WorldWideScience

Sample records for artificial atlanto-odontoid joint

  1. Osteoarthritis of the atlanto-odontoid joint

    International Nuclear Information System (INIS)

    Genez, B.M.; Woodruff, W.W.; Laverman, W.C.; Willis, J.J.; Lowrey, C.; Diaz, M.J.

    1989-01-01

    The authors have investigated the incidence and the radiographic and CT findings of atlanto- odontoid degenerative arthrosis. The authors have reviewed 120 cervical spine radiographs for evidence of osteophytes of the atlas and odontoid, correlating these findings with lower cervical spine changes in each patient. Thirty patients also had CT examinations of the craniovertebral junction, permitting determination of sensitivity and specificity of radiographic findings. CT revealed occult changes, such as cysts, paraarticular osteophytes and intraarticular calcifications. Clinical examination in 16 patients showed decreased head rotation, vertigo, and neck and suboccipital pain

  2. Degenerative osteoarthritis of atlanto-odontoid joint: CT findings and clinical analysis

    International Nuclear Information System (INIS)

    Xu Aide; Wang Song; Mao Yunhua

    1998-01-01

    Purpose: To analyze the CT appearances and clinical aspects of the degeneration at atlanto-odontoid(A-O) joint. Methods: Thin section axial CT scans, of AO joints were studied in 317 consecutive patients who underwent brain or cervical spine CT examinations. The images were viewed using double-blind method. Observation included: osteophytosis, changes of joint space and transverse ligament, and the clinical symptoms as well. Results: CT findings of AO joint degeneration included: formation of osteophyte, narrowing of joint space, transverse ligament calcification, and joint vacuum phenomenon. Among individuals above 40 years of age, the incidence of degeneration at AO joint went up gradually (P<0.01). Conclusion: Degeneration of AO joint was not uncommon among aged people, CT could better demonstrate the pathological changes

  3. Laron syndrome abnormalities: spinal stenosis, os odontoideum, degenerative changes of the atlanto-odontoid joint, and small oropharynx.

    Science.gov (United States)

    Kornreich, Liora; Horev, Gadi; Schwarz, Michael; Karmazyn, Boaz; Laron, Zvi

    2002-04-01

    Patients with Laron syndrome have an inborn growth hormone resistance. We investigated abnormalities in the upper airways and cervical spine in patients with Laron syndrome. We prospectively examined 11 patients (one child aged 9 years and 10 adults aged 36-68 years), 10 of whom underwent MR imaging of the spine or head; nine, radiography of the cervical spine; and four, CT of C1-C2. The width of the spinal canal was evaluated visually and quantitatively and compared with reference values. The smallest diameter of the oropharynx and the thickness of the palate were measured and compared with reference values. Nine age-matched female patients referred for MR imaging for unrelated reasons served as control subjects. Cervical spinal stenosis was present in seven of the adult patients, within a confidence interval of 95%. Anomaly of the dens compatible with os odontoideum was present in three patients, causing focal myelomalacia in two. The atlanto-odontoid joint showed osteoarthritic changes in six of the adult patients. The mediolateral diameter of the oropharynx was significantly smaller in the patients with Laron syndrome than in the control subjects (P Laron syndrome develop significant narrowing of the cervical spinal canal and early degenerative changes of the atlanto-odontoid joint. Laron syndrome is associated with os odontoideum causing myelomalacia. The dimensions of the oropharynx are small. Patients may be prone to neurologic morbidity and sleep disturbances. Routine MR imaging of the cervical spine is recommended in these patients.

  4. Relationship between atlanto-odontoid osteoarthritis and idiopathic suboccipital neck pain

    International Nuclear Information System (INIS)

    Zapletal, J.; Hekster, R.E.M.; Straver, J.S.; Wilmink, J.T.; Hermans, J.

    1996-01-01

    We discuss the relationship of atlanto-odontoid (AO) (anterior C1-C2 joint) osteoarthritis to suboccipital pain. A questionnaire regarding suboccipital neck pain was presented to 210 consecutive patients undergoing computed tomography (CT) of the brain or sinuses for a variety of indications. In all patients the AO joint and the lateral scout image of the cervical spine were studied. In 104 (49%) degenerative changes were seen at the AO joint. There were 89 patients (42%) who reported pain in the suboccipital region, although this was not the reason for CT in any patient. Statistical analysis of the prevalence of suboccipital neck pain in all patients showed the presence of AO osteoarthritis seen on CT to be associated with occurrence of these symptoms. This association remained significant in the same study population after excluding patients with a history of rheumatoid arthritis, migraine, stress and neck trauma and patients with signs of degenerative changes of C2-C7 on the computed lateral scout image. (orig.)

  5. Odontoid pannus formation in a patient with ankylosing spondylitis causing atlanto-axial instability

    Science.gov (United States)

    Rajak, Rizwan; Wardle, Phil; Rhys-Dillon, Ceril; Martin, James C

    2012-01-01

    Ankylosing spondylitis is one of the commonest inflammatory diseases of the axial skeleton and can be complicated by atlanto-axial instability. This serious and likely underestimated complication can be easily overlooked. However, there are clear features which can help alert suspicion to initiate the appropriate investigations with imaging that is very effective at diagnosing and assessing this complication. The authors report an unusual case where odontoid pannus formation, akin to that seen in rheumatoid arthritis, was the underlying cause. PMID:22665557

  6. Special examinations in neuroradiology diagnostic of the neurological complications in atlanto axial dislocations

    International Nuclear Information System (INIS)

    Mihale, J.

    1998-01-01

    We report about contribution myelography, CT myelography, vertebral angiography and angio-cinematography, CT and MRI in diagnostic of the neurological complications of the ventral atlanto axial dislocation in 126 patients with progressive polyarthritis and ankylosing spondylarthritis. On the myelogram, and CT myelogram we visualized narrowing of the spinal channel in ventral atlanto axial dislocation. In patients with unreponibile dislocation up to the stop contrast medium between C1 and C2 vertebrae. With vertebral angiography and angio-cinematography we visualized changes in course of the arteries until with stop of the contrast medium in ante-flexion of the head in patients with unreponibile atlanto axial dislocation. On the MRI studies we visualized pathological changes in the front and back of the atlanto odontoidal joints and compression of the spinal cord. (author)

  7. Traumatic atlanto-occipital dissociation presenting as locked-in syndrome.

    Science.gov (United States)

    Desai, Rupen; Kinon, Merritt D; Loriaux, Daniel B; Bagley, Carlos A

    2015-12-01

    We present an unusual presentation of unstable atlanto-occipital dissociation as locked-in syndrome. Traumatic atlanto-occipital dissociation is a severe injury that accounts for 15-20% of all fatal cervical spinal injuries. A disruption occurs between the tectorial ligaments connecting the occipital condyle to the superior articulating facets of the atlas, resulting in anterior, longitudinal, or posterior translation, and it may be associated with Type III odontoid fractures. Furthermore, the dissociation may be complete (atlanto-occipital dislocation) or incomplete (atlanto-occipital subluxation), with neurologic findings ranging from normal to complete quadriplegia with respiratory compromise. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. The investigation of the lateral atlanto-dental interval of atlanto-axial joint by multi-slice spiral CT

    International Nuclear Information System (INIS)

    Cui Wei; Peng Lei; Wang Jincai; Liu Jihua; Feng Weihua

    2010-01-01

    Objective: To explore imaging features of the lateral atlanto-dental interval (LADI) of atlanto-axial joint and its value in the diagnosis of atlanto-axial joint dislocation/subluxation. Methods: Two hundred and forty healthy volunteers without atlanto-axial joint dysfunction and 32 patients with torticollis and/or functional impairment at atlanto-axial.joint were enrolled into this study. All subjects were examined with multi-slice CT in both neutral and max rotation positions to the left/right. Clinical endpoints including VBLADI, variance range of the VBLADI and asymmetric conditions were evaluate. χ 2 test is used to evaluate the variance of incidence of bilateral LADI asymmetry in different age groups, Pearson-test (2-tailed) is used to evaluate the correlation between VBLADI and rotary function of atlanto-axial joint, precise test of fourfold table is used to compare normal group with patient groups. Results: (1) In the normal control group: asymmetry of bilateral LADI were observed in 204 among 240 (85.00%) healthy volunteers including 60 youngsters ( 95% of ∣ VBLADI ∣ were 0.850 mm, 2.450 mm in the young ( 95% in the young and in the adult respectively. There was no correlation between VBLADI(-2.146 to 2.114 mm, Median 0.000 mm) and LA (22.949° to 44.649°, Median 34.500°), RA (25.284° to 45.334°, Median 35.300°), VLRA (-11.643° to 8.623°, median 0.000°) respectively in normal people (r=-0.030, -0.005, 0.026, P>0.05). (2) In the study with 32 patients including 25 youngsters ( 95% in group AALSD and group AACD than in abnormal group (P<0.01), but there is no difference between group AARD and normal group (P=0.738). Conclusion: The imaging finding of 'asymmetry of bilateral LADI' may be either a physiological variation or a pathological condition, clinical manifestations and other imaging findings should be evaluated to make a diagnosis. (authors)

  9. Rotatory Subluxation and Facet Deformity in the Atlanto-occipital Joint in Patients with Chronic Atlantoaxial Rotatory Fixation: Two Case Reports.

    Science.gov (United States)

    Kashii, Masafumi; Masuhara, Kenta; Kaito, Takashi; Iwasaki, Motoki

    2017-01-01

    The relationship between the morphometry of atlantoaxial joint and chronic atlantoaxial rotatory fixation (AARF) is well known, but disorders in the atlanto-occipital joint in chronic AARF are not fully elucidated. The authors report two rare cases of secondary deformities in the atlanto-occipital joint in chronic AARF. Two patients with chronic AARF were treated with closed manipulation, skull traction and halo-vest immobilization. Clinical outcomes and radiographs were reviewed retrospectively, focusing on pathological changes in the atlanto-occipital joint using multiplanar reconstruction computed tomography and three-dimensional computed tomography images. Case 1 (12-year-old girl) had rotatory subluxation with a superior facet deformity of the atlas in the atlanto-occipital joint before the initiation of treatment. After a series of conservative treatments, both atlantoaxial and atlanto-occipital rotatory fixation could not be reduced, and both the superior facet deformity of the atlas and osteoarthritic changes in the atlanto-occipital developed. She was monitored without surgery because the disorder progressed to the spontaneous fusion of the occipital bone to the axis. Case 2 (13-year-old boy) had rotatory subluxation without facet deformity of the atlas in the atlanto-occipital joint before the initiation of treatment. However, both the superior facet deformity of the atlas and osteoarthritic changes in the atlanto-occipital developed over time, and both atlantoaxial and atlanto-occipital rotatory fixation could not be reduced after a series of conservative treatments. He still had severe neck pain and severely restricted neck mobility and underwent spinal fusion. Atlanto-occipital rotatory subluxation and facet deformity in the atlanto-occipital joint may occur after prolonged AARF. It is necessary to pay attention to pathological changes not only in the atlantoaxial joint but also in the atlanto-occipital joint, when orthopedic surgeons treat patients

  10. Acute neck pain caused by arthritis of atlanto-axial joint

    International Nuclear Information System (INIS)

    Kobayashi, Takashi; Ishikawa, Yoshinori; Abe, Eiji; Konno, Norikazu; Noguchi, Hideaki

    2009-01-01

    We reviewed 27 cases in which the patient complained of acute neck pain. We had performed arthrocentesis of the atlanto-axial joint in every case. An aspirate was obtained in 16 of the cases, and calcium pryophosphate dihydrate (CPPD) crystals were demonstrated in 10 of them. The patients' scores on the visual analogue scale decreased 30 minutes after aspiration of the crystals (p<0.001). CT demonstrated calcification of the transverse ligament in 22 cases, calcification anterior to the body of C2 in 2 cases, and no calcification in 3 cases. The results in these patients suggest that acute neck pain in some elderly patients is related to arthritis of the atlanto-axial joint. (author)

  11. Condylar Joint Fusion and Stabilization (by Screws and Plates) in Nontraumatic Atlanto-Occipital Dislocation: Technical Report of 2 Cases.

    Science.gov (United States)

    Chowdhury, Forhad H; Haque, Mohammod Raziul; Alam, Sarwar Murshed; Khaled Chowdhury, S M Noman; Khan, Shamsul Islam; Goel, Atul

    2017-11-01

    Nontraumatic spontaneous atlanto-occipital dislocation (AOD) is rare. In this report, we discuss the technical steps of condylar joint fusion and stabilization (by screws and plates) in nontraumatic AOD. To the best of our knowledge, it is the first report of such techniques. A young girl and a young man with progressive quadriparesis due to nontraumatic spontaneous atlanto-occipital dislocation were managed by microsurgical reduction, fusion, and stabilization of the joint by occipital condylar and C1 lateral mass screw and plate fixation after mobilization of vertebral artery. In both cases, condylar joints fixation and fusion were done successfully. Condylar joint stabilization and fusion may be a good or alternative option for AOD. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Condylus tertius with atlanto-axial rotatory fixation: an unreported association

    International Nuclear Information System (INIS)

    Udare, Ashlesha Satish; Bansal, Divya; Patel, Bhavin; Mondel, Prabath Kumar; Aiyer, Siddharth

    2014-01-01

    The ''condylus tertius'' or the ''third occipital condyle'' is an embryological remnant of the proatlas sclerotome. Anatomically, it is attached to the basion and often articulates with the anterior arch of the atlas and the odontoid apex; hence, it is also called the ''median occipital condyle''. It is a rare anomaly of the cranio-vertebral junction (CVJ) that can lead to instability and compression of important surrounding neurovascular structures. We report a case of a 16-year-old boy who presented with suboccipital neck pain, torticollis and right sided hemiparesis. Plain radiographs revealed an increased atlanto-dental interspace (ADI) with a retroflexed odontoid. Open mouth view showed asymmetry of the articular processes of the atlas with respect to the dens. Computed tomography (CT) of the CVJ delineated the third occipital condyle. Furthermore, on dynamic CT study, a type 3 atlanto-axial rotatory fixation (AARF) was clearly demonstrated. Magnetic resonance imaging (MRI) of the CVJ revealed severe right-sided spinal cord compression by the retroflexed and rightward deviated dens. It also revealed disruption of the left alar and transverse ligaments. The patient was treated with 8 weeks of cranial traction and reasonable alignment was obtained. This was followed by C1-C2 lateral mass screw fixation and C1-C2 interlaminar wiring to maintain the alignment. A review of the literature did not reveal any cases of condylus tertius associated with non-traumatic AARF. An accurate knowledge of the embryology and imaging features of this rare CVJ anomaly is useful in the prompt diagnosis and management of such patients. (orig.)

  13. Imaging of childhood torticollis due to atlanto-axial rotatory fixation.

    Science.gov (United States)

    Maheshwaran, S; Sgouros, S; Jeyapalan, K; Chapman, S; Chandy, J; Flint, G

    1995-12-01

    Atlanto-axial rotatory fixation is a rare cause of childhood torticollis. It may occur spontaneously or may be associated with trauma, upper respiratory tract infection or congenital abnormality of the cervical spine. Presentation is usually with persistent torticollis and "cock robin" deformity of the neck. In this paper the radiological experience in three patients is presented. Investigations included plain radiographs, plain anteroposterior tomography, CT and MRI. Displacement of the lateral mass of the atlas and the eccentric position of the odontoid peg can be seen in the plain films. CT scan can exclude fractures and confirm atlanto-axial rotation. The superimposition of CT images is demonstrated as a way of diagnosing subluxation. MRI offers better soft tissue differentiation and allows assessment of the integrity of the transverse ligament. This has an important bearing on the prognosis and may influence surgical treatment. It is important to recognise the plain film features of this uncommon condition and confirm the diagnosis with CT or MRI. The treatment options are discussed with particular reference to long term outcome.

  14. Condylus tertius with atlanto-axial rotatory fixation: an unreported association

    Energy Technology Data Exchange (ETDEWEB)

    Udare, Ashlesha Satish [M.G.M. Hospital, Department of Radiology, Kamothe, Navi Mumbai (India); Global Hospital Super Speciality and Transplant Centre, Department of Radiology, Mumbai (India); Navi Mumbai, Maharashtra (India); Bansal, Divya; Patel, Bhavin [M.G.M. Hospital, Department of Radiology, Kamothe, Navi Mumbai (India); Mondel, Prabath Kumar [P.D. Hinduja Hospital, Department of Radiology, Mahim, Mumbai (India); Aiyer, Siddharth [Shatabdi Hospital, Department of Orthopedics, Chembur, Mumbai (India)

    2014-04-15

    The ''condylus tertius'' or the ''third occipital condyle'' is an embryological remnant of the proatlas sclerotome. Anatomically, it is attached to the basion and often articulates with the anterior arch of the atlas and the odontoid apex; hence, it is also called the ''median occipital condyle''. It is a rare anomaly of the cranio-vertebral junction (CVJ) that can lead to instability and compression of important surrounding neurovascular structures. We report a case of a 16-year-old boy who presented with suboccipital neck pain, torticollis and right sided hemiparesis. Plain radiographs revealed an increased atlanto-dental interspace (ADI) with a retroflexed odontoid. Open mouth view showed asymmetry of the articular processes of the atlas with respect to the dens. Computed tomography (CT) of the CVJ delineated the third occipital condyle. Furthermore, on dynamic CT study, a type 3 atlanto-axial rotatory fixation (AARF) was clearly demonstrated. Magnetic resonance imaging (MRI) of the CVJ revealed severe right-sided spinal cord compression by the retroflexed and rightward deviated dens. It also revealed disruption of the left alar and transverse ligaments. The patient was treated with 8 weeks of cranial traction and reasonable alignment was obtained. This was followed by C1-C2 lateral mass screw fixation and C1-C2 interlaminar wiring to maintain the alignment. A review of the literature did not reveal any cases of condylus tertius associated with non-traumatic AARF. An accurate knowledge of the embryology and imaging features of this rare CVJ anomaly is useful in the prompt diagnosis and management of such patients. (orig.)

  15. Atlanto-Occipital Rotatory Dislocation: A Case Report and Systematic Review.

    Science.gov (United States)

    Robles, Luis A; Mundis, Greg M; Cuevas-Solórzano, Abel

    2018-02-01

    Atlanto-occipital rotatory dislocation (AORD) has rarely been reported in the literature; for this reason, the clinicoradiologic characteristics of this injury are not well described. We describe the case of a 67-year-old man who sustained a cervical spine trauma. He reported only neck pain and was neurologically intact. A computed tomography scan showed a rotatory displacement of the atlanto-occipital joints associated with a widened condylar-C1 interval; in addition, magnetic resonance imaging showed injuries to the stabilizing ligaments of this area. A systematic literature review was also performed to identify previous cases of patients with AORD. The patient was treated with craniocervical fixation from occipital to C1, achieving a good outcome. The literature review yielded 9 cases of patients with AORD. Compared with patients with atlanto-occipital dislocation, patients with rotatory dislocations have a less severe degree of displacement of the atlanto-occipital joints and better clinical outcome. Compared with previously classified atlanto-occipital dislocations, AORD is an independent and unique variation. AORD presents with different biomechanical, clinicoradiologic, and prognostic characteristics and represents an important addition to the spectrum of atlanto-occipital dislocation injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Posterior atlanto-occipital and atlanto-axial area and its surgical interest

    Directory of Open Access Journals (Sweden)

    Newton José Godoy Pimenta

    2014-10-01

    Full Text Available Classic anatomical studies describe two membranes – atlanto-occipital and atlanto-axial in the posterior aspect of the craniocervical region. During many surgical procedures in this area, however, we have not found such membranes. Objective To clarify the anatomical aspects and structures taking part of the posterior atlanto-occipital and atlanto-axial area. Method Analysis of histological cuts of three human fetuses and anatomical studies of 8 adult human cadavers. Results In both atlanto-occipital and atlanto-axial areas, we have observed attachment between suboccipital deep muscles and the spinal cervical dura. However, anatomical description of such attachments could not be found in textbooks of anatomy. Conclusion Our study shows the absence of the classical atlanto-occipital and atlanto-axial membranes; the occipito-C1 and C1-C2 posterior intervals are an open area, allowing aponeurotic attachment among cervical dura mater and posterior cervical muscles.

  17. Progressive atlanto-axial subluxation in Behcet's disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang-hyuk [Chonbuk National University Hospital, Department of Neurosurgery, Jeonju City, Jeonbuk (Korea); Eoh, Whan [Sungkyunkwan University School of Medicine, Samsung Medical Center, Department of Neurosurgery, Seoul (Korea)

    2010-03-15

    Behcet's disease is a chronic inflammatory condition involving several organs, such as the skin, mucous membranes, eyes, joints, intestines, lungs and central nervous system. It rarely affects the spinal column. We describe a case of progressive atlanto-axial subluxation in a 44-year-old woman with Behcet's disease. The patient started complaining of posterior neck pain 10 years after the diagnosis of her Behcet's disease. Initial radiographs showed no abnormal finding, but follow-up radiographs 6 month later demonstrated atlanto-axial subluxation. To the best of our knowledge, this is the second reported case in the worldwide literature of an atlanto-axial instability in a patient with Behcet's disease. (orig.)

  18. Lateral atlanto-axial joint block for cervical headache

    Directory of Open Access Journals (Sweden)

    Shantanu P Mallick

    2013-01-01

    Full Text Available The patient is a 32-year-old car mechanic, having chronic headache for three years affecting the left upper lateral part of the neck, suboccipital region, and scalp (VAS: 8/10, having a history of whiplash injury from a car accident three years ago, with a deep cut injury on the scalp. He was complaining of neck stiffness and pain during all neck movements and a burning pain in the entire left side of the neck and scalp. He was treated, using conservative methods, by Orthopedists, Neurologists, as well as Psychiatrists, and all investigations including computed tomography (CT of the brain, X-ray cervical spine, and all related blood reports were within normal limits. He was sent to the Pain Clinic for further assessment. Suspecting sympathetic mediated pain on the left side and upper cervical facet pain, he was given a diagnostic Stellate Ganglion Block, a Third Occipital Nerve block, and a fourth cervical medial branch block (MBB, which gave him good relief; by this the visual analog scale (VAS score reduced to 3/10. Yet, he was complaining of pain on a focal area on the left upper cervical spine corresponding to the C1-2 joint with lateral rotation on the left side. Subsequently it was decided that a diagnostic Atlanto-axial joint block under fluoroscopy would be carried out. This gave him very good relief from the cervicogenic headache.

  19. Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture

    OpenAIRE

    Wu, Ai-Min; Jin, Hai-Ming; Lin, Zhong-Ke; Chi, Yong-Long; Wang, Xiang-Yang

    2017-01-01

    Background The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Methods Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 trans...

  20. The helical three-dimensional CT in the diagnosis of torticollis with occipitocondylar hypoplasia

    International Nuclear Information System (INIS)

    Ilkko, E.; Tikkakoski, T.; Pyhtinen, J.

    1998-01-01

    Congenital anomalies of the atlanto-occipital and atlantoaxial joints are rare. Those most commonly reported are atlantoaxial instability, basilar impression, anomalies of the odontoid process, laxity of the transverse atlantal ligament and atlanto-occipital fusion. Occipital condylar hypoplasia is infrequent and difficult to recognise. We recently diagnosed it using helical 3D CT in association with torticollis in two patients. The first patient had a several year history of torticollis. The second patient had acute cervical lymphadenitis associated with post-operative torticollis. 3D CT distinctly revealed atlantoaxial subluxation with hypoplasia of the occipital condyles in both cases

  1. Clinical and Radiographic Outcomes of C1 Laminectomy Without Fusion in Patients With Cervical Myelopathy That Is Associated With a Retro-odontoid Pseudotumor.

    Science.gov (United States)

    Takemoto, Mitsuru; Neo, Masashi; Fujibayashi, Shunsuke; Sakamoto, Takeshi; Ota, Masato; Otsuki, Bungo; Kaneko, Hiroki; Umebayashi, Takeshi

    2016-12-01

    A retro-odontoid pseudotumor that is not associated with rheumatoid arthritis or hemodialysis is clinically rare. The majority of surgeons select transoral resection as the surgical treatment, often followed by posterior fusion or posterior decompression and fusion. In contrast, some authors have reported success with simple decompression without posterior stabilization in cases where atlanto-axial instability (AAI) is either absent or minor. In this study, we have evaluated the clinical and radiographic outcomes of C1 laminectomy without fusion as the surgical treatment for patients with cervical myelopathy that is associated with a retro-odontoid pseudotumor. A retrospective chart review was conducted on 10 patients who underwent C1 laminectomy without fusion for cervical myelopathy associated with a retro-odontoid pseudotumor. The average follow-up time was 29 months. All cases were graded as Ranawat grade 3a or 3b. After surgery, myelopathy improved in all of the patients. In 2 patients, the atlas-dens interval increased in the flexed position; however, this did not result in any clinical problems. The size of the retro-odontoid mass (measured on magnetic resonance images at least 12 mo after surgery) decreased in 4 of the 10 cases. AAI progression and mass enlargement were our primary concerns for this surgical option; however, C1 laminectomy did not cause severe AAI progression, no patients showed serious mass enlargement, and all patients demonstrated neurological improvement. This surgical strategy is beneficial especially for elderly patients given the risks of other surgical options that use an anterior transoral approach or posterior fusion.

  2. The internal vertebral venous plexus prevents compression of the dural sac during atlanto-axial rotation

    Energy Technology Data Exchange (ETDEWEB)

    Reesink, E.M.; Lataster, L.M.A.; Mameren, H. van [Dept. of Anatomy/Embryology, Maastricht Univ. (Netherlands); Wilmink, J.T. [Dept. of Radiology, University Hospital Maastricht (Netherlands); Kingma, H. [Dept. of ENT, University Hospital Maastricht (Netherlands)

    2001-10-01

    Deformation of the extradural space and the possibility of impression upon the dural sac during atlanto-axial rotation are investigated. Atlanto-axial rotation leads to a reduction in the cross-sectional area of the bony spinal canal of approximately 40 %. Atlanto-axial rotation was recorded by endocanalar views from a video camera fixed inside the skull of six unembalmed cadavers. Axial thin-section T1-weighted MRI slice sets were acquired from three volunteers (mid-position and maximal left and right rotation of the head and cervical spine). The axial cross-sectional areas of the bony spinal canal, dural sac and spinal cord were measured. In two other persons post-gadolinium contrast-enhanced T1-weighted MRI volume scans with fat-suppression prepulse were acquired (mid-position and rotation) to determine venous contents of the extradural space. The 50:50 ratio between left and right extradural halves in mid-position changed to an ipsilateral:contralateral ratio of 20:80 in maximum rotation at the level just above the lateral C1-C2 joints. Directly below these joints the opposite occurred. The post-contrast studies showed an enhancing internal vertebral venous plexus (IVVP), which almost completely occupied the extradural space at the atlanto-axial level. This could not be shown in the cadaver experiments, because of absence of blood and cerebrospinal fluid (CSF) pressure. During atlanto-axial rotation blood displacement in the IVVP allows major deformations of the extradural space. This prevents dural sac impression. (orig.)

  3. The helical three-dimensional CT in the diagnosis of torticollis with occipitocondylar hypoplasia

    International Nuclear Information System (INIS)

    Ilkko, E.; Tikkakoski, T.; Pyhtinen, J.

    1998-01-01

    Congenital anomalies of the atlanto-occipital and atlantoaxial joints are rare. Those most commonly reported are atlantoaxial instability, basilar impression, anomalies of the odontoid process, laxity of the transverse atlantal ligament and atlanto-occipital fusion. Occipital condylar hypoplasia is infrequent and difficult to recognise. We recently diagnosed it using helical 3D CT in association with torticollis in two patients. The first patient had a several year history of torticollis. The second patient had acute cervical lymphadenitis associated with post-operative torticollis. 3D CT distinctly revealed atlantoaxial subluxation with hypoplasia of the occipital condyles in both cases. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  4. Odontoid fractures: A retrospective analysis of 53 cases

    Directory of Open Access Journals (Sweden)

    Shetty Arjun

    2009-01-01

    Full Text Available Background: The management of odontoid fracture has evolved but controversy persists as to the best method for Type II odontoid fractures with or without atlantoaxial (AA instability. The anterior odontoid screw fixation can be associated with significant morbidity while delayed odontoid screw fixation has shown to be associated with reasonable good fusion rates. We conducted a retrospective analysis to evaluate the outcome of a trial of conservative management in type II odontoid fractures without atlantoaxial instability (Group A followed by delayed odontoid screw fixation in cases in which fusion was not achieved by conservative treatment. The outcome of type II odontoid fracture with AA subluxation (Group B was also analysed where closed reduction on traction could be achieved and in those atlantoaxial subluxations that were irreducible an intraoperative reduction was done. Materials and Methods: A retrospective evaluation of 53 cases of odontoid fractures treated over a 9-year period is being reported. All odontoid fractures without AA instability (n=29 were initially managed conservatively. Three patients who did not achieve union with conservative management were treated with delayed anterior screw fixation. Twenty-four cases of odontoid fractures were associated with AA instability; 17 of them could be reduced with skeletal traction and were managed with posterior fusion and fixation. Of the seven cases that were irreducible, the initial three cases were treated by odontoid excision followed by posterior fusion and fixation; however, in the later four cases, intra operative reduction was achieved by a manipulation procedure, and posterior fusion and fixation was performed. Results: Twenty-six of 29 cases of odontoid fracture without AA instability achieved fracture union with conservative management whereas the remaining three patients achieved union following delayed anterior odontoid screw fixation. 17 out of 24 odontoid fracture with

  5. Usefulness of MRI in the diagnosis of atlanto-axial dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Ko; Fukui, Keiji; Sadamoto, Kazuhiko; Miki, Hitoshi; Niida, Akira; Sakaki, Saburo.

    1988-08-01

    We studied 14 cases of atlanto-axial dislocation (AAD) by means of a 0.5 Tesla superconductive magnetic resonance imaging (MRI) system using saturation recovery sequences (Tr: 500 msec, Te: 20 - 30 msec) with a 5 - 10 mm slice thickness, and directly evaluated the degree of the spinal-cord compression in flexion, neutral, and extension of the head on the midsagittal images. The patients ranged from 11 to 76 years of age, and 8 of the 14 were male. In all cases we could demonstrate the cord compression in various degrees by either the odontoid process or the posterior arch of the atlas. The spinal cords were compressed from ventral in flexion in 6 cases, from dorsal in flexion in 2 cases, from dorsal in extension in 2 cases, and from ventral in both flexion and extension in 2 cases each. In addition, syringomyelia could be revealed by MRI in combination with AAD in 2 cases. MRI is useful in revealing the direction and degree of spinal-cord compression in patients with AAD, and in evaluating combined diseases such as syringomyelia and Arnold-Chiari malformations.

  6. Zygomatic arch-atlas wing stabilization in 5 dogs with atlanto-occipital dislocation.

    Science.gov (United States)

    Dolera, Mario; Malfassi, Luca; Bianchi, Cristina; Carrara, Nancy; Corbetta, Laura; Finesso, Sara; Marcarini, Silvia; Mazza, Giovanni; Pavesi, Simone; Sala, Massimo

    2016-07-01

    The aim of this work was to present a novel minimally invasive surgical stabilization technique for canine atlanto-occipital dislocation and to report the associated magnetic resonance imaging (MRI) findings. All 5 dogs in this case series underwent 1.5 T MRI of the head and neck and 3 underwent both MRI and computed tomography (CT). Atlanto-occipital dislocations were diagnosed based on the increased joint space between the occipital condyles and the atlas on MRI. Surgery was performed immediately with a never previously described fixation technique based on an external ligature. The stabilization was performed via 4 holes drilled in the zygomatic processes and in the atlas wings on each side. A nylon monofilament of 1 mm diameter was inserted in the 4 holes, and an O-shaped ligature was carried out externally to the skin through the ipsilateral zygomatic arch. Ligatures were removed within 2 months. At the postsurgical follow-up examination, 14 days after surgery, all dogs were found to be ambulatory. Atlanto-occipital stability was assessed by clinical examination with an average of 24 months of follow-up. The positive outcomes in this case series suggest that atlanto-occipital dislocation may be surgically treated with this novel technique, irrespective of the severity of the clinical presentation and associated lesions observed on MRI.

  7. Dorsal surgical stabilisation using tension bands for treatment of traumatic atlanto-occipital instability in a cat.

    Science.gov (United States)

    Vedrine, B; Maurin, M P

    2017-12-01

    An atlanto-occipital instability secondary to a dog bite was diagnosed in a 4-year-old Persian cat. Dorsal stabilisation of the instability was made with two OrthoFiber prostheses (Securos), which were used as tension bands between the nuchal crests of the occipital bone and the spinous process of the axis. Total recovery was achieved 4 days after surgery. Normal alignment of the atlanto-occipital joint was observed on survey radiographs taken 6 weeks post-surgery. Although the right loop had failed, the alignment was still normal and no neurological after-effects could be identified. Dorsal divergent tension bands between the nuchal crests of the occipital bone and the spinous process of the axis can be used to stabilise traumatic atlanto-occipital instability. © 2017 Australian Veterinary Association.

  8. Spinal movement and dural sac compression during airway management in a cadaveric model with atlanto-occipital instability.

    Science.gov (United States)

    Liao, Shiyao; Schneider, Niko R E; Weilbacher, Frank; Stehr, Anne; Matschke, Stefan; Grützner, Paul A; Popp, Erik; Kreinest, Michael

    2017-12-01

    To analyze the compression of the dural sac and the cervical spinal movement during performing different airway interventions in case of atlanto-occipital dislocation. In six fresh cadavers, atlanto-occipital dislocation was performed by distracting the opened atlanto-occipital joint capsule and sectioning the tectorial membrane. Airway management was done using three airway devices (direct laryngoscopy, video laryngoscopy, and insertion of a laryngeal tube). The change of dural sac's width and intervertebral angulation in stable and unstable atlanto-occipital conditions were recorded by video fluoroscopy with myelography. Three-dimensional overall movement of cervical spine was measured in a wireless human motion track system. Compared with a mean dural sac compression of - 0.5 mm (- 0.7 to - 0.3 mm) in stable condition, direct laryngoscopy caused an increased dural sac compression of - 1.6 mm (- 1.9 to - 0.6 mm, p = 0.028) in the unstable atlanto-occipital condition. No increased compression on dural sac was found using video laryngoscopy or the laryngeal tube. Moreover, direct laryngoscopy caused greater overall extension and rotation of cervical spine than laryngeal tube insertion in both stable and unstable conditions. Among three procedures, the insertion of a laryngeal tube took the shortest time. In case of atlanto-occipital dislocation, intubation using direct laryngoscopy exacerbates dural sac compression and may cause damage to the spinal cord.

  9. Atlanto-axial malformation and instability in dogs with pituitary dwarfism due to an LHX3 mutation.

    Science.gov (United States)

    Voorbij, A M W Y; Meij, B P; van Bruggen, L W L; Grinwis, G C M; Stassen, Q E M; Kooistra, H S

    2015-01-01

    Canine pituitary dwarfism or combined pituitary hormone deficiency (CPHD) in shepherd dogs is associated with an LHX3 mutation and can lead to a wide range of clinical manifestations. Some dogs with CPHD have neurological signs that are localized to the cervical spine. In human CPHD, caused by an LHX3 mutation, anatomical abnormalities in the atlanto-axial (C1-C2) joint have been described. To evaluate the presence of atlanto-axial malformations in dogs with pituitary dwarfism associated with an LHX3 mutation and to investigate the degree of similarity between the atlanto-axial anomalies found in canine and human CPHD patients with an LHX3 mutation. Three client-owned Czechoslovakian wolfdogs and 1 client-owned German shepherd dog, previously diagnosed with pituitary dwarfism caused by an LHX3 mutation, with neurological signs indicating a cervical spinal disorder. Radiography, computed tomography, and magnetic resonance imaging of the cranial neck and skull, necropsy, and histology. Diagnostic imaging identified abnormal positioning of the dens axis and incomplete ossification of the suture lines between the ossification centers of the atlas with concurrent atlanto-axial instability and dynamic compression of the spinal cord by the dens axis. The malformations and aberrant motion at C1-C2 were confirmed at necropsy and histology. The atlanto-axial abnormalities of the dwarf dogs resemble those encountered in human CPHD patients with an LHX3 mutation. These findings suggest an association between the LHX3 mutation in dogs with CPHD and atlanto-axial malformations. Consequently, pituitary dwarfs should be monitored closely for neurological signs. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Internal Medicine.

  10. Management of Odontoid Fracture in Elderly

    Directory of Open Access Journals (Sweden)

    Muhammad Nadeem

    2014-03-01

    Full Text Available Odontoid type II fractures are associated with high mortality in the elderly. Their management can be done either conservatively or surgically, however, surgical treatment is technically demanding and relatively new. We report a case of 75 years old man who presented to our clinical setting, following a history of fall. The CT scan and MRI showed odontoid type II fracture. With time, the neurological deficit got marked and he underwent transoral odontoidectomy and occipitocervical fixation using rods and screws via posterior approach. Patient’s neurological condition improved dramatically and on the short term follow up, he had no motor deficit. Our experience suggests that occipitocervical fixation via posterior approach is a viable option for the management of odontoid type II fracture in the geriatric population.

  11. Mandibular condylar fractures and acute atlanto-axial subluxation Part 2 A physiopathological factor for the cervical spine sprain.

    Science.gov (United States)

    Cutilli, T; Corbacelli, A

    2009-05-01

    The aim of this study was to analyze the physiopathology of the acute cervical injure in the event of mandibular condylar fractures. As in the Part 1, 25 non-consecutive cases of condylar mandibular fractures (16 males and 9 females, mean age: 22.96/range 14-36 years) observed and treated in the Maxillofacial Surgery Department of the University of L'Aquila, have been studied. Types of fractures examined included: unilateral: 19 cases (solitary: 12; associated with other mandibular fractures: 7, homolateral: 2); bilateral: 6 cases (equivalent: 2, not equivalent: 4). A control group was constituted of 10 patients, 5 males and 5 females, aged from 19 to 24 years (mean range: 21.6) suffering from acute isolated cervical distorsion (whiplash). The study has been performed by means of the analysis of X-ray and computed tomography (CT)-CT/3D of the mandibular condylar regions, the occipital-atlanto-axial structures and the cervical region. In all the patients the following constant alterations that link up with these fractures have been observed: the rotation of atlas, the atlanto-axial subluxation and the derangement of the occipital-atlanto-epistropheal joint, homolateral to the side of the mandibular condylar fracture. The cervical spine shows the constant loss of physiological lordosis with hinge between C3 and C4. In the whiplash, as the authors have been able to assess in the control group, there are no alterations of occipital-atlanto-axial joint and the kinetic vector is placed on the longitudinal plane. In the mandibular condylar fractures the kinetic mechanism is completely different regarding the whiplash. The point of entry is the chin and the kinetic vector is oriented down-up, sometimes oblique in the opposite side. Subsequently the kinetic force is transmitted throughout the mandibular structure and causes the condylar or bicondylar fracture. The kinetic vector is placed before on the vertical plane, then on the horizontal plane and later on the vertical

  12. Atlanto-axial Subluxation in rheumatoid arthritis: description of a case

    International Nuclear Information System (INIS)

    Medina, Yimy F; Martinez V, Jose B; Restrepo, Jose Felix; Rondon H, Federico; Iglesias G, Antonio

    2004-01-01

    The damage of the spine by rheumatoid arthritis is multiple and a variety of affectations have been described at cervical level, being the anterior atlanto-axial subluxation and vertical subluxation the more common. However the posterior atlanto-axial subluxation has been rarely described. In this paper, we describe the case of a patient with posterior atlanto-axial subluxaction in addition to its infrequent manifestation of alteration of the lower cranial nerves as a manifestation of myelopathy

  13. Application of Normative Occipital Condyle-C1 Interval Measurements to Detect Atlanto-Occipital Injury in Children.

    Science.gov (United States)

    Corcoran, B; Linscott, L L; Leach, J L; Vadivelu, S

    2016-05-01

    Prior studies have found that widening or asymmetry of the occipital condyle-C1 interval on CT is a sensitive and specific marker for atlanto-occipital dislocation. Previously reported abnormal occipital condyle-C1 interval values are not age-specific, possibly leading to false-positive findings in younger children, in whom this joint space is normally larger than that in adults. This study assesses the utility of applying age-specific normative occipital condyle-C1 interval ranges to documented cases of atlanto-occipital injury compared with previously reported abnormal cutoff values. Retrospective review of CT and MR imaging of 14 subjects with atlanto-occipital injury was performed, and occipital condyle-C1 interval measurements were made for each subject. Sensitivities and specificities of proposed occipital condyle-C1 interval cutoffs of 2 and 3 SDs above the mean and previously published occipital condyle-C1 interval cutoffs for atlanto-occipital injury were then calculated on the basis of occipital condyle-C1 interval measurements for each subject. An occipital condyle-C1 interval 2 SDs above the age-specific mean has a sensitivity of 50% and specificity of 89%-100%, depending on the age group. An occipital condyle-C1 interval 3 SDs above the age-specific mean has a sensitivity of 50% and a specificity of 95%-100%. A 4.0-mm occipital condyle-C1 interval has a sensitivity of 36% and a specificity of 100% in all age groups. A 2.5-mm occipital condyle-C1 interval has a sensitivity of 93% and a specificity of 18%-100%. Occipital condyle-C1 interval widening cutoffs used to establish atlanto-occipital injury lack both sensitivity and specificity in children and young teenagers. MR imaging is necessary to establish a diagnosis of atlanto-occipital injury in children and young teenagers when the appropriate mechanism of injury is present. © 2016 by American Journal of Neuroradiology.

  14. [Odontoid bending stiffness after anterior fixation with a single lag screw: biomechanical study].

    Science.gov (United States)

    Buchvald, P; Čapek, L; Barsa, P

    2015-01-01

    PURPOSE OF THE STUDY The aim of the experiment was to compare the bending stiffness of an intact odontoid process with bending stiffness after its simulated type II fracture was fixed with a single lag screw. The experiment was done with a desire to answer the question of whether a single osteosynthetic screw is sufficient for good fixation of a type II odontoid fracture. MATERIAL AND METHODS The C2 vertebrae of six cadavers were used. With simultaneous measurement of odontoid bending stiffness, the occurrence of a fracture (type IIA, Grauer's modification of the Anderson- D'Alonzo classification) was simulated using action exerted by a tearing machine in the direction perpendicular to the odontoid axis. Each odontoid fracture was subsequently treated by direct osteosynthesis with a single lag screw inserted in the axial direction by a standard surgical procedure in order to provide conditions similar to those achieved by routine surgical management. The treated odontoid process was subsequently subjected to the same tearing machine loading as applied to it at the start of the experiment. The bending stiffness measured was then compared with that found before the fracture occurred. The results were statistically evaluated by the t-test for paired samples at the level of significance α = 0.05. RESULTS The average value of bending stiffness for odontoid processes of intact vertebrae at the moment of fracture occurrence was 318.3 N/mm. After single axial lag screw fixation of the fracture, the average bending stiffness for the odontoid processes treated was 331.3 N/mm. DISCUSSION Higher values of bending stiffness after screw fixation were found in all specimens and, in comparison with the values recorded before simulated fractures, the increase was statistically significant. CONCLUSIONS The results of our measurements suggest that the single lag screw fixation of a type IIA odontoid fracture will provide better stability for the fracture fragment-C2 body complex on

  15. Post-mortem CT evaluation of atlanto-occipital dissociation.

    Science.gov (United States)

    Madadin, Mohammed; Samaranayake, Ravindra Priyalal; O'Donnell, Chris; Cordner, Stephen

    2017-02-01

    Atlanto-occipital dissociation injury is an important injury in forensic pathology practice. Radiological diagnosis of atlanto-occipital dissociation clinically is assessed by direct measurement of occipito-vertebral skeletal relationships. Different measurements may be used to diagnose atlanto-occipital dissociation, including the basion-dens interval (BDI) and basion-axial interval (BAI). It is not known whether the normal ante-mortem measurements of BDI and BAI described in the literature are applicable to post-mortem CT images of the occipito-cervical junction (OCJ) or whether these measurements could be affected by early post-mortem changes. This study aims to compare post-mortem BDI and BAI measurements with ante-mortem values. Post-mortem CT scans of the cervical spines of 100 deceased adults were reviewed, and the BDI and BAI were measured. Different parameters were recorded in each case. The results from this study suggest that there are no effects of post-mortem changes on the measurement of BAI as relied upon clinically. There appear to be some effects of fully established rigor mortis on BDI measurement, shortening it. This may have consequences for the post mortem diagnosis of atlanto-occipital dissociation. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  16. CT and MR imaging of odontoid abnormalities: A pictorial review

    Directory of Open Access Journals (Sweden)

    Nishchint Jain

    2016-01-01

    Full Text Available Odontoid process is the central pillar of the craniovertebral junction. Imaging of this small structure continues to be a challenge for the radiologists due to complex bony and ligamentous anatomy. A wide range of developmental and acquired abnormalities of odontoid have been identified. Their accurate radiologic evaluation is important as different lesions have markedly different clinical course, patient management, and prognosis. This article seeks to provide knowledge for interpreting appearances of odontoid on computed tomography (CT and magnetic resonance imaging (MRI with respect to various disease processes, along with providing a quick review of the embryology and relevant anatomy.

  17. Lateralized odontoid in plain film radiography. Sign of fractures? A comparison study with MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Keller, S.; Bieck, K.; Karul, M.; Schoennagel, B.; Adam, G.; Habermann, C.; Yamamura, J. [University Hospital Hamburg Eppendorf (Germany). Dept. of Diagnostic and Interventional Radiology

    2015-09-15

    To evaluate X-ray standards for the detection of odontoid fractures. Summary of background data: Cervical spine fractures are a common finding in emergency medicine, accounting for 1 - 3 % of injuries. Involvement of the C1 / C2 complex is found in 25 % of cases, affecting the odontoid peg in 55 - 80 %. Regarding the consequences of missed fractures, radiographic techniques built the groundwork for further treatment procedures. As standardized X-ray measurements have not been established, the incidence of unrecognized cervical spine fracture is expected to be up to 20 %. The establishment of X-ray-based guidelines is also limited by the presumed low specificity and sensitivity of distance measurements caused by rotational distortion which leads to a rising popularity of CT. 79 (age 60 ± 26 yrs) patients with lateralization of the odontoid process on conventional plain film radiography (anteroposterior, lateral, and open mouth odontoid process view projection) were examined. The distance between the odontoid process and lateral mass of C1, angles of vertical odontoid line and basis of C2 were measured in the ap view. In the lateral view, dorsal alignment and atlantodental distance were assessed. MDCT examinations were used as a reference. Discriminatory power test was applied to assess significance. 8/79 (10.1 %) odontoid process fractures were found. Diagnosis was achieved on conventional radiographs in 6 patients. Neither distance and angle measurements between odontoid and C1 nor the dorsal alignment of the vertebral bodies differed significantly between healthy and affected patients. Decentralization of the odontoid process is not necessarily an indirect sign for its fracture. In patients with suspected injury of the odontoid process, an MDCT scan might be the method of choice to rule out a fracture.

  18. Atlanto-Axial Instability in People with Down’s Syndrome and its Impact on the Ability to Perform Sports Activities – A Review

    Directory of Open Access Journals (Sweden)

    Myśliwiec Andrzej

    2015-12-01

    Full Text Available Atlanto-axial instability (AAI is a developmental anomaly often occurring in persons with Down’s syndrome (DS. According to various reports, AAI affects from 6.8 to 27% of the population with DS. The aim of this review was to illustrate the issue of AAI with regard to the progressively changing state of scientific knowledge. The extended distance between the rear surface of the frontal arcus of the C1 cervical vertebra and the anterior surface of C2 cervical vertebra dens (anterior atlanto-odontoid distance, AAOD indicates the occurrence of AAI and is detectable through X-ray examination. Hypoplasia of the C2 dens, also detectable through X-ray examination, is another suggested risk factor for AAI. According to current data, the methodology of taking measurements is inconsistent, which leads to errors in interpretation. As research focusing on AAI was progressing, new data emerged from other studies on persons with DS, suggesting that neurological symptoms in persons with DS that indicated the occurrence of spinal cord compression were an important factor in medical imaging detection of AAI. One of the main arguments supporting this thesis is that in isolated cases spinal cord (SC damage was noted during screening examinations conducted on a large population of subjects. Moreover, cases in which the neurological symptoms indicate spinal cord compression existed long before the occurrence of the actual damage also remain of significant importance. Therefore, it is necessary to promote neurological studies on persons with DS to enable early diagnosis of spinal cord compression and, at the same time, reduce the use of medical imaging in cases of neurological symptoms.

  19. Multidetector Computed Tomography of Cervical Spine Fractures in Ankylosing Spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Kiuru, M.J.; Koskinen, S.K. [Helsinki Univ. Central Hospital, Toeoeloe Trauma Center (Finland). Dept. of Radiology

    2004-11-01

    Purpose: To analyze multidetector computed tomography (MDCT) cervical spine findings in trauma patients with advanced ankylosing spondylitis (AS). Material and Methods: Using PACS, 2282 cervical spine MDCT examinations requested by emergency room physicians were found during a period of 3 years. Of these patients, 18 (16 M, aged 41-87, mean 57 years) had advanced AS. Primary imaging included radiography in 12 and MRI in 11 patients. Results: MDCT detected one facet joint subluxation and 31 fractures in 17 patients: 14 transverse fractures, 8 spinous process fractures, 2 Jefferson's fractures, 1 type I and 2 type II odontoid process fractures, and 1 each: atlanto-occipital joint fracture and C2 laminar fracture plus isolated transverse process and facet joint fractures. Radiographs detected 48% and MRI 60% of the fractures. MRI detected all transverse and odontoid fractures, demonstrating spinal cord abnormalities in 72%. Conclusion: MDCT is superior to plain radiographs or MRI, showing significantly more injuries and yielding more information on fracture morphology. MRI is valuable, however, in evaluating the spinal cord and soft-tissue injuries. Fractures in advanced AS often show an abnormal orientation and are frequently associated with spinal cord injuries. In these patients, for any suspected cervical spine injuries, MDCT is therefore the imaging modality of choice.

  20. Odontoid fracture that is not listed in the existing classifications A new subtype of odontoid fracture: case report

    Directory of Open Access Journals (Sweden)

    Adam D.

    2016-03-01

    Full Text Available Background: There is a significant variety of odontoid fracture classifications along with corresponding treatment strategies. There are though cases which cannot be framed within the existing classifications.

  1. Management of Type II Odontoid Fractures: Experience from Latin American Spine Centers.

    Science.gov (United States)

    Falavigna, Asdrubal; Righesso, Orlando; da Silva, Pedro Guarise; Siri, Carlos Rocca; Daniel, Jefferson W; Esteves Veiga, José Carlos; de Azevedo, Gustavo Borges Laurindo; Carelli, Luis Eduardo; Yurac, Ratko; Sanchez Chavez, Felix Adolfo; Sfreddo, Ericson; Cecchini, Andre; do Reis, Marcelo Martins; Jiménez Avila, Jose Maria; Riew, K Daniel

    2017-02-01

    To analyze characteristics of type II odontoid fracture (TII-OF), including clinical and radiographic factors, that influence surgical planning in 8 Latin American centers. Retrospective chart review was performed of 88 patients with TII-OF between 2004 and 2015 from 8 Latin American centers. Parameters studied included 1) demographic data and causes of TII-OF, 2) clinical and neurologic presentation, 3) characteristics of fracture (degree of odontoid displacement, displacement of odontoid relative to C2 body, anatomy of fracture line, distance between fragments, presence of comminution, contact area between odontoid and C2 body), 4) type of treatment, and 5) clinical and radiographic outcome. Bone fusion was assessed using computed tomography. Mean patient age was 45.33 years ± 23.54; 78.4% of patients were male. Surgery was the primary treatment in 65 patients (73.8%), with an anterior approach in 64.6%. Surgery was usually preferred in patients with posterior or horizontal oblique fracture lines, local pain, and a smaller bone contact surface between the odontoid and the body of C2. A posterior approach was chosen when distance between the fractured bone fragments was >2 mm or after failed conservative or anterior odontoid screw treatment in a symptomatic patient. The treatment of choice for TII-OF in 8 Latin American trauma centers was surgery through an anterior approach using screw fixation. Posterior segmental C1-C2 fixation was indicated when distance between bone fragments was >2 mm and in symptomatic patients with nonunion. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract.

    Science.gov (United States)

    Leitner, L; Brückmann, C I; Gilg, M M; Bratschitsch, G; Sadoghi, P; Leithner, A; Radl, R

    2017-01-01

    Purpose . Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods . We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results . A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI) tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion . Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  3. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    L. Leitner

    2017-01-01

    Full Text Available Purpose. Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods. We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results. A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion. Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  4. Sudden onset odontoid fracture caused by cervical instability in hypotonic cerebral palsy.

    Science.gov (United States)

    Shiohama, Tadashi; Fujii, Katsunori; Kitazawa, Katsuhiko; Takahashi, Akiko; Maemoto, Tatsuo; Honda, Akihito

    2013-11-01

    Fractures of the upper cervical spine rarely occur but carry a high rate of mortality and neurological disabilities in children. Although odontoid fractures are commonly caused by high-impact injuries, cerebral palsy children with cervical instability have a risk of developing spinal fractures even from mild trauma. We herein present the first case of an odontoid fracture in a 4-year-old boy with cerebral palsy. He exhibited prominent cervical instability due to hypotonic cerebral palsy from infancy. He suddenly developed acute respiratory failure, which subsequently required mechanical ventilation. Neuroimaging clearly revealed a type-III odontoid fracture accompanied by anterior displacement with compression of the cervical spinal cord. Bone mineral density was prominently decreased probably due to his long-term bedridden status and poor nutritional condition. We subsequently performed posterior internal fixation surgically using an onlay bone graft, resulting in a dramatic improvement in his respiratory failure. To our knowledge, this is the first report of an odontoid fracture caused by cervical instability in hypotonic cerebral palsy. Since cervical instability and decreased bone mineral density are frequently associated with cerebral palsy, odontoid fractures should be cautiously examined in cases of sudden onset respiratory failure and aggravated weakness, especially in hypotonic cerebral palsy patients. Copyright © 2012 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  5. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    Science.gov (United States)

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  6. Subchondral cysts of the atlantoaxial joint: a risk factor for odontoid fractures in the elderly.

    Science.gov (United States)

    Julien, Terrill P; Schoenfeld, Andrew J; Barlow, Brian; Harris, Mitchel B

    2009-10-01

    Scholars have postulated that cervical degeneration can predispose the upper cervical spine to injury after minor trauma. Subchondral cysts have previously been recognized as potentiators of fracture in the hip and knee but no cases of cervical degenerative cysts contributing to fracture have been reported. This report documents a case series in which patients sustained significant injury to the upper cervical spine in the setting of subchondral cervical cysts. Case series/academic level I trauma center. Between 2004 and 2008, six patients (ages 73-91 years) with cervical pathology were admitted to the trauma service at our Level I trauma center. The most common mechanism of injury was a low velocity fall, which occurred in 5 out of 6 patients. All patients suffered an odontoid fracture. In all cases, there was radiographic evidence of cyst formation, and computed tomographic imaging demonstrated fracture communication with the subchondral cyst. Of the six cases, four were treated definitively with immobilization in a cervical orthosis and two required surgery. One patient was treated with an occipital-cervical fusion, whereas the other underwent Brooks wiring. All patients ultimately went on to heal their fractures. Degenerative changes in the cervical spine have previously been recognized to potentiate injury. This report raises the question of whether degenerative processes at the C1-C2 articulation predispose elderly patients to injury at this level. The presence of cystic degeneration at the atlantoaxial joint should be recognized as a potential risk factor for cervical injury after relatively minor trauma.

  7. Design of artificial human joints & organs

    CERN Document Server

    Pal, Subrata

    2013-01-01

    This book covers the design science and methodology of artificial joints and organs.  It presents the mechanical characterization of the hard and soft tissues as well as the viscoelastic properties of the tissue.

  8. [Anterior odontoid screw fixation using intra-operative cone-beam computed tomography and navigation].

    Science.gov (United States)

    Castro-Castro, Julián

    2014-01-01

    The purpose of this study was to asses the value of intraoperative cone-beam CT (O-arm) and stereotactic navigation for the insertion of anterior odontoid screws. this was a retrospective review of patients receiving surgical treatment for traumatic odontoid fractures during a period of 18 months. Procedures were guided with O-arm assistance in all cases. The screw position was verified with an intraoperative CT scan. Intraoperative and clinical parameters were evaluated. Odontoid fracture fusion was assessed on postoperative CT scans obtained at 3 and 6 months' follow-up Five patients were included in this series; 4 patients (80%) were male. Mean age was 63.6 years (range 35-83 years). All fractures were acute type ii odontoid fractures. The mean operative time was 116minutes (range 60-160minutes). Successful screw placement, judged by intraoperative computed tomography, was attained in all 5 patients (100%). The average preoperative and postoperative times were 8.6 (range 2-22 days) and 4.2 days (range 3-7 days) respectively. No neurological deterioration occurred after surgery. The rate of bone fusion was 80% (4/5). Although this initial study evaluated a small number of patients, anterior odontoid screw fixation utilizing the O-arm appears to be safe and accurate. This system allows immediate CT imaging in the operating room to verify screw position. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  9. [Short-term effectiveness of Swanson artificial joint replacement in treating posttraumatic metacarpophalangeal joint stiffness].

    Science.gov (United States)

    Lu, Hui; Shen, Xiangqian; Xu, Jihua; Huang, Xin; Ye, Po; Wu, Shoucheng

    2011-11-01

    To investigate the short-term effectiveness of Swanson artificial joint replacement in treating post-traumatic metacarpophalangeal joint stiffness. Between August 2007 and May 2010, 11 cases (13 fingers) of metacarpophalangeal joint stiffness with soft tissue defects underwent Swanson artificial joint replacement. There were 7 males (9 fingers) and 4 females (4 fingers), aged 43 to 65 years with an average of 49 years. The involved fingers included 4 thumbs, 4 index fingers, 3 middle fingers, and 2 ring fingers. The types of injury included open and crush injury in 8 fingers, fracture of the metacarpophalangeal joint in 3 fingers, metacarpophalangeal joint severing in 2 fingers. The time from joint stiffness to hospitalization was 12 to 48 weeks (mean, 24 weeks). The joint activity was (136.82 +/- 28.96) degrees. According to total active motion (TAM) assessment, included good in 1 finger, fair in 6 fingers, and poor in 6 fingers before operation. The activities of daily living were assessed by Sollerman score, which was 45.64 +/- 11.04. The X-ray films and CT scan showed traumatic arthritis of the metacarpophalangeal joint. The incision healed by first intention. All patients were followed up 12 to 34 months (mean, 24.1 months). At last follow-up, the joint activity was (194.64 +/- 28.86) degrees, showing significant difference when compared with preoperative value (t = 25.214, P = 0.000). According to TAM assessment, including excellent in 1 finger, good in 4 fingers, fair in 7 fingers, and poor in 1 finger. The Sollerman score was 67.45 +/- 8.20 postoperatively, showing significant difference when compared with the preoperative score (t = -10.470, P = 0.000). X-ray examination showed no prosthesis fracture, periprosthetic fracture, or joint dislocation occurred at last follow-up. Swanson artificial joint replacement can be applied to treat post-traumatic metacarpophalangeal joint stiffness, which can improve the joint activity and has satisfactory short

  10. The long-term functional outcome of type II odontoid fractures managed non-operatively.

    LENUS (Irish Health Repository)

    Butler, J S

    2010-10-01

    Odontoid fractures currently account for 9-15% of all adult cervical spine fractures, with type II fractures accounting for the majority of these injuries. Despite recent advances in internal fixation techniques, the management of type II fractures still remains controversial with advocates still supporting non-rigid immobilization as the definitive treatment of these injuries. At the NSIU, over an 11-year period between 1 July 1996 and 30 June 2006, 66 patients (n = 66) were treated by external immobilization for type II odontoid fractures. The medical records, radiographs and CT scans of all patients identified were reviewed. Clinical follow-up evaluation was performed using the Cervical Spine Outcomes Questionnaire (CSOQ). The objectives of this study were to evaluate the long-term functional outcome of patients suffering isolated type II odontoid fractures managed non-operatively and to correlate patient age and device type with clinical and functional outcome. Of the 66 patients, there were 42 males and 24 females (M:F = 1.75:1) managed non-operatively for type II odontoid fractures. The mean follow-up time was 66 months. Advancing age was highly correlated with poorer long-term functional outcomes when assessing neck pain (r = 0.19, P = 0.1219), shoulder and arm pain (r = 0.41, P = 0.0007), physical symptoms (r = 0.25, P = 0.472), functional disability (r = 0.24, P = 0.0476) and psychological distress (r = 0.41, P = 0.0007). Patients >65 years displayed a higher rate of pseudoarthrosis (21.43 vs. 1.92%) and established non-union (7.14 vs. 0%) than patients <65 years. The non-operative management of type II odontoid fractures is an effective and satisfactory method of treating type II odontoid fractures, particularly those of a stable nature. However, patients of advancing age have been demonstrated to have significantly poorer functional outcomes in the long term. This may be linked to higher rates of non-union.

