WorldWideScience

Sample records for artificial vein system

  1. Vein matching using artificial neural network in vein authentication systems

    Science.gov (United States)

    Noori Hoshyar, Azadeh; Sulaiman, Riza

    2011-10-01

    Personal identification technology as security systems is developing rapidly. Traditional authentication modes like key; password; card are not safe enough because they could be stolen or easily forgotten. Biometric as developed technology has been applied to a wide range of systems. According to different researchers, vein biometric is a good candidate among other biometric traits such as fingerprint, hand geometry, voice, DNA and etc for authentication systems. Vein authentication systems can be designed by different methodologies. All the methodologies consist of matching stage which is too important for final verification of the system. Neural Network is an effective methodology for matching and recognizing individuals in authentication systems. Therefore, this paper explains and implements the Neural Network methodology for finger vein authentication system. Neural Network is trained in Matlab to match the vein features of authentication system. The Network simulation shows the quality of matching as 95% which is a good performance for authentication system matching.

  2. Anatomic variation of the deep venous system and its relationship with deep vein thrombosis found on the lower extremity venograms that were obtained after artificial joint replacements

    International Nuclear Information System (INIS)

    Lee, Min Sun; Lee, Jee Eun; Hwang, Ji Young; Shim, Sung Shine; Yoo, Jeong Hyun; Suh, Jeong Soo; Park, Jae Young

    2006-01-01

    We wanted to evaluate the anatomic variations, the number of valves and the presence of deep vein thrombosis (DVT) on the lower extremity venograms obtained after artificial joint replacements, and we also wanted to determine the correlation of the incidence of DVT with the above-mentioned factors and the operation sites. From January to June 2004, conventional ascending contrast venographies of the lower extremities were performed in 119 patients at 7-10 days after artificial joint replacement, and all the patients were asymptomatic. Total knee replacement was done for 152 cases and total hip replacement was done for 34 cases. On all the venographic images of 186 limbs, the anatomic variations were classified and the presence of DVT was evaluated; the number of valves in the superficial femoral vein (SFV) and calf veins was counted. The sites of DVT were classified as calf, thigh and pelvis. Statistically, chi square tests and Fischer's exact tests were performed to determine the correlation of the incidence of DVT with the anatomic variations, the numbers of valves and the operation sites. Theoretically, there are 9 types of anatomical variation in the deep vein system of the lower extremity that can be classified, but only 7 types were observed in this study. The most frequent type was the normal single SFV type and this was noted in 117 cases (63%), and the others were all variations (69 cases, 37%). There was a 22.2% incidence of DVT (69 cases) in the normal single SFV type and 26.4% (17 cases) in the other variations. No significant difference was noted in the incidences of DVT between the two groups. In addition, no significant statistical differences were noted for the incidences of DVT between the single or variant multiple veins in the SFV and the popliteal vein (PV) respectively, between the different groups with small or large numbers of valves in the thigh and calf, respectively, and also between the different operation sites of the hip or knee

  3. Case report of deep vein thrombosis caused by artificial urinary sphincter reservoir compressing right external iliac vein

    Directory of Open Access Journals (Sweden)

    Marcus J Yip

    2015-01-01

    Full Text Available Artificial urinary sphincters (AUSs are commonly used after radical prostatectomy for those who are incontinent of urine. However, they are associated with complications, the most common being reservoir uprising or migration. We present a unique case of occlusive external iliac and femoral vein obstruction by the AUS reservoir causing thrombosis. Deflation of the reservoir and anticoagulation has, thus far, not been successful at decreasing thrombus burden. We present this case as a rare, but significant surgical complication; explore the risk factors that may have contributed, and other potential endovascular therapies to address this previously unreported AUS complication.

  4. Fabrication of subcutaneous veins phantom for vessel visualization system

    Science.gov (United States)

    Cheng, Kai; Narita, Kazuyuki; Morita, Yusuke; Nakamachi, Eiji; Honda, Norihiro; Awazu, Kunio

    2013-09-01

    The technique of subcutaneous veins imaging by using NIR (Near Infrared Radiation) is widely used in medical applications, such as the intravenous injection and the blood sampling. In the previous study, an automatic 3D blood vessel search and automatic blood sampling system was newly developed. In order to validate this NIR imaging system, we adopted the subcutaneous vein in the human arm and its artificial phantom, which imitate the human fat and blood vessel. The human skin and subcutaneous vein is characterized as the uncertainty object, which has the individual specificity, non-accurate depth information, non-steady state and hardly to be fixed in the examination apparatus. On the other hand, the conventional phantom was quite distinct from the human's characteristics, such as the non-multilayer structure, disagreement of optical property. In this study, we develop a multilayer phantom, which is quite similar with human skin, for improvement of NIR detection system evaluation. The phantom consists of three layers, such as the epidermis layer, the dermis layer and the subcutaneous fat layer. In subcutaneous fat layer, we built a blood vessel. We use the intralipid to imitate the optical scattering characteristics of human skin, and the hemoglobin and melanin for the optical absorption characteristics. In this study, we did two subjects. First, we decide the fabrication process of the phantom. Second, we compared newly developed phantoms with human skin by using our NIR detecting system, and confirm the availability of these phantoms.

  5. Establishment of extracorporeal circulation of artificial liver support system in high altitude region

    Directory of Open Access Journals (Sweden)

    Ming-sen ZHANG

    2011-01-01

    Full Text Available Objective To establish extracorporeal circulation in big animal suitable for the research on artificial liver support system in high altitude region.Methods Under the anesthesia of ketamine hydrochloride/diazepam IV,cannulation of common carotid artery/external jugular vein(n=3 and inferior vena cava via the left external jugular vein/right external jugular vein(n=3,was respectively performed on six healthy Chang-Bai piglets adapted to native environment(altitude 3700m.One day after that,the extracorporeal circulation was performed at a progressively elevated blood current velocity,and the general condition of the animals,blood pressure,HR,bleeding tendoncy of the experimental pigs and coagulation in the cannulae were observed.Results On the premise that the hemodynamics was not influenced,the highest blood current velocity was 133.33±28.87ml/min,the lowest heparin maintaining speed amounted to 138.67±12.22mg/h,and the bleeding tendency and blood coagulation in the cannula was significant in the group of common carotid artery/external jugular vein intubation.While the highest blood current velocity was 400ml/min,the lowest heparin maintaining speed was 26.67±9.24mg/h,no bleeding tendency or obvious cannular blood coagulation were observed in the group of cannulation of inferior vena cava via the left external jugular vein/right external jugular vein.These untoward results were significantly less or slight than that of the former group(P < 0.01.Conclusion It is suitable to perform research of artificial liver support system on piglets in high altitude region by establishing extracorporeal circulation by the way of inferior vena cava with cannulation passing through the left external jugular vein/right external jugular vein with the blood current velocity of 400ml/min.

  6. Non-contact finger vein acquisition system using NIR laser

    Science.gov (United States)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  7. A Vein Map Biometric System

    Directory of Open Access Journals (Sweden)

    Felix Fuentes

    2013-08-01

    Full Text Available There is increasing demand world-wide, from government agencies and the private sector for cutting-edge biometric security technology that is difficult to breach but userfriendly at the same time. Some of the older tools, such as fingerprint, retina and iris scanning, and facial recognition software have all been found to have flaws and often viewed negatively because of many cultural and hygienic issues associated with them. Comparatively, mapping veins as a human barcode, a new technology, has many advantages over older technologies. Specifically, reproducing a three-dimensional model of a human vein system is impossible to replicate. Vein map technology is distinctive because of its state-of-the-art sensors are only able to recognize vein patterns if hemoglobin is actively flowing through the person

  8. Augmented reality based real-time subcutaneous vein imaging system.

    Science.gov (United States)

    Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian

    2016-07-01

    A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.

  9. Phenotypic heterogeneity in the endothelium of the human vortex vein system.

    Science.gov (United States)

    Yu, Paula K; Tan, Priscilla E Z; Cringle, Stephen J; McAllister, Ian L; Yu, Dao-Yi

    2013-10-01

    The vortex vein system is the drainage pathway for the choroidal circulation and serves an important function in the effective drainage of the exceptionally high blood flow from the choroidal circulation. As there are only 4-6 vortex veins, a large volume of blood must be drained from many choroidal veins into each individual vortex vein. The vortex vein system must also cope with passing through tissues of different rigidity and significant pressure gradient as it transverses from the intrao-cular to the extra-ocular compartments. However, little is known about how the vortex vein system works under such complex situations in both physiological and pathological condition. Endothelial cells play a vital role in other vascular systems, but they have not been studied in detail in the vortex vein system. The purpose of this study is to characterise the intracellular structures and morphology in both the intra-and extra-ocular regions of the human vortex vein system. We hypothesise the presence of endothelial phenotypic heterogeneity through the vortex vein system. The inferior temporal vortex vein system from human donor eyes were obtained and studied histologically using confocal microscopy. The f-actin cytoskeleton and nuclei were labelled using Alexa Fluor conjugated Phalloidin and YO-PRO-1. Eight regions of the vortex vein system were examined with the venous endothelium studied in detail with quantitative data obtained for endothelial cell and nuclei size and shape. Significant endothelial phenotypic heterogeneity was found throughout the vortex vein system with the most obvious differences observed between the ampulla and its downstream regions. Variation in the distribution pattern of smooth muscle cells, in particular the absence of smooth muscle cells around the ampulla, was noted. Our results suggest the presence of significantly different haemodynamic forces in different regions of the vortex vein system and indicate that the vortex vein system may play

  10. Regional heterogeneity of endothelial cells in the porcine vortex vein system.

    Science.gov (United States)

    Tan, Priscilla Ern Zhi; Yu, Paula K; Cringle, Stephen J; Morgan, William H; Yu, Dao-Yi

    2013-09-01

    The aim of this study was to investigate whether region-dependent endothelial heterogeneity is present within the porcine vortex vein system. The superior temporal vortex vein in young adult pig eyes were dissected out and cannulated. The intact vortex vein system down to the choroidal veins was then perfused with labels for f-actin and nucleic acid. The endothelial cells within the choroidal veins, pre-ampulla, anterior portion of the ampulla, mid-ampulla, posterior portion of the ampulla, post-ampulla, intra-scleral canal and the extra-ocular vortex vein regions were studied in detail using a confocal microscopy technique. The endothelial cell and nuclei length, width, area and perimeter were measured and compared between the different regions. Significant regional differences in the endothelial cell and nuclei length, width, area and perimeter were observed throughout the porcine vortex vein system. Most notably, very narrow and elongated endothelia were found in the post-ampulla region. A lack of smooth muscle cells was noted in the ampulla region compared to other regions. Heterogeneity in endothelial cell morphology is present throughout the porcine vortex vein system and there is a lack of smooth muscle cells in the ampulla region. This likely reflects the highly varied haemodynamic conditions and potential blood flow control mechanisms in different regions of the vortex vein system. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Endovascular vein harvest: systemic carbon dioxide absorption.

    Science.gov (United States)

    Maslow, Andrew M; Schwartz, Carl S; Bert, Arthur; Hurlburt, Peter; Gough, Jeffrey; Stearns, Gary; Singh, Arun K

    2006-06-01

    Endovascular vein harvest (EDVH) requires CO(2) insufflation to expand the subcutaneous space, allowing visualization and dissection of the saphenous vein. The purpose of this study was to assess the extent of CO(2) absorption during EDVH. Prospective observational study. Single tertiary care hospital. Sixty patients (30 EDVH and 30 open-vein harvest) undergoing isolated coronary artery bypass graft surgery. Hemodynamic, procedural, and laboratory data were collected prior to (baseline), during, and at it the conclusion (final) of vein harvesting. Data were also collected during cardiopulmonary bypass (CPB). Data were compared by using t tests, analysis of variance, and correlation statistics when needed. There were significant increases in arterial CO(2) (PaCO(2), 35%) and decreases in pH (1.35%) during EDVH. These were associated with increases in heart rate, mean blood pressure, and cardiac output. Within the EDVH group, greater elevations (>10 mmHg) in PaCO2 were more likely during difficult harvest procedures, and these patients exhibited greater increase in heart rate. Elevated CO(2) persisted during CPB, requiring higher systemic gas flows and greater use of phenylephrine to maintain desired hemodynamics. EDVH was associated with systemic absorption of CO(2). Greater absorption was more likely in difficult procedures and was associated with greater hemodynamic changes requiring medical therapy.

  12. Mineralization and hydrothermal alteration of the Tajroud vein system, south of Neyshabour

    Directory of Open Access Journals (Sweden)

    Mohsen Alikhani Banghani

    2013-10-01

    Full Text Available The Tajroud vein system is located 190 km southwest of Mashhad, and in the southern part of the Sabzevar zone. The vein host rocks consist of Eocene intermediate to silicic volcanic rocks. The mineralization occurs as open space filling, taking place as veins, veinlets and hydrothermal breccias. Based on field geology and textural evidence, three main stages of mineralization were identified. Stage I mainly contains quartz, pyrite, chalcopyrite and magnetite. Stage II, which has the same mineral assemblage as stage I, is the most important stage in terms of volume. Finally, stage III is characterized by repetitive quartz and calcite banding with negligible amounts of sulfide minerals. Hydrothermal alteration is developed around the veins and tends to be more intense in the vicinity of the veins. The plot of the Ishikawa alteration index (AI versus chlorite-carbonate-pyrite index (CCPI, known as alteration box plot, displays three main alteration trends. The hydrothermal alteration assemblage of quartz, adularia, chlorite, illite, calcite, and epidote that envelops the Tajroud vein system formed from the upwelling of near-neutral to weakly alkaline hydrothermal solutions. The mineralogic, alteration and geochemical characteristics of the studied area and comparison with epithermal ore deposits indicate that the Tajroud vein system represents an epithermal system of low-sulfidation type.

  13. Varicose vein stripping

    Science.gov (United States)

    ... stripping; Venous reflux - vein stripping; Venous ulcer - veins Patient Instructions Surgical wound care - open Varicose veins - what to ask your doctor Images Circulatory system References American Family Physician. Management of varicose veins. www.aafp.org/afp/2008/ ...

  14. Spoof Detection for Finger-Vein Recognition System Using NIR Camera

    Directory of Open Access Journals (Sweden)

    Dat Tien Nguyen

    2017-10-01

    Full Text Available Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD, is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor based on the observations of the researchers about the difference between real (live and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR camera-based finger-vein recognition system using convolutional neural network (CNN to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA for dimensionality reduction of feature space and support vector machine (SVM for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared

  15. Spoof Detection for Finger-Vein Recognition System Using NIR Camera.

    Science.gov (United States)

    Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung

    2017-10-01

    Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN

  16. Aspects of crack-seal vein system evolution

    OpenAIRE

    Virgo, Simon Matthias

    2015-01-01

    This thesis focuses on the evolution of crack-seal vein systems under changing stress conditions. Thecharacteristics of these highly complex systems are explored in extensive field studies on the Jabal Akhdar(Oman Mountains), an exhumed high-pressure cell with a multiphase deformation history. Theimpact of mechanical heterogeneity on the fracture behavior and structure development in crack-sealvein systems is explored in several numerical studies facilitating the Discrete Element Method (DEM)...

  17. Veins improve fracture toughness of insect wings.

    Directory of Open Access Journals (Sweden)

    Jan-Henning Dirks

    Full Text Available During the lifetime of a flying insect, its wings are subjected to mechanical forces and deformations for millions of cycles. Defects in the micrometre thin membranes or veins may reduce the insect's flight performance. How do insects prevent crack related material failure in their wings and what role does the characteristic vein pattern play? Fracture toughness is a parameter, which characterises a material's resistance to crack propagation. Our results show that, compared to other body parts, the hind wing membrane of the migratory locust S. gregaria itself is not exceptionally tough (1.04±0.25 MPa√m. However, the cross veins increase the wing's toughness by 50% by acting as barriers to crack propagation. Using fracture mechanics, we show that the morphological spacing of most wing veins matches the critical crack length of the material (1132 µm. This finding directly demonstrates how the biomechanical properties and the morphology of locust wings are functionally correlated in locusts, providing a mechanically 'optimal' solution with high toughness and low weight. The vein pattern found in insect wings thus might inspire the design of more durable and lightweight artificial 'venous' wings for micro-air-vehicles. Using the vein spacing as indicator, our approach might also provide a basis to estimate the wing properties of endangered or extinct insect species.

  18. Artificial Neural Network Analysis System

    Science.gov (United States)

    2001-02-27

    Contract No. DASG60-00-M-0201 Purchase request no.: Foot in the Door-01 Title Name: Artificial Neural Network Analysis System Company: Atlantic... Artificial Neural Network Analysis System 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Powell, Bruce C 5d. PROJECT NUMBER 5e. TASK NUMBER...34) 27-02-2001 Report Type N/A Dates Covered (from... to) ("DD MON YYYY") 28-10-2000 27-02-2001 Title and Subtitle Artificial Neural Network Analysis

  19. Artificial intelligence in power system optimization

    CERN Document Server

    Ongsakul, Weerakorn

    2013-01-01

    With the considerable increase of AI applications, AI is being increasingly used to solve optimization problems in engineering. In the past two decades, the applications of artificial intelligence in power systems have attracted much research. This book covers the current level of applications of artificial intelligence to the optimization problems in power systems. This book serves as a textbook for graduate students in electric power system management and is also be useful for those who are interested in using artificial intelligence in power system optimization.

  20. Development of Thrombus in a Systemic Vein after Balloon-Occluded Retrograde Transvenous Obliteration of Gastric Varices

    International Nuclear Information System (INIS)

    Yoshimatsu, Rika; Yamagami, Takuji; Tanaka, Osamu; Miura, Hiroshi; Nishimura, Tsunehiko; Okuda, Kotaro; Hashiba, Mitsuoki

    2012-01-01

    To retrospectively evaluate the frequency and risk factors for developing thrombus in a systemic vein such as the infrarenal inferior vena cava or the iliac vein, in which a balloon-occluded retrograde transvenous obliteration (B-RTO) catheter was indwelled. Forty-nine patients who underwent B-RTO for gastric varices were included in this study. The B-RTO procedure was performed from the right femoral vein, and the B-RTO catheter was retained overnight in all patients. Pre- and post-procedural CT scans were retrospectively compared in order to evaluate the development of thrombus in the systemic vein in which the catheter was indwelled. Additionally, several variables were analyzed to assess risk factors for thrombus in a systemic vein. In all 49 patients (100%), B-RTO was technically successful, and in 46 patients (94%), complete thrombosis of the gastric varices was achieved. In 6 patients (12%), thrombus developed in the infrarenal inferior vena cava or the right common-external iliac vein. All thrombi lay longitudinally on the right side of the inferior vena cava or the right iliac vein. One of the aforementioned 6 patients required anticoagulation therapy. No symptoms suggestive of pulmonary embolism were observed. Prothrombin time-international normalized ratio and the addition of 5% ethanolamine oleate iopamidol, on the second day, were related to the development of thrombus. Development of a thrombus in a systemic vein such as the inferior vena cava or iliac vein, caused by indwelling of the B-RTO catheter, is relatively frequent. Physicians should be aware of the possibility of pulmonary embolism due to iliocaval thrombosis.

  1. Duplex sonography of the near-surface leg veins

    International Nuclear Information System (INIS)

    Mendoza, E.

    2007-01-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins

  2. Towards Robot-Assisted Retinal Vein Cannulation: A Motorized Force-Sensing Microneedle Integrated with a Handheld Micromanipulator †.

    Science.gov (United States)

    Gonenc, Berk; Chae, Jeremy; Gehlbach, Peter; Taylor, Russell H; Iordachita, Iulian

    2017-09-23

    Retinal vein cannulation is a technically demanding surgical procedure where therapeutic agents are injected into the retinal veins to treat occlusions. The clinical feasibility of this approach has been largely limited by the technical challenges associated with performing the procedure. Among the challenges to successful vein cannulation are identifying the moment of venous puncture, achieving cannulation of the micro-vessel, and maintaining cannulation throughout drug delivery. Recent advances in medical robotics and sensing of tool-tissue interaction forces have the potential to address each of these challenges as well as to prevent tissue trauma, minimize complications, diminish surgeon effort, and ultimately promote successful retinal vein cannulation. In this paper, we develop an assistive system combining a handheld micromanipulator, called "Micron", with a force-sensing microneedle. Using this system, we examine two distinct methods of precisely detecting the instant of venous puncture. This is based on measured tool-tissue interaction forces and also the tracked position of the needle tip. In addition to the existing tremor canceling function of Micron, a new control method is implemented to actively compensate unintended movements of the operator, and to keep the cannulation device securely inside the vein following cannulation. To demonstrate the capabilities and performance of our uniquely upgraded system, we present a multi-user artificial phantom study with subjects from three different surgical skill levels. Results show that our puncture detection algorithm, when combined with the active positive holding feature enables sustained cannulation which is most evident in smaller veins. Notable is that the active holding function significantly attenuates tool motion in the vein, thereby reduces the trauma during cannulation.

  3. Towards Robot-Assisted Retinal Vein Cannulation: A Motorized Force-Sensing Microneedle Integrated with a Handheld Micromanipulator †

    Science.gov (United States)

    Gonenc, Berk; Chae, Jeremy; Gehlbach, Peter; Taylor, Russell H.; Iordachita, Iulian

    2017-01-01

    Retinal vein cannulation is a technically demanding surgical procedure where therapeutic agents are injected into the retinal veins to treat occlusions. The clinical feasibility of this approach has been largely limited by the technical challenges associated with performing the procedure. Among the challenges to successful vein cannulation are identifying the moment of venous puncture, achieving cannulation of the micro-vessel, and maintaining cannulation throughout drug delivery. Recent advances in medical robotics and sensing of tool-tissue interaction forces have the potential to address each of these challenges as well as to prevent tissue trauma, minimize complications, diminish surgeon effort, and ultimately promote successful retinal vein cannulation. In this paper, we develop an assistive system combining a handheld micromanipulator, called “Micron”, with a force-sensing microneedle. Using this system, we examine two distinct methods of precisely detecting the instant of venous puncture. This is based on measured tool-tissue interaction forces and also the tracked position of the needle tip. In addition to the existing tremor canceling function of Micron, a new control method is implemented to actively compensate unintended movements of the operator, and to keep the cannulation device securely inside the vein following cannulation. To demonstrate the capabilities and performance of our uniquely upgraded system, we present a multi-user artificial phantom study with subjects from three different surgical skill levels. Results show that our puncture detection algorithm, when combined with the active positive holding feature enables sustained cannulation which is most evident in smaller veins. Notable is that the active holding function significantly attenuates tool motion in the vein, thereby reduces the trauma during cannulation. PMID:28946634

  4. Transport modeling: An artificial immune system approach

    Directory of Open Access Journals (Sweden)

    Teodorović Dušan

    2006-01-01

    Full Text Available This paper describes an artificial immune system approach (AIS to modeling time-dependent (dynamic, real time transportation phenomenon characterized by uncertainty. The basic idea behind this research is to develop the Artificial Immune System, which generates a set of antibodies (decisions, control actions that altogether can successfully cover a wide range of potential situations. The proposed artificial immune system develops antibodies (the best control strategies for different antigens (different traffic "scenarios". This task is performed using some of the optimization or heuristics techniques. Then a set of antibodies is combined to create Artificial Immune System. The developed Artificial Immune transportation systems are able to generalize, adapt, and learn based on new knowledge and new information. Applications of the systems are considered for airline yield management, the stochastic vehicle routing, and real-time traffic control at the isolated intersection. The preliminary research results are very promising.

  5. What Is an Artificial Muscle? A Systemic Approach.

    OpenAIRE

    Bertrand Tondu

    2015-01-01

    Artificial muscles define a large category of actuators we propose to analyze in a systemic framework by considering any artificial muscle as an open-loop stable system for any output which represents an artificial muscle dimension resulting from its “contraction”, understood in a broad meaning. This approach makes it possible to distinguish the artificial muscle from other actuators and to specify an original model for a linear artificial muscle, according to the theory of linear systems. Su...

  6. A dynamical system that describes vein graft adaptation and failure.

    Science.gov (United States)

    Garbey, Marc; Berceli, Scott A

    2013-11-07

    Adaptation of vein bypass grafts to the mechanical stresses imposed by the arterial circulation is thought to be the primary determinant for lesion development, yet an understanding of how the various forces dictate local wall remodeling is lacking. We develop a dynamical system that summarizes the complex interplay between the mechanical environment and cell/matrix kinetics, ultimately dictating changes in the vein graft architecture. Based on a systematic mapping of the parameter space, three general remodeling response patterns are observed: (1) shear stabilized intimal thickening, (2) tension induced wall thinning and lumen expansion, and (3) tension stabilized wall thickening. Notable is our observation that the integration of multiple feedback mechanisms leads to a variety of non-linear responses that would be unanticipated by an analysis of each system component independently. This dynamic analysis supports the clinical observation that the majority of vein grafts proceed along an adaptive trajectory, where grafts dilate and mildly thicken in response to the increased tension and shear, but a small portion of the grafts demonstrate a maladaptive phenotype, where progressive inward remodeling and accentuated wall thickening lead to graft failure. © 2013 The Authors. Published by Elsevier Ltd. All rights reserved.

  7. The umbilical and paraumbilical veins of man.

    Science.gov (United States)

    Martin, B F; Tudor, R G

    1980-03-01

    During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein.

  8. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy - Case report.

    Science.gov (United States)

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B

    2014-12-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.

  9. Sclerotherapy of Varicose Veins and Spider Veins

    Science.gov (United States)

    ... Index A-Z Sclerotherapy of Varicose Veins and Spider Veins Sclerotherapy uses injections from a very fine, ... Sclerotherapy? What is Sclerotherapy of Varicose Veins and Spider Veins? Sclerotherapy is a minimally invasive treatment used ...

  10. Surgery for acquired cardiovascular disease: antiseptic treatment of contaminated vein grafts.

    Science.gov (United States)

    Schmidt, F P; Peivandi, A A; Kohnen, W; Jansen, B

    2014-04-01

    Saphenous vein grafts harvested for use as bypass conduits can be contaminated intraoperatively, e.g. by being inadvertently dropped to the floor of the operating room (OR). This study was performed to investigate microorganisms most likely contaminating vein grafts and to assess the possible efficacy of measures to treat potentially contaminated vein grafts antiseptically for further use. In a first step we determined the microbiological flora of the OR using surface cultures and cultures from intentionally dropped vein grafts. Several antiseptic agents (PVP-iodine 10%, octenidinhydrochloride 0.1%, polyhexanide 1%) were evaluated for their in vitro efficacy to disinfect artificially contaminated vein segments. The most promising antiseptic regimen was tested on veins contaminated in a real OR setting. Finally, we tested for possible alterations in mechanical properties of the veins caused by antiseptic treatment. Coagulase-negative staphylococci where the predominant bacteria recovered from the OR with 59.9%. Antiseptic treatment with a combination of octenidine and PVP-iodine resulted in a higher rate of negative cultures than any single agent. Treatment of 50 saphenous vein grafts contaminated in the OR with the combination regimen resulted in only 3 positive cultural results within 7 days. Mechanical tear-stress testing comparing antiseptically treated vein grafts with controls showed no difference in their resistance to tear stress. Antiseptic treatment of contaminated vein grafts was shown to be effective in a high percentage of cases without altering mechanical properties of grafts and may be an option for the surgeon in case of a contamination.

  11. Vein networks in hydrothermal systems provide constraints for the monitoring of active volcanoes.

    Science.gov (United States)

    Cucci, Luigi; Di Luccio, Francesca; Esposito, Alessandra; Ventura, Guido

    2017-03-10

    Vein networks affect the hydrothermal systems of many volcanoes, and variations in their arrangement may precede hydrothermal and volcanic eruptions. However, the long-term evolution of vein networks is often unknown because data are lacking. We analyze two gypsum-filled vein networks affecting the hydrothermal field of the active Lipari volcanic Island (Italy) to reconstruct the dynamics of the hydrothermal processes. The older network (E1) consists of sub-vertical, N-S striking veins; the younger network (E2) consists of veins without a preferred strike and dip. E2 veins have larger aperture/length, fracture density, dilatancy, and finite extension than E1. The fluid overpressure of E2 is larger than that of E1 veins, whereas the hydraulic conductance is lower. The larger number of fracture intersections in E2 slows down the fluid movement, and favors fluid interference effects and pressurization. Depths of the E1 and E2 hydrothermal sources are 0.8 km and 4.6 km, respectively. The decrease in the fluid flux, depth of the hydrothermal source, and the pressurization increase in E2 are likely associated to a magma reservoir. The decrease of fluid discharge in hydrothermal fields may reflect pressurization at depth potentially preceding hydrothermal explosions. This has significant implications for the long-term monitoring strategy of volcanoes.

  12. Image Quality Enhancement Using the Direction and Thickness of Vein Lines for Finger-Vein Recognition

    Directory of Open Access Journals (Sweden)

    Young Ho Park

    2012-10-01

    Full Text Available On the basis of the increased emphasis placed on the protection of privacy, biometric recognition systems using physical or behavioural characteristics such as fingerprints, facial characteristics, iris and finger-vein patterns or the voice have been introduced in applications including door access control, personal certification, Internet banking and ATM machines. Among these, finger-vein recognition is advantageous in that it involves the use of inexpensive and small devices that are difficult to counterfeit. In general, finger-vein recognition systems capture images by using near infrared (NIR illumination in conjunction with a camera. However, such systems can face operational difficulties, since the scattering of light from the skin can make capturing a clear image difficult. To solve this problem, we proposed new image quality enhancement method that measures the direction and thickness of vein lines. This effort represents novel research in four respects. First, since vein lines are detected in input images based on eight directional profiles of a grey image instead of binarized images, the detection error owing to the non-uniform illumination of the finger area can be reduced. Second, our method adaptively determines a Gabor filter for the optimal direction and width on the basis of the estimated direction and thickness of a detected vein line. Third, by applying this optimized Gabor filter, a clear vein image can be obtained. Finally, the further processing of the morphological operation is applied in the Gabor filtered image and the resulting image is combined with the original one, through which finger-vein image of a higher quality is obtained. Experimental results from application of our proposed image enhancement method show that the equal error rate (EER of finger-vein recognition decreases to approximately 0.4% in the case of a local binary pattern-based recognition and to approximately 0.3% in the case of a wavelet transform

  13. Artificial Intelligence and Spacecraft Power Systems

    Science.gov (United States)

    Dugel-Whitehead, Norma R.

    1997-01-01

    This talk will present the work which has been done at NASA Marshall Space Flight Center involving the use of Artificial Intelligence to control the power system in a spacecraft. The presentation will include a brief history of power system automation, and some basic definitions of the types of artificial intelligence which have been investigated at MSFC for power system automation. A video tape of one of our autonomous power systems using co-operating expert systems, and advanced hardware will be presented.

  14. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy – Case report

    Science.gov (United States)

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B.

    2014-01-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. Conclusion The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival. PMID:25568802

  15. Artificial intelligence techniques in power systems

    Energy Technology Data Exchange (ETDEWEB)

    Laughton, M.A.

    1997-12-31

    Since the early to mid 1980s much of the effort in power systems analysis has turned away from the methodology of formal mathematical modelling which came from the fields of operations research, control theory and numerical analysis to the less rigorous techniques of artificial intelligence (AI). Today the main AI techniques found in power systems applications are those utilising the logic and knowledge representations of expert systems, fuzzy systems, artificial neural networks (ANN) and, more recently, evolutionary computing. These techniques will be outlined in this chapter and the power system applications indicated. (Author)

  16. A DISTRIBUTED SMART HOME ARTIFICIAL INTELLIGENCE SYSTEM

    DEFF Research Database (Denmark)

    Lynggaard, Per

    2013-01-01

    A majority of the research performed today explore artificial intelligence in smart homes by using a centralized approach where a smart home server performs the necessary calculations. This approach has some disadvantages that can be overcome by shifting focus to a distributed approach where...... the artificial intelligence system is implemented as distributed as agents running parts of the artificial intelligence system. This paper presents a distributed smart home architecture that distributes artificial intelligence in smart homes and discusses the pros and cons of such a concept. The presented...... distributed model is a layered model. Each layer offers a different complexity level of the embedded distributed artificial intelligence. At the lowest layer smart objects exists, they are small cheap embedded microcontroller based smart devices that are powered by batteries. The next layer contains a more...

  17. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  18. Pelvic Vein Embolisation in the Management of Varicose Veins

    International Nuclear Information System (INIS)

    Ratnam, Lakshmi A.; Marsh, Petra; Holdstock, Judy M.; Harrison, Charmaine S.; Hussain, Fuad F.; Whiteley, Mark S.; Lopez, Anthony

    2008-01-01

    Pelvic vein incompetence is common in patients with atypical varicose veins, contributing to their recurrence after surgery. Therefore, refluxing pelvic veins should be identified and treated. We present our experience with pelvic vein embolisation in patients presenting with varicose veins. Patients presenting with varicose veins with a duplex-proven contribution from perivulval veins undergo transvaginal duplex sonography (TVUS) to identify refluxing pelvic veins. Those with positive scans undergo embolisation before surgical treatment of their lower limb varicose veins. A total of 218 women (mean age of 46.3 years) were treated. Parity was documented in the first 60 patients, of whom 47 (78.3%) were multiparous, 11 (18.3%) had had one previous pregnancy, and 2 (3.3%) were nulliparous. The left ovarian vein was embolised in 78%, the right internal iliac in 64.7%, the left internal iliac in 56.4%, and the right ovarian vein in 42.2% of patients. At follow-up TVUS, mild reflux only was seen in 16, marked persistent reflux in 6, and new reflux in 3 patients. These 9 women underwent successful repeat embolisation. Two patients experienced pulmonary embolisation of the coils, of whom 1 was asymptomatic and 1 was successfully retrieved; 1 patient had a misplaced coil protruding into the common femoral vein; and 1 patient had perineal thrombophlebitis. The results of our study showed that pelvic venous embolisation by way of a transjugular approach is a safe and effective technique in the treatment of pelvic vein reflux.

  19. In-vivo imaging of the sentinel vein using the near-infrared vascular imaging system in hallux valgus patients.

    Science.gov (United States)

    Nakasa, Tomoyuki; Ishikawa, Masakazu; Ikuta, Yasunari; Yoshikawa, Masahiro; Sawa, Mikiya; Tsuyuguchi, Yusuke; Adachi, Nobuo

    2017-11-01

    A high incidence of dorsomedial cutaneous nerve (DMCN) damage in hallux valgus surgery has been reported. Identification of the vein around 1st metatarsal head is reported to be helpful to reduce the DMCN damage during surgery. The near-infrared (NIR) vascular imaging system, the VeinViewer ® Flex, projects the vein onto the skin. The purpose of this study was to investigate the difference of the vein course between normal and hallux valgus foot using the VeinViewer ® Flex, and to validate that the DMCN was accompanied with its vein. Twenty-seven feet with the hallux valgus and 27 feet in healthy subjects were included. The vein was projected onto the skin at the metatarsal head by the VeinViewer ® Flex. The distance between the vein and the mid-line of the metatarsal head was measured. The correlation of the distance and hallux valgus angle or 1-2 intermetatarsal angle (IMA) was analyzed. The vein depicted by the VeinViewer ® Flex and operative findings was compared in 4 patients during surgery. The vein in the hallux valgus patients shifted toward the dorsolateral side on the metatarsal bone head compared to that in healthy subjects. The distance from the midline of the 1st metatarsal bone to the vein in the hallux valgus (12.1 mm) was significantly higher than that in healthy subjects (2.7 mm) (p hallux valgus patients shifted toward the dorsolateral on the metatarsal bone and it could be a landmark to identify DMCN. The NIR vascular imaging system would be useful to reduce the risk of nerve damage in great toe surgery. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  20. Systemic thrombolysis of portal vein thrombosis in cirrhotic patients: a pilot study.

    Science.gov (United States)

    De Santis, Adriano; Moscatelli, Rosanna; Catalano, Carlo; Iannetti, Antonio; Gigliotti, Francesca; Cristofari, Francesca; Trapani, Silvia; Attili, Adolfo F

    2010-06-01

    Portal vein thrombosis is a frequent complication in liver cirrhosis. Encouraging reports of systemic thrombolysis in non-cirrhotic patients suffering from acute portal vein thrombosis led us to start a pilot study on the efficacy and safety of systemic low dose recombinant tissue plasminogen activator (Actilyse, Boheringer Ingelheim, Florence, Italy). Nine cirrhotic patients (6 males and 3 females) with recent portal vein thrombosis were enrolled. Exclusion criteria were portal cavernomatosis, recent (30 days) surgery, active bleeding, hepatocellular carcinoma and cancer in other sites. All cases were treated for a maximum of 7 days by continuous i.v. infusion of 0.25mg/kg/die of r-tPA plus subcutaneous low molecular weight heparin. Efficacy was evaluated by colour doppler sonography monitoring and confirmed by contrast enhanced computerized tomography. The combined r-tPA/LMWH treatment was well tolerated without clinically significant side effects. Complete resolution of thrombosis occurred in 4 cases, partial regression in 4 and none in 1. Retreatment of a complete recurrence in 1 patient was successful. Variceal pressure dropped from 30.7+/-4.5 mmHg to 21.2+/-6.6 mmHg (p=0.012). Our preliminary data demonstrate that thrombolytic treatment of recent portal vein thrombosis with i.v. r-tPA and LMWH in patients with cirrhosis appears to be safe and effective and can significantly reduce pressure in oesophageal varices. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  1. Artificial intelligence and information-control systems of robots - 87

    International Nuclear Information System (INIS)

    Plander, I.

    1987-01-01

    Independent research areas of artificial intelligence represent the following problems: automatic problem solving and new knowledge discovering, automatic program synthesis, natural language, picture and scene recognition and understanding, intelligent control systems of robots equipped with sensoric subsystems, dialogue of two knowledge systems, as well as studying and modelling higher artificial intelligence attributes, such as emotionality and personality. The 4th Conference draws on the problems treated at the preceding Conferences, and presents the most recent knowledge on the following topics: theoretical problems of artificial intelligence, knowledge-based systems, expert systems, perception and pattern recognition, robotics, intelligent computer-aided design, special-purpose computer systems for artificial intelligence and robotics

  2. Regional differences in endothelial cell cytoskeleton, junctional proteins and phosphorylated tyrosine labeling in the porcine vortex vein system.

    Science.gov (United States)

    Tan, Priscilla Ern Zhi; Yu, Paula K; Yang, Hongfang; Cringle, Stephen J; Yu, Dao-Yi

    2018-07-01

    We previously demonstrated endothelial phenotype heterogeneity in the vortex vein system. This study is to further determine whether regional differences are present in the cytoskeleton, junctional proteins and phosphorylated tyrosine labeling within the system. The vortex vein system of twenty porcine eyes was perfused with labels for f-actin, claudin-5, VE-Cadherin, phosphorylated tyrosine and nucleic acid. The endothelial cells of eight different regions (choroidal veins, pre-ampulla, anterior ampulla, mid-ampulla, posterior ampulla, post-ampulla, intra-scleral canal and the extra-ocular vortex vein) were studied using confocal microscopy. There were regional differences in the endothelial cell structures. Cytoskeleton labeling was relatively even in intensity throughout Regions 1 to 6. Overall VE-Cadherin had a non-uniform distribution and thicker width endothelial cell border staining than claudin-5. Progressing downstream there was an increased variation in thickness of VE-cadherin labeling. There was an overlap in phosphorylated tyrosine and VE-Cadherin labeling in the post-ampulla, intra-scleral canal and extra-ocular vortex vein. Intramural cells were observed that were immune-positive for VE-Cadherin and phosphorylated tyrosine. There were significant differences in the number of intramural cells in different regions. Significant regional differences with endothelial cell labeling of cytoskeleton, junction proteins, and phosphorylated tyrosine were found within the vortex vein system. These findings support existing data on endothelial cell phenotype heterogeneity, and may aid in the knowledge of venous pathologies by understanding regions of vulnerability to endothelial damage within the vortex vein system. It could be valuable to further investigate and characterize the VE-cadherin and phosphotyrosine immune-positive intramural cells. Copyright © 2018. Published by Elsevier Ltd.

  3. Assessment and management of patients with varicose veins.

    Science.gov (United States)

    Allen, Louise

    Varicose veins are enlarged superficial veins found in the legs. This article explores the anatomy and physiology of the venous system to assist nurses to assess, manage and treat patients with varicose veins.

  4. Fluid transfer and vein thickness distribution in high and low temperature hydrothermal systems at shallow crustal level in southern Tuscany (Italy

    Directory of Open Access Journals (Sweden)

    Francesco Mazzarini

    2014-06-01

    Full Text Available Geometric analysis of vein systems hosted in upper crustal rocks and developed in high and low temperature hydrothermal systems is presented. The high temperature hydrothermal system consists of tourmaline-rich veins hosted within the contact aureole of the upper Miocene Porto Azzurro pluton in the eastern Elba Island. The low temperature hydrothermal system consists of calcite-rich veins hosted within the Oligocene sandstones of the Tuscan Nappe, exposed along the coast in southern Tuscany. Vein thickness distribution is here used as proxy for inferring some hydraulic properties (transmissivity of the fluid circulation at the time of veins’ formation. We derive estimations of average thickness of veins by using the observed distributions. In the case of power law thickness distributions, the lower the scaling exponent of the distribution the higher the overall transmissivity. Indeed, power law distributions characterised by high scaling exponents have transmissivity three order of magnitude lower than negative exponential thickness distribution. Simple observations of vein thickness may thus provides some clues on the transmissivity in hydrothermal systems.

  5. Veias do sistema porta-hepático em gansos domésticos Veins from hepatic portal vein system in domestic geese

    Directory of Open Access Journals (Sweden)

    Tatiana C. Santos

    2009-04-01

    hepatic lobe, connected by a parenchyma bridge. The right hepatic lobe had vessels exclusively from the hepatic portal system composed by intraparenchymal distribution of the right hepatic portal vein, while the vessels of the left hepatic lobe came from the right hepatic portal vein and from small left hepatic portal veins. The right hepatic portal vein emitted the right caudal branch, which emitted a small right caudolateral branch and a large right caudomedial branch. Cranially this vein emitted right cranial and right lateral branches. The tranverse portion of the right hepatic portal vein crossed to the left hepatic lobe, emitting 1 to 6 small cranial and caudal branches to the medial area of the liver. In the left hepatic lobe, the left branch from the right hepatic vein emitted the left cranial, left lateral and left median branches. One to six left hepatic portal veins were identified arising from the left branch or from the transverse portion of the right hepatic portal vein. These vessels arose from the gizzard and pro-ventricle. In 40% of geese one proper hepatic portal vein originated from venous vessels of the gizzard and was distributed into the caudal extremity of the left hepatic isolated lobe.

  6. Duplex sonography of the near-surface leg veins; Duplexsonographie der oberflaechlichen Beinvenen

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, E.

    2007-07-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins.

  7. Artificial and bioartificial support systems for liver failure

    DEFF Research Database (Denmark)

    Liu, J P; Gluud, L L; Als-Nielsen, B

    2004-01-01

    Artificial and bioartificial liver support systems may 'bridge' patients with acute or acute-on-chronic liver failure to liver transplantation or recovery.......Artificial and bioartificial liver support systems may 'bridge' patients with acute or acute-on-chronic liver failure to liver transplantation or recovery....

  8. Artificial immune system algorithm in VLSI circuit configuration

    Science.gov (United States)

    Mansor, Mohd. Asyraf; Sathasivam, Saratha; Kasihmuddin, Mohd Shareduwan Mohd

    2017-08-01

    In artificial intelligence, the artificial immune system is a robust bio-inspired heuristic method, extensively used in solving many constraint optimization problems, anomaly detection, and pattern recognition. This paper discusses the implementation and performance of artificial immune system (AIS) algorithm integrated with Hopfield neural networks for VLSI circuit configuration based on 3-Satisfiability problems. Specifically, we emphasized on the clonal selection technique in our binary artificial immune system algorithm. We restrict our logic construction to 3-Satisfiability (3-SAT) clauses in order to outfit with the transistor configuration in VLSI circuit. The core impetus of this research is to find an ideal hybrid model to assist in the VLSI circuit configuration. In this paper, we compared the artificial immune system (AIS) algorithm (HNN-3SATAIS) with the brute force algorithm incorporated with Hopfield neural network (HNN-3SATBF). Microsoft Visual C++ 2013 was used as a platform for training, simulating and validating the performances of the proposed network. The results depict that the HNN-3SATAIS outperformed HNN-3SATBF in terms of circuit accuracy and CPU time. Thus, HNN-3SATAIS can be used to detect an early error in the VLSI circuit design.

  9. Building Explainable Artificial Intelligence Systems

    National Research Council Canada - National Science Library

    Core, Mark G; Lane, H. Chad; van Lent, Michael; Gomboc, Dave; Solomon, Steve; Rosenberg, Milton

    2006-01-01

    As artificial intelligence (AI) systems and behavior models in military simulations become increasingly complex, it has been difficult for users to understand the activities of computer-controlled entities...

  10. An unusual case: right proximal ureteral compression by the ovarian vein and distal ureteral compression by the external iliac vein

    Directory of Open Access Journals (Sweden)

    Halil Ibrahim Serin

    2015-12-01

    Full Text Available A 32-years old woman presented to the emergency room of Bozok University Research Hospital with right renal colic. Multidetector computed tomography (MDCT showed compression of the proximal ureter by the right ovarian vein and compression of the right distal ureter by the right external iliac vein. To the best of our knowledge, right proximal ureteral compression by the ovarian vein together with distal ureteral compression by the external iliac vein have not been reported in the literature. Ovarian vein and external iliac vein compression should be considered in patients presenting to the emergency room with renal colic or low back pain and a dilated collecting system.

  11. FPGA controlled artificial vascular system

    Directory of Open Access Journals (Sweden)

    Laqua D.

    2015-09-01

    Full Text Available Monitoring the oxygen saturation of an unborn child is an invasive procedure, so far. Transabdominal fetal pulse oximetry is a promising method under research, used to estimate the oxygen saturation of a fetus noninvasively. Due to the nature of the method, the fetal information needs to be extracted from a mixed signal. To properly evaluate signal processing algorithms, a phantom modeling fetal and maternal blood circuits and tissue layers is necessary. This paper presents an improved hardware concept for an artificial vascular system, utilizing an FPGA based CompactRIO System from National Instruments. The experimental model to simulate the maternal and fetal blood pressure curve consists of two identical hydraulic circuits. Each of these circuits consists of a pre-pressure system and an artificial vascular system. Pulse curves are generated by proportional valves, separating these two systems. The dilation of the fetal and maternal artificial vessels in tissue substitutes is measured by transmissive and reflective photoplethysmography. The measurement results from the pressure sensors and the transmissive optical sensors are visualized to show the functionality of the pulse generating systems. The trigger frequency for the maternal valve was set to 1 per second, the fetal valve was actuated at 0.7 per second for validation. The reflective curve, capturing pulsations of the fetal and maternal circuit, was obtained with a high power LED (905 nm as light source. The results show that the system generates pulse curves, similar to its physiological equivalent. Further, the acquired reflective optical signal is modulated by the alternating diameter of the tubes of both circuits, allowing for tests of signal processing algorithms.

  12. An Artificial Intelligence-Based Environment Quality Analysis System

    OpenAIRE

    Oprea , Mihaela; Iliadis , Lazaros

    2011-01-01

    Part 20: Informatics and Intelligent Systems Applications for Quality of Life information Services (ISQLIS) Workshop; International audience; The paper describes an environment quality analysis system based on a combination of some artificial intelligence techniques, artificial neural networks and rule-based expert systems. Two case studies of the system use are discussed: air pollution analysis and flood forecasting with their impact on the environment and on the population health. The syste...

  13. Nuclear-powered artificial heart system

    International Nuclear Information System (INIS)

    Pouchot, W.D.; Lehrfeld, D.

    1976-01-01

    As reported to the 9th IECEC, a bench model version of a nuclear-powered artificial heart system to be used as a replacement for the natural heart was constructed and tested as part of a broader U.S. ERDA program. A report is given of the system design and integration, bench testing, and field support equipment of an implantable and advanced version of the bench model incorporating some of the component developments reported to the 10th IECEC. The basic elements of the system are a 32-watt Pu-238 heat source, a Stirling engine thermal converter, a coupling mechanism, and a mechanical blood pump drive actuating, alternatively, two artificial ventricles of polymeric material. As tested on the bench using a mock circulation, the system provides approximately 9 liters/minute at 120/80 mm Hg aortic pressure. At 190/145 mm Hg aortic pressure, the maximum flow decreases to about 7 liters/minute

  14. Artificial intelligence in robot control systems

    Science.gov (United States)

    Korikov, A.

    2018-05-01

    This paper analyzes modern concepts of artificial intelligence and known definitions of the term "level of intelligence". In robotics artificial intelligence system is defined as a system that works intelligently and optimally. The author proposes to use optimization methods for the design of intelligent robot control systems. The article provides the formalization of problems of robotic control system design, as a class of extremum problems with constraints. Solving these problems is rather complicated due to the high dimensionality, polymodality and a priori uncertainty. Decomposition of the extremum problems according to the method, suggested by the author, allows reducing them into a sequence of simpler problems, that can be successfully solved by modern computing technology. Several possible approaches to solving such problems are considered in the article.

  15. First North American 50 cc Total Artificial Heart Experience: Conversion from a 70 cc Total Artificial Heart.

    Science.gov (United States)

    Khalpey, Zain; Kazui, Toshinobu; Ferng, Alice S; Connell, Alana; Tran, Phat L; Meyer, Mark; Rawashdeh, Badi; Smith, Richard G; Sweitzer, Nancy K; Friedman, Mark; Lick, Scott; Slepian, Marvin J; Copeland, Jack G

    2016-01-01

    The 70 cc total artificial heart (TAH) has been utilized as bridge to transplant (BTT) for biventricular failure. However, the utilization of 70 cc TAH has been limited to large patients for the low output from the pulmonary as well as systemic vein compression after chest closure. Therefore, the 50 cc TAH was developed by SynCardia (Tucson, AZ) to accommodate smaller chest cavity. We report the first TAH exchange from a 70 to 50 cc due to a fit difficulty. The patient failed to be closed with a 70 cc TAH, although the patient met the conventional 70 cc TAH fit criteria. We successfully closed the chest with a 50 cc TAH.

  16. Arabidopsis thaliana Ei-5: Minor Vein Architecture Adjustment Compensates for Low Vein Density in Support of Photosynthesis.

    Science.gov (United States)

    Stewart, Jared J; Polutchko, Stephanie K; Demmig-Adams, Barbara; Adams, William W

    2018-01-01

    An Arabidopsis thaliana accession with naturally low vein density, Eifel-5 (Ei-5), was compared to Columbia-0 (Col-0) with respect to rosette growth, foliar vein architecture, photosynthesis, and transpiration. In addition to having to a lower vein density, Ei-5 grew more slowly, with significantly lower rates of rosette expansion, but had similar capacities for photosynthetic oxygen evolution on a leaf area basis compared to Col-0. The individual foliar minor veins were larger in Ei-5, with a greater number of vascular cells per vein, compared to Col-0. This compensation for low vein density resulted in similar values for the product of vein density × phloem cell number per minor vein in Ei-5 and Col-0, which suggests a similar capacity for foliar sugar export to support similar photosynthetic capacities per unit leaf area. In contrast, the product of vein density × xylem cell number per minor vein was significantly greater in Ei-5 compared to Col-0, and was associated not only with a higher ratio of water-transporting tracheary elements versus sugar-transporting sieve elements but also significantly higher foliar transpiration rates per leaf area in Ei-5. In contrast, previous studies in other systems had reported higher ratios of tracheary to sieve elements and higher transpiration rate to be associated with higher - rather than lower - vein densities. The Ei-5 accession thus further underscores the plasticity of the foliar vasculature by illustrating an example where a higher ratio of tracheary to sieve elements is associated with a lower vein density. Establishment of the Ei-5 accession, with a low vein density but an apparent overcapacity for water flux through the foliar xylem network, may have been facilitated by a higher level of precipitation in its habitat of origin compared to that of the Col-0 accession.

  17. Abstraction in artificial intelligence and complex systems

    CERN Document Server

    Saitta, Lorenza

    2013-01-01

    Abstraction is a fundamental mechanism underlying both human and artificial perception, representation of knowledge, reasoning and learning. This mechanism plays a crucial role in many disciplines, notably Computer Programming, Natural and Artificial Vision, Complex Systems, Artificial Intelligence and Machine Learning, Art, and Cognitive Sciences. This book first provides the reader with an overview of the notions of abstraction proposed in various disciplines by comparing both commonalities and differences.  After discussing the characterizing properties of abstraction, a formal model, the K

  18. Artificial Intelligence and Expert Systems.

    Science.gov (United States)

    Wilson, Harold O.; Burford, Anna Marie

    1990-01-01

    Delineates artificial intelligence/expert systems (AI/ES) concepts; provides an exposition of some business application areas; relates progress; and creates an awareness of the benefits, limitations, and reservations of AI/ES. (Author)

  19. Anomalous adrenal vein anatomy complicating the evaluation of primary hyperaldosteronism

    Directory of Open Access Journals (Sweden)

    Kaitlin M. Ford, BS

    2018-02-01

    Full Text Available Adrenal vein development in utero occurs concurrently with the development of the inferior vena cava, the renal veins, and the gonadal veins. The embryologic formation of these veins involves communication of various venous systems. Although the left adrenal-renal vein complex is most commonly described as a shared emptying of the left adrenal vein and the left inferior phrenic vein into the left renal vein, there have been reports of numerous anatomic variations of this complex. In this report, we present a case of a rare variant of the left adrenal vein, in which the left adrenal vein empties into the left gonadal vein, which takes an atypical course superolateral to the left kidney.

  20. Abnormal systemic venous connection possibly associated with a persistent right umbilical vein; a case report

    Directory of Open Access Journals (Sweden)

    Smevik Bjarne

    2004-04-01

    Full Text Available Abstract Background Abnormal venous connections involving a persistent right umbilical vein are rare. In a minority of cases the liver is entirely bypassed and the condition is associated with multiple congenital malformations. Case presentation The described case illustrates a systemic venous drainage that was severely abnormal in a newborn girl with a truncus arteriosus type II congenital heart defect. Injection of contrast medium through the umbilical vein catheter revealed a very peculiar venous connection that passed anterio-laterally through the right hemithorax before crossing in an oblique fashion towards the superior vena cava. Conclusions This venous drainage may be the result of a persistent right umbilical vein connecting with the superior vena cava.

  1. Predicting risk for portal vein thrombosis in acute pancreatitis patients: A comparison of radical basis function artificial neural network and logistic regression models.

    Science.gov (United States)

    Fei, Yang; Hu, Jian; Gao, Kun; Tu, Jianfeng; Li, Wei-Qin; Wang, Wei

    2017-06-01

    To construct a radical basis function (RBF) artificial neural networks (ANNs) model to predict the incidence of acute pancreatitis (AP)-induced portal vein thrombosis. The analysis included 353 patients with AP who had admitted between January 2011 and December 2015. RBF ANNs model and logistic regression model were constructed based on eleven factors relevant to AP respectively. Statistical indexes were used to evaluate the value of the prediction in two models. The predict sensitivity, specificity, positive predictive value, negative predictive value and accuracy by RBF ANNs model for PVT were 73.3%, 91.4%, 68.8%, 93.0% and 87.7%, respectively. There were significant differences between the RBF ANNs and logistic regression models in these parameters (Plogistic regression model. D-dimer, AMY, Hct and PT were important prediction factors of approval for AP-induced PVT. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. A Characterization of the Utility of Using Artificial Intelligence to Test Two Artificial Intelligence Systems

    Directory of Open Access Journals (Sweden)

    Jeremy Straub

    2013-05-01

    Full Text Available An artificial intelligence system, designed for operations in a real-world environment faces a nearly infinite set of possible performance scenarios. Designers and developers, thus, face the challenge of validating proper performance across both foreseen and unforeseen conditions, particularly when the artificial intelligence is controlling a robot that will be operating in close proximity, or may represent a danger, to humans. While the manual creation of test cases allows limited testing (perhaps ensuring that a set of foreseeable conditions trigger an appropriate response, this may be insufficient to fully characterize and validate safe system performance. An approach to validating the performance of an artificial intelligence system using a simple artificial intelligence test case producer (AITCP is presented. The AITCP allows the creation and simulation of prospective operating scenarios at a rate far exceeding that possible by human testers. Four scenarios for testing an autonomous navigation control system are presented: single actor in two-dimensional space, multiple actors in two-dimensional space, single actor in three-dimensional space, and multiple actors in three-dimensional space. The utility of using the AITCP is compared to that of human testers in each of these scenarios.

  3. Portal Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Hakan Demirci

    2016-01-01

    Full Text Available Portal vein thrombosis is an important cause of presinusoidal portal hypertension. Portal vein thrombosis commonly occurs in patient with cirrhosis, malignancy and prothrombotic states. Patients with acute portal vein thrombosis have immediate onset. Patients with chronic portal vein thrombosis have developed portal hypertension and cavernous portal transformation. Portal vein thrombosis is diagnosed with doppler ultrasound, computed tomography and magnetic resonance imaging. Therapy with low molecular weight heparin achieves recanalization in more than half of acute cases.

  4. Collateral veins in left renal vein stenosis demonstrated via CT

    Energy Technology Data Exchange (ETDEWEB)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-02-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development.

  5. Collateral veins in left renal vein stenosis demonstrated via CT

    International Nuclear Information System (INIS)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-01-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development. (orig.)

  6. Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

    Science.gov (United States)

    Hanazaki, Kazuhiro; Munekage, Masaya; Kitagawa, Hiroyuki; Yatabe, Tomoaki; Munekage, Eri; Shiga, Mai; Maeda, Hiromichi; Namikawa, Tsutomu

    2016-09-01

    The incidence of diabetes is increasing at an unprecedented pace and has become a serious health concern worldwide during the last two decades. Despite this, adequate glycemic control using an artificial pancreas has not been established, although the 21st century has seen rapid developments in this area. Herein, we review current topics in glycemic control for both the wearable artificial pancreas for type 1 and type 2 diabetic patients and the bedside artificial pancreas for surgical diabetic patients. In type 1 diabetic patients, nocturnal hypoglycemia associated with insulin therapy remains a serious problem that could be addressed by the recent development of a wearable artificial pancreas. This smart phone-like device, comprising a real-time, continuous glucose monitoring system and insulin pump system, could potentially significantly reduce nocturnal hypoglycemia compared with conventional glycemic control. Of particular interest in this space are the recent inventions of a low-glucose suspend feature in the portable systems that automatically stops insulin delivery 2 h following a glucose sensor value <70 mg/dL and a bio-hormonal pump system consisting of insulin and glucagon pumps. Perioperative tight glycemic control using a bedside artificial pancreas with the closed-loop system has also proved safe and effective for not only avoiding hypoglycemia, but also for reducing blood glucose level variability resulting in good surgical outcomes. We hope that a more sophisticated artificial pancreas with closed-loop system will now be taken up for routine use worldwide, providing enormous relief for patients suffering from uncontrolled hyperglycemia, hypoglycemia, and/or variability in blood glucose concentrations.

