WorldWideScience

Sample records for artery in-stent restenosis

  1. Causes and prevention of in-stent restenosis of vertebral artery origin after stenting

    International Nuclear Information System (INIS)

    Zhao Huipin; Li Shenmao; Zhang Guangping

    2010-01-01

    Vertebral artery stenosis is an important cause of posterior circulation stroke. Vertebral artery stenosis most commonly occurs at its origin site. In recent years, balloon angioplasty and stent implantation have been widely employed in the treatment of vertebral artery origin stenosis. However, the long term outcome of stent implantation is affected by in-stent restenosis. Multiple contributory factors have been identified, but clear understanding of the overall underlying mechanism remains an enigma. With the development of pathophysiology, prevention and treatment methods of in-stent restenosis have been improved. In recent years, drug-eluting stents, radioactive stents and magnetic stents have been widely applied. To some extent, these stents and drug therapy can solve the problem of restenosis. This article aims to review the clinical application and the up-to-date research progresses in preventing and managing vertebral artery origin restenosis. (authors)

  2. Predictive Factors of In-Stent Restenosis in Renal Artery Stenting: A Retrospective Analysis

    International Nuclear Information System (INIS)

    Vignali, Claudio; Bargellini, Irene; Lazzereschi, Michele; Cioni, Roberto; Petruzzi, Pasquale; Caramella, Davide; Pinto, Stefania; Napoli, Vinicio; Zampa, Virna; Bartolozzi, Carlo

    2005-01-01

    Purpose. To retrospectively evaluate the role of clinical and procedural factors in predicting in-stent restenosis in patients with renovascular disease treated by renal artery stenting. Methods. From 1995 to 2002, 147 patients underwent renal artery stenting for the treatment of significant ostial atherosclerotic stenosis. Patients underwent strict clinical and color-coded duplex ultrasound follow-up. Ninety-nine patients (111 stents), with over 6 months of continuous follow-up (mean 22±12 months, range 6-60 months), were selected and classified according to the presence (group A, 30 patients, 32 lesions) or absence (group B, 69 patients, 79 lesions) of significant in-stent restenosis. A statistical analysis was performed to identify possible preprocedural and procedural predictors of restenosis considering the following data: sex, age, smoking habit, diabetes mellitus, hypertension, serum creatinine, cholesterol and triglyceride levels, renal artery stenosis grade, and stent type, length and diameter. Results. Comparing group A and B patients (χ 2 test), a statistically significant relation was demonstrated between stent diameter and length and restenosis: the risk of in-stent restenosis decreased when the stent was ≥6 mm in diameter and between 15 and 20 mm in length. This finding was confirmed by multiple logistic regression analysis. Stent diameter and length were proved to be significantly related to in-stent restenosis also when evaluating only patients treated by Palmaz stent (71 stents). Conclusion. Although it is based on a retrospective analysis, the present study confirms the importance of correct stent selection in increasing long-term patency, using stents of at least 6 mm in diameter and with a length of approximately 15-20 mm

  3. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  4. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    International Nuclear Information System (INIS)

    Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.

    2012-01-01

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  5. In-stent restenosis of innominate artery with critical stenosis of right internal carotid artery

    International Nuclear Information System (INIS)

    Hussain, S.; Raza, A.; Ahmed, W.

    2011-01-01

    A lady with aortitis syndrome developed in-stent restenosis (ISR) of the innominate artery stent and critical stenosis of right internal carotid artery. The therapeutic challenge was gaining access to the carotid vessel, after treating the innominate artery ISR and all the while using distal protection to circumvent potential cerebral embolism. Percutaneous transluminal angioplasty (PTA) with or without stenting is a safe therapeutic option for re-vascularization of the supra aortic vessels. In the event of re-stenosis, re-treatment with PTA and stenting is safe. Ample evidence-base exists now for carotid artery stenting (CAS) in preference to carotid endarterectomy in patients with stenotic lesions of the carotid vessels. (author)

  6. Experimental study of the preventive effect of 1'03Pd stent on in-stent restenosis in rabbit iliac artery

    International Nuclear Information System (INIS)

    Luo Quanyong; Chen Libo; Yuan Zhibin; Lu Hankui; Zhu Ruisen

    2003-01-01

    Objective: To investigate the ability of γ-emitting 103 Pd radioactive stent implantation for preventing in-stent restenosis in iliac artery of rabbits. Methods: Twenty New Zealand white rabbits were divided into six groups on the basis of radioactivity loading [2.22 (n=3), 5.55 (n=4), 9.25 (n=4), 14.8 (n=3), 22.2 (n=3), 33.3 MBq (n=3)]. 103 Pd stent was implanted in one of the two iliac arteries of each rabbit and nonradioactive stent in the contralateral artery. The rabbits were fed with high fat diet. Treatment efficiency was assessed by angiography and quantitative histomorphometry of the stented iliac segments 28 d after the implantation. Results: Quantitative histomorphometry analysis indicated that 103 Pd stents induced a significant reduction in neointimal area and the percentage of stenosis within radioactive stents was lower compared with that in the control stents. Nevertheless, the suppression of neointima formation by 103 Pd stent implantation was not in a dose-dependent manner. Conclusions: Low-dose intravascular brachytherapy via a γ-particle-emitting 103 Pd radioactive stent potently inhibits neointimal hyperplasia and prevents the in-stent restenosis in rabbit iliac artery. 103 Pd stent implantation probably can be employed as a novel means to prevent in-stent restenosis

  7. Restenosis after stenting in symptomatic vertebral arterial orifice disease and considerations for better outcome

    Science.gov (United States)

    Chang, Jun Young; Park, Hyun; Kwon, Oki

    2017-01-01

    We have performed stenting in 11 patients with symptomatic vertebral arterial orifice stenosis refractory to medical treatment or impairment in anterior circulation. Three of the 11 patients experienced asymptomatic severe in-stent restenosis or occlusion. Bare metal stents were used in those three patients, two of whom received revascularization therapy. Development of sufficient cervical collateral channels reconstituting the distal vertebral artery was the common feature in patients with asymptomatic in-stent restenosis. In selecting appropriate stents, consideration of mechanical strength and drug-eluting properties of a stent according to characteristics of the target vessel is important to reduce the risk of in-stent restenosis. Any decision to perform revascularization should be based on the presence of abundant cervical collaterals as well as clinical symptoms of vertebrobasilar ischemia. PMID:28304206

  8. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  9. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    International Nuclear Information System (INIS)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Wang, Chao-Jan; Liu, Shih-Jung; Hung, Kuo-Chun

    2014-01-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  10. Preliminary application of 320-detector spiral CT with ECG editing for assessing coronary artery in-stent restenosis

    International Nuclear Information System (INIS)

    Li Zhiming; Tan Lilian; Li Shuxin; Fu Xi; He Weihong; Liu Ke; Huang Yong; Yu Lin

    2011-01-01

    Objective: To determine the value of 320-detector spiral CT with retrospective ECG gating and editing software for detecting coronary artery in-stent restenosis. Methods: CT scans of 14 patients with coronary artery stnets were retrospectively analyzed. The examinations were performed using a 320-detector spiral CT scanner and retrospective ECG gating combined with ECG editing software. The image quality of reconstructed coronary artery in-stents was compared before and after the editing of synchronously recorded ECG. The paired-sample t test was used for statistical analysis. Results: Before ECG editing, arrhythmia and in-stent artifact resulted in image blurring, missing arterial segments, significant stepladder artifacts or non-visualization of the interior of stents. Of 14 cases before ECG editing, in-stent restenosis was detected in 10 and patency in 3. The coronary artery stent and distal bifurcation were delineated in one patient. After ECG editing, the image quality of coronary artery stents was improved with detection of in-stent restenosis (4 cases) including the one case that not evaluable before ECG editing. The average image quality score before ECG editing (2.14±0.86) was significantly (P<0.001) lower than that after ECG editing (3.07±0.73). Conclusion: Retrospective ECG gating combined with ECG editing of 320-detector spiral CT can reduce the artifacts produced by arrhythmia or in-stent swings and improve the imaging quality of coronary artery stents. (authors)

  11. Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial.

    Science.gov (United States)

    Lal, Brajesh K; Beach, Kirk W; Roubin, Gary S; Lutsep, Helmi L; Moore, Wesley S; Malas, Mahmoud B; Chiu, David; Gonzales, Nicole R; Burke, J Lee; Rinaldi, Michael; Elmore, James R; Weaver, Fred A; Narins, Craig R; Foster, Malcolm; Hodgson, Kim J; Shepard, Alexander D; Meschia, James F; Bergelin, Robert O; Voeks, Jenifer H; Howard, George; Brott, Thomas G

    2012-09-01

    In the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST), the composite primary endpoint of stroke, myocardial infarction, or death during the periprocedural period or ipsilateral stroke thereafter did not differ between carotid artery stenting and carotid endarterectomy for symptomatic or asymptomatic carotid stenosis. A secondary aim of this randomised trial was to compare the composite endpoint of restenosis or occlusion. Patients with stenosis of the carotid artery who were asymptomatic or had had a transient ischaemic attack, amaurosis fugax, or a minor stroke were eligible for CREST and were enrolled at 117 clinical centres in the USA and Canada between Dec 21, 2000, and July 18, 2008. In this secondary analysis, the main endpoint was a composite of restenosis or occlusion at 2 years. Restenosis and occlusion were assessed by duplex ultrasonography at 1, 6, 12, 24, and 48 months and were defined as a reduction in diameter of the target artery of at least 70%, diagnosed by a peak systolic velocity of at least 3·0 m/s. Studies were done in CREST-certified laboratories and interpreted at the Ultrasound Core Laboratory (University of Washington). The frequency of restenosis was calculated by Kaplan-Meier survival estimates and was compared during a 2-year follow-up period. We used proportional hazards models to assess the association between baseline characteristics and risk of restenosis. Analyses were per protocol. CREST is registered with ClinicalTrials.gov, number NCT00004732. 2191 patients received their assigned treatment within 30 days of randomisation and had eligible ultrasonography (1086 who had carotid artery stenting, 1105 who had carotid endarterectomy). In 2 years, 58 patients who underwent carotid artery stenting (Kaplan-Meier rate 6·0%) and 62 who had carotid endarterectomy (6·3%) had restenosis or occlusion (hazard ratio [HR] 0·90, 95% CI 0·63-1·29; p=0·58). Female sex (1·79, 1·25-2·56), diabetes (2·31, 1·61-3·31

  12. Effects of 32P radioactive stents on in-stent restenosis in a double stent injury model of the porcine coronary arteries

    International Nuclear Information System (INIS)

    Kim, Han-Soo; Chan, Rosanna C.; Kollum, Marc; Au, Arthur; Tio, Fermin O.; Yazdi, Hamid A.; Ajani, Andrew E.; Waksman, Ron

    2001-01-01

    Background: The major limitation of coronary stenting remains in-stent restenosis, due to the development of neointimal proliferation. Radioactive stents have demonstrated the ability to reduce this proliferation in the healthy nonatherosclerotic porcine animal model. However, inhibition of tissue proliferation in the in-stent restenotic lesion in a porcine model is not well characterized. The objective of this study was to examine the efficacy and safety of the 32 P radioactive stent for the treatment of in-stent restenosis in a double stent injury model of the porcine coronaries. Methods and Materials: Eighteen coronary arteries in 9 pigs underwent nonradioactive stent (8 mm in length) implantation. Thirty days after the initial stent implantation, a 32 P radioactive stent (18 mm in length) with an activity of 0 and 18 μCi was implanted to cover the initial stent. The swine were killed 30 days after the second stent implantation. Histomorphometric analysis was performed for vessel area (VA), stent strut area (SSA), intimal area (IA), and lumen area (LA). Results: Injury scores, VA, SSA, and LA were similar among the control and radiated groups. Neointimal formation was significantly reduced after placement of radioactive stents as compared to control in both the overlapped (0.93±0.12 vs. 1.31±0.51 mm 2 , p 2 , p 32 P radioactive stents may be safe and effective in reducing neointimal formation leading to in-stent restenosis. Longer follow-up will be required to examine whether these positive findings can be maintained

  13. Quantification of in-stent restenosis parameters in rabbits by micro-CT

    International Nuclear Information System (INIS)

    Langheinrich, A.C.; Zoerb, C.; Jajima, J.; Lommel, D.; Rau, W.S.; Walker, G.; Mueller, K.M.; Bohle, R.M.

    2005-01-01

    Purpose: The well-defined model of angioplasty and stent implantation in the rabbit aorta is useful in experimental studies of restenosis. This study was performed to evaluate the feasibility of Micro-CT for quantification of in-stent restenosis in a rabbit aortic in-stent restenosis model. Material and Methods: To induce in-stent restenosis seven female New Zealand rabbits underwent balloon dilation and denudation prior to stenting the abdominal aorta. After six weeks on atherogenic diet, animals were killed and the aorta was perfused with contrast agent. Micro-CT morphometric analysis of balloon and stent injured arteries obtained by 700 transverse sections (voxel size 10 μm) was compared to conventional histological analysis. Results: Intimal hyperplasia was present in stented and balloon injured arteries with a moderate intimal area assessed by Micro-CT and conventional histology (3.91±0.5 mm 2 vs. 4.18±0.42; r=0.9). High significant correlations between Micro-CT image analysis and conventional histomorphometry were obtained for lesion size, size of media, size of lumen and stent area (r=0.84 to 0.96). Conclusion: Micro-CT is feasible for quantitative information about restenosis following balloon angioplasty and stent implantation and has the potential to become a standard technique in many laboratories which will augment serial histology as the reference method for ex-vivo studies of restenosis. (orig.)

  14. The Incidence and Risk Factors of In-Stent Restenosis for Vertebrobasilar Artery Stenting.

    Science.gov (United States)

    Zheng, Dai; Mingyue, Zhu; Wei, Shi; Min, Li; Wanhong, Chen; Qiliang, Dai; Yongjun, Jiang; Xinfeng, Liu

    2018-02-01

    In-stent restenosis (ISR) remains a challenge for vertebrobasilar artery stenting (VBAS). We aimed to investigate the incidence and risk factors of ISR. This was a retrospective study. From July 28, 2005, to July 30, 2015, patients who received VBAS with an angiographic follow-up time of 6 to 12 months after surgery were enrolled. The clinical and angiographic issues were recorded and analyzed. In total, 283 patients with 335 stents were incorporated into the study. Vertebral ostial lesions accounted for 73.4% (246/335) of the lesions. During the follow-up period, 58 patients with 60 stents experienced ISR (>50%). Stepwise logistic regression analysis showed that the degree of residual stenosis, stent diameter, and alcohol consumption were independent predictors of ISR. Our study demonstrated the incidence and risk factors of ISR after VBAS. This retrospective study with the largest cohort to date provided insight into the occurrence of ISR after VBAS. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A new kind of 32P stent used for prevention of the restenosis after PTCA in rabbit iliac arteries

    International Nuclear Information System (INIS)

    Gao Dongsheng; Chen Runfen; Mao Jialiang; Huang Dingjiu

    2003-01-01

    Objective: To evaluate the effect and the mechanism of a new kind of 32 P stents used for prevention of the restenosis after percutaneous transluminal coronary angioplasty (PTCA); to observe the 'edge effect' caused by radioactive stents. Methods: Six 32 P-β-emitting stents made by compound plating, paired with 6 31 P nonradioactive(control) stents, were placed separately, one in one iliac artery in 6 rabbits, respectively. Animals were sacrificed after 30 d. Angiography, morphometry and immunohistochemistry work-up were performed. Results: There were no aneurysm or thrombosis in the arteries with stents placed. Morphometric measurements demonstrated that the mean minimum lumen diameter (MLD) was greater in 32 P stents than that in control stents (P 32 P stents was greater than that in control stents, but the later had marked neointimal area than the former (P 32 P-β-emitting stents made by compound plating could prevent in-stent restenosis significantly by inhibiting the neointimal growth even with low radioactivity; and it is safe, cheap and easy to make. But an unexpected increase in neointimal response, the so-called 'edge effect', was observed in the study

  16. Drug eluting stents and modern stent technologies for in-stent restenosis.

    Science.gov (United States)

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  17. Risk factors for in-stent restenosis of vertebral artery origin after stent implantation: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    Fang-fang HAO

    2018-01-01

    Full Text Available Objective To systematically review the risk factors for in-stent restenosis (ISR of vertebral artery origin after sent implantation to provide theoretical foundation for clinical prevention and treatment. Methods Taking vertebral artery, vertebrobasilar insufficiency, stents, drug-eluting stents, self expandable metallic stents in English and Chinese as key words, retrospective clinical studies about risk factors for ISR of vertebral artery origin were searched by using PubMed, EMBASE/SCOPUS, Cochrane Library, China Biology Medicine (CBM, China National Knowledge Infrastructure (CNKI, Wanfang Data and VIP database from January 1, 1966 to March 30, 2017. Quality assessment and Meta-analysis were made by using Newcastle-Ottawa Scale (NOS and Stata 12.0 software. Results The research enrolled 3468 articles in all, from which 11 studies were chosen after excluding duplicates and those not meeting the inclusion criteria. A total number of 1352 patients were divided into ISR group (N = 440 and non-ISR group (N = 912. The ISR incidence rate of smokers was significantly higher than non-smokers (OR = 2.179, 95%CI: 1.373-3.458; P = 0.001. The differences of bare metal stents (BMS utilization rate (OR = 2.072, 95% CI: 1.560-2.753; P = 0.000 and drug-eluting stents (DES utilization rate (OR = 0.483, 95% CI: 0.363-0.641; P = 0.000 between ISR group and non-ISR group were statistically significant. Conclusions Smoking and using BMS are risk factors for ISR of vertebral artery origin, and using DES is protective factor. Due to limited study quality, more high-quality studies are needed to verify this conclusion. DOI: 10.3969/j.issn.1672-6731.2017.12.004

  18. Influence of a pressure gradient distal to implanted bare-metal stent on in-stent restenosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Thuesen, Leif

    2007-01-01

    pullback recording in the entire length of the artery. METHODS AND RESULTS: In 98 patients with angina pectoris, 1 de novo coronary lesion was treated with a bare-metal stent. After stent implantation, pressure wire measurements (P(d)=mean hyperemic coronary pressure and P(a)=mean aortic pressure) were......-stent restenosis after 9 months. CONCLUSIONS: A residual abnormal P(d)/P(a) distal to a bare-metal stent was an independent predictor of in-stent restenosis after implantation of a coronary bare-metal stent. Udgivelsesdato: 2007-Dec-11......BACKGROUND: Fractional flow reserve predicts cardiac events after coronary stent implantation. The aim of the present study was to assess the 9-month angiographic in-stent restenosis rate in the setting of optimal stenting and a persisting gradient distal to the stent as assessed by a pressure wire...

  19. Clinical effectiveness of secondary interventions for restenosis after renal artery stenting

    Science.gov (United States)

    Simone, Thomas A.; Brooke, Benjamin S.; Goodney, Philip P.; Walsh, Daniel B.; Stone, David H.; Powell, Richard J.; Cronenwett, Jack L.; Nolan, Brian W.

    2013-01-01

    Objective Secondary interventions for renal artery restenosis (RAS) after renal artery stenting are common, despite limited data about their effectiveness. This study was designed to evaluate the outcomes of endovascular treatment of recurrent RAS. Methods We conducted a retrospective review of patients who underwent renal artery stenting between 2001 and 2011 at Dartmouth-Hitchcock Medical Center. Patients who required secondary interventions were compared with control patients who underwent only primary interventions for RAS. Multivariate regression models were used to identify factors associated with successful outcomes, as measured by changes in blood pressure, estimated glomerular filtration rate, and number of antihypertensive medications required. Results Sixty-five secondary (57 patients) renal interventions were undertaken for recurrent RAS associated with progressive hypertension or renal dysfunction and compared with outcomes after 216 primary (180 patients) renal artery stenting procedures. Patients undergoing primary vs secondary interventions did not differ significantly in the number of preoperative antihypertensive medications used, comorbid conditions, or blood pressure. All primary and secondary interventions were performed with stents and showed no difference in procedural complications. At a mean follow-up of 23 months (range, 1–128 months), similar improvements in renal function and blood pressure were found between patients undergoing primary and secondary interventions, and there was no difference in rates of restenosis or survival between cohorts. Regression models showed that the use of embolic protection devices was associated with improved renal function after primary (odds ratio [OR], 2.0; 95% confidence interval [CI], 1.1–3.8; P < .05) and secondary (OR, 4.7; 95% CI, 1.7–12.5; P < .05) interventions, whereas statin therapy was associated with improved renal (OR, 2.0; 95% CI, 1.3–3.2; P < .05) and blood pressure response (OR, 4

  20. Engineering Radioactive Stents for the Prevention of Restenosis

    International Nuclear Information System (INIS)

    Bruce Thomadsen; Nickles, Robert J.; Larry DeWerd; Douglass Henderson; Jonathan Nye; Wes Culberson; Stephen Peterson; Michael Meltsner; Liyong Lin

    2004-01-01

    Radiation has become an accepted treatment for the prevention of restenosis (re-blockage) of coronary arteries following angioplasty. Radioactive stents could be the easiest method of delivery for the radiation, although clinical trials were disappointing. One likely reason was the choice of P-32 as the radionuclide, which fails to match the biological needs of the problem. What radionuclide would perform best remains unknown. This project established the physical infrastructure necessary for a rational investigation to determine the optimum radiological characteristics for radioactive stents in the prevention of restenosis following angioplasty. The project investigated methods to activate coronary stents with radionuclides that spanned a range of energies and radiation types that could provide a mapping of the biological response. The project also provided calibration methods to determine the strength of the stents, an a process to calculate the dose distribution actually delivered to the patient's artery--quantities necessary for any future scientific study to improve the effectiveness of radioactive stents. Such studies could benefit the thousands of patients who receive angioplasty each year

  1. Recurrence of Subacute Stent Thrombosis and In-Stent Restenosis during Five Months after Stent Implantation in the LAD. A Case Report.

    OpenAIRE

    島田, 弘英; 大和, 眞史; 櫻井, 俊平; 疋田, 博之; 池田, 修一

    2001-01-01

    A coronary stent was deployed in the left anterior descending artery of an 82-year-old woman with unstable angina.Recurrence of subacute stent thrombosis and in-stent restenosis occurred frequently during the five months after initial stent implantation.Balloon angioplasty and cutting balloon angioplasty failed to prevent these complications,but they ceased after re-stenting in the initial stent.In this case,tissue protrusion through the stent strut, deformation of the coil stent and inadequa...

  2. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation

    DEFF Research Database (Denmark)

    Thayssen, Per; Jensen, Lisette Okkels; Lassen, Jens Flensted

    2012-01-01

    Aims: Data are limited on the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with coronary stents. We examined the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with percutaneous coronary intervention (PCI). Methods and results......: All patients who underwent stent implantation from 2002 to 2005 were identified in the Western Denmark Heart Registry. The hazard ratio (HR) for death associated with stent thrombosis or in-stent restenosis was estimated with a Cox regression analysis with stent thrombosis or in-stent restenosis...... as time-dependent variables. A total of 12,277 patients were treated with stent implantation. Stent thrombosis was observed in 111 (0.9%) patients and in-stent restenosis in 503 (4.1%) patients within 12 months after the index PCI. Occurrence of stent thrombosis was associated with an increased risk...

  3. Diagnostic value of microRNA-143 in predicting in-stent restenosis for patients with lower extremity arterial occlusive disease

    OpenAIRE

    Yu, Zhi-Hai; Wang, Hai-Tao; Tu, Can

    2017-01-01

    Purpose This study was conducted to explore the diagnostic value of microRNA-143 (miRNA-143) in predicting in-stent restenosis (ISR) of lower extremity arterial occlusive disease (LEAOD). Methods From February 2012 to March 2015, 165 patients (112 males and 53 females) with LEAOD undergoing interventional treatment were enrolled in this study. Serum miRNA-143 expression was detected using quantitative real-time polymerase chain reaction (qRT-PCR). Patients were assigned into the restenosis an...

  4. Results of a randomized clinical trial of external beam radiation to prevent restenosis after superficial femoral artery stenting.

    Science.gov (United States)

    Therasse, Eric; Donath, David; Elkouri, Stéphane; Lespérance, Jacques; Giroux, Marie-France; Oliva, Vincent L; Guertin, Marie-Claude; Bouchard, Louis; Perreault, Pierre; Gilbert, Patrick; Soulez, Gilles

    2016-06-01

    The objective of this study was to evaluate the safety and efficacy of external beam radiation (EBR) in preventing restenosis after superficial femoral artery (SFA) stenting in comparison with a control group treated with SFA stenting only. In this Institutional Review Board-approved study, patients who provided written informed consent were randomly assigned to 0 Gy or 14 Gy of EBR to the stent site 24 hours after SFA stenting. The primary end point was the angiographic binary restenosis rate 2 years after stenting. Categorical and continuous end points were respectively analyzed using logistic regression models and Wilcoxon tests. End points expressed as time to event were analyzed using a log-rank test. The study included 155 patients, 46 women and 109 men (mean age, 66 years; range, 45-85 years). In the 0 and 14 Gy groups, binary restenosis was present, respectively, in 44% (34/77) and 68% (52/76; P = .003) 2 years after stenting. Stent thrombosis occurred in 13% (10/78) of the 0 Gy group and in 33% (25/77) of the 14 Gy group (P = .003). Target lesion revascularization at 2 years was 26% (25/78) in the 0 Gy group and 30% (23/77) in the 14 Gy group (P = .56). There were no significant differences in total walking distances change from baseline to 2 years (46 ± 100 and 26 ± 79 m, respectively, in the 0 Gy and 14 Gy group; P = .25). There were no procedure-related deaths and no major amputations. A single 14 Gy dose of EBR to the SFA stenting site did not prevent in-stent restenosis. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-04-15

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis.

  6. Time-dependent 3D simulations of the hemodynamics in a stented coronary artery

    International Nuclear Information System (INIS)

    Faik, Isam; Mongrain, Rosaire; Leask, Richard L; Rodes-Cabau, Josep; Larose, Eric; Bertrand, Olivier

    2007-01-01

    Stenting is becoming the major interventional cardiology procedure worldwide. However restenosis remains a major limitation to the effectiveness of stents. Alterations to the local hemodynamics in the stented segment of the artery could be a potential factor in the development of in-stent restenosis. The characterization of wall shear stress and of blood flow patterns in a stented artery is therefore necessary for a good understanding of the role of hemodynamics in the development of in-stent restenosis. We have used a time-dependent 3D numerical model of a stented coronary artery to study the characteristics of the blood flow and the shear stress distribution. Our results show that the presence of the stent produces significant secondary flow that is limited to an annulus in the near wall region. Low shear stress zones were localized in the vicinity of the struts while the tips of the struts exhibited high values of shear stress. These results support the hypothesis that local hemodynamics may affect the development of in-stent restenosis and could influence the choice of stent geometries for future stent designs

  7. Cryoplasty for the Prevention of Arterial Restenosis

    International Nuclear Information System (INIS)

    Wildgruber, Moritz G.; Berger, Hermann J.

    2008-01-01

    Restenosis after percutaneous transluminal angioplasty remains the limiting factor for the long-term benefit of endovascular therapies of peripheral arterial occlusive disease. Despite a variety of modifications and adjuncts to angioplasty such as bare metal stents, covered stents, and drug-eluting stents as well as a number of new technologies like laser angioplasty and cutting balloon angioplasty, restenosis rates have not been significantly affected and remain inferior to those for surgery for long lesions in the femoropopliteal segment. Cryoplasty, which combines balloon angioplasty with the application of cryothermal energy to the vessel wall, was suggested as a promising approach to prevent the formation of neointimal hyperplasia after angioplasty procedures. This review discusses the basic principles of cryoplasty, summarizes the current data on restenosis rates after cryoplasty treatment, and evaluates cryoplasty as a new treatment method to solve the problems associated with restenosis development. The results of the clinical studies suggest that cryoplasty is a feasible and safe technique in the treatment of femoropopliteal disease, however, they have failed to prove any superiority of cryoplasty over conventional angioplasty.

  8. Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis

    International Nuclear Information System (INIS)

    Kim, D. E.; Park, S. A.; Kim, C. K.; Chang, J. A.; Jeong, J. W.; Oh, S. G.; Lee, C.

    2007-01-01

    It appears logical that myocardial perfusion should be fixed and not reversible, in the territory supplied by a dilated coronary artery. However, several studies have demonstrated reversible perfusion in the territory supplied by a coronary artery with an optimally implanted stent. The main objective of this study was to evaluate the incidence of reversible defects detected by M-SPECT early after optimal PTCA with stent implantation. Its second objective was to determine the predictive value of detecting reversible defects after stent implantation for late restenosis. Sixty-six patients that underwent M-SPECT within 24 hours of successful PTCA with stent implantation were included. All patients were followed up clinically and angiographically. The incidence of reversible perfusion defects on M-SPECT and the rate of late restenosis in target coronary arteries were evaluated retrospectively. Reversible perfusion defects on M-SPECT were observed in 26% of the patients and in 36% of lesions following successful PTCA with stent implantation. The incidence of late restenosis was significantly higher in patients and lesions with reversible perfusion defects (47% vs. 18%). According to binary logistic regression analysis, the presence of a reversible perfusion defects was the only independent predictor of late restenosis. This study shows that the predictive value of reversible perfusion defects on M-SPECT early after stent implantation with respect to the incidence of late restenosis was 47% in patients with a reversible defect, and 18% in those without it

  9. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  10. A Mechanobiological model for damage-induced growth in arterial tissue with application to in-stent restenosis

    Science.gov (United States)

    Fereidoonnezhad, B.; Naghdabadi, R.; Sohrabpour, S.; Holzapfel, G. A.

    In-stent restenosis (ISR) is one of the main drawbacks of stent implementation which limits the long-term success of the procedure. Morphological changes occurring within the arterial wall due to stent-induced mechanical injury are a major cause for activation of vascular smooth muscle cells (VSMCs), and the subsequent development of ISR. Considering the theory of volumetric mass growth and adopting a multiplicative decomposition of the deformation gradient into an elastic part and a growth part, we present a mechanobiological model for ISR. An evolution equation is developed for mass growth of the neointima, in which the activation of VSMCs due to stent-induced damage (injury) and the proliferation rate of the activated cells are considered. By introducing the mass evolution into the mass balance equation, we obtain the evolution of the growth tensor over time. The model is implemented in a finite element code and the procedure of angioplasty is simulated, whereby the features of the proposed growth model are illustrated.

  11. Modelling and simulating in-stent restenosis with complex automata

    NARCIS (Netherlands)

    Hoekstra, A.G.; Lawford, P.; Hose, R.

    2010-01-01

    In-stent restenosis, the maladaptive response of a blood vessel to injury caused by the deployment of a stent, is a multiscale system involving a large number of biological and physical processes. We describe a Complex Automata Model for in-stent restenosis, coupling bulk flow, drug diffusion, and

  12. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  13. Coated stents to prevent restenosis in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2005-11-01

    Full Text Available Background: In-stent-restenosis (ISR is considered to be an essential limiting factor of stenting in coronary heart disease (CHD. The development of coated stents has raised expectations on substantial lowering restenosis after stenting with decreasing the rate of restenosis and a reduction in the rate of clinical events. Objectives: The present analysis addresses the questions on medical effectiveness and cost-effectiveness of the use of various coated stent types in CHD. Methods: The literature was searched in December 2004 in the most relevant medical and economic databases. The medical evaluation was conducted on the basis of published RCT. The data from the studies regarding various angiographic, sonographic and clinical endpoints were checked for methodical quality and summarised in meta-analyses. Within the scope of economic evaluation the primary studies were analysed and modelling was performed, applying clinical effect estimates from the meta-analyses of the medical evaluation and current estimates of German costs. Results: Medical evaluation: Ten different stenttypes were used in the included 26 RCT. The results for heparin, silicon-carbide, carbon and PTFE coated stenttypes could not reveal any significant differences between the medical effectiveness of coated and uncoated stents. The application of sirolimus, paclitaxel, everolimus and 7-hexanoyltaxol eluting stents showed a significant lower restenosis at 6-9 months with decrease in the rate of restenosis for polymer-based sirolimus, paclitaxel and 7-hexanoyltaxol eluting stents. In contrast, the use of gold-coated and actinomycin-D eluting stents was associated with a significantly higher restenosis. The polymer-based sirolimus and paclitaxel eluting stents also showed a significant and considerable reduction in the rate of repeated percutaneous revascularisations at 6-12 months (3.5% vs. 19.7%; p<0.0001, RR=0.19 [95%CI: 0.11; 0.33] and 3.5% vs. 12.2%; p<0.0001, RR=0.30 [95%CI: 0

  14. Renal artery stent fracture with refractory hypertension: a case report and review of the literature.

    Science.gov (United States)

    Chua, Su-Kiat; Hung, Huei-Fong

    2009-07-01

    A 73-year-old man with resistant hypertension and impaired renal function underwent stenting for right renal artery (RRA) stenosis. Two years later, he presented with uncontrolled hypertension and worse renal function. Renal arteriogram revealed RRA stent fracture with in-stent restenosis. Another stent was deployed. Four months later, however, renal arteriogram revealed in-stent restenosis again. This time, balloon angioplasty alone was performed. He had been symptom-free with stable condition at 2-year follow-up. A literature review disclosed six renal artery stent fracture cases, including the present one, who developed in-stent stenosis resulted from stent fracture. Two major anatomy features of renal artery stenosis were suggestive for development of stent fracture: (1) renal artery entrapment by diaphragmatic crus, and (2) mobile kidney with acute angulation at proximal segment of the renal artery. It is important to detect this etiology of renal artery stenosis because stenting in these vessels may contribute to in-stent restenosis or stent fracture. Management of renal artery stent fracture, including endovascular treatment or aortorenal bypass, should be considered on a case-by-case basis in relation to clinical settings. Copyright 2009 Wiley-Liss, Inc.

  15. Angiographic follow-up after carotid artery stenting of bifurcation stenosis; Angiographische Verlaufskontrolle nach Stentimplantation zur Behandlung der Karotisbifurkationsstenose

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, E.A.; Forsting, M. [Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitaetsklinik Essen (Germany); Jansen, C.; Drescher, R.; Mathias, K. [Radiologische Klinik, Klinikum Dortmund (Germany); Schwarz, M. [Neurologische Klinik, Klinikum Dortmund (Germany); Christmann, A. [Fachbereich Statistik, Univ. Dortmund (Germany); Jaeger, H. [Radiologische Klinik, Klinikum Dortmund (Germany); Marien-Hospital Wesel, Praxis fuer Radiologie, Neuroradiologie and Nuklearmedizin (Germany)

    2006-08-15

    Purpose: the purpose of this prospective study was to determine the restenosis grade, the intima hyperplasia and the stent expansion via angiographic follow-up six months after carotid artery stenting. Materials and methods: in 100 patients, angiographic follow-up was performed 5.9 months (range: 2.9 - 11.4 months) after carotid artery stenting. The restenosis grade, the intima hyperplasia and the stent expansion were measured by selective angiography of the treated carotid artery. Results: the mean restenosis grade was 16% (range: 0 - 78%). In 6 of 100 patients (6%), a restenosis grade of > 50% was measured. In 4 patients the restenosis grade was 50 - 70%. In 2 patients the restenosis grade was > 70%. In 91 of 100 patients (91%), the restenosis was localized in the former area of stenosis of the carotid artery, and in 9 of 100 patients (9%), the restenosis was localized in the cranial stent end. The mean grade of intima hyperplasia was 31% (range: 2 - 70%). The mean increase in stent expansion at the time of follow-up was 10% (range: 0 - 59%). No correlation was able to be determined between the grade of stenosis and the grade of restenosis (rho = 0,017, range: -0.180 - 0.213), between the grade of residual stenosis and the grade of restenosis (rho = 0,257, range: 0.064 - 0.431) and between intima hyperplasia and the grade of restenosis (rho = 0,476, range: 0.309 - 0.615). Conclusions: carotid artery stenting is associated with a low incidence of high-grade restenosis 6 months after an intervention. The intima hyperplasia, which can be observed in each Wallstent, is partly compensated by the expansion of the self-expandable stent. Without a correlation between the grade of residual stenosis and the grade of restenosis, low-grade residual stenosis can be accepted. Therefore, we recommend undersized postdilation of the Wallstent. (orig.)

  16. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    Directory of Open Access Journals (Sweden)

    Geanina Onuta

    2011-01-01

    Full Text Available Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s of long-term autoimmune diabetes on development of in-stent restenosis. We here describe the development of in-stent restenosis in long-term (~7 months spontaneously diabetic and age-matched, thymectomized, nondiabetic Diabetes Prone BioBreeding (BBDP rats (n=6-7 in each group. Diabetes was suboptimally treated with insulin and was characterized by significant hyperglycaemia, polyuria, proteinuria, and increased HbA1c levels. Stented abdominal aortas were harvested 28 days after stenting. Computerized morphometric analysis revealed significantly increased neointima formation in long-term diabetic rats compared with nondiabetic controls. In conclusion, long-term autoimmune diabetes in BBDP rats enhances in-stent restenosis. This model can be used to study the underlying pathogenetic mechanisms of diabetes-enhanced in-stent restenosis as well as to test new therapeutic modalities.