  11. Atraumatic Occult Odontoid Fracture in Patients with Osteoporosis-Associated Thoracic Kyphotic Deformity: Report of a Case and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Kanji Mori

    2015-01-01

    Full Text Available Anderson type II odontoid fractures are reported to be the most common injury of the odontoid process in patients over the age of 65. However, atraumatic occult Anderson type III odontoid fractures have been rarely described and remain a diagnostic challenge. In the present report, we illustrate a 78-year-old female with osteoporosis-associated marked thoracic kyphotic deformity who developed atraumatic Anderson type III occult odontoid fracture and raise awareness of this condition. Anteroposterior and lateral standard radiographs of cervical spine failed to disclose odontoid fracture. Magnetic resonance imaging demonstrated intensity changes of the axis. Subsequent computed tomography clearly demonstrated Anderson type III odontoid fracture. Conservative treatment achieved complete bone union without neurological deteriorations. At 3-year follow-up, the patient was doing well without neurological and radiological deteriorations. Even if the patients have no traumatic event, we have to keep odontoid fractures in our mind as one of the differential diagnoses when we encounter elderly patients with neck pain, especially in patients with osteoporosis-associated marked thoracic kyphotic deformity.

  12. CT findings and surgical treatment of atlanto-axial rotatory fixation

    International Nuclear Information System (INIS)

    Shoji, Akira; Harano, Hideyuki; Okumura, Terufumi; Nakagawa, Hiroshi; Sugiyama, Tadamitsu.

    1984-01-01

    A case of atlanto-axial rotatory fixation (AARF) was presented in a 19-year-old female who developed sudden onset of neck pain and limitation of neck movement after direct carotid angiography for seizure disorder. Neurological examination was negative except for cock-robin posture and mild hypesthesia and hypalgesia in left C 2 distribution. Plain films of the cervical spine disclosed abnormal alignment of C 1 -C 2 and possible rotational dislocation. Bilateral selective vertebral angiography showed marked anterior and posterior displacement of left and right vertebral artery, respectively, at the level of C 1 . On CT metrizamide myelography, there was clockwise rotation of C 1 on C 2 with locked facet on the left but no evidence of cord compression was found. With diagnosis of AARF, manual reduction under general anesthesia and with fluoroscopic control was first attempted without success. Therefore, the patient underwent open reduction by using high speed air-drill and posterior fusion of C 1 to C 3 with acryl and wire. Postoperative course was uneventful and the patient went back to work as a computer operator in three months. The etiology of AARF was described by many authors, but in our case, congenital hypogenesis of transverse and alar ligaments plus minor trauma was most suggested. For neurological manifestations of AARF, occipital neuralgia, headache, neck pain, limitation of neck movement and cock-robin posture were reported, but the cock-robin posture was most characteristic and was an important symptom for the early diagnosis. In neuroradiological findings of AARF, plain CT and CT metrizamide myelography are very useful. Because they clearly demonstrate the degree of rotation and interlocking of atlanto-axial joints, and the presence of cord compression. (author)

  13. Complete Remodeling After Conservative Treatment of a Severely Angulated Odontoid Fracture in a Patient With Osteogenesis Imperfecta: A Case Report.

    Science.gov (United States)

    Colo, Dino; Schlösser, Tom P C; Oostenbroek, Hubert J; Castelein, René M

    2015-09-15

    Case report. This is the first case report describing successful healing and remodeling of a traumatic odontoid fracture that was dislocated and severely angulated in a patient with osteogenesis imperfecta who was treated conservatively. Osteogenesis imperfecta (OI) is a rare genetic disorder resulting in a low bone mass and bone fragility, predisposing these patients to fractures that often occur at a young age. Although any bone in the body may be involved, odontoid fractures are uncommon in this population. Because of a very high fusion rate, conservative management is accepted as a safe and efficient treatment of fractures of the odontoid in children. Several authors, however, recommend surgical treatment of patients who have failure of conservative treatment and have severe angulation or displacement of the odontoid. A 5-year-old female, diagnosed with OI type I, presented with neck pain without any neurological deficits after falling out of a rocking chair backward, with her head landing first on the ground. Computed tomography confirmed a type III odontoid fracture without dislocation and she was initially treated with a rigid cervical orthosis. At 1 and 2 months of follow-up, progressive severe angulation of the odontoid was observed but conservative treatment was maintained as the space available for the spinal cord was sufficient and also considering the patient's history of OI. Eight months postinjury, she had no clinical symptoms and there was osseous healing of the fracture with remodeling of the odontoid to normal morphology. Even in patients with OI, severely angulated odontoid fractures might have the capacity for osseous healing and complete remodeling under conservative treatment. 5.

  14. Diagnóstico clínico e radiográfico de luxação traumática da articulação atlanto-occipital em dois cães Clinical and radiographic diagnosis of traumatic dislocation of the atlanto-occipital joint in two dogs

    Directory of Open Access Journals (Sweden)

    B.M. Araújo

    2013-02-01

    Full Text Available A luxação da articulação atlanto-occipital é considerada uma afecção incomum no homem e nos animais. Radiografias laterais são recomendadas para o diagnóstico. No entanto, estão sujeitas a erros relacionados ao ângulo de radiação, ao alvo da imagem, à distância e à sobreposição óssea. Objetivou-se neste relato descrever os achados clínicos e radiográficos de dois cães com luxação traumática da articulação atlanto-occipital que apresentavam tetraparesia, dor cervical cranial, incapacidade de elevar a cabeça e déficits de nervos cranianos. No primeiro animal, observaram-se deslocamento craniodorsal do processo articular do atlas em relação a um dos côndilos do occipital, ausência de sobreposição dos forames vertebrais laterais e sobreposição do côndilo do occipital ao processo articular do atlas, no lado direito, caracterizando uma luxação unilateral. No segundo animal, observou-se deslocamento craniodorsal dos processos articulares do atlas em relação aos côndilos do occipital, com sobreposição dos forames vertebrais laterais e ausência de visibilização dos côndilos do occipital em virtude da projeção cranial dos processos articulares do atlas em direção ao crânio, caracterizando luxação bilateral. Conclui-se que o exame radiográfico simples, nas projeções laterolateral e ventrodorsal, apesar da dificuldade de ser interpretado, é eficiente para confirmar o diagnóstico da luxação atlanto-occipital traumática, tanto a simétrica quanto a assimétrica.Atlanto-occipital luxation is considered rare in both humans and animals. Lateral radiographs are recommended for diagnosis, however, errors may occur related to the angle of radiation, image target, distance and overlapping of bone. Our objective is to report the clinical and radiographic findings in two dogs with traumatic atlanto-occipital luxation, which had tetraparesis, cranial neck pain, and inability to raise the head and cranial

  15. Type II odontoid fractures in the elderly: an evidence-based narrative review of management.

    Science.gov (United States)

    Pal, D; Sell, P; Grevitt, M

    2011-02-01

    Considerable controversy exists regarding the optimal management of elderly patients with type II odontoid fractures. There is uncertainty regarding the consequences of non-union. The best treatment remains unclear because of the morbidity associated with prolonged cervical immobilisation versus the risks of surgical intervention. The objective of the study was to evaluate the published literature and determine the current evidence for the management of type II odontoid fractures in elderly. A search of the English language literature from January 1970 to date was performed using Medline and the following keywords: odontoid, fractures, cervical spine and elderly. The search was supplemented by cross-referencing between articles. Case reports and review articles were excluded although some were referred to in the discussion. Studies in patients aged 65 years with a minimum follow-up of 12 months were selected. One-hundred twenty-six articles were reviewed. No class I study was identified. There were two class II studies and the remaining were class III. Significant variability was found in the literature regarding mortality and morbidity rates in patients treated with and without halo vest immobilisation. In recent years several authors have claimed satisfactory results with anterior odontoid screw fixation while others have argued that this may lead to increased complications in this age group. Lately, the posterior cervical (Goel-Harms) construct has also gained popularity amongst surgeons. There is insufficient evidence to establish a standard or guideline for odontoid fracture management in elderly. While most authors agree that cervical immobilisation yields satisfactory results for type I and III fractures in the elderly, the optimal management for type II fractures remain unsolved. A prospective randomised controlled trial is recommended.

  16. Chronic Neck Pain Associated with an Old Odontoid Fracture: A Rare Presentation

    Directory of Open Access Journals (Sweden)

    Mauricio Avila-Guerra

    2013-01-01

    Full Text Available Cervical spine injuries represent a minority of injury cases in motor vehicles accidents but are a real threat to a patient’s life. In the wide range of cervical spine injuries, odontoid (dens fractures represent the most common findings. These fractures are more usually found in the elderly population due to the changes associated with age. Neurological deficit is not frequently found in these injuries. The following is a case presentation of a chronic odontoid fracture with neurological deficit in a young man that was discovered 23 years after he sustained a motor vehicle accident.

  17. Atlanto-axial approach for cervical myelography in a Thoroughbred horse with complete fusion of the atlanto-occipital bones

    Science.gov (United States)

    Aleman, Monica; Dimock, Abigail N.; Wisner, Erik R.; Prutton, Jamie W.; Madigan, John E.

    2014-01-01

    A 2-year-old Thoroughbred gelding with clinical signs localized to the first 6 spinal cord segments (C1 to C6) had complete fusion of the atlanto-occipital bones which precluded performing a routine myelogram. An ultrasound-assisted myelogram at the intervertebral space between the atlas and axis was successfully done and identified a marked extradural compressive myelopathy at the level of the atlas and axis, and axis and third cervical vertebrae. PMID:25392550

  18. Posterior atlantoaxial dislocation without odontoid fracture

    International Nuclear Information System (INIS)

    Chaudhary, Reema; Raut, Abhijit; Chaudhary, Kshitij; Metkar, Umesh; Rathod, Ashok; Sanghvi, Darshana

    2008-01-01

    We report a case of posterior atlantoaxial dislocation without a fracture of the odontoid in a 35-year-old woman. There have been nine reported cases of similar injury in the English literature. The integrity of the transverse ligament following posterior atlantoaxial dislocations has not been well documented in these reports. In the present case, MRI revealed an intact transverse ligament, which probably contributed to the stability of the C1-C2 complex following closed reduction. (orig.)

  19. [Clinical application of artificial condylar process for reconstructing temporomandibular joint].

    Science.gov (United States)

    Huang, Xiangdao; Shao, Zhanying; Wang, Fasheng; Duan, Yi

    2012-01-01

    To assess the feasibility and clinical outcomes of artificial condylar process in reconstruction of the temporomandibular joint. Between January 2005 and January 2010, the reconstructions of the temporomandibular joints with artificial condylar process were performed in 10 cases (11 sides, including 7 left sides and 4 right sides). There were 7 males and 3 females with an average age of 50 years (range, 40-68 years). Mandibular condyle defects were caused by mandible tumor in 7 patients with a mean disease duration of 15 months (range, 9-24 months) and by bilateral condylar fractures in 3 patients with the disease duration of 2, 3, and 2 days respectively. According to Neff classification, there were type M and A in 1 case, type M and B in 1 case, and type M in one side and subcondylar fracture in the other side in 1 case. Incisions in all patients healed by first intention, and no complication occurred. All cases were followed up 1 to 4 years, showed facial symmetry and good occluding relation, and the mouth opening was 22-38 mm (mean, 30 mm). No temporomandibular joint clicking or pain and no recurrence of tumor were observed. Most of the artificial condylar process were in good position except 1 deviated from the correct angle slightly. All the patients could have diet normally. The results of temporomandibular joint reconstruction after tumor resection with artificial condylar process are good, but the clinical outcome for intracapsular condylar fracture is expected to be further verified.

  20. Traumatic posterior atlantoaxial dislocation without fracture of the odontoid process: A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Yong Kyun; Park, Jin Gyoon; Jung, Hyun Nyeong [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Kim, Ju Won [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Lee, Seung Jin [Dept. of Radiology, Chonnam National University Bitgoeul Hospital, Gwangju (Korea, Republic of)

    2017-03-15

    Traumatic posterior atlantoaxial dislocation without odontoid fracture is very rare. Patient prognosis depends on the neurologic symptoms or the extent of damage to the structures. In this case, a 78-year-old-male suffered a posterior atlantoaxial dislocation without odontoid fracture after a traffic accident. We report this case because an exact diagnosis and proper treatment can reduce the neurologic complications in patients with posterior atlantoaxial dislocation.

  1. Surgical treatment of upper cervical spine injuries (c1-c2): experience in 26 patients

    International Nuclear Information System (INIS)

    Pasha, I.F.; Qureshi, M.A.; Khalique, A.B.; Afzal, W.; Qureshi, M.A.

    2013-01-01

    Objective: To describe the spectrum of operations in unstable upper cervical spinal injuries in (atlanto-axial) region at our unit. Study Design: A cross-sectional study. Place And Duration: Spine Unit, Department of Orthopedics, Combined Military Hospital (CMH), Rawalpindi from Jan 2001 to Dec 2008. Patients and Methods: Frequency of different kind of operations in 26 patients operated for upper cervical spinal injuries was reviewed. A performa was made for each patient and records were kept in a custom built Microsoft access database. Results: Average age of patients studied was 27 years with male pre dominance. Total 12(46%) patients had Atlanto-axial instability, 8(31%) had Hangman's fracture and 6(23%) patients had odontoid peg fracture. While 11(42%) patients had no neurological deficit according to American spinal injury association impairment scale (AIS-E) and 15(58%) had partial neurological deficit. The patients were divided into three groups. Group A had odontoid peg fracture, Group B had atlanto-axial instability and Group C had Hangman's fracture. The spine was approached posteriorly in 19(73(Yo) cases and anteriorly in 7(27%). Pedicle screw fixation was done in 6(23%) patients, odontoid peg screw fixation in 6(23%), Gallie's fusion in 5(19%), occipito-cervical fusion in 4(15%), posterior transarticular fixation in 3(12%), anterior transarticular fixation and decompression in others, 9(60%) patients improved neurologically postoperatively and there was no deterioration of neurological status. Nonunion in two (8%) cases and implant failure in one (4%) were complications. Conclusion: Upper cervical injuries (C1-C2) are rare and their management is complex, necessitating lot of experience for their management. Early diagnosis and appropriate treatment is essential for good outcome. Each injury has to be managed at its own merit and a single operation may not be appropriate in all situations. General guidelines can be drawn from our study for the

  2. Obstructive hydrocephalus secondary to odontoid pannus: case report and review of literature.

    Science.gov (United States)

    Soon, Wai Cheong; Thanabalasundaram, Gopiga; Thant, Kyaw Zayar; Ogbonnaya, Ebere Sunny; Harrisson, Stuart Edward

    2018-04-01

    Odontoid pannus or periodontoid pseudotumour is associated with a variety of rheumatological conditions. We report a case of an 80-year old man who presented with acute hydrocephalus following an emergency operation to amputate his infected left big toe. Imaging revealed a large tissue mass causing severe compression at the cervico-medullary junction and obstruction of CSF flow. The acute hydrocephalus was presumed to be related to neck manoeuvring during general anaesthesia. Following an initial emergency CSF diversion through external ventricular drainage catheter insertion, the patient subsequently underwent ventriculo-peritoneal insertion and posterior spinal decompression and fixation. To our knowledge, there have been no reported cases of tophaceous gout of the odontoid pannus causing acute hydrocephalus.

  3. Radiological evolution of peri-odontoid pannus in a patient with Chiari I malformation: a case-based review.

    Science.gov (United States)

    Sanders, Felipe Hada; Wang, Joy M H; Oskouian, Rod J; Tubbs, R Shane; Oakes, W Jerry

    2017-08-01

    The Chiari I malformation (CIM) is commonly encountered by neurosurgeons and can have different etiologies and clinical presentations. We report a CIM patient who presented with symptoms of ventral brain stem compression and was found to have a large peri-odontoid pannus. Posterior fossa decompression was performed with a planned second-stage odontoidectomy. However, at the 6-month follow-up, postoperative images demonstrated a mostly resolved pannus and improvement of the brain stem compression symptoms, and the patient progressed uneventfully without the need for odontoidectomy. This case illustrates the resolution of a significant and symptomatic peri-odontoid pannus in a patient with CIM without craniocervical fusion or odontoidectomy. Such a case indicates that not all peri-odontoid pannus formations in CIM patients are due to hypermobility at the craniocervical junction.

  4. A patient with an odontoid fracture and atrophy of the tongue: a case report and systematic review of the literature

    NARCIS (Netherlands)

    Kuitwaard, Krista; Vandertop, William P.

    2005-01-01

    BACKGROUND: Traumatic hypoglossal nerve palsy is a rare entity and has rarely been described in association with an odontoid fracture. CASE DESCRIPTION: We present a patient with a posttraumatic odontoid fracture who developed selective weakness of his arms and a unilateral hypoglossal nerve palsy.

  5. CT findings and surgical treatment of atlanto-axial rotatory fixation. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Shoji, Akira; Harano, Hideyuki; Okumura, Terufumi [Fukuroi Municipal Hospital, Shizuoka (Japan); Nakagawa, Hiroshi; Sugiyama, Tadamitsu

    1984-07-01

    A case of atlanto-axial rotatory fixation (AARF) was presented in a 19-year-old female who developed sudden onset of neck pain and limitation of neck movement after direct carotid angiography for seizure disorder. Neurological examination was negative except for cock-robin posture and mild hypesthesia and hypalgesia in left C/sub 2/ distribution. Plain films of the cervical spine disclosed abnormal alignment of C/sub 1/-C/sub 2/ and possible rotational dislocation. Bilateral selective vertebral angiography showed marked anterior and posterior displacement of left and right vertebral artery, respectively, at the level of C/sub 1/. On CT metrizamide myelography, there was clockwise rotation of C/sub 1/ on C/sub 2/ with locked facet on the left but no evidence of cord compression was found. With diagnosis of AARF, manual reduction under general anesthesia and with fluoroscopic control was first attempted without success. Therefore, the patient underwent open reduction by using high speed air-drill and posterior fusion of C/sub 1/ to C/sub 3/ with acryl and wire. Postoperative course was uneventful and the patient went back to work as a computer operator in three months. The etiology of AARF was described by many authors, but in our case, congenital hypogenesis of transverse and alar ligaments plus minor trauma was most suggested. For neurological manifestations of AARF, occipital neuralgia, headache, neck pain, limitation of neck movement and cock-robin posture were reported, but the cock-robin posture was most characteristic and was an important symptom for the early diagnosis. In neuroradiological findings of AARF, plain CT and CT metrizamide myelography are very useful. Because they clearly demonstrate the degree of rotation and interlocking of atlanto-axial joints, and the presence of cord compression.

  6. Atlantoaxial Subluxation after Pyogenic Spondylitis around the Odontoid Process

    Directory of Open Access Journals (Sweden)

    Atsushi Hasegawa

    2015-01-01

    Full Text Available Study Design. A case report and review of the literature. Objective. The aim of this study was to describe the conservative management of pyogenic spondylitis around the odontoid process. Summary of Background Data. Atlantoaxial subluxation after pyogenic spondylitis is rare. The therapeutic approach to infection of the upper cervical spine is controversial. Methods. Medical chart and radiological images of a 76-year-old male patient were retrospectively reviewed. Radiography revealed atlantoaxial subluxation, and an abscess was seen around the odontoid process on magnetic resonance images. Intravenous antibiotics and a halo vest were used to treat the patient. We then observed the patient’s conservative treatment course. Results. C-reactive protein levels returned to normal 4 weeks after administration of the intravenous antibiotics. The patient’s muscle weakness also completely recovered 8 weeks after administration of the intravenous antibiotics. Because the patient was able to walk without any support, surgical treatment was not necessary. Conclusions. Pyogenic spondylitis of the upper cervical spine is a rare manifestation. Surgical or conservative treatment must be selected carefully based on the patient’s symptoms. If early diagnosis and treatment can be provided to the patients, conservative treatment can be achieved.

  7. Atlantoaxial instability: An exceptional complication of ankylosing spondylitis

    Directory of Open Access Journals (Sweden)

    Zeineb Alaya

    2018-04-01

    Full Text Available Background: Atlantoaxial instability (AAI and more rarely odontoid pannus formation, similar to the one observed in Rheumatoid Arthritis, are seldom reported in ankylosing spondylitis (AS. We report a new case of a patient with AS with a pannus in the atlanto-axial region and cervical C1-C2 instability. Case presentation: The patient, now aged 41, was diagnosed with AS in 2010. She was put on different non steroidal anti inflammatory treatments with persistent spinal pain. She was referred to our department in 2015 with severe cervical pain and stiffness since 3 months. On examination, the patient had severely limited cervical spine movements. Lumbar spine movements were moderately affected. There was no neurological deficit. Her Bath Ankylosing Spondylitis Disease Activity Index (BASDAI was 4.9/10 and Bath Ankylosing Spondylitis Functional Index (BASFI was 5/10. Plain Radiographs of the pelvis showed bilateral grade 4 sacroilitis and bilateral coxitis. Dorsal and lumbar spine plain radiographs showed squaring of vertebral bodies. Cervical spine radiographs showed an increased atlanto-axial distance. Spinal MRI confirmed the atlantoaxial subluxation with an anterior distance of 8 mm, with marked intraspinal pannus formation and synovitis around the odontoid peg. Synovial thickening exerted an anterior mark on the bulbo-medullary junction with no evidence of oedema signs. Posterior zygapophysial ankylosis involving all cervical levels was also observed. The patient had a cervical collar with anti-tumor necrosis factor-α (cerolizumab-pegol prescription with favorable outcome. Conclusion: Odontoid pannus formation is rare in AS. Clinical and radiological follow-up are important to assess the impact on the cervical spine. Keywords: Ankylosing spondylitis, Atlantoaxial instability, MRI, Cerolizumab-pegol

  8. Biofluid lubrication for artificial joints

    Science.gov (United States)

    Pendleton, Alice Mae

    This research investigated biofluid lubrication related to artificial joints using tribological and rheological approaches. Biofluids studied here represent two categories of fluids, base fluids and nanostructured biofluids. Base fluids were studied through comparison of synthetic fluids (simulated body fluid and hyaluronic acid) as well as natural biofluids (from dogs, horses, and humans) in terms of viscosity and fluid shear stress. The nano-structured biofluids were formed using molecules having well-defined shapes. Understanding nano-structured biofluids leads to new ways of design and synthesis of biofluids that are beneficial for artificial joint performance. Experimental approaches were utilized in the present research. This includes basic analysis of biofluids' property, such as viscosity, fluid shear stress, and shear rate using rheological experiments. Tribological investigation and surface characterization were conducted in order to understand effects of molecular and nanostructures on fluid lubrication. Workpiece surface structure and wear mechanisms were investigated using a scanning electron microscope and a transmission electron microscope. The surface topography was examined using a profilometer. The results demonstrated that with the adding of solid additives, such as crown ether or fullerene acted as rough as the other solids in the 3-body wear systems. In addition, the fullerene supplied low friction and low wear, which designates the lubrication purpose of this particular particle system. This dissertation is constructed of six chapters. The first chapter is an introduction to body fluids, as mentioned earlier. After Chapter II, it examines the motivation and approach of the present research, Chapter III discusses the experimental approaches, including materials, experimental setup, and conditions. In Chapter IV, lubrication properties of various fluids are discussed. The tribological properties and performance nanostructured biofluids are

  9. AtlantOS - Optimizing and Enhancing the Integrated Atlantic Ocean Observing System

    Science.gov (United States)

    Reitz, Anja; Visbeck, Martin; AtlantOS Consortium, the

    2016-04-01

    Atlantic Ocean observation is currently undertaken through loosely-coordinated, in-situ observing networks, satellite observations and data management arrangements of heterogeneous international, national and regional design to support science and a wide range of information products. Thus there is tremendous opportunity to develop the systems towards a fully integrated Atlantic Ocean Observing System consistent with the recently developed 'Framework of Ocean Observing'. The vision of AtlantOS is to improve and innovate Atlantic observing by using the Framework of Ocean Observing to obtain an international, more sustainable, more efficient, more integrated, and fit-for-purpose system. Hence, the AtlantOS initiative will have a long-lasting and sustainable contribution to the societal, economic and scientific benefit arising from this integrated approach. This will be delivered by improving the value for money, extent, completeness, quality and ease of access to Atlantic Ocean data required by industries, product supplying agencies, scientist and citizens. The overarching target of the AtlantOS initiative is to deliver an advanced framework for the development of an integrated Atlantic Ocean Observing System that goes beyond the state-of -the-art, and leaves a legacy of sustainability after the life of the project. The legacy will derive from the following aims: i) to improve international collaboration in the design, implementation and benefit sharing of ocean observing, ii) to promote engagement and innovation in all aspects of ocean observing, iii) to facilitate free and open access to ocean data and information, iv) to enable and disseminate methods of achieving quality and authority of ocean information, v) to strengthen the Global Ocean Observing System (GOOS) and to sustain observing systems that are critical for the Copernicus Marine Environment Monitoring Service and its applications and vi) to contribute to the aims of the Galway Statement on Atlantic

  10. Fraturas de odontoide tipo III com necessidade de tratamento cirúrgico: estudo de série de casos e revisão de literatura Fracturas de odontoides tipo III con necesidad de tratamiento quirúrgico: estudio de série de casos y revisión de la literatura Type III odontoid fractures requiring surgical treatment: a case series study and literature review

    Directory of Open Access Journals (Sweden)

    Alan Robert Wieczorek

    2011-01-01

    Full Text Available OBJETIVO: Analisar uma série de pacientes com fraturas de odontoide do tipo III, instáveis, tratados cirurgicamente. MÉTODOS: Análise retrospectiva de uma série de 5 casos consecutivos de pacientes com fratura de odontoide do tipo III, submetidos a tratamento cirúrgico. RESULTADOS: Três pacientes foram tratados inicialmente com halo-veste e, nos casos de falha, foram submetidos a osteossíntese cirúrgica. Dois pacientes, um com grande instabilidade radiológica em flexão e compressão medular e outro com comprometimento neurológico, foram submetidos a tratamento cirúrgico primário. A técnica cirúrgica foi individualizada para cada caso. Não ocorreram complicações graves; quatro pacientes evoluíram assintomáticos e somente um paciente desenvolveu dor cervical não incapacitante. A tomografia computadorizada (TC mostrou consolidação da fratura em 2 casos, os demais não realizaram TC de controle. O seguimento médio foi de 1,9 anos. CONCLUSÕES: Fraturas de odontoide do tipo III nem sempre são lesões benignas, sendo importante individualizar seu tratamento sempre que alguma característica incomum for identificada. Existem critérios de instabilidade e indicação de tratamento cirúrgico para pacientes com este tipo de lesão.OBJETIVO: Analizar los casos de una serie de pacientes con fracturas de odontoides del tipo III inestables, tratadas quirúrgicamente. MÉTODOS: Análisis retrospectiva de una serie de 5 casos consecutivos de pacientes con fractura de odontoides del tipo III, sometidos a tratamiento quirúrgico. RESULTADOS: Tres pacientes fueran tratados al comienzo con halo veste y, en la falla de este, se sometieron a osteosíntesis quirúrgica. Dos pacientes, uno con inestabilidad radiológica importante en flexión y compresión medular y otro con déficit neurológico se sometieron a tratamiento quirúrgico primario. La técnica quirúrgica se individualizó para cada uno de los casos. No ocurrieron complicaciones

  11. MRI of the tectorial and posterior atlanto-occipital membranes in the late stage of whiplash injury

    Energy Technology Data Exchange (ETDEWEB)

    Krakenes, J.; Moen, G.; Nordli, H.; Rorvik, J. [Department of Radiology, University of Bergen and Haukeland University Hospital, 5021, Bergen (Norway); Kaale, B.R. [Firda Medical Centre, 6823, Sandane (Norway); Gilhus, N.E. [Department of Neurology, University of Bergen and Haukeland University Hospital, 5021, Bergen (Norway)

    2003-09-01

    Our aim was to characterise and classify permanent structural changes in the tectorial and posterior atlanto-occipital membranes several years after a whiplash injury, and to evaluate the reliability of our classification. We obtained sagittal proton density-weighted images of the craniovertebral junction of 92 whiplash-injured and 30 uninjured individuals. Structural abnormalities in the two membranes were classified as grades 1-3 independently by three radiologists blinded for clinical information. Grading criteria were based on reduced tectorial membrane thickness, and elongation or rupture of the posterior atlanto-occipital membrane/dura mater complex. The same images were reassessed 4 months later. Image quality was graded good in 104 cases, slightly reduced in 13 and unsatisfactory in five. Of 117 tectorial membranes 31 (26.5%) showed grade 2 or 3 lesions, in the uninjured group none were grade 3 and only three were grade 2. Pair-wise interobserver agreement (weighted kappa) was moderate (0.47-0.50), while the intraobserver agreement was moderate to good (0.51-0.70). Of 117 posterior atlanto-occipital membranes 20 (17.1%) had grade 2 or 3 lesions; there was no grade 3 and only one grade 2 lesion in the uninjured group. Inter- and intraobserver agreement was good (0.61-0.74 and 0.65-0.86, respectively). Reduced image quality was the main reason for disagreement, but partial thinning and lateral tapering, as normal tectorial membrane variations, created difficulties in some cases. This study strongly indicates that whiplash trauma can damage the tectorial and posterior atlanto-occipital membranes; this can be shown on high-resolution MRI. Better knowledge of normal anatomical variations and improved image quality should increase the reliability of lesion classification. (orig.)

  12. MRI of the tectorial and posterior atlanto-occipital membranes in the late stage of whiplash injury

    International Nuclear Information System (INIS)

    Krakenes, J.; Moen, G.; Nordli, H.; Rorvik, J.; Kaale, B.R.; Gilhus, N.E.

    2003-01-01

    Our aim was to characterise and classify permanent structural changes in the tectorial and posterior atlanto-occipital membranes several years after a whiplash injury, and to evaluate the reliability of our classification. We obtained sagittal proton density-weighted images of the craniovertebral junction of 92 whiplash-injured and 30 uninjured individuals. Structural abnormalities in the two membranes were classified as grades 1-3 independently by three radiologists blinded for clinical information. Grading criteria were based on reduced tectorial membrane thickness, and elongation or rupture of the posterior atlanto-occipital membrane/dura mater complex. The same images were reassessed 4 months later. Image quality was graded good in 104 cases, slightly reduced in 13 and unsatisfactory in five. Of 117 tectorial membranes 31 (26.5%) showed grade 2 or 3 lesions, in the uninjured group none were grade 3 and only three were grade 2. Pair-wise interobserver agreement (weighted kappa) was moderate (0.47-0.50), while the intraobserver agreement was moderate to good (0.51-0.70). Of 117 posterior atlanto-occipital membranes 20 (17.1%) had grade 2 or 3 lesions; there was no grade 3 and only one grade 2 lesion in the uninjured group. Inter- and intraobserver agreement was good (0.61-0.74 and 0.65-0.86, respectively). Reduced image quality was the main reason for disagreement, but partial thinning and lateral tapering, as normal tectorial membrane variations, created difficulties in some cases. This study strongly indicates that whiplash trauma can damage the tectorial and posterior atlanto-occipital membranes; this can be shown on high-resolution MRI. Better knowledge of normal anatomical variations and improved image quality should increase the reliability of lesion classification. (orig.)

  13. An Odontoid Fracture Causing Apnea, Cardiac Instability, and Quadriplegia

    Directory of Open Access Journals (Sweden)

    Christian A. Bowers

    2012-01-01

    Full Text Available Odontoid fractures are typically associated with low rates of acute neurologic deficit and morbidity/mortality in nonelderly patients. In the patient in this case, traumatic injury triggered by a syncopal event led to a combined C1-C2 fracture and a fatal spinal cord injury with apnea, quadriplegia, and cardiovascular instability. We briefly review the anatomical basis for the pathophysiology of cardiac dysfunction following high-cervical spine injury and present an example of a worst-case scenario.

  14. Case report 344: Tuberculous spondyilitis resulting in atlanto-axial dislocation

    International Nuclear Information System (INIS)

    Dowd, C.F.; Sartoris, D.J.; Resnick, D.; Haghighi, P.

    1986-01-01

    In summary, this case exhibits many of the typical features of atlanto-axial tuberculous spondylitis, including its presenting symptomatology and radiological manifestations. No other sites of tuberculous involvement were discovered on subsequent work-up in this patient. He was treated with traction and transoral debridement of soft tissues and bone, followed by anti-tuberculous chemotherapy for eight weeks and a posterior spinal fusion. The patient subsequently recovered full motor and sensory function and is currently undergoing rehabilitation therapy several months following surgery. (orig.)

  15. Unilateral fusion of the odontoid process with the atlas in Klippel-Feil syndrome: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, So Young; Ryu, Kyung Nam; Park, Ji Seon; Suk, Kyung Soo; Han, Mi Young [Kyunghee Medical Center, Seoul (Korea, Republic of)

    2006-07-15

    Klippel-Feil syndrome (KFS) displays congenital fusion of the cervical vertebrae; it is a relatively common condition and has many associated malformations such as Sprengel's deformity, scoliosis, rib anomalies, congenital defects of the brain or spinal cord, renal anomalies, congenital heart disease, deafness, cleft palate, cranial and facial asymmetry, and enteric cysts. There are various types of cervical fusion observed in KFS. However, fusion of the odontoid process with the atlas is a very rare finding. We report here on a 4-year-old boy with unilateral fusion of a separated odontoid process with the lateral mass of the atlas, and this was associated with a spontaneously closed ventricular septal defect, a small patent ductus arteriosus and a horseshoe kidney.

  16. A Symptomatic Displaced Os Odontoideum: A Case Report

    Directory of Open Access Journals (Sweden)

    Farshad Nikouei

    2016-05-01

    Full Text Available Introduction Os odontoideum (OO is a form of odontoid anomaly presented by a separate ossicle with a smooth, sclerotic border not fused with C2 body. The current paper reports a boy with irreducible displaced os odontoideum with severe neurologic deficit after a minor trauma. Case Presentation A 16-year-old boy admitted in the center due to neck pain and torticollis with neurologic deficit. He had a history of multiple minor traumas. Advanced imaging assessment demonstrated displaced os odontoideum with minimal space available for cord (SAC and myelomalacia. After unsuccessful closed reduction a 2-stage operation was planned: first, the anterior transoral release and odontoid resection with subsequent halo-traction and second, the posterior atlanto-axial instrumented fusion with bilateral C1 hook and C2 pedicular screws. Conclusions Congenital anomalies of the odontoid are associated with C1-C2 instability that can be subluxated or dislocated with minor trauma and cause permanent neurologic deficit or even death. When acute cervical spine trauma is imaged, os odontoideum should be distinguished from an acute dens fracture with a multimodality imaging approach including computed tomography (CT, magnetic resonance imaging (MRI and radiography. Here is the report of a rare case with irreducible displaced os odontiodeum treated him with anterior release, odontoid resection and posterior C1-C2 instrumented fusion.

  17. Relationship between pharyngitis and peri-odontoid pannus: A new etiology for some Chiari I malformations?

    Science.gov (United States)

    Tubbs, R Shane; Griessenauer, Christoph J; Hendrix, Philipp; Oakes, Peter; Loukas, Marios; Chern, Joshua J; Rozzelle, Curtis J; Oakes, W Jerry

    2015-07-01

    The pathophysiology underlying Chiari I malformations (CIMs) provides room for debate with several theories attempting to address this issue. We retrospectively reviewed many of our past patients with pediatric CIMs (specifically, those with peri-odontoid pannus), and present a hypothesis for the development of the malformation in some of said patients. Our experience with the pediatric CIM has shown that almost 1 in 20 patients who present with symptoms is found to have a peri-odontoid pannus. These masses ranged in size from 4 to 11 mm in diameter. Forty percent had a history of clinically significant pharyngitis or pharyngeal abscess. Pannus formation around the dens (odontoid) resulted in ventral compression of the craniocervical junction in each of these patients. Highlighting the hypermobility that causes such lesions, following fusion, the pannus and symptoms in several patients were diminished. Impairment of normal cerebrospinal fluid circulation out of the fourth ventricle and across the craniocervical junction appears to be a plausible endpoint in this discussion and a suitable explanation for some patients with CIM. Still, the mechanisms by which cerebrospinal fluid circulation is compromised may be variable and are not well understood. This is the first study dedicated to the evaluation of pannus formation in the CIM population. We hypothesize that pharyngeal inflammatory conditions contribute to the formation and progression of hindbrain herniation in a small subset of patients with CIMs. © 2015 Wiley Periodicals, Inc.

  18. Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures.

    Science.gov (United States)

    Park, Jin Hoon; Kang, Dong-Ho; Lee, Moon Kyu; Yoo, Byoungwoo; Jung, Sang Ku; Hwang, Soo-Hyun; Kim, Jeoung Hee; Oh, Sunkyu; Lee, Eun Jung; Jeon, Sang Ryong; Roh, Sung Woo; Rhim, Seung Chul

    2016-05-01

    A retrospective cohort study. The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. 3.

  19. Design and preliminary biomechanical analysis of artificial cervical joint complex.

    Science.gov (United States)

    Jian, Yu; Lan-Tao, Liu; Zhao, Jian-ning; Jian-ning, Zhao

    2013-06-01

    To design an artificial cervical joint complex (ACJC) prosthesis for non-fusion reconstruction after cervical subtotal corpectomy, and to evaluate the biomechanical stability, preservation of segment movements and influence on adjacent inter-vertebral movements of this prosthesis. The prosthesis was composed of three parts: the upper/lower joint head and the middle artificial vertebrae made of Cobalt-Chromium-Molybdenum (Co-Cr-Mo) alloy and polyethylene with a ball-and-socket joint design resembling the multi-axial movement in normal inter-vertebral spaces. Biomechanical tests of intact spine (control), Orion locking plate system and ACJC prosthesis were performed on formalin-fixed cervical spine specimens from 21 healthy cadavers to compare stability, range of motion (ROM) of the surgical segment and ROM of adjacent inter-vertebral spaces. As for stability of the whole lower cervical spine, there was no significant difference of flexion, extension, lateral bending and torsion between intact spine group and ACJC prosthesis group. As for segment movements, difference in flexion, lateral bending or torsion between ACJC prosthesis group and control group was not statistically significant, while ACJC prosthesis group showed an increase in extension (P inter-vertebral ROM of the ACJC prosthesis group was not statistically significant compared to that of the control group. After cervical subtotal corpectomy, reconstruction with ACJC prosthesis not only obtained instant stability, but also reserved segment motions effectively, without abnormal gain of mobility at adjacent inter-vertebral spaces.

  20. [Meniscoids of the intervertebral joints].

    Science.gov (United States)

    Kos, J; Hert, J; Sevcík, P

    2002-01-01

    A large amount of material was used to study the distribution, location and shape of meniscoids in intervertebral joints of the human spine, from the atlanto-occipital joint to the sacrum, in order to find out how many of intervertebral joints had mobile meniscoids. These might be regarded as possible causes of spinal blockade or other vertebrogenous complaints. The materials provided by the Department of Anatomy and Department of Forensic Medicine at the Faculty of Medicine of Charles University in Pilznen included 20 cadaverous spines from humans aged 20 to 80 years. Access to each joint was provided by dissection of the articular capsule from the lower articular processes of the vertebra situated above. In the orthograde view, all meniscoids were described in terms of shape, size, consistence and location. Their structure was ascertained by histological examination of cross sections stained with haematoxylin and eosin. Meniscoids varying in shape and size were found in all of the intervertebral joints. They were classified by their histological structure as synovial, fat and fibrous meniscoids. The first category was observed frequently, the last only rarely. A total of 29 mobile meniscoids were recorded, most of them in the lumbar spine. Most of the meniscoids present in the cervical spine were of synovial and less frequently of fat types. Meniscoids found in the thoracic spine were poorly developed synovial ones and those present in the lumbar spine were of all types and were also largest in size. The most conspicuous meniscoids were seen in the spines that showed degenerative changes in intervertebral joints. Large fat pads were found in atlanto-occipital and atlanto-axial joints. Mobile meniscoids, most of them present in the lumbar spine (6.4% of all joints.), were connected with the capsule by a thin pedicle and it was possible to move them over a half of the articular surface. Some inter-individual changes were also found; in some spines, the most

  1. A Cohort Study of the Natural History of Odontoid Pseudoarthrosis Managed Nonoperatively in Elderly Patients.

    Science.gov (United States)

    Hong, Jennifer; Zaman, Rifat; Coy, Shannon; Pastel, David; Simmons, Nathan; Ball, Perry; Mirza, Sohail; Abdu, William; Pearson, Adam; Lollis, S Scott

    2018-06-01

    Although the primary goal of treatment of type II odontoid fracture is bony union, some advocate continued nonsurgical management of minimally symptomatic older patients who have fibrous union or minimal fracture motion. The risk of this strategy is unknown. We reviewed our long-term outcomes after dens nonunion to define the natural history of Type II odontoid fractures in elderly patients managed nonoperatively. A retrospective chart review of 50 consecutive adults aged 65 or older with Type II odontoid fracture initially managed nonsurgically from 1998 to 2012 at a single tertiary care institution was conducted. Particular attention was paid to patients who had orthosis removal despite absent bony fusion. Patients were contacted prospectively by telephone and followed until death, surgical intervention, or last known contact. Fifty patients initially were managed nonsurgically; of these, 21 (42.0%) proceeded to bony fusion, 3 (6%) underwent delayed surgery for persistent instability, and 26 (52%) had orthosis removal despite the lack of solid arthrodesis on imaging. The last group had a median follow-up of 25 months (range 4-158 months), with 20 of 26 (76.9%) followed until death. Of these patients, 1 patient developed progressive quadriplegia and dysphagia 11 months after initial injury. Compared with patients with spontaneous union, patients with nonunion had shorter life expectancy, despite no significant differences between the groups with respect to age, sex, injury mechanism, radiographic variables, or follow-up duration. Orthosis removal despite fracture nonunion may be reasonable in elderly patients with Type II dens fractures. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. MRI of atlantoaxial subluxation; Correlating with plain X-ray films and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Saikawa, Yuko; Nishi, Naoko; Saitoh, Yoko; Akimura, Rumiko; Sasaki, Taisuke; Yodono, Hiraku; Takekawa, Shoichi; Harata, Seikou; Sannohe, Akio (Hirosaki Univ., Aomori (Japan). School of Medicine)

    1991-04-01

    Twenty-three patients with atlantoaxial subluxation (14 with rheumatoid arthritis, one each with rheumatoid arthritis and Arnold-Chiari malformation, os odontoideum, Klippel-Feil syndrome, trauma, and 5 with unknown causes) were evaluated with MRI. We used 0.5 T MRI unit (RESONA; Yokogawa Medical Systems, Japan) and 1.5 T MRI unit (SMT 150; Shimazu, Japan) with head or flexible coils. We compared the usefulness of MRI with those of plain X-ray films and CT regarding several points. MRI provided better image of the soft tissue mass around the odontoid process, compression of cord or subarachnoid space than plain X-ray films and CT. Atlanto-odontoid distance on MRI is nearer to that on plain X-ray films than CT. MRI is useful in analyzing the anatomic details such as transverse ligament, alar ligament, tectorial membrane and thickened synovium. Both MRI and CT provided detailed bony changes. High correlation was observed between MRI grading of cord compression and the degree of myelopathy. (author).

  3. Tratamento das fraturas do processo odontóide Treatment of odontoid fractures

    Directory of Open Access Journals (Sweden)

    Pedro Augusto Pontin

    2011-01-01

    Full Text Available OBJETIVO: Este artigo faz a avaliação retrospectiva clínica e radiológica das fraturas do odontóide de 20 pacientes atendidos no IOT-HCFMUSP, durante o período de 2004-2010. MÉTODOS: Foi realizado a estratificação destas fraturas segundo sua classificação (AO/Anderson e D'Alonzo, perfil epidemiológico, tipo de tratamento, tempo de consolidação e complicações. RESULTADOS: Observou-se maior número de casos da fratura do odontóide em pacientes do sexo masculino (4:1, com idade entre 3ª e 4ª década de vida (60%, vítimas de quedas de altura (60% e acidentes automobilísticos (25% como principais mecanismos de trauma, e 15% dos casos apresentaram-se com déficit neurológico. A fraturas do odontóide de maior prevalência foram as do tipo II (55%, seguidas pelas fraturas do tipo III (40%. Os tratamentos mais empregados nas fraturas do tipo II e III foram, respectivamente, o cirúrgico (73% e conservador (87,5%. A consolidação ocorreu em até 16 semanas para 87,5% dos casos de tratamento cirúrgico e para 54,5% dos tratados conservadoramente. Não houve casos de pseudoartrose. CONCLUSÃO: O tratamento cirúrgico das fraturas do odontóide do tipo II apresentou resultados satisfatórios em relação ao tempo consolidação e baixa incidência de complicações, bem como o tratamento conservador destinado às fraturas do tipo III.Nivel de Evidência IV, série de casos.OBJECTIVE: This article describes a clinical and radiologic retrospective analysis of odontoid fractures in20 patients accompanied byThe IOT-HCFMUSP,from 2004 to 2010. METHODS: These fractures were stratified according to their classification (AO/Anderson andD'Alonzo, epidemiologic profile, type of treatment, time to consolidation of the fracture, and complications. RESULTS: It was observed that there was a higher number of odontoid fractures in males (4:1, between the third and fourth decades of life (60%, and that the main causes of the trauma were falling from

  4. Reconstruction of chronic acromioclavicular joint disruption with artificial ligament prosthesis

    Directory of Open Access Journals (Sweden)

    Chouhan Devendra Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: Management of Rockwood type 3 acromioclavicular disruptions is a matter of debate. Should we adopt conservative or operative measures at first presentation? It is not clear but most of the evidences are in favour of conservative management. We present our expe-rience in managing these patients surgically. Methods: We present a prospective series of eight cases of chronic Rockwood type 3 acromioclavicular joint disruptions treated surgically. Anatomical reconstruction of the coracoclavicular ligament was done by artificial braided polyester ligament prosthesis. Results: All the patients were able to perform daily activities from an average of the 14th postoperative day. All patients felt an improvement in pain, with decrease in ave-rage visual analogue scale from preoperative 6.5 points (range 3-9 points to 2.0 points (range 0-5 points, Constant score from 59% to 91% and American Shoulder and Elbow Surgeons shoulder score from 65 to 93 points postoperatively. These results improved or at least remained stationary on midterm follow-up, and no deterioration was recorded at an average follow-up of 46 months. Conclusion: This midterm outcome analysis of the artificial ligament prosthesis is the first such follow-up study with prosthesis. Our results are encouraging and justify the further use and evaluation of this relatively new and easily reproducible technique. Key words: Acromioclavicular joint; Prostheses and implants; Reconstructive surgical procedures; Ligaments

  5. Unilateral atlanto-axial fractures in near side impact collisions: An under recognized entity in cervical trauma

    Directory of Open Access Journals (Sweden)

    Andrew M Lozen

    2014-01-01

    Full Text Available Objective: Nearside impact collisions presenting with lateral mass fractures of atlanto-axial vertebrae contralateral to the impact site represents a rare fracture pattern that does not correlate with previously described injury mechanism. We describe our clinical experience with such fractures and propose a novel description of biomechanical forces involved in this unique injury pattern. The findings serve to alert clinicians to potentially serious consequences of associated unrecognized and untreated vertebral artery injury. Material and Methods : In addition to describing our clinical experience with three of these fractures, a review of Crash Injury Research and Engineering Network (CIREN database was conducted to further characterize such fractures. A descriptive analysis of three recent lateral mass fractures of the atlanto-axial segment is coupled with a review of the CIREN database. A total of 4047 collisions were screened for unilateral fractures of atlas or axis. Information was screened for side of impact and data regarding impact velocity, occupant injuries and use of restraints. Results: Following screening of unilateral fractures of atlas and axis for direct side impacts, 41 fractures were identified. Cross referencing these cases for occurrence contralateral to side of impact identified four such fractures. Including our recent clinical experience, seven injuries were identified: Five C1 and two C2 fractures. Velocity ranged from 14 to 43 km/h. Two associated vertebral artery injuries were identified. Conclusions: Complexity of the atlanto-axial complex is responsible for a sequence of events that define load application in side impacts. This study demonstrates the vulnerability of vertebral artery to injury under unique translational forces and supports the use or routine screening for vascular injury. Diminished sensitivity of plain radiography in identifying these injuries suggests that computerized tomography should be used in

  6. Type III odontoid fractures: A subgroup analysis of complex, high-energy fractures treated with external immobilization

    Directory of Open Access Journals (Sweden)

    Thomas E Niemeier

    2018-01-01

    Conclusions: Complex Type III odontoid fractures are distinctly different from low-energy injuries. In the current study, 21% of patients were unsuccessfully treated nonoperatively with external immobilization and required surgery. For complex Type III fractures, we recommend initial conservative treatment, while maintaining close monitoring throughout patient recovery and fracture union.

  7. Harmonising and semantically linking key variables from in-situ observing networks of an Integrated Atlantic Ocean Observing System, AtlantOS

    Science.gov (United States)

    Darroch, Louise; Buck, Justin

    2017-04-01

    Atlantic Ocean observation is currently undertaken through loosely-coordinated, in-situ observing networks, satellite observations and data management arrangements at regional, national and international scales. The EU Horizon 2020 AtlantOS project aims to deliver an advanced framework for the development of an Integrated Atlantic Ocean Observing System that strengthens the Global Ocean Observing System (GOOS) and contributes to the aims of the Galway Statement on Atlantic Ocean Cooperation. One goal is to ensure that data from different and diverse in-situ observing networks are readily accessible and useable to a wider community, including the international ocean science community and other stakeholders in this field. To help achieve this goal, the British Oceanographic Data Centre (BODC) produced a parameter matrix to harmonise data exchange, data flow and data integration for the key variables acquired by multiple in-situ AtlantOS observing networks such as ARGO, Seafloor Mapping and OceanSITES. Our solution used semantic linking of controlled vocabularies and metadata for parameters that were "mappable" to existing EU and international standard vocabularies. An AtlantOS Essential Variables list of terms (aggregated level) based on Global Climate Observing System (GCOS) Essential Climate Variables (ECV), GOOS Essential Ocean Variables (EOV) and other key network variables was defined and published on the Natural Environment Research Council (NERC) Vocabulary Server (version 2.0) as collection A05 (http://vocab.nerc.ac.uk/collection/A05/current/). This new vocabulary was semantically linked to standardised metadata for observed properties and units that had been validated by the AtlantOS community: SeaDataNet parameters (P01), Climate and Forecast (CF) Standard Names (P07) and SeaDataNet units (P06). Observed properties were mapped to biological entities from the internationally assured AphiaID from the WOrld Register of Marine Species (WoRMS), http

  8. Surgical treatment of children with non-traumatic old atlanto-axial rotatory fixation

    Directory of Open Access Journals (Sweden)

    A. V. Gubin

    2015-01-01

    Full Text Available Atlanto-axial rotatory fixation (AORF develops on the background of acute torticollis. Widely adopted terms such as C1 subluxation or atlantooccipital rotational subluxation do not reflect the core of this pathology and carry negative weight in the diagnostics and treatment of AORF. Retrospective analysis of the diagnostics and treatment outcome of 5 children with confirmed AORF diagnosis and literature review were performed. Clinical method, radiography and functional computer tomography were used to verify the diagnosis. De-rotational halo-traction and open correction with screw fixation were applied for treatment. Head position was managed to be improved in all patients. In one case the reduction was performed using correction in suboccipital segments and in other 4 cases the correction and fixation by Harms and de-rotational halo-traction allowed to correct torticollis. The pain syndrome had been arrested completely. Disease outcome resulted in formation of C1-C2 fibrous or bone fusion regardless the method of treatment. The patients with neglected AORF represent a great challenge for diagnostics and treatment. When conservative treatment fails it is necessary to involve de-rotational halo-traction with possible application of open reduction and posterior fusion. The purpose of treatment is to eliminate torticollis and pain using creation of proper C1-C2 alignment. The motions in atlantooccipital joint do not restore due to formation of the fibrous or bone fusion.

  9. Feasibility of Modified Anterior Odontoid Screw Fixation: Analysis of a New Trajectory Using 3-Dimensional Simulation Software.

    Science.gov (United States)

    Zhang, Li-Lian; Chen, Qi; Wang, Hao-Li; Xu, Hua-Zi; Tian, Nai-Feng

    2018-05-03

    Anterior odontoid screw fixation (AOSF) has been suggested as the optimal treatment for type II and some shallow type III odontoid fractures. However, only the classical surgical trajectory is available; no newer entry points or trajectories have been reported. We evaluated the anatomic feasibility of a new trajectory for AOSF using 3-dimensional (3D) screw insertion simulation software (Mimics). Computed tomography (CT) scans of patients (65 males and 59 females) with normal cervical structures were obtained consecutively, and the axes were reconstructed in 3 dimensions by Mimics software. Then simulated operations were performed using 2 new entry points below the superior articular process using bilateral screws of different diameters (group 1: 4 mm and 4 mm; group 2: 4 mm and 3.5 mm; group 3: 3.5 mm and 3.5 mm). The success rates and the required screw lengths were recorded and analyzed. The success rates were 79.03% for group 1, 95.16% for group 2, and 98.39% for group 3. The success rates for groups 2 and 3 did not differ significantly, and both were significantly better than the rate for group 1. The success rate was much higher in males than in females in group 1, but the success rate was similar in males and females in the other 2 groups. Screw lengths did not differ significantly among the 3 groups, but an effect of sex was apparent. Our modified trajectory is anatomically feasible for fixation of anterior odontoid fractures, but further anatomic experiments and clinical research are needed. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. An activated energy approach for accelerated testing of the deformation of UHMWPE in artificial joints.

    Science.gov (United States)

    Galetz, Mathias Christian; Glatzel, Uwe

    2010-05-01

    The deformation behavior of ultrahigh molecular polyethylene (UHMWPE) is studied in the temperature range of 23-80 degrees C. Samples are examined in quasi-static compression, tensile and creep tests to determine the accelerated deformation of UHMWPE at elevated temperatures. The deformation mechanisms under compression load can be described by one strain rate and temperature dependent Eyring process. The activation energy and volume of that process do not change between 23 degrees C and 50 degrees C. This suggests that the deformation mechanism under compression remains stable within this temperature range. Tribological tests are conducted to transfer this activated energy approach to the deformation behavior under loading typical for artificial knee joints. While this approach does not cover the wear mechanisms close to the surface, testing at higher temperatures is shown to have a significant potential to reduce the testing time for lifetime predictions in terms of the macroscopic creep and deformation behavior of artificial joints. Copyright 2010. Published by Elsevier Ltd.

  11. Commentary on the management of type II odontoid process fractures in octogenarians: Article by Graffeo et al. and Editorial by Falavigna (J Neurosurgery Spine August 19, 2016).

    Science.gov (United States)

    Epstein, Nancy E

    2016-01-01

    Establishing a clear treatment paradigm for octogenarians with type II odontoid fractures in hampered by a literature replete with level III articles. In the study by Graffeo et al ., the authors evaluated 111 patients over the age of 79 (average age: 87) with type II odontoid fractures undergoing nonoperative (94 patients) vs. operative intervention (17 total; 15 posterior and 2 anterior). They studied multiple variables and utilized several scales [abbreviated injury scale (AIS), injury severity score (ISS), and the Glasgow coma scale (GCS)] to determine the outcomes of nonoperative vs. operative management. Graffeo et al . concluded that there were no significant differences between nonoperative and operative management for type II odontoid fractures in octogenarians. They found similar frequencies of additional cervical fractures, mechanisms of injury, GCS of 8 or under, AIS/ISS scores, and disposition to "nonhome" facilities. Furthermore, both appeared to have increased mortality rates at 1-year post injury; 13% during hospitalization, 26% within the first post-injury month, and 41% at 1 year. In the editorial by Falavigna, his major criticism of Graffeo's article was the marked disparity in the number of patients in the operative (17 patients) vs. the nonoperative group (94 patients), making it difficult to accept any conclusions as "significant". He further noted that few prior studies provided level I evidence, and that most, like this one, were level III analyses that did not "significantly" advance our knowledge as to whether to treat octogenarians with type II odontoid fractures operatively vs. nonoperatively.

  12. [Application of anterior percutaneous screw fixation in treatment of odontoid process fractures in aged people].

    Science.gov (United States)

    Luo, Peng; Dou, Hai-cheng; Ni, Wen-fei; Huang, Qi-shan; Wang, Xiang-yang; Xu, Hua-zi; Chi, Yong-long

    2011-03-01

    To explore the efficacy of anterior percutaneous screw fixation in the treatment of odontoid process fractures in aged people. From February 2001 to April 2009, 15 elderly patients with odontoid fracture were treated with anterior percutaneous screw fixation,including 13 males and 2 females; the average age was 69.3 years (ranged, 60 to 86 years). According to Anderson classification, there were 10 patients with type II fractures (type II A in 7 cases, type II B in 3 cases, based on Eysel and Roosen classification), 4 patients with shallow type III fractures, 1 patient with deep type III fractures. Thirteen patients were fresh fractures, 2 patients were obsolete fractures. All patients had varying degrees of neck or shoulder pain, and limit activity of neck. There were 4 patients with neural symptoms including 2 grade D and 2 grade C according to Frankel classification. All the patients were followed up and were assessed by radiology. Clinical examination included neck activity, neurological function and the degree of neck pain. Radiology examinations including anteroposterior, lateral, open mouth position and flexion-extension radiographs of cervical vertebra were performed. After surgery, all patients were followed up,and the duration ranged from 6 to 60 months (averaged 31.3 months). Two patients died of other diseases during the follow-up period (18 and 22 months after surgery respectively). All patients got satisfactory results, and all screws were in good position. As the screw was too long, esophagus was compressed by screw tail in one case. One case showed fibrous union, 12 cases had achieved solid bony union, 2 cases showed nonunion without clinical symptoms. The rotation of neck in 3 cases was mildly limited,the neck function of the remaining patients were normal. Four patients with symptoms nerve injuries improved after operation (Frankel E in 3 cases, Frankel D in 1 case). The symptom of neck pain had a significant improvement after surgery (P process

  13. Strontium-doped calcium polyphosphate/ultrahigh molecular weight polyethylene composites: A new class of artificial joint components with enhanced biological efficacy to aseptic loosening

    International Nuclear Information System (INIS)

    Gu, Zhipeng; Huang, Bingxue; Li, Yiwen; Tian, Meng; Li, Li; Yu, Xixun

    2016-01-01

    To enhance implant stability and prolong the service life of artificial joint component, a new approach was proposed to improve the wear resistance of artificial joint component and endow artificial joint component with the biological efficacy of resistance to aseptic loosening. Strontium calcium polyphosphate (SCPP) were interfused in ultrahigh molecular weight polyethylene (UHMWPE) by a combination of liquid nitrogen ball-milling and flat-panel curing process to prepare the SCPP/UHMWPE composites. The micro-structure, mechanical characterization, tribological characterization and bioactivities of various SCPP/UHMWPE composites were investigated. The results suggested that this method could statistically improve the wear resistance of UHMWPE resulting from a good SCPP particle dispersion. Moreover, it is also observed that the SCPP/UHMWPE composites-wear particles could promote the production of OPG by osteoblasts and decrease the production of RANKL by osteoblasts, and then increase the OPG/RANKL ratio. This indicated that the SCPP/UHMWPE composites had potential efficacy to prevent and treat aseptic loosening. Above all, the SCPP/UHMWPE composites with a suitable SCPP content would be the promising materials for fabricating artificial joint component with ability to resist aseptic loosening. - Highlights: • SCPP/UHMWPE composites could enhance biological efficacy of resistance to aseptic loosening. • SCPP would improve biological efficacy with a few sacrifice of wear resistance. • The results might provide a promising wear-resistant material for fabricating acetabular cup.