  7. Focus on Varicose Veins

    Science.gov (United States)

    ... because the valves of the veins no longer work. Under the pressure of gravity these veins can continue to expand and, in ... and to determine whether the vein valves are work- ing properly or have ... painless. How are varicose veins treated? Varicose veins are always ...

  8. The deconvolution of complex spectra by artificial immune system

    Science.gov (United States)

    Galiakhmetova, D. I.; Sibgatullin, M. E.; Galimullin, D. Z.; Kamalova, D. I.

    2017-11-01

    An application of the artificial immune system method for decomposition of complex spectra is presented. The results of decomposition of the model contour consisting of three components, Gaussian contours, are demonstrated. The method of artificial immune system is an optimization method, which is based on the behaviour of the immune system and refers to modern methods of search for the engine optimization.

  9. Image Quality Enhancement Using the Direction and Thickness of Vein Lines for Finger-Vein Recognition

    OpenAIRE

    Park, Young Ho; Park, Kang Ryoung

    2012-01-01

    On the basis of the increased emphasis placed on the protection of privacy, biometric recognition systems using physical or behavioural characteristics such as fingerprints, facial characteristics, iris and finger‐vein patterns or the voice have been introduced in applications including door access control, personal certification, Internet banking and ATM machines. Among these, finger‐vein recognition is advantageous in that it involves the use of inexpensive and small devices that are diffic...

  10. Counseling, Artificial Intelligence, and Expert Systems.

    Science.gov (United States)

    Illovsky, Michael E.

    1994-01-01

    Considers the use of artificial intelligence and expert systems in counseling. Limitations are explored; candidates for counseling versus those for expert systems are discussed; programming considerations are reviewed; and techniques for dealing with rational, nonrational, and irrational thoughts and feelings are described. (Contains 46…

  11. Spider Vein Removal

    Science.gov (United States)

    Spider veins: How are they removed? I have spider veins on my legs. What options are available ... M.D. Several options are available to remove spider veins — thin red lines or weblike networks of ...

  12. [Review of wireless energy transmission system for total artificial heart].

    Science.gov (United States)

    Zhang, Chi; Yang, Ming

    2009-11-01

    This paper sums up the fundamental structure of wireless energy transmission system for total artificial heart, and compares the key parameters and performance of some representative systems. After that, it is discussed that the future development trend of wireless energy transmission system for total artificial heart.

  13. What Are Varicose Veins?

    Science.gov (United States)

    ... Leer en español What Is Varicose (VAR-i-kos) veins are swollen, twisted veins that you can ... TA-ze-uhs), spider veins, varicoceles (VAR-i-ko-seals), and other vein problems. Telangiectasias Telangiectasias are ...

  14. Treatment of hepatic encephalopathy by retrograde transcaval coil embolization of an ileal vein-to-right gonadal vein portosystemic shunt

    International Nuclear Information System (INIS)

    Nishie, Akihiro; Yoshimitsu, Kengo; Honda, Hiroshi; Kaneko, Kuniyuki; Kuroiwa, Toshiro; Fukuya, Tatsuro; Irie, Hiroyuki; Ninomiya, Toshiharu; Yoshimitsu, Takahiro; Hirakata, Hideki; Okuda, Seiya; Masuda, Kouji

    1997-01-01

    A 43-year-old non-cirrhotic woman suffered from encephalopathy caused by an extrahepatic portosystemic shunt between the ileal vein and inferior vena cava via the right gonadal vein. Percutaneous transcatheter embolization with stainless steel coils was performed by the retrograde systemic venous approach. Encephalopathy improved dramatically

  15. Stability of Bifurcating Stationary Solutions of the Artificial Compressible System

    Science.gov (United States)

    Teramoto, Yuka

    2018-02-01

    The artificial compressible system gives a compressible approximation of the incompressible Navier-Stokes system. The latter system is obtained from the former one in the zero limit of the artificial Mach number ɛ which is a singular limit. The sets of stationary solutions of both systems coincide with each other. It is known that if a stationary solution of the incompressible system is asymptotically stable and the velocity field of the stationary solution satisfies an energy-type stability criterion, then it is also stable as a solution of the artificial compressible one for sufficiently small ɛ . In general, the range of ɛ shrinks when the spectrum of the linearized operator for the incompressible system approaches to the imaginary axis. This can happen when a stationary bifurcation occurs. It is proved that when a stationary bifurcation from a simple eigenvalue occurs, the range of ɛ can be taken uniformly near the bifurcation point to conclude the stability of the bifurcating solution as a solution of the artificial compressible system.

  16. Varicose vein - noninvasive treatment

    Science.gov (United States)

    ... spider veins. These are small varicose veins. Salt water (saline) or a chemical solution is injected into the varicose vein. The vein will harden and then disappear. Laser treatment can be used on the surface of the skin. Small bursts ...

  17. Systems with artificial intelligence in nuclear power plant operation

    International Nuclear Information System (INIS)

    Bastl, W.; Felkel, L.

    1989-01-01

    The authors first summarize some developments made by GRS teams which can be regarded as the precursors of systems with artificial intelligence, and explain the basic characteristics of artificial intelligence, referring in particular to possible applications in nuclear engineering. The systems described are arranged in four groups according to applicability as follows: plant diagnosis and failure analysis, information systems and operating systems, control systems, assessment and decision aids. The working principle of the systems is explained by some examples giving details of the database and the interference processes. (orig./DG) [de

  18. Geometric Analysis of Vein Fracture Networks From the Awibengkok Core, Indonesia

    Science.gov (United States)

    Khatwa, A.; Bruhn, R. L.; Brown, S. R.

    2003-12-01

    Fracture network systems within rocks are important features for the transportation and remediation of hazardous waste, oil and gas production, geothermal energy extraction and the formation of vein fillings and ore deposits. A variety of methods, including computational and laboratory modeling have been employed to further understand the dynamic nature of fractures and fracture systems (e.g. Ebel and Brown, this session). To substantiate these studies, it is also necessary to analyze the characteristics and morphology of naturally occurring vein systems. The Awibengkok core from a geothermal system in West Java, Indonesia provided an excellent opportunity to study geometric and petrologic characteristics of vein systems in volcanic rock. Vein minerals included chlorite, calcite, quartz, zeolites and sulphides. To obtain geometric data on the veins, we employed a neural net image processing technique to analyze high-resolution digital photography of the veins. We trained a neural net processor to map the extent of the vein using RGB pixel training classes. The resulting classification image was then converted to a binary image file and processed through a MatLab program that we designed to calculate vein geometric statistics, including aperture and roughness. We also performed detailed petrographic and microscopic geometric analysis on the veins to determine the history of mineralization and fracturing. We found that multi-phase mineralization due to chemical dissolution and re-precipitation as well as mechanical fracturing was a common feature in many of the veins and that it had a significant role for interpreting vein tortuosity and history of permeability. We used our micro- and macro-scale observations to construct four hypothetical permeability models that compliment the numerical and laboratory modeled data reported by Ebel and Brown. In each model, permeability changes, and in most cases fluctuates, differently over time as the tortuosity and aperture of

  19. MULTIPLE VARIATIONS OF THE SUPERFICIAL JUGULAR VEINS: CASE REPORT AND CLINICAL RELEVANCE

    Directory of Open Access Journals (Sweden)

    George Paraskevas

    2014-01-01

    Full Text Available The jugular venous system constitutes the primary venous drainage of the head and neck. It includes a profundus or subfascial venous system, formed by the two internal jugular veins, and a superficial or subcutaneous one, formed by the two anterior and two external jugular veins. We report one case of unilateral anatomical variations of the external and anterior jugular veins. Particularly, on the right side, three external jugular veins co-existed with two anterior jugular veins. Such a combination of venous anomalies is extremely rare. The awareness of the variability of these veins is essential to anesthesiologists and radiologists, since the external jugular vein constitutes a common route for catheterization. Their knowledge is also important to surgeons performing head and neck surgery.

  20. Geology and geochemistry of epithermal precious metal vein systems in the intra-oceanic arcs of Palau and Yap, western Pacific

    Science.gov (United States)

    Rytuba, J.J.; Miller, W.R.

    1990-01-01

    The Palau and Yap arcs are part of an intra-oceanic island-arc-trench system which separates the Pacific and Philippine plates in the western Pacific Ocean. The 350-km-long Palau arc consists of over 200 islands while the 400-km-long Yap arc located to the north has only four major islands exposed. Four of the largest islands in Palau are composed primarily of early Eocene to mid-Miocene volcanic rocks and the four islands comprising Yap contain only Miocene volcanic rocks. Basalt and basaltic andesites of the Babelthuap Formation are the oldest volcanic rocks in Palau and are characterized by high MgO, Ni and Cr and low TiO2 and have a boninitic affinity. They form the central and southeastern parts of Babelthuap Island. Oligocene arc tholeiite flows having an age of 34-35.5 Ma comprise most of the three smaller volcanic islands in Palau and the western part of Babelthuap. The youngest volcanic rocks are dacitic intrusions having an age of 22.7-23.2 Ma. The Yap arc is unusual in that metamorphic rocks up to amphibolite grade form most of the islands. These are underlain by a melange composed of igneous and volcanic clasts as well as clasts from a dismembered copper-gold skarn deposit. Miocene volcanic rocks consisting of flows and volcaniclastic deposits overlie the melange and metamorphic complex. An epithermal precious-metal vein system hosted by flows and flow breccias of the Babelthuap Formation occurs in an area 1.5 km by 1 km on the southeast side of Babelthuap Island. Over 50 veins and mineralized breccias ranging up to 2 m in width and having a strike length up to 500 m contain from trace to 13.0 ppm gold. The veins consist of quartz with varying amounts of sulfides and iron oxides after sulfides and the mineralized breccias consist of brecciated country rock cemented by quartz and iron oxides after sulfides. The veins and mineralized breccias generally dip within 15?? of vertical and have two preferred orientations, north-northwest and north

  1. VAR control in distribution systems by using artificial intelligence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Golkar, M.A. [Curtin Univ. of Technology, Sarawak (Malaysia). School of Engineering and Science

    2005-07-01

    This paper reviewed artificial intelligence techniques used in VAR control systems. Reactive power controls in distribution systems were also reviewed. While artificial intelligence methods are widely used in power control systems, the techniques require extensive human knowledge bases and experiences in order to operate correctly. Expert systems use knowledge and interface procedures to solve problems that often require human expertise. Expert systems often cause knowledge bottlenecks as they are unable to learn or adopt to new situations. While neural networks possess learning ability, they are computationally expensive. However, test results in recent neural network studies have demonstrated that they work well in a variety of loading conditions. Fuzzy logic techniques are used to accurately represent the operational constraints of power systems. Fuzzy logic has an advantage over other artificial intelligence techniques as it is able to remedy uncertainties in data. Evolutionary computing algorithms use probabilistic transition rules which can search complicated data to determine optimal constraints and parameters. Over 95 per cent of all papers published on power systems use genetic algorithms. It was concluded that hybrid systems using various artificial intelligence techniques are now being used by researchers. 69 refs.

  2. Compressed sensing approach for wrist vein biometrics.

    Science.gov (United States)

    Lantsov, Aleksey; Ryabko, Maxim; Shchekin, Aleksey

    2018-04-01

    The work describes features of the compressed sensing (CS) approach utilized for development of a wearable system for wrist vein recognition with single-pixel detection; we consider this system useful for biometrics authentication purposes. The CS approach implies use of a spatial light modulation (SLM) which, in our case, can be performed differently-with a liquid crystal display or diffusely scattering medium. We show that compressed sensing combined with above-mentioned means of SLM allows us to avoid using an optical system-a limiting factor for wearable devices. The trade-off between the 2 different SLM approaches regarding issues of practical implementation of CS approach for wrist vein recognition purposes is discussed. A possible solution of a misalignment problem-a typical issue for imaging systems based upon 2D arrays of photodiodes-is also proposed. Proposed design of the wearable device for wrist vein recognition is based upon single-pixel detection. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Improving the Outcome of Vein Grafts: Should Vascular Surgeons Turn Veins into Arteries?

    OpenAIRE

    Isaji, Toshihiko; Hashimoto, Takuya; Yamamoto, Kota; Santana, Jeans M.; Yatsula, Bogdan; Hu, Haidi; Bai, Hualong; Jianming, Guo; Kudze, Tambudzai; Nishibe, Toshiya; Dardik, Alan

    2017-01-01

    Autogenous vein grafts remain the gold standard conduit for arterial bypass, particularly for the treatment of critical limb ischemia. Vein graft adaptation to the arterial environment, i.e., adequate dilation and wall thickening, contributes to the superior performance of vein grafts. However, abnormal venous wall remodeling with excessive neointimal hyperplasia commonly causes vein graft failure. Since the PREVENT trials failed to improve vein graft outcomes, new strategies focus on the ada...

  4. Development of a hybrid system of artificial neural networks and ...

    African Journals Online (AJOL)

    Development of a hybrid system of artificial neural networks and artificial bee colony algorithm for prediction and modeling of customer choice in the market. ... attempted to present a new method for the modeling and prediction of customer choice in the market using the combination of artificial intelligence and data mining.

  5. Glucose Synthesis in a Protein-Based Artificial Photosynthesis System.

    Science.gov (United States)

    Lu, Hao; Yuan, Wenqiao; Zhou, Jack; Chong, Parkson Lee-Gau

    2015-09-01

    The objective of this study was to understand glucose synthesis of a protein-based artificial photosynthesis system affected by operating conditions, including the concentrations of reactants, reaction temperature, and illumination. Results from non-vesicle-based glyceraldehyde-3-phosphate (GAP) and glucose synthesis showed that the initial concentrations of ribulose-1,5-bisphosphate (RuBP) and adenosine triphosphate (ATP), lighting source, and temperature significantly affected glucose synthesis. Higher initial concentrations of RuBP and ATP significantly enhanced GAP synthesis, which was linearly correlated to glucose synthesis, confirming the proper functions of all catalyzing enzymes in the system. White fluorescent light inhibited artificial photosynthesis and reduced glucose synthesis by 79.2 % compared to in the dark. The reaction temperature of 40 °C was optimum, whereas lower or higher temperature reduced glucose synthesis. Glucose synthesis in the vesicle-based artificial photosynthesis system reconstituted with bacteriorhodopsin, F 0 F 1 ATP synthase, and polydimethylsiloxane-methyloxazoline-polydimethylsiloxane triblock copolymer was successfully demonstrated. This system efficiently utilized light-induced ATP to drive glucose synthesis, and 5.2 μg ml(-1) glucose was synthesized in 0.78-ml reaction buffer in 7 h. Light-dependent reactions were found to be the bottleneck of the studied artificial photosynthesis system.

  6. An artificial odor recognition system is developed for discriminating odors

    Directory of Open Access Journals (Sweden)

    Wisnu Jatmiko

    2002-12-01

    Full Text Available This artificial system consisted of 16 quartz resonator crystals as the sensor array, a frequency modulator and a frequency counter for each sensor that are connected directly to a microcomputer. We have already shown that the artificial odor recognition system with 4 sensors is high enough to discriminate simple odor correctly, however, when it was used to discriminate compound odors, the recognition capability of this system is dropped significantly to be about 40%. Results of experiments show that the developed artificial system with 16 sensors could discriminate compound aroma based on 6 gradient of alcohol concentrations with high recognition rate of 89.9% for non batch processing system, and 82.4% for batch processing of the classes of odors.

  7. Proactive learning for artificial cognitive systems

    Science.gov (United States)

    Lee, Soo-Young

    2010-04-01

    The Artificial Cognitive Systems (ACS) will be developed for human-like functions such as vision, auditory, inference, and behavior. Especially, computational models and artificial HW/SW systems will be devised for Proactive Learning (PL) and Self-Identity (SI). The PL model provides bilateral interactions between robot and unknown environment (people, other robots, cyberspace). For the situation awareness in unknown environment it is required to receive audiovisual signals and to accumulate knowledge. If the knowledge is not enough, the PL should improve by itself though internet and others. For human-oriented decision making it is also required for the robot to have self-identify and emotion. Finally, the developed models and system will be mounted on a robot for the human-robot co-existing society. The developed ACS will be tested against the new Turing Test for the situation awareness. The Test problems will consist of several video clips, and the performance of the ACSs will be compared against those of human with several levels of cognitive ability.

  8. Calcite veining and feeding conduits in a hydrothermal system: Insights from a natural section across the Pleistocene Gölemezli travertine depositional system (western Anatolia, Turkey)

    Science.gov (United States)

    Capezzuoli, Enrico; Ruggieri, Giovanni; Rimondi, Valentina; Brogi, Andrea; Liotta, Domenico; Alçiçek, Mehmet Cihat; Alçiçek, Hülya; Bülbül, Ali; Gandin, Anna; Meccheri, Marco; Shen, Chuan-Chou; Baykara, Mehmet Oruç

    2018-02-01

    Linking the architecture of structural conduits with the hydrothermal fluids migrating from the reservoir up to the surface is a key-factor in geothermal research. A contribution to this achievement derives from the study of spring-related travertine deposits, but although travertine depositional systems occur widely, their feeding conduits are only rarely exposed. The integrated study carried out in the geothermal Gölemezli area, nearby the well-known Pamukkale area (Denizli Basin, western Anatolia, Turkey), focused on onyx-like calcite veins (banded travertine) and bedded travertine well exposed in a natural cross-section allowing the reconstruction of the shallower part of a geothermal system. The onyx-like veins represent the thickest vein network (> 150 m) so far known. New field mapping and structural/kinematic analyses allowed to document a partially dismantled travertine complex (bedded travertine) formed by proximal fissure ridges and distal terraced/pools depositional systems. The banded calcite veins, WNW-trending and up to 12 m thick, developed within a > 200 m thick damaged rock volume produced by parallel fault zones. Th/U dating indicates a long lasting (middle-late Pleistocene) fluids circulation in a palaeo-geothermal system that, due to its location and chemical characteristics, can be considered the analogue of the nearby, still active, Pamukkale system. The isotopic characteristics of the calcite veins together with data from fluid inclusions analyses, allow the reconstruction of some properties (i.e. temperature, salinity and isotopic composition) and processes (i.e. temperature variation and intensity of degassing) that characterized the parent fluids and the relation between degassing intensity and specific microfabric of calcite crystals (elongated/microsparite-micrite bands), controlled by changes/fluctuations of the physico-chemical fluid characteristics.

  9. [Correlation between the width of lingual vein and the changes of hemodynamics of portal system in patients with primary liver cancer].

    Science.gov (United States)

    Yue, Xiao-Qiang; Gao, Jing-Dong; Zhai, Xiao-Feng; Liu, Qing; Jiang, Dong; Ling, Chang-Quan

    2006-09-01

    To explore the correlation between the width of lingual varix and changes of hemodynamics of portal system in patients with primary liver cancer so as to supply the data for the forecast of portal hypertension by observing lingual varix. The diameter of lingual vein (Dlv) was measured by vernier caliper as dependent variable, and the diameters and indexes of hemodynamics of portal vessels were measured by Doppler as independent variables, then a multipe stepwise analysis was performed. The diameters of portal vein (Dpv) and splenic vein (Dsv) entered the formula Dlv (mm) = 0.185 + 0.311 Dsv (mm) + 0.236 Dpv (mm) when the entry and removal values were alpha(in)=0.10 and alpha(out)=0.15, respectively. The width of lingual vein is closely correlated with the diameters of portal vein and splenic vein in patients with primary liver cancer.

  10. Role-based Rights in Artificial Social Systems

    NARCIS (Netherlands)

    G. Boella (Guido); L.W.N. van der Torre (Leon)

    2005-01-01

    htmlabstract In this paper we use normative systems to introduce roles and rights in the game-theoretic artificial social systems developed by Shoham and Tennenholtz. We model normative systems as socially constructed agents whose behavior is determined by a set of role playing agents. Roles are

  11. PHILOSOPHICAL AND ANTHROPOLOGICAL IMPORTANCE OF DEVELOPMENT OF ARTIFICIALLY CREATED INTELLIGENT SYSTEMS

    Directory of Open Access Journals (Sweden)

    Yu. D. Gensitskiy

    2015-12-01

    Full Text Available Purpose. Understanding the philosophical and anthropological importance of the development the artificial intelligence systems requires the analysis of the socio and anthropological content of intercomputer problems of interaction in the context of media philosophical praxis, anthropological maintenance of intellect nature, considering the specifics of the concept of artificial intelligence systems in the environment of M2M development of socio-cognitive practices of intercomputer interaction of social and humanitarian potential. Methodology. The implementation target is seen in the use of scientific and theoretical basis of the media philosophical, philosophical anthropology, the media philosophical approach to understanding society, science and technology, the use of publications on selected topics of research. Scientific novelty. The concept of artificial intelligence systems in the aspect of social and humanitarian potential of their formation and development in the environment of M2M was considered. The problems of machine learning as technology transformation M2M were analysed. The anthropological threats to the development of artificially created intelligent systems were defined. Conclusions. From the global risks point of view, one of the most critical circumstances due to the artificial intelligent system can strengthen its intelligence very quickly. The obvious reason for suspecting such an opportunity – a recursive self-improvement. Such system becomes smarter, including the intelligent writing of internal cognitive function, that the ability to rewrite their existing cognitive function to make it work better. This will make such systems more intelligent, and smarter in terms of the processing itself. The success of artificial intelligence may be the beginning of the end of the human race. Almost any technology falling into malicious hands reveals the potential for harm, but when it comes to artificial intelligent system, there is a

  12. Robust finger vein ROI localization based on flexible segmentation.

    Science.gov (United States)

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-10-24

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  13. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    Directory of Open Access Journals (Sweden)

    Dong Sun Park

    2013-10-01

    Full Text Available Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  14. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    Science.gov (United States)

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-01-01

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system. PMID:24284769

  15. Geochemistry and statistical analyses of porphyry system and epithermal veins at Hizehjan in northwestern Iran

    Directory of Open Access Journals (Sweden)

    Radmard Kaikhosrov

    2017-12-01

    Full Text Available Situated about 130 km northeast of Tabriz (northwest Iran, the Mazra’eh Shadi deposit is in the Arasbaran metallogenic belt (AAB. Intrusion of subvolcanic rocks, such as quartz monzodiorite-diorite porphyry, into Eocene volcanic and volcano-sedimentary units led to mineralisation and alteration. Mineralisation can be subdivided into a porphyry system and Au-bearing quartz veins within andesite and trachyandesite which is controlled by fault distribution. Rock samples from quartz veins show maximum values of Au (17100 ppb, Pb (21100 ppm, Ag (9.43ppm, Cu (611ppm and Zn (333 ppm. Au is strongly correlated with Ag, Zn and Pb. In the Au-bearing quartz veins, factor group 1 indicates a strong correlation between Au, Pb, Ag, Zn and W. Factor group 2 indicates a correlation between Cu, Te, Sb and Zn, while factor group 3 comprises Mo and As. Based on Spearman correlation coefficients, Sb and Te can be very good indicator minerals for Au, Ag and Pb epithermal mineralisation in the study area. The zoning pattern shows clearly that base metals, such as Cu, Pb, Zn and Mo, occur at the deepest levels, whereas Au and Ag are found at higher elevations than base metals in boreholes in northern Mazra’eh Shadi. This observation contrasts with the typical zoning pattern caused by boiling in epithermal veins. At Mazra’eh Shadi, quartz veins containing co-existing liquid-rich and vapour-rich inclusions, as strong evidence of boiling during hydrothermal evolution, have relatively high Au grades (up to 813 ppb. In the quartz veins, Au is strongly correlated with Ag, and these elements are in the same group with Fe and S. Mineralisation of Au and Ag is a result of pyrite precipitation, boiling of hydrothermal fluids and a pH decrease.

  16. Artificial light and quantum order in systems of screened dipoles

    International Nuclear Information System (INIS)

    Wen Xiaogang

    2003-01-01

    The origin of light is an unsolved mystery in nature. Recently, it was suggested that light may originate from a new kind of order, quantum order. To test this idea in experiments, we study systems of screened magnetic/electric dipoles in two-dimensional (2D) and 3D lattices. We show that our models contain an artificial light-a photonlike collective excitation. We discuss how to design realistic devices that realize our models. We show that the 'speed of light' and the 'fine-structure constant' of the artificial light can be tuned in our models. The properties of artificial atoms (bound states of pairs of artificial charges) are also discussed. The existence of artificial light (as well as artificial electron) in condensed-matter systems suggests that elementary particles, such as light and electron, may not be elementary. They may be collective excitations of quantum order in our vacuum. In our model, light is realized as a fluctuation of string-nets and charges as the ends of open strings (or nodes of string nets)

  17. Accessory hepatic vein: MR imaging

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Rho, Tack Soo; Cha, Sang Hoon; Park, Cheol Min; Cha, In Ho

    1995-01-01

    To evaluate the MR appearance of the accessory hepatic veins. The study included 87 consecutive patients for whom abdominal MR images were obtained. The subjects who had liver lesion or hepatic vascular abnormalities were excluded. Couinaud classified accessory hepatic veins into inferior and middle right hepatic veins. Our major interests were evaluation of the incidence, morphology, and location of the accessory hepatic vein. Inferior right hepatic vein was demonstrated in 43 out of 87 patients (49%). The morphology was linear in 35 patients (80.5%), and V-shaped in 8 patients (19.5%). In 40 patients (93%), the inferior right hepatic vein was located in the posteroinferior aspect of the right lobe. Middle right hepatic vein was demonstrated in 7 out of 87 patients (8%). All were single linear in morphology, combined with the inferior right hepatic vein, and located between the right hepatic vein and inferior right hepatic vein. The accessory hepatic vein was demonstrated in 49% among the Korean adult population, and was located in posteroinferior portion of the liver, in 93%

  18. Emergent Properties in Natural and Artificial Dynamical Systems

    CERN Document Server

    Aziz-Alaoui, M.A

    2006-01-01

    An important part of the science of complexity is the study of emergent properties arising through dynamical processes in various types of natural and artificial systems. This is the aim of this book, which is the outcome of a discussion meeting within the first European conference on complex systems. It presents multidisciplinary approaches for getting representations of complex systems and using different methods to extract emergent structures. This carefully edited book studies emergent features such as self organization, synchronization, opening on stability and robustness properties. Invariant techniques are presented which can express global emergent properties in dynamical and in temporal evolution systems. This book demonstrates how artificial systems such as a distributed platform can be used for simulation used to search emergent placement during simulation execution.

  19. Renal vein to renal collecting system fistula: An extreme complication from central venous thrombosis secondary to indwelling catheter

    Directory of Open Access Journals (Sweden)

    Aditya Safaya

    2018-04-01

    Full Text Available Central venous catheters are routinely used for resuscitation, chemotherapy and nutrition but are not without risk. Central lines are the most common extrinsic cause of venous thrombosis in neonates and infants. We present an ex-36 week 1800g infant baby girl recovering after a staged repair of gastroschisis with ileostomy and mucous fistula formation. The patient was receiving parenteral nutrition through an indwelling saphenous vein tunneled catheter, with its tip in the inferior vena cava. The patient developed polyuria, with a characteristic odor of the parenteral nutrition and a urine analysis showed glucose and triglyceride levels consistent with the composition of the parenteral nutrition fluid. A fluoroscopic cysto-urogram and an inferior vena-cavogram showed a catheter-associated inferior vena cava thrombosis leading to backpressure changes, diverting all intravenous contrast into the right renal vein and to renal collecting system, thus elucidating the route of the parenteral nutrition fluid reaching the bladder. Our case represents an extreme case of complicated central venous thrombosis. We emphasize the importance of practicing a high index of suspicion for thrombotic complications in severely ill neonates with central venous access. An early diagnosis and aggressive management may prevent progression of the disease towards an overwhelming complication. Keywords: Central venous catheterization complications, Renal vein-collecting system connection, Renal vein- collecting system fistula

  20. Nonintrusive Finger-Vein Recognition System Using NIR Image Sensor and Accuracy Analyses According to Various Factors

    Directory of Open Access Journals (Sweden)

    Tuyen Danh Pham

    2015-07-01

    Full Text Available Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

  1. Nonintrusive Finger-Vein Recognition System Using NIR Image Sensor and Accuracy Analyses According to Various Factors.

    Science.gov (United States)

    Pham, Tuyen Danh; Park, Young Ho; Nguyen, Dat Tien; Kwon, Seung Yong; Park, Kang Ryoung

    2015-07-13

    Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

  2. Anatomy of the Portal Vein Bifurcation: Implication for Transjugular Intrahepatic Portal Systemic Shunts

    International Nuclear Information System (INIS)

    Kwok, Philip Chong-hei; Ng, Wai Fu; Lam, Christine Suk-yee; Tsui, Polly Po; Faruqi, Asma

    2003-01-01

    Purpose: The relationship of the portalvein bifurcation to the liver capsule in Asians, which is an important landmark for transjugular intrahepatic portosystemic shunt, has not previously been described. Methods: The anatomy of the portal vein bifurcation was studied in 70 adult Chinese cadavers; it was characterized as intrahepatic or extrahepatic. The length of the exposed portion of the right and left portal veins was measured when the bifurcation was extrahepatic. Results: The portal vein bifurcation was intrahepatic in 37 cadavers (53%) and extrahepatic in 33 cadavers (47%). The mean length of the right and left extrahepatic portal veins was 0.96 cm and 0.85 cm respectively.Both were less than or equal to 2 cm in 94% of the cadavers with extrahepatic bifurcation. There was no correlation between the presence of cirrhosis and the location of the portal vein bifurcation(p 1.0). There was no statistically significant difference in liver mass in cadavers with either extrahepatic or intrahepatic bifurcation (p =0.40). Conclusions: These findings suggest that fortransjugular intrahepatic portosystemic shunt placement, a portal vein puncture 2 cm from the bifurcation will be safe in most cases

  3. QUESTION ANSWERING SYSTEM BERBASIS ARTIFICIAL INTELLIGENCE MARKUP LANGUAGE SEBAGAI MEDIA INFORMASI

    Directory of Open Access Journals (Sweden)

    Fajrin Azwary

    2016-04-01

    Full Text Available Artificial intelligence technology nowadays, can be processed with a variety of forms, such as chatbot, and the various methods, one of them using Artificial Intelligence Markup Language (AIML. AIML using template matching, by comparing the specific patterns in the database. AIML template design process begins with determining the necessary information, then formed into questions, these questions adapted to AIML pattern. From the results of the study, can be known that the Question-Answering System in the chatbot using Artificial Intelligence Markup Language are able to communicate and deliver information. Keywords: Artificial Intelligence, Template Matching, Artificial Intelligence Markup Language, AIML Teknologi kecerdasan buatan saat ini dapat diolah dengan berbagai macam bentuk, seperti ChatBot, dan berbagai macam metode, salah satunya menggunakan Artificial Intelligence Markup Language (AIML. AIML menggunakan metode template matching yaitu dengan membandingkan pola-pola tertentu pada database. Proses perancangan template AIML diawali dengan menentukan informasi yang diperlukan, kemudian dibentuk menjadi pertanyaan, pertanyaan tersebut disesuaikan dengan bentuk pattern AIML. Hasil penelitian dapat diperoleh bahwa Question-Answering System dalam bentuk ChatBot menggunakan Artificial Intelligence Markup Language dapat berkomunikasi dan menyampaikan informasi. Kata kunci : Kecerdasan Buatan, Pencocokan Pola, Artificial Intelligence Markup Language, AIML

  4. An Artificial Neural Network Controller for Intelligent Transportation Systems Applications

    Science.gov (United States)

    1996-01-01

    An Autonomous Intelligent Cruise Control (AICC) has been designed using a feedforward artificial neural network, as an example for utilizing artificial neural networks for nonlinear control problems arising in intelligent transportation systems appli...

  5. Varicose Veins - Multiple Languages

    Science.gov (United States)

    ... Concerns and Discomforts of Pregnancy: Varicose Veins - English MP3 Concerns and Discomforts of Pregnancy: Varicose Veins - 简体中文 (Chinese, Simplified (Mandarin dialect)) MP3 Concerns and Discomforts of Pregnancy: Varicose Veins - English ...

  6. Valsalva and gravitational variability of the internal jugular vein and common femoral vein: Ultrasound assessment

    Energy Technology Data Exchange (ETDEWEB)

    Beddy, P. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland)]. E-mail: pbeddy@eircom.net; Geoghegan, T. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Ramesh, N. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Buckley, O. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); O' Brien, J. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Colville, J. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Torreggiani, W.C. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland)

    2006-05-15

    Purpose: Central venous cannulation via the common femoral vein is an important starting point for many interventions. The purpose of this study was to determine the optimum conditions for cannulation of the femoral vein and to compare these with the relative changes in the internal jugular vein. Methods: High-resolution 2D ultrasound was utilised to determine variability of the calibre of the femoral and internal jugular veins in 10 healthy subjects. Venous diameter was assessed during the Valsalva manoeuvre and in different degrees of the Trendelenburg position. Results: The Valsalva manoeuvre significantly increased the size of the femoral and internal jugular veins. There was a relatively greater increase in femoral vein diameter when compared with the internal jugular vein of 40 and 29%, respectively. Changes in body inclination (Trendelenburg position) did not significantly alter the luminal diameter of the femoral vein. However, it significantly increased internal jugular vein diameter. Conclusions: Femoral vein cannulation is augmented by the Valsalva manoeuvre but not significantly altered by the gravitational position of the subject.

  7. A Characterization of the Utility of Using Artificial Intelligence to Test Two Artificial Intelligence Systems

    OpenAIRE

    Straub, Jeremy; Huber, Justin

    2013-01-01

    An artificial intelligence system, designed for operations in a real-world environment faces a nearly infinite set of possible performance scenarios. Designers and developers, thus, face the challenge of validating proper performance across both foreseen and unforeseen conditions, particularly when the artificial intelligence is controlling a robot that will be operating in close proximity, or may represent a danger, to humans. While the manual creation of test cases allows limited testing (p...

  8. [Baroreflexes originated in vertebral artery zones upon peripheral vein tonus, systemic arterial blood pressure, and external respiration].

    Science.gov (United States)

    Agadzhanian, N A; Kupriianov, S V

    2008-06-01

    The investigation was intended to study the role ofbaroreceptors ofhemodynamically isolated zone of vertebral arteries in regulation of peripheral veins tonus, arterial pressure and external respiration. Pressure decrease in this vascular reflexogenic zone led to reflex responses of increase in femoral vein tonus, elevation of blood pressure level and stimulation of external respiration. The opposite reflex responses of cardio-respiratory functional system to initial pressure activation of vertebral arteries baroreceptors are observed. Basing on generalization of our own findings and similar physiological and morphological researches of other authors, it is established that afferentation from the vertebral artery zone is a reflexogenic factor of somatic muscles' veins tonus regulation. These reflexes of capacity vessels tonic activity changes are part of cardio-respiratory responses of maintaining the tissue gaseous exchange.

  9. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  10. EU copyright protection of works created by artificial intelligence systems

    OpenAIRE

    Bøhler, Helene Margrethe

    2017-01-01

    This thesis is concerned with copyright regulation of works created by artificial intelligence systems. The rapid advances in artificial intelligence are calling into question some of the fundamental assumptions upon which intellectual property law rests. Currently, the European framework of copyright law does not take non-human innovation into account. Meanwhile, advances in artificial intelligence are quickly making machine-generation of creative works a reality. Institutions of the Europea...

  11. Artificial immune system applications in computer security

    CERN Document Server

    Tan, Ying

    2016-01-01

    This book provides state-of-the-art information on the use, design, and development of the Artificial Immune System (AIS) and AIS-based solutions to computer security issues. Artificial Immune System: Applications in Computer Security focuses on the technologies and applications of AIS in malware detection proposed in recent years by the Computational Intelligence Laboratory of Peking University (CIL@PKU). It offers a theoretical perspective as well as practical solutions for readers interested in AIS, machine learning, pattern recognition and computer security. The book begins by introducing the basic concepts, typical algorithms, important features, and some applications of AIS. The second chapter introduces malware and its detection methods, especially for immune-based malware detection approaches. Successive chapters present a variety of advanced detection approaches for malware, including Virus Detection System, K-Nearest Neighbour (KNN), RBF networ s, and Support Vector Machines (SVM), Danger theory, ...

  12. Cognitive logical systems with artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Liss, E

    1983-09-01

    The simulation of cognitive processes for the purpose of the technical development of learning systems with intelligent behavior is a basic object of the young interdisciplinary cognition science which is based upon artificial intelligence, cognitive psychology, computer science, linguistics and pedagogics. Cognitive systems may be described as knowledge-based logical systems. Based on structural and functional principles of intelligent automata and elementary information processing systems with structural learning capability the future process, machine and robot controls, advising units and fifth generation computers may be developed.

  13. Further substantial improvement of interventional diagnosis and treatment via portal vein system

    International Nuclear Information System (INIS)

    Yang Weizhu; Chen Yongde

    2006-01-01

    Along with the development of interventional appliances and proficiency of operational skills, the interventional diagnosis and treatment via hepatic portal vein system have achieved great progress and improvement. However, in order to further exploit the advantages of interventional diagnosis and treatment, the review of the anatomical structures, normal aberrance of portal venous system were needed. Getting familiar with pathologic condition to discover the new interventional appliances and embolic agents, and then in term of conduct the research on a very tough substantial base in a down-to-earth manner were important. (authors)

  14. Observation of portal circulation through superior mesenteric vein by enteric coated capsule of thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Norihisa; Nakajima, Kenichi; Watanabe, Naoto; Seto, Mikito; Yokoyama, Kunihiko; Shuke, Noriyuki; Michigishi, Takatoshi; Takayama, Teruhiko; Aburano, Tamio; Hisada, Kinichi

    1988-06-01

    A new method of oral administration of an enteric coated capsule of /sup 201/Tl (/sup 201/Tl-capsule) was developed to evaluate the portal circulation through the superior mesenteric vein (SMV). The /sup 201/Tl-capsule was not collapsed in the artificial gastric juice, whereas it melted soon after soaking in the artificial intestinal juice. In a clinical trial of 42 cases, /sup 201/Tl was satisfactory released in the duodenum in 36 cases where clear liver images were observed except in 1 patient. Heart to liver ratio (HL) at 60 or 90 min after duodenal release of /sup 201/Tl was 0.32+-0.07 (mean +-1 s.d.) in normal controls, 0.34+-0.12 in chronic hepatitis, 0.31+-0.12 in acute hepatitis, 0.45+-0.13 in liver cirrhosis and 0.48+-0.32 in cirrhosis with hepatocellular carcinoma. In 11 patients who had both oral and rectal studies with /sup 201/Tl, 7 showed a high HL ratio of more than 0.8 in the rectal study but only 1 showed a similarly high ratio of 1.07 in the oral study. In the group of varied liver disorders we have studied so far, it was found that most of the SMV blood flowed into the liver and the degree of portal systemic shunting (PSS) from the SMV was much smaller compared to that from the inferior mesenteric vein. The present study with oral administration of the /sup 201/Tl-capsule was of value in understanding portal circulation through the SMV, however, this technique seemed of limited usefulness for evaluating overall pathologic PSS.

  15. Observation of portal circulation through superior mesenteric vein by enteric coated capsule of thallium-201

    International Nuclear Information System (INIS)

    Tonami, Norihisa; Nakajima, Kenichi; Watanabe, Naoto; Seto, Mikito; Yokoyama, Kunihiko; Shuke, Noriyuki; Michigishi, Takatoshi; Takayama, Teruhiko; Aburano, Tamio; Hisada, Kinichi; Tanaka, Nobuyoshi; Kobayashi, Kenichi

    1988-01-01

    A new method of oral administration of an enteric coated capsule of 201 Tl ( 201 Tl-capsule) was developed to evaluate the portal circulation through the superior mesenteric vein (SMV). The 201 Tl-capsule was not collapsed in the artificial gastric juice, whereas it melted soon after soaking in the artificial intestinal juice. In a clinical trial of 42 cases, 201 Tl was satisfactory released in the duodenum in 36 cases where clear liver images were observed except in 1 patient. Heart to liver ratio (H/L) at 60 or 90 min after duodenal release of 201 Tl was 0.32±0.07 (mean ±1 s.d.) in normal controls, 0.34±0.12 in chronic hepatitis, 0.31±0.12 in acute hepatitis, 0.45±0.13 in liver cirrhosis and 0.48±0.32 in cirrhosis with hepatocellular carcinoma. In 11 patients who had both oral and rectal studies with 201 Tl, 7 showed a high H/L ratio of more than 0.8 in the rectal study but only 1 showed a similarly high ratio of 1.07 in the oral study. In the group of varied liver disorders we have studied so far, it was found that most of the SMV blood flowed into the liver and the degree of portal systemic shunting (PSS) from the SMV was much smaller compared to that from the inferior mesenteric vein. The present study with oral administration of the 201 Tl-capsule was of value in understanding portal circulation through the SMV, however, this technique seemed of limited usefulness for evaluating overall pathologic PSS. (orig.)

  16. Sliding Window-Based Region of Interest Extraction for Finger Vein Images

    Science.gov (United States)

    Yang, Lu; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2013-01-01

    Region of Interest (ROI) extraction is a crucial step in an automatic finger vein recognition system. The aim of ROI extraction is to decide which part of the image is suitable for finger vein feature extraction. This paper proposes a finger vein ROI extraction method which is robust to finger displacement and rotation. First, we determine the middle line of the finger, which will be used to correct the image skew. Then, a sliding window is used to detect the phalangeal joints and further to ascertain the height of ROI. Last, for the corrective image with certain height, we will obtain the ROI by using the internal tangents of finger edges as the left and right boundary. The experimental results show that the proposed method can extract ROI more accurately and effectively compared with other methods, and thus improve the performance of finger vein identification system. Besides, to acquire the high quality finger vein image during the capture process, we propose eight criteria for finger vein capture from different aspects and these criteria should be helpful to some extent for finger vein capture. PMID:23507824

  17. Analyze of the Measuring Performance for Artificially Business Intelligent Systems

    OpenAIRE

    Vatuiu, Teodora

    2007-01-01

    This paper analyzes the measuring performance of artificially business intelligent systems. Thousands of persons-years have been devoted to the research and development in the vari¬ous aspects of artificially intelligent systems. Much progress has been attained. However, there has been no means of evaluating the progress of the field. How can we assess the cur¬rent state of the science? Most of business intelligent systems are beginning to be deployed commercially. How can a commercial buyer ...

  18. Petrology, chronology and sequence of vein systems: Systematic magmatic and hydrothermal history of a major intracontinental shear zone, Canadian Appalachians

    Science.gov (United States)

    Pe-Piper, Georgia; Piper, David J. W.; McFarlane, Chris R. M.; Sangster, Chris; Zhang, Yuanyuan; Boucher, Brandon

    2018-04-01

    Intra-continental shear zones developed during continental collision may experience prolonged magmatism and mineralization. The Cobequid Shear Zone formed part of a NE-SW-trending, orogen-parallel shear system in the late Devonian-early Carboniferous, where syn-tectonic granite-gabbro plutons and volcanic rocks 4 km thick were progressively deformed. In late Carboniferous to Permian, Alleghanian collision of Africa with Laurentia formed the E-W trending Minas Fault Zone, reactivating parts of the Cobequid Shear Zone. The 50 Ma history of hydrothermal mineralization following pluton emplacement is difficult to resolve from field relationships of veins, but SEM study of thin sections provides clear detail on the sequence of mineralization. The general paragenesis is: albite ± quartz ± chlorite ± monazite → biotite → calcite, allanite, pyrite → Fe-carbonates, Fe-oxides, minor sulfides, calcite and synchysite. Chronology was determined from literature reports and new U-Pb LA-ICPMS dating of monazite and allanite in veins. Vein mineralization was closely linked to magmatic events. Vein emplacement occurred preferentially during fault movement recognised from basin-margin inversion, as a result of fractures opening in the damage zone of master faults. The sequence of mineralization, from ca. 355 Ma riebeckite and albite veins to ca. 327 (-305?) Ma siderite-magnetite and sulfide mineralization, resembles Precambrian iron-oxide-copper-gold (IOCG) systems in the literature. The abundant magmatic Na, halogens and CO2 in veins and some magmatic bodies, characteristic of IOCG systems, were derived from the deeply subducted Rheic Ocean slab with little terrigenous sediment. Regional extension of the Magdalen Basin caused asthenospheric upwelling and melting of the previously metasomatized sub-continental lithospheric mantle. Crustal scale strike-slip faulting facilitated the rise of magmas, resulting in high heat flow driving an active hydrothermal system. Table S2

  19. The application of hybrid artificial intelligence systems for forecasting

    Science.gov (United States)

    Lees, Brian; Corchado, Juan

    1999-03-01

    The results to date are presented from an ongoing investigation, in which the aim is to combine the strengths of different artificial intelligence methods into a single problem solving system. The premise underlying this research is that a system which embodies several cooperating problem solving methods will be capable of achieving better performance than if only a single method were employed. The work has so far concentrated on the combination of case-based reasoning and artificial neural networks. The relative merits of artificial neural networks and case-based reasoning problem solving paradigms, and their combination are discussed. The integration of these two AI problem solving methods in a hybrid systems architecture, such that the neural network provides support for learning from past experience in the case-based reasoning cycle, is then presented. The approach has been applied to the task of forecasting the variation of physical parameters of the ocean. Results obtained so far from tests carried out in the dynamic oceanic environment are presented.

  20. Comparison between mechanical properties of human saphenous vein and umbilical vein

    Directory of Open Access Journals (Sweden)

    Hamedani Borhan

    2012-08-01

    Full Text Available Abstract Background As a main cause of mortality in developed countries, Coronary Artery Disease (CAD is known as silent killer with a considerable cost to be dedicated for its treatment. Coronary Artery Bypass Graft (CABG is a common remedy for CAD for which different blood vessels are used as a detour. There is a lack of knowledge about mechanical properties of human blood vessels used for CABG, and while these properties have a great impact on long-term patency of a CABG. Thus, studying these properties, especially those of human umbilical veins which have not been considered yet, looks utterly necessary. Methods Umbilical vein, as well as human Saphenous vein, are respectively obtained after cesarean and CABG. First, histological tests were performed to investigate different fiber contents of the samples. Having prepared samples carefully, force-displacement results of samples were rendered to real stress–strain measurements and then a fourth-order polynomial was used to prove the non-linear behavior of these two vessels. Results Results were analyzed in two directions, i.e. circumferentially and longitudinally, which then were compared with each other. The comparison between stiffness and elasticity of these veins showed that Saphenous vein’s stiffness is much higher than that of umbilical vein and also, it is less stretchable. Furthermore, for both vessels, longitudinal stiffness was higher than that of circumferential and in stark contrast, stretch ratio in circumferential direction came much higher than longitudinal orientation. Conclusion Blood pressure is very high in the region of aorta, so there should be a stiff blood vessel in this area and previous investigations showed that stiffer vessels would have a better influence on the flow of bypass. To this end, the current study has made an attempt to compare these two blood vessels’ stiffness, finding that Saphenous vein is stiffer than umbilical vein which is somehow as stiff as

  1. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  2. Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.

    Science.gov (United States)

    White, R N; Parry, A T

    2016-05-01

    To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.

  3. Convolutional Neural Network-Based Finger-Vein Recognition Using NIR Image Sensors.

    Science.gov (United States)

    Hong, Hyung Gil; Lee, Min Beom; Park, Kang Ryoung

    2017-06-06

    Conventional finger-vein recognition systems perform recognition based on the finger-vein lines extracted from the input images or image enhancement, and texture feature extraction from the finger-vein images. In these cases, however, the inaccurate detection of finger-vein lines lowers the recognition accuracy. In the case of texture feature extraction, the developer must experimentally decide on a form of the optimal filter for extraction considering the characteristics of the image database. To address this problem, this research proposes a finger-vein recognition method that is robust to various database types and environmental changes based on the convolutional neural network (CNN). In the experiments using the two finger-vein databases constructed in this research and the SDUMLA-HMT finger-vein database, which is an open database, the method proposed in this research showed a better performance compared to the conventional methods.

  4. DEVELOPING A HUMAN CONTROLLED MODEL FOR SAFE ARTIFICIAL INTELLIGENCE SYSTEMS

    OpenAIRE

    KÖSE, Utku

    2018-01-01

    Artificial Intelligence is known as one of the most effective research field of nowadays and the future. But rapid rise of Artificial Intelligence and its potential to solve all real world problems autonomously, it has caused also several anxieties. Some scientists think that intelligent systems can reach to a level, which is dangerous for the humankind so because of that some precautions should be taken. So, many sub-research fields like Machine Ethics or Artificial Intelligence Safety have ...

  5. Kinetic parametric estimation in animal PET molecular imaging based on artificial immune network

    International Nuclear Information System (INIS)

    Chen Yuting; Ding Hong; Lu Rui; Huang Hongbo; Liu Li

    2011-01-01

    Objective: To develop an accurate,reliable method without the need of initialization in animal PET modeling for estimation of the tracer kinetic parameters based on the artificial immune network. Methods: The hepatic and left ventricular time activity curves (TACs) were obtained by drawing ROIs of liver tissue and left ventricle on dynamic 18 F-FDG PET imaging of small mice. Meanwhile, the blood TAC was analyzed by sampling the tail vein blood at different time points after injection. The artificial immune network for parametric optimization of pharmacokinetics (PKAIN) was adapted to estimate the model parameters and the metabolic rate of glucose (K i ) was calculated. Results: TACs of liver,left ventricle and tail vein blood were obtained.Based on the artificial immune network, K i in 3 mice was estimated as 0.0024, 0.0417 and 0.0047, respectively. The average weighted residual sum of squares of the output model generated by PKAIN was less than 0.0745 with a maximum standard deviation of 0.0084, which indicated that the proposed PKAIN method can provide accurate and reliable parametric estimation. Conclusion: The PKAIN method could provide accurate and reliable tracer kinetic modeling in animal PET imaging without the need of initialization of model parameters. (authors)

  6. A review of the anatomy and clinical significance of adrenal veins.

    Science.gov (United States)

    Cesmebasi, Alper; Du Plessis, Maira; Iannatuono, Mark; Shah, Sameer; Tubbs, R Shane; Loukas, Marios

    2014-11-01

    The adrenal veins may present with a multitude of anatomical variants, which surgeons must be aware of when performing adrenalectomies. The adrenal veins originate during the formation of the prerenal inferior vena cava (IVC) and are remnants of the caudal portion of the subcardinal veins, cranial to the subcardinal sinus in the embryo. The many communications between the posterior cardinal, supracardinal, and subcardinal veins of the primordial venous system provide an explanation for the variable anatomy. Most commonly, one central vein drains each adrenal gland. The long left adrenal vein joins the inferior phrenic vein and drains into the left renal vein, while the short right adrenal vein drains immediately into the IVC. Multiple variations exist bilaterally and may pose the risk of surgical complications. Due to the potential for collaterals and accessory adrenal vessels, great caution must be taken during an adrenalectomy. Adrenal venous sampling, the gold standard in diagnosing primary hyperaldosteronism, also requires the clinician to have a thorough knowledge of the adrenal vein anatomy to avoid iatrogenic injury. The adrenal vein acts as an important conduit in portosystemic shunts, thus the nature of the anatomy and hypercoagulable states pose the risk of thrombosis. © 2014 Wiley Periodicals, Inc.

  7. Distributed Computations Environment Protection Using Artificial Immune Systems

    Directory of Open Access Journals (Sweden)

    A. V. Moiseev

    2011-12-01

    Full Text Available In this article the authors describe possibility of artificial immune systems applying for distributed computations environment protection from definite types of malicious impacts.

  8. Endovascular Radiofrequency Ablation for Varicose Veins

    Science.gov (United States)

    2011-01-01

    treatment plan. The RFA procedure involves the introduction of a guide wire into the target vein under ultrasound guidance followed by the insertion of an introducer sheath through which the RFA catheter is advanced. Once satisfactory positioning has been confirmed with ultrasound, a tumescent anaesthetic solution is injected into the soft tissue surrounding the target vein along its entire length. This serves to anaesthetize the vein, insulate the heat from damaging adjacent structures, including nerves and skin and compresses the vein increasing optimal contact of the vessel wall with the electrodes or expanded prongs of the RF device. The RF generator is then activated and the catheter is slowly pulled along the length of the vein. At the end of the procedure, hemostasis is then achieved by applying pressure to the vein entry point. Adequate and proper compression stockings and bandages are applied after the procedure to reduce the risk of venous thromboembolism and to reduce postoperative bruising and tenderness. Patients are encouraged to walk immediately after the procedure. Follow-up protocols vary, with most patients returning 1 to 3 weeks later for an initial follow-up visit. At this point, the initial clinical result is assessed and occlusion of the treated vessels is confirmed with ultrasound. Patients often have a second follow-up visit 1 to 3 months following RFA at which time clinical evaluation and ultrasound are repeated. If required, additional procedures such as phlebectomy or sclerotherapy may be performed during the RFA procedure or at any follow-up visits. Regulatory Status The Closure System® radiofrequency generator for endovascular thermal ablation of varicose veins was approved by Health Canada as a class 3 device in March 2005, registered under medical device license 67865. The RFA intravascular catheter was approved by Health Canada in November 2007 for the ClosureFast catheter, registered under medical device license 16574. The Closure System

  9. Absence of Middle Hepatic Vein Combined with Retro-Aortic Left Renal Vein: a Very Rare Case Report

    Directory of Open Access Journals (Sweden)

    Sezer Akçer

    2012-06-01

    Full Text Available The hepatic and renal veins drain into the inferior vena cava. The upper group of hepatic veins consists of three veins which extend to the posterior face of the liver to join the inferior cava. The left renal vein passes anterior to the aorta just below the origin of the superior mesenteric artery. We detected a variation in the hepatic and renal veins in a multislice CT angiogram of a nine-year-old male patient in the Radiology Department of Afyon Kocatepe University Medical School. The upper group hepatic veins normally drains into the inferior vena cava as three separate trunks, namely the right, left and middle. In our case, we found that only the right and left hepatic veins existed and the middle hepatic vein was absent. Furthermore, the left renal vein, which normally passes anterior to the abdominal aorta, was retro-aortic. Left renal vein variations are of great importance in planning retroperitoneal surgery and vascular interventions. Knowledge of a patient’s hepatic vein and renovascular anatomy and determining their variations and anomalies are of critical importance to abdominal operations, transplantations and preoperative evaluation of endovascular interventions.

  10. Research and implementation of finger-vein recognition algorithm

    Science.gov (United States)

    Pang, Zengyao; Yang, Jie; Chen, Yilei; Liu, Yin

    2017-06-01

    In finger vein image preprocessing, finger angle correction and ROI extraction are important parts of the system. In this paper, we propose an angle correction algorithm based on the centroid of the vein image, and extract the ROI region according to the bidirectional gray projection method. Inspired by the fact that features in those vein areas have similar appearance as valleys, a novel method was proposed to extract center and width of palm vein based on multi-directional gradients, which is easy-computing, quick and stable. On this basis, an encoding method was designed to determine the gray value distribution of texture image. This algorithm could effectively overcome the edge of the texture extraction error. Finally, the system was equipped with higher robustness and recognition accuracy by utilizing fuzzy threshold determination and global gray value matching algorithm. Experimental results on pairs of matched palm images show that, the proposed method has a EER with 3.21% extracts features at the speed of 27ms per image. It can be concluded that the proposed algorithm has obvious advantages in grain extraction efficiency, matching accuracy and algorithm efficiency.

  11. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Schellhammer, Frank; Esch, Jan Schulte am; Hammerschlag, Sascha; Knoefel, Wolfram Trudo; Fuerst, Guenter

    2008-01-01

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  12. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  13. LOCAL LINE BINARY PATTERN FOR FEATURE EXTRACTION ON PALM VEIN RECOGNITION

    Directory of Open Access Journals (Sweden)

    Jayanti Yusmah Sari

    2015-08-01

    Full Text Available In recent years, palm vein recognition has been studied to overcome problems in conventional systems in biometrics technology (finger print, face, and iris. Those problems in biometrics includes convenience and performance. However, due to the clarity of the palm vein image, the veins could not be segmented properly. To overcome this problem, we propose a palm vein recognition system using Local Line Binary Pattern (LLBP method that can extract robust features from the palm vein images that has unclear veins. LLBP is an advanced method of Local Binary Pattern (LBP, a texture descriptor based on the gray level comparison of a neighborhood of pixels. There are four major steps in this paper, Region of Interest (ROI detection, image preprocessing, features extraction using LLBP method, and matching using Fuzzy k-NN classifier. The proposed method was applied on the CASIA Multi-Spectral Image Database. Experimental results showed that the proposed method using LLBP has a good performance with recognition accuracy of 97.3%. In the future, experiments will be conducted to observe which parameter that could affect processing time and recognition accuracy of LLBP is needed

  14. Biometric identification using infrared dorsum hand vein images

    Directory of Open Access Journals (Sweden)

    Óscar Fernando Motato Toro

    2009-01-01

    Full Text Available The evident need for improving access and safety controls has orientated the development of new personal identification systems towards using biometric, physiological and behavioral features guaranteeing increasing greater levels of performance. Motivated by this trend, the development and implementation of a computational tool for recording and validating people’s identity using dorsum hand vein images is presented here. A low-cost hardware module for acquiring infrared images was thus designed; it consisted of a conventional video-camera, optical lenses, controlled infrared illumination sources and a frame grabber. The accompanying software module was concerned with visualizing and capturing images, selecting regions of interest, pattern seg-mentation in the region and extracting, describing and classifying these features. An artificial neuron network approach was im-plemented for pattern recognition, resulting in it proving the biometric indicator to be sufficiently discriminating, and a corre-lation-based approach using a 100 image database for static characterisation, determined the system’s maximum efficiency to be 95.72% at a threshold equal to 65. False acceptance rate (FAR was 8.57% and false rejection rate (FRR was 0% at this threshold.

  15. The anterior medullary-anterior pontomesencephalic venous system and its bridging veins communicating to the dural sinuses: normal anatomy and drainage routes from dural arteriovenous fistulas

    International Nuclear Information System (INIS)

    Kiyosue, Hiro; Tanoue, Shuichi; Sagara, Yoshiko; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu; Hori, Yuzo; Nagatomi, Hirofumi

    2008-01-01

    We evaluated the normal venous anatomy of the anterior medullary/anterior pontomesencephalic venous (AMV/APMV) system and bridging veins connected to the dural sinuses using magnetic resonance (MR) imaging and demonstrated cases of dural arteriovenous fistulas (DAVFs) with bridging venous drainage. MR images obtained using a 3D gradient echo sequence in 70 patients without lesions affecting the deep or posterior venous channels were reviewed to evaluate the normal anatomy of the AMV/APMV system and bridging veins. MR images and digital subtraction angiography in 80 cases with intracranial or craniocervical junction DAVFs were reviewed to evaluate the bridging venous drainage from DAVFs. MR images clearly revealed AMV/APMV in 35 cases. Fifteen cases showed a direct connection between AMV and APMV, while 15 cases showed an indirect communication via the transverse pontine vein or the bridging vein. In the five remaining cases, the AMV and APMV end separately to the bridging vein or the transverse pontine vein. Bridging veins were identified in 34 cases, connecting to the cavernous sinus in 33, to the suboccipital cavernous sinus in 11, and the inferior petrosal sinus in five cases. In 80 DAVF cases, seven of 40 cavernous sinus DAVFs, two craniocervical junction DAVFs, and one inferior petrosal sinus DAVF drained via bridging veins to the brain stem. The AMV/APMV and bridging veins showed various anatomies and frequently showed a connection to the cavernous sinus. Knowledge of the venous anatomy is helpful for the diagnosis and intravascular treatment of DAVFs. (orig.)

