools is mostly governed by the surface-surface adhesive interactions. Atomic force microscopy (AFM) colloidal probe is a surface characterization technique that allows the measurement of the adhesive interactions between two materials of interest. In this study, AFM steel colloidal probe measurements were performed on ibuprofen, MCC (microcrystalline cellulose), α-lactose monohydrate, and spray-dried lactose particles as an approach to modeling the punch-particle surface interactions during tableting. The excipients (lactose and MCC) showed constant, small, attractive, and adhesive forces toward the steel surface after a repeated number of contacts. In comparison, ibuprofen displayed a much larger attractive and adhesive interaction increasing over time both in magnitude and in jump-in/jump-out separation distance. The type of interaction acting on the excipient-steel interface can be related to a van der Waals force, which is relatively weak and short-ranged. By contrast, the ibuprofen-steel interaction is described by a capillary force profile. Even though ibuprofen is not highly hydrophilic, the relatively smooth surfaces of the crystals allow "contact flooding" upon contact with the steel probe. Capillary forces increase because of the "harvesting" of moisture-due to the fast condensation kinetics-leaving a residual condensate that contributes to increase the interaction force after each consecutive contact. Local asperity contacts on the more hydrophilic surface of the excipients prevent the flooding of the contact zone, and there is no such adhesive

  15. Injection Pharyngoplasty With Autologous Fat as Treatment for Stress Velopharyngeal Insufficiency in Brass and Woodwind Musicians.

    Science.gov (United States)

    Syamal, Mausumi N; Bryson, Paul C

    2017-02-01

    Stress velopharyngeal insufficiency (SVPI) is an uncommon but often career-threatening condition affecting professional brass and woodwind musicians. To review the evaluation of and treatment for SVPI in professional musicians with lipoinjection to the posterior pharyngeal wall. A retrospective medical record and literature review. Two professional musicians with SVPI treated with autologous lipoinjection to the posterior pharyngeal wall were included. Nasopharyngoscopy was performed while patients played their instrument both before and after injection. To assess the effectiveness of autologous fat injection to the posterior pharyngeal wall to treat stress velopharyngeal insufficiency in 2 professional instrumentalists. Successful treatment was the absence of VPI during playing as visualized by flexible nasopharyngoscopy. After autologous lipoinjection of the posterior pharyngeal wall, 1 patient resumed full play with complete resolution, now 3 years after lipoinjection pharyngoplasty. The other patient received temporary resolution. Both had no surgical complications. Stress VPI is often a career-threatening condition for professional brass and woodwind musicians, with a cited incidence of 34%. Various treatment options in the literature include observation, speech and language pathology referral for pharyngeal strengthening, lipoinjection of the soft palate, and more invasive options, such as sphincter pharyngoplasty, pharyngeal flaps and V-Y pushback. Autologous fat injection pharyngoplasty of the posterior pharyngeal wall may be a less invasive treatment option for musicians with SVPI.

  16. Nanofat-derived stem cells with platelet-rich fibrin improve facial contour remodeling and skin rejuvenation after autologous structural fat transplantation

    Science.gov (United States)

    Liang, Zhi-Jie; Chen, Hai; Zhu, Mao-Guang; Xu, Fang-Tian; He, Ning; Wei, Xiao-Juan; Li, Hong-Mian

    2017-01-01

    Traditional autologous fat transplantation is a common surgical procedure for treating facial soft tissue depression and skin aging. However, the transplanted fat is easily absorbed, reducing the long-term efficacy of the procedure. Here, we examined the efficacy of nanofat-assisted autologous fat structural transplantation. Nanofat-derived stem cells (NFSCs) were isolated, mechanically emulsified, cultured, and characterized. Platelet-rich fibrin (PRF) enhanced proliferation and adipogenic differentiation of NFSCs in vitro. We then compared 62 test group patients with soft tissue depression or signs of aging who underwent combined nanofat, PRF, and autologous fat structural transplantation to control patients (77 cases) who underwent traditional autologous fat transplantation. Facial soft tissue depression symptoms and skin texture were improved to a greater extent after nanofat transplants than after traditional transplants, and the nanofat group had an overall satisfaction rate above 90%. These data suggest that NFSCs function similarly to mesenchymal stem cells and share many of the biological characteristics of traditional fat stem cell cultures. Transplants that combine newly-isolated nanofat, which has a rich stromal vascular fraction (SVF), with PRF and autologous structural fat granules may therefore be a safe, highly-effective, and long-lasting method for remodeling facial contours and rejuvenating the skin. PMID:28978136

  17. Mini International Neuropsychiatric Interview (MINI): validação de entrevista breve para diagnóstico de transtornos mentais

    OpenAIRE

    Amorim, Patrícia

    2000-01-01

    Objetivos: O MINI é uma entrevista diagnóstica padronizada breve (15-30 minutos), compatível com os critérios do DSM-III-R/IV e da CID-10, que é destinada à utilização na prática clínica e na pesquisa em atenção primária e em psiquiatria, e pode ser utilizada por clínicos após um treinamento rápido (de 1 a 3 horas). A versão Plus do MINI, mais detalhada, gera diagnósticos positivos dos principais transtornos psicóticos e do humor do DSM-IV. Este artigo apresenta os resultados de quatro estudo...