  17. Stenting versus endarterectomy for restenosis following prior ipsilateral carotid endarterectomy : An individual patient data meta-analysis

    NARCIS (Netherlands)

    Fokkema, Margriet; Vrijenhoek, Joyce E P; Ruijter, Hester M Den; Groenwold, Rolf H H; Schermerhorn, Marc L.; Bots, Michiel L.; Pasterkamp, Gerard; Moll, Frans L.; De Borst, Gert Jan

    2015-01-01

    Objective: To study perioperative results and restenosis during follow-up of carotid artery stenting (CAS) versus carotid endarterectomy (CEA) for restenosis after prior ipsilateral CEA in an individual patient data (IPD) metaanalysis. Background: The optimal treatment strategy for patients with

  18. Prosthetic bypass for restenosis after endarterectomy or stenting of the carotid artery.

    Science.gov (United States)

    Illuminati, Giulio; Belmonte, Romain; Schneider, Fabrice; Pizzardi, Giulia; Calió, Francesco G; Ricco, Jean-Baptiste

    2017-06-01

    The objective of this study was to evaluate the results of prosthetic carotid bypass (PCB) with polytetrafluoroethylene (PTFE) grafts as an alternative to carotid endarterectomy (CEA) in treatment of restenosis after CEA or carotid artery stenting (CAS). From January 2000 to December 2014, 66 patients (57 men and 9 women; mean age, 71 years) presenting with recurrent carotid artery stenosis ≥70% (North American Symptomatic Carotid Endarterectomy Trial [NASCET] criteria) were enrolled in a prospective study in three centers. The study was approved by an Institutional Review Board. Informed consent was obtained from all patients. During the same period, a total of 4321 CEAs were completed in the three centers. In these 66 patients, the primary treatment of the initial carotid artery stenosis was CEA in 57 patients (86%) and CAS in nine patients (14%). The median delay between primary and redo revascularization was 32 months. Carotid restenosis was symptomatic in 38 patients (58%) with transient ischemic attack (n = 20) or stroke (n = 18). In this series, all patients received statins; 28 patients (42%) received dual antiplatelet therapy, and 38 patients (58%) received single antiplatelet therapy. All PCBs were performed under general anesthesia. No shunt was used in this series. Nasal intubation to improve distal control of the internal carotid artery was performed in 33 patients (50%), including those with intrastent restenosis. A PTFE graft of 6 or 7 mm in diameter was used in 6 and 60 patients, respectively. Distal anastomosis was end to end in 22 patients and end to side with a clip distal to the atherosclerotic lesions in 44 patients. Completion angiography was performed in all cases. The patients were discharged under statin and antiplatelet treatment. After discharge, all of the patients underwent clinical and Doppler ultrasound follow-up every 6 months. Median length of follow-up was 5 years. No patient died, sustained a stroke, or presented with a

  19. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    International Nuclear Information System (INIS)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D.; Zeller, Thomas; Coerper, Stephan; Beckert, Stefan; Balletshofer, Bernd

    2007-01-01

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 ± 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  20. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  1. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  2. Study on the application of big cup membranate stent on restenosis after stenting for carcinoma of esophago cardia

    International Nuclear Information System (INIS)

    Wang Xiuping; Yao Zhongqiang; Liu Jian; Zhang Yan

    2007-01-01

    Objective: To evaluate the clinical value of self-designed big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia. Methods: 12 cases of restenosis after stenting for carcinoma of esophago-cardia were involved in the study. Self-designed big cup membranate stent made by Nanjing Weichuang Company (the length of the cup was 3.5 cm)was placed into the constricted stent under guidance of fluoroscopy. Clinical effect, restenosis, and complications were observed during followed up. Results: All the 12 cases of big cup membranat stent placement went along smoothly without indigitation of the cup of the stent. Follow-up of 1.5-8 months showed that 2 cases developed severe restenosis on the big cup of the stem, resulting in third grade difficult deglutition. Among them, one occurred 1 month after stenting, caused by hyperplasia of large amount of granulation tissue; another occurred 6 months after stenting, caused by growth of tumor tissue. 3 cases developed mild to moderate restenosis, 2.3-7 months (mean: 4.6 months) after stenting, with result of first grade difficult deglutition. The remaining 7 cases (mean 5.6 months follow-up) did not have difficulty during deglutition. Conclusions: Application of big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia can effectively prevent the stent from moving downwards and thus lower down the rate of restenosis, and postpone the occurrence of restenosis. (authors)

  3. Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Benjamin Bondue

    2016-01-01

    Full Text Available Endoscopic treatment of a bronchial restenosis previously treated by insertion of a partially covered self-expandable metallic stent (SEMS can be difficult. Classically, after recanalization of the bronchus, the stent is removed and replaced by a more adapted one. We report on two cases of proximal bronchial restenosis treated by insertion of an additional stent inside the lumen of the previously inserted stent using the stent-in-stent (SIS technique. The indications for the initial stent were malignancy in Patient 1 and posttransplant bronchial stenosis in Patient 2. Restenosis occurred at the proximal end of the stent within months in both cases. Stent removal and insertion of a new stent were considered, but this option was discarded because of an excessive risk of bronchial perforation and preference towards an alternative approach. In both cases, a second customized SEMS was placed using the SIS technique after ablation of the proximal end stenosis of the stent by argon plasma coagulation and/or dilation with a balloon. Recanalization of the bronchus was achieved in both cases without complications. The SIS technique is a valuable alternative to removal of SEMS in case of proximal bronchial restenosis.

  4. A Phase II study of external-beam radiotherapy and endovascular brachytherapy with PTA and stenting for femoropopliteal artery restenosis

    International Nuclear Information System (INIS)

    Narayan, Kailash; Denton, Michael; Das, Ram; Bernshaw, David; Rolfo, Aldo; Dyk, Sylvia van; Mirakian, Alex

    2006-01-01

    Purpose: To assess the safety and seek evidence of efficacy of combined external-beam radiotherapy (EBRT) and endovascular brachytherapy in the treatment of stenotic vascular lesions. Methods and Materials: Seventeen patients with high risk for restenosis of femoropopliteal arteries were enrolled in this study from February 2000 to August 2002. The external beam radiotherapy regimen consisted of 10 Gy in 5 fractions of 2 Gy, starting on Day 0. This was followed on Day 6 by angiography, stent placement, and intraluminal brachytherapy to a dose of 10 Gy at 1.2 mm from stent surface. The EBRT was continued from the same day to another 10 Gy in 2 Gy daily fractions for 5 days. Results: The follow up ranged from 33 months to 60 months. At the time of analysis 15 of 17 patients were alive with patent stents. Of these, 10 were symptom-free. Two patients died of unrelated causes. Conclusions: The combination of EBRT and endovascular brachytherapy provided adequate dose distribution without any geographical miss or 'candy wrapper' restenosis. No incidence of aneurysmal dilation of radiated vascular segment was observed. The treatment was feasible, well tolerated, and achieved 88% stenosis free survival

  5. Microwave Spectrometry for the Assessment of the Structural Integrity and Restenosis Degree of Coronary Stents

    Science.gov (United States)

    Arauz-Garofalo, Gianluca; Lopez-Dominguez, Victor; Garcia-Santiago, Antoni; Tejada, Javier; O'Callaghan, Joan; Rodriguez-Leor, Oriol; Bayes-Genis, Antoni; Gmag Team; Hugtp Team; Upc Team

    2013-03-01

    Cardiovascular disease is the main cause of death worldwide. Coronary stents are one of the most important improvements to reduce deaths from cardiovascular disorders. Stents are prosthetic tube-shaped devices which are used to rehabilitate obstructed arteries. Despite their obvious advantages, reocclusion occurs in some cases arising from restenosis or structural distortions, so stented patients require chronic monitoring (involving invasive or ionizing procedures). We study microwave scattering spectra (between 2.0 - 18.0 GHz) of metallic stents in open air, showing that they behave like dipole antennas in terms of microwave scattering. They exhibit characteristic resonant frequencies in their microwave absorbance spectra that are univocally related to their length and diameter. This fact allows one to detect stent fractures or collapses. We also investigate the ``dielectric shift'' in the frequency of the resonances mentioned above due to the presence of different fluids along the stent lumen. This shift could give us information about the restenosis degree of implanted stents.

  6. Renal artery stent angioplasty for renovascular hypertension

    International Nuclear Information System (INIS)

    Li Gang; Li Haiqing; Wang Lin

    2005-01-01

    Objective: To evaluate the therapeutic results of expandable stent for treatment of atherosclerotic renovascular obstructive disease. Methods: 15 patients (10 men and 5 women, 41-75 years old; mean age, 52 years) with renal arterial hypertension underwent renal stent angioplasty including renal arterial stenosis 89%(n=13) and fully obstruction without function in 2, of which 2 patients had bilateral involvement. The stenotic range of all arterial segments showed 60% to 90% width of the normal arterial diameter. 16 stents were implanted under the guidance of fluoroscopy. The most of stents implanted were Palmaz (n=12, 75%) with regular clinical and angiographic follow up. Results: Technical success (residual stenosis <30%) was achieved in all patients without serious complication. During the follow-up (6-15 months; mean, 8 ± 4 months), hypertension was improved in 9 patients and cured in 4 patients with a total benefit of 86% and no efficacy in 2(13%). The average systolic blood pressure decreased from 27.12 ± 3.09 kPa to 18.62 ± 3.12 kPa and the average diastolic blood pressure decreased from 17.73 ± 1.92 kPa to 11.12 ± 2.43 kPa after stent treatment (P<0.05). Serum creatinine remained stable in 60% (n=9) patients with improvement in 33% (n=5) and worsened in 6% (n=1) patients. Follow-up angiography was performed in all patients with 1 case of a restenosis. 6 months after expanding through stent by using balloon, the two follow up angiographies showed a stable restenosis about 20%. Conclusions: Percutaneous transluminal stent placement is highly beneficial for patients who had renal arterial obstructive disease. The success of stent angioplasty of complete obstructive renal arteries reveals wide prospects for interventional method. (authors)

  7. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  8. Directional atherectomy for treatment of restenosis within coronary stents: clinical, angiographic and histologic results

    NARCIS (Netherlands)

    B.H. Strauss (Bradley); V.A.W.M. Umans (Victor); R-J. van Suylen (Robert-Jan); P.J. de Feyter (Pim); J. Marco (Jean); G. Robertson; J. Renkin; G.R. Heyndrickx (Guy); V.D. Vuzevski (Vojislav); F.T.B. Bosman (Fré); P.W.J.C. Serruys (Patrick)

    1992-01-01

    textabstractAbstract OBJECTIVES: The safety and long-term results of directional coronary atherectomy in stented coronary arteries were determined. In addition, tissue studies were performed to characterize the development of restenosis. METHODS: Directional coronary atherectomy was performed in

  9. The Role Of Inflammation In Stent Restenosis More Than 1 Year Afetr Drug Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Hasan Shemirani

    2011-09-01

    Full Text Available Background: In stent restenosis (ISR following endovascular interventions is the main limitation of their long-term success. Despite advances have been made during recent years to decrease restenosis, it remains a challenging clinical problem.The aim of this study was to evaluate the relationship between angiographic coronary in stent restenosis, inflammation after successful stent implantation. Methods: This study included 78 patients, 35year old and higher who underwent coronary angiography more than 1 year after drug-eluting stent (DES implantation because of symptoms suggestive ischemia. Patients were divided into ISR group (case and patent stent group (control according to angiography results. For all patients blood lipids and high sensitivity C-Reactive Protein (hsCRP were measured simultaneously. Results: Age, sex, hypertension, current smoking, and lipid profile other than High Density Lipoprotein (HDL-C of patients in the case and control groups were similar .However, HDL-C < 40mg/L was more prevalent with ISR (66.7% vs. 30.8%, p=0.002. The hsCRP level was 2.98±2.06 mg/L in the case group and 2.50±1.80 mg/L in the control group. There were no significant differences in mean hsCRP concentration between the two groups (p=0.14, however mean hsCRP level was significantly higher in men of case group than control group (3.35mg/L vs. 2.21mg/L, p<0.05. Conclusion: This study demonstrates that in men but not in women inflammation may be a predictor of in stent restenosis more than 1 year after drug eluting stent implantation. Also, high-density lipoprotein (HDL probably has protective effect against stent restenosis.

  10. Restenosis Prevention Using Photon External Beam Radiation

    International Nuclear Information System (INIS)

    Goldstein, M.

    2002-01-01

    During transluminal coronary angioplasty, the balloon procedure is designed to crush the plaque and to support the weakened arterial wall by using the stent (an expandable metallic mesh). This procedure often tears the arterial wall as well. Some of the cells in the blood vessel respond to this injury by initiating repair which often leads to restenosis (reclosing) of the artery. In many cases restenosis occur despite the stent which become incorporated into the poliferative tissue that form around the lesion. But if the lesion is treated with radiation (8-30 Gy) the restenosis effect is inhibited. In this paper, the Adjoint Monte Carlo (AMC) method is used for external radiation treatment planning of the stent volume (the volume covered by the stent during a full cardiac cycle), while minimizing the damage to the organs at risk (OAR) and surrounding healthy tissue

  11. Symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) with concurrent contralateral vertebral atherosclerotic diseases in 88 patients treated with the intracranial stenting

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zi-Liang [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Gao, Bu-Lang [Department of Medical Research Shijiazhuang First Hospital, Hebei Medical University (China); Li, Tian-Xiao, E-mail: litianxiaod@163.com [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Cai, Dong-Yang; Zhu, Liang-Fu; Bai, Wei-Xing; Xue, Jiang-Yu; Li, Zhao-Shuo [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China)

    2015-09-15

    Highlights: • Symptomatic vertebral artery stenosis can be treated with intracranial stenting. • Stenting for intracranial vertebral artery stenosis is safe and effective. • Stenting for intracranial vertebral artery stenosis can prevent long-term stroke. - Abstract: Purpose: To investigate the safety, effect and instent restenosis rate of Wingspan stenting in treating patients with intracranial vertebral artery atherosclerotic stenosis (70–99%) concurrent with contralateral vertebral artery atherosclerotic diseases. Materials and methods: Eighty-eight patients with severe symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) combined with contralateral vertebral artery atherosclerotic diseases were treated with the Wingpsan stent. All the baseline, cerebral angiography, success rate, perioperative complications, clinical and imaging follow-up data were prospectively analyzed. Results: The success rate of stenting was 100%, and the mean stenotic rate was reduced from prestenting (84.9 ± 6.8)% to poststenting (17.2 ± 5.9)%. The perioperative stroke rate was 1.1%. Among eighty patients (90.9%) with clinical follow-up 8-62 months (mean 29.3 ± 17.2) poststenting, five (6.3%) had posterior circulation TIA only, three (3.8%) had mild stroke in the posterior circulation but recovered completely, and another five patients greater than 70 years old died of non-ischemic stroke. Imaging follow-up in 46 patients (52.3%) 5–54 months (mean 9.9 ± 9.9) following stenting revealed instent restenosis in 12 patients (26.1%) including 7 (58.3%) symptomatic restenosis. Age and residual stenosis were the two factors to significantly (P < 0.05) affect instent restenosis. Conclusion: Wingspan stenting in the intracranial vertebral artery atherosclerotic stenosis combined with contralateral vertebral artery atherosclerotic diseases has a low perioperative stroke rate and a good preventive effect on long-term ischemic stroke, but the instent restenosis

  12. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  13. Insertion of Self-Expandable Nitinol Stents Without Previous Balloon Angioplasty Reduces Restenosis Compared with PTA Prior to Stenting

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech

    2002-01-01

    Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome

  14. Factors that affect mass transport from drug eluting stents into the artery wall

    Directory of Open Access Journals (Sweden)

    Walsh Michael T

    2010-03-01

    Full Text Available Abstract Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy.

  15. An argument for the use of multiple segment stents in curved arteries.

    Science.gov (United States)

    Kasiri, Saeid; Kelly, Daniel J

    2011-08-01

    Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.

  16. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  17. Restenosis in coronary bare metal stents. Importance of time to follow-up: a comparison of coronary angiograms 6 months and 4 years after implantation

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Helqvist, Steffen; Kløvgaard, Lene

    2008-01-01

    Objectives. Angiographic late lumen loss measured 6 to 9 month after bare metal stent implantation in the coronary arteries is a validated restenosis parameter. Design. We performed a second angiographic follow-up after 4 years in event free survivors from the DANSTENT trial cohort. Results......-sectional vessel area and a 39% reduction of the binary restenosis rate over time. Conclusions. Instent late lumen loss in bare metal stents decreases spontaneously over time. Maturation of early hyperplastic tissue reaction after stent implantation with subsequent thinning of fibrotic tissue might explain...

  18. Clinical observation of intraluminal stent angioplasty in the treatment of renal arterial stenoses

    International Nuclear Information System (INIS)

    Lu Yanwen; Zhang Jian; Huang Xianglong

    2002-01-01

    Objective: To evaluate the clinical application of intraluminal stent angioplasty (PTRAS) in the treatment of renal arterial stenoses. Methods: A retrospective study was done in 28 patients with renal arterial stenoses. Primary renal artery stenting was performed in 28 consecutive patients (36 renal arteries). Blood pressure, serum creating, the number of anti-hypertensive medications were recorded at 1, 6, 12 month post stent angioplasty respectively. Arterial angiography was also taken 1 year later to evaluate the incidence of restenosis. Results: Technical success rate was 100% achieving in all patients without serious complications. Primary successful patently rate reached 82% (renal artery 86%), secondary successful rate was 89% (renal artery 90%). Systolic and diastolic blood pressure were reduced significantly (P<0.01) at 1,6,12 month after stent angioplasty comparing with baseline and clinical improvement (cured + improved) of hypertension reached 100%, 92.9%, 89.3% respectively. There were no significant differences between serum creatine level and the number of anti-hypertensive medications before and after stent angioplasty. One year later, 14.3% of all patients showed improvement of renal function, 64.3% remained in stabilization and 21.4% fell into deterioration. Angiographic restenosis was found in 3 cases one year after stent angioplasty. Complications included 1 hematoma at puncture site and 3 transient azotaemia. Conclusions: PTRAS can be performed safely with high technical success and beneficial to the majority of patients with hypertension or renal insufficiency and therefore it should be the first choice in treating renal arterial stenoses

  19. Endovascular brachytherapy to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Wohlgemuth, W.A.; Bohndorf, K.

    2003-01-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [de

  20. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    International Nuclear Information System (INIS)

    Chalmers, Nicholas; Walker, Paul T.; Belli, Anna-Maria; Thorpe, Anthony P.; Sidhu, Paul S.; Robinson, Graham; Ransbeeck, Mariella van; Fearn, Steven A.

    2013-01-01

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5–22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months’ follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  1. Mechanical thrombectomy using Rotarex system and stent-in-stent placement for treatment of distal femoral artery occlusion secondary to stent fracture – a case report and literature review

    International Nuclear Information System (INIS)

    Dys, Krzysztof; Drelichowska-Durawa, Justyna; Dołega-Kozierowski, Bartosz; Lis, Michał; Sokratous, Kyriakos; Iwanowski, Wojciech; Drelichowski, Stanisław; Witkiewicz, Wojciech

    2013-01-01

    Treatment of peripheral arterial diseases may be distinguished into conservative and interventional management; the latter is divided into surgical and endovascular procedures. Management of peripheral artery stenosis and occlusion with vascular stents is associated with the risk of late complications such as restenosis, stent fracture or dislocation. A 62-year-old woman with generalized atherosclerosis, particularly extensive in lower limb arteries, was admitted to the Department of Angiology 11 months after having an endovascular procedure performed due to critical ischemia of left lower limb. Because of stent occlusion, a decision to perform angiographic examination of lower limb arteries was made. Examination revealed occlusion of the superficial femoral artery along its entire length, including previously implanted stents. Distal stent was fractured with slight dislocation of the proximal segment. A decision was made to perform mechanical thrombectomy using a Rotarex system followed by a stent-in-stent placement procedure. Follow-up angiography and ultrasound scan performed 24 hours after the procedure revealed a patent vessel with satisfactory blood flow. Nowadays, imaging diagnostics of peripheral artery stenosis involves non-invasive examinations such as ultrasound, minimally invasive examinations such as angio-MRI and MDCT, or invasive examinations such as DSA and IVUS. DSA examinations are used to confirm significant stenosis or occlusion of a vessel, particularly when qualifying a patient for endovascular treatment. Due to their anatomic location, the superficial femoral artery and the popliteal artery are subject to various forces e.g. those exerted by the working muscles. Mechanical thrombectomy and atherectomy are efficient methods of arterial recanalization used in the treatment of acute, subacute or even chronic occlusions or stenosis of peripheral vessels. Frequency of angioplasty and vascular stent implantation procedures is increased in patients

  2. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  3. Genous endothelial progenitor cell-capturing stent system: a novel stent technology

    NARCIS (Netherlands)

    Klomp, Margo; Beijk, Marcel A. M.; de Winter, Robbert J.

    2009-01-01

    Drug-eluting stents have been demonstrated to significantly reduce clinical and angiographic restenosis in patients with coronary artery disease compared with bare-metal stents. Intuitively, however, a prohealing approach for the prevention of in-stent restenosis by promoting accelerated

  4. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Mayer, T.E. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Henkes, H. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Kis, B. [Department of Neurology, Alfried Krupp Hospital, Essen (Germany) and Department of Psychiatry and Psychotherapy, University of Duisburg-Essen, Virchow Street 174, D-45147 Essen (Germany)]. E-mail: bernhard.kis@uni-duisburg-essen.de; Hamann, G.F. [Department of Neurology, Klinikum Grosshadern, University of Munich (Germany); Holtmannspoetter, M. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Brueckmann, H. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Kuehne, D. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany)

    2005-11-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.

  5. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    International Nuclear Information System (INIS)

    Weber, W.; Mayer, T.E.; Henkes, H.; Kis, B.; Hamann, G.F.; Holtmannspoetter, M.; Brueckmann, H.; Kuehne, D.

    2005-01-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found

  6. Pulmonary Arterial Stent Implantation in an Adult with Williams Syndrome

    International Nuclear Information System (INIS)

    Reesink, Herre J.; Henneman, Onno D. F.; Delden, Otto M. van; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul

    2007-01-01

    We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent implantation. Short-term follow-up showed a good clinical result with excellent patency of the stents but early restenosis of the segments in which only balloon angioplasty was performed. These stenoses were subsequently also treated successfully by stent implantation. Stent patency was observed 3 years after the first procedure

  7. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    International Nuclear Information System (INIS)

    Sahin, Sinan; Cimsit, Cagatay; Andac, Nurten; Baltacioglu, Feyyaz; Tuglular, Serhan; Akoglu, Emel

    2006-01-01

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions

  8. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Sinan [Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Hospital, Department of Radiology, Istanbul (Turkey)]. E-mail: sinan.sahin@e-kolay.net; Cimsit, Cagatay [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Andac, Nurten [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Baltacioglu, Feyyaz [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Tuglular, Serhan [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey); Akoglu, Emel [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey)

    2006-01-15

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions.

  9. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  10. The Dresden in-stent restenosis radiation trial (DIRRT) with liquid-filled 188Re balloon

    International Nuclear Information System (INIS)

    Kropp, J.; Runge, R.R.; Reynen, K.; Koeckeritz, U.; Schmeisser, A.; Strasser, R.H.

    2002-01-01

    Full text: In some studies intracoronary radiation therapy (IRT) to minimize the restenosis rate after PTCA proved to be effective. We evaluated the performance, safety and effectiveness of IRT with 188 Re-perrhenate filled into a standard PTCA balloon. This kind of IRT allows a self-centering homogenous dose distribution to the vessel wall. 107 patients (pts) with a mean age of 63 years (81 m, 26 fin) with in-stent restenosis (type B in 39 %, type C in 61 %) and proven ischemia were included. After routine re-PTCA with or without additional stent implantation a second standard balloon was placed into the PTCA area and filled with β - -emitting liquid 188 Re at 3 atm. Irradiation time was 525 ± 167 sec to achieve a dose of 30 Gy at 0.5 mm depth of the vessel wall. In only one procedure there was a disconnection of the 188 Re containing system and the catheter but no contamination of the cath table or lab was measured. In 16 coronaries 21 stents were additionally implanted. In the follow-up 4 stent thromboses (1 day, 37 days, 2 x 6 months) with subsequent myocardial infarction were noticed, all in pts with additionally implanted stents. 57 pts had control angiography after 4 to 6 months after therapy and 41 after one year. Restenosis (stenosis > 50 % of luminal diameter) was shown in 9 out of 12 pts (75 %) with additionally implanted stents but only in 4 out of 24 pts (17 %) with PTCA alone. Reocclusion was noticed in 3 (25 %) pts with additional stent but only in 1 pt (4 %) without. No re-restenosis occurred in 20 patients which were without finding after 6 months. Intracoronary radiation therapy (IRT) with β - -emitting liquid-filled 188 Re balloon is a safe and effective therapy method which might be used routinely. Long-term results seem satisfactory in a patient group with in-stent restenosis and high risk of re-restenosis. But the positive effect of irradiation is abolished if an additional stent after PTCA is needed. (author)

  11. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  12. The experimental study of 32P and diallyl trisulfide coating stent for inhibiting neointimal hyperplasia in a canine model of coronary restenosis

    International Nuclear Information System (INIS)

    Xu Shanghua; Jiang Hong; Li Gengshan; Jiang Xuejun; Li Xiaoyan; Chen Yuanxiu; Wang Hairong; Wu Kegui; Nie Xiaomin

    2004-01-01

    Objective: To assesses the efficiency of 32 P and diallyl trisulfide (DT)-coated coronary stents on neointimal proliferation in a canine model of restenosis. Methods: 32 P (740 kBq/stent), DT (210 μg/stent) alone and jointly coated stents were deployed with mild oversizing in both the left circumflex coronary artery (LCX) and the left anterior descending coronary artery (LAD) of 10 dogs. The implantation of protein-coated stents was used as the control. The therapeutic effect was assessed 6 months after the intervention. The dogs were sacrificed and the vessels were excised. For morphologic examinations the tissue sections were stained with HE and Van Gieson. Results: Compared with the control stents, the neointimal area reduced in stents coated with 32 P, DT alone and 32 P+DT [ 32 P: (2.63±0.48) mm 2 , DT: (2.50±0.49) mm 2 , 32 P+DT: (1.42±0.41) mm 2 vs control group: (4.87±0. 80) mm 2 , P=0.001]. 32 P+DT was more effective than either of them alone for reducing the neointimal area (P≤0.005). Both jointly and alone coated stents of 32 P, DT decreased the percent area stenosis [ 32 P: (32.48±4.79)%, DT: (30.04±5.43)%, 32 P+DT: (17.21±4.05)% vs control group: (54.62±6.82)%, P 32 P+DT group compared with 32 P or DT-coated stents group (P≤0.001). Angiographic restenosis (diameter stenosis) was lighter in stents coated with 32 P, DT and 32 P+DT compared with control stents (P 32 P+DT was more effective than 32 P or DT alone for reducing diameter stenosis (P≤0.005). No evidence of 'edge effect' was seen in adjacent, nonstented coronary segments. Conclusion: Coronary stents coated with 32 P plus DT produced a significantly reduced neointimal hyperplasia and restenosis rate in the canine LCX and LAD 6 months after stents implantation

  13. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    Science.gov (United States)

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  14. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. H.; Kim, S. K.; Cha, K. S.; Kim, Y. D.; Lee, H. S.; Kang, D. Y. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result.

  15. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    Science.gov (United States)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; Pstent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels 15 mm length. © 2016 John Wiley & Sons Ltd.

  16. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    Science.gov (United States)

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, pB2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, pSPIRIT II trial population.

  17. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p 1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  18. Laser Atherectomy for Treatment of Femoropopliteal In-Stent Restenosis.

    Science.gov (United States)

    Armstrong, Ehrin J; Thiruvoipati, Thejasvi; Tanganyika, Kundai; Singh, Gagan D; Laird, John R

    2015-08-01

    To investigate if laser atherectomy with adjunctive balloon angioplasty can improve endovascular treatment outcomes for femoropopliteal in-stent restenosis (ISR). A dual center study included 135 symptomatic patients (mean age 71 years; 76 men) who underwent endovascular treatment of femoropopliteal ISR between 2006 and 2013. Of these, 54 (40%) were treated with laser atherectomy and the remaining 81 patients with balloon angioplasty alone. Angiographic images were reviewed for lesion morphology and characteristics, TransAtlantic InterSociety Consensus (TASC) II classification, and distal runoff. Class I ISR was defined as focal lesions ≤50 mm, class II ISR as lesions >50 mm, and class III ISR as stent total occlusion. Recurrent ISR was determined by a peak systolic velocity ratio >2.4 by duplex ultrasound. Patients treated with laser atherectomy had longer mean ISR lesion length (222 vs 114 mm, patherectomy and rates of recurrent restenosis or occlusion for patients with class I/II ISR, but there was a significantly lower rate of target lesion revascularization at 2 years among patients treated with laser atherectomy (14% vs 44%, p=0.05). In comparison, patients with class III ISR treated with laser atherectomy had lower rates of recurrent restenosis at 1 year (54% vs 91%, p=0.05) and 2 years (69% vs 100%, p=0.05). Patients with class III ISR treated with laser atherectomy also had lower rates of recurrent in-stent occlusion at 2-year follow-up (33% vs 71%, p=0.04). When used to treat complex ISR, including in-stent occlusions, laser atherectomy with adjunctive balloon angioplasty may be associated with improved patency. © The Author(s) 2015.

  19. The effect of stent structure changes on the hemodynamics and the formation of in-stent restenosis

    International Nuclear Information System (INIS)

    Wu Xia; Xu Ke; Xiao Liang; Zhang Xitong; Su Hongying; Feng Bo

    2009-01-01

    Objective: To investigate the effect of stent structure changes on the formation of in-stent restenosis by studying the influence of these changes on the shear force to the vascular wall, on the velocity of flow and on the flow pattern. Methods: Five stent models were established by using Pro/engineer wildfire 3.0. Model A was regarded as control structure. On the base structure of model A, transverse link component was added to form model B, and vertical link component was added to form model C. The thickness of model D was twice than that of model A, and the meshes density of model E was twice than that of model A. Fluid models were built up by importing these stent models into computational fluid dynamics (CFD) software ansys11.0-CFX, then, CFD analysis was proceeded to study the effect of stent structure on hemodynamics. Results: After the stents were implanted, the percentage of low wall shear stress on the surface of model A, B, C, D and E was 7.78%, 6.65%, 1.48%, 16.52% and 12.12%, respectively. The percentage of D and E was obviously larger than that of A, while the percentage of B was markedly smaller than that of A. The velocity vector on the cross-sectional planes showed that the low velocity and eddy areas in D and E were much larger than that in A, while this area in C was smaller than that in A. Conclusion: The stent structure changes can cause obvious changes in hemodynamics in the implanted vessels. The increase in the thickness and meshes density of the stent is the main factor that induces the formation of low wall shear stress, which will precipitate the development of in-stent restenosis. The added vertical link component will reduce the area of low wall shear stress as well as the occurrence of in-stent restenosis. (authors)

  20. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis).

    Science.gov (United States)

    Dippel, Eric J; Makam, Prakash; Kovach, Richard; George, Jon C; Patlola, Raghotham; Metzger, D Christopher; Mena-Hurtado, Carlos; Beasley, Robert; Soukas, Peter; Colon-Hernandez, Pedro J; Stark, Matthew A; Walker, Craig

    2015-01-01

    The purpose of this study was to evaluate the safety and efficacy of excimer laser atherectomy (ELA) with adjunctive percutaneous transluminal angioplasty (PTA) versus PTA alone for treating patients with chronic peripheral artery disease with femoropopliteal bare nitinol in-stent restenosis (ISR). Femoropopliteal stenting has shown superiority to PTA for lifestyle-limiting claudication and critical limb ischemia, although treating post-stenting artery reobstruction, or ISR, remains challenging. The multicenter, prospective, randomized, controlled EXCITE ISR (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis) trial was conducted across 40 U.S. centers. Patients with Rutherford Class 1 to 4 and lesions of target lesion length ≥4 cm, vessel diameter 5 to 7 mm were enrolled and randomly divided into ELA + PTA and PTA groups by a 2:1 ratio. The primary efficacy endpoint was target lesion revascularization (TLR) at 6-month follow up. The primary safety endpoint was major adverse event (death, amputation, or TLR) at 30 days post-procedure. Study enrollment was stopped at 250 patients due to early efficacy demonstrated at a prospectively-specified interim analysis. A total of 169 ELA + PTA subjects (62.7% male; mean age 68.5 ± 9.8 years) and 81 PTA patients (61.7% male; mean age 67.8 ± 10.3 years) were enrolled. Mean lesion length was 19.6 ± 12.0 cm versus 19.3 ± 11.9 cm, and 30.5% versus 36.8% of patients exhibited total occlusion. ELA + PTA subjects demonstrated superior procedural success (93.5% vs. 82.7%; p = 0.01) with significantly fewer procedural complications. ELA + PTA and PTA subject 6-month freedom from TLR was 73.5% versus 51.8% (p < 0.005), and 30-day major adverse event rates were 5.8% versus 20.5% (p < 0.001), respectively. ELA + PTA was associated with a 52% reduction in TLR (hazard ratio: 0.48; 95% confidence interval: 0.31 to 0.74). The EXCITE ISR trial is the first large, prospective, randomized study

  1. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    NARCIS (Netherlands)

    Onuta, Geanina; Groenewegen, Hendrik C.; Klatter, Flip A.; Boer, Mark Walther; Goris, Maaike; van Goor, Harry; Roks, Anton J. M.; Rozing, Jan; de Smet, Bart J. G. L.; Hillebrands, Jan-Luuk

    2011-01-01

    Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on development of

  2. Long-term type 1 diabetes enhances in-stent restenosis after aortic stenting in diabetes-prone BB rats

    NARCIS (Netherlands)

    J.-L. Hillebrands (Jan-Luuk); G. Onuta (Geanina); H.C. Groenewegen (Hendrik); F.A. Klatter (Flip); M. Walther Boer (Mark); M. Goris (Maaike); H. van Goor (Harry); A.J.M. Roks (Anton); J. Rozing (Jan); B.J.G.L. de Smet (Bart)

    2011-01-01

    textabstractType 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on

  3. Novel Use of an Orbital Atherectomy Device for In-Stent Restenosis: Lessons Learned

    Directory of Open Access Journals (Sweden)

    K. Shaikh

    2016-01-01

    Full Text Available We present a case of a 67-year-old man with stage III chronic kidney disease, uncontrolled diabetes mellitus, coronary artery disease, and high surgical risk who presented with two episodes of acute coronary syndrome attributed to in-stent restenosis (ISR associated with heavily calcified lesions. In this case, we were able to improve luminal patency with orbital atherectomy system (OAS; however, withdrawal of the device resulted in a device/stent interaction, causing failure of the device. Given limitations in current evidence and therapies, managing ISR can be a technical and cognitive challenge. Balloon expansion of the affected region often provides unsatisfactory results, possibly related to significant calcium burden. OAS could be an efficacious way of reestablishing luminal patency in ISR lesions, as these lesions are often heavily calcified.

  4. Drug-eluting stent implantation for the percutaneous treatment of vertebro-basilar arterial stenosis

    International Nuclear Information System (INIS)

    Ma Rujun; Liu Jianmin; Huang Haiqing; Hong Bo; Xu Yi; Zhao Wenyuan; Zhao Rui; Chen Jun

    2006-01-01

    Objective: To evaluate the early results and mid-term outcomes following angioplasty of vertebro-basilar arterial stenosis with drug-eluting stents. Methods: All of the patients presented with recurrent TIA or ceretral infarction with >50% stenoses in vertebro-basilar arteries, and having failure in maximal medical therapy. All of the lesions were treated with primary stenting under local or general anesthesia and followed by continual anticoagulant therapy of clopidogrel and aspirin together with clinical follow-up and vascular imagings. Results: Of 28 stenoses (27 patients), 27 lesions were successfully treated with implantation of 24 Cypher stents, 2 Taxus stents and one Firebird stent. The mean stenotic severity reduced from (74 ± 6.7)% to (8.7 ± 4.4)%. Two patients had inchemic events relating to penetration vascular obstruction. During 2-14 months follow-up, the patients were clinically asymptomatic with no recurrent TIA/stoke. Angiographic follow-up was obtained in 14 patients at a mean of 7.2 months. Proximal restenosis (<50%) occurred in one patient (3.3%), and corrected with restenting, while others were free of intra-stent restenoses. Conclusion: Using DES in cerebrovascular stenosis is safe and effective with lowing the risk of intra-stent restenosis in comparison with bare stent. Further study for long term efficiency is still in need. (authors)

  5. The Erasme Study: A Multicenter Study on the Safety and Technical Results of the Palmaz Stent Used for the Treatment of Atherosclerotic Ostial Renal Artery Stenosis

    International Nuclear Information System (INIS)

    Bakker, Jeannette; Goffette, Pierre P.; Henry, Michel; Mali, Willem P.T.M.; Melki, Jean-Pierre; Moss, Jon G.; Rabbia, Claudio; Therasse, Eric; Thomson, Kenneth R.; Thurnher, Siegfried; Vignali, Claudio

    1999-01-01

    Purpose: To assess, in a multicenter setting, safety, technical results, and restenosis rate of the Palmaz stent for treatment of atherosclerotic ostial renal artery stenosis. Methods: Ten centers enrolled 106 patients (120 treated renal artery stenoses) in the study. Patient selection was based on unsuccessful percutaneous transluminal renal angioplasty (residual stenosis ≥ 20%) performed for treatment of ostial stenosis ≥ 50%, in patients with hypertension and/or impaired renal function. Safety was assessed by means of the complication rate, and technical results by the number of successful stent placements and occurrence of restenosis (>50%) at intraarterial angiographic follow-up. Results: Stent placement was successful (n = 112) or partially successful (n = 5) in 117 (98%) arteries. Complications occurred in 19 procedures; seven were of serious clinical significance. Angiographic follow-up was performed in 89 of 117 (76%) cases, at a mean of 8 months (range 2.5-18 months). Fifteen stents (16.9%) showed restenosis (at a mean of 8.5 months), of which 10 were successfully redilated. Conclusion: Renal artery stenting has a high technical success rate, a complication rate comparable to percutaneous transluminal renal angioplasty, and a low rate of restenosis at 8 months angiographic follow-up

  6. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    Science.gov (United States)

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion

  7. Hemodynamics in stented vertebral artery ostial stenosis based on computational fluid dynamics simulations.

    Science.gov (United States)

    Qiao, Aike; Dai, Xuan; Niu, Jing; Jiao, Liqun

    2016-01-01

    Hemodynamic factors may affect the potential occurrence of in-stent restenosis (ISR) after intervention procedure of vertebral artery ostial stenosis (VAOS). The purpose of the present study is to investigate the influence of stent protrusion length in implantation strategy on the local hemodynamics of the VAOS. CTA images of a 58-year-old female patient with posterior circulation transient ischemic attack were used to perform a 3D reconstruction of the vertebral artery. Five models of the vertebral artery before and after the stent implantation were established. Model 1 was without stent implantation, Model 2-5 was with stent protruding into the subclavian artery for 0, 1, 2, 3 mm, respectively. Computational fluid dynamics simulations based on finite element analysis were employed to mimic the blood flow in arteries and to assess hemodynamic conditions, particularly the blood flow velocity and wall shear stress (WSS). The WSS and the blood flow velocity at the vertebral artery ostium were reduced by 85.33 and 35.36% respectively after stents implantation. The phenomenon of helical flow disappeared. Hemodynamics comparison showed that stent struts that protruded 1 mm into the subclavian artery induced the least decrease in blood speed and WSS. The results suggest that stent implantation can improve the hemodynamics of VAOS, while stent struts that had protruded 1 mm into the subclavian artery would result in less thrombogenesis and neointimal hyperplasia and most likely decrease the risk of ISR.