  16. Geology of the epithermal Ag-Au Huevos Verdes vein system and San José district, Deseado massif, Patagonia, Argentina

    Science.gov (United States)

    Dietrich, Andreas; Gutierrez, Ronald; Nelson, Eric P.; Layer, Paul W.

    2012-03-01

    The San José district is located in the northwest part of the Deseado massif and hosts a number of epithermal Ag-Au quartz veins of intermediate sulfidation style, including the Huevos Verdes vein system. Veins are hosted by andesitic rocks of the Bajo Pobre Formation and locally by rhyodacitic pyroclastic rocks of the Chon Aike Formation. New 40Ar/39Ar constraints on the age of host rocks and mineralization define Late Jurassic ages of 151.3 ± 0.7 Ma to 144.7 ± 0.1 Ma for volcanic rocks of the Bajo Pobre Formation and of 147.6 ± 1.1 Ma for the Chon Aike Formation. Illite ages of the Huevos Verdes vein system of 140.8 ± 0.2 and 140.5 ± 0.3 Ma are 4 m.y. younger than the volcanic host rock unit. These age dates are among the youngest reported for Jurassic volcanism in the Deseado massif and correlate well with the regional context of magmatic and hydrothermal activity. The Huevos Verdes vein system has a strike length of 2,000 m, with several ore shoots along strike. The vein consists of a pre-ore stage and three main ore stages. Early barren quartz and chalcedony are followed by a mottled quartz stage of coarse saccharoidal quartz with irregular streaks and discontinuous bands of sulfide-rich material. The banded quartz-sulfide stage consists of sulfide-rich bands alternating with bands of quartz and bands of chlorite ± illite. Late-stage sulfide-rich veinlets are associated with kaolinite gangue. Ore minerals are argentite and electrum, together with pyrite, sphalerite, galena, chalcopyrite, minor bornite, covellite, and ruby silver. Wall rock alteration is characterized by narrow (propylitic alteration. Gangue minerals are dominantly massive quartz intergrown with minor to accessory adularia. Epidote, illite, illite/smectite, and, preferentially at deeper levels, Fe-chlorite gangue indicate near-neutral pH hydrothermal fluids at temperatures of >220°C. Kaolinite occurring with the late sulfide-rich veinlet stage indicates pH 315°, whereas strike

  17. Radiological symptoms of the disfunction of artificial heart valves

    Energy Technology Data Exchange (ETDEWEB)

    Erdelyi, M Jr [Orszagos Roentgen es Sugarfizikai Intezet, Budapest (Hungary)

    1981-01-31

    The possible causes of the disfunction of artificial valves are detailed. Routine X-ray examinations of the chest only rarely reveal direct signs of disfunction, but the haemodynamic alterations (dilated heart chambers, or veins) must be considered as important indirect signs. The characteristics and possibly the cause of the valve insufficience can be analyzed on the basis of kino- and spot radiograms. The symptoms observed by these methods are reported in detail.

  18. Case report of a modified Meso-Rex bypass as a treatment technique for late-onset portal vein cavernous transformation with portal hypertension after adult deceased-donor liver transplantation.

    Science.gov (United States)

    Han, Dongdong; Tang, Rui; Wang, Liang; Li, Ang; Huang, Xin; Shen, Shan; Dong, Jiahong

    2017-06-01

    Portal vein thrombosis is a complication after liver transplantation and cavernous transformation of the portal vein (CTPV) is a result of portal vein thrombosis, with symptoms of portal hypertension revealed by an enhanced CT scan. Meso-Rex bypass is an artificial shunt connecting the left portal vein to the superior mesenteric vein and is mainly used for idiopathic cavernomas. This technique is also used for post-transplant portal vein thrombosis in pediatric patients thereby bypassing obstructed sites of the extrahepatic portal vein. Here we report about an adult patient who was treated by connecting the cystic part of the portal vein to the splenic vein instead of the superior mesenteric vein. An adult male patient with post-liver transplantation portal vein cavernous transformation suffered from hypersplenism and elevated hepatic enzymes. The last follow up revealed irregular and obvious hypersplenism, and splenomegaly had occurred, while an enhanced CT scan revealed serious esophagogastric varices and CTPV in addition to occluded right and common PV trunks. The patient was treated by connecting the cystic part of the portal vein to the splenic vein instead of the superior mesenteric vein. After the operation, a satisfactory velocity was confirmed 1 month postoperatively and the shunt still remained patent at the 6-month postoperation follow-up. A Meso-Rex bypass intervention connecting the left portal vein to the splenic vein instead of the superior mesenteric vein after liver transplantation in an adult patient with right and common portal vein occlusions has been successfully performed as an alternative approach.

  19. SOME PARADIGMS OF ARTIFICIAL INTELLIGENCE IN FINANCIAL COMPUTER SYSTEMS

    OpenAIRE

    Jerzy Balicki

    2015-01-01

    The article discusses some paradigms of artificial intelligence in the context of their applications in computer financial systems. The proposed approach has a significant po-tential to increase the competitiveness of enterprises, including financial institutions. However, it requires the effective use of supercomputers, grids and cloud computing. A reference is made to the computing environment for Bitcoin. In addition, we characterized genetic programming and artificial neural networks to p...

  20. Design and performance of heart assist or artificial heart control systems

    Science.gov (United States)

    Webb, J. A., Jr.; Gebben, V. D.

    1978-01-01

    The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.

  1. The Artificial Hamiltonian, First Integrals, and Closed-Form Solutions of Dynamical Systems for Epidemics

    Science.gov (United States)

    Naz, Rehana; Naeem, Imran

    2018-03-01

    The non-standard Hamiltonian system, also referred to as a partial Hamiltonian system in the literature, of the form {\\dot q^i} = {partial H}/{partial {p_i}},\\dot p^i = - {partial H}/{partial {q_i}} + {Γ ^i}(t,{q^i},{p_i}) appears widely in economics, physics, mechanics, and other fields. The non-standard (partial) Hamiltonian systems arise from physical Hamiltonian structures as well as from artificial Hamiltonian structures. We introduce the term `artificial Hamiltonian' for the Hamiltonian of a model having no physical structure. We provide here explicitly the notion of an artificial Hamiltonian for dynamical systems of ordinary differential equations (ODEs). Also, we show that every system of second-order ODEs can be expressed as a non-standard (partial) Hamiltonian system of first-order ODEs by introducing an artificial Hamiltonian. This notion of an artificial Hamiltonian gives a new way to solve dynamical systems of first-order ODEs and systems of second-order ODEs that can be expressed as a non-standard (partial) Hamiltonian system by using the known techniques applicable to the non-standard Hamiltonian systems. We employ the proposed notion to solve dynamical systems of first-order ODEs arising in epidemics.

  2. The economics of vein disease.

    Science.gov (United States)

    Sales, Clifford M; Podnos, Joan; Levison, Jonathan

    2007-09-01

    The management of cosmetic vein problems requires a very different approach than that for the majority of most other vascular disorders that occur in a vascular surgery practice. This article focuses on the business aspects of a cosmetic vein practice, with particular attention to the uniqueness of these issues. Managing patient expectations is critical to the success of a cosmetic vein practice. Maneuvering within the insurance can be difficult and frustrating for both the patient and the practice. Practices should use cost accounting principles to evaluate the success of their vein work. Vein surgery--especially if performed within the office--can undergo an accurate break-even analysis to determine its profitability.

  3. Polymetallic mineralised veins in ferroan/A-type Cretaceous leucogranite, Stewart Island, New Zealand

    International Nuclear Information System (INIS)

    Allibone, A.H.; MacKenzie, D.; Turnbull, R.E.; Tulloch, A.J.; Craw, D.; Palin, M.

    2016-01-01

    The 140±1 Ma hypersolvus, ferroan, weakly peralkaline to weakly peraluminous North Red Head leucogranite in northwest Stewart Island is cut by quartz-pyrite-rich veins that contain a wide variety of Mo, Ag, Te, Bi, Au, Co, Cu, Pb, Zn, REE, Nb, Y, Th, U, Zr, Ti, Be and F-bearing minerals. Patchy hematite-pyrite alteration locally overprints leucogranite in the vicinity of the mineralised veins. Individual veins are up to 5 m thick and 200+ m long. U-Pb dating and trace-element geochemistry indicate a direct link between leucogranite crystallisation and exsolution of the vein-forming hydrothermal fluid. Mineralised veins developed along transpressional faults within the leucogranite soon after emplacement. Incipiently mineralised quartz?±?pyrite veins at Waituna Bay and the northern end of West Ruggedy Beach several kilometres from North Red Head are probably part of the same hydrothermal system as the veins at North Red Head. Metal and alteration assemblages at North Red Head most closely resemble those in rare hydrothermal systems associated with oxidised fluorine-rich A-type granites. (author).

  4. Advanced solutions in power systems HVDC, facts, and artificial intelligence

    CERN Document Server

    Liu, Chen-Ching; Edris, Abdel-Aty

    2016-01-01

    Provides insight on both classical means and new trends in the application of power electronic and artificial intelligence techniques in power system operation and control This book presents advanced solutions for power system controllability improvement, transmission capability enhancement and operation planning. The book is organized into three parts. The first part describes the CSC-HVDC and VSC-HVDC technologies, the second part presents the FACTS devices, and the third part refers to the artificial intelligence techniques. All technologies and tools approached in this book are essential for power system development to comply with the smart grid requirements.

  5. Deep Vein Thrombosis

    African Journals Online (AJOL)

    OWNER

    Deep Vein Thrombosis: Risk Factors and Prevention in Surgical Patients. Deep Vein ... preventable morbidity and mortality in hospitalized surgical patients. ... the elderly.3,4 It is very rare before the age ... depends on the risk level; therefore an .... but also in the post-operative period. ... is continuing uncertainty regarding.

  6. Solving Complex Logistics Problems with Multi-Artificial Intelligent System

    Directory of Open Access Journals (Sweden)

    Y.K. Tse

    2009-10-01

    Full Text Available The economy, which has become more information intensive, more global and more technologically dependent, is undergoing dramatic changes. The role of logistics is also becoming more and more important. In logistics, the objective of service providers is to fulfill all customers? demands while adapting to the dynamic changes of logistics networks so as to achieve a higher degree of customer satisfaction and therefore a higher return on investment. In order to provide high quality service, knowledge and information sharing among departments becomes a must in this fast changing market environment. In particular, artificial intelligence (AI technologies have achieved significant attention for enhancing the agility of supply chain management, as well as logistics operations. In this research, a multi-artificial intelligence system, named Integrated Intelligent Logistics System (IILS is proposed. The objective of IILS is to provide quality logistics solutions to achieve high levels of service performance in the logistics industry. The new feature of this agile intelligence system is characterized by the incorporation of intelligence modules through the capabilities of the case-based reasoning, multi-agent, fuzzy logic and artificial neural networks, achieving the optimization of the performance of organizations.

  7. Underground geologic evaluation of the Grossschloppen vein-uranium deposit, West Germany

    International Nuclear Information System (INIS)

    Moore, S.C.; Erickson, A.J.; Kolb, S.G.; Maclean, C.J.

    1983-01-01

    The Grossschloppen vein-uranium deposit, Bavaria, West Germany, was examined utilizing underground workings during 1980-82 by Esso Er/ZETA/ GMbH, an affiliate of Exxon Minerals Company (EMC). Geologic evaluation entailed dense drilling of a portion of the deposit from workings constructed specifically for the program. Discovered in 1977, the deposit was initially explored by surface diamond drillholes which allowed definition of a 30-60 m wide vein system discontinuously mineralized along a 1000 m strike length and to at least a 450 m depth. The underground program was conceived as a cost effective procedure to answer questions on vein correlation, grade continuity and variability. A 1200 m decline allowed access for detailed sampling of approximately 10% of the known area of mineralization. Fanned drillholes, logged by gamma probe, were spaced to provide intersections of veins at 10 to 20 m intervals. Six cross cuts also penetrate the pitchblende and uranophane mineralization which occurs in 0.1 to 2.5 m thick quartz veins. Detailed cross-sections and level plans were constructed for resource estimates of the intensively studied portion of the vein system. The program resulted in the discovery of local, high grade areas and an average grade in the evaluated area nearly double that expected from surface drilling

  8. CO2-DSA in lower extremity veins: a clinical application

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; Liu Zhensheng; Li Guozhao; Ding Huijuan; Shen Zhiping; He Shicheng; Deng Gang; Fang Wen

    2005-01-01

    Objective: To explore the feasibility and usefulness of carbon dioxide digital subtraction angiography (CO 2 -DSA) in deep veins of lower extremity via the dorsal is pedis vein. Methods: CO 2 -DSA in lower extremity veins was performed in 15 patients (15 limbs affected, male 9, female 6) by injection of CO 2 via the dorsal is pedis vein. Among them, 8 patients were suspected with deep venous thrombosis (DVT), 6 patients with saphena magna dilation, and 1 patient with a follow-up after thrombolysis due to DVT. Results: Excellent image was obtained in 12 cases, which showed branches of the venous system clearly, as well as the details of DVT. Good image was obtained in 2 cases. Technical failure was encountered in one patient due to inaccessible puncture veins. Mild discomfort (transient pain at the percutaneous site) during the procedure was demonstrated in 11 patients. There was no severe side effects or complications in this series. Conclusion: CO 2 -DSA in lower extremity veins is feasible and safe, the preliminary result is satisfactory. (authors)

  9. SOME PARADIGMS OF ARTIFICIAL INTELLIGENCE IN FINANCIAL COMPUTER SYSTEMS

    Directory of Open Access Journals (Sweden)

    Jerzy Balicki

    2015-12-01

    Full Text Available The article discusses some paradigms of artificial intelligence in the context of their applications in computer financial systems. The proposed approach has a significant po-tential to increase the competitiveness of enterprises, including financial institutions. However, it requires the effective use of supercomputers, grids and cloud computing. A reference is made to the computing environment for Bitcoin. In addition, we characterized genetic programming and artificial neural networks to prepare investment strategies on the stock exchange market.

  10. Non invasive cardiac vein mapping: Role of multislice CT coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto, E-mail: robertomalag@yahoo.it [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Pezzato, Andrea; Barbiani, Camilla; Sala, Giuseppe; Zamboni, Giulia A. [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Tavella, Domenico [Cardiology Service, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Mucelli, Roberto Pozzi [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy)

    2012-11-15

    Purpose: Coronary venous anatomy is of primary importance when implanting a cardiac resynchronization therapy device, besides, the coronary sinus can be differently enlarged depending on chronic heart failure. The aim of this study is to evaluate the usefulness of Coronary CTA in describing the coronary venous tree and in particular the coronary sinus and detecting main venous system variants. Materials and methods: 301 consecutive patients (196 Male-Sign , mean age 63.74 years) studied for coronary artery disease with 64 slice Coronary CTA were retrospectively examined. The acquisition protocol was the standard acquisition one used for coronary artery evaluation but the cardiac venous system were visualized. The cardiac venous system was depicted using 3D, MPR, cMPR and MIP post-processing reconstructions on an off-line workstation. For each patient image quality, presence and caliber of the coronary sinus (CS), great cardiac vein (GCV), middle vein (MV), anterior interventricular vein (AIV), lateral cardiac vein (LCV), posterior cardiac vein (PCV), small cardiac vein (SCV) and presence of variant of the normal anatomy were examined and recorded. Results: CS, GCV, MV and AIV were visualized in 100% of the cases. The LCV was visualized in 255/301 (84%) patients, the PCV in 248/301 (83%) patients and the SCV in 69/301 (23%) patients. Mean diameter of the CS was 8.7 mm in 276/301 (91.7%) patients without chronic heart failure and 9.93 mm in 25/301 (8.3%) patients with chronic heart failure. Conclusions: Coronary CTA allows non invasive mapping of the cardiac venous system and may represent a useful presurgical tool for biventricular pacemaker devices implantation.

  11. Using Weightless Neural Networks for Vergence Control in an Artificial Vision System

    Directory of Open Access Journals (Sweden)

    Karin S. Komati

    2003-01-01

    Full Text Available This paper presents a methodology we have developed and used to implement an artificial binocular vision system capable of emulating the vergence of eye movements. This methodology involves using weightless neural networks (WNNs as building blocks of artificial vision systems. Using the proposed methodology, we have designed several architectures of WNN-based artificial vision systems, in which images captured by virtual cameras are used for controlling the position of the ‘foveae’ of these cameras (high-resolution region of the images captured. Our best architecture is able to control the foveae vergence movements with average error of only 3.58 image pixels, which is equivalent to an angular error of approximately 0.629°.

  12. The comparative anatomy of the forelimb veins of primates.

    OpenAIRE

    Thiranagama, R; Chamberlain, A T; Wood, B A

    1989-01-01

    One hundred and thirteen forelimbs taken from 62 individuals belonging to 17 primate genera were dissected to reveal the entire course of the superficial venous system. The course of the deep venous system was also documented in at least one forelimb of each primate genus, and the number and location of perforating veins was recorded in 18 human and 45 non-human primate limbs. In Pan, Gorilla and in about 25% of human specimens the lateral superficial vein was confined to the forearm, while i...

  13. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy – Case report

    Directory of Open Access Journals (Sweden)

    Jianlin Tang

    2014-12-01

    Conclusion: The lessons we learned are (1 Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2 Synthetic graft is an alternative for internal jugular vein graft. (3 Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4 It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.

  14. Vein visualization: patient characteristic factors and efficacy of a new infrared vein finder technology.

    Science.gov (United States)

    Chiao, F B; Resta-Flarer, F; Lesser, J; Ng, J; Ganz, A; Pino-Luey, D; Bennett, H; Perkins, C; Witek, B

    2013-06-01

    We investigated the patient characteristic factors that correlate with identification of i.v. cannulation sites with normal eyesight. We evaluated a new infrared vein finding (VF) technology device in identifying i.v. cannulation sites. Each subject underwent two observations: one using the conventional method (CM) of normal, unassisted eyesight and the other with the infrared VF device, VueTek's Veinsite™ (VF). A power analysis for moderate effect size (β=0.95) required 54 samples for within-subject differences. Patient characteristic profiles were obtained from 384 subjects (768 observations). Our sample population exhibited an overall average of 5.8 [95% confidence interval (CI) 5.4-6.2] veins using CM. As a whole, CM vein visualization were less effective among obese [4.5 (95% CI 3.8-5.3)], African-American [4.6 (95% CI 3.6-5.5 veins)], and Asian [5.1 (95% CI 4.1-6.0)] subjects. Next, the VF technology identified an average of 9.1 (95% CI 8.6-9.5) possible cannulation sites compared with CM [average of 5.8 (95% CI 5.4-6.2)]. Seventy-six obese subjects had an average of 4.5 (95% CI 3.8-5.3) and 8.2 (95% CI 7.4-9.1) veins viewable by CM and VF, respectively. In dark skin subjects, 9.1 (95% CI 8.3-9.9) veins were visible by VF compared with 5.4 (95% CI 4.8-6.0) with CM. African-American or Asian ethnicity, and obesity were associated with decreased vein visibility. The visibility of veins eligible for cannulation increased for all subgroups using a new infrared device.

  15. Palliative treatment of TIPS to portal vein tumor thrombosis complicated with portal vein hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Guo Tiansheng; Liu Lang

    2002-01-01

    Objective: To evaluate the palliative therapeutic effects of transjugular intrahepatic portosystemic shunt (TIPS) in portal vein tumor thrombosis (PVTT) complicated with portal vein hypertension, and to discuss the technical skills. Methods: There were 14 cases of end-stage hepatocellular carcinoma complicated with PVTT and portal vein hypertension, the average age was 53.6 yr. There were 8 cases with complete occlusion of main portal vein, 6 eases with incomplete thrombosis, and 5 cases combined with portal vein cavernous transformation. One case had simple hemorrhage, 3 eases had intractable ascites, and 10 cases had hemorrhage accompanied by intractable ascites. Results: The procedure of TIPS was successful in 10 cases, the successful rate was about 71%. The mean portal vein pressure was reduced from 37.2 mm Hg to 18.2 mm Hg, with an average reduction of 19.0 mm Hg. After the procedure of TIPS, the ascites decreased, hemorrhage stopped and the clinical symptoms disappeared. The average survival period was 132.3 days. The procedure were failing in 4 cases. Conclusion: TIPS was an effective palliative therapeutic methods to control the hemorrhage and ascites aroused by hepatic carcinoma complicated with PVTT

  16. Beta irradiation inhibits neo-intimal formation in vein grafts

    International Nuclear Information System (INIS)

    Lang Xiaoou; Ji Shenquan; Zeng Ke; Li Jun; Liu Bingbing; Ma Wenfeng; Zhang Qiang

    2002-01-01

    Objective: The study was to evaluate the effect of beta irradiation on intimal proliferation response in vein grafts. Methods: An autogenous vein graft model was established in 40 rats by transplanting internal branch of jugular vein to carotid artery by end-to-end anastomosis. The vein was irradiated by 32 P before anastomosis. Four dose schedules were studied: (1) control graft (nonirradiated); (2) irradiated with 8 Gy; (3) 18 Gy; and (4) 36 Gy. The grafted veins were harvested at 2 weeks after the operation. IH (intimal hyperplasia) and SMC (smooth muscle cell) proliferation were histologically and immuno-histochemically observed and analyzed by a computer digitalising system. Results: In 18 Gy and 36 Gy-irradiated grafts compared with the control, there was a significant decrease in the average intimal thickness (P 0.05). Immunohistochemical analysis of PCNA indicated decrease of positive cells in both 18 Gy and 36 Gy groups compared with 8 Gy and the control group (P 0.05) groups, and there was also no significant difference between 8 Gy and the control group (P > 0.05). Conclusion: These preliminary results demonstrate that proper dose of beta irradiation in vein graft inhibits smooth muscle cells proliferation and neo-intimal hyperplasia in rat

  17. A rare case of anastomosis between the external and internal jugular veins.

    Science.gov (United States)

    Karapantzos, Ilias; Zarogoulidis, Paul; Charalampidis, Charalampos; Karapantzou, Chrysanthi; Kioumis, Ioannis; Tsakiridis, Kosmas; Mpakas, Andrew; Sachpekidis, Nikolaos; Organtzis, John; Porpodis, Konstantinos; Zarogoulidis, Konstantinos; Pitsiou, Georgia; Zissimopoulos, Athanasios; Kosmidis, Christoforos; Fouka, Evagelia; Demetriou, Theodoros

    2016-01-01

    Jugular veins bring deoxygenated blood from the head back to the heart. There are two sets of external and internal veins. The external jugular vein receives the greater part of the blood from the cranium and the deep parts of the face. It commences from the substance of the parotid gland and runs down the neck at the posterior border of sternocleidomastoideus and ends in the subclavian vein in front of the scalenus anterior. The external jugular vein is covered by the platysma and its upper half runs parallel with the great auricular nerve. There is also another minor jugular vein, the anterior, draining the submaxillary region. In our patient, we recognized a shunt between the external and internal jugular veins. It appeared in the middle of the veins, between the pair of valves, which are placed ~2.5 cm above the termination of the vessel. The anastomosis was fully functional, and there was no problem in the blood pressure of the patient. Moreover, the shunt was not associated with any systemic disease.

  18. Utilization of artificial intelligence techniques for the Space Station power system

    Science.gov (United States)

    Evatt, Thomas C.; Gholdston, Edward W.

    1988-01-01

    Due to the complexity of the Space Station Electrical Power System (EPS) as currently envisioned, artificial intelligence/expert system techniques are being investigated to automate operations, maintenance, and diagnostic functions. A study was conducted to investigate this technology as it applies to failure detection, isolation, and reconfiguration (FDIR) and health monitoring of power system components and of the total system. Control system utilization of expert systems for load scheduling and shedding operations was also researched. A discussion of the utilization of artificial intelligence/expert systems for Initial Operating Capability (IOC) for the Space Station effort is presented along with future plans at Rocketdyne for the utilization of this technology for enhanced Space Station power capability.

  19. Palm Vein Verification Using Multiple Features and Locality Preserving Projections

    Directory of Open Access Journals (Sweden)

    Ali Mohsin Al-juboori

    2014-01-01

    Full Text Available Biometrics is defined as identifying people by their physiological characteristic, such as iris pattern, fingerprint, and face, or by some aspects of their behavior, such as voice, signature, and gesture. Considerable attention has been drawn on these issues during the last several decades. And many biometric systems for commercial applications have been successfully developed. Recently, the vein pattern biometric becomes increasingly attractive for its uniqueness, stability, and noninvasiveness. A vein pattern is the physical distribution structure of the blood vessels underneath a person’s skin. The palm vein pattern is very ganglion and it shows a huge number of vessels. The attitude of the palm vein vessels stays in the same location for the whole life and its pattern is definitely unique. In our work, the matching filter method is proposed for the palm vein image enhancement. New palm vein features extraction methods, global feature extracted based on wavelet coefficients and locality preserving projections (WLPP, and local feature based on local binary pattern variance and locality preserving projections (LBPV_LPP have been proposed. Finally, the nearest neighbour matching method has been proposed that verified the test palm vein images. The experimental result shows that the EER to the proposed method is 0.1378%.

  20. Quantitative estimation of compliance of human systemic veins by occlusion plethysmography with radionuclide

    International Nuclear Information System (INIS)

    Takatsu, Hisato; Gotoh, Kohshi; Suzuki, Takahiko; Ohsumi, Yukio; Yagi, Yasuo; Tsukamoto, Tatsuo; Terashima, Yasushi; Nagashima, Kenshi; Hirakawa, Senri

    1989-01-01

    Volume-pressure relationship and compliance of human systemic veins were estimated quantitatively and noninvasively using radionuclide. The effect of nitroglycerin (NTG) on these parameters was examined. Plethysmography with radionuclide (RN) was performed using the occlusion method on the forearm in 56 patients with various cardiac diseases after RN angiocardiography with 99m Tc-RBC. The RN counts-venous pressure curve was constructed from (1) the changes in radioactivity from region of interest on the forearm that were considered to reflect the changes in the blood volume of the forearm, and (2) the changes in the pressure of the forearm vein (fv) due to venous occlusion. The specific compliance of the forearm veins (Csp.fv; (1/V)·(ΔV/ΔP)) was obtained graphically from this curve at each patient's venous pressure (Pv). Csp.fv was 0.044±0.012 mmHg -1 in class I (mean±SD; n=13), 0.033±0.007 mmHg -1 in class II (n=30), and 0.019±0.007 mmHg -1 in class III (n=13), of the previous NYHA classification of work tolerance. There were significant differences in Csp.fv among the three classes. The systemic venous blood volume (Vsv) was determined by subtracting the central blood volume, measured by RN-angiocardiography, from total blood volume, measured by the indicator dilution method utilizing 131 I-human serum albumin. Systemic venous compliance (Csv) was calculated from Csv=Csp.fv·Vsv. The Csv was 127.2±24.8 ml·mmHg -1 (mean±SD) in class I, 101.1±24.1 ml·mmHg -1 in class II and 62.2±28.1 ml·mmHg -1 in class III. There were significant differences in Csv among the three classes. The class I Csv value was calculated to be 127.2±24.8 ml·mmHg -1 and the Csv/body weight was calculated to be 2.3±0.7 ml·mmHg -1 ·kg -1 of body weight. The administration of NTG increased Csv significantly in all cases. (J.P.N.)

  1. Near-infrared image formation and processing for the extraction of hand veins

    Science.gov (United States)

    Bouzida, Nabila; Hakim Bendada, Abdel; Maldague, Xavier P.

    2010-10-01

    The main objective of this work is to extract the hand vein network using a non-invasive technique in the near-infrared region (NIR). The visualization of the veins is based on a relevant feature of the blood in relation with certain wavelengths of the electromagnetic spectrum. In the present paper, we first introduce the image formation in the NIR spectral band. Then, the acquisition system will be presented as well as the method used for the image processing in order to extract the vein signature. Extractions of this pattern on the finger, on the wrist and on the dorsal hand are achieved after exposing the hand to an optical stimulation by reflection or transmission of light. We present meaningful results of the extracted vein pattern demonstrating the utility of the method for a clinical application like the diagnosis of vein disease, of primitive varicose vein and also for applications in vein biometrics.

  2. Geology, mineralogy and ore fluid characteristics of the Masjed Daghi gold bearing veins system, NW Iran

    Directory of Open Access Journals (Sweden)

    Susan Ebrahimi

    2017-11-01

    Full Text Available Introduction The Masjed- Daghi gold deposit lies in an area of widespread Cenozoic volcanic and plutonic rocks at the intersection of the Alborz- Azarbaijan and Urumieh- Dokhtar belts. The area was covered by a detailed exploration program, including geological maps at 1:1,000 scales (~8 km², several hundred meters of trenches and systematic sampling for Au, Ag, Pb, Zn, Cu, As, Hg analysis, and 16 diamond drill holes at a total of 1200 meters (Mohammadi et al, 2005. The vein type gold deposit in Masjed- Daghi is closely associated with a porphyry type Cu-Au deposit. Our study focuses on the gold bearing veins system in an attempt to understand the characteristics of ore fluids and mechanisms of ore formation, and to develop exploration criteria for Masjed Daghi and similar occurrences in Alborz and other Cenozoic magmatic assemblages in Iran. Materials and methods Various rock types, alteration assemblages and mineral parageneses were characterized by transmitting and reflected light microscopy, X-ray diffraction (XRD and electron microprobe analysis. Microprobe analyses were performed using a JEOL 8600 Superprobe electron microprobe at Saskatchewan University. Operating conditions were an accelerating voltage of 15 kV and a beam current of 50 nA. Representative samples from drill holes were selected for fluid inclusion studies. Fluid inclusion data were obtained using a fluid Inc. adapted USGS gas flow heating and freezing system at the Department of Geological Science at the University of Saskatchewan, Canada. To investigate the source of ore fluids, representative sulfidic samples from drill holes were selected for sulfur isotope studies. Isotopic analyses were performed using a Thermo Finnigan DeltaPlus at the G.G. Hatch Stable Isotope Laboratories, University of Ottawa. The standard error of analyses is less than ±0.1 per mil. Results Auriferous quartz veins in Masjed- Daghi are associated with porphyry style mineralization. Various

  3. Systems in Science: Modeling Using Three Artificial Intelligence Concepts.

    Science.gov (United States)

    Sunal, Cynthia Szymanski; Karr, Charles L.; Smith, Coralee; Sunal, Dennis W.

    2003-01-01

    Describes an interdisciplinary course focusing on modeling scientific systems. Investigates elementary education majors' applications of three artificial intelligence concepts used in modeling scientific systems before and after the course. Reveals a great increase in understanding of concepts presented but inconsistent application. (Author/KHR)

  4. An introduction to artificial intelligence and its potential use in space systems.

    OpenAIRE

    McDonald, Gary Wayne

    1986-01-01

    Approved for public release; distribution is unlimited This thesis provides an introduction to Artificial Intelligence and Space Systems, with comments regarding their integration. The survey of Artificial Intelligence (AI) is based upon a review of its history, its philosophical development, and subcategories of its current technologies. These subcategories are Expert Systems (ES), Natural Language Processing (NLP), Computer Vision and Pattern Recognition, and Robotic...

  5. Concerns and Discomforts of Pregnancy - Varicose Veins

    Science.gov (United States)

    Concerns and Discomforts of Pregnancy - Varicose Veins Varicose veins are enlarged veins you may see on your ... Healthy Roads Media project www. healthyroadsmedia. org English - Concerns and Discomforts of Pregnancy (Varicose Veins) Last reviewed ...

  6. Corrosion cast study of the canine hepatic veins.

    Science.gov (United States)

    Uršič, M; Vrecl, M; Fazarinc, G

    2014-11-01

    This study presents a detailed description of the distribution, diameters and drainage patterns of hepatic veins on the basis of the corrosion cast analysis in 18 dogs. We classified the hepatic veins in three main groups: the right hepatic veins of the caudate process and right lateral liver lobe, the middle hepatic veins of the right medial and quadrate lobes and the left hepatic veins of both left liver lobes and the papillary process. The corrosion cast study showed that the number of the veins in the Nomina Anatomica Veterinaria and most anatomical textbooks is underestimated. The number of various-sized hepatic veins of the right liver division ranged from 3 to 5 and included 1 to 4 veins from the caudate process and 2 to 4 veins from the right lateral liver lobe. Generally, in all corrosion casts, one middle-sized vein from the right part of the right medial lobe, which emptied separately in the caudal vena cava, was established. The other vein was a large-sized vein from the remainder of the central division, which frequently joined the common left hepatic vein from the left liver lobes. The common left hepatic vein was the largest of all the aforementioned hepatic veins.

  7. Vibration behavior of the artificial barrier system

    Energy Technology Data Exchange (ETDEWEB)

    Mikoshiba, Tadashi; Ogawa, Nobuyuki; Nakamura, Izuru [National Research Inst. for Earth sceince and Disaster Prevention (Japan)

    2000-02-01

    This study aims at production of a mimic specimen of artificial barrier, experimental elucidation of influence of seismic motion due to a vibration experiment on the artificial barrier system, and establishment of an evaluating method on its long-term behavior. The study has been carried out under a cooperative study of the National Research Institute for Earth Science and Disaster Prevention and the Japan Nuclear Cycle Development Institute. In 1998 fiscal year, an artificial barrier specimen initiated by crosscut road was produced, and their random wave and actual seismic wave vibrations were carried out to acquire their fundamental data. As a result of the both vibrations, it was found that in a Case 2 specimen of which buffer material was swelled by poured water, the material was integrated with a mimic over-pack to vibrate under judgement of eigen-frequency, maximum acceleration ratio, and so forth on the test results. And, in a Case 1 specimen, it was thought that the mimic over-pack showed an extreme non-linear performance (soft spring) because of reducing eigen-frequency with increase of its vibration level. (G.K.)

  8. Vibration behavior of the artificial barrier system

    International Nuclear Information System (INIS)

    Mikoshiba, Tadashi; Ogawa, Nobuyuki; Nakamura, Izuru

    2000-01-01

    This study aims at production of a mimic specimen of artificial barrier, experimental elucidation of influence of seismic motion due to a vibration experiment on the artificial barrier system, and establishment of an evaluating method on its long-term behavior. The study has been carried out under a cooperative study of the National Research Institute for Earth Science and Disaster Prevention and the Japan Nuclear Cycle Development Institute. In 1998 fiscal year, an artificial barrier specimen initiated by crosscut road was produced, and their random wave and actual seismic wave vibrations were carried out to acquire their fundamental data. As a result of the both vibrations, it was found that in a Case 2 specimen of which buffer material was swelled by poured water, the material was integrated with a mimic over-pack to vibrate under judgement of eigen-frequency, maximum acceleration ratio, and so forth on the test results. And, in a Case 1 specimen, it was thought that the mimic over-pack showed an extreme non-linear performance (soft spring) because of reducing eigen-frequency with increase of its vibration level. (G.K.)

  9. Artificial intelligence approach to accelerator control systems

    International Nuclear Information System (INIS)

    Schultz, D.E.; Hurd, J.W.; Brown, S.K.

    1987-01-01

    An experiment was recently started at LAMPF to evaluate the power and limitations of using artificial intelligence techniques to solve problems in accelerator control and operation. A knowledge base was developed to describe the characteristics and the relationships of the first 30 devices in the LAMPF H+ beam line. Each device was categorized and pertinent attributes for each category defined. Specific values were assigned in the knowledge base to represent each actual device. Relationships between devices are modeled using the artificial intelligence techniques of rules, active values, and object-oriented methods. This symbolic model, built using the Knowledge Engineering Environment (KEE) system, provides a framework for analyzing faults, tutoring trainee operators, and offering suggestions to assist in beam tuning. Based on information provided by the domain expert responsible for tuning this portion of the beam line, additional rules were written to describe how he tunes, how he analyzes what is actually happening, and how he deals with failures. Initial results have shown that artificial intelligence techniques can be a useful adjunct to traditional methods of numerical simulation. Successful and efficient operation of future accelerators may depend on the proper merging of symbolic reasoning and conventional numerical control algorithms

  10. Nanoporous biomaterials for uremic toxin adsorption in artificial kidney systems: A review.

    Science.gov (United States)

    Cheah, Wee-Keat; Ishikawa, Kunio; Othman, Radzali; Yeoh, Fei-Yee

    2017-07-01

    Hemodialysis, one of the earliest artificial kidney systems, removes uremic toxins via diffusion through a semipermeable porous membrane into the dialysate fluid. Miniaturization of the present hemodialysis system into a portable and wearable device to maintain continuous removal of uremic toxins would require that the amount of dialysate used within a closed-system is greatly reduced. Diffused uremic toxins within a closed-system dialysate need to be removed to maintain the optimum concentration gradient for continuous uremic toxin removal by the dialyzer. In this dialysate regenerative system, adsorption of uremic toxins by nanoporous biomaterials is essential. Throughout the years of artificial kidney development, activated carbon has been identified as a potential adsorbent for uremic toxins. Adsorption of uremic toxins necessitates nanoporous biomaterials, especially activated carbon. Nanoporous biomaterials are also utilized in hemoperfusion for uremic toxin removal. Further miniaturization of artificial kidney system and improvements on uremic toxin adsorption capacity would require high performance nanoporous biomaterials which possess not only higher surface area, controlled pore size, but also designed architecture or structure and surface functional groups. This article reviews on various nanoporous biomaterials used in current artificial kidney systems and several emerging nanoporous biomaterials. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1232-1240, 2017. © 2016 Wiley Periodicals, Inc.

  11. Normal hepatic vein patterns on ultrasound

    International Nuclear Information System (INIS)

    Kim, Hae Jin; Chae, Yoo Soon; Park, Hea Yeoung; Park, Bok Hwan; Kim, Yang Sook

    1987-01-01

    Understanding of the anatomy of the hepatic vein is important in manipulation for transplantation of the liver, hepatectomy and the treatment of hepatic trauma with avulsion of the hepatic vein. Demonstrated of the inferior right hepatic vein (IRHV) is also important; in some cases of hepatocellular carcinoma, thrombus can be seen in the IRHV; in primary Budd-Chiari syndrome, the IRHV is main draining vein; during hepatectomy, the postero-inferior segment of the right lobe and draining IRHV can be preserved. For some 10 months ultrasound examination was done in a total of 124 patients with normal liver function with special emphasis on the hepatic vein, their branches, and the IRHV, and analysed in terms of branching pattern and relative size of the hepatic vein and the detection rate of the IRHV.

  12. Finger Vein Recognition Using Optimal Partitioning Uniform Rotation Invariant LBP Descriptor

    Directory of Open Access Journals (Sweden)

    Bang Chao Liu

    2016-01-01

    Full Text Available As a promising biometric system, finger vein identification has been studied widely and many relevant researches have been proposed. However, it is hard to extract a satisfied finger vein pattern due to the various vein thickness, illumination, low contrast region, and noise existing. And most of the feature extraction algorithms rely on high-quality finger vein database and take a long time for a large dimensional feature vector. In this paper, we proposed two block selection methods which are based on the estimate of the amount of information in each block and the contribution of block location by looking at recognition rate of each block position to reduce feature extraction time and matching time. The specific approach is to find out some local finger vein areas with low-quality and noise, which will be useless for feature description. Local binary pattern (LBP descriptors are proposed to extract the finger vein pattern feature. Two finger vein databases are taken to test our algorithm performance. Experimental results show that proposed block selection algorithms can reduce the feature vector dimensionality in a large extent.

  13. Idiopathic Bilateral External Jugular Vein Thrombosis.

    Science.gov (United States)

    Hindi, Zakaria; Fadhel, Ehab

    2015-08-20

    Vein thrombosis is mainly determined by 3 factors, which constitute a triad called Virchow's triad: hypercoagulability, stasis, and endothelial injury. Venous thrombosis commonly occurs in the lower extremities since most of the blood resides there and flows against gravity. The veins of the lower extremities are dependent on intact valves and fully functional leg muscles. However, in case of valvular incompetency or muscular weakness, thrombosis and blood stasis will occur as a result. In contrast, the veins of the neck, specially the jugulars, have distensible walls which allow flexibility during respiration. In addition, the blood directly flows downward towards the heart. Nevertheless, many case reports mentioned the thrombosis of internal jugular veins and external jugular veins with identified risk factors. Jugular vein thrombosis has previously been associated in the literature with a variety of medical conditions, including malignancy. This report is of a case of idiopathic bilateral external jugular vein thrombosis in a 21 year-old male construction worker of Southeast Asian origin with no previous medical history who presented with bilateral facial puffiness of gradual onset over 1 month. Doppler ultrasound and computed tomography were used in the diagnosis. Further work-up showed no evidence of infection or neoplasia. The patient was eventually discharged on warfarin. The patient was assessed after 6 months and his symptoms had resolved completely. Bilateral idiopathic external jugular veins thrombosis is extremely rare and can be an indicator of early malignancy or hidden infection. While previous reports in the literature have associated jugular vein thrombosis with malignancy, the present case shows that external jugular vein thrombosis can also be found in persons without malignancy.

  14. Bilateral retinal vein occlusion and rubeosis irides: lessons to learn.

    Science.gov (United States)

    Md Noh, Umi Kalthum; Ahem, Amin; Mustapha, Mushawiahti

    2013-01-01

    Uncontrolled hypertension is well- known to give rise to systemic complications involving multiple central organs. Artherosclerosis leads to damage of the retinal vessels wall, contributing to venous stasis, thrombosis and finally, occlusion. Retinal vein occlusions compromise vision through development of ischaemic maculopathy, macular oedema, and rubeotic glaucoma. Laser photocoagulation remains the definitive treatment for ischaemic vein occlusion with secondary neovascularization. Timely treatment with anti- vascular endothelial growth factor prevents development of rubeotic glaucoma. We hereby report an unusual case of bilateral retinal vein occlusion complicated by rubeosis irides, which was successfully managed to improve vision and prevent rubeotic glaucoma.

  15. Blood sampling from adrenal gland vein

    International Nuclear Information System (INIS)

    Sun Yong; Ni Caifang

    2009-01-01

    Adrenal gland vein sampling is an interventional method to get the blood samples from the adrenal gland vein. The blood is obtained via a catheter which is selectively inserted in the adrenal gland vein. This technique is mainly used to be diagnostic for primary hyperaldosteronism. A full knowledge of the anatomy and variations of the adrenal gland vein, serious preoperative preparation and skilled catheterization manipulation are necessary for obtaining sufficient blood sample and for reducing the occurrence of complications. Providing the physicians with definite diagnostic evidence and being technically feasible, adrenal gland vein sampling should become one of the routine examinations for clarifying the cause of primary hyperaldosteronism. (authors)

  16. Artificial activation of toxin-antitoxin systems as an antibacterial strategy.

    Science.gov (United States)

    Williams, Julia J; Hergenrother, Paul J

    2012-06-01

    Toxin-antitoxin (TA) systems are unique modules that effect plasmid stabilization via post-segregational killing of the bacterial host. The genes encoding TA systems also exist on bacterial chromosomes, and it has been speculated that these are involved in a variety of cellular processes. Interest in TA systems has increased dramatically over the past 5 years as the ubiquitous nature of TA genes on bacterial genomes has been revealed. The exploitation of TA systems as an antibacterial strategy via artificial activation of the toxin has been proposed and has considerable potential; however, efforts in this area remain in the early stages and several major questions remain. This review investigates the tractability of targeting TA systems to kill bacteria, including fundamental requirements for success, recent advances, and challenges associated with artificial toxin activation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Isolated inferior mesenteric portal hypertension with giant inferior mesenteric vein and anomalous inferior mesenteric vein insertion

    Directory of Open Access Journals (Sweden)

    G Raghavendra Prasad

    2013-01-01

    Full Text Available Extrahepatic portal hypertension is not an uncommon disease in childhood, but isolated inferior mesenteric portal varices and lower gastrointestinal (GI bleed have not been reported till date. A 4-year-old girl presented with lower GI bleed. Surgical exploration revealed extrahepatic portal vein obstruction with giant inferior mesenteric vein and colonic varices. Inferior mesenteric vein was joining the superior mesenteric vein. The child was treated successfully with inferior mesenteric - inferior vena caval anastomosis. The child was relieved of GI bleed during the follow-up.

  18. Multimodal ultrasonographic assessment of leiomyosarcoma of the femoral vein in a patient misdiagnosed as having deep vein thrombosis

    Science.gov (United States)

    Zhang, Mei; Yan, Feng; Huang, Bin; Wu, Zhoupeng; Wen, Xiaorong

    2017-01-01

    Abstract Rationale: Primary leiomyosarcoma (LMS) of the vein is a rare tumor that arises from the smooth muscle cells of the vessel wall and has an extremely poor prognosis. This tumor can occur in vessels such as the inferior vena cava, great saphenous vein, femoral vein, iliac vein, popliteal vein, and renal vein; the inferior vena cava is the most common site. LMS of the femoral vein can result in edema and pain in the lower extremity; therefore, it is not easy to be differentiated from deep vein thrombosis (DVT). Moreover, virtually no studies have described the ultrasonographic features of LMS of the vein in detail. Patient concerns: We present a case of a 55-year-old woman with LMS of the left femoral vein that was misdiagnosed as having deep vein thrombosis (DVT) on initial ultrasonographic examination. The patient began to experience edema and pain in her left leg seven months previously. She was diagnosed as having DVT on initial ultrasonographic examination, but the DVT treatment that she had received for 7 months failed to improve the status of her left lower limb. Diagnoses: She subsequently underwent re-examination by means of a multimodal ultrasonographic imaging approach (regular B-mode imaging, color Doppler imaging, pulsed-wave Doppler imaging, contrast-enhanced ultrasonography), which confirmed a diagnosis of LMS. Interventions: This patient was treated successfully with surgery. Outcomes: This case demonstrates that use of multiple ultrasonographic imaging techniques can be helpful to diagnose LMS accurately. Detection of vasculature in a dilated vein filled with a heterogeneous hypoechoic substance on ultrasonography is a sign of a tumor. Lessons: The pitfall of misdiagnosing this tumor as DVT is a useful reminder. PMID:29145269

  19. Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

    Science.gov (United States)

    Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile

    2017-12-01

    Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  20. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex.

    Science.gov (United States)

    Xie, Shan Juan; Lu, Yu; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2015-07-14

    Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc.) vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs). In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV) normalization method using guided filter based single scale retinex (GFSSR) is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  1. Hybrid artificial photosynthetic systems comprising semiconductors as light harvesters and biomimetic complexes as molecular cocatalysts.

    Science.gov (United States)

    Wen, Fuyu; Li, Can

    2013-11-19

    Solar fuel production through artificial photosynthesis may be a key to generating abundant and clean energy, thus addressing the high energy needs of the world's expanding population. As the crucial components of photosynthesis, the artificial photosynthetic system should be composed of a light harvester (e.g., semiconductor or molecular dye), a reduction cocatalyst (e.g., hydrogenase mimic, noble metal), and an oxidation cocatalyst (e.g., photosystem II mimic for oxygen evolution from water oxidation). Solar fuel production catalyzed by an artificial photosynthetic system starts from the absorption of sunlight by the light harvester, where charge separation takes place, followed by a charge transfer to the reduction and oxidation cocatalysts, where redox reaction processes occur. One of the most challenging problems is to develop an artificial photosynthetic solar fuel production system that is both highly efficient and stable. The assembly of cocatalysts on the semiconductor (light harvester) not only can facilitate the charge separation, but also can lower the activation energy or overpotential for the reactions. An efficient light harvester loaded with suitable reduction and oxidation cocatalysts is the key for high efficiency of artificial photosynthetic systems. In this Account, we describe our strategy of hybrid photocatalysts using semiconductors as light harvesters with biomimetic complexes as molecular cocatalysts to construct efficient and stable artificial photosynthetic systems. We chose semiconductor nanoparticles as light harvesters because of their broad spectral absorption and relatively robust properties compared with a natural photosynthesis system. Using biomimetic complexes as cocatalysts can significantly facilitate charge separation via fast charge transfer from the semiconductor to the molecular cocatalysts and also catalyze the chemical reactions of solar fuel production. The hybrid photocatalysts supply us with a platform to study the

  2. Artificial Intelligence at Advanced Information and Decision Systems

    OpenAIRE

    McCune, Brian P.

    1981-01-01

    Advanced Information and Decision Systems (AI-DS) is a relatively new, employee-owned company that does basic and applied research, product development, and consulting in the fields of artificial intelligence, computer science, decision analysis, operations research, control theory, estimation theory, and signal processing. AI&DS performs studies, analyses, systems design and evaluation, and software development for a variety of industrial clients and government agencies, including the Depart...

  3. Portal vein thrombosis.

    Science.gov (United States)

    Chawla, Yogesh K; Bodh, Vijay

    2015-03-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion.

  4. The feasible study of vasodilators in portal vein targeting infusion for treating portal hypertension

    International Nuclear Information System (INIS)

    Wu Hanping; Liang Huiming; Zheng Chuansheng; Feng Gansheng

    2002-01-01

    Objective: To find out the ideal portal vein tar getting injection routes for portal hypertension treatment. Methods: 28 cirrhotic rat models with portal hypertension induced by CCl 4 were divided into 4 groups: inferior caval vein injection group, portal vein injection group, hepatic artery injection group, spleen injection group. The changes in portal vein pressure (PVP), inferior caval vein pressure (ICVP), mean artery pressure (MAP) and heart rate (HR) were monitored before and after prazosin injection. Results: After intra-portal, intra-hepatic arterial or spleen injection of prazosin, larger decrease in PVP and lesser effects on MAP than intravenous injection had been induced. The effect on HR showed no difference among these four groups. Conclusions: Hepatic artery and spleen prazosin administration have the same advantages on treatment of portal hypertension as those of intra-portal infusion, that is the greater decrease on portal vein pressure, the lesser effects on systemic hemodynamics. Vasodilation drugs for hepatic artery infusion through percutaneous port catheter system by hepatic artery implantation would be an ideal method for portal hypertension treatment

  5. Generative Artificial Intelligence : Philosophy and Theory of Artificial Intelligence

    NARCIS (Netherlands)

    van der Zant, Tijn; Kouw, Matthijs; Schomaker, Lambertus; Mueller, Vincent C.

    2013-01-01

    The closed systems of contemporary Artificial Intelligence do not seem to lead to intelligent machines in the near future. What is needed are open-ended systems with non-linear properties in order to create interesting properties for the scaffolding of an artificial mind. Using post-structuralistic

  6. The application of an artificial immune system for solving the identification problem

    Directory of Open Access Journals (Sweden)

    Astachova Irina

    2017-01-01

    Full Text Available Ecological prognosis sets the identification task, which is to find the capacity of pollution sources based on the available experimental data. This problem is an inverse problem, for the solution of which the method of symbolic regression is considered. The distributed artificial immune system is used as an algorithm for the problem solving. The artificial immune system (AIS is a model that allows solving various problems of identification, its concept was borrowed from biology. The solution is sought using a distributed version of the artificial immune system, which is implemented through a network. This distributed network can operate in any heterogeneous environment, which is achieved through the use of cross-platform Python programming language. AIS demonstrates the ability to restore the original function in the problem of identification. The obtained solution for the test data is represented by the graph.

  7. Clonal Selection Based Artificial Immune System for Generalized Pattern Recognition

    Science.gov (United States)

    Huntsberger, Terry

    2011-01-01

    The last two decades has seen a rapid increase in the application of AIS (Artificial Immune Systems) modeled after the human immune system to a wide range of areas including network intrusion detection, job shop scheduling, classification, pattern recognition, and robot control. JPL (Jet Propulsion Laboratory) has developed an integrated pattern recognition/classification system called AISLE (Artificial Immune System for Learning and Exploration) based on biologically inspired models of B-cell dynamics in the immune system. When used for unsupervised or supervised classification, the method scales linearly with the number of dimensions, has performance that is relatively independent of the total size of the dataset, and has been shown to perform as well as traditional clustering methods. When used for pattern recognition, the method efficiently isolates the appropriate matches in the data set. The paper presents the underlying structure of AISLE and the results from a number of experimental studies.

  8. International Conference on Artificial Intelligence and Evolutionary Algorithms in Engineering Systems

    CERN Document Server

    Dash, Subhransu; Panigrahi, Bijaya

    2015-01-01

      The book is a collection of high-quality peer-reviewed research papers presented in Proceedings of International Conference on Artificial Intelligence and Evolutionary Algorithms in Engineering Systems (ICAEES 2014) held at Noorul Islam Centre for Higher Education, Kumaracoil, India. These research papers provide the latest developments in the broad area of use of artificial intelligence and evolutionary algorithms in engineering systems. The book discusses wide variety of industrial, engineering and scientific applications of the emerging techniques. It presents invited papers from the inventors/originators of new applications and advanced technologies.

  9. Inferior vena cava filter insertion through the popliteal vein: enabling the percutaneous endovenous intervention of deep vein thrombosis with a single venous access approach in a single session

    Science.gov (United States)

    Kim, Hyoung Ook; Kim, Jae Kyu; Park, Jin Gyoon; Yim, Nam Yeol; Kang, Yang Jun; Jung, Hye Doo

    2016-01-01

    PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention. PMID:27559713

  10. Case report: Varicosity of the communicating vein between the left renal vein and the left ascending lumbar vein mimicking a renal artery aneurysm: Report of an unusual site of varicose veins and a novel hypothesis to explain its association with abdominal pain

    Directory of Open Access Journals (Sweden)

    Sandeep G Jakhere

    2011-01-01

    Full Text Available A communicating vein between the left renal vein and the left ascending lumbar vein has only rarely been reported in the imaging literature. There are very few reports of varicosity of this communicating vein. Nonetheless, awareness about this communicating vein is of utmost importance for surgeons performing aortoiliac surgeries and nephrectomies as it may pose technical difficulties during surgery or cause life-threatening retroperitoneal hemorrhage. Varicosity of this venous channel may be mistaken for paraaortic lymphadenopathy, adrenal pseudo-mass, or renal artery aneurysm. We report a case of a patient with varicosity of this communicating vein, which mimicked a left renal artery aneurysm. A novel hypothesis is also proposed to explain the relationship with abdominal pain.

  11. Knowledge in Artificial Intelligence Systems: Searching the Strategies for Application

    OpenAIRE

    Kornienko, Alla A.; Kornienko, Anatoly V.; Fofanov, Oleg B.; Chubik, Maxim P.

    2015-01-01

    The studies based on auto-epistemic logic are pointed out as an advanced direction for development of artificial intelligence (AI). Artificial intelligence is taken as a system that imitates the solution of complicated problems by human during the course of life. The structure of symbols and operations, by which intellectual solution is performed, as well as searching the strategic reference points for those solutions, which are caused by certain structures of symbols and operations, – are co...

  12. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex

    Directory of Open Access Journals (Sweden)

    Shan Juan Xie

    2015-07-01

    Full Text Available Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc. vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs. In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV normalization method using guided filter based single scale retinex (GFSSR is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  13. Interventional treatment of iliac vein compression syndrome

    International Nuclear Information System (INIS)

    Li Xiaoqiang; Zhou Weiming; Nie Zhonglin; Yu Chaowen

    2002-01-01

    Objective: To explore the clinical significance of interventional treatment of iliac vein compression syndrome (IVCS). Methods: Percutaneous transluminal angioplasty (PTA) was performed in 40 cases. Thirty-three cases underwent endovascular stent implantation and 27 cases underwent second-stage left saphenous vein ligation and stripping and the valves of left femoral veins narrowing. Thirty-one cases were followed-up postoperatively and the duration was 6-66 months (mean 28 months). Results: The dilation of iliac veins was successful in 36 cases and there were god efficacy in all patients when they discharged from hospital. Followed-up during post-operation, all the limbs ulcers were cured and varicose veins disappeared. The skin pigmentation disappeared in 17 of 19 cases and markedly relieved in 2 cases. Left lower limb swelling disappeared in 15 of 17 cases and relieved in 2 cases. Conclusion: There is good efficacy in the interventional treatment of left iliac vein lesions, but second-stage procedures should be performed in secondary lesions of saphenous veins and valves of femoral veins

  14. Symptomatic paroxysmal atrial fibrillation in a patient with unilateral pulmonary vein atresia

    Directory of Open Access Journals (Sweden)

    Sharmila Sehli

    2015-01-01

    Full Text Available A 52-year-old man with symptomatic paroxysmal atrial fibrillation was offered an atrial fibrillation (AF ablation procedure. His echocardiogram indicated that he had no structural heart disease. A cardiac computed tomographic (CT scan showed enlargement of the right pulmonary veins, absence of the left pulmonary veins, a prominent left atrial appendage, and a hypoplastic left lung. Cardiac CT with an electroanatomic mapping system confirmed a prominent left atrial appendage and the absence of the left pulmonary veins. Due to the limited number of patients with this condition, information about ablation remains very limited, and his ablation was deferred. Unilateral pulmonary vein atresia is a rare condition in adults which results from failure of incorporation of the common pulmonary vein into the left atrium. This case demonstrates the clinical importance of preprocedural imaging prior to AF ablation.

  15. Finger-vein and fingerprint recognition based on a feature-level fusion method

    Science.gov (United States)

    Yang, Jinfeng; Hong, Bofeng

    2013-07-01

    Multimodal biometrics based on the finger identification is a hot topic in recent years. In this paper, a novel fingerprint-vein based biometric method is proposed to improve the reliability and accuracy of the finger recognition system. First, the second order steerable filters are used here to enhance and extract the minutiae features of the fingerprint (FP) and finger-vein (FV). Second, the texture features of fingerprint and finger-vein are extracted by a bank of Gabor filter. Third, a new triangle-region fusion method is proposed to integrate all the fingerprint and finger-vein features in feature-level. Thus, the fusion features contain both the finger texture-information and the minutiae triangular geometry structure. Finally, experimental results performed on the self-constructed finger-vein and fingerprint databases are shown that the proposed method is reliable and precise in personal identification.

  16. Metabolic effects of portal vein sensing.

    Science.gov (United States)

    Mithieux, G

    2014-09-01

    The extrinsic gastrointestinal nerves are crucial in the sensing of nutrients and hormones and its translation in terms of control of food intake. Major macronutrients like glucose and protein are sensed by the extrinsic nerves located in the portal vein walls, which signal to the brain and account for the satiety phenomenon they promote. Glucose is sensed in the portal vein by neurons expressing the glucose receptor SGLT3, which activate the main regions of the brain involved in the control of food intake. Proteins indirectly act on food intake by inducing intestinal gluconeogenesis and its sensing by the portal glucose sensor. The mechanism involves a prior antagonism by peptides of the μ-opioid receptors present in the portal vein nervous system and a reflex arc with the brain inducing intestinal gluconeogenesis. In a comparable manner, short-chain fatty acids produced from soluble fibre act via intestinal gluconeogenesis to exert anti-obesity and anti-diabetic effects. In the case of propionate, the mechanism involves a prior activation of the free fatty acid receptor FFAR3 present in the portal nerves and a reflex arc initiating intestinal gluconeogenesis. © 2014 John Wiley & Sons Ltd.

  17. Effects of artificial gravity on the cardiovascular system: Computational approach

    Science.gov (United States)

    Diaz Artiles, Ana; Heldt, Thomas; Young, Laurence R.