  14. Strontium-doped calcium polyphosphate/ultrahigh molecular weight polyethylene composites: A new class of artificial joint components with enhanced biological efficacy to aseptic loosening

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Zhipeng [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China); Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu 610041 (China); Huang, Bingxue; Li, Yiwen [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China); Tian, Meng [Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu 610041 (China); Li, Li [Department of Oncology, the 452 Hospital of Chinese PLA, Chengdu 610021 (China); Yu, Xixun, E-mail: yuxixun@163.com [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China)

    2016-04-01

    To enhance implant stability and prolong the service life of artificial joint component, a new approach was proposed to improve the wear resistance of artificial joint component and endow artificial joint component with the biological efficacy of resistance to aseptic loosening. Strontium calcium polyphosphate (SCPP) were interfused in ultrahigh molecular weight polyethylene (UHMWPE) by a combination of liquid nitrogen ball-milling and flat-panel curing process to prepare the SCPP/UHMWPE composites. The micro-structure, mechanical characterization, tribological characterization and bioactivities of various SCPP/UHMWPE composites were investigated. The results suggested that this method could statistically improve the wear resistance of UHMWPE resulting from a good SCPP particle dispersion. Moreover, it is also observed that the SCPP/UHMWPE composites-wear particles could promote the production of OPG by osteoblasts and decrease the production of RANKL by osteoblasts, and then increase the OPG/RANKL ratio. This indicated that the SCPP/UHMWPE composites had potential efficacy to prevent and treat aseptic loosening. Above all, the SCPP/UHMWPE composites with a suitable SCPP content would be the promising materials for fabricating artificial joint component with ability to resist aseptic loosening. - Highlights: • SCPP/UHMWPE composites could enhance biological efficacy of resistance to aseptic loosening. • SCPP would improve biological efficacy with a few sacrifice of wear resistance. • The results might provide a promising wear-resistant material for fabricating acetabular cup.

  15. Fractures of the atlantoaxial complex in the elderly: assessment of radiological spectrum of fractures and factors influencing imaging diagnosis; Frakturen des Atlas und Axis bei aelteren Patienten: Untersuchung des Radiologischen Spektrums der Frakturen und bedeutsamer Faktoren fuer die Bildgebende Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Lomoschitz, F.M. [Universitaetsklinik fuer Radiodiagnostik, AKH Wien, Wien (Germany); Dept. of Radiology, Harborview Medical Center, Univ. of Washington, Seattle, WA (United States); Blackmore, C.C.; Linnau, K.F.; Mann, F.A. [Dept. of Radiology, Harborview Medical Center, Univ. of Washington, Seattle, WA (United States); Stadler, A. [Universitaetsklinik fuer Radiodiagnostik, AKH Wien, Wien (Germany)

    2004-02-01

    Objective: to describe patterns of atlantoaxial fractures in a population of consecutive elderly patients, including assessment of type, distribution and associated clinical and radiological findings, and to analyze any influence of the causative trauma mechanism on the individual fracture pattern. Materials and methods: the distribution and type of 123 atlantoaxial fractures in 95 subjects older than 65 years (range: 65-102; mean age: 79 years) were retrospectively assessed. For each subject, trauma mechanism and clinical and neurological status were recorded at admission. Initial imaging studies of the cervical spine were reviewed. Preexistent degenerative changes were assessed and the atlantoaxial fractures classified. Data were evaluated for the frequency of different types of fractures of C1 and C2 and for accompanying fractures of cervical vertebrae or the occipital condyles, respectively. Results: the majority of patients with injuries of the atlantoaxial complex had fractures of C2 (90 of 95, 95%). A large proportion of these patients (67 of 90, 74%) had odontoid fractures. An isolated fracture of C1 was present in only 5 (5%) patients. Associated fractures of the occipital condyles or other cervical vertebrae were rare (10 of 95, 11%). The main trauma mechanism for atlantoaxial injuries was a fall (56 of 95, 59%). Elderly patients injured in motor vehicle accidents were more likely to have isolated fractures of C2 and Type III fractures of the odontoid (p < 0.02). Conclusion: in elderly patients, fractures of the atlantoaxial complex are mainly caused by falls and almost always involve C2. The trauma mechanism influences the fracture pattern (orig.) [German] Untersuchung von Frakturen des Atlas (C1) und Axis (C2) in einer konsekutiven Population aelterer Patienten ({>=} 65 Jahre) hinsichtlich Fraktur-Typus, -Haeufigkeit, und -Kombinationen, und Analyse von assoziierter Klinik sowie Einfluss von unfall-ursaechlichen Faktoren auf Frakturen des atlanto

  16. The impact of surface and geometry on coefficient of friction of artificial hip joints.

    Science.gov (United States)

    Choudhury, Dipankar; Vrbka, Martin; Mamat, Azuddin Bin; Stavness, Ian; Roy, Chanchal K; Mootanah, Rajshree; Krupka, Ivan

    2017-08-01

    Coefficient of friction (COF) tests were conducted on 28-mm and 36-mm-diameter hip joint prostheses for four different material combinations, with or without the presence of Ultra High Molecular Weight Polyethylene (UHMWPE) particles using a novel pendulum hip simulator. The effects of three micro dimpled arrays on femoral head against a polyethylene and a metallic cup were also investigated. Clearance played a vital role in the COF of ceramic on polyethylene and ceramic on ceramic artificial hip joints. Micro dimpled metallic femoral heads yielded higher COF against a polyethylene cup; however, with metal on metal prostheses the dimpled arrays significantly reduced the COF. In situ images revealed evidence that the dimple arrays enhanced film formation, which was the main mechanism that contributed to reduced friction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Rare location of spondylitis tuberculosis;atlanto-axial, sacral and cervico-thoracic junction

    Science.gov (United States)

    Victorio; Nasution, M. D.; Ibrahim, S.; Dharmajaya, R.

    2018-03-01

    Three cases of rare location spondylitis tuberculosis are reported, each in atlantoaxial, cervico-thoracic junction,and sacral. The complaints were aweakness of motoric strength and local back pain. Patients’thoracal x-ray was normal, there was no complaint of acough, PCR forTB was early diagnostic and positive in all three cases, HIV negative, intraoperative tissue samplings were sent for histopathology examination and the results showed thespecific inflammatory process. Lesions were evaluated with computer tomography and/or MRI imaging.Preoperative TB regimens therapy were given for 2 weeks and continued for nine months. The surgical procedurewas done in all cases with excellent improvement of symptoms and motoric strength. In our institution,25 cases of total TB spondylitis were performed in 2 years, only 1 case eachwas found in atlanto-axial, cervico-thoracic and sacral.

  18. A Novel Design for Adjustable Stiffness Artificial Tendon for the Ankle Joint of a Bipedal Robot: Modeling & Simulation

    Directory of Open Access Journals (Sweden)

    Aiman Omer

    2015-12-01

    Full Text Available Bipedal humanoid robots are expected to play a major role in the future. Performing bipedal locomotion requires high energy due to the high torque that needs to be provided by its legs’ joints. Taking the WABIAN-2R as an example, it uses harmonic gears in its joint to increase the torque. However, using such a mechanism increases the weight of the legs and therefore increases energy consumption. Therefore, the idea of developing a mechanism with adjustable stiffness to be connected to the leg joint is introduced here. The proposed mechanism would have the ability to provide passive and active motion. The mechanism would be attached to the ankle pitch joint as an artificial tendon. Using computer simulations, the dynamical performance of the mechanism is analytically evaluated.

  19. Brachygnathia superior and degenerative joint disease: a new lethal syndrome in Angus calves.

    Science.gov (United States)

    Jayo, M; Leipold, H W; Dennis, S M; Eldridge, F E

    1987-03-01

    Brachygnathia superior and generalized diarthrodial degenerative joint disease were seen in 17 related, purebred Angus calves ranging in age from 2 days to 4 months. Craniometrical studies revealed decreased maxillary and palatine bone lengths and increased cranial, skull, and facial indices. Radiological evaluation of major appendicular joints demonstrated lipping of the joint margins with osteophyte formation, sclerosis of subchondral bone, and narrowing of joint spaces. Synovial fluid evaluation indicated joint degeneration but no etiologic agent. Rheumatoid factor analysis of plasma was negative. Grossly, all major appendicular joints were defective including the atlanto-occipital articulation. Lesions ranged from loss of surface luster to erosions and deep ulcers with eburnation of the subchondral bone and secondary proliferative synovitis. Histological changes were degeneration of the articular cartilage matrix, chondrocyte necrosis, flaking and fibrillation, chondrone formation, erosions and ulcers of the articular cartilage with subchondral bone sclerosis, vascular invasion with fibrosis, and chronic, nonsuppurative, proliferative synovitis. Growth plates had defective chondrocyte proliferation and hypertrophy with aberrant ossification of calcified cartilaginous matrix. Histochemical analysis of cartilage and bone failed to incriminate which component was defective, glycosaminoglycan or collagen, but indicated different distribution or absence of one or the other. Genealogic studies revealed a genetic basis for the new defect.

  20. Case report 400: Unilateral fusion of odontoid to lateral mass of C1 with pseudoarthrosis on left

    Energy Technology Data Exchange (ETDEWEB)

    Nyska, M; Margulies, J Y; Gomori, J M; Beauvoir, G

    1986-11-01

    A case is described of a 19-year-old woman who presented with pain in the neck of several months duration. Torticolis and limitation of rotation of the head and neck to the right were observed. Plain films of the cervical spine were interpreted as normal, but plain film tomography and CT studies demonstrated an unusual anomaly, consisting of fusion of the odontoid process to the right lateral mass of C1 and a pseudoarthrosis in the anterior mass on the left side. (orig./SHA).

  1. A review of clinical and radiological aspects of rheumatoid arthritis of head joints

    International Nuclear Information System (INIS)

    Schilling, F.

    1987-01-01

    The most important inflammations--rheumatic joint diseases of the vertebral column--are chronic polyarthritis (rheumatoid arthritis) with involvement of cervical vertebral and atlanto-axial dislocation and ankylosing spondylitis (Bechterew's disease) resp. the seronegative spondylarthritis. A decisive and important difference between both forms of disease is found in the region of the cervical part of the vertebral column. In case of a spondylarthritis (ASp.) the ankylopoietica type includes the cervical vertebrae but the chronic polyarthritis (RA) is usually limited to the cervical vertebral spine. The incidence in both types (RA) is usually limited to the cervical vertebral spine. The incidence in both types (RA and ASp.) of cervical involvement is about 30%. The authors present an account of the underlying disease process. A description of rheumatoid cervical arthritis is given. The destructive and dislocating arthritis of the cranio-cervical function (arthritis of the head and neck joints) is described

  2. Anesthetic management of a child with Down’s Syndrome having atlanto axial instability

    Directory of Open Access Journals (Sweden)

    Basant Bhattarai

    2009-01-01

    Full Text Available Down's syndrome is the most commonly encountered congenital anomaly in medical practice. These patients are of special concern to medical practice because of their associated problems with regard to respiratory, cardiovascular and other systemic problems. As these patients present for repeated surgeries like dental extraction, facial reconstruction and fixation of cervical spine, these patients pose challenges to the anesthesiologist because of their unique set of problems, namely atlantoaxial instability, small trachea, congenital heart disease and repeated chest infections due to lowered immunity. Their reactivity to inhalational anesthetics and atropine is variable. Here we present an interesting case report of a child with Down's syndrome who presented with atlantoaxial instability for MRI of cervical spine under general anesthesia. KeyWords:atlanto axial instability, down’s syndrome, trisomy 21

  3. Patterned CoCrMo and Al2 O3 surfaces for reduced free wear debris in artificial joint arthroplasty.

    Science.gov (United States)

    Tarabolsi, Mohamad; Klassen, Thomas; Mantwill, Frank; Gärtner, Frank; Siegel, Frank; Schulz, Arndt-Peter

    2013-12-01

    Surface wear of corresponding tribological pairings is still a major problem in the application of artificial joint surgery. This study aims at developing wear reduced surfaces to utilize them in total joint arthroplasty. Using a pico-second laser, samples of medical CoCrMo metal alloy and Al2 O3 ceramic were patterned by laser material removal. The subsequent tribological investigations employed a ring-on-disc method. The results showed that those samples with modified surfaces show less mass or volume loss than those with a regular, smooth surface. Using calf serum as lubricating medium, the volume loss of the structured CoCrMo samples was eight times lower than that of regular samples. By structuring Al2 O3 surfaces, the wear volume could be reduced by 4.5 times. The results demonstrate that defined surface channels or pits enable the local sedimentation of wear debris. Thus, the amount of free debris could be reduced. Fewer abrasives in the lubricated so-called three-body-wear between the contact surfaces should result in less surface damage. Apart from direct influences on the wear behavior, less amounts of free debris of artificial joints should also be beneficial for avoiding undesired reactions with the surrounding soft tissues. The results from this study are very promising. Future investigations should involve the use of simulators meeting the natural conditions in the joint and in vivo studies with living organisms. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  4. An ankle-foot orthosis powered by artificial pneumatic muscles.

    Science.gov (United States)

    Ferris, Daniel P; Czerniecki, Joseph M; Hannaford, Blake

    2005-05-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury.

  5. Comparison of Venous Thromboembolism after Total Artificial Joint Replacement between Musculoskeletal Tumors and Osteoarthritis of the Knee by a Single Surgeon.

    Directory of Open Access Journals (Sweden)

    Dong Fu

    Full Text Available The purpose of this study was to compare and evaluate the event of VTE (Venous Thromboembolism Event after total artificial joint replacement between two groups diagnosed with either musculoskeletal tumors or osteoarthritis (OA of the knee. From 2004 to 2014, a total of 1,402 patients (308 in tumor group, 1,094 in OA group were involved in this study. The rate of asymptomatic DVT (Deep vein thrombosis was significantly higher in tumor group when compared with OA group. Though both the incidence of symptomatic DVT and PE (Pulmonary embolism were slightly higher in tumor group, no significant difference was detected. Tumor patients suffered an almost equal risk of VTE compared with OA patients except a higher rate of asymptomatic DVT after total artificial joint replacement. For patients with tumor, no significant association was observed between any potential risk factor and DVT.

  6. The effect of sliding velocity on the mechanical response of an artificial joint in Topopah Spring Member tuff

    International Nuclear Information System (INIS)

    Olsson, W.A.

    1994-04-01

    A smooth artificial joint in Topopah Spring Member tuff was sheared at constant normal stress at velocities from 0 to 100 μm/s to determine the velocity-dependence of shear strength. Two different initial conditions were used: (1) unprimed -- the joint had been shear stress-free since last application of normal stress, and before renewed shear loading; and (2) primed -- the joint had undergone a slip history after application of normal stress, but before the current shear loading. Observed steady-state rate effects were found to be about 3 times lager than for some other silicate rocks. These different initial conditions affected the character of the stress-slip curve immediately after the onset of slip. Priming the joint causes a peak in the stress-slip response followed by a transient decay to the steady-state stress, i.e., slip weakening. Slide-hold-slide tests exhibit time-dependent strengthening. When the joint was subjected to constant shear stress, no slip was observed; that is, joint creep did not occur. One set of rate data was collected from a surface submerged in tap water, the friction was higher for this surface, but the rate sensitivity was the same as that for surfaces tested in the air-dry condition

  7. Congenital Spondylolytic Spondylolisthesis of C2 Vertebra Associated With Atlanto-Axial Dislocation, Chiari Type I Malformation, and Anomalous Vertebral Artery: Case Report With Review Literature.

    Science.gov (United States)

    Sardhara, Jayesh; Pavaman, Sindgikar; Das, Kuntal; Srivastava, Arun; Mehrotra, Anant; Behari, Sanjay

    2016-11-01

    Congenital spondylolytic spondylolisthesis of C2 vertebra resulting from deficient posterior element of the axis is rarely described in the literature. We describe a unique case of agenesis of posterior elements of C2 with craniovertebral junction anomalies consisting of osseous, vascular, and soft tissue anomalies. A 26-year-old man presented with symptoms of upper cervical myelopathy of 12 months' duration. A computed tomography scan of the cervical spine including the craniovertebral junction revealed spondylolisthesis of C2 over C3, atlantoaxial dislocation, occipitalization of the atlas, hypoplasia of the odontoid, and cleft posterior C1 arch. Additionally, the axis vertebra was found devoid of its posterior elements except bilaterally rudimentary pedicles. Magnetic resonance imaging revealed tonsilar herniation, suggesting associated Chiari type I malformation. CT angiogram of the vertebral arteries displayed persistent bilateral first intersegmental arteries crossing the posterior aspect of the C1/2 facet joint. This patient underwent foramen magnum decompression, C3 laminectomy with occipito-C3/C4 posterior fusion using screw and rod to maintain the cervical alignment and stability. We report this rare constellation of congenital craniovertebral junction anomaly and review the relevant literature. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Pneumatic Artificial Muscles Force Modelling and the Position and Stiffness Control on the Knee Joint of the Musculoskeletal Leg

    Directory of Open Access Journals (Sweden)

    Jingtao Lei

    2017-03-01

    Full Text Available Pneumatic artificial muscles (PAMs have properties similar to biological muscle and are widely used in robotics as actuators. A musculoskeletal leg mechanism driven by PAMs is presented in this paper. The joint stiffness of the musculoskeletal bionic leg for jumping movement needs to be analysed. The synchronous control on the position and stiffness of the joint is important to improve the flexibility of leg. The accurate force model of PAM is the foundation to achieving better control and dynamic jumping performance. The experimental platform of PAM is conducted, and the static equal pressure experiments are performed to obtain the PAM force model. According to the testing data, parameter identification method is adopted to determine the force model of PAM. A simulation on the position and stiffness control of the knee joint is performed, and the simulation results show the effectiveness of the presented method.

  9. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    Science.gov (United States)

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  10. Enhanced lubricant film formation through micro-dimpled hard-on-hard artificial hip joint: An in-situ observation of dimple shape effects.

    Science.gov (United States)

    Choudhury, Dipankar; Rebenda, David; Sasaki, Shinya; Hekrle, Pavel; Vrbka, Martin; Zou, Min

    2018-05-01

    This study evaluates the impact of dimple shapes on lubricant film formation in artificial hip joints. Micro-dimples with 20-50 µm lateral size and 1 ± 0.2 µm depths were fabricated on CrCoMo hip joint femoral heads using a picosecond laser. Tribological studies were performed using a pendulum hip joint simulator to apply continuous swing flexion-extension motions. The results revealed a significantly enhanced lubricant film thickness (≥ 500 nm) with micro-dimpled prosthesis heads at equilibrium position after the lubricant film has fully developed. The average lubricant film thickness of dimpled prostheses with square- and triangular-shaped dimple arrays over time is about 3.5 that of the non-dimpled prosthesis (204 nm). Remarkably, the prosthesis with square-shaped dimple arrays showed a very fast lubricant film formation reaching their peak values within 0.5 s of pendulum movement, followed by prosthesis with triangular-shaped dimple arrays with a transition period of 42.4 s. The fully developed lubricant film thicknesses (≥ 700 nm) are significantly higher than the surface roughness (≈ 25 nm) demonstrating a hydrodynamic lubrication. Hardly any scratches appeared on the post-experimental prosthesis with square-shaped dimple array and only a few scratches were found on the post-experimental prosthesis with triangular-shaped dimple arrays. Thus, prostheses with square-shaped dimple arrays could be a potential solution for durable artificial hip joints. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. The odontoid synchondrotic slip: an injury unique to young children

    International Nuclear Information System (INIS)

    Connolly, B.; Emery, D.; Armstrong, D.

    1995-01-01

    We report seven children (three female, four male) diagnosed with traumatic synchrondrotic slip of the odontoid. The clinical records, plain films, and CT scans were evaluated retrospectively. The patients ranged in age between 3 and 5 years. Their injuries resulted from a motor vehicle accident in four cases and from a fall from a height in three. The injury was isolated in five; it was associated with a closed head injury in one and with facial and brachial plexus trauma in another. Radiographs showed anterior angulation with or without displacement in all seven cases. Axial CT with sagittal reformation and 3D reconstructions were performed in six cases. This confirmed the synchrondrotic slip and, in addition, identified a rotary component to the injury in three cases, with compromise of the canal in two. Other additional injuries were also noted. All cases were treated conservatively and the injuries healed. Only one child had a neurological deficit attributable to her head injury rather than to her cervical injury (MR of the cervical cord was normal). The presence of the synchondrosis between the dens and the body of C-2 makes this injury unique to children under 7 years of age; by the age of 7 the synchrondrosis has fused. (orig.)

  12. MRI diagnosis of suspected atlanto-occipital dissociation in childhood

    International Nuclear Information System (INIS)

    Grabb, B.C.; Frye, T.A.; Hedlund, G.L.; Vaid, Y.N.; Royal, S.A.; Grabb, P.A.

    1999-01-01

    Objective. To demonstrate the utility of magnetic resonance (MR) imaging in the diagnosis of complete and partial ligamentous injuries in patients with suspected atlanto-occipital dissociation (AOD). Materials and methods. Five patients with suspected AOD had MR imaging performed within an average of 4 days after injury. MR scans were reviewed with specific analysis of craniocervical ligamentous structures. Charts were reviewed to obtain clinical information regarding presentation, treatment, hospital course, and outcome. Results. Two patients demonstrated MR evidence of complete AOD. One had disruption of all visualized major ligamentous structures at the craniocervical junction with anterolisthesis and evidence of cord damage. The second had injuries to the tectorial membrane, superior band of the cruciform ligament, apical ligament, and interspinous ligament at C 1-2. The remaining three patients sustained incomplete severance of the ligamentous structures at the craniocervical junction. All patients demonstrated subtle radiographic findings suggestive of AOD, including soft tissue swelling at the craniocervical junction without fracture. The two patients with complete AOD died. The three patients with partial AOD were treated with stabilization. On follow-up, these three children were asymptomatic following their craniocervical injury. Conclusion. MR imaging of acute AOD provides accurate identification of the craniocervical ligaments injured, classification of full versus partial ligamentous disruption, and analysis of accompanying spinal cord injury. This information is important for early appropriate neurosurgical management and preservation of neurologic function in survivors. (orig.)

  13. The radiologic spectrum of occipital condyle fractures

    International Nuclear Information System (INIS)

    Hanson, J.A.; Deliganis, A.V.; Baxter, A.B.; Cohen, W.A.; Wilson, A.J.; Mann, F.A.

    2002-01-01

    Full text: Occipital condyle fractures (OCFs) are increasingly diagnosed in survivors of high energy blunt trauma, and may be associated with craniocervical junction disruption.We aimed to describe and classify the imaging appearances of occipital condyle fractures in a large series of trauma patients. We reviewed conventional radiographs, computed tomography (CT), and magnetic resonance (MR) imaging in 95 patients with 107 OCFs, who were treated at a level 1 trauma centre (1992-1999). We described fracture patterns according to two current classification systems (Anderson and Montesano, and Tuli), and correlated imaging appearances with clinical findings, neurosurgical management and patient outcome. Fracture morphology and craniocervical junction integrity were best assessed by 1-1.5mm collimation CT. Inferomedial occipital condyle avulsion fractures (Anderson and Montesano type III) were the commonest OCF category, comprising 80/107 (75%). Unilateral OCFs were found in 73/95 (77%) patients, 58 of whom were managed by cervical orthotic brace or collar. Bilateral OCFs or occipito-atlanto-axial joint injuries were seen in the remaining 22/95 (23%) patients. Occipitocervical fusion or craniocervical halo traction were required in 12 patients, all of whom had CT evidence of bilateral occipito-atlanto-axial joint disruption. Associated cervical spine injuries were present in 29/95 (31%) patients. Ten (10/95, 10.5%) patients died in hospital, and 30/95 (32%) showed continuing disability. The remaining 55/95 (57.5%) patients showed good outcome and functional independence at 1 month. Occipital condyle fractures are rare injuries with a wide range of morphology, stability and clinical significance. Thorough radiological evaluation of all components of the occipito-atlanto-axial joint complex must be performed in order to determine the full extent of injury. In this series, most unilateral OCFs were managed by non-operative immobilisation, whereas bilateral occipito-atlanto

  14. Congenital defects of C1 arches and odontoid process in a child with Down′s syndrome: A case presentation

    Directory of Open Access Journals (Sweden)

    Catherine Hatzantonis

    2016-01-01

    Full Text Available We present the case of a 2-year-old child with Down′s syndrome who presented to our unit with torticollis. Imaging studies revealed the rare occurrence of anterior and posterior C1 arch defects, absent odontoid process, and atlantoaxial subluxation. We managed her conservatively for 3 years without neurological deficits or worsening of atlantoaxial subluxation. We discuss the rare occurrences of anterior and posterior arch defects of the atlas, the radiological presentations of axis defects in patients, and the occurrence of atlantoaxial instability in patients with Down′s syndrome. Management options with consideration to surgery in asymptomatic and symptomatic patients are also discussed.

  15. Anatomic variation of the deep venous system and its relationship with deep vein thrombosis found on the lower extremity venograms that were obtained after artificial joint replacements

    International Nuclear Information System (INIS)

    Lee, Min Sun; Lee, Jee Eun; Hwang, Ji Young; Shim, Sung Shine; Yoo, Jeong Hyun; Suh, Jeong Soo; Park, Jae Young

    2006-01-01

    We wanted to evaluate the anatomic variations, the number of valves and the presence of deep vein thrombosis (DVT) on the lower extremity venograms obtained after artificial joint replacements, and we also wanted to determine the correlation of the incidence of DVT with the above-mentioned factors and the operation sites. From January to June 2004, conventional ascending contrast venographies of the lower extremities were performed in 119 patients at 7-10 days after artificial joint replacement, and all the patients were asymptomatic. Total knee replacement was done for 152 cases and total hip replacement was done for 34 cases. On all the venographic images of 186 limbs, the anatomic variations were classified and the presence of DVT was evaluated; the number of valves in the superficial femoral vein (SFV) and calf veins was counted. The sites of DVT were classified as calf, thigh and pelvis. Statistically, chi square tests and Fischer's exact tests were performed to determine the correlation of the incidence of DVT with the anatomic variations, the numbers of valves and the operation sites. Theoretically, there are 9 types of anatomical variation in the deep vein system of the lower extremity that can be classified, but only 7 types were observed in this study. The most frequent type was the normal single SFV type and this was noted in 117 cases (63%), and the others were all variations (69 cases, 37%). There was a 22.2% incidence of DVT (69 cases) in the normal single SFV type and 26.4% (17 cases) in the other variations. No significant difference was noted in the incidences of DVT between the two groups. In addition, no significant statistical differences were noted for the incidences of DVT between the single or variant multiple veins in the SFV and the popliteal vein (PV) respectively, between the different groups with small or large numbers of valves in the thigh and calf, respectively, and also between the different operation sites of the hip or knee

  16. Posterior treatment of delayed traumatic atlantoaxial joint dislocation with apofix internal fixation

    International Nuclear Information System (INIS)

    Qing Wei; Jiang Weimin; Shi Jinhui; Li Xuefeng; Yang Huilin; Tang Tiansi

    2010-01-01

    Objective: To assess the effect of posterior fixation and fusion with Apofix device for the treatment of delayed traumatic atlantoaxial joint dislocation. Methods: Eighteen patients with delayed traumatic atlantoaxial joint dislocation were included. Posterior fixation and fusion with Apofix device were performed. First step was one or two week skull traction. After the atlantoaxial joint dislocation had been reduced, the posterior fixation and fusion with Apofix was performed. Using local anaesthesia, atlantoaxial interval and posterior structure of atlas and dentata were exposed by midline operative approach. Apofix interlaminar clamps were placed at posterior arch of atlas and odontoid vertebral laminae, autologous iliac bone graft was placed for fusion. Then the device to proper position was pressurized and items locked. Results: All of the patients were followed up, the mean follow-up period was 38 months (13 ∼ 84 months). Fifteen patients obtained complete reduction, the others were partial reduction. Seventeen patients had successful fusion after 3 or 4 months, only 1 patient who had partial reduction had internal fixation loose and nonfusion, leading to recurrence of atlantoaxial joint dislocation. An occipitocervical fusion surgery was performed on this patient. As to neurological assessment, 16 patients had neurological deficit before operation, while 6 of them recovered completely after operation, another 10 patients' neurological status improved significantly. JOA score was improved from 9.5 pre-operative to 15.8 post-operative. Conclusion: Apofix internal fixation and fusion seems to be feasible in treatment of delayed traumatic atlantoaxial joint dislocation. Successful reduction before operation and proper treatment after operation is also important. (authors)

  17. Progress and Challenge of Artificial Intelligence

    Institute of Scientific and Technical Information of China (English)

    Zhong-Zhi Shi; Nan-Ning Zheng

    2006-01-01

    Artificial Intelligence (AI) is generally considered to be a subfield of computer science, that is concerned to attempt simulation, extension and expansion of human intelligence. Artificial intelligence has enjoyed tremendous success over the last fifty years. In this paper we only focus on visual perception, granular computing, agent computing, semantic grid. Human-level intelligence is the long-term goal of artificial intelligence. We should do joint research on basic theory and technology of intelligence by brain science, cognitive science, artificial intelligence and others. A new cross discipline intelligence science is undergoing a rapid development. Future challenges are given in final section.

  18. Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems.

    Science.gov (United States)

    Su, Chen-Ying; Kuo, Chien-Wei; Fang, Hsu-Wei

    2017-01-01

    Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system.

  19. Radiologic evaluation of os odontoideum

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ju; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Kim, Yong Soo; Park, Hyoung Chun; Oh, Soung Hoon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-10-15

    We took an analysis on the clinical and radiologic findings of os odontoideum, which had been regarded as relatively uncommon disease, on 5 patients whom we have recently experienced. Our results were as follows: 1. Os odontoideums were incidentally discovered during the radiologic evaluation of traumatised 4 cases, who had been well being. Another one case of os odontoideum was associated with multiple epiphyseal dysplasia. 2. General radiologic findings of os odontoideum were a round or oval and hypoplastic ossicle separated from the base of odontoid process by wise gap. 3. Alanto-Axial instability was developed in 5 cases of os odontoideum by flexion and extension stress view of lateral cervical spine. 4. Flexion views of lateral cervical spine showed narrowing of anteroposterior diameter of spinal canal which were available at atlantoaxial level on 5 cases of os odontoidum. 5. CT myelogram and cervical myelogram showed anteriorly compressed dural sac and deformed spinal cord by body of axis at the atlanto-axial level.

  20. Biomaterials for artificial organs

    CERN Document Server

    Lysaght, Michael J

    2010-01-01

    The worldwide demand for organ transplants far exceeds available donor organs. Consequently some patients die whilst waiting for a transplant. Synthetic alternatives are therefore imperative to improve the quality of, and in some cases, save people's lives. Advances in biomaterials have generated a range of materials and devices for use either outside the body or through implantation to replace or assist functions which may have been lost through disease or injury. Biomaterials for artificial organs reviews the latest developments in biomaterials and investigates how they can be used to improve the quality and efficiency of artificial organs. Part one discusses commodity biomaterials including membranes for oxygenators and plasmafilters, titanium and cobalt chromium alloys for hips and knees, polymeric joint-bearing surfaces for total joint replacements, biomaterials for pacemakers, defibrillators and neurostimulators and mechanical and bioprosthetic heart valves. Part two goes on to investigate advanced and ...

  1. Respiratory pattern changes during costovertebral joint movement.

    Science.gov (United States)

    Shannon, R

    1980-05-01

    Experiments were conducted to determine if costovertebral joint manipulation (CVJM) could influence the respiratory pattern. Phrenic efferent activity (PA) was monitored in dogs that were anesthetized with Dial-urethane, vagotomized, paralyzed, and artificially ventilated. Ribs 6-10 (bilaterally) were cut and separated from ribs 5-11. Branches of thoracic nerves 5-11 were cut, leaving only the joint nerve supply intact. Manual joint movement in an inspiratory or expiratory direction had an inhibitory effect on PA. Sustained displacement of the ribs could inhibit PA for a duration equal to numerous respiratory cycles. CVJM in synchrony with PA resulted in an increased respiratory rate. The inspiratory inhibitory effect of joint receptor stimulation was elicited with manual chest compression in vagotomized spontaneously breathing dogs, but not with artificial lung inflation or deflation. It is concluded that the effect of CVJM on the respiratory pattern is due to stimulation of joint mechanoreceptors, and that they exert their influence in part via the medullary-pontine rhythm generator.

  2. Development and Physical Control Research on Prototype Artificial Leg

    Directory of Open Access Journals (Sweden)

    Fei Li

    2016-03-01

    Full Text Available To provide an ideal platform for research on intelligent bionic leg (IBL, this paper proposes a model of a biped robot with heterogeneous legs (BRHL. A prototype of an artificial leg is developed based on biological structure and motion principle analysis of human lower extremities. With regard to the driving sources, servomotors are chosen for the hip joint and ankle joint, while pneumatic muscle actuators (PMAs are chosen for the knee joint. The control system of the bionic artificial leg is designed and a physical experimental platform is established. The physical control experiments are done based on proportional-integral-derivative (PID control strategy. The experimental results show that such a system can realize the expected goals.

  3. The effect of sliding velocity on the mechanical response of an artificial joint in Topopah Spring Member tuff; Yucca Mountain Site Characterization Project

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, W.A.

    1994-04-01

    A smooth artificial joint in Topopah Spring Member tuff was sheared at constant normal stress at velocities from 0 to 100 {mu}m/s to determine the velocity-dependence of shear strength. Two different initial conditions were used: (1) unprimed -- the joint had been shear stress-free since last application of normal stress, and before renewed shear loading; and (2) primed -- the joint had undergone a slip history after application of normal stress, but before the current shear loading. Observed steady-state rate effects were found to be about 3 times lager than for some other silicate rocks. These different initial conditions affected the character of the stress-slip curve immediately after the onset of slip. Priming the joint causes a peak in the stress-slip response followed by a transient decay to the steady-state stress, i.e., slip weakening. Slide-hold-slide tests exhibit time-dependent strengthening. When the joint was subjected to constant shear stress, no slip was observed; that is, joint creep did not occur. One set of rate data was collected from a surface submerged in tap water, the friction was higher for this surface, but the rate sensitivity was the same as that for surfaces tested in the air-dry condition.

  4. Diagnóstico clínico e radiográfico de luxação traumática da articulação atlanto-occipital em dois cães

    Directory of Open Access Journals (Sweden)

    B.M. Araújo

    2013-02-01

    Full Text Available A luxação da articulação atlanto-occipital é considerada uma afecção incomum no homem e nos animais. Radiografias laterais são recomendadas para o diagnóstico. No entanto, estão sujeitas a erros relacionados ao ângulo de radiação, ao alvo da imagem, à distância e à sobreposição óssea. Objetivou-se neste relato descrever os achados clínicos e radiográficos de dois cães com luxação traumática da articulação atlanto-occipital que apresentavam tetraparesia, dor cervical cranial, incapacidade de elevar a cabeça e déficits de nervos cranianos. No primeiro animal, observaram-se deslocamento craniodorsal do processo articular do atlas em relação a um dos côndilos do occipital, ausência de sobreposição dos forames vertebrais laterais e sobreposição do côndilo do occipital ao processo articular do atlas, no lado direito, caracterizando uma luxação unilateral. No segundo animal, observou-se deslocamento craniodorsal dos processos articulares do atlas em relação aos côndilos do occipital, com sobreposição dos forames vertebrais laterais e ausência de visibilização dos côndilos do occipital em virtude da projeção cranial dos processos articulares do atlas em direção ao crânio, caracterizando luxação bilateral. Conclui-se que o exame radiográfico simples, nas projeções laterolateral e ventrodorsal, apesar da dificuldade de ser interpretado, é eficiente para confirmar o diagnóstico da luxação atlanto-occipital traumática, tanto a simétrica quanto a assimétrica.

  5. AtlantOS WP2, Enhancement of ship-based observing networks - Bathymetric integration and visualization of Europe's data holdings

    Science.gov (United States)

    Wölfl, Anne-Cathrin; Devey, Colin; Augustin, Nico

    2017-04-01

    The European Horizon 2020 research and innovation project AtlantOS - Optimising and Enhancing the Integrated Atlantic Ocean Observing Systems - aims to improve the present-day ocean observing activities in the Atlantic Ocean by establishing a sustainable, efficient and integrated Atlantic Ocean Observing System. 62 partners from 18 countries are working on solutions I) to improve international collaboration in the design, implementation and benefit sharing of ocean observing, II) to promote engagement and innovation in all aspects of ocean observing, III) to facilitate free and open access to ocean data and information, IV) to enable and disseminate methods of achieving quality and authority of ocean information, V) to strengthen the Global Ocean Observing System (GOOS) and to sustain observing systems that are critical for the Copernicus Marine Environment Monitoring Service and its applications and VI) to contribute to the aims of the Galway Statement on Atlantic Ocean Cooperation. The Work Package 2 of the AtlantOS project focuses on improving, expanding, integrating and innovating ship-based observations. One of the tasks is the provision of Europe's existing and future bathymetric data sets from the Atlantic Ocean in accessible formats enabling easy processing and visualization for stakeholders. Furthermore, a new concept has recently been implemented, where three large German research vessels continuously collect bathymetric data during their transits. All data sets are gathered and processed with the help of national data centers and partner institutions and integrated into existing open access data systems, such as Pangaea in Germany, EMODnet at European level and GMRT (Global Multi-Resolution Topography synthesis) at international level. The processed data will be linked to the original data holdings, that can easily be accessed if required. The overall aim of this task is to make bathymetric data publicly available for specialists and non-specialists both

  6. IJCAI-91 Workshop on Objects and Artificial Intelligence

    OpenAIRE

    Hatzilygeroudis, Ioannis

    1994-01-01

    The Objects and Artificial Intelligence Workshop was held on 25 August 1991 in conjunction with the 1991 International Joint Conference on Artificial Intelligence. The workshop brought together researchers in AI and object-oriented programming to exchange ideas and investigate possible avenues of cooperation between AI and object-oriented programming. The workshop dealt with both the theoretical and the practical aspects of this cooperation.

  7. Instrumented fusion in a 12-month-old with atlanto-occipital dislocation: case report and literature review of infant occipitocervical fusion.

    Science.gov (United States)

    Hale, Andrew T; Dewan, Michael C; Patel, Bhairav; Geck, Matthew J; Tomycz, Luke D

    2017-08-01

    The treatment of atlantoaxial dislocation in very young children is challenging and lacks a consensus management strategy. We review the literature on infantile occipitocervical (OC) fusion is appraised and technical considerations are organized for ease of reference. Surgical decisions such as graft type and instrumentation details are summarized, along with the use of bone morphogenic protein and post-operative orthoses. We present the case of a 12-month-old who underwent instrumented occipitocervical (OC) fusion in the setting of traumatic atlanto-occipital dislocation (AOD). Occipitocervical (OC) arthrodesis is obtainable in very young infants and children. Surgical approaches are variable and use a combination of autologous grafting and creative screw and/or wire constructs. The heterogeneity of pathologic etiology leading to OC fusion makes it difficult to make definitive recommendations for surgical management.

  8. Kinematic Analysis of 3-DOF Planer Robot Using Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Jolly Atit Shah

    2012-07-01

    Full Text Available Automatic control of the robotic manipulator involves study of kinematics and dynamics as a major issue. This paper involves the forward and inverse kinematics of 3-DOF robotic manipulator with revolute joints. In this study the Denavit- Hartenberg (D-H model is used to model robot links and joints. Also forward and inverse kinematics solution has been achieved using Artificial Neural Networks for 3-DOF robotic manipulator. It shows that by using artificial neural network the solution we get is faster, acceptable and has zero error.

  9. Artificial ligamentous joints:Methods, materials and characteristics

    OpenAIRE

    Hockings, Nick; Iravani, Pejman; Bowen, Chris

    2014-01-01

    This paper presents a novel method for making ligamentous articulations for robots. Ligamentous joints are widely found in animals, but they have been of limited appli- cation in robotics due to lack of analogous synthetic materials. The method presented combines 3D printing, tow laying and thermoplastic welding which enables manufacturing of this type of structure.

  10. Mechanical characterization of PVA hydrogel to be used as artificial joint cartilage reinforced by irradiation techniques

    International Nuclear Information System (INIS)

    Bavaresco, Vanessa Petrilli; Zavaglia, Cecilia A.C.; Reis, Marcelo de Carvalho

    2002-01-01

    Crosslinked networks of polyvinyl alcohol (PVA) produced from PVA aqueous solution and induced by radiation has been recently developed, and their mechanical properties have been studied. These materials are too fragile to be useful for artificial joint cartilage applications, unless reinforced in some way. In this work, the mechanical resistance of PVA hydrogel produced by irradiation techniques was studied. Polyvinyl alcohol films from 15 and 20% w/w aqueous solutions were acetalized by immersing it in an acetalization bath containing aqueous formaldehyde, sulfuric acid and sodium sulfate anhydrous (60:50:300 g) at 60 deg C. The acetalized samples were irradiated (Dynamitron (E = 1,5 MeV)) with 25, 50, 75, 100 kGy doses. Hydrogel samples were characterized by indentation creep test and water swelling. The results obtained in this study suggest the improving of the mechanical properties of the hydrogel by the combination of acetalization and electron beam irradiation, without decreasing in the swelling properties. (author)

  11. Safety and surgical techniques of C1 lateral mass screws

    International Nuclear Information System (INIS)

    Kubo, Shinichiro; Kuroki, Hiroshi; Hanado, Shoji; Hamanaka, Hideaki; Inomata, Naoki; Kuroki, Shuji; Chosa, Etsuo

    2010-01-01

    The objectives of this study were to evaluate the proper insertion techniques of C1 lateral mass screws. Eighteen consecutive patients were examined after upper cervical fusion using twenty-nine C1 lateral mass screws. Screws were placed by three different techniques; Goel's technique (4), Tan's technique (20), Notching technique (5). Pre and post-operative CT scans with multiplanar reconstruction were used to detect cortical breaches and direction of screws. No transverse foramen and vertebral groove violation was found in CT scans. Three had breached superior articular facet of the atlas. However, the range of motion (R.O.M) of atlanto-occipital joints had not changed postoperatively. Theses screws were inserted with Tan's technique and two of three were directed medially. It is feasible to safely insert C1 lateral mass screws when correct insertion point and direction are considered preoperatively. However, care should be taken because screws can violate the atlanto-occipital joint especially with Tan's technique. (author)

  12. Prediction of the Vickers Microhardness and Ultimate Tensile Strength of AA5754 H111 Friction Stir Welding Butt Joints Using Artificial Neural Network.

    Science.gov (United States)

    De Filippis, Luigi Alberto Ciro; Serio, Livia Maria; Facchini, Francesco; Mummolo, Giovanni; Ludovico, Antonio Domenico

    2016-11-10

    A simulation model was developed for the monitoring, controlling and optimization of the Friction Stir Welding (FSW) process. This approach, using the FSW technique, allows identifying the correlation between the process parameters (input variable) and the mechanical properties (output responses) of the welded AA5754 H111 aluminum plates. The optimization of technological parameters is a basic requirement for increasing the seam quality, since it promotes a stable and defect-free process. Both the tool rotation and the travel speed, the position of the samples extracted from the weld bead and the thermal data, detected with thermographic techniques for on-line control of the joints, were varied to build the experimental plans. The quality of joints was evaluated through destructive and non-destructive tests (visual tests, macro graphic analysis, tensile tests, indentation Vickers hardness tests and t thermographic controls). The simulation model was based on the adoption of the Artificial Neural Networks (ANNs) characterized by back-propagation learning algorithm with different types of architecture, which were able to predict with good reliability the FSW process parameters for the welding of the AA5754 H111 aluminum plates in Butt-Joint configuration.

  13. Prediction of the Vickers Microhardness and Ultimate Tensile Strength of AA5754 H111 Friction Stir Welding Butt Joints Using Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Luigi Alberto Ciro De Filippis

    2016-11-01

    Full Text Available A simulation model was developed for the monitoring, controlling and optimization of the Friction Stir Welding (FSW process. This approach, using the FSW technique, allows identifying the correlation between the process parameters (input variable and the mechanical properties (output responses of the welded AA5754 H111 aluminum plates. The optimization of technological parameters is a basic requirement for increasing the seam quality, since it promotes a stable and defect-free process. Both the tool rotation and the travel speed, the position of the samples extracted from the weld bead and the thermal data, detected with thermographic techniques for on-line control of the joints, were varied to build the experimental plans. The quality of joints was evaluated through destructive and non-destructive tests (visual tests, macro graphic analysis, tensile tests, indentation Vickers hardness tests and t thermographic controls. The simulation model was based on the adoption of the Artificial Neural Networks (ANNs characterized by back-propagation learning algorithm with different types of architecture, which were able to predict with good reliability the FSW process parameters for the welding of the AA5754 H111 aluminum plates in Butt-Joint configuration.

  14. Evaluation of Rock Joint Coefficients

    Science.gov (United States)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    A computer method for evaluation of rock joint coefficients is described and several applications are presented. The method is based on two absolute numerical indicators that are formed by means of the Fourier replicas of rock joint profiles. The first indicator quantifies the vertical depth of profiles and the second indicator classifies wavy character of profiles. The absolute indicators have replaced the formerly used relative indicators that showed some artificial behavior in some cases. This contribution is focused on practical computations testing the functionality of the newly introduced indicators.

  15. Artificial Leg Design and Control Research of a Biped Robot with Heterogeneous Legs Based on PID Control Algorithm

    Directory of Open Access Journals (Sweden)

    Hualong Xie

    2015-04-01

    Full Text Available A biped robot with heterogeneous legs (BRHL is proposed to provide an ideal test-bed for intelligent bionic legs (IBL. To make artificial leg gait better suited to a human, a four-bar mechanism is used as its knee joint, and a pneumatic artificial muscle (PAM is used as its driving source. The static mathematical model of PAM is established and the mechanical model of a single degree of freedom of a knee joint driven by PAM is analyzed. A control simulation of an artificial leg based on PID control algorithm is carried out and the simulation results indicate that the artificial leg can simulate precisely a normal human walking gait.

  16. Design of a biped robot actuated by pneumatic artificial muscles.

    Science.gov (United States)

    Liu, Yixiang; Zang, Xizhe; Liu, Xinyu; Wang, Lin

    2015-01-01

    High compliant legs are essential for the efficient versatile locomotion and shock absorbency of humans. This study proposes a biped robot actuated by pneumatic artificial muscles to mimic human locomotion. On the basis of the musculoskeletal architecture of human lower limbs, each leg of the biped robot is modeled as a system of three segments, namely, hip joint, knee joint, and ankle joint, and eleven muscles, including both monoarticular and biarticular muscles. Each rotational joint is driven by a pair of antagonistic muscles, enabling joint compliance to be tuned by operating the pressure inside the muscles. Biarticular muscles play an important role in transferring power between joints. Walking simulations verify that biarticular muscles contribute to joint compliance and can absorb impact energy when the robot makes an impact upon ground contact.

  17. Role of imagining diagnostics in assessing the involvement of the cervical spine in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Cyrylowski, L.; Walecka, A.; Koryzma, A.; Brzosko, M.; Brzosko, I.; Prajs, K.

    2005-01-01

    Rheumatoid arthritis (RA) is a polyarthritis caused by inflammatory overgrowth of synnovium known as pannus. Small joints of hands and feet are most frequently involved, followed by cervical spine, particularly the craniocervical junction. The cervical spine involvement may be a cause of a range of neurological complications. Imaging diagnostics of the spine in RA patients include radiograms, CT and MRI. Their purposes is to evaluate type, extension and advancing of the changes. The following lesions can be found in the cervical spine at least in 30% of RA patients with disease duration more than 10 years: subaxial subluxations, apophyseal joint erosions, odontoid erosions, apophyseal joint sclerosis, intervertebral space narrowing, and osteophytosis.These lesions can be easily detected with radiographic examinations whereas the presence of the pannus can be found only with MRI or contrast enhanced CT. The most dangerous complication of RA in the cervical spine is atlantoaxial subluxation. It can be well demonstrated with MRI.Even it is frequently asymptomatic, there is always the possibility of neurological symptoms from compression of the spinal cord by the odontoid process. Therefore, MRI of the cervical spine should be considered in all RA patients. (author)

  18. A Case of Asymptomatic Occipital Condyle Fracture with Incomplete Occipitocervical Dislocation: How Did It Happen?

    Science.gov (United States)

    Anania, Pasquale; Fiaschi, Pietro; Sbaffi, Pier Filippo; Zona, Gianluigi

    2018-01-01

    Atlanto-occipital dislocation (AOD) is a lesion rarely observed in a trauma center, because of high mortality in the preclinical phase. The number of AOD survivors is increasing thanks to the improvement in prehospital resuscitation. Our goal is to describe a case of incomplete atlanto-occipital dislocation presented without any neurologic, cardiorespiratory, or metabolic problems, which remained constant even after surgical treatment. Our purpose is also to discuss treatment approaches to minimize subsequent neurologic deficits. We recommend a rapid immobilization with spine table and cervical collar, the consensual stabilization of hemodynamic and respiratory parameters, and a successive prompt occipitocervical stabilization. C2 should be included in the stabilization because of the ligamentous conformation of craniocervical joint. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Oblique Axis Body Fracture: An Unstable Subtype of Anderson Type III Odontoid Fractures—Apropos of Two Cases

    Directory of Open Access Journals (Sweden)

    Hirokazu Takai

    2016-01-01

    Full Text Available Purpose. Anderson type III odontoid fractures have traditionally been considered stable and treated conservatively. However, unstable cases with unfavorable results following conservative treatment have been reported. Methods. We present the cases of two patients who sustained minimally displaced Anderson type III fractures with a characteristic fracture pattern that we refer to as “oblique type axis body fracture.” Results. The female patients aged 90 and 72 years, respectively, were both diagnosed with minimally displaced Anderson type III fractures. Both fractures had a characteristic “oblique type” fracture pattern. The first patient was treated conservatively with cervical spine immobilization in a semirigid collar. However, gross displacement was noted at the 6-week follow-up visit. The second patient was therefore treated operatively by C1–C3/4 posterior fusion and the course was uneventful. Conclusions. Oblique type axis body fractures resemble a highly unstable subtype of Anderson type III fractures with the potential of severe secondary deformity following conservative treatment, irrespective of initial grade of displacement. The authors therefore warrant a high index of suspicion for this injury and suggest early operative stabilization.

  20. Atlantoaxial Rotatory Fixed Dislocation: Report on a Series of 32 Pediatric Cases.

    Science.gov (United States)

    Wang, Shenglin; Yan, Ming; Passias, Peter G; Wang, Chao

    2016-06-01

    Retrospective case series of atlantoaxial rotatory fixed dislocation (AARFD). To describe clinical features and the surgical treatment of AARFD. The classification and treatment strategy for atlantoaxial rotatory fixation (AARF) were previously described and remained controversial. AARF concomitant with atlantoaxial dislocation has different clinical features and treatment strategy with the most AARF. Due to deficiency of the transverse ligament or odontoid, the atlantoaxial remains unstable even after the torticollis relieved or cured. Because of the rarity, treatment strategy for this special condition has not been specialized and fully explored in the literatures. Thirty-two children with AARFD (sustained torticollis more than 6 weeks and atlanto-dental internal more than 5 mm) were retrospectively reviewed. Treatment methodology, pearls, and pitfalls of the treatment were discussed. Thirty-two cases had sustained torticollis for an average of 5.7 months. ADI of them ranged from 8 to 22 mm, with a mean of 11.3 mm. Eight cases presented with signs and symptoms of spinal cord dysfunction. All 32 cases underwent surgery and had no spinal cord or vertebral artery injury. The surgery included posterior reduction and fusion (reducible dislocation and torticollis, 16 cases), and transoral release followed by posterior reduction and fusion (irreducible dislocation and torticollis, 16 cases). The average follow-up time was 42 months. Solid fusion and torticollis healing were achieved in 31 patients (96.9%) as detected radiologically. Two cases (6.3%, 2/32) suffered complications (cerebrospinal fluid leakage and recurred torticollis followed by revision). AARFD had distinct clinical features relative to common presentations of AARF. Because of deficiency of the transverse ligament or odontoid and subsequent atlantoaxial dislocation, surgical treatments are applied for this condition, including transoral release and posterior C1-2 reduction and fusion. AARFD cases

  1. The Joint Tactical Aerial Resupply Vehicle Impact on Sustainment Operations

    Science.gov (United States)

    2017-06-09

    Artificial Intelligence , Sustainment Operations, Rifle Company, Autonomous Aerial Resupply, Joint Tactical Autonomous Aerial Resupply System 16...Integrations and Development System AI Artificial Intelligence ARCIC Army Capabilities Integration Center ARDEC Armament Research, Development and...Government Printing Office, 2016), 176. 3 HQDA, TRADOC Pam 525-3-1, 11-12. 3 combat team types, such as the Armored Brigade Combat Team and Stryker

  2. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  3. The treatment of the acute acromioclavicular joint dislocation with LARS artificial ligament:a preliminary report%应用LARS人工韧带治疗急性肩锁关节脱位的初步报告

    Institute of Scientific and Technical Information of China (English)

    陈爱民; 鹿楠; 叶添文; 杨鹏; 朱磊; 李菁

    2014-01-01

    Background Currently,the clinical perspectives of surgical treatment for Tossy Ⅲacromioclavicular(AC)joint dislocations are relatively identical.Due to the post-traumatic ruptures of the acromioclavicular ligament and coracoclavicular(CC)ligament which are used to maintain stability of the joint,the clavicle moves backward and upward,and the upper arm and the scapula drops downward for the gravity of the upper arm and the influence of the sternocleidomastoid muscle.Since such complications as reduction difficulties,redislocation after external fixation,pressure ulcers of the skin,and so forth are particularly prone to occur in the conservative therapy,the operative treatment is more inclined to be adopted for the Tossy Ⅲ dislocation of the AC joint.With the single repair and fixation of the CC ligament,redislocation is likely to happen after implant removal because the ruptured ligaments healed as scar tissue.Therefore,this study uses an operative method of reconstructing and augmenting the CC ligament with LARS artificial ligament for the treatment of Tossy Ⅲ AC joint dislocation,and evaluates its clinical effect.Methods From November 2006 to July 2009,8 patients with acute AC joint dislocation of Tossy Ⅲ were admitted into our hospital.Five patients were male and 3 were female,and their ages ranged from 21 to 45.Sides:3 injuries were on the left and 5 were on the right.Seven patients suffered from falling on the ground,and 1 patient was inj ured in a traffic accident.All the patients were treated with LARS artificial ligaments to reconstruct the CC ligament.Constant score and VAS score were adopted in clinical evaluation.Zanca view of the bilateral AC joint and the axillary radiograph of the affected shoulder joint were employed for imaging evaluation.All the patients were simple Tossy Ⅲ dislocation of AC joint with no trauma of other parts and skin breakdown.Regular pre-operative examinations and evaluations were carried out after admission,and LARS

  4. Parafuso de massa lateral do atlas para fixação da coluna cervical superior: resultados cirúrgicos Tornillos de masa lateral del atlas para la fijación de la columna cervical superior: resultados quirúrgicos Lateral mass screws of the atlas for upper cervical spine fixation: surgical results

    Directory of Open Access Journals (Sweden)

    Enrico Ghizoni

    2011-01-01

    Full Text Available OBJETIVO: Apresentar os resultados cirúrgicos de uma série de casos de estabilização da coluna cervical superior com o uso de parafusos de massa lateral do atlas. MÉTODOS: Avaliação retrospectiva dos resultados cirúrgicos de pacientes submetidos à estabilização da coluna cervical superior com o uso de parafusos de massa lateral do atlas. RESULTADOS: Seis pacientes foram operados durante o período de janeiro de 2009 a abril de 2010, quatro homens e duas mulheres. Não houve morbidade permanente ou morbidade nessa série de casos. A principal causa de instabilidade atlanto-axial foi trauma e houve apenas um caso de fratura patológica do odontoide por metástase de próstata. A fixação do áxis foi obtida com o uso de três diferentes técnicas de parafusos (pars, pedicular e de lâmina, com igual distribuição entre os pacientes. CONCLUSÃO: O uso de parafusos na massa lateral do atlas é uma importante técnica para se obter estabilidade e fusão na coluna cervical superior, e com o conhecimento da anatomia e da técnica cirúrgica, bons resultados podem ser atingidos.OBJETIVOS: presentar los resultados quirúrgicos de una serie de casos de estabilización con el uso de tornillos de masa lateral del atlas. MÉTODOS: evaluación retrospectiva de los resultados quirúrgicos de los pacientes sometidos a estabilización de la columna cervical superior con el uso de tornillos de masa lateral del atlas. RESULTADOS: Seis pacientes operados entre enero 2009 y abril 2010, siendo cuatro hombres y dos mujeres. No hubo mortalidad o morbilidad grave en esta serie. La principal causa de inestabilidad atlantoaxial fue traumática con apenas un caso de fractura patológica del odontoide por una metástasis de tumor de próstata. Fijación del axis fue alcanzada con el uso de tres diferentes técnicas (pars, pedicular, laminar, con dos casos cada una. Conclusión: el uso de tornillos de masa lateral en el atlas es una importante técnica para

  5. Joint awareness after total knee arthroplasty is affected by pain and quadriceps strength.

    Science.gov (United States)

    Hiyama, Y; Wada, O; Nakakita, S; Mizuno, K

    2016-06-01

    There is a growing interest in the use of patient-reported outcomes to provide a more patient-centered view on treatment. Forgetting the artificial joint can be regarded as the goal in joint arthroplasty. The goals of the study were to describe changes in joint awareness in the artificial joint after total knee arthroplasty (TKA), and to determine which factors among pain, knee range of motion (ROM), quadriceps strength, and functional ability affect joint awareness after TKA. Patients undergoing TKA demonstrate changes in joint awareness and joint awareness is associated with pain, knee ROM, quadriceps strength, and functional ability. This prospective cohort study comprised 63 individuals undergoing TKA, evaluated at 1, 6, and 12 months postoperatively. Outcomes included joint awareness assessed using the Forgotten Joint Score (FJS), pain score, knee ROM, quadriceps strength, and functional ability. Fifty-eight individuals completed all postoperative assessments. All measures except for knee extension ROM improved from 1 to 6 months. However, there were no differences in any measures from 6 to 12 months. FJS was affected most greatly by pain at 1 month and by quadriceps strength at 6 and 12 months. Patients following TKA demonstrate improvements in joint awareness and function within 6 months after surgery, but reach a plateau from 6 to 12 months. Quadriceps strength could contribute to this plateau of joint awareness. Prospective cohort study, IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Rheumatoid arthritis: Radiological changes in the cervical spine

    International Nuclear Information System (INIS)

    Al-Boukai, Ahmad A.; Al-Arfaj, Abdurahman S.

    2003-01-01

    Objective was to describe the radiographic cervical spine changes in rheumatoid arthritis patients.Forty-nine patients (37 females and 12 males ) diagnosed with rheumatoid arthritis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia between June 1998 and December 2000, were studied for their radiographic cervical spine changes . Their mean age at disease onset was 41.4 + 13.4 years (range of 18-73)and mean duration of disease was 9.1+-6.28 years (range of 2-34). Their demographic data including rheumatoid factor status was obtained. Standard conventional radiographs cervical spine were obtained to study the cervical spine changes. Cervical radiographic changes were found in 34 patients (27 females and 7 males) 10 had subluxation (7 with atlanto-axial subluxation,2 with sub-axial subluxation,and one with lateral subluxation ). No vertical impaction was seen. Erosion of odontoid process was seen in one patient .All were rheumatoid seropositive Cervical spine changes in patients with rheumatoid arthritis are common, in particular subluxation in the upper cervical spine. Our study showed somewhat lesser prevalence of these changes. These were clinically correlated with disease duration, female sex, and rheumatoid factor, but were not clinically significant. (author)

  7. Atlantoaxial subluxation. Radiography and magnetic resonance imaging correlated to myelopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Y.; Takahashi, M.; Sakamoto, Y.; Kojima, R.