  8. Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Almutairi, Abdulrahman Marzouq D.

    2010-01-01

    Purpose: The aim of this study was to perform a meta-analysis of the diagnostic accuracy of 64-slice CT angiography for the detection of coronary in-stent restenosis in patients treated with coronary stents when compared to conventional coronary angiography. Materials and methods: A search of PUBMED/MEDLINE, ProQuest and Cochrane library databases for English literature was performed. Only studies comparing 64-slice CT angiography with conventional coronary angiography for the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model. Results: Fourteen studies met selection criteria for inclusion in the analysis. The mean value of assessable stents was 89%. Prevalence of in-stent restenosis following coronary stenting was 20% among these studies. Pooled estimates of the sensitivity and specificity of overall 64-slice CT angiography for the detection of coronary in-stent restenosis was 90% (95% CI: 86%, 94%) and 91% (95% CI: 90%, 93%), respectively, based on the evaluation of assessable stents. Diagnostic value of 64-slice CT angiography was found to decrease significantly when the analysis was performed with inclusion of nonassessable segments in five studies, with pooled sensitivity and specificity being 79% (95% CI: 68%, 88%) and 81% (95% CI: 77%, 84%). Stent diameter is the main factor affecting the diagnostic value of 64-slice CT angiography. Conclusion: Our results showed that 64-slice CT angiography has high diagnostic value (both sensitivity and specificity) for detection of coronary in-stent restenosis based on assessable segments when compared to conventional coronary angiography.

  9. Factors Associated with In-stent Restenosis in Patients Following Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Dedi Wihanda

    2015-07-01

    Full Text Available Aim: to determine factors associated with In-Stent Restenosis (ISR in patients following Percutaneous Coronary Intervention (PCI. Methods: a retrospective cross-sectional study was conducted using secondary information from medical records of post-PCI patients who underwent follow-up of angiography PCI between January 2009 and March 2014 at The Integrated Cardiovascular Service Unit, Cipto Mangunkusumo Hospital, Jakarta. Angiographic ISR was defined when the diameter of stenosis ≥50% at follow-up angiography including the diameter inside the stent and diameter with five-mm protrusion out of the proximal and distal ends of the stent. Results: there were 289 subjects including 133 subjects with and 156 subjects without ISR. The incidence of ISR in patients using of bare-metal stent (BMS and drug-eluting stent (DES were 61.3% and 40.7%, respectively. Factors associated with ISR are stent-type (OR=4.83, 95% CI 2.51-9.30, stent length (OR=3.71, 95% CI 1.99-6.90, bifurcation lesions (OR=2.43, 95% CI 1.16-5.10, smoking (OR=2.30, 95% CI 1.33-3.99, vascular diameter (OR=2.18, 95% CI 1.2-3.73, hypertension (OR=2.16, 95% CI 1.16-4.04 and diabetes mellitus (OR=2.14, 95% CI 1.23-3.70. Conclusion: stent type, stent length, bifurcation lesions, smoking, vascular diameter, hypertension and DM are factors associated with ISR in patients following PCI. Key words: bare-metal stent; drug-eluting stent; in-stent restenosis.

  10. In-Stent Restenosis of Drug-Eluting Stents Compared With a Matched Group of Patients With De Novo Coronary Artery Stenosis.

    Science.gov (United States)

    Buchanan, Kyle D; Torguson, Rebecca; Rogers, Toby; Xu, Linzhi; Gai, Jiaxiang; Ben-Dor, Itsik; Suddath, William O; Satler, Lowell F; Waksman, Ron

    2018-03-13

    Drug-eluting stents (DES) significantly reduced the incidence of in-stent restenosis (ISR). However, ISR still exists in the contemporary DES era. Previously deemed to be a benign process, ISR leads to complex presentation and intervention. This study aimed to compare the presentation and outcome of DES-ISR versus de novo lesions. We performed a retrospective analysis of 11,666 patients receiving percutaneous coronary intervention from 2003 to 2017 and divided them into 2 groups by de novo stenosis and ISR. They were matched based on common cardiovascular risk factors at a 4:1 ratio, respectively. After matching, a total of 1,888 patients with 3,126 de novo lesions and 472 patients with 508 ISR lesions were analyzed. Patients with ISR presented more often with unstable angina (61% vs 45%, p stent technique and should motivate the continued development of fully bioresorbable scaffolds. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Angioplasty and stent placement in the treatment of radiation-induced arterial injury

    International Nuclear Information System (INIS)

    Liu Pengcheng; Pierre, P.; Philippe, O.; Danial, C.; Jean-Paul, B.; Cyril, B.; Jean-Pierre, C.; Denis, K.; Helve, R.; Francis, J.

    1999-01-01

    Objective: Evaluation of therapeutic efficacy and longterm patency of angioplasty and stent for the treatment of radiation induced arterial disease. Methods: PTA was attempted in 18 arterial lesions following irradiation in 14 patients. Thirteen stents were placed in 8 patients to treat occlusion (n = 3), aneurysm (n = 1), residual stenosis (n =2), multiple stenoses (n = 1), and delayed restenosis after previous balloon angioplasty (n = 1). The stents were readily visualized and patency of the stent and the target artery determined with Doppler US and (or) CT in all patients. Results: Interventional procedure was successful in 14 patients of which 8 underwent stent placement for their arterial lesions. Eleven of these patients demonstrated primary patency with relief of clinical symptoms with a mean follow-up of 2 years (range, 8 months -60 months). Clinical improvement was noted for the other patients. Eleven patients underwent PTA once or twice. One patient had PTA four times and three stents were installed, two of which were in the area of the aortic bifurcation, and one in the celiac trunk. another patient also had PTA four times and two stents were placed in the superior mesenteric artery. A stent was implanted in one patient because of PTA induced dissection and occlusion, and the arterial lesion was considered to be cured clinically after a follow-up of 5 years. Conclusions: The results suggested that PTA with single or multiple techniques may be effective immediately in the treatment of arterial lesions caused by radiation and can be considered the first therapeutic option in these cases

  12. Rotational and aspiration atherectomy for infrainguinal in-stent restenosis.

    Science.gov (United States)

    Beschorner, Ulrich; Krankenberg, Hans; Scheinert, Dierk; Sievert, Horst; Tübler, Thilo; Sixt, Sebastian; Noory, Elias; Rastan, Aljoscha; Macharzina, Roland; Zeller, Thomas

    2013-03-01

    To report feasibility and safety of the Pathway PV™ Atherectomy System during percutaneous peripheral vascular interventions of in-stent restenosis. 33 patients (66.7 % men; mean age 68.7 years; 39.4 % diabetics) with symptomatic infrainguinal in-stent restenosis were enrolled at 5 study sites. Primary study endpoint was the 30-day serious adverse event (SAE) rate. At one study site a subgroup of 13 patients was scheduled for additional follow-up examinations with duplex. Forty lesions with a mean lesion length of 85.7 mm (range 6 - 370 mm) were treated including total occlusions (20 %) and infrapopliteal lesions (5 %). In sixteen target lesions (40 %) procedural success was reached with atherectomy alone, 23 lesions (57.5 %) received adjunctive percutaneous transluminal angioplasty to obtain a sufficient angiographic result. Freedom from device-related SAEs was 100 %. Overall there were 11 unexpected adverse events in 11 patients, two of which were serious (retroperitoneal bleeding and access site infection). The ankle-brachial index increased significantly from 0.65 ± 0.13 at baseline to 0.82 ± 0.15 at 30 days. Mean Rutherford category improved from 2.8 ± 0.7 at baseline to 1.0 ± 1.2. In the subgroup with longer follow- up primary patency was 33 % after 12 months and 25 % after 24 months. Secondary patency was 92 % after 12 and 24 months. The use of the Pathway PV™ System during percutaneous peripheral vascular interventions of in-stent restenosis appears to be feasible and safe but does not seem to offer a sustainable solution regarding long term patency. A combination with drug eluting balloon angioplasty could be an interesting option and should be evaluated in further clinical trials.

  13. Matrix metalloproteinase 9 level as an indicator for restenosis following cervical and intracranial angioplasty and stenting

    Directory of Open Access Journals (Sweden)

    Jun-peng Liu

    2015-01-01

    Full Text Available Cervical and intracranial angioplasty and stenting is an effective and safe method of reducing the risk of ischemic stroke, but it may be affected by in-stent restenosis. The present study investigated serum level of matrix metalloproteinase 9 as a predictor of restenosis after 40 patients underwent cervical and/or intracranial angioplasty and stenting. Results showed that restenosis occurred in 30% (3/10 of patients when the serum level of matrix metalloproteinase 9 at 3 days after surgery was 2.5 times higher than preoperative level. No restenosis occurred when the serum level of matrix metalloproteinase 9 at 3 days after surgery was not 2.5 times higher than preoperative level. Restenosis occurred in 12% (2/17 of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for more than 30 days after surgery, but only occurred in 4% (1/23 of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for less than 30 days after surgery. However, the differences observed were not statistically significant (P > 0.05. Experimental findings indicate that when the serum level of matrix metalloproteinase 9 is 2.5 times higher than preoperative level at 3 days after cervical and intracranial angioplasty and stenting, it may serve as a predictor of in-stent restenosis.

  14. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  15. Complications in percutaneous transluminal stenting for carotid artery stenosis

    International Nuclear Information System (INIS)

    Li Shenmao; Miao Zhongrong; Zhu Fengshui; Ji Xunming; Jiao Liqun; Qi Jianshu; Ling Feng

    2007-01-01

    Objective: To discuss the complications of endovascular stenting for carotid artery stenosis. Methods: Cerebral vascular angiography and cervical Doppler sonography were performed in 648 patients with carotid artery stenosis. Emboli-protected device was used in 365 patients and none in 283 patients. Results: All 648 patients were technically successful (100%). Symptoms disappeared or improved in 78.7% patients. Slow heart rate during operation existed in 26.4% patients. Embolism caused by dislodgment of emboli occurred in 5 patients, 3 of them recovered after treatment and 2 had unilateral dyskinesias. Intracranial hemorrhage occurred in 3 patients. Stroke or death within 30 days after operation occurred in 6 patients(1.24%). 322 patients (77.8%)were followed up. Restenosis occurred in 17 patients(3.3%). Conclusion: Percutaneous transluminal stenting is a safe option for carotid artery stenosis. Correct evaluation of clinical and angiographic data before operation, together with normative manipulation and nursing during and after operation are the key points to avoid complications. (authors)

  16. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-01-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-termmorbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD. PMID:29470746

  17. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance.

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-05-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.

  18. Drug-eluting stents studies in mice: Do we need atherosclerosis to study restenosis?

    NARCIS (Netherlands)

    Pires, N.M.M.; Jukema, J.W.; Daemen, M.J.A.P.; Quax, P.H.A.

    2006-01-01

    In 2001, the first human study with drug-eluting stents (DES) was published showing a nearly complete abolition of restenosis by using a sirolimus-eluting stent. This success was very encouraging to test new compounds in combination with the DES platform. Nevertheless, several other anti-restenotic

  19. Intravascular ultrasound assessment of minimumlumen area and intimal hyperplasia in in-stent restenosis after drug-eluting or bare-metal stent implantation. The Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Vikman, Saila; Antonsen, Lisbeth

    2017-01-01

    presenting with a DES or bare-metal stent (BMS) in-stent restenosis. Methods: The ``Nordic Intravascular Ultrasound Study (NIVUS)'' study was conducted in Nordic and Baltic countries as a prospective multicenter registry. Two hundred nine patients (DES n = 121 and BMS n = 88) with instent restenosis were...

  20. Late In-Stent Restenosis of the Abdominal Aorta in a Patient with Takayasu's Arteritis and Related Pathology

    International Nuclear Information System (INIS)

    Ishibashi-Ueda, Hatsue; Yutani, Chikao; Kuribayashi, Sachio; Takamiya, Makoto; Imakita, Masami; Ando, Motomi

    1999-01-01

    This report describes an in-stent restenosis of the infrarenal aorta in a patient with Takayasu's arteritis in a nonactive state. A 10-mm-diameter Wallstent had been deployed 42 months previously. The stented restenosed segment was replaced by a surgical graft. Histopathological examination of the excised aortic segment showed a thin layer of fibrocellular neointima and massive organized and calcified thrombus. To our knowledge, this is the first histopathological report of a late in-stent restenosis of the abdominal aorta in Takayasu's arteritis. RID='''' ID='''' Correspondence to: H. Ishibashi-Ueda, M.D

  1. Number of Blades-up Runs Using JetStream XC Atherectomy for Optimal Tissue Debulking in Patients with Femoropopliteal Artery In-Stent Restenosis.

    Science.gov (United States)

    Shammas, Nicolas W; Shammas, Gail A; Aasen, Nicole; Jarvis, Gary

    2015-12-01

    Rotational atherectomy with the use of the JetStream XC device is indicated for treatment of infrainguinal arterial obstructive disease. The number of blades-up (BU) runs needed for optimal tissue debulking in femoropopliteal in-stent restenosis (ISR) is unknown. In the present series, 6 patients (15 lesions) were treated for femoropopliteal ISR with the JetStream XC device. Minimal luminal diameter or percent stenosis improved significantly from baseline after 2 BU runs, but no further gain was seen between 2 and 4 BU runs (P > .05). However, adjunctive balloon angioplasty reduced percent stenosis significantly following BU runs. In conclusion, the JetStream XC device achieved optimal acute angiographic results in treating femoropopliteal ISR following 2 BU runs and adjunctive balloon angioplasty. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  2. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    Science.gov (United States)

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)

    2016-04-15

    PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

  4. CYP2C19⁎2 Polymorphism in Chilean Patients with In-Stent Restenosis Development and Controls

    Directory of Open Access Journals (Sweden)

    Jenny Ruedlinger

    2017-01-01

    Full Text Available Clopidogrel is an antiplatelet drug especially used in patients undergoing percutaneous coronary interventions (PCI. Polymorphisms within CYP2C19 can result in important interindividual variations regarding therapeutic efficacy. Therefore, we aimed to evaluate the impact of the CYP2C19⁎2 variant (rs4244285 on in-stent restenosis occurrence in Chilean patients who underwent PCI and received clopidogrel. A total of 77 cases with stenosis >50% in the angioplasty site (62.75 ± 9.8 years, 80.5% males and 86 controls (65.45 ± 9.8 years, 72.1% males were studied. The polymorphism was genotyped using TaqMan® Drug Metabolism Genotyping Assays. Overall, CYP2C19⁎2 allele frequency was 8.3%. Diabetes, chronic lesions, and bare metal stents (BMS were observed more often in cases than in controls (p = 0.05, p = 0.04, and p = 0.02, resp.. Genotypic frequencies did not differ significantly between the groups (p = 0.15. Nonetheless, the mutated allele was observed in a greater proportion in patients without in-stent restenosis (p = 0.055. There was no significant association between the rs4244285 variant and the occurrence of in-stent restenosis after PCI (OR = 0.44; 95% CI: 0.19 to 1.04; p = 0.06. In summary, no association was identified between the CYP2C19⁎2 variant and the development of coronary in-stent restenosis.

  5. Prospective ECG-triggered axial CT at 140-kV tube voltage improves coronary in-stent restenosis visibility at a lower radiation dose compared with conventional retrospective ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun; Fujioka, Chikako; Kiguchi, Masao; Kohno, Shingo [Hiroshima University Hospital, Department of Clinical Radiology, Hiroshima (Japan); Yamamoto, Hideya; Kitagawa, Toshiro [Hiroshima University, Department of Molecular and Internal Medicine, Division of Clinical Medical Science, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan); Ito, Katsuhide [Hiroshima University, Department of Radiology, Division of Medical Intelligence and Informatics, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan)

    2009-10-15

    The purpose of this study was to compare coronary 64-slice CT angiography (CTA) protocols, specifically prospective electrocardiograph (ECG)-triggered and retrospective ECG-gated CT acquisition performed using a tube voltage of 140 kV and 120 kV, regarding intracoronary stent imaging. Coronary artery stents (n=12) with artificial in-stent restenosis (50% luminal reduction, 40 HU) on a cardiac phantom were examined by CT at heart rates of 50-75 beats per minute (bpm). The subjective visibility of in-stent restenosis was evaluated with a three-point scale (1 clearly visible, 2 visible, and 3 not visible), and artificial lumen narrowing [(inner stent diameter - measured lumen diameter)/inner stent diameter], lumen attenuation increase ratio [(in-stent attenuation - coronary lumen attenuation)/coronary lumen attenuation], and signal-to-noise ratio of in-stent lumen were determined. The effective dose was estimated. The artificial lumen narrowing (mean 43%), the increase of lumen attenuation (mean 46%), and signal-to-noise ratio (mean 7.8) were not different between CT acquisitions (p=0.12-0.91). However, the visibility scores of in-stent restenosis were different (p<0.05) between ECG-gated CTA techniques: (a) 140-kV prospective (effective dose 4.6 mSv), 1.6; (b) 120-kV prospective (3.3 mSv), 1.8; (c) 140-kV retrospective (16.4-18.8 mSv), 1.9; and (d) 120-kV retrospective (11.0-13.4 mSv), 1.9. Thus, 140-kV prospective ECG-triggered CTA improves coronary in-stent restenosis visibility at a lower radiation dose compared with retrospective ECG-gated CTA. (orig.)

  6. Stent angioplasty for the treatment of symptomatic stenosis of middle cerebral artery

    International Nuclear Information System (INIS)

    Lu Huisheng; Niu Huiming; Chao Yuanxiang; Li Xiaoning; Wu Dingfeng; Zhang Chenhong; Yang Jie; Zhang Liang

    2010-01-01

    Objective: To investigate the safety and feasibility of endovascular stent angioplasty in treating symptomatic stenosis of middle cerebral artery. Methods: Endovascular angioplasty with coronary stents was performed in 27 patients with symptomatic stenosis of middle cerebral artery. The clinical results were reviewed and analyzed. Results: Of the total 27 patients, successful placement of the coronary stents was achieved in 24. Angiography immediately after the procedure showed that the stenotic degree of the diseased artery was markedly decreased from preoperative (80 ± 19)% to postoperative (8 ±4)%, the improvement was very obvious. Percutaneous transcatheter angioplasty had to be employed in two cases because of the failure of stent placement. A mean follow-up period of 18 months was carried out. During the following up period no transient cerebral ischemia attack occurred in 25 patients and no newly-developed cerebral infarction in region fed by the responsible vessels occurred either.Re-irrigation cerebral hemorrhage was seen in one patient, which occurred three hours after the placement of the stent. In one case the placed stent fell off and immigrated into the siphon of internal carotid artery, and the displaced stent was took out later with a catching apparatus. In another case re-stenosis occurred six months after the stenting. Conclusion: Percutaneous endovascular stent angioplasty is a safe and effective treatment for symptomatic stenosis of middle cerebral artery, although its long-term results need to be further evaluated. (authors)

  7. Potential mechanisms of in-stent occlusion in the femoropopliteal artery: an angioscopic assessment.

    Science.gov (United States)

    Ishihara, Takayuki; Iida, Osamu; Okamoto, Shin; Fujita, Masashi; Masuda, Masaharu; Nanto, Kiyonori; Shiraki, Tatsuya; Kanda, Takashi; Tsujimura, Takuya; Okuno, Shota; Yanaka, Koji; Uematsu, Masaaki

    2017-10-01

    Although stent implantation has become widespread for the treatment of patients with peripheral artery disease with femoropopliteal (FP) lesions, in-stent restenosis, especially in-stent occlusion (ISO), remains as a major concern for refractory recurrence. Furthermore, the mechanisms of ISO in FP lesions have not been well elucidated. We performed angioscopy for 6 lesions (bare-metal stent: 3, drug-eluting stent: 3) from 5 patients (mean age 74 ± 10 years, male 40 %) with ISO in the FP artery immediately after wire-passing or thrombus aspiration. The presence of thrombus as well as the presence and location of organic stenosis were evaluated. Median duration from stent implantation to angioscopic evaluation was 1099.5 (514.5-2272.5) days, while the duration from recurrence of symptoms to angioscopic evaluation was 45 (5.75-60) days. Mixed thrombi were observed in all stents. Organic stenosis was detected at the proximal edge of the stents in 5 lesions. Organic stenosis was observed at the overlapping segment of the stent in one lesion. The distal edge of the stents could be evaluated in 3 lesions, and all of them showed organic stenosis at the site. Mixed thrombi and organic stenosis were observed in all stents. Partial development of organic stenosis in a stent followed by thrombus formation may be the potential mechanism of the development of ISO in the FP artery though the sample size of this study was small and it had no serial angioscopic data so that we should consider it as preliminary one at best.

  8. Assessment of coronary artery stent patency by electron-beam CT

    International Nuclear Information System (INIS)

    Knollmann, Friedrich D.; Felix, Roland; Moeller, Joerg; Gebert, Axel; Bethge, Christian

    2004-01-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  9. Assessment of coronary artery stent patency by electron-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Knollmann, Friedrich D.; Felix, Roland [Department of Radiology, Charite, Campus Virchow-Klinikum, Humboldt-University, Augustenburger Platz 1, 13353, Berlin (Germany); Moeller, Joerg; Gebert, Axel; Bethge, Christian [Department of Cardiology, Juedisches Krankenhaus, Berlin (Germany)

    2004-08-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  10. Factors inducing in-stent restenosis: an in-vitro model.

    Science.gov (United States)

    Santin, M; Morris, C; Harrison, M; Mikhalovska, L; Lloyd, A W; Mikhalovsky, S

    2004-05-01

    In-stent restenosis is caused by the proliferation of the smooth muscle cells (SMCs) following a host response towards the implanted device. However, the precise biochemical and cellular mechanisms are still not completely understood. In this paper, the behaviour of SMCs has been investigated by an in vitro model where the cells were stimulated by platelet derived growth factor (PDGF) on tissue-like substrates as well as on biomaterials such as stainless steel (St) and diamond-like carbon (DLC)-coated St. The results demonstrated that SMCs have a completely different adhesion mode on St and become particularly prone to proliferation and pro-inflammatory cytokine secretion under PDGF stimulus. This would suggest that restenosis may caused by the accidental contact of the SMC with the St substrate under an inflammatory insult.

  11. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation

    DEFF Research Database (Denmark)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian

    2017-01-01

    -stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. METHODS/RESULTS: The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability...... of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. CONCLUSION: In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt...... compared to segments treated with a DES (5.4% vs 0.76%; P15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold...

  12. A Novel Stent Coated with Antibodies to Endoglin Inhibits Neointimal Formation of Porcine Coronary Arteries

    Directory of Open Access Journals (Sweden)

    Song Cui

    2014-01-01

    Full Text Available Endoglin/CD105 is an accessory protein of the transforming growth factor-β receptor system that plays a critical role in proliferation of endothelial cells and neovasculature. Here, we aimed to assess the effect of novel stents coated with antibodies to endoglin (ENDs on coronary neointima formation. Thirty ENDs, thirty sirolimus-eluting stents (SESs, and thirty bare metal stents (BMSs were randomly assigned and placed in the coronary arteries in 30 juvenile pigs. Histomorphometric analysis and scanning electron microscopy were performed after stent implantation. Our results showed that after 7 days, there was no difference in the neointimal area and percent area stenosis in ENDs compared with SMSs or BMSs. After 14 days, the neointima area and percent area stenosis in ENDs were markedly decreased than those in BMSs or SESs (P<0.05. Moreover, the percentage of reendothelialization was significantly higher in ENDs than that in SESs or BMSs (P<0.01 at 7 and 14 days. The artery injury and the inflammation scores were similar in all groups at 7 and 14 days. In conclusion, our results demonstrated for the first time to our knowledge that endoglin antibody-coated stents can markedly reduce restenosis by enhancing reendothelialization in the porcine model and potentially offer a new approach to prevent restenosis.

  13. Randomized comparison between intracoronary β-radiation brachytherapy and implantation of paclitaxel-eluting stents for the treatment of diffuse in-stent restenosis

    International Nuclear Information System (INIS)

    Schukro, Christoph; Syeda, Bonni; Kirisits, Christian; Schmid, Rainer; Pichler, Philipp; Pokrajac, Boris; Lang, Irene; Poetter, Richard; Glogar, Dietmar

    2007-01-01

    Background and purpose: Intracoronary brachytherapy was the primary therapeutic option for the treatment of in-stent restenosis (ISR) during the last years. Especially for the treatment of diffuse ISR (lesions >10 mm), β-source brachytherapy was significantly superior to singular balloon angioplasty. Despite lacking clinical database, the implantation of drug eluting stents recently became a common procedure for the treatment of ISR. This randomized trial aimed to compare the efficacy of β-brachytherapy with β-radioisotopes 90 Sr/ 90 Y and paclitaxel-eluting stent implantation for the treatment of diffuse ISR. Material and methods: Thirty-seven patients with diffuse ISR were randomly assigned to β-brachytherapy after balloon angioplasty (Beta-Cath TM in 17 patients) or paclitaxel-eluting stent implantation (Taxus-Express2 TM in 20 patients). Six-month clinical follow-up was obtained for all patients, while angiographic follow-up was available for 30 patients. Results: Binary ISR (restenosis >50%) within target segment was observed in three patients treated with Beta-Cath TM , of which one needed target segment revascularisation for recurrent ISR, whereas no significant restenosis occurred in the patients treated with Taxus-Express2 TM (P = 0.037). No further major adverse cardiac (target segment revascularisation, myocardial infarction, death) was found in either group (P = NS). Stent implantation was the more time-saving (31 ± 11 min versus 60 ± 23 min, P TM arm, we found no difference in clinical outcome after implantation of paclitaxel-eluting stents for the treatment of diffuse ISR when compared to β-brachytherapy

  14. Experimental study of 103Pd stents for preventing the restenosis of biliary duct

    International Nuclear Information System (INIS)

    Gao Qinyi; Shu Qiang; Lu Xiangdong; Li Yaming; He Guijin; Pei Zhuguo; Xu Shuhe

    2004-01-01

    Objective: To explore the feasibility of preventing biliary duct restenosis with the stent treated with 103 Pd and to elucidate the mechanisms of the inhibition of the smooth muscle cell proliferation and the increase of apoptosis. Methods: The experimental dogs were randomly divided into common-stent group and 103 Pd stent group, each of 6 animals. Pathohistology, cell apoptosis, immunohistochemistry for proliferating cell nuclear antigen (PCNA), the expression of gene p53 by in situs hybridization, the test of the peripheral blood and measurement of radiation of tissue around the stent were studied. Results: The utmost intimal thickness of biliary duct in the 103 Pd stent group was found to be obviously less compared to that in common-stent group after 30 d, the percentages of the stenosis of the biliary duct were (54.73 ± 21.64)% and (17.61 ± 14.52)%, respectively, there was a significant difference between two groups (P 103 Pd stent group, and decreased in the common-stent group; the expression of PCNA of biliary smooth muscle cells of 103 Pd group was weaker compared with that in the common-group. Conclusion: 103 Pd stent may inhibit the proliferation of smooth muscle cells and prevent the restenosis of biliary duct. (authors)

  15. In vitro and in vivo cell-capture strategies using cardiac stent technology - A review.

    Science.gov (United States)

    Ravindranath, Rohan R; Romaschin, Alexander; Thompson, Michael

    2016-01-01

    Stenosis is a symptom of coronary artery disease (CAD), and is caused by narrowing of arteries in the heart. Over the last several decades, medical implants such as cardiac stents have been developed to counter stenosis. Upon implantation of a stent to open up a restricted artery, narrowing of the artery can reoccur (restenosis), due to an immune response launched by the body towards the stent. Currently, restenosis is a major health concern for patients who have undergone heart surgery for coronary artery disease. Recently, there have been new methods developed to combat restenosis, which have shown potential signs of success. One proposed method is the use of stents to capture cells, thereby reducing immune response. This review will explore the different methods for cell capture both in vitro and in vivo. Biological modifications of the stent will be surveyed, as well as the use of surface science to immobilize biological probes. Immobilization of proteins and nucleotides, as well as use of magnetic field are all methods that will be further discussed. Finally, concluding remarks and future prospects will be presented. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    Science.gov (United States)

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  17. Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris

    2017-08-01

    Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

  18. A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); De Cecco, Carlo N.; Yamada, Ricardo T.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Fuller, Stephen R. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Vogl, Thomas J.; Wichmann, Julian L. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Todoran, Thomas M. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States)

    2016-12-15

    To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F{sub 0}.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F{sub 0}.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F{sub 0}.5 (16.9 ± 4.8; all p < 0.0463); luminal stent diameters were increased at ≥70 keV (5.41 ± 1.8-5.92 ± 1.7 vs. 5.27 ± 1.8, all p < 0.001) and diagnostic confidence was highest at 70-80 keV-VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F{sub 0}.5 (90.9, 94.1, 89.3 %). 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. (orig.)

  19. Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy

    Energy Technology Data Exchange (ETDEWEB)

    Martí, David, E-mail: docalcala@hotmail.com [Department of Cardiology, Hospital Central de la Defensa, Madrid (Spain); López, Edurne; Álvarez, Salvador; Palazuelos, Jorge; Rada, Ignacio [Department of Cardiology, Hospital Central de la Defensa, Madrid (Spain); Alfonso, Fernando [Department of Cardiology, Hospital Universitario de La Princesa, Madrid (Spain)

    2016-12-15

    The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. - Highlights: • Optical coherence tomography (OCT) has the unique ability to detect lipid accumulation within the stent margins (i.e. neoatherosclerosis). • Lipid-rich tissues produce light absorption and therefore they typically attenuate backward signals. • Occlusive neoatherosclerosis may appear even in optimally implanted drug eluting stents. • OCT identification of restenosis mechanisms may have implications not only in the interventional strategy, but also in the long-term medical treatment.

  20. Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy

    International Nuclear Information System (INIS)

    Martí, David; López, Edurne; Álvarez, Salvador; Palazuelos, Jorge; Rada, Ignacio; Alfonso, Fernando

    2016-01-01

    The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. - Highlights: • Optical coherence tomography (OCT) has the unique ability to detect lipid accumulation within the stent margins (i.e. neoatherosclerosis). • Lipid-rich tissues produce light absorption and therefore they typically attenuate backward signals. • Occlusive neoatherosclerosis may appear even in optimally implanted drug eluting stents. • OCT identification of restenosis mechanisms may have implications not only in the interventional strategy, but also in the long-term medical treatment.

  1. Anti-Inflammatory Effect of Gallic Acid-Eluting Stent in a Porcine Coronary Restenosis Model

    Science.gov (United States)

    Seob Lim, Kyung; Park, Jun-Kyu; Ho Jeong, Myung; Ho Bae, In; Sung Park, Dae; Won Shim, Jae; Ha Kim, Jung; Kuk Kim, Hyun; Soo Kim, Sung; Sun Sim, Doo; Joon Hong, Young; Han Kim, Ju; Ahn, Youngkeun

    2018-01-01

    Background Gallic acid (3,4,5-trihydroxybenzoic acid) is a natural polyphenol and strong natural antioxidant found abundantly in red wine and green tea. The aim of this study was to examine the anti-inflammatory effect of a novel gallic acid-eluting stent in a porcine coronary restenosis model. Methods Fifteen pigs were randomized into three groups; in which a total of 30 coronary arteries (10 in each group) were implanted with gallic acid-eluting stents (GESs, n = 10), gallic acid and sirolimus-eluting stents (GSESs, n = 10), or sirolimus-eluting stents (SESs, n = 10). Histopathologic analysis was performed 28 days after stenting. Results There were no significant differences in injury score and fibrin score among the groups, however there were significant differences in the internal elastic lamina (4.0 ± 0.83 mm2 in GES vs. 3.0 ± 0.53 mm2 in GSES vs. 4.6 ± 1.43 mm2 in SES, p < 0.0001), lumen area (2.3 ± 0.49 mm2 in GES vs. 1.9 ± 0.67 mm2 in GSES vs. 2.9 ± 0.56 mm2 in SES, p < 0.0001), neointimal area (1.7 ± 0.63 mm2 in GES vs. 1.1 ± 0.28 mm2 in GSES vs. 1.7 ± 1.17 mm2 in SES, p < 0.05), and percent area of stenosis (42.4% ± 9.22% in GES vs. 38.2% ± 12.77% in GSES vs. 33.9% ± 15.64% in SES, p < 0.05). The inflammation score was significantly lower in the GES and GSES groups compared to that in the SES group [1.0 (range: 1.0 to 2.0) in GES vs. 1.0 (range: 1.0 to 1.0) in GSES vs. 1.5 (range: 1.0 to 3.0) in SES, p < 0.05]. Conclusions The GES group had a greater percent area of stenosis than the SES group. Although gallic acid in the GES and GSES groups did not show a synergistic effect in suppressing neointimal hyperplasia, it resulted in greater inhibition of the inflammatory reaction in the porcine coronary restenosis model than in the SES group. PMID:29844643

  2. Superficial femoral artery TASC D Registry: twelve-month effectiveness analysis of the Pulsar-18 SE nitinol stent in patients with critical limb ischemia.

    Science.gov (United States)

    Lichtenberg, M; Stahlhoff, W; Boese, D

    2013-08-01

    Single center observational study analyzing the primary patency rate and freedom from target lesions revascularization rate of the Pulsar-18 nitinol stent after recanalization of long superficial femoral artery (SFA) occlusions (TASC D) in 22 patients with critical limb ischemia (CLI). Between 1/2011 and 7/2011, 22 consecutive patients (9 male, 13 female) with chronic total occlusions (CTO) of the femoro-popliteal arteries presenting with CLI (17 patients with Rutherford 4 score, and 5 patients with Rutherford 5 score) were enrolled and successfully recanalized using the Pulsar-18 self-expanding (SE) nitinol stent (BIOTRONIK AG, Buelach, Switzerland). Primary patency at 12 months was defined as no binary restenosis (>50%) on Duplex ultrasound (PSVRPulsar-18 SE nitinol stent was 77% with a per protocol restenosis in 5 of 22 patients. Seventeen patients showed a walking capacity on treadmill test >300 meters (Rutherford II). Two patients with a documented restenosis were Rutherford, these patients were treated conservatively. Three patients with restenosis and a Rutherford III score were scheduled for an endovascular target lesion revascularization leading to a freedom from target lesion revascularization rate of 86%. Endovascular intervention of long SFA occlusions using subintimal or intraluminal recanalization technique with implantation of the Pulsar-18 SE nitinol stent in CLI patients is safe and clinically effective with a primary patency rate after 12 months of 77% and a freedom from target lesion revascularization rate of 86%.

  3. Extracranial Carotid Artery Stenting in Surgically High-Risk Patients Using the Carotid Wallstent Endoprosthesis:Midterm Clinical and Ultrasound Follow-Up Results

    International Nuclear Information System (INIS)

    Maleux, Geert; Bernaerts, Pauwel; Thijs, Vincent; Daenens, Kim; Vaninbroukx, Johan; Fourneau, Inge; Nevelsteen, Andre

    2003-01-01

    The purpose of this study was to evaluate the feasibility, safety and midterm outcome of elective implantation of the Carotid Wallstent (registered) in patients considered to be at high surgical risk. In a prospective study, 54 carotid artery stenoses in 51 patients were stented over a 24-month period. Three patients underwent bilateral carotid artery stenting. Institutional inclusion criteria for invasive treatment of carotid occlusive disease (carotid endarterectomy or carotid artery stenting) are patients presenting with a 70% or more symptomatic stenosis and those with an 80% or more asymptomatic stenosis having a life-expectancy of more than 1 year. All patients treated by carotid artery stenting were considered at high risk for carotid endarterectomy because of a hostile neck (17 patients-31.5%) or because of severe comorbidities (37 patients-68.5%). No cerebral protection device was used. Of the 54 lesions, 33 (61.1%) were symptomatic and 21 (38.8%) were asymptomatic. Follow-up was performed by physical examination and by duplex ultrasonography at 1 month, 6 months, 1 year and 2 years after the procedure. All 54 lesions could be stented successfully without periprocedural stroke. Advert events during follow-up (mean 13.9 ± 5.7 months) were non-stroke-related death in 6 patients (11.1%), minor stroke in 4 stented hemispheres(7.4%), transient ipsilateral facial pain in 1 patient (1.8%),infection of the stented surgical patch in 1 patient (1.8%) and asymptomatic in stent restenosis in 4 patients (7.4%). The percutaneous implantation of the Carotid Wallstent (registered) , even without cerebral protection device, appears to be a safe procedure with acceptable clinical and ultrasonographic follow-up results in patients at high surgical risk. But some late adverse events such as ipsilateral recurrence of non-disabling (minor) stroke or in stent restenosis still remain real challenging problems

  4. Clinical benefits of drug-eluting stent implantation in septuagenarians with coronary artery disease

    International Nuclear Information System (INIS)

    Fang Yuehua; Shen Weifeng; Zhang Ruiyan; Zhang Jiansheng; Hu Jian; Zhang Xian; Zheng Aifang

    2005-01-01

    Objective: This study evaluated the safety and long-term outcomes of drug-eluting stents in septuagenarians with coronary artery disease. Methods: Two hundred and thirty-nine consecutive patients with coronary artery disease underwent drug-eluting stenting, including 88 patients aged ≥70 years (group A) and 151 aged <70 years (group B). Baseline clinical characteristics, procedural success rate, occurrence of cardiac events during follow-up were recorded and compared between the two groups. Results: Procedural success rate and complications were similar for the two groups. During follow-up, group A had higher recurrence rate of chest pain than group B (23.9% vs. 7.3%, P<0.001), and occurrence of cardiac events was higher in group A than in group B (5.7% vs. 2.7%, P<0.296). There was no significant difference in the frequency of restenosis between the two groups. Conclusions: Drug-eluting stent implantation for septuagenarians with coronary artery disease is safe but may have more recurrence of angina than younger ones during long-term follow-up. (authors)

  5. Optimization of cardiovascular stent against restenosis: factorial design-based statistical analysis of polymer coating conditions.