  18. [Human herpesvirus-6 pneumonitis following autologous peripheral blood stem cell transplantation].

    Science.gov (United States)

    Saitoh, Yuu; Gotoh, Moritaka; Yoshizawa, Seiichiro; Akahane, Daigo; Fujimoto, Hiroaki; Ito, Yoshikazu; Ohyashiki, Kazuma

    2018-01-01

    A-46-year-old man was diagnosed with peripheral T cell lymphoma, not otherwise specified. He achieved a complete remission after pirarubicin, cyclophosphamide, vincristine, and prednisolone (THP-COP) therapy and successful autologous peripheral blood stem-cell transplantation (AutoSCT). However, 6 months post AutoSCT, he complained of fever. Chest computed tomography of the patient displayed bilateral interstitial pneumonitis. Human herpesvirus-6 (HHV-6) DNA was detected in his bronchoalveolar lavage fluid. Therefore, the patient was confirmed for HHV-6 pneumonitis. The treatment with foscarnet was effective, and no relapse was noticed in the patient. Besides, we have experienced pneumonitis of unknown origin in some patients after autologous or allogeneic stem-cell transplantations. Moreover, most of the above patients were clinically diagnosed using serum or plasma markers. Therefore, examining respiratory symptoms after AutoSCT would enable a more accurate diagnosis as well as treatment of patients with HHV-6 pneumonitis.

  19. Mandibular Overdentures Retained by Two Mini-Implants: A Seven-Year Retention and Satisfaction Study.

    Science.gov (United States)

    Catalán, Alfonso; Martínez, Alejandra; Marchesani, Francisco; González, Urcesino

    2016-07-01

    Patients with atrophic edentulous ridges generally have problems with retention, therapeutic satisfaction, and comfort with their complete dentures. An alternative treatment to assist in improving retention and stability involves the use of mini-implants. The aim of this study was to evaluate the retention of mandibular overdentures connected to two mini-implants and overall patient satisfaction with them. Seven patients with atrophic mandibular ridges (Type 4D Misch classification), aged 62 to 74 years old were rehabilitated with complete dentures. In each patient, two mini-implants measuring 15 or 13 mm in length and 1.8 mm in diameter were placed. After 15 days, overdentures were connected to the mini-implants with O-ring attachments. In each patient, retention of the overdentures was measured, and a survey of therapeutic satisfaction before and after connection to the mini-implants was administered. Prosthesis retention was measured with a digital dynamometer at 1 month, 6 months, and 2, 3, 5, and 7 years after mini-implant placement. Patient satisfaction was assessed with a survey. Data were analyzed with Student's t-test (satisfaction survey) and the Friedman test (retention measurements and satisfaction survey). The initial retention values (0.34 to 0.63 N without mini-implants) varied significantly (p ≤ 0.050). These values were less than the subsequent measurements of 3.92 to 9.64 N, taken after placement of the mini-implants and connecting them to the dentures. Satisfaction was good to very good over the 7-year observation period. Mucosa and peri-implant bone showed no pathological changes. In this limited sample size clinical study the results indicated that after connecting mandibular overdentures to two mini-implants, patient satisfaction significantly increased and retention significantly improved during the 7-year observation period. © 2015 by the American College of Prosthodontists.

  20. Hodgkin's disease as unusual presentation of post-transplant lymphoproliferative disorder after autologous hematopoietic cell transplantation for malignant glioma

    Directory of Open Access Journals (Sweden)

    Scelsi Mario

    2005-08-01

    Full Text Available Abstract Background Post-transplant lymphoproliferative disorder (PTLD is a complication of solid organ and allogeneic hematopoietic stem cell transplantation (HSCT; following autologous HSCT only rare cases of PTLD have been reported. Here, a case of Hodgkin's disease (HD, as unusual presentation of PTLD after autologous HSCT for malignant glioma is described. Case presentation 60-years old man affected by cerebral anaplastic astrocytoma underwent subtotal neurosurgical excision and subsequent high-dose chemotherapy followed by autologous HSCT. During the post HSCT course, cranial irradiation and corticosteroids were administered as completion of therapeutic program. At day +105 after HSCT, the patient developed HD, nodular sclerosis type, with polymorphic HD-like skin infiltration. Conclusion The clinical and pathological findings were consistent with the diagnosis of PTLD.