    2016-09-01

    Artificial gravity has been suggested as a multisystem countermeasure against the negative effects of weightlessness. However, many questions regarding the appropriate configuration are still unanswered, including optimal g-level, angular velocity, gravity gradient, and exercise protocol. Mathematical models can provide unique insight into these questions, particularly when experimental data is very expensive or difficult to obtain. In this research effort, a cardiovascular lumped-parameter model is developed to simulate the short-term transient hemodynamic response to artificial gravity exposure combined with ergometer exercise, using a bicycle mounted on a short-radius centrifuge. The model is thoroughly described and preliminary simulations are conducted to show the model capabilities and potential applications. The model consists of 21 compartments (including systemic circulation, pulmonary circulation, and a cardiac model), and it also includes the rapid cardiovascular control systems (arterial baroreflex and cardiopulmonary reflex). In addition, the pressure gradient resulting from short-radius centrifugation is captured in the model using hydrostatic pressure sources located at each compartment. The model also includes the cardiovascular effects resulting from exercise such as the muscle pump effect. An initial set of artificial gravity simulations were implemented using the Massachusetts Institute of Technology (MIT) Compact-Radius Centrifuge (CRC) configuration. Three centripetal acceleration (artificial gravity) levels were chosen: 1 g, 1.2 g, and 1.4 g, referenced to the subject's feet. Each simulation lasted 15.5 minutes and included a baseline period, the spin-up process, the ergometer exercise period (5 minutes of ergometer exercise at 30 W with a simulated pedal cadence of 60 RPM), and the spin-down process. Results showed that the cardiovascular model is able to predict the cardiovascular dynamics during gravity changes, as well as the expected

  18. Genesis of the Assif El Mal Zn-Pb (Cu, Ag) vein deposit. An extension-related Mesozoic vein system in the High Atlas of Morocco. Structural, mineralogical, and geochemical evidence

    Science.gov (United States)

    Bouabdellah, M.; Beaudoin, G.; Leach, D.L.; Grandia, F.; Cardellach, E.

    2009-01-01

    The Assif El Mal Zn-Pb (Cu-Ag) vein system, located in the northern flank of the High Atlas of Marrakech (Morocco), is hosted in a Cambro-Ordovician volcaniclastic and metasedimentary sequence composed of graywacke, siltstone, pelite, and shale interlayered with minor tuff and mudstone. Intrusion of synorogenic to postorogenic Late Hercynian peraluminous granitoids has contact metamorphosed the host rocks giving rise to a metamorphic assemblage of quartz, plagioclase, biotite, muscovite, chlorite, amphibole, chloritoid, and garnet. The Assif El Mal Zn-Pb (Cu-Ag) mineralization forms subvertical veins with ribbon, fault breccia, cockade, comb, and crack and seal textures. Two-phase liquid-vapor fluid inclusions that were trapped during several stages occur in quartz and sphalerite. Primary inclusion fluids exhibit Th mean values ranging from 104??C to 198??C. Final ice-melting temperatures range from -8.1??C to -12.8??C, corresponding to salinities of ???15 wt.% NaCl equiv. Halogen data suggest that the salinity of the ore fluids was largely due to evaporation of seawater. Late secondary fluid inclusions have either Ca-rich, saline (26 wt.% NaCl equiv.), or very dilute (3.5 wt.% NaCl equiv.) compositions and homogenization temperatures ranging from 75??C to 150??C. The ??18O and ??D fluid values suggest an isotopically heterogeneous fluid source involving mixing between connate seawater and black-shale-derived organic waters. Low ??13CVPDB values ranging from -7.5??? to -7.7??? indicate a homogeneous carbon source, possibly organic matter disseminated in black shale hosting the Zn-Pb (Cu-Ag) veins. The calculated ??34SH2S values for reduced sulfur (22.5??? to 24.3???) are most likely from reduction of SO42- in trapped seawater sulfate or evaporite in the host rocks. Reduction of sulfate probably occurred through thermochemical sulfate reduction in which organic matter was oxidized to produce CO2 which ultimately led to precipitation of saddle dolomite with

  19. Model-based restoration using light vein for range-gated imaging systems.

    Science.gov (United States)

    Wang, Canjin; Sun, Tao; Wang, Tingfeng; Wang, Rui; Guo, Jin; Tian, Yuzhen

    2016-09-10

    The images captured by an airborne range-gated imaging system are degraded by many factors, such as light scattering, noise, defocus of the optical system, atmospheric disturbances, platform vibrations, and so on. The characteristics of low illumination, few details, and high noise make the state-of-the-art restoration method fail. In this paper, we present a restoration method especially for range-gated imaging systems. The degradation process is divided into two parts: the static part and the dynamic part. For the static part, we establish the physical model of the imaging system according to the laser transmission theory, and estimate the static point spread function (PSF). For the dynamic part, a so-called light vein feature extraction method is presented to estimate the fuzzy parameter of the atmospheric disturbance and platform movement, which make contributions to the dynamic PSF. Finally, combined with the static and dynamic PSF, an iterative updating framework is used to restore the image. Compared with the state-of-the-art methods, the proposed method can effectively suppress ringing artifacts and achieve better performance in a range-gated imaging system.

  20. The angiographic demonstration of hepatic vein obstruction

    International Nuclear Information System (INIS)

    Zu Maoheng; Xu Hao; Li Guojun; Gu Yuming; Wei Ning; Wang Cheng; Xu Wei

    2004-01-01

    Objective: To evaluate the angiographic feature of hepatic vein obstruction. Methods Forty-five patients (male 23, female 22, age 9-54 years) suffered from hepatic vein obstruction. The inferior vena cavography and the hepatic venography were performed in all cases. Results: IVC was free in 37 patients with hepatic vein obstruction, both IVC and HV were obstructed in 8 patients. The local or long stenosis of IVC was found in 31 inferior vena cavography. The diameter of IVC was normal in 12 patients. The sign of membranous dome was found in hepatic vein orifice in 5 cases and in accessory hepatic vein orifice in 4 cases. Intrahepatic venous collaterals were found in 45 cases. Conclusion: Hepatic vein obstruction can be reproached primarily in inferior vena cavography, the membranous dome is a direct sign of membranous obstruction of HV and AHV in inferior vena cavography. The selected hepatic venography can provide reliable evidence to diagnose hepatic vein obstruction

  1. Mineral vein dynamics modeling (FRACS). Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Urai, J.; Virgo, S.; Arndt, M. [RWTH Aachen (Germany). Geologie-Endogene Dynamik] [and others

    2013-07-15

    The Mineral Vein Dynamics Modeling group ''FRACS'' is a team of 7 research groups from the Universities of Mainz, Aachen, Tuebingen, Karlsruhe, Bayreuth, ETH Zuerich and Glasgow working on an understanding of the dynamic development of fracturing, fluid flow and fracture sealing. World-class field laboratories, especially carbonate sequences from the Oman Mountains are studied and classified. State of the art numerical programs are written, expanded and used to simulate the dynamic interaction of fracturing, flow and resealing and the results are compared with the natural examples. Newest analytical technologies including laser scanning, high resolution X-ray microtomography, fluid inclusion and isotope analysis are performed to understand and compare the results of simulations with natural examples. A new statistical program was developed to classify the natural fracture and vein systems and compare them with dynamic numerical simulations and analytical models. The results of the first project phase are extremely promising. Most of the numerical models have been developed up to the stage where they can be used to simulate the natural examples. The models allow a definition of the first proxies for high fluid pressure and tectonic stresses. It was found out that the Oman Mountains are a complex and very dynamic system that constantly fractures and reseals from the scale of small veins up to the scale of large normal and strike slip faults. The numerical simulations also indicate that the permeability of such systems is not a constant but that the system adjusts to the driving force, for ex-ample high fluid pressure. When the system reseals fast a fluctuating behavior can be observed in the models where the system constantly fractures and reseals, which is in accordance with the observation of the natural laboratory.

  2. Artificial ferroic systems: novel functionality from structure, interactions and dynamics

    International Nuclear Information System (INIS)

    Heyderman, L J; Stamps, R L

    2013-01-01

    Lithographic processing and film growth technologies are continuing to advance, so that it is now possible to create patterned ferroic materials consisting of arrays of sub-1 μm elements with high definition. Some of the most fascinating behaviour of these arrays can be realised by exploiting interactions between the individual elements to create new functionality. The properties of these artificial ferroic systems differ strikingly from those of their constituent components, with novel emergent behaviour arising from the collective dynamics of the interacting elements, which are arranged in specific designs and can be activated by applying magnetic or electric fields. We first focus on artificial spin systems consisting of arrays of dipolar-coupled nanomagnets and, in particular, review the field of artificial spin ice, which demonstrates a wide range of fascinating phenomena arising from the frustration inherent in particular arrangements of nanomagnets, including emergent magnetic monopoles, domains of ordered macrospins, and novel avalanche behaviour. We outline how demagnetisation protocols have been employed as an effective thermal anneal in an attempt to reach the ground state, comment on phenomena that arise in thermally activated systems and discuss strategies for selectively generating specific configurations using applied magnetic fields. We then move on from slow field and temperature driven dynamics to high frequency phenomena, discussing spinwave excitations in the context of magnonic crystals constructed from arrays of patterned magnetic elements. At high frequencies, these arrays are studied in terms of potential applications including magnetic logic, linear and non-linear microwave optics, and fast, efficient switching, and we consider the possibility to create tunable magnonic crystals with artificial spin ice. Finally, we discuss how functional ferroic composites can be incorporated to realise magnetoelectric effects. Specifically, we discuss

  3. Artificial ferroic systems: novel functionality from structure, interactions and dynamics.

    Science.gov (United States)

    Heyderman, L J; Stamps, R L

    2013-09-11

    Lithographic processing and film growth technologies are continuing to advance, so that it is now possible to create patterned ferroic materials consisting of arrays of sub-1 μm elements with high definition. Some of the most fascinating behaviour of these arrays can be realised by exploiting interactions between the individual elements to create new functionality. The properties of these artificial ferroic systems differ strikingly from those of their constituent components, with novel emergent behaviour arising from the collective dynamics of the interacting elements, which are arranged in specific designs and can be activated by applying magnetic or electric fields. We first focus on artificial spin systems consisting of arrays of dipolar-coupled nanomagnets and, in particular, review the field of artificial spin ice, which demonstrates a wide range of fascinating phenomena arising from the frustration inherent in particular arrangements of nanomagnets, including emergent magnetic monopoles, domains of ordered macrospins, and novel avalanche behaviour. We outline how demagnetisation protocols have been employed as an effective thermal anneal in an attempt to reach the ground state, comment on phenomena that arise in thermally activated systems and discuss strategies for selectively generating specific configurations using applied magnetic fields. We then move on from slow field and temperature driven dynamics to high frequency phenomena, discussing spinwave excitations in the context of magnonic crystals constructed from arrays of patterned magnetic elements. At high frequencies, these arrays are studied in terms of potential applications including magnetic logic, linear and non-linear microwave optics, and fast, efficient switching, and we consider the possibility to create tunable magnonic crystals with artificial spin ice. Finally, we discuss how functional ferroic composites can be incorporated to realise magnetoelectric effects. Specifically, we discuss

  4. Validation of artificial skin equivalents as in vitro testing systems

    Science.gov (United States)

    Schmitt, Robert; Marx, Ulrich; Walles, Heike; Schober, Lena

    2011-03-01

    With the increasing complexity of the chemical composition of pharmaceuticals, cosmetics and everyday substances, the awareness of potential health issues and long term damages for humanoid organs is shifting into focus. Artificial in vitro testing systems play an important role in providing reliable test conditions and replacing precarious animal testing. Especially artificial skin equivalents ASEs are used for a broad spectrum of studies like penetration, irritation and corrosion of substances. One major challenge in tissue engineering is the qualification of each individual ASE as in vitro testing system. Due to biological fluctuations, the stratum corneum hornified layer of some ASEs may not fully develop or other defects might occur. For monitoring these effects we developed an fully automated Optical Coherence Tomography device. Here, we present different methods to characterize and evaluate the quality of the ASEs based on image and data processing of OCT B-scans. By analysing the surface structure, defects, like cuts or tears, are detectable. A further indicator for the quality of the ASE is the morphology of the tissue. This allows to determine if the skin model has reached the final growth state. We found, that OCT is a well suited technology for automatically characterizing artificial skin equivalents and validating the application as testing system.

  5. Deep vein thrombosis of the leg

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Hee; Rhee, Kwang Woo; Jeon, Suk Chul; Joo, Kyung Bin; Lee, Seung Ro; Seo, Heung Suk; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1987-04-15

    Ascending contrast venography is the definitive standard method for the diagnosis of deep vein thrombosis (DVT) of the lower extremities. Authors analysed 22 cases of DVT clinically and radiographically. 1.The patients ranged in age from 15 to 70 yrs and the most prevalent age group was 7th decade (31%). There was an equal distribution of males and females. 2.In 11 cases of 22 cases, variable etiologic factors were recognized, such as abdominal surgery, chronic bedridden state, local trauma on the leg, pregnancy, postpartum, Behcet's syndrome, iliac artery aneurysm, and chronic medication of estrogen. 3.Nineteen cases out of 22 cases showed primary venographic signs of DVT, such as well-defined filling defect in opacified veins and narrowed, irregularly filled venous lumen. In only 3 cases, the diagnosis of DVT was base upon the segmental nonvisualization of deep veins with good opacification of proximal and distal veins and presence of collaterals. 4.Extent of thrombosis: 3 cases were confined to calf vein, 4 cases extended to femoral vein, and 15 cases had involvement above iliac vein. 5.In 17 cases involving relatively long segment of deep veins, propagation pattern of thrombus was evaluated by its radiologic morphology according to the age of thrombus: 9 cases suggested central or antegrade propagation pattern and 8 cases, peripheral or retrograde pattern. 6.None of 22 cases showed clinical evidence of pulmonary embolism. The cause of the rarity of pulmonary embolism in Korean in presumed to be related to the difference in major involving site and propagation pattern of DVT in the leg.

  6. Deep vein thrombosis of the leg

    International Nuclear Information System (INIS)

    Lee, Eun Hee; Rhee, Kwang Woo; Jeon, Suk Chul; Joo, Kyung Bin; Lee, Seung Ro; Seo, Heung Suk; Hahm, Chang Kok

    1987-01-01

    Ascending contrast venography is the definitive standard method for the diagnosis of deep vein thrombosis (DVT) of the lower extremities. Authors analysed 22 cases of DVT clinically and radiographically. 1.The patients ranged in age from 15 to 70 yrs and the most prevalent age group was 7th decade (31%). There was an equal distribution of males and females. 2.In 11 cases of 22 cases, variable etiologic factors were recognized, such as abdominal surgery, chronic bedridden state, local trauma on the leg, pregnancy, postpartum, Behcet's syndrome, iliac artery aneurysm, and chronic medication of estrogen. 3.Nineteen cases out of 22 cases showed primary venographic signs of DVT, such as well-defined filling defect in opacified veins and narrowed, irregularly filled venous lumen. In only 3 cases, the diagnosis of DVT was base upon the segmental nonvisualization of deep veins with good opacification of proximal and distal veins and presence of collaterals. 4.Extent of thrombosis: 3 cases were confined to calf vein, 4 cases extended to femoral vein, and 15 cases had involvement above iliac vein. 5.In 17 cases involving relatively long segment of deep veins, propagation pattern of thrombus was evaluated by its radiologic morphology according to the age of thrombus: 9 cases suggested central or antegrade propagation pattern and 8 cases, peripheral or retrograde pattern. 6.None of 22 cases showed clinical evidence of pulmonary embolism. The cause of the rarity of pulmonary embolism in Korean in presumed to be related to the difference in major involving site and propagation pattern of DVT in the leg

  7. Bilateral meandering pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Thupili, Chakradhar R.; Udayasankar, Unni [Pediatric Imaging, Imaging Institute Cleveland Clinic, Cleveland, OH (United States); Renapurkar, Rahul [Imaging Institute Cleveland Clinic, Thoracic Imaging, L10, Cleveland, OH (United States)

    2015-06-15

    Meandering pulmonary veins is a rare clinical entity that can be mistaken for more complex congenital syndromes such as hypogenetic lung syndrome. We report imaging findings in a rare incidentally detected case of bilateral meandering pulmonary veins. We briefly discuss the role of imaging in diagnosing this condition, with particular emphasis on contrast-enhanced CT. (orig.)

  8. Optimal approximation of linear systems by artificial immune response

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper puts forward a novel artificial immune response algorithm for optimal approximation of linear systems. A quaternion model of artificial immune response is proposed for engineering computing. The model abstracts four elements, namely, antigen, antibody, reaction rules among antibodies, and driving algorithm describing how the rules are applied to antibodies, to simulate the process of immune response. Some reaction rules including clonal selection rules, immunological memory rules and immune regulation rules are introduced. Using the theorem of Markov chain, it is proofed that the new model is convergent. The experimental study on the optimal approximation of a stable linear system and an unstable one show that the approximate models searched by the new model have better performance indices than those obtained by some existing algorithms including the differential evolution algorithm and the multi-agent genetic algorithm.

  9. The veining phenomenon in unalloyed plutonium

    International Nuclear Information System (INIS)

    White, J.S.

    1976-01-01

    An investigation has been made of the veining phenomenon in unalloyed plutonium. The surface markings, or veins, which are sometimes seen on α-phase plutonium samples, arise as a result of the β→α transformation. As far as is known, this veining is unrivalled in its scale and form as compared with the solid state surface transformation effects shown by any other metal. The phenomenon has been explained by the application of the Le Chatelier principle to the phase change. In this instance, the large (10%) volume contraction associated with the β→α reaction and the anisotropy of the nonoclinic α-phase structure, account for the fact that the veins are so prominent in plutonium. On the basis of the proposed model, the veins can only form at temperatures where the transformation mechanism is non-martensitic. (Auth.)

  10. Unusual termination of the right testicular vein | Woldeyes | Anatomy ...

    African Journals Online (AJOL)

    The testicular veins are formed by the veins emerging from the testis and epididymis forming the pampiniform venous plexus. The right testicular vein drains into inferior vena cava and the left testicular vein to the left renal vein. Testicular veins display a great variability with regard to their number, course and sites of ...

  11. An Artificial Intelligence-Based Distance Education System: Artimat

    Science.gov (United States)

    Nabiyev, Vasif; Karal, Hasan; Arslan, Selahattin; Erumit, Ali Kursat; Cebi, Ayca

    2013-01-01

    The purpose of this study is to evaluate the artificial intelligence-based distance education system called ARTIMAT, which has been prepared in order to improve mathematical problem solving skills of the students, in terms of conceptual proficiency and ease of use with the opinions of teachers and students. The implementation has been performed…

  12. An artificial intelligence approach to accelerator control systems

    International Nuclear Information System (INIS)

    Schultz, D.E.; Hurd, J.W.; Brown, S.K.

    1987-01-01

    An experiment was recently started at LAMPF to evaluate the power and limitations of using artificial intelligence techniques to solve problems in accelerator control and operation. A knowledge base was developed to describe the characteristics and the relationships of the first 30 devices in the LAMPF H+ beam line. Each device was categorized and pertinent attributes for each category defined. Specific values were assigned in the knowledge base to represent each actual device. Relationships between devices are modeled using the artificial intelligence techniques of rules, active values, and object-oriented methods. This symbolic model, built using the Knowledge Engineering Environment (KEE) system, provides a framework for analyzing faults, tutoring trainee operators, and offering suggestions to assist in beam tuning. Based on information provided by the domain expert responsible for tuning this portion of the beam line, additional rules were written to describe how he tunes, how he analyzes what is actually happening, and how he deals with failures. Initial results have shown that artificial intelligence techniques can be a useful adjunct to traditional methods of numerical simulation. Successful and efficient operation of future accelerators may depend on the proper merging of symbolic reasoning and conventional numerical control algorithms

  13. Investigation of adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents in the iliac vein: insights into developing a better iliac vein stent.

    Science.gov (United States)

    Shida, Takuya; Umezu, Mitsuo; Iwasaki, Kiyotaka

    2018-06-01

    We analyzed the adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents for the treatment of iliac venous thromboembolism and investigated their relationships with the anatomical features of the iliac vein, to gain insights into the development of a better iliac vein stent. Reports of adverse events following the use of stents in the iliac vein were retrieved from the Manufacturer and User Facility Device Experience (MAUDE) database that contain suspected device-associated complications reported to the Food and Drug Administration. Data from 2006 to 2016 were investigated. The literature analysis was also conducted using PubMed, Cochrane Library, EMBASE, and Web of Science focusing on English articles published up to 4 October 2016. The analysis of 88 adverse events from the MAUDE database and 182 articles from the literature revealed that a higher number of adverse events had been reported following the use of arterial stents in the iliac vein compared to CE-marked iliac vein stents. While stent migration and shortening were reported only for the arterial stents, stent fracture and compression occurred regardless of the stent type, even though a vein does not pulsate. A study of the anatomical features of the iliac vein implies that bending, compression, and kink loads are applied to the iliac vein stents in vivo. For designing, developing, and pre-clinical testing of stents intended for use in the iliac vein, the above mechanical load environments induced by the anatomical features should be considered.

  14. Geomorphology and the uranium vein deposits of the Beira region of Portugal

    International Nuclear Information System (INIS)

    Cameron, J.

    1982-01-01

    Geomorphology, river drainage patterns and land form may be related to and indicative of, the presence of metalliferous vein structures, particularly if these are composed of either harder or softer gangue material than the enclosing host rock, and where the structures are relatively recent or uncomplicated by later tectonic movements. The Beira region of Portugal is an excellent example of the relationship between uranium-bearing vein and fault structures and the local geomorphology. The Serra da Estrela mountain range dominates the region and is a horst block whose long axis trends N48 0 E and is bounded by well-defined fracture systems N60 0 E on the north-west side and N35 0 E on the south-east side. The uranium veins, the main river courses and the diabase dyke structures to the north-west and south-east of the mountains are parallel to these two bounding fault systems. The close relationship between the uranium vein structures and the geomorphology, particularly the river courses, must indicate that the veins are young in age and closely related to, but immediately following, the uplift of the Serra da Estrela mountains. The uplift of the Serra da Estrela mountains is caused by the effects of the Alpine movements on the Iberian Peninsula and dated at a probable mid- to late Oligocene age. The uranium vein structures must therefore be close to and immediately following that age. (author)

  15. Development of the pulmonary vein and the systemic venous sinus: an interactive 3D overview.

    Directory of Open Access Journals (Sweden)

    Gert van den Berg

    Full Text Available Knowledge of the normal formation of the heart is crucial for the understanding of cardiac pathologies and congenital malformations. The understanding of early cardiac development, however, is complicated because it is inseparably associated with other developmental processes such as embryonic folding, formation of the coelomic cavity, and vascular development. Because of this, it is necessary to integrate morphological and experimental analyses. Morphological insights, however, are limited by the difficulty in communication of complex 3D-processes. Most controversies, in consequence, result from differences in interpretation, rather than observation. An example of such a continuing debate is the development of the pulmonary vein and the systemic venous sinus, or "sinus venosus". To facilitate understanding, we present a 3D study of the developing venous pole in the chicken embryo, showing our results in a novel interactive fashion, which permits the reader to form an independent opinion. We clarify how the pulmonary vein separates from a greater vascular plexus within the splanchnic mesoderm. The systemic venous sinus, in contrast, develops at the junction between the splanchnic and somatic mesoderm. We discuss our model with respect to normal formation of the heart, congenital cardiac malformations, and the phylogeny of the venous tributaries.

  16. Preoperative mapping of the saphenous vein

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Sillesen, H; Nielsen, Tina G

    1995-01-01

    A consecutive series of 92 patients had their greater saphenous vein assessed with duplex ultrasound scanning prior to planned infrainguinal bypass procedures. A naturally occurring optimal vein diameter was discovered. It was significantly correlated with higher postoperative ankle-brachial pres......-brachial pressure index (ABI) and lesser early postoperative thrombosis. A significant linear regression was found between the pre and postoperative vein diameter....

  17. Testbeam results of the first real-time embedded tracking system with artificial retina

    Energy Technology Data Exchange (ETDEWEB)

    Neri, N., E-mail: nicola.neri@mi.infn.it; Abba, A.; Caponio, F.; Citterio, M.; Coelli, S.; Fu, J.; Merli, A.; Monti, M.; Petruzzo, M.

    2017-02-11

    We present the testbeam results of the first real-time embedded tracking system based on artificial retina algorithm. The tracking system prototype is capable of fast track reconstruction with a latency of the response below 1 μs and track parameter resolutions that are comparable with the offline results. The artificial retina algorithm was implemented in hardware in a custom data acquisition board based on commercial FPGA. The system was tested successfully using a 180 GeV/c proton beam at the CERN SPS with a maximum track rate of about 280 kHz. Online track parameters were found in good agreement with offline results and with the simulated response. - Highlights: • First real-time tracking system based on artificial retina algorithm tested on beam. • Fast track reconstruction within one microsecond latency and offline like quality. • Fast tracking algorithm implemented in commercial FPGAs.

  18. Congenital vascular malformations: the persistence of marginal and embryonal veins.

    Science.gov (United States)

    Weber, J; Daffinger, N

    2006-05-01

    In about 18% of cases with conginental vascular malformations we find a perspective of an atypical truncular vein, located along the outside of the leg, frequently extended from the dorsal foot up to the bottom. In presence of a normally developed system of the deep collecting veins of the lower limb and within the pelvic outflow we are talking about a persisting marginal vein (MV). Hypoplasia or even aplasia of the main deep veins in contrary defines the persisting embryonal vein (EV). Already in childhood these truncular dysplastic veins tend to develop varicose enlargement, causing severe reflux of a huge volume of blood--even more when being associated with av-fistulas (46%). In consequence a rapidly growing chronic venous insufficiency will guide to additional injuries. We have analysed 97 patients showing a persisting MV (n: 92 ) within a total of 102 legs. A persistent embryonal vein (EV) was seen 10 times within this clientel. The persisting truncular veins, associated with phlebectasias and typical clinical symptoms have been examined in a diagnostic "step-by-step" procedure, mainly phlebographically (ascending leg phlebography and varicography), including direct venous blood pressure measurements (phlebodynamometry) and--if needed--by arteriography, showing av-shunting fistulae in 46% of cases. CT and MRI were consulted for the exact therapy planing (frequently initially offered as a non-invasive, however, inadequate key of diagnostic). Actually now these techniques cannot replace pre-operatively the angiographic imaging techniques. The analysis of clinical, morphologic and functional signs, guiding to a specific therapy-relevant classification of MV's and EV's will be presented. And a specific strategy of surgical repair, interventional treatment of av-fistulas and conservative compressive follow-up treatment attempting palliative recompensation of the diseased venous outflow will be discussed also.

  19. The CT appearance of the superior intercostal veins

    International Nuclear Information System (INIS)

    Lund, G.

    1982-01-01

    The CT appearance of the superior intercostal veins is described. The veins are more frequently seen on the right side. The right superior intercostal vein should not be misinterpreted as a paraspinal mass when it is large or bulges into the contour of the right lung. A case of stenosis of the left brachiocephalic vein is shown, where the left superior intercostal vein serves as a collateral. (orig.)

  20. Balloon-occluded retrograde transvenous obliteration of gastric varix draining via the left inferior phrenic vein into the left hepatic vein

    International Nuclear Information System (INIS)

    Ibukuro, Kenji; Mori, Koichi; Tsukiyama, Toshitaka; Inoue, Yoshihiro; Iwamoto, Yukako; Tagawa, Kazumi

    1999-01-01

    We encountered a patient with gastric varix draining not via the usual left suprarenal vein but via the left inferior phrenic vein joining the left hepatic vein. Transfemoral balloon-occluded retrograde transvenous obliteration (BRTO) of the varix was performed under balloon occlusion of the left inferior phrenic vein via the left hepatic vein and retrograde injection of the sclerosing agent (5% of ethanolamine oleate) into the gastric varix. Disappearance of the gastric varix was confirmed on endoscopic examination 2 months later.

  1. Hemoperitoneum due to ruptured paraumbilical vein in a cirrhotic patient with portal hypertension : treatment by means of coil embolization

    International Nuclear Information System (INIS)

    Lee, Jong Myeong; Kim, Hyung Lyul; Lee, Young Hwan; Lee, So Hyun; Kim, Jong Kun

    2000-01-01

    The paraumbilical vein is one of the anastomotic channels between the portal and systemic circulatory systems, and rupture of the intra-abdominal varix is an unusual complication of portal hypertension that can lead to life-threatening hemoperitoneum. We experienced a case of hemoperitoneum due to a ruptured paraumbilical vein revealed by ultrasonography (US), computed tomography (CT) and percutaneous transhepatic portography. The last mentioned demonstrated a dilated paraumbilical vein draining two branches of the left portal vein into the right external iliac vein, and we performed coil embolization at the site at which the presumed site of paraumbilical vein was presumed to cause hemoperitoneum. We describe this this unusual case of hemoperitoneum due to a ruptured paraumbilical vein in a known liver cirrhosis patient in whom portal hypertension was treated by means of coil embolization. (author)

  2. Artificial intelligence system for technical diagnostics of photomasks

    OpenAIRE

    Kozin A. A.; Kozina Yu. Yu.

    2012-01-01

    The developed artificial intelligence system has a high level of noise immunity, so its inclusion in the hardware and software for technical diagnostics of photomasks will reduce the hardware requirements for its execution, and thereby reduce the cost of the complex. As a result it will allow to make a small-scale production profitable.

  3. Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice

    Directory of Open Access Journals (Sweden)

    M. Berner

    Full Text Available : Background: The complication of vein patch rupture is well described after carotid patch angioplasty; however, there is a paucity of data about the safety of vein patch closure in the setting of femoral endarterectomy. Methods/results: From May 2012 to May 2015, 115 femoral endarterectomies with patch closure were performed. A patch rupture occurred in three cases (2.6% with a mortality rate of 66% (2/3. In all cases the greater saphenous vein below the knee was used as patch material. Discussion/conclusion: Vein patches, particularly from small calibre veins, should be excluded in femoral endarterectomy procedures as they pose a substantial risk of rupture. Keywords: Angioplasty, Patch rupture, Femoral artery, Patch, Great saphenous vein

  4. Cognitive Connected Vehicle Information System Design Requirement for Safety: Role of Bayesian Artificial Intelligence

    Directory of Open Access Journals (Sweden)

    Ata Khan

    2013-04-01

    Full Text Available Intelligent transportation systems (ITS are gaining acceptance around the world and the connected vehicle component of ITS is recognized as a high priority research and development area in many technologically advanced countries. Connected vehicles are expected to have the capability of safe, efficient and eco-driving operations whether these are under human control or in the adaptive machine control mode of operations. The race is on to design the capability to operate in connected traffic environment. The operational requirements can be met with cognitive vehicle design features made possible by advances in artificial intelligence-supported methodology, improved understanding of human factors, and advances in communication technology. This paper describes cognitive features and their information system requirements. The architecture of an information system is presented that supports the features of the cognitive connected vehicle. For better focus, information processing capabilities are specified and the role of Bayesian artificial intelligence is defined for data fusion. Example applications illustrate the role of information systems in integrating intelligent technology, Bayesian artificial intelligence, and abstracted human factors. Concluding remarks highlight the role of the information system and Bayesian artificial intelligence in the design of a new generation of cognitive connected vehicle.

  5. Varicose Veins: Role of Mechanotransduction of Venous Hypertension

    Science.gov (United States)

    Atta, Hussein M.

    2012-01-01

    Varicose veins affect approximately one-third of the adult population and result in significant psychological, physical, and financial burden. Nevertheless, the molecular pathogenesis of varicose vein formation remains unidentified. Venous hypertension exerted on veins of the lower extremity is considered the principal factor in varicose vein formation. The role of mechanotransduction of the high venous pressure in the pathogenesis of varicose vein formation has not been adequately investigated despite a good progress in understanding the mechanomolecular mechanisms involved in transduction of high blood pressure in the arterial wall. Understanding the nature of the mechanical forces, the mechanosensors and mechanotransducers in the vein wall, and the downstream signaling pathways will provide new molecular targets for the prevention and treatment of varicose veins. This paper summarized the current understanding of mechano-molecular pathways involved in transduction of hemodynamic forces induced by blood pressure and tries to relate this information to setting of venous hypertension in varicose veins. PMID:22489273

  6. (Mis)placed central venous catheter in the left superior intercostal vein

    International Nuclear Information System (INIS)

    Padovan, Ranka Stern; Paar, Maja Hrabak; Aurer, Igor

    2010-01-01

    Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruction, the tip of the catheter is often seen in collateral mediastinal venous pathways, rather than in the superior vena cava. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. We report a case of 32-year-old female patient with relapsing mediastinal lymphoma and previous superior vena cava obstruction with collateral azygos-hemiazygos venous pathways. The patient had CVC inserted through the left subclavian vein and its position was detected by CT to be in the dilated left superior intercostal vein and accessory hemiazygos vein. Considering that dilated accessory hemiazygos vein can tolerate infusion, the CVC was left in place and the patient had no complaints related to CVC (mal)position. Furthermore, we present anatomical and radiological observations on the azygos-hemiazygos venous system with the special emphasis on the left superior intercostal vein. Non-contrast CT scans can be a valuable imaging tool in the detection of the CVC position, especially in patients with renal insufficiency and contrast media hypersensitivity

  7. Finger vein recognition based on convolutional neural network

    Directory of Open Access Journals (Sweden)

    Meng Gesi

    2017-01-01

    Full Text Available Biometric Authentication Technology has been widely used in this information age. As one of the most important technology of authentication, finger vein recognition attracts our attention because of its high security, reliable accuracy and excellent performance. However, the current finger vein recognition system is difficult to be applied widely because its complicated image pre-processing and not representative feature vectors. To solve this problem, a finger vein recognition method based on the convolution neural network (CNN is proposed in the paper. The image samples are directly input into the CNN model to extract its feature vector so that we can make authentication by comparing the Euclidean distance between these vectors. Finally, the Deep Learning Framework Caffe is adopted to verify this method. The result shows that there are great improvements in both speed and accuracy rate compared to the previous research. And the model has nice robustness in illumination and rotation.

  8. [Deep vein thrombosis prophylaxis.

    Science.gov (United States)

    Sandoval-Chagoya, Gloria Alejandra; Laniado-Laborín, Rafael

    2013-01-01

    Background: despite the proven effectiveness of preventive therapy for deep vein thrombosis, a significant proportion of patients at risk for thromboembolism do not receive prophylaxis during hospitalization. Our objective was to determine the adherence to thrombosis prophylaxis guidelines in a general hospital as a quality control strategy. Methods: a random audit of clinical charts was conducted at the Tijuana General Hospital, Baja California, Mexico, to determine the degree of adherence to deep vein thrombosis prophylaxis guidelines. The instrument used was the Caprini's checklist for thrombosis risk assessment in adult patients. Results: the sample included 300 patient charts; 182 (60.7 %) were surgical patients and 118 were medical patients. Forty six patients (15.3 %) received deep vein thrombosis pharmacologic prophylaxis; 27.1 % of medical patients received deep vein thrombosis prophylaxis versus 8.3 % of surgical patients (p < 0.0001). Conclusions: our results show that adherence to DVT prophylaxis at our hospital is extremely low. Only 15.3 % of our patients at risk received treatment, and even patients with very high risk received treatment in less than 25 % of the cases. We have implemented strategies to increase compliance with clinical guidelines.

  9. The Independent Right and Left Azygos Veins with Hemiazygos Absence: A Rare Case Presentation

    Science.gov (United States)

    Keskin, Suat; Keskin, Zeynep; Sekmenli, Nevin

    2013-01-01

    The veins of the azygos system vary greatly in mode of origin, course, numbers of tributaries and anastomoses, and nature of termination. The azygos vein system can take different courses. Such variation is important in mediastinal surgery, and knowledge of congenital variations can be of clinical importance. It is imperative for reporting radiologists to identify such anomalies. PMID:23841014

  10. Combined central retinal artery and vein occlusion secondary to systemic non-Hodgkin′s lymphoma

    Directory of Open Access Journals (Sweden)

    Shukla Dhananjay

    2006-01-01

    Full Text Available We report a rare case of low-grade systemic B-cell non-Hodgkin′s lymphoma (NHL causing central retinal artery and vein occlusion, which was the only manifestation of disease recurrence. A young man with resolved systemic NHL underwent fluorescein angiography, magnetic resonance imaging and computed tomography to investigate a severe unilateral visual loss. A combined vascular occlusion was observed in the right eye. Neuroimaging detected optic nerve infiltration; but no systemic/ central nervous system involvement was observed. The patient was treated with high-doses of corticosteroids and optic nerve irradiation. The optic neuropathy and vascular occlusion were resistant to treatment. The subsequent neovascular glaucoma was treated by panretinal photocoagulation, which relieved the pain, but vision was not recovered. No further recurrence was observed over the following year.

  11. Dynamic artificial neural networks with affective systems.

    Directory of Open Access Journals (Sweden)

    Catherine D Schuman

    Full Text Available Artificial neural networks (ANNs are processors that are trained to perform particular tasks. We couple a computational ANN with a simulated affective system in order to explore the interaction between the two. In particular, we design a simple affective system that adjusts the threshold values in the neurons of our ANN. The aim of this paper is to demonstrate that this simple affective system can control the firing rate of the ensemble of neurons in the ANN, as well as to explore the coupling between the affective system and the processes of long term potentiation (LTP and long term depression (LTD, and the effect of the parameters of the affective system on its performance. We apply our networks with affective systems to a simple pole balancing example and briefly discuss the effect of affective systems on network performance.

  12. On dynamics of uranium vein mineralization

    International Nuclear Information System (INIS)

    Petrosyan, R.V.

    1981-01-01

    The formation of urnaium vein deposits and the essence of consanguinity of the mineralization and wall metasomatites are considered. The formation of uranium mineralization is analysed from the positions of Korzhinsky D. S. : the formation of metasomatite aureole and associated vein ores take place as a result of the development of one solution flow while the formation of mineral vein associations occurs on the background of contineous filtration of the solution during metasomato is due to a repeated (pulse) half-opening of fractures and their filling with a part of filtrating solution. The analysis of the available information on the example of two different uranium manifestations permits to reveal certain relations both in the character of wall rock alterations and between the metasomatosis and the formation of ore minerals in veins. The conclusion is made that spatial-time correlations of vein formations with wall metasomatites attest that the pulse formation of ores in veinlets occurs on the background and in interrelation with a consecutive precipitation of components in the aureole volume. The analysis of element migration dynamics in wall aureole carried out from the positions of the Korzhinsky hypothesis of the advance wave of acid components that takes into account the interaction of continuous and pulse mechanisms of solution movement permits to avoid contradictions when interpreting the processes of wall rock alterations and vein ore-forming, and permits to make a common scheme of vein ore-genesis [ru

  13. A Morphological Insight of the Femoral Vein

    Directory of Open Access Journals (Sweden)

    Ferreira AH

    2015-10-01

    Full Text Available A total of 13 cadavers (12 men and 1 women of different age group were used for the study with the purpose to determine the prevalence of femoral vein duplication. Lower limb regions (26 sides were carefully dissected as per the standard dissection procedure. Femoral vein (unitruncular was found in 96.15% of specimen. Bitruncular configurations (total bifidity was found in a male cadaver of 75 years of age (3.85%. In the right lower limb, 6.5 cms below the inguinal ligament the femoral vein - lateral ramus received the lateral circumflex femoral vein, and the medial circumflex femoral vein, and the lateral and medial ramii formed a common venous trunk. Knowledge of the truncular venous variations is important to recognize and avoid potential errors in diagnosis of deep venous thrombosis of the femoral vein, in the case of an occluded duplicated trunk.

  14. Artificial intelligence system for technical diagnostics of photomasks

    Directory of Open Access Journals (Sweden)

    Kozin A. A.

    2012-02-01

    Full Text Available The developed artificial intelligence system has a high level of noise immunity, so its inclusion in the hardware and software for technical diagnostics of photomasks will reduce the hardware requirements for its execution, and thereby reduce the cost of the complex. As a result it will allow to make a small-scale production profitable.

  15. Cavernous transformation of the portal vein

    International Nuclear Information System (INIS)

    Lehotska, V.; Dostalova, K.; Durkovsky, A.; Samal, V.

    1995-01-01

    In this contribution, the authors give an account of a rare case of a cavernous transformation of the portal vein that may have originated secondarily in a proliferative hematogenous disease with a polyglobulia and thrombosis in the periferal blood count as well as development of portal hypertension of a prehepatal type. The state of hyper-coagulation in a myeloproliferative disease may have lead to a chronic thrombosis of the portal vein with a subsequent malformation of the portal vein in terms of a cavernous transformation of the portal vein. The case is an interesting one because of the discrepancy between the gravity of the thrombotic complication and slightness of the symptoms in the clinical picture. The authors point out the importance of ultrasonography and computed tomography examination following the intravenous application of a water solution of a contrast medium in a morphologic diagnosing of a rare complication of a chronic thrombotic clot of the portal vein - the cavernous transformation. (authors)

  16. AN ARTIFICIAL INTELLIGENCE-BASED DISTANCE EDUCATION SYSTEM: Artimat

    Directory of Open Access Journals (Sweden)

    Vasif NABIYEV

    2013-04-01

    Full Text Available The purpose of this study is to evaluate the artificial intelligence-based distance education system called as ARTIMAT, which has been prepared in order to improve mathematical problem solving skills of the students, in terms of conceptual proficiency and ease of use with the opinions of teachers and students. The implementation has been performed with 4 teachers and 59 students in 10th grade in an Anatolian High School in Trabzon. Many institutions and organizations in the world approach seriously to distance education besides traditional education. It is inevitable to use the distance education in teaching the problem solving skills in this different dimension of the education. In the studies in Turkey and abroad in the field of mathematics teaching, problem solving skills are generally stated not to be at the desired level and often expressed to have difficulty in teaching. For this reason, difficulties of the students in problem solving have initially been evaluated and the system has been prepared utilizing artificial intelligence algorithms according to the obtained results. In the evaluation of the findings obtained from the application, it has been concluded that the system is responsive to the needs of the students and is successful in general, but that conceptual changes should be made in order that students adapt to the system quickly.

  17. Varicose Vein Treatment (Endovenous Ablation of Varicose Veins)

    Science.gov (United States)

    ... associated veins. top of page What are the benefits vs. risks? Benefits No surgical incision is needed—only a small ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  18. Preduodenal portal vein: its surgical significance.

    Science.gov (United States)

    Makey, D A; Bowen, J C

    1978-11-01

    Preduodenal portal vein is a rare anatomical variant which may be one of many anomalies in the neonate with duodenal "atresia." Preduodenal portal vein also may be an occasional finding in an adult undergoing biliary, gastric, or pancreatic surgery. Awareness and recognition of the anomaly are essential for the avoidance of injury during such operations. We report here a symptomless patient whose preduodenal portal vein was discovered at cholecystectomy.

  19. The effects of vasoactive agents on flow through saphenous vein grafts during lower-extremity peripheral vascular surgery.

    Science.gov (United States)

    Maslow, Andrew D; Bert, Arthur; Slaiby, Jeffrey; Carney, William; Marcaccio, Edward

    2007-06-01

    The purpose of this study was to assess the effects of hemodynamic alterations on vein graft flow during peripheral vascular surgery. It was hypothesized that vasopressors can be administered without compromising flow through the vein grafts. Tertiary care center, university medical center. Randomized placebo-controlled double-blinded study. The effects of phenylephrine, epinephrine, milrinone, intravenous fluid, and placebo on newly constructed peripheral vein grafts were assessed in 60 patients (12 patients in each of 5 groups). Systemic and central hemodynamics were measured by using intra-arterial and pulmonary artery catheters. Vein graft flow was measured by using a transultrasonic flow probe (Transultrasonic Inc, Ithaca, NY). Phenylephrine increased systemic mean blood pressure (mBP) (68.2-94.0 mmHg, p < 0.01), systemic vascular resistance (SVR) (1,091-1,696 dynes x sec x cm(-5), p < 0.001), and vein graft flow (39.5-58.9 mL/min, p < 0.01), whereas cardiac output remained unchanged. Epinephrine resulted in increased cardiac output (4.4-6.9 L/min, p < 0.01) and mBP (72.7-89.1 mmHg, p < 0.01), whereas vein graft flow was reduced in 6 of 12 patients. Intravenous fluid administration resulted in a relatively smaller increase in graft flow (37.6-46.0 mL/min, p < 0.05), an increase in cardiac output, and an insignificant decrease in SVR. Other treatments had either little or no effect on vein graft flow. The study hypothesis was partly supported. Although both phenylephrine and epinephrine increased blood pressure, only the former increased vein graft flow in all patients. In conjunction with increases in graft flow after fluid administration, these data suggest that factors affecting vein graft flow are not just simply related to systemic hemodynamics.

  20. Multimodal ultrasonographic assessment of leiomyosarcoma of the femoral vein in a patient misdiagnosed as having deep vein thrombosis: A case report.

    Science.gov (United States)

    Zhang, Mei; Yan, Feng; Huang, Bin; Wu, Zhoupeng; Wen, Xiaorong

    2017-11-01

    Primary leiomyosarcoma (LMS) of the vein is a rare tumor that arises from the smooth muscle cells of the vessel wall and has an extremely poor prognosis. This tumor can occur in vessels such as the inferior vena cava, great saphenous vein, femoral vein, iliac vein, popliteal vein, and renal vein; the inferior vena cava is the most common site. LMS of the femoral vein can result in edema and pain in the lower extremity; therefore, it is not easy to be differentiated from deep vein thrombosis (DVT). Moreover, virtually no studies have described the ultrasonographic features of LMS of the vein in detail. We present a case of a 55-year-old woman with LMS of the left femoral vein that was misdiagnosed as having deep vein thrombosis (DVT) on initial ultrasonographic examination. The patient began to experience edema and pain in her left leg seven months previously. She was diagnosed as having DVT on initial ultrasonographic examination, but the DVT treatment that she had received for 7 months failed to improve the status of her left lower limb. She subsequently underwent re-examination by means of a multimodal ultrasonographic imaging approach (regular B-mode imaging, color Doppler imaging, pulsed-wave Doppler imaging, contrast-enhanced ultrasonography), which confirmed a diagnosis of LMS. This patient was treated successfully with surgery. This case demonstrates that use of multiple ultrasonographic imaging techniques can be helpful to diagnose LMS accurately. Detection of vasculature in a dilated vein filled with a heterogeneous hypoechoic substance on ultrasonography is a sign of a tumor. The pitfall of misdiagnosing this tumor as DVT is a useful reminder.

  1. Investigation of hindwing folding in ladybird beetles by artificial elytron transplantation and microcomputed tomography.

    Science.gov (United States)

    Saito, Kazuya; Nomura, Shuhei; Yamamoto, Shuhei; Niiyama, Ryuma; Okabe, Yoji

    2017-05-30

    Ladybird beetles are high-mobility insects and explore broad areas by switching between walking and flying. Their excellent wing transformation systems enabling this lifestyle are expected to provide large potential for engineering applications. However, the mechanism behind the folding of their hindwings remains unclear. The reason is that ladybird beetles close the elytra ahead of wing folding, preventing the observation of detailed processes occurring under the elytra. In the present study, artificial transparent elytra were transplanted on living ladybird beetles, thereby enabling us to observe the detailed wing-folding processes. The result revealed that in addition to the abdominal movements mentioned in previous studies, the edge and ventral surface of the elytra, as well as characteristic shaped veins, play important roles in wing folding. The structures of the wing frames enabling this folding process and detailed 3D shape of the hindwing were investigated using microcomputed tomography. The results showed that the tape spring-like elastic frame plays an important role in the wing transformation mechanism. Compared with other beetles, hindwings in ladybird beetles are characterized by two seemingly incompatible properties: ( i ) the wing rigidity with relatively thick veins and ( ii ) the compactness in stored shapes with complex crease patterns. The detailed wing-folding process revealed in this study is expected to facilitate understanding of the naturally optimized system in this excellent deployable structure.

  2. Duplication of the Portal Vein: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Shin, Hyeong Cheol; Jou, Sung Shick; Han, Jong Kyu; Kim, Il Young [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2009-12-15

    The duplication of the portal vein is an uncommon congenital anomaly. To date, only four cases have been reported in the medical literature. This anomaly can cause portal hypertension in pediatric patients. In addition, duplication of the portal vein has various patterns of connection with a splenic vein or mesenteric veins, and it can lie anterior or posterior to the duodenum. We report the MDCT findings of an adult patient with duplication of the portal vein that was found incidentally

  3. Management of Post-Traumatic Phlegmasia Cerulea Dolens via Right-to-Left Femoral Vein to Femoral Vein Bypass (Palma Procedure).

    Science.gov (United States)

    Dua, Anahita; Heller, Jennifer; Lee, Cheong

    2017-11-01

    Phlegmasia cerulea dolens (PCD) is a rare condition resulting from venous occlusion that impairs arterial flow. We report a rare case of post-traumatic PCD after ligation of the iliac vein with successful treatment by right-to-left femoral vein to femoral vein bypass using left great saphenous vein (Palma procedure). The clinical presentation, diagnostic process, and approach to management along with a literature review on the operative management of PCD are presented in this case report.

  4. Absent right superior caval vein in situs solitus

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Sundberg, Karin; Vejlstrup, Niels

    2015-01-01

    Introduction In up to 0.07% of the general population, the right anterior cardinal vein obliterates and the left remains open, creating an absent right superior caval vein and a persistent left superior caval vein. Absent right superior caval vein is associated with additional congenital heart...... disease in about half the patients. We wished to study the consequences of absent right superior caval vein as an incidental finding on prenatal ultrasonic malformation screening. Material and methods This is a retrospective case series study of all foetuses diagnosed with absent right superior caval vein...... no postnatal complications. All children were found to have healthy hearts at follow-up. CONCLUSIONS: In all cases, the findings proved to be a benign condition with no clinical manifestations or complications. Although isolated absent right superior caval vein does not seem to affect the outcome, associated...

  5. Credit Risk Evaluation System For Nigerian Banks Using Artificial Ne

    African Journals Online (AJOL)

    MANKABS

    CREDIT RISK EVALUATION SYSTEM: AN ARTIFICIAL NEURAL NETWORK APPROACH of their own experiential .... limitations concern the high computational ... Number of existing credits at this bank. 7. Personal status and sex. 14. Job. 17.

  6. Finger vein extraction using gradient normalization and principal curvature

    Science.gov (United States)

    Choi, Joon Hwan; Song, Wonseok; Kim, Taejeong; Lee, Seung-Rae; Kim, Hee Chan

    2009-02-01

    Finger vein authentication is a personal identification technology using finger vein images acquired by infrared imaging. It is one of the newest technologies in biometrics. Its main advantage over other biometrics is the low risk of forgery or theft, due to the fact that finger veins are not normally visible to others. Extracting finger vein patterns from infrared images is the most difficult part in finger vein authentication. Uneven illumination, varying tissues and bones, and changes in the physical conditions and the blood flow make the thickness and brightness of the same vein different in each acquisition. Accordingly, extracting finger veins at their accurate positions regardless of their thickness and brightness is necessary for accurate personal identification. For this purpose, we propose a new finger vein extraction method which is composed of gradient normalization, principal curvature calculation, and binarization. As local brightness variation has little effect on the curvature and as gradient normalization makes the curvature fairly uniform at vein pixels, our method effectively extracts finger vein patterns regardless of the vein thickness or brightness. In our experiment, the proposed method showed notable improvement as compared with the existing methods.

  7. Adventitial cystic disease of the common femoral vein presenting as deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Young-Kyun Kim

    2016-07-01

    Full Text Available Adventitial cystic disease of the common femoral vein is a rare condition. We herein report the case of a 50-year-old woman who presented with painless swelling in her left lower leg that resembled deep vein thrombosis. She underwent femoral exploration and excision of the cystic wall. The presentation, investigation, treatment, and pathology of this condition are discussed with a literature review.

  8. A Model of Artificial Genotype and Norm of Reaction in a Robotic System

    OpenAIRE

    Durán Bosch, Ángel Juan; Pascual del Pobil Ferré, Ángel

    2016-01-01

    The genes of living organisms serve as large stores of information for replicating their behavior and morphology over generations. The evolutionary view of genetics that has inspired artificial systems with a Mendelian approach does not take into account the interaction between species and with the environment to generate a particular phenotype. In this paper, a genotype model is suggested to shape the relationship with the phenotype and the environment in an artificial system. A method to ob...

  9. Nucleocytoplasmic Transport: A Paradigm for Molecular Logistics in Artificial Systems.

    Science.gov (United States)

    Vujica, Suncica; Zelmer, Christina; Panatala, Radhakrishnan; Lim, Roderick Y H

    2016-01-01

    Artificial organelles, molecular factories and nanoreactors are membrane-bound systems envisaged to exhibit cell-like functionality. These constitute liposomes, polymersomes or hybrid lipo-polymersomes that display different membrane-spanning channels and/or enclose molecular modules. To achieve more complex functionality, an artificial organelle should ideally sustain a continuous influx of essential macromolecular modules (i.e. cargoes) and metabolites against an outflow of reaction products. This would benefit from the incorporation of selective nanopores as well as specific trafficking factors that facilitate cargo selectivity, translocation efficiency, and directionality. Towards this goal, we describe how proteinaceous cargoes are transported between the nucleus and cytoplasm by nuclear pore complexes and the biological trafficking machinery in living cells (i.e. nucleocytoplasmic transport). On this basis, we discuss how biomimetic control may be implemented to selectively import, compartmentalize and accumulate diverse macromolecular modules against concentration gradients in artificial organelles.

  10. Using Artificial Intelligence Techniques to Implement a Multifactor Authentication System

    Directory of Open Access Journals (Sweden)

    Jackson Phiri

    2011-08-01

    Full Text Available The recent years have seen a rise in the number of cases of cyber-crime committed through identity theft and fraud. To address this problem, this paper uses adaptive neural-fuzzy inference system, fuzzy logic and artificial neural network to implement a multifactor authentication system through a technique of information fusion. To begin with, the identity attributes are mined using the three corpora from three major sources namely the social networks, a set of questionnaires and application forms from the various services offered both in the real and cyberspace. The statistical information generated by the corpora is then used to compose an identity attribute metric model. The composed identity attributes metrics values classified as biometrics, device metrics and pseudo metrics are then fused at the score level through a technique of information fusion in a multifactor authentication system by using each of the above artificial intelligence technologies and the results compared.

  11. Applications Of Artificial Intelligence In Control System Analysis And Design

    Science.gov (United States)

    Birdwell, J. D.

    1987-10-01

    To date, applications of artificial intelligence in control system analysis and design are primarily associated with the design process. These applications take the form of knowledge bases incorporating expertise on a design method, such as multivariable linear controller design, or on a field such as identification. My experience has demonstrated that, while such expert systems are useful, perhaps a greater benefit will come from applications in the maintenance of technical databases, as are found in real-time data acquisition systems, and of modeling and design databases, which represent the status of a computer-aided design process for a human user. This reflects the observation that computers are best at maintaining relations about large sets of objects, whereas humans are best at maintaining knowledge of depth, as occurs when a design option involving a sequence of steps is explored. This paper will discuss some of these issues, and will provide some examples which illustrate the potential of artificial intelligence.

  12. Personal authentication through dorsal hand vein patterns

    Science.gov (United States)

    Hsu, Chih-Bin; Hao, Shu-Sheng; Lee, Jen-Chun

    2011-08-01

    Biometric identification is an emerging technology that can solve security problems in our networked society. A reliable and robust personal verification approach using dorsal hand vein patterns is proposed in this paper. The characteristic of the approach needs less computational and memory requirements and has a higher recognition accuracy. In our work, the near-infrared charge-coupled device (CCD) camera is adopted as an input device for capturing dorsal hand vein images, it has the advantages of the low-cost and noncontact imaging. In the proposed approach, two finger-peaks are automatically selected as the datum points to define the region of interest (ROI) in the dorsal hand vein images. The modified two-directional two-dimensional principal component analysis, which performs an alternate two-dimensional PCA (2DPCA) in the column direction of images in the 2DPCA subspace, is proposed to exploit the correlation of vein features inside the ROI between images. The major advantage of the proposed method is that it requires fewer coefficients for efficient dorsal hand vein image representation and recognition. The experimental results on our large dorsal hand vein database show that the presented schema achieves promising performance (false reject rate: 0.97% and false acceptance rate: 0.05%) and is feasible for dorsal hand vein recognition.

  13. Thrombosis of right ovarian vein

    International Nuclear Information System (INIS)

    Forner, J.; Talens, A.; Flores, M.; Mendez, M.

    2001-01-01

    Ovarian vein thrombosis is a rare postpartum complication (0.1%). It can be fatal, since it can lead to sepsis, pulmonary thromboembolisms and inferior vena cava or renal vein thrombosis. Computed tomography and magnetic resonance imaging are the techniques of choice for its diagnosis, while the value of ultrasound is limited due to its low sensitivity and specificity. We report the case of a woman who, during puerperium, developed thrombosis of right ovarian vein that presented clinical, ultrasonographic and computed tomographic features of appendicitis. We describe the radiological sings and stress the fact that this diagnosis should be suspected in puerperal women. (Author) 9 refs

  14. A Multiuser Detector Based on Artificial Bee Colony Algorithm for DS-UWB Systems

    Directory of Open Access Journals (Sweden)

    Zhendong Yin

    2013-01-01

    Full Text Available Artificial Bee Colony (ABC algorithm is an optimization algorithm based on the intelligent behavior of honey bee swarm. The ABC algorithm was developed to solve optimizing numerical problems and revealed premising results in processing time and solution quality. In ABC, a colony of artificial bees search for rich artificial food sources; the optimizing numerical problems are converted to the problem of finding the best parameter which minimizes an objective function. Then, the artificial bees randomly discover a population of initial solutions and then iteratively improve them by employing the behavior: moving towards better solutions by means of a neighbor search mechanism while abandoning poor solutions. In this paper, an efficient multiuser detector based on a suboptimal code mapping multiuser detector and artificial bee colony algorithm (SCM-ABC-MUD is proposed and implemented in direct-sequence ultra-wideband (DS-UWB systems under the additive white Gaussian noise (AWGN channel. The simulation results demonstrate that the BER and the near-far effect resistance performances of this proposed algorithm are quite close to those of the optimum multiuser detector (OMD while its computational complexity is much lower than that of OMD. Furthermore, the BER performance of SCM-ABC-MUD is not sensitive to the number of active users and can obtain a large system capacity.

  15. ANUBIS: artificial neuromodulation using a Bayesian inference system.

    Science.gov (United States)

    Smith, Benjamin J H; Saaj, Chakravarthini M; Allouis, Elie

    2013-01-01

    Gain tuning is a crucial part of controller design and depends not only on an accurate understanding of the system in question, but also on the designer's ability to predict what disturbances and other perturbations the system will encounter throughout its operation. This letter presents ANUBIS (artificial neuromodulation using a Bayesian inference system), a novel biologically inspired technique for automatically tuning controller parameters in real time. ANUBIS is based on the Bayesian brain concept and modifies it by incorporating a model of the neuromodulatory system comprising four artificial neuromodulators. It has been applied to the controller of EchinoBot, a prototype walking rover for Martian exploration. ANUBIS has been implemented at three levels of the controller; gait generation, foot trajectory planning using Bézier curves, and foot trajectory tracking using a terminal sliding mode controller. We compare the results to a similar system that has been tuned using a multilayer perceptron. The use of Bayesian inference means that the system retains mathematical interpretability, unlike other intelligent tuning techniques, which use neural networks, fuzzy logic, or evolutionary algorithms. The simulation results show that ANUBIS provides significant improvements in efficiency and adaptability of the three controller components; it allows the robot to react to obstacles and uncertainties faster than the system tuned with the MLP, while maintaining stability and accuracy. As well as advancing rover autonomy, ANUBIS could also be applied to other situations where operating conditions are likely to change or cannot be accurately modeled in advance, such as process control. In addition, it demonstrates one way in which neuromodulation could fit into the Bayesian brain framework.