    Directory of Open Access Journals (Sweden)

    Gayathri Acharya

    Full Text Available The objective of this study was to optimize the physicodynamic conditions of polymeric system as a coating substrate for drug eluting stents against restenosis. As Nitric Oxide (NO has multifunctional activities, such as regulating blood flow and pressure, and influencing thrombus formation, a continuous and spatiotemporal delivery of NO loaded in the polymer based nanoparticles could be a viable option to reduce and prevent restenosis. To identify the most suitable carrier for S-Nitrosoglutathione (GSNO, a NO prodrug, stents were coated with various polymers, such as poly (lactic-co-glycolic acid (PLGA, polyethylene glycol (PEG and polycaprolactone (PCL, using solvent evaporation technique. Full factorial design was used to evaluate the effects of the formulation variables in polymer-based stent coatings on the GSNO release rate and weight loss rate. The least square regression model was used for data analysis in the optimization process. The polymer-coated stents were further assessed with Differential scanning calorimetry (DSC, Fourier transform infrared spectroscopy analysis (FTIR, Scanning electron microscopy (SEM images and platelet adhesion studies. Stents coated with PCL matrix displayed more sustained and controlled drug release profiles than those coated with PLGA and PEG. Stents coated with PCL matrix showed the least platelet adhesion rate. Subsequently, stents coated with PCL matrix were subjected to the further optimization processes for improvement of surface morphology and enhancement of the drug release duration. The results of this study demonstrated that PCL matrix containing GSNO is a promising system for stent surface coating against restenosis.

  6. Six-year clinical follow-up after treatment of diffuse in-stent restenosis with cutting balloon angioplasty followed by intracoronary brachytherapy with liquid rhenium-188-filled balloon via transradial approach

    International Nuclear Information System (INIS)

    Hang Chiling; Wu Chiungjen; Hsieh Bortsung

    2010-01-01

    Long-term follow-up studies revealed a significant decline in the benefits of intracoronary radiation for in-stent restenosis. A total of 25 study and 25 contemporaneous control patients with diffuse in-stent restenosis who underwent cutting balloon angioplasty (CBA) transradially, followed by subsequent intracoronary irradiation with a liquid β-emitter Rhenium-188 ( 188 Re)-filled balloon were enrolled in the study. The mean clinical follow-up durations were 64.9±13.0 and 66.3±13.8 months for the irradiated and control patients, respectively. Six-month angiographic restenosis was observed in 16% (4 of 25) of the patients in the irradiated group and 48% (12 of 25) of the patients in the control groups (P=0.03). The 6-month major adverse cardiac events (MACE) rate was 12% and 44%, respectively (P=0.025). The 3-year follow-up angiography was performed in 16 of 21 (76%) irradiated patients and in 4 of 13 (31%) control patients who had no significant restenosis at the 6-month angiographic follow-up. Restenosis occurred in 1 of 16 (7%) irradiated patients and 2 of 4 (50%) control patients. Late target lesion revascularization was performed in 1 irradiated and 2 control patients. The MACE rate within 6 years was significantly reduced in the irradiated group (20% vs. 56%, P=0.019). Brachytherapy using 188 Re-filled balloon following CBA for diffuse in-stent restenotic native coronary arteries is effective in reducing target lesion restenosis and improving long-term outcomes. (author)

  7. Impact of Angioscopic Evaluation for Femoropopliteal In-Stent Restenosis Before and After Excimer Laser Atherectomy.

    Science.gov (United States)

    Idemoto, Akiko; Okamoto, Naotaka; Tanaka, Akihiro; Mori, Naoki; Nakamura, Daisuke; Yano, Masamichi; Makino, Nobuhiko; Egami, Yasuyuki; Shutta, Ryu; Tanouchi, Jun; Nishino, Masami

    2017-07-01

    In-stent restenosis (ISR) is a prevalent problem following stenting of femoropopliteal lesions. A potential novel treatment modality for ISR including excimer laser atherectomy (ELA) has become available. We performed ELA for in-stent chronic total occlusion (CTO) of femoropopliteal lesions and evaluated lesion morphology before and after ELA by angioscopy in 2 patients. The angioscopic findings clearly showed removal of in-stent thrombi after ELA. Thus, ELA may be effective for in-stent CTO of femoropopliteal lesions. This is the first report describing the direct visualization of ELA effect for vaporization of thrombi in femoropopliteal in-stent lesions by angioscopy.

  8. Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    Science.gov (United States)

    Fan, Zhenmin; Liu, Xiao; Sun, Anqiang; Zhang, Nan; Fan, Zhanming; Fan, Yubo; Deng, Xiaoyan

    2017-10-01

    Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the possibility, we constructed a patient-specific carotid model with two components of plaques (lipid and calcified plaque) based on MRI images; we numerically compared three different stenting scenarios in terms of von Mises stress (VMS) distribution in the treated arteries, namely, the short stenting (LAM), the medium stenting and the long stenting. The results showed that the short stenting led to more areas with abnormally high VMS along the inner surface of the treated artery with a much higher surface-averaged VMS at the distal end of the stent than both the medium and long stenting. While the VMS distribution in the calcified plaques was similar for the three stenting models, it was quite different in the lipid plaques among the three stenting models. The lipid plaque of the short-stent model showed more volume of the lipid plaque subjected to high VMS than those of the other two models. Based on the obtained results, we may infer that the short stenting (i.e., LAM) may aggravate vascular injury due to high VMS on the artery-stent interaction surface and within the lipid plaque. Therefore, to obtain a better outcome, a longer stent, rather than a short one, might be needed for arterial stenting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. Drug-Coated Balloon Angioplasty: A Novel Treatment for Pulmonary Artery In-Stent Stenosis in a Patient with Williams Syndrome.

    Science.gov (United States)

    Cohen, Jennifer L; Glickstein, Julie S; Crystal, Matthew A

    2017-12-01

    A 20-month-old boy with Williams syndrome had undergone multiple surgical and catheter-based interventions for resistant peripheral pulmonary arterial stenoses with eventual bilateral stent placement and conventional balloon angioplasty. He persistently developed suprasystemic right ventricular (RV) pressure. Angioplasty with a drug-coated balloon (DCB) was performed for in-stent restenosis and to remodel his distal pulmonary vessels bilaterally. This resulted in immediate improvement in the in-stent stenosis and resultant decrease in RV pressure. Follow-up catheterization two months later continued to show long-lasting improvement in the in-stent stenosis. We hypothesize that the anti-proliferative effects of DCBs may be of benefit in the arteriopathy associated with Williams syndrome. We report this as a novel use of a DCB in the pulmonary arterial circulation in a patient with Williams syndrome.

  10. Outcome of Carotid Artery Stenting for Radiation-Induced Stenosis

    International Nuclear Information System (INIS)

    Dorresteijn, Lucille; Vogels, Oscar; Leeuw, Frank-Erik de; Vos, Jan-Albert; Christiaans, Marleen H.; Ackerstaff, Rob; Kappelle, Arnoud C.

    2010-01-01

    Purpose: Patients who have been irradiated at the neck have an increased risk of symptomatic stenosis of the carotid artery during follow-up. Carotid angioplasty and stenting (CAS) can be a preferable alternative treatment to carotid endarterectomy, which is associated with increased operative risks in these patients. Methods and Materials: We performed a prospective cohort study of 24 previously irradiated patients who underwent CAS for symptomatic carotid stenosis. We assessed periprocedural and nonprocedural events including transient ischemic attack (TIA), nondisabling stroke, disabling stoke, and death. Patency rates were evaluated on duplex ultrasound scans. Restenosis was defined as a stenosis of >50% at the stent location. Results: Periprocedural TIA rate was 8%, and periprocedural stroke (nondisabling) occurred in 4% of patients. After a mean follow-up of 3.3 years (range, 0.3-11.0 years), only one ipsilateral incident event (TIA) had occurred (4%). In 12% of patients, a contralateral incident event was present: one TIA (4%) and two strokes (12%, two disabling strokes). Restenosis was apparent in 17%, 33%, and 42% at 3, 12, and 24 months, respectively, although none of the patients with restenosed vessels became symptomatic. The length of the irradiation to CAS interval proved the only significant risk factor for restenosis. Conclusions: The results of CAS for radiation-induced carotid stenosis are favorable in terms of recurrence of cerebrovascular events at the CAS site.

  11. No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis-results from a linkage study

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Engkilde, Kåre; Menné, Torkil

    2011-01-01

    Background. Percutaneous coronary intervention (PCI) with implantation of a metal stent is a common procedure performed in patients with symptomatic ischaemic heart disease. Intracoronary stents typically have a backbone of stainless steel, which contains nickel, chromium, and molybdenum, and it ......Background. Percutaneous coronary intervention (PCI) with implantation of a metal stent is a common procedure performed in patients with symptomatic ischaemic heart disease. Intracoronary stents typically have a backbone of stainless steel, which contains nickel, chromium, and molybdenum......, and it remains unclear whether individuals who are allergic to these metals have an increased risk of restenosis after PCI with stent implantation. Objectives. To further evaluate whether dermatitis patients with nickel and/or chromium allergy had an increased risk of developing cardiac in-stent restenosis...... with stainless steel stents. Methods. An individual-level linkage study was performed to identify dermatitis patients who had been patch tested with the European baseline series between 1979 and 2007 at Gentofte University Hospital (N = 18794) and who had also undergone PCI at some point in a Danish hospital...

  12. Evaluation of the small intestinal submucosa covered stent in preventing restenosis after percutaneous transluminal angioplasty in the swine

    International Nuclear Information System (INIS)

    Wang Xiaobai; Li Jinglei; Zhang Hong; Zhang Yan

    2012-01-01

    Objective: To compare the performance of small intestinal submucosa (SIS)-covered endografts (SCEs) to bare nitinol stents (BSs) in injured swine iliac arteries. Materials and methods: Twenty-eight nitinol stents were used: 14 externally SCEs and 14 BSs. Devices were implanted in each side of balloon-injured external iliac arteries of 14 swine via carotid approach. Arteriograms were obtained before and after implantation and before animal sacrifice at 4, 8, and 12 weeks. Histopathological and electron microscopy studies of explanted specimens were performed. Results: Implantation of all SCEs and BSs was technically successful, but one SCE and one BS were obstructed at 8 weeks after implantation. At sacrifice, the other 26 stents were patent, with angiogram showing no significant different luminal narrowing between SCEs and BSs. Proliferating cell nuclear antigen (PCNA) immunohistochemistry examination revealed that the percentage of PCNA(+) cells were lower in SCEs (p < 0.05). Additionally, histomorphological analysis indicated that the neointima area and percentage of narrowing area were greater in SCEs, but there was no statistical significance. Greater endothelial cell count in SCEs than in BSs per visual field at 4000 times magnification by scanning electron microscope (p < 0.05). Conclusion: Compared to BSs, no definite decrease of neointima and restenosis was found in SCEs in the present study. However, it is effective in promoting endothelial regeneration and strengthening endothelial function.

  13. XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent

    NARCIS (Netherlands)

    Beijk, Marcel A. M.; Piek, Jon J.

    2007-01-01

    Drug-eluting stents (DES) have been shown to be safe and significantly reduce clinical events and angiographic restenosis in the percutaneous treatment of coronary artery disease. Currently, three DES have been approved in Europe and Northern America: the sirolimus-eluting stent (SES), the

  14. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    Science.gov (United States)

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  15. In vitro stent lumen visualisation of various common and newly developed femoral artery stents using MR angiography at 1.5 and 3 tesla.

    Science.gov (United States)

    Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K

    2013-02-01

    To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.

  16. Percutaneous transluminal angioplasty and stent placement for iliofemoral arterial atherosclerotic occlusive disease

    International Nuclear Information System (INIS)

    Zheng Yanbo; Jiang Wenjin; Liu Sheng; Song Xuepeng; Sheng Qirui

    2006-01-01

    Objectives: To assess the safety and efficacy of percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of iliofemoral arterial atherosclerotic occlusive diseases. Methods From April 1999 to August 2004, 13 cases of iliofemoral arterial occlusions were recanalized with contact thrombolytic therapy combined with guide wire mechanical recanalization method, followed by angioplasty and stent placement. A total of 25 self-expanding Wallstents were deployed. All patients were followed up by means of duplex ultrasound, angiography, or both. Results: All 13 cases were successfully recanalized, with technical successful rate of 100%. Available follow-up for all patients from 8 months-5 years (mean 26.2 months) included one patient undergoing again with successful contact thrombolysis because of early thrombosis; another patient with recurrent symptoms at 19 month after operation undertaking surgical bypass because of later reocclusion; all of the rest stents showing patency by the end of the study. Conclusions: Contact thrombolysis combined with guide wire mechanical recanalization for iliofemoral arterial occlusion is safe and effective, whereas PTA and stent placement would have the nearly same efficacy for the disease with mild injury and low restenosis. (authors)

  17. Clinical presentation and outcomes of coronary in-stent restenosis across 3-stent generations.

    Science.gov (United States)

    Magalhaes, Marco A; Minha, Sa'ar; Chen, Fang; Torguson, Rebecca; Omar, Al Fazir; Loh, Joshua P; Escarcega, Ricardo O; Lipinski, Michael J; Baker, Nevin C; Kitabata, Hironori; Ota, Hideaki; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-12-01

    Clinical presentation of bare metal stent in-stent restenosis (ISR) in patients undergoing target lesion revascularization is well characterized and negatively affects on outcomes, whereas the presentation and outcomes of first- and second-generation drug-eluting stents (DESs) remains under-reported. The study included 909 patients (1077 ISR lesions) distributed as follows: bare metal stent (n=388), first-generation DES (n=425), and second-generation DES (n=96), categorized into acute coronary syndrome (ACS) or non-ACS presentation mode at the time of first target lesion revascularization. ACS was further classified as myocardial infarction (MI) and unstable angina. For bare metal stent, first-generation DES and second-generation DES, ACS was the clinical presentation in 67.8%, 71.0%, and 66.7% of patients, respectively (P=0.470), whereas MI occurred in 10.6%, 10.1%, and 5.2% of patients, respectively (P=0.273). The correlates for MI as ISR presentation were current smokers (odds ratio, 3.02; 95% confidence interval [CI], 1.78-5.13; Ppresentations had an independent effect on major adverse cardiac events (death, MI, and re-target lesion revascularization) at 6 months (MI versus non-ACS: adjusted hazard ratio, 4.06; 95% CI, 1.84-8.94; Pclinical presentation is similar irrespective of stent type. MI as ISR presentation seems to be associated with patient and not device-related factors. ACS as ISR presentation has an independent effect on major adverse cardiac events, suggesting that ISR remains a hazard and should be minimized. © 2014 American Heart Association, Inc.

  18. Genetic variants in CCNB1 associated with differential gene transcription and risk of coronary in-stent restenosis

    NARCIS (Netherlands)

    Silvestre-Roig, Carlos; Fernández, Patricia; Mansego, María L.; van Tiel, Claudia M.; Viana, Rosa; Anselmi, Chiara Viviani; Condorelli, Gianluigi; de Winter, Robbert J.; Martín-Fuentes, Paula; Solanas-Barca, María; Civeira, Fernando; Focaccio, Amelia; de Vries, Carlie J. M.; Chaves, Felipe Javier; Andrés, Vicente

    2014-01-01

    The development of diagnostic tools to assess restenosis risk after stent deployment may enable the intervention to be tailored to the individual patient, for example, by targeting the use of drug-eluting stent to high-risk patients, with the goal of improving safety and reducing costs. The CCNB1

  19. Percutaneous stenting of the superior mesenteric artery for the treatment of chronic mesenteric ischemia

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Suh, Sang Hyun; Won, Jong Yun; Lee, Do Yun; Kim, Sam Soo

    2008-01-01

    We wanted to evaluate the effectiveness of stent placement on the superior mesenteric artery as a treatment for chronic mesenteric ischemia. Seven patients (mean age: 55 years, age range: 43-66 years) with chronic mesenteric ischemia were enrolled between March 2000 and September 2003. All the patients underwent pre-procedure contrast enhanced computerized tomography to evaluate for occlusion or stenosis of the mesenteric arteries and they then underwent an angiographic procedure. A balloon-expandable metal stent was placed in the superior mesenteric artery, and this was combined with balloon angioplasty and thrombolysis. We evaluated the angiographic and procedural success after the procedures. Angiographic and procedural success was obtained in 100% of the patients and the clinical symptoms improved in 100% of the patients. The patency at 6-months and 1-year was 85% and 71%, respectively. The mean follow-up period was 12 months (range: 1-25 months). During the follow-up period, ischemic symptoms recurred in 2 patients, and restenosis in a stent was confirmed with angiography; one patient was successfully treated by stent placement in the celiac artery and the other patient died due to extensive mesenteric thrombosis. For the treatment of chronic mesenteric ischemia, percutaneous stent placement on the superior mesenteric artery showed a favorable result and it was an effective alternative to surgery for the high-risk patients

  20. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p 1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    Science.gov (United States)

    Floren, Michael G; Günther, Rolf W; Schmitz-Rode, Thomas

    2004-05-01

    To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The field strength was set to a maximum of 90 kA/m within a frequency range from 80 kHz to 320 kHz. The electromagnetic field was emitted by a custom-made water-cooled copper winding antenna. A flow model for stent heating was set up to assess the increase in temperature of an expanded 316L stainless steel stent with typical coronary stent dimensions of 3.5 mm diameter and 14.5 mm in length, and in a second setup with 4.5 mm diameter and 13 mm in length, respectively. The stent was located in a bioartificial artery, simulated by a fibrinogen matrix with a defined number of vital cells. The system was exposed to a pulsating perfusion and to an electromagnetic field of 200 kHz over a period of 20 minutes and in a second setup to an electromagnetic field of 300 kHz and increasing intensity up to maximum power-output. Afterward, the artificial vessel was sliced and examined by fluorescence microscopy to evaluate the number and location of damaged cells. The calorimetric tests show an exponential correlation of energy uptake in the stent with an increase in frequency and a constant generator output. At a frequency of 80 kHz, the power uptake accounts for 0.1 W (250 kHz 1.0 W; 320 kHz 1.9 W, respectively). The flow tests confirmed feasibility to elevate the stent temperature from 37 degrees C body temperature to 44 degrees C at 200 kHz within 55 seconds. The temperature increase of the fluid passing the heated vessel region was only marginal (maximum of 0.5 degrees C). Cell necrosis after 20 minutes of treatment was not observed. In a second set-up with 4.5 mm stent diameter, a frequency of 300 kHz and with maximum power output, the stent temperature was increased to 80 degrees C and there was

  2. Clinical results of Intracoronary Brachytherapy (ICBT) for multiple in-stent restenosis

    International Nuclear Information System (INIS)

    Stadler, P.; Schaefer, C.; Chaber, S.; Putnik, K.; Treutwein, M.; Koelbl, O.; Muders, F.

    2006-01-01

    Background and purpose: treatment of in-stent restenosis (ISR) with percutaneous coronary intervention (PCI) alone is often followed by early re-restenosis. The present study focused on the effect of intracoronary brachytherapy (ICBT) on multiple in-stent restenosis (MISR) after repeated PCI. Patients and methods: 40 patients (27 male, 13 female, age: 66 ± 9 years) with MISR (two to six ISRs, median three ISRs) were retrospectively analyzed. All patients were treated by using the Novoste registered Beta-Cath trademark 3.5F System after PCI. The target vessel received 18.4-25.3 Gy of radiation at a depth of 2 mm from the center of the source. The restenosis-free survival and overall survival were calculated by Kaplan-Meier analysis (log-rank). The time interval between last PCI without ICBT and the consecutive recurrence was compared with the follow-up time after PCI with ICBT. Results: the 3-year overall survival rate after ICBT was 93%. The 0.5-, 1-, 2-, and 3-year ISR-free survival rates after PCI + ICBT were 81%, 72%, 52%, and 38%, respectively. After PCI alone, the 0.5-, 1-, and 2-year ISR-free survival rates were 30%, 13%, and 0%, respectively. This difference was highly significant (p < 0.0001). Patients with more than three ISRs before ICBT had a better outcome (3-year ISR-free survival: 80%) than patients with only two or three ISRs before ICBT (3-year ISR-free survival: 25%; p < 0.05). Conclusion: ICBT is highly effective and safe in patients with ISR. The results of this study are in accordance with the WRIST and BETA-WRIST data. After 6 months both studies revealed an ISR-free survival rate of 86% (WRIST) and 66% (BETA-WRIST), respectively. The ISR rates in the own control group (70%) were comparable to the placebo groups in WRIST (68%) and BETA-WRIST (72%). Interestingly, patients with more than three ISRs before ICBT had the lowest ISR rate after ICBT. (orig.)

  3. Microfocal X-ray computed tomography post-processing operations for optimizing reconstruction volumes of stented arteries during 3D computational fluid dynamics modeling.

    Science.gov (United States)

    Ladisa, John F; Olson, Lars E; Ropella, Kristina M; Molthen, Robert C; Haworth, Steven T; Kersten, Judy R; Warltier, David C; Pagel, Paul S

    2005-08-01

    Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been conducted at a resolution sufficient to detect subtle alterations in vascular geometry caused by the stent and the subsequent temporal development of NH. We present the details and limitations of a series of post-processing operations used in conjunction with microfocal X-ray CT imaging and reconstruction to generate geometrically accurate flow domains within the localized region of a stent several weeks after implantation. Microfocal X-ray CT reconstruction volumes were subjected to an automated program to perform arterial thresholding, spatial orientation, and surface smoothing of stented and unstented rabbit iliac arteries several weeks after antegrade implantation. A transfer function was obtained for the current post-processing methodology containing reconstructed 16 mm stents implanted into rabbit iliac arteries for up to 21 days after implantation and resolved at circumferential and axial resolutions of 32 and 50 microm, respectively. The results indicate that the techniques presented are sufficient to resolve distributions of WSS with 80% accuracy in segments containing 16 surface perturbations over a 16 mm stented region. These methods will be used to test the hypothesis that reductions in normalized wall shear stress (WSS) and increases in the spatial disparity of WSS immediately after stent implantation may spatially correlate with the temporal development of NH within the stented region.

  4. Complication rate in unprotected carotid artery stenting with closed-cell stents

    International Nuclear Information System (INIS)

    Tietke, Marc W.K.; Kerby, Tina; Alfke, Karsten; Riedel, Christian; Rohr, Axel; Jensen, Ulf; Jansen, Olaf; Zimmermann, Phillip; Stingele, Robert

    2010-01-01

    The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable. (orig.)

  5. Distinctive effects of CD34- and CD133-specific antibody-coated stents on re-endothelialization and in-stent restenosis at the early phase of vascular injury

    Science.gov (United States)

    Wu, Xue; Yin, Tieying; Tian, Jie; Tang, Chaojun; Huang, Junli; Zhao, Yinping; Zhang, Xiaojuan; Deng, Xiaoyan; Fan, Yubo; Yu, Donghong; Wang, Guixue

    2015-01-01

    It is not clear what effects of CD34- and CD133-specific antibody-coated stents have on re-endothelialization and in-stent restenosis (ISR) at the early phase of vascular injury. This study aims at determining the capabilities of different coatings on stents (e.g. gelatin, anti-CD133 and anti-CD34 antibodies) to promote adhesion and proliferation of endothelial progenitor cells (EPCs). The in vitro study revealed that the adhesion force enabled the EPCs coated on glass slides to withstand flow-induced shear stress, so that allowing for the growth of the cells on the slides for 48 h. The in vivo experiment using a rabbit model in which the coated stents with different substrates were implanted showed that anti-CD34 and anti-CD133 antibody-coated stents markedly reduced the intima area and restenosis than bare mental stents (BMS) and gelatin-coated stents. Compared with the anti-CD34 antibody-coated stents, the time of cells adhesion was longer and earlier present in the anti-CD133 antibody-coated stents and anti-CD133 antibody-coated stents have superiority in re-endothelialization and inhibition of ISR. In conclusion, this study demonstrated that anti-CD133 antibody as a stent coating for capturing EPCs is better than anti-CD34 antibody in promoting endothelialization and reducing ISR. PMID:26813006

  6. Computational hemodynamics of an implanted coronary stent based on three-dimensional cine angiography reconstruction.

    Science.gov (United States)

    Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C

    2005-01-01

    Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.

  7. Angiographic patterns of in-stent restenosis classified by computed tomography in patients with drug-eluting stents: correlation with invasive coronary angiography

    International Nuclear Information System (INIS)

    Pan, Jingwei; Lu, Zhigang; Wei, Meng; Zhang, Jiayin; Li, Minghua

    2013-01-01

    To evaluate the diagnostic accuracy of Mehran's in-stent restenosis (ISR) classification by coronary computed angiography (CCTA), with reference to invasive coronary angiography (ICA). Consecutive symptomatic patients, who had clinically suspected ISR and implanted stent diameter ≥ 3 mm, were prospectively enrolled in our study. Mehran's classification was employed by CCTA and ICA to classify ISR lesions into four subtypes: focal, diffuse intrastent, diffuse proliferative and total occlusion. CCTA and ICA measurement of lesion length was further compared. Sixty-one patients with 101 implanted stents were included in our study. The overall sensitivity, specificity, PPV and NPV of CCTA diagnosis of binary ISR, as shown by patient-based analysis (n = 61), were 100 % (49/49), 75 % (8/12), 92.45 % (49/53) and 100 % (8/8) respectively. Mehran's classification of CCTA correlated well with ICA findings. The diagnostic accuracy of CCTA for class I, class II, class III and class IV lesions was 92.5 %, 91.67 %, 100 % and 100 % respectively. Lesion length was assessed to be significantly longer with CCTA than with ICA (11.03 ± 5.89 mm versus 8.56 ± 4.99 mm, P < 0.001). Angiographic patterns of in-stent restenosis can be accurately classified by coronary computed angiography. The lesion length measured by CCTA is longer than that assessed by invasive coronary angiography. (orig.)

  8. Simple balloon dilation for drug-eluting in-stent restenosis: An optical coherent tomography analysis

    Energy Technology Data Exchange (ETDEWEB)

    Arikawa, Ryo [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Yamaguchi, Hiroshi, E-mail: hyamaguchi@tsm.bbiq.jp [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Takaoka, Junichiro; Miyamura, Akihiro; Atsuchi, Nobuhiko; Ninomiya, Toshiko; Atsuchi, Yoshihiko [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Ohishi, Mitsuru [Department of Cardiovascular Medicine and Hypertension, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima (Japan); Terashima, Mitsuyasu [Department of Cardiology, Toyohashi Heart Center, Toyohashi (Japan); Kaneda, Hideaki [Okinaka Memorial Institute for Medical Research, Tokyo (Japan)

    2015-01-15

    Background: Although drug-eluting stent (DES) has significantly reduced restenosis, the treatment of DES-in-stent restenosis (ISR) remains a challenge with high restenosis rate. Methods: We examined whether morphologic appearance of restenosis tissue by optical coherent tomography (OCT) had an impact on outcomes after balloon angioplasty for DES-ISR. The morphologic appearance of restenosis tissue was qualitatively assessed for tissue structures such as homogeneous, layered, and heterogeneous patterns. Results: Using OCT, 50 patients with DES-ISR were divided into 2 groups: 25 lesions with homogeneous or layered patterns (homo/layered group) and 25 lesions with heterogeneous patterns (hetero group). Acute gain was larger in the hetero group (1.33 ± 0.41 mm vs. 1.06 ± 0.32 mm in the homo/layered group, P = 0.03). On intravascular ultrasound analysis, post-procedural percent neointimal area was smaller in the hetero group (27.4 ± 9.2% vs. 34.0 ± 11.2% in the homo/layered group, P = 0.05). Angiographic follow-up was performed in 37 lesions (74%). Follow-up minimal lumen diameter was larger in the hetero group (1.75 ± 0.89 mm vs. 1.01 ± 0.81 mm in the homo/layered group, P = 0.04). Target lesion revascularization rates tended to be lower in the hetero group (20% vs. 43% in the homo/layered group, P = 0.12). Conclusions: Balloon angioplasty was more effective for DES-ISR with heterogeneous tissue appearance than DES-ISR with homogeneous/layered tissue appearance. OCT assessment of DES-ISR morphology may be a useful adjunct in determining clinical strategies. Simple balloon dilatation is a possible treatment strategy for DES-ISR lesions with a heterogeneous appearance on OCT images.

  9. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  10. Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study.

    Science.gov (United States)

    Nakamura, M; Yock, P G; Bonneau, H N; Kitamura, K; Aizawa, T; Tamai, H; Fitzgerald, P J; Honda, Y

    2001-05-01

    Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard stent deployment techniques. The vessel volume (VV), lumen volume (LV), and volume bordered by the stent (SV) were measured using Simpson's method. The volume of plaque and neointima outside the stent (peri-stent volume, PSV) and volume of neointima within the stent (intrastent volume) were also measured. The change of each parameter during the follow-up period (follow-up minus poststent) was calculated and then divided by SV to normalize these values (designated as percent change [%]). As expected, %PSV directly correlated with %VV (Pexterior to a coronary stent occurs to a variable degree after stent implantation. There is a distinct trade-off between positive remodeling and in-stent hyperplasia: in segments in which the degree of peri-stent remodeling is less, intrastent neointimal proliferation is greater and accompanied by more significant late lumen loss.

  11. Experimental 16-row CT evaluation of in-stent restenosis using new stationary and moving cardiac stent phantoms: experimental examination

    International Nuclear Information System (INIS)

    Yamamura, J.; Adam, G.; Begemann, P.G.; Stevendaal, U. van; Grass, M.; Koester, R.

    2006-01-01

    Purpose: The aim of this study was to evaluate in-stent restenosis using a newly developed stationary and moving cardiac stent phantom with three built-in artificial stenoses and a 16-row MDCT. Materials and Methods: A newly developed coronary stent phantom with three artificial stenoses - low (approx. 30%), medium (approx. 50%) and high (approx. 70%) - was attached to a moving heart phantom and used to evaluate the ability of 16-row MDCT to visualize in-stent restenosis. High resolution scans (16 x 0.75 mm, 250 mm FOV) were made to identify the baseline for image quality. The non-moving phantom was scanned (16 x 0.75 mm, routine cardiac scan protocol) first without and then with implementation of an ECG signal at various simulated heart rates (HR 40 to 120 bpm) and pitches (0.15 to 0.3). The moving cardiac phantom was scanned at the same simulated heart rates but at a pitch of 0.15. Images were reconstructed at every 10% of the RR interval using a multi-cycle real cone-beam reconstruction algorithm. Multi-planar reformations (MPR) were made for the image evaluation. The image quality was assessed using a three-point scale, and stent patency and stenoses detection were evaluated using a four-point scale. To evaluate the image quality and to grade the stent stenoses, the median values were calculated while considering the reconstruction interval. Results: The image quality for the static phantom was adequate in 97% of the measurements. In this phantom, every stenosis was detected independent of the pitch and heart rate used. The dynamic stent phantom yielded the best results at 0%, 40%, and 50% of the RR interval at a pitch of 0.15. The low stenosis was visible at a simulated heart rate of up to 80 bpm. Patency can be detected at heart rates greater than 80 bpm. (orig.)

  12. Biomimicry, vascular restenosis and coronary stents.

    Science.gov (United States)

    Schwartz, R S; van der Giessen, W J; Holmes, D R

    1998-01-01

    Biomimicry is in its earliest stages and is being considered in the realm of tissue engineering. If arterial implants are to limit neointimal thickening, purely passive structures cannot succeed. Bioactivity must be present, either by pharmacologic intervention or by fabricating a 'living stent' that contains active cellular material. As tissue engineering evolves, useful solutions will emerge from applying this knowledge directly to vascular biologic problems resulting from angioplasty, stenting, and vascular prosthesis research.

  13. Clinical experience in coronary stenting with the Vivant Z Stent.

    Science.gov (United States)

    Chee, K H; Siaw, F S; Chan, C G; Chong, W P; Imran, Z A; Haizal, H K; Azman, W; Tan, K H

    2005-06-01

    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.

  14. Stenting for peripheral artery disease of the lower extremities: an evidence-based analysis.

    Science.gov (United States)

    2010-01-01

    to evaluate arterial flow in blood vessels. The value of the ABI can provide an assessment of the severity of the disease. Other non invasive imaging techniques include: Computed Tomography (CT) and Magnetic Resonance Angiography (MRA). Definitive diagnosis of PAD can be made by an invasive catheter based angiography procedure which shows the roadmap of the arteries, depicting the exact location and length of the stenosis / occlusion. Angiography is the standard method against which all other imaging procedures are compared for accuracy. More than 70% of the patients diagnosed with PAD remain stable or improve with conservative management of pharmacologic agents and life style modifications. Significant PAD symptoms are well known to negatively influence an individual quality of life. For those who do not improve, revascularization methods either invasive or non-invasive can be used to restore peripheral circulation. TECHNOLOGY UNDER REVIEW: A Stent is a wire mesh "scaffold" that is permanently implanted in the artery to keep the artery open and can be combined with angioplasty to treat PAD. There are two types of stents: i) balloon-expandable and ii) self expandable stents and are available in varying length. The former uses an angioplasty balloon to expand and set the stent within the arterial segment. Recently, drug-eluting stents have been developed and these types of stents release small amounts of medication intended to reduce neointimal hyperplasia, which can cause re-stenosis at the stent site. Endovascular stenting avoids the problem of early elastic recoil, residual stenosis and flow limiting dissection after balloon angioplasty. In individuals with PAD of the lower extremities (superficial femoral artery, infra-popliteal, crural and iliac artery stenosis or occlusion), is primary stenting more effective than percutaneous transluminal angioplasty (PTA) in improving patency?In individuals with PAD of the lower extremities (superficial femoral artery, infra

  15. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    Science.gov (United States)

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  16. Brachytherapy for coronary restenosis: state of art in 2003

    International Nuclear Information System (INIS)

    Latorzeff, I.; Delannes, M.; Latorzeff, I.; Carrie, D.; Alibelli, M.J.; Bonnet, J.; Duthil, P.

    2003-01-01

    Based on therapeutic approach for benign diseases, vascular brachytherapy decreases smooth vascular muscle cells proliferation and multiplication which lead to the formation of the neo-intima. The radioactive positive action affects arterial recoil due to post angioplasty vessel injury. Randomized studies has shown good angiographic results up to 6 months of follow-up, with 50% in-stent restenosis rate decrease and on the analysed segment as well. Decrease on Mace and TLR show statistically significance. Results don't correlate with emitter and beta emitters had been introduced in France recently. Vascular brachytherapy is actually indicated for in-stent restenosis, there is no evidence to perform this treatment for de novo lesion. Geographic miss, source centering, late thrombosis and pullback procedure may interfere with treatment quality. IVUS allows best target volume determination to a higher quality level. Internationals guidelines such as Eva-Gec-Estro recommendations could increase treatment safety and enable development of an optimal technique. (authors)

  17. Toxic vessel reaction to an absorbable polymer-based paclitaxel-eluting stent in pig coronary arteries.

    Science.gov (United States)

    Jabara, Refat; Chronos, Nicolas; Tondato, Fernando; Conway, Damian; Molema, Warner; Park, Kenneth; Mabin, Tom; King, Spencer; Robinson, Keith

    2006-08-01

    The goal of this study was to evaluate a new drug-eluting stent (DES) comprising a bioabsorbable polymer eluting a moderate dose of paclitaxel in a clinically relevant animal model. Although DES limit restenosis, adverse vascular pathologies and toxicities continue to be of major concern. Optimization of DES components, especially completely absorbable polymers, may reduce these toxicities. Bare-metal (BM), absorbable polymer coating only (POLY), and polymer-based paclitaxel-eluting (PACL) stents were implanted in porcine coronary arteries using intravascular ultrasound (IVUS) to optimize stent apposition. The dose density of paclitaxel was 0.30-0.35 mcg/mm2, with in vitro elution studies demonstrating a gradual elution over 6-8 weeks. The animals were terminated at 1 week, 1 month and 3 months. Histopathologic and histomorphometric analyses were perform. The arteries with PACL showed extensive smooth muscle cell necrosis at 1 week and poor apposition of stent struts at 1 month (malapposition measured as gap width between strut and internal elastic lamina), with greater gap width compared to the BM and POLY groups (0.22 mm +/- 0.02 vs. 0.03 mm +/- 0.02 and 0.02 mm +/- 0.01, respectively; p stent malapposition and late neointimal thickening. Since the therapeutic window for paclitaxel may be narrower than currently inferred, thorough preclinical testing coupled with the polymer development process for stents eluting paclitaxel is needed.

  18. Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.

    Science.gov (United States)

    Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma

    2016-01-01

    Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.