    Twenty-nine patients with atlantoaxial subluxation (18 with rheumatoid arthritis, 2 due to trauma, 4 with os odontoideum, and one each with polyarteritis nodosa, rheumatic fever, Klippel-Feil syndrome, achondroplasia, and cause unknown) were evaluated using a 0.22 tesla resistive MRI unit. Cord compression was classified into four grades according to the degree on magnetic resonance imaging. There were 7 patients with no thecal sac compression (grade 0), 10 with a minimal degree of subarachnoid space compression without cord compression (grade 1), 7 with mild cord compression (grade 2), and 5 with severe cord compression or cord atrophy (grade 3). Although the severity of myelopathy showed poor correlation with the atlantodental interval on conventional radiography, high correlation was observed between MR grading and the degree of myelopathy. The high signal intensity foci were observed in 7 or 12 patients with cord compression (grades 2 and 3) on T2 weighted images. Other frequently observed findings in rheumatoid arthritis included soft tissue masses of low to intermediate signal intensity in the paraodontoid space, erosions of the odontoid processes, and atlanto-axial impaction on T1 and T2 weighted images.

  8. Atlantoaxial subluxation

    International Nuclear Information System (INIS)

    Yamashita, Y.; Takahashi, M.; Sakamoto, Y.; Kojima, R.

    1989-01-01

    Twenty-nine patients with atlantoaxial subluxation (18 with rheumatoid arthritis, 2 due to trauma, 4 with os odontoideum, and one each with polyarteritis nodosa, rheumatic fever, Klippel-Feil syndrome, achondroplasia, and cause unknown) were evaluated using a 0.22 tesla resistive MRI unit. Cord compression was classified into four grades according to the degree on magnetic resonance imaging. There were 7 patients with no thecal sac compression (grade 0), 10 with a minimal degree of subarachnoid space compression without cord compression (grade 1), 7 with mild cord compression (grade 2), and 5 with severe cord compression or cord atrophy (grade 3). Although the severity of myelopathy showed poor correlation with the atlantodental interval on conventional radiography, high correlation was observed between MR grading and the degree of myelopathy. The high signal intensity foci were observed in 7 or 12 patients with cord compression (grades 2 and 3) on T2 weighted images. Other frequently observed findings in rheumatoid arthritis included soft tissue masses of low to intermediate signal intensity in the paraodontoid space, erosions of the odontoid processes, and atlanto-axial impaction on T1 and T2 weighted images. (orig.)

  9. Artificial organs versus regenerative medicine: is it true?

    Science.gov (United States)

    Nosé, Yukihiko; Okubo, Hisashi

    2003-09-01

    . It does not matter whether these tissues are cultivated inside or outside the patient's body. Thus, we strongly believe in the need for joint development programs between artificial organ technologies and regenerative medicine technologies. In particular, the importance of using both man-made substitute organ technologies and natural tissue-derived substitute organ technologies is stressed for improved medical care in the future.

  10. Smart Collections: Can Artificial Intelligence Tools and Techniques Assist with Discovering, Evaluating and Tagging Digital Learning Resources?

    Science.gov (United States)

    Leibbrandt, Richard; Yang, Dongqiang; Pfitzner, Darius; Powers, David; Mitchell, Pru; Hayman, Sarah; Eddy, Helen

    2010-01-01

    This paper reports on a joint proof of concept project undertaken by researchers from the Flinders University Artificial Intelligence Laboratory in partnership with information managers from the Education Network Australia (edna) team at Education Services Australia to address the question of whether artificial intelligence techniques could be…

  11. Cancer risk among patients with finger and hand joint and temporo-mandibular joint prostheses in Denmark.

    Science.gov (United States)

    Fryzek, J P; Mellemkjaer, L; McLaughlin, J K; Blot, W J; Olsen, J H

    1999-05-31

    The use of artificial joint implants has risen greatly over the past years. However, few investigations of the cancer risk associated with implants have been performed. We investigated cancer risk in patients with finger and hand joint and temporo-mandibular (TMJ) joint implants. A nationwide cohort in Denmark of patients with finger and hand joint prostheses (n = 858) or TMJ implants (n = 389) was followed from January 1, 1977, to December 31, 1995, to evaluate any potential cancer risks subsequent to receiving these implants. Standardized incidence ratios (SIRs) for all cancers were 1.0 (95% CI = 0.8-1.2) for the finger and hand joint cohort and 1.1 (95% CI = 0.8-1.7) for the TMJ cohort. A significant risk for non-Hodgkin's lymphoma was found in the finger and hand joint cohort (SIR = 3.8, 95% CI = 1.5-7.8). When the finger and hand joint cohort was stratified by diagnosis of rheumatoid arthritis, the excess risk was seen only in the group with rheumatoid arthritis. This is consistent with past studies, which have found an association between rheumatoid arthritis and non-Hodgkin's lymphoma. Our results provide evidence that the cancer risk for patients with finger and hand joint prostheses and TMJ implants is similar to that for the general population.

  12. Application of computer-assisted imaging technology in human musculoskeletal joint research

    Directory of Open Access Journals (Sweden)

    Xudong Liu

    2014-01-01

    Full Text Available Computer-assisted imaging analysis technology has been widely used in the musculoskeletal joint biomechanics research in recent years. Imaging techniques can accurately reconstruct the anatomic features of the target joint and reproduce its in vivo motion characters. The data has greatly improved our understanding of normal joint function, joint injury mechanism, and surgical treatment, and can provide foundations for using reverse-engineering methods to develop biomimetic artificial joints. In this paper, we systematically reviewed the investigation of in vivo kinematics of the human knee, shoulder, lumber spine, and ankle using advanced imaging technologies, especially those using a dual fluoroscopic imaging system (DFIS. We also briefly discuss future development of imaging analysis technology in musculoskeletal joint research.

  13. Functionally graded bio-ceramic reinforced PVA hydrogel composites for knee joint artificial cartilages

    Science.gov (United States)

    Kumar, G. C. Mohan

    2018-04-01

    Research progress in materials science for bio-based materials for cartilage repair or supportive to host tissue has become a fashionable, worldwide. Few efforts in biomedical engineering has attempted in the development of newer biomaterials successfully. Bio ceramics, a class of materials been used in particulate form as a reinforcement with polymers those ensure its biocompatibility. Every artificial biomedical system has to meet the minimum in Vitro requirements for successful application. Equally the biological behavior of normal and diseased tissues is also essential to understand the artificial systems to human body.

  14. Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles

    Science.gov (United States)

    Chakarov, Dimitar; Veneva, Ivanka; Tsveov, Mihail; Venev, Pavel

    2018-03-01

    The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual "man-robot" interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles

  15. An Application of Artificial Intelligence for the Joint Estimation of Amplitude and Two-Dimensional Direction of Arrival of Far Field Sources Using 2-L-Shape Array

    Directory of Open Access Journals (Sweden)

    Fawad Zaman

    2013-01-01

    Full Text Available An easy and efficient approach, based on artificial intelligence technique, is proposed to jointly estimate the amplitude, elevation, and azimuth angles of far field sources impinging on 2-L-shape array. In these proposed artificial intelligence techniques, the metaheuristics based on genetic algorithm and simulated annealing are used as global optimizers assisted with rapid local version of pattern search for optimization of the adaptive parameters. The performance metric is employed on a fitness evaluation function depending on mean square error which is optimum and requires single snapshot to converge. The proposed approaches are easy to understand, and simple to implement; the genetic algorithm specifically hybridized with pattern search generates fairly good results. The comparison of the given schemes is carried out with 1-L-shape array, as well as, with parallel-shape array and is found to be in good agreement in terms of accuracy, convergence rate, computational complexity, and mean square error. The effectiveness and efficiency of the given schemes are examined through Monte Carlo simulations and their inclusive statistical analysis.

  16. A model-based approach to stabilizing crutch supported paraplegic standing by artificial hip joint stiffness.

    Science.gov (United States)

    van der Spek, Jaap H; Veltink, Peter H; Hermens, Hermie J; Koopman, Bart F J M; Boom, Herman B K

    2003-12-01

    The prerequisites for stable crutch supported standing were analyzed in this paper. For this purpose, a biomechanical model of crutch supported paraplegic stance was developed assuming the patient was standing with extended knees. When using crutches during stance, the crutches will put a position constraint on the shoulder, thus reducing the number of degrees of freedom. Additional hip-joint stiffness was applied to stabilize the hip joint and, therefore, to stabilize stance. The required hip-joint stiffness for changing crutch placement and hip-joint offset angle was studied under static and dynamic conditions. Modeling results indicate that, by using additional hip-joint stiffness, stable crutch supported paraplegic standing can be achieved, both under static as well as dynamic situations. The static equilibrium postures and the stability under perturbations were calculated to be dependent on crutch placement and stiffness applied. However, postures in which the hip joint was in extension (C postures) appeared to the most stable postures. Applying at least 60 N x m/rad hip-joint stiffness gave stable equilibrium postures in all cases. Choosing appropriate hip-joint offset angles, the static equilibrium postures changed to more erect postures, without causing instability or excessive arm forces to occur.

  17. Normal Development and Measurements of the Occipital Condyle-C1 Interval in Children and Young Adults.

    Science.gov (United States)

    Smith, P; Linscott, L L; Vadivelu, S; Zhang, B; Leach, J L

    2016-05-01

    Widening of the occipital condyle-C1 interval is the most specific and sensitive means of detecting atlanto-occipital dislocation. Recent studies attempting to define normal measurements of the condyle-C1 interval in children have varied substantially. This study was performed to test the null hypothesis that condyle-C1 interval morphology and joint measurements do not change as a function of age. Imaging review of subjects undergoing CT of the upper cervical spine for reasons unrelated to trauma or developmental abnormality was performed. Four equidistant measurements were obtained for each bilateral condyle-C1 interval on sagittal and coronal images. The cohort was divided into 7 age groups to calculate the mean, SD, and 95% CIs for the average condyle-C1 interval in both planes. The prevalence of a medial occipital condyle notch was calculated. Two hundred forty-eight joints were measured in 124 subjects with an age range of 2 days to 22 years. The condyle-C1 interval varies substantially by age. Average coronal measurements are larger and more variable than sagittal measurements. The medial occipital condyle notch is most prevalent from 1 to 12 years and is uncommon in older adolescents and young adults. The condyle-C1 interval increases during the first several years of life, is largest in the 2- to 4-year age range, and then decreases through late childhood and adolescence. A single threshold value to detect atlanto-occipital dissociation may not be sensitive and specific for all age groups. Application of this normative data to documented cases of atlanto-occipital injury is needed to determine clinical utility. © 2016 by American Journal of Neuroradiology.

  18. Analysis and control of a parallel lower limb based on pneumatic artificial muscles

    Directory of Open Access Journals (Sweden)

    Feilong Jiang

    2016-12-01

    Full Text Available Most robots that are actuated by antagonistic pneumatic artificial muscles are controlled by various control algorithms that cannot adequately imitate the actual muscle distribution of human limbs. Other robots in which the distribution of pneumatic artificial muscle is similar to that of human limbs can only analyze the position of the robot using perceptual data instead of rational knowledge. In order to better imitate the movement of a human limb, the article proposes a humanoid lower limb in the form of a parallel mechanism where muscle is unevenly distributed. Next, the kinematic and dynamic movements of bionic hip joint are analyzed, where the joint movement is controlled by an observer-based fuzzy adaptive control algorithm as a whole rather than each individual pneumatic artificial muscle and parameters that are optimized by a neural network. Finally, experimental results are provided to confirm the effectiveness of the proposed method. We also document the role of muscle in trajectory tracking for the piriformis and musculi obturator internus in isobaric processes.

  19. Propulsion System with Pneumatic Artificial Muscles for Powering Ankle-Foot Orthosis

    Science.gov (United States)

    Veneva, Ivanka; Vanderborght, Bram; Lefeber, Dirk; Cherelle, Pierre

    2013-12-01

    The aim of this paper is to present the design of device for control of new propulsion system with pneumatic artificial muscles. The propulsion system can be used for ankle joint articulation, for assisting and rehabilitation in cases of injured ankle-foot complex, stroke patients or elderly with functional weakness. Proposed device for control is composed by microcontroller, generator for muscles contractions and sensor system. The microcontroller receives the control signals from sensors and modulates ankle joint flex- ion and extension during human motion. The local joint control with a PID (Proportional-Integral Derivative) position feedback directly calculates desired pressure levels and dictates the necessary contractions. The main goal is to achieve an adaptation of the system and provide the necessary joint torque using position control with feedback.

  20. Nature and origin of white efflorescence on bricks, artificial stones, and joint mortars of modern houses evaluated by portable Raman spectroscopy and laboratory analyses

    Science.gov (United States)

    Morillas, Héctor; Maguregui, Maite; Trebolazabala, Josu; Madariaga, Juan Manuel

    2015-02-01

    Bricks and mortar currently constitute one of the most important building materials used in the construction of most modern facades. The deterioration of these materials is caused primarily by the impact of numerous external stressors, while poor manufacturing quality, particularly of mortars, can also contribute to this process. In this work, the non-invasive Raman spectroscopy technique was used to identify the recently formed deterioration compounds (primarily sulfates and nitrates) in bricks, artificial stones, and joint mortars from detached houses in the Bilbao metropolitan area (Basque Country, North of Spain), as well as to investigate the deterioration processes taking place in these materials. Additionally, to confirm and in some cases complement the results obtained with Raman spectroscopy, SEM-EDS and XRD measurements were also carried out.

  1. Enhancing the smoothness of joint motion induced by functional electrical stimulation using co-activation strategies

    Directory of Open Access Journals (Sweden)

    Ruppel Mirjana

    2017-09-01

    Full Text Available The motor precision of today’s neuroprosthetic devices that use artificial generation of limb motion using Functional Electrical Stimulation (FES is generally low. We investigate the adoption of natural co-activation strategies as present in antagonistic muscle pairs aiming to improve motor precision produced by FES. In a test in which artificial knee-joint movements were generated, we could improve the smoothness of FES-induced motion by 513% when applying co-activation during the phases in which torque production is switched between muscles – compared to no co-activation. We further demonstrated how the co-activation level influences the joint stiffness in a pendulum test.

  2. Clinical Significance of Articulating Facet Displacement of Lateral Atlantoaxial Joint on 3D CT in Diagnosing Atlantoaxial Subluxation

    Directory of Open Access Journals (Sweden)

    Shaoyin Duan

    2007-10-01

    Conclusion: Once AFDLAJ appears in neutral position and rotational fixation or asymmetry in rotary position, atlantoaxial subluxation can be ascertained, as well as the type and extent of subluxation, and fake subluxation due to the head's rotation or normal lateralized odontoid can be excluded. AFDLAJ is a vital direct sign in diagnosing atlantoaxial subluxation.

  3. Nature and origin of white efflorescence on bricks, artificial stones, and joint mortars of modern houses evaluated by portable Raman spectroscopy and laboratory analyses.

    Science.gov (United States)

    Morillas, Héctor; Maguregui, Maite; Trebolazabala, Josu; Madariaga, Juan Manuel

    2015-02-05

    Bricks and mortar currently constitute one of the most important building materials used in the construction of most modern facades. The deterioration of these materials is caused primarily by the impact of numerous external stressors, while poor manufacturing quality, particularly of mortars, can also contribute to this process. In this work, the non-invasive Raman spectroscopy technique was used to identify the recently formed deterioration compounds (primarily sulfates and nitrates) in bricks, artificial stones, and joint mortars from detached houses in the Bilbao metropolitan area (Basque Country, North of Spain), as well as to investigate the deterioration processes taking place in these materials. Additionally, to confirm and in some cases complement the results obtained with Raman spectroscopy, SEM-EDS and XRD measurements were also carried out. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242

    Directory of Open Access Journals (Sweden)

    Ahmed R. J. Almusawi

    2016-01-01

    Full Text Available This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot’s joint angles.

  5. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242)

    Science.gov (United States)

    Dülger, L. Canan; Kapucu, Sadettin

    2016-01-01

    This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot's joint angles. PMID:27610129

  6. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242).

    Science.gov (United States)

    Almusawi, Ahmed R J; Dülger, L Canan; Kapucu, Sadettin

    2016-01-01

    This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot's joint angles.

  7. Intelligent screening of electrofusion-polyethylene joints based on a thermal NDT method

    Science.gov (United States)

    Doaei, Marjan; Tavallali, M. Sadegh

    2018-05-01

    The combinations of infrared thermal images and artificial intelligence methods have opened new avenues for pushing the boundaries of available testing methods. Hence, in the current study, a novel thermal non-destructive testing method for polyethylene electrofusion joints was combined with k-means clustering algorithms as an intelligent screening tool. The experiments focused on ovality of pipes in the coupler, as well as misalignment of pipes-couplers in 25 mm diameter joints. The temperature responses of each joint to an internal heat pulse were recorded by an IR thermal camera, and further processed to identify the faulty joints. The results represented clustering accuracy of 92%, as well as more than 90% abnormality detection capabilities.

  8. Full Scale 3D Preoperative Planning System of the Ankle Joint Replacement Surgery with Multimedia System

    Directory of Open Access Journals (Sweden)

    Shuh-Ping Sun

    2014-05-01

    Full Text Available This study is intended to develop a computer-aided pre-surgical planning and simulating system in a multimedia environment for ankle joint replacement surgery. This system uses full-scale 3D reverse engineering techniques in design and development of the pre-surgical planning modules for ankle joint replacement surgery. This planning system not only develops the real-scale 3D image of the artificial ankle joint but also provides a detailed interior measurement of the ankle joint from various cutting planes. In this study, we apply the multimedia user interface to integrate different software functions into a surgical planning system with integrated functions. The functions include 3D model image acquisition, cutting, horizontal shifting and rotation of related bones (tibia and talus of the ankle joint in the predetermined time. For related bones of the ankle joint, it can also be used to design artificial ankle joints for adults in Taiwan. Those planning procedures can be recorded in this system for further research and investigation. Furthermore, since this system is a multimedia user interface, surgeons can use this system to plan and find a better and more efficient surgical approach before surgery. A database is available for this system to update and expand, which can provide different users with clinical cases as per their experience and learning.

  9. Artificial learners adopting normative conventions from human teachers

    Directory of Open Access Journals (Sweden)

    Cederborg Thomas

    2017-11-01

    Full Text Available This survey provides an overview of implemented systems, theoretical work, as well as studies of biological systems relevant to the design of artificial learners trying to figure out what a human teacher would like them to do. Implementations of artificial learners are covered, with a focus on experiments trying to find better interpretations of human behavior, as well as algorithms that autonomously improve a model of the teacher. A distinction is made between learners trying to interpret teacher behavior in order to learn what the teacher would like the learner to do on the one hand, and learners whose explicit or implicit goal is to get something from the teacher on the other hand (for example rewards, or knowledge about how the world works. The survey covers the former type of systems. Human teachers are covered, focusing on studies that say something concrete about how one should interpret the behavior of a human teacher that is interacting with an artificial learner. Certain types of biological learners are interesting as inspiration for the types of artificial systems we are concerned with. The survey focus on studies of biological learners adopting normative conventions, as well as joint intentionality team efforts.

  10. Craniocervical junction abnormalities with atlantoaxial subluxation caused by ventral subluxation of C2 in a dog

    Directory of Open Access Journals (Sweden)

    Harumichi Itoh

    2017-03-01

    Full Text Available Craniocervical junction abnormalities with atlantoaxial subluxation caused by ventral subluxation of C2 were diagnosed in a 6-month-old female Pomeranian with tetraplegia as a clinical sign. Lateral survey radiography of the neck with flexion revealed atlantoaxial subluxation with ventral subluxation of C2. Computed tomography revealed absence of dens and atlanto-occipital overlapping. Magnetic resonance imaging showed compression of the spinal cord and indentation of caudal cerebellum. The diagnosis was Chiari-like malformation, atlantoaxial subluxation with ventral displacement of C2, atlanto-occipital overlapping, and syringomyelia. The dog underwent foramen magnum decompression, dorsal laminectomy of C1, and ventral fixation of the atlantoaxial joint. Soon after the operation, voluntary movements of the legs were recovered. Finally, the dog could stand and walk without assistance. The dog had complicated malformations at the craniocervical junction but foramen magnum decompression and dorsal laminectomy for Chiari-like malformation, and ventral fixation for atlantoaxial subluxation resulted in an excellent clinical outcome.

  11. Development of an Underactuated 2-DOF Wrist Joint using McKibben PAMs

    Science.gov (United States)

    Rajagopal, S. P.; Jain, S.; Ramasubramanian, S. N.; Johnson, B. V.; Dwivedy, S. K.

    2014-10-01

    In this work, model of an underactuated 2-DOF wrist joint with pneumatically actuated muscles is proposed. For the joint, McKibben-type artificial muscles are used in parallel configuration for the actuation. For each Degree of Freedom (DOF) one agonist-antagonist pair arrangement is usually used with a pulley mechanism. A mathematical model of wrist joint is derived using conventional forward kinematic analysis. The static model relating pressure in the muscle with the orientation of the wrist joint is obtained by combining the experimental data and mathematical model. Regulation of pressure can be achieved by pulse width modulation control of on/off solenoid valves. A set of free vibration experiments are done for the dynamic identification of the muscle characteristics.

  12. Incorporating ligament laxity in a finite element model for the upper cervical spine.

    Science.gov (United States)

    Lasswell, Timothy L; Cronin, Duane S; Medley, John B; Rasoulinejad, Parham

    2017-11-01

    Predicting physiological range of motion (ROM) using a finite element (FE) model of the upper cervical spine requires the incorporation of ligament laxity. The effect of ligament laxity can be observed only on a macro level of joint motion and is lost once ligaments have been dissected and preconditioned for experimental testing. As a result, although ligament laxity values are recognized to exist, specific values are not directly available in the literature for use in FE models. The purpose of the current study is to propose an optimization process that can be used to determine a set of ligament laxity values for upper cervical spine FE models. Furthermore, an FE model that includes ligament laxity is applied, and the resulting ROM values are compared with experimental data for physiological ROM, as well as experimental data for the increase in ROM when a Type II odontoid fracture is introduced. The upper cervical spine FE model was adapted from a 50th percentile male full-body model developed with the Global Human Body Models Consortium (GHBMC). FE modeling was performed in LS-DYNA and LS-OPT (Livermore Software Technology Group) was used for ligament laxity optimization. Ordinate-based curve matching was used to minimize the mean squared error (MSE) between computed load-rotation curves and experimental load-rotation curves under flexion, extension, and axial rotation with pure moment loads from 0 to 3.5 Nm. Lateral bending was excluded from the optimization because the upper cervical spine was considered to be primarily responsible for flexion, extension, and axial rotation. Based on recommendations from the literature, four varying inputs representing laxity in select ligaments were optimized to minimize the MSE. Funding was provided by the Natural Sciences and Engineering Research Council of Canada as well as GHMBC. The present study was funded by the Natural Sciences and Engineering Research Council of Canada to support the work of one graduate student

  13. An artificial neural network approach and sensitivity analysis in predicting skeletal muscle forces.

    Science.gov (United States)

    Vilimek, Miloslav

    2014-01-01

    This paper presents the use of an artificial neural network (NN) approach for predicting the muscle forces around the elbow joint. The main goal was to create an artificial NN which could predict the musculotendon forces for any general muscle without significant errors. The input parameters for the network were morphological and anatomical musculotendon parameters, plus an activation level experimentally measured during a flexion/extension movement in the elbow. The muscle forces calculated by the 'Virtual Muscle System' provide the output. The cross-correlation coefficient expressing the ability of an artificial NN to predict the "true" force was in the range 0.97-0.98. A sensitivity analysis was used to eliminate the less sensitive inputs, and the final number of inputs for a sufficient prediction was nine. A variant of an artificial NN for a single specific muscle was also studied. The artificial NN for one specific muscle gives better results than a network for general muscles. This method is a good alternative to other approaches to calculation of muscle force.

  14. The influence of artificially increased hip and trunk stiffness on balance control in man.

    NARCIS (Netherlands)

    Grüneberg, C.; Bloem, B.R.; Honegger, F.; Allum, J.H.J.

    2004-01-01

    Lightweight corsets were used to produce mid-body stiffening, rendering the hip and trunk joints practically inflexible. To examine the effect of this artificially increased stiffness on balance control, we perturbed the upright stance of young subjects (20-34 years of age) while they wore one of

  15. Artificial Consciousness or Artificial Intelligence

    OpenAIRE

    Spanache Florin

    2017-01-01

    Artificial intelligence is a tool designed by people for the gratification of their own creative ego, so we can not confuse conscience with intelligence and not even intelligence in its human representation with conscience. They are all different concepts and they have different uses. Philosophically, there are differences between autonomous people and automatic artificial intelligence. This is the difference between intelligence and artificial intelligence, autonomous versus a...

  16. Avaliação tomográfica de parâmetros morfométricos do processo odontoide relacionados à fixação interna com parafusos Evaluación tomográfica de parámetros morfométricos del proceso odontoides relacionados con la fijación interna con tornillos Tomographic evaluation of odontoid parameters related to its internal fixation

    Directory of Open Access Journals (Sweden)

    Murilo Tavares Daher

    2010-09-01

    Full Text Available OBJETIVOS: avaliar, por meio da tomografia computadorizada, os parâmetros morfométricos do processo odontoide relacionados com a sua fixação interna. MÉTODOS: cinquenta e cinco exames de tomografia computadorizada (TC da coluna cervical que permitissem o estudo do áxis foram utilizados para o estudo. Destes, 24 (47% pertenciam a pacientes do sexo masculino e 31 do sexo feminino. A média de idade foi de 42,05 anos (± 15,82. Foram excluídos os casos com diagnóstico de tumores, infecções, sequelas de fratura, artrose muito avançada ou malformações congênitas. Nenhum dos exames tinha como indicação problemas relacionados à coluna cervical alta. Foram avaliados os seguintes parâmetros: 1 - comprimento estimado do implante (CEI, 2 - angulação do parafuso (aP, 3 - diâmetro transverso mínimo (DTmín e 4 - diâmetro anteroposterior mínimo (DAPmín. Foi utilizado o teste t de Student para comparar os resultados entre o grupo de pacientes do sexo masculino e do feminino. RESULTADOS: o valor médio do CEI foi de 37,95 mm ± 3,44 para a população geral do estudo. O valor médio da angulação do parafuso (aP foi de 60,91º ± 4,06. O diâmetro transverso mínimo (DTmín foi de 9,05 mm ± 0,88 e o diâmetro antero-posterior mínimo DAPmín foi de 10,35 mm ±1,04. Os valores do CEI e do DAPmín na população masculina foram significativamente maiores do que aqueles encontrados na feminina, enquanto os outros parâmetros não apresentaram diferenças entre os dois sexos na população estudada. Dos 55 pacientes, 39% apresentaram DTmín OBJETIVOS: evaluar, por medio de la tomografía computarizada, los parámetros morfométricos del proceso odontoides relacionados con su fijación interna. MÉTODOS: para el estudio, fueron utilizados 55 exámenes de tomografía computarizada (TC de la columna cervical que permitieran el estudio del axis. De éstos, 24 (47% pertenecían a pacientes del sexo masculino. El promedio de edad fue de 42.05 a

  17. Influences of post weld heat treatment on tensile strength and microstructure characteristics of friction stir welded butt joints of AA2014-T6 aluminum alloy

    Science.gov (United States)

    Rajendran, C.; Srinivasan, K.; Balasubramanian, V.; Balaji, H.; Selvaraj, P.

    2016-08-01

    Friction stir welded (FSWed) joints of aluminum alloys exhibited a hardness drop in both the advancing side (AS) and retreating side (RS) of the thermo-mechanically affected zone (TMAZ) due to the thermal cycle involved in the FSW process. In this investigation, an attempt has been made to overcome this problem by post weld heat treatment (PWHT) methods. FSW butt (FSWB) joints of Al-Cu (AA2014-T6) alloy were PWHT by two methods such as simple artificial aging (AA) and solution treatment followed by artificial aging (STA). Of these two treatments, STA was found to be more beneficial than the simple aging treatment to improve the tensile properties of the FSW joints of AA2014 aluminum alloy.

  18. Effect of Mg and Cu on mechanical properties of high-strength welded joints of aluminum alloys obtained by laser welding

    Science.gov (United States)

    Annin, B. D.; Fomin, V. M.; Karpov, E. V.; Malikov, A. G.; Orishich, A. M.

    2017-09-01

    Results of experimental investigations of welded joints of high-strength aluminum-lithium alloys of the Al-Cu-Li and Al-Mg-Li systems are reported. The welded joints are obtained by means of laser welding and are subjected to various types of processing for obtaining high-strength welded joints. A microstructural analysis is performed. The phase composition and mechanical properties of the welded joints before and after heat treatment are studied. It is found that combined heat treatment of the welded joint (annealing, quenching, and artificial ageing) increases the joint strength, but appreciably decreases the alloy strength outside the region thermally affected by the welding process.

  19. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kocasarac, Husniye Demirturk [Dept. of Comprehensive Dentistry, The University of Texas Health Science Center, San Antonio (United States); Celenk, Peruze [Dept. of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun (Turkmenistan)

    2017-06-15

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.

  20. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    International Nuclear Information System (INIS)

    Kocasarac, Husniye Demirturk; Celenk, Peruze

    2017-01-01

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images

  1. ROBERT autonomous navigation robot with artificial vision

    International Nuclear Information System (INIS)

    Cipollini, A.; Meo, G.B.; Nanni, V.; Rossi, L.; Taraglio, S.; Ferjancic, C.

    1993-01-01

    This work, a joint research between ENEA (the Italian National Agency for Energy, New Technologies and the Environment) and DIGlTAL, presents the layout of the ROBERT project, ROBot with Environmental Recognizing Tools, under development in ENEA laboratories. This project aims at the development of an autonomous mobile vehicle able to navigate in a known indoor environment through the use of artificial vision. The general architecture of the robot is shown together with the data and control flow among the various subsystems. Also the inner structure of the latter complete with the functionalities are given in detail

  2. Influence of artificial shock absorbers on human gait.

    Science.gov (United States)

    Voloshin, A; Wosk, J

    1981-10-01

    The effect of artificial shock absorbers on the human gait and the technique for its quantitative evaluation have been studied. The results obtained have shown that viscoelastic inserts reduced the amplitude of the incoming shock waves bearing upon the musculoskeletal system as a result of the heel strike, by 42 percent (mean value). Conservative treatment, using such inserts for patients with different clinical symptoms of degenerative joint diseases, has shown excellent results. Seventy-eight percent of the clinical symptoms disappeared, while satisfactory improvement was reported in 17 percent of the subjects.

  3. Microstructure of friction stir welded joints of 2017A aluminium alloy sheets.

    Science.gov (United States)

    Mroczka, K; Dutkiewicz, J; Pietras, A

    2010-03-01

    The present study examines a friction stir welded 2017A aluminium alloy. Transmission electron microscope investigations of the weld nugget revealed the average grain size of 5 microm, moderate density of dislocations as well as the presence of nanometric precipitates located mostly in grains interiors. Scanning electron microscope observations of fractures showed the presence of ductile fracture in the region of the weld nugget with brittle precipitates in the lower part. The microhardness analysis performed on the cross-section of the joints showed fairly small changes; however, after the artificial ageing process an increase in hardness was observed. The change of the joint hardness subject to the ageing process indicates partial supersaturation in the material during friction stir welding and higher precipitation hardening of the joint.

  4. Patterns of radiographic damage to cervical spine in polyarticular juvenile idiopathic arthritis patients presenting to tertiary care hospital in pakistan

    International Nuclear Information System (INIS)

    Khyzer, E.; Aftab, T.

    2015-01-01

    Objective: To see the radiographic cervical spine damage in polyarticular juvenile idiopathic arthritis (PJIA) coming to a tertiary care hospital in Islamabad, Pakistan. Study Design: Cross-sectional descriptive study. Place and Duration of Study: The study was conducted in department of Rheumatology at Pakistan Institute of Medical Sciences from Jun 2013 to Dec 2013. Subjects and Methods: A total of 50 patients of PJIA coming to Rheumatology Outpatient Department were recruited in the study after informed consent. Radiographs of cervical spine were performed for each patient in antero-posterior, lateral with flexion and extension and open-mouth views. Radiographs were reviewed for the following eatures: loss of cervical lordosis, odontoid process erosion, anterior atlantoaxial subluxation, C1-C2 arthritis, atlantoaxial impaction, inflammation of disc, apophyseal joint arthritis, anterior ankylosis, apophyseal joint ankylosis, anterior and posterior subaxial subluxation and growth disturbances. Data was analysed using SPSS version 18. Results: Out of the total 50 patients, 28 (56%) were females while 22 (44%) were males. The mean duration of pJIA was 5.54 +- 3.28 years. Radiological cervical spine involvement was seen in 52% patients. The most common structural lesions were anterior atlantoaxial subluxation (30%), C1-C2 arthritis (22%) erosion of the odontoid process (18%), and apophyseal joint arthritis (16%). Loss of cervical lordosis was found in 7(14%) patients. There was no growth disturbances observed in vertebra. Conclusion: Cervical spine involvement is common in patients of PJIA. It is mostly asymptomatic, so routine cervical spine radiographs in all patients suffering from PJIA is recommended. (author)

  5. Natural - synthetic - artificial!

    DEFF Research Database (Denmark)

    Nielsen, Peter E

    2010-01-01

    The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life.......The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life....

  6. SYMPTOM COMPLEX OF CHRONICAL ATLANTOAXIAL SUBLUXATION IN PAEDIATRIC PATIENTS

    Directory of Open Access Journals (Sweden)

    A. G. Baindurashvili

    2012-01-01

    Full Text Available The objective of this study is to determine the complex of symptoms, including both orthopedic and neurological changes that occur against the backdrop of long-existing disturbances of the atlanto-axial joint. The authors conducted in-depth analysis of the orthopedic and neurological examination of 58 children aged between 10 and 17 years with first diagnosed disturbances of relationship between C1 and C2 vertebrae. Complexes of symptoms are identified from the combination of clinical data obtained with in-depth orthopedic and neurological examinations that are pathognomonic for lateral and posterior atlanto-axial chronic subluxation. Rotational subluxation of C1-C2 vertebral-motor segment was associated with concomitant neurological disorders and additionally with the no gross structural deformity of the spine and the disturbed foot support function in all cases. Using of the study findings will allow to make an adequate diagnosis and to determine the correct choice of additional diagnostic and therapeutic methods for this category of patients on the stage of conventional examination of the patient in clinical practice.

  7. Autonomous Quality Control of Joint Orientation Measured with Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Karina Lebel

    2016-07-01

    Full Text Available Clinical mobility assessment is traditionally performed in laboratories using complex and expensive equipment. The low accessibility to such equipment, combined with the emerging trend to assess mobility in a free-living environment, creates a need for body-worn sensors (e.g., inertial measurement units—IMUs that are capable of measuring the complexity in motor performance using meaningful measurements, such as joint orientation. However, accuracy of joint orientation estimates using IMUs may be affected by environment, the joint tracked, type of motion performed and velocity. This study investigates a quality control (QC process to assess the quality of orientation data based on features extracted from the raw inertial sensors’ signals. Joint orientation (trunk, hip, knee, ankle of twenty participants was acquired by an optical motion capture system and IMUs during a variety of tasks (sit, sit-to-stand transition, walking, turning performed under varying conditions (speed, environment. An artificial neural network was used to classify good and bad sequences of joint orientation with a sensitivity and a specificity above 83%. This study confirms the possibility to perform QC on IMU joint orientation data based on raw signal features. This innovative QC approach may be of particular interest in a big data context, such as for remote-monitoring of patients’ mobility.

  8. Acousto-ultrasonic evaluation of adhesively bonded CFRP-aluminum joints

    International Nuclear Information System (INIS)

    Lee, Seung Hwan; Kwon, Oh Yang

    1997-01-01

    Correlation between the amount of artificial defects in bonded region and the acousto-ultrasonic parameters(AUPs) including signal amplitude and then the static strength of adhesively bonded joints of carbon fiber reinforced plastic(CFRP) laminates and Al6061 plates has been investigated. The effect of the frequency content and the bandwidth of input signals were studied using 200 kHz, 650 kHz, 1 MHz, 2 MHz pulses and 1 MHz tone-burst signals. With increasing fraction of defects, the signal amplitude and AUP1 were decreased whereas AUP2 was increased. This result has been attributed to the energy transfer characteristics of bonded joints with delamination-type defects and the change of spectral content due to the defects. Considering the nature of high attenuation, a pulse signal with major frequency content at the third harmonic of thickness mode resonance, 650 kHz for the dimension of specimens used in this study, has been found optimal for acousto-ultrasonic testing of CFRP-aluminum joints.

  9. Visual detection of defects in solder joints

    Science.gov (United States)

    Blaignan, V. B.; Bourbakis, Nikolaos G.; Moghaddamzadeh, Ali; Yfantis, Evangelos A.

    1995-03-01

    The automatic, real-time visual acquisition and inspection of VLSI boards requires the use of machine vision and artificial intelligence methodologies in a new `frame' for the achievement of better results regarding efficiency, products quality and automated service. In this paper the visual detection and classification of different types of defects on solder joints in PC boards is presented by combining several image processing methods, such as smoothing, segmentation, edge detection, contour extraction and shape analysis. The results of this paper are based on simulated solder defects and a real one.

  10. Artificial intelligence

    CERN Document Server

    Hunt, Earl B

    1975-01-01

    Artificial Intelligence provides information pertinent to the fundamental aspects of artificial intelligence. This book presents the basic mathematical and computational approaches to problems in the artificial intelligence field.Organized into four parts encompassing 16 chapters, this book begins with an overview of the various fields of artificial intelligence. This text then attempts to connect artificial intelligence problems to some of the notions of computability and abstract computing devices. Other chapters consider the general notion of computability, with focus on the interaction bet

  11. Artificial Consciousness or Artificial Intelligence

    Directory of Open Access Journals (Sweden)

    Spanache Florin

    2017-05-01

    Full Text Available Artificial intelligence is a tool designed by people for the gratification of their own creative ego, so we can not confuse conscience with intelligence and not even intelligence in its human representation with conscience. They are all different concepts and they have different uses. Philosophically, there are differences between autonomous people and automatic artificial intelligence. This is the difference between intelligence and artificial intelligence, autonomous versus automatic. But conscience is above these differences because it is neither conditioned by the self-preservation of autonomy, because a conscience is something that you use to help your neighbor, nor automatic, because one’s conscience is tested by situations which are not similar or subject to routine. So, artificial intelligence is only in science-fiction literature similar to an autonomous conscience-endowed being. In real life, religion with its notions of redemption, sin, expiation, confession and communion will not have any meaning for a machine which cannot make a mistake on its own.

  12. Economic feasibility of artificial islands for cluster-siting of offshore energy facilities

    International Nuclear Information System (INIS)

    Baram, M.S.; Spencer, J.; Munson, J.S.

    1977-04-01

    The study presents a general first-order cost feasibility analysis of the artificial island concept and its usefulness for the offshore siting of multiple energy facilities. The results of the study include a recommended method of cost-feasibility assessment; the collection and organization of the most useful information presently available; and a series of conclusions on feasibility for generic comparison purposes. These conclusions can be summarized as follows: (1) artificial islands to the outer bound of the continental shelf are technologically feasible; (2) offshore nuclear power plants appear to be competitive with onshore plants from a cost standpoint; (3) offshore deepwater ports appear to be more economical than proposed onshore deepwater ports, existing facilities or facilities presently under construction; (4) offshore oil refineries, except under special circumstantces, will probably be more costly than onshore counterparts; (5) the cluster-siting of facilities on an artificial island has definite cost-effectiveness potential; (6) a joint public-private financial venture with a strong federal agency lead role appears essential for the multi-facility island concept to be realized; and (7) artificial island siting of energy complexes appears to be a concept worth pursuing in terms of further site and facility-specific research, and possibly in terms of a demonstration project

  13. Third International Symposium on Artificial Intelligence, Robotics, and Automation for Space 1994

    Science.gov (United States)

    1994-01-01

    The Third International Symposium on Artificial Intelligence, Robotics, and Automation for Space (i-SAIRAS 94), held October 18-20, 1994, in Pasadena, California, was jointly sponsored by NASA, ESA, and Japan's National Space Development Agency, and was hosted by the Jet Propulsion Laboratory (JPL) of the California Institute of Technology. i-SAIRAS 94 featured presentations covering a variety of technical and programmatic topics, ranging from underlying basic technology to specific applications of artificial intelligence and robotics to space missions. i-SAIRAS 94 featured a special workshop on planning and scheduling and provided scientists, engineers, and managers with the opportunity to exchange theoretical ideas, practical results, and program plans in such areas as space mission control, space vehicle processing, data analysis, autonomous spacecraft, space robots and rovers, satellite servicing, and intelligent instruments.

  14. The structure and functioning of Dynastab DK - K fixator (knee joint) and its usefullness in clinical use.

    Science.gov (United States)

    Deszczyński, J; Karpiński, J; Deszczyńska, H

    1999-12-30

    The autor describes following stages of research on external fixator Dynastab DK - K (knee joint) with in - built artificial joint enabling physiological range of movement of the knee and the use of the device in functional treatment of articular fractures of the knee. The final clinical prototype of the device was developed according to the results of the experiments with anatomical preparations of knee joints in which the trajectory of the physiological movement of the knee was stated. These observations were used to construct mechanical joint with the range of movement adequate to this of the healthy knee. The positive and negative aspects in DK - K fixator are also described. The fixator was appled in 6 difficult cases of articular fractures of knee with good results.

  15. Physical activity in the elderly who underwent joint replacement surgery in the course of rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Agnieszka Prusinowska

    2016-07-01

    Full Text Available According to the forecasts of the Central Statistical Office of Poland, in 2030 people at the age of 65 and older will account for 23.8%, i.e. their number will amount to approx. 8.5 m people. Geriatric rheumatic patients more often decide to undergo surgical joint replacement. According to the National Health Fund, the number of joint replacement services provided in 2014 increased by 93%, as compared to 2005. Improving the physical performance of this constantly expanding group of patients requires taking into account many factors to raise their functional status, reduce the risk of falling, teach rules of proper functioning with an artificial joint and encourage unassisted physical activity. Restoring fitness and independence is a difficult but necessary task due to an increasing number of seniors with replaced joint.

  16. Human Activity Recognition in Real-Times Environments using Skeleton Joints

    Directory of Open Access Journals (Sweden)

    Ajay Kumar

    2016-06-01

    Full Text Available In this research work, we proposed a most effective noble approach for Human activity recognition in real-time environments. We recognize several distinct dynamic human activity actions using kinect. A 3D skeleton data is processed from real-time video gesture to sequence of frames and getter skeleton joints (Energy Joints, orientation, rotations of joint angles from selected setof frames. We are using joint angle and orientations, rotations information from Kinect therefore less computation required. However, after extracting the set of frames we implemented several classification techniques Principal Component Analysis (PCA with several distance based classifiers and Artificial Neural Network (ANN respectively with some variants for classify our all different gesture models. However, we conclude that use very less number of frame (10-15% for train our system efficiently from the entire set of gesture frames. Moreover, after successfully completion of our classification methods we clinch an excellent overall accuracy 94%, 96% and 98% respectively. We finally observe that our proposed system is more useful than comparing to other existing system, therefore our model is best suitable for real-time application such as in video games for player action/gesture recognition.

  17. Artificial defects detection and location during welding

    International Nuclear Information System (INIS)

    Asty, M.

    1978-01-01

    Welding control by acoustic emission allows defects detection as soon as they are created. Acoustic testing saves time and gives better quality assurance in the case of multiple pass welding of plates. A welded joint was performed on A533B steel plates 250 mm thick by submerged arc welding. Artificial defects were implanted to determine significative parameters of acoustic reception. In operating conditions a significant acoustic activity takes place only during welding as shown by preliminary tests. At the same time an important noise is created by the arc, scories cooling and metal solidification and cooling. These problems are solved by an original processing in time-space detecting and locating defects with a good approximation [fr

  18. Liquid crystals in biotribology synovial joint treatment

    CERN Document Server

    Ermakov, Sergey; Eismont, Oleg; Nikolaev, Vladimir

    2016-01-01

    This book summarizes the theoretical and experimental studies confirming the concept of the liquid-crystalline nature of boundary lubrication in synovial joints. It is shown that cholesteric liquid crystals in the synovial liquid play a significant role in the mechanism of intra-articular friction reduction. The results of structural, rheological and tribological research of the creation of artificial synovial liquids - containing cholesteric liquid crystals in natural synovial liquids - are described. These liquid crystals reproduce the lubrication properties of natural synovia and provide a high chondroprotective efficiency. They were tested in osteoarthritis models and in clinical practice.

  19. Fatigue crack growth in welded joints in seawater

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, S.B.

    1988-01-01

    A pipe-to-plate specimen has been developed to study the influence of seawater on the fatigue behaviour of welded tubular joints. DC potential drop techniques have been used to detect fatigue crack initiation, and to monitor the subsequent growth of fatigue cracks. Results for three specimens, tested in air are compared with similar data for tubular and T-plate joints. These comparisons indicate that the pipe/plate is a reasonable model of a tubular joint. Testing was performed on a further six specimens in artificial seawater; two each with free corrosion, optimum cathodic protection, and cathodic overprotection. Fatigue life reduction factors compared with corresponding tests in air were 1.8 and 2.8 for free corrosion, 1.7 and 1.1 with cathodic protection, and 4.2 and 3.3 with cathodic over-protection. These fatigue life reduction factors were comparable to results on T-plate specimens, and were strongly dependent on crack shape development. Linear elastic fracture mechanics techniques appear suitable for the calculation of fatigue crack propagation life. Three approximate solution techniques for crack tip stress intensity factors show reasonable agreement with experimentally derived values. It is recommended that forcing functions be used to model crack aspect ratio development in welded joints. Such forcing functions are influenced by the initial stress distribution and the environment. 207 refs., 192 figs., 22 tabs.

  20. Artificial skin and patient simulator comprising the artificial skin

    NARCIS (Netherlands)

    2011-01-01

    The invention relates to an artificial skin (10, 12, 14), and relates to a patient simulator (100) comprising the artificial skin. The artificial skin is a layered structure comprising a translucent cover layer (20) configured for imitating human or animal skin, and comprising a light emitting layer

  1. Validation study of the Forgotten Joint Score-12 as a universal patient-reported outcome measure.

    Science.gov (United States)

    Matsumoto, Mikio; Baba, Tomonori; Homma, Yasuhiro; Kobayashi, Hideo; Ochi, Hironori; Yuasa, Takahito; Behrend, Henrik; Kaneko, Kazuo

    2015-10-01

    The Forgotten Joint Score-12 (FJS-12) is for patients to forget their artificial joint and is reportedly a useful patient-reported outcome tool for artificial joints. The purpose of this study was to determine whether the FJS-12 is as useful as the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) or the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ) in Japan. All patients who visited our hospital's hip joint specialists following unilateral THA from August 2013 to July 2014 were evaluated. Medical staff members other than physicians administered three questionnaires. Items evaluated were (1) the reliability of the FJS-12 and (2) correlations between the FJS-12 and the total and subscale scores of the WOMAC or JHEQ. Of 130 patients, 22 were excluded. Cronbach's α coefficient was 0.97 for the FJS-12. The FJS-12 showed a significantly lower score than the WOMAC or JHEQ (p < 0.01). The FJS-12 was moderately correlated with the total WOMAC score (r = 0.522) and its subscale scores for "stiffness" (r = 0.401) and "function" (r = 0.539) and was weakly correlated with the score for "pain" (r = 0.289). The FJS-12 was favorably correlated with the total JHEQ score (r = 0.686) and its subscale scores (r = 0.530-0.643). The FJS-12 was correlated with and showed reliability similar to that of the JHEQ and WOMAC. The FJS-12, which is not affected by culture or lifestyle, may be useful in Japan.

  2. Effect of carbon ion implantation on the tribology of metal-on-metal bearings for artificial joints.

    Science.gov (United States)

    Koseki, Hironobu; Tomita, Masato; Yonekura, Akihiko; Higuchi, Takashi; Sunagawa, Sinya; Baba, Koumei; Osaki, Makoto

    2017-01-01

    Metal-on-metal (MoM) bearings have become popular due to a major advantage over metal-on-polymer bearings for total hip arthroplasty in that the larger femoral head and hydrodynamic lubrication of the former reduce the rate of wear. However, concerns remain regarding adverse reactions to metal debris including metallosis caused by metal wear generated at the taper-head interface and another modular junction. Our group has hypothesized that carbon ion implantation (CII) may improve metal wear properties. The purpose of this study was to investigate the wear properties and friction coefficients of CII surfaces with an aim to ultimately apply these surfaces to MoM bearings in artificial joints. CII was applied to cobalt-chromium-molybdenum (Co-Cr-Mo) alloy substrates by plasma source ion implantation. The substrates were characterized using scanning electron microscopy and a 3D measuring laser microscope. Sliding contact tests were performed with a simple geometry pin-on-plate wear tester at a load of 2.5 N, a calculated contact pressure of 38.5 MPa (max: 57.8 MPa), a reciprocating velocity of 30 mm/s, a stroke length of 60 mm, and a reciprocating cycle count of 172,800 cycles. The surfaces of the CII substrates were generally featureless with a smooth surface topography at the same level as untreated Co-Cr-Mo alloy. Compared to the untreated Co-Cr-Mo alloy, the CII-treated bearings had lower friction coefficients, higher resistance to catastrophic damage, and prevented the adhesion of wear debris. The results of this study suggest that the CII surface stabilizes the wear status due to the low friction coefficient and low infiltration of partner materials, and these properties also prevent the adhesion of wear debris and inhibit excessive wear. Carbon is considered to be biologically inert; therefore, CII is anticipated to be applicable to the bearing surfaces of MoM prostheses.

  3. Artificial Intelligence.

    Science.gov (United States)

    Information Technology Quarterly, 1985

    1985-01-01

    This issue of "Information Technology Quarterly" is devoted to the theme of "Artificial Intelligence." It contains two major articles: (1) Artificial Intelligence and Law" (D. Peter O'Neill and George D. Wood); (2) "Artificial Intelligence: A Long and Winding Road" (John J. Simon, Jr.). In addition, it contains two sidebars: (1) "Calculating and…

  4. Artificial organs: recent progress in artificial hearing and vision.

    Science.gov (United States)

    Ifukube, Tohru

    2009-01-01

    Artificial sensory organs are a prosthetic means of sending visual or auditory information to the brain by electrical stimulation of the optic or auditory nerves to assist visually impaired or hearing-impaired people. However, clinical application of artificial sensory organs, except for cochlear implants, is still a trial-and-error process. This is because how and where the information transmitted to the brain is processed is still unknown, and also because changes in brain function (plasticity) remain unknown, even though brain plasticity plays an important role in meaningful interpretation of new sensory stimuli. This article discusses some basic unresolved issues and potential solutions in the development of artificial sensory organs such as cochlear implants, brainstem implants, artificial vision, and artificial retinas.

  5. Ethanol production from steam exploded rapeseed straw and the process simulation using artificial neural networks

    DEFF Research Database (Denmark)

    Talebnia, Farid; Mighani, Moein; Rahimnejad, Mostafa

    2015-01-01

    and 67% of maximum theoretical value. Next, data of the experimental runs were exploited for modeling the processes by artificial neural networks (ANNs) and performance of the developed models was evaluated. The ANN-based models showed a great potential for time-course prediction of the studied processes....... Efficiency of the joint network for simulating the whole process was also determined and promising results were obtained....

  6. Comprehensive joint feedback control for standing by functional neuromuscular stimulation-a simulation study.

    Science.gov (United States)

    Nataraj, Raviraj; Audu, Musa L; Kirsch, Robert F; Triolo, Ronald J

    2010-12-01

    Previous investigations of feedback control of standing after spinal cord injury (SCI) using functional neuromuscular stimulation (FNS) have primarily targeted individual joints. This study assesses the potential efficacy of comprehensive (trunk, hips, knees, and ankles) joint feedback control against postural disturbances using a bipedal, 3-D computer model of SCI stance. Proportional-derivative feedback drove an artificial neural network trained to produce muscle excitation patterns consistent with maximal joint stiffness values achievable about neutral stance given typical SCI muscle properties. Feedback gains were optimized to minimize upper extremity (UE) loading required to stabilize against disturbances. Compared to the baseline case of maximum constant muscle excitations used clinically, the controller reduced UE loading by 55% in resisting external force perturbations and by 84% during simulated one-arm functional tasks. Performance was most sensitive to inaccurate measurements of ankle plantar/dorsiflexion position and hip ab/adduction velocity feedback. In conclusion, comprehensive joint feedback demonstrates potential to markedly improve FNS standing function. However, alternative control structures capable of effective performance with fewer sensor-based feedback parameters may better facilitate clinical usage.

  7. Are Global In-Situ Ocean Observations Fit-for-purpose? Applying the Framework for Ocean Observing in the Atlantic.

    Science.gov (United States)

    Visbeck, M.; Fischer, A. S.; Le Traon, P. Y.; Mowlem, M. C.; Speich, S.; Larkin, K.

    2015-12-01

    There are an increasing number of global, regional and local processes that are in need of integrated ocean information. In the sciences ocean information is needed to support physical ocean and climate studies for example within the World Climate Research Programme and its CLIVAR project, biogeochemical issues as articulated by the GCP, IMBER and SOLAS projects of ICSU-SCOR and Future Earth. This knowledge gets assessed in the area of climate by the IPCC and biodiversity by the IPBES processes. The recently released first World Ocean Assessment focuses more on ecosystem services and there is an expectation that the Sustainable Development Goals and in particular Goal 14 on the Ocean and Seas will generate new demands for integrated ocean observing from Climate to Fish and from Ocean Resources to Safe Navigation and on a healthy, productive and enjoyable ocean in more general terms. In recognition of those increasing needs for integrated ocean information we have recently launched the Horizon 2020 AtlantOS project to promote the transition from a loosely-coordinated set of existing ocean observing activities to a more integrated, more efficient, more sustainable and fit-for-purpose Atlantic Ocean Observing System. AtlantOS takes advantage of the Framework for Ocean observing that provided strategic guidance for the design of the project and its outcome. AtlantOS will advance the requirements and systems design, improving the readiness of observing networks and data systems, and engaging stakeholders around the Atlantic. AtlantOS will bring Atlantic nations together to strengthen their complementary contributions to and benefits from the internationally coordinated Global Ocean Observing System (GOOS) and the Blue Planet Initiative of the Global Earth Observation System of Systems (GEOSS). AtlantOS will fill gaps of the in-situ observing system networks and will ensure that their data are readily accessible and useable. AtlantOS will demonstrate the utility of

  8. [Artificial organs].

    Science.gov (United States)

    Raguin, Thibaut; Dupret-Bories, Agnès; Debry, Christian

    2017-01-01

    Research has been fighting against organ failure and shortage of donations by supplying artificial organs for many years. With the raise of new technologies, tissue engineering and regenerative medicine, many organs can benefit of an artificial equivalent: thanks to retinal implants some blind people can visualize stimuli, an artificial heart can be proposed in case of cardiac failure while awaiting for a heart transplant, artificial larynx enables laryngectomy patients to an almost normal life, while the diabetic can get a glycemic self-regulation controlled by smartphones with an artificial device. Dialysis devices become portable, as well as the oxygenation systems for terminal respiratory failure. Bright prospects are being explored or might emerge in a near future. However, the retrospective assessment of putative side effects is not yet sufficient. Finally, the cost of these new devices is significant even if the advent of three dimensional printers may reduce it. © 2017 médecine/sciences – Inserm.

  9. Spine concerns in the Special Olympian with Down syndrome.

    Science.gov (United States)

    Tassone, James Channing; Duey-Holtz, Allison

    2008-03-01

    As with any child participating in sports, the safety of The Special Olympian participating in athletics is paramount. The preparticipation medical clearance is necessary to ensure these athletes' safety. In response to evidence that 15% of all individuals with Down syndrome have atlanto-occipital and/or atlanto-axial instability or subluxation, the Special Olympics Inc have additionally mandated preparticipation spine clearance for all individuals with Down syndrome. Spine clearance for the Special Olympian is challenging for the healthcare provider. In addition, controversy has arisen surrounding The Special Olympics Inc policy statement. The purposes of this article are to provide healthcare providers with a review of atlanto-occipital and atlanto-axial instability and subluxation, review spine clearance guidelines, discuss the details and controversy surrounding The Special Olympics Inc mandate, and provide recommendations on how to improve screening and ensure safety of the participants based on the current medical literature.

  10. [Psychomotor education and speech therapy when weaning a child off artificial feeding].

    Science.gov (United States)

    Malécot-Le Meur, Gaëlle; Soulez-Larivière, Laure; Abadie, Véronique; Thouvenin, Béatrice; Rastel, Christine; Chalouhi, Christel

    To support children and their families with weaning off artificial nutrition, a psychomotor therapist and speech therapist from the 'Pierre Robin syndrome and congenital sucking-swallowing disorders' specialist rare disease centre at Necker-Enfant Malades hospital in Paris, have set up a joint consultation, as a complement to medical consultations. This programme shows how speech therapy and psychomotor education can complement each other in order to help children and their parents during this difficult period. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. Rubber hand illusion affects joint angle perception.

    Directory of Open Access Journals (Sweden)

    Martin V Butz

    Full Text Available The Rubber Hand Illusion (RHI is a well-established experimental paradigm. It has been shown that the RHI can affect hand location estimates, arm and hand motion towards goals, the subjective visual appearance of the own hand, and the feeling of body ownership. Several studies also indicate that the peri-hand space is partially remapped around the rubber hand. Nonetheless, the question remains if and to what extent the RHI can affect the perception of other body parts. In this study we ask if the RHI can alter the perception of the elbow joint. Participants had to adjust an angular representation on a screen according to their proprioceptive perception of their own elbow joint angle. The results show that the RHI does indeed alter the elbow joint estimation, increasing the agreement with the position and orientation of the artificial hand. Thus, the results show that the brain does not only adjust the perception of the hand in body-relative space, but it also modifies the perception of other body parts. In conclusion, we propose that the brain continuously strives to maintain a consistent internal body image and that this image can be influenced by the available sensory information sources, which are mediated and mapped onto each other by means of a postural, kinematic body model.

  12. PLANNING IN ARTIFICIAL INTELLIGENCE AND ROBOTICS (PAIR

    Directory of Open Access Journals (Sweden)

    Editorial, Foreword

    2016-11-01

    Full Text Available September 18th, 2016Deggendorf, Germanyhttp://robotics.fel.cvut.cz/pair16/Organized by: Artificial Intelligence Center Department of Computer Science Faculty of Electrical Engineering Czech Technical University in PragueTechnicka 2, Prague 6, 166 27, Czech RepublicGuest editors:Jan Faigl (Artificial Intelligence Center, Department of Computer Science, Faculty of Electrical Engineering, Czech Technical University in PragueJiří Vokřínek (Artificial Intelligence Center, Department of Computer Science, Faculty of Electrical Engineering, Czech Technical University in PragueScientific comittee:D. Belter (Poznań University of Technology, PolandW. Dorner (Technische Hochschule Deggendorf, GermanyJ. Faigl (Czech Technical University in PragueT. Krajník (University of Lincoln, United KingdomA. Komenda (Czech Technical University in PragueG. Kupris (Technische Hochschule Deggendorf, GermanyM. Rollo (Czech Technical University in PragueM. Saska (Czech Technical University in PragueJ. Vokřínek (Czech Technical University in PragueV. Vonásek (Czech Technical University in PragueK. Walas (Poznań University of Technology, Poland Foreword:The third year of the student conference on “Planning in Artificial Intelligence and Robotics” (PAIR continues in joining young researchers and students interested in robotics and artificial intelligence. In 2016, we follow the schema of the last year as a joint event with the RoboTour competition in Deggendorf, Germany. Thanks to the great collaboration with Gerald Kupris and Wolfgang Donner from Technische Hochschule Deggendorf and support from Czech Technical University under project No. SVK 26/16/F3 and Bayerisches Staatsministerium der Finanzen, für Landesentwicklung und Heimat, we have been able to provide accommodations and travel support to participants and an invited speaker. Fourteen papers have accepted and listed in the conference program. The papers have been authored by students from Central Europe

  13. Neural network expert system for X-ray analysis of welded joints

    Science.gov (United States)

    Kozlov, V. V.; Lapik, N. V.; Popova, N. V.

    2018-03-01

    The use of intelligent technologies for the automated analysis of product quality is one of the main trends in modern machine building. At the same time, rapid development in various spheres of human activity is experienced by methods associated with the use of artificial neural networks, as the basis for building automated intelligent diagnostic systems. Technologies of machine vision allow one to effectively detect the presence of certain regularities in the analyzed designation, including defects of welded joints according to radiography data.