  16. Anomlus pulmonary venous return aaccompanied by normal superior pulmonary veins in the left upper lobe: A case report

    International Nuclear Information System (INIS)

    Kim, Dong Eon; Kang, Min Jin; Lee, Ji Hae; Bae, Kyung Eun; Kim, Jae Hyung; Kang, Tae Kyung; Kim, Soung Hee; Kim, Ji Young; Jeong, Myeong Ja; Kim, Soo Hyun

    2017-01-01

    Partial anomalous pulmonary venous return is a rare congenital pulmonary venous anomaly, in which some of the pulmonary veins drain into the systemic circulation rather than the left atrium. Many variants of partial anomalous pulmonary venous return have been reported. We present a rare type of partial anomalous pulmonary venous return in which the anomalous left upper lobe pulmonary vein drained into the left innominate vein via the vertical vein, accompanying the left upper lobe pulmonary vein in the normal location

  17. Anomlus pulmonary venous return aaccompanied by normal superior pulmonary veins in the left upper lobe: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Eon; Kang, Min Jin; Lee, Ji Hae; Bae, Kyung Eun; Kim, Jae Hyung; Kang, Tae Kyung; Kim, Soung Hee; Kim, Ji Young; Jeong, Myeong Ja; Kim, Soo Hyun [Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2017-08-15

    Partial anomalous pulmonary venous return is a rare congenital pulmonary venous anomaly, in which some of the pulmonary veins drain into the systemic circulation rather than the left atrium. Many variants of partial anomalous pulmonary venous return have been reported. We present a rare type of partial anomalous pulmonary venous return in which the anomalous left upper lobe pulmonary vein drained into the left innominate vein via the vertical vein, accompanying the left upper lobe pulmonary vein in the normal location.

  18. Rule-based model of vein graft remodeling.

    Directory of Open Access Journals (Sweden)

    Minki Hwang

    Full Text Available When vein segments are implanted into the arterial system for use in arterial bypass grafting, adaptation to the higher pressure and flow of the arterial system is accomplished thorough wall thickening and expansion. These early remodeling events have been found to be closely coupled to the local hemodynamic forces, such as shear stress and wall tension, and are believed to be the foundation for later vein graft failure. To further our mechanistic understanding of the cellular and extracellular interactions that lead to global changes in tissue architecture, a rule-based modeling method is developed through the application of basic rules of behaviors for these molecular and cellular activities. In the current method, smooth muscle cell (SMC, extracellular matrix (ECM, and monocytes are selected as the three components that occupy the elements of a grid system that comprise the developing vein graft intima. The probabilities of the cellular behaviors are developed based on data extracted from in vivo experiments. At each time step, the various probabilities are computed and applied to the SMC and ECM elements to determine their next physical state and behavior. One- and two-dimensional models are developed to test and validate the computational approach. The importance of monocyte infiltration, and the associated effect in augmenting extracellular matrix deposition, was evaluated and found to be an important component in model development. Final model validation is performed using an independent set of experiments, where model predictions of intimal growth are evaluated against experimental data obtained from the complex geometry and shear stress patterns offered by a mid-graft focal stenosis, where simulation results show good agreements with the experimental data.

  19. The role of artificial intelligence and expert systems in increasing STS operations productivity

    Science.gov (United States)

    Culbert, C.

    1985-01-01

    Artificial Intelligence (AI) is discussed. A number of the computer technologies pioneered in the AI world can make significant contributions to increasing STS operations productivity. Application of expert systems, natural language, speech recognition, and other key technologies can reduce manpower while raising productivity. Many aspects of STS support lend themselves to this type of automation. The artificial intelligence section of the mission planning and analysis division has developed a number of functioning prototype systems which demonstrate the potential gains of applying AI technology.

  20. An artificial neural network for modeling reliability, availability and maintainability of a repairable system

    International Nuclear Information System (INIS)

    Rajpal, P.S.; Shishodia, K.S.; Sekhon, G.S.

    2006-01-01

    The paper explores the application of artificial neural networks to model the behaviour of a complex, repairable system. A composite measure of reliability, availability and maintainability parameters has been proposed for measuring the system performance. The artificial neural network has been trained using past data of a helicopter transportation facility. It is used to simulate behaviour of the facility under various constraints. The insights obtained from results of simulation are useful in formulating strategies for optimal operation of the system

  1. Deep vein thrombosis: a clinical review

    Directory of Open Access Journals (Sweden)

    Kesieme EB

    2011-04-01

    Full Text Available Emeka Kesieme1, Chinenye Kesieme2, Nze Jebbin3, Eshiobo Irekpita1, Andrew Dongo11Department of Surgery, Irrua Specialist Teaching Hospital, Irrua, Nigeria; 2Department of Paediatrics, Irrua Specialist Teaching Hospital, Irrua, Nigeria; 3Department of Surgery, University of Port Harcourt Teaching Hospital, Port-Harcourt, NigeriaBackground: Deep vein thrombosis (DVT is the formation of blood clots (thrombi in the deep veins. It commonly affects the deep leg veins (such as the calf veins, femoral vein, or popliteal vein or the deep veins of the pelvis. It is a potentially dangerous condition that can lead to preventable morbidity and mortality.Aim: To present an update on the causes and management of DVT.Methods: A review of publications obtained from Medline search, medical libraries, and Google.Results: DVT affects 0.1% of persons per year. It is predominantly a disease of the elderly and has a slight male preponderance. The approach to making a diagnosis currently involves an algorithm combining pretest probability, D-dimer testing, and compression ultrasonography. This will guide further investigations if necessary. Prophylaxis is both mechanical and pharmacological. The goals of treatment are to prevent extension of thrombi, pulmonary embolism, recurrence of thrombi, and the development of complications such as pulmonary hypertension and post-thrombotic syndrome.Conclusion: DVT is a potentially dangerous condition with a myriad of risk factors. Prophylaxis is very important and can be mechanical and pharmacological. The mainstay of treatment is anticoagulant therapy. Low-molecular-weight heparin, unfractionated heparin, and vitamin K antagonists have been the treatment of choice. Currently anticoagulants specifically targeting components of the common pathway have been recommended for prophylaxis. These include fondaparinux, a selective indirect factor Xa inhibitor and the new oral selective direct thrombin inhibitors (dabigatran and selective

  2. Dual Balloon-Occluded Retrograde Transvenous Obliteration of Gastric Varix Draining into the Left Adrenal Vein and Left Inferior Phrenic Vein

    International Nuclear Information System (INIS)

    Nishida, Norifumi; Ninoi, Teruhisa; Kitayama, Toshiaki; Yamamoto, Akira; Sakai, Yukimasa; Sato, Kimihiko; Hamuro, Masao; Nakamura, Kenji; Inoue, Yuichi; Yamada, Ryusaku

    2004-01-01

    A 66-year-old woman with a gastric varix, draining into a dilated left adrenal vein and a left inferior phrenic vein, was treated with dual balloon-occluded retrograde transvenous obliteration (B-RTO). Under balloon occlusion of the left adrenal vein and the left inferior phrenic vein, retrograde injection of a sclerosant (5% ethanolamine oleate) into the gastric varix was performed. Two weeks later, disappearance of flow in the gastric varix was confirmed on endoscopic ultrasound examination

  3. Computer-aided N. M. R. spectra interpretation. I. An artificial intelligence system

    Energy Technology Data Exchange (ETDEWEB)

    Vida, M [Central N.M.R. Laboratory, Slovak Technical University, Bratislava (Czechoslovakia)

    1980-03-01

    Some desirable hardware and software features of an artificial intelligence system tailored to the needs of a modern computerized n.m.r. laboratory are discussed. A system corresponding to this idea is described.

  4. The identification of conduction gaps after pulmonary vein isolation using a new electroanatomic mapping system.

    Science.gov (United States)

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2017-11-01

    The reconnection of left atrial-pulmonary vein (LA-PV) conduction after the initial procedure of pulmonary vein (PV) isolation is not rare, and is one of the main cause of atrial fibrillation (AF) recurrence after PV isolation. We investigated feasibility of a new ultrahigh-resolution mapping system using a 64-pole small basket catheter for the identification of LA-PV conduction gaps. This prospective study included 31 consecutive patients (20 with persistent AF) undergoing a second ablation after a PV isolation procedure with LA-PV reconnected conduction at any of the 4 PVs. An LA-PV map was created using the mapping system, and ablation was performed at the estimated gap location. The propagation map identified 54 gaps from 39 ipsilateral PV pairs, requiring manual electrogram reannotation for 23 gaps (43%). Gaps at the anterior and carinal regions of left and right ipsilateral PVs required manual electrogram reannotation more frequently than the other regions. The voltage map could identify the gap only in 19 instances (35%). Electrophysiological properties of the gaps (multiple gaps in the same ipsilateral PVs, conduction time, velocity, width, and length) did not differ between those needing and not needing manual electrogram reannotation. During the gap ablation, either the activation sequence alteration or elimination of PV potentials was observed using a circular catheter placed in the PV, suggesting that all the identified gaps were correct. This new electroanatomic mapping system visualized all the LA-PV gaps in patients undergoing a second AF ablation. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Recurrence of superficial vein thrombosis in patients with varicose veins.

    Science.gov (United States)

    Karathanos, Christos; Spanos, Konstantinos; Saleptsis, Vassileios; Tsezou, Aspasia; Kyriakou, Despina; Giannoukas, Athanasios D

    2016-08-01

    To investigate which factors other than history of superficial vein thrombosis (SVT) are associated with recurrent spontaneous SVT episodes in patients with varicose veins (VVs). Patients with a history of spontaneous SVT and VVs were followed up for a mean period of 55 months. Demographics, comorbidities, and thrombophilia screening test were analyzed. Patients were grouped according to the clinical-etiology-anatomy-pathophysiology classification. A multiple logistic regression analysis with the forward likelihood ratio method was undertaken. Thirteen patients out of 97 had a recurrence SVT episode during the follow-up period. All those patients were identified to have a thrombophilia defect. Protein C and S, antithrombin, and plasminogen deficiencies were more frequently present in patients without recurrence. Gene mutations were present in 38% in the nonrecurrence group and 77% in the recurrence group. After logistic regression analysis, patients with dislipidemia and mutation in prothrombin G20210A (FII) had an increased risk for recurrence by 5.4-fold and 4.6-fold, respectively. No deep vein thrombosis or pulmonary embolism occurred. Dislipidemia and gene mutations of F II are associated with SVT recurrence in patients with VVs. A selection of patients may benefit from anticoagulation in the short term and from VVs intervention in the long term. © The Author(s) 2015.

  6. A Framework for Intelligent Instructional Systems: An Artificial Intelligence Machine Learning Approach.

    Science.gov (United States)

    Becker, Lee A.

    1987-01-01

    Presents and develops a general model of the nature of a learning system and a classification for learning systems. Highlights include the relationship between artificial intelligence and cognitive psychology; computer-based instructional systems; intelligent instructional systems; and the role of the learner's knowledge base in an intelligent…

  7. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  8. Endovenous mechanochemical ablation of great saphenous vein incompetence using the ClariVein device: a safety study

    NARCIS (Netherlands)

    Eekeren, R. van; Boersma, D.; Elias, S.; Holewijn, S.; Werson, D.A.; Vries, J.P. de; Reijnen, M.M.P.J.

    2011-01-01

    PURPOSE: To evaluate the feasibility and safety of endovenous mechanochemical ablation (MOCA) for the treatment of great saphenous vein (GSV) incompetence. METHODS: The newly developed ClariVein device uses a technique that combines mechanical endothelial damage using a rotating wire with the

  9. Primary Iliac Venous Leiomyosarcoma: A Rare Cause of Deep Vein Thrombosis in a Young Patient

    Directory of Open Access Journals (Sweden)

    Nelson Oliveira

    2011-01-01

    Full Text Available Introduction. Primary venous tumours are a rare cause of deep vein thrombosis. The authors present a case where the definitive diagnosis was delayed by inconclusive complementary imaging. Clinical Case. A thirty-seven-year-old female presented with an iliofemoral venous thrombosis of the right lower limb. The patient had presented with an episode of femoral-popliteal vein thrombosis five months before and was currently under anticoagulation. Phlegmasia alba dolens installed progressively, as thrombus rapidly extended to the inferior vena cava despite systemic thrombolysis and anticoagulation. Diagnostic imaging failed to identify the underlying aetiology of the deep vein thrombosis. The definitive diagnosis of primary venous leiomyosarcoma was reached by a subcutaneous abdominal wall nodule biopsy. Conclusion. Primary venous leiomyosarcoma of the iliac vein is a rare cause of deep vein thrombosis, which must be considered in young patients with recurrent or refractory to treatment deep vein thrombosis.

  10. Gd-DTPA-enhanced MR venography for varicose veins of the calf

    International Nuclear Information System (INIS)

    Kohata, Yoshiko; Naito, Akira; Ito, Katuhide.

    1995-01-01

    2D time-of-flight MR venography (2D TOF MRV) was performed in 16 patients (25 calves) with varicose veins and 2 volunteers (4 calves), and compared with venography. Sequential SPGR (TR/TE/FA=45 ms/7 ms/60deg) transverse images and/or GRASS (TR/TE/FA=100 ms/13 ms/60deg) transverse images were obtained for MRV. Superior presaturation pulse (S-SAT) was placed in 21 calves, and 0.05 mmol/kg Gd-DTPA was used in all calves. Projection MRVs were generated with maximum intensity projection (MIP) reconstruction. Regarding sequence parameter, S-SAT was useful to eliminate signal from artery that would obscure the signal of deep veins. The detectability of deep veins was improved with the use of S-SAT. In the comparison with venography, MRV could more clearly demonstrate varicose veins more than 5 mm in diameter and their drainage veins than venography. But it could not so clearly demonstrate deep veins as venography. It could not detect fine varicose veins less than 5 mm in diameter and connecting veins with valve insufficiency. In the examination of varicose veins, detection of deep veins, large varicose veins and their main drainage veins is clinically important, because diagnosis of patency of deep veins and dilatation of the drainage veins is necessary to choose the treatment, concluding conservative therapy, stripping and sclerotherapy. However, detection of fine varicose veins and connecting veins are not so important because those veins seldom need treatment. MRV was not so suitable for detection of deep veins, but very useful for detection of varicose veins more than 5 mm in diameter and their main drainage veins. In conclusion, MRV is non-invasive and effective method in varicose veins of calf, and it can take the place of venography with the improvement of deep vein detectability. (author)

  11. Artificial Immune Systems as a Modern Tool for Solving Multi-Purpose Optimization Tasks in the Field of Logistics

    Directory of Open Access Journals (Sweden)

    Skitsko Volodymyr I.

    2017-03-01

    Full Text Available The article investigates various aspects of the functioning of artificial immune systems and their using to solve different tasks. The analysis of the studied literature showed that nowadays there exist combinations of artificial immune systems, in particular with genetic algorithms, the particle swarm optimization method, artificial neural networks, etc., to solve different tasks. However, the solving of economic tasks is paid little attention. The article presents the basic terminology of artificial immune systems; the steps of the clonal selection algorithm are described, as well as a brief description of the negative selection algorithm, the immune network algorithm and the dendritic algorithm is given; conceptual aspects of the use of an artificial immune system for solving multi-purpose optimization problems are formulated, and an example of solving a problem in the field of logistics is described. Artificial immune systems as a means of solving various weakly structured, multi-criteria and multi-purpose economic tasks, in particular in the sphere of logistics, are a promising tool that requires further research. Therefore, it is advisable in the future to focus on the use of various existing immune algorithms for solving various economic problems.

  12. Bilateral anomalous drainage of the posterior divisions of renal veins into the azygos venous system in a 20-year-old woman: a case report.

    Science.gov (United States)

    Pallangyo, Pedro; Lyimo, Frederick; Nicholaus, Paulina; Masatu, Stephano; Janabi, Mohamed

    2016-12-03

    Renal vein anomalies are relatively infrequent and generally asymptomatic. Preoperative knowledge of such variants is, however, of paramount importance in several angiographic and surgical procedures including renal venography, renal vein sampling, spermatic embolization, and renal transplantation. Inadequate knowledge and failure to recognize such anatomic variations may lead to several operative hazards including hemorrhage, nephrectomy, and even death. We report a case of bilateral anomalous drainage of the posterior divisions of renal veins into the azygos venous system in a 20-year-old woman of African descent from Tanzania who presented to us with a 12-year history of recurrent anemia. She had anemia, a positive sickling test, and hemoglobin electrophoresis revealed a sickle cell trait (AS). She underwent computed tomography angiography of her chest and abdomen to rule out the presence of arteriovenous malformations. Aortography findings were normal but venography results revealed features of tortuously dilated azygos and hemiazygos veins each receiving blood from its respective posterior division of renal vein. Although venous anomalies are relatively infrequent and generally lack a clinical significance, a thorough understanding of embryologic development and its associated errors is of immense importance in equipping angiographers and surgeons to select appropriate interventional/operative techniques, anticipate risks, and prevent intervention-related complications.

  13. Leiomyosarcoma of the renal vein

    Directory of Open Access Journals (Sweden)

    Lemos Gustavo C.

    2003-01-01

    Full Text Available Leiomyosarcoma of the renal vein is a rare tumor of complex diagnosis. We presented a case of renal vein leiomyosarcoma detected in a routine study. The primary treatment was complete surgical removal of the mass. In cases where surgical removal is not possible the prognosis is poor, with high rates of local recurrence and distant spread.

  14. Artificial Intelligence Systems as Prognostic and Predictive Tools in Ovarian Cancer.

    Science.gov (United States)

    Enshaei, A; Robson, C N; Edmondson, R J

    2015-11-01

    The ability to provide accurate prognostic and predictive information to patients is becoming increasingly important as clinicians enter an era of personalized medicine. For a disease as heterogeneous as epithelial ovarian cancer, conventional algorithms become too complex for routine clinical use. This study therefore investigated the potential for an artificial intelligence model to provide this information and compared it with conventional statistical approaches. The authors created a database comprising 668 cases of epithelial ovarian cancer during a 10-year period and collected data routinely available in a clinical environment. They also collected survival data for all the patients, then constructed an artificial intelligence model capable of comparing a variety of algorithms and classifiers alongside conventional statistical approaches such as logistic regression. The model was used to predict overall survival and demonstrated that an artificial neural network (ANN) algorithm was capable of predicting survival with high accuracy (93 %) and an area under the curve (AUC) of 0.74 and that this outperformed logistic regression. The model also was used to predict the outcome of surgery and again showed that ANN could predict outcome (complete/optimal cytoreduction vs. suboptimal cytoreduction) with 77 % accuracy and an AUC of 0.73. These data are encouraging and demonstrate that artificial intelligence systems may have a role in providing prognostic and predictive data for patients. The performance of these systems likely will improve with increasing data set size, and this needs further investigation.

  15. Stellar Image Interpretation System using Artificial Neural Networks: Unipolar Function Case

    Directory of Open Access Journals (Sweden)

    F. I. Younis

    2001-01-01

    Full Text Available An artificial neural network based system for interpreting astronomical images has been developed. The system is based on feed-forward Artificial Neural Networks (ANNs with error back-propagation learning. Knowledge about images of stars, cosmic ray events and noise found in images is used to prepare two sets of input patterns to train and test our approach. The system has been developed and implemented to scan astronomical digital images in order to segregate stellar images from other entities. It has been coded in C language for users of personal computers. An astronomical image of a star cluster from other objects is undertaken as a test case. The obtained results are found to be in very good agreement with those derived from the DAOPHOTII package, which is widely used in the astronomical community. It is proved that our system is simpler, much faster and more reliable. Moreover, no prior knowledge, or initial data from the frame to be analysed is required.

  16. Ultrasound assessment of great saphenous vein insufficiency

    Directory of Open Access Journals (Sweden)

    Chander RK

    2015-06-01

    Full Text Available Rajiv K Chander,1 Thomas S Monahan1,2 1Section of Vascular Surgery, Department of Surgery, University of Maryland School of Medicine, 2Department of Surgery, Baltimore Veterans Affairs Medical Center, Baltimore, MD, USA Abstract: Duplex ultrasonography is the ideal modality to assess great saphenous vein insufficiency. Duplex ultrasonography incorporates both gray scale images to delineate anatomy and color-Doppler imaging that visualizes the flow of blood in a structure. Assessment of great saphenous vein requires definition of the anatomy, augmentation of flow, evaluation for both superficial and deep vein thrombosis, and determining the presence of reflux. Currently, evolution in the treatment of reflux also relies on ultrasound for the treatment of the disease. Understanding the utilization of the ultrasound for the diagnosis and treatment of greater saphenous vein reflux is important for practitioners treating reflux disease. Keywords: duplex ultrasonography, small saphenous vein 

  17. [Artificial intelligence] AI for protection systems

    Energy Technology Data Exchange (ETDEWEB)

    Aggarwal, R.; Johns, A.

    1997-12-31

    The reliable operation of large power systems with small stability margins is highly dependent on control systems and protection devices. Progress in the field of microprocessor systems and demanding requirements in respect of the performance of protective relays are the reasons for digital device applications to power system protection. The superiority of numeric protection over its analogue alternatives is attributed to such factors as accurate extraction of the fundamental voltage and current components through filtering, functional benefits resulting from multi-processor design and extensive self-monitoring, etc. However, all these reasons have not led to a major impact on speed, sensitivity and selectivity of primary protective relays, and the gains are only marginal; this is so because conventional digital relays still rely on deterministic signal models and a heuristic approach for decision making, so that only a fraction of the information contained within voltage and current signals as well as knowledge about the plant to be protected is used. The performance of digital relays may be substantially improved if the decision making is based on elements of artificial intelligence (AI). (Author)

  18. Artificial neural network-aided image analysis system for cell counting.

    Science.gov (United States)

    Sjöström, P J; Frydel, B R; Wahlberg, L U

    1999-05-01

    In histological preparations containing debris and synthetic materials, it is difficult to automate cell counting using standard image analysis tools, i.e., systems that rely on boundary contours, histogram thresholding, etc. In an attempt to mimic manual cell recognition, an automated cell counter was constructed using a combination of artificial intelligence and standard image analysis methods. Artificial neural network (ANN) methods were applied on digitized microscopy fields without pre-ANN feature extraction. A three-layer feed-forward network with extensive weight sharing in the first hidden layer was employed and trained on 1,830 examples using the error back-propagation algorithm on a Power Macintosh 7300/180 desktop computer. The optimal number of hidden neurons was determined and the trained system was validated by comparison with blinded human counts. System performance at 50x and lO0x magnification was evaluated. The correlation index at 100x magnification neared person-to-person variability, while 50x magnification was not useful. The system was approximately six times faster than an experienced human. ANN-based automated cell counting in noisy histological preparations is feasible. Consistent histology and computer power are crucial for system performance. The system provides several benefits, such as speed of analysis and consistency, and frees up personnel for other tasks.

  19. Artificial Intelligence and Moral intelligence

    OpenAIRE

    Laura Pana

    2008-01-01

    We discuss the thesis that the implementation of a moral code in the behaviour of artificial intelligent systems needs a specific form of human and artificial intelligence, not just an abstract intelligence. We present intelligence as a system with an internal structure and the structural levels of the moral system, as well as certain characteristics of artificial intelligent agents which can/must be treated as 1- individual entities (with a complex, specialized, autonomous or selfdetermined,...

  20. Proposal of a framework for solving human factors of artificial systems and its application to maintenance work

    International Nuclear Information System (INIS)

    Nagamatsu, Takashi; Otsuji, Tomoo; Yoshikawa, Hidekazu; Shiba, Shigenari

    2004-01-01

    A framework for solving human factors of artificial systems is proposed in this study, where a whole system of machines and the human organization that involves in the operation and management of machines is defined as an 'artificial system'. Five aspects of human factors in the artificial system are first discussed, and the types of artificial system with respect to the human factors are divided into three levels from a viewpoint of complexity. A framework that can treat artificial systems by unified methodology has been proposed for treating both the complexity level and the different kinds of human factors. As a concrete example of this framework application, a prototype system has been developed for advanced plant maintenance support by using ES-HMD (Eye Sensing-Head Mounted Display). This is a remote communication system of cooperative maintenance work between the expert in a remote support center and the maintenance worker at a certain machine in the plant site to conduct a complicated task without committing human error. It was confirmed by laboratory experiment that the expert would instruct the worker so that he or she could perform the task successfully, by observing the worker's eye gazing point and by pointing the right place of action on the transferred display of the worker's eyesight through the ES-MHD. (author)

  1. Gonadal vein tumor thrombosis due to renal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Hamidreza Haghighatkhah

    2015-01-01

    Full Text Available Renal cell carcinoma (RCC had a tendency to extend into the renal vein and inferior vena cava, while extension into the gonadal vein has been rarely reported. Gonadal vein tumor thrombosis appears as an enhancing filling defect within the dilated gonadal vein anterior to the psoas muscle and shows an enhancement pattern identical to that of the original tumor. The possibility of gonadal vein thrombosis should be kept in mind when looking at an imaging study of patients with RCC

  2. Identifikasi Pepper vein yellows virus yang Berasosiasi dengan Penyakit Yellow Vein Banding pada Tanaman Mentimun di Bali

    Directory of Open Access Journals (Sweden)

    I Dewa Nyoman Nyana

    2016-11-01

    Full Text Available Yellowing vein banding disease has been reported infecting cucurbit plants in Bali since 2014. Similar vein banding symptom on chilli pepper was observed previously, and early diagnosis indicated infection of Polerovirus. The objective of this research was to confirm the presence of Polerovirus infection on cucumber plant showing yellow vein banding symptom in Bali. Reverse transcription polymerase chain reaction – based detection method was conducted using specific primer pairs PeVYV-CP-F-BamH1/ PeVYV-CP-R-Pst1followed by sequencing and nucleotide sequence analysis.  Specific DNA fragments of ± 650 bp was successfully amplified from field samples.  Nucleotide sequence analysis showed that the sequence has the highest similarity > 95% with Pepper vein yellow virus (PeVYV infecting chili pepper from Indonesia (Bali, and Rembang, Japan, and Greece.

  3. Theory and applications of artificial endocrine system-an overview

    Institute of Scientific and Technical Information of China (English)

    CUI Wei; QIANG Sheng; GAO X Z

    2006-01-01

    Inspired by the biological endocrine system, the Artificial Endocrine System (AES) has been proposed and investigated during the past decade. As a novel branch of computational intelligence methods, it has its unique and distinguishing features. This paper intends to give an overview of the current research work in the AES. The preliminary theory of the AES, which is based on the simplified mathematic models of natural endocrine system, is first introduced here. Some typical AES algorithms and their applications are also briefly discussed. Finally, a few remarks and conclusions are made.

  4. Endovascular management for significant iatrogenic portal vein bleeding.

    Science.gov (United States)

    Kim, Jong Woo; Shin, Ji Hoon; Park, Jonathan K; Yoon, Hyun-Ki; Ko, Gi-Young; Gwon, Dong Il; Kim, Jin Hyoung; Sung, Kyu-Bo

    2017-11-01

    Background Despite conservative treatment, hemorrhage from an intrahepatic branch of the portal vein can cause hemodynamic instability requiring urgent intervention. Purpose To retrospectively report the outcomes of hemodynamically significant portal vein bleeding after endovascular management. Material and Methods During a period of 15 years, four patients (2 men, 2 women; median age, 70.5 years) underwent angiography and embolization for iatrogenic portal vein bleeding. Causes of hemorrhage, angiographic findings, endovascular treatment, and complications were reported. Results Portal vein bleeding occurred after percutaneous liver biopsy (n = 2), percutaneous radiofrequency ablation (n = 1), and percutaneous cholecystostomy (n = 1). The median time interval between angiography and percutaneous procedure was 5 h (range, 4-240 h). Common hepatic angiograms including indirect mesenteric portograms showed active portal vein bleeding into the peritoneal cavity with (n = 1) or without (n = 2) an arterioportal (AP) fistula, and portal vein pseudoaneurysm alone with an AP fistula (n = 1). Successful transcatheter arterial embolization (n = 2) or percutaneous transhepatic portal vein embolization (n = 2) was performed. Embolic materials were n-butyl cyanoacrylate alone (n = 2) or in combination with gelatin sponge particles and coils (n = 2). There were no major treatment-related complications or patient mortality within 30 days. Conclusion Patients with symptomatic or life-threatening portal vein bleeding following liver-penetrating procedures can successfully be managed with embolization.

  5. Conventional tomographic hilar anatomy emphasizing the pulmonary veins

    International Nuclear Information System (INIS)

    Genereux, G.P.

    1983-01-01

    The pulmonary hili are a frequent site of interpretive uncertainty because of thir complex anatomy. The right hilar shadow relates primarily to the ascending and descending pulmonary arteries and the right superior pulmonary vein, whereas the left hilar density accrues from the left pulmonary artery, left descending pulmonary artery, and left superior pulmonary vein. The right and left superoir pulmonary veins are intimately associated with and inseparable from the arteries. Knowledge of the course of these veins facilitates their identification on conventional tomograms. The right and left inferior pulmonary veins lie behind the lower hili and contribute only a small increment to the normal hilar density; the horizontal course of these vessels readily distinguishes them from the vertically oriented lower lobe arteries. Prominence of both the right and left superior and inferior veins may cause hilar pseudotumors. Conventional tomograms are most helpful in understanding plain radiographs. A multiview approach in anteroposterior, 55 0 posterior oblique, and lateral projections is recommended for a complete assessment. Computed tomography in transaxial sections adds further understanding of spatial relations in the hili, including the contributions of the pulmonary veins

  6. Artificial vision support system (AVS(2)) for improved prosthetic vision.

    Science.gov (United States)

    Fink, Wolfgang; Tarbell, Mark A

    2014-11-01

    State-of-the-art and upcoming camera-driven, implanted artificial vision systems provide only tens to hundreds of electrodes, affording only limited visual perception for blind subjects. Therefore, real time image processing is crucial to enhance and optimize this limited perception. Since tens or hundreds of pixels/electrodes allow only for a very crude approximation of the typically megapixel optical resolution of the external camera image feed, the preservation and enhancement of contrast differences and transitions, such as edges, are especially important compared to picture details such as object texture. An Artificial Vision Support System (AVS(2)) is devised that displays the captured video stream in a pixelation conforming to the dimension of the epi-retinal implant electrode array. AVS(2), using efficient image processing modules, modifies the captured video stream in real time, enhancing 'present but hidden' objects to overcome inadequacies or extremes in the camera imagery. As a result, visual prosthesis carriers may now be able to discern such objects in their 'field-of-view', thus enabling mobility in environments that would otherwise be too hazardous to navigate. The image processing modules can be engaged repeatedly in a user-defined order, which is a unique capability. AVS(2) is directly applicable to any artificial vision system that is based on an imaging modality (video, infrared, sound, ultrasound, microwave, radar, etc.) as the first step in the stimulation/processing cascade, such as: retinal implants (i.e. epi-retinal, sub-retinal, suprachoroidal), optic nerve implants, cortical implants, electric tongue stimulators, or tactile stimulators.

  7. Evaluation of the portal veins, hepatic veins and bile ducts using fat-suppressed segmented True FISP

    International Nuclear Information System (INIS)

    Ueda, Takashi; Uchikoshi, Masato; Imaoka, Izumi; Iwaya, Kazuo; Matsuo, Michimasa; Wada, Akihiko

    2005-01-01

    True FISP (fast imaging with steady-state free precession) is a fast imaging technique that provides high SNR (signal to noise ratio) and excellent delineation of parenchymal organs. The contrast of True FISP depends on the mixture of T 2 /T 1 . Vessels with slow flow are usually displayed as high signal intensity on True FISP images. The purpose of this study was to optimize fat-suppressed (FS) segmented True FISP imaging for portal veins, hepatic veins, and bile ducts. FS segmented True FISP images were applied to the phantoms of liver parenchyma, saline, and oil with various flip angles (every 10 degrees from 5-65 degrees) and k-space segmentations (3, 15, 25, 51, 75, 99). Five healthy volunteers were also examined to get optimized flip angle and k-space segmentation. The largest flip angle, 65 degrees, showed the best contrast between the liver parenchyma phantom, saline, and oil. The largest segmentations, 99, provided the best contrast between a liver parenchyma phantom and saline. However, the signal of the oil phantom exceeded that of the liver parenchyma phantom with 99 segmentations. As a result, the flip angle of 65 degrees and 75 segments is recommended to get the best contrast between the liver parenchyma phantom and saline, while suppressing the signal of oil. The volunteer studies also support the phantom studies and showed excellent anatomical delineation of portal veins, hepatic veins, and bile ducts when using these parameters. We conclude that True FISP is potentially suitable for the imaging of portal veins, hepatic veins, and bile ducts. The flip angle of 65 degrees with 75 segments is recommended to optimize FS segmented True FISP images. (author)

  8. Neutron spectrometry and dosimetry by means of Bonner spheres system and artificial neural networks applying robust design of artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Martinez B, M.R.; Ortiz R, J.M.; Vega C, H.R. [UAZ, Av. Ramon Lopez Velarde No. 801, 98000 Zacatecas (Mexico)

    2006-07-01

    An Artificial Neural Network has been designed, trained and tested to unfold neutron spectra and simultaneously to calculate equivalent doses. A set of 187 neutron spectra compiled by the International Atomic Energy Agency and 13 equivalent doses were used in the artificial neural network designed, trained and tested. In order to design the neural network was used the robust design of artificial neural networks methodology, which assures that the quality of the neural networks takes into account from the design stage. Unless previous works, here, for first time a group of neural networks were designed and trained to unfold 187 neutron spectra and at the same time to calculate 13 equivalent doses, starting from the count rates coming from the Bonner spheres system by using a systematic and experimental strategy. (Author)

  9. Neutron spectrometry and dosimetry by means of Bonner spheres system and artificial neural networks applying robust design of artificial neural networks

    International Nuclear Information System (INIS)

    Martinez B, M.R.; Ortiz R, J.M.; Vega C, H.R.

    2006-01-01

    An Artificial Neural Network has been designed, trained and tested to unfold neutron spectra and simultaneously to calculate equivalent doses. A set of 187 neutron spectra compiled by the International Atomic Energy Agency and 13 equivalent doses were used in the artificial neural network designed, trained and tested. In order to design the neural network was used the robust design of artificial neural networks methodology, which assures that the quality of the neural networks takes into account from the design stage. Unless previous works, here, for first time a group of neural networks were designed and trained to unfold 187 neutron spectra and at the same time to calculate 13 equivalent doses, starting from the count rates coming from the Bonner spheres system by using a systematic and experimental strategy. (Author)

  10. Artificial intelligence costs, benefits, risks for selected spacecraft ground system automation scenarios

    Science.gov (United States)

    Truszkowski, Walter F.; Silverman, Barry G.; Kahn, Martha; Hexmoor, Henry

    1988-01-01

    In response to a number of high-level strategy studies in the early 1980s, expert systems and artificial intelligence (AI/ES) efforts for spacecraft ground systems have proliferated in the past several years primarily as individual small to medium scale applications. It is useful to stop and assess the impact of this technology in view of lessons learned to date, and hopefully, to determine if the overall strategies of some of the earlier studies both are being followed and still seem relevant. To achieve that end four idealized ground system automation scenarios and their attendant AI architecture are postulated and benefits, risks, and lessons learned are examined and compared. These architectures encompass: (1) no AI (baseline), (2) standalone expert systems, (3) standardized, reusable knowledge base management systems (KBMS), and (4) a futuristic unattended automation scenario. The resulting artificial intelligence lessons learned, benefits, and risks for spacecraft ground system automation scenarios are described.

  11. Challenges facing the distribution of an artificial-intelligence-based system for nursing.

    Science.gov (United States)

    Evans, S

    1985-04-01

    The marketing and successful distribution of artificial-intelligence-based decision-support systems for nursing face special barriers and challenges. Issues that must be confronted arise particularly from the present culture of the nursing profession as well as the typical organizational structures in which nurses predominantly work. Generalizations in the literature based on the limited experience of physician-oriented artificial intelligence applications (predominantly in diagnosis and pharmacologic treatment) must be modified for applicability to other health professions.

  12. Generating and analyzing synthetic finger vein images

    OpenAIRE

    Hillerström, Fieke; Kumar, Ajay; Veldhuis, Raymond N.J.

    2014-01-01

    Abstract: The finger-vein biometric offers higher degree of security, personal privacy and strong anti-spoofing capabilities than most other biometric modalities employed today. Emerging privacy concerns with the database acquisition and lack of availability of large scale finger-vein database have posed challenges in exploring this technology for large scale applications. This paper details the first such attempt to synthesize finger-vein images and presents analysis of synthesized images fo...

  13. The sapheno femoral junction involvement in the treatment of varicose veins disease

    Directory of Open Access Journals (Sweden)

    Stefano Ricci

    2017-07-01

    Full Text Available Sapheno femoral junction (SFJ incompetence has been considered the most important cause of chronic venous insufficiency in a high percent of cases since the beginning of history varicose veins treatment. As a consequence SFJ dissection, ligation and section has been practiced all along the last century, generally associated to great saphenous vein stripping, with the porpoise of stopping the effect of hydrostatic pressure considered the origin of varicose veins. Recurrence prevalence at the site of SFJ, even in correctly performed dissection suggests that this attitude may not be the ideal one. Moreover, with the introduction of catheter-based systems of endovenous heating of the great saphenous vein with radiofrequency or endovenous laser ablation, it was shown that venous ablation could be achieved without high ligation of the SFJ. Also foam sclerotherapy demonstrated good results, even if less effective, always leaving the SFJ untouched. Following this trend several methods have been suggested that spare the SFJ, so that this site have lost its strategical importance. In this review history of the SFJ involvement in the varicose vein strategy is analyzed with particular attention to the new generation methods, technology assisted, launched on the market.

  14. Transjugular intrahepatic portosystemic shunt in a patient with cavernomatous portal vein occlusion

    International Nuclear Information System (INIS)

    Kawamata, Hiroshi; Kumazaki, Tatsuo; Kanazawa, Hidenori; Takahashi, Shuji; Tajima, Hiroyuki; Hayashi, Hiromitsu

    2000-01-01

    A 23-year-old woman with liver cirrhosis secondary to primary sclerosing cholangitis was referred to us for the treatment of recurrent bleeding from esophageal varices that had been refractory to endoscopic sclerotherapy. Her portal vein was occluded, associated with cavernous transformation. A transjugular intrahepatic portosystemic shunt (TIPS) was performed after a preprocedural three-dimensional computed tomographic angiography evaluation to determine feasibility. The portal vein system was recanalized and portal blood flow increased markedly after TIPS. Esophageal varices disappeared 3 weeks after TIPS. Re-bleeding and hepatic encephalopathy were absent for 3 years after the procedure. We conclude that with adequate preprocedural evaluation, TIPS can be performed safely even in patients with portal vein occlusion associated with cavernous transformation.

  15. Nonthrombotic artificial mass in right ventricle and pulmonary circulation as a sequence of vertebroplasty

    International Nuclear Information System (INIS)

    Monovska, T.; Kirova, G.; Bojinov, D.; Kichukov, K.

    2013-01-01

    Full text: Introduction: Percutaneous vertebroplasty for the treatment of the vertebral body fractures is considered to be relatively safe therapeutic procedure. Nevertheless there is a potential risk of spread of emboli from artificial material through external vertebral venous plexus. What you will learn: This is a 60 -year-old patient with primary diagnosis of multiple myeloma and conducted vertebroplasty due to the vertebral bodies fractures. Accompanying symptoms are: coughing up blood and pain in the right the chest with medication for micro thromboembolism form of Pulmonary thromboembolism (PTE). There are echocardiographic data on hospitalization for a formation in the right ventricle. Based on additionally performed CT study, a ‘foreign body’ - artificial material in right ventricle and subsegmentary branches of the pulmonary arteries as a complication of previous vertebroplasty has been recorded. Paravertebral venous vessels in the area of the thoracic section filled with cement have been noticed. Discussion: non-thrombotic embolism of artificial material prior vertebroplasty can be asymptomatic, or condition may be associated with life-threatening symptoms - compression of the spinal cord resulting in paraplegia, emboli in the cerebral vessels, right ventricle, kidney arteries. The frequency of the topical flowing of the used material is relatively high (80-90 %) to the para-vertebral vein (over 24%), with subsequent pulmonary emboli (4.6 to 6.8 %). The path of the embolization material dissemination is in the course of the para-vertebral veins, v. azygos and v. cafa inf., with the end goal pulmonary circulation. Conclusion: Follow-up of patients after the therapeutic vertebroplasty and integrated diagnostic approach with appropriate imaging methods allow timely diagnosis and treatment of this unusual form of non-thrombotic embolism

  16. TIPS Placement via Combined Transjugular and Transhepatic Approach for Cavernous Portal Vein Occlusion: Targeted Approach

    Directory of Open Access Journals (Sweden)

    Natanel Jourabchi

    2013-01-01

    Full Text Available Purpose. We report a novel technique which aided recanalization of an occluded portal vein for transjugular intrahepatic portosystemic shunt (TIPS creation in a patient with symptomatic portal vein thrombosis with cavernous transformation. Some have previously considered cavernous transformation a contraindication to TIPS. Case Presentation. 62-year-old man with chronic pancreatitis, portal vein thrombosis, portal hypertension and recurrent variceal bleeding presents with melena and hematemesis. The patient was severely anemic, hemodynamically unstable, and required emergent portal decompression. Attempts to recanalize the main portal vein using traditional transjugular access were unsuccessful. After percutaneous transhepatic right portal vein access and navigation of a wire through the occluded main portal vein, an angioplasty balloon was inflated at the desired site of shunt takeoff. The balloon was targeted and punctured from the transjugular approach, and a wire was passed into the portal system. TIPS placement then proceeded routinely. Conclusion. Although occlusion of the portal vein increases difficulty of performing TIPS, it should not be considered an absolute contraindication. We have described a method for recanalizing an occluded portal vein using a combined transhepatic and transjugular approach for TIPS. This approach may be useful to relieve portal hypertension in patients who fail endoscopic and/or surgical therapies.

  17. Admittance Control for Robot Assisted Retinal Vein Micro-Cannulation under Human-Robot Collaborative Mode.

    Science.gov (United States)

    Zhang, He; Gonenc, Berk; Iordachita, Iulian

    2017-10-01

    Retinal vein occlusion is one of the most common retinovascular diseases. Retinal vein cannulation is a potentially effective treatment method for this condition that currently lies, however, at the limits of human capabilities. In this work, the aim is to use robotic systems and advanced instrumentation to alleviate these challenges, and assist the procedure via a human-robot collaborative mode based on our earlier work on the Steady-Hand Eye Robot and force-sensing instruments. An admittance control method is employed to stabilize the cannula relative to the vein and maintain it inside the lumen during the injection process. A pre-stress strategy is used to prevent the tip of microneedle from getting out of vein in in prolonged infusions, and the performance is verified through simulations.

  18. Artificial Intelligence in the service of system administrators

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called “self objectives” supposed to lead to “autonomic computing”. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way  Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with a "object oriented paradigm" architecture should increase a lot our learning speed, and highlight relations between probl...

  19. Artificial intelligence tools decision support systems in condition monitoring and diagnosis

    CERN Document Server

    Galar Pascual, Diego

    2015-01-01

    Artificial Intelligence Tools: Decision Support Systems in Condition Monitoring and Diagnosis discusses various white- and black-box approaches to fault diagnosis in condition monitoring (CM). This indispensable resource: Addresses nearest-neighbor-based, clustering-based, statistical, and information theory-based techniques Considers the merits of each technique as well as the issues associated with real-life application Covers classification methods, from neural networks to Bayesian and support vector machines Proposes fuzzy logic to explain the uncertainties associated with diagnostic processes Provides data sets, sample signals, and MATLAB® code for algorithm testing Artificial Intelligence Tools: Decision Support Systems in Condition Monitoring and Diagnosis delivers a thorough evaluation of the latest AI tools for CM, describing the most common fault diagnosis techniques used and the data acquired when these techniques are applied.

  20. Artificial senses for characterization of food quality

    Institute of Scientific and Technical Information of China (English)

    HUANG Yan-bo; LAN Yu-bin; R.E. Lacey

    2004-01-01

    Food quality is of primary concern in the food industry and to the consumer. Systems that mimic human senses have been developed and applied to the characterization of food quality. The five primary senses are: vision, hearing, smell, taste and touch.In the characterization of food quality, people assess the samples sensorially and differentiate "good" from "bad" on a continuum.However, the human sensory system is subjective, with mental and physical inconsistencies, and needs time to work. Artificial senses such as machine vision, the electronic ear, electronic nose, electronic tongue, artificial mouth and even artificial the head have been developed that mimic the human senses. These artificial senses are coordinated individually or collectively by a pattern recognition technique, typically artificial neural networks, which have been developed based on studies of the mechanism of the human brain. Such a structure has been used to formulate methods for rapid characterization of food quality. This research presents and discusses individual artificial sensing systems. With the concept of multi-sensor data fusion these sensor systems can work collectively in some way. Two such fused systems, artificial mouth and artificial head, are described and discussed. It indicates that each of the individual systems has their own artificially sensing ability to differentiate food samples. It further indicates that with a more complete mimic of human intelligence the fused systems are more powerful than the individual systems in differentiation of food samples.

  1. Tumor and liver drug uptake following hepatic artery and portal vein infusion

    International Nuclear Information System (INIS)

    Sigurdson, E.R.; Ridge, J.A.; Kemeny, N.; Daly, J.M.

    1987-01-01

    Anatomic dye injection studies of the blood supply of colorectal hepatic metastases suggest that tumors are supplied predominantly by the hepatic artery. Using 13 N amino acids with dynamic gamma camera imaging in patients with colorectal hepatic metastases, it has been shown that hepatic artery infusion results in a significantly greater nutrient delivery to tumor compared with portal vein infusion. However, direct measurements of drug levels in tumor following hepatic artery and portal vein infusion in humans have not previously been reported. Patients with metastatic colorectal cancer confined to the liver received fluorodeoxyuridine (FUdR) through the hepatic artery or through the portal vein. All patients had previously failed systemic chemotherapy. Five patients with hepatic artery catheters were matched (by age, serum lactic dehydrogenase levels, percent hepatic replacement, and tumor size) with five patients with portal vein catheters. At operation, 3 H-FUdR (1 microCi/kg) and /sup 99m/Tc-macroaggregated albumin (MAA) (6 mCi) were injected into the hepatic artery or portal vein. Liver and tumor biopsies were obtained two and five minutes later. 3 H and /sup 99m/Tc were measured per gram tissue by scintillation and gamma counting. The mean liver levels following hepatic artery infusion (23.9 +/- 11.4 nmol/g) and portal vein infusion (18.4 +/- 14.5 nmol/g) did not differ. However, the mean tumor FUdR level following hepatic artery infusion was 12.4 +/- 12.2 nmol/g, compared with a mean tumor FUdR level following portal vein infusion of 0.8 +/- 0.7 nmol/g (P less than .01). This low level of tumor drug uptake after portal vein infusion of FUdR predicts minimal tumor response to treatment via this route. Thus, regional chemotherapy for established colorectal hepatic metastases should be administered through the hepatic artery

  2. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    International Nuclear Information System (INIS)

    Currarino, G.; Stannard, M.W.; Texas Univ., Dallas, TX; Kolni, H.

    1991-01-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.)

  3. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, G.; Stannard, M.W. (Children' s Medical Center, Dallas, TX (United States). Dept. of Radiology Texas Univ., Dallas, TX (United States). Southwestern Medical Center); Kolni, H. (Methodist Hospital, Dallas, TX (United States). Dept. of Pediatrics)

    1991-05-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.).

  4. Artificial intelligence and dynamic systems for geophysical applications

    CERN Document Server

    Gvishiani, Alexei

    2002-01-01

    The book presents new clustering schemes, dynamical systems and pattern recognition algorithms in geophysical, geodynamical and natural hazard applications. The original mathematical technique is based on both classical and fuzzy sets models. Geophysical and natural hazard applications are mostly original. However, the artificial intelligence technique described in the book can be applied far beyond the limits of Earth science applications. The book is intended for research scientists, tutors, graduate students, scientists in geophysics and engineers

  5. Episodic vein formation in Gale crater, Mars: evidence for an extended history of liquid water

    Science.gov (United States)

    Kronyak, R. E.; Fedo, C.; Banham, S.; Edgett, K. S.; Newsom, H. E.; Nachon, M.; Kah, L. C.

    2017-12-01

    The sedimentary rock record of Gale crater is consistent with deposition in an ancient lake basin. These strata represent aqueous and potentially habitable past conditions that existed over a relatively small part of Mars' geologic history. Post-depositional fluid migration is recorded by the presence of veins, which have been prevalent features throughout Curiosity's mission. These veins record later episodes of fluid flow and represent an extended history of liquid water stability, and perhaps habitability. White Ca-sulfate veins are observed in the Bradbury (Yellowknife Bay), Mount Sharp (Murray formation), and Siccar Point (Stimson formation) groups across a range of lithologies. At Yellowknife Bay and in the Stimson, Ca-sulfate veins characteristically exhibit mm-scale thicknesses. In the Pahrump Hills (PH) area, 62% of measured veins in the Murray formation are material occurs along the interface between wall rock and Ca-sulfate and is interpreted as a precursor vein fill. Gray veins at PH are more erosionally resistant relative to Ca-sulfate and average 1 mm in width. Additionally, gray veins exhibit elevated Mg and depleted Ca, distinguishing them compositionally from Ca-sulfate veins. Veins continue locally throughout the stratigraphic section. The lowermost Stimson sandstones at the Missoula outcrop contain white clasts and elevated Ca-sulfate, suggesting the formation of Murray veins prior to the deposition of the Stimson formation. Near the Old Soaker outcrop, bedding-parallel sulfate may represent syndepositional gypsum precipitation. In the context of time, the multiple vein systems identified in the Gale crater sedimentary fill shed light on the sequence and evolution of fluids responsible for their deposition. It is envisioned that sulfates first precipitated contemporaneously with the deposition of the Murray formation, followed by burial, lithification, and fracturing to form the earliest gray and sulfate veins. The Murray was then exhumed and

  6. [Artificial organs].

    Science.gov (United States)

    Raguin, Thibaut; Dupret-Bories, Agnès; Debry, Christian

    2017-01-01

    Research has been fighting against organ failure and shortage of donations by supplying artificial organs for many years. With the raise of new technologies, tissue engineering and regenerative medicine, many organs can benefit of an artificial equivalent: thanks to retinal implants some blind people can visualize stimuli, an artificial heart can be proposed in case of cardiac failure while awaiting for a heart transplant, artificial larynx enables laryngectomy patients to an almost normal life, while the diabetic can get a glycemic self-regulation controlled by smartphones with an artificial device. Dialysis devices become portable, as well as the oxygenation systems for terminal respiratory failure. Bright prospects are being explored or might emerge in a near future. However, the retrospective assessment of putative side effects is not yet sufficient. Finally, the cost of these new devices is significant even if the advent of three dimensional printers may reduce it. © 2017 médecine/sciences – Inserm.

  7. Simulation of Artificial Intelligence for Automotive Air-conditioning System

    Institute of Scientific and Technical Information of China (English)

    YUAN Xiao-mei; CHEN You-hua; CHEN Zhi-jiu

    2002-01-01

    The artificial intelligence is applied to the simulation of the automotive air-conditioning system ( AACS )According to the system's characteristics a model of AACS, based on neural network, is developed. Different control methods of AACS are discussed through simulation based on this model. The result shows that the neural- fuzzy control is the best one compared with the on-off control and conventional fuzzy control method.It can make the compartment's temperature descend rapidly to the designed temperature and the fluctuation is small.

  8. Patterning of leaf vein networks by convergent auxin transport pathways.

    Science.gov (United States)

    Sawchuk, Megan G; Edgar, Alexander; Scarpella, Enrico

    2013-01-01

    The formation of leaf vein patterns has fascinated biologists for centuries. Transport of the plant signal auxin has long been implicated in vein patterning, but molecular details have remained unclear. Varied evidence suggests a central role for the plasma-membrane (PM)-localized PIN-FORMED1 (PIN1) intercellular auxin transporter of Arabidopsis thaliana in auxin-transport-dependent vein patterning. However, in contrast to the severe vein-pattern defects induced by auxin transport inhibitors, pin1 mutant leaves have only mild vein-pattern defects. These defects have been interpreted as evidence of redundancy between PIN1 and the other four PM-localized PIN proteins in vein patterning, redundancy that underlies many developmental processes. By contrast, we show here that vein patterning in the Arabidopsis leaf is controlled by two distinct and convergent auxin-transport pathways: intercellular auxin transport mediated by PM-localized PIN1 and intracellular auxin transport mediated by the evolutionarily older, endoplasmic-reticulum-localized PIN6, PIN8, and PIN5. PIN6 and PIN8 are expressed, as PIN1 and PIN5, at sites of vein formation. pin6 synthetically enhances pin1 vein-pattern defects, and pin8 quantitatively enhances pin1pin6 vein-pattern defects. Function of PIN6 is necessary, redundantly with that of PIN8, and sufficient to control auxin response levels, PIN1 expression, and vein network formation; and the vein pattern defects induced by ectopic PIN6 expression are mimicked by ectopic PIN8 expression. Finally, vein patterning functions of PIN6 and PIN8 are antagonized by PIN5 function. Our data define a new level of control of vein patterning, one with repercussions on other patterning processes in the plant, and suggest a mechanism to select cell files specialized for vascular function that predates evolution of PM-localized PIN proteins.

  9. Patterning of leaf vein networks by convergent auxin transport pathways.

    Directory of Open Access Journals (Sweden)

    Megan G Sawchuk

    Full Text Available The formation of leaf vein patterns has fascinated biologists for centuries. Transport of the plant signal auxin has long been implicated in vein patterning, but molecular details have remained unclear. Varied evidence suggests a central role for the plasma-membrane (PM-localized PIN-FORMED1 (PIN1 intercellular auxin transporter of Arabidopsis thaliana in auxin-transport-dependent vein patterning. However, in contrast to the severe vein-pattern defects induced by auxin transport inhibitors, pin1 mutant leaves have only mild vein-pattern defects. These defects have been interpreted as evidence of redundancy between PIN1 and the other four PM-localized PIN proteins in vein patterning, redundancy that underlies many developmental processes. By contrast, we show here that vein patterning in the Arabidopsis leaf is controlled by two distinct and convergent auxin-transport pathways: intercellular auxin transport mediated by PM-localized PIN1 and intracellular auxin transport mediated by the evolutionarily older, endoplasmic-reticulum-localized PIN6, PIN8, and PIN5. PIN6 and PIN8 are expressed, as PIN1 and PIN5, at sites of vein formation. pin6 synthetically enhances pin1 vein-pattern defects, and pin8 quantitatively enhances pin1pin6 vein-pattern defects. Function of PIN6 is necessary, redundantly with that of PIN8, and sufficient to control auxin response levels, PIN1 expression, and vein network formation; and the vein pattern defects induced by ectopic PIN6 expression are mimicked by ectopic PIN8 expression. Finally, vein patterning functions of PIN6 and PIN8 are antagonized by PIN5 function. Our data define a new level of control of vein patterning, one with repercussions on other patterning processes in the plant, and suggest a mechanism to select cell files specialized for vascular function that predates evolution of PM-localized PIN proteins.

  10. Quantification of deep medullary veins at 7 T brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kuijf, Hugo J.; Viergever, Max A.; Vincken, Koen L. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Bouvy, Willem H.; Razoux Schultz, Tom B.; Biessels, Geert Jan [University Medical Center Utrecht, Department of Neurology, Brain Center Rudolf Magnus, Utrecht (Netherlands); Zwanenburg, Jaco J.M. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands)

    2016-10-15

    Deep medullary veins support the venous drainage of the brain and may display abnormalities in the context of different cerebrovascular diseases. We present and evaluate a method to automatically detect and quantify deep medullary veins at 7 T. Five participants were scanned twice, to assess the robustness and reproducibility of manual and automated vein detection. Additionally, the method was evaluated on 24 participants to demonstrate its application. Deep medullary veins were assessed within an automatically created region-of-interest around the lateral ventricles, defined such that all veins must intersect it. A combination of vesselness, tubular tracking, and hysteresis thresholding located individual veins, which were quantified by counting and computing (3-D) density maps. Visual assessment was time-consuming (2 h/scan), with an intra-/inter-observer agreement on absolute vein count of ICC = 0.76 and 0.60, respectively. The automated vein detection showed excellent inter-scan reproducibility before (ICC = 0.79) and after (ICC = 0.88) visually censoring false positives. It had a positive predictive value of 71.6 %. Imaging at 7 T allows visualization and quantification of deep medullary veins. The presented method offers fast and reliable automated assessment of deep medullary veins. (orig.)

  11. Preoperative mapping of the saphenous vein

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Sillesen, H; Nielsen, Tina G

    1996-01-01

    A series of 124 patients had their greater saphenous vein assessed with duplex ultrasound scanning prior to planned infrainguinal bypass procedures. 33 (27%) bypass procedures thrombosed within the first year. A naturally occurring optimal vein diameter was discovered: 5.0-6.5 mm at mid-thigh lev...

  12. Anatomical variations of the iliolumbar vein with application to the anterior retroperitoneal approach to the lumbar spine: a cadaver study.

    Science.gov (United States)

    Unruh, Kenneth P; Camp, Christopher L; Zietlow, Scott P; Huddleston, Paul M

    2008-10-01

    Objectives of this study include identification of lumbosacral venous variations, designation of a critical area of dissection for surgical exposure, and comparison between both male/female and right/left-sided anatomy. Attempts were made to provide anatomic nomenclature that accurately describes these structures. Thirty-eight iliolumbar venous systems in 20 cadavers (11 females/9 males) were dissected. Each system was identified as one of three patterns of variation: common venous trunk (combining ascending lumbar and iliolumbar venous systems) with distal veins, common venous trunk without distal veins, and venous systems without a common venous trunk. Dimensions including distances to the inferior vena cava (IVC) confluence, the obturator nerve, and the lumbosacral trunk, and venous stem length were obtained to aid surgical dissection. Differences between males and females and those between right and left sides were compared. Anterior lumbosacral venous variations could be organized into three groups. A Type 1 venous system (common venous trunk with distal veins) was most common (53% of systems). The anatomical name "lateral lumbosacral veins" adequately describes the anatomical location of these veins and does not assume a direction of venous flow or the lack of individual distal veins. A critical area bordered by the obturator nerve anteriorly, the psoas muscle laterally, the spinal column medially, and sacrum posteriorly within 8.2 cm of the IVC confluence should be defined to adequately dissect the lateral lumbosacral veins. Differences in male and female lateral lumbosacral venous anatomy do not alter surgeon's approach to the anterior lumbar spine. (c) 2008 Wiley-Liss, Inc.