  19. Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging.

    Science.gov (United States)

    Haworth, Kevin J; Raymond, Jason L; Radhakrishnan, Kirthi; Moody, Melanie R; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E; Kim, Hyunggun; McPherson, David D; Holland, Christy K

    2016-02-01

    Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. Copyright © 2016 World Federation for

  20. Left-main restenosis in the DES era-a call for action.

    Science.gov (United States)

    di Palma, Gaetano; Cortese, Bernardo

    2017-11-10

    Percutaneous treatment of the unprotected left main trunk (ULM), defined as a vessel without patent bypass graft either to the left circumflex (LCX) or left anterior descending (LAD) artery, has gained a precise role thanks to recent scientific evidence. Although new generation drug-eluting stents have already proven to be safer, there is still a consistent risk of restenosis and late adverse events. The optimal management of a ULM restenosis is still debated. Here we aim at presenting a review of the available data in literature and show our choice for treating it. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Coronary In-Stent Restenosis: Assessment with Corrected Coronary Opacification Difference across Coronary Stents Measured with CT Angiography.

    Science.gov (United States)

    Gao, Yang; Lu, Bin; Hou, Zhi Hui; Yu, Fang Fang; Yin, Wei Hua; Wang, Zhi Qiang; Wu, Yong Jian; Mu, Chao Wei; Meinel, Felix G; McQuiston, Andrew D; Schoepf, U Joseph

    2015-05-01

    To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). The CCO difference across coronary stents is related to ISR severity in obstructive ISR in stents smaller than 3 mm in diameter. © RSNA, 2014.

  2. Restenosis of the sigmoid sinus after stenting for treatment of intracranial venous hypertension: case report

    International Nuclear Information System (INIS)

    Tsumoto, T.; Miyamoto, T.; Shimizu, M.; Inui, Y.; Nakakita, K.; Hayashi, S.; Terada, T.

    2003-01-01

    We report what we believe to be the first case of restenosis of the sigmoid sinus after stenting, in a 42-year-old man with an arteriovenous malformation with progressive right hemiparesis secondary to venous hypertension. Angiography revealed severe stenosis of the left sigmoid sinus, which was dilated with a self-expandable stent. Six months after the procedure, however, the sinus was again severely stenosed. Intravascular sonography revealed intimal proliferation in the stented sinus. It was dilated percutaneously, and the venous pressure decreased from 51 to 33 mmHg. On sonography, the intimal tissue decreased in thickness and the diameter of the stent enlarged a little. (orig.)

  3. Restenosis of the sigmoid sinus after stenting for treatment of intracranial venous hypertension: case report

    Energy Technology Data Exchange (ETDEWEB)

    Tsumoto, T.; Miyamoto, T.; Shimizu, M.; Inui, Y.; Nakakita, K.; Hayashi, S. [Department of Neurosurgery, Minami Wakayama National Hospital, Wakayama (Japan); Terada, T. [Department of Neurological Surgery, Wakayama Medical University, Wakayama (Japan)

    2003-12-01

    We report what we believe to be the first case of restenosis of the sigmoid sinus after stenting, in a 42-year-old man with an arteriovenous malformation with progressive right hemiparesis secondary to venous hypertension. Angiography revealed severe stenosis of the left sigmoid sinus, which was dilated with a self-expandable stent. Six months after the procedure, however, the sinus was again severely stenosed. Intravascular sonography revealed intimal proliferation in the stented sinus. It was dilated percutaneously, and the venous pressure decreased from 51 to 33 mmHg. On sonography, the intimal tissue decreased in thickness and the diameter of the stent enlarged a little. (orig.)

  4. EFFECT OF STENT ABSORBED c-myc ANTISENSE OLIGODEOXYNUCLEOTIDE ON SMOOTH MUSCLE CELLS APOPTOSIS IN RABBIT CAROTID ARTERY

    Institute of Scientific and Technical Information of China (English)

    张新霞; 崔长琮; 李江; 崔翰斌; 徐仓宝; 朱参战

    2002-01-01

    Objective To investigate the effect of gelatin coated Platinium-Iridium stent absorbed c-myc antisense oligodeoxynucleotide (ASODN) on smooth muscle cells apoptosis in a normal rabbit carotid arteries. Methods Gelatin coated Platinium-Iridium stents were implanted in the right carotid arteries of 32 rabbits under vision. Animals were randomly divided into control group and treated group receiving c-myc ASODN (n=16, respectively). On 7, 14, 30 and 90 days following the stenting procedure ,morphometry for caculation of neointimal area and mean neointimal thickness were performed.The expression of c-myc protein was detected by immunohistochemical method. Apoptotic smooth muscle cells was detected by terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL). Results At 7 and 14 days after stenting,there were no detectable apoptotic cells in both groups. The apoptotic cells occurred in the neointima 30 and 90 days after stenting, and the number of apoptotic cells at 30 days were less [4.50±1.29 vs 25.75±1.89 (number/0.1mm2)] than that at 90 days [13.50±1.91 vs 41.50±6.46 (number/0.1mm2)]. Meanwhile c-myc ASODN induced more apoptotic cells than the control group(P<0.0001). c-myc protein expression was weak positive or negative in treated group and positive in control group.Conclusion c-myc ASODN can induce smooth muscle cells apoptosis after stenting in normal rabbit carotid arteries,and it can be used to prevent in-stent restenosis.

  5. Undilatable Stent Neoatherosclerosis Treated with Ad Hoc Rotational Atherectomy

    Directory of Open Access Journals (Sweden)

    Michael Koutouzis

    2017-01-01

    Full Text Available A middle age woman with known ischemic heart disease and old stents in proximal left anterior descending coronary artery (LAD was admitted to Coronary Care Unit with acute coronary syndrome. The coronary angiography showed one vessel disease with significant restenosis within the previously implanted stents. The lesion was tough and remained undilatable despite high pressure balloon inflation. Eventually, the balloon ruptured creating a massive dissection of the LAD beginning immediately after the distal part of the undilatable lesion. We proceeded with a challenging ad hoc rotational atherectomy of the lesion and finally stenting of the lesion. In-stent restenosis many years after stent implantation is considered to be mainly due to neoatheromatosis compared to intimal hyperplasia, making lesion treatment more difficult and unpredictable.

  6. Endovascular brachytherapy to prevent restenosis after angioplasty; Endovaskulaere Brachytherapie in der Restenoseprophylaxe nach Angioplastie und Stentimplantation: Eine Uebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, W.A.; Bohndorf, K. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie

    2003-02-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [German] Die endovaskulaere Radiotherapie stellt das erste erfolgreiche Therapiekonzept in der Restenoseprophylaxe nach PTA und Stentimplantation dar. Am 3.11.2000 hat die amerikanische Food and Drug Administration erstmalig zwei Brachytherapiegeraete zur Restenoseprophylaxe nach Koronararterien-Stenting zugelassen. Grosse multizentrische, kontrollierte Studien wurden fuer das koronare Stromgebiet mit positiven Ergebnissen publiziert, die Datenlage im peripheren Stromgebiet ist noch ungenuegend. Beta-Strahler bieten Vorteile in der Anwendung, moeglicherweise auch in der Sicherheit, Gamma-Strahler dagegen sind besser klinisch evaluiert. Die primaere Indikation zur endovaskulaeren Brachytherapie

  7. High coronary calcium score and post-procedural CK-MB are noninvasive predictors of coronary stent restenosis

    Directory of Open Access Journals (Sweden)

    Lee JB

    2017-02-01

    Full Text Available Jae-Beom Lee,1 Yun-Seok Choi,2 Woo-Baek Chung,2 Ami Kwon,2 Chul-Soo Park,2 Man-Young Lee2 1Anyang Sam Hospital, 2Division of Cardiology, Department of Internal Medicine, Youido St Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea Purpose: High coronary calcium score (CCS and post-procedural cardiac enzyme may be related with poor outcomes in patients with coronary stent implantation. Methods: A total of 1,072 patients (63.2% male, mean age: 61.7±10.3 years who underwent coronary multi-detect computed tomography at index procedure and follow-up coronary angiography (CAG after drug-eluting stent (DES were divided into two groups: those with and without target lesion revascularization (TLR; >50% reduction in luminal stent diameter or angina symptoms on follow-up CAG. The CCSs for predicting stent revascularization were elucidated. Results: There were no significant differences between the two groups with regard to risk factors. The initial CCS was significantly higher in the TLR group (1,102.4±743.7 vs 345.8±51.05, P=0.04. After adjustment of significant factors for TLR, only CCS and post-procedural creatine kinase MB form (CK-MB elevation were significant predictors of coronary artery TLR. Receiver operation curve revealed that >800 in CCS had 69% in sensitivity and 88% in specificity about predicting the TLR. Conclusion: High CCS with post-procedural CK-MB might be the useful predictors for TLR after DES implantation. Keywords: coronary restenosis, drug-eluting stents, calcium, creatine kinase

  8. New stent design for use in small coronary arteries during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Juan F Granada

    2010-10-01

    Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS

  9. Zotarolimus-eluting stent for the treatment of recurrent, severe carotid artery in-stent stenosis in the TARGET-CAS population.

    Science.gov (United States)

    Tekieli, Lukasz; Pieniazek, Piotr; Musialek, Piotr; Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Trystula, Mariusz; Moczulski, Zbigniew; Dzierwa, Karolina; Paluszek, Piotr; Podolec, Piotr

    2012-06-01

    To evaluate the safety and efficacy of a balloon-mounted drug-eluting stent (DES) for recurrent carotid in-stent stenosis (ISS). As part of our targeted carotid artery stenting (TARGET-CAS) protocol, neurological and ultrasound evaluations have been performed at 3, 6, and 12 months and then annually since 2001 in all carotid stent patients. For angiographically-confirmed >70% ISS, balloon angioplasty was performed as a first-line treatment. Recurrent ISS was treated with a 4.0-mm zotarolimus-eluting coronary stent (ZES) that was postdilated according to intravascular ultrasound imaging. Among the 1350 neuroprotected CAS procedures performed between January 2001 and March 2011, there were 7 (0.52%) patients (5 men; ages 51-72 years), all neurologically asymptomatic, with >70% recurrent ISS that occurred at 5 to 11 months after the initial balloon angioplasty treatment for ISS. ZES implantation under distal embolic protection was technically successful and uncomplicated. Angiographic stenosis was reduced from 84.6%±7.5% to 10.7%±3.6% (p<0.01). In 5 patients with ZES implanted fully within the self-expanding carotid stent, duplex ultrasound follow-up (mean 17 months, range 6-36) revealed no evidence of restenosis or stent fracture/deformation. In the 2 other patients, the ZES had been implanted for distal edge ISS such that the ZES protruded beyond the original carotid stent. This protruding segment of the ZES demonstrated deformation/kinking in both; in one, this led to symptomatic stent occlusion. The use of coronary ZES in the treatment of recurrent carotid ISS is feasible and appears effective provided the ZES is placed entirely within the original stent. Placement of a coronary ZES outside the carotid stent scaffold should be avoided.

  10. [Meta-analysis of percutaneous transluminal atherectomy in the treatment for in-stent restenosis of lower extremity peripheral artery disease].

    Science.gov (United States)

    Li, Weihao; Zhang, Tao; Liu, Yunfeng; Zhang, Yongbao; Li, Qingle; Zhang, Xiaoming; Shen, Chenyang

    2015-11-24

    To evaluate the clinical safety and efficacy of percutaneous transluminal atherectomy for in-stent restenosis (ISR) in patients with low extremity peripheral arterial diseases (PAD). PubMed, Elsevier, EBSCO, Spring databases and Cochrane Library were searched for relevant articles. Based on the different mechanisms of atherectomy, the patients were divided into mechanic atherectomy group and laser atherectomy group. The safety end points included the rate of distal embolism and severe arterial wall injuries. And the efficacy end points included primary patency rate and freedom from target vessel revascularization (TVR-free) 6 months and 12 months after surgery. A total of 9 studies and 620 patients (published between 2006 and 2014) were accepted. The rate of distal embolism was 4.2% (95% confidence interval (CI): 1.7%-6.7%), while that of severe arterial wall injuries was 1.9% (95%CI: 0.9%-3.0%), respectively. Laser atherectomy was responsible for more distal embolism (6.8%) compared to mechanic atherectomy (2.0%), which was significantly different (Q=21.66, P=0.010). At 6-month follow-up, primary patency rate and rate of TVR-free were 63.0% (95% CI: 55.5%-70.6%) and 80.4% (95% CI: 70.5%-90.3%), while at 12-month follow-up were 43.5% (95%CI: 32.2%-54.9%) and 58.0% (95% CI: 52.1%-63.9%), respectively. The free-TVR rate at 6 months follow-up in mechanical atherectomy group was 77.9%, and was inferior to that in laser atherectomy group (80.8%, Q=13.49, P=0.009). Published bias was discovered at the analysis of 12-month TVR-free rate by means of Begg Test (P=0.039). Meta analysis concerned about the 3 randomized controlled trials demonstrated that there was no significant improvement using atherectomy for ISR comparing to standard balloon at 6-month TVR-free rate (OR=1.34, 95% CI: 0.86-2.07, P=0.196). To treat ISR lesion in lower extremities, laser atherectomy has a lower free-TVR rate in the middle term follow-up.A higher rate of distal embolism is noted though. On

  11. The current role of vascular stents.

    Science.gov (United States)

    Busquet, J

    1993-09-01

    The limitations of percutaneous balloon angioplasty have favoured the development and the use of vascular endoprostheses or stents. These thin-walled metal devices maintain after expansion, an optimal and constant diameter for the vascular lumen. Restenosis, dissection, abrupt closure, residual stenosis or re-opened total occlusion represent appropriate indications for stenting. A large experience with non-coronary application of stents is currently available in iliac, femoro-popliteal and renal arteries, aorta, large veins.

  12. Higher plasma level of STIM1, OPG are correlated with stent restenosis after PCI.

    Science.gov (United States)

    Li, Haibin; Jiang, Zhian; Liu, Xiangdong; Yang, Zhihui

    2015-01-01

    Percutaneous Coronary Intervention (PCI) is one of the most effective treatments for Coronary Heart Disease (CHD), but the high rate of In Stent Restenosis (ISR) has plagued clinicians after PCI. We aim to investigate the correlation of plasma Stromal Interaction Molecular 1 (STIM1) and Osteoprotegerin (OPG) level with stent restenosis after PCI. A total of 100 consecutive patients with Coronary Heart Disease (CHD) received PCI procedure were recruited. Coronary angiography was performed 8 months after their PCI. Then patients were divided into 2 groups: observation group was composed by patients who existing postoperative stenosis after intervention; Control group was composed by patients with no postoperative stenosis. The plasma levels of STIM, OPG in all patients were tested before and after intervention. Pearson correlation and multiple linear regression analysis were performed to analysis the correlation between STIM, OPG level and postoperative stenosis. 35 cases were divided into observation group and other 65 were divided into control group. The plasma levels of STIM, OPG have no statistical difference before their PCI procedure, but we observed higher level of High-sensitivity C-reactive protein (Hs-CRP) existed in observation group. We observed higher level of plasma STIM, OPG in observation group when compared with control group after PCI procedure (P PCI, which could provide useful information for the restenosis control after PCI.

  13. One Year Clinical Outcomes of Renal Artery Stenting: The Results of ODORI Registry

    International Nuclear Information System (INIS)

    Sapoval, M.; Tamari, I.; Goffette, P.; Downes, M.; Senechal, Q.; Fanelli, F.; Reimer, P.; Negaiwi, Z.; Cassin, P. De; Heye, S.; Korobov, V.; Tsetis, D.; Abada, H.

    2010-01-01

    The safety, efficacy and long term clinical benefits of renal artery revascularization by stenting are still a matter of debate. The aim of our study was to define the safety and efficacy of renal artery stenting with the Tsunami peripheral stent (Terumo Corporation, Tokyo, Japan). The ODORI was a prospective, multicentre registry which enrolled 251 consecutive patients, (276 renal arteries) in 36 centres across Europe. The primary endpoint was acute procedural success defined as <30% residual stenosis after stent placement. Secondary endpoints included major adverse events, blood pressure control, serum creatinine level, and target lesion revascularization (TLR) at 6 and 12 months. Patients were 70 ± 10 years old, 59% were male, 33% had diabetes, and 96% hypertension. The main indications for renal stent implantation were hypertension in 83% and renal salvage in 39%. Direct stent implantation was performed in 76% of the cases. Acute success rate was 100% with residual stenosis of 2.5 ± 5.4%. Systolic/diastolic blood pressure decreased from a mean of 171/89 at baseline to 142/78 mmHg at 6 months (p < 0.0001 vs. baseline), and 141/80 mmHg at 12 months (p < 0.0001 vs. baseline). Mean serum creatinine concentration did not change significantly in the total population. However, there was significant improvement in the highest tercile (from 283 μmol/l at baseline to 205 and 209 μmol/l at 6 and 12 months respectively). At 12-months, rates of restenosis and TLR were 6.6 and 0.8% respectively. The 12 month cumulative rate of all major clinical adverse events was 6.4% while the rate of device or procedure related events was 2.4%. In hypertensive patients with atherosclerotic renal artery stenosis Tsunami peripheral balloon-expandable stent provides a safe revascularization strategy, with a potential beneficial impact on hypertension control and renal function in the highest risk patients.

  14. Use of Self-Expanding Stents for the Treatment of Vertebral Artery Ostial Stenosis: a Single Center Experience

    International Nuclear Information System (INIS)

    Chung, Sun Young; Lee, Deok Hee; Choi, Jin Woo; Choi, Byung Se; In, Hyun Sin; Kim, Sun Mi; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul

    2010-01-01

    To evaluate our early experience using self-expanding stents to treat atherosclerotic vertebral artery ostial stenosis (VAOS), with respect to technical feasibility and clinical and imaging follow-up results. A total of 20 lesions in 20 patients underwent stenting of the VAOS using a self-expanding stent (Precise RX; Cordis Neurovascular, Miami Lakes, FL). Two patients were asymptomatic. We analyzed the technical success rate, causes of technical failure, occurrence of any vascular or neurological event, and the occurrence of any neurological abnormality or in-stent restenosis (ISR) seen on follow-up. The imaging follow-up was performed with Doppler ultrasound (DUS) as a primary screening modality. One instance of technical failure was caused by failure of the guidewire passage. The stent diameter was 5 mm, and post-stenting balloon dilatations were necessary in all cases. Stent misplacement requiring placement of an additional stent occurred in four cases. Following a 14.8 month average clinical follow-up time, two patients showed anterior circulation ischemia, which was not attributed to the VAOS we treated. Following a 13.7 month average DUS follow-up, five patients showed a mild degree of diffuse or focal intimal thickening in the stent lumen; however, none of the stenosis showed luminal loss of more than 50% and no stent fracture was noted. The use of self-expanding stents for treating VAOS was technically feasible and helped to improve artery patency during our limited follow-up interval

  15. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

    Science.gov (United States)

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-12-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length  1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.

  16. Stent-assisted angioplasty for intracranial atherosclerosis

    International Nuclear Information System (INIS)

    Nakahara, Toshinori; Sakamoto, Shigeyuki; Hamasaki, Osamu; Sakoda, Katsuaki

    2002-01-01

    We report on two patients with intracranial atherosclerosis of the carotid artery or vertebral artery treated with stent-assisted angioplasty. Both patients have severe intracranial atherosclerosis (>70%) with refractory symptoms despite optimal medical treatment. In both patients, a coronary balloon-expandable stent was successfully placed using a protective balloon technique without procedural complications. The patients were asymptomatic and neurologically intact at a mean clinical follow-up of 13 months. Follow-up angiograms did not show restenosis 3 or 4 months after procedure, respectively. Stent-assisted angioplasty for intracranial atherosclerosis in the elective patient has proven effective, with an acceptable low rate of morbidity and mortality. (orig.)

  17. Stent implantation influence wall shear stress evolution

    Science.gov (United States)

    Bernad, S. I.; Totorean, A. F.; Bosioc, A. I.; Petre, I.; Bernad, E. S.

    2016-06-01

    Local hemodynamic factors are known affect the natural history of the restenosis critically after coronary stenting of atherosclerosis. Stent-induced flows disturbance magnitude dependent directly on the strut design. The impact of flow alterations around struts vary as the strut geometrical parameters change. Our results provide data regarding the hemodynamic parameters for the blood flow in both stenosed and stented coronary artery under physiological conditions, namely wall shear stress and pressure drop.

  18. [A Case of Peritoneal Metastasis in Which Colostomy Was Useful for Restenosis after Stenting].

    Science.gov (United States)

    Tagawa, Hiroko; Yoshimatsu, Kazuhiko; Yokomizo, Hajime; Yano, Yuki; Nakayama, Mao; Okayama, Sachiyo; Satake, Masaya; Sakuma, Akiko; Matsumoto, Atsuo; Fujimoto, Takashi; Shiozawa, Shunichi; Shimakawa, Takeshi; Katsube, Takao; Kato, Hiroyuki; Naritaka, Yoshihiko

    2015-11-01

    We report a case of restenosis after performing stenting twice for ileus caused by peritoneal dissemination that occurred after surgery for sigmoid colon cancer, in which colostomy was performed to improve the patient's QOL. The patient was a 58-year-old woman who underwent sigmoidectomy for sigmoid colon cancer. She presented with a peritoneal recurrence 3 times, and the third surgery was a non-curative resection. Chemotherapy was administered but was discontinued because of severe adverse events, and the patient was followed up with the best supportive care. An anastomotic stricture occurred 4 years after the initial surgery, and despite performing stenting twice, stenosis occurred 3 times within a few months. The third stenosis occurred shortly after the second episode, and colostomy was therefore performed. The patient died from cancer 4 months after colostomy without having another episode of stenosis. Although stenting is effective for patients with malignant colon stenosis, colostomy appears to be more effective for repeated post-stenting stenosis, when the patient is in an eligible general condition.

  19. Diagnostic value of myocardial perfusion SPECT in the prediction of restenosis after coronary artery bypass graft surgery

    International Nuclear Information System (INIS)

    Paeng, J. C.; Lee, D. S.; Kang, W. J.; Kim, K. B.; Chung, J. K.; Lee, M. C.

    2002-01-01

    Myocardial SPECT has been reported to be sensitive in the detection of restenosis after revascularization. However, the diagnostic value is not well established in bypass graft surgery (CABG), due to significant influences of characteristics of graft vessels and the time interval between CABG and the SPECT. In this study, we evaluated the diagnostic value of myocardial SPECT for the restenosis after CABG. A total of 160 patients with coronary artery disease (M:F=118:42, 60±8 yr) who had undergone CABG were included. Rest T1-201/ dipyridamole stress Tc-99m-MIBI SPECT was performed 3 months (103±16 days) after CABG. Segmental perfusion was quantified using a 20-segment model, and segments of reversible perfusion defect (REV) were defined. Follow-up coronary angiography was performed 1 year (397±104 days) after CABG. The segments of REV were compared between arterial and venous graft groups. And the diagnostic power of 3-month SPECT was evaluated for the prediction of restenosis. On the 3-month SPECT, 620 segments showed REV. The segments of REV were 37% of artery-grafted segments and 36% of vein-grafted segments (p=n.s.). On 1-year coronary angiography, 113 graft vessels (28%) showed restenosis. The overall sensitivity and specificity of REV on 3-month SPECT for the prediction of restenosis were 46% and 67%, respectively, but 52% and 68%, in artery-graft group. REV detected on 3-month SPECT has a predictive value, especially, high specificity for the prediction of restenosis after CABG, which was more definite in artery-graft group

  20. Optimization of Drug Delivery by Drug-Eluting Stents.

    Directory of Open Access Journals (Sweden)

    Franz Bozsak

    Full Text Available Drug-eluting stents (DES, which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours or very slowly (over periods of several months up to one year at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.

  1. Fat-Suppressed Gadolinium-Enhanced Three-Dimensional Magnetic Resonance Angiography Adequately Depicts the Status of Iliac Arteries Following Atherectomy and Stent Placement

    International Nuclear Information System (INIS)

    Amano, Yasuo; Gemma, Kazuhito; Kawamata, Hiroshi; Kumazaki, Tatsuo

    1998-01-01

    Fat-suppressed, three-dimensional magnetic resonance angiography (3D MRA) was performed on nine patients with 11 iliac artery stenoses following atherectomy or stent placement. The MRA accurately depicted continued patency, restenosis, or aneurysm formation when compared with immediate posttreatment conventional arteriography. Therefore MRA is accurate and can be used independently for clinical decision making

  2. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who we...

  3. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  4. Antirestenotic Effects of a Novel Polymer-Coated D-24851 Eluting Stent. Experimental Data in a Rabbit Iliac Artery Model

    International Nuclear Information System (INIS)

    Lysitsas, Dimitrios N.; Katsouras, Christos S.; Papakostas, John C.; Toumpoulis, Ioannis K.; Angelidis, Charalampos; Bozidis, Petros; Thomas, Christopher G.; Seferiadis, Konstantin; Psychoyios, Nikolaos; Frillingos, Stathis; Pavlidis, Nikolaos; Marinos, Euaggelos; Khaldi, Lubna; Sideris, Dimitris A.; Michalis, Lampros K.

    2007-01-01

    Experimental and clinical data suggest that stents eluting antiproliferative agents can be used for the prevention of in-stent restenosis. Here we investigate in vitro the antiproliferative and apoptotic effect of D-24851 and evaluate the safety and efficacy of D-24851-eluting polymer-coated stents in a rabbit restenosis model (n = 53). Uncoated stents (n = 6), poly (dl-lactide-co-glycolide) (PLGA)-coated stents (n = 7), and PLGA-coated stents loaded with 0.08 ± 0.0025 μM (31 ± 1 μg; low dose; n = 7), 0.55 ± 0.02 μM (216 ± 8 μg; high dose; n = 6), and 4.55 ± 0.1 μM (1774 ± 39 μg; extreme dose; n = 5) of D-24851 were randomly implanted in New Zealand rabbit right iliac arteries and the animals were sacrificed after 28 days for histomorphometric analysis. For the assessment of endothelial regrowth in 90 days, 12 rabbits were subjected to PLGA-coated (n = 3), low-dose (n = 3), high-dose (n = 3), and extreme-dose (n = 3) stent implantation. In vitro studies revealed that D-24851 exerts its growth inhibitory effects via inhibition of proliferation and induction of apoptosis without increasing the expression of heat shock protein-70, a cytoprotective and antiapoptotic protein. Treatment with low-dose D-24851 stents was associated with a significant reduction in neointimal area and percentage stenosis only compared with bare metal stents (38% [P = 0.029] and 35% [P = 0.003] reduction, respectively). Suboptimal healing, however, was observed in all groups of D-24851-loaded stents in 90 days in comparison with PLGA-coated stents. We conclude that low-dose D-24851-eluting polymer-coated stents significantly inhibit neointimal hyperplasia at 28 days through inhibition of proliferation and enhancement of apoptosis. In view of the suboptimal re-endothelialization, longer-term studies are needed in order to establish whether the inhibition of intimal growth is maintained

  5. Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Li Shen

    2015-01-01

    Full Text Available Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES, compared with traditional sirolimus-eluting stent (SES. Methods: Patients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF, and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR by telephone visit and late luminal loss (LLL at 9-month by angiographic follow-up. Results: From July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980. Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028. There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008. Conclusions: After 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.

  6. Bioresorbable scaffolds in the treatment of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Zhang Y

    2013-03-01

    Full Text Available Yaojun Zhang,1,2 Christos V Bourantas,1 Vasim Farooq,1 Takashi Muramatsu,1 Roberto Diletti,1 Yoshinobu Onuma,1 Hector M Garcia-Garcia,1 Patrick W Serruys11Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands; 2Division of Cardiovascular Diseases, Nanjing First Hospital, Nanjing Medical University, Nanjing, People's Republic of ChinaAbstract: Drug-eluting stents have reduced the risk of in-stent restenosis and have broadened the application in percutaneous coronary intervention in coronary artery disease. However, the concept of using a permanent metallic endovascular device to restore the patency of a stenotic artery has inherited pitfalls, namely the presence of a foreign body within the artery causing vascular inflammation, late complications such as restenosis and stent thrombosis, and impeding the restoration of the physiologic function of the stented segment. Bioresorbable scaffolds (BRS were introduced to potentially overcome these limitations, as they provide temporary scaffolding and then disappear, liberating the treated vessel from its cage. Currently, several BRSs are available, undergoing evaluation either in clinical trials or in preclinical settings. The aim of this review is to present the new developments in BRS technology, describe the mechanisms involved in the resorption process, and discuss the potential future prospects of this innovative therapy.Keywords: bioresorbable scaffold, drug-eluting stent, biodegradable, design, mechanism, coronary artery disease

  7. Stents Eluting 6-Mercaptopurine Reduce Neointima Formation and Inflammation while Enhancing Strut Coverage in Rabbits.

    Directory of Open Access Journals (Sweden)

    Matthijs S Ruiter

    Full Text Available The introduction of drug-eluting stents (DES has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC, endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface.Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions.Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation.We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient.

  8. Relationship of serum S1P and HC-II levels with vasoactive substances and cytokines in patients with cerebral vascular restenosis after stent implantation

    Directory of Open Access Journals (Sweden)

    Yong Liu

    2017-04-01

    Full Text Available Objective: To study the relationship of serum sphingosine 1-phosphate (S1P and heparin cofactor II (HCII levels with vasoactive substances and cytokines in patients with cerebral vascular restenosis after stent implantation. Methods: 52 patients who received cerebrovascular stent implantation and developed restenosis in our hospital between May 2012 and December 2015 were collected as observation group, and 40 healthy patients with cerebrovascular stent implantation who had re-examination in our hospital during the same period were selected as control group. ELISA method was used to detect serum S1P and HC-II levels as well as vasoactive substance and inflammatory factor contents. Spearman correlation analysis was used to evaluate the relationship of serum S1P and HC-II levels with vasoactive substances and inflammatory factors. Results: Serum S1P and HC-II levels of observation group were lower than those of control group (P<0.05; serum vasoactive substances endothelin (ET, angiotensin II (AngII and thromboxane B2 (TXB2 contents of observation group were higher than those of control group while nitric oxide (NO content was lower than that of control group (P<0.05; serum inflammatory factors hypersensitive C-reactive protein (hs-CRP, interleukin-1 (IL-1, IL-6, IL-8 and IL-11 contents of observation group were higher than those of control group (P<0.05. Serum S1P and HC-II levels in patients with cerebral vascular restenosis after stent implantation were directly correlated with vasoactive substance and inflammatory factor contents. Conclusion: Serum S1P and HC-II levels decrease in patients with cerebral vascular restenosis after stent implantation, and it is an important cause of cerebral vascular dysfunction and systemic inflammatory response.

  9. Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients

    Science.gov (United States)

    Giacoppo, Daniele; Gargiulo, Giuseppe; Aruta, Patrizia; Capranzano, Piera; Tamburino, Corrado

    2015-01-01

    Study question What is the most safe and effective interventional treatment for coronary in-stent restenosis? Methods In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (either of bare metal stents or drug eluting stents; and either first or recurrent instances) were included. Trials including multiple treatments at the same time in the same group or comparing variants of the same intervention were excluded. Primary endpoints were target lesion revascularisation and late lumen loss, both at six to 12 months. The main analysis was complemented by network subanalyses, standard pairwise comparisons, and subgroup and sensitivity analyses. Study answer and limitations Twenty four trials (4880 patients), including seven interventional treatments, were identified. Compared with plain balloons, bare metal stents, brachytherapy, rotational atherectomy, and cutting balloons, drug coated balloons and drug eluting stents were associated with a reduced risk of target lesion revascularisation and major adverse cardiac events, and with reduced late lumen loss. Treatment ranking indicated that drug eluting stents had the highest probability (61.4%) of being the most effective for target lesion vascularisation; drug coated balloons were similarly indicated as the most effective treatment for late lumen loss (probability 70.3%). The comparative efficacy of drug coated balloons and drug eluting stents was similar for target lesion revascularisation (summary odds ratio 1.10, 95% credible interval 0.59 to 2.01) and late lumen loss reduction (mean difference in minimum lumen diameter 0.04 mm, 95% credible interval −0.20 to 0.10). Risks of death, myocardial infarction, and stent thrombosis were comparable across all treatments, but these analyses were limited by a

  10. On the Possible Interaction Mechanism between Collateral Vessels and Restenosis

    NARCIS (Netherlands)

    Zun, P.S.; Hoekstra, A.G.

    2015-01-01

    Several clinical studies and their meta-analysis suggest that developed collateral vessels in the heart correlate to an increased risk of in-stent restenosis. The possible physiological interaction between the collateral development and in-stent restenosis is investigated in this study. Based on

  11. Two Blades-Up Runs Using the JetStream Navitus Atherectomy Device Achieve Optimal Tissue Debulking of Nonocclusive In-Stent Restenosis: Observations From a Porcine Stent/Balloon Injury Model.

    Science.gov (United States)

    Shammas, Nicolas W; Aasen, Nicole; Bailey, Lynn; Budrewicz, Jay; Farago, Trent; Jarvis, Gary

    2015-08-01

    To determine the number of runs with blades up (BU) using the JetStream Navitus to achieving optimal debulking in a porcine model of femoropopliteal artery in-stent restenosis (ISR). In this porcine model, 8 limbs were implanted with overlapping nitinol self-expanding stents. ISR was treated initially with 2 blades-down (BD) runs followed by 4 BU runs (BU1 to BU4). Quantitative vascular angiography (QVA) was performed at baseline, after 2 BD runs, and after each BU run. Plaque surface area and percent stenosis within the treated stented segment were measured. Intravascular ultrasound (IVUS) was used to measure minimum lumen area (MLA) and determine IVUS-derived plaque surface area. QVA showed that plaque surface area was significantly reduced between baseline (83.9%±14.8%) and 2 BD (67.7%±17.0%, p=0.005) and BU1 (55.4%±9.0%, p=0.005) runs, and between BU1 and BU2 runs (50.7%±9.7%, patherectomy. JetStream Navitus achieved optimal tissue debulking after 2 BD and 2 BU runs with no further statistical gain in debulking after the BU2 run. Operators treating ISR with JetStream Navitus may be advised to limit their debulking to 2 BD and 2 BU runs to achieve optimal debulking. © The Author(s) 2015.

  12. Risk Factors and Clinical Evaluation of Superficial Femoral Artery Stent Fracture: Prote'ge'GPS Stent

    International Nuclear Information System (INIS)

    Lee, Da Un; Kim, Jae Kyu; Jung, Hye Doo; Huh, Tae Wook; Yim, Nam Yeol; Oh, Hyun jun; Choi, Soo Jin Na; Chang, Nam Kyu

    2010-01-01

    To evaluate the occurrence of superficial femoral artery stent fractures, the risk factors of stent fracture, and the relationship between fractures and clinical findings. Of the 38 patients who underwent treatment with Prote'ge'GPS stenting due to arterial occlusions on the superficial femoral artery, 17 also underwent a clinical analysis. Forty-three stents were inserted in the 17 superficial femoral arteries, ranging between 15 and 50 cm in length, with a mean treated length of 26.4 cm (15-50 cm). A fracture was evaluated by taking a PA and lateral simple radiography, as well as a follow-up evaluation accompanied with a CT angiography, DSA, and a color Doppler sonography. The examination involved the assessment of the difference between bone fractures due to length, placement, and frequency. Fractures occurred in 13 of 43 stents (30.2%). A total of 10 (71.4%) occurred in the upper third, compared to 4 (28.6%) in the lower third of the superficial femoral artery. In addition, 10 stents (71.4%) had a single strut fracture, whereas 4 (28.6%) had multiple strut fractures. A stent fracture occurred more frequently when the stents and lesions were longer (p=0.021, 0.012) and the stents were inserted near the joint. However, there was no significant relationship between stent numbers and the fractures (p=0.126). When the stents were inserted along the popliteal artery, a stent fracture occurred more frequently in the lower third of the artery. The stent fractures did not significantly influence the patency rate of the stented artery (p=0.44) Prote'ge'GPS stents in the superficial femoral artery revealed a considerable number of fractures and the fracture frequency showed a significant relationship with the length of stents and lesions. The closer stent insertion was to the joints, the more frequently fractures occurred. There were no evident significant relationships between the presence of stent fractures and the patency of the stented arteries

  13. Solving the Issue of Restenosis After Stenting of Intracranial Stenoses: Experience with Two Thin-Strut Drug-Eluting Stents (DES)—Taxus Element™ and Resolute Integrity™

    Energy Technology Data Exchange (ETDEWEB)

    Kurre, Wiebke, E-mail: wiebke.kurre@gmx.de; Aguilar-Pérez, Marta [Klinikum Stuttgart, Klinik für Diagnostische und Interventionelle Neuroradiologie (Germany); Fischer, Sebastian [Universitätsklinikum Knappschaftskrankenhaus Bochum GmbH, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin (Germany); Arnold, Guy [Klinikverbund Südwest, Klinikum Sindelfingen, Klinik für Neurologie (Germany); Schmid, Elisabeth; Bäzner, Hansjörg [Klinikum Stuttgart, Klinik für Neurologie (Germany); Henkes, Hans [Klinikum Stuttgart, Klinik für Diagnostische und Interventionelle Neuroradiologie (Germany)

    2015-06-15

    PurposeThin-strut, flexible DES are suitable for intracranial stenting and may improve long-term vessel patency. The purpose of this study was to report our experience with two new-generation DES for the treatment of intracranial atherosclerotic disease.Patients and MethodsWe retrospectively reviewed all patients treated with Taxus Element™ or Resolute Integrity™ stent for an intracranial atherosclerotic stenosis between March 2011 and August 2013. Technical success was defined as the ability to deploy the device at the desired location and reduce the degree of stenosis below 50 %. All procedure-related strokes were recorded. Control angiography was scheduled after 6 weeks, 3, 6, and 12 months and yearly thereafter. A luminal narrowing ≥50 % was regarded as a restenosis. Stroke recurrence in the territory of the treated artery was reported.ResultsIn the defined period we treated 101 patients harboring 117 intracranial stenoses. The procedure was successful in 100 (85.5 %) lesions. Procedure-related strokes occurred in 10 (9.9 %) patients with a permanent morbidity in 3 (3.0 %). Follow-up angiography was available for 83 of 100 (83.0 %) successfully treated lesions with an average of 355 days (IQR 153–482 days). Three (3.6 %) asymptomatic restenoses were detected. All occurred after treatment with Resolute Integrity™, none after Taxus Element™ (p = 0.059). New strokes in the territory of the treated artery were encountered in 2 (2.6 %) occasions.ConclusionThin-strut DES improve long-term patency and reduce the risk of subsequent stroke. Differences between devices may exist. Feasibility is comparable to bare-metal balloon-mounted stents and procedure-related strokes occurred within the expected range.