  14. ERDA artificial heart program workshop. Final report, September 1, 1975--August 31, 1976

    International Nuclear Information System (INIS)

    Kantrowitz, A.; Altieri, F.; Beall, A.

    1976-08-01

    The major conclusions of the ERDA Artificial Heart Program Workshop are that the concept of a biologically compatible mechanical device which can totally replace the heart is sound, that such a device is needed as an alternative to cardiac transplantation and that its development is a realistic goal. The major recommendation of the committee is that an ERDA program with primary orientation toward development of a total heart replacement should continue, with assured funding about 50 percent higher than at present, for a minimum of 3 additional years at which time another major review should take place. To achieve better management of the program it is recommended that the present contract effort be reorganized under one prime contractor with responsibility for development and demonstration of the ERDA artificial heart system. The formation of a joint artificial heart advisory committee to improve coordination between ERDA and NHLI is also recommended. The committee suggests future policies and directions which it believes will lead to more effective use of funds available for specific aspects of the program. These include the nuclear heart source, engine, blood pump, biomaterials and overall system reliability. Possible future goals for the program are also proposed

  15. Cervical Joint Position Sense in Hypobaric Conditions: A Randomized Double-Blind Controlled Trial.

    Science.gov (United States)

    Bagaianu, Diana; Van Tiggelen, Damien; Duvigneaud, N; Stevens, Veerle; Schroyen, Danny; Vissenaeken, Dirk; D'Hondt, Gino; Pitance, Laurent

    2017-09-01

    Well-adapted motor actions require intact and well-integrated information from all of the sensory systems, specifically the visual, vestibular, and somatosensory systems, including proprioception. Proprioception is involved in the sensorimotor control by providing the central nervous system with an updated body schema of the biomechanical and spatial properties of the body parts. With regard to the cervical spine, proprioceptive information from joint and muscle mechanoreceptors is integrated with vestibular and visual feedback to control head position, head orientation, and whole body posture. Postural control is highly complex and proprioception from joints is an important contributor to the system. Altitude has been used as a paradigm to study the mechanisms of postural control. Determining the mechanisms of postural control that are affected by moderate altitude is important as unpressurized aircrafts routinely operate at altitudes where hypoxia may be a concern. Deficits in motor performance arise when the reliance on proprioceptive feedback is abolished either experimentally or because of a disorder. As pilots require good neck motor control to counteract the weight of their head gear and proprioceptive information plays an important role in this process, the aim of this study was to determine if hypoxia at moderate altitudes would impair proprioception measured by joint position sense of the cervical spine in healthy subjects. Thirty-six healthy subjects (Neck Disability Index environment, a hypobaric chamber was used to simulate artificial moderate altitude. Head repositioning error was measured by asking the subject to perform a head-to-neutral task after submaximal flexion-extension and right/left rotation movements, and a head-to-target task, in which the subjects had to return to a 30° right and left rotation position. Exposure to artificial acute moderate altitude of 7,000 feet had no significant effects on cervical joint position sense measured by

  16. Artificial Gravity: Will it Preserve Bone Health on Long-Duration Missions?

    Science.gov (United States)

    Davis-Street, Janis; Paloski, William H.

    2005-01-01

    Prolonged microgravity exposure disrupts bone, muscle, and cardiovascular homeostasis, sensory-motor coordination, immune function, and behavioral performance. Bone loss, in particular, remains a serious impediment to the success of exploration-class missions by increasing the risks of bone fracture and renal stone formation for crew members. Current countermeasures, consisting primarily of resistive and aerobic exercise, have not yet proven fully successful for preventing bone loss during long-duration spaceflight. While other bone-specific countermeasures, such as pharmacological therapy and dietary modifications, are under consideration, countermeasure approaches that simultaneously address multiple physiologic systems may be more desirable for exploration-class missions, particularly if they can provide effective protection at reduced mission resource requirements (up-mass, power, crew time, etc). The most robust of the multi-system approaches under consideration, artificial gravity (AG), could prevent all of the microgravity-related physiological changes from occurring. The potential methods for realizing an artificial gravity countermeasure are reviewed, as well as selected animal and human studies evaluating the effects of artificial gravity on bone function. Future plans for the study of the multi-system effects of artificial gravity include a joint, cooperative international effort that will systematically seek an optimal prescription for intermittent AG to preserve bone, muscle, and cardiovascular function in human subjects deconditioned by 6 degree head-down-tilt-bed rest. It is concluded that AG has great promise as a multi-system countermeasure, but that further research is required to determine the appropriate parameters for implementation of such a countermeasure for exploration-class missions.

  17. Comprehensive Joint Feedback Control for Standing by Functional Neuromuscular Stimulation – a Simulation Study

    Science.gov (United States)

    Nataraj, Raviraj; Audu, Musa L.; Kirsch, Robert F.; Triolo, Ronald J.

    2013-01-01

    Previous investigations of feedback control of standing after spinal cord injury (SCI) using functional neuromuscular stimulation (FNS) have primarily targeted individual joints. This study assesses the potential efficacy of comprehensive (trunk, hips, knees, and ankles) joint-feedback control against postural disturbances using a bipedal, three-dimensional computer model of SCI stance. Proportional-derivative feedback drove an artificial neural network trained to produce muscle excitation patterns consistent with maximal joint stiffness values achievable about neutral stance given typical SCI muscle properties. Feedback gains were optimized to minimize upper extremity (UE) loading required to stabilize against disturbances. Compared to the baseline case of maximum constant muscle excitations used clinically, the controller reduced UE loading by 55% in resisting external force perturbations and by 84% during simulated one-arm functional tasks. Performance was most sensitive to inaccurate measurements of ankle plantar/dorsiflexion position and hip ab/adduction velocity feedback. In conclusion, comprehensive joint-feedback demonstrates potential to markedly improve FNS standing function. However, alternative control structures capable of effective performance with fewer sensor-based feedback parameters may better facilitate clinical usage. PMID:20923741

  18. Biotribology of Cartilage Wear in Knee and Hip Joints Review of Recent Developments

    Science.gov (United States)

    Gulsen, Akdogan; Merve, Goncu; Meltem, Parlak

    2018-01-01

    Nowadays, the problem of wear in the knee and hip joints is an important issue that concerns many people and still requires new solutions. In recent years, researchers dealing with knee and hip articular cartilage erosion continue to investigate the subject in terms of biotribology. In this study, recent developments and studies in this relevant area are been examined. By using the basic principles of tribology, useful new methods that can be used in the field of biotribology can be produced. Artificial joints designed using various materials such as metals, ceramics, polymers and composites are still being studied. New studies in this area will affect the development of implant technology. Different alloys or composites are currently being tested for new implant designs. Moving implants with a risk of wear are tested in laboratory conditions in simulator devices before they are used in the human body. Major topics such as nanotechnology, tissue engineering, orthopedics, tribology, biotribology, lubrication, organ transplantation and artificial organs, which are still important today, will be useful in the search for finding suitable solutions in the future in biotribological studies. This review article aims to provide an overview of in-vitro studies at the theoretical and laboratory conditions that must be performed prior to clinical investigation.

  19. Joint Secrecy for D2D Communications Underlying Cellular Networks

    KAUST Repository

    Hyadi, Amal

    2018-01-15

    In this work, we investigate the ergodic secrecy rate region of a block-fading spectrum-sharing system, where a D2D communication is underlying a cellular channel. We consider that both the primary and the secondary transmissions require their respective transmitted messages to be kept secret from a common eavesdropper under a joint secrecy constraint. The presented results are for three different scenarios, each corresponding to a particular requirement of the cellular system. First, we consider the case of a fair cellular system, and we show that the impact of jointly securing the transmissions can be balanced between the primary and the secondary systems. The second scenario examines the case when the primary network is demanding and requires the secondary transmission to be at a rate that is decodable by the primary receiver, while the last scenario assumes a joint transmission of artificial noise by the primary and the secondary transmitters. For each scenario, we present an achievable ergodic secrecy rate region that can be used as an indicator for the cellular and the D2D systems to agree under which terms the spectrum will be shared.

  20. Joint application of AI techniques, PRA and disturbance analysis methodology to problems in the maintenance and design of nuclear power plants

    International Nuclear Information System (INIS)

    Okrent, D.

    1989-01-01

    This final report summarizes the accomplishments of a two year research project entitled ''Joint Application of Artificial Intelligence Techniques, Probabilistic Risk Analysis, and Disturbance Analysis Methodology to Problems in the Maintenance and Design of Nuclear Power Plants. The objective of this project is to develop and apply appropriate combinations of techniques from artificial intelligence, (AI), reliability and risk analysis and disturbance analysis to well-defined programmatic problems of nuclear power plants. Reactor operations issues were added to those of design and maintenance as the project progressed

  1. Joint application of AI techniques, PRA and disturbance analysis methodology to problems in the maintenance and design of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Okrent, D.

    1989-03-01

    This final report summarizes the accomplishments of a two year research project entitled Joint Application of Artificial Intelligence Techniques, Probabilistic Risk Analysis, and Disturbance Analysis Methodology to Problems in the Maintenance and Design of Nuclear Power Plants. The objective of this project is to develop and apply appropriate combinations of techniques from artificial intelligence, (AI), reliability and risk analysis and disturbance analysis to well-defined programmatic problems of nuclear power plants. Reactor operations issues were added to those of design and maintenance as the project progressed.

  2. Efficacy of combined pranoprofen eye drops and artificial tears on the treatment of mild to moderate dry eye syndrome after trabbeculectomy

    Directory of Open Access Journals (Sweden)

    Guang-Ming Zhao

    2015-02-01

    Full Text Available AIM:To evaluate the efficacy of combined pranoprofen eye drops and artificial tears on the treatment of mild to moderate dry eye syndrome after trabbeculectomy. METHODS: This prospective case control study included 63 cases(63 eyesof patients with mild to moderate dry eye syndrome after trabbeculectomy in our hospital from November 2013 to June 2013. All subjects were randomly divided into two groups. Observation group was treated with combined pranoprofen eye drops and artificial tears and control group received simple artificial tears marking the eyes at 1, 2, 4wk. The patient's symptoms, signs, BUT, SⅠt, and FL were observed before treatment and 1, 2, 4wk after treatment. RESULTS:After 2wk, the symptoms of observation group were improved, there was statistically significant difference(PPPPCONCLUSION: Artificial tears joint pranoprofen eye drops has good curative effect in the treatment of mild to moderate dry eye syndrome after trabbeculectomy.

  3. Pneumatic artificial muscle actuators for compliant robotic manipulators

    Science.gov (United States)

    Robinson, Ryan Michael

    Robotic systems are increasingly being utilized in applications that require interaction with humans. In order to enable safe physical human-robot interaction, light weight and compliant manipulation are desirable. These requirements are problematic for many conventional actuation systems, which are often heavy, and typically use high stiffness to achieve high performance, leading to large impact forces upon collision. However, pneumatic artificial muscles (PAMs) are actuators that can satisfy these safety requirements while offering power-to-weight ratios comparable to those of conventional actuators. PAMs are extremely lightweight actuators that produce force in response to pressurization. These muscles demonstrate natural compliance, but have a nonlinear force-contraction profile that complicates modeling and control. This body of research presents solutions to the challenges associated with the implementation of PAMs as actuators in robotic manipulators, particularly with regard to modeling, design, and control. An existing PAM force balance model was modified to incorporate elliptic end geometry and a hyper-elastic constitutive relationship, dramatically improving predictions of PAM behavior at high contraction. Utilizing this improved model, two proof-of-concept PAM-driven manipulators were designed and constructed; design features included parallel placement of actuators and a tendon-link joint design. Genetic algorithm search heuristics were employed to determine an optimal joint geometry; allowing a manipulator to achieve a desired torque profile while minimizing the required PAM pressure. Performance of the manipulators was evaluated in both simulation and experiment employing various linear and nonlinear control strategies. These included output feedback techniques, such as proportional-integral-derivative (PID) and fuzzy logic, a model-based control for computed torque, and more advanced controllers, such as sliding mode, adaptive sliding mode, and

  4. Microstructure examination and microhardness of friction stir welded joint of (AA7020-O after PWHT

    Directory of Open Access Journals (Sweden)

    Ghada M.F. Essa

    2018-04-01

    Full Text Available This paper studies the microstructure and microhardness of the welded joints of the annealed aluminum alloy AA7020-O produced by friction stir welding (FSW technique. The material was applied to post weld heat treatment (solution treatment and artificially aged, T6. The traverse speed and the rotational speed are the most important process parameters of FSW, and have great influence on the heat input of the welding operation which governs the welded joints quality. To investigate their effect, the welding operation was performed using three traverse speeds, 20, 40 and 60 mm/s with two rotational speeds of 1125 and 1400 rpm, and other welding parameters were kept constant to produce comparable joints. It was found that the two rotational speeds are accepted with lower traverse speeds to produce sound joints. Microstructure of the welded joints was significantly affected by the FSW process parameters, and slight effect was reported for the grain size. Microhardness examination showed high weld joint quality with respect to the base metal hardness, which proves the reprecipitation of the hardening phase in the weld zone. The microhardness profile was strongly dependant on the rotational speed, and the average values of the joints hardness have increased with the decrease in the rotational speed, where it have been slightly affected by the welding speed. Keywords: Friction stir welding, Aluminum alloy, Mechanical properties, Microstructures

  5. Artificial intelligence

    CERN Document Server

    Ennals, J R

    1987-01-01

    Artificial Intelligence: State of the Art Report is a two-part report consisting of the invited papers and the analysis. The editor first gives an introduction to the invited papers before presenting each paper and the analysis, and then concludes with the list of references related to the study. The invited papers explore the various aspects of artificial intelligence. The analysis part assesses the major advances in artificial intelligence and provides a balanced analysis of the state of the art in this field. The Bibliography compiles the most important published material on the subject of

  6. Quadriplegia in a child following adenotonsillectomy.

    Science.gov (United States)

    Agarwal, J; Tandon, M S; Singh, D; Ganjoo, P

    2013-05-01

    Neurological deterioration in a child following routine surgery, although rare, has potentially life threatening consequences. We report the case of a child who, following adentonsillectomy, developed quadriplegia and acute respiratory distress due to previously undetected atlanto-axial instability. Patients with atlanto-axial instability often have mild or non-specific symptoms, despite severe cervical cord compression. Subtle manifestations may be ignored or attributed to other disease processes, which render patients with undiagnosed atlanto-axial instability at risk of serious neurological injury during general anaesthesia, particularly at the time of laryngoscopy and tracheal intubation. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  7. [Development and application of artificial vertebral body].

    Science.gov (United States)

    Liu, Jian-Tao; Zhang, Feng; Gao, Zheng-Chao; Niu, Bin-Bin; Li, Yu-Huan; He, Xi-Jing

    2017-12-25

    Artificial vertebral body has achieved good results in treating spinal tumors, tuberculosis, fracture and other diseases. Currently, artificial vertebral body with variety of kinds and pros and cons, is generally divided into two types: fusion type and movable type. The former according to whether the height could be adjusted and strength of self-stability is divided into three types: support-fixed type, adjust-fixed type and self-fixed type. Whether the height of self-fixed type could be adjusted is dependent on structure of collar thread rotation. The latter is due to mobile device of ball-and-socket joints or hollow structures instead of the disc which retains the activity of the spine to some extent. Materials of artificial vertebral body include metals, ceramics, biomaterials, polymer composites and other materials. Titanium with a dominant role in the metal has developed to the third generation, but there are still defects such as poor surface bioactivity; ceramics with the representative of hydroxyapatite composite, magnetic bioceramics, polycrystalline alumina ceramics and so on, which have the defects of processing complex and uneven mechanical properties; biological material is mainly dominated by xenogeneic bone, which is closest to human bone in structure and properties, but has defects of low toughness and complex production; polymer composites according to biological characteristics in general consists of biodegradable type and non-biodegradable type which are respectively represented by poly-lactide and polyethylene, each with advantages and disadvantages. Although the design and materials of prosthesis have made great progress, it is difficult to fully meet requirements of spinal implants and they need be further optimized. 3D printing technology makes process of the complex structure of prosthesis and individual customization possible and has broad development prospects. However, long production cycles and high cost of defect should be overcome

  8. Effects of aging treatment and heat input on the microstructures and mechanical properties of TIG-welded 6061-T6 alloy joints

    Science.gov (United States)

    Peng, Dong; Shen, Jun; Tang, Qin; Wu, Cui-ping; Zhou, Yan-bing

    2013-03-01

    Aging treatment and various heat input conditions were adopted to investigate the microstructural evolution and mechanical properties of TIG welded 6061-T6 alloy joints by microstructural observations, microhardness tests, and tensile tests. With an increase in heat input, the width of the heat-affected zone (HAZ) increases and grains in the fusion zone (FZ) coarsen. Moreover, the hardness of the HAZ decreases, whereas that of the FZ decreases initially and then increases with an increase in heat input. Low heat input results in the low ultimate tensile strength of the welded joints due to the presence of partial penetrations and pores in the welded joints. After a simple artificial aging treatment at 175°C for 8 h, the microstructure of the welded joints changes slightly. The mechanical properties of the welded joints enhance significantly after the aging process as few precipitates distribute in the welded seam.

  9. Vision and spectroscopic sensing for joint tracing in narrow gap laser butt welding

    Science.gov (United States)

    Nilsen, Morgan; Sikström, Fredrik; Christiansson, Anna-Karin; Ancona, Antonio

    2017-11-01

    The automated laser beam butt welding process is sensitive to positioning the laser beam with respect to the joint because a small offset may result in detrimental lack of sidewall fusion. This problem is even more pronounced in case of narrow gap butt welding, where most of the commercial automatic joint tracing systems fail to detect the exact position and size of the gap. In this work, a dual vision and spectroscopic sensing approach is proposed to trace narrow gap butt joints during laser welding. The system consists of a camera with suitable illumination and matched optical filters and a fast miniature spectrometer. An image processing algorithm of the camera recordings has been developed in order to estimate the laser spot position relative to the joint position. The spectral emissions from the laser induced plasma plume have been acquired by the spectrometer, and based on the measurements of the intensities of selected lines of the spectrum, the electron temperature signal has been calculated and correlated to variations of process conditions. The individual performances of these two systems have been experimentally investigated and evaluated offline by data from several welding experiments, where artificial abrupt as well as gradual deviations of the laser beam out of the joint were produced. Results indicate that a combination of the information provided by the vision and spectroscopic systems is beneficial for development of a hybrid sensing system for joint tracing.

  10. First-principles data-driven discovery of transition metal oxides for artificial photosynthesis

    Science.gov (United States)

    Yan, Qimin

    We develop a first-principles data-driven approach for rapid identification of transition metal oxide (TMO) light absorbers and photocatalysts for artificial photosynthesis using the Materials Project. Initially focusing on Cr, V, and Mn-based ternary TMOs in the database, we design a broadly-applicable multiple-layer screening workflow automating density functional theory (DFT) and hybrid functional calculations of bulk and surface electronic and magnetic structures. We further assess the electrochemical stability of TMOs in aqueous environments from computed Pourbaix diagrams. Several promising earth-abundant low band-gap TMO compounds with desirable band edge energies and electrochemical stability are identified by our computational efforts and then synergistically evaluated using high-throughput synthesis and photoelectrochemical screening techniques by our experimental collaborators at Caltech. Our joint theory-experiment effort has successfully identified new earth-abundant copper and manganese vanadate complex oxides that meet highly demanding requirements for photoanodes, substantially expanding the known space of such materials. By integrating theory and experiment, we validate our approach and develop important new insights into structure-property relationships for TMOs for oxygen evolution photocatalysts, paving the way for use of first-principles data-driven techniques in future applications. This work is supported by the Materials Project Predictive Modeling Center and the Joint Center for Artificial Photosynthesis through the U.S. Department of Energy, Office of Basic Energy Sciences, Materials Sciences and Engineering Division, under Contract No. DE-AC02-05CH11231. Computational resources also provided by the Department of Energy through the National Energy Supercomputing Center.

  11. Artificial Leaf Based on Artificial Photosynthesis for Solar Fuel Production

    Science.gov (United States)

    2017-06-30

    collect light energy and separate charge for developing new types of nanobiodevices to construct ”artificial leaf” from solar to fuel. or Concept of...AFRL-AFOSR-JP-TR-2017-0054 Artificial Leaf Based on Artificial Photosynthesis for Solar Fuel Production Mamoru Nango NAGOYA INSTITUTE OF TECHNOLOGY...display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION. 1. REPORT DATE (DD-MM-YYYY)      30-06-2017 2

  12. Arthroscopic procedures and therapeutic results of anatomical reconstruction of the coracoclavicular ligaments for acromioclavicular Joint dislocation.

    Science.gov (United States)

    Takase, K; Yamamoto, K

    2016-09-01

    Surgical treatment is recommended for type 5 acromioclavicular joint dislocation on Rockwood's classification. We believe that anatomic repair of the coracoclavicular ligaments best restores the function of the acromioclavicular joint. We attempted to correctly reconstruct the anatomy of the coracoclavicular ligaments under arthroscopy, and describe the minimally invasive arthroscopic procedure. There were 22 patients; mean age at surgery, 38.1 years. Mean time to surgery was 13.2 days. Mean follow-up was 3 years 2 months. The palmaris longus tendon was excised from the ipsilateral side to replace the conoid ligament, while artificial ligament was used for reconstructing the trapezoid ligament. Both ligament reconstructions were performed arthroscopically. No temporary fixation of the acromioclavicular joint was performed. On postoperative radiographic evaluation, 4 patients showed subluxation and 2 showed dislocation of the acromioclavicular joint; the other 16 patients had maintained reduction at the final consultation. MR images 1year after surgery clearly revealed the reconstructed ligaments in 19 patients. Only 1 patient showed osteoarthritis of the acromioclavicular joint. Although it requires resection of the ipsilateral palmaris longus for grafting, we believe that anatomic reconstruction of both coracoclavicular ligaments best restores the function of the acromioclavicular joint. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. FAA/NASA Joint University Program for Air Transportation Research 1994-1995

    Science.gov (United States)

    Remer, J. H.

    1998-01-01

    The Joint University Program for Air Transportation Research (JUP) is a coordinated set of three grants co-sponsored by the Federal Aviation Administration (FAA) and the National Aeronautics and Space Administration (NASA). Under JUP, three institutions: the Massachusetts Institute of Technology, Princeton, and Ohio Universities receive research grants and collaborate with FAA and NASA in defining and performing civil aeronautics research in a multitude of areas. Some of these disciplines are artificial intelligence, control theory, atmospheric hazards, navigation, avionics, human factors, flight dynamics, air traffic management, and electronic communications.

  14. Joint application of AI techniques, PRA and disturbance analysis methodology to problems in the maintenance and design of nuclear power plants. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Okrent, D.

    1989-03-01

    This final report summarizes the accomplishments of a two year research project entitled ``Joint Application of Artificial Intelligence Techniques, Probabilistic Risk Analysis, and Disturbance Analysis Methodology to Problems in the Maintenance and Design of Nuclear Power Plants. The objective of this project is to develop and apply appropriate combinations of techniques from artificial intelligence, (AI), reliability and risk analysis and disturbance analysis to well-defined programmatic problems of nuclear power plants. Reactor operations issues were added to those of design and maintenance as the project progressed.

  15. Generative Artificial Intelligence : Philosophy and Theory of Artificial Intelligence

    NARCIS (Netherlands)

    van der Zant, Tijn; Kouw, Matthijs; Schomaker, Lambertus; Mueller, Vincent C.

    2013-01-01

    The closed systems of contemporary Artificial Intelligence do not seem to lead to intelligent machines in the near future. What is needed are open-ended systems with non-linear properties in order to create interesting properties for the scaffolding of an artificial mind. Using post-structuralistic

  16. Artificial life and Piaget.

    Science.gov (United States)

    Mueller, Ulrich; Grobman, K H.

    2003-04-01

    Artificial life provides important theoretical and methodological tools for the investigation of Piaget's developmental theory. This new method uses artificial neural networks to simulate living phenomena in a computer. A recent study by Parisi and Schlesinger suggests that artificial life might reinvigorate the Piagetian framework. We contrast artificial life with traditional cognitivist approaches, discuss the role of innateness in development, and examine the relation between physiological and psychological explanations of intelligent behaviour.

  17. An analysis of a joint shear model for jointed media with orthogonal joint sets

    International Nuclear Information System (INIS)

    Koteras, J.R.

    1991-10-01

    This report describes a joint shear model used in conjunction with a computational model for jointed media with orthogonal joint sets. The joint shear model allows nonlinear behavior for both joint sets. Because nonlinear behavior is allowed for both joint sets, a great many cases must be considered to fully describe the joint shear behavior of the jointed medium. An extensive set of equations is required to describe the joint shear stress and slip displacements that can occur for all the various cases. This report examines possible methods for simplifying this set of equations so that the model can be implemented efficiently form a computational standpoint. The shear model must be examined carefully to obtain a computationally efficient implementation that does not lead to numerical problems. The application to fractures in rock is discussed. 5 refs., 4 figs

  18. A Description of Skeletal Manifestation in Adult Case of Morquio Syndrome: Radiographic and MRI Appearance

    Directory of Open Access Journals (Sweden)

    Annalisa Di Cesare

    2012-01-01

    Full Text Available We report on a rare case of Morquio syndrome, an autosomal recessive mucopolysaccharidosis including type IVA, a deficiency of N-acetylgalctosamine-6-sulfatase and type IVB a deficiency of β-galactosidase. A 43-year-old female patient affected by IVB Morquio syndrome underwent instrumental investigation. Conventional plain films of the entire spine, pelvis, chest and knees together with magnetic resonance imaging of the entire column, hip, knees, and ankles demonstrated the characteristics of skeletal changes of this disease. The main abnormalities were platyspondily and hypoplasia of the odontoid process, genua valga deformity and severe multiple degenerative changes of the hips, knees, and ankle joints. Radiographs and above all magnetic resonance imaging are crucial to provide substantial information about the gravity, evolution of the skeletal and joints changes, and the rehabilitation strategies to be followed.

  19. Corrosion in artificial saliva of a Ni-Cr-based dental alloy joined by TIG welding and conventional brazing.

    Science.gov (United States)

    Matos, Irma C; Bastos, Ivan N; Diniz, Marília G; de Miranda, Mauro S

    2015-08-01

    Fixed prosthesis and partial dental prosthesis frameworks are usually made from welded Ni-Cr-based alloys. These structures can corrode in saliva and have to be investigated to establish their safety. The purpose of this study was to evaluate the corrosion behavior of joints joined by tungsten inert gas (TIG) welding and conventional brazing in specimens made of commercial Ni-Cr alloy in Fusayama artificial saliva at 37°C (pH 2.5 and 5.5). Eighteen Ni-Cr base metal specimens were cast and welded by brazing or tungsten inert gas methods. The specimens were divided into 3 groups (base metal, 2 welded specimens), and the composition and microstructure were qualitatively evaluated. The results of potential corrosion and corrosion current density were analyzed with a 1-way analysis of variance and the Tukey test for pairwise comparisons (α=.05). Base metal and tungsten inert gas welded material showed equivalent results in electrochemical corrosion tests, while the air-torched specimens exhibited low corrosion resistance. The performance was worst at pH 2.5. These results suggest that tungsten inert gas is a suitable welding process for use in dentistry, because the final microstructure does not reduce the corrosion resistance in artificial saliva at 37°C, even in a corrosion-testing medium that facilitates galvanic corrosion processes. Moreover, the corrosion current density of brazed Ni-Cr alloy joints was significantly higher (P<.001) than the base metal and tungsten inert gas welded joints. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Artificial sweeteners

    DEFF Research Database (Denmark)

    Raben, Anne Birgitte; Richelsen, Bjørn

    2012-01-01

    Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie-containin......Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie......-containing sweeteners. The purpose of this review is to summarize the current evidence on the effect of artificial sweeteners on body weight, appetite, and risk markers for diabetes and CVD in humans....

  1. Artificial cognition architectures

    CERN Document Server

    Crowder, James A; Friess, Shelli A

    2013-01-01

    The goal of this book is to establish the foundation, principles, theory, and concepts that are the backbone of real, autonomous Artificial Intelligence. Presented here are some basic human intelligence concepts framed for Artificial Intelligence systems. These include concepts like Metacognition and Metamemory, along with architectural constructs for Artificial Intelligence versions of human brain functions like the prefrontal cortex. Also presented are possible hardware and software architectures that lend themselves to learning, reasoning, and self-evolution

  2. Effect of carbon ion implantation on the tribology of metal-on-metal bearings for artificial joints

    Directory of Open Access Journals (Sweden)

    Koseki H

    2017-05-01

    Full Text Available Hironobu Koseki,1 Masato Tomita,2 Akihiko Yonekura,2 Takashi Higuchi,1 Sinya Sunagawa,2 Koumei Baba,3,4 Makoto Osaki2 1Department of Locomotive Rehabilitation Science, Unit of Rehabilitation Sciences, 2Department of Orthopedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, Sakamoto, Nagasaki, Japan; 3Industrial Technology Center of Nagasaki, Ikeda, Omura, Nagasaki, Japan; 4Affiliated Division, Nagasaki University School of Engineering, Bunkyo, Nagasaki, Japan Abstract: Metal-on-metal (MoM bearings have become popular due to a major advantage over metal-on-polymer bearings for total hip arthroplasty in that the larger femoral head and hydrodynamic lubrication of the former reduce the rate of wear. However, concerns remain regarding adverse reactions to metal debris including metallosis caused by metal wear generated at the taper-head interface and another modular junction. Our group has hypothesized that carbon ion implantation (CII may improve metal wear properties. The purpose of this study was to investigate the wear properties and friction coefficients of CII surfaces with an aim to ultimately apply these surfaces to MoM bearings in artificial joints. CII was applied to cobalt-chromium-molybdenum (Co-Cr-Mo alloy substrates by plasma source ion implantation. The substrates were characterized using scanning electron microscopy and a 3D measuring laser microscope. Sliding contact tests were performed with a simple geometry pin-on-plate wear tester at a load of 2.5 N, a calculated contact pressure of 38.5 MPa (max: 57.8 MPa, a reciprocating velocity of 30 mm/s, a stroke length of 60 mm, and a reciprocating cycle count of 172,800 cycles. The surfaces of the CII substrates were generally featureless with a smooth surface topography at the same level as untreated Co-Cr-Mo alloy. Compared to the untreated Co-Cr-Mo alloy, the CII-treated bearings had lower friction coefficients, higher resistance to catastrophic damage, and

  3. Synovial fluid lubrication of artificial joints: protein film formation and composition.

    Science.gov (United States)

    Fan, Jingyun; Myant, Connor; Underwood, Richard; Cann, Philippa

    2012-01-01

    Despite design improvements, wear of artificial implants remains a serious health issue particularly for Metal-on-Metal (MoM) hips where the formation of metallic wear debris has been linked to adverse tissue response. Clearly it is important to understand the fundamental lubrication mechanisms which control the wear process. It is usually assumed that MoM hips operate in the ElastoHydrodynamic Lubrication (EHL) regime where film formation is governed by the bulk fluid viscosity; however there is little experimental evidence of this. The current paper critically examines synovial fluid lubrication mechanisms and the effect of synovial fluid chemistry. Two composition parameters were chosen; protein content and pH, both of which are known to change in diseased or post-operative synovial fluid. Film thickness and wear tests were carried out for a series of model synovial fluid solutions. Two distinct film formation mechanisms were identified; an adsorbed surface film and a high-viscosity gel. The entrainment of this gel controls film formation particularly at low speeds. However wear of the femoral head still occurs and this is thought to be due primarily to a tribo-corrosion mechanisms. The implications of this new lubrication mechanism and the effect of different synovial fluid chemistries are examined. One important conclusion is that patient synovial fluid chemistry plays an important role in determining implant wear and the likelihood of failure.

  4. Artificial Disc Replacement

    Science.gov (United States)

    ... Spondylolisthesis BLOG FIND A SPECIALIST Treatments Artificial Disc Replacement (ADR) Patient Education Committee Jamie Baisden The disc ... Disc An artificial disc (also called a disc replacement, disc prosthesis or spine arthroplasty device) is a ...

  5. The biomechanical assessment of the cervical inter-vertebral kinematics, between DDD patients ICR based study

    Science.gov (United States)

    Saveh, Amir Hossein; Zali, Ali Reza; Seddighi, Amir Saeed; Zarghi, Afsaneh; Chizari, Mahmoud; Hanafiah, Yussof

    2012-01-01

    Abstract: It is very important to pay more attention to spine from the biomechanical perspective. It would allow the analysis of initial conditions of the vertebral disc degeneration syndrome and adopting of normal spine kinematics to compare and match it with a degenerated disc and providing a biomechanical index as an indicator for the conduct of any surgical intervention including arthroplasty to maximize restoring spinal biomechanical motion. It is clear that the head movement is possible with the help of muscles. However, the shape and type of motion depends on the structure and shape of the cervical spine and the interaction between them. Cervical spine kinematics depends on the anatomy of the bones and joints. Bazhdok et al (2000) investigated the cervical kinematics and mechanical behavior of the spine and its anatomical connections. They have examined the atlanto- occipital joint motion during flexion-extension and rotation as well as the mechanism of paradoxical motion of atlanto- axial joint by radiography. Bifalkou et al (2011) studied the inter-vertebral motion based on arc kinematic commentary of video fluoroscopy. They showed that the diagnosis of biomechanical instability can be done based on the kinematic examination of the spine obtained in sagittal images. They also declared that the fluoroscopy can be used as a tool for study. Using an automated algorithm, image adaption was carried out and the motion direction of vertebrae was tracked. In the present study, some patients were selected among patients with cervical disc degeneration. Following imaging by fluoroscopy, the instantaneous center of the spinal action was calculated. It was used as a biomechanical criterion and the treatment group was compared with the healthy group. The loci of the instantaneous centers of the two groups were compared and its difference with the value of healthy group was calculated. A biomechanical criterion was introduced as a basis for comparison of normal and

  6. Evaluation of Artificial Caudal Fin for Fish Robot with Two Joints by Using Three-Dimensional Fluid-Structure Simulation

    Directory of Open Access Journals (Sweden)

    Yogo Takada

    2013-01-01

    Full Text Available A fish robot with image sensors is useful to research for underwater creatures such as fish. However, the propulsion velocity of a fish robot is very slow compared with live fish. It is necessary to swim at a speed several times faster than the speed of the current robots for various usages. Therefore, we are searching for the method of making the robot swim fast. The simulation before making the robot is important. We have made the computational simulation program of three-dimensional fluid-structure analysis. The flow around the caudal fin can be examined by analyzing the fin as an elastic body. We compared the results of numerical analysis with the results of PIV measurement. Both were agreed well. Because the performance of a fish robot with two joints is better than that of a fish robot with one joint, we searched for an excellent fin for the fish robot with two joints by using CFD. We confirmed that the swimming performance of a fish robot becomes very good when the caudal fin is rigid except for the root of the fin which is comparatively flexible.

  7. Artificial life and life artificialization in Tron

    Directory of Open Access Journals (Sweden)

    Carolina Dantas Figueiredo

    2012-12-01

    Full Text Available Cinema constantly shows the struggle between the men and artificial intelligences. Fiction, and more specifically fiction films, lends itself to explore possibilities asking “what if?”. “What if”, in this case, is related to the eventual rebellion of artificial intelligences, theme explored in the movies Tron (1982 and Tron Legacy (2010 trat portray the conflict between programs and users. The present paper examines these films, observing particularly the possibility programs empowering. Finally, is briefly mentioned the concept of cyborg as a possibility of response to human concerns.

  8. MR diagnosis of temporomandibular joint. A study of joint effusion

    International Nuclear Information System (INIS)

    Kaneda, Takashi; Yamashiro, Mitsuaki; Ozawa, Kaoru; Suzuki, Hiromi; Okada, Hiroyuki; Yamamoto, Hirotsugu

    1998-01-01

    The purposes of this study were to evaluate the relationship between correlation of MR joint effusion of the temporomandibular joint and disk position, to evaluate the relationship between joint effusion and aging, and to assess the frequency of MR joint effusion of bilateral temporomandibular joints. The temporomandibular joints of 192 patients with clinical symptoms of temporomandibular joint disorders were imaged bilaterally using high field, surface-coil MR imaging. Oblique sagittal and coronal proton density-weighted and T2-weighted images were obtained. Imaging findings of joint effusion were correlated with disk position, aging, and bilateral temporomandibular joints. MR showed effusion in 4% of the joints with normal superior disk position, 36% of the joints with disk displacement with reduction, and 45% of the joints with disk displacement without reduction. There were significant differences in the incidence of joint effusion between normal disk position and anterior disk displacement with or without reduction. Younger patients less than 40 years were significant higher the incidence of joint effusion than those of older patients. A significant association was seen between joint effusion and aging. MR showed effusion in 17% of the unilateral temporomandibular joint, 24% of the bilateral temporomandibular joints. There was no significant difference between unilateral and bilateral case. These results indicated that joint effusion using MR imaging was associated with varied temporomandibular joint pathologic states. (author)

  9. Joint German/French S4-Analytical Report

    International Nuclear Information System (INIS)

    Miemczyk, H.

    1979-03-01

    A joint German/French program was initiated to investigate in detail the behaviour of artificially defected fuel pins in a sodium loop of the SILOE reactor at Grenoble/France. Three irradiation experiments have been conducted in SILOE on representative SNR-type fuel pins (mixed oxide, low density, stainless steel cladding, external diameter 6 mm). The first experiment, S2, had been an unirradiated pin with a large interstitial defect (machined slit of 30x1 mm). The two following pins, S4 and S3, have been pre-irradiated in RAPSODIE (365 efpd, 10.6 % burnup). The main results of the S4-experiment are described and evaluated in the present report. They concern the following important aspects: sodium-uranate/plutonate formation and its kinetics, fuel loss, fission product release and fuel behaviour

  10. Neural network based automated algorithm to identify joint locations on hand/wrist radiographs for arthritis assessment

    International Nuclear Information System (INIS)

    Duryea, J.; Zaim, S.; Wolfe, F.

    2002-01-01

    Arthritis is a significant and costly healthcare problem that requires objective and quantifiable methods to evaluate its progression. Here we describe software that can automatically determine the locations of seven joints in the proximal hand and wrist that demonstrate arthritic changes. These are the five carpometacarpal (CMC1, CMC2, CMC3, CMC4, CMC5), radiocarpal (RC), and the scaphocapitate (SC) joints. The algorithm was based on an artificial neural network (ANN) that was trained using independent sets of digitized hand radiographs and manually identified joint locations. The algorithm used landmarks determined automatically by software developed in our previous work as starting points. Other than requiring user input of the location of nonanatomical structures and the orientation of the hand on the film, the procedure was fully automated. The software was tested on two datasets: 50 digitized hand radiographs from patients participating in a large clinical study, and 60 from subjects participating in arthritis research studies and who had mild to moderate rheumatoid arthritis (RA). It was evaluated by a comparison to joint locations determined by a trained radiologist using manual tracing. The success rate for determining the CMC, RC, and SC joints was 87%-99%, for normal hands and 81%-99% for RA hands. This is a first step in performing an automated computer-aided assessment of wrist joints for arthritis progression. The software provides landmarks that will be used by subsequent image processing routines to analyze each joint individually for structural changes such as erosions and joint space narrowing

  11. [Total artificial heart].

    Science.gov (United States)

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  12. Artificial Intelligence in Astronomy

    Science.gov (United States)

    Devinney, E. J.; Prša, A.; Guinan, E. F.; Degeorge, M.

    2010-12-01

    From the perspective (and bias) as Eclipsing Binary researchers, we give a brief overview of the development of Artificial Intelligence (AI) applications, describe major application areas of AI in astronomy, and illustrate the power of an AI approach in an application developed under the EBAI (Eclipsing Binaries via Artificial Intelligence) project, which employs Artificial Neural Network technology for estimating light curve solution parameters of eclipsing binary systems.

  13. [Preparation of nano-nacre artificial bone].

    Science.gov (United States)

    Chen, Jian-ting; Tang, Yong-zhi; Zhang, Jian-gang; Wang, Jian-jun; Xiao, Ying

    2008-12-01

    To assess the improvements in the properties of nano-nacre artificial bone prepared on the basis of nacre/polylactide acid composite artificial bone and its potential for clinical use. The compound of nano-scale nacre powder and poly-D, L-lactide acid (PDLLA) was used to prepare the cylindrical hollow artificial bone, whose properties including raw material powder scale, pore size, porosity and biomechanical characteristics were compared with another artificial bone made of micron-scale nacre powder and PDLLA. Scanning electron microscope showed that the average particle size of the nano-nacre powder was 50.4-/+12.4 nm, and the average pore size of the artificial bone prepared using nano-nacre powder was 215.7-/+77.5 microm, as compared with the particle size of the micron-scale nacre powder of 5.0-/+3.0 microm and the pore size of the resultant artificial bone of 205.1-/+72.0 microm. The porosities of nano-nacre artificial bone and the micron-nacre artificial bone were (65.4-/+2.9)% and (53.4-/+2.2)%, respectively, and the two artificial bones had comparable compressive strength and Young's modulus, but the flexural strength of the nano-nacre artificial bone was lower than that of the micro-nacre artificial bone. The nano-nacre artificial bone allows better biodegradability and possesses appropriate pore size, porosity and biomechanical properties for use as a promising material in bone tissue engineering.

  14. Estimation of continuous multi-DOF finger joint kinematics from surface EMG using a multi-output Gaussian Process.

    Science.gov (United States)

    Ngeo, Jimson; Tamei, Tomoya; Shibata, Tomohiro

    2014-01-01

    Surface electromyographic (EMG) signals have often been used in estimating upper and lower limb dynamics and kinematics for the purpose of controlling robotic devices such as robot prosthesis and finger exoskeletons. However, in estimating multiple and a high number of degrees-of-freedom (DOF) kinematics from EMG, output DOFs are usually estimated independently. In this study, we estimate finger joint kinematics from EMG signals using a multi-output convolved Gaussian Process (Multi-output Full GP) that considers dependencies between outputs. We show that estimation of finger joints from muscle activation inputs can be improved by using a regression model that considers inherent coupling or correlation within the hand and finger joints. We also provide a comparison of estimation performance between different regression methods, such as Artificial Neural Networks (ANN) which is used by many of the related studies. We show that using a multi-output GP gives improved estimation compared to multi-output ANN and even dedicated or independent regression models.

  15. Optimal design for laser beam butt welding process parameter using artificial neural networks and genetic algorithm for super austenitic stainless steel

    Science.gov (United States)

    Sathiya, P.; Panneerselvam, K.; Soundararajan, R.

    2012-09-01

    Laser welding input parameters play a very significant role in determining the quality of a weld joint. The joint quality can be defined in terms of properties such as weld bead geometry, mechanical properties and distortion. Therefore, mechanical properties should be controlled to obtain good welded joints. In this study, the weld bead geometry such as depth of penetration (DP), bead width (BW) and tensile strength (TS) of the laser welded butt joints made of AISI 904L super austenitic stainless steel were investigated. Full factorial design was used to carry out the experimental design. Artificial Neural networks (ANN) program was developed in MatLab software to establish the relationships between the laser welding input parameters like beam power, travel speed and focal position and the three responses DP, BW and TS in three different shielding gases (Argon, Helium and Nitrogen). The established models were used for optimizing the process parameters using Genetic Algorithm (GA). Optimum solutions for the three different gases and their respective responses were obtained. Confirmation experiment has also been conducted to validate the optimized parameters obtained from GA.

  16. Amplify scientific discovery with artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Gil, Yolanda; Greaves, Mark T.; Hendler, James; Hirsch, Hyam

    2014-10-10

    Computing innovations have fundamentally changed many aspects of scientific inquiry. For example, advances in robotics, high-end computing, networking, and databases now underlie much of what we do in science such as gene sequencing, general number crunching, sharing information between scientists, and analyzing large amounts of data. As computing has evolved at a rapid pace, so too has its impact in science, with the most recent computing innovations repeatedly being brought to bear to facilitate new forms of inquiry. Recently, advances in Artificial Intelligence (AI) have deeply penetrated many consumer sectors, including for example Apple’s Siri™ speech recognition system, real-time automated language translation services, and a new generation of self-driving cars and self-navigating drones. However, AI has yet to achieve comparable levels of penetration in scientific inquiry, despite its tremendous potential in aiding computers to help scientists tackle tasks that require scientific reasoning. We contend that advances in AI will transform the practice of science as we are increasingly able to effectively and jointly harness human and machine intelligence in the pursuit of major scientific challenges.

  17. Artificial Intelligence Study (AIS).

    Science.gov (United States)

    1987-02-01

    ARTIFICIAL INTELLIGNECE HARDWARE ....... 2-50 AI Architecture ................................... 2-49 AI Hardware ....................................... 2...ftf1 829 ARTIFICIAL INTELLIGENCE STUDY (RIS)(U) MAY CONCEPTS 1/3 A~NLYSIS AGENCY BETHESA RD R B NOJESKI FED 6? CM-RP-97-1 NCASIFIED /01/6 M |K 1.0...p/ - - ., e -- CAA- RP- 87-1 SAOFŔ)11 I ARTIFICIAL INTELLIGENCE STUDY (AIS) tNo DTICFEBRUARY 1987 LECT 00 I PREPARED BY RESEARCH AND ANALYSIS

  18. Prediction of Tensile Strength of Friction Stir Weld Joints with Adaptive Neuro-Fuzzy Inference System (ANFIS) and Neural Network

    Science.gov (United States)

    Dewan, Mohammad W.; Huggett, Daniel J.; Liao, T. Warren; Wahab, Muhammad A.; Okeil, Ayman M.

    2015-01-01

    Friction-stir-welding (FSW) is a solid-state joining process where joint properties are dependent on welding process parameters. In the current study three critical process parameters including spindle speed (??), plunge force (????), and welding speed (??) are considered key factors in the determination of ultimate tensile strength (UTS) of welded aluminum alloy joints. A total of 73 weld schedules were welded and tensile properties were subsequently obtained experimentally. It is observed that all three process parameters have direct influence on UTS of the welded joints. Utilizing experimental data, an optimized adaptive neuro-fuzzy inference system (ANFIS) model has been developed to predict UTS of FSW joints. A total of 1200 models were developed by varying the number of membership functions (MFs), type of MFs, and combination of four input variables (??,??,????,??????) utilizing a MATLAB platform. Note EFI denotes an empirical force index derived from the three process parameters. For comparison, optimized artificial neural network (ANN) models were also developed to predict UTS from FSW process parameters. By comparing ANFIS and ANN predicted results, it was found that optimized ANFIS models provide better results than ANN. This newly developed best ANFIS model could be utilized for prediction of UTS of FSW joints.

  19. Prediction of Weld Penetration in FCAW of HSLA steel using Artificial Neural Networks

    International Nuclear Information System (INIS)

    Asl, Y. Dadgar; Mostafa, N. B.; Panahizadeh, V. R.; Seyedkashi, S. M. H.

    2011-01-01

    Flux-cored arc welding (FCAW) is a semiautomatic or automatic arc welding process that requires a continuously-fed consumable tubular electrode containing a flux. The main FCAW process parameters affecting the depth of penetration are welding current, arc voltage, nozzle-to-work distance, torch angle and welding speed. Shallow depth of penetration may contribute to failure of a welded structure since penetration determines the stress-carrying capacity of a welded joint. To avoid such occurrences; the welding process parameters influencing the weld penetration must be properly selected to obtain an acceptable weld penetration and hence a high quality joint. Artificial neural networks (ANN), also called neural networks (NN), are computational models used to express complex non-linear relationships between input and output data. In this paper, artificial neural network (ANN) method is used to predict the effects of welding current, arc voltage, nozzle-to-work distance, torch angle and welding speed on weld penetration depth in gas shielded FCAW of a grade of high strength low alloy steel. 32 experimental runs were carried out using the bead-on-plate welding technique. Weld penetrations were measured and on the basis of these 32 sets of experimental data, a feed-forward back-propagation neural network was created. 28 sets of the experiments were used as the training data and the remaining 4 sets were used for the testing phase of the network. The ANN has one hidden layer with eight neurons and is trained after 840 iterations. The comparison between the experimental results and ANN results showed that the trained network could predict the effects of the FCAW process parameters on weld penetration adequately.

  20. Dysphagia in the Elderly Following Anterior Cervical Surgery: A Multidisciplinary Approach

    LENUS (Irish Health Repository)

    Osuafor, C N.

    2017-11-01

    Dysphagia is a risk factor for adverse health outcomes like aspiration, recurrent chest infections and malnutrition. Here, we describe a case of an 82-year-old lady who presented with a two-month history of dysphagia after an anterior odontoid screw fixation for a type II odontoid process fracture. This case highlights the importance of a multidisciplinary approach to patient care.

  1. Quo Vadis, Artificial Intelligence?

    OpenAIRE

    Berrar, Daniel; Sato, Naoyuki; Schuster, Alfons

    2010-01-01

    Since its conception in the mid 1950s, artificial intelligence with its great ambition to understand and emulate intelligence in natural and artificial environments alike is now a truly multidisciplinary field that reaches out and is inspired by a great diversity of other fields. Rapid advances in research and technology in various fields have created environments into which artificial intelligence could embed itself naturally and comfortably. Neuroscience with its desire to understand nervou...

  2. Inteligencia artificial en vehiculo

    OpenAIRE

    Amador Díaz, Pedro

    2012-01-01

    Desarrollo de un robot seguidor de líneas, en el que se implementan diversas soluciones de las áreas de sistemas embebidos e inteligencia artificial. Desenvolupament d'un robot seguidor de línies, en el qual s'implementen diverses solucions de les àrees de sistemes encastats i intel·ligència artificial. Follower robot development of lines, in which various solutions are implemented in the areas of artificial intelligence embedded systems.

  3. Electromyogram synergy control of a dexterous artificial hand to unscrew and screw objects.

    Science.gov (United States)

    Kent, Benjamin A; Karnati, Nareen; Engeberg, Erik D

    2014-03-21

    Due to their limited dexterity, it is currently not possible to use a commercially available prosthetic hand to unscrew or screw objects without using elbow and shoulder movements. For these tasks, prosthetic hands function like a wrench, which is unnatural and limits their use in tight working environments. Results from timed rotational tasks with human subjects demonstrate the clinical need for increased dexterity of prosthetic hands, and a clinically viable solution to this problem is presented for an anthropomorphic artificial hand. Initially, a human hand motion analysis was performed during a rotational task. From these data, human hand synergies were derived and mapped to an anthropomorphic artificial hand. The synergy for the artificial hand is controlled using conventional dual site electromyogram (EMG) signals. These EMG signals were mapped to the developed synergy to control four joints of the dexterous artificial hand simultaneously.Five limb absent and ten able-bodied test subjects participated in a comparison study to complete a timed rotational task as quickly as possible with their natural hands (except for one subject with a bilateral hand absence), eight commercially available prosthetic hands, and the proposed synergy controller. Each test subject used two to four different artificial hands. With the able-bodied subjects, the developed synergy controller reduced task completion time by 177% on average. The limb absent subjects completed the task faster on average than with their own prostheses by 46%. There was a statistically significant improvement in task completion time with the synergy controller for three of the four limb absent participants with integrated prostheses, and was not statistically different for the fourth. The proposed synergy controller reduced average task completion time compared to commercially available prostheses. Additionally, the synergy controller is able to function in a small workspace and requires less physical

  4. International joint research of medical and walfare appliances; Iryo fukushi kiki kokusai kyodo kenkyu jigyo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    To further elevate the medical level and to actively enhance Japan`s contribution to the world in its effort to properly meet the task of advancing longevity of men common to all the advanced countries, investigations were made to study how international joint research should be conducted in the field of medical and welfare appliances. Candidate projects in international joint research and investigations up to fiscal 1993 were arranged, and explanation was made about the strategic and long-term research and development projects (started in fiscal 1995) about medical and welfare appliances undertaken by the Ministry of Trade and Industry of Japan. The two are quite similar to each other, the Ministry of Trade and Industry program comprising six projects that are micropores collection of blood/microdose analysis, high precision three dimensional image assisted diagnosis, less invasive surgery, artificial organs, care assisting intelligent equipment, and welfare equipment for care at home, centering about which international joint research should be propelled. Visits were made to the scenes of research and development of advanced medical and welfare appliances in the U.S. and Canada and their actual state was studied in search for possible joint researches. Further, research and development institutions in Europe were visited and information was exchanged. 25 figs., 15 tabs.

  5. Criminal Aspects of Artificial Abortion

    OpenAIRE

    Hartmanová, Leona

    2016-01-01

    Criminal Aspects of Artificial Abortion This diploma thesis deals with the issue of artificial abortion, especially its criminal aspects. Legal aspects are not the most important aspects of artificial abortion. Social, ethical or ideological aspects are of the same importance but this diploma thesis cannot analyse all of them. The main issue with artificial abortion is whether it is possible to force a pregnant woman to carry a child and give birth to a child when she cannot or does not want ...

  6. Control of an automated mobile manipulator using artificial immune system

    Science.gov (United States)

    Deepak, B. B. V. L.; Parhi, Dayal R.

    2016-03-01

    This paper addresses the coordination and control of a wheeled mobile manipulator (WMM) using artificial immune system. The aim of the developed methodology is to navigate the system autonomously and transport jobs and tools in manufacturing environments. This study integrates the kinematic structures of a four-axis manipulator and a differential wheeled mobile platform. The motion of the developed WMM is controlled by the complete system of parametric equation in terms of joint velocities and makes the robot to follow desired trajectories by the manipulator and platform within its workspace. The developed robot system performs its action intelligently according to the sensed environmental criteria within its search space. To verify the effectiveness of the proposed immune-based motion planner for WMM, simulations as well as experimental results are presented in various unknown environments.

  7. Artificial Hydration and Nutrition

    Science.gov (United States)

    ... Crisis Situations Pets and Animals myhealthfinder Food and Nutrition Healthy Food Choices Weight Loss and Diet Plans ... Your Health Resources Healthcare Management Artificial Hydration and Nutrition Artificial Hydration and Nutrition Share Print Patients who ...

  8. Artificial Evolution for the Detection of Group Identities in Complex Artificial Societies

    DEFF Research Database (Denmark)

    Grappiolo, Corrado; Togelius, Julian; Yannakakis, Georgios N.

    2013-01-01

    This paper aims at detecting the presence of group structures in complex artificial societies by solely observing and analysing the interactions occurring among the artificial agents. Our approach combines: (1) an unsupervised method for clustering interactions into two possible classes, namely in...

  9. Artificial intelligence

    International Nuclear Information System (INIS)

    Perret-Galix, D.

    1992-01-01

    A vivid example of the growing need for frontier physics experiments to make use of frontier technology is in the field of artificial intelligence and related themes. This was reflected in the second international workshop on 'Software Engineering, Artificial Intelligence and Expert Systems in High Energy and Nuclear Physics' which took place from 13-18 January at France Telecom's Agelonde site at La Londe des Maures, Provence. It was the second in a series, the first having been held at Lyon in 1990

  10. Determination of Parachute Joint Factors using Seam and Joint Testing

    Science.gov (United States)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  11. Temporomandibular joint space in children without joint disease

    International Nuclear Information System (INIS)

    Larheim, T.A.

    1981-01-01

    Bilateral assessment of the temporomandibular joint space in children without joint disease is reported. Twenty-eight children were examined with conventional radiography and 23 with tomography. High prevalence of asymmetric joint spaces with both techniques indicated that great care should be taken when using narrowing or widening of the joint space as a diagnostic criterion in children with juvenile rheumatoid arthritis. Other signs, such as restricted translation of the mandibular head, and clinical symptoms should be evaluated. (Auth.)

  12. Continuous Estimation of Human Multi-Joint Angles From sEMG Using a State-Space Model.

    Science.gov (United States)

    Ding, Qichuan; Han, Jianda; Zhao, Xingang

    2017-09-01

    Due to the couplings among joint-relative muscles, it is a challenge to accurately estimate continuous multi-joint movements from multi-channel sEMG signals. Traditional approaches always build a nonlinear regression model, such as artificial neural network, to predict the multi-joint movement variables using sEMG as inputs. However, the redundant sEMG-data are always not distinguished; the prediction errors cannot be evaluated and corrected online as well. In this work, a correlation-based redundancy-segmentation method is proposed to segment the sEMG-vector including redundancy into irredundant and redundant subvectors. Then, a general state-space framework is developed to build the motion model by regarding the irredundant subvector as input and the redundant one as measurement output. With the built state-space motion model, a closed-loop prediction-correction algorithm, i.e., the unscented Kalman filter (UKF), can be employed to estimate the multi-joint angles from sEMG, where the redundant sEMG-data are used to reject model uncertainties. After having fully employed the redundancy, the proposed method can provide accurate and smooth estimation results. Comprehensive experiments are conducted on the multi-joint movements of the upper limb. The maximum RMSE of the estimations obtained by the proposed method is 0.16±0.03, which is significantly less than 0.25±0.06 and 0.27±0.07 (p < 0.05) obtained by common neural networks.

  13. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    Science.gov (United States)

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Optimization of laser welding process parameters for super austenitic stainless steel using artificial neural networks and genetic algorithm

    International Nuclear Information System (INIS)

    Sathiya, P.; Panneerselvam, K.; Abdul Jaleel, M.Y.

    2012-01-01

    Highlights: ► Super austenitic stainless steel has successfully welded by laser welding with three different shielding gases. ► Among the three shielded joints, the helium shielded weld has more tensile strength. ► Neural network model was developed to predict the depth of penetration, bead width and tensile strength of the joints. ► The developed ANN model is suitably integrated with GA for optimization. -- Abstract: The laser welding input parameters play a very significant role in determining the quality of a weld joint. The quality of the joint can be defined in terms of properties such as weld bead geometry, mechanical properties and distortion. In particular mechanical properties should be controlled to obtain good welded joints. In this study, the weld bead geometry such as depth of penetration (DP), bead width (BW) and tensile strength (TS) of the laser welded butt joints made of AISI 904L super austenitic stainless steel are investigated. Full factorial design is used to carry out the experimental design. Artificial neural networks (ANNs) program was developed in MatLab software to establish the relationship between the laser welding input parameters like beam power, travel speed and focal position and the three responses DP, BW and TS in three different shielding gases (argon, helium and nitrogen). The established models are used for optimizing the process parameters using genetic algorithm (GA). Optimum solutions for the three different gases and their respective responses are obtained. Confirmation experiment has also been conducted to validate the optimized parameters obtained from GA.

  15. Biological factors of natural and artificial ecosystems stable (unstable) functioning

    Science.gov (United States)

    Pechurkin, Nikolai S.

    The problem of sustainable development of humanity on Earth and the problem of supporting human life in space have the same scientific and methodological bases. The key to solve both problems is a long term maintenance of balanced material cycle. As a whole, natural or artificial ecosystems are to be more closed than open, but their elements (links of systems) are to be substantially open in interactions with each other. Prolonged stable interactions of different links have to have unique joint results - closed material cycling or biotic turnover. It is necessary to include, at least, three types of main links into any system to support real material cycling: producers, consumers, reducers. Producer links are now under studies in many laboratories. It is evident that the higher productivity of link, the lower link stability. Especially, it concerns with parasite impact to plants. As usual, artificial ecosystems are more simple (incomplete) than natural ecosystems, sometimes, they have not enough links for prolonged stable functioning. For example, life support system for space flight can be incomplete in consumer link, having only some crew persons, instead of interacting populations of consumers. As for reducer link, it is necessary to "organize" a special coordinated work of microbial biocenoses to fulfill proper cycling. Possible evolution of links, their self development is a matter of special attention for the maintenance of prolonged stable functioning. It's the most danger for systems with populations of quickly reproducing, so-called, R - strategists, according to symbols of logistic equation. From another side, quick reproduction of R - strategists is able to increase artificial ecosystems and their links functioning. After some damages of system, R - strategist's link can be quickly "self repaired" up to level of normal functioning. Some experimental data of this kind and mathematical models are to be discussed in the paper. This work is supported by

  16. The Japanese artificial organs scene: current status.

    Science.gov (United States)

    Mitamura, Yoshinori; Murabayashi, Shun

    2005-08-01

    Artificial organs and regenerative medicine are the subjects of very active research and development (R&D) in Japan and various artificial organs are widely used in patients. Results of the R&D are presented at the annual conference of the Japanese Society for Artificial Organs (JSAO). Progress in the fields of artificial organs and regenerative medicine are reviewed annually in the Japanese Journal of Artificial Organs. The official English-language journal of JSAO, Journal of Artificial Organs, also publishes many original articles by Japanese researchers. Although the annual conference and the publications of JSAO provide the world with update information on artificial organs and regenerative medicine in Japan, the information is not always understood appropriately in the rest of the world, mainly due to language problems. This article therefore introduces the current status of artificial organs and regenerative medicine in Japan. Artificial hearts and metabolic support systems are reviewed here and other interesting areas such as regenerative medicine can be found elsewhere.