  13. Recanalization after acute deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Gustavo Mucoucah Sampaio Brandao

    2013-12-01

    Full Text Available The process of recanalization of the veins of the lower limbs after an episode of acute deep venous thrombosis is part of the natural evolution of the remodeling of the venous thrombus in patients on anticoagulation with heparin and vitamin K inhibitors. This remodeling involves the complex process of adhesion of thrombus to the wall of the vein, the inflammatory response of the vessel wall leading to organization and subsequent contraction of the thrombus, neovascularization and spontaneous lysis of areas within the thrombus. The occurrence of spontaneous arterial flow in recanalized thrombosed veins has been described as secondary to neovascularization and is characterized by the development of flow patterns characteristic of arteriovenous fistulae that can be identified by color duplex scanning. In this review, we discuss some controversial aspects of the natural history of deep vein thrombosis to provide a better understanding of its course and its impact on venous disease.

  14. The application of artificial intelligence chemistry diagnostic system to nuclear power plants

    International Nuclear Information System (INIS)

    Chen Meizhen

    1996-01-01

    By processing water chemistry data to diagnose sensor and equipment malfunctions in realtime, artificial intelligence chemistry diagnostic system helps to reduce the plant downtime due to steam generator tubing failures and other accidents. A typical processing system of water chemistry data is presented

  15. Renal vein doppler sonography in rabbits with acute ureteral obstruction: usefulness of impedance index of renal vein

    International Nuclear Information System (INIS)

    Sohn, Kyung Myung; Chung, Su Kyo; Lee, Sung Yong

    2004-01-01

    To evaluate the usefulness of the impedance index of the renal vein for the diagnosis of acute obstructive uropathy in rabbits. Ligation of the left ureter was done in 12 rabbits. Doppler sonography of the interlobar veins in both kidneys was checked before and 30 minutes, 1, 3, 6, 9 and 24 hours after ureteral ligation. The venous impedance index [(peak flow signal-least flow signal)/peak flow signal] was compared between the obstructed and non-obstructed kidneys for all periods. The change in the impedance index after ureteral ligation was also compared between the obstructed and non-obstructed kidneys. A decrease in the impedance index of the intrarenal vein was observed starting from 30 mins atter ureteral ligation, and the index remained low up to 24 hours after ureteral ligation. The obstructed kidneys had a significantly lower impedance index than the contralateral kidneys for all six of the postligation measurements (p< 0.05). There were significant differences in the change of impedance index after ureteral ligation between the obstructed and non-obstructed kidneys (p< 0.05). The impedance index of the intrarenal vein was significantly decreased in the obstructed kidneys. The measurement of the impedance index of the intrarenal vein using Doppler sonography could provide a useful method of diagnosing obstructive uropathy

  16. Design of biometrics identification system on palm vein using infrared light

    Science.gov (United States)

    Syafiq, Muhammad; Nasution, Aulia M. T.

    2016-11-01

    Image obtained by the LED with wavelength 740nm and 810nm showed that the contrast gradient of vein pattern is low and palm pattern still exist. It means that 740nm and 810nm are less suitable for the detection of blood vessels in the palm of the hand. At a wavelength of 940nm, the pattern is clearly visible, and the pattern of the palms is mostly gone. Furthermore, the pre-processing performed using smoothing process which include Gaussian filter and median filter and contrast stretching. Image segmentation is done by getting the ROI area that would be obtained its information. The identification process of image features obtained by using MSE (Mean Suare Error) method ,LBP (Local Binary Pattern). Furthermore, we will use a database consists of 5 different palm vein pattern which will be used for testing the tool in the identification process. All the process above are done using Raspberry Pi device. The Obtained MSE parameter is 0.025 and LBP features score are less than 10-3 for image to be matched.

  17. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    OpenAIRE

    Madhusudhan, KS; Agrawal, Nikhil; Srivastava, Deep N; Pal, Sujoy; Gupta, Arun K

    2013-01-01

    Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, su...

  18. Animal Model of Acute Deep Vein Thrombosis

    International Nuclear Information System (INIS)

    Roy, Sumit; Laerum, Frode; Brosstad, Frank; Kvernebo, Knut; Sakariassen, Kjell S.

    1998-01-01

    Purpose: To develop an animal model of acute deep vein thrombosis (DVT). Methods: In part I of the study nine juvenile domestic pigs were used. Each external iliac vein was transluminally occluded with a balloon catheter. Thrombin was infused through a microcatheter in one leg according to one of the following protocols: (1) intraarterial (IA): 1250 U at 25 U/min in the common femoral artery (n= 3); (2) intravenous (IV): 5000 U in the popliteal vein at 500 U/min (n= 3), or at 100 U/min (n= 3). Saline was administered in the opposite leg. After the animals were killed, the mass of thrombus in the iliofemoral veins was measured. The pudendoepiploic (PEV), profunda femoris (PF), and popliteal veins (PV) were examined. Thrombosis in the tributaries of the superficial femoral vein (SFVt) was graded according to a three-point scale (0, +, ++). In part II of the study IV administration was further investigated in nine pigs using the following three regimens with 1000 U at 25 U/min serving as the control: (1) 1000 U at 100 U/min, (2) 250 U at 25 U/min, (3) 250 U at 6.25 U/min. Results: All animals survived. In part I median thrombus mass in the test limbs was 1.40 g as compared with 0.25 g in the controls (p= 0.01). PEV, PFV and PV were thrombosed in all limbs infused with thrombin. IV infusion was more effective in inducing thrombosis in both the parent veins (mass 1.32-1.78 g) and SVFt (++ in 4 of 6 legs), as compared with IA infusion (mass 0.0-1.16 g; SFVt ++ in 1 of 3 legs). In part II thrombus mass in axial veins ranged from 1.23 to 2.86 g, and showed no relationship with the dose of thrombin or the rate of infusion. Tributary thrombosis was less extensive with 250 U at 25 U/min than with the other regimens. Conclusion: Slow distal intravenous thrombin infusion in the hind legs of pigs combined with proximal venous occlusion induces thrombosis in the leg veins that closely resembles clinical DVT in distribution

  19. Combination of artificial intelligence and procedural language programs in a computer application system supporting nuclear reactor operations

    International Nuclear Information System (INIS)

    Town, G.G.; Stratton, R.C.

    1985-01-01

    A computer application system is described which provides nuclear reactor power plant operators with an improved decision support system. This system combines traditional computer applications such as graphics display with artificial intelligence methodologies such as reasoning and diagnosis so as to improve plant operability. This paper discusses the issues, and a solution, involved with the system integration of applications developed using traditional and artificial intelligence languages

  20. An open and configurable embedded system for EMG pattern recognition implementation for artificial arms.

    Science.gov (United States)

    Jun Liu; Fan Zhang; Huang, He Helen

    2014-01-01

    Pattern recognition (PR) based on electromyographic (EMG) signals has been developed for multifunctional artificial arms for decades. However, assessment of EMG PR control for daily prosthesis use is still limited. One of the major barriers is the lack of a portable and configurable embedded system to implement the EMG PR control. This paper aimed to design an open and configurable embedded system for EMG PR implementation so that researchers can easily modify and optimize the control algorithms upon our designed platform and test the EMG PR control outside of the lab environments. The open platform was built on an open source embedded Linux Operating System running a high-performance Gumstix board. Both the hardware and software system framework were openly designed. The system was highly flexible in terms of number of inputs/outputs and calibration interfaces used. Such flexibility enabled easy integration of our embedded system with different types of commercialized or prototypic artificial arms. Thus far, our system was portable for take-home use. Additionally, compared with previously reported embedded systems for EMG PR implementation, our system demonstrated improved processing efficiency and high system precision. Our long-term goals are (1) to develop a wearable and practical EMG PR-based control for multifunctional artificial arms, and (2) to quantify the benefits of EMG PR-based control over conventional myoelectric prosthesis control in a home setting.

  1. Artificial Intelligence, Expert Systems, Natural Language Interfaces, Knowledge Engineering and the Librarian.

    Science.gov (United States)

    Davies, Jim

    This paper begins by examining concepts of artificial intelligence (AI) and discusses various definitions of the concept that have been suggested in the literature. The nesting relationship of expert systems within the broader framework of AI is described, and expert systems are characterized as knowledge-based systems (KBS) which attempt to solve…

  2. Artificial heart system thermal insulation component development

    International Nuclear Information System (INIS)

    Svedberg, R.C.; Buckman, R.W. Jr.

    1975-01-01

    A concentric cup vacuum multifoil insulation system has been selected by virtue of its size, weight, and thermal performance to insulate the hot radioisotope portion of the thermal converter of an artificial implantable heart system. A factor of 2 improvement in thermal performance, based on the heat loss per number of foil layers (minimum system weight and volume) has been realized over conventional spiral wrapped multifoil vacuum insulation. This improvement is the result of the concentric cup construction to maintain a uniform interfoil spacing and the elimination of corner heat losses. Based on external insulation system dimensions (surface area in contact with host body), heat losses of 0.019 W/ cm 2 at 1140 0 K (1600 0 F) and 0.006 W/cm 2 at 920 0 K (1200 0 F) have been achieved. Factors which influence thermal performance of the nickel foil concentric cup insulation system include the number of cups, configuration and method of application of zirconia (ZrO 2 ) spacer material, system pressure, emittance of the cups, and operating temperature

  3. A Case Study of Deep Vein Thrombosis of the Right Internal Jugular Vein in a Healthy 21-Year-Old Male

    Directory of Open Access Journals (Sweden)

    Javier Corral

    2016-01-01

    Full Text Available We are reporting a case of a healthy 21-year-old male, with no significant past medical history, who was found to have an incidental nonocclusive deep vein thrombosis in the right internal jugular vein detected on a head MRI previously ordered for work-up of headaches. A follow-up upper extremity venous Doppler ultrasound confirmed the presence of a partially occlusive deep vein thrombosis in the right jugular vein. The case presented is unique for the reason that the patient is young and has no prior risk factor, personal or familial, for venous thrombosis except for associated polycythemia on clinical presentation.

  4. Congenital absence of the portal vein presenting as pulmonary hypertension

    International Nuclear Information System (INIS)

    Jun, Sur Young; Lee, Whal; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One; Yeon, Kyung Mo

    2007-01-01

    Congenital absence of the portal vein (CAPV) is a rare malformation in which intestinal and splenic venous flow bypasses the liver and drains directly into the systemic circulation via a congenital portosystemic shunt. We describe two cases of CAPV presenting as pulmonary hypertension that were initially suspected as primary pulmonary hypertension. However, subsequent ultrasonography and CT detected the absence of a portal vein and the presence of a portosystemic shunt. Pulmonary hypertension is a recognized complication of liver disease and portal hypertension. However, these two cases illustrate that CAPV may result in pulmonary hypertension without liver disease or portal hypertension

  5. Congenital absence of the portal vein presenting as pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Sur Young; Lee, Whal; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One; Yeon, Kyung Mo [Seoul National University Hospital, Seoul (Korea, Republic of)

    2007-11-15

    Congenital absence of the portal vein (CAPV) is a rare malformation in which intestinal and splenic venous flow bypasses the liver and drains directly into the systemic circulation via a congenital portosystemic shunt. We describe two cases of CAPV presenting as pulmonary hypertension that were initially suspected as primary pulmonary hypertension. However, subsequent ultrasonography and CT detected the absence of a portal vein and the presence of a portosystemic shunt. Pulmonary hypertension is a recognized complication of liver disease and portal hypertension. However, these two cases illustrate that CAPV may result in pulmonary hypertension without liver disease or portal hypertension.

  6. Artificial cognition architectures

    CERN Document Server

    Crowder, James A; Friess, Shelli A

    2013-01-01

    The goal of this book is to establish the foundation, principles, theory, and concepts that are the backbone of real, autonomous Artificial Intelligence. Presented here are some basic human intelligence concepts framed for Artificial Intelligence systems. These include concepts like Metacognition and Metamemory, along with architectural constructs for Artificial Intelligence versions of human brain functions like the prefrontal cortex. Also presented are possible hardware and software architectures that lend themselves to learning, reasoning, and self-evolution

  7. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  8. Admittance Control for Robot Assisted Retinal Vein Micro-Cannulation under Human-Robot Collaborative Mode

    Science.gov (United States)

    Gonenc, Berk; Iordachita, Iulian

    2017-01-01

    Retinal vein occlusion is one of the most common retinovascular diseases. Retinal vein cannulation is a potentially effective treatment method for this condition that currently lies, however, at the limits of human capabilities. In this work, the aim is to use robotic systems and advanced instrumentation to alleviate these challenges, and assist the procedure via a human-robot collaborative mode based on our earlier work on the Steady-Hand Eye Robot and force-sensing instruments. An admittance control method is employed to stabilize the cannula relative to the vein and maintain it inside the lumen during the injection process. A pre-stress strategy is used to prevent the tip of microneedle from getting out of vein in in prolonged infusions, and the performance is verified through simulations. PMID:29607442

  9. PRONET: Basic concepts of a system of Artificial Intelligence

    Directory of Open Access Journals (Sweden)

    S. Lasai

    1999-12-01

    Full Text Available In the work are expounded the principles and basic elements of a system of artificial intelligence. Knowledge representation develops according to the method settled for processing. A thing, a phenomenon can be determined or established by more modules subject to their state as well as the links and relations between them. The system creates a set of blocks (modules for which the concurrent work is pre- established. The volume of knowledge can be also increased without increasing the number of blocks.

  10. Computed tomographic evaluation of the portal vein in the hepatomas

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1986-10-15

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  11. Computed tomographic evaluation of the portal vein in the hepatomas

    International Nuclear Information System (INIS)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam

    1986-01-01

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  12. A Review of Intelligent Driving Style Analysis Systems and Related Artificial Intelligence Algorithms.

    Science.gov (United States)

    Meiring, Gys Albertus Marthinus; Myburgh, Hermanus Carel

    2015-12-04

    In this paper the various driving style analysis solutions are investigated. An in-depth investigation is performed to identify the relevant machine learning and artificial intelligence algorithms utilised in current driver behaviour and driving style analysis systems. This review therefore serves as a trove of information, and will inform the specialist and the student regarding the current state of the art in driver style analysis systems, the application of these systems and the underlying artificial intelligence algorithms applied to these applications. The aim of the investigation is to evaluate the possibilities for unique driver identification utilizing the approaches identified in other driver behaviour studies. It was found that Fuzzy Logic inference systems, Hidden Markov Models and Support Vector Machines consist of promising capabilities to address unique driver identification algorithms if model complexity can be reduced.

  13. Artificial Intelligence and Expert Systems Research and Their Possible Impact on Information Science.

    Science.gov (United States)

    Borko, Harold

    1985-01-01

    Defines artificial intelligence (AI) and expert systems; describes library applications utilizing AI to automate creation of document representations, request formulations, and design and modify search strategies for information retrieval systems; discusses expert system development for information services; and reviews impact of these…

  14. A Modified Technique of Basilic Vein Transposition for Haemodialysis

    International Nuclear Information System (INIS)

    Chaudhary, F. A.; Parvez, Z.

    2014-01-01

    Objective: To modify the technique of basilic vein transposition for vascular accesss for haemodialysis aiming at better maturation rate, longer survival of fistula and lesser complications. Study Design: Case series. Place and Duration of Study: Shaikh Zayed Hospital and Omer Hospital, Lahore, from February 2008 to July 2011. Methodology: Patients referred for basilic vein transposition for haemodialysis vascular access were prospectively enrolled. The surgical technique included small tracking incisions, an extra 3 - 4 cm of vein length harvesting to avoid tension in the vein in its new course, an oval arteriotomy and a smooth curved pathway, away from vein harvesting incision to avoid entrapment of vein in the scar. Maturation rate, fistula survival and other complications were noted. Results: There was no immediate failure in 51 patients. The complications during follow-up period were infection and thrombosis, bleeding and non-development of basilic vein in 2 patients each; and false aneurysm formation in one. Four patients died during follow-up period. The maturation time was 4.9 A +- 1.1 weeks. The early patency rate was 92.2%, same at 6 months and 90.7% at 12 months. Conclusion: Arteriovenous fistula constructed with modified technique of basilic vein transposition is an acceptable and valid option of vascular access for haemodialysis. (author)

  15. The magmatic model for the origin of Archean Au-quartz vein ore systems: an assessment of the evidence

    International Nuclear Information System (INIS)

    Spooner, E.T.C.

    1991-01-01

    The magmatic model for the origin of Archean Au-quartz vein ore systems suggests that Au was derived by partition between silicate (± sulphide) melts of certain compositions and H 2 O-CO 2 -NaCl magmatic fluids. Supporting evidence includes partial/structural geological relationships, timing relationships, H and C isotope geochemistry, probable primary Au enrichment in the Lamaque stocks, and fluid inclusion volatile geochemistry. Evidence is currently negative with respect to various within- and sub-greenstone belt metamorphic/deep crustal fluid models for primary Au mineralization; however a U-Pb age for vein stage 3 sphene from the Camflo deposit, Quebec which is ∼ 55-60 Ma younger than the host stock at 2685-2680 Ma indicates dissolution/reprecipitation of Au by late, (?) upper crustal saline fluids. Evidence is accumulating that epithermal-meso thermal Au-Ag mineralization in island arc and cordilleran settings may also have been magmatically derived ± high level fluid mixing from calc-alkaline, shoshonitic and other igneous compositions. (author)

  16. A case of double inferior vena cava with renal, ovarian and iliac vein variation.

    Science.gov (United States)

    Ito, Taro; Ikeda, Yayoi

    2018-01-01

    We encountered a rare case of an anatomic variant of inferior vena cava (IVC) duplication with renal, ovarian and iliac vein variation in an 81-year-old Japanese female cadaver during a student dissection course of anatomy at Aichi Gakuin University School of Dentistry. The two IVCs ran upwards bilaterally to the abdominal aorta. The left IVC joined with the left renal vein (RV) to form a common trunk that crossed anterior to the aorta and ended at the right IVC. We detected a vein [interiliac vein (IiV)] connecting the two IVCs at the level of the aortic bifurcation. The IiV was formed by the union of two tributaries from the left IVC and a tributary from the left internal iliac vein (IIV) and ran obliquely upwards from left to right. Two right ovarian veins, arising separately from the ipsilateral pampiniform plexus, ran vertically in parallel to each other, and each one independently terminated at the right IVC and the right RV. Two right IIVs, connecting each other with small branches, ascended and separately joined the right external iliac vein. The right and left IIVs were connected to each other. These variations cause abnormal drainage, which could lead to clinical symptoms associated with the dysfunction of the vascular and urogenital systems. Here we describe the detailed anatomical features of the area and discuss the related anatomical and developmental aspects.

  17. Breast cancer metastatic to the kidney with renal vein involvement.

    Science.gov (United States)

    Nasu, Hatsuko; Miura, Katsutoshi; Baba, Megumi; Nagata, Masao; Yoshida, Masayuki; Ogura, Hiroyuki; Takehara, Yasuo; Sakahara, Harumi

    2015-02-01

    The common sites of breast cancer metastases include bones, lung, brain, and liver. Renal metastasis from the breast is rare. We report a case of breast cancer metastatic to the kidney with extension into the renal vein. A 40-year-old woman had undergone left mastectomy for breast cancer at the age of 38. A gastric tumor, which was later proved to be metastasis from breast cancer, was detected by endoscopy. Computed tomography performed for further examination of the gastric tumor revealed a large left renal tumor with extension into the left renal vein. It mimicked a primary renal tumor. Percutaneous biopsy of the renal tumor confirmed metastasis from breast cancer. Surgical intervention of the stomach and the kidney was avoided, and she was treated with systemic chemotherapy. Breast cancer metastatic to the kidney may present a solitary renal mass with extension into the renal vein, which mimics a primary renal tumor.

  18. Computed tomography research about the artery and vein of separated pig lung

    International Nuclear Information System (INIS)

    Ji Jiansong; Gong Jianping; Qian Minghui

    2003-01-01

    Objective: To evaluate the artery and vein of the separated lung of pig, and analyse the value of routine CT in differentiating the arteries from veins, and to prove the results by anatomizing, making vessel cast specimens, 3-D reconstruction techniques and so on. Method: Thirty normal fresh pig lungs, GE spiral CT Hispeed/I and workstation, anatomic tools, red and blue dyestuff 100 ml and so on were used. Result: Pig lungs are divided into left, lingua and right lung. 85.7% left lungs have three lobes coded as superior, middle and inferior; 93.75% right have the three lobes coded in the same way. Segments and subsegments can be analysed through thin thickness scanning and MIP of spiral CT; arteries and veins of separated pig lung can be resolved to order of 6-7, by Kassab improved Strahler ordering system, but can only be measured to order 5-6; their angles of going out and going positions of those arteries and veins above segments and below subsegments were statistically different (P<0.05). Conclusion: CT can discriminate the arteries well from the veins to order 11-12 in separated pig lung which demonstrates that CT can differentiate the arterial grain and venous grain

  19. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    Directory of Open Access Journals (Sweden)

    KS Madhusudhan

    2013-01-01

    Full Text Available Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, successfully treated by self-expandable metallic stent.

  20. ARTIFICIAL NEURAL NETWORKS BASED GEARS MATERIAL SELECTION HYBRID INTELLIGENT SYSTEM

    Institute of Scientific and Technical Information of China (English)

    X.C. Li; W.X. Zhu; G. Chen; D.S. Mei; J. Zhang; K.M. Chen

    2003-01-01

    An artificial neural networks(ANNs) based gear material selection hybrid intelligent system is established by analyzing the individual advantages and weakness of expert system (ES) and ANNs and the applications in material select of them. The system mainly consists of tow parts: ES and ANNs. By being trained with much data samples,the back propagation (BP) ANN gets the knowledge of gear materials selection, and is able to inference according to user input. The system realizes the complementing of ANNs and ES. Using this system, engineers without materials selection experience can conveniently deal with gear materials selection.

  1. Carbon dot-Au(i)Ag(0) assembly for the construction of an artificial light harvesting system.

    Science.gov (United States)

    Jana, Jayasmita; Aditya, Teresa; Pal, Tarasankar

    2018-03-06

    Artificial light harvesting systems (LHS) with inorganic counterparts are considered to be robust as well as mechanistically simple, where the system follows the donor-acceptor principle with an unchanged structural pattern. Plasmonic gold or silver nanoparticles are mostly chosen as inorganic counterparts to design artificial LHS. To capitalize on its electron accepting capability, Au(i) has been considered in this work for the synergistic stabilization of a system with intriguingly fluorescing silver(0) clusters produced in situ. Thus a stable fluorescent Au(i)Ag(0) assembly is generated with electron accepting capabilities. On the other hand, carbon dots have evolved as new fluorescent probes due to their unique physicochemical properties. Utilizing the simple electronic behavior of carbon dots, an electronic interaction between the fluorescent Au(i)Ag(0) and a carbon dot has been investigated for the construction of a new artificial light harvesting system. This coinage metal assembly allows surface energy transfer where it acts as an acceptor, while the carbon dot behaves as a good donor. The energy transfer efficiency has been calculated experimentally to be significant (81.3%) and the Au(i)Ag(0)-carbon dot assembly paves the way for efficient artificial LHS.

  2. The Prediction of the Risk Level of Pulmonary Embolism and Deep Vein Thrombosis through Artificial Neural Network.

    Science.gov (United States)

    Agharezaei, Laleh; Agharezaei, Zhila; Nemati, Ali; Bahaadinbeigy, Kambiz; Keynia, Farshid; Baneshi, Mohammad Reza; Iranpour, Abedin; Agharezaei, Moslem

    2016-10-01

    Venous thromboembolism is a common cause of mortality among hospitalized patients and yet it is preventable through detecting the precipitating factors and a prompt diagnosis by specialists. The present study has been carried out in order to assist specialists in the diagnosis and prediction of the risk level of pulmonary embolism in patients, by means of artificial neural network. A number of 31 risk factors have been used in this study in order to evaluate the conditions of 294 patients hospitalized in 3 educational hospitals affiliated with Kerman University of Medical Sciences. Two types of artificial neural networks, namely Feed-Forward Back Propagation and Elman Back Propagation, were compared in this study. Through an optimized artificial neural network model, an accuracy and risk level index of 93.23 percent was achieved and, subsequently, the results have been compared with those obtained from the perfusion scan of the patients. 86.61 percent of high risk patients diagnosed through perfusion scan diagnostic method were also diagnosed correctly through the method proposed in the present study. The results of this study can be a good resource for physicians, medical assistants, and healthcare staff to diagnose high risk patients more precisely and prevent the mortalities. Additionally, expenses and other unnecessary diagnostic methods such as perfusion scans can be efficiently reduced.

  3. Applied anatomic study of testicular veins in adult cadavers and in human fetuses

    Directory of Open Access Journals (Sweden)

    Luciano A. Favorito

    2007-04-01

    Full Text Available OBJECTIVES: Analyze the anatomic variations of the testicular veins in human cadavers and fetuses. MATERIALS AND METHODS: One hundred male adult cadavers and 24 fetuses were studied. Four anatomic aspects were considered: 1 Number of testicular veins, 2 The local of vein termination, 3 Type and number of collaterals present and 4 Testicular vein termination angle. RESULTS: Cadavers - Right side - One testicular vein occurred in 85% and 2 veins in 5% of the cases. There were communicating veins with the colon in 21% of the cases. Left side - One testicular vein occurred in 82%, two veins in 15%, three veins in 2% and four veins in 1% of the cases. There were communicating veins with the colon in 31% of the cases. Fetuses - Right side -One testicular vein occurred in all cases. This vein drained to the vena cava in 83.3% of the cases, to the junction of the vena cava with the renal vein in 12.5% and to the renal vein in 4.2%. There were communicating veins with the colon in 25% of the cases. Left side - One testicular vein occurred in 66.6% of the cases, and 2 veins in occurred 33.3%. Communicating veins with the colon were found in 41.6% of the cases. CONCLUSION: The testicular vein presents numeric variations and also variations in its local of termination. In approximately 30% of the cases, there are collaterals that communicate the testicular vein with retroperitoneal veins. These anatomic findings can help understanding the origin of varicocele and its recurrence after surgical interventions.

  4. Statistical uncertainty of response characteristic of building-appendage system for spectrum-compatible artificial earthquake motion

    International Nuclear Information System (INIS)

    Kurosaki, A.; Kozeki, M.

    1981-01-01

    Spectrum-compatible artificial time histories of ground motions are frequently used for the seismic design of nuclear power plant structures and components. However, statistical uncertainty of the responses of building structures and mechanical components mounted on the building (building-appendage systems) are anticipated, since an artificial time history is no more than one sample from a population of such time histories that match a specified design response spectrum. This uncertainty may spoil the reliability of the seismic design and therefore the extent of the uncertainty of the response characteristic is a matter of great concern. In this paper, above-mentioned uncertainty of the dynamic response characteristics of the building-appendage system to the spectrum-compatible artificial earthquake is investigated. (orig./RW)

  5. VEIN-TYPE URANIUM MINERALIZATION IN THE EASTERN DESERT OF EGYPT

    Directory of Open Access Journals (Sweden)

    M. M. Ghoneim

    2018-03-01

    Full Text Available Vein type uranium deposits where uranium minerals fill cavities veins, fractures, fissures, pore spaces, shear zone, breccia and stockworks in igneous, meta-sediments and metamorphic rocks are common source of uranium mineralization all over the wold. In Egypt, El-Erediya, El-Missikat and El Sela uranium mineralization occur in younger granite plutons in the Eastern Desert of Egypt. These plutons are considered as good examples of intra-granitic vein-type uranium mineralization. The goal of this review article is to study the characteristics of granites and Th-U vein mineralization El Sela area. Main tasks are characteristics of vein type uranium mineralization in the world and Egypt, characteristics of ore-bearing intrusive rocks in the El Sela area, mineralogy of Th-U vein-type mineralization in El Sela area and secondary U and Th minerals in granites. Results. The article revealed that El Sela granite is a peraluminous, high-K Calc-Alkaline (HKCA granite. Two-mica leucogranitic pluton is considered the source rock of U-mineralization at El-Sela area, while the altered microgranite and dolerite dikes are good traps for these mineralizations. The reactivated faults system trending ENE-WSW and NNW-SSE make favorable condition to form uranium mineralization associated with polymetallic mineralization that are redeposited in the two mica granite, microgranite and dolerite dikes. The metallic mineral assemblages in the veins mainly consist of pyrite, chalcopyrite, galena, sphalerite and fluorite that are associated with primary (uraninite, coffinite and secondary U-mineralization (uranophane and autunite that occur either as disseminated clusters or as microfracture filling and coating joint surface. Five types of thorite-group minerals can be distinguished: thorite, Zr-rich thorite, phosphothorite, uranothorite and Zr-rich uranothorite. ThO2 content of uraninite vary from (1.1 to 3 wt.%, for PbO contents from 1.16 to 2.35 wt.%, P2O5 contents from

  6. Current state of total artificial heart therapy and introduction of the most important total artificial heart systems.

    Science.gov (United States)

    Spiliopoulos, Sotirios; Hergesell, Vera; Wasler, Andrae; Dapunt, Otto

    2018-06-14

    Due to the declining instances of organ donation, total artificial heart (TAH) therapy is of increasing importance for the management of end-stage biventricular heart failure. We introduce the currently most important established and novel TAH systems (SynCardia, CARMAT, ReinHeart, BiVACOR), report clinical outcomes and discuss technical requirements for the successful implementation of TAH therapy as an alternative to cardiac transplantation.

  7. Artificial intelligence and expert systems in-flight software testing

    Science.gov (United States)

    Demasie, M. P.; Muratore, J. F.

    1991-01-01

    The authors discuss the introduction of advanced information systems technologies such as artificial intelligence, expert systems, and advanced human-computer interfaces directly into Space Shuttle software engineering. The reconfiguration automation project (RAP) was initiated to coordinate this move towards 1990s software technology. The idea behind RAP is to automate several phases of the flight software testing procedure and to introduce AI and ES into space shuttle flight software testing. In the first phase of RAP, conventional tools to automate regression testing have already been developed or acquired. There are currently three tools in use.

  8. Supracardiac total anomalous pulmonary venous connection with a descending vertical vein.

    Science.gov (United States)

    Shah, Sejal; Singh, Mukesh; John, Colin; Maheshwari, Sunita

    2009-10-01

    The commonly used Darling classification for total anomalous pulmonary venous connection (TAPVC) consists of supracardiac, cardiac, infracardiac, and mixed types (Craig et al., Lab Invest 6:44-64, 1967). In supracardiac TAPVC, the common pulmonary vein drains superiorly into the left innominate vein, the superior vena cava, or the azygos vein by way of an ascending vertical vein. We describe a case of supracardiac TAPVC draining into the azygos vein atypically by way of a descending vertical vein.

  9. Induced chorioretinal venous anastomosis in experimental retinal branch vein occlusion.

    OpenAIRE

    McAllister, I L; Yu, D Y; Vijayasekaran, S; Barry, C; Constable, I

    1992-01-01

    Iatrogenic retinal vein to choroidal vein anastomoses were created using laser photocoagulation in six of seven dog eyes in which a partial branch retinal vein occlusion had previously been created photochemically. A similar attempt to create an anastomosis was made in six control eyes in which no branch vein occlusion was present. In the eyes in which a branch retinal vein had been created, a venous chorioretinal anastomosis appeared to be present by 3 to 6 weeks. In three control eyes simil...

  10. Optimization of an artificial-recharge-pumping system for water supply in the Maghaway Valley, Cebu, Philippines

    Science.gov (United States)

    Kawo, Nafyad Serre; Zhou, Yangxiao; Magalso, Ronnell; Salvacion, Lasaro

    2018-05-01

    A coupled simulation-optimization approach to optimize an artificial-recharge-pumping system for the water supply in the Maghaway Valley, Cebu, Philippines, is presented. The objective is to maximize the total pumping rate through a system of artificial recharge and pumping while meeting constraints such as groundwater-level drawdown and bounds on pumping rates at each well. The simulation models were coupled with groundwater management optimization to maximize production rates. Under steady-state natural conditions, the significant inflow to the aquifer comes from river leakage, whereas the natural discharge is mainly the subsurface outflow to the downstream area. Results from the steady artificial-recharge-pumping simulation model show that artificial recharge is about 20,587 m3/day and accounts for 77% of total inflow. Under transient artificial-recharge-pumping conditions, artificial recharge varies between 14,000 and 20,000 m3/day depending on the wet and dry seasons, respectively. The steady-state optimisation results show that the total optimal abstraction rate is 37,545 m3/day and artificial recharge is increased to 29,313 m3/day. The transient optimization results show that the average total optimal pumping rate is 36,969 m3/day for the current weir height. The transient optimization results for an increase in weir height by 1 and 2 m show that the average total optimal pumping rates are increased to 38,768 and 40,463 m3/day, respectively. It is concluded that the increase in the height of the weir can significantly increase the artificial recharge rate and production rate in Maghaway Valley.

  11. Radiation Retinopathy Associated with Central Retinal Vein Occlusion

    Institute of Scientific and Technical Information of China (English)

    Yan; Liu; FengWen

    2007-01-01

    Purpose: To report a case of radiation retinopathy associated with central retinal vein occlusion.Methods: The clinical features and fundus fluorescein angiography of this case were analyzed.Results: The patient had been treated with radiotherapy for her nasopharyngeal carcinoma, and presented with sudden visual loss in the left eye. The funduscopic examination and fluorescein angiography showed the features of radiation retinopathy in both eyes, and central retinal vein occlusion in the left eye.Conclusions: Radiation retinopathy can be associated with central retinal vein occlusion in the same eye, and it seems that the endothelial cell loss caused by radiation retinopathy may lead to retinal vein occlusion.

  12. Artificial intelligence guides system's best practices, cutting costs and improving services.

    Science.gov (United States)

    1999-06-01

    One for the history books. Clinical care improvement initiatives guided by a sophisticated artificial intelligence program have helped a major Virginia integrated health system make dramatic improvements in the cost and quality of its health care services. Find out how the technological innovation has earned Sentara Health System a place in the permanent collection of the Smithsonian's National Museum of American History.

  13. Disastrous Portal Vein Embolization Turned into a Successful Intervention

    Energy Technology Data Exchange (ETDEWEB)

    Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland); Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at [Universitätsklinikum St. Pölten-Lilienfeld, Institute of Medical Radiology, Diagnostic, Intervention (Austria); Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch; Kara, Levent, E-mail: levent.kara@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland)

    2015-10-15

    Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

  14. A Review of Intelligent Driving Style Analysis Systems and Related Artificial Intelligence Algorithms

    Directory of Open Access Journals (Sweden)

    Gys Albertus Marthinus Meiring

    2015-12-01

    Full Text Available In this paper the various driving style analysis solutions are investigated. An in-depth investigation is performed to identify the relevant machine learning and artificial intelligence algorithms utilised in current driver behaviour and driving style analysis systems. This review therefore serves as a trove of information, and will inform the specialist and the student regarding the current state of the art in driver style analysis systems, the application of these systems and the underlying artificial intelligence algorithms applied to these applications. The aim of the investigation is to evaluate the possibilities for unique driver identification utilizing the approaches identified in other driver behaviour studies. It was found that Fuzzy Logic inference systems, Hidden Markov Models and Support Vector Machines consist of promising capabilities to address unique driver identification algorithms if model complexity can be reduced.

  15. Artificial intelligence costs, benefits, and risks for selected spacecraft ground system automation scenarios

    Science.gov (United States)

    Truszkowski, Walter F.; Silverman, Barry G.; Kahn, Martha; Hexmoor, Henry

    1988-01-01

    In response to a number of high-level strategy studies in the early 1980s, expert systems and artificial intelligence (AI/ES) efforts for spacecraft ground systems have proliferated in the past several years primarily as individual small to medium scale applications. It is useful to stop and assess the impact of this technology in view of lessons learned to date, and hopefully, to determine if the overall strategies of some of the earlier studies both are being followed and still seem relevant. To achieve that end four idealized ground system automation scenarios and their attendant AI architecture are postulated and benefits, risks, and lessons learned are examined and compared. These architectures encompass: (1) no AI (baseline); (2) standalone expert systems; (3) standardized, reusable knowledge base management systems (KBMS); and (4) a futuristic unattended automation scenario. The resulting artificial intelligence lessons learned, benefits, and risks for spacecraft ground system automation scenarios are described.

  16. Artificial Intelligence in Civil Engineering

    Directory of Open Access Journals (Sweden)

    Pengzhen Lu

    2012-01-01

    Full Text Available Artificial intelligence is a branch of computer science, involved in the research, design, and application of intelligent computer. Traditional methods for modeling and optimizing complex structure systems require huge amounts of computing resources, and artificial-intelligence-based solutions can often provide valuable alternatives for efficiently solving problems in the civil engineering. This paper summarizes recently developed methods and theories in the developing direction for applications of artificial intelligence in civil engineering, including evolutionary computation, neural networks, fuzzy systems, expert system, reasoning, classification, and learning, as well as others like chaos theory, cuckoo search, firefly algorithm, knowledge-based engineering, and simulated annealing. The main research trends are also pointed out in the end. The paper provides an overview of the advances of artificial intelligence applied in civil engineering.

  17. Artificial Intelligence in Astronomy

    Science.gov (United States)

    Devinney, E. J.; Prša, A.; Guinan, E. F.; Degeorge, M.

    2010-12-01

    From the perspective (and bias) as Eclipsing Binary researchers, we give a brief overview of the development of Artificial Intelligence (AI) applications, describe major application areas of AI in astronomy, and illustrate the power of an AI approach in an application developed under the EBAI (Eclipsing Binaries via Artificial Intelligence) project, which employs Artificial Neural Network technology for estimating light curve solution parameters of eclipsing binary systems.

  18. The usefulness and the limitation of MR angiography for the evaluation of colateral veins in portal hypertension

    International Nuclear Information System (INIS)

    Komazaki, Toshio

    1994-01-01

    The usefulness and the limitation of magnetic resonance angiography (MRA) for the assessment of the portal vein and its branches, i.e., the collateral veins of portal hypertensive patients, were studied. In a total of 22 patients with portal hypertension, both MRA and percutaneous transhepatic portography (PTP) were done at the same time. MRA and PTP images were read at random by three observers. The discriminative scores, decided from the grades of clearness of images, were calculated for six portal venous vessels. The discrimination of the portal vein, splenic vein, paraumbilical vein and gastrorenal shunt was easy on condition that they were clearly visualized by PTP. Thus the accuracy of MRA, which was calculated by comparing it with PTP, the gold standard, was high and above 95%. Regarding the left gastric vein and short gastric vein, the accuracy of MRA were lower than the former four vessels but were still above 80%. MRA, the noninvasive method, seems useful for the first choice to see the total image of portal venous system. (author)

  19. Design of a portable artificial heart drive system based on efficiency analysis.

    Science.gov (United States)

    Kitamura, T

    1986-11-01

    This paper discusses a computer simulation of a pneumatic portable piston-type artificial heart drive system with a linear d-c-motor. The purpose of the design is to obtain an artificial heart drive system with high efficiency and small dimensions to enhance portability. The design employs two factors contributing the total efficiency of the drive system. First, the dimensions of the pneumatic actuator were optimized under a cost function of the total efficiency. Second, the motor performance was studied in terms of efficiency. More than 50 percent of the input energy of the actuator with practical loads is consumed in the armature circuit in all linear d-c-motors with brushes. An optimal design is: the piston cross-sectional area of 10.5 cm2 cylinder longitudinal length of 10 cm. The total efficiency could be up to 25 percent by improving the gasket to reduce the frictional force.

  20. Reasoning methods in medical consultation systems: artificial intelligence approaches.

    Science.gov (United States)

    Shortliffe, E H

    1984-01-01

    It has been argued that the problem of medical diagnosis is fundamentally ill-structured, particularly during the early stages when the number of possible explanations for presenting complaints can be immense. This paper discusses the process of clinical hypothesis evocation, contrasts it with the structured decision making approaches used in traditional computer-based diagnostic systems, and briefly surveys the more open-ended reasoning methods that have been used in medical artificial intelligence (AI) programs. The additional complexity introduced when an advice system is designed to suggest management instead of (or in addition to) diagnosis is also emphasized. Example systems are discussed to illustrate the key concepts.

  1. Management of reticular veins and telangiectases.

    Science.gov (United States)

    Smith, Philip Coleridge

    2015-11-01

    To review the literature related to the management of reticular varices and telangiectases of the lower limbs to provide guidance on the treatment of these veins. Very few randomised clinical trials are available in this field. A European Guideline has been published on the treatment of reticular varices and telangiectases, which is largely based on the opinion of experts. Older accounts written by individual phlebologists contain extensive advice from their own practice, which is valuable in identifying effective methods of sclerotherapy. All accounts indicate that a history should be taken combined with a clinical and ultrasound examination to establish the full extent of the venous disease. Sclerotherapy is commenced by injecting the larger veins first of all, usually the reticular varices. Later in the same session or in subsequent sessions, telangiectases can be treated by direct injection. Following treatment, the application of class 2 compression stockings for a period of up to three weeks is beneficial but not used universally by all phlebologists. Further sessions can follow at intervals of 2-8 weeks in which small residual veins are treated. Resistant veins can be managed by ultrasound-guided injection of underlying perforating veins and varices. Other treatments including RF diathermy and laser ablation of telangiectases have very limited efficacy in this condition. Sclerotherapy, when used with the correct technique, is the most effective method for the management of reticular varices and telangiectases. © The Author(s) 2015.

  2. The implementation of artificial intelligence in control systems

    International Nuclear Information System (INIS)

    Koul, R.; Weygand, D.P.

    1987-01-01

    Some concepts of artificial intelligence are reviewed, particularly as they apply to control systems of accelerators. Logical representation and formal reasoning are discussed briefly, as well as production systems, which describe various systems based on the idea of condition-action pairs (productions). Procedural knowledge, which deals with routine activities that rarely require change, is described. Frames are defined, which provide a convenient structure for representing knowledge. Frames consist of information about objects. For a given frame there are various slots, and for each slot there are various facets, each containing various data. Direct analogical representation is defined as a class of representation which represents knowledge in a natural analog manner, allowing observation of facts in many cases to be achieved quickly and easily compared to deduction. Architecture of systems applied to accelerator control is then described

  3. Kinetics of vein graft hyperplasia

    International Nuclear Information System (INIS)

    Zwolak, R.M.; Adams, M.C.; Clowes, A.W.

    1986-01-01

    Human aortocoronary vein grafts fail due to accelerated occlusive disease. The possibility that this is related to cellular hyperplasia was investigated in a rabbit model where kinetics of vein graft thickening, endothelial (EC) repair, and smooth muscle cell (SMC) proliferation were measured from 2 days to 24 weeks after implanting jugular vein segments in the carotid artery. Immediately after graft placement focal EC denudation was observed. These defects were repaired within 1 week and did not recur. By 4 weeks intimal area had increased 30 fold from 0.028 +/- 0.004 to 0.705 +/- 0.021 mm 2 , and a 24 weeks was 0.93 +/- 0.21 mm 2 . This response did not produce a reduction in graft lumen area. EC and SMC thymidine-labeling index were measured by en face and cross-section autoradiography after injection of 3 H-thymidine and perfusion fixation. Despite rapid EC surface repair EC labeling index remained elevated and only returned to normal levels at 12 weeks; SMC labeling was 10 fold greater than baseline even at 24 weeks (0.22% vs 0.02%). SMC mass demonstrated morphometrically increased between 2 and 12 weeks. Intimal thickening in vein grafts is due to SMC proliferation and develops after the EC layer has been restored. In contrast, intimal SMC proliferate in damaged arteries when the EC layer is absent and cease when the EC layer is regenerated

  4. Interventional treatment for the occlusive hepatic veins in Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Zhang Xitong; Xu Ke; Feng Bo; Su Hongying; Li Hong; Zu Maoheng; Cui Jingguo; Yang Xueliang; Zhao Jinxu; Chen Kai

    2003-01-01

    Objective: To evaluate the interventional methods for occlusive hepatic veins in Budd-Chiari syndrome and its mid and long-term effects. Methods: Forty-two patients (male 17 cases and female 25 cases) aged from 18 to 57 years old (mean 34.5 years) were studied. The liver functions were Child A in 23 cases, Child B in 6 cases, and Child C in 13 cases, respectively. A total of 92 hepatic veins were occluded. Among them, 29 left hepatic veins, 24 middle hepatic veins, 36 right hepatic veins, and 3 accessory hepatic veins were occluded. Thirty-four patients were accompanied with the stenotic or occlusive inferior vena cave (IVC) . The interventional methods included: (1) recanalization of occlusive hepatic veins (by transjugular, transfemoral, and percutaneous transhepatic route, or the combination of above three methods); (2) percutaneous transluminal angioplasty; (3) self-expanding stent implantation. The occlusive IVC in 32 patients also accepted PTA and/or stent implantation. Results: The successful recanalization was carried out in forty hepatic veins in 40 patients. PTA of occlusive veins was followed by stent implantation in 8 patients. The pressure of hepatic veins dropped from 34.5 cm H 2 O (25.0-48.0 cm H 2 O) to 22.0 cm H 2 O (12.0-35.0 cm H 2 O) after intervention (T=11.50, P < 0.01). The symptoms and pathological signs improved obviously in 32 cases and improved partly in 8 cases. During the follow-up period from 1 month to 54 months (mean 27.5 months), one cases died of liver function failure at one month after intervention. The re-intervention of occlusive veins in two cases were performed and the better results were acquired again. Five cases didn't accept re-intervention. Neither recurrence of symptoms nor re-occlusion of hepatic veins was found in the other 32 patients. Conclusion: (1) Multiple and synthetical interventional methods for the occlusive hepatic veins in Budd-Chiari syndrome can be utilized. (2) The intervention of hepatic vein is mini

  5. Special Issue: New trends and applications on hybrid artificial intelligence systems

    OpenAIRE

    Corchado Rodríguez, Emilio; Graña Romay, Manuel; Woźniak, MichaŁ

    2017-01-01

    This Special Issue is an outgrowth of the HAIS'10, the 5th International Conference on Hybrid Artificial Intelligence Systems, which was held in San Sebastián, Spain, 23–25 June 2010. The HAIS conference series is devoted to the presentation of innovative techniques involving the hybridization of emerging and active topics in data mining and decision support systems, information fusion, evolutionary computation, visualization techniques, ensemble models, intelligent agent-based systems (compl...

  6. Geometric Distribution-Based Readers Scheduling Optimization Algorithm Using Artificial Immune System

    Directory of Open Access Journals (Sweden)

    Litian Duan

    2016-11-01

    Full Text Available In the multiple-reader environment (MRE of radio frequency identification (RFID system, multiple readers are often scheduled to interrogate the randomized tags via operating at different time slots or frequency channels to decrease the signal interferences. Based on this, a Geometric Distribution-based Multiple-reader Scheduling Optimization Algorithm using Artificial Immune System (GD-MRSOA-AIS is proposed to fairly and optimally schedule the readers operating from the viewpoint of resource allocations. GD-MRSOA-AIS is composed of two parts, where a geometric distribution function combined with the fairness consideration is first introduced to generate the feasible scheduling schemes for reader operation. After that, artificial immune system (including immune clone, immune mutation and immune suppression quickly optimize these feasible ones as the optimal scheduling scheme to ensure that readers are fairly operating with larger effective interrogation range and lower interferences. Compared with the state-of-the-art algorithm, the simulation results indicate that GD-MRSOA-AIS could efficiently schedules the multiple readers operating with a fairer resource allocation scheme, performing in larger effective interrogation range.

  7. SIFT Based Vein Recognition Models: Analysis and Improvement

    Directory of Open Access Journals (Sweden)

    Guoqing Wang

    2017-01-01

    Full Text Available Scale-Invariant Feature Transform (SIFT is being investigated more and more to realize a less-constrained hand vein recognition system. Contrast enhancement (CE, compensating for deficient dynamic range aspects, is a must for SIFT based framework to improve the performance. However, evidence of negative influence on SIFT matching brought by CE is analysed by our experiments. We bring evidence that the number of extracted keypoints resulting by gradient based detectors increases greatly with different CE methods, while on the other hand the matching result of extracted invariant descriptors is negatively influenced in terms of Precision-Recall (PR and Equal Error Rate (EER. Rigorous experiments with state-of-the-art and other CE adopted in published SIFT based hand vein recognition system demonstrate the influence. What is more, an improved SIFT model by importing the kernel of RootSIFT and Mirror Match Strategy into a unified framework is proposed to make use of the positive keypoints change and make up for the negative influence brought by CE.

  8. Multisensor system and artificial intelligence in housing for the elderly.

    Science.gov (United States)

    Chan, M; Bocquet, H; Campo, E; Val, T; Estève, D; Pous, J

    1998-01-01

    To improve the safety of a growing proportion of elderly and disabled people in the developed countries, a multisensor system based on Artificial Intelligence (AI), Advanced Telecommunications (AT) and Information Technology (IT) has been devised and fabricated. Thus, the habits and behaviours of these populations will be recorded without disturbing their daily activities. AI will diagnose any abnormal behavior or change and the system will warn the professionals. Gerontology issues are presented together with the multisensor system, the AI-based learning and diagnosis methodology and the main functionalities.

  9. Influence of leaf vein density and thickness on hydraulic conductance and photosynthesis in rice (Oryza sativa L.) during water stress.

    Science.gov (United States)

    Tabassum, Muhammad Adnan; Zhu, Guanglong; Hafeez, Abdul; Wahid, Muhammad Atif; Shaban, Muhammad; Li, Yong

    2016-11-16

    The leaf venation architecture is an ideal, highly structured and efficient irrigation system in plant leaves. Leaf vein density (LVD) and vein thickness are the two major properties of this system. Leaf laminae carry out photosynthesis to harvest the maximum biological yield. It is still unknown whether the LVD and/or leaf vein thickness determines the plant hydraulic conductance (K plant ) and leaf photosynthetic rate (A). To investigate this topic, the current study was conducted with two varieties under three PEG-induced water deficit stress (PEG-IWDS) levels. The results showed that PEG-IWDS significantly decreased A, stomatal conductance (g s ), and K plant in both cultivars, though the IR-64 strain showed more severe decreases than the Hanyou-3 strain. PEG-IWDS significantly decreased the major vein thickness, while it had no significant effect on LVD. A, g s and K plant were positively correlated with each other, and they were negatively correlated with LVD. A, g s and K plant were positively correlated with the inter-vein distance and major vein thickness. Therefore, the decreased photosynthesis and hydraulic conductance in rice plants under water deficit conditions are related to the decrease in the major vein thickness.

  10. Recurrence of pulmonary vein conduction and atrial fibrillation after pulmonary vein isolation for atrial fibrillation

    DEFF Research Database (Denmark)

    Nilsson, Brian; Chen, Xu; Pehrson, Steen

    2006-01-01

    BACKGROUND: Both segmental ostial and circumferential extraostial pulmonary vein (PV) isolation have been proven effective in the treatment of atrial fibrillation (AF). However, the recurrence of AF and PV conduction after the 2 ablation strategies has never been compared in a randomized study...... isolation. Extraostial PV isolation was performed by encircling the paired left and right PVs, respectively, guided by an electroanatomic mapping system. RESULTS: A total of 84% of the patients had recurrent AF after the first PV isolation procedure, showing 72% with AF and 12% with organized left atrial...

  11. Reinforcement Learning Based Artificial Immune Classifier

    Directory of Open Access Journals (Sweden)

    Mehmet Karakose

    2013-01-01

    Full Text Available One of the widely used methods for classification that is a decision-making process is artificial immune systems. Artificial immune systems based on natural immunity system can be successfully applied for classification, optimization, recognition, and learning in real-world problems. In this study, a reinforcement learning based artificial immune classifier is proposed as a new approach. This approach uses reinforcement learning to find better antibody with immune operators. The proposed new approach has many contributions according to other methods in the literature such as effectiveness, less memory cell, high accuracy, speed, and data adaptability. The performance of the proposed approach is demonstrated by simulation and experimental results using real data in Matlab and FPGA. Some benchmark data and remote image data are used for experimental results. The comparative results with supervised/unsupervised based artificial immune system, negative selection classifier, and resource limited artificial immune classifier are given to demonstrate the effectiveness of the proposed new method.

  12. Structural and functional responses of extremity veins to long-term gravitational loading or unloading—lessons from animal systems

    Science.gov (United States)

    Monos, Emil; Raffai, Gábor; Dörnyei, Gabriella; Nádasy, György L.; Fehér, Erzsébet

    2007-02-01

    Long, transparent tubular tilt-cages were developed to maintain experimental rats either in 45∘ head-up (orthostasis model), or in 45∘ head-down body position (antiorthostasis model) for several weeks. In order to study the functional and structural changes in extremity blood vessels, also novel pressure angiograph systems, as well as special quantitative electron microscopic methods were applied. It was found that several adaptive mechanisms are activated in the lower limb superficial veins and microvessels of muscles when an organism is exposed to long-term (1-2 weeks) orthostatic-type gravitational load including a reversible amplification of the pressure-dependent myogenic response, tuning of the myogenic tone by Ca++- and voltage-sensitive K+ channels in humans, augmentation of the intramural sympathetic innervation involving an increased nerve terminal density and synaptic vesicle count with functional remodeling, reorganization of vascular network properties (microvascular rarefaction in muscles, decreased branching angles in superficial veins), and responses of an endothelin and platelet-derived growth factor (PDGF) containing vesicle system in the endothelium. On the other hand, when applying long-term head-down tilting, the effects are dichotomous, e.g. it suppresses significantly the pressure-induced myogenic response, however does not diminish the adventitial sympathetic innervation density.

  13. Artificial Immune Networks: Models and Applications

    Directory of Open Access Journals (Sweden)

    Xian Shen

    2008-06-01

    Full Text Available Artificial Immune Systems (AIS, which is inspired by the nature immune system, has been applied for solving complex computational problems in classification, pattern rec- ognition, and optimization. In this paper, the theory of the natural immune system is first briefly introduced. Next, we compare some well-known AIS and their applications. Several representative artificial immune networks models are also dis- cussed. Moreover, we demonstrate the applications of artificial immune networks in various engineering fields.

  14. Generating and analyzing synthetic finger vein images

    NARCIS (Netherlands)

    Hillerström, Fieke; Kumar, Ajay; Veldhuis, Raymond N.J.

    2014-01-01

    Abstract: The finger-vein biometric offers higher degree of security, personal privacy and strong anti-spoofing capabilities than most other biometric modalities employed today. Emerging privacy concerns with the database acquisition and lack of availability of large scale finger-vein database have

  15. Complications of umbilical vein catherisation. Case Report

    International Nuclear Information System (INIS)

    Bothur-Nowacka, J.; Czech-Kowalska, J.; Gruszfeld, D.; Nowakowska-Rysz, M.; Dobrzanska, A.; Kosciesza, A.; Polnik, D.

    2011-01-01

    Umbilical vein catheterization is a relatively easy procedure performed routinely on the neonate intensive care units. It provides a fast central vein access, but some complications have been described in the literature. Case Reports: We presented a case report of a premature infant (34 hbd) with extravasation of the parenteral nutrition and drugs to the liver after umbilical vein catheterization. Fever and increasing biochemical markers of infection were observed. USG revealed a heterogenic, well-limited space of 4 cm in diameter, located in the right lobe of the liver. CT excluded liver abscess. Considering neoplastic process or incorrect location of the catheter of the central vein, we performed liver biopsy. Results: Cytological and biochemical analysis of the aspirated fluid revealed extravasation of parenteral nutrition to the liver.Our case confirms the necessity of controlling a proper location of the central catheter right after its insertion and during hospitalization. (authors)

  16. SHARP: A multi-mission artificial intelligence system for spacecraft telemetry monitoring and diagnosis

    Science.gov (United States)

    Lawson, Denise L.; James, Mark L.

    1989-01-01

    The Spacecraft Health Automated Reasoning Prototype (SHARP) is a system designed to demonstrate automated health and status analysis for multi-mission spacecraft and ground data systems operations. Telecommunications link analysis of the Voyager 2 spacecraft is the initial focus for the SHARP system demonstration which will occur during Voyager's encounter with the planet Neptune in August, 1989, in parallel with real time Voyager operations. The SHARP system combines conventional computer science methodologies with artificial intelligence techniques to produce an effective method for detecting and analyzing potential spacecraft and ground systems problems. The system performs real time analysis of spacecraft and other related telemetry, and is also capable of examining data in historical context. A brief introduction is given to the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory. The current method of operation for monitoring the Voyager Telecommunications subsystem is described, and the difficulties associated with the existing technology are highlighted. The approach taken in the SHARP system to overcome the current limitations is also described, as well as both the conventional and artificial intelligence solutions developed in SHARP.

  17. [Treatment of nontumoral portal vein thrombosis in cirrhosis].

    Science.gov (United States)

    Bañares, Rafael; Catalina, María-Vega

    2014-07-01

    Portal vein thrombosis in cirrhosis is a relatively common complication associated with the presence of an accompanying prothrombotic phenotype of advanced cirrhosis. The consequences of portal vein thrombosis are relevant because it can be associated with impaired hepatic function, might contraindicate hepatic transplantation and could increase morbidity in the surgical procedure. There is controversy concerning the most effective treatment of portal vein thrombosis, which is based on information that is seldom robust and whose primary objective is to achieve a return to vessel patency. Various studies have suggested that starting anticoagulation therapy early is associated with portal vein repatency more frequently than without treatment and has a low rate of complications. There are no proven data on the type of anticoagulant (low-molecular-weight heparins or dicoumarin agents) and the treatment duration. The implementation of TIPS is technically feasible in thrombosis without cavernous transformation and is associated with portal vein recanalization in a significant proportion of cases. Thrombolytic therapy does not appear to present an adequate balance between efficacy and safety; its use is therefore not supported for this indication. The proper definition of treatment for portal vein thrombosis requires properly designed studies to delimit the efficacy and safety of the various alternatives. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  18. Chicken primordial germ cells use the anterior vitelline veins to enter the embryonic circulation

    Directory of Open Access Journals (Sweden)

    Ana De Melo Bernardo

    2012-09-01

    During gastrulation, chicken primordial germ cells (PGCs are present in an extraembryonic region of the embryo from where they migrate towards the genital ridges. This is also observed in mammals, but in chicken the vehicle used by the migratory PGCs is the vascular system. We have analysed the migratory pathway of chicken PGCs, focusing on the period of transition from the extraembryonic region to the intraembryonic vascular system. Our findings show that at Hamburger and Hamilton developmental stage HH12–HH14 the majority of PGCs concentrate axially in the sinus terminalis and favour transport axially via the anterior vitelline veins into the embryonic circulation. Moreover, directly blocking the blood flow through the anterior vitelline veins resulted in an accumulation of PGCs in the anterior region and a decreased number of PGCs in the genital ridges. We further confirmed the key role for the anterior vitelline veins in the correct migration of PGCs using an ex ovo culture method that resulted in defective morphogenetic development of the anterior vitelline veins. We propose a novel model for the migratory pathway of chicken PGCs whereby the anterior vitelline veins play a central role at the extraembryonic and embryonic interface. The chicken model of PGC migration through the vasculature may be a powerful tool to study the process of homing (inflammation and metastasis due to the striking similarities in regulatory signaling pathways (SDF1–CXCR4 and the transient role of the vasculature.