  14. Biodegradable stents made of pure Mg and AZ91 alloy through SPS sintering

    OpenAIRE

    de Oliveira Botelho, Pedro Augusto

    2015-01-01

    The implantation of stents is an effective procedure to unblock the arteries of patients with serious heart problems. Traditionally, stents are made of inert materials such as stainless steel and titanium alloys. It has been shown that the traditional stents can cause restenosis or thrombosis. In recent years the proposal of biodegradable stents is attracting the interest of the industry and the research, since the stent is mechanically needed only in the first year, eliminating the problems ...

  15. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  16. Influence of 103Pd radioactive stent on apoptosis of vascular smooth muscle cells

    International Nuclear Information System (INIS)

    Liu Yingmei; Wu Wei; Chen Xiaochao; Zhang Xuming; Wang Jingfeng; Wei Yulin; Yang Li

    2003-01-01

    Objective: To evaluate the influence of 103 Pd radioactive stent on apoptosis and its relative genes bcl-2 and bax in injured vascular media smooth muscle cells of rabbit abdominal arteries and to investigate the mechanism of 103 Pd radioactive stent for preventing restenosis after angioplasty. Methods: Fifty male New Zealand rabbits were randomized into stent group and 103 Pd stent group. Each group was subdivided into 5 sub-groups. Control group was set up. The study arteries were harvested at 3, 7, 14, 28 and 56 d after stenting and the pathomorphology, apoptosis analysis and in situ hybridization were performed to evaluate the expression of bcl-2 and bax mRNA. Results: The severity of the restenosis in 103 Pd stent group was less than that of stent group. It was most obvious at the 56th day (P 103 Pd stent group had much more apoptosis of vascular smooth muscle cells than stent group did and reached the peak at the 7th day, (14.72±0.53)% vs (12.42±1.13)% (P 103 Pd stent group was much lower than that of stent group at 3 to 28 d. The difference was most obvious at the 28th day after stenting, (18.43± 0.67)% vs (21.55±0.93)% (P 103 Pd stent group was higher than that of stent group, the peak was at the 7th day, (11.17±0.94)% vs (9.30±1.01)%. The ratio of bcl-2/bax in 103 Pd stent group was much lower than that of stent group at 3 to 28 d. Linear correlation analysis showed that there was significant negative correlation between bcl-2 mRNA and apoptosis. Between bax mRNA and apoptosis, the positive correlation was found (P 103 Pd radioactive stent induced more significant apoptosis in vascular media smooth muscle cells by promoting the expression of apoptosis related genes and relieved the expanding of restenosis

  17. Arterial stenting with self-expandable and balloon-expandable endoprostheses

    NARCIS (Netherlands)

    W.J. van der Giessen (Wim); P.W.J.C. Serruys (Patrick); L.J. van Woerkens (L.); K.J. Beatt (Kevin); W.J. Visser (Willy); J.F. Jongkind; R.H. van Bremen (Robert); E. Ridderhof; H. van Loon (Heleen); L.K. Soei (Lou Kie); H.M.M. van Beusekom (Heleen); P.D. Verdouw (Pieter)

    1990-01-01

    textabstractCoronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several

  18. Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a 188Re-MAG3-filled balloon: six-month clinical and angiographic results of R4 registry

    International Nuclear Information System (INIS)

    Moon, D. H.; Oh, S. J.; Park, S. W.; Hong, M. K.; Lee, C. H.; Kim, J. Z.; Park, S. J.; Lee, H. K.

    2000-01-01

    Intracoronary β-irradiation after rotational atherectomy may be a reasonable approach to prevent recurrent in-stent restenosis (ISR). This study was done to evaluate the feasibility and efficacy of β-radiation therapy with a 188 Re-MAG3-filled balloon following rotational atherectomy for ISR. Fifty consecutive patients with diffuse ISR (length >10 mm) in native coronary arteries underwent rotational atherectomy and adjunctive balloon angioplasty followed by β-irradiation using 188 Re-MAG3-filled balloon catheter. The radiation doses was 15 Gy at 1.0 mm deep into vessel wall. Mean length of the lesion and irradiated segment was 25.6±12.7 mm and 37.6±11.2 mm, respectively. The radiation was delivered successfully to all patients, with a mean irradiation time of 20.1±61 7 sec. No adverse event including myocardial infarction, death, or stent thrombosis occurred during the follow-up period (mean 10.3±3.7 mon) and non-target vessel revascularization was needed in one patient. Six-month binary angiographic restenosis rate was 10.4% (2 focal ISR and 3 edge restenosis) and loss index was 0.17±0.31. Irradiation using 188 Re-MAG3-filled balloon following rotational atherectomy for patients with diffuse ISR may improve the clinical and angiographic outcomes. Further prospective randomized trials are warranted to evaluate the synergistic effect of debulking and irradiation in patients with diffuse ISR

  19. Drug-eluting stents: from bench-top to clinical research

    NARCIS (Netherlands)

    Basalus, Mounir Welson Zakhary

    2013-01-01

    The development of drug-eluting stents (DES) has improved the invasive treatment of obstructive coronary artery disease by reducing both, restenosis rate and need for reinterventions. This success resulted in a widespread utilization of DES in clinical practice and entailed many clinical research

  20. Stented Vessels: A Challenge for Histological Preparation and Microscopy

    Directory of Open Access Journals (Sweden)

    Andrea Nolte

    2013-06-01

    Full Text Available Objective: The first procedure to treat blocked coronary arteries was coronary artery bypass graft surgery. In 1977, Andreas Gruntzig introduced percutaneous transluminal coronary angioplasty (PTCA. Today, several stent systems exist ranging from bare metal stents to various drug-eluting stents. Unfortunately, our understanding of the arterial reaction to stent implantation is incomplete – primarily due to technical limitations in the histological study of stented vascular tissue. Methods: In our study, we examined different histological preparation methods based on the embedding material methacrylate. The procedure of embedding and sectioning stented porcine arteries was optimized for the specific requirements, like histochemistry, immunohistochemistry or pre-stained fluorescence. Furthermore, we used a microscopical technique described as fluorescence intensity decay shape analysis microscopy (FIDSAM to eliminate auto-fluorescence from fluorescently labeled tissue. Results: The sections were suitable for histochemical and immunohistochemical staining. Additionally, pre-labeled fluorescence in the porcine tissue was not lost by the embedding process. The evaluation of arterial cross sections with FIDSAM technology gave new, very important insights into the examination possibilities of fluorescently labeled tissue. Conclusions: Future studies of the vascular response to a variety of new stent materials will provide important clues to the pathogenesis resulting in restenosis and occlusion of stents. [J Interdiscipl Histopathol 2013; 1(3.000: 104-112

  1. JetStream Rotational and Aspiration Atherectomy in Treating In-Stent Restenosis of the Femoropopliteal Arteries: Results of the JETSTREAM-ISR Feasibility Study.

    Science.gov (United States)

    Shammas, Nicolas W; Shammas, Gail A; Banerjee, Subhash; Popma, Jeffrey J; Mohammad, Atif; Jerin, Michael

    2016-04-01

    To evaluate the outcomes and stent-device interaction of the JetStream atherectomy device in the treatment of in-stent restenosis (ISR) of the femoropopliteal segment. The JetStream XC atherectomy device, a rotational cutter with aspiration capacity, was evaluated in a prospective cohort of 29 patients (mean age 69.9 ± 11.7 years; 11 men) with femoropopliteal ISR in 32 limbs (ClinicalTrials.gov identifier NCT01722877). Lesion length was 17.4 ± 13.1 cm. The primary effectiveness outcome was acute success (≤ 30% residual narrowing with no serious adverse events). The primary safety endpoint was major adverse events. Secondary endpoints included clinically driven target lesion revascularization (TLR) at 6 months and 1 year and loss of stent integrity as assessed by an angiographic core laboratory. Treated length was 19.5 ± 12.9 cm. Acute success was obtained in 29/32 (91%) limbs. Acute device success (atherectomy alone) was 76% (22/29). Adjunctive balloon angioplasty was performed in all cases at a mean pressure of 11.6 ± 3.3 atm. Embolic filter protection was used in 16 (50%) of 32 limbs. Macrodebris was noted in 2 (12%) of 16 filters. Distal embolization requiring treatment occurred in 3/32 (9.4%) limbs (2 with no filter). Other non-procedure-related adverse events were 1 (3%) death (nonvascular) and 1 (3%) case of major bleeding. There were no new stent fractures or deformities (n=24) postatherectomy. Follow-up was completed on 27 patients (29 limbs) at 6 and 12 months. TLR at these time points occurred in 4/29 (14%) and 12/29 (41%) patients. Patency (duplex-derived peak systolic velocity ratio atherectomy using the XC device has favorable acute results in treating femoropopliteal ISR with high procedure success, no device-stent interaction, and favorably low TLR rates. A multicenter trial is needed to confirm these results. © The Author(s) 2016.

  2. Coronary collaterals and risk for restenosis after percutaneous coronary interventions: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Meier Pascal

    2012-06-01

    Full Text Available Abstract Background The benefit of the coronary collateral circulation (natural bypass network on survival is well established. However, data derived from smaller studies indicates that coronary collaterals may increase the risk for restenosis after percutaneous coronary interventions. The purpose of this systematic review and meta-analysis of observational studies was to explore the impact of the collateral circulation on the risk for restenosis. Methods We searched the MEDLINE, EMBASE and ISI Web of Science databases (2001 to 15 July 2011. Random effects models were used to calculate summary risk ratios (RR for restenosis. The primary endpoint was angiographic restenosis > 50%. Results A total of 7 studies enrolling 1,425 subjects were integrated in this analysis. On average across studies, the presence of a good collateralization was predictive for restenosis (risk ratio (RR 1.40 (95% CI 1.09 to 1.80; P = 0.009. This risk ratio was consistent in the subgroup analyses where collateralization was assessed with intracoronary pressure measurements (RR 1.37 (95% CI 1.03 to 1.83; P = 0.038 versus visual assessment (RR 1.41 (95% CI 1.00 to 1.99; P = 0.049. For the subgroup of patients with stable coronary artery disease (CAD, the RR for restenosis with 'good collaterals' was 1.64 (95% CI 1.14 to 2.35 compared to 'poor collaterals' (P = 0.008. For patients with acute myocardial infarction, however, the RR for restenosis with 'good collateralization' was only 1.23 (95% CI 0.89 to 1.69; P = 0.212. Conclusions The risk of restenosis after percutaneous coronary intervention (PCI is increased in patients with good coronary collateralization. Assessment of the coronary collateral circulation before PCI may be useful for risk stratification and for the choice of antiproliferative measures (drug-eluting stent instead bare-metal stent, cilostazol.

  3. Neointimal responses 3 months after 32P β-emitting stent placement

    International Nuclear Information System (INIS)

    Farb, Andrew; Tang, Anita L.; Shroff, Sweta; Sweet, William; Virmani, Renu

    2000-01-01

    Purpose: Studies have shown a potential benefit of brachytherapy in preventing restenosis. However, the effects of intravascular radiation on arterial healing have not been well-established. The purpose of this study was to explore the histologic changes following placement of β-emitting radioactive stents in arteries focusing on intimal responses and endothelialization. Methods and Materials: 3.0-mm β-emitting 32 P stents (6-μCi and 24-μCi) were placed in rabbit iliac arteries with nonradioactive stents serving as controls. Animals were euthanized at 3 months and histologic assessment, morphometry, and analysis of endothelialization were performed. Results: The lumen areas of 24-μCi stents (4.24 ± 0.22 mm 2 , p 2 , p 2 ). The mean lumen percent stenosis was 11.4 ± 3.0% in the 24-μCi stents (p 32 P β-emitting stents reduce neointimal growth, but healing is incomplete with poor endothelialization at 3 months. Longer-term studies with complete arterial healing are needed to determine whether there is sustained neointimal inhibition by stent-delivered brachytherapy

  4. Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)

    2003-08-01

    Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)

  5. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007393.htm Angioplasty and stent placement - peripheral arteries To use the sharing features ... inside the arteries and block blood flow. A stent is a small, metal mesh tube that keeps ...

  6. Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a {sup 188}Re-MAG3-filled balloon: six-month clinical and angiographic results of R4 registry

    Energy Technology Data Exchange (ETDEWEB)

    Moon, D. H.; Oh, S. J.; Park, S. W.; Hong, M. K.; Lee, C. H.; Kim, J. Z.; Park, S. J.; Lee, H. K. [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2000-07-01

    Intracoronary {beta}-irradiation after rotational atherectomy may be a reasonable approach to prevent recurrent in-stent restenosis (ISR). This study was done to evaluate the feasibility and efficacy of {beta}-radiation therapy with a {sup 188}Re-MAG3-filled balloon following rotational atherectomy for ISR. Fifty consecutive patients with diffuse ISR (length >10 mm) in native coronary arteries underwent rotational atherectomy and adjunctive balloon angioplasty followed by {beta}-irradiation using {sup 188}Re-MAG3-filled balloon catheter. The radiation doses was 15 Gy at 1.0 mm deep into vessel wall. Mean length of the lesion and irradiated segment was 25.6{+-}12.7 mm and 37.6{+-}11.2 mm, respectively. The radiation was delivered successfully to all patients, with a mean irradiation time of 20.1{+-}61 7 sec. No adverse event including myocardial infarction, death, or stent thrombosis occurred during the follow-up period (mean 10.3{+-}3.7 mon) and non-target vessel revascularization was needed in one patient. Six-month binary angiographic restenosis rate was 10.4% (2 focal ISR and 3 edge restenosis) and loss index was 0.17{+-}0.31. Irradiation using {sup 188}Re-MAG3-filled balloon following rotational atherectomy for patients with diffuse ISR may improve the clinical and angiographic outcomes. Further prospective randomized trials are warranted to evaluate the synergistic effect of debulking and irradiation in patients with diffuse ISR.

  7. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  8. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study

    Directory of Open Access Journals (Sweden)

    Teeuwen Koen

    2012-12-01

    Full Text Available Abstract Background Percutaneous recanalization of total coronary occlusion (TCO was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST with drug-eluting stents (DES for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New DES with bioresorbable polymer coatings were developed to address these safety concerns. No randomized trials have evaluated the efficacy and safety of the new-generation DES with bioresorbable polymers in patients treated for TCO. Methods/Design The prospective, randomized, single-blinded, multicenter, non-inferiority PRISON IV trial was designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (Orsiro; Biotronik, Berlin, Germany compared with everolimus-eluting stents with durable polymers (Xience Prime/Xpedition; Abbott Vascular, Santa Clara, CA, USA in patients with successfully recanalized TCOs. In total, 330 patients have been randomly allocated to each treatment arm. Patients are eligible with estimated duration of TCO ≥4 weeks with evidence of ischemia in the supply area of the TCO. The primary endpoint is in-segment late luminal loss at 9-month follow-up angiography. Secondary angiographic endpoints include in-stent late luminal loss, minimal luminal diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9-month follow-up. Additionally, optical coherence

  9. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    International Nuclear Information System (INIS)

    Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.

    2011-01-01

    Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  10. Delayed cerebral infarction due to stent folding deformation following carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.

  11. Stent-induced flow disturbances in the ipsilateral external carotid artery following internal carotid artery stenting: a temporary cause of jaw claudication.

    Science.gov (United States)

    Giurgea, Georgiana-Aura; Haumer, Markus; Mlekusch, Irene; Sabeti-Sandor, Schila; Dick, Petra; Schillinger, Martin; Minar, Erich; Mlekusch, Wolfgang

    2017-07-01

    We hypothesize that stenting of the internal carotid artery can immediately impede blood flow to the external carotid artery by either plaque shift or stent coverage of the ostium, and thereby cause ischemic symptoms like ipsilateral jaw claudication. Thirty-three patients with high-grade asymptomatic stenosis of the internal carotid artery who underwent endovascular treatment were examined by ultrasound of the external carotid artery and performed an exercise test by chewing chewing gum synchronously to an electronic metronome for 3 min. Tests were performed before, the day after, and 1 week after the stenting procedure. Claudication time was defined as the timespan until occurrence of pain of the masseter muscle and/or chewing dyssynchrony to the metronome for more than 15 s. Ten patients with an isolated, atherosclerotic stenosis of the external carotid artery served as controls. A significantly reduced claudication time (in seconds) was recorded in patients who underwent carotid artery stenting compared to baseline values; median 89 (interquartile range, IQR, 57 to 124) vs. median 180 (IQR 153 to 180; p external carotid artery into faster or slower as 200 cm/sec, the effect was even accentuated. Stenting values showed improvement 1 week after but did not return to baseline levels. No respective changes were found in controls. Stenting of the internal carotid artery lead to ipsilateral flow deterioration at the external carotid artery resulting in temporary jaw claudication. This impairment attenuated over the time and was significantly reduced after 1 week.

  12. Incidence and classification of neointimal proliferation and in-stent restenosis in post-stenting patients at 1-year interval: Findings from non-invasive coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Nan, E-mail: southmuch@hotmail.com [Department of Radiology, East Hospital, Tongji University School of Medicine, No. 150, Jimo Road, Shanghai 200120 (China); Zhang, Jiayin, E-mail: andrewssmu@msn.com [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Li, Minghua, E-mail: drliminghua@gmail.com [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Pan, Jingwei, E-mail: drpanjingwei@gmail.com [Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Lu, Zhigang, E-mail: drluzhigang@gmail.com [Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China)

    2014-10-15

    Highlights: • The incidence of silent in-stent restenosis at 1-year as revealed by CT is 7.6%. • The incidence of neointimal proliferation at 1-year as revealed by CT is 12.6%. • Diabetes are associated with higher incidence of neointimal proliferation. - Abstract: Objectives: To evaluate the incidence of coronary in-stent restenosis (ISR) and neointimal proliferation by coronary CT angiography (CCTA) at 1-year follow-up in asymptomatic patients. Methods: 234 patients (mean age: 67 ± 10.2 years, range 39–88 years, 180 males and 54 females) with 379 stents were prospectively enrolled in this study. Binary ISR was classified by CCTA into 4 types using Mehran classification. Neointimal proliferation was similarly classified into focal and diffuse types. All patients with CCTA-revealed ISR or neointimal proliferation underwent further invasive coronary angiography (ICA) for validation. Fisher's exact test was used for comparison. Results: ICA revealed patent stents with neointimal proliferation in 39 patients (16.7%, 39/234) and binary ISR in 23 patients (9.8%, 23/234). Lesion-based analysis showed 12 type I ISR lesions, 4 type II ISR lesions, 1 type III ISR lesion and 7 type IV ISR lesions. Among cases with neointimal proliferation, 27 lesions were classified as focal type whereas 13 lesions were classified as diffuse type. Patients with diabetes mellitus were associated with higher incidence of CCTA-revealed neointimal proliferation (21/77 vs. 18/157, p = 0.002) as well as ISR (12/77 vs. 11/157, p = 0.038), compared to patients without diabetes. CCTA was found to have good diagnostic performance for neointimal proliferation and ISR detection as well as classification, with an overall accuracy of 84.4% (54/64). Conclusions: Silent ISR as well as neointimal proliferation is not uncommon findings in asymptomatic post-stenting patients at 1-year interval, as revealed by CCTA. Patients with diabetes are prone to have higher incidence of neointimal

  13. High Residual Collagen-Induced Platelet Reactivity Predicts Development of Restenosis in the Superficial Femoral Artery After Percutaneous Transluminal Angioplasty in Claudicant Patients

    Energy Technology Data Exchange (ETDEWEB)

    Gary, Thomas, E-mail: thomas.gary@medunigraz.at [Medical University of Graz, Division of Angiology, Department of Internal Medicine (Austria); Prüller, Florian, E-mail: florian.prueller@klinikum-graz.at; Raggam, Reinhard, E-mail: reinhard.raggam@klinikum-graz.at [Medical University of Graz, Clinical Institute of Medical and Chemical Laboratory Diagnostics (Austria); Mahla, Elisabeth, E-mail: elisabeth.mahla@medunigraz.at [Medical University of Graz, Department of Anesthesiology and Intensive Care Medicine (Austria); Eller, Philipp, E-mail: philipp.eller@medunigraz.at; Hafner, Franz, E-mail: franz.hafner@klinikum-graz.at; Brodmann, Marianne, E-mail: marianne.brodmann@medunigraz.at [Medical University of Graz, Division of Angiology, Department of Internal Medicine (Austria)

    2016-02-15

    PurposeAlthough platelet reactivity is routinely inhibited with aspirin after percutaneous angioplasty (PTA) in peripheral arteries, the restenosis rate in the superficial femoral artery (SFA) is high. Interaction of activated platelets and the endothelium in the region of intervention could be one reason for this as collagen in the subendothelium activates platelets.Materials and MethodsA prospective study evaluating on-site platelet reactivity during PTA and its influence on the development of restenosis with a total of 30 patients scheduled for PTA of the SFA. Arterial blood was taken from the PTA site after SFA; platelet function was evaluated with light transmission aggregometry. After 3, 6, 12, and 24 months, duplex sonography was performed and the restenosis rate evaluated.ResultsEight out of 30 patients developed a hemodynamically relevant restenosis (>50 % lumen narrowing) in the PTA region during the 24-month follow-up period. High residual collagen-induced platelet reactivity defined as AUC >30 was a significant predictor for the development of restenosis [adjusted odds ratio 11.8 (9.4, 14.2); P = .04].ConclusionsHigh residual collagen-induced platelet reactivity at the interventional site predicts development of restenosis after PTA of the SFA. Platelet function testing may be useful for identifying patients at risk.

  14. Timing of silicone stent removal in patients with post-tuberculosis bronchial stenosis.

    Science.gov (United States)

    Eom, Jung Seop; Kim, Hojoong; Park, Hye Yun; Jeon, Kyeongman; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung

    2013-10-01

    In patients with post-tuberculosis bronchial stenosis (PTBS), the severity of bronchial stenosis affects the restenosis rate after the silicone stent is removed. In PTBS patients with incomplete bronchial obstruction, who had a favorable prognosis, the timing of stent removal to ensure airway patency is not clear. We evaluated the time for silicone stent removal in patients with incomplete PTBS. A retrospective study examined PTBS patients who underwent stenting and removal of a silicone stent. Incomplete bronchial stenosis was defined as PTBS other than total bronchial obstruction, which had a luminal opening at the stenotic segment on bronchoscopic intervention. The duration of stenting was defined as the interval from stent insertion to removal. The study included 44 PTBS patients and the patients were grouped at intervals of 6 months according to the duration of stenting. Patients stented for more than 12 months had a significantly lower restenosis rate than those stented for less than 12 months (4% vs. 35%, P = 0.009). Multiple logistic regression revealed an association between stenting for more than 12 months and a low restenosis rate (odds ratio 12.095; 95% confidence interval 1.097-133.377). Moreover, no restenosis was observed in PTBS patients when the stent was placed more than 14 months previously. In patients with incomplete PTBS, stent placement for longer than 12 months reduced restenosis after stent removal.

  15. Progress in the study of drug-eluting intra-stent thrombosis

    International Nuclear Information System (INIS)

    Guo Zhifu; Zheng Xing; Qin Yongwen

    2007-01-01

    Durg-eluting stent has been regarded as the milestone in the history of PCI for their efficiency in the prevention of coronary arterial restenosis after percutaneous coronary intervention. But unfortunately intra-stent thrombosis continues to be a serious complication of contemporary DES use. The incidence of drug-eluting stents thrombosis is at least not lower than that of bare metal stents at present. The clinical consequences of stent thrombosis are frequently catastrophic, including death in 40% to 50% of the cases or major myocardial infarction in 60% to 70%. Premature discontinuation of standard antiplatelet therapy is by far the most important predictor of stent thrombosis with DES and other predictors included renal failure, diabetes, bifurcation lesions, multiple lesions or multivessel disease, long stents, female, advanced age, stent underexpansion and residual stenosis etc. The delayed endothelialization may be the underling mechanism of DES thrombosis. (authors)

  16. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  17. Usefulness of Eosinophil-Lymphocyte Ratio to Predict Stent Restenosis

    Directory of Open Access Journals (Sweden)

    Mehmet Zihni Bilik

    2016-06-01

    Full Text Available Objective: Stent restenosis (SR is an important compli­cation of percutaneous coronary intervention. There are many studies explored the relation of eosinophils with SR, however, there is no data about relationship between eo­sinophil-lymphocyte ratio (ELR and SR. In this study we aimed to investigate the relationship between the value of ELR on admission and SR. Methods: The study was included 314 patients who had been applied a coronary stent implantation and they were admitted to cardiology clinic with stabile angina and un­derwent repeat coronary angiography. The data obtained from patients were analyzed retrospectively. The patient group was consisted of 197 patients who were diagnosed as SR, and the control group was consisted of 117 pa­tients whose stents were patent angiographically. Results: The groups were similar in terms of age, gender, hypertension, diabetes mellitus, LDL-C, HDL-C, platelet count, platelet-lymphocyte ratio (PLR, hemoglobin and left ventricle ejection fraction (LVEF. White blood cell (WBC, neutrophil, eosinophil, C-reactive protein (CRP, ELR and neutrophil-lymphocyte ratio (NLR on admission were higher in the SR group compared to the controls. All patients were categorized into two groups according to ELR values and SR was more frequent in the high ELR group compared to low ELR group. An ELR value of ≥0.745 predicted SR with 64% sensitivity and 61% specif­ity. Conclusion: In this study ELR was found statistically higher in SR patients compared to the controls. Accord­ing to our data ELR as an inexpensive and easy method, may contribute to determination of high risk patients and increased ELR can be used as a predictor of SR.

  18. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  19. COVERED STENTS IN IATROGENIC CORONARY ARTERY FISTULA; A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Masoud Poormoghaddas

    2010-11-01

    Full Text Available Abstract    BACKGROUND: Coronary artery fistula is an abnormal communication between a coronary artery and a cardiac chamber or major cardiac vessels, mostly congenital but some of them are acquired as a consequence of coronary artery perforation.    CASE PRESENTATION: We report a case of cavity spilling coronary artery perforation during percutaneous coronary intervention 7 years ago. Because of continuing symptoms and risk of developing heart failure and pulmonary hypertension we were ought to treat this iatrogenically formed coronary artery fistula. We used stent graft implantation to treat it with acceptable results.    CONCLUSION: Beside their application as a rescue for acute coronary artery perforations, stent grafts can be used with acceptable results in iatrogenically acquired coronary artery coronary artery fistula      Keywords: Coronary artery perforation, Coronary artery fistula, Stent graft.

  20. Long-Term Results after Placement of Aortic Bifurcation Self-Expanding Stents: 10 Year Mortality, Stent Restenosis, and Distal Disease Progression

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Bhat, Raj; Ross, Rose; Stonebridge, Peter A.

    2007-01-01

    Purpose. To retrospectively evaluate the 10 year follow-up results in patients who had 'kissing' self-expanding stent aortic bifurcation reconstruction. Methods. Forty-three patients were treated with 'kissing' self-expanding stents for aortoiliac occlusive disease. Early follow-up with clinical and ankle brachial pressure indices (ABPI) was performed at 3, 6, 12, and 24 months and with intra-arterial digital subtraction angiography at 12-24 months; clinical and angiographic follow-up was performed for symptom recurrence up to 10 years after treatment. Retrospective record review was performed to assess mortality, clinical patency, angiographic patency, and secondary assisted patency of both stents and downstream peripheral vessels at 5 and 10 years follow-up. Results. The 2 year primary angiographic and secondary assisted stent patencies were 89% and 93%, respectively. At 10 years follow-up in 40 patients the mortality was 38% (due to myocardial infarction, stroke, chronic renal failure, malignancy, and liver failure). At 5 and 10 years follow-up the primary clinical stent patency was 82% and 68%, and the secondary assisted stent patency 93% and 86%, respectively. At 5 and 10 years, the distal vessel patency was 86% and 72%, and the secondary assisted distal vessel patency treated by surgical or endovascular techniques was 94% and 88%, respectively. At 10 years there was no limb loss. Conclusion. The long-term (10 year) results of aortic bifurcation arterial self-expanding stent placement in patients with arterial occlusive disease show a 10 year primary stent patency rate of 68% but a secondary assisted patency rate of 86%. In addition there is a high overall mortality due to other cardiovascular causes and the rate of distal disease progression and loss of patency is similar to the loss of stent patency rate

  1. Temporary stenting and retrieval of the self-expandable, intracranial stent in acute middle cerebral artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Sang Hyun; Chung, Tae-Sub [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea); Lee, Kyung-Yul [Yonsei University College of Medicine, Department of Neurology, Gangnam Severance Hospital, Seoul (Korea); Hong, Chang Ki; Kim, Chang-Hyun [Yonsei University College of Medicine, Department of Neurosurgery, Gangnam Severance Hospital, Seoul (Korea); Kim, Byung Moon; Kim, Dong Ik [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea)

    2009-08-15

    We describe our experience in which a retrievable Enterprise stent was used as a temporary recanalization and embolectomy device in an acute middle cerebral artery (MCA) occlusion after urgent stenting for ipsilateral carotid artery stenosis. (orig.)

  2. Timing of silicone stent removal in patients with post-tuberculosis bronchial stenosis

    Directory of Open Access Journals (Sweden)

    Jung Seop Eom

    2013-01-01

    Full Text Available Context: In patients with post-tuberculosis bronchial stenosis (PTBS, the severity of bronchial stenosis affects the restenosis rate after the silicone stent is removed. In PTBS patients with incomplete bronchial obstruction, who had a favorable prognosis, the timing of stent removal to ensure airway patency is not clear. Aims: We evaluated the time for silicone stent removal in patients with incomplete PTBS. Settings and Design: A retrospective study examined PTBS patients who underwent stenting and removal of a silicone stent. Methods: Incomplete bronchial stenosis was defined as PTBS other than total bronchial obstruction, which had a luminal opening at the stenotic segment on bronchoscopic intervention. The duration of stenting was defined as the interval from stent insertion to removal. The study included 44 PTBS patients and the patients were grouped at intervals of 6 months according to the duration of stenting. Results: Patients stented for more than 12 months had a significantly lower restenosis rate than those stented for less than 12 months (4% vs. 35%, P = 0.009. Multiple logistic regression revealed an association between stenting for more than 12 months and a low restenosis rate (odds ratio 12.095; 95% confidence interval 1.097-133.377. Moreover, no restenosis was observed in PTBS patients when the stent was placed more than 14 months previously. Conclusions: In patients with incomplete PTBS, stent placement for longer than 12 months reduced restenosis after stent removal.

  3. Low-profile stent placement with the monorail technique for treatment of renal artery stenosis: midterm results of a prospective trial.

    Science.gov (United States)

    Müller-Hülsbeck, Stefan; Frahm, Christian; Behm, Charlotte; Schäfer, Phillip Jobst; Bolte, Hendrik; Heller, Martin; Jahnke, Thomas

    2005-07-01

    To determine feasibility, safety, and midterm patency of a monorail balloon stent device for the treatment of renal artery stenosis (RAS). During a period of 30 months, 47 patients (with severe hypertension, n=45; renal insufficiency, n=20) with 50 cases of RAS and indications for stent implantation (calcified ostial lesion, n=41; insufficient percutaneous transluminal angioplasty, n=6; dissection, n=3) were enrolled into the prospective evaluation. After predilation, 59 stents (Rx-Herculink 4 mm, n=2; 5 mm, n=19; 6 mm, n=35; 7 mm, n=3) were implanted under manometer control with use of the long-sheath technique (5 F; 6 F for 7-mm stents) via a femoral (n=44) or transbrachial approach (n=6). Parameters of hypertension and renal insufficiency were determined before and after the procedure and for a maximum of 18 months. Restenosis rate was determined with color duplex ultrasonography. Renal artery stent placement (mean diameter, 5.7 mm; mean length, 16 mm) was technically successful in all cases (100%). Mean blood pressure and serum creatinine level decreased from 177/93 mm Hg to 145/78 mm Hg and from 1.8 mg/dL to 1.5 mg/dL, respectively. Within 48 hours after the implantation, acute occlusions occurred in two patients, supposedly triggered by cholesterol embolization. Primary and primary assisted patency rates were 87% and 92% at 6 months and 75% and 84% at 18 months. Renal artery stent placement with the rapid-exchange monorail system is a safe procedure with promising patency rates. In combination with the long-sheath technique, adequate control of stent deployment is guaranteed during the entire intervention. The low profile of the device facilitates the use of small sheaths (5 F) to minimize access-site complications.

  4. Intracranial Stent Implantation for Drug Resistant Atherosclerotic Stenosis: Results of 52 Cases

    International Nuclear Information System (INIS)

    Kim, Kuk Seon; Hwang, Dae Hyun; Ko, Young Hwan; Kang, Ik Won; Lee, Eil Seong; Han, You Mie; Kim, In Soo; Hur, Choon Woong

    2011-01-01

    We evaluated the usefulness of intracranial stent implantation for treatment of drug resistant atherosclerotic stenoses. Between March 2004 and July 2007, we tried intracranial stent implantation in 49 patients with 52 lesions (anterior circulation 48 cases, posterior circulation 4 cases) who had an ischemic stroke with more than 50% of major cerebral artery stenosis. We classified the lesions by their location and morphology, analyzed the results in terms of the success rate, complication rate, and restenosis rate during the follow-up period. Intracranial stent implantation was performed successfully in 43 cases (82.7%). In eight of the nine cases, the stent implantation failure was due to the tortuosity of the target vessel. There was no major periprocedural complication. One patient showed cerebellar infarction after the procedure. Mean residual stenoses decreased from 70.2% to 13.0%. Four cases (9.3%) demonstrated in-stent restenoses and more than 50% during the mean and 25.3/month after the follow-up period. Success rate of intracranial stent implantation may improve on developing technique and more experience. Low rate of complication and restenosis suggest that we can consider intracranial stent implantation for treatment of drug resistant atherosclerotic stenoses.

  5. Doppler Ultrasonography in Suspected Subclavian Artery Obstruction and in Patient Monitoring after Subclavian Stenting

    International Nuclear Information System (INIS)

    Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Pieniazek, Piotr; Musialek, Piotr; Kozanecki, Artur; Stopa, Ireneusz; Zalewski, Jaroslaw; Tracz, Wieslawa

    2007-01-01

    Purpose. Subclavian or innominate artery (SIA) stenosis affects up to 5% of patients referred to coronary bypass grafting; it is symptomatic in less than half of these. This study aimed to assess the Doppler ultrasonography (DU) findings in SIA obstruction and patients' follow-up after percutaneous angioplasty (PTA). Methods. The study enrolled 118 patients (68 men, 50 women), aged 61.3 ± 8.7 years, with suspected SIA obstruction, in whom peak systolic velocity (PSV) in the SIA and subclavian steal grade were assessed on DU and verified by quantitative angiography (QA). Serial follow-up DU was performed in patients treated with PTA. Results. Grade I-III of subclavian steal from the vertebral artery (VA) was found in 89.8% of patients. In the remaining 10.2% only a PSV increase in the SIA was observed. QA confirmed the presence of SIA obstruction in all patients (stenosis grade: 80.9 ± 17.3%). In patients with one-sided SIA obstruction, the ultrasonographic steal grade correlated with the QA stenosis grade (p < 0.001, r = 0.648). Lack of subclavian steal was noted in the case of distal subclavian stenosis, VA obstruction, VA originating from the aortic arch, and bilateral SIA obstruction. Successful PTA was performed in 77 of 83 patients referred to that procedure. PSV was reduced from 4.4 ± 1.2 (2.2-6.5) m/sec to 1.34 ± 0.51 (0.5-2.5) m/sec and flow in the VA was normalized. During the mean follow-up time of 24.7 ± 15.6 months, there was a gradual increase in the in-stent PSV as well as gradual VA flow alterations, resulting in symptom recurrence. More than a twofold PSV increase, compared with the post-PTA values, was an indicator of restenosis in 11 of 12 patients. Conclusions. Careful DU evaluation enables the recognition of SIA obstruction in all patients. Ninety percent of them have subclavian steal correlating with the stenosis grade. Restenosis can be reliably detected with DU based on in-stent PSV and VA flow alterations

  6. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    International Nuclear Information System (INIS)

    Katsanos, Konstantinos; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris

    2013-01-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 ± 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 ± 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 ± 9.1 %, lesion binary restenosis rate was 64.1 ± 8.3 %, and repeat intervention-free survival was 93.6 ± 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications

  7. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [School of Medicine, Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

  8. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    International Nuclear Information System (INIS)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis; Padayachee, Soundrie; Karunanithy, Narayan; Ahmed, Irfan; Zayed, Hany; Katsanos, Konstantinos

    2015-01-01

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery

  9. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Padayachee, Soundrie [King’s Health Partners, Department of Ultrasonic Angiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Karunanithy, Narayan; Ahmed, Irfan [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Zayed, Hany [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.