  17. Nondestructive evaluation of adhesive joints by C-scan ultrasonic testing

    International Nuclear Information System (INIS)

    Zeighami, Mehdi; Honarvar, Farhang

    2009-01-01

    Evaluation of the quality of adhesive bonding is an important issue in many industries who incorporate adhesive joints in their products. Over the past few decades, numerous acoustical techniques have been developed for nondestructive testing (NDT) of adhesively bonded joints. Among these techniques, the ultrasonic pulse-echo method is the most promising means for inspection of adhesive bonds. In practice, due to low impedance matching between adhesive and metal, the discrimination of a good bond from a bad bond is difficult. The low impedance matching also results in low contrast between perfect and disbanded zone in a C-scan image. In this paper, the quality of the interface between aluminum and epoxy is investigated by using an in-house built ultrasonic C-scan system. Two adhesion indices are proposed for producing C-scan images. To verify the capability of these indices, an adhesively bonded sample was fabricated using aluminum plates and epoxy. An artificial defect was implanted in the first interface of the specimens. The C-scan measurement prepared based on the proposed indices was able to reveal the defect much better than the C-scan image prepared by conventional approach. (author)

  18. Changes in Chopart joint load following tibiotalar arthrodesis: in vitro analysis of 8 cadaver specimen in a dynamic model

    Directory of Open Access Journals (Sweden)

    Herberts T

    2007-08-01

    Full Text Available Abstract Background In the current discussion of surgical treatment of arthroses in the ankle joint, arthrodesis is in competition with artificial joint replacement. Up until now, no valid biomechanical findings have existed on the changes in intraarticular loads following arthrodesis. One argument against tibiotalar arthrodesis is the frequently associated, long-term degeneration of the talonavicular joint, which can be attributed to changes in biomechanical stresses. Methods We used a dynamic model to determine the changes in intraarticular forces and peak-pressure in the talonavicular joint and in the calcaneocuboid joint on 8 cadaver feet under stress in a simulated stance phase following tibiotalar arthrodesis. Results The change seen after arthrodesis was a tendency of relocation of average force and maximum pressure from the lateral onto the medial column of the foot. The average force increased from native 92 N to 100 N upon arthrodesis in the talonavicular joint and decreased in the calcaneocuboid joint from 54 N to 48 N. The peak pressure increased from native 3.9 MPa to 4.4 MPa in the talonavicular joint and in the calcaneocuboid joint from 3.3 MPa to 3.4 MPa. The increase of force and peak pressure on the talonavicular joint and decrease of force on the calcaneocuboid joint is statistically significant. Conclusion The increase in imparted force and peak pressure on the medial column of the foot following tibiotalar arthrodesis, as was demonstrated in a dynamic model, biomechanically explains the clinically observed phenomenon of cartilage degeneration on the medial dorsum of the foot in the long term. As a clinical conclusion from the measurements, it would be desirable to reduce the force imparted on the medial column with displacement onto the lateral forefoot, say by suitable shoe adjustment, in order to achieve a more favourable long-term clinical result.

  19. Integration of robotics and neuroscience beyond the hand: What kind of synergies?. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by Marco Santello et al.

    Science.gov (United States)

    d'Avella, Andrea

    2016-07-01

    Santello et al. [1] review an impressive amount of work on the control of biological and artificial hands that demonstrates how the concept of synergies can lead to a successful integration of robotics and neuroscience. Is it possible to generalize the same approach to the control of biological and artificial limbs and bodies beyond the hand? The human hand synergies that appear most relevant for robotic hands are those defined at the kinematic level, i.e. postural synergies [2]. Postural synergies capture the geometric relations among the many joints of the hand and allow for a low dimensional characterization and synthesis of the static hand postures involved in grasping and manipulating a large set of objects. However, many other complex motor skills such as walking, reaching, throwing, and catching require controlling multi-articular time-varying trajectories rather than static postures. Dynamic control of biological and artificial limbs and bodies, especially when geometric and inertial parameters are uncertain and the joints are compliant, poses great challenges. What kind of synergies might simplify the dynamic control of motor skills involving upper and lower limbs as well as the whole body?

  20. Soft computing in artificial intelligence

    CERN Document Server

    Matson, Eric

    2014-01-01

    This book explores the concept of artificial intelligence based on knowledge-based algorithms. Given the current hardware and software technologies and artificial intelligence theories, we can think of how efficient to provide a solution, how best to implement a model and how successful to achieve it. This edition provides readers with the most recent progress and novel solutions in artificial intelligence. This book aims at presenting the research results and solutions of applications in relevance with artificial intelligence technologies. We propose to researchers and practitioners some methods to advance the intelligent systems and apply artificial intelligence to specific or general purpose. This book consists of 13 contributions that feature fuzzy (r, s)-minimal pre- and β-open sets, handling big coocurrence matrices, Xie-Beni-type fuzzy cluster validation, fuzzy c-regression models, combination of genetic algorithm and ant colony optimization, building expert system, fuzzy logic and neural network, ind...

  1. Joint Replacement (Finger and Wrist Joints)

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Joint Replacement Email to a friend * required fields ...

  2. Joint Operation Planning

    National Research Council Canada - National Science Library

    2006-01-01

    .... It sets forth joint doctrine to govern the joint operation planning activities and performance of the Armed Forces of the United States in joint operations, and provides the joint doctrinal basis...

  3. Jointness for the Rest of Us: Reforming Joint Professional Development

    Science.gov (United States)

    2016-06-10

    transferred to the Joint Staff. 13 DOD’s instinct to “overly centralize planning, organization, and management.”20 The authors contend that this...2. 3 John F. Schank and others, Who is Joint? Reevaluating the Joint Duty Assignment List : A Study Prepared for the Joint Staff, by the RAND...and code those billets as such. Once identified, DOD must expand the Joint Duty Assignment List (JDAL) to include billets that offer enlisted personnel

  4. 4th International Joint Conference on Computational Intelligence

    CERN Document Server

    Correia, António; Rosa, Agostinho; Filipe, Joaquim

    2015-01-01

    The present book includes extended and revised versions of a set of selected papers from the Fourth International Joint Conference on Computational Intelligence (IJCCI 2012)., held in Barcelona, Spain, from 5 to 7 October, 2012. The conference was sponsored by the Institute for Systems and Technologies of Information, Control and Communication (INSTICC) and was organized in cooperation with the Association for the Advancement of Artificial Intelligence (AAAI). The conference brought together researchers, engineers and practitioners in computational technologies, especially those related to the areas of fuzzy computation, evolutionary computation and neural computation. It is composed of three co-located conferences, each one specialized in one of the aforementioned -knowledge areas. Namely: - International Conference on Evolutionary Computation Theory and Applications (ECTA) - International Conference on Fuzzy Computation Theory and Applications (FCTA) - International Conference on Neural Computation Theory a...

  5. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    Science.gov (United States)

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Design of a Lightweight Soft Robotic Arm Using Pneumatic Artificial Muscles and Inflatable Sleeves.

    Science.gov (United States)

    Ohta, Preston; Valle, Luis; King, Jonathan; Low, Kevin; Yi, Jaehyun; Atkeson, Christopher G; Park, Yong-Lae

    2018-04-01

    As robots begin to interact with humans and operate in human environments, safety becomes a major concern. Conventional robots, although reliable and consistent, can cause injury to anyone within its range of motion. Soft robotics, wherein systems are made to be soft and mechanically compliant, are thus a promising alternative due to their lightweight nature and ability to cushion impacts, but current designs often sacrifice accuracy and usefulness for safety. We, therefore, have developed a bioinspired robotic arm combining elements of rigid and soft robotics such that it exhibits the positive qualities of both, namely compliance and accuracy, while maintaining a low weight. This article describes the design of a robotic arm-wrist-hand system with seven degrees of freedom (DOFs). The shoulder and elbow each has two DOFs for two perpendicular rotational motions on each joint, and the hand has two DOFs for wrist rotations and one DOF for a grasp motion. The arm is pneumatically powered using custom-built McKibben type pneumatic artificial muscles, which are inflated and deflated using binary and proportional valves. The wrist and hand motions are actuated through servomotors. In addition to the actuators, the arm is equipped with a potentiometer in each joint for detecting joint angle changes. Simulation and experimental results for closed-loop position control are also presented in the article.

  7. A morphological study of the hip joint of coxarthrosis by computed tomography

    International Nuclear Information System (INIS)

    Hijikata, Hiromi; Tagawa, Hiroshi; Kashiyama, Masahiro; Yokohata, Yumiko; Kohno, Atsushi; Iida, Keiko

    1983-01-01

    The hip joint in coxarthrosis with severe deformities was studied by CT scan. In this disease, the supero-inferior diameter increased according to the degree of incomplete dislocation, while the antero-posterior diameter remained small. The acetabulum was shallow showing a small distance from the femur axis to the outer plate of the floor, but the floor of the acetabulum was thick with a considerable distance from the axis to the inner plate of the floor. The tangenital angle of the acetabulum was around 20 0 , without remarkable changes depending on the degree of incomplete dislocation. The angle of covering the acetabulum at the center of the capitum was normally around 180 0 , and became smaller in incomplete dislocation, showing poor adaptability. The anterior torsion angle in incomplete dislocation tended to be larger depending upon severity of dislocation. In the cavum medullare of proximal diaphysis of the femur, the antero-posterior diameter was larger than the right-left diameter; and this relation was reversed in the use of artificial joint. Atrophy of the gluteal muscle developed with severeness of coxarthrosis. (Ueda, J.)

  8. Self-healing bolted joint employing a shape memory actuator

    Science.gov (United States)

    Muntges, Daniel E.; Park, Gyuhae; Inman, Daniel J.

    2001-08-01

    This paper is a report of an initial investigation into the active control of preload in the joint using a shape memory actuator around the axis of the bolt shaft. Specifically, the actuator is a cylindrical Nitinol washer that expands axially when heated, according to the shape memory effect. The washer is actuated in response to an artificial decrease in torque. Upon actuation, the stress generated by its axial strain compresses the bolted members and creates a frictional force that has the effect of generating a preload and restoring lost torque. In addition to torque wrenches, the system in question was monitored in all stages of testing using piezoelectric impedance analysis. Impedance analysis drew upon research techniques developed at Center for Intelligent Material Systems and Structures, in which phase changes in the impedance of a self-sensing piezoceramic actuator correspond to changes in joint stiffness. Through experimentation, we have documented a successful actuation of the shape memory element. Due to complexity of constitutive modeling, qualitative analysis by the impedance method is used to illustrate the success. Additional considerations encountered in this initial investigation are made to guide further thorough research required for the successful commercial application of this promising technique.

  9. Coracoclavicular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Sang; Park, Chan Il; Ahn, Jae Doo; Lim, Chong Won [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1970-10-15

    The coracoclvicular joint, a rear abnormality which may be the cause of pain in the shoulder and limitation of motion of the shoulder joint, is discussed. A case of coracoclvicular joint with shoulder pain was observed in 65 yrs old Korean male.

  10. Artificial Intelligence

    CERN Document Server

    Warwick, Kevin

    2011-01-01

    if AI is outside your field, or you know something of the subject and would like to know more then Artificial Intelligence: The Basics is a brilliant primer.' - Nick Smith, Engineering and Technology Magazine November 2011 Artificial Intelligence: The Basics is a concise and cutting-edge introduction to the fast moving world of AI. The author Kevin Warwick, a pioneer in the field, examines issues of what it means to be man or machine and looks at advances in robotics which have blurred the boundaries. Topics covered include: how intelligence can be defined whether machines can 'think' sensory

  11. Charlas sobre inteligencia artificial

    OpenAIRE

    Álvarez Sánchez, José Ramón; Ferrández Vicente, José Manuel; Paz López, Félix de la

    2014-01-01

    Serie: Informática en Radio 3 La Inteligencia Artificial es una de las ciencias que causa mayor impacto en la sociedad, mucho más si tenemos en cuenta que cambiará el futuro de la humanidad. En España existen actualmente un nutrido grupo de equipos de investigación relacionados con las tecnologías de computación natural-artificial que aúnan sus esfuerzos a través de la RTNAC la Red Temática en Tecnologías de Computación Natural-Artificial . La UNED participa en todas sus actividades desde ...

  12. Artificial Intelligence Project

    Science.gov (United States)

    1990-01-01

    Symposium on Aritificial Intelligence and Software Engineering Working Notes, March 1989. Blumenthal, Brad, "An Architecture for Automating...Artificial Intelligence Project Final Technical Report ARO Contract: DAAG29-84-K-OGO Artificial Intelligence LaboratO"ry The University of Texas at...Austin N>.. ~ ~ JA 1/I 1991 n~~~ Austin, Texas 78712 ________k A,.tificial Intelligence Project i Final Technical Report ARO Contract: DAAG29-84-K-0060

  13. Rearing the southern green stink bug using an artificial dry diet and an artificial plant Criação do percevejo-verde usando dieta artificial seca e planta artificial

    Directory of Open Access Journals (Sweden)

    ANTÔNIO RICARDO PANIZZI

    2000-09-01

    Full Text Available Laboratory and greenhouse studies were conducted with an artificial dry diet to rear nymphs, and with an artificial plant as substrate for egg laying by the southern green stink bug, Nezara viridula (L.. The artificial diet was composed of: soybean protein (15 g; potato starch (7.5 g; dextrose (7.5 g; sucrose (2.5 g; cellulose (12.5 g; vitamin mixture (niacinamide 1 g, calcium pantothenate 1 g, thiamine 0.25 g, riboflavin 0.5 g, pyridoxine 0.25 g, folic acid 0.25 g, biotin 0.02 mL, vitamin B12 1 g - added to 1,000 mL of distilled water (5.0 mL; soybean oil (20 mL; wheat germ (17.9 g; and water (30 mL. Nymphs showed normal feeding behavior when fed on the artificial diet. Nymphal development time was longer than or similar to that of nymphs fed on soybean pods. Total nymphal mortality was low (ca. 30%, both for nymphs reared on the artificial diet, and for nymphs fed on soybean pods. At adult emergence, fresh body weights were significantly (PForam conduzidos estudos em laboratório e em casa de vegetação, com uma dieta artificial seca para a criação de ninfas e com um modelo de planta artificial como substrato para a colocação de ovos por adultos do percevejo-verde, Nezara viridula (L.. Os componentes da dieta artificial foram: proteína de soja (15 g; fécula de batata (7,5 g; dextrose (7,5 g; sacarose (2,5 g; celulose (12,5 g; mistura vitamínica (niacinamida 1 g, pantotenato de cálcio 1 g, tiamina 0,25 g, riboflavina 0,5 g, piridoxina 0,25 g, ácido fólico 0,25 g, biotina 0,02 mL, vitamina B12 1 g, adicionada em 1.000 mL de água destilada (5,0 mL; óleo de soja (20 mL; germe de trigo (17,9 g; e água (30 mL. As ninfas alimentaram-se normalmente da dieta, embora o tempo de desenvolvimento tenha sido em um caso, maior, e em outro, semelhante, ao das ninfas que se alimentaram de vagens da soja. A mortalidade total das ninfas foi baixa (ca. 30%, tanto na dieta como na vagem de soja. Na emergência, os adultos apresentaram peso fresco

  14. Temporomandibular joint

    International Nuclear Information System (INIS)

    Westesson, P.L.; Hatala, M.; Tallents, R.H.; Katzberg, R.W.; Musgrave, M.; Levitt, S.

    1990-01-01

    This paper determines the frequency of MR signs of abnormal temporomandibular joints (TMJs) in asymptomatic volunteers. Forty-two volunteers with 84 clinically normal TMJs were imaged in the sagittal and coronal planes with surface coil MR imaging. Sagittal closed and open and coronal closed views were obtained bilaterally in all volunteers. The images were classified as normal (superior disk position) or abnormal (disk displacement of degenerative joint disease). Eighteen joints in 11 volunteers were abnormal; 12 had disk displacement with reduction and six had disk displacement without reduction, with associated degenerative joint disease in three of the six. Asymptomatic internal derangement and degenerative joint disease occur in about one-fourth of asymptomatic volunteers

  15. Radiologic comparison of erosive polyarthritis with prominent interphalangeal involvement

    International Nuclear Information System (INIS)

    Gold, R.H.; Bassett, L.W.; Theros, E.G.

    1982-01-01

    Psoriatic arthritis, Reiter's disease, and multicentric reticulohistiocytosis may manifest prominent interphalangeal joint and cutaneous involvement. All three disorders may also affect the sacroiliac joints and spine. Despite these similarities, there are basic radiologic differences enabling distinction between the three disorders. Erosive osteoarthritis must also be considered in the differential diagnosis of interphalangeal erosive arthritis. Psoriatic erosions are characteristically ill defined, often bilaterally asymmetrical, usually unaccompanied by significant osteoporosis, and frequently associated with florid proliferation of subperiosteal new bone. An unilateral polyarticular pattern, which often occurs in a single ray, is the most prevalent of several patterns of involvement. Reiter's disease exhibits many clinical and radiologic similarities to psoriatic arthritis, but in the former there tends to be selective involvement of the joints of the lower limbs and particularly the feet, with relative sparing of the hands and wrists, while in the latter the joints of the upper and lower limbs tend to be involved to an equal extent. Multicentric reticulohistiocytosis (MR). Lesions predominate in skin and synovium and result in sharply circumscribed, rapidly progressive, strikingly bilaterally symmetrical erosions spreading from joint margins to articular surfaces. Most or all of the diarthrodial joints may be affected, but interphalangeal joint predominance and early and severe atlanto-axial involvement are characteristic. Erosive osteoarthritis is characterized by interphalangeal subchondral erosions, accompanying periosteal new bone that is more subtle than that of psoriatic arthritis, and interphalangeal bony ankylosis that occurs with the same frequency as that of psoriatic arthritis. (orig.)

  16. Beyond AI: Artificial Dreams Conference

    CERN Document Server

    Zackova, Eva; Kelemen, Jozef; Beyond Artificial Intelligence : The Disappearing Human-Machine Divide

    2015-01-01

    This book is an edited collection of chapters based on the papers presented at the conference “Beyond AI: Artificial Dreams” held in Pilsen in November 2012. The aim of the conference was to question deep-rooted ideas of artificial intelligence and cast critical reflection on methods standing at its foundations.  Artificial Dreams epitomize our controversial quest for non-biological intelligence, and therefore the contributors of this book tried to fully exploit such a controversy in their respective chapters, which resulted in an interdisciplinary dialogue between experts from engineering, natural sciences and humanities.   While pursuing the Artificial Dreams, it has become clear that it is still more and more difficult to draw a clear divide between human and machine. And therefore this book tries to portrait such an image of what lies beyond artificial intelligence: we can see the disappearing human-machine divide, a very important phenomenon of nowadays technological society, the phenomenon which i...

  17. Artificial Photosynthesis: Beyond Mimicking Nature

    International Nuclear Information System (INIS)

    Dau, Holger; Fujita, Etsuko; Sun, Licheng

    2017-01-01

    In this Editorial, Guest Editors Holger Dau, Etsuko Fujita, and Licheng Sun introduce the Special Issue of ChemSusChem on “Artificial Photosynthesis for Sustainable Fuels”. Here, they discuss the need for non-fossil based fuels, introduce both biological and artificial photosynthesis, and outline various important concepts in artificial photosynthesis, including molecular and solid-state catalysts for water oxidation and hydrogen evolution, catalytic CO 2 reduction, and photoelectrochemical systems.

  18. Viability of pHEMA Hydrogels as Coating in Human Synovial Joint Prosthesis

    Directory of Open Access Journals (Sweden)

    V.P. Bavaresco

    2002-10-01

    Full Text Available In artificial joints, the bone part is usually substituted by a metallic component with high corrosion and strength resistance while the articular cartilage is replaced by a polymer. Use of thin layer of a compliant material acting as a bearing surface in human replacement joints has recently generated considerable interest. This work analyses the coating of a solid porous substrate of Ultra High Molecular Weight Polyethylene (UHMWPE with a poly (2-hydroxyethyl methacrylate (pHEMA and two sIPN-type blends: pHEMA-cellulose acetate butyrate (CAB and pHEMA-poly (ethyl methacrylate (PEM using 5.0% (w/w of the crosslinking agent and 11.0% (w/w of the linear reinforcing polymer. The wear resistance of the coating materials was evaluated in a TRI PIN ON DISK type equipment and the damage extension was characterized by Scanning Electron Microscopy (SEM. Preliminary qualitative tests were performed with the goal to identifying the hydrogels show the minimal required properties concerning wear strength. The pHEMA coating was completely destroyed during the first wear cycles, characterizing its low shear strength. By the other hand, after the complete experiment, both pHEMA-CAB and pHEMA-PEM blends showed a slightly improvement of abrasive and adhesive wear. This result indicates that the studied blends are promising materials to be used as compliant surfaces in joint prosthesis.

  19. Parallel artificial liquid membrane extraction

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Rasmussen, Knut Einar; Parmer, Marthe Petrine

    2013-01-01

    This paper reports development of a new approach towards analytical liquid-liquid-liquid membrane extraction termed parallel artificial liquid membrane extraction. A donor plate and acceptor plate create a sandwich, in which each sample (human plasma) and acceptor solution is separated by an arti......This paper reports development of a new approach towards analytical liquid-liquid-liquid membrane extraction termed parallel artificial liquid membrane extraction. A donor plate and acceptor plate create a sandwich, in which each sample (human plasma) and acceptor solution is separated...... by an artificial liquid membrane. Parallel artificial liquid membrane extraction is a modification of hollow-fiber liquid-phase microextraction, where the hollow fibers are replaced by flat membranes in a 96-well plate format....

  20. Quantitative assessment of cervical vertebral maturation using cone beam computed tomography in Korean girls.

    Science.gov (United States)

    Byun, Bo-Ram; Kim, Yong-Il; Yamaguchi, Tetsutaro; Maki, Koutaro; Son, Woo-Sung

    2015-01-01

    This study was aimed to examine the correlation between skeletal maturation status and parameters from the odontoid process/body of the second vertebra and the bodies of third and fourth cervical vertebrae and simultaneously build multiple regression models to be able to estimate skeletal maturation status in Korean girls. Hand-wrist radiographs and cone beam computed tomography (CBCT) images were obtained from 74 Korean girls (6-18 years of age). CBCT-generated cervical vertebral maturation (CVM) was used to demarcate the odontoid process and the body of the second cervical vertebra, based on the dentocentral synchondrosis. Correlation coefficient analysis and multiple linear regression analysis were used for each parameter of the cervical vertebrae (P cervical vertebral body and odontoid process, respectively, for the multiple regression models. This suggests that quantitative analysis might be used to estimate skeletal maturation status.

  1. Artificial Intelligence in Space Platforms.

    Science.gov (United States)

    1984-12-01

    computer algorithms, there still appears to be a need for Artificial Inteligence techniques in the navigation area. The reason is that navigaion, in...RD-RI32 679 ARTIFICIAL INTELLIGENCE IN SPACE PLRTFORNSMU AIR FORCE 1/𔃼 INST OF TECH WRIGHT-PRTTERSON AFB OH SCHOOL OF ENGINEERING M A WRIGHT DEC 94...i4 Preface The purpose of this study was to analyze the feasibility of implementing Artificial Intelligence techniques to increase autonomy for

  2. Trimaran Resistance Artificial Neural Network

    Science.gov (United States)

    2011-01-01

    11th International Conference on Fast Sea Transportation FAST 2011, Honolulu, Hawaii, USA, September 2011 Trimaran Resistance Artificial Neural Network Richard...Trimaran Resistance Artificial Neural Network 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e... Artificial Neural Network and is restricted to the center and side-hull configurations tested. The value in the parametric model is that it is able to

  3. Artificial Intelligence and Moral intelligence

    OpenAIRE

    Laura Pana

    2008-01-01

    We discuss the thesis that the implementation of a moral code in the behaviour of artificial intelligent systems needs a specific form of human and artificial intelligence, not just an abstract intelligence. We present intelligence as a system with an internal structure and the structural levels of the moral system, as well as certain characteristics of artificial intelligent agents which can/must be treated as 1- individual entities (with a complex, specialized, autonomous or selfdetermined,...

  4. Artificial Intelligence and Economic Theories

    OpenAIRE

    Marwala, Tshilidzi; Hurwitz, Evan

    2017-01-01

    The advent of artificial intelligence has changed many disciplines such as engineering, social science and economics. Artificial intelligence is a computational technique which is inspired by natural intelligence such as the swarming of birds, the working of the brain and the pathfinding of the ants. These techniques have impact on economic theories. This book studies the impact of artificial intelligence on economic theories, a subject that has not been extensively studied. The theories that...

  5. Internet advertising of artificial tanning in Australia.

    Science.gov (United States)

    Team, Victoria; Markovic, Milica

    2006-08-01

    Artificial tanning, defined as deliberate exposure to ultraviolet rays produced by artificial tanning devices, is a new and emerging public health issue in Australia and globally. Epidemiological research suggests that artificial tanning may contribute to the incidence of melanoma, nonmelanoma skin cancer as well as other health problems. Given that Australia has a high incidence of skin cancer, we have undertaken a study to explore how artificial tanning has been promoted to its users. The aim was to analyze the completeness and accuracy of information about artificial tanning. A content analysis of web sites of tanning salons and distributors of tanning equipment in Australia was conducted. A total of 22 web sites were analyzed. None of the solarium operators or distributors of equipment provided full information about the risks of artificial tanning. Fifty-nine percent of web advertisements had no information and 41% provided only partial information regarding the risks of artificial tanning. Pictures with the image of bronze-tanned bodies, predominantly women, were used by all web advertisers. In light of the success of sun-safety campaigns in Australia, the findings of future epidemiological research on the prevalence of artificial tanning and sociological and anthropological research on why people utilize artificial tanning should be a basis for developing effective targeted health promotion on the elimination of artificial tanning in the country.

  6. Joint resistance measurements of pancake and terminal joints for JT-60SA EF coils

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Murakami, Haruyuki; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2013-11-15

    Highlights: • To evaluate the joint fabrication technology for the JT-60SA EF coils, joint resistance measurements were conducted with a joint sample. • The joint sample was composed of pancake and terminal joints. • The measurements demonstrated that both joints fulfilled the design requirement. • Considering the measurements, the characteristics of both joints were investigated using an analytical model that represents the joints. -- Abstract: To evaluate the joint fabrication technology for the JT-60SA EF coils, joint resistance measurements were conducted using a sample consisting of pancake and terminal joints. Both joints are shake-hands lap joints composed of cable-in-conduit conductors and a pure copper saddle-shaped spacer. The measurements demonstrated that both joints fulfilled the design requirement. Considering these measurements, the characteristics of both joints were investigated using analytical models that represent the joints. The analyses indicated that the characteristics of the conductors used in the joints affect the characteristics of the joints.

  7. Differences in predators of artificial and real songbirds nests: Evidence of bias in artificial nest studies

    Science.gov (United States)

    Frank R. Thompson; Dirk E. Burhans

    2004-01-01

    In the past two decades, many researchers have used artificial nest to measure relative rates of nest predation. Recent comparisons show that real and artificial nests may not be depredated at the same rate, but no one has examined the mechanisms underlying these patterns. We determined differences in predator-specific predation rates of real and artificial nests. we...

  8. Empirical Assessment of the Mean Block Volume of Rock Masses Intersected by Four Joint Sets

    Science.gov (United States)

    Morelli, Gian Luca

    2016-05-01

    The estimation of a representative value for the rock block volume ( V b) is of huge interest in rock engineering in regards to rock mass characterization purposes. However, while mathematical relationships to precisely estimate this parameter from the spacing of joints can be found in literature for rock masses intersected by three dominant joint sets, corresponding relationships do not actually exist when more than three sets occur. In these cases, a consistent assessment of V b can only be achieved by directly measuring the dimensions of several representative natural rock blocks in the field or by means of more sophisticated 3D numerical modeling approaches. However, Palmström's empirical relationship based on the volumetric joint count J v and on a block shape factor β is commonly used in the practice, although strictly valid only for rock masses intersected by three joint sets. Starting from these considerations, the present paper is primarily intended to investigate the reliability of a set of empirical relationships linking the block volume with the indexes most commonly used to characterize the degree of jointing in a rock mass (i.e. the J v and the mean value of the joint set spacings) specifically applicable to rock masses intersected by four sets of persistent discontinuities. Based on the analysis of artificial 3D block assemblies generated using the software AutoCAD, the most accurate best-fit regression has been found between the mean block volume (V_{{{{b}}_{{m}} }}) of tested rock mass samples and the geometric mean value of the spacings of the joint sets delimiting blocks; thus, indicating this mean value as a promising parameter for the preliminary characterization of the block size. Tests on field outcrops have demonstrated that the proposed empirical methodology has the potential of predicting the mean block volume of multiple-set jointed rock masses with an acceptable accuracy for common uses in most practical rock engineering applications.

  9. Joint instability and osteoarthritis.

    Science.gov (United States)

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  10. Asymptomatic ''crowned dens'' calcification in CT images for the craniovertebral junction

    International Nuclear Information System (INIS)

    Kubota, Gen; Mori, Masataka; Fukushima, Tatsuro

    2007-01-01

    Calcification around the odontoid process suggests 'crowned dens' syndrome, when accompanied with acute occipital headache or neck pain and with inflammatory signs. We retrospectively searched for calcification around the odontoid process in routine CT images of 282 patients emcompassing the craniovertebral junction, and found 13 (4.6%) had 'crowned dens' calcifications with neither characteristic symptoms nor signs suggestive for crowned dens' syndrome. Females of older ages frequently showed asymptomatic crowned dens' calcifications. (author)

  11. Joint Instability and Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Darryl Blalock

    2015-01-01

    Full Text Available Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA. Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  12. Fluid-driven origami-inspired artificial muscles

    Science.gov (United States)

    Li, Shuguang; Vogt, Daniel M.; Rus, Daniela; Wood, Robert J.

    2017-12-01

    Artificial muscles hold promise for safe and powerful actuation for myriad common machines and robots. However, the design, fabrication, and implementation of artificial muscles are often limited by their material costs, operating principle, scalability, and single-degree-of-freedom contractile actuation motions. Here we propose an architecture for fluid-driven origami-inspired artificial muscles. This concept requires only a compressible skeleton, a flexible skin, and a fluid medium. A mechanical model is developed to explain the interaction of the three components. A fabrication method is introduced to rapidly manufacture low-cost artificial muscles using various materials and at multiple scales. The artificial muscles can be programed to achieve multiaxial motions including contraction, bending, and torsion. These motions can be aggregated into systems with multiple degrees of freedom, which are able to produce controllable motions at different rates. Our artificial muscles can be driven by fluids at negative pressures (relative to ambient). This feature makes actuation safer than most other fluidic artificial muscles that operate with positive pressures. Experiments reveal that these muscles can contract over 90% of their initial lengths, generate stresses of ˜600 kPa, and produce peak power densities over 2 kW/kg—all equal to, or in excess of, natural muscle. This architecture for artificial muscles opens the door to rapid design and low-cost fabrication of actuation systems for numerous applications at multiple scales, ranging from miniature medical devices to wearable robotic exoskeletons to large deployable structures for space exploration.

  13. Artificial Astrocytes Improve Neural Network Performance

    Science.gov (United States)

    Porto-Pazos, Ana B.; Veiguela, Noha; Mesejo, Pablo; Navarrete, Marta; Alvarellos, Alberto; Ibáñez, Oscar; Pazos, Alejandro; Araque, Alfonso

    2011-01-01

    Compelling evidence indicates the existence of bidirectional communication between astrocytes and neurons. Astrocytes, a type of glial cells classically considered to be passive supportive cells, have been recently demonstrated to be actively involved in the processing and regulation of synaptic information, suggesting that brain function arises from the activity of neuron-glia networks. However, the actual impact of astrocytes in neural network function is largely unknown and its application in artificial intelligence remains untested. We have investigated the consequences of including artificial astrocytes, which present the biologically defined properties involved in astrocyte-neuron communication, on artificial neural network performance. Using connectionist systems and evolutionary algorithms, we have compared the performance of artificial neural networks (NN) and artificial neuron-glia networks (NGN) to solve classification problems. We show that the degree of success of NGN is superior to NN. Analysis of performances of NN with different number of neurons or different architectures indicate that the effects of NGN cannot be accounted for an increased number of network elements, but rather they are specifically due to astrocytes. Furthermore, the relative efficacy of NGN vs. NN increases as the complexity of the network increases. These results indicate that artificial astrocytes improve neural network performance, and established the concept of Artificial Neuron-Glia Networks, which represents a novel concept in Artificial Intelligence with implications in computational science as well as in the understanding of brain function. PMID:21526157

  14. Artificial astrocytes improve neural network performance.

    Directory of Open Access Journals (Sweden)

    Ana B Porto-Pazos

    Full Text Available Compelling evidence indicates the existence of bidirectional communication between astrocytes and neurons. Astrocytes, a type of glial cells classically considered to be passive supportive cells, have been recently demonstrated to be actively involved in the processing and regulation of synaptic information, suggesting that brain function arises from the activity of neuron-glia networks. However, the actual impact of astrocytes in neural network function is largely unknown and its application in artificial intelligence remains untested. We have investigated the consequences of including artificial astrocytes, which present the biologically defined properties involved in astrocyte-neuron communication, on artificial neural network performance. Using connectionist systems and evolutionary algorithms, we have compared the performance of artificial neural networks (NN and artificial neuron-glia networks (NGN to solve classification problems. We show that the degree of success of NGN is superior to NN. Analysis of performances of NN with different number of neurons or different architectures indicate that the effects of NGN cannot be accounted for an increased number of network elements, but rather they are specifically due to astrocytes. Furthermore, the relative efficacy of NGN vs. NN increases as the complexity of the network increases. These results indicate that artificial astrocytes improve neural network performance, and established the concept of Artificial Neuron-Glia Networks, which represents a novel concept in Artificial Intelligence with implications in computational science as well as in the understanding of brain function.

  15. Artificial astrocytes improve neural network performance.

    Science.gov (United States)

    Porto-Pazos, Ana B; Veiguela, Noha; Mesejo, Pablo; Navarrete, Marta; Alvarellos, Alberto; Ibáñez, Oscar; Pazos, Alejandro; Araque, Alfonso

    2011-04-19

    Compelling evidence indicates the existence of bidirectional communication between astrocytes and neurons. Astrocytes, a type of glial cells classically considered to be passive supportive cells, have been recently demonstrated to be actively involved in the processing and regulation of synaptic information, suggesting that brain function arises from the activity of neuron-glia networks. However, the actual impact of astrocytes in neural network function is largely unknown and its application in artificial intelligence remains untested. We have investigated the consequences of including artificial astrocytes, which present the biologically defined properties involved in astrocyte-neuron communication, on artificial neural network performance. Using connectionist systems and evolutionary algorithms, we have compared the performance of artificial neural networks (NN) and artificial neuron-glia networks (NGN) to solve classification problems. We show that the degree of success of NGN is superior to NN. Analysis of performances of NN with different number of neurons or different architectures indicate that the effects of NGN cannot be accounted for an increased number of network elements, but rather they are specifically due to astrocytes. Furthermore, the relative efficacy of NGN vs. NN increases as the complexity of the network increases. These results indicate that artificial astrocytes improve neural network performance, and established the concept of Artificial Neuron-Glia Networks, which represents a novel concept in Artificial Intelligence with implications in computational science as well as in the understanding of brain function.

  16. Artificial organ engineering

    CERN Document Server

    Annesini, Maria Cristina; Piemonte, Vincenzo; Turchetti, Luca

    2017-01-01

    Artificial organs may be considered as small-scale process plants, in which heat, mass and momentum transfer operations and, possibly, chemical transformations are carried out. This book proposes a novel analysis of artificial organs based on the typical bottom-up approach used in process engineering. Starting from a description of the fundamental physico-chemical phenomena involved in the process, the whole system is rebuilt as an interconnected ensemble of elemental unit operations. Each artificial organ is presented with a short introduction provided by expert clinicians. Devices commonly used in clinical practice are reviewed and their performance is assessed and compared by using a mathematical model based approach. Whilst mathematical modelling is a fundamental tool for quantitative descriptions of clinical devices, models are kept simple to remain focused on the essential features of each process. Postgraduate students and researchers in the field of chemical and biomedical engineering will find that t...

  17. International joint ventures

    DEFF Research Database (Denmark)

    Sørensen, Karsten Engsig

    2001-01-01

    The article analysis problems connected with corporate joint ventures. Among others the possible conflicts between the joint venture agreement and the statutes of the companies is examined, as well as certain problems connected to the fact that the joint venture partners have created commen control...... over their joint company....

  18. Introduction to Artificial Neural Networks

    DEFF Research Database (Denmark)

    Larsen, Jan

    1999-01-01

    The note addresses introduction to signal analysis and classification based on artificial feed-forward neural networks.......The note addresses introduction to signal analysis and classification based on artificial feed-forward neural networks....

  19. Joint Chiefs of Staff > About > The Joint Staff > Senior Enlisted Advisor

    Science.gov (United States)

    Skip to main content (Press Enter). Toggle navigation Joint Chiefs of Staff Joint Chiefs of Staff Joint Chiefs of Staff Facebook Twitter YouTube Flickr Blog Instagram Search JCS: Search Search Search JCS: Search Home Media News Photos Videos Publications About The Joint Staff Chairman Vice Chairman

  20. A joint-constraint model for human joints using signed distance-fields

    DEFF Research Database (Denmark)

    Engell-Nørregård, Morten Pol; Abel, Sarah Maria Niebe; Erleben, Kenny

    2012-01-01

    We present a local joint-constraint model for a single joint which is based on distance fields. Our model is fast, general, and well suited for modeling human joints. In this work, we take a geometric approach and model the geometry of the boundary of the feasible region, i.e., the boundary of all...... allowed poses. A region of feasible poses can be built by embedding motion captured data points in a signed distance field. The only assumption is that the feasible poses form a single connected set of angular values. We show how signed distance fields can be used to generate fast and general joint......-joint dependencies, or joints with more than three degrees of freedom. The resolution of the joint-constraints can be tweaked individually for each degree of freedom, which can be used to optimize memory usage. We perform a comparative study of the key-properties of various joint-constraint models, as well...

  1. How to teach artificial organs.

    Science.gov (United States)

    Zapanta, Conrad M; Borovetz, Harvey S; Lysaght, Michael J; Manning, Keefe B

    2011-01-01

    Artificial organs education is often an overlooked field for many bioengineering and biomedical engineering students. The purpose of this article is to describe three different approaches to teaching artificial organs. This article can serve as a reference for those who wish to offer a similar course at their own institutions or incorporate these ideas into existing courses. Artificial organ classes typically fulfill several ABET (Accreditation Board for Engineering and Technology) criteria, including those specific to bioengineering and biomedical engineering programs.

  2. Artificial Neural Network Analysis System

    Science.gov (United States)

    2001-02-27

    Contract No. DASG60-00-M-0201 Purchase request no.: Foot in the Door-01 Title Name: Artificial Neural Network Analysis System Company: Atlantic... Artificial Neural Network Analysis System 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Powell, Bruce C 5d. PROJECT NUMBER 5e. TASK NUMBER...34) 27-02-2001 Report Type N/A Dates Covered (from... to) ("DD MON YYYY") 28-10-2000 27-02-2001 Title and Subtitle Artificial Neural Network Analysis

  3. Estimation of Joint types and Joint Limits from Motion capture data

    DEFF Research Database (Denmark)

    Engell-Nørregård, Morten Pol; Erleben, Kenny

    2009-01-01

    It is time-consuming for an animator to explicitly model joint types and joint limits of articulated figures. In this paper we describe a simple and fast approach to automated joint estimation from motion capture data of articulated figures. Our method will make the joint modeling more efficient ...

  4. Artificial Psychology: The Psychology of AI

    Directory of Open Access Journals (Sweden)

    James A. Crowder

    2013-12-01

    Full Text Available Having artificially intelligent machines that think, learn, reason, experience, and can function autonomously, without supervision, is one of the most intriguing goals in all of Computer Science. As the types of problems we would like machines to solve get more complex, it is becoming a necessary goal as well. One of the many problems associated with this goal is that what learning and reasoning are have so many possible meanings that the solution can easily get lost in the sea of opinions and options. The goal of this paper is to establish some foundational principles, theory, and concepts that we feel are the backbone of real, autonomous Artificial Intelligence. With this fully autonomous, learning, reasoning, artificially intelligent system (an artificial brain, comes the need to possess constructs in its hardware and software that mimic processes and subsystems that exist within the human brain, including intuitive and emotional memory concepts. Presented here is a discussion of the psychological constructs of artificial intelligence and how they might play out in an artificial mind.

  5. Artificial Intelligence in Civil Engineering

    Directory of Open Access Journals (Sweden)

    Pengzhen Lu

    2012-01-01

    Full Text Available Artificial intelligence is a branch of computer science, involved in the research, design, and application of intelligent computer. Traditional methods for modeling and optimizing complex structure systems require huge amounts of computing resources, and artificial-intelligence-based solutions can often provide valuable alternatives for efficiently solving problems in the civil engineering. This paper summarizes recently developed methods and theories in the developing direction for applications of artificial intelligence in civil engineering, including evolutionary computation, neural networks, fuzzy systems, expert system, reasoning, classification, and learning, as well as others like chaos theory, cuckoo search, firefly algorithm, knowledge-based engineering, and simulated annealing. The main research trends are also pointed out in the end. The paper provides an overview of the advances of artificial intelligence applied in civil engineering.

  6. Fluid-driven origami-inspired artificial muscles.

    Science.gov (United States)

    Li, Shuguang; Vogt, Daniel M; Rus, Daniela; Wood, Robert J

    2017-12-12

    Artificial muscles hold promise for safe and powerful actuation for myriad common machines and robots. However, the design, fabrication, and implementation of artificial muscles are often limited by their material costs, operating principle, scalability, and single-degree-of-freedom contractile actuation motions. Here we propose an architecture for fluid-driven origami-inspired artificial muscles. This concept requires only a compressible skeleton, a flexible skin, and a fluid medium. A mechanical model is developed to explain the interaction of the three components. A fabrication method is introduced to rapidly manufacture low-cost artificial muscles using various materials and at multiple scales. The artificial muscles can be programed to achieve multiaxial motions including contraction, bending, and torsion. These motions can be aggregated into systems with multiple degrees of freedom, which are able to produce controllable motions at different rates. Our artificial muscles can be driven by fluids at negative pressures (relative to ambient). This feature makes actuation safer than most other fluidic artificial muscles that operate with positive pressures. Experiments reveal that these muscles can contract over 90% of their initial lengths, generate stresses of ∼600 kPa, and produce peak power densities over 2 kW/kg-all equal to, or in excess of, natural muscle. This architecture for artificial muscles opens the door to rapid design and low-cost fabrication of actuation systems for numerous applications at multiple scales, ranging from miniature medical devices to wearable robotic exoskeletons to large deployable structures for space exploration. Copyright © 2017 the Author(s). Published by PNAS.

  7. Polymeric membrane materials for artificial organs.

    Science.gov (United States)

    Kawakami, Hiroyoshi

    2008-01-01

    Many polymeric materials have already been used in the field of artificial organs. However, the materials used in artificial organs are not necessarily created with the best material selectivity and materials design; therefore, the development of synthesized polymeric membrane materials for artificial organs based on well-defined designs is required. The approaches to the development of biocompatible polymeric materials fall into three categories: (1) control of physicochemical characteristics on material surfaces, (2) modification of material surfaces using biomolecules, and (3) construction of biomimetic membrane surfaces. This review will describe current issues regarding polymeric membrane materials for use in artificial organs.

  8. Artificial reefs: “Attraction versus Production”

    Directory of Open Access Journals (Sweden)

    Eduardo Barros Fagundes Netto

    2011-04-01

    Full Text Available The production of fish is the most common reason for the construction and installation of an artificial reef. More recently, environmental concerns and conservation of biological resources have been instrumental to the formulation of new goals of the research. One of the issues to be resolved is the biological function of “attraction vs. production” as a result of the use of artificial reefs. The uncertainty as to the answer to the question whether the artificial reefs will or not benefit the development of fish stocks could be solved if the artificial reefs would be managed as marine protected areas.

  9. No evidence hip joint angle modulates intrinsically produced stretch reflex in human hopping.

    Science.gov (United States)

    Gibson, W; Campbell, A; Allison, G

    2013-09-01

    Motor output in activities such as walking and hopping is suggested to be mediated neurally by purported stretch reflex augmentation of muscle output. Reflex EMG activity during these tasks has been frequently investigated in the soleus muscle; with alterations in reflex amplitude being associated with changes in hip joint angle/phase of the gait cycle. Previous work has focussed on reflex activity induced by an artificial perturbation or by induction of H-reflexes. As such, it is currently unknown if stretch reflex activity induced intrinsically (as part of the task) is modulated by changes in hip joint angle. This study investigated whether hip joint angle modulated reflex EMG 'burst' activity during a hopping task performed on a custom-built partially reclined sleigh. Ten subjects participated; EMG and kinematic data (VICON motor capture system) was collected for each hop cycle. Participants completed 5 sets of 30s of self-paced hopping in (1) hip neutral and (2) hip 60° flexion conditions. There was no difference in EMG 'burst' activity or in sagittal plane kinematics (knee/ankle) in the hopping task between the two conditions. The results indicate that during a functional task such as hopping, changes in hip angle do not alter the stretch reflex-like activity associated with landing. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Joint reproductive autonomy: does Evans v Amicus Healthcare Ltd provide for a gender-neutral approach to assisted reproductive rights?

    Science.gov (United States)

    Allin, Michael J

    2015-06-01

    Assisted reproductive technology encompasses methods of achieving pregnancy by artificial or partially artificial means. Whilst these methods are more commonly used by couples suffering from problems of infertility, some forms of assistance are employed by fertile couples, for example pre-implantation genetic diagnosis. The overall regulatory framework in the UK is predominantly found in the Human Fertilisation and Embryology Act 1990. The usual rules relating to consent and autonomy apply and were discussed in depth in Evans v Amicus Healthcare Ltd and later in Evans v United Kingdom. This paper considers whether the Evans litigation envisages the possibility of further encouraging joint autonomy in the use of zygotes and whether there is a continuing right to autonomy by the party not bearing the pregnancy. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. High critical current YBa2Cu3O7 artificial joints using Ag foils as welding agent

    International Nuclear Information System (INIS)

    Iliescu, S; Granados, X; Bartolome, E; Sena, S; Carrilllo, A E; Puig, T; Obradors, X; Evetts, J E

    2004-01-01

    A new high quality joining technique of melt processed YBCO has been developed based on interfacial melting induced by a metallic silver foil inserted between two single domain YBCO tiles. This simple technique allows joining large monoliths to form the complex-shaped pieces required for many power applications. Hall probe magnetic flux profile analysis under magnetic field and high field magnetoresistance measurements demonstrate that the superconducting behaviour of the joint is indistinguishable from the bulk

  12. Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end-face apparatus.

    Science.gov (United States)

    Morita, Yusuke; Nakata, Kenichi; Kim, Yoon-Ho; Sekino, Tohru; Niihara, Koichi; Ikeuchi, Ken

    2004-01-01

    While only alumina is applied to all-ceramic joint prostheses at present, a stronger ceramic is required to prevent fracture and chipping due to impingement and stress concentration. Zirconia could be a potential substitute for alumina because it has high strength and fracture toughness. However, the wear of zirconia/zirconia combination is too high for clinical use. Although some investigations on composite ceramics revealed that mixing of different ceramics was able to improve the mechanical properties of ceramics, there are few reports about wear properties of composite ceramics for joint prosthesis. Since acetabular cup and femoral head of artificial hip joint are finished precisely, they indicate high geometric conformity. Therefore, wear test under flat contact was carried out with an end-face wear testing apparatus for four kinds of ceramics: alumina monolith, zirconia monolith, alumina-based composite ceramic, and zirconia based composite ceramic. Mean contact pressure was 10 MPa and sliding velocity was 40 mm/s. The wear test continued for 72 hours and total sliding distance was 10 km. After the test, the wear factor was calculated. Worn surfaces were observed with a scanning electron micrograph (SEM). The results of this wear test show that the wear factors of the both composite ceramics are similarly low and their mechanical properties are much better than those of the alumina monolith and the zirconia monolith. According to these results, it is predicted that joint prostheses of the composite ceramics are safer against break down and have longer lifetime compared with alumina/alumina joint prostheses.

  13. Dynamic cardiomyoplasty using artificial muscle.

    Science.gov (United States)

    Suzuki, Yasuyuki; Daitoku, Kazuyuki; Minakawa, Masahito; Fukui, Kozo; Fukuda, Ikuo

    2008-01-01

    Dynamic cardiomyoplasty using latissimus dorsi muscle was previously used to compensate for congestive heart failure. Now, however, this method is not acceptable because the long-term result was not as expected owing to fatigue of the skeletal muscle. BioMetal fiber developed by Toki Corporation is one of the artificial muscles activated by electric current. The behavior of this fiber is similar to that of organic muscle. We made an artificial muscle like the latissimus dorsi using BioMetal fiber and tested whether we could use this new muscle as a cardiac supporting device. Testing one Biometal fiber showed the following performance: practical use maximal generative force was 30 g, exercise variation was 50%, and the standard driving current was 220 mA. We created a 4 x 12-cm tabular artificial muscle using 8 BioMetal fibers as a cardiac support device. We also made a simulation circuit composed of a 6 x 8-cm soft bag with unidirectional valves, reservoir, and connecting tube. The simulation circuit was filled with water and the soft bag was wrapped with the artificial muscle device. After powering the device electrically at 9 V with a current of 220 mA for each fiber, we measured the inside pressure and observed the movement of the artificial device. The artificial muscle contracted in 0.5 s for peak time and squeezed the soft bag. The peak pressure inside the soft bag was measured as 10 mmHg. Although further work will be needed to enhance the speed of deformability and movement simulating contraction, we conclude that artificial muscle may be potentially useful as a cardiac assistance device that can be developed for dynamic cardiomyoplasty.

  14. Application Of Artificial Neural Networks In Modeling Of Manufactured Front Metallization Contact Resistance For Silicon Solar Cells

    Directory of Open Access Journals (Sweden)

    Musztyfaga-Staszuk M.

    2015-09-01

    Full Text Available This paper presents the application of artificial neural networks for prediction contact resistance of front metallization for silicon solar cells. The influence of the obtained front electrode features on electrical properties of solar cells was estimated. The front electrode of photovoltaic cells was deposited using screen printing (SP method and next to manufactured by two methods: convectional (1. co-fired in an infrared belt furnace and unconventional (2. Selective Laser Sintering. Resistance of front electrodes solar cells was investigated using Transmission Line Model (TLM. Artificial neural networks were obtained with the use of Statistica Neural Network by Statsoft. Created artificial neural networks makes possible the easy modelling of contact resistance of manufactured front metallization and allows the better selection of production parameters. The following technological recommendations for the screen printing connected with co-firing and selective laser sintering technology such as optimal paste composition, morphology of the silicon substrate, co-firing temperature and the power and scanning speed of the laser beam to manufacture the front electrode of silicon solar cells were experimentally selected in order to obtain uniformly melted structure well adhered to substrate, of a small front electrode substrate joint resistance value. The prediction possibility of contact resistance of manufactured front metallization is valuable for manufacturers and constructors. It allows preserving the customers’ quality requirements and bringing also measurable financial advantages.

  15. Introduction to Concepts in Artificial Neural Networks

    Science.gov (United States)

    Niebur, Dagmar

    1995-01-01

    This introduction to artificial neural networks summarizes some basic concepts of computational neuroscience and the resulting models of artificial neurons. The terminology of biological and artificial neurons, biological and machine learning and neural processing is introduced. The concepts of supervised and unsupervised learning are explained with examples from the power system area. Finally, a taxonomy of different types of neurons and different classes of artificial neural networks is presented.

  16. Artificial organs and transplantation.

    Science.gov (United States)

    Splendiani, G; Cipriani, S; Vega, A; Casciani, C U

    2003-05-01

    Nowadays artificial devices are not able to totally and undefinitely replace the loss of function of all vital organs and artificial organs can be used only to bridge the time to transplantation, which must be considered the first choice in the therapeutical approach for many chronic diseases. Since general population aging process is leading to an increase of organ demand, the gap between performed and requested transplantation is hard to fill. Xenotransplantation is nowadays only an experimental alternative solution and we have to do our best using available artificial organs to increase and improve the survival of patients waiting for transplantation. In this meeting we particularly dealt about organ function replacing therapy, especially regarding the kidney, heart, liver, pancreas and ear.

  17. Artificial senses for characterization of food quality

    Institute of Scientific and Technical Information of China (English)

    HUANG Yan-bo; LAN Yu-bin; R.E. Lacey

    2004-01-01

    Food quality is of primary concern in the food industry and to the consumer. Systems that mimic human senses have been developed and applied to the characterization of food quality. The five primary senses are: vision, hearing, smell, taste and touch.In the characterization of food quality, people assess the samples sensorially and differentiate "good" from "bad" on a continuum.However, the human sensory system is subjective, with mental and physical inconsistencies, and needs time to work. Artificial senses such as machine vision, the electronic ear, electronic nose, electronic tongue, artificial mouth and even artificial the head have been developed that mimic the human senses. These artificial senses are coordinated individually or collectively by a pattern recognition technique, typically artificial neural networks, which have been developed based on studies of the mechanism of the human brain. Such a structure has been used to formulate methods for rapid characterization of food quality. This research presents and discusses individual artificial sensing systems. With the concept of multi-sensor data fusion these sensor systems can work collectively in some way. Two such fused systems, artificial mouth and artificial head, are described and discussed. It indicates that each of the individual systems has their own artificially sensing ability to differentiate food samples. It further indicates that with a more complete mimic of human intelligence the fused systems are more powerful than the individual systems in differentiation of food samples.

  18. Reliability of Tubular Joints

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Thoft-Christensen, Palle

    In this paper the preliminary results obtained by tests on tubular joints are presented. The joints are T-joints and the loading is static. It is the intention in continuation of these tests to perform tests on other types of joints (e.g. Y-joints) and also with dynamic loading. The purpose...... of the test is partly to obtain empirical data for the ultimate load-carrying capacity of tubular T-joints and partly to obtain some experience in performing tests with tubular joints. It is well known that tubular joints are usually designed in offshore engineering on the basis of empirical formulas obtained...... by experimental test results. Therefore, there is a need for performing experimental tests in this area....

  19. Artificial humidification for the mechanically ventilated patient.

    Science.gov (United States)

    Selvaraj, N

    Caring for patients who are mechanically ventilated poses many challenges for critical care nurses. It is important to humidify the patient's airways artificially to prevent complications such as ventilator-associated pneumonia. There is no gold standard to determine which type of humidification is best for patients who are artificially ventilated. This article provides an overview of commonly used artificial humidification for mechanically ventilated patients and discusses nurses' responsibilities in caring for patients receiving artificial humidification.

  20. Impact of Artificial Intelligence on Economic Theory

    OpenAIRE

    Tshilidzi Marwala

    2015-01-01

    Artificial intelligence has impacted many aspects of human life. This paper studies the impact of artificial intelligence on economic theory. In particular we study the impact of artificial intelligence on the theory of bounded rationality, efficient market hypothesis and prospect theory.

  1. An artificial ecosystem model used in the study of social, economic and technological dynamics: An artificial electrical energy market

    International Nuclear Information System (INIS)

    Arjona, D.

    1998-01-01

    This paper will present the artificial ecosystem as a tool, in the development of multi agent models for the simulation of economic and technological dynamics (as well as other possible applications). This tool is based on the mechanics of an artificial society and consists of autonomous artificial agents that interact with individuals that have different characteristics and behavior and other that have a similar conduct to their own. Initial conditions are assumed not to be controllable, however they can be influenced. The importance of the concept of the ecosystem is in understanding great units in the light of their own components which are relevant for the analysis and become interdependent among themselves and with other essential components that hold the total operation of the system. Ideas for the development of a simulation model based on autonomous intelligent agents are presented. These agents will have a brain that is based on artificial intelligence technologies. The Sand Kings Simulation Model, an artificial ecosystem model developed by the author, is described as well as the application of artificial intelligence to this artificial life model. An application to a real life problem is also offered as an artificial energy market that is currently being developed by the author is described

  2. Joint Probability-Based Neuronal Spike Train Classification

    Directory of Open Access Journals (Sweden)

    Yan Chen

    2009-01-01

    Full Text Available Neuronal spike trains are used by the nervous system to encode and transmit information. Euclidean distance-based methods (EDBMs have been applied to quantify the similarity between temporally-discretized spike trains and model responses. In this study, using the same discretization procedure, we developed and applied a joint probability-based method (JPBM to classify individual spike trains of slowly adapting pulmonary stretch receptors (SARs. The activity of individual SARs was recorded in anaesthetized, paralysed adult male rabbits, which were artificially-ventilated at constant rate and one of three different volumes. Two-thirds of the responses to the 600 stimuli presented at each volume were used to construct three response models (one for each stimulus volume consisting of a series of time bins, each with spike probabilities. The remaining one-third of the responses where used as test responses to be classified into one of the three model responses. This was done by computing the joint probability of observing the same series of events (spikes or no spikes, dictated by the test response in a given model and determining which probability of the three was highest. The JPBM generally produced better classification accuracy than the EDBM, and both performed well above chance. Both methods were similarly affected by variations in discretization parameters, response epoch duration, and two different response alignment strategies. Increasing bin widths increased classification accuracy, which also improved with increased observation time, but primarily during periods of increasing lung inflation. Thus, the JPBM is a simple and effective method performing spike train classification.

  3. The functional relationship between the craniomandibular system, cervical spine, and the sacroiliac joint: a preliminary investigation.

    Science.gov (United States)

    Fink, Matthias; Wähling, Knut; Stiesch-Scholz, Meike; Tschernitschek, Harald

    2003-07-01

    The hypothesis of a functional coupling between the muscles of the craniomandibular system and the muscles of other body areas is still controversial. The purpose of this pilot study was to examine whether there is a relationship between the craniomandibular system, the craniocervical system and the sacropelvic region. To test this hypothesis, the prevalence and localization of dysfunction of the cervical spine and the sacroiliac joint were examined in a prospective, experimental trial. Twenty healthy students underwent an artificial occlusal interference, which caused an occlusal interference. The upper cervical spine (CO-C3) and the sacroiliac joint were examined before, during and after this experimental test. The primary outcome with these experimental conditions was the occurrence of hypomobile functional abnormalities. In the presence of occlusal interference, functional abnormalities were detected in both regions examined and these changes were statistically significant. The clinical implications of these findings may be that a complementary examination of these areas in CMD patients could be useful.

  4. What Is an Artificial Muscle? A Systemic Approach.

    OpenAIRE

    Bertrand Tondu

    2015-01-01

    Artificial muscles define a large category of actuators we propose to analyze in a systemic framework by considering any artificial muscle as an open-loop stable system for any output which represents an artificial muscle dimension resulting from its “contraction”, understood in a broad meaning. This approach makes it possible to distinguish the artificial muscle from other actuators and to specify an original model for a linear artificial muscle, according to the theory of linear systems. Su...

  5. Artificial neural network modeling studies to predict the friction welding process parameters of Incoloy 800H joints

    Directory of Open Access Journals (Sweden)

    K. Anand

    2015-09-01

    Full Text Available The present study focuses on friction welding process parameter optimization using a hybrid technique of ANN and different optimization algorithms. This optimization techniques are not only for the effective process modelling, but also to illustrate the correlation between the input and output responses of the friction welding of Incoloy 800H. In addition the focus is also to obtain optimal strength and hardness of joints with minimum burn off length. ANN based approaches could model this welding process of INCOLOY 800H in both forward and reverse directions efficiently, which are required for the automation of the same. Five different training algorithms were used to train ANN for both forward and reverse mapping and ANN tuned force approach was used for optimization. The paper makes a robust comparison of the performances of the five algorithms employing standard statistical indices. The results showed that GANN with 4-9-3 for forward and 4-7-3 for reverse mapping arrangement could outperform the other four approaches in most of the cases but not in all. Experiments on tensile strength (TS, microhardness (H and burn off length (BOL of the joints were performed with optimised parameter. It is concluded that this ANN model with genetic algorithm may provide good ability to predict the friction welding process parameters to weld Incoloy 800H.