  19. Natural fracking and the genesis of five-element veins

    Science.gov (United States)

    Markl, Gregor; Burisch, Mathias; Neumann, Udo

    2016-08-01

    Hydrothermal Ag-Co-Ni-Bi-As (five-element vein type) ore deposits show very conspicuous textures of the native elements silver, bismuth, and arsenic indicating formation from a rapid, far-from-equilibrium process. Such textures include up to dm-large tree- and wire-like aggregates overgrown by Co-Ni-Fe arsenides and mostly carbonates. Despite the historical and contemporary importance of five-element vein type deposits as sources of silver, bismuth, and cobalt, and despite of spectacular museum specimens, their process of formation is not yet understood and has been a matter of debate since centuries. We propose, based on observations from a number of classical European five-element vein deposits and carbon isotope analyses, that "natural fracking," i.e., liberation of hydrocarbons or hydrocarbon-bearing fluids during break up of rocks in the vicinity of an active hydrothermal system and mixing between these hydrocarbons (e.g., methane and/or methane-bearing fluids) and a metal-rich hydrothermal fluid is responsible for ore precipitation and the formation of the unusual ore textures and assemblages. Thermodynamic and isotope mixing calculations show that the textural, chemical, and isotopic features of the investigated deposits can entirely be explained by this mechanism.

  20. Catheter Displacement into Inferior Epigastric Vein Causing Local Phlebitis and Cellulitis

    Directory of Open Access Journals (Sweden)

    Noriko Hattori

    2012-01-01

    Full Text Available Catheter insertion for intravenous hyperalimentation is a commonly and widely used clinical technique. When compared with the incidence of complications associated with insertions into the internal jugular vein or the subclavian vein, complications associated with insertions into the femoral vein are less frequent. In this paper, we describe a very rare complication of femoral vein catheter insertion—namely, catheter displacement into the inferior epigastric vein.

  1. Renal Vein Reconstruction for Harvesting Injury in Kidney Transplantation

    Directory of Open Access Journals (Sweden)

    Birkan Bozkurt

    2014-03-01

    Full Text Available Kidney transplantation is the best treatment choice in the end-stage renal disease. In the renal transplantation, renal vein damage or shortness which occurs during cadaveric or living donor nephrectomy causes technical difficulties for surgeons. The lack of the donors already especially cadaveric, the acquirement of the graft, gets very much importance. In this report, it is aimed to share the clinical experiment by which it seen, how anastomosis can become appropriate by using the renal vein which is damaged in the way that anastomosis cannot be done anyway by using cadaveric vena cava graft. The renal vein brought to length for anostomosis which is repaired by using cadaveric vena cava graft, is anastomosed successfully by becoming an end-to-side of the external iliac vein of the recipient. Vascular anastomoses are applied easily in technique. The time of the warm ischemia was under 2 hours and the kidney was functional in the post-operative period. Renal vein trombosis was not observed. The renal vein damage occured during cadaveric or living donor nephrectomy, can be repaired by some methods. In the kidneys in which vein requirement is done, the success rates are rather high although acute tubular necrosis and delayed function can be seen more.

  2. Artificial lateral-line system for imaging dipole sources using Beamforming techniques

    NARCIS (Netherlands)

    Dagamseh, A.M.K.; Wiegerink, Remco J.; Lammerink, Theodorus S.J.; Krijnen, Gijsbertus J.M.

    In nature, fish have the ability to localize prey, school, navigate, etc. using the lateral-line organ [1]. Here we present the use of biomimetic artificial hair-based flow-sensors arranged as lateral-line system in combination with beamforming techniques for dipole source localization in air.

  3. Identification of mathematical model of human breathing in systemArtificial lungs – self-contained breathing apparatus”

    Science.gov (United States)

    Onevsky, P. M.; Onevsky, M. P.; Pogonin, V. A.

    2018-03-01

    The structure and mathematical models of the main subsystems of the control system of the “Artificial Lungs” are presented. This structure implements the process of imitation of human external respiration in the systemArtificial lungs - self-contained breathing apparatus”. A presented algorithm for parametric identification of the model is based on spectral operators, which allows using it in real time.

  4. Predicting IVF Outcome: A Proposed Web-based System Using Artificial Intelligence.

    Science.gov (United States)

    Siristatidis, Charalampos; Vogiatzi, Paraskevi; Pouliakis, Abraham; Trivella, Marialenna; Papantoniou, Nikolaos; Bettocchi, Stefano

    2016-01-01

    To propose a functional in vitro fertilization (IVF) prediction model to assist clinicians in tailoring personalized treatment of subfertile couples and improve assisted reproduction outcome. Construction and evaluation of an enhanced web-based system with a novel Artificial Neural Network (ANN) architecture and conformed input and output parameters according to the clinical and bibliographical standards, driven by a complete data set and "trained" by a network expert in an IVF setting. The system is capable to act as a routine information technology platform for the IVF unit and is capable of recalling and evaluating a vast amount of information in a rapid and automated manner to provide an objective indication on the outcome of an artificial reproductive cycle. ANNs are an exceptional candidate in providing the fertility specialist with numerical estimates to promote personalization of healthcare and adaptation of the course of treatment according to the indications. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  5. A Modular Artificial Intelligence Inference Engine System (MAIS) for support of on orbit experiments

    Science.gov (United States)

    Hancock, Thomas M., III

    1994-01-01

    This paper describes a Modular Artificial Intelligence Inference Engine System (MAIS) support tool that would provide health and status monitoring, cognitive replanning, analysis and support of on-orbit Space Station, Spacelab experiments and systems.

  6. Evaluation of articulation simulation system using artificial maxillectomy models.

    Science.gov (United States)

    Elbashti, M E; Hattori, M; Sumita, Y I; Taniguchi, H

    2015-09-01

    Acoustic evaluation is valuable for guiding the treatment of maxillofacial defects and determining the effectiveness of rehabilitation with an obturator prosthesis. Model simulations are important in terms of pre-surgical planning and pre- and post-operative speech function. This study aimed to evaluate the acoustic characteristics of voice generated by an articulation simulation system using a vocal tract model with or without artificial maxillectomy defects. More specifically, we aimed to establish a speech simulation system for maxillectomy defect models that both surgeons and maxillofacial prosthodontists can use in guiding treatment planning. Artificially simulated maxillectomy defects were prepared according to Aramany's classification (Classes I-VI) in a three-dimensional vocal tract plaster model of a subject uttering the vowel /a/. Formant and nasalance acoustic data were analysed using Computerized Speech Lab and the Nasometer, respectively. Formants and nasalance of simulated /a/ sounds were successfully detected and analysed. Values of Formants 1 and 2 for the non-defect model were 675.43 and 976.64 Hz, respectively. Median values of Formants 1 and 2 for the defect models were 634.36 and 1026.84 Hz, respectively. Nasalance was 11% in the non-defect model, whereas median nasalance was 28% in the defect models. The results suggest that an articulation simulation system can be used to help surgeons and maxillofacial prosthodontists to plan post-surgical defects that will be facilitate maxillofacial rehabilitation. © 2015 John Wiley & Sons Ltd.

  7. Inteligencia artificial en vehiculo

    OpenAIRE

    Amador Díaz, Pedro

    2012-01-01

    Desarrollo de un robot seguidor de líneas, en el que se implementan diversas soluciones de las áreas de sistemas embebidos e inteligencia artificial. Desenvolupament d'un robot seguidor de línies, en el qual s'implementen diverses solucions de les àrees de sistemes encastats i intel·ligència artificial. Follower robot development of lines, in which various solutions are implemented in the areas of artificial intelligence embedded systems.

  8. Congestive index of portal vein

    International Nuclear Information System (INIS)

    Kim, Won Ho; Kim, H. K.; Lee, S. C.; Han, S. H.; Han, K. H.; Chung, J. B.; Choi, H. J.

    1989-01-01

    In patients with portal hypertension, the blood flow volume is maintained despite decreased blood flow velocity due to enlargement of the vascular cross sectional area. Thus, the 'congestion index' of the portal vein, which is the ratio between the cross sectional area (cm2) and the blood flow velocity (cm/sec) determined by a Doppler ultrasonography, may be a sensitive index by which to assess portal hypertension. We performed Doppler ultrasonography on 24 normal subjects, 14 patients with biopsy proved chronic active hepatitis and 55 patients with liver cirrhosis in order to assess the diagnostic value of the congestion index. The cross sectional area of the portal vein was significantly enlarged and the mean blood flow velocity was significantly reduced in patients with liver cirrhosis compared with controls. However, the blood flow volume was no difference. The congestion index of the portal vein was significantly increased in patients with liver cirrhosis (0.113+0.035) compared with patients with chronic active hepatitis(0.078+0.029) (p<0.001) and controls (0.053+0.016) (p<0.001). The sensitivity, specificity and predictability of the congestion index for detection of patients with the cirrhosis of the liver were 76.4%, 100% and 100% respectively, when the normal range was set at mean+2SD. The results suggest that the congestion index of the portal vein may pla a significant role in diagnosis of portal hypertensive patients

  9. Soft computing in artificial intelligence

    CERN Document Server

    Matson, Eric

    2014-01-01

    This book explores the concept of artificial intelligence based on knowledge-based algorithms. Given the current hardware and software technologies and artificial intelligence theories, we can think of how efficient to provide a solution, how best to implement a model and how successful to achieve it. This edition provides readers with the most recent progress and novel solutions in artificial intelligence. This book aims at presenting the research results and solutions of applications in relevance with artificial intelligence technologies. We propose to researchers and practitioners some methods to advance the intelligent systems and apply artificial intelligence to specific or general purpose. This book consists of 13 contributions that feature fuzzy (r, s)-minimal pre- and β-open sets, handling big coocurrence matrices, Xie-Beni-type fuzzy cluster validation, fuzzy c-regression models, combination of genetic algorithm and ant colony optimization, building expert system, fuzzy logic and neural network, ind...

  10. Sclerotherapy for Reticular Veins in the Lower Limbs: A Triple-Blind Randomized Clinical Trial.

    Science.gov (United States)

    Bertanha, Matheus; Jaldin, Rodrigo Gibin; Moura, Regina; Pimenta, Rafael Elias Farres; Mariúba, Jamil Victor de Oliveira; Lúcio Filho, Carlos Eduardo Pinheiro; Alcantara, Giovana Piteri; Padovani, Carlos Roberto; Yoshida, Winston Bonetti; Sobreira, Marcone Lima

    2017-12-01

    Reticular veins are subdermal veins located in the lower limbs and are mainly associated with aesthetic complaints. Although sclerotherapy is the treatment of choice for reticular veins in the lower limbs, no consensus has been reached regarding to the optimal sclerosant. To compare the efficacy and safety of 2 sclerosants used to treat reticular veins: 0.2% polidocanol diluted in 70% hypertonic glucose (HG) (group 1) vs 75% HG alone (group 2). Prospective, randomized, triple-blind, controlled, parallel-group clinical trial with patients randomly assigned in a 1:1 ratio between the 2 treatment groups from March through December 2014, with 2 months' follow-up. The study was conducted in a single academic medical center. Eligible participants were all women, aged 18 to 69 years, who had at least 1 reticular vein with a minimum length of 10 cm in 1 of their lower limbs. The patients underwent sclerotherapy in a single intervention with either 0.2% polidocanol plus 70% HG or 75% HG alone to eliminate reticular veins. The primary efficacy end point was the disappearance of the reticular veins within 60 days after treatment with sclerotherapy. The reticular veins were measured on images obtained before treatment and after treatment using ImageJ software. Safety outcomes were analyzed immediately after treatment and 7 days and 60 days after treatment and included serious adverse events (eg, deep vein thrombosis and systemic complications) and minor adverse events (eg, pigmentation, edema, telangiectatic matting, and hematomas). Ninety-three women completed the study, median (interquartile range) age 43.0 (24.0-61.0) years for group 1 and 41.0 (27.0-62.0) years for group 2. Sclerotherapy with 0.2% polidocanol plus 70% HG was significantly more effective than with 75% HG alone in eliminating reticular veins from the treated area (95.17% vs 85.40%; P vein pigmentation length for group 1 and 7.09% for group 2, with no significant difference between the groups (P = .09

  11. Finger Vein Recognition Based on Personalized Weight Maps

    Science.gov (United States)

    Yang, Gongping; Xiao, Rongyang; Yin, Yilong; Yang, Lu

    2013-01-01

    Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs). The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition. PMID:24025556

  12. Finger Vein Recognition Based on Personalized Weight Maps

    Directory of Open Access Journals (Sweden)

    Lu Yang

    2013-09-01

    Full Text Available Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs. The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition.

  13. Deep Vein Thrombosis

    Centers for Disease Control (CDC) Podcasts

    2012-04-05

    This podcast discusses the risk for deep vein thrombosis in long-distance travelers and ways to minimize that risk.  Created: 4/5/2012 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 4/5/2012.

  14. Characterization of a porcine model of chronic superficial varicose veins.

    Science.gov (United States)

    Jones, Gregory T; Grant, Mark W; Thomson, Ian A; Hill, B Geraldine; van Rij, André M

    2009-06-01

    Previous animal models of venous disease, while inducing venous hypertension and valvular insufficiency, do not produce superficial varicose veins. In this study, we aimed to develop and characterize a pig-based model of superficial varicose veins. Right femoral arteriovenous fistulae (AVF) were surgically fashioned in young adult pigs. Animals were examined at postoperative times up to 15 weeks to determine the development of varicose veins and measurement of both blood pressure and flow velocities within the superficial thigh veins. Histology and vascular corrosion casts were used to characterize the resulting structural venous alterations. Porcine pathophysiological features were compared with those of human primary superficial varicose veins. Gross superficial varicosities developed over the ipsilateral medial thigh region after an initial lag period of 1-2 weeks. Veins demonstrated retrograde filling with valvular incompetence, and a moderate, non-pulsatile, venous hypertension, which was altered by changes in posture and Valsalva. Venous blood flow velocities were elevated to 15-30 cm/s in varicose veins. Structurally, pig varicose veins were enlarged, tortuous, had valvular degeneration, and regions of focal medial atrophy with or without overlying intimal thickening. The superficial varicose veins, which developed within this model, have a pathophysiology that is consistent with that observed in humans. The porcine femoral AVF model is proposed as a suitable experimental model to evaluate the pathobiology of superficial venous disease. It may also be suitable for the evaluation of treatment interventions including drug therapy.

  15. [Portal perfusion with right gastroepiploic vein flow in liver transplant].

    Science.gov (United States)

    Mendoza-Sánchez, Federico; Javier-Haro, Francisco; Mendoza-Medina, Diego Federico; González-Ojeda, Alejandro; Cortés-Lares, José Antonio; Fuentes-Orozco, Clotilde

    Liver transplantation in patients with liver cirrhosis, portal vein thrombosis, and cavernous transformation of the portal vein, is a complex procedure with high possibility of liver graft dysfunction. It is performed in 2-19% of all liver transplants, and has a significantly high mortality rate in the post-operative period. Other procedures to maintain portal perfusion have been described, however there are no reports of liver graft perfusion using right gastroepiploic vein. A 20 year-old female diagnosed with cryptogenic cirrhosis, with a Child-Pugh score of 7 points (class "B"), and MELD score of 14 points, with thrombosis and cavernous transformation of the portal vein, severe portal hypertension, splenomegaly, a history of upper gastrointestinal bleeding due to oesophageal varices, and left renal agenesis. The preoperative evaluation for liver transplantation was completed, and the right gastroepiploic vein of 1-cm diameter was observed draining to the infrahepatic inferior vena cava and right suprarenal vein. An orthotopic liver transplantation was performed from a non-living donor (deceased on January 30, 2005) using the Piggy-Back technique. Portal vein perfusion was maintained using the right gastroepiploic vein, and the outcome was satisfactory. The patient was discharged 13 days after surgery. Liver transplantation was performed satisfactorily, obtaining an acceptable outcome. In this case, the portal perfusion had adequate blood flow through the right gastroepiploic vein. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  16. A study of images of Projective Angles of pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Wang Jue [Beijing Anzhen Hospital, Beijing (China); Zhaoqi, Zhang [Beijing Anzhen Hospital, Beijing (China)], E-mail: zhaoqi5000@vip.sohu.com; Yu Wei; Miao Cuilian; Yan Zixu; Zhao Yike [Beijing Anzhen Hospital, Beijing (China)

    2009-09-15

    Aims: In images of magnetic resonance and computed tomography (CT) there are visible angles between pulmonary veins and the coronary, transversal or sagittal section of body. In this study these angles are measured and defined as Projective Angles of pulmonary veins. Several possible influential factors and characters of distribution are studied and analyzed for a better understanding of this imaging anatomic character of pulmonary veins. And it could be the anatomic base of adjusting correctly the angle of the central X-ray of the angiography of pulmonary veins undergoing the catheter ablation of atrial fibrillation (AF). Method: Images of contrast enhanced magnetic resonance angiography (CEMRA) and contrast enhanced computer tomography (CECT) of the left atrium and pulmonary veins of 137 health objects and patients with atrial fibrillation (AF) are processed with the technique of post-processing, and Projective Angles to the coronary and transversal sections are measured and analyzed statistically. Result: Project Angles of pulmonary veins are one of real and steady imaging anatomic characteristics of pulmonary veins. The statistical distribution of variables is relatively concentrated, with a fairly good representation of average value. It is possible to improve the angle of the central X-ray according to the average value in the selective angiography of pulmonary veins undergoing the catheter ablation of AF.

  17. Hydrothermal uranium vein deposits in Marysvale volcanic field, Utah

    International Nuclear Information System (INIS)

    Rasmussen, J.D.; Cunningham, C.G.; Steven, T.A.; Rye, R.O.; Romberger, S.B.

    1984-01-01

    Hydrothermal uranium veins are exposed over a 300 m (980 ft) vertical range in mines of the Central Mining area, near Marysvale, Utah. They cut 23 Ma quartz monzonite, 21 Ma granite, and 19 Ma rhyolite ash-flow tuff. The veins formed 18-19 Ma, in an area 1 km (0.6 mi) across, above the center of a composite magma chamber at least 12 x 6 km across that fed a sequence of 21-14 Ma hypabyssal granitic stocks, and rhyolitic lava flows, ash-flow tuffs, and volcanic domes. Intrusive pressure uplifted and fractured the roof; molybdenite-bearing, uranium-rich glassy dikes were intruded; and a breccia pipe and uranium-bearing veins were formed. The veins appear to have been deposited near the surface above a concealed rhyolite stock, where they filled high-angle fault zones and flat-lying to concave-downward pull-apart fractures. Low pH and fO 2 hydrothermal fluids at temperatures near 200 0 C (392 0 F) permeated the fractured rocks; these fluids were rich in fluorine and potassium, and contained uranium as uranous-fluoride complexes. Fluid-wall rock interaction increased fluid pH, causing precipitation of uranium minerals. At the deepest exposed levels, wall rocks were altered to kaolinite and sericite, and uraninite, coffinite, jordisite, fluorite, molybdenite, quartz, and pyrite (with delta 34 S near zero per mil) were deposited. The fluids were progressively oxidized higher in the system; iron in the wall rocks was oxidized to hematite, and sooty uraninite and umohoite were deposited

  18. Adrenal vein catheterization. Anatomic considerations

    Energy Technology Data Exchange (ETDEWEB)

    El-Sherief, M.A. (Akademiska Sjukhuset, Uppsala (Sweden))

    1982-01-01

    Twenty post-mortem specimens and 93 phlebographies (56 right side, 37 left side) from 44 patients were investigated with respect to the adrenal venous anatomy. At autopsy, the venous orifices displayed in the area of adrenal drainage were injected bilaterally to identify the adrenal vein(s), the surrounding channels and the presence of interconnections. The findings were correlated with those at clinical phlebography, and the different sources of error were elicited. These were mainly found on the right side. Some guidelines are suggested in the hope that these will contribute to eliminate misconceptions.

  19. [Energy and memory efficient calculation of the accommodation demand in the artificial accommodation system].

    Science.gov (United States)

    Nagel, J A; Beck, C; Harms, H; Stiller, P; Guth, H; Stachs, O; Bretthauer, G

    2010-12-01

    Presbyopia and cataract are gaining more and more importance in the ageing society. Both age-related complaints are accompanied with a loss of the eye's ability to accommodate. A new approach to restore accommodation is the Artificial Accommodation System, an autonomous micro system, which will be implanted into the capsular bag instead of a rigid intraocular lens. The Artificial Accommodation System will, depending on the actual demand for accommodation, autonomously adapt the refractive power of its integrated optical element. One possibility to measure the demand for accommodation non-intrusively is to analyse eye movements. We present an efficient algorithm, based on the CORDIC technique, to calculate the demand for accommodation from magnetic field sensor data. It can be shown that specialised algorithms significantly shorten calculation time without violating precision requirements. Additionally, a communication strategy for the wireless exchange of sensor data between the implants of the left and right eye is introduced. The strategy allows for a one-sided calculation of the demand for accommodation, resulting in an overall reduction of calculation time by 50 %. The presented methods enable autonomous microsystems, such as the Artificial Accommodation System, to save significant amounts of energy, leading to extended autonomous run-times. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Vein-type uranium deposits

    International Nuclear Information System (INIS)

    Rich, R.A.; Holland, H.D.; Petersen, U.

    1975-01-01

    A critical review is presented of published data bearing on the mineralogy, paragenesis, geochemistry, and origin of veiw-type uranium deposits. Its aim is to serve as a starting point for new research and as a basis for the development of new exploration strategies. During the formation of both vein and sandstone types of deposits uranium seems to have been dissolved by and transported in rather oxidized solutions, and deposited where these solutions encountered reducing agents such as carbon, sulfides, ferrous minerals and hydrocarbons. Granitic rocks abnormally enriched in uranium have apparently been the most common source for uranium in vein-type deposits. Oxidizing solutions have been derived either from the surface or from depth. Surface solutions saturated with atmospheric oxygen have frequently passed through red bed or clean sandstone conduits on their way to and from uranium source rocks. Deep solutions of non-surface origin have apparently become sufficiently oxidizing by passage through and equilibration with red beds. The common association of clean sandstones or red beds with uranium-rich granites in the vicinity of vein-type uranium deposits is probably not fortuitous, and areas where these rock types are found together are considered particularly favorable targets for uranium exploration

  1. Interposition vein cuffs.

    Science.gov (United States)

    Harris, P; Da Silva, T; How, T

    1996-01-01

    A vein cuff interposed at the distal anastomosis between a prosthetic vascular graft and a recipient infrageniculate artery improves the chances of continued patency of the graft, at least in the short and medium term. The mode of effect appears to be suppression or modification of anastomotic myointimal hyperplasia (MIH). In the event of graft failure the recipient artery and run-off vessels remain free from MIH and their patency is preserved thereby improving the prospects for further vascular reconstruction and limb salvage. The mechanisms by which interposition vein cuffs might modulate MIH are reviewed. Experimental evidence is described to show that the geometry of a cuffed anastomosis promotes a characteristic haemodynamic flow structure with a stable vortex. It is suggested that this vortex exerts greater shear stress upon the wall of the artery than the normal laminar flow observed in conventional anastomoses. High shear stress is known to inhibit MIH.

  2. Influence of the Mechanical Properties of Third-Generation Artificial Turf Systems on Soccer Players’ Physiological and Physical Performance and Their Perceptions

    Science.gov (United States)

    Sánchez-Sánchez, Javier; García-Unanue, Jorge; Jiménez-Reyes, Pedro; Gallardo, Ana; Burillo, Pablo; Felipe, José Luis; Gallardo, Leonor

    2014-01-01

    The aim of this research was to evaluate the influence of the mechanical properties of artificial turf systems on soccer players’ performance. A battery of perceptive physiological and physical tests were developed on four different structural systems of artificial turf (System 1: Compacted gravel sub-base without elastic layer; System 2: Compacted gravel sub-base with elastic layer; System 3: Asphalt sub-base without elastic layer; System 4: Asphalt sub-base with elastic layer). The sample was composed of 18 soccer players (22.44±1.72 years) who typically train and compete on artificial turf. The artificial turf system with less rotational traction (S3) showed higher total time in the Repeated Sprint Ability test in comparison to the systems with intermediate values (49.46±1.75 s vs 47.55±1.82 s (S1) and 47.85±1.59 s (S2); pperformance in jumping tests (countermovement jump and squat jump) and ball kicking to goal decreased after the RSA test in all surfaces assessed (pperformance deterioration (p>0.05). The physiological load was similar in all four artificial turf systems. However, players felt more comfortable on the harder and more rigid system (S4; visual analogue scale = 70.83±14.28) than on the softer artificial turf system (S2; visual analogue scale = 54.24±19.63). The lineal regression analysis revealed a significant influence of the mechanical properties of the surface of 16.5%, 15.8% and 7.1% on the mean time of the sprint, the best sprint time and the maximum mean speed in the RSA test respectively. Results suggest a mechanical heterogeneity between the systems of artificial turf which generate differences in the physical performance and in the soccer players’ perceptions. PMID:25354188

  3. Hemodynamic evaluation of the right portal vein in healthy dogs of different body weights

    Directory of Open Access Journals (Sweden)

    de Almeida Mariana F

    2010-05-01

    Full Text Available Abstract Background Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights. Methods Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography. Results In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values. Conclusion Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.

  4. Learning modalities in artificial intelligence systems: a framework and review

    Energy Technology Data Exchange (ETDEWEB)

    Araya, A A

    1982-01-01

    Intelligent systems should possess two fundamental capabilities: problem solving and learning. Problem solving capabilities allow an intelligent system to cope with problems in a given domain. Learning capabilities make possible for an intelligent system to improve the solution to the problems within its current reach or to cope with new problems. This paper examines research in artificial intelligence from the perspective of learning with the purpose of: 1) developing and understanding of the problem of learning from the AI point of view, and II) characterizing the current state of the art on learning in AI. 35 references.

  5. The design and fabrication of two portal vein flow phantoms by different methods

    Energy Technology Data Exchange (ETDEWEB)

    Yunker, Bryan E., E-mail: bryan.yunker@ucdenver.edu; Lanning, Craig J.; Shandas, Robin; Hunter, Kendall S. [Department of Bioengineering, University of Colorado – Denver/Anschutz, 12700 East 19th Avenue, MS 8607, Aurora, Colorado 80045 (United States); Dodd, Gerald D., E-mail: gerald.dodd@ucdenver.edu; Chang, Samuel; Scherzinger, Ann L. [Department of Radiology, University of Colorado – SOM, 12401 East 17th Avenue, Mail Stop L954, Aurora, Colorado 80045 (United States); Chen, S. James, E-mail: james.chen@ucdenver.edu [Department of Medicine, University of Colorado Denver, Colorado 80045 and Department of Medicine/Cardiology, University of Colorado – SOM, 12401 East 17th Avenue, Mail Stop B132, Aurora, Colorado 80045 (United States); Feng, Yusheng, E-mail: yusheng.feng@utsa.edu [Department of Mechanical Engineering, University of Texas – San Antonio, One UTSA Circle, Mail Stop: AET 2.332, San Antonio, Texas 78249–0670 (United States)

    2014-02-15

    Purpose: This study outlines the design and fabrication techniques for two portal vein flow phantoms. Methods: A materials study was performed as a precursor to this phantom fabrication effort and the desired material properties are restated for continuity. A three-dimensional portal vein pattern was created from the Visual Human database. The portal vein pattern was used to fabricate two flow phantoms by different methods with identical interior surface geometry using computer aided design software tools and rapid prototyping techniques. One portal flow phantom was fabricated within a solid block of clear silicone for use on a table with Ultrasound or within medical imaging systems such as MRI, CT, PET, or SPECT. The other portal flow phantom was fabricated as a thin walled tubular latex structure for use in water tanks with Ultrasound imaging. Both phantoms were evaluated for usability and durability. Results: Both phantoms were fabricated successfully and passed durability criteria for flow testing in the next project phase. Conclusions: The fabrication methods and materials employed for the study yielded durable portal vein phantoms.

  6. Internal jugular vein: Peripheral vein adrenocorticotropic hormone ratio in patients with adrenocorticotropic hormone-dependent Cushing′s syndrome: Ratio calculated from one adrenocorticotropic hormone sample each from right and left internal jugular vein during corticotrophin releasing hormone stimulation test

    Directory of Open Access Journals (Sweden)

    Sachin Chittawar

    2013-01-01

    Full Text Available Background: Demonstration of central: Peripheral adrenocorticotropic hormone (ACTH gradient is important for diagnosis of Cushing′s disease. Aim: The aim was to assess the utility of internal jugular vein (IJV: Peripheral vein ACTH ratio for diagnosis of Cushing′s disease. Materials and Methods: Patients with ACTH-dependent Cushing′s syndrome (CS patients were the subjects for this study. One blood sample each was collected from right and left IJV following intravenous hCRH at 3 and 5 min, respectively. A simultaneous peripheral vein sample was also collected with each IJV sample for calculation of IJV: Peripheral vein ACTH ratio. IJV sample collection was done under ultrasound guidance. ACTH was assayed using electrochemiluminescence immunoassay (ECLIA. Results: Thirty-two patients participated in this study. The IJV: Peripheral vein ACTH ratio ranged from 1.07 to 6.99 ( n = 32. It was more than 1.6 in 23 patients. Cushing′s disease could be confirmed in 20 of the 23 cases with IJV: Peripheral vein ratio more than 1.6. Four patients with Cushing′s disease and 2 patients with ectopic ACTH syndrome had IJV: Peripheral vein ACTH ratio less than 1.6. Six cases with unknown ACTH source were excluded for calculation of sensitivity and specificity of the test. Conclusion: IJV: Peripheral vein ACTH ratio calculated from a single sample from each IJV obtained after hCRH had 83% sensitivity and 100% specificity for diagnosis of CD.

  7. The vein collar

    DEFF Research Database (Denmark)

    Lundgren, F; Schroeder, Torben Veith

    2012-01-01

    Randomized studies evaluating the effect of a vein collar at the distal anastomosis of PTFE-grafts show conflicting results. The study of the Joint Vascular Research Group (JVRG) of UK found improved primary patency while the Scandinavian Miller Collar Study (SCAMICOS) found neither any effect...

  8. Mesenteric vein thrombosis after percitaneous transhepatic portal vein catheterisation for the localisation of an insulinoma

    International Nuclear Information System (INIS)

    Luska, G.; Langer, H.E.; Le Blanc, S.; Medizinische Hochschule Hannover

    1984-01-01

    The authors report on a fatal mesenteric vein thrombosis following an uncomplicated percutaneous transhepatic portal vein catheterisation for the localisation of an insulinoma. Several hours after the procedure the patient developed an acute abdomen. An emergency laparotomy revealed a haemorrhagic infarct of the ileum. The resected specimen showed an acute phlebitis with fresh thrombus. The cause of the phlebothrombosis was thought to be intimal damage from high osmolar contrast medium. There was no evidence of damage due to the catheder, either on the phlebogram or pathologically. (orig.) [de

  9. Overload control of artificial gravity facility using spinning tether system for high eccentricity transfer orbits

    Science.gov (United States)

    Gou, Xing-wang; Li, Ai-jun; Tian, Hao-chang; Wang, Chang-qing; Lu, Hong-shi

    2018-06-01

    As the major part of space life supporting systems, artificial gravity requires further study before it becomes mature. Spinning tether system is a good alternative solution to provide artificial gravity for the whole spacecraft other than additional devices, and its longer tether length could significantly reduce spinning velocity and thus enhance comfortability. An approximated overload-based feedback method is proposed to provide estimated spinning velocity signals for controller, so that gravity level could be accurately controlled without complicated GPS modules. System behavior in high eccentricity transfer orbits is also studied to give a complete knowledge of the spinning stabilities. The application range of the proposed method is studied in various orbit cases and spinning velocities, indicating that it is accurate and reliable for most of the mission phases especially for the final constant gravity level phase. In order to provide stable gravity level for transfer orbit missions, a sliding mode controller based on estimated angular signals is designed for closed-loop control. Numerical results indicate that the combination of overload-based feedback and sliding mode controller could satisfy most of the long-term artificial gravity missions. It is capable of forming flexible gravity environment in relatively good accuracy even in the lowest possible orbital radiuses and high eccentricity orbits of crewed space missions. The proposed scheme provides an effective tether solution for the artificial gravity construction in interstellar travel.

  10. Incidental retroaortic left innominate vein in adult patient

    Directory of Open Access Journals (Sweden)

    Alexandre Semionov, MD, PhD

    2017-09-01

    Full Text Available Retro-aortic left innominate vein is a rare vascular abnormality, usually associated with congenital heart disease. Here we report a case of isolated retro-aortic left innominate vein in an adult female.

  11. A photocatalyst-enzyme coupled artificial photosynthesis system for solar energy in production of formic acid from CO2.

    Science.gov (United States)

    Yadav, Rajesh K; Baeg, Jin-Ook; Oh, Gyu Hwan; Park, No-Joong; Kong, Ki-jeong; Kim, Jinheung; Hwang, Dong Won; Biswas, Soumya K

    2012-07-18

    The photocatalyst-enzyme coupled system for artificial photosynthesis process is one of the most promising methods of solar energy conversion for the synthesis of organic chemicals or fuel. Here we report the synthesis of a novel graphene-based visible light active photocatalyst which covalently bonded the chromophore, such as multianthraquinone substituted porphyrin with the chemically converted graphene as a photocatalyst of the artificial photosynthesis system for an efficient photosynthetic production of formic acid from CO(2). The results not only show a benchmark example of the graphene-based material used as a photocatalyst in general artificial photosynthesis but also the benchmark example of the selective production system of solar chemicals/solar fuel directly from CO(2).

  12. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    Science.gov (United States)

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access

  13. Intravitreal triamcinolone acetonide injections in the treatment of retinal vein occlusions.

    Science.gov (United States)

    Roth, Daniel B; Cukras, Catherine; Radhakrishnan, Ravi; Feuer, William J; Yarian, David L; Green, Stuart N; Wheatley, Harold M; Prenner, Jonathan

    2008-01-01

    To report the visual acuity response after intravitreal triamcinolone injection in patients with macular edema due to retinal vein occlusions. Retrospective nonrandomized interventional series of 172 consecutive patients with macular edema due to retinal vein occlusions who were treated with intravitreal triamcinolone acetonide injection. Patients underwent Snellen visual acuity testing and ophthalmoscopic examination at baseline and 1, 3, 6, and 12 months after intravitreal triamcinolone acetonide injection. All subtypes of retinal vein occlusions showed significant improvements in mean visual acuity 1 month after injection. This improvement in visual acuity was maintained over the 12-month period for all but the central retinal vein occlusion group. Seventy-one (41.3%) of the 172 patients received more than one intravitreal triamcinolone injection for unresolved or recurrent macular edema. This study demonstrates a benefit associated with intravitreal triamcinolone acetonide injection for retinal vein occlusions that was maintained by patients with branch retinal vein occlusions and hemiretinal vein occlusions over a 12-month period. Visual acuity improvement was not maintained in patients with central retinal vein occlusions with this course of treatment.

  14. The portal vein in children: radiological review of congenital anomalies and acquired abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Corness, Jonathan A.G.; McHugh, Kieran; Roebuck, Derek J. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Taylor, Andrew M. [Institute of Child Health, Cardiothoracic Unit, London (United Kingdom)

    2006-02-01

    A variety of portal vein anomalies that occur in children can be identified by US, CT, MRI and portal venography. Although these abnormalities can also occur in adults, there are certain pathological processes and aberrations within the portal system that are specific to children. Knowledge of the embryology and anatomy of the portal vein is of benefit in the understanding of these anomalies. Identifying deviations from normal portal architecture is important in the work-up for surgery such as liver transplantation, and prior to interventional procedures such as stent placement or embolization. The aim of this paper is to summarize the various types of congenital and acquired portal vein abnormalities that occur in children, describe their radiological features and provide images to demonstrate the differences from normal portal venous anatomy. (orig.)

  15. The portal vein in children: radiological review of congenital anomalies and acquired abnormalities

    International Nuclear Information System (INIS)

    Corness, Jonathan A.G.; McHugh, Kieran; Roebuck, Derek J.; Taylor, Andrew M.

    2006-01-01

    A variety of portal vein anomalies that occur in children can be identified by US, CT, MRI and portal venography. Although these abnormalities can also occur in adults, there are certain pathological processes and aberrations within the portal system that are specific to children. Knowledge of the embryology and anatomy of the portal vein is of benefit in the understanding of these anomalies. Identifying deviations from normal portal architecture is important in the work-up for surgery such as liver transplantation, and prior to interventional procedures such as stent placement or embolization. The aim of this paper is to summarize the various types of congenital and acquired portal vein abnormalities that occur in children, describe their radiological features and provide images to demonstrate the differences from normal portal venous anatomy. (orig.)

  16. Artificial intelligence in the service of system administrators

    Science.gov (United States)

    Haen, C.; Barra, V.; Bonaccorsi, E.; Neufeld, N.

    2012-12-01

    The LHCb online system relies on a large and heterogeneous IT infrastructure made from thousands of servers on which many different applications are running. They run a great variety of tasks: critical ones such as data taking and secondary ones like web servers. The administration of such a system and making sure it is working properly represents a very important workload for the small expert-operator team. Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called “self objectives” supposed to lead to “autonomic computing”. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with an “object oriented paradigm” architecture should increase our learning speed a lot and highlight relations between problems.

  17. Symptom based diagnostic system using artificial neural networks

    International Nuclear Information System (INIS)

    Santosh; Vinod, Gopika; Saraf, R.K.

    2003-01-01

    Nuclear power plant experiences a number of transients during its operations. In case of such an undesired plant condition generally known as an initiating event, the operator has to carry out diagnostic and corrective actions. The operator's response may be too late to mitigate or minimize the negative consequences in such scenarios. The objective of this work is to develop an operator support system based on artificial neural networks that will assist the operator to identify the initiating events at the earliest stages of their developments. A symptom based diagnostic system has been developed to investigate the initiating events. Neutral networks are utilized for carrying out the event identification by continuously monitoring process parameters. Whenever an event is detected, the system will display the necessary operator actions along with the initiating event. The system will also show the graphical trend of process parameters that are relevant to the event. This paper describes the features of the software that is used to monitor the reactor. (author)

  18. Artificial intelligence in the service of system administrators

    International Nuclear Information System (INIS)

    Haen, C; Barra, V; Bonaccorsi, E; Neufeld, N

    2012-01-01

    The LHCb online system relies on a large and heterogeneous IT infrastructure made from thousands of servers on which many different applications are running. They run a great variety of tasks: critical ones such as data taking and secondary ones like web servers. The administration of such a system and making sure it is working properly represents a very important workload for the small expert-operator team. Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called “self objectives” supposed to lead to “autonomic computing”. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with an “object oriented paradigm” architecture should increase our learning speed a lot and highlight relations between problems.

  19. Fault tolerant architecture for artificial olfactory system

    International Nuclear Information System (INIS)

    Lotfivand, Nasser; Hamidon, Mohd Nizar; Abdolzadeh, Vida

    2015-01-01

    In this paper, to cover and mask the faults that occur in the sensing unit of an artificial olfactory system, a novel architecture is offered. The proposed architecture is able to tolerate failures in the sensors of the array and the faults that occur are masked. The proposed architecture for extracting the correct results from the output of the sensors can provide the quality of service for generated data from the sensor array. The results of various evaluations and analysis proved that the proposed architecture has acceptable performance in comparison with the classic form of the sensor array in gas identification. According to the results, achieving a high odor discrimination based on the suggested architecture is possible. (paper)

  20. FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

    Directory of Open Access Journals (Sweden)

    Canh Nguyen

    2015-01-01

    Full Text Available Objective(s: In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT, complicating hepatocellular carcinoma (HCC in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT, which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%. PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001. FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001. PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6% had no extrahepatic metastasis, 3 cases (33.3% had metastasis of regional lymph nodes, and 1 case (11.1% presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are

  1. Contact-free palm-vein recognition based on local invariant features.

    Directory of Open Access Journals (Sweden)

    Wenxiong Kang

    Full Text Available Contact-free palm-vein recognition is one of the most challenging and promising areas in hand biometrics. In view of the existing problems in contact-free palm-vein imaging, including projection transformation, uneven illumination and difficulty in extracting exact ROIs, this paper presents a novel recognition approach for contact-free palm-vein recognition that performs feature extraction and matching on all vein textures distributed over the palm surface, including finger veins and palm veins, to minimize the loss of feature information. First, a hierarchical enhancement algorithm, which combines a DOG filter and histogram equalization, is adopted to alleviate uneven illumination and to highlight vein textures. Second, RootSIFT, a more stable local invariant feature extraction method in comparison to SIFT, is adopted to overcome the projection transformation in contact-free mode. Subsequently, a novel hierarchical mismatching removal algorithm based on neighborhood searching and LBP histograms is adopted to improve the accuracy of feature matching. Finally, we rigorously evaluated the proposed approach using two different databases and obtained 0.996% and 3.112% Equal Error Rates (EERs, respectively, which demonstrate the effectiveness of the proposed approach.

  2. Contact-free palm-vein recognition based on local invariant features.

    Science.gov (United States)

    Kang, Wenxiong; Liu, Yang; Wu, Qiuxia; Yue, Xishun

    2014-01-01

    Contact-free palm-vein recognition is one of the most challenging and promising areas in hand biometrics. In view of the existing problems in contact-free palm-vein imaging, including projection transformation, uneven illumination and difficulty in extracting exact ROIs, this paper presents a novel recognition approach for contact-free palm-vein recognition that performs feature extraction and matching on all vein textures distributed over the palm surface, including finger veins and palm veins, to minimize the loss of feature information. First, a hierarchical enhancement algorithm, which combines a DOG filter and histogram equalization, is adopted to alleviate uneven illumination and to highlight vein textures. Second, RootSIFT, a more stable local invariant feature extraction method in comparison to SIFT, is adopted to overcome the projection transformation in contact-free mode. Subsequently, a novel hierarchical mismatching removal algorithm based on neighborhood searching and LBP histograms is adopted to improve the accuracy of feature matching. Finally, we rigorously evaluated the proposed approach using two different databases and obtained 0.996% and 3.112% Equal Error Rates (EERs), respectively, which demonstrate the effectiveness of the proposed approach.

  3. A Red-Light Running Prevention System Based on Artificial Neural Network and Vehicle Trajectory Data

    Directory of Open Access Journals (Sweden)

    Pengfei Li

    2014-01-01

    Full Text Available The high frequency of red-light running and complex driving behaviors at the yellow onset at intersections cannot be explained solely by the dilemma zone and vehicle kinematics. In this paper, the author presented a red-light running prevention system which was based on artificial neural networks (ANNs to approximate the complex driver behaviors during yellow and all-red clearance and serve as the basis of an innovative red-light running prevention system. The artificial neural network and vehicle trajectory are applied to identify the potential red-light runners. The ANN training time was also acceptable and its predicting accurate rate was over 80%. Lastly, a prototype red-light running prevention system with the trained ANN model was described. This new system can be directly retrofitted into the existing traffic signal systems.

  4. A red-light running prevention system based on artificial neural network and vehicle trajectory data.

    Science.gov (United States)

    Li, Pengfei; Li, Yan; Guo, Xiucheng

    2014-01-01

    The high frequency of red-light running and complex driving behaviors at the yellow onset at intersections cannot be explained solely by the dilemma zone and vehicle kinematics. In this paper, the author presented a red-light running prevention system which was based on artificial neural networks (ANNs) to approximate the complex driver behaviors during yellow and all-red clearance and serve as the basis of an innovative red-light running prevention system. The artificial neural network and vehicle trajectory are applied to identify the potential red-light runners. The ANN training time was also acceptable and its predicting accurate rate was over 80%. Lastly, a prototype red-light running prevention system with the trained ANN model was described. This new system can be directly retrofitted into the existing traffic signal systems.

  5. A Red-Light Running Prevention System Based on Artificial Neural Network and Vehicle Trajectory Data

    Science.gov (United States)

    Li, Pengfei; Li, Yan; Guo, Xiucheng

    2014-01-01

    The high frequency of red-light running and complex driving behaviors at the yellow onset at intersections cannot be explained solely by the dilemma zone and vehicle kinematics. In this paper, the author presented a red-light running prevention system which was based on artificial neural networks (ANNs) to approximate the complex driver behaviors during yellow and all-red clearance and serve as the basis of an innovative red-light running prevention system. The artificial neural network and vehicle trajectory are applied to identify the potential red-light runners. The ANN training time was also acceptable and its predicting accurate rate was over 80%. Lastly, a prototype red-light running prevention system with the trained ANN model was described. This new system can be directly retrofitted into the existing traffic signal systems. PMID:25435870

  6. Budd-Chiari and inferior caval vein syndromes due to membranous obstruction of the liver veins. Successful treatment with angioplasty and transcaval TIPS

    DEFF Research Database (Denmark)

    Holland-Fischer, Peter

    2004-01-01

    The case is presented of a 25-year-old Caucasian patient with Budd-Chiari syndrome due to membranous obstruction of the liver veins and inferior caval vein syndrome as a result of secondary hyperplasia of the caudate lobe of the liver, obstructing the caval vein. Diagnosis was established...... that angioplasty and TIPS are safe and efficient procedures to reduce liver engorgement and complications of portal hypertension in selected patients with Budd-Chiari syndrome....

  7. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    Science.gov (United States)

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  8. Retinal vein occlusion: pathophysiology and treatment options

    OpenAIRE

    Karia, Niral

    2010-01-01

    Niral KariaDepartment of Ophthalmology, Southend Hospital, Prittlewell Chase, Westcliff on Sea, Essex, United KingdomAbstract: This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms.Keywords: central, hemispheric, branch, retinal vein occlusion, visual loss

  9. Artefact: the division of artificial intelligence, robotics and expert systems

    Energy Technology Data Exchange (ETDEWEB)

    Ferber, J

    1983-06-01

    The history of artificial intelligence is traced from its beginnings in 1956 to its current coverage of the areas of problem-solving, expert systems and games, natural-language processing, robotics, picture and speech recognition, automatic programming, and computer-aided design and instruction. Each area is reviewed in turn, programming languages and techniques are discussed, and both apocalyptic forecasts and underestimates of future developments are criticised.

  10. Percutaneous closure of patent ductus arteriosus in interrupted inferior caval vein through femoral vein approach

    Directory of Open Access Journals (Sweden)

    Endale Tefera

    2014-01-01

    Full Text Available Percutaneous closure of the patent arterial duct in patients with interrupted inferior caval vein poses a technical challenge. A 12-year-old girl with a patent ductus arteriosus (PDA and interrupted inferior caval vein is described in this report. The diagnosis of interrupted inferior caval vein and azygos continuation was made in the catheterization laboratory. A catheter was advanced and snared in the descending aorta. An exchange wire was advanced through the catheter and snared in the descending aorta. Then, an Amplatzer TorqVue 2 delivery sheath was advanced over the wire from the venous side and again snared in the descending aorta. An Amplatzer duct occluder (ADO size 8/6 was advanced through the sheath while still holding the sheath with a snare. The device was opened. The sheath was then unsnared once the aortic disc was completely out. The sheath and the device were pulled back into the duct and the device was successfully implanted. The device was then released and it attained a stable position. An aortic angiogram was performed which showed complete occlusion.

  11. Percutaneous closure of patent ductus arteriosus in interrupted inferior caval vein through femoral vein approach

    International Nuclear Information System (INIS)

    Tefera, Endale; Bermudez-Cañete, Ramon

    2014-01-01

    Percutaneous closure of the patent arterial duct in patients with interrupted inferior caval vein poses a technical challenge. A 12-year-old girl with a patent ductus arteriosus (PDA) and interrupted inferior caval vein is described in this report. The diagnosis of interrupted inferior caval vein and azygos continuation was made in the catheterization laboratory. A catheter was advanced and snared in the descending aorta. An exchange wire was advanced through the catheter and snared in the descending aorta. Then, an Amplatzer TorqVue 2 delivery sheath was advanced over the wire from the venous side and again snared in the descending aorta. An Amplatzer duct occluder (ADO) size 8/6 was advanced through the sheath while still holding the sheath with a snare. The device was opened. The sheath was then unsnared once the aortic disc was completely out. The sheath and the device were pulled back into the duct and the device was successfully implanted. The device was then released and it attained a stable position. An aortic angiogram was performed which showed complete occlusion

  12. [Intraosseous veins of the maxilla in the newborn].

    Science.gov (United States)

    Bogdanov, R A

    1975-12-01

    The intraosseous veins of the maxilla in newborns grow larger with enlargement of the bone and become disposed in three mutually perpendicular planes. The venous plexus of the alveolar process is large. V. v. vallares are thin and interlace forming a network. The veins of interdental septum are well pronounced. The thick venous network of the periosteum and the mucous membrane of the nasal surface of the palatine process includes the vessels transversal and longitudinal to the nasal septum. The venous loops of the incisor part are of triangular, pentagonal and polygonal shape. The veins of the palatine process are connected with 3-4 large vessels falling into the vessels of the tear duct. The transversal and oblique veins of the oral surface of the palatine process are connected with large vessels disposed in parallel to the medial structure of the hard palate. The venous network of the incisor part of the bone is restricted by densified small arc-shaped plexuses. Two-three largest veins lie sagittally and, connected by arc-shaped anastomoses, are tributaries of the vessels of the palate bone, soft palate and pharynx.

  13. Detection of posterior vortex veins in eyes with pathologic myopia by ultra-widefield indocyanine green angiography.

    Science.gov (United States)

    Moriyama, Muka; Cao, Kejia; Ogata, Satoko; Ohno-Matsui, Kyoko

    2017-09-01

    To analyse the characteristics of posterior vortex veins detected in highly myopic eyes by wide-field indocyanine green angiography (ICGA). One hundred and fifty-eight consecutive patients (302 eyes) with high myopia (myopic refractive error >8.0 dioptres (D) or axial length ≥26.5 mm) were studied. Wide-field ICGA was performed with the Spectralis HRA module. Posterior vortex veins were found in 80 eyes (26%). The prevalence of posterior staphyloma was significantly higher in eyes in which posterior vortex vein was detected than in eyes without posterior vortex vein. The posterior vortex veins were classified into five types according to the site of exit from the eye; around the optic nerve in 28%, in the macular area in 17%, along the border of staphyloma in 6%, along the margin of macular atrophy or large peripapillary conus in 21%, and elsewhere in 28%. In one eye, two posterior vortex veins collected the choroidal venous blood from the entire fundus. Wide-field ICGA can analyse the characteristic features of choroidal blood outflow system through posterior vortex veins in highly myopic eyes. They may play an important role as routes of choroidal outflow in highly myopic eyes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Towards Realization of Intelligent Medical Treatment at Nanoscale by Artificial Microscopic Swarm Control Systems

    Directory of Open Access Journals (Sweden)

    Alireza Rowhanimanesh

    2017-07-01

    Full Text Available Background: In this paper, the novel concept of artificial microscopic swarm control systems is proposed as a promising approach towards realization of intelligent medical treatment at nanoscale. In this new paradigm, treatment is done autonomously at nanoscale within the patient’s body by the proposed swarm control systems.Methods: From control engineering perspective, medical treatment can be considered as a control problem, in which the ultimate goal is to find the best feasible way to change the state of diseased tissue from unhealthy to healthy in presence of uncertainty. Although a living tissue is a huge swarm of microscopic cells, nearly all of the common treatment methods are based on macroscopic centralized control paradigm. Inspired by natural microscopic swarm control systems such as nervous, endocrine and immune systems that work based on swarm control paradigm, medical treatment needs a paradigm shift from macroscopic centralized control to microscopic swarm control. An artificial microscopic swarm control system consists of a huge number of very simple autonomous microscopic agents that exploit swarm intelligence to realize sense, control (computing and actuation at nanoscale in local, distributed and decentralized manner. This control system can be designed based on mathematical analysis and computer simulation.Results: The proposed approach is used for treatment of atherosclerosis and cancer based on mathematical analysis and in-silico study.Conclusion: The notion of artificial microscopic swarm control systems opens new doors towards realization of autonomous and intelligent medical treatment at nanoscale within the patient’s body.

  15. Artificial intelligence

    International Nuclear Information System (INIS)

    Perret-Galix, D.

    1992-01-01

    A vivid example of the growing need for frontier physics experiments to make use of frontier technology is in the field of artificial intelligence and related themes. This was reflected in the second international workshop on 'Software Engineering, Artificial Intelligence and Expert Systems in High Energy and Nuclear Physics' which took place from 13-18 January at France Telecom's Agelonde site at La Londe des Maures, Provence. It was the second in a series, the first having been held at Lyon in 1990

  16. Ultrathin Alvarez lens system actuated by artificial muscles.

    Science.gov (United States)

    Petsch, S; Grewe, A; Köbele, L; Sinzinger, S; Zappe, H

    2016-04-01

    A key feature of Alvarez lenses is that they may be tuned in focal length using lateral rather than axial translation, thus reducing the overall length of a focus-tunable optical system. Nevertheless the bulk of classical microsystems actuators limits further miniaturization. We present here a new, ultrathin focus-tunable Alvarez lens fabricated using molding techniques and actuated using liquid crystal elastomer (LCE) artificial muscle actuators. The large deformation generated by the LCE actuators permits the integration of the actuators in-plane with the mechanical and optical system and thus reduces the device thickness to only 1.6 mm. Movement of the Alvarez lens pair of 178 μm results in a focal length change of 3.3 mm, based on an initial focal length of 28.4 mm. This design is of considerable interest for realization of ultraflat focus-tunable and zoom systems.

  17. Learning in Artificial Neural Systems

    Science.gov (United States)

    Matheus, Christopher J.; Hohensee, William E.

    1987-01-01

    This paper presents an overview and analysis of learning in Artificial Neural Systems (ANS's). It begins with a general introduction to neural networks and connectionist approaches to information processing. The basis for learning in ANS's is then described, and compared with classical Machine learning. While similar in some ways, ANS learning deviates from tradition in its dependence on the modification of individual weights to bring about changes in a knowledge representation distributed across connections in a network. This unique form of learning is analyzed from two aspects: the selection of an appropriate network architecture for representing the problem, and the choice of a suitable learning rule capable of reproducing the desired function within the given network. The various network architectures are classified, and then identified with explicit restrictions on the types of functions they are capable of representing. The learning rules, i.e., algorithms that specify how the network weights are modified, are similarly taxonomized, and where possible, the limitations inherent to specific classes of rules are outlined.

  18. Multidetector CT venography and contrast-enhanced MR venography of the inferior mesenteric vein in paediatric extrahepatic portal vein obstruction

    International Nuclear Information System (INIS)

    Chennur, Vikash SrinivasaiahSetty; Sharma, Raju; Gamanagatti, Shivanand; Gupta, Arun Kumar; Bhatnagar, Veereshwar; Vishnubhatla, Sreenivas

    2011-01-01

    Extrahepatic portal vein obstruction (EHPVO) is a common cause of paediatric portal hypertension and the only permanent treatment is shunt surgery. The inferior mesenteric vein (IMV) is a portal venous channel that can be used for the shunt when the splenic vein/superior mesenteric vein is thrombosed or when a lienorenal shunt is not possible. To compare MDCT venography (MDCTV) and contrast-enhanced MR venography (CEMRV) for visualisation of the IMV in children with EHPVO. This was a prospective study of 26 children (4-12 years, median 10 years) who underwent MDCTV and CEMRV. The IMV visualisation was graded using 4- and 2-point scales and the difference in visualisation was assessed by calculating the exact significance probability (P). The IMV was visualised in all children on MDCTV and 25/26 children on CEMRV (96%). The images were diagnostic in 23/26 children (88%) on MDCTV and in 18/26 (69%) children on CEMRV (P = 0.063). MDCTV and CEMRV are comparable for IMV visualisation with a tendency toward MDCTV being superior. (orig.)

  19. Multidetector CT venography and contrast-enhanced MR venography of the inferior mesenteric vein in paediatric extrahepatic portal vein obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Chennur, Vikash SrinivasaiahSetty; Sharma, Raju; Gamanagatti, Shivanand; Gupta, Arun Kumar [All India Institute of Medical Sciences (AIIMS), Department of Radiology, New Delhi (India); Bhatnagar, Veereshwar [AIIMS, Department of Paediatric Surgery, New Delhi (India); Vishnubhatla, Sreenivas [AIIMS, Department of Biostatistics, New Delhi (India)

    2011-03-15

    Extrahepatic portal vein obstruction (EHPVO) is a common cause of paediatric portal hypertension and the only permanent treatment is shunt surgery. The inferior mesenteric vein (IMV) is a portal venous channel that can be used for the shunt when the splenic vein/superior mesenteric vein is thrombosed or when a lienorenal shunt is not possible. To compare MDCT venography (MDCTV) and contrast-enhanced MR venography (CEMRV) for visualisation of the IMV in children with EHPVO. This was a prospective study of 26 children (4-12 years, median 10 years) who underwent MDCTV and CEMRV. The IMV visualisation was graded using 4- and 2-point scales and the difference in visualisation was assessed by calculating the exact significance probability (P). The IMV was visualised in all children on MDCTV and 25/26 children on CEMRV (96%). The images were diagnostic in 23/26 children (88%) on MDCTV and in 18/26 (69%) children on CEMRV (P = 0.063). MDCTV and CEMRV are comparable for IMV visualisation with a tendency toward MDCTV being superior. (orig.)

  20. Primary leiomyosarcoma of the innominate vein.

    Science.gov (United States)

    Illuminati, Giulio; Miraldi, Fabio; Mazzesi, Giuseppe; D'urso, Antonio; Ceccanei, Gianluca; Bezzi, Marcello

    2007-01-01

    Primary venous leiomyosarcoma is rare. We report the case of a primary leiomyosarcoma of the left innominate vein, with neoplastic thrombus extending into the left jugular and subclavian veins. The tumor was curatively resected en bloc with anterior mediastinal and laterocervical lymphatics, through a median sternotomy prolonged into left cervicotomy. Primary venous sarcomas may be associated with prolonged survival in individual cases, with curative resection recommended as the standard treatment, in the absence of distant spread.

  1. Right top pulmonary vein: Evaluation with 64 section multidetector computed tomography

    International Nuclear Information System (INIS)

    Arslan, Gokhan; Dincer, Elvan; Kabaalioglu, Adnan; Ozkaynak, Can

    2008-01-01

    Purpose: To evaluate the incidence and anatomic features of the rare variant of the pulmonary veins named 'right top pulmonary vein' as depicted with 64 section multidetector computed tomography (MDCT). Materials and methods: MDCT of 610 patients obtained over 12 months period for diagnosis of suspected thoracic or cardiac pathology were routinely reviewed in transverse and 3D images. The frequency of right top pulmonary vein (RTPV) was determined and anatomic features were also documented. Results: Right top pulmonary vein (RTPV) is a supernumerary vein arising from the roof of the right part of the left atrium separately from the orifice of the right superior pulmonary vein. It crosses behind the intermediate bronchus and drains mainly posterior segment of the right upper lobe but also receives few subsegmental branches of superior segment of the right lower lobe. It was detected in 2.2% of patients (14/610). The mean diameter of RTPV was 5.1 mm. Conclusion: The RTPV is a rare venous drainage variation of pulmonary veins. It is important to be aware of this anatomic pattern for avoiding misinterpretation of pulmonary venographic findings, inadvertent ablation of pulmonary vein and perioperative bleeding during video assisted thorocoscopic lobectomy

  2. Applications of artificial intelligence systems in the analysis of epidemiological data.

    Science.gov (United States)

    Flouris, Andreas D; Duffy, Jack

    2006-01-01

    A brief review of the germane literature suggests that the use of artificial intelligence (AI) statistical algorithms in epidemiology has been limited. We discuss the advantages and disadvantages of using AI systems in large-scale sets of epidemiological data to extract inherent, formerly unidentified, and potentially valuable patterns that human-driven deductive models may miss.