  10. Development of a dynamic in vitro model of a stented blood vessel to evaluate the effects of stent strut material selection and surface coating on smooth muscle cell response

    Science.gov (United States)

    Winn, Bradley Huegh

    formation of this new tissue, primarily consisting of VSMCs of the synthetic phenotype and their subsequent extracellular matrix, is the sole causation of in-stent restenosis since the stent serves to prevent elastic recoil and negative remodeling. This doctoral research program is focused on endovascular stent biomaterials science and engineering. Overall, this doctoral project is founded on the hypothesis that smooth muscle cell hyperplasia, as an important causative factor for vascular restenosis following endovascular stent deployment, is triggered by the various effects of stent strut contact on the vessel wall including contact forces and material biocompatibility. In this program, a dynamic in vitro model of a stented blood vessel aimed at evaluating the effect of stent strut material selection, and surface coating on smooth muscle cell response was developed. The in vitro stented artery model was validated through the proliferation of VSMC in contact with stent struts. Additionally, it was demonstrated that, with respect to known biocompatible materials such as Nitinol and 316L stainless steel, DNA synthesis and alpha-actin expression, as indicators of VSMC phenotype, are independent of stent material composition. Furthermore, hydroxyapatite was shown to be a biocompatible stent surface coating with acceptable post-strain integrity. This coating was shown in a feasibility study to be capable of serving as a favorable drug delivery platform able to reliably deliver locally therapeutic doses of bisphosphonates, such as alendronate, to control VSMC proliferation in an in vitro model of a stented blood vessel. This stent coating/drug combination may be effective for reducing restenosis as a result of VSMC hyperplasia in vivo.

  11. Stent Design Affects Femoropopliteal Artery Deformation.

    Science.gov (United States)

    MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey

    2018-03-23

    Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.

  12. Local delivery of sirolimus nanoparticles for the treatment of in-stent restenosis.

    Science.gov (United States)

    Zago, Alexandre C; Raudales, José C; Attizzani, Guilherme; Matte, Bruno S; Yamamoto, German I; Balvedi, Julise A; Nascimento, Ludmila; Kosachenco, Beatriz G; Centeno, Paulo R; Zago, Alcides J

    2013-02-01

    To test the local delivery of sirolimus nanoparticles following percutaneous transluminal coronary angioplasty (PTCA) to treat in-stent restenosis (ISR) in a swine model. Coronary bare-metal stent (BMS) implantation reduces major adverse cardiac events when compared with PTCA; however, ISR rates remain high. Eighteen swine underwent BMS deployment guided by intravascular ultrasound (IVUS). Of these, 16 developed ISR (1 stent/swine) and underwent angioplasty with a noncompliant balloon (PTCA-NC). The animals were then randomized into four groups for local infusion of sirolimus nanoparticles through a porous balloon catheter, as follows: (1) PTCA-NC alone (control); (2) PTCA-NC + (polylactic acid)-based nanoparticle formulation (anionic 1); (3) PTCA-NC + (polylactic-co-glycolic acid)-based nanoparticle formulation (anionic 2); and (4) PTCA-NC + Eudragit RS nanoparticle formulation (cationic). Coronary angiography and IVUS follow-up were performed 28 days after ISR treatment. There was one episode of acute coronary occlusion with the cationic formulation. Late area loss was similar in all groups at 28 days according to IVUS. However, luminal volume loss (control = 20.7%, anionic 1 = 4.0%, anionic 2 = 6.7%, cationic = 9.6%; P = 0.01) and neointimal volume gain (control = 68.7%, anionic 1 = 17.4%, anionic 2 = 29.5%, cationic = 31.2%; P = 0.019) were significantly reduced in all treatment groups, especially in anionic 1. PTCA-NC followed by local infusion of sirolimus nanoparticles was safe and efficacious to reduce neointima in this model, and this strategy may be a promising treatment for BMS ISR. Further studies are required to validate this method in humans. Copyright © 2012 Wiley Periodicals, Inc.

  13. MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen

    International Nuclear Information System (INIS)

    Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.

    2005-01-01

    Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)

  14. Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry

    International Nuclear Information System (INIS)

    Moscarella, Elisabetta; Varricchio, Attilio; Stabile, Eugenio; Franzone, Anna; Granata, Francesco; Rapacciuolo, Antonio; Galasso, Gennaro; Capozzolo, Claudia; Cirillo, Plinio

    2015-01-01

    Background/purpose: Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. Methods/materials: Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months. Results: A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6 ± 15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%). Conclusions: Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial. - Highlights: • A safe therapeutic option for the treatment of diffuse ISR; • Technically feasible; • Associated to a low rate of restenosis recurrence at nine month.

  15. Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry

    Energy Technology Data Exchange (ETDEWEB)

    Moscarella, Elisabetta [Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi (Italy); Varricchio, Attilio [Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, Napoli (Italy); Stabile, Eugenio, E-mail: geko50@hotmail.com [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Franzone, Anna [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Granata, Francesco [Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi (Italy); Rapacciuolo, Antonio; Galasso, Gennaro [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Capozzolo, Claudia [Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, Napoli (Italy); Cirillo, Plinio [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); and others

    2015-10-15

    Background/purpose: Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. Methods/materials: Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months. Results: A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6 ± 15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%). Conclusions: Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial. - Highlights: • A safe therapeutic option for the treatment of diffuse ISR; • Technically feasible; • Associated to a low rate of restenosis recurrence at nine month.

  16. Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?

    Science.gov (United States)

    Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi

    2010-06-01

    The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.

  17. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  18. [Effect of nattokinase on restenosis after percutaneous transluminal angioplasty of the abdominal artery in rabbits].

    Science.gov (United States)

    Gong, Min; Lin, Huan-bing; Wang, Qian; Xu, Jiang-ping

    2008-08-01

    To investigate the effect of nattokinase on intimal hyperplasia in rabbit abdominal artery after balloon injury and explore a novel strategy for the preventing restenosis after percutaneous transluminal angioplasty. Fifty-six New Zealand rabbits were randomly divided into 7 groups, namely the solvent control group, model group, natto extract lavage group, refined nattokinse lavage group, intravenous refined nattokinse injection group, clopidogrel group and clopidogrel-aspirin group. Balloon injury was induced by inserting the catheter through the femoral artery into the thoracic aorta of the rabbits. The platelet counts were notad and platelet aggregation was observed, and the abdominal artery was taken for pathological analysis. The expressions of MMP-2 and -9 in the abdominal artery were detected immunohistochemically. There was no significant difference in the platelet counts, platelet aggregation rate or MMP-2 and -9 expression between the model group and the nattokinse-treated groups (P>0.05). The stenosis index in each nattokinse-treated group was significantly greater and the neointimal proliferation index smaller than that of the model group (P<0.01 or 0.05). Nattokinse can inhibit restenosis of rabbit abdominal artery after percutaneous transluminal angioplasty, which is independent of its actions on the platelet or MMP-2 and -9 expressions.

  19. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  20. Flow Velocities After Carotid Artery Stenting: Impact of Stent Design. A Fluid Dynamics Study in a Carotid Artery Model with Laser Doppler Anemometry

    International Nuclear Information System (INIS)

    Greil, Oliver; Kleinschmidt, Thomas; Weiss, Wolfgang; Wolf, Oliver; Heider, Peter; Schaffner, Silvio; Gianotti, Marc; Schmid, Thomas; Liepsch, Dieter; Berger, Hermann

    2005-01-01

    Purpose. To study the influence of a newly developed membrane stent design on flow patterns in a physiologic carotid artery model. Methods. Three different stents were positioned in silicone models of the carotid artery: a stainless steel stent (Wall-stent), a nitinol stent (SelfX), and a nitinol stent with a semipermeable membrane (MembraX). To increase the contact area of the membrane with the vessel wall, another MembranX model was modified at the outflow tract. The membrane consists of a biocompatible silicone-polyurethane copolymer (Elast-Eon) with a pore size of 100 μm. All stents were deployed across the bifurcation and the external carotid artery origin. Flow velocity measurements were performed with laser Doppler anemometry (LDA), using pulsatile flow conditions (Re = 220; flow 0.39 l/min; flow rate ratio ICA:ECA = 70:30) in hemodynamically relevant cross-sections. The hemodynamic changes were analyzed by comparing velocity fluctuations of corresponding flow profiles. Results. The flow rate ratio ICA:ECA shifted significantly from 70/30 to 73.9/26.1 in the MembraX and remained nearly unchanged in the SelfX and Wallstent. There were no changes in the flow patterns at the inflow proximal to the stents. In the stent no relevant changes were found in the SelfX. In the Wallstent the separation zone shifted from the orifice of the ICA to the distal end of the stent. Four millimeters distal to the SelfX and the Wallstent the flow profile returned to normal. In the MembraX an increase in the central slipstreams was found with creation of a flow separation distal to the stent. With a modification of the membrane this flow separation vanished. In the ECA flow disturbances were seen at the inner wall distal to the stent struts in the SelfX and the Wallstent. With the MembraX a calming of flow could be observed in the ECA with a slight loss of flow volume. Conclusions. Stent placement across the carotid artery bifurcation induces alterations of the physiologic flow

  1. 53. Bilateral ductal stenting for nonconfluent pulmonary arteries in a newborn

    Directory of Open Access Journals (Sweden)

    K. Al Dhahri

    2016-07-01

    Full Text Available Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Limited data available for bilateral PDA stenting. Bilateral PDA stenting in nonconfluent pulmonary arteries is challenging procedure but can be considered as an option in the management of complex conditions like this. 12 days old Preterm (36 weeks gestation male baby with birth weight of 2.6 kg developed respiratory distress with severe cyanosis and desaturation upto 50%. Baby was intubated and started on Prostaglandin 0.05 mic/kg/mt. His saturation improved to 80%. Echocardiogram showed complex cyanotic heart disease, Situs ambiguous, dextrocardia, complete unbalanced AV septal defect, pulmonary atresia , nonconfluent small branch pulmonary arteries supplied by the bilateral patent ductus arteriosus (PDA from right aortic arch and all four pulmonary veins form a confluence and drain into superior vena cava(SVC through vertical vein with no obstruction. Baby was taken up for PDA stenting. descending aortogram showed right aortic arch with vertical tortuous duct to right pulmonary artery (RPA and another short duct with acute angle from left subclavian artery to left pulmonary artery (LPA . Both ducti stented with coronary stents. Vertical vein angiogram showed both lungs drain to a confluence and then to SVC via ascending vertical vein with no obstruction. After stenting lung perfusion improved and the baby was stable and maintained 80% saturation on room air. Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Our case is unique with Heterotaxy, TAPVC, Dextrocardia and double ducti. Eventhough bilateral ductal stenting is technically challenging it is successful through femoral artery approach.

  2. Emergency interventional therapy of peripheral arterial stenosis and thrombosis

    International Nuclear Information System (INIS)

    Cai Fengquan; Yu Xixiang

    2004-01-01

    Objective: To evaluate the clinical value of emergency interventional therapy of stenosis and thrombosis of peripheral arteries. Methods: 26 patients suffered from stenosis and thrombosis of peripheral arteries including, 3 subclavical arteries, 5 iliac arteries, 7 femoral arteries, 4 popliteal arteries, 4 posterior or anterior tibial arteries, 2 graft vessels and 1 instent restenosis were undertaken interventional ATD or urokinase infusion thrombolysis, percutanous transluminal angioplasty (PTA) and stent placement. Results: The stenotic arteries were recanalized after PTA or stent placement and the thrombosis vanished after thrombolysis with distal flowes improved or resumed. Clinical symptom was ameliorated. No more complication occurred except one patient with alimentary hemorrhage after thrombolysis. The patients were followed up from 1 to 20 months with all the involved arteries keeping in constant patency without any amputation. Conclusions: Emergency thrombolysis by machine or drug along with PTA or stent placement can effectively cure the stenosis or thrombosis of peripheral artery with recanalization and no amputation. (authors)

  3. Brachytherapy on restenosis. 32P radioisotope in animal model

    International Nuclear Information System (INIS)

    Bergoc, R.; Rivera, E.; Cocca, C.; Martin, G.; Cricco, G.; Croci, M.; Guzman, L.

    2000-01-01

    Despite a notorious decline in age-adjusted death rates for cardiovascular pathologies, coronary artery disease still remains as the main cause of mortality above the age of 40 in men and 60 in women. More than 25% of death in persons over the age of 35 are due to coronary disease. In about 50% of men and 30% of women, the first manifestation of the disease is an acute myocardial infarction and 10% a sudden cardiac death. In Argentina it is estimated that in 1998 about 100.000-115.000 people suffered as first manifestation of coronary illness a myocardial acute infarct. Angioplasty has an important and well established site in the treatment of the coronary illness and restenosis represents the principal complication of this method for myocardial re-vascularization. About a 35-40% of treated arteries present restenosis within the first six month the intervention with the concomitant need of re-interventions, re-hospitalizations, by-pass surgery, work discontinuity and the high cost for the health system. A number of drugs were tested as anti-restenosis: anticoagulants, aspirin, antispasmodics and lipid-lowering agents but none was clearly efficient; also, experimental studies in which intravascular irradiation with different source types and energies, radiation doses and doses rate to prevent restenosis was utilized; however, there is no consensus in many aspects of this intravascular brachytherapy. The first step in this work was to induce the experimental model in rabbits. Afterwards, by means of the balloon methodology and stent implantation, brachytherapy experiments were carried out to evaluate the biological effect on different layers of arteries, with different Doses using a beta particle emitting radioisotope ( 32 P). The arteriosclerotic lesions were induced in New Zealand rabbits through the administration of a diet with high cholesterol content. Angioplastic interventions on femoral arteries were done with balloon methodology and controlled by fluoroscopy

  4. Coronary Stents: The Impact of Technological Advances on Clinical Outcomes.

    Science.gov (United States)

    Mennuni, Marco G; Pagnotta, Paolo A; Stefanini, Giulio G

    2016-02-01

    Percutaneous coronary interventions (PCI) were proposed in the late 1970s as an alternative to surgical coronary artery bypass grafting for the treatment of coronary artery disease. Important technological progress has been made since. Balloon angioplasty was replaced by bare metal stents, which allowed to permanently scaffold the coronary vessel avoiding acute recoil and abrupt occlusion. Thereafter, the introduction of early generation drug-eluting stents (DES) has significantly improved clinical outcomes, primarily by markedly reducing the risk of restenosis. New generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new limus antiproliferative agents, have further improved upon the safety and efficacy profile of early generation DES. The present article aims to review the impact of technological advances on clinical outcomes in the field of PCI with coronary stents, and to provide a brief overview on clinical margins of improvement and unmet needs of available DES.

  5. Primary stenting as emergency therapy in acute basilar artery occlusion

    International Nuclear Information System (INIS)

    Spreer, Joachim; Arnold, Sebastian; Klisch, Joachim; Schumacher, Martin; Els, Thomas; Hetzel, Andreas; Huppertz, Hans-Juergen; Oehm, Eckhardt

    2002-01-01

    In three patients with acute occlusion of the basilar artery intra-arterial fibrinolysis resulted in only partial recanalization and revealed severe stenosis as the underlying cause. Application of micro-stents without previous dilatation resulted in vessel re-opening. Two patients had an excellent clinical outcome. One patient died 10 days after the stroke due to brainstem infarction. Emergency primary stent application may improve the outcome in acute basilar artery occlusion, if intra-arterial thrombolysis fails to re-establish a sufficient flow. (orig.)

  6. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation

    International Nuclear Information System (INIS)

    Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman; Wichter, Thomas; Grude, Matthias

    2003-01-01

    The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)

  7. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

    Science.gov (United States)

    Holzapfel, Gerhard A; Stadler, Michael; Gasser, Thomas C

    2005-02-01

    Clinical studies have identified factors such as the stent design and the deployment technique that are one cause for the success or failure of angioplasty treatments. In addition, the success rate may also depend on the stenosis type. Hence, for a particular stenotic artery, the optimal intervention can only be identified by studying the influence of factors such as stent type, strut thickness, geometry of the stent cell, and stent-artery radial mismatch with the wall. We propose a methodology that allows a set of stent parameters to be varied, with the aim of evaluating the difference in the mechanical environment within the wall before and after angioplasty with stenting. Novel scalar quantities attempt to characterize the wall changes inform of the contact pressure caused by the stent struts, and the stresses within the individual components of the wall caused by the stent. These quantities are derived numerically and serve as indicators, which allow the determination of the correct size and type of the stent for each individual stenosis. In addition, the luminal change due to angioplasty may be computed as well. The methodology is demonstrated by using a full three-dimensional geometrical model of a postmortem specimen of a human iliac artery with a stenosis using imaging data. To describe the material behavior of the artery, we considered mechanical data of eight different vascular tissues, which formed the stenosis. The constitutive models for the tissue components capture the typical anisotropic, nonlinear and dissipative characteristics under supra-physiological loading conditions. Three-dimensional stent models were parametrized in such a way as to enable new designs to be generated simply with regard to variations in their geometric structure. For the three-dimensional stent-artery interaction we use a contact algorithm based on smooth contact surfaces of at least C-continuity, which prevents numerical problems known from standard facet-based contact

  8. Application of the Enterprise Stent in Atherosclerotic Intracranial Arterial Stenosis: A Series of 60 Cases.

    Science.gov (United States)

    Wang, Xiaofei; Wang, Zhigang; Wang, Chengwei; Ji, Yong; Ding, Xuan; Zang, Yizheng

    2016-01-01

    We assessed the safety and effectiveness of the Enterprise stent in treating atherosclerotic intracranial arterial stenosis (AIAS). This was a retrospective study conducted with 60 consecutive patients with 62 AIAS lesions who received the Enterprise stent at the Department of Neurosurgery, Second Hospital of Shandong University between June 2012 and January 2014. All patients were assessed using the modified Rankin scoring system at discharge. Clinical follow-ups and digital subtraction angiography (DSA) were performed at 1, 3, 6 and 12 months postoperatively. There were 42 men and 18 women with a mean age of 56.8 ± 8.0 years. Fourteen lesions (22.6%) were at the anterior and 48 (77.4 %) were at the posterior circulation. The mean stenosis rate was 76.3 ± 12.7%. The mean stenotic vessel length was 7.7 ± 2.0 mm. The technical success rate was 100%. The mean post-stent residual stenosis rate was 22.8 ± 4.8%. Five patients (8.3%) had perioperative complications, but no disability or mortality occurred within 30 days. The mean follow-up duration was 6.2 months. DSA was used to evaluate 45 lesions (72.6%) six months postoperatively: 6 (13.3%) had postoperative restenoses, 2 at the anterior circulation, and 4 at the posterior circulation. Of these 6, 4 (66.7%) were immediate residual stenoses after stenting. The residual stenosis rate was identified as a risk factor for restenosis. Five (8.3%) ischemic events, consistent with the vascular lesions, occurred. Application of the Enterprise stent was safe and efficacious. The technical success rate was high while the perioperative complication rate was low.

  9. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France); Hopital Gui de Chauliac, Department of Neurology, Service de Neurologie, Montpellier, Cedex 5 (France); Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain [Hopital Gui de Chauliac, Department of Neuroradiology, CHU Montpellier, Montpellier, Cedex 5 (France); Thouvenot, Eric [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-02-15

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS {<=}1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  10. Metallic stent for the treatment of iliac arterial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Chung, Jin Wook; Han, Joon Koo; Suh, Chul Soo; Yoo, Jae Wook; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of); Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of)

    1993-07-15

    In order to study the clinical efficacy of the metallic stent of the treatment of iliac arterial stenosis, the clinical and arteriographic findings of the 8 patients were retrospectively reviewed. All 8 patients were males with an age of 51 to 79. The Fontaine class for the functional status of lower extremities was II in 4 patients, III in 3 patents and IV in 1 patient. Self expandable Gianturco stent was inserted of in 7 iliac arteries and balloon expandable Palmaz stent was inserted in 2 iliac arteries in the 8 patients. The indications for the metallic stent application were localized dissection with significant residual stenosis in 6 sites, recoiling due to calcification in one case and eccentricity of the stenosislesionin 2 sites. The deployment of the metallic stent was successful in all the cases to maintain the patency of iliac arteries with residual stenosis less than 30%. The Fontaine class was improved to 1 in 6 patients, IIa in 1 patient and IIb in another one. During the follow up period of 3 to 14 month, none except one developed recurrence of the symptom. On the basis of our experience, we believe that metallic stent is safe and effective for the treatment of iliac arterial stenosis. However, we think that it is a complementary measure to the percutaneous transluminal angioplasty. The comparative study between different types of metallic stent and the long term effect should be investigated further.

  11. The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Li Zhengran; Zhu Kangshun; Guan Shouhai; Qian Jiesheng; Chen Guihua; Lu Minqiang; Yang Yang

    2006-01-01

    Purpose: This retrospective study was undertaken to evaluate the effectiveness of coronary stent placement in hepatic artery stenosis after orthotopic liver transplantation (OLT). Materials and methods: Of 430 consecutive adult orthotopic liver transplant recipients between November 2003 and September 2005, 17 had hepatic artery stenosis (HAS). Fourteen of them underwent coronary stent placement in the HAS. The technical results, complications, hepatic artery patency and clinical outcome were reviewed. Results: Technical and immediate success was 100%. After a mean follow-up of 159.4 days (range, 9-375 days), all patients obtained patent hepatic arteries except 2 patients occurred hepatic artery restenoses at 26 and 45 days after stent placement, respectively. Kaplan-Meier curve of patency showed cumulated stent patency at 3, 6, and 12 months of 78%, 58% and 45%, respectively. During the follow-up, 8 patients survived, 5 died of septic multiple-organ failure, 1 received retransplantation because of refractory biliary infection. Hepatic artery dissection induced by a guiding catheter occurred in one patient and was successfully treated with a coronary stent. Conclusion: Hepatic artery stenosis after OLT can be successfully treated with coronary stent placement with low complication rate and an acceptable 1-year hepatic artery patency rate

  12. Therapies targeting inflammation after stent implantation.

    Science.gov (United States)

    Okura, Hiroyuki; Takagi, Tsutomu; Yoshida, Kiyoshi

    2013-07-01

    Since the introduction of coronary vessel scaffold by metallic stent, percutaneous coronary intervention has become widely performed all over the world. Although drug-eluting stent technology has further decrease the incidence of in-stent restenosis, there still remaining issues related to stent implantation. Vessel inflammation is one of the causes that may be related to stent restenosis as well as stent thrombosis. Therefore, systemic therapies targeting inflammation emerged as adjunctive pharmacological intervention to improve outcome. Statins, corticosteroids, antiplatelets, and immunosuppresive or anti-cancer drugs are reported to favorably impact outcome after bare-metal stent implantation. In type 2 diabetic patients, pioglitazone may be the most promising drug that can lower neointimal proliferation and, as a result, lower incidence of restenosis and target lesion revascularization. On the other hand, several new stent platforms that might decrease inflammatory response after drug-eluting stent implantation have been introduced. Because durable polymer used in the first generation drug-eluting stents are recognized to be responsible for unfavorable vessel response, biocompatible or bioabsorbable polymer has been introduce and already used clinically. Furthermore, polymer-free drug-eluting stent and bioresorbable scaffold are under investigation. Although vessel inflammation may be reduced by using these new drug-eluting stents or scaffold, long-term impact needs to be investigated further.

  13. Wingspan stent system in the treatment of symptomatic intracranial atherosclerotic stenosis

    International Nuclear Information System (INIS)

    Li Tianxiao; Li Zhaoshuo; Wang Ziliang; Xue Jiangyu; Bai Weixing; Li Li; Zhai Shuiting; Feng Yingpu

    2010-01-01

    Objective: To assess the safety, feasibility, short- and mid-term efficacy of wingspan stent for treating patients with symptomatic intracranial artery stenosis. Methods: A total of 113 patients with severe symptomatic intracranial stenosis were enrolled and Gateway-wingspan stenting were performed on all patients. The technical success, the pre- and post-stenting stenosis, perioperative complications, clinical outcome and restenosis rates were recorded, and chi-square test was used for analysis of complication rate by comparing our results with the results of Warfarin-Aspirin Symptomatic Intracranial Disease (WASID) study and NIH multi-center Wingspan stenting trial. Results: The technical success rate was 99.1% (112/ 113). The mean pre and post-stent stenoses were (80.7±9.3)% and (27.7±9.7)% (χ 2 =9.397, P<0.05). The total complication rate was 4.4% (5/113) during the follow-up (mean 14.5 months, range 1-28 months), and the frequency of' restenosis was 12.5% (5/40) at 6 months. The primary endpoint events, ischemic stroke, and lesion-related ischemic stroke were lower in our study (4.5%, 3.5%, 3.5%) compared with the results of WASID trial (21.1%, 20.4%, 15.0%, P<0.05). For those with poor outcome in the three high-risk sub-groups which were with more than 70% stenosis, or last event from the treatment was less than 17 days, or NIHSS was above 1, a better outcome was observed in our group (4.5%, 4.7% and 2.0% in our study, 19.0%, 17.0% and 19.6% in previous study, P<0.05). The medium-term efficacy in this group (4.5%) significantly improved compared with NIH study (14.0%, P< 0.05). Conclusions: Wingspan stenting for symptomatic intracranial arterial stenosis is with good safety, feasibility and low perioperative stroke rate and mortality. The incidence of primary endpoint events and the ischemic events are lower than those of medication group, and the efficacy of stenting is significantly better than medication even in high-risk population. (authors)

  14. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  15. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  16. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000235.htm Angioplasty and stent placement - carotid artery - discharge To use the sharing ... the hospital. You may have also had a stent (a tiny wire mesh tube) placed in the ...

  17. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain; Thouvenot, Eric

    2010-01-01

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS ≤1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  18. [Value of the optical coherence tomography in the treatment guided of the stent failure. Case report].

    Science.gov (United States)

    Macías, Enrico; Tellez, Alejandro; Ochoa, Jorge; Ortíz, José E

    2014-01-01

    Since the advent of bare metal and drug-eluting stents, the surgical revascularization have declined considerably, however the thrombosis and in-stent restenosis are important complications of these devices. There are several factors that predispose to thrombosis and in-stent restenosis. Conventional angiography has serious limitations to determine the causes of stent failure. Optical coherence tomography is a very sensitive technique to determine the cause of thrombosis and in-stent restenosis. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  19. Primary stent placement for recanalization of iliac artery occlusions: Using a self-expanding spiral stent

    International Nuclear Information System (INIS)

    Kim, Jae-Kyu; Kim, Yun-Hyeon; Chung, Sang-Yeung; Kang, Heoung-Keun

    1999-01-01

    Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent.Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients's chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed.Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery, and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively.Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.

  20. Platelet deposition at angioplasty sites and its relation to restenosis in human iliac and femoropopliteal arteries

    International Nuclear Information System (INIS)

    Minar, E.; Ehringer, H.; Ahmadi, R.; Dudczak, R.; Leitha, T.; Koppensteiner, R.; Jung, M.; Stuempflen, A.

    1989-01-01

    The amount and time course of platelet accumulation at angioplasty sites and influence of these platelets on restenosis after percutaneous transluminal angioplasty (PTA) in peripheral arteries were determined in 92 patients, who received either a high or low dose of aspirin. Platelet deposition was quantitated by means of dual-radiotracer scintigraphy and calculation of a platelet accumulation index (PAI). The PAI was higher (P less than .05) 4-6 hours after PTA compared with that on subsequent days. There was a trend toward greater platelet accumulation in vessels with extensive dissection. Platelet accumulation at the PTA site occurred with both doses of aspirin, with no differences between the two dosage groups. Twenty-one of 67 patients who underwent PTA in the femoropopliteal segment developed restenosis during a median follow-up of 14 months. The median PAI at 4-6 and 22-24 hours after PTA was significantly less in these 21 patients than in the 46 without restenosis. The data suggest that use of antiplatelet agents to prevent platelet deposition after PTA may not be useful for prevention of restenosis

  1. Experimental research of covered stent implanted in canine hepatic artery

    International Nuclear Information System (INIS)

    Zhou Bing; Liu Linxiang; Li Minghua; Wang Yongli; Cheng Yongde

    2007-01-01

    Objective: To evaluate the feasibility of success rate of implantation, post-procedure stenosis rate, apposition ability and endothelialization level, etc. for implantation with balloon-expandable covered stent in canine hepatic artery. Methods: 8 adult canines were implanted with balloon-expendable stents covered by expandable poly Teflon ester membrane (e-PTFEM). Follow-up DSA was performed immediately, 2, 4 and 12 wk after the procedure. The canines were sacrificed for histopathologic examination and statistical analysis with correlation of implantation manenvor and angiographic manifestations. Results: 8 cases were all implanted with the covered stents in proper hepatic artery/right hepatic artery successfully; showing good apposition ability and non-opacification of the separated branches. 2 cases showed intraluminal obvious stenosis( > 50%)of the stent at 2 weeks follow-up, so did 3 cases at 12 weeks follow-up, and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization (3 different locations of the sample all manifested full endothelialization), 3 cased manifested partial endothelialization (at least 1 location of the sample didn't show full endothelialization), and the two terminal parts were easier to get endothelialization than the central part. Before and after the stent implantation, hepatic function of all cases didn't demonstrate any obvious changes. Conclusions: Balloon-expandable covered stent can be implanted in canine hepatic artery. successfully, with good apposition ability, full endothelialization, and no influence on hepatic function. (authors)

  2. Brachytherapy on restenosis. {sup 32}P radioisotope in animal model

    Energy Technology Data Exchange (ETDEWEB)

    Bergoc, R.; Rivera, E.; Cocca, C.; Martin, G.; Cricco, G. [Buenos Aires Univ. (Argentina). School of Pharmacy and Biochemistry; Croci, M.; Guzman, L.

    2000-05-01

    Despite a notorious decline in age-adjusted death rates for cardiovascular pathologies, coronary artery disease still remains as the main cause of mortality above the age of 40 in men and 60 in women. More than 25% of death in persons over the age of 35 are due to coronary disease. In about 50% of men and 30% of women, the first manifestation of the disease is an acute myocardial infarction and 10% a sudden cardiac death. In Argentina it is estimated that in 1998 about 100.000-115.000 people suffered as first manifestation of coronary illness a myocardial acute infarct. Angioplasty has an important and well established site in the treatment of the coronary illness and restenosis represents the principal complication of this method for myocardial re-vascularization. About a 35-40% of treated arteries present restenosis within the first six month the intervention with the concomitant need of re-interventions, re-hospitalizations, by-pass surgery, work discontinuity and the high cost for the health system. A number of drugs were tested as anti-restenosis: anticoagulants, aspirin, antispasmodics and lipid-lowering agents but none was clearly efficient; also, experimental studies in which intravascular irradiation with different source types and energies, radiation doses and doses rate to prevent restenosis was utilized; however, there is no consensus in many aspects of this intravascular brachytherapy. The first step in this work was to induce the experimental model in rabbits. Afterwards, by means of the balloon methodology and stent implantation, brachytherapy experiments were carried out to evaluate the biological effect on different layers of arteries, with different Doses using a beta particle emitting radioisotope ({sup 32}P). The arteriosclerotic lesions were induced in New Zealand rabbits through the administration of a diet with high cholesterol content. Angioplastic interventions on femoral arteries were done with balloon methodology and controlled by

  3. Stenting of the SFA - indications, techniques,

    International Nuclear Information System (INIS)

    Rieger, J.; Treitl, M.; Reiser, M.; Ruppert, V.

    2006-01-01

    Aggressive risk factor modification, change of eating habits, exercise programs, and forceful antiplatelet therapy are the most important tools for the treatment of PAOD in symptomatic patients suffering from intermittent claudication. There are however no guidelines for revascularization at this stage. Endovascular treatment has been increasingly utilized over the last decade and increasingly displaced vascular surgery. Amongst numerous endovascular techniques beside PTA, stents meanwhile play the most important role due to constant technical progress. Results regarding the rate of restenosis or patency rates still remain worse compared to other vascular beds. This paper gives a review over recent results, currently available stent techniques, and possible indications for the endovascular therapy of an artery, which has turned out to be the biggest ordeal for material and construction of stents. (orig.) [de

  4. Efficacy of beta radiation in prevention of post-angioplasty restenosis : An interim report from the beta energy restenosis trial

    NARCIS (Netherlands)

    D. Meerkin; R. Bonan (Raoul); I.R. Crocker; A. Arsenault (André); P. Chougule; V.L.M.A. Coen (Veronique); D.O. Williams (David); P.W.J.C. Serruys (Patrick); S.B. King 3rd (Spencer)

    1998-01-01

    textabstractRestenosis remains a major limitation of coronary angioplasty in spite of major advances in techniques and technology. Recent studies have demonstrated that ionizing radiation may limit the degree of this problem. Gamma radiation has been shown to be effective in reducing in stent

  5. Successful Expansion of an Underexpanded Stent by Rotational Atherectomy

    Science.gov (United States)

    Vales, Lori; Coppola, John; Kwan, Tak

    2013-01-01

    The current routine use of intracoronary stents in percutaneous coronary intervention (PCI) has significantly reduced rates of restenosis, compared with balloon angioplasty alone. On the contrary, small post-stenting luminal dimensions due to undilatable, heavily calcified plaques have repeatedly been shown to significantly increase the rates of in-stent restenosis. Rotational atherectomy of lesions is an alternative method to facilitate PCI and prevent underexpansion of stents, when balloon angioplasty fails to successfully dilate a lesion. Stentablation, using rotational atherectomy to expand underexpanded stents deployed in heavily calcified plaques, has also been reported. We report a case via the transradial approach of rotational-atherectomy–facilitated PCI of in-stent restenosis of a severely underexpanded stent due to a heavily calcified plaque. We review the literature and suggest rotational atherectomy may have a role in treating a refractory, severely underexpanded stent caused by a heavily calcified plaque through various proposed mechanisms. PMID:24436587

  6. Introduction of a high-throughput double-stent animal model for the evaluation of biodegradable vascular stents.

    Science.gov (United States)

    Borinski, Mauricio; Flege, Christian; Schreiber, Fabian; Krott, Nicole; Gries, Thomas; Liehn, Elisa; Blindt, Rüdiger; Marx, Nikolaus; Vogt, Felix

    2012-11-01

    Current stent system efficacy for the treatment of coronary artery disease is hampered by in-stent restenosis (ISR) rates of up to 20% in certain high-risk settings and by the risk of stent thrombosis, which is characterized by a high mortality rate. In theory, biodegradable vascular devices exhibit crucial advantages. Most absorbable implant materials are based on poly-L-lactic acid (PLLA) owing to its mechanical properties; however, PLLA might induce an inflammatory reaction in the vessel wall. Evaluation of biodegradable implant efficacy includes a long-term examination of tissue response; therefore, a simple in vivo tool for thorough biocompatibility and biodegradation evaluation would facilitate future stent system development. Rats have been used for the study of in vivo degradation processes, and stent implantation into the abdominal aorta of rats is a proven model for stent evaluation. Here, we report the transformation of the porcine double-stent animal model into the high-throughput rat abdominal aorta model. As genetic manipulation of rats was introduced recently, this novel method presents a powerful tool for future in vivo biodegradable candidate stent biocompatibility and biodegradation characterization in a reliable simple model of coronary ISR. Copyright © 2012 Wiley Periodicals, Inc.

  7. Successful treatment of coronary artery pseudoaneurysm by graft stent, which developed after the implantation of bare metal stent

    Directory of Open Access Journals (Sweden)

    Utku Şenol

    2013-03-01

    Full Text Available Although coronary artery pseudoaneurysm which couldoccur following percutaneous coronary interventions is arare complication, it can be mortal. As soon as the pseudoaneurysmis diagnosed, it should be treated by percutaneousintervention or surgery. Graft stent implantationis a preferred treatment for appropriate patients. In thiscase report, we presented a successful treatment of coronaryartery pseudoaneurysm by graft stent; which developedafter the implantation of bare metal stent into theleft anterior descending coronary artery. J Clin Exp Invest2013; 4 (1: 126-129Key words: Coronary artery, pseudoaneurysm, graft stent

  8. Complications related to conventional self-expandable metal stent insertion and internal irradiation stent insertion in patients with advanced esophageal carcinoma: an analysis of 32 cases

    International Nuclear Information System (INIS)

    Xu Xingwen; Di Haiting; Zhu Jun; Shi Jian

    2011-01-01

    Objective: To compare the occurrence of complications between conventional self-expandable metal stent and internal irradiation stent insertion in treating patients with advanced esophageal carcinomas. Methods: A total of 32 patients with advanced esophageal carcinoma were randomly divided into irradiation stent group (n=15) and conventional stent group (n=17). Internal irradiation stent loaded with 125 I seeds was employed in patients of irradiation stent group, while conventional self-expandable metal stent was used in patients of conventional stent group. After the treatment, clinical follow-up was regularly conducted. Postoperative complications such as fever, severe chest pain, cough, esophageal perforation, pneumonia, hemorrhage, stent migration and restenosis, etc. were observed. Results: No significant difference in the occurrence of fever, severe chest pain, esophageal perforation and hemorrhage existed between the two groups (P>0.05). The difference in the occurrence of long-term complications such as stent migration or restenosis between the two groups was out statistically significant (P>0.05). However, the restenosis in irradiation stent group occurred obviously much later than that in conventional stent group. Conclusion: For the treatment of advanced esophageal carcinomas, the insertion of internal irradiation esophageal stent is safe. It dose not increase the incidence of postoperative complications. Therefore, it is worth popularizing this technique in clinical practice. (authors)

  9. Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization

    International Nuclear Information System (INIS)

    Joo, Jin Yang; Ahn, Jung Yong; Chung, Young Sun; Han, In Bo; Chung, Sang Sup; Yoon, Pyeong Ho; Kim, Sang Heum; Choi, Eun Wan

    2005-01-01

    Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesion was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series

  10. Self-Expandable Stent Placement in Infrapopliteal Arteries After Unsuccessful Angioplasty Failure: One-Year Follow-up

    International Nuclear Information System (INIS)

    Peregrin, J. H.; Smirova, S.; Koznar, B.; Novotny, J.; Kovac, J.; Lastovickova, J.; Skibova, J.