  6. Tribological comparison of materials

    Science.gov (United States)

    Shi, Bing

    Approximately 600,000 total joint replacement surgeries are performed each year in the United States. Current artificial joint implants are mainly metal-on-plastic. The synthetic biomaterials undergo degradation through fatigue and corrosive wear from load-bearing and the aqueous ionic environment of the human body. Deposits of inorganic salts can scratch weight-bearing surfaces, making artificial joints stiff and awkward. The excessive wear debris from polyethylene leads to osteolysis and potential loosening of the prosthesis. The lifetime for well-designed artificial joints is at most 10 to 15 years. A patient can usually have two total joint replacements during her/his lifetime. Durability is limited by the body's reaction to wear debris of the artificial joints. Wear of the artificial joints should be reduced. A focus of this thesis is the tribological performance of bearing materials for Total Replacement Artificial Joints (TRAJ). An additional focus is the scaffolds for cell growth from both a tissue engineering and tribological perspective. The tribological properties of materials including Diamond-like Carbon (DLC) coated materials were tested for TRAJ implants. The DLC coatings are chemically inert, impervious to acid and saline media, and are mechanically hard. Carbon-based materials are highly biocompatible. A new alternative to total joints implantation is tissue engineering. Tissue engineering is the replacement of living tissue with tissue that is designed and constructed to meet the needs of the individual patient. Cells were cultured onto the artificial materials, including metals, ceramics, and polymers, and the frictional properties of these materials were investigated to develop a synthetic alternative to orthopedic transplants. Results showed that DLC coated materials had low friction and wear, which are desirable tribological properties for artificial joint material. Cells grew on some of the artificial matrix materials, depending on the

  7. Reinforcement Learning Based Artificial Immune Classifier

    Directory of Open Access Journals (Sweden)

    Mehmet Karakose

    2013-01-01

    Full Text Available One of the widely used methods for classification that is a decision-making process is artificial immune systems. Artificial immune systems based on natural immunity system can be successfully applied for classification, optimization, recognition, and learning in real-world problems. In this study, a reinforcement learning based artificial immune classifier is proposed as a new approach. This approach uses reinforcement learning to find better antibody with immune operators. The proposed new approach has many contributions according to other methods in the literature such as effectiveness, less memory cell, high accuracy, speed, and data adaptability. The performance of the proposed approach is demonstrated by simulation and experimental results using real data in Matlab and FPGA. Some benchmark data and remote image data are used for experimental results. The comparative results with supervised/unsupervised based artificial immune system, negative selection classifier, and resource limited artificial immune classifier are given to demonstrate the effectiveness of the proposed new method.

  8. Artificial intelligence in nanotechnology.

    Science.gov (United States)

    Sacha, G M; Varona, P

    2013-11-15

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines.

  9. Artificial intelligence in nanotechnology

    Science.gov (United States)

    Sacha, G. M.; Varona, P.

    2013-11-01

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines.

  10. Artificial intelligence in nanotechnology

    International Nuclear Information System (INIS)

    Sacha, G M; Varona, P

    2013-01-01

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines. (topical review)

  11. Artificial Intelligence--Applications in Education.

    Science.gov (United States)

    Poirot, James L.; Norris, Cathleen A.

    1987-01-01

    This first in a projected series of five articles discusses artificial intelligence and its impact on education. Highlights include the history of artificial intelligence and the impact of microcomputers; learning processes; human factors and interfaces; computer assisted instruction and intelligent tutoring systems; logic programing; and expert…

  12. Artificial intelligence in medicine.

    OpenAIRE

    Ramesh, A. N.; Kambhampati, C.; Monson, J. R. T.; Drew, P. J.

    2004-01-01

    INTRODUCTION: Artificial intelligence is a branch of computer science capable of analysing complex medical data. Their potential to exploit meaningful relationship with in a data set can be used in the diagnosis, treatment and predicting outcome in many clinical scenarios. METHODS: Medline and internet searches were carried out using the keywords 'artificial intelligence' and 'neural networks (computer)'. Further references were obtained by cross-referencing from key articles. An overview of ...

  13. Artificial intelligence in cardiology

    OpenAIRE

    Bonderman, Diana

    2017-01-01

    Summary Decision-making is complex in modern medicine and should ideally be based on available data, structured knowledge and proper interpretation in the context of an individual patient. Automated algorithms, also termed artificial intelligence that are able to extract meaningful patterns from data collections and build decisions upon identified patterns may be useful assistants in clinical decision-making processes. In this article, artificial intelligence-based studies in clinical cardiol...

  14. Intelligence: Real or artificial?

    OpenAIRE

    Schlinger, Henry D.

    1992-01-01

    Throughout the history of the artificial intelligence movement, researchers have strived to create computers that could simulate general human intelligence. This paper argues that workers in artificial intelligence have failed to achieve this goal because they adopted the wrong model of human behavior and intelligence, namely a cognitive essentialist model with origins in the traditional philosophies of natural intelligence. An analysis of the word “intelligence” suggests that it originally r...

  15. Artificial intelligence: A joint narrative on potential use in pediatric stem and immune cell therapies and regenerative medicine.

    Science.gov (United States)

    Sniecinski, Irena; Seghatchian, Jerard

    2018-05-09

    Artificial Intelligence (AI) reflects the intelligence exhibited by machines and software. It is a highly desirable academic field of many current fields of studies. Leading AI researchers describe the field as "the study and design of intelligent agents". McCarthy invented this term in 1955 and defined it as "the science and engineering of making intelligent machines". The central goals of AI research are reasoning, knowledge, planning, learning, natural language processing (communication), perception and the ability to move and manipulate objects. In fact the multidisplinary AI field is considered to be rather interdisciplinary covering numerous number of sciences and professions, including computer science, psychology, linguistics, philosophy and neurosciences. The field was founded on the claim that a central intellectual property of humans, intelligence-the sapience of Homo Sapiens "can be so precisely described that a machine can be made to simulate it". This raises philosophical issues about the nature of the mind and the ethics of creating artificial beings endowed with human-like intelligence. Artificial Intelligence has been the subject of tremendous optimism but has also suffered stunning setbacks. The goal of this narrative is to review the potential use of AI approaches and their integration into pediatric cellular therapies and regenerative medicine. Emphasis is placed on recognition and application of AI techniques in the development of predictive models for personalized treatments with engineered stem cells, immune cells and regenerated tissues in adults and children. These intelligent machines could dissect the whole genome and isolate the immune particularities of individual patient's disease in a matter of minutes and create the treatment that is customized to patient's genetic specificity and immune system capability. AI techniques could be used for optimization of clinical trials of innovative stem cell and gene therapies in pediatric patients

  16. The artificial neural networks: An approach to artificial intelligence; Un approccio ``biologico`` all`intelligenza artificiale

    Energy Technology Data Exchange (ETDEWEB)

    Taraglio, Sergio; Zanela, Andrea [ENEA, Casaccia (Italy). Dipt. Innovazione

    1997-05-01

    The artificial neural networks try to simulate the functionalities of the nervous system through a complex network of simple computing elements. In this work is presented an introduction to the neural networks and some of their possible applications, especially in the field of Artificial Intelligence.

  17. Ethical Considerations in Artificial Intelligence Courses

    OpenAIRE

    Burton, Emanuelle; Goldsmith, Judy; Koenig, Sven; Kuipers, Benjamin; Mattei, Nicholas; Walsh, Toby

    2017-01-01

    The recent surge in interest in ethics in artificial intelligence may leave many educators wondering how to address moral, ethical, and philosophical issues in their AI courses. As instructors we want to develop curriculum that not only prepares students to be artificial intelligence practitioners, but also to understand the moral, ethical, and philosophical impacts that artificial intelligence will have on society. In this article we provide practical case studies and links to resources for ...

  18. Clonación artificial de controladores basados en técnicas de inteligencia artificial

    Directory of Open Access Journals (Sweden)

    Javier Antonio Ballesteros

    2004-11-01

    Full Text Available En el presente articulo se expone un avance de anteproyecto, sobre técnicas de inteligencia Artificial, su aplicación a procesos industriales y herramientas para realizar simulación. Se citan algunos trabajos en los cuales hay resultados, y que prestan un soporte lógico para continuar con el desarrollo del proyecto. Ademas, se analiza, la función que cumple el controlador el cual debe ser preciso, confiable y que a su vez reduzca costos. Por estas razones se tomó como base del proyecto un controlador que posea estas características para que se puedan aplicar técnicas de lnteligencia Artificial y poder realizar Ia colación artificial.

  19. Artificial Reefs

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — An artificial reef is a human-made underwater structure, typically built to promote marine life in areas with a generally featureless bottom, control erosion, block...

  20. Engineering a Light-Attenuating Artificial Iris

    Science.gov (United States)

    Shareef, Farah J.; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-01-01

    Purpose Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. Methods The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Results Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Conclusions Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage. PMID:27116547

  1. Engineering a Light-Attenuating Artificial Iris.

    Science.gov (United States)

    Shareef, Farah J; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-04-01

    Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage.

  2. The principles of artificial neural network information processing

    International Nuclear Information System (INIS)

    Dai, Ru-Wei

    1993-01-01

    In this article, the basic structure of an artificial neuron is first introduced. In addition, principles of artificial neural network as well as several important artificial neural models such as Perceptron, Back propagation model, Hopfield net, and ART model are briefly discussed and analyzed. Finally, the application of artificial neural network for Chinese Character Recognition is also given. (author)

  3. The principles of artificial neural network information processing

    International Nuclear Information System (INIS)

    Dai, Ru-Wei

    1993-01-01

    In this article, the basic structure of an artificial neuron is first introduced. In addition, principles of artificial neural network as well as several important artificial neural models such as perception, back propagation model, Hopfield net, and ART model are briefly discussed and analyzed. Finally the application of artificial neural network for Chinese character recognition is also given. (author)

  4. Artificial organs 2011: a year in review.

    Science.gov (United States)

    Malchesky, Paul S

    2012-03-01

    In this Editor's Review, articles published in 2011 are organized by category and briefly summarized. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, and the International Society for Rotary Blood Pumps, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level."Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ replacement, recovery, and regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers, the quality expected from such a journal would not be possible. We also express our special thanks to our Publisher, Wiley-Blackwell, for their expert attention and support in the production and marketing of Artificial Organs. In this Editor's Review, that historically has been widely well-received by our readership, we aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ replacement, recovery, and regeneration. We look forward to recording further advances in the coming years. © 2012, Copyright the Author. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Artificial Organs 2012: a year in review.

    Science.gov (United States)

    Malchesky, Paul S

    2013-03-01

    In this editor's review, articles published in 2012 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ replacement, recovery, and regeneration. As the official journal of the International Federation for Artificial Organs, the International Faculty for Artificial Organs, and the International Society for Rotary Blood Pumps, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ replacement, recovery, and regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide such meaningful suggestions to the author's work whether eventually accepted or rejected, and especially to those whose native tongue is not English. Without these excellent and dedicated reviewers, the quality expected from such a journal could not be possible. We also express our special thanks to our publisher, Wiley Periodicals, for their expert attention and support in the production and marketing of Artificial Organs. We look forward to recording further advances in the coming years. © 2013, Copyright the Author. Artificial Organs © 2013, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Does generalized joint hypermobility predict joint injury in sport? A review.

    LENUS (Irish Health Repository)

    Donaldson, Peter R

    2012-02-01

    OBJECTIVE: To determine whether persons with generalized joint hypermobility have an increased risk of lower limb joint injury during sport. DATA SOURCES: PubMed, CINAHL, EMBASE, and SportDiscus were searched through February 2009, without language restrictions, using terms related to risk; hip, ankle, and knee injuries; and joint instability. Reference lists of included studies and relevant reviews were searched by hand. STUDY SELECTION: Selection criteria were peer-reviewed studies with a prospective design that used an objective scale to measure generalized joint hypermobility; the participants were engaged in sport activity, and the injury data were quantitative and based on diagnosis by a health professional, were self-reported, or resulted in time lost to athletic participation. The studies were screened by 1 researcher and checked by a second. Study methods were independently assessed by 2 investigators using the 6-point scale for prognostic studies developed by Pengel. Disagreements were resolved through discussion. Of 4841 studies identified, 18 met inclusion criteria. Of these, 8 were included in random-effects meta-analyses. DATA EXTRACTION: The data extracted by 2 reviewers included participant and sport characteristics and details of joint hypermobility and injury measurements. More detailed data for 4 investigations were obtained from the study authors. Where possible, hypermobility was defined as >\\/=4 of 9 points on the British Society of Rheumatology Scale (BSRS). MAIN RESULTS: Lower limb joint injuries (3 studies, 1047 participants) occurred in 14% of participants. Using the BSRS of joint hypermobility, any lower limb injury was not associated with hypermobility [odds ratio (OR), 1.43; 95% confidence interval (CI), 0.56-3.67]. Using the original authors\\' definitions, hypermobility was associated with risk of knee joint injuries (OR, 2.62; 95% CI, 1.04-6.58) in 5 studies. In 4 studies in which the BSRS could be used (1167 participants; incidence

  7. Sucrose compared with artificial sweeteners

    DEFF Research Database (Denmark)

    Sørensen, Lone Brinkmann; Vasilaras, Tatjana H; Astrup, Arne

    2014-01-01

    There is a lack of appetite studies in free-living subjects supplying the habitual diet with either sucrose or artificially sweetened beverages and foods. Furthermore, the focus of artificial sweeteners has only been on the energy intake (EI) side of the energy-balance equation. The data are from...

  8. Radiation induced change in the affinity of a plastic resin to chlorine contained in artificial tap water

    International Nuclear Information System (INIS)

    Fujiyoshi, Ryoko; Sawamura, Sadashi; Katayama, Meiseki

    1985-01-01

    γ-Radiation curing of a polyacetal resin was attempted in order to eliminate the unsuitable property for the joints of tap water pipes. In the case of non-irradiated resin, almost all available chlorine (AC) contained in usual tap water disappeared. γ-Irradiation of the resin showed an indirect effect on eliminating such a property; that is, a decrease in the amount of AC from artificial tap water (test solution) showed a decrease to JIS (Japan Industrial Standards) level of requirement at certain absorption doses. However, it was also found that the decrease in the amount of AC from the test solution increased with time after γ-irradiation. (author)

  9. A computational model for three-dimensional jointed media with a single joint set

    International Nuclear Information System (INIS)

    Koteras, J.R.

    1994-02-01

    This report describes a three-dimensional model for jointed rock or other media with a single set of joints. The joint set consists of evenly spaced joint planes. The normal joint response is nonlinear elastic and is based on a rational polynomial. Joint shear stress is treated as being linear elastic in the shear stress versus slip displacement before attaining a critical stress level governed by a Mohr-Coulomb faction criterion. The three-dimensional model represents an extension of a two-dimensional, multi-joint model that has been in use for several years. Although most of the concepts in the two-dimensional model translate in a straightforward manner to three dimensions, the concept of slip on the joint planes becomes more complex in three dimensions. While slip in two dimensions can be treated as a scalar quantity, it must be treated as a vector in the joint plane in three dimensions. For the three-dimensional model proposed here, the slip direction is assumed to be the direction of maximum principal strain in the joint plane. Five test problems are presented to verify the correctness of the computational implementation of the model

  10. The joint flanker effect and the joint Simon effect: On the comparability of processes underlying joint compatibility effects.

    Science.gov (United States)

    Dittrich, Kerstin; Bossert, Marie-Luise; Rothe-Wulf, Annelie; Klauer, Karl Christoph

    2017-09-01

    Previous studies observed compatibility effects in different interference paradigms such as the Simon and flanker task even when the task was distributed across two co-actors. In both Simon and flanker tasks, performance is improved in compatible trials relative to incompatible trials if one actor works on the task alone as well as if two co-actors share the task. These findings have been taken to indicate that actors automatically co-represent their co-actor's task. However, recent research on the joint Simon and joint flanker effect suggests alternative non-social interpretations. To which degree both joint effects are driven by the same underlying processes is the question of the present study, and it was scrutinized by manipulating the visibility of the co-actor. While the joint Simon effect was not affected by the visibility of the co-actor, the joint flanker effect was reduced when participants did not see their co-actors but knew where the co-actors were seated. These findings provide further evidence for a spatial interpretation of the joint Simon effect. In contrast to recent claims, however, we propose a new explanation of the joint flanker effect that attributes the effect to an impairment in the focusing of spatial attention contingent on the visibility of the co-actor.

  11. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    Science.gov (United States)

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  12. Bioengineering of Artificial Lymphoid Organs.

    Science.gov (United States)

    Nosenko, M A; Drutskaya, M S; Moisenovich, M M; Nedospasov, S A

    2016-01-01

    This review addresses the issue of bioengineering of artificial lymphoid organs.Progress in this field may help to better understand the nature of the structure-function relations that exist in immune organs. Artifical lymphoid organs may also be advantageous in the therapy or correction of immunodefficiencies, autoimmune diseases, and cancer. The structural organization, development, and function of lymphoid tissue are analyzed with a focus on the role of intercellular contacts and on the cytokine signaling pathways regulating these processes. We describe various polymeric materials, as scaffolds, for artificial tissue engineering. Finally, published studies in which artificial lymphoid organs were generated are reviewed and possible future directions in the field are discussed.

  13. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    Science.gov (United States)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  14. Artificial Immune Networks: Models and Applications

    Directory of Open Access Journals (Sweden)

    Xian Shen

    2008-06-01

    Full Text Available Artificial Immune Systems (AIS, which is inspired by the nature immune system, has been applied for solving complex computational problems in classification, pattern rec- ognition, and optimization. In this paper, the theory of the natural immune system is first briefly introduced. Next, we compare some well-known AIS and their applications. Several representative artificial immune networks models are also dis- cussed. Moreover, we demonstrate the applications of artificial immune networks in various engineering fields.

  15. The Past, Present, and Future of Artificial Life

    Directory of Open Access Journals (Sweden)

    Wendy eAguilar

    2014-10-01

    Full Text Available For millennia people have wondered what makes the living different from the non-living. Beginning in the mid-1980s, artificial life has studied living systems using a synthetic approach: build life in order to understand it better, be it by means of software, hardware, or wetware. This review provides a summary of the advances that led to the development of artificial life, its current research topics, and open problems and opportunities. We classify artificial life research into fourteen themes: origins of life, autonomy, self-organization, adaptation (including evolution, development, and learning, ecology, artificial societies, behavior, computational biology, artificial chemistries, information, living technology, art, and philosophy. Being interdisciplinary, artificial life seems to be losing its boundaries and merging with other fields.

  16. Joint ventures

    DEFF Research Database (Denmark)

    Sørensen, Karsten Engsig

    Afhandlingen analysere de konkurrenceretlige og selskabsretlige regler som er bestemmende for hvordan et joint venture samarbejde er struktureret......Afhandlingen analysere de konkurrenceretlige og selskabsretlige regler som er bestemmende for hvordan et joint venture samarbejde er struktureret...

  17. A DISTRIBUTED SMART HOME ARTIFICIAL INTELLIGENCE SYSTEM

    DEFF Research Database (Denmark)

    Lynggaard, Per

    2013-01-01

    A majority of the research performed today explore artificial intelligence in smart homes by using a centralized approach where a smart home server performs the necessary calculations. This approach has some disadvantages that can be overcome by shifting focus to a distributed approach where...... the artificial intelligence system is implemented as distributed as agents running parts of the artificial intelligence system. This paper presents a distributed smart home architecture that distributes artificial intelligence in smart homes and discusses the pros and cons of such a concept. The presented...... distributed model is a layered model. Each layer offers a different complexity level of the embedded distributed artificial intelligence. At the lowest layer smart objects exists, they are small cheap embedded microcontroller based smart devices that are powered by batteries. The next layer contains a more...

  18. Artificial organs 2010: a year in review.

    Science.gov (United States)

    Malchesky, Paul S

    2011-03-01

    In this Editor's Review, articles published in 2010 are organized by category and briefly summarized. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, and the International Society for Rotary Blood Pumps, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level."Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide such meaningful suggestions to the author's work whether eventually accepted or rejected and especially to those whose native tongue is not English. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, Wiley-Blackwell, for their expert attention and support in the production and marketing of Artificial Organs. In this Editor's Review, that historically has been widely received by our readership, we aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. We look forward to recording further advances in the coming years. © 2011, Copyright the Author. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. A New Method for Determination of Joint Roughness Coefficient of Rock Joints

    Directory of Open Access Journals (Sweden)

    Shigui Du

    2015-01-01

    Full Text Available The joint roughness coefficient (JRC of rock joints has the characteristic of scale effect. JRC measured on small-size exposed rock joints should be evaluated by JRC scale effect in order to obtain the JRC of actual-scale rock joints, since field rock joints are hardly fully exposed or well saved. Based on the validity analysis of JRC scale effect, concepts of rate of JRC scale effect and effective length of JRC scale effect were proposed. Then, a graphic method for determination of the effective length of JRC scale effect was established. Study results show that the JRC of actual-scale rock joints can be obtained through a fractal model of JRC scale effect according to the statistically measured results of the JRC of small-size partial exposed rock joints and by the selection of fractal dimension of JRC scale effect and the determination of effective length of JRC scale effect.

  20. Level-Ground Walking for 3D Quasi-Passive Walker with Flat Feet - Lateral-plane Input using McKibben-Type Artificial Muscle -

    Directory of Open Access Journals (Sweden)

    Yamamoto Akihiro

    2016-01-01

    Full Text Available Currently, many bipedal robots have been proposed to realize the high energy efficiency walking. The passive dynamic walking does not require control input. Generally, a foot of passive dynamic walking robot is an arc foot. In this paper, it is intended to establish a control method and control mechanism to achieve energy efficient and stable gate. Therefore, we developed 3D quasi-passive walker with flat feet driven by an antagonistic pneumatic artificial muscle. An antagonistic mechanism is constituted by a pair of McKibben muscle. And an antagonistic pneumatic system is used as joint actuators of linkage mechanisms which control the torque, joint stiffness and position simultaneously. Finally, this report shows that the 3D quasi-passive walking in the level ground can realize by the swinging (simple input of the frontal direction, and the stride of the robot is proportional to lateral-plane input.

  1. Artificial Intelligence and Its Importance in Education.

    Science.gov (United States)

    Tilmann, Martha J.

    Artificial intelligence, or the study of ideas that enable computers to be intelligent, is discussed in terms of what it is, what it has done, what it can do, and how it may affect the teaching of tomorrow. An extensive overview of artificial intelligence examines its goals and applications and types of artificial intelligence including (1) expert…

  2. Minimally Naturalistic Artificial Intelligence

    OpenAIRE

    Hansen, Steven Stenberg

    2017-01-01

    The rapid advancement of machine learning techniques has re-energized research into general artificial intelligence. While the idea of domain-agnostic meta-learning is appealing, this emerging field must come to terms with its relationship to human cognition and the statistics and structure of the tasks humans perform. The position of this article is that only by aligning our agents' abilities and environments with those of humans do we stand a chance at developing general artificial intellig...

  3. Artificial Muscles: Mechanisms, Applications, and Challenges.

    Science.gov (United States)

    Mirvakili, Seyed M; Hunter, Ian W

    2018-02-01

    The area of artificial muscle is a highly interdisciplinary field of research that has evolved rapidly in the last 30 years. Recent advances in nanomaterial fabrication and characterization, specifically carbon nanotubes and nanowires, have had major contributions in the development of artificial muscles. However, what can artificial muscles really do for humans? This question is considered here by first examining nature's solutions to this design problem and then discussing the structure, actuation mechanism, applications, and limitations of recently developed artificial muscles, including highly oriented semicrystalline polymer fibers; nanocomposite actuators; twisted nanofiber yarns; thermally activated shape-memory alloys; ionic-polymer/metal composites; dielectric-elastomer actuators; conducting polymers; stimuli-responsive gels; piezoelectric, electrostrictive, magnetostrictive, and photostrictive actuators; photoexcited actuators; electrostatic actuators; and pneumatic actuators. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. 7 CFR 51.2542 - U.S. Artificially Opened.

    Science.gov (United States)

    2010-01-01

    ... STANDARDS) United States Standards for Grades of Pistachio Nuts in the Shell § 51.2542 U.S. Artificially Opened. “U.S. Artificially Opened” consists of artificially opened pistachio nuts in the shell which meet...

  5. Laboratory characterization of rock joints

    International Nuclear Information System (INIS)

    Hsiung, S.M.; Kana, D.D.; Ahola, M.P.; Chowdhury, A.H.; Ghosh, A.

    1994-05-01

    A laboratory characterization of the Apache Leap tuff joints under cyclic pseudostatic and dynamic loads has been undertaken to obtain a better understanding of dynamic joint shear behavior and to generate a complete data set that can be used for validation of existing rock-joint models. Study has indicated that available methods for determining joint roughness coefficient (JRC) significantly underestimate the roughness coefficient of the Apache Leap tuff joints, that will lead to an underestimation of the joint shear strength. The results of the direct shear tests have indicated that both under cyclic pseudostatic and dynamic loadings the joint resistance upon reverse shearing is smaller than that of forward shearing and the joint dilation resulting from forward shearing recovers during reverse shearing. Within the range of variation of shearing velocity used in these tests, the shearing velocity effect on rock-joint behavior seems to be minor, and no noticeable effect on the peak joint shear strength and the joint shear strength for the reverse shearing is observed

  6. Bayesian artificial intelligence

    CERN Document Server

    Korb, Kevin B

    2003-01-01

    As the power of Bayesian techniques has become more fully realized, the field of artificial intelligence has embraced Bayesian methodology and integrated it to the point where an introduction to Bayesian techniques is now a core course in many computer science programs. Unlike other books on the subject, Bayesian Artificial Intelligence keeps mathematical detail to a minimum and covers a broad range of topics. The authors integrate all of Bayesian net technology and learning Bayesian net technology and apply them both to knowledge engineering. They emphasize understanding and intuition but also provide the algorithms and technical background needed for applications. Software, exercises, and solutions are available on the authors' website.

  7. THE RELATIONSHIP BETWEEN TEMPOROMANDIBULAR-JOINT MOBILITY AND PERIPHERAL JOINT MOBILITY RECONSIDERED

    NARCIS (Netherlands)

    Dijkstra, P.U.; DEBONT, L.G.M.; VANDERWEELE, L.T.; Boering, G.

    The purpose of this paper was to study the relationship between temporomandibular joint (TMJ) mobility and mobility of joints and to study the general character of joint mobility in 83 subjects, 55 females and 28 males (mean age 26.7, range 13-46 years). The subjects were recruited from the

  8. Dual joint space arthrography in temporomandibular joint disorders: Comparison with single inferior joint space arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Sik; Chang, Duk Soo; Lee, Kyung Soo; Kim, Woo Sun; Sung, Jung Ho; Jun, Young Hwan [Capital Armed Forces General Hospital, Seoul (Korea, Republic of)

    1989-02-15

    The temporomandibular joint(TMJ) is really a complex of two synovial space separated by fibrocartilaginous disc. Single inferior joint space arthrography is commonly performed for evaluation of TMJ disorders, which is known to be superior in demonstrating joint dynamics. But it reveals only the inferior surface of the disc. Therefore, dual space arthrography is superior to demonstrate the soft tissue anatomic feature of the joint such as disc position and shape. Authors performed 83 TMJ arthrograms in TMJ problems. Initially, the inferior joint space was done and then the superior space was sequentially contrasted. The follow results were noted: 1. In all cases, dual space arthrography revealed accurate disc shape and positions. 2. Concordant findings between the two techniques: 68 cases (82%). Discordance between the two techniques: 15 cases (18%) 3. Possible causes of discordance between inferior and dual space arthrography. a) Normal varians of anterior recess: 3 cases b) Posterior disc displacement: 4 cases c) Influence of the patient's head position change :4 cases d) False perforation: 2 cases e) Reduction change: 2 cases 4. In 5 cases with anterior displacement, dual space arthrography gave additional findings such as adhesion within the superior space, which could not be evaluated by single inferior space.

  9. Artificial intelligence in power system optimization

    CERN Document Server

    Ongsakul, Weerakorn

    2013-01-01

    With the considerable increase of AI applications, AI is being increasingly used to solve optimization problems in engineering. In the past two decades, the applications of artificial intelligence in power systems have attracted much research. This book covers the current level of applications of artificial intelligence to the optimization problems in power systems. This book serves as a textbook for graduate students in electric power system management and is also be useful for those who are interested in using artificial intelligence in power system optimization.

  10. Effects of changes in skiing posture on the kinetics of the knee joint.

    Science.gov (United States)

    Koyanagi, Maki; Shino, Konsei; Yoshimoto, Yoji; Inoue, Satoru; Sato, Mutsumi; Nakata, Ken

    2006-01-01

    This study was performed to investigate the effects of changes in the skiing posture on mechanical stress across the knee joint. The aim of the present study was to establish a safer form of skiing for the prevention of injury to the anterior cruciate ligament of the knee (ACL). Ten healthy volunteers were placed on a force plate on an artificial slope, and assumed forward and backward bending postures with a single leg by changing their centre of gravity. The knee flexion angles were limited to approximately 30 degrees by orthotics in each posture. Joint moments of the lower extremity were analyzed using a motion analysis system, and the muscle activities of the lower extremity were recorded by EMG and digitised to integrated EMG in each posture. In addition, extrusion of the lower leg by the boot was measured using a force sensor sheet inserted behind the calf. We found that the extension moment of the hip and ankle joints, and muscular activity of the hamstrings were increased in forward bending, whereas the extension moment of the knee and muscular activity of the quadriceps were decreased. Conversely, the muscular activity of the quadriceps, the flexion moment of the hip, extension moment of the knee joint, and pressure of the boot were increased in backward bending, whereas muscular activity of the hamstrings was decreased. The dependency on the hamstrings increased in forward bending in a skiing posture on a slope with slight knee flexion. Therefore, forward bending seemed to be an advantageous posture for the prevention of ACL injury. Conversely, in a backward bending skiing posture, the extension moment of the knee joint produced by muscle contraction of the quadriceps also increased imbalance in the hamstrings. The results of this study suggest that the internal force exerted by the quadriceps, in addition to the passive factor of extrusion of the lower leg by the boot, may contribute to non-contact ACL injury in a backward bending posture while skiing.

  11. Joint Electromagnetic Spectrum Management Operations

    Science.gov (United States)

    2012-03-20

    promulgate command-specific policy and guidance for EMS use, the joint restricted frequency list (JRFL) process, the joint communications–electronics...joint communications–electronics operating instructions (JCEOI) and joint restricted frequency list (JRFL). Examples of FM include providing the...joint restricted frequency list Figure III-4. Joint Frequency Management Office Spectrum Management Process Chapter III III-10 JP 6-01 assignments

  12. Embodied artificial agents for understanding human social cognition.

    Science.gov (United States)

    Wykowska, Agnieszka; Chaminade, Thierry; Cheng, Gordon

    2016-05-05

    In this paper, we propose that experimental protocols involving artificial agents, in particular the embodied humanoid robots, provide insightful information regarding social cognitive mechanisms in the human brain. Using artificial agents allows for manipulation and control of various parameters of behaviour, appearance and expressiveness in one of the interaction partners (the artificial agent), and for examining effect of these parameters on the other interaction partner (the human). At the same time, using artificial agents means introducing the presence of artificial, yet human-like, systems into the human social sphere. This allows for testing in a controlled, but ecologically valid, manner human fundamental mechanisms of social cognition both at the behavioural and at the neural level. This paper will review existing literature that reports studies in which artificial embodied agents have been used to study social cognition and will address the question of whether various mechanisms of social cognition (ranging from lower- to higher-order cognitive processes) are evoked by artificial agents to the same extent as by natural agents, humans in particular. Increasing the understanding of how behavioural and neural mechanisms of social cognition respond to artificial anthropomorphic agents provides empirical answers to the conundrum 'What is a social agent?' © 2016 The Authors.

  13. Cervical Spine Involvement as Initial Manifestation of Rheumatoid Arthritis: a case report

    Directory of Open Access Journals (Sweden)

    Filipe Araújo

    2015-01-01

    Full Text Available Rheumatoid arthritis’ synovitis affects mostly small hand and feet joints, although it may compromise any joint with a synovial lining. Cervical involvement occurs usually in longstanding disease in over half of these patients. We report the case of a 35-year old male patient who was referred to our outpatient clinic for a 2-year severe and disabling inflammatory neck pain, with incomplete response to intramuscular non-steroidal anti-inflammatory drugs and unremarkable cervical imaging studies. He also mentioned self-limited episodes of symmetric polyarthralgia involving hands, wrists, elbows, knees and feet, which started after his cervical complaints. On laboratorial workup, positive rheumatoid factor and anti-citrullinated peptide antibody and negative HLA-B27 were found. Cervical spine magnetic resonance imaging revealed atlantoaxial subluxation and odontoid process inflammatory pannus and erosions. Rheumatoid arthritis with cervical spine involvement as initial manifestation of disease was the definite diagnosis. The patient was started on methotrexate and prednisone and he was referred to neurosurgery outpatient clinic for cervical spine fixation.

  14. Joint diseases

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    The authors discuss how x-ray examination is essential in the diagnosis and evaluation of the arthritides. Most arthritides are first suspected by the clinician, and x-ray evaluation of these entities along with laboratory testing is important for confirmation of the clinical diagnosis and in staging of the disease process. Several arthritides are often diagnosed first by the podiatrist on x-ray evaluation, including pseudogout, ankylosing spondylitis, early rheumatoid arthritis, degenerative joint disease, and tuberculosis of bone. The joint responds to insult in only a limited number of ways that become apparent on x-ray. The soft tissues surrounding the joint, the articulating bones, and alignment of the joint space may all be involved by the arthritic process. On roentgenographic examination, the soft tissues must be examined for edema, masses, calcifications, and atrophy. The articulating bones must be examined for demineralization, erosions, osteophytes, periosteal reaction, cysts and sclerosis

  15. Principles of artificial intelligence

    CERN Document Server

    Nilsson, Nils J

    1980-01-01

    A classic introduction to artificial intelligence intended to bridge the gap between theory and practice, Principles of Artificial Intelligence describes fundamental AI ideas that underlie applications such as natural language processing, automatic programming, robotics, machine vision, automatic theorem proving, and intelligent data retrieval. Rather than focusing on the subject matter of the applications, the book is organized around general computational concepts involving the kinds of data structures used, the types of operations performed on the data structures, and the properties of th

  16. Biological Effects Of Artificial Illumination

    Science.gov (United States)

    Corth, Richard

    1980-10-01

    We are increasingly being warned of the possible effects of so called "polluted" light, that is light that differs in spectral content from that of sunlight. We should be concerned, we are told, because all animals and plants have evolved under this natural daylight and therefore any difference between that illuminant and the artificial illuminants that are on the market today, is suspect. The usual presentation of the differences between the sunlight and the artificial illuminants are as shown in Figure 1. Here we are shown the spectral power distribution of sunlight and Cool White fluorescent light. The spectral power distributions of each have been normalized to some convenient wavelength so that each can be seen and easily compared on the same figure. But this presentation is misleading for one does not experience artificial illuminants at the same intensity as one experiences sunlight. Sunlight intensities are ordinarily found to be in the 8000 to 10,000 footcandle range whereas artificial illuminants are rarely experienced at intensity levels greater than 100 footcandles. Therefore a representative difference between the two types of illumination conditions is more accurately represented as in Figure 2. Thus if evolutionary adaptations require that humans and other animals be exposed to sunlight to ensure wellbeing, it is clear that one must be exposed to sunlight intensities. It is not feasible to expect that artificially illuminated environments will be lit to the same intensity as sunlight

  17. Artificial tears potpourri: a literature review

    Science.gov (United States)

    Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F

    2014-01-01

    Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. PMID:25114502

  18. Artificial Organs 2015: A Year in Review.

    Science.gov (United States)

    Malchesky, Paul S

    2016-03-01

    In this Editor's Review, articles published in 2015 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We take this time also to express our gratitude to our authors for providing their work to this journal. We offer our very special thanks to our reviewers who give so generously of their time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers, the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Artificial Organs 2013: a year in review.

    Science.gov (United States)

    Malchesky, Paul S

    2014-03-01

    In this Editor's Review, articles published in 2013 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level". Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide so meaningful suggestions to the author's work whether eventually accepted or rejected and especially to those whose native tongue is not English. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, Wiley Periodicals, for their expert attention and support in the production and marketing of Artificial Organs. We look forward to recording further advances in the coming years. © 2014 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  20. Imaging findings of charcot joint

    International Nuclear Information System (INIS)

    Meng Quanfei; Zhou Chunxiang; Chen Yingming; Jiang Bo

    2003-01-01

    Objective: To analyze the MRI characters of Charcot joint, and to evaluate the diagnostic value of X-ray, CT, and MRI on Charcot joint. Methods: Eight patients with 8 Charcot joints underwent X-ray, CT, and MR examinations. 6 of them had syringomyelia, 1 patient had injury of the spinal cord, and 1 case had diabetes. All 8 patients had sensory reduction or deficit in the sick extremities. Results: There were two types of Charcot joint, hypertrophic and atrophic. Radiographic and CT features of hypertrophic joint (n=3) showed hyperostotic osteosclerosis and mammoth osteophytes in the sick bones, periarticular ossification, and articular disorganization. Radiographic and CT features of atrophic joint (n=5) showed extensive bone resorption (destruction), periarticular debris, and articular disorganization. Main MRI features of Charcot joint included hydrarthrosis within joint capsule, thickened, loose, and elongated joint capsule with para-joint, peri-diaphysis, and inter-muscular extension in a pseudopodia pattern. The irregular joint capsule wall was presented as mild hypointensity on T 1 WI, slight hyper-intensity on T 2 WI, and was markedly enhanced after Gd-DTPA was administrated, which was considered as a characteristic manifestation of the lesion. Soft tissue mass containing hypo-intense stripes on both T 1 WI and T 2 WI was commonly noted adjacent to the involved joint. Conclusion: X-rays plain film is the first choice for the diagnosis of Charcot joint, and MRI is pretty useful in the diagnosis of Charcot joint

  1. Artificial Intelligence in Cardiology.

    Science.gov (United States)

    Johnson, Kipp W; Torres Soto, Jessica; Glicksberg, Benjamin S; Shameer, Khader; Miotto, Riccardo; Ali, Mohsin; Ashley, Euan; Dudley, Joel T

    2018-06-12

    Artificial intelligence and machine learning are poised to influence nearly every aspect of the human condition, and cardiology is not an exception to this trend. This paper provides a guide for clinicians on relevant aspects of artificial intelligence and machine learning, reviews selected applications of these methods in cardiology to date, and identifies how cardiovascular medicine could incorporate artificial intelligence in the future. In particular, the paper first reviews predictive modeling concepts relevant to cardiology such as feature selection and frequent pitfalls such as improper dichotomization. Second, it discusses common algorithms used in supervised learning and reviews selected applications in cardiology and related disciplines. Third, it describes the advent of deep learning and related methods collectively called unsupervised learning, provides contextual examples both in general medicine and in cardiovascular medicine, and then explains how these methods could be applied to enable precision cardiology and improve patient outcomes. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Transport modeling: An artificial immune system approach

    Directory of Open Access Journals (Sweden)

    Teodorović Dušan

    2006-01-01

    Full Text Available This paper describes an artificial immune system approach (AIS to modeling time-dependent (dynamic, real time transportation phenomenon characterized by uncertainty. The basic idea behind this research is to develop the Artificial Immune System, which generates a set of antibodies (decisions, control actions that altogether can successfully cover a wide range of potential situations. The proposed artificial immune system develops antibodies (the best control strategies for different antigens (different traffic "scenarios". This task is performed using some of the optimization or heuristics techniques. Then a set of antibodies is combined to create Artificial Immune System. The developed Artificial Immune transportation systems are able to generalize, adapt, and learn based on new knowledge and new information. Applications of the systems are considered for airline yield management, the stochastic vehicle routing, and real-time traffic control at the isolated intersection. The preliminary research results are very promising.

  3. Artificial Intelligence for the Artificial Kidney: Pointers to the Future of a Personalized Hemodialysis Therapy.

    Science.gov (United States)

    Hueso, Miguel; Vellido, Alfredo; Montero, Nuria; Barbieri, Carlo; Ramos, Rosa; Angoso, Manuel; Cruzado, Josep Maria; Jonsson, Anders

    2018-02-01

    Current dialysis devices are not able to react when unexpected changes occur during dialysis treatment or to learn about experience for therapy personalization. Furthermore, great efforts are dedicated to develop miniaturized artificial kidneys to achieve a continuous and personalized dialysis therapy, in order to improve the patient's quality of life. These innovative dialysis devices will require a real-time monitoring of equipment alarms, dialysis parameters, and patient-related data to ensure patient safety and to allow instantaneous changes of the dialysis prescription for the assessment of their adequacy. The analysis and evaluation of the resulting large-scale data sets enters the realm of "big data" and will require real-time predictive models. These may come from the fields of machine learning and computational intelligence, both included in artificial intelligence, a branch of engineering involved with the creation of devices that simulate intelligent behavior. The incorporation of artificial intelligence should provide a fully new approach to data analysis, enabling future advances in personalized dialysis therapies. With the purpose to learn about the present and potential future impact on medicine from experts in artificial intelligence and machine learning, a scientific meeting was organized in the Hospital Universitari Bellvitge (L'Hospitalet, Barcelona). As an outcome of that meeting, the aim of this review is to investigate artificial intel ligence experiences on dialysis, with a focus on potential barriers, challenges, and prospects for future applications of these technologies. Artificial intelligence research on dialysis is still in an early stage, and the main challenge relies on interpretability and/or comprehensibility of data models when applied to decision making. Artificial neural networks and medical decision support systems have been used to make predictions about anemia, total body water, or intradialysis hypotension and are promising

  4. ARTIFICIAL AND NATURAL INTELLIGENCE IN ANTHROPOGENIC EDUCATIONAL ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    Sergey F. Sergeev

    2013-01-01

    Full Text Available In the present article we show the link between both artificial and natural intelligence and the system’s complexity during the life-cycle. Autopoetic’s type of living systems determines the differences between natural and artificial intelligence; artificial environments have an influence to the intelligence abilities development. We present the «diffusion intellect» concept where the diffusion intellect is considered as a synergistic unity of natural and artificial intellect in organized environments. 

  5. Computed Flow Through An Artificial Heart And Valve

    Science.gov (United States)

    Rogers, Stuart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    NASA technical memorandum discusses computations of flow of blood through artificial heart and through tilting-disk artificial heart valve. Represents further progress in research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478). One purpose of research to exploit advanced techniques of computational fluid dynamics and capabilities of supercomputers to gain understanding of complicated internal flows of viscous, essentially incompressible fluids like blood. Another to use understanding to design better artificial hearts and valves.

  6. Formation of tough composite joints

    International Nuclear Information System (INIS)

    Brun, M.K.

    1997-05-01

    Joints which exhibit tough fracture behavior were formed in a composite with a Si/SiC matrix reinforced with Textron SCS-6 fibers with either boron nitride or silicon nitride fiber coatings. In composites with BN coatings fibers were aligned uniaxially, while composites with Si 3 N 4 -coated fibers had a 0/90 degree architecture. Lapped joints (joints with overlapping fingers) were necessary to obtain tough behavior. Geometrical requirements necessary to avoid brittle joint failure have been proposed. Joints with a simple overlap geometry (only a few fingers) would have to be very long in order to prevent brittle failure. Typical failure in these joints is caused by a crack propagating along the interfaces between the joint fingers. Joints of the same overall length, but with geometry changed to be symmetric about the joint centerline and with an extra shear surface exhibited tough fractures accompanied with extensive fiber pullout. The initial matrix cracking of these joints was relatively low because cracks propagated easily through the ends of the fingers. Joints with an optimized stepped sawtooth geometry produced composite-like failures with the stress/strain curves containing an elastic region followed by a region of rising stress with an increase of strain. Increasing the fiber/matrix interfacial strength from 9 to 25 MPa, by changing the fiber coating, increased matrix cracking and ultimate strength of the composite significantly. The best joints had matrix cracking stress and ultimate strength of 138 and 240 MPa, respectively. Joint failure was preceded by multiple matrix cracking in the entire composite. The high strength of the joints will permit building of structures containing joints with only a minor reduction of design stresses

  7. Artificial sensory organs: latest progress.

    Science.gov (United States)

    Nakamura, Tatsuo; Inada, Yuji; Shigeno, Keiji

    2018-03-01

    This study introduces the latest progress on the study of artificial sensory organs, with a special emphasis on the clinical results of artificial nerves and the concept of in situ tissue engineering. Peripheral nerves have a strong potential for regeneration. An artificial nerve uses this potential to recover a damaged peripheral nerve. The polyglycolic acid collagen tube (PGA-C tube) is a bio-absorbable tube stuffed with collagen of multi-chamber structure that consists of thin collagen films. The clinical application of the PGA-C tube began in 2002 in Japan. The number of PGA-C tubes used is now beyond 300, and satisfactory results have been reported on peripheral nerve repairs. This PGA-C tube is also effective for patients suffering from neuropathic pain.

  8. Multicentric reticulohistiocytosis (lipoid dermatoarthritis)

    International Nuclear Information System (INIS)

    Fiumicelli, A.; Bruni, L.

    1990-01-01

    The authors report their experience with 3 cases of multicentric reticulohistiocytosis observed over 6 years of outpatient radiological practice. The condition presents with the following radiological patterns: 1) clear-cut erosions of the articular surfaces, especially in the distal interphalangeal joints of the hand and in the metatarso-phalangeal joints of the feet, with symmetrical distributions (not necessarily); 2) osteolytic punched-out areas in the epiphyseal spongiosa, ranging in size from 1 mm to over 1 cm; 3) no osteoporosis, no osteoproliferative or periosteal reactions, not even in the presence of large osteoarticular destructions; 4) frequent atlanto-epistropheal subluxation; 5) articular ankylosis at the sacroiliac joints only. The association of the above patterns and the relativity benign clinical course distinguish multicentric reticulohistiocytosis from rheumatoid arthritis, psoriasic arthritis, erosive osteoarthritis, and gout. Reliable diagnosis can be suggested on the basis of radiological findings alone, even before cutaneous or mucosal lesions appear -which are, at any rate, not sure to appear and typical of nails only. An unquestionable diagnosis can be made at histology of synovial and/or cutaneous nodules. Multicentric reticulohistiocytosis is considered an uncommon condition (nearly 100 cases in international literature to 1989); the authors believe it to be commoner though often misdiagnosed as a 'variant of rehumatoid arthritis'

  9. The application and development of artificial intelligence in smart clothing

    Science.gov (United States)

    Wei, Xiong

    2018-03-01

    This paper mainly introduces the application of artificial intelligence in intelligent clothing. Starting from the development trend of artificial intelligence, analysis the prospects for development in smart clothing with artificial intelligence. Summarize the design key of artificial intelligence in smart clothing. Analysis the feasibility of artificial intelligence in smart clothing.

  10. Advanced Applications of Neural Networks and Artificial Intelligence: A Review

    OpenAIRE

    Koushal Kumar; Gour Sundar Mitra Thakur

    2012-01-01

    Artificial Neural Network is a branch of Artificial intelligence and has been accepted as a new computing technology in computer science fields. This paper reviews the field of Artificial intelligence and focusing on recent applications which uses Artificial Neural Networks (ANN’s) and Artificial Intelligence (AI). It also considers the integration of neural networks with other computing methods Such as fuzzy logic to enhance the interpretation ability of data. Artificial Neural Networks is c...

  11. Artificial intelligence executive summary

    International Nuclear Information System (INIS)

    Wamsley, S.J.; Purvis, E.E. III

    1984-01-01

    Artificial intelligence (AI) is a high technology field that can be used to provide problem solving diagnosis, guidance and for support resolution of problems. It is not a stand alone discipline, but can also be applied to develop data bases for retention of the expertise that is required for its own knowledge base. This provides a way to retain knowledge that otherwise may be lost. Artificial Intelligence Methodology can provide an automated construction management decision support system, thereby restoring the manager's emphasis to project management

  12. Securing Communication via Transmission of Artificial Noise by Both Sides: Bipolar-Beamforming Optimization

    Directory of Open Access Journals (Sweden)

    Yongkai Zhou

    2013-01-01

    Full Text Available The paper considers the secure transmission in a wireless environment in which both the transmitter (Alice and the legitimate receiver (Bob send artificial noise (AN to interfere with the eavesdropper (Eve. Optimal design is analyzed in detail for this AN-by-both-side model to deal with Eve’s stochastic channel condition and random spatial distribution. Bipolar-beamforming is first proposed to jointly design Alice and Bob’s transmitting signals. By optimally assigning the transmitting antenna for Bob and allocating the power ratio between Alice’s information and the AN signal, maximum secrecy capacity can be achieved. Simulation is done to illustrate the process of bipolar-beamforming optimization. Results show that the AN-by-both-side model has good secrecy performance on both average and extreme conditions as Eve approaches Alice or Bob.

  13. Performance of artificial neural networks and genetical evolved artificial neural networks unfolding techniques

    International Nuclear Information System (INIS)

    Ortiz R, J. M.; Martinez B, M. R.; Vega C, H. R.; Gallego D, E.; Lorente F, A.; Mendez V, R.; Los Arcos M, J. M.; Guerrero A, J. E.

    2011-01-01

    With the Bonner spheres spectrometer neutron spectrum is obtained through an unfolding procedure. Monte Carlo methods, Regularization, Parametrization, Least-squares, and Maximum Entropy are some of the techniques utilized for unfolding. In the last decade methods based on Artificial Intelligence Technology have been used. Approaches based on Genetic Algorithms and Artificial Neural Networks (Ann) have been developed in order to overcome the drawbacks of previous techniques. Nevertheless the advantages of Ann still it has some drawbacks mainly in the design process of the network, vg the optimum selection of the architectural and learning Ann parameters. In recent years the use of hybrid technologies, combining Ann and genetic algorithms, has been utilized to. In this work, several Ann topologies were trained and tested using Ann and Genetically Evolved Artificial Neural Networks in the aim to unfold neutron spectra using the count rates of a Bonner sphere spectrometer. Here, a comparative study of both procedures has been carried out. (Author)

  14. Prediction Analysis of Weld-Bead and Heat Affected Zone in TIG welding using Artificial Neural Networks

    Science.gov (United States)

    Saldanha, Shamith L.; Kalaichelvi, V.; Karthikeyan, R.

    2018-04-01

    TIG Welding is a high quality form of welding which is very popular in industries. It is one of the few types of welding that can be used to join dissimilar metals. Here a weld joint is formed between stainless steel and monel alloy. It is desired to have control over the weld geometry of such a joint through the adjustment of experimental parameters which are welding current, wire feed speed, arc length and the shielding gas flow rate. To facilitate the automation of the same, a model of the welding system is needed. However the underlying welding process is complex and non-linear, and analytical methods are impractical for industrial use. Therefore artificial neural networks (ANN) are explored for developing the model, as they are well-suited for modelling non-linear multi-variate data. Feed-forward neural networks with backpropagation training algorithm are used, and the data for training the ANN taken from experimental work. There are four outputs corresponding to the weld geometry. Different training and testing phases were carried out using MATLAB software and ANN approximates the given data with minimum amount of error.

  15. Artificial intelligence in astronomy - a forecast.

    Science.gov (United States)

    Adorf, H. M.

    Since several years artificial intelligence techniques are being actively used in astronomy, particularly within the Hubble Space Telescope project. This contribution reviews achievements, analyses some problems of using artificial intelligence in an astronomical environment, and projects current AI programming trends into the future.

  16. Artificial Lipid Membranes: Past, Present, and Future.

    Science.gov (United States)

    Siontorou, Christina G; Nikoleli, Georgia-Paraskevi; Nikolelis, Dimitrios P; Karapetis, Stefanos K

    2017-07-26

    The multifaceted role of biological membranes prompted early the development of artificial lipid-based models with a primary view of reconstituting the natural functions in vitro so as to study and exploit chemoreception for sensor engineering. Over the years, a fair amount of knowledge on the artificial lipid membranes, as both, suspended or supported lipid films and liposomes, has been disseminated and has helped to diversify and expand initial scopes. Artificial lipid membranes can be constructed by several methods, stabilized by various means, functionalized in a variety of ways, experimented upon intensively, and broadly utilized in sensor development, drug testing, drug discovery or as molecular tools and research probes for elucidating the mechanics and the mechanisms of biological membranes. This paper reviews the state-of-the-art, discusses the diversity of applications, and presents future perspectives. The newly-introduced field of artificial cells further broadens the applicability of artificial membranes in studying the evolution of life.

  17. Implanted artificial heart with radioisotope power source

    Energy Technology Data Exchange (ETDEWEB)

    Shumakov, V I; Griaznov, G M; Zhemchuzhnikov, G N; Kiselev, I M; Osipov, A P

    1983-02-01

    An atomic artificial heart for orthotopic implantation was developed with the following characteristics: volume, 1.2 L; weight, 1.5 kg; radioisotope power, 45 W; operating life, up to 5 years; hemodynamics, similar to natural hemodynamics. The artificial heart includes a thermal drive with systems for regulating power, feeding steam into the cylinders, return of the condensate to the steam generator, and delivery of power to the ventricles and heat container. The artificial heart is placed in an artificial pericardium partially filled with physiologic solution. It uses a steam engine with two operating cylinders that separately drive the left and right ventricles. There is no electronic control system in the proposed design. The operation of the heat engine is controlled, with preservation of autoregulation by the vascular system of the body. The separate drives for the ventricles is of primary importance as it provides for operation of the artificial heart through control of cardiac activity by venous return. Experimental testing on a hydromechanical bench demonstrated effective autoregulation.

  18. Antithrombotic artificial organs

    Energy Technology Data Exchange (ETDEWEB)

    Takamatsu, T; Fukada, E; Saegusa, M; Hasegawa, T

    1971-07-12

    A new antithrombotic material useful for making artificial organs (artificial blood vessel, artificial heart, etc.) can be prepared by graft-polymerizing an acrylic ester (methyl methacrylate, methyl acrylate, ethyl acrylate, etc.) with a synthetic fiber (teflon, etc.). The graft-polymerization can be carried out by means of gamma radiation with cobalt 60 (dose rate 2.6x10/sup 3/ r/min., total dose 8x10/sup 4/ to 3.5x10/sup 5/ r). A graft ratio of 5 to 80% is attainable. In one example, a tubular sample made of teflon fiber having an inner diameter of 5 to 10 mm was immersed into methyl methacrylate in an ampoule in the absence of air and exposed to cobalt 60 gamma ray at the dose rate of 3.18x10/sup 3/ rad/min. After extraction with acetone, the sample was dried. The total dose was 3.5x10/sup 5/ rad and the graft ratio was ca. 25%. The sample was transplanted to vena cava of dog. No formation of thrombus was observed by autopsy (4 months after the transplantation). In control (teflon tube not graft-polymerized) thrombus was observed by autopsy 7 days after the transplantation.

  19. Artificial Intelligence (AI) Studies in Water Resources

    OpenAIRE

    Ay, Murat; Özyıldırım, Serhat

    2018-01-01

    Artificial intelligence has been extensively used in many areas such as computer science,robotics, engineering, medicine, translation, economics, business, and psychology. Variousstudies in the literature show that the artificial intelligence in modeling approaches give closeresults to the real data for solution of linear, non-linear, and other systems. In this study, wereviewed the current state-of-the-art and progress on the modelling of artificial intelligence forwater variables: rainfall-...

  20. Artificial Organs 2017: A Year in Review.

    Science.gov (United States)

    Malchesky, Paul S

    2018-03-01

    In this Editor's Review, articles published in 2017 are organized by category and summarized. We provide a brief reflection of the research and progress in artificial organs intended to advance and better human life while providing insight for continued application of these technologies and methods. Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. Peer-reviewed Special Issues this year included contributions from the 12th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion edited by Dr. Akif Undar, Artificial Oxygen Carriers edited by Drs. Akira Kawaguchi and Jan Simoni, the 24th Congress of the International Society for Mechanical Circulatory Support edited by Dr. Toru Masuzawa, Challenges in the Field of Biomedical Devices: A Multidisciplinary Perspective edited by Dr. Vincenzo Piemonte and colleagues and Functional Electrical Stimulation edited by Dr. Winfried Mayr and colleagues. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years. © 2018 International Center for

  1. Artificial Intelligence and Artificial Life%人工智能与人工生命

    Institute of Scientific and Technical Information of China (English)

    班晓娟; 王昭顺; 刘宏伟; 涂序彦

    2002-01-01

    人工生命(Artificial Life)是一门正在迅速发展的新兴学科.将人工智能(Artificial Intelligence)方法与人工生命方法相结合,是目前人工智能研究的新方向.该文介绍了人工生命的概念和研究方法,分析了人工智能目前的困难以及人工生命与人工智能的区别与联系,并介绍了几种二者结合的实例.

  2. A fully rotational joint underactuated finger mechanism and its kinematics analysis

    Directory of Open Access Journals (Sweden)

    Wu Licheng

    2016-09-01

    Full Text Available The characteristic features of underactuated finger are compact structure, large grasping force, and simple operation. It has a wide application prospect in the fields of industrial robot, humanoid robot, human artificial limb, and space robot. A new type of fully rotating joint linkage-based underactuated mechanism is proposed, and a new method based on the law of minimum resistance is presented to realize the equivalent mechanism at different contact conditions of the finger and the kinematical analysis based on the equivalent mechanism. The kinematic equations and the limit moving position of the mechanism are derived using the proposed method. Finally, the numerical simulation is carried out by MATLAB program. The correctness and effectiveness of the proposed method are verified. The simulation results show that the proposed mechanism has a large grasp space and can achieve good grasp trajectory.

  3. Artificial Intelligence in Civil Engineering

    OpenAIRE

    Lu, Pengzhen; Chen, Shengyong; Zheng, Yujun

    2012-01-01

    Artificial intelligence is a branch of computer science, involved in the research, design, and application of intelligent computer. Traditional methods for modeling and optimizing complex structure systems require huge amounts of computing resources, and artificial-intelligence-based solutions can often provide valuable alternatives for efficiently solving problems in the civil engineering. This paper summarizes recently developed methods and theories in the developing direction for applicati...

  4. Experimental joint immobilization in guinea pigs. Effects on the knee joint

    Science.gov (United States)

    Marcondesdesouza, J. P.; Machado, F. F.; Sesso, A.; Valeri, V.

    1980-01-01

    In young and adult guinea pigs, the aftermath experimentally induced by the immobilization of the knee joint in hyperextended forced position was studied. Joint immobilization which varied from one to nine weeks was attained by plaster. Eighty knee joints were examined macro and microscopically. Findings included: (1) muscular hypotrophy and joint stiffness in all animals, directly proportional to the length of immobilization; (2) haemoarthrosis in the first week; (3) intra-articular fibrous tissue proliferation ending up with fibrous ankylosis; (4) hyaline articular cartilage erosions; (5) various degrees of destructive menisci changes. A tentative explanation of the fibrous tissue proliferation and of the cartilage changes is offered.

  5. Prosthesis of the wrist-joint

    Energy Technology Data Exchange (ETDEWEB)

    Feldmeier, C.

    1983-02-25

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated.

  6. Artificial intelligence in cardiology.

    Science.gov (United States)

    Bonderman, Diana

    2017-12-01

    Decision-making is complex in modern medicine and should ideally be based on available data, structured knowledge and proper interpretation in the context of an individual patient. Automated algorithms, also termed artificial intelligence that are able to extract meaningful patterns from data collections and build decisions upon identified patterns may be useful assistants in clinical decision-making processes. In this article, artificial intelligence-based studies in clinical cardiology are reviewed. The text also touches on the ethical issues and speculates on the future roles of automated algorithms versus clinicians in cardiology and medicine in general.