  3. Portal vein thrombosis after laparoscopic sleeve gastrectomy: presentation and management.

    Science.gov (United States)

    Belnap, LeGrand; Rodgers, George M; Cottam, Daniel; Zaveri, Hinali; Drury, Cara; Surve, Amit

    2016-12-01

    Portal vein thrombosis (PVT) is a serious problem with a high morbidity and mortality, often exceeding 40% of affected patients. Recently, PVT has been reported in patients after laparoscopic sleeve gastrectomy (LSG). The frequency is surprisingly high compared with other abdominal operations. We present a series of 5 patients with PVT after LSG. The treatment was not restricted simply to anticoagulation alone, but was determined by the extent of disease. A distinction is made among nonocclusive, high-grade nonocclusive, and occlusive PVT. We present evidence that systemic anticoagulation is insufficient in occlusive thrombosis and may also be insufficient in high-grade nonocclusive disease. Single private institution, United States. We present a retrospective analysis of 646 patients who underwent LSG between 2012 and 2015. In all patients, the diagnosis was established with an abdominal computed tomography (CT) scan as well as duplex ultrasound of the portal venous system. All patients received systemic anticoagulation. Depending on the extent of disease, thrombolytic therapy and portal vein thrombectomy were utilized. All patients received long-term anticoagulation. Four patients with PVT were identified. A fifth patient with PVT after LSG was referred from another center. The mean age of all patients was 49 years. One patient had a history of deep vein thrombosis (DVT). No complications were identified intraoperatively or during the hospital stay, and all patients were discharged by postoperative day 2. The patients presented with PVT at an average of 20 days (range: 10-35) post-LSG. The CT scan was positive for PVT in all patients. In stable noncirrhotic patients with nonocclusive disease, we administered therapeutic anticoagulation. One patient with high-grade, nonocclusive PVT received anticoagulation alone. Patients with occlusive disease were treated with operative thrombectomy including intraoperative and postoperative thrombolysis (tissue plasminogen

  4. Management Strategy for Patients With Chronic Subclavian Vein Thrombosis.

    Science.gov (United States)

    Keir, Graham; Marshall, M Blair

    2017-02-01

    We performed a systematic review to determine best practice for the management of patients with chronic or subacute subclavian vein thrombosis. This condition is best managed with surgical excision of the first rib followed by long-term anticoagulation. Interventional techniques aimed at restoring patency are ineffective beyond 2 weeks postthrombosis. Additional therapeutic options should be made based on the severity of symptoms as well as vein status. Patients with milder symptoms are given decompression surgery followed by anticoagulation whereas patients with more severe symptoms are considered for either a jugular vein transposition or saphenous patch based on the vein characteristics. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. AITSO: A Tool for Spatial Optimization Based on Artificial Immune Systems

    Science.gov (United States)

    Zhao, Xiang; Liu, Yaolin; Liu, Dianfeng; Ma, Xiaoya

    2015-01-01

    A great challenge facing geocomputation and spatial analysis is spatial optimization, given that it involves various high-dimensional, nonlinear, and complicated relationships. Many efforts have been made with regard to this specific issue, and the strong ability of artificial immune system algorithms has been proven in previous studies. However, user-friendly professional software is still unavailable, which is a great impediment to the popularity of artificial immune systems. This paper describes a free, universal tool, named AITSO, which is capable of solving various optimization problems. It provides a series of standard application programming interfaces (APIs) which can (1) assist researchers in the development of their own problem-specific application plugins to solve practical problems and (2) allow the implementation of some advanced immune operators into the platform to improve the performance of an algorithm. As an integrated, flexible, and convenient tool, AITSO contributes to knowledge sharing and practical problem solving. It is therefore believed that it will advance the development and popularity of spatial optimization in geocomputation and spatial analysis. PMID:25678911

  6. AITSO: A Tool for Spatial Optimization Based on Artificial Immune Systems

    Directory of Open Access Journals (Sweden)

    Xiang Zhao

    2015-01-01

    Full Text Available A great challenge facing geocomputation and spatial analysis is spatial optimization, given that it involves various high-dimensional, nonlinear, and complicated relationships. Many efforts have been made with regard to this specific issue, and the strong ability of artificial immune system algorithms has been proven in previous studies. However, user-friendly professional software is still unavailable, which is a great impediment to the popularity of artificial immune systems. This paper describes a free, universal tool, named AITSO, which is capable of solving various optimization problems. It provides a series of standard application programming interfaces (APIs which can (1 assist researchers in the development of their own problem-specific application plugins to solve practical problems and (2 allow the implementation of some advanced immune operators into the platform to improve the performance of an algorithm. As an integrated, flexible, and convenient tool, AITSO contributes to knowledge sharing and practical problem solving. It is therefore believed that it will advance the development and popularity of spatial optimization in geocomputation and spatial analysis.

  7. An artificial neural network system to identify alleles in reference electropherograms.

    Science.gov (United States)

    Taylor, Duncan; Harrison, Ash; Powers, David

    2017-09-01

    Electropherograms are produced in great numbers in forensic DNA laboratories as part of everyday criminal casework. Before the results of these electropherograms can be used they must be scrutinised by analysts to determine what the identified data tells them about the underlying DNA sequences and what is purely an artefact of the DNA profiling process. This process of interpreting the electropherograms can be time consuming and is prone to subjective differences between analysts. Recently it was demonstrated that artificial neural networks could be used to classify information within an electropherogram as allelic (i.e. representative of a DNA fragment present in the DNA extract) or as one of several different categories of artefactual fluorescence that arise as a result of generating an electropherogram. We extend that work here to demonstrate a series of algorithms and artificial neural networks that can be used to identify peaks on an electropherogram and classify them. We demonstrate the functioning of the system on several profiles and compare the results to a leading commercial DNA profile reading system. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Production traits of artificially and naturally hatched geese in intensive and free-range systems: I. Growth traits.

    Science.gov (United States)

    Boz, M A; Sarica, M; Yamak, U S

    2017-04-01

    1. This study investigated the effect of incubation type and production system on geese growth traits. 2. A total of 216 geese were either naturally (114) or artificially (102) hatched and reared in intensive or free-range production systems (4 replicates each) until 18 weeks of age. 3. Weights of naturally hatched goslings (NHG) were significantly higher than artificially hatched goslings (AHG) at 2 weeks (644 vs. 536 g); however, weights of AHG were significantly higher than NHG at both 6 weeks (3245 vs. 3010 g) and 18 weeks (5212 vs. 4353 g). 4. AHG had better feed conversion ratios (FCRs) than NHG (6.21 vs. 6.46 at 18 weeks). Feed consumption of naturally hatched geese was found higher in first 4 weeks when compared to artificially hatched geese and artificially hatched geese consumed more feed than naturally hatched geese after 8 weeks. 5. Production system had insignificant effects on feed consumption, FCRs, viability and mutilation rates. 6. Slipped wings were more frequent in NHG than AHG (8.32% vs. 1.68% at 6 weeks; 23.84% vs. 5.12% between 7 and 18 weeks) and in free-range production when compared to intensive production (17.88% vs. 11.08% over the course of the production period). 7. The study results indicate that both artificially and NHG can be reared in free-range production systems without any loss in performance and in deference to animal welfare.

  9. Clinicopathological comparisons of open vein harvesting and endoscopic vein harvesting in coronary artery bypass grafting patients in Mashhad.

    Science.gov (United States)

    Amouzeshi, Ahmad; Teshnisi, Mohamad Abbassi; Zirak, Nahid; Shamloo, Alireza Sepehri; Hoseinikhah, Hamid; Alizadeh, Behzad; Moeinipour, Aliasghar

    2016-01-01

    Harvesting of the greater saphenous vein is almost an inevitable part of coronary artery bypass grafting (CABG) operations, and it is done by two main techniques, i.e., conventional or open vein harvesting (OVH) and the minimally-invasive endoscopic vein harvesting (EVH). This study aimed to compare these two techniques in off-pump CABG procedures with respect to clinical and pathological outcomes. This cohort study was conducted on CABG candidates during a one-year period from October 2013 through September 2014 in the Department of Cardiac Surgery at Mashhad University of Medical Sciences. Eighty-seven patients voluntarily underwent EVH, and another 86 patients matched for age, gender, and other cardiovascular risk factors were selected for OVH. They were followed up for six weeks, and the main outcome measures were infections of the wound, pain, duration of hospital stay, and the costs of hospitalization. Paired sample t-test, independent t-test, or their non-parametric equivalents and the chi-squared test were used by SPSS version 17.0 for data analysis. The mean duration of time for vein harvesting was shorter in the EVH group (p < 0.001), and the pain score was lower (p = 0.04). No infections occurred at the site of the wound. The length of hospital stay was not significantly different for the two groups (OVH versus EVH: 8.5 ± 3.3 versus 8.4 ± 3.2 days; p-value: 0.08). Hospitalization costs were significantly higher in the EVH group (OVH versus EVH: 5.8 ± 4.7 versus 7.3 ± 2.0 million Tomman; p-value: 0.008), yet no difference was diagnosed with respect to endothelial damage in the vein grafts harvested by the EVH and OVH techniques. EVH is considered as a minimally invasive and safe vein harvesting technique in our Center, and it can reduce the harvesting time and post-operative pain. In addition, its efficiency was similar to that of OVH.

  10. A status report on artificial lift systems and challenges in North Dakota horizontal completions

    Energy Technology Data Exchange (ETDEWEB)

    Fangmeier, K. [Amerada Hess Corp., ND (United States)

    2005-07-01

    Partially pressure depleted reservoirs and unfavorable horizontal flow geometries can impact artificial lift designs and diagnostics. In addition, terrain slugging, drilling fines, high gas volume fractions, H{sub 2}S gas and high bottom hole temperatures also pose challenges. This paper provides an overview of various systems utilized by Amerada Hess, a company which examines methods of reducing gas lift gas volumes to achieve maximum flow. A description of naturally fractured reservoirs and limited natural fractures was provided. A comparison was presented between the original conditions at Beaver Lodge Madison and existing conditions with horizontal development. Various artificial lift challenges were examined. It was suggested that high volume lift utilizing gas lift was the preferred artificial lift system for high volume wells. It was noted that downhole sensors can be used as an indicator of potential run life. However, reliability is limited by downhole operating temperatures and electrical ground faults. A comparison of friendly and unfriendly flow systems was presented, as well as a gas lift pressure chart. A summary of average gas volume systems was provided as well as an example of a response to increase drawdown. Examples of downhole Electric Submersible Pump (ESP) sensors were provided, as well as possible flowing pressure profiles in horizontal completion because of the constraints of lift capacity. It was concluded that a single point injection and proven gas lift system is the next step in high volume lift strategy. 2 tabs, 16 figs.

  11. Artificial neural network decision support systems for new product development project selection

    NARCIS (Netherlands)

    Thieme, R.J.; Song, Michael; Calantone, R.J.

    2000-01-01

    The authors extend and develop an artificial neural network decision support system and demonstrate how it can guide managers when they make complex new product development decisions. The authors use data from 612 projects to compare this new method with traditional methods for predicting various

  12. [Design of an artificial sphincter system with bio-feedback function based on MSP430].

    Science.gov (United States)

    Wang, Yong-kan; Yan, De-tian

    2005-11-01

    In this paper, we advance a new treating method for rectectomy postoperative anus incontinence, which is called "artificial sphincter system with biofeedback-function". The system simulates the function of human's sphincter and has entered into a stage of simulation experiments on animals.

  13. Leiomyosarcoma of inferior vena cava involving bilateral renal veins: Surgical challenges and reconstruction with upfront saphenous vein interposition graft for left renal vein outflow

    Directory of Open Access Journals (Sweden)

    Rishi Nayyar

    2010-01-01

    Full Text Available Leiomyosarcoma of inferior vena cava (IVC involving bilateral renal veins presents a surgical challenge. Herein, we report the successful management of two such cases using restoration of left renal venous outflow by saphenous vein interposition graft as first step of surgery. Then radical resection of tumor and right kidney was done. IVC was lastly reconstructed using Gore-Tex graft. This report highlights the surgical challenges to ensure radical resection. Furthermore, the importance of restoring left renal outflow in presence of concomitant right nephrectomy is discussed. Both the patients were disease free at six months with no loss of left renal glomerular filtration rate.

  14. Towards a Low-Cost Mobile Subcutaneous Vein Detection Solution Using Near-Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Simon Juric

    2014-01-01

    Full Text Available Excessive venipunctures are both time- and resource-consuming events, which cause anxiety, pain, and distress in patients, or can lead to severe harmful injuries. We propose a low-cost mobile health solution for subcutaneous vein detection using near-infrared spectroscopy, along with an assessment of the current state of the art in this field. The first objective of this study was to get a deeper overview of the research topic, through the initial team discussions and a detailed literature review (using both academic and grey literature. The second objective, that is, identifying the commercial systems employing near-infrared spectroscopy, was conducted using the PubMed database. The goal of the third objective was to identify and evaluate (using the IEEE Xplore database the research efforts in the field of low-cost near-infrared imaging in general, as a basis for the conceptual model of the upcoming prototype. Although the reviewed commercial devices have demonstrated usefulness and value for peripheral veins visualization, other evaluated clinical outcomes are less conclusive. Previous studies regarding low-cost near-infrared systems demonstrated the general feasibility of developing cost-effective vein detection systems; however, their limitations are restricting their applicability to clinical practice. Finally, based on the current findings, we outline the future research direction.

  15. Towards a low-cost mobile subcutaneous vein detection solution using near-infrared spectroscopy.

    Science.gov (United States)

    Juric, Simon; Flis, Vojko; Debevc, Matjaz; Holzinger, Andreas; Zalik, Borut

    2014-01-01

    Excessive venipunctures are both time- and resource-consuming events, which cause anxiety, pain, and distress in patients, or can lead to severe harmful injuries. We propose a low-cost mobile health solution for subcutaneous vein detection using near-infrared spectroscopy, along with an assessment of the current state of the art in this field. The first objective of this study was to get a deeper overview of the research topic, through the initial team discussions and a detailed literature review (using both academic and grey literature). The second objective, that is, identifying the commercial systems employing near-infrared spectroscopy, was conducted using the PubMed database. The goal of the third objective was to identify and evaluate (using the IEEE Xplore database) the research efforts in the field of low-cost near-infrared imaging in general, as a basis for the conceptual model of the upcoming prototype. Although the reviewed commercial devices have demonstrated usefulness and value for peripheral veins visualization, other evaluated clinical outcomes are less conclusive. Previous studies regarding low-cost near-infrared systems demonstrated the general feasibility of developing cost-effective vein detection systems; however, their limitations are restricting their applicability to clinical practice. Finally, based on the current findings, we outline the future research direction.

  16. Preventing Deep Vein Thrombosis

    Science.gov (United States)

    ... Physicians Contact Us My ACOG ACOG Departments Donate Shop Career Connection Home Clinical Guidance & Publications Practice Management ... skin. A clot also can form if blood flow is too slow the lining of a vein ...

  17. Finger Vein Recognition Based on Local Directional Code

    Science.gov (United States)

    Meng, Xianjing; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2012-01-01

    Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP), Local Derivative Pattern (LDP) and Local Line Binary Pattern (LLBP). However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD), this paper represents a new direction based local descriptor called Local Directional Code (LDC) and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP. PMID:23202194

  18. Finger Vein Recognition Based on Local Directional Code

    Directory of Open Access Journals (Sweden)

    Rongyang Xiao

    2012-11-01

    Full Text Available Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP, Local Derivative Pattern (LDP and Local Line Binary Pattern (LLBP. However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD, this paper represents a new direction based local descriptor called Local Directional Code (LDC and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP.

  19. Control system for solar tracking based on artificial vision; Sistema de control para seguimiento solar basado en vision artificial

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco Ramirez, Jesus Horacio; Anaya Perez, Maria Elena; Benitez Baltazar, Victor Hugo [Universidad de onora, Hermosillo, Sonora (Mexico)]. E-mail: jpacheco@industrial.uson.mx; meanaya@industrial.uson.mx; vbenitez@industrial.uson.mx

    2010-11-15

    This work shows how artificial vision feedback can be applied to control systems. The control is applied to a solar panel in order to track the sun position. The algorithms to calculate the position of the sun and the image processing are developed in LabView. The responses obtained from the control show that it is possible to use vision for a control scheme in closed loop. [Spanish] El presente trabajo muestra la manera en la cual un sistema de control puede ser retroalimentado mediante vision artificial. El control es aplicado en un panel solar para realizar el seguimiento del sol a lo largo del dia. Los algoritmos para calcular la posicion del sol y para el tratamiento de la imagen fueron desarrollados en LabView. Las respuestas obtenidas del control muestran que es posible utilizar vision para un esquema de control en lazo cerrado.

  20. Portal vein branching order helps in the recognition of anomalous right-sided round ligament: common features and variations in portal vein anatomy.

    Science.gov (United States)

    Yamashita, Rikiya; Yamaoka, Toshihide; Nishitai, Ryuta; Isoda, Hiroyoshi; Taura, Kojiro; Arizono, Shigeki; Furuta, Akihiro; Ohno, Tsuyoshi; Ono, Ayako; Togashi, Kaori

    2017-07-01

    This study aimed to evaluate the common features and variations of portal vein anatomy in right-sided round ligament (RSRL), which can help propose a method to detect and diagnose this anomaly. In this retrospective study of 14 patients with RSRL, the branching order of the portal tree was analyzed, with special focus on the relationship between the dorsal branch of the right anterior segmental portal vein (P A-D ) and the lateral segmental portal vein (P LL ), to determine the common features. The configuration of the portal vein from the main portal trunk to the right umbilical portion (RUP), the inclination of the RUP, and the number and thickness of the ramifications branching from the right anterior segmental portal vein (P A ) were evaluated for variations. In all subjects, the diverging point of the P A-D was constantly distal to that of the P LL . The portal vein configuration was I- and Z-shaped in nine and five subjects, respectively. The RUP was tilted to the right in all subjects. In Z-shaped subjects, the portal trunk between the branching point of the right posterior segmental portal vein and that of the P LL was tilted to the left in one subject and was almost parallel to the vertical plane in four subjects. Multiple ramifications were radially distributed from the P A in eight subjects, whereas one predominant P A-D branched from the P A in six subjects. Based on the diverging points of the P A-D and P LL , we proposed a three-step method for the detection and diagnosis of RSRL.

  1. ARTIFICIAL INTELLIGENCE IN DETERMINATION OF MARKETING CUSTOMER STRATEGY

    OpenAIRE

    Markić, Brano; Bijakšić, Sanja; Šantić, Marko

    2015-01-01

    Artificial intelligence is a computer-based analytical process that tends to create computational systems which we would incline to be called intelligent. Expert systems are the most important part of the artificial intelligence from economic perspective. Expert systems attempt to mimic the human thought process including reasoning and optimization. “Knowledge” is represented by a set of “if-then” rules in a form of knowledge base. The results of artificial intelligence system implementation ...

  2. ARTIFICIAL INTELLIGENCE IN DETERMINATION OF MARKETING CUSTOMER STRATEGY

    OpenAIRE

    Markić, Brano; Bijakšić, Sanja; Šantić, Marko

    2016-01-01

    Artificial intelligence is a computer-based analytical process that tends to create computational systems which we would incline to be called intelligent. Expert systems are the most important part of the artificial intelligence from economic perspective. Expert systems attempt to mimic the human thought process including reasoning and optimization. “Knowledge” is represented by a set of “if-then” rules in a form of knowledge base. The results of artificial intelligence system implementation ...

  3. Scimitar vein draining to the left atrium and a historical review of the scimitar syndrome

    International Nuclear Information System (INIS)

    Holt, Peter D.; Berdon, Walter E.; Marans, Zvi; Griffiths, Sylvia; Hsu, Daphne

    2004-01-01

    Scimitar vein draining to the left atrium is the rarest of the pulmonary venolobar anomalies with less than a dozen reported cases. A case is reported of a patient whose plain film radiographic findings showed a typical scimitar vein but whose echocardiography showed normal pulmonary venous drainage. Cardiac catheterization confirmed drainage of the scimitar vein to the left atrium and systemic arterial supply which was embolized. The case described is used to review the history of ''scimitar syndrome'' with reflections on the significant contributions of Halasz and colleagues, who in 1956 helped define the anatomy, and Neill and colleagues, who in 1960 described the familial occurrence and clinical spectrum of the condition. (orig.)

  4. Techniques of artificial intelligence applied to the electric power expansion distribution system planning problem; Tecnicas de inteligencia artificial aplicadas ao problema de planejamento da expansao do sistema de distribuicao de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Froes, Salete Maria

    1996-07-01

    A tool named Constrained Decision Problem (CDP), which is based on Artificial Intelligence and a specific application to Distribution System Planning is described. The CDP allows multiple objective optimization that does not, necessarily, result in a single optimal solution. First, a literature review covers published works related to Artificial Intelligence applications to Electric Power Distribution Systems, emphasizing feeder restoration and reconfiguration. Some concepts related to Artificial Intelligence are described, with particular attention to Planning and to Constrained Decision Problems. Following, an Electric Power System planning model is addressed by using the CDP tool. Some case studies illustrate the Distribution Planning model, which are compared with standard optimization models. Concluding, some comments establishing the possibilities of CDP applications are followed by a view on future developments. (author)

  5. Artificial Photosynthesis: Beyond Mimicking Nature

    International Nuclear Information System (INIS)

    Dau, Holger; Fujita, Etsuko; Sun, Licheng

    2017-01-01

    In this Editorial, Guest Editors Holger Dau, Etsuko Fujita, and Licheng Sun introduce the Special Issue of ChemSusChem on “Artificial Photosynthesis for Sustainable Fuels”. Here, they discuss the need for non-fossil based fuels, introduce both biological and artificial photosynthesis, and outline various important concepts in artificial photosynthesis, including molecular and solid-state catalysts for water oxidation and hydrogen evolution, catalytic CO 2 reduction, and photoelectrochemical systems.

  6. The Auscultation of a Carbon Dioxide Embolization Event during Endoscopic Vein Harvest

    Directory of Open Access Journals (Sweden)

    Erik Strauss

    2016-01-01

    Full Text Available Endoscopic vein harvest in preparation for coronary artery bypass surgery has become a preferred method of procuring saphenous vein. Several case reports have documented carbon dioxide (CO2 embolization with this procedure as well as CO2 embolization during other laparoscopic surgeries (Markar et al., 2010. Although uncommon, the potential for CO2 entrainment through an open vein or through absorption by vascular structures exists and should be recognized (Lin et al., 2003. We report a case of CO2 embolization during EVH for a 77-year-old patient who underwent CABG that was identified early by the cardiac surgeon through the indirect auscultation of a mill-wheel murmur after the pericardium was opened. This may be the first reported case of a murmur related to air emboli identified without the use of a precordial Doppler probe or a stethoscope. This diagnosis was further supported by TEE before systemic hypotension or cardiovascular collapse occurred.

  7. VWPS: A Ventilator Weaning Prediction System with Artificial Intelligence

    Science.gov (United States)

    Chen, Austin H.; Chen, Guan-Ting

    How to wean patients efficiently off mechanical ventilation continues to be a challenge for medical professionals. In this paper we have described a novel approach to the study of a ventilator weaning prediction system (VWPS). Firstly, we have developed and written three Artificial Neural Network (ANN) algorithms to predict a weaning successful rate based on the clinical data. Secondly, we have implemented two user-friendly weaning success rate prediction systems; the VWPS system and the BWAP system. Both systems could be used to help doctors objectively and effectively predict whether weaning is appropriate for patients based on the patients' clinical data. Our system utilizes the powerful processing abilities of MatLab. Thirdly, we have calculated the performance through measures such as sensitivity and accuracy for these three algorithms. The results show a very high sensitivity (around 80%) and accuracy (around 70%). To our knowledge, this is the first design approach of its kind to be used in the study of ventilator weaning success rate prediction.

  8. Preliminary study of lead isotopes in the carbonate-silica veins of Trench 14, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Zartman, R.E.; Kwak, L.M.

    1993-01-01

    The sub-vertical carbonate-silica veins filling the Bow Ridge Fault, where exposed in Trench 14 on the east side of Yucca Mountain, carry a lead isotopic signature that can be explained in terms of local sources. Two isotopically distinguishable--silicate and carbonate--fractions of lead are recognized within the vein system as well as in overlying surficial calcrete deposits. The acid-insoluble silicate fraction is contributed largely from the decomposing Miocene volcanic tuff, which forms the wall rock of the fault zone and is a ubiquitous component of the overlying soil. Lead contained in the silicate fraction approaches in isotopic composition that of the Miocene volcanic rocks of Yucca Mountain, but diverges from it in some samples by being more enriched in uranogenic isotopes. The carbonate fraction of lead in both vein and calcrete samples resides dominantly in the HCl- and CH 3 COOH-soluble calcite. HCl evidently also attacks and removes lead from silicate phases, but the milder CH 3 COOH dissolution procedure oftentimes identifies a significantly more radiogenic lead in the calcite. Wind-blown particulate matter brought to the area from Paleozoic and Late Proterozoic limestones in surrounding mountains may be the ultimate source of the calcite. Isotopically more uniform samples suggest that locally the basaltic ash and other volcanic rock have contributed most of the lead to both fractions of the vein system. An important finding of this study is that the data does not require the more exotic mechanisms or origins that have been proposed for the veins. Instead, the remarkably similar lead isotopic properties of the veins to those of the soil calcretes support their interpretation as a surficial, pedogenic phenomenon

  9. A Fault Diagnosis Approach for the Hydraulic System by Artificial Neural Networks

    OpenAIRE

    Xiangyu He; Shanghong He

    2014-01-01

    Based on artificial neural networks, a fault diagnosis approach for the hydraulic system was proposed in this paper. Normal state samples were used as the training data to develop a dynamic general regression neural network (DGRNN) model. The trained DGRNN model then served as the fault determinant to diagnose test faults and the work condition of the hydraulic system was identified. Several typical faults of the hydraulic system were used to verify the fault diagnosis approach. Experiment re...

  10. A Tight Spot After Pulmonary Vein Catheter Ablation

    NARCIS (Netherlands)

    Amir, Rabia; Yeh, Lu; Montealegre-Gallegos, Mario; Saraf, Rabya; Matyal, Robina; Mahmood, Feroze

    2016-01-01

    A 52-YEAR-OLD woman with a history of embolic stroke due to paroxysmal atrial fibrillation was referred to the authors’ institution for epicardial surgical pulmonary vein isolation with left atrial appendage resection. The patient had 2 previous failed pulmonary vein catheter ablations. Dense

  11. Clinical and Ultrasonographic Evaluation of Lower-extremity Vein Thrombosis in Behcet Syndrome

    Science.gov (United States)

    Seyahi, Emire; Cakmak, Osman Serdal; Tutar, Burcin; Arslan, Caner; Dikici, Atilla Suleyman; Sut, Necdet; Kantarci, Fatih; Tuzun, Hasan; Melikoglu, Melike; Yazici, Hasan

    2015-01-01

    Abstract Vascular involvement can be seen in up to 40% of patients with Behcet syndrome (BS), the lower-extremity vein thrombosis (LEVT) being the most common type. The aim of the current study was to compare venous Doppler findings and clinical features between BS patients with LEVT and control patients diagnosed as having LEVT due to other causes. All consecutive 78 patients (71 men, 7 women; mean age 38.6 ± 10.3 years) with LEVT due to BS and 50 control patients (29 men, 21 women; mean age 42.0 ± 12.5 years) who had LEVT due to other causes, or idiopathic, were studied with the help of a Doppler ultrasonography after a detailed clinical examination. Patterns of venous disease were identified by cluster analyses. Clinical features of chronic venous disease were assessed using 2 classification systems. Venous claudication was also assessed. Patients with BS were more likely to be men, had significantly earlier age of onset of thrombosis, and were treated mainly with immunosuppressives and less frequently with anticoagulants. Furthermore, they had significantly more bilateral involvement, less complete recanalization, and more frequent collateral formation. While control patients had a disorganized pattern of venous involvement, BS patients had a contiguous and symmetric pattern, involving all deep and superficial veins of the lower extremities, with less affinity for crural veins. Clinical assessment, as measured by the 2 classification systems, also indicated a more severe disease among the BS patients. In line, 51% of the BS patients suffered from severe post-thrombotic syndrome (PTS) and 32% from venous claudication, whereas these were present in 8% and 12%, respectively, among the controls. Among BS patients, a longer duration of thrombosis, bilateral femoral vein involvement, and using no anticoagulation along with immunosuppressive treatment when first diagnosed were found to be associated independently with severe PTS. Lower-extremity vein

  12. Cytomegalovirus retinitis after central retinal vein occlusion in a patient on systemic immunosuppression: does venooclusive disease predispose to cytomegalovirus retinitis in patients already at risk?

    Directory of Open Access Journals (Sweden)

    Welling JD

    2012-04-01

    Full Text Available John D Welling, Ahmad B Tarabishy, John ChristoforidisDepartment of Ophthalmology, Havener Eye Institute, Ohio State University, Columbus, OH, USAAbstract: Cytomegalovirus (CMV retinitis remains the most common opportunistic ocular infection in immunocompromised patients. Patients with immunocompromising diseases, such as acquired immunodeficiency syndrome, inherited immunodeficiency states, malignancies, and those on systemic immunosuppressive therapy, are known to be at risk. Recently, it has been suggested that patients undergoing intravitreal injection of immunosuppressive agents may also be predisposed. One previous case report speculated that there may be an additional risk for CMV retinitis in acquired immunodeficiency syndrome patients with venoocclusive disease. This case study presents a case of CMV retinitis following central retinal vein occlusion in a patient on systemic immunosuppressants.Keywords: cytomegalovirus retinitis, central retinal vein occlusion, immunosuppression, solid organ transplant, venous stasis, risk factor

  13. Updated cannulation technique for tissue plasminogen activator injection into peripapillary retinal vein for central retinal vein occlusion.

    Science.gov (United States)

    van Overdam, Koen A; Missotten, Tom; Spielberg, Leigh H

    2015-12-01

    To update the surgical technique in which a vitrectomy is performed and a retinal branch vein is cannulated and infused with recombinant tissue plasminogen activator (RTPA) to treat central retinal vein occlusion (CRVO) in patients who present with very low visual acuity (VA). Twelve consecutive patients (12 eyes) with CRVO and low VA (logMAR >1.00) at presentation were treated using this method. Cannulation of a peripapillary retinal vein and stable injection of RTPA was successfully performed without surgery-related complications in all 12 eyes. At 12 months after surgery, 8 of the 12 patients (67%) experienced at least one line of improvement in best corrected visual acuity; 6 of the 12 (50%) improved ≥5 lines and 2 (17%) improved ≥8 lines. After additional grid laser and/or subconjunctival or intravitreal corticosteroids, the mean decrease in central foveal thickness was 260 μm, and the mean total macular volume decreased from 12.10 mm(3) to 9.24 mm(3) . Four patients received panretinal photocoagulation to treat either iris neovascularization (n = 2) or neovascularization of the retina and/or disc (n = 2). Administration of RTPA via a peripapillary vein using this updated technique provides an alternative or additional treatment option for patients with very low VA after CRVO. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. A neural network based artificial vision system for licence plate recognition.

    Science.gov (United States)

    Draghici, S

    1997-02-01

    This paper presents a neural network based artificial vision system able to analyze the image of a car given by a camera, locate the registration plate and recognize the registration number of the car. The paper describes in detail various practical problems encountered in implementing this particular application and the solutions used to solve them. The main features of the system presented are: controlled stability-plasticity behavior, controlled reliability threshold, both off-line and on-line learning, self assessment of the output reliability and high reliability based on high level multiple feedback. The system has been designed using a modular approach. Sub-modules can be upgraded and/or substituted independently, thus making the system potentially suitable in a large variety of vision applications. The OCR engine was designed as an interchangeable plug-in module. This allows the user to choose an OCR engine which is suited to the particular application and to upgrade it easily in the future. At present, there are several versions of this OCR engine. One of them is based on a fully connected feedforward artificial neural network with sigmoidal activation functions. This network can be trained with various training algorithms such as error backpropagation. An alternative OCR engine is based on the constraint based decomposition (CBD) training architecture. The system has showed the following performances (on average) on real-world data: successful plate location and segmentation about 99%, successful character recognition about 98% and successful recognition of complete registration plates about 80%.

  15. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  16. Endo-aneurysmorrhaphy of a giant aneurysm of the subclavian vein

    Directory of Open Access Journals (Sweden)

    Ahmed Afifi

    2012-07-01

    Full Text Available Venous aneurysms are relatively rare anomalies which can affect different parts of the vascular system. Diagnosis and management of this condition could pose important problems. We here report a giant false aneurysm of the subclavian vein with emphasis on the thought process that determined the management strategy.

  17. Palm vein recognition based on directional empirical mode decomposition

    Science.gov (United States)

    Lee, Jen-Chun; Chang, Chien-Ping; Chen, Wei-Kuei

    2014-04-01

    Directional empirical mode decomposition (DEMD) has recently been proposed to make empirical mode decomposition suitable for the processing of texture analysis. Using DEMD, samples are decomposed into a series of images, referred to as two-dimensional intrinsic mode functions (2-D IMFs), from finer to large scale. A DEMD-based 2 linear discriminant analysis (LDA) for palm vein recognition is proposed. The proposed method progresses through three steps: (i) a set of 2-D IMF features of various scale and orientation are extracted using DEMD, (ii) the 2LDA method is then applied to reduce the dimensionality of the feature space in both the row and column directions, and (iii) the nearest neighbor classifier is used for classification. We also propose two strategies for using the set of 2-D IMF features: ensemble DEMD vein representation (EDVR) and multichannel DEMD vein representation (MDVR). In experiments using palm vein databases, the proposed MDVR-based 2LDA method achieved recognition accuracy of 99.73%, thereby demonstrating its feasibility for palm vein recognition.

  18. [Cockett's syndrome, May-Thurner syndrome, or iliac vein compression syndrome].

    Science.gov (United States)

    Gil Martín, A R; Carreras Aja, M; Arrieta Ardieta, I; Labayen Azparren, I

    2014-01-01

    Iliac vein compression syndrome (also known as May-Thurner syndrome or Cockett's syndrome) is a rare clinical entity in which the left common iliac vein is compressed when it passes between the right common iliac artery and the spine. The sustained compression and trauma caused by the pulsatile force of the artery on the vein damage the intima and lead to the formation of membranes or bands in the vascular lumen that hinder or obstruct the flow of blood in the vein, favoring thrombus formation. The current treatment strategy of choice is endovascular vein patch angioplasty and stenting with the aim of improving the caliber of the lumen and enabling normal venous drainage. We present two cases of May-Thurner syndrome and review the clinical and CT findings. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  19. Artificial intelligence utilization in power generation units control systems; Utilizacao de inteligencia artificial em sistemas de controle de unidades geradoras

    Energy Technology Data Exchange (ETDEWEB)

    Souza, G N [CEPEL, Rio de Janeiro, RJ (Brazil); Mendes, S B [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1992-12-31

    To the implementation of the logics of control in a hydroelectric power plant artificial languages or complexes formalisms are used which cause error introduction in the description process of such logic. This work suggests the use of an intelligent and interactive system with interface in natural language to the control description as a solution to this problem. 28 refs., 3 figs.

  20. Artificial intelligence utilization in power generation units control systems; Utilizacao de inteligencia artificial em sistemas de controle de unidades geradoras

    Energy Technology Data Exchange (ETDEWEB)

    Souza, G.N. [CEPEL, Rio de Janeiro, RJ (Brazil); Mendes, S.B. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1991-12-31

    To the implementation of the logics of control in a hydroelectric power plant artificial languages or complexes formalisms are used which cause error introduction in the description process of such logic. This work suggests the use of an intelligent and interactive system with interface in natural language to the control description as a solution to this problem. 28 refs., 3 figs.

  1. Pattern of venous collateral development after splenic vein occlusion in an extended Whipple procedure : comparison with collateral vein pattern in cases of sinistral portal hypertension.

    Science.gov (United States)

    Strasberg, Steven M; Bhalla, Sanjeev; Sanchez, Luis A; Linehan, David C

    2011-11-01

    The risks of developing sinistral portal hypertension as a result of occlusion of the splenic vein close to its termination during a Whipple procedure are unclear. Our purpose was to compare the pattern of venous collateral development after splenic vein ligation in an extended Whipple procedure with the pattern of collateral development in cases of sinistral portal hypertension. Five patients underwent an extended Whipple procedure in which the splenic vein was divided and not reconstructed. Six to eight months later detailed mapping of venous return from the spleen was determined by contrast-enhanced multidetector computed tomography or in one case by 3D contrast-enhanced MRI. Spleen size and length of residual patent splenic vein were also measured. The literature on sinistral portal hypertension was evaluated to ascertain whether the venous collateral pattern in cases of left-sided portal hypertension was similar to the pattern that developed when the splenic vein was ligated at its termination in the Whipple procedure. A length of splenic vein remained patent in all five patients, measuring 4.5 to 11.5 cm from the spleen. Splenomegaly did not develop. Blood returned from the spleen by multiple collaterals including collaterals in the omentum and mesocolon. These types of collaterals do not develop in sinistral portal hypertension, nor is residual patent splenic vein seen. Ligation of the splenic vein close to its termination in five patients resulted in a pattern of venous return different from patients that have developed left-sided portal hypertension.

  2. Assessment of MRI Contrast Agent Kinetics via Retro-Orbital Injection in Mice: Comparison with Tail Vein Injection.

    Science.gov (United States)

    Wang, Fang; Nojima, Masanori; Inoue, Yusuke; Ohtomo, Kuni; Kiryu, Shigeru

    2015-01-01

    It is not known whether administration of contrast agent via retro-orbital injection or the tail vein route affects the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI). Therefore, we compared the effects of retro-orbital and tail vein injection on the kinetics of the contrast agent used for MRI in mice. The same group of nine healthy female mice received contrast agent via either route. An extracellular contrast agent was infused via the tail vein and retro-orbital vein, in random order. Dynamic contrast-enhanced MRI was performed before and after administering the contrast agent. The contrast effects in the liver, kidney, lung, and myocardium were assessed. The average total times of venous puncture and mounting of the injection system were about 10 and 4 min for the tail vein and retro-orbital route, respectively. For all organs assessed, the maximum contrast ratio occurred 30 s after administration and the time course of the contrast ratio was similar with either routes. For each organ, the contrast ratios correlated strongly; the contrast ratios were similar. The retro-orbital and tail vein routes afforded similar results in terms of the kinetics of the contrast agent. The retro-orbital route can be used as a simple efficient alternative to tail vein injection for dynamic contrast-enhanced MRI of mice.

  3. Quartz-molybdenite veins in the Priestly Lake granodiorite, north-central Maine

    Science.gov (United States)

    Ayuso, Robert A.; Shank, Stephen G.

    1983-01-01

    Quartz-molybdenite veins up to 15 cm in width occur in fine to medium-grained porphyritic biotite-hornblende granodiorite at Priestly Lake north-central Maine. An area of about 150 m x 150 m contains quartz-molybdenite veins; a larger area is characterized by barren quartz veins. Quartz-molybdenite veins are concentrated within the most felsic variants of the intrusion as suggested by lower mafic mineral contents. The pluton has a narrow range in SiO2 (67-70 wt.%), major oxides, and in trace-element compositions. Molybdenite occurs as coarse grained clusters in pockets within the quartz veins, and fills fractures in the quartz veins and host rocks. Disseminated molybdenite in the granodiorite is relatively rare and occurs only in the area characterized by a high density of quartz veins (up to 50 veins per square meter). Alteration envelopes along the quartz veins are very thin or absent, although in some areas the granodiorite appears to be selectively and pervasively altered. Sericite, chlorite, epidote, calcite, pyrite, and quartz are concentrated near the quartz-molybdenite veins. Many of the field and geochemical characteristics of the Priestly Lake pluton are unlike those of major molybdenum-producing areas (Climax, Henderson, Urad). For example, the area of alteration seems to be of limited extent, the host rock is not intensely altered hydrothermally at the surface, the density of fractures is rather low in the mineralized area, and the amount of disseminated molybdenite appears to be small. However, the Priestly Lake pluton may be a small fraction of a concealed batholith as suggested by geophysical data. It is conceivable that the type of mineralization at the surface might be the expression of more extensive molybdenite mineralization at depth. The quartz-molybdenite veins in the Priestly Lake pluton are significant because they indicate that potential molybdenum sources for producing mineralized granites were available at depth. Future studies should be

  4. Embodied artificial evolution: Artificial evolutionary systems in the 21st Century.

    Science.gov (United States)

    Eiben, A E; Kernbach, S; Haasdijk, Evert

    2012-12-01

    Evolution is one of the major omnipresent powers in the universe that has been studied for about two centuries. Recent scientific and technical developments make it possible to make the transition from passively understanding to actively using evolutionary processes. Today this is possible in Evolutionary Computing, where human experimenters can design and manipulate all components of evolutionary processes in digital spaces. We argue that in the near future it will be possible to implement artificial evolutionary processes outside such imaginary spaces and make them physically embodied. In other words, we envision the "Evolution of Things", rather than just the evolution of digital objects, leading to a new field of Embodied Artificial Evolution (EAE). The main objective of this paper is to present a unifying vision in order to aid the development of this high potential research area. To this end, we introduce the notion of EAE, discuss a few examples and applications, and elaborate on the expected benefits as well as the grand challenges this developing field will have to address.

  5. Medical applications of artificial intelligence

    CERN Document Server

    Agah, Arvin

    2013-01-01

    Enhanced, more reliable, and better understood than in the past, artificial intelligence (AI) systems can make providing healthcare more accurate, affordable, accessible, consistent, and efficient. However, AI technologies have not been as well integrated into medicine as predicted. In order to succeed, medical and computational scientists must develop hybrid systems that can effectively and efficiently integrate the experience of medical care professionals with capabilities of AI systems. After providing a general overview of artificial intelligence concepts, tools, and techniques, Medical Ap

  6. A new design concept for knitted external vein-graft support mesh.

    Science.gov (United States)

    Singh, Charanpreet; Wang, Xungai

    2015-08-01

    Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights

  7. Anatomical variations of the right hepatic veins and their relevance to surgery.

    Science.gov (United States)

    Hribernik, Marija; de Cecchis, Lucio; Trotovsek, Blaz; Gadzijev, Eldar M; Ravnik, Dean

    2003-01-01

    In a morphological study of the right hepatic veins anatomical characteristics of surgical importance were looked for. 110 cadaveric human livers were prepared by the corrosion casts method. The confluence patterns of the superior right hepatic vein, the hepatocaval confluence, the accessory right hepatic veins and the anastomoses between hepatic veins in the right hemiliver were examined. Four types of the superior right hepatic vein, based on the length of its trunk and the confluence pattern of its main tributaries were determined and their frequency was calculated. Type I was found in 20%, type II in 40%, type III in 25% and type IV in 15%. Accessory right hepatic veins with a minimal caliber of 0.4 cm, which were always present in type IV, were also found in other types, all together in 27% of the casts. The tributary-free part of the superior right hepatic vein at hepatocaval confluence was longer than 1 cm in 77%. In the right hemiliver 109 anastomoses were found in 29/110 liver casts. Knowing the characteristics of different superior right hepatic vein types and of the accessory right hepatic veins may be useful in segment-oriented liver resections and in right side living donor resections.

  8. Artificial frame filling using adaptive neural fuzzy inference system for particle image velocimetry dataset

    Science.gov (United States)

    Akdemir, Bayram; Doǧan, Sercan; Aksoy, Muharrem H.; Canli, Eyüp; Özgören, Muammer

    2015-03-01

    Liquid behaviors are very important for many areas especially for Mechanical Engineering. Fast camera is a way to observe and search the liquid behaviors. Camera traces the dust or colored markers travelling in the liquid and takes many pictures in a second as possible as. Every image has large data structure due to resolution. For fast liquid velocity, there is not easy to evaluate or make a fluent frame after the taken images. Artificial intelligence has much popularity in science to solve the nonlinear problems. Adaptive neural fuzzy inference system is a common artificial intelligence in literature. Any particle velocity in a liquid has two dimension speed and its derivatives. Adaptive Neural Fuzzy Inference System has been used to create an artificial frame between previous and post frames as offline. Adaptive neural fuzzy inference system uses velocities and vorticities to create a crossing point vector between previous and post points. In this study, Adaptive Neural Fuzzy Inference System has been used to fill virtual frames among the real frames in order to improve image continuity. So this evaluation makes the images much understandable at chaotic or vorticity points. After executed adaptive neural fuzzy inference system, the image dataset increase two times and has a sequence as virtual and real, respectively. The obtained success is evaluated using R2 testing and mean squared error. R2 testing has a statistical importance about similarity and 0.82, 0.81, 0.85 and 0.8 were obtained for velocities and derivatives, respectively.

  9. Chemical analysis of multicomponent aqueous solutions using a system of nonselective sensor and artificial neural networks

    International Nuclear Information System (INIS)

    Vlasov, Yu.G.; Legin, A.V.; Rudnitskaya, A.M.; Amiko, A.D.; Natale, K.D.

    1997-01-01

    With the aim of creating a multisensor system for determining heavy-metal cations (Cu 2+ , Pb 2+ , Cd 2+ , and Zn 2+ ) and inorganic anions (Cl - , F - , and SO 4 2- ), measurements in mixed solutions were carried out with the use of an array of sensors based on chalcogenide glass electrodes, and the possibility of using various methods of mathematical processing of the resulting intricate signals was studied. Three methods of data processing were used: multilinear regression, partial least squares, and artificial neural networks. It was found that the multisensor system proposed were suitable for determining all of the analytes with an accuracy of 1-10%. Because the responses of sensors in solutions of complex composition deviated from linearity, the lowest determination errors were obtained with the use of an artificial neural network. As to the method of data securing (nonselective response of a sensor array) and processing (artificial neural network), the multisensor system developed may be considered a prototype of a device of the electronic tongue type

  10. Serial 2-point ultrasonography plus D-Dimer vs whole-leg color-coded doppler ultrasonography for diagnosing suspected symptomatic deep vein thrombosis - A randomized controlled trial

    NARCIS (Netherlands)

    Bernardi, Enrico; Camporese, Giuseppe; Buller, Harry R.; Siragusa, Sergio; Imberti, Davide; Berchio, Arrigo; Ghirarduzzi, Angelo; Verlato, Fabio; Anastasio, Raffaela; Prati, Carolina; Piccioli, Andrea; Pesavento, Raffaele; Bova, Carlo; Maltempi, Patrizia; Zanatta, Nello; Cogo, Alberto; Cappelli, Roberto; Bucherini, Eugenio; Cuppini, Stefano; Noventa, Franco; Prandoni, Paolo

    2008-01-01

    Context Patients with suspected deep vein thrombosis ( DVT) of the lower extremities are usually investigated with ultrasonography either by the proximal veins ( 2-point ultrasonography) or the entire deep vein system ( whole- leg ultrasonography). The latter approach is thought to be better based

  11. Implanted artificial heart with radioisotope power source

    Energy Technology Data Exchange (ETDEWEB)

    Shumakov, V I; Griaznov, G M; Zhemchuzhnikov, G N; Kiselev, I M; Osipov, A P

    1983-02-01

    An atomic artificial heart for orthotopic implantation was developed with the following characteristics: volume, 1.2 L; weight, 1.5 kg; radioisotope power, 45 W; operating life, up to 5 years; hemodynamics, similar to natural hemodynamics. The artificial heart includes a thermal drive with systems for regulating power, feeding steam into the cylinders, return of the condensate to the steam generator, and delivery of power to the ventricles and heat container. The artificial heart is placed in an artificial pericardium partially filled with physiologic solution. It uses a steam engine with two operating cylinders that separately drive the left and right ventricles. There is no electronic control system in the proposed design. The operation of the heat engine is controlled, with preservation of autoregulation by the vascular system of the body. The separate drives for the ventricles is of primary importance as it provides for operation of the artificial heart through control of cardiac activity by venous return. Experimental testing on a hydromechanical bench demonstrated effective autoregulation.

  12. Formation of quartz veins by local dissolution and transport of silica

    Energy Technology Data Exchange (ETDEWEB)

    Wangen, Magnus; Munz, Ingrid Anne

    2004-08-01

    A simple model is proposed for the (often) thick quartz veins observed in the Modum Complex in Southern Norway. The formation of these veins cannot easily be explained by silica imported by hot ascending fluids. The proposed model has dissolution in the host rock adjacent to the veins as the source for silica. The suggested process for vein formation is represented by a reaction-diffusion equation, and the process is studied in terms of a Damkoehler number. Estimates for the growth rate of quartz cement are derived. The estimates for the growth rate can be used to constrain poorly known parameters of the vein formation process, like for instance, the degree of supersaturation in the host rock. (Author)

  13. Primary extraskeletal mesenchymal chondrosarcoma arising from the iliac vein

    Directory of Open Access Journals (Sweden)

    Hua Zhang

    2017-10-01

    Full Text Available The iliac vein is an extremely rare site for mesenchymal chondrosarcoma, and patients with primary extraskeletal mesenchymal chondrosarcoma arising from a vein always suffer a very poor prognosis. We report a case of a 45-year-old female who presented with a 5-month history of left leg edema in 2015. Contrast-enhanced computed tomography showed a large mass in the left iliac vein with scattered calcifications. Wide-margin resection was performed, and histopathologic and immunohistochemical analyses confirmed the presence of intraluminal mesenchymal chondrosarcoma with local invasion out of the vein wall. Due to poor patient compliance, postoperative neoadjuvant chemotherapy and radiotherapy were not started, and a bone scan performed 16 weeks postoperatively showed multiple bone metastases. The patient died on the twenty-fourth postoperative week.

  14. Iliac Vein Compression Syndrome due to Bladder Distention Caused by Urethral Calculi

    Directory of Open Access Journals (Sweden)

    Akiko Ikegami

    2015-01-01

    Full Text Available We report a rare case of iliac vein compression syndrome caused by urethral calculus. A 71-year-old man had a history of urethral stenosis. He complained of bilateral leg edema and dysuria for 1 week. Physical examination revealed bilateral distention of the superficial epigastric veins, so obstruction of both common iliac veins or the inferior vena cava was suspected. Plain abdominal computed tomography showed a calculus in the pendulous urethra, distention of the bladder (as well as the right renal pelvis and ureter, and compression of the bilateral common iliac veins by the distended bladder. Iliac vein compression syndrome was diagnosed. Bilateral iliac vein compression due to bladder distention (secondary to neurogenic bladder, benign prostatic hyperplasia, or urethral calculus as in this case is an infrequent cause of acute bilateral leg edema. Detecting distention of the superficial epigastric veins provides a clue for diagnosis of this syndrome.

  15. The study of multi-detector CT on the grouping and measuring of the hepatic veins

    International Nuclear Information System (INIS)

    Wang Xianliang; Dong Guang; Geng Hai; Wang Wengang; Li Linkun; Gao Wei; Wang Rongfang

    2007-01-01

    Objective: To study the three-dimensional topography of the hepatic vein (HV), the inferior vena cava(IVC) and the inferior right hepatic vein(IRHV) in the retrohepatic and pre-IVC tunnel in human beings, and to provide an anatomic reference for liver surgery. Methods: One hundred and ten volunteers underwent CT scanning at 60 to 75 s after injection of contrast medium, and their HV, IVC and IRHV were reconstructed into MPR and 3D-MIP images. The hepatic veins were grouped according to the way by which the hepatic vein enters IVC. The angle between the right hepatic vein and the middle hepatic vein or the trunk of hepatic vein was measured, and the width from right hepatic vein to middle hepatic vein or to the trunk of hepatic vein on IVC was recorded. The frequency of IRHV was observed, and the length of the tunnel was measured. Results: Among the 110 volunteers, there were 6 cases (5.45%) with three hepatic veins respectively entering IVC, 98 cases (89.10%) with right hepatic vein and a common trunk of the middle hepatic vein and the left hepatic vein entering IVC, and 6 cases (5.45%) with left hepatic vein and a common trunk of the right hepatic vein and the middle hepatic vein entering IVC. The mean value of the angles between the right hepatic vein and the middle hepatic vein or the mink of hepatic vein was (55 ± 18) degree. The width from the right hepatic vein to the middle hepatic vein or to the trunk of hepatic vein was (21 ± 7)mm. The IRHV was observed in 30 cases(27.27%). The mean value of the tunnel length was (53 ± 11) mm. Conclusion: The parameters of the retrohepatic and pre-IVC tunnel in human beings can be measured accurately by the imaging of MPR, which can provide an anatomic reference for the liver surgery. (authors)

  16. Bibliography: Artificial Intelligence.

    Science.gov (United States)

    Smith, Richard L.

    1986-01-01

    Annotates reference material on artificial intelligence, mostly at an introductory level, with applications to education and learning. Topics include: (1) programing languages; (2) expert systems; (3) language instruction; (4) tutoring systems; and (5) problem solving and reasoning. (JM)

  17. Right ovarian vein drainage variant: Is there a relationship with pelvic varices?

    International Nuclear Information System (INIS)

    Koc, Zafer; Ulusan, Serife; Oguzkurt, Levent

    2006-01-01

    Objective: To correlate right ovarian vein (ROV) variations that drain into the right renal vein (RRV) with the presence of pelvic varices. Materials and methods: Routine abdominal multidetector-row computed tomography scans of 324 women were analyzed for the presence and type of ROV variations in this retrospective study. The subjects were divided into 2 groups: those with ROV variations and those without such variations. The diameters of the subjects' ROV, left ovarian vein (LOV), and parauterine veins were measured. Pelvic varices and the presence and degree of ovarian vein reflux were noted and compared between the 2 groups. The χ 2 -test and the Pearson correlation test were used for statistical analysis. Results: Thirty-two (9.9%) of 324 women studied exhibited ROV variant that drained into the right renal vein, and the remaining subjects (90.1%) exhibited a normal pattern of ROV drainage that flowed directly into the inferior vena cava. Pelvic varices were identified in 59 (18%) of the subjects. Reflux was not observed in any patient without pelvic varices. Fifty-seven of 59 women exhibited ovarian vein reflux. In 56 of those 57 individuals, reflux occurred only in the LOV, and in 1 subject, reflux was noted predominantly in the ROV. No significant relationship between the presence of an ROV that drained into the right renal vein and pelvic varices was noted. Conclusion: Although right-sided pelvic varices associated with right ovarian vein drainage variations are rare, anatomic variations of the right ovarian vein are not. This study did not find an association between the presence of right ovarian vein and pelvic varices

  18. Right ovarian vein drainage variant: Is there a relationship with pelvic varices?

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Zafer [Baskent Universitesi, Adana Hastanesi, Radyoloji Boeluemue, Serin Evler 39, Sok. No. 6 Yueregir, Adana (Turkey)]. E-mail: koczafer@gmail.com; Ulusan, Serife [Baskent Universitesi, Adana Hastanesi, Radyoloji Boeluemue, Serin Evler 39, Sok. No. 6 Yueregir, Adana (Turkey); Oguzkurt, Levent [Baskent Universitesi, Adana Hastanesi, Radyoloji Boeluemue, Serin Evler 39, Sok. No. 6 Yueregir, Adana (Turkey)

    2006-09-15

    Objective: To correlate right ovarian vein (ROV) variations that drain into the right renal vein (RRV) with the presence of pelvic varices. Materials and methods: Routine abdominal multidetector-row computed tomography scans of 324 women were analyzed for the presence and type of ROV variations in this retrospective study. The subjects were divided into 2 groups: those with ROV variations and those without such variations. The diameters of the subjects' ROV, left ovarian vein (LOV), and parauterine veins were measured. Pelvic varices and the presence and degree of ovarian vein reflux were noted and compared between the 2 groups. The {chi}{sup 2}-test and the Pearson correlation test were used for statistical analysis. Results: Thirty-two (9.9%) of 324 women studied exhibited ROV variant that drained into the right renal vein, and the remaining subjects (90.1%) exhibited a normal pattern of ROV drainage that flowed directly into the inferior vena cava. Pelvic varices were identified in 59 (18%) of the subjects. Reflux was not observed in any patient without pelvic varices. Fifty-seven of 59 women exhibited ovarian vein reflux. In 56 of those 57 individuals, reflux occurred only in the LOV, and in 1 subject, reflux was noted predominantly in the ROV. No significant relationship between the presence of an ROV that drained into the right renal vein and pelvic varices was noted. Conclusion: Although right-sided pelvic varices associated with right ovarian vein drainage variations are rare, anatomic variations of the right ovarian vein are not. This study did not find an association between the presence of right ovarian vein and pelvic varices.

  19. Improving the Effectiveness of a Nutrient Removal System Composed of Microalgae and Daphnia by an Artificial Illumination

    Directory of Open Access Journals (Sweden)

    In-Ho Chang

    2014-03-01

    Full Text Available For determining the effect of illumination on nutrient removal in an artificial food web (AFW system, we launched a pilot continuous-flow system. The system consisted of a storage basin, a phytoplankton growth chamber, and a zooplankton growth chamber. A 25,000 Lux AFW-light emitting diode (LED on system and an AFW-LED off system were separately operated for 10 days. In the AFW-LED on system, the maximum chlorophyll-a concentration of the phytoplankton chamber was four times higher than that of the AFW-LED off system. With artificial nighttime illumination, the microalgae became both smaller and more nutritious; the microalgae became high quality food for the zooplankton, Daphnia magna. Consequently, this zooplankton became more efficient at extracting nutrients and grew more densely than in the AFW-LED off system condition. In the LED-on condition, the amounts of total nitrogen (TN and total phosphorus (TP flowing into the system for 10 days were 84.7 g and 20.4 g, and the amounts flowing out were 19.5 g (23% and 4.0 g (20%, respectively. In contrast, in the LED-off condition, 83.8 g and 20.6 g of TN and TP flowed into the system while 38.8 g (46% and 6.8 g (33% flowed out, respectively. Artificial illumination significantly improves the removal rate of nutrients in an AFW system.

  20. Acute paraumbilical vein recanalization: an unusual complication of acute pancreatitis

    Directory of Open Access Journals (Sweden)

    R J Foster

    2015-04-01

    Full Text Available Acute pancreatitis is associated with a number of well-known complications and imaging findings. Spontaneous recanalization of the paraumbilical veins as a consequence of pancreatitis in a patient with an otherwise normal liver is, however, a rare entity. This case report depicts this unusual complication as a consequence of gallstone pancreatitis in a patient with a non-cirrhotic liver and no clinical or radiological evidence of portal hypertension. There was recanalization of the paraumbilical veins followed by thrombosis, which is believed to have propagated in a retrograde fashion into distal branches of the otherwise patent portal vein. A literature search for similar cases such as this has yielded no results. Although rare, clinicians and radiologists alike need to be aware of this finding. This case discussion highlights the embryology and anatomy of the paraumbilical veins, as well as discusses the management of paraumbilical and portal vein thrombosis.