  7. Spatially Resolved Artificial Chemistry

    DEFF Research Database (Denmark)

    Fellermann, Harold

    2009-01-01

    Although spatial structures can play a crucial role in chemical systems and can drastically alter the outcome of reactions, the traditional framework of artificial chemistry is a well-stirred tank reactor with no spatial representation in mind. Advanced method development in physical chemistry has...... made a class of models accessible to the realms of artificial chemistry that represent reacting molecules in a coarse-grained fashion in continuous space. This chapter introduces the mathematical models of Brownian dynamics (BD) and dissipative particle dynamics (DPD) for molecular motion and reaction...

  8. Spatially Resolved Artificial Chemistry

    DEFF Research Database (Denmark)

    Fellermann, Harold

    2009-01-01

    made a class of models accessible to the realms of artificial chemistry that represent reacting molecules in a coarse-grained fashion in continuous space. This chapter introduces the mathematical models of Brownian dynamics (BD) and dissipative particle dynamics (DPD) for molecular motion and reaction......Although spatial structures can play a crucial role in chemical systems and can drastically alter the outcome of reactions, the traditional framework of artificial chemistry is a well-stirred tank reactor with no spatial representation in mind. Advanced method development in physical chemistry has...

  9. 21 CFR 145.181 - Artificially sweetened canned pineapple.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Artificially sweetened canned pineapple. 145.181... § 145.181 Artificially sweetened canned pineapple. (a) Artificially sweetened canned pineapple is the food that conforms to the definition and standard of identity prescribed for canned pineapple by § 145...

  10. A Characterization of the Utility of Using Artificial Intelligence to Test Two Artificial Intelligence Systems

    Directory of Open Access Journals (Sweden)

    Jeremy Straub

    2013-05-01

    Full Text Available An artificial intelligence system, designed for operations in a real-world environment faces a nearly infinite set of possible performance scenarios. Designers and developers, thus, face the challenge of validating proper performance across both foreseen and unforeseen conditions, particularly when the artificial intelligence is controlling a robot that will be operating in close proximity, or may represent a danger, to humans. While the manual creation of test cases allows limited testing (perhaps ensuring that a set of foreseeable conditions trigger an appropriate response, this may be insufficient to fully characterize and validate safe system performance. An approach to validating the performance of an artificial intelligence system using a simple artificial intelligence test case producer (AITCP is presented. The AITCP allows the creation and simulation of prospective operating scenarios at a rate far exceeding that possible by human testers. Four scenarios for testing an autonomous navigation control system are presented: single actor in two-dimensional space, multiple actors in two-dimensional space, single actor in three-dimensional space, and multiple actors in three-dimensional space. The utility of using the AITCP is compared to that of human testers in each of these scenarios.

  11. Synthetic biology and the moral significance of artificial life

    DEFF Research Database (Denmark)

    Christiansen, Andreas

    2016-01-01

    , Powell and Savulescu's definition of artificial life does not capture all core projects of synthetic biology or the ethical concerns that have been voiced, and their definition of moral significance fails to take into account the possibility that creating artificial life is conditionally acceptable......I discuss the moral significance of artificial life within synthetic biology via a discussion of Douglas, Powell and Savulescu's paper 'Is the creation of artificial life morally significant’. I argue that the definitions of 'artificial life’ and of 'moral significance’ are too narrow. Douglas...

  12. Artificial Intelligence.

    Science.gov (United States)

    Lawrence, David R; Palacios-González, César; Harris, John

    2016-04-01

    It seems natural to think that the same prudential and ethical reasons for mutual respect and tolerance that one has vis-à-vis other human persons would hold toward newly encountered paradigmatic but nonhuman biological persons. One also tends to think that they would have similar reasons for treating we humans as creatures that count morally in our own right. This line of thought transcends biological boundaries-namely, with regard to artificially (super)intelligent persons-but is this a safe assumption? The issue concerns ultimate moral significance: the significance possessed by human persons, persons from other planets, and hypothetical nonorganic persons in the form of artificial intelligence (AI). This article investigates why our possible relations to AI persons could be more complicated than they first might appear, given that they might possess a radically different nature to us, to the point that civilized or peaceful coexistence in a determinate geographical space could be impossible to achieve.

  13. Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

    Science.gov (United States)

    Hanazaki, Kazuhiro; Munekage, Masaya; Kitagawa, Hiroyuki; Yatabe, Tomoaki; Munekage, Eri; Shiga, Mai; Maeda, Hiromichi; Namikawa, Tsutomu

    2016-09-01

    The incidence of diabetes is increasing at an unprecedented pace and has become a serious health concern worldwide during the last two decades. Despite this, adequate glycemic control using an artificial pancreas has not been established, although the 21st century has seen rapid developments in this area. Herein, we review current topics in glycemic control for both the wearable artificial pancreas for type 1 and type 2 diabetic patients and the bedside artificial pancreas for surgical diabetic patients. In type 1 diabetic patients, nocturnal hypoglycemia associated with insulin therapy remains a serious problem that could be addressed by the recent development of a wearable artificial pancreas. This smart phone-like device, comprising a real-time, continuous glucose monitoring system and insulin pump system, could potentially significantly reduce nocturnal hypoglycemia compared with conventional glycemic control. Of particular interest in this space are the recent inventions of a low-glucose suspend feature in the portable systems that automatically stops insulin delivery 2 h following a glucose sensor value <70 mg/dL and a bio-hormonal pump system consisting of insulin and glucagon pumps. Perioperative tight glycemic control using a bedside artificial pancreas with the closed-loop system has also proved safe and effective for not only avoiding hypoglycemia, but also for reducing blood glucose level variability resulting in good surgical outcomes. We hope that a more sophisticated artificial pancreas with closed-loop system will now be taken up for routine use worldwide, providing enormous relief for patients suffering from uncontrolled hyperglycemia, hypoglycemia, and/or variability in blood glucose concentrations.

  14. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    Directory of Open Access Journals (Sweden)

    Evangelos I. Avgoulas

    2016-07-01

    Full Text Available There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  15. Artificial humidification for the mechanically ventilated patient

    OpenAIRE

    Selvaraj, Nelson

    2010-01-01

    Caring for patients who are mechanically ventilated poses many\\ud challenges for critical care nurses. It is important to humidify the\\ud patient’s airways artificially to prevent complications such as\\ud ventilator-associated pneumonia. There is no gold standard to\\ud determine which type of humidification is best for patients who\\ud are artificially ventilated. This article provides an overview of\\ud commonly used artificial humidification for mechanically ventilated\\ud patients and discuss...

  16. Prosthesis of the wrist-joint

    International Nuclear Information System (INIS)

    Feldmeier, C.

    1983-01-01

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated. (orig.) [de

  17. Design of mechanical joints

    CERN Document Server

    Blake, Alexander

    2018-01-01

    A cornerstone publication that covers the basic principles and practical considerations of design methodology for joints held by rivets, bolts, weld seams, and adhesive materials, Design of Mechanical Joints gives engineers the practical results and formulas they need for the preliminary design of mechanical joints, combining the essential topics of joint mechanics...strength of materials...and fracture control to provide a complete treatment of problems pertinent to the field of mechanical connections.

  18. Part I. Remembering No. 2 (Ladislav Loerinc). EMO joint venture, joint-stock company - really completely useless organ?

    International Nuclear Information System (INIS)

    Blaha, M.

    2008-01-01

    In this chapter author reviewed the story of the EMO joint venture, joint-stock company, between Slovenske elektrarne, a. s. and EdF. EMO joint venture, joint-stock company, was established to complete the Mochovce nuclear power plant. EMO joint venture, joint-stock company was closed after one year of work. History of EMO joint venture, joint-stock company, was described by its former general manager Mr. Ladislav Loerinc.

  19. Effect of Strain Rate on Joint Strength and Failure Mode of Lead-Free Solder Joints

    Science.gov (United States)

    Lin, Jian; Lei, Yongping; Fu, Hanguang; Guo, Fu

    2018-03-01

    In surface mount technology, the Sn-3.0Ag-0.5Cu solder joint has a shorter impact lifetime than a traditional lead-tin solder joint. In order to improve the impact property of SnAgCu lead-free solder joints and identify the effect of silver content on tensile strength and impact property, impact experiments were conducted at various strain rates on three selected SnAgCu based solder joints. It was found that joint failure mainly occurred in the solder material with large plastic deformation under low strain rate, while joint failure occurred at the brittle intermetallic compound layer without any plastic deformation at a high strain rate. Joint strength increased with the silver content in SnAgCu alloys in static tensile tests, while the impact property of the solder joint decreased with increasing silver content. When the strain rate was low, plastic deformation occurred with failure and the tensile strength of the Sn-3.0Ag-0.5Cu solder joint was higher than that of Sn-0.3Ag-0.7Cu; when the strain rate was high, joint failure mainly occurred at the brittle interface layer and the Sn-0.3Ag-0.7Cu solder joint had a better impact resistance with a thinner intermetallic compound layer.

  20. Forming a multinational joint venture

    International Nuclear Information System (INIS)

    Bhatia, N.K.; Garb, R.H.; Statton, T.D.

    1990-01-01

    This paper discusses the basis and mechanics for forming a multinational joint venture. The topics of the paper include the motivations for a joint venture, selection of the appropriate co-venturer, management of the multinational joint venture, and the joint venture agreement. The authors state that a joint venture is not applicable or desirable in all instances and to be successful, must be carefully planned

  1. Identifying artificial selection signals in the chicken genome.

    Directory of Open Access Journals (Sweden)

    Yunlong Ma

    Full Text Available Identifying the signals of artificial selection can contribute to further shaping economically important traits. Here, a chicken 600k SNP-array was employed to detect the signals of artificial selection using 331 individuals from 9 breeds, including Jingfen (JF, Jinghong (JH, Araucanas (AR, White Leghorn (WL, Pekin-Bantam (PB, Shamo (SH, Gallus-Gallus-Spadiceus (GA, Rheinlander (RH and Vorwerkhuhn (VO. Per the population genetic structure, 9 breeds were combined into 5 breed-pools, and a 'two-step' strategy was used to reveal the signals of artificial selection. GA, which has little artificial selection, was defined as the reference population, and a total of 204, 155, 305 and 323 potential artificial selection signals were identified in AR_VO, PB, RH_WL and JH_JF, respectively. We also found signals derived from standing and de-novo genetic variations have contributed to adaptive evolution during artificial selection. Further enrichment analysis suggests that the genomic regions of artificial selection signals harbour genes, including THSR, PTHLH and PMCH, responsible for economic traits, such as fertility, growth and immunization. Overall, this study found a series of genes that contribute to the improvement of chicken breeds and revealed the genetic mechanisms of adaptive evolution, which can be used as fundamental information in future chicken functional genomics study.

  2. Artificial Intelligence Techniques and Methodology

    OpenAIRE

    Carbonell, Jaime G.; Sleeman, Derek

    1982-01-01

    Two closely related aspects of artificial intelligence that have received comparatively little attention in the recent literature are research methodology, and the analysis of computational techniques that span multiple application areas. We believe both issues to be increasingly significant as Artificial Intelligence matures into a science and spins off major application efforts. It is imperative to analyze the repertoire of AI methods with respect to past experience, utility in new domains,...

  3. Artificial Intelligence.

    Science.gov (United States)

    Wash, Darrel Patrick

    1989-01-01

    Making a machine seem intelligent is not easy. As a consequence, demand has been rising for computer professionals skilled in artificial intelligence and is likely to continue to go up. These workers develop expert systems and solve the mysteries of machine vision, natural language processing, and neural networks. (Editor)

  4. Artificial sweetener; Jinko kanmiryo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    The patents related to the artificial sweetener that it is introduced to the public in 3 years from 1996 until 1998 are 115 cases. The sugar quality which makes an oligosaccharide and sugar alcohol the subject is greatly over 28 cases of the non-sugar quality in the one by the kind as a general tendency of these patents at 73 cases in such cases as the Aspartame. The method of manufacture patent, which included new material around other peptides, the oligosaccharide and sugar alcohol isn`t inferior to 56 cases of the formation thing patent at 43 cases, and pays attention to the thing, which is many by the method of manufacture, formation. There is most improvement of the quality of sweetness with 31 cases in badness of the aftertaste which is characteristic of the artificial sweetener and so on, and much stability including the improvement in the flavor of food by the artificial sweetener, a long time and dissolution, fluid nature and productivity and improvement of the economy such as a cost are seen with effect on a purpose. (NEDO)

  5. Artificial Neural Networks and Instructional Technology.

    Science.gov (United States)

    Carlson, Patricia A.

    1991-01-01

    Artificial neural networks (ANN), part of artificial intelligence, are discussed. Such networks are fed sample cases (training sets), learn how to recognize patterns in the sample data, and use this experience in handling new cases. Two cognitive roles for ANNs (intelligent filters and spreading, associative memories) are examined. Prototypes…

  6. Joint imaging

    International Nuclear Information System (INIS)

    Hengst, W.

    1984-01-01

    Joint imaging is a proven diagnostic procedure which has become indispensable to the detection and treatment of different joint diseases in almost all disciplines. The method is suited for early diagnosis of joint affections both in soft tissue and bone which cannot be detected by X-ray or other procedures. The local activity accumulation depends on the rate of metabolism and is visualized in the scan, which in turn enables the extension and floridity of focal lesions to be evaluated and followed-up. Although joint scans may often give hints to probabilities relevant to differential diagnosis, the method is non-specific and only useful if based on the underlying clinical picture and X-ray finding, if possible. The radiation exposure is very low and does not represent a hazard in cases of adequate assessment of indication. In pregnant women and children the assessment of indication has to be based on very strict principles. The method is suited for out-patient diagnosis and can be applied in all installations equipped with a gamma camera and a technetium generator. (orig.) [de

  7. Managing Joint Production Motivation

    DEFF Research Database (Denmark)

    Lindenberg, Siegwart; Foss, Nicolai Juul

    2011-01-01

    We contribute to the microfoundations of organizational performance by proffering the construct of joint production motivation. Under such motivational conditions individuals see themselves as part of a joint endeavor, each with his or her own roles and responsibilities; generate shared...... representations of actions and tasks; cognitively coordinate cooperation; and choose their own behaviors in terms of joint goals. Using goal-framing theory, we explain how motivation for joint production can be managed by cognitive/symbolic management and organizational design....

  8. Mechanics of Suture Joints

    Science.gov (United States)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  9. Digital Genesis: Computers, Evolution and Artificial Life

    OpenAIRE

    Taylor, Tim; Dorin, Alan; Korb, Kevin

    2015-01-01

    The application of evolution in the digital realm, with the goal of creating artificial intelligence and artificial life, has a history as long as that of the digital computer itself. We illustrate the intertwined history of these ideas, starting with the early theoretical work of John von Neumann and the pioneering experimental work of Nils Aall Barricelli. We argue that evolutionary thinking and artificial life will continue to play an integral role in the future development of the digital ...

  10. Generalised joint hypermobility and knee joint hypermobility: prevalence, knee joint symptoms and health-related quality of life in a Danish adult population.

    Science.gov (United States)

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina; Østengaard, Lasse; Golightly, Yvonne M; Juul-Kristensen, Birgit

    2017-10-27

    Several biomechanical factors, such as knee joint hypermobility (KJH), are suggested to play a role in the etiology of knee joint symptoms and knee osteoarthritis. Nevertheless, the prevalence or consequences of KJH solely or included in the classification of generalized joint hypermobility (GJHk) is unknown for a general population. Therefore, the objectives were to report the prevalence of self-reported GJHk and KJH, as well as the association of these conditions to knee joint symptoms, severity and duration of symptoms, and health-related quality of life (HRQoL) in a Danish adult population. This study is a cross-sectional population-based survey of 2056 Danish adults. Respondents received online questionnaires of GJHk and KJH, knee joint symptoms, the severity and duration of these, as well as HRQoL. Total response rate was 49% (n = 1006). The prevalence of self-reported GJHk and KJH was 13% and 23%, mostly representing women. More than half of the respondents with GJHk and KJH had knee joint symptoms. The odds for reporting knee joint symptoms, severity of knee joint symptoms and duration of knee joint symptoms were twice as high for respondents with GJHk and KJH. Respondents with GJHk and KJH reported lower HRQoL. GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower HRQoL. The impact of these conditions on HRQoL is comparable with knee osteoarthritis. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  11. Joint Intentionality

    Directory of Open Access Journals (Sweden)

    Koreň Ladislav

    2016-03-01

    Full Text Available According to the shared intentionality hypothesis proposed by Michael Tomasello, two cognitive upgrades – joint and collective intentionality, respectively – make human thinking unique. Joint intentionality, in particular, is a mindset supposed to account for our early, species-specific capacity to participate in collaborative activities involving two (or a few agents. In order to elucidate such activities and their proximate cognitive-motivational mechanism, Tomasello draws on philosophical accounts of shared intentionality. I argue that his deference to such cognitively demanding accounts of shared intentional activities is problematic if his theoretical ambition is in part to show that and how early (prelinguistic and precultural capacities for joint action contribute to the development of higher cognitive capacities.

  12. [Experimental study on novel hybrid artificial trachea transplantation].

    Science.gov (United States)

    Liu, Wenliang; Xiao, Peng; Liang, Hengxing; An, Ran; Cheng, Gang; Yu, Fenglei

    2014-04-01

    We developed and designed a new type of artificial trachea. The basic structure of the artificial trachea was polytetrafluoroethylene vascular prosthesis linked with titanium rings on both sides. Dualmesh was sutured on titanium rings. This experimentation follows the replacement of trachea in dogs with a combined artificial trachea to investigate the feasibility of this type of prosthesis. Sixteen dogs were implanted with the combined artificial trachea after resection of 5 cm of cervical trachea. The 5 cm-long trachea of dogs on the necks were resected and the reconstruction of the defect of the trachea was performed with trachea prosthesis. According to the method of trachea reconstruction, the models were divided into 2 groups, artificial trachea implantation group (the control group, n = 8) and group of artificial trachea implantation with growth factor (the experimental group, n = 8). Then computer tomography scan (CT), bronchoscope and pathologic examination were conducted periodically to observe the healing state of the hybrid artificial trachea. None of the dogs died during operation of cervical segmental trachea construction. But four dogs in the control group died of apnea in succession because artificial trachea was displaced and the lumen was obstructed, while 2 dogs died in the experimental group. In the first month there was granulation around anastomosis with slight stenosis. The rest of dogs were well alive until they were sacrificed 14 months later. The mean survival time of the experimental group was longer than that of the control group. The rate of infection, anastomotic dehiscence, severe stenosis and accidental death in the experimental group were lower than the control group (P anastomosis effectively but infections and split or displacement of the artificial trachea are still major problems affecting long-term survival of the animals. Application of growth factors to a certain extent promotes tissue healing by changing the local environment.

  13. Bringing Artificial Gravity into the Classroom

    Science.gov (United States)

    Thompson, Grant; Aning, Isaac

    2018-01-01

    We recently conducted an experimental test of artificial gravity by placing various species of plants in centrifuges and analyzed the plants’ germination and growth. This research project incorporated several topics covered in undergraduate astronomy, biology, and physics courses. Given the interest of introductory astronomy students in artificial gravity and their pre-existing images of applications such as rotating spacecraft from pop culture, the results of the experiment may provide a gateway to discuss artificial gravity beyond teaching the traditional examples of Newton’s laws. We will discuss the experiment in detail and provide suggestions for how the experiment could be incorporated into your classroom.

  14. Artificial heart for humanoid robot

    Science.gov (United States)

    Potnuru, Akshay; Wu, Lianjun; Tadesse, Yonas

    2014-03-01

    A soft robotic device inspired by the pumping action of a biological heart is presented in this study. Developing artificial heart to a humanoid robot enables us to make a better biomedical device for ultimate use in humans. As technology continues to become more advanced, the methods in which we implement high performance and biomimetic artificial organs is getting nearer each day. In this paper, we present the design and development of a soft artificial heart that can be used in a humanoid robot and simulate the functions of a human heart using shape memory alloy technology. The robotic heart is designed to pump a blood-like fluid to parts of the robot such as the face to simulate someone blushing or when someone is angry by the use of elastomeric substrates and certain features for the transport of fluids.

  15. The temporomandibular joint

    International Nuclear Information System (INIS)

    Campbell, W.

    1984-01-01

    Whilst the temporomandibular joint is in many ways unique, it is subject to all the diseases and disorders found in joints in other parts of the human skeleton. By far the most common disorder is injury, followed by arthropathy, acute and chronic dislocations, ankylosis, and in rare instances, neoplasms. The diagnosis and management of the temporomandibular joint are the primary responsibility of the oral surgeon. Nevertheless, this anatomical region is an area in which the cooperation of medical and dental disciplines may be required for the satisfactory conclusion of treatment. The more so when the disease process involves either associated psychosomatic illness or malignancy. The mainstay of the diagnosis is a careful radiological examination of the joint. There exists a delicate relationship between the dentition, the muscles of mastication, and the temporomandibular articulation, which is controlled by arthrokinetic reflex activity of the branches of the 5th cranial nerve. Imbalance between one or more of the components of this integrated system frequently leads to disturbances in function. Pain-dysfunction disorders constitute the larger part of temporomandibular joint disturbances generally encountered

  16. Modeling the benefits of an artificial gravity countermeasure coupled with exercise and vibration

    Science.gov (United States)

    Goel, Rahul; Kaderka, Justin; Newman, Dava

    2012-01-01

    The current, system-specific countermeasures to space deconditioning have limited success with the musculoskeletal system in long duration missions. Artificial gravity (AG) that is produced by short radius centrifugation has been hypothesized as an effective countermeasure because it reintroduces an acceleration field in space; however, AG alone might not be enough stimuli to preserve the musculoskeletal system. A novel combination of AG coupled with one-legged squats on a vibrating platform may preserve muscle and bone in the lower limbs to a greater extent than the current exercise paradigm. The benefits of the proposed countermeasure have been analyzed through the development of a simulation platform. Ground reaction force data and motion data were collected using a motion capture system while performing one-legged and two-legged squats in 1-G. The motion was modeled in OpenSim, an open-source software, and inverse dynamics were applied in order to determine the muscle and reaction forces of lower limb joints. Vibration stimulus was modeled by adding a 20 Hz sinusoidal force of 0.5 body weight to the force plate data. From the numerical model in a 1-G acceleration field, muscle forces for quadriceps femoris, plantar flexors and glutei increased substantially for one-legged squats with vibration compared to one- or two-legged squats without vibration. Additionally, joint reaction forces for one-legged squats with vibration also increased significantly compared to two-legged squats with or without vibration. Higher muscle forces and joint reaction forces might help to stimulate muscle activation and bone modeling and thus might reduce musculoskeletal deconditioning. These results indicate that the proposed countermeasure might surpass the performance of the current space countermeasures and should be further studied as a method of mitigating musculoskeletal deconditioning.

  17. Biologically inspired technologies using artificial muscles

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2005-01-01

    After billions of years of evolution, nature developed inventions that work, which are appropriate for the intended tasks and that last. The evolution of nature led to the introduction of highly effective and power efficient biological mechanisms that are scalable from micron to many meters in size. Imitating these mechanisms offers enormous potentials for the improvement of our life and the tools we use. Humans have always made efforts to imitate nature and we are increasingly reaching levels of advancement where it becomes significantly easier to imitate, copy, and adapt biological methods, processes and systems. Some of the biomimetic technologies that have emerged include artificial muscles, artificial intelligence, and artificial vision to which significant advances in materials science, mechanics, electronics, and computer science have contributed greatly. One of the newest fields of biomimetics is the electroactive polymers (EAP) that are also known as artificial muscles. To take advantage of these materials, efforts are made worldwide to establish a strong infrastructure addressing the need for comprehensive analytical modeling of their operation mechanism and develop effective processing and characterization techniques. The field is still in its emerging state and robust materials are not readily available however in recent years significant progress has been made and commercial products have already started to appear. This paper covers the state-of-the-art and challenges to making artificial muscles and their potential biomimetic applications.

  18. INFLUENCE OF ELECTROACUPUNCTURE ON ARTIFICIAL ABORTION-INDUCED SIDE EFFECTS

    Institute of Scientific and Technical Information of China (English)

    田丽颖

    2001-01-01

    In the present study, the effect of electroecupuncture (EA) of acupoints of Ren, Spleen and Stomach Meridians on artificial abortion-induced side effects was observed in 100 artificial abortion women. In comparison with 45 artificial abortion women in the control group (who had not accepted EA treatment), EA possessed significant effects in relieving abdominal pain, reducing vaginal bleeding duration, lowering infection rate and infertility rate after artificial abortion operation.

  19. USE OF ARTIFICIAL INTELLIGENCE TECHNIQUES IN QUALITY IMPROVING PROCESS

    OpenAIRE

    KALİTE İYİLEŞTİRME SÜRECİNDE YAPAY ZEKÃ KAYA; Orhan ENGİN

    2005-01-01

    Today, changing of competition conditions and customer preferences caused to happen many differences in the viewpoint of firms' quality studies. At the same time, improvements in computer technologies accelerated use of artificial intelligence. Artificial intelligence technologies are being used to solve many industry problems. In this paper, we investigated the use of artificial intelligence techniques to solve quality problems. The artificial intelligence techniques, which are used in quali...

  20. Vibroacoustic Modeling of Mechanically Coupled Structures: Artificial Spring Technique Applied to Light and Heavy Mediums

    Directory of Open Access Journals (Sweden)

    L. Cheng

    1996-01-01

    Full Text Available This article deals with the modeling of vibrating structures immersed in both light and heavy fluids, and possible applications to noise control problems and industrial vessels containing fluids. A theoretical approach, using artificial spring systems to characterize the mechanical coupling between substructures, is extended to include fluid loading. A structure consisting of a plate-ended cylindrical shell and its enclosed acoustic cavity is analyzed. After a brief description of the proposed technique, a number of numerical results are presented. The analysis addresses the following specific issues: the coupling between the plate and the shell; the coupling between the structure and the enclosure; the possibilities and difficulties regarding internal soundproofing through modifications of the joint connections; and the effects of fluid loading on the vibration of the structure.

  1. Benign joint hypermobility syndrome

    Directory of Open Access Journals (Sweden)

    Iwona Słowińska

    2014-11-01

    Full Text Available Benign joint hypermobility syndrome (BJHS, commonly known as loose ligament syndrome, is a non-inflammatory rheumatic condition. It is characterised by a greater than normal range of motion of the joints of the limbs and spine. The prevalence of the syndrome in preschool-age children is estimated to be between 2% and 30%, depending on ethnic background (with higher prevalence in Asian and African populations, occurring most often in families with a history of the condition and more frequently in girls. This paper presents a case report of a 12-year-old girl. A broad differential diagnostic approach to recurrent joint inflammation with joint effusion and pain made it possible to establish a diagnosis of benign joint hypermobility syndrome. The child met the Brighton criteria; her Beighton score was 7 out of 9. Patient education aimed at eliminating abnormal joint movement and an appropriate rehabilitation programme play key roles in the treatment of BJHS.

  2. Abstraction in artificial intelligence and complex systems

    CERN Document Server

    Saitta, Lorenza

    2013-01-01

    Abstraction is a fundamental mechanism underlying both human and artificial perception, representation of knowledge, reasoning and learning. This mechanism plays a crucial role in many disciplines, notably Computer Programming, Natural and Artificial Vision, Complex Systems, Artificial Intelligence and Machine Learning, Art, and Cognitive Sciences. This book first provides the reader with an overview of the notions of abstraction proposed in various disciplines by comparing both commonalities and differences.  After discussing the characterizing properties of abstraction, a formal model, the K

  3. Readings in artificial intelligence and software engineering

    CERN Document Server

    Rich, Charles

    1986-01-01

    Readings in Artificial Intelligence and Software Engineering covers the main techniques and application of artificial intelligence and software engineering. The ultimate goal of artificial intelligence applied to software engineering is automatic programming. Automatic programming would allow a user to simply say what is wanted and have a program produced completely automatically. This book is organized into 11 parts encompassing 34 chapters that specifically tackle the topics of deductive synthesis, program transformations, program verification, and programming tutors. The opening parts p

  4. Artificial limb representation in amputees

    OpenAIRE

    van den Heiligenberg, FMZ; Orlov, T; Macdonald, SN; Duff, EP; Henderson Slater, JDE; Beckmann, CF; Johansen-Berg, H; Culham, JC; Makin, TR

    2018-01-01

    The human brain contains multiple hand-selective areas, in both the sensorimotor and visual systems. Could our brain repurpose neural resources, originally developed for supporting hand function, to represent and control artificial limbs? We studied individuals with congenital or acquired hand-loss (hereafter one-handers) using functional MRI. We show that the more one-handers use an artificial limb (prosthesis) in their everyday life, the stronger visual hand-selective areas in the lateral o...

  5. Vehicle Routing with Three-dimensional Container Loading Constraints—Comparison of Nested and Joint Algorithms

    Science.gov (United States)

    Koloch, Grzegorz; Kaminski, Bogumil

    2010-10-01

    In the paper we examine a modification of the classical Vehicle Routing Problem (VRP) in which shapes of transported cargo are accounted for. This problem, known as a three-dimensional VRP with loading constraints (3D-VRP), is appropriate when transported commodities are not perfectly divisible, but they have fixed and heterogeneous dimensions. In the paper restrictions on allowable cargo positionings are also considered. These restrictions are derived from business practice and they extended the baseline 3D-VRP formulation as considered by Koloch and Kaminski (2010). In particular, we investigate how additional restrictions influence relative performance of two proposed optimization algorithms: the nested and the joint one. Performance of both methods is compared on artificial problems and on a big-scale real life case study.

  6. Natural and artificial atoms for quantum computation

    Energy Technology Data Exchange (ETDEWEB)

    Buluta, Iulia; Ashhab, Sahel; Nori, Franco, E-mail: fnori@riken.jp [Advanced Science Institute, RIKEN, Wako-shi, Saitama, 351-0198 (Japan)

    2011-10-15

    Remarkable progress towards realizing quantum computation has been achieved using natural and artificial atoms as qubits. This paper presents a brief overview of the current status of different types of qubits. On the one hand, natural atoms (such as neutral atoms and ions) have long coherence times, and could be stored in large arrays, providing ideal 'quantum memories'. On the other hand, artificial atoms (such as superconducting circuits or semiconductor quantum dots) have the advantage of custom-designed features and could be used as 'quantum processing units'. Natural and artificial atoms can be coupled with each other and can also be interfaced with photons for long-distance communications. Hybrid devices made of natural/artificial atoms and photons may provide the next-generation design for quantum computers.

  7. Artificial neural networks application for modeling of friction stir welding effects on mechanical properties of 7075-T6 aluminum alloy

    Science.gov (United States)

    Maleki, E.

    2015-12-01

    Friction stir welding (FSW) is a relatively new solid-state joining technique that is widely adopted in manufacturing and industry fields to join different metallic alloys that are hard to weld by conventional fusion welding. Friction stir welding is a very complex process comprising several highly coupled physical phenomena. The complex geometry of some kinds of joints makes it difficult to develop an overall governing equations system for theoretical behavior analyse of the friction stir welded joints. Weld quality is predominantly affected by welding effective parameters, and the experiments are often time consuming and costly. On the other hand, employing artificial intelligence (AI) systems such as artificial neural networks (ANNs) as an efficient approach to solve the science and engineering problems is considerable. In present study modeling of FSW effective parameters by ANNs is investigated. To train the networks, experimental test results on thirty AA-7075-T6 specimens are considered, and the networks are developed based on back propagation (BP) algorithm. ANNs testing are carried out using different experimental data that they are not used during networks training. In this paper, rotational speed of tool, welding speed, axial force, shoulder diameter, pin diameter and tool hardness are regarded as inputs of the ANNs. Yield strength, tensile strength, notch-tensile strength and hardness of welding zone are gathered as outputs of neural networks. According to the obtained results, predicted values for the hardness of welding zone, yield strength, tensile strength and notch-tensile strength have the least mean relative error (MRE), respectively. Comparison of the predicted and the experimental results confirms that the networks are adjusted carefully, and the ANN can be used for modeling of FSW effective parameters.

  8. Sacroiliac joint dysfunction.

    Science.gov (United States)

    Ilaslan, Hakan; Arslan, Ahmet; Koç, Omer Nadir; Dalkiliç, Turker; Naderi, Sait

    2010-07-01

    Sacroiliac joint dysfunction is a disorder presenting with low back and groin pain. It should be taken into consideration during the preoperative differential diagnosis of lumbar disc herniation, lumbar spinal stenosis and facet syndrome. Four cases with sacroiliac dysfunction are presented. The clinical and radiological signs supported the evidence of sacroiliac dysfunction, and exact diagnosis was made after positive response to sacroiliac joint block. A percutaneous sacroiliac fixation provided pain relief in all cases. The mean VAS scores reduced from 8.2 to 2.2. It is concluded that sacroiliac joint dysfunction diagnosis requires a careful physical examination of the sacroiliac joints in all cases with low back and groin pain. The diagnosis is made based on positive response to the sacroiliac block. Sacroiliac fixation was found to be effective in carefully selected cases.

  9. Metallic joints for very high vacuum; Joints metalliques pour ultra-vide

    Energy Technology Data Exchange (ETDEWEB)

    Paigne, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    After defining three main types of joint; three types of distribution of the tightening force in the clamps are demonstrated; the distribution of stresses, distortion and displacements in these clamps is then calculated by means of the theory of elasticity. This is followed by experimental results on a particular means of tightening (i.e. screw-clamps). From a brief discussion on the behaviour of the clamps it is possible finally to define other types of joint deriving from the main types originally foreseen. (author) [French] Apres avoir defini trois principaux types de joints, on met en evidence trois types de distribution des forces de serrage des brides; puis on calcule a l'aide de la theorie de l'elasticite la distribution des contraintes, deformations et deplacements dans ces brides. On donne ensuite des resultats experimentaux sur un mode de serrage particulier (cas des serres-joints). Une discussion sommaire sur le comportement des brides permet de definir finalement d'autres types de joints derivant des types principaux envisages initialement. (auteur)

  10. Artificial intelligent decision support for low-cost launch vehicle integrated mission operations

    Science.gov (United States)

    Szatkowski, Gerard P.; Schultz, Roger

    1988-01-01

    The feasibility, benefits, and risks associated with Artificial Intelligence (AI) Expert Systems applied to low cost space expendable launch vehicle systems are reviewed. This study is in support of the joint USAF/NASA effort to define the next generation of a heavy-lift Advanced Launch System (ALS) which will provide economical and routine access to space. The significant technical goals of the ALS program include: a 10 fold reduction in cost per pound to orbit, launch processing in under 3 weeks, and higher reliability and safety standards than current expendables. Knowledge-based system techniques are being explored for the purpose of automating decision support processes in onboard and ground systems for pre-launch checkout and in-flight operations. Issues such as: satisfying real-time requirements, providing safety validation, hardware and Data Base Management System (DBMS) interfacing, system synergistic effects, human interfaces, and ease of maintainability, have an effect on the viability of expert systems as a useful tool.

  11. Acromioclavicular joint separation

    Directory of Open Access Journals (Sweden)

    Devan Pandya, BS

    2018-04-01

    Full Text Available History of present illness: A 30-year-old male was brought in by ambulance to the emergency department as a trauma activation after a motorcycle accident. The patient was the helmeted rider of a motorcycle traveling at an unknown speed when he lost control and was thrown off his vehicle. He denied loss of consciousness, nausea, or vomiting. The patient’s vital signs were stable and his only complaint was pain around his left shoulder. On exam, the patient had a prominent left clavicle without skin compromise. He had adequate range of motion in the left shoulder with moderate pain, and his left upper extremity was neurovascularly intact. Significant findings: Plain films of the left shoulder showed elevation of the left clavicle above the acromion. There was an increase in the acromioclavicular (AC and coracoclavicular (CC distances (increased joint distances marked with red and blue arrows, respectively. A normal AC joint measures 1-3 mm whereas a normal CC distance measures 11-13 mm.1 The injury was classified as a Rockwood type III AC joint separation. Discussion: The AC joint is a synovial joint between an oval facet on the acromion and a similar facet on the distal end of the clavicle. Horizontal stability is provided by the AC joint while axial stability is provided by the CC joint.2,3 AC joint injuries account for about 9%-12% of shoulder girdle injuries, and the most common mechanism is direct trauma.4,5 Initial evaluation with imaging includes plain films with three views: the anterior-posterior (AP view with the shoulder in internal and external rotation as well as an axillary, or scapula-Y view (sensitivity 40%, specificity 90% for all films.6,7 AC joint injuries are classified by the Rockwood system.8 Type I involves a sprain or incomplete tear of the AC ligaments with an intact CC ligament. The AC joint appears normal on X-ray, but can become widened with stress, achieved by having the patient hold a 10-15 pound weight from each

  12. Hip joint injection

    Science.gov (United States)

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  13. Artificial tears potpourri: a literature review

    Directory of Open Access Journals (Sweden)

    Moshirfar M

    2014-07-01

    Full Text Available Majid Moshirfar,1 Kasey Pierson,2,* Kamalani Hanamaikai,3,* Luis Santiago-Caban,1 Valliammai Muthappan,1 Samuel F Passi11Department of Ophthalmology, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 2University of Arizona College of Medicine, Phoenix, Phoenix, AZ, USA; 3A T Still University, School of Osteopathic Medicine in Arizona, Mesa, AZ, USA *These authors contributed equally to this work Abstract: Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. Keywords: dry eye, tear film, dysfunctional tear syndrome, ophthalmic lubricant, artificial tears, lipid layer, tear osmolarity, TBUT, Systane®, Refresh®, Blink®, GenTeal®, Soothe®, Lacrisert®, ocular surface inflammatory disease, Sjogren

  14. Development of Ankle Foot Orthosis (AFO Using Pneumatic Artificial Muscle for Disabled Children

    Directory of Open Access Journals (Sweden)

    Ishak N.Z.

    2017-01-01

    Full Text Available Ankle foot orthosis (AFO are commonly used to correct the instabilities and joint weakness of lower limb. In this research, AFO was developed by using pneumatic artificial muscle (PAM to prevent plantarflexion to occur and also to correct the foot from the inversion syndrome. The research started with designing the AFO by using SolidWorks software based on anthropometry measurement data (n=5, age=12 years old. The mechanical simulation was conducted by using Autodesk Inventor software to obtain a safety factor before the fabrication process was conducted. The AFO was fabricated using 3D printer and the thermoplastic elastomer (TPE rubber was selected as the material. PAM was tested by using test bed machine to generate the force and contraction by muscle. The result shows that the PAM was suitable for low speed as the displacement was greater. The AFO could be valuable for the gait rehabilitation.

  15. Airway Complications of Total Artificial Heart.

    Science.gov (United States)

    Pathak, Vikas; Donovan, Colin; Malhotra, Rajiv

    2017-02-01

    The total artificial heart is the mechanical device which is used as a bridge to the heart transplant in patients with biventricular failure. Due to the mechanical nature of the device, patients receiving total artificial heart (TAH) require to be on anticoagulation therapy. Hemorrhage and coagulopathy are few of the known complications of TAH.

  16. Contribution of artificial intelligence to operation

    International Nuclear Information System (INIS)

    Malvache, P.; Mourlevat, J.L.

    1993-01-01

    Artificial Intelligence techniques are already used in nuclear plants for assistance to operation: synthesis from numerous information sources may be then derived, based on expert knowledge. Artificial intelligence may be used also for quality and reliability assessment of software-based control-command systems. Various expert systems developed by CEA, EDF and Framatome are presented

  17. A Characterization of the Utility of Using Artificial Intelligence to Test Two Artificial Intelligence Systems

    OpenAIRE

    Straub, Jeremy; Huber, Justin

    2013-01-01

    An artificial intelligence system, designed for operations in a real-world environment faces a nearly infinite set of possible performance scenarios. Designers and developers, thus, face the challenge of validating proper performance across both foreseen and unforeseen conditions, particularly when the artificial intelligence is controlling a robot that will be operating in close proximity, or may represent a danger, to humans. While the manual creation of test cases allows limited testing (p...

  18. Algorithms and architectures of artificial intelligence

    CERN Document Server

    Tyugu, E

    2007-01-01

    This book gives an overview of methods developed in artificial intelligence for search, learning, problem solving and decision-making. It gives an overview of algorithms and architectures of artificial intelligence that have reached the degree of maturity when a method can be presented as an algorithm, or when a well-defined architecture is known, e.g. in neural nets and intelligent agents. It can be used as a handbook for a wide audience of application developers who are interested in using artificial intelligence methods in their software products. Parts of the text are rather independent, so that one can look into the index and go directly to a description of a method presented in the form of an abstract algorithm or an architectural solution. The book can be used also as a textbook for a course in applied artificial intelligence. Exercises on the subject are added at the end of each chapter. Neither programming skills nor specific knowledge in computer science are expected from the reader. However, some p...

  19. Carbon dioxide fixation by artificial photosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Ibusuki, Takashi; Koike, Kazuhide; Ishitani, Osamu [National Inst. for Resources and Environment, AIST, MITI, Tsukuba, Ibaraki (Japan)

    1993-12-31

    Green plants can absorb atmospheric CO{sub 2} and transform it to sugars, carbohydrates through their photosynthetic systems, but they become the source of CO{sub 2} when they are dead. This is the reason why artificial leaves which can be alive forever should be developed to meet with global warming due to the increase of CO{sub 2} concentration. The goal of artificial photosynthesis is not to construct the same system as the photosynthetic one, but to mimic the ability of green plants to utilize solar energy to make high energy chemicals. Needless to say, the artificial photosynthetic system is desired to be as simple as possible and to be as efficient as possible. From the knowledge on photosynthesis and the results of previous investigations, the critical components of artificial photosynthetic system are understood as follows: (1) light harvesting chromophore, (2) a center for electron transfer and charge separation, (3) catalytic sites for converting small molecules like water and CO{sub 2} (mutilelectron reactions) which are schematically described.

  20. Reproducibility of pop-ins in laboratory testing of welded joints

    Directory of Open Access Journals (Sweden)

    Berejnoi C.

    2000-01-01

    Full Text Available The pop-in phenomenon, quite common in fracture mechanics tests of welded joints, corresponds to a brittle crack initiation grown from a local brittle zone (LBZ that is arrested in reaching the higher toughness material that surrounds this LBZ. A methodology to obtain a high percentage of pop-in occurrence in laboratory testing is necessary to study the pop-in significance. Such a method is introduced in this work and includes the consumable combination and welding procedures for the SMAW welding process to generate artificial LBZ. In order to find out the influence of the loading state upon the pop-in phenomenon, laboratory CTOD tests were performed using two specimen configurations: some single edge-notched specimens were loaded on a three-point bending (SE(B fixture while others were tested in tensile load (SE(T. A higher frequency of pop-in occurrence was observed in the SE(B geometry.

  1. Status and headway of the clinical application of artificial ligaments

    Directory of Open Access Journals (Sweden)

    Tianwu Chen

    2015-01-01

    Full Text Available The authors first reviewed the history of clinical application of artificial ligaments. Then, the status of clinical application of artificial ligaments was detailed. Some artificial ligaments possessed comparable efficacy to, and fewer postoperative complications than, allografts and autografts in ligament reconstruction, especially for the anterior cruciate ligament. At the end, the authors focused on the development of two types of artificial ligaments: polyethylene glycol terephthalate artificial ligaments and tissue-engineered ligaments. In conclusion, owing to the advancements in surgical techniques, materials processing, and weaving methods, clinical application of some artificial ligaments so far has demonstrated good outcomes and will become a trend in the future.

  2. The handbook of artificial intelligence

    CERN Document Server

    Barr, Avron

    1982-01-01

    The Handbook of Artificial Intelligence, Volume II focuses on the improvements in artificial intelligence (AI) and its increasing applications, including programming languages, intelligent CAI systems, and the employment of AI in medicine, science, and education. The book first elaborates on programming languages for AI research and applications-oriented AI research. Discussions cover scientific applications, teiresias, applications in chemistry, dependencies and assumptions, AI programming-language features, and LISP. The manuscript then examines applications-oriented AI research in medicine

  3. What are artificial neural networks?

    DEFF Research Database (Denmark)

    Krogh, Anders

    2008-01-01

    Artificial neural networks have been applied to problems ranging from speech recognition to prediction of protein secondary structure, classification of cancers and gene prediction. How do they work and what might they be good for? Udgivelsesdato: 2008-Feb......Artificial neural networks have been applied to problems ranging from speech recognition to prediction of protein secondary structure, classification of cancers and gene prediction. How do they work and what might they be good for? Udgivelsesdato: 2008-Feb...

  4. STANFORD ARTIFICIAL INTELLIGENCE PROJECT.

    Science.gov (United States)

    ARTIFICIAL INTELLIGENCE , GAME THEORY, DECISION MAKING, BIONICS, AUTOMATA, SPEECH RECOGNITION, GEOMETRIC FORMS, LEARNING MACHINES, MATHEMATICAL MODELS, PATTERN RECOGNITION, SERVOMECHANISMS, SIMULATION, BIBLIOGRAPHIES.

  5. Variable camber wing based on pneumatic artificial muscles

    Science.gov (United States)

    Yin, Weilong; Liu, Libo; Chen, Yijin; Leng, Jinsong

    2009-07-01

    As a novel bionic actuator, pneumatic artificial muscle has high power to weight ratio. In this paper, a variable camber wing with the pneumatic artificial muscle is developed. Firstly, the experimental setup to measure the static output force of pneumatic artificial muscle is designed. The relationship between the static output force and the air pressure is investigated. Experimental result shows the static output force of pneumatic artificial muscle decreases nonlinearly with increasing contraction ratio. Secondly, the finite element model of the variable camber wing is developed. Numerical results show that the tip displacement of the trailing-edge increases linearly with increasing external load and limited with the maximum static output force of pneumatic artificial muscles. Finally, the variable camber wing model is manufactured to validate the variable camber concept. Experimental result shows that the wing camber increases with increasing air pressure and that it compare very well with the FEM result.

  6. Parameter identification for joint elements in a revolute-joint detector manipulator

    International Nuclear Information System (INIS)

    Preissner, C.; Shu, D.; Royston, T.

    2005-01-01

    A revolute-joint robot is being developed for the spatial positioning of an x-ray detector at the Advanced Photon Source. Commercially available revolute-joint manipulators do not meet our size, positioning, or payload specifications. One idea being considered is the modification of a commercially available robot, with the goal of improving the repeatability and trajectory accuracy. Theoretical, computational, and experimental procedures are being used to (1) identify, (2) simulate the dynamics of an existing robot system using a multibody approach, and eventually (3) design an improved version, with low dynamic positioning uncertainty. A key aspect of the modeling and performance prediction is accurate stiffness and damping values for the robot joints. This paper discusses the experimental identification of the stiffness and damping parameters for one robot harmonic drive joint

  7. Artificial reefs and reef restoration in the Laurentian Great Lakes

    Science.gov (United States)

    McLean, Matthew W.; Roseman, Edward; Pritt, Jeremy J.; Kennedy, Gregory W.; Manny, Bruce A.

    2015-01-01

    We reviewed the published literature to provide an inventory of Laurentian Great Lakes artificial reef projects and their purposes. We also sought to characterize physical and biological monitoring for artificial reef projects in the Great Lakes and determine the success of artificial reefs in meeting project objectives. We found records of 6 artificial reefs in Lake Erie, 8 in Lake Michigan, 3 in Lakes Huron and Ontario, and 2 in Lake Superior. We found 9 reefs in Great Lakes connecting channels and 6 reefs in Great Lakes tributaries. Objectives of artificial reef creation have included reducing impacts of currents and waves, providing safe harbors, improving sport-fishing opportunities, and enhancing/restoring fish spawning habitats. Most reefs in the lakes themselves were incidental (not created purposely for fish habitat) or built to improve local sport fishing, whereas reefs in tributaries and connecting channels were more frequently built to benefit fish spawning. Levels of assessment of reef performance varied; but long-term monitoring was uncommon as was assessment of physical attributes. Artificial reefs were often successful at attracting recreational species and spawning fish; however, population-level benefits of artificial reefs are unclear. Stressors such as sedimentation and bio-fouling can limit the effectiveness of artificial reefs as spawning enhancement tools. Our investigation underscores the need to develop standard protocols for monitoring the biological and physical attributes of artificial structures. Further, long-term monitoring is needed to assess the benefits of artificial reefs to fish populations and inform future artificial reef projects.

  8. Computed Flow Through An Artificial Heart Valve

    Science.gov (United States)

    Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

  9. ARTIFICIAL INTELLIGENCE APPLICATIONS IN THE FINANCIAL SECTOR

    OpenAIRE

    Adrian Cozgarea; Gabriel Cozgarea; Andrei Stanciu

    2008-01-01

    The present paper exposes some of artificial intelligence specific technologies regarding financial sector. Through non-deterministic solutions and simple algorithms, artificial intelligence could become a base alternative for solving financial problems which require complex mathematic calculations or complex optimization.

  10. Dynamic modeling method of the bolted joint with uneven distribution of joint surface pressure

    Science.gov (United States)

    Li, Shichao; Gao, Hongli; Liu, Qi; Liu, Bokai

    2018-03-01

    The dynamic characteristics of the bolted joints have a significant influence on the dynamic characteristics of the machine tool. Therefore, establishing a reasonable bolted joint dynamics model is helpful to improve the accuracy of machine tool dynamics model. Because the pressure distribution on the joint surface is uneven under the concentrated force of bolts, a dynamic modeling method based on the uneven pressure distribution of the joint surface is presented in this paper to improve the dynamic modeling accuracy of the machine tool. The analytic formulas between the normal, tangential stiffness per unit area and the surface pressure on the joint surface can be deduced based on the Hertz contact theory, and the pressure distribution on the joint surface can be obtained by the finite element software. Futhermore, the normal and tangential stiffness distribution on the joint surface can be obtained by the analytic formula and the pressure distribution on the joint surface, and assigning it into the finite element model of the joint. Qualitatively compared the theoretical mode shapes and the experimental mode shapes, as well as quantitatively compared the theoretical modal frequencies and the experimental modal frequencies. The comparison results show that the relative error between the first four-order theoretical modal frequencies and the first four-order experimental modal frequencies is 0.2% to 4.2%. Besides, the first four-order theoretical mode shapes and the first four-order experimental mode shapes are similar and one-to-one correspondence. Therefore, the validity of the theoretical model is verified. The dynamic modeling method proposed in this paper can provide a theoretical basis for the accurate dynamic modeling of the bolted joint in machine tools.

  11. Hairy polyelectrolyte brushes-grafted thermosensitive microgels as artificial synovial fluid for simultaneous biomimetic lubrication and arthritis treatment.

    Science.gov (United States)

    Liu, Guoqiang; Liu, Zhilu; Li, Na; Wang, Xiaolong; Zhou, Feng; Liu, Weimin

    2014-11-26

    We report the fabrication of poly(3-sulfopropyl methacrylate potassium salt) (PSPMK) brushes grafted poly(N-isopropylacrylamide) (PNIPAAm) microgels and their potential as artificial synovial fluid for biomimetic aqueous lubrication and arthritis treatment. The negatively charged PSPMK brushes and thermosensitive PNIPAAm microgels play water-based hydration lubrication and temperature-triggered drug release, respectively. Under soft friction pairs, an ultralow coefficient of friction was achieved, while the hairy thermosensitive microgels showed a desirable temperature-triggered drugs release performance. Such a soft charged hairy microgel offers great possibility for designing intelligent synovial fluid. What is more, the combination of lubrication and drug loading capabilities enables the large clinical potential of novel soft hairy nanoparticles as synthetic joint lubricant fluid in arthritis treatment.

  12. Recalculation of an artificially released avalanche with SAMOS and validation with measurements from a pulsed Doppler radar

    Directory of Open Access Journals (Sweden)

    R. Sailer

    2002-01-01

    Full Text Available A joint experiment was carried out on 10 February 1999 by the Swiss Federal Institute for Snow and Avalanche Research (SFISAR and the Austrian Institute for Avalanche and Torrent Research (AIATR, of the Federal Office and Re-search Centre for Forests, BFW to measure forces and velocities at the full scale experimental site CRÊTA BESSE in VALLÉE DE LA SIONNE, Canton du Valais, Switzerland. A huge avalanche could be released artificially, which permitted extensive investigations (dynamic measurements, im-provement of measurement systems, simulation model verification, design of protective measures, etc.. The results of the velocity measurements from the dual frequency pulsed Doppler avalanche radar of the AIATR and the recalculation with the numerical simulation model SAMOS are explained in this paper.

  13. Artificial lateral line with biomimetic neuromasts to emulate fish sensing

    International Nuclear Information System (INIS)

    Yang Yingchen; Chen Nannan; Tucker, Craig; Hu Huan; Liu Chang; Nguyen, Nam; Lockwood, Michael; Jones, Douglas L; Bleckmann, Horst

    2010-01-01

    Hydrodynamic imaging using the lateral line plays a critical role in fish behavior. To engineer such a biologically inspired sensing system, we developed an artificial lateral line using MEMS (microelectromechanical system) technology and explored its localization capability. Arrays of biomimetic neuromasts constituted an artificial lateral line wrapped around a cylinder. A beamforming algorithm further enabled the artificial lateral line to image real-world hydrodynamic events in a 3D domain. We demonstrate that the artificial lateral line system can accurately localize an artificial dipole source and a natural tail-flicking crayfish under various conditions. The artificial lateral line provides a new sense to man-made underwater vehicles and marine robots so that they can sense like fish.

  14. Magnetically-actuated artificial cilia for microfluidic propulsion

    NARCIS (Netherlands)

    Khaderi, S.N.; Craus, C.B.; Hussong, J.; Schorr, N.; Belardi, J.; Westerweel, J.; Prucker, O.; Ruehe, J.; Toonder, den J.M.J.; Onck, P.R.

    2011-01-01

    In this paper we quantitatively analyse the performance of magnetically-driven artificial cilia for labon-a-chip applications. The artificial cilia are fabricated using thin polymer films with embeddedmagnetic nano-particles and their deformation is studied under different external magnetic fields

  15. Neutron detection at jet using artificial diamond detectors

    International Nuclear Information System (INIS)

    Pillon, M.; Angelone, M.; Lattanzi, D.; Marinelli, M.; Milani, E.; Tucciarone, A.; Verona-Rinati, G.; Popovichev, S.; Montereali, R.M.; Vincenti, M.A.; Murari, A.

    2007-01-01

    Artificial diamond neutron detectors recently proved to be promising devices to measure the neutron production on large experimental fusion machines. Diamond detectors are very promising detectors to be used in fusion environment due to their radiation hardness, low sensitivity to gamma rays, fast response and high energy resolution. High quality 'electronic grade' diamond films are produced through microwave chemical vapour deposition (CVD) technique. Two CVD diamond detectors have been installed and operated at joint European torus (JET), Culham Science Centre, UK. One of these detectors was a polycrystalline CVD diamond film; about 12 mm 2 area and 30 μm thickness while the second was a monocrystalline film of about 5 mm 2 area and 20 μm thick. Both diamonds were covered with 2 μm of lithium fluoride (LiF) 95% enriched in 6 Li. The LiF layer works as a neutron-to-charged particle converter so these detectors can measure thermalized neutrons. Their output signals were compared to JET total neutron yield monitors (KN1 diagnostic) realized with a set of uranium fission chambers. Despite their small active volumes the diamond detectors were able to measure total neutron yields with good reliability and stability during the recent JET experimental campaign of 2006

  16. Quantifying the impact of transient joint symptoms, chronic joint symptoms, and arthritis: a population-based approach.

    Science.gov (United States)

    Busija, Lucy; Buchbinder, Rachelle; Osborne, Richard H

    2009-10-15

    To estimate the prevalence and co-occurrence of self-reported doctor-diagnosed arthritis, chronic joint symptoms (pain, aching, stiffness, or swelling on most days for a month), and transient joint symptoms (pain, aching, stiffness, or swelling but not on most days for a month), and to compare the sociodemographic characteristics, activity limitations, and health-related quality of life (HRQOL) of people with joint conditions with those who have no self-reported doctor-diagnosed arthritis and no joint symptoms. Data from the 2004 population-based South Australian Health Omnibus Survey (n = 2,840, ages 18-96 years) were used in the study. Activity limitations were assessed using 10 activity limitations questions from the Short Form 36 health survey. HRQOL was assessed using the Assessment of Quality of Life scale. Half of all respondents reported having joint problems, with 26%, 11%, and 13% reporting self-reported doctor-diagnosed arthritis, chronic joint symptoms, and transient joint symptoms, respectively. Chronic joint conditions (self-reported doctor-diagnosed arthritis and chronic joint symptoms) accounted for 74% of all joint problems and were associated with higher odds of activity limitations and poorer HRQOL. The frequency of transient and chronic joint symptoms was highest among middle-aged participants (ages 45-54 years for transient and 45-64 years for chronic joint symptoms) and those who had a body mass index in the obese range. Prevalence of self-reported doctor-diagnosed arthritis increased with age and was higher among women and those who were overweight or obese. This study documented the high prevalence and impact of joint conditions in the community. Chronic joint conditions affect daily life and are substantial barriers for effective public health interventions aimed at reducing obesity and inactivity.

  17. Medical applications of artificial intelligence

    CERN Document Server

    Agah, Arvin

    2013-01-01

    Enhanced, more reliable, and better understood than in the past, artificial intelligence (AI) systems can make providing healthcare more accurate, affordable, accessible, consistent, and efficient. However, AI technologies have not been as well integrated into medicine as predicted. In order to succeed, medical and computational scientists must develop hybrid systems that can effectively and efficiently integrate the experience of medical care professionals with capabilities of AI systems. After providing a general overview of artificial intelligence concepts, tools, and techniques, Medical Ap

  18. Bibliography: Artificial Intelligence.

    Science.gov (United States)

    Smith, Richard L.

    1986-01-01

    Annotates reference material on artificial intelligence, mostly at an introductory level, with applications to education and learning. Topics include: (1) programing languages; (2) expert systems; (3) language instruction; (4) tutoring systems; and (5) problem solving and reasoning. (JM)

  19. Application of artificial intelligence to the management of urological cancer.

    Science.gov (United States)

    Abbod, Maysam F; Catto, James W F; Linkens, Derek A; Hamdy, Freddie C

    2007-10-01

    Artificial intelligence techniques, such as artificial neural networks, Bayesian belief networks and neuro-fuzzy modeling systems, are complex mathematical models based on the human neuronal structure and thinking. Such tools are capable of generating data driven models of biological systems without making assumptions based on statistical distributions. A large amount of study has been reported of the use of artificial intelligence in urology. We reviewed the basic concepts behind artificial intelligence techniques and explored the applications of this new dynamic technology in various aspects of urological cancer management. A detailed and systematic review of the literature was performed using the MEDLINE and Inspec databases to discover reports using artificial intelligence in urological cancer. The characteristics of machine learning and their implementation were described and reports of artificial intelligence use in urological cancer were reviewed. While most researchers in this field were found to focus on artificial neural networks to improve the diagnosis, staging and prognostic prediction of urological cancers, some groups are exploring other techniques, such as expert systems and neuro-fuzzy modeling systems. Compared to traditional regression statistics artificial intelligence methods appear to be accurate and more explorative for analyzing large data cohorts. Furthermore, they allow individualized prediction of disease behavior. Each artificial intelligence method has characteristics that make it suitable for different tasks. The lack of transparency of artificial neural networks hinders global scientific community acceptance of this method but this can be overcome by neuro-fuzzy modeling systems.

  20. Artificial light pollution increases nocturnal vigilance in peahens.

    Science.gov (United States)

    Yorzinski, Jessica L; Chisholm, Sarah; Byerley, Sydney D; Coy, Jeanee R; Aziz, Aisyah; Wolf, Jamie A; Gnerlich, Amanda C

    2015-01-01

    Artificial light pollution is drastically changing the sensory environments of animals. Even though many animals are now living in these changed environments, the effect light pollution has on animal behavior is poorly understood. We investigated the effect of light pollution on nocturnal vigilance in peahens (Pavo cristatus). Captive peahens were exposed to either artificial lighting or natural lighting at night. We employed a novel method to record their vigilance behavior by attaching accelerometers to their heads and continuously monitoring their large head movements. We found that light pollution significantly increases nocturnal vigilance in peahens. Furthermore, the birds faced a trade-off between vigilance and sleep at night: peahens that were more vigilant spent less time sleeping. Given the choice, peahens preferred to roost away from high levels of artificial lighting but showed no preference for roosting without artificial lighting or with low levels of artificial lighting. Our study demonstrates that light pollution can have a substantial impact on animal behavior that can potentially result in fitness consequences.