    2008-01-01

    The purpose of this prospective study was to evaluate whether stent placement in infrapopliteal arteries is helpful in failed percutaneous transluminal angioplasty (PTA). Infrapopliteal PTA was performed in 70 arteries of 66 patients with chronic critical lower limb ischemia. The group comprised 55 males and 11 females, with an average age of 63.4 (range, 42-82) years. Diabetes mellitus was present in 92.4% of patients. Only the palpable anterior tibial and posterior tibial arteries were evaluated. Stents (Xpert stent; Abbot Vascular, Redwood City, CA, USA) were placed in 16 arteries where PTA was not successful (the failure was defined as residual stenosis >30% after PTA). In 54 arteries simple PTA was performed and was technically successful. Twenty-four nondilated arteries with no significant stenosis served as a comparison group. The 12-month patency rate was evaluated according to a combination of palpation and Doppler ultrasound. In all cases stent placement restored the flow in the artery immediately after unsuccessful PTA. Twelve-month follow-up showed a patency rate of 82% in the PTA group, 78% in the stent group, and 69% in the comparison group. We conclude that stent placement in the case of unsuccessful infrapopliteal PTA changed technical failure to success and restored flow in the dilated artery. At 12-month follow-up the patency rate of infrapopliteal arteries stented for PTA failure did not differ significantly either from nonstented arteries with an optimal PTA result or from a comparison group of nonintervened arteries.

  11. Critical appraisal of paclitaxel balloon angioplasty for femoral–popliteal arterial disease

    Directory of Open Access Journals (Sweden)

    Herten M

    2016-08-01

    Full Text Available Monika Herten,1 Giovanni B Torsello,1,2 Eva Schönefeld,3 Stefan Stahlhoff2 1Department of Vascular and Endovascular Surgery, University Hospital Münster, 2Department of Vascular Surgery, St Franziskus Hospital, Münster, 3Institute for Education and Student Affairs, University Hospital Münster, Münster, Germany Abstract: Peripheral arterial disease, particularly critical limb ischemia, is an area with urgent need for optimized therapies because, to date, vascular interventions often have limited life spans. In spite of initial encouraging technical success after femoropopliteal percutaneous transluminal angioplasty or stenting, postprocedural restenosis remains the major problem. The challenging idea behind the drug-coated balloon (DCB concept is the biological modification of the injury response after balloon dilatation. Antiproliferative drugs administered via DCBs or drug-eluting stents are able to suppress neointimal hyperplasia, the main cause of restenosis. This article reviews the results of DCB treatments of femoropopliteal and infrapopliteal lesions in comparison to standard angioplasty with uncoated balloons. A systematic literature search was performed in 1 medical journals (ie, MEDLINE, 2 international registers for clinical studies (ie, www.clinicaltrials.gov, and 3 abstracts of scientific sessions. Several controlled randomized trials with follow-up periods of up to 5 years demonstrated the efficacy of paclitaxel –DCB technology. However, calcified lesions seem to affect the efficacy of DCB. Combinations of preconditioning methods with DCBs showed promising results. Although the mechanical abrasion of calcium via atherectomy or laser ablation showed favorable periprocedural results, the long-term impact on restenosis and clinical outcome has to be demonstrated. Major advantages of the DCBs are the rapid delivery of drug at uniform concentrations with a single dose, their efficacy in areas wherein stents have been

  12. Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) trial

    NARCIS (Netherlands)

    D.R. Holmes Jr (David); J.R. Granett (Jeffrey); J.J. Popma (Jeffrey); P.J. Fitzgerald (Peter); D. Fischman (David); J.J. Ferguson (James); A.M. Lincoff (Michael); S. Goldberg (Sheldon); J.A. Brinker; R. Chan; B.R. Davis (Barry); M. Poland; A.M. Zeiher (Andreas); J.T. Willerson (James); S.B. King 3rd (Spencer); L.M. Shapiro; M. Savage (Michael); J.M. Lablanche (Jean Marc); J.E. Tcheng (James); L. Grip (Lars); P.W.J.C. Serruys (Patrick)

    2002-01-01

    textabstractBACKGROUND: Restenosis after percutaneous coronary intervention (PCI) is a major problem affecting 15% to 30% of patients after stent placement. No oral agent has shown a beneficial effect on restenosis or on associated major adverse cardiovascular events. In limited trials, the oral

  13. Wingspan stent-assisted coiling of intracranial aneurysms with symptomatic parent artery stenosis: Experience in 35 patients with mid-term follow-up results

    International Nuclear Information System (INIS)

    Gao Xu; Liang Guobiao; Li Zhiqing; Wei Xuezhong; Wang Xiaogang; Zhang Haifeng; Feng Sizhe; Lin Jun

    2012-01-01

    patients (5.7%), including thromboembolism (n = 1) and occlusion of small penetrating arteries (n = 1). At follow-up (mean time 18.3 months), two additional cases of ischemic stroke occurred. The overall frequency of any stroke, intracranial hemorrhage, or death within 30 days or ipsilateral stroke beyond 30 days was 11.4%. No rehemorrhage of treated aneurysm occurred. At angiographic follow-up, four cases demonstrated ≥50% in-stent restenosis (12.9%), one of which was symptomatic, and two aneurysms (6.4% of the follow-up angiograms) demonstrated recanalization. Conclusion: We found that the Wingspan stent-assisted coil embolization was helpful in the treatment of intracranial aneurysms with parent artery stenosis.

  14. Transpedal approach for iliac artery stenting: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Zachariah, Jips J., E-mail: jzachariah@chpnet.org [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Ratcliffe, Justin A.; Ruisi, Michael; Puma, Joseph [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Bertrand, Olivier [Quebec Heart and Lung Institute, Quebec (Canada); Kwan, Tak [Mount Sinai Beth Israel Hospital, New York, NY (Israel)

    2016-12-15

    Objective: To demonstrate the safety and feasibility of the transpedal approach as an alternate arterial access site for iliac artery intervention. Background: The common femoral artery is the traditional access site for the endovascular treatment of iliac artery stenoses. However, this approach is associated with complication rates as high as 2%, including retroperitoneal bleeding which carries high patient morbidity and mortality. Furthermore, the standard femoral approach is associated with longer recovery times and longer time to ambulation which are important considerations especially when performing procedures in an ambulatory setting. Methods: Twelve patients were prospectively followed after treatment for symptomatic iliac artery stenosis via transpedal access. Under ultrasound guidance, one of the pedal arteries was visualized and accessed, and stenting of the iliac arteries were performed as per protocol. The patient was monitored immediately post procedure and clinical follow up was performed at one week and one month later. Results: The average age of the patients was 71 years old. 58% were male. Most patients had Rutherford class III symptoms. Successful stent placement was achieved in all 12 patients via transpedal access. No conversion to femoral access was required. No complications immediately post procedure nor at any time period during follow up were noted. Lower extremity arterial duplex at one month showed patent stents and patent pedal access site vessels in all patients. Conclusion: Transpedal arterial access may be a safe and feasible approach for iliac artery stenting. Given the possible benefits of avoiding femoral artery access, larger studies should be conducted directly comparing the different approaches.

  15. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul

    2011-01-01

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 ± 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  16. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2011-07-15

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 {+-} 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  17. Therapeutic evaluation of retrievable esophageal covered stent in treating achalasia

    International Nuclear Information System (INIS)

    Li Yuwei; Zhang Fuqiang; Yuan Liang; Li Yunhui; Luo Bin; Yu Li; Sun Dingqiang

    2010-01-01

    Objective: To evaluate the clinical effect of retrievable esophageal covered metal internal stent in treating patients with achalasia. Methods: Under DSA guidance, peroral 'Z-type' double horn covered metal internal stent implantation was performed in 16 patients with achalasia. Esophagography was carried out about 28 days after the procedure and the stent was retrieved. Results: Of 16 cases, the stent fell off into the stomach two weeks after the operation in one. And the stent was successfully replaced after it was taken out. The placed stent was successfully retrieved in all cases 28 days after the treatment. No serious complications occurred. All the patients were followed up for 3 months to 3 years. During the follow-up period restenosis of the esophagus developed in two cases (at one and 1.5 years respectively), and the restenosis degree was relived after balloon dilation. Clinically, no esophageal symptoms, such as dysphagia, occurred in all patients. Conclusion: As a simple and safe technique, the retrievable esophageal covered metal internal stent implantation is very effective with fewer complications for the treatment of achalasia. Moreover, the technique carries lower restenosis occurrence. (authors)

  18. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  19. Complications and Follow-up after Unprotected Carotid Artery Stenting

    International Nuclear Information System (INIS)

    Hauth, Elke A.M.; Drescher, Robert; Jansen, Christian; Gissler, H. Martin; Schwarz, Michael; Forsting, Michael; Jaeger, Horst J.; Mathias, Klaus D.

    2006-01-01

    Purpose. This prospective study was undertaken to determine the success rate, complications, and outcome of carotid artery stenting (CAS) without the use of cerebral protection devices. Methods. During 12 months, 94 high-grade stenoses of the carotid artery in 91 consecutive patients were treated. Sixty-six (70%) of the stenoses were symptomatic and 28 (30%) were asymptomatic. Results. In all 94 carotid stenoses CAS was successfully performed. During the procedure and within the 30 days afterwards, there were 2 deaths and 3 major strokes in the 66 symptomatic patients, resulting in a combined death and stroke rate of 5 of 66 (7%). Only one of these complications, a major stroke, occurred during the procedure. In the 6-month follow-up, one additional major stroke occurred in a originally symptomatic patient resulting in a combined death and stroke rate of 6 of 66 (10%) for symptomatic patients at 6 months. No major complications occurred in asymptomatic patients during the procedure or in the 6-month follow-up period. At 6 months angiographic follow-up the restenosis rate with a degree of >50% was 3 of 49 (6%) and the rate with a degree of ≥70% was 1 of 49 (2%). Conclusions. Cerebral embolization during CAS is not the only cause of the stroke and death rate associated with the procedure. The use of cerebral protection devices during the procedure may therefore not prevent all major complications following CAS

  20. Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.

    Science.gov (United States)

    Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I

    2017-04-01

    Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.

  1. Zilver PTX Post-Market Surveillance Study of Paclitaxel-Eluting Stents for Treating Femoropopliteal Artery Disease in Japan: 12-Month Results.

    Science.gov (United States)

    Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Snyder, Scott A; Dake, Michael D

    2016-02-08

    This multicenter, prospective, post-market surveillance study in Japan evaluates the paclitaxel-coated Zilver PTX stent in real-world patients with complex lesions. The Zilver PTX stent is the first drug-eluting stent (DES) approved for the superficial femoral artery. Previously, results from a large randomized study and a complementary, large single-arm study supported the safety and effectiveness of the DES. There were no exclusion criteria, and consecutive patients with symptomatic peripheral artery disease (PAD) treated with the DES were enrolled in the study. Clinically driven target lesion revascularization (TLR) was defined as reintervention performed for ≥50% diameter stenosis after recurrent clinical symptoms of PAD. Clinical benefit was defined as freedom from persistent or worsening symptoms of ischemia. Patency was evaluated by duplex ultrasound where physicians considered this standard of care. In this study, 907 patients were enrolled at 95 institutions in Japan. There were numerous comorbidities including high incidences of diabetes (58.8%), chronic kidney disease (43.8%), and critical limb ischemia (21.5%). Lesions were also complex, with an average length of 14.7 cm, 41.6% total occlusions, and 18.6% in-stent restenosis. In total, 1,861 DES were placed in 1,075 lesions. Twelve-month follow-up was obtained for >95% of eligible patients. Freedom from TLR was 91.0%, and clinical benefit was 87.7% through 12 months. The 12-month primary patency rate was 86.4%. Despite more challenging lesions, results from the current study are similar to outcomes from the previous Zilver PTX studies, confirming the benefit of the Zilver PTX DES in a real-world patient population. (Zilver PTX Post-Market Study in Japan; NCT02254837). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Luminal flow amplifies stent-based drug deposition in arterial bifurcations.

    Directory of Open Access Journals (Sweden)

    Vijaya B Kolachalama

    2009-12-01

    Full Text Available Treatment of arterial bifurcation lesions using drug-eluting stents (DES is now common clinical practice and yet the mechanisms governing drug distribution in these complex morphologies are incompletely understood. It is still not evident how to efficiently determine the efficacy of local drug delivery and quantify zones of excessive drug that are harbingers of vascular toxicity and thrombosis, and areas of depletion that are associated with tissue overgrowth and luminal re-narrowing.We constructed two-phase computational models of stent-deployed arterial bifurcations simulating blood flow and drug transport to investigate the factors modulating drug distribution when the main-branch (MB was treated using a DES. Simulations predicted extensive flow-mediated drug delivery in bifurcated vascular beds where the drug distribution patterns are heterogeneous and sensitive to relative stent position and luminal flow. A single DES in the MB coupled with large retrograde luminal flow on the lateral wall of the side-branch (SB can provide drug deposition on the SB lumen-wall interface, except when the MB stent is downstream of the SB flow divider. In an even more dramatic fashion, the presence of the SB affects drug distribution in the stented MB. Here fluid mechanic effects play an even greater role than in the SB especially when the DES is across and downstream to the flow divider and in a manner dependent upon the Reynolds number.The flow effects on drug deposition and subsequent uptake from endovascular DES are amplified in bifurcation lesions. When only one branch is stented, a complex interplay occurs - drug deposition in the stented MB is altered by the flow divider imposed by the SB and in the SB by the presence of a DES in the MB. The use of DES in arterial bifurcations requires a complex calculus that balances vascular and stent geometry as well as luminal flow.

  3. Agreement of duplex ultrasonography vs. computed tomography angiography for evaluation of native and in-stent SFA re-stenosis—Findings from a randomized controlled trial

    International Nuclear Information System (INIS)

    Langenberger, Herbert; Schillinger, Martin; Plank, Christina; Sabeti, Schila; Dick, Petra; Cejna, Manfred; Lammer, Johannes; Minar, Erich; Loewe, Christian

    2012-01-01

    Background: Multidetector CT angiography (CTA) is a non-invasive imaging technique for evaluation of peripheral vascular disease. CTA might be particularly useful for assessment of intermediate- and long-term morphological outcome after endovascular treatment. Validation of CTA vs. the current imaging standard, colour Doppler ultrasonography (CDUS), for quantification of native and in-stent re-stenosis in the superficial femoral artery (SFA) is required. Methods: Seventy randomized patients who underwent stent implantation (n = 47) or balloon angioplasty (n = 23) underwent 6-month follow-up with CDUS and CTA. CTA was compared with CDUS in both sub-groups of patients in terms of binary re-stenosis (>50% lumen narrowing) and re-occlusion. Agreement between CTA and CDUS was assessed using Kappa (κ) statistics with 95% confidence intervals, and correlation coefficients. Results: Binary re-stenosis was detected in 16/70 (22.9%) patients by CTA and 17/70 (24.3%) patients by CDUS (κ = 0.88, 95% CI: 0.80–0.96). Re-stenosis rates after balloon angioplasty were 39.1% (9/23) on CTA and CDUS (κ = 0.82, 95% CI: 0.66–0.98), and after stent implantation 14.9% (7/47) on CTA and 17.0% (8/47) on CDUS (κ = 0.92, 95% CI: 0.84–1.00). Re-occlusions were detected in 3/70 (4.3%) patients by both CTA and CDUS (κ = 0.65; 95% CI 0.54–0.76). Significant correlations (r = 0.85, p < 0.001) were noted between degree of re-stenosis on CTA and peak velocity ratio on CDUS. The correlation coefficient was higher in patients after balloon angioplasty (r = 0.94, p < 0.001) than in patients after stent implantation (r = 0.71, p < 0.001). Conclusion: CTA and CDUS show excellent agreement for evaluation of native and in-stent re-stenosis after endovascular treatment of SFA obstructions. CTA is an appropriate non-invasive imaging modality for follow-up after endovascular therapy

  4. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    Science.gov (United States)

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  5. Indications and applications of arterial stents for stroke prevention in atherosclerotic intracranial stenosis.

    Science.gov (United States)

    Fields, Jeremy D; Liu, Kenneth C; Barnwell, Stanley L; Clark, Wayne M; Lutsep, Helmi L

    2010-01-01

    Intracranial stenosis accounts for 8-10% of all ischemic strokes in North America, a frequency slightly less than that of extracranial carotid stenosis. Among patients presenting with transient ischemic attack or stroke due to intracranial stenosis, the risk of recurrent stroke in the first year after initial symptoms is about 14%. Those with high-risk features (recent stroke and severe stenosis) have up to a 23% rate of recurrent stroke in the year after their initial event. Angioplasty with stenting has emerged as a potential treatment strategy, particularly in high-risk patients, although evidence is currently limited to uncontrolled prospective trials and retrospective case series. In this article, we critically review the clinical results supporting the use of stenting and highlight some key considerations in the application of this technology, including patient selection, procedural management, technical issues, and risk factors for complications and in-stent restenosis.

  6. Interventional treatment of arterial complications in post renal transplantation

    International Nuclear Information System (INIS)

    Qian Xiaojun; Dai Dingke; Zhai Renyou

    2004-01-01

    Objective: To report our experience of interventional procedure for arterial complications in post renal transplantation and to evaluate its clinical value. Methods: In a retrospective analysis of renal transplantations in our center, 52 cases of renal allograft artery abnormalities had taken angiography. Interventional procedure included transluminal angioplasty of arterial stenoses, treatment of arterial occlusion, and embolization of pseudoaneurysm. Results: Renal allograft artery abnormalities included artery stenosis (n=21), artery thrombosis (n=13) and embolision (n=1), renal artery pseudoaneurysms (n=2), and decrease of renal artery flow (n=3). Of the 21 artery stenosis, 2 grafts with artery stenosis were lost because the stenosis could not be corrected, and 3 with mild stenosis received no treatment. Another 16 accepted renal artery angioplasty (balloon dilation, n=12, and stent implantation, n=4). 14 achieved long-term allograft function. 1 graft was lost because renal function failed to recover. Restenosis occurred in one stent implantation, and lost the allograft function after secondary dilation. 13 cases received thrombolytic therapy through artery catheter for thrombosis and 9 achieved long-term allograft function. Thrombolyses failed in 3 cases, and renal function failed to recover in 1 case. One pseudoaneurysm received stent implantation after embolization, and got a short-term allograft function. The other one received allograft excision. Conclusion: Intravascular interventional therapy will be the first-line therapy for any indications of complication in post renal transplantation, and it can surely save the kidney in a majority of instances. (authors)

  7. StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions

    OpenAIRE

    Cura, Fernando; Albertal, Mariano; Candiello, Alfonsina; Nau, Gerardo; Bonvini, Victor; Tricherri, Hernan; Padilla, Lucio T.; Belardi, Jorge A.

    2013-01-01

    Introduction Inadequate stent implantation is associated with stent thrombosis and restenosis. StentBoost can enhance stent visualization and evaluate stent expansion. Currently, there are limited comparison studies between StentBoost and intravascular ultrasound (IVUS). We aimed to test the correlation and agreement between IVUS and StentBoost measurements. Methods From December 2010 to December 2011, 38 patients (54 stents) were analyzed using IVUS and StentBoost. Minimal stent diameter and...

  8. Treatment of carotid-siphon aneurysms by using willis stent-graft: an angiographic and histopathologic study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Xie Jian; Tan Huaqiao; Cheng Yingsheng; Wang Jianbo

    2010-01-01

    Objective: To establish a carotid siphon aneurysm model in dogs in order to test the mechanical features of a newly-designed Willis covered stent-graft and to investigate the histological reaction of the stent-implanted vessel during a follow-up period of 12 months. Methods: Twenty-four saccular sidewall aneurysms were surgically created in twelve dogs (group A) and 12 carotid siphon aneurysms in another twelve dogs (group B). A Willis stent-graft was implanted in each aneurysm. Angiography was performed immediately after the procedure and 1, 3, 6 and 12 months after the implantation to investigate the aneurysm isolation, endoleak, stent angulation, and the patency or restenosis of the parent artery. Light and scanning electronic microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress of the stent-loaded arterial segment. Results: In group B, postoperative immediate angiography demonstrated that two aneurysms had mild endoleak and three stents became angulated. Follow-up exam 12 months after the procedure revealed that all previous endoleaks disappeared, one parent artery became occluded and three parent arteries developed mild stenosis (< 50%). In group A, occlusion of parent artery was seen in one and mild stenosis (< 50%) in 2 cases. Electronic microscopy revealed new intima formation in all stents, and all aneurysmal sacs were filled with thrombi. In group B, the endothelialization process was not completed until 12 months after the stent implantation, and a marked correlation existed between endothelial cell arrangement and the hemodynamic orientation. Conclusion: It is feasible to treat carotid-siphon aneurysm in dog with a Willis stent-graft. The complete endothelialization of the covered stent in tortuous vessel takes longer time than that in rather straight vessel. (authors)

  9. Impact of Chronic Renal Failure on Safety and Effectiveness of Paclitaxel-Eluting Stents for Femoropopliteal Artery Disease: Subgroup Analysis from Zilver PTX Post-Market Surveillance Study in Japan.

    Science.gov (United States)

    Ogawa, Yukihisa; Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Saunders, Alan T; Dake, Michael D

    2017-11-01

    Favorable long-term outcomes of the Zilver PTX drug-eluting stent (DES) in femoropopliteal lesions have been demonstrated. Chronic renal failure (CRF) has been shown to be a risk factor for restenosis and decreased limb salvage. The results of the DES in patients with CRF have not previously been reported. This study compares the results with the DES in patients with CRF and those without CRF. This retrospective analysis from the Zilver PTX Japan Post-Market Surveillance Study included 321 patients with CRF and 584 patients without CRF. Outcomes included freedom from target lesion revascularization (TLR) and patency. Of the patients included in this subgroup analysis, 2-year data were available for 209 patients in the CRF group and 453 patients in the non-CRF group. The two groups were similar in terms of lesion length and the frequency of in-stent restenosis. Critical limb ischemia, severe calcification, and diabetes were more common in patients with CRF, whereas total occlusion was more common in patients without CRF. Freedom from TLR rates were 81.4 versus 84.9% (p = 0.24), and patency rates were 70.7 versus 70.3% (p = 0.95) in patients with and without CRF at 2 years, respectively. This is the first comparative study of the DES in femoropopliteal artery lesions in patients with and without CRF. These results indicate that the DES placed in femoropopliteal artery lesions of CRF patients is safe and effective with similar patency and TLR rates to patients without CRF. Level 3, Post-Market Surveillance Study.

  10. Stent thrombosis and restenosis: what have we learned and where are we going? The Andreas Grüntzig Lecture ESC 2014

    Science.gov (United States)

    Byrne, Robert A.; Joner, Michael; Kastrati, Adnan

    2015-01-01

    Modern-day stenting procedures leverage advances in pharmacotherapy and device innovation. Patients treated with contemporary antiplatelet agents, peri-procedural antithrombin therapy and new-generation drug-eluting stents (DES) have excellent outcomes over the short to medium term. Indeed, coupled with the reducing costs of these devices in most countries there remain very few indications where patients should be denied treatment with standard-of-care DES therapy. The two major causes of stent failure are stent thrombosis (ST) and in-stent restenosis (ISR). The incidence of both has reduced considerably in recent years. Current clinical registries and randomized trials with broad inclusion criteria show rates of ST at or stent failure neoatherosclerotic change within the stented segment represents a final common pathway for both thrombotic and restenotic events. In future, a better understanding of the pathogenesis of this process may translate into improved late outcomes. Moreover, the predominance of non-stent-related disease as a cause of subsequent myocardial infarction during follow-up highlights the importance of lifestyle and pharmacological interventions targeted at modification of the underlying disease process. Finally, although recent developments focus on strategies which circumvent the need for chronically indwelling stents—such as drug-coated balloons or fully bioresorbable stents—more data are needed before the wider use of these therapies can be advocated. PMID:26417060

  11. Hybrid treatment of tandem, common carotid/innominate artery and ipsilateral carotid bifurcation stenoses by simultaneous, retrograde proximal stenting and eversion carotid endarterectomy: Preliminary results of a case series.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Pasqua, Rocco; Frezzotti, Francesca; Palumbo, Piergaspare; Macrina, Francesco; Calio', Francesco

    2018-04-01

    Tandem stenoses of the internal carotid artery (ICA) and proximal, ipsilateral common carotid artery (CCA) or innominate artery can be treated with a hybrid approach, combining conventional carotid endarterectomy (CEA) and retrograde stenting of the proximal stenosis, through surgical exposure of the carotid bifurcation. The purpose of this study was to evaluate the results of combining eversion CEA with retrograde CCA/innominate artery stenting. From January 2015 to July 2017, 7 patients, 6 men of a mean age of 72 years (range 59-83 years) underwent simultaneous, retrograde stenting of the proximal CCA/innominate artery and an eversion CEA of the ipsilateral ICA, through surgical exposure of the carotid bifurcation, for severe tandem stenoses. The proximal stenosis involved the left proximal CCA in 4 patients, the proximal innominate artery in 2 patients and the right CCA in one patient. The procedure was performed under general anesthesia in a conventional operating room equipped with a mobile C-arm. A covered, balloon expandable stent was deployed over the proximal stenosis via a 6-F sheath directly introduced into the proximal CCA through the obliquely transected carotid bulb. After removing the sheath, debris were flushed through the carotid bulb and eversion CEA completed the procedure. Study endpoints were: postoperative stroke/mortality rate, cardiac mortality and morbidity, peripheral nerve injury, cervical hematoma, overall late survival, freedom from ipsilateral stroke and patency of arterial reconstruction. No postoperative mortality or neurologic morbidity was observed in any patient. Cervical hematomas and peripheral nerve injuries were likewise absent. At a mean follow-up of 18 months, all the patients were alive, free from neurologic events of new onset and free from restenosis. Combined proximal stenting and eversion CEA for tandem lesions seems a valid treatment, with the advantages of eversion CEA over other techniques of carotid bifurcation

  12. Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

    International Nuclear Information System (INIS)

    Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko

    2013-01-01

    Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.

  13. Treatment of carotid artery aneurysms with covered stents; Aneurysmabehandlung der Arteria carotis interna mit gecoverten Stents

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, A.; Alfke, K.; Doerner, L.; Jansen, O. [UKSH Kiel (Germany). Neurochirurgie Neuroradiologie; Bartsch, T.; Stingele, R. [UKSH Kiel (Germany). Neurologie

    2007-10-15

    Purpose: Evaluation of the use of covered stents in treating pseudoaneurysms of the cervical and intracranial/extradural carotid artery and determination of the periprocedural and short- to mid-term complication rate. Materials and Methods: 8 patients with 9 spontaneous dissecting aneurysms of the cervical carotid artery - 5 of which were symptomatic - plus one patient with ofthalmoplegia due to an aneurysm of the cavernous carotid artery were studied. While the latter was treated with a PTFE-covered balloon-mounted stainless steel stent (Jostent/Graftmaster), a self-expanding PTFE-covered Nitonol Stent (Symbiot) was used in all other cases. Intervention was performed with local anesthesia. Aspirin and Clopidogrel were both used as antiplatelet drugs. Clinical signs and symptoms and vascular imaging with DS, MR, CT angiography and ultrasound were recorded during patient follow-up, with a mean follow-up period of 14.6 months (4 - 30). Results: We were able to treat 8 out of 10 aneurysms (80 %) using covered stents. The aneurysms were immediately occluded and the associated stenoses of the parent vessel were eliminated. No clinically relevant complications occurred during the procedure or in the follow-up interval. In two cases, elongation of the carotid artery prevented the stent from being positioned over the aneurysm neck. These cases were shown to be stable with the use of antiplatelet drugs. Conclusion: Covered stents can be used in the treatment of pseudoaneurysms of the carotid artery as an alternative to long-term antithrombotic medication or surgery. In our study treatment was effective (80 %) and free of complications in the short- and mid-term follow-up. Possible indications, technique and the use of imaging modalities for patient follow-up are discussed. (orig.)

  14. [Successful correction with stent-graft of coronary artery rupture after angioplasty].

    Science.gov (United States)

    Demin, V V

    2003-01-01

    Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.

  15. Comparison of closed-cell and hybrid-cell stent designs in carotid artery stenting: clinical and procedural outcomes

    Directory of Open Access Journals (Sweden)

    Ersan TatlI

    2017-05-01

    Full Text Available Introduction: Carotid artery stenting (CAS is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. Aim : To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. Material and methods : All CAS procedures with both closed- and hybrid-cell stents performed at our institution between February 2010 and December 2015 were analyzed retrospectively. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack and myocardial infarction. Periprocedural and 30-day adverse events and internal carotid artery (ICA vasospasm rates were compared between the closed-cell and hybrid-cell stent groups. Results : The study included 234 patients comprising 146 patients with a closed-cell stent (Xact stent, Abbott Vascular (mean age: 68.5 ±8.6; 67.1% male and 88 patients with a hybrid-cell stent (Cristallo Ideale, Medtronic (mean age: 67.2 ±12.8; 68.2% male. There was no significant difference between the groups with respect to periprocedural or 30-day adverse event rates. While there was no difference in terms of tortuosity index between the groups, there was a higher procedural ICA vasospasm rate in the closed-cell stent group (35 patients, 23% compared with the hybrid-cell stent group (10 patients, 11% (p = 0.017. Conclusions : The results of this study showed no significant difference in the clinical adverse event rates after CAS between the closed-cell stent group and the hybrid-cell stent group. However, procedural ICA vasospasm was more common in the closed-cell stent group.

  16. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    BACKGROUND: In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery...... disease who were receiving routine clinical care with no direct follow-up. METHODS: We did a single-blind, all-comer superiority trial in adult patients with chronic stable coronary artery disease or acute coronary syndromes, and at least one target lesion. Patients were treated at one of five...... Danish administrative and health-care registries. The primary endpoint was a composite of major adverse cardiac events within 9 months: cardiac death, myocardial infarction, and target vessel revascularisation. Intention-to-treat analyses were done at 9-month and 18-month follow-up. This trial...

  17. Análisis Costo Efectividad del Stent Farmacológico V/S Stent no Farmacológico en Cardiopatía Isquémica en Chile.

    Science.gov (United States)

    De la Puente, Catherine; Vallejos, Carlos; Velásquez, Mónica; Soto, David; Orellana, Juan

    2012-12-01

    To evaluate and compare the costs and effectiveness of two alternative stent, drug eluting stent (SF) and bare metal stent (SNF). Cost-utility analysis based on a Markov model using data from a cohort study of Hospital Las Higueras of Talcahuano, Chile. The effectiveness measure was the rate of restenosis and the time of restenosis. The effectiveness outcomes are expressed in quality-adjusted life years (QALY) gained. Costs are expressed in national currency 2011. The evaluation perspective was from the public heath budget. We model a cohort from age 63 to 80 years, life expectancy in Chile. Apply discount rate of 0, 3% and 6% for results and costs. Sensitivity analysis is performed according to the ranges of variability in costs, the utility values of the variables and transition between states. No differences in restenosis rates between the two stents, although there were differences in the time of restenosis. The incremental cost effectiveness ratio (ICER) no discount rate was CH$ 235.749 per QALY gained when using drug-eluting stent, the value below the equivalent of 1 Gross Domestic Product (PIB) per capita for 2011 in Chile. The drug-eluting stent (SF) is cost effective compared to bare metal stent (SNF). The ICER is not affected by the sensitivity analysis (variability of cost, utility ranges used, probability of restenosis). Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  18. Iliac artery stenting in patients with poor distal runoff: Influence of concomitant infrainguinal arterial reconstruction.

    Science.gov (United States)

    Timaran, Carlos H; Ohki, Takao; Gargiulo, Nicholas J; Veith, Frank J; Stevens, Scott L; Freeman, Michael B; Goldman, Mitchell H

    2003-09-01

    Inadequate infrainguinal runoff is considered an important risk factor for iliac stent failure. However, the influence of concomitant infrainguinal arterial reconstruction (CIAR) on iliac stent patency is unknown. This study evaluated the influence of CIAR on outcome of iliac angioplasty and stenting (IAS) in patients with poor distal runoff. Over 5 years (1996 to 2001), 68 IAS procedures (78 stents) were performed in 62 patients with poor distal runoff (angiographic runoff score >or=5). The SVS/AAVS reporting standards were followed to define outcome variables and risk factors. Data were analyzed with both univariate analysis (Kaplan-Meier method [K-M]) and regression analysis (Cox proportional hazards model). Indications for iliac artery stenting were disabling claudication (59%) and limb salvage (41%). Of the 68 procedures, IAS with CIAR was performed in 31 patients (46%), and IAS alone was performed in 37 patients (54%). Patients undergoing IAS with CIAR were older (P =.03) and had more extensive and multifocal iliac artery occlusive disease, with more TASC (TransAtlantic Inter-Society Consensus) type C lesions (P =.03), compared with patients undergoing IAS alone. No other significant differences in risk factors were noted. Runoff scores between patients undergoing IAS with CIAR and those undergoing IAS alone were not significantly different (median runoff scores, 6 [range, 5-8] and 7 [range, 5-9], respectively; P =.77). Primary stent patency rate at 1, 3, and 5 years was 87%, 54%, and 42%, respectively, for patients undergoing IAS with CIAR, and was 76%, 66%, and 55%, respectively, for patients undergoing IAS. Univariate analysis revealed that primary stent patency rate was not significantly different between the 2 groups (K-M, log-rank test, P =.81). Primary graft patency rate for CIAR was 81%, 52%, and 46% at 1, 3, and 5 years, respectively. Performing CIAR did not affect primary iliac stent patency (relative risk, 1.1; 95% confidence interval, 0.49-2.47; P

  19. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  20. Drug-eluting versus bare-metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kaiser, Christoph; Galatius, Soeren; Erne, Paul

    2010-01-01

    Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...

  1. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

    International Nuclear Information System (INIS)

    Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko

    2008-01-01

    We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

  2. Real-Time Electrical Bioimpedance Characterization of Neointimal Tissue for Stent Applications

    Directory of Open Access Journals (Sweden)

    David Rivas-Marchena

    2017-07-01

    Full Text Available To follow up the restenosis in arteries stented during an angioplasty is an important current clinical problem. A new approach to monitor the growth of neointimal tissue inside the stent is proposed on the basis of electrical impedance spectroscopy (EIS sensors and the oscillation-based test (OBT circuit technique. A mathematical model was developed to analytically describe the histological composition of the neointima, employing its conductivity and permittivity data. The bioimpedance model was validated against a finite element analysis (FEA using COMSOL Multiphysics software. A satisfactory correlation between the analytical model and FEA simulation was achieved in most cases, detecting some deviations introduced by the thin “double layer” that separates the neointima and the blood. It is hereby shown how to apply conformal transformations to obtain bioimpedance electrical models for stack-layered tissues over coplanar electrodes. Particularly, this can be applied to characterize the neointima in real-time. This technique is either suitable as a main mechanism for restenosis follow-up or it can be combined with proposed intelligent stents for blood pressure measurements to auto-calibrate the sensibility loss caused by the adherence of the tissue on the micro-electro-mechanical sensors (MEMSs.

  3. Efficacy of percutaneous transluminal renal angioplasty with stent in elderly male patients with atherosclerotic renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhao J

    2012-10-01

    Full Text Available Jiahui Zhao, Qingli Cheng, Xiaoying Zhang, Meihua Li, Sheng Liu, Xiaodan WangDepartment of Geriatric Nephrology, Chinese PLA General Hospital, Beijing, ChinaObjectives: Percutaneous transluminal renal angioplasty with stent implantation (PTRAS has become the treatment of choice for atherosclerotic renal artery stenosis (ARAS. This study evaluates the long-term effects of PTRAS on hypertension and renal function in elderly patients with ARAS.Methods: We conducted a retrospective cohort study of all patients who underwent PTRAS in the geriatric division of a tertiary medical center during the period 2003–2010. The clinical data were extracted from the medical records of each patient. Changes in blood pressure, antihypertensive treatment, and estimated glomerular filtration rate were analyzed before and after PTRAS.Results: Eighty-six stents in 81 elderly patients were placed successfully. The average age of the patients was 76.2 years (65–89 years. Mean follow-up was 31.3 months (range 12 –49 months. There was a significant decrease in both systolic and diastolic blood pressure at the third day after the PTRAS procedure and the reduction in blood pressure was constant throughout the follow-up period until 36 months after PTRAS. However, there was no marked benefit to renal function outcome during the follow-up period. The incidence of contrast-induced nephropathy was 9.9% in this study group. The rate of renal artery restenosis was 14.8%. The survival rate was 96.3% for 4 years after the procedure.Conclusion: It is beneficial to control blood pressure in elderly patients with ARAS up to 36 months after a PTRAS procedure. However, their renal function improvement is limited.Keywords: angioplasty, hypertension, renal function, elderly, renal artery stenosis

  4. Late effects of low-energy gamma-emitting stents in a rabbit iliac artery model

    International Nuclear Information System (INIS)

    Strauss, Bradley H.; Li, Chris; Whittingham, Heather A.; Tio, Fermin O.; Kutryk, Michael J.B.; Janicki, Christian; Sparkes, John D.; Turnlund, Todd; Sweet, William L.

    2002-01-01

    Purpose: To determine the long-term dose response of novel low-dose γ-emitting stents in a rabbit iliac artery model. Methods and Materials: Control stents (n=24) and 103 Pd stents 1.0 to 4.0 mCi (n=36) were implanted in the iliac arteries of 30 New Zealand rabbits. Stents were evaluated by intravascular ultrasound (immediately post procedure and before killing) and by histomorphometry. Results: At 26 weeks, 28 rabbits were killed, with no evidence of stent thrombosis. In the body of the stent there was a dose-response relationship with 50% inhibition of intimal hyperplasia at the highest activity compared to control stents (p=0.07) and a significant increase in intimal hyperplasia at the lowest activity (p 103 Pd stents is feasible with reduction of in-stent hyperplasia in a dose-related manner. However, significant narrowing at the stent edges, increased in-stent hyperplasia at lower activities, and incomplete vascular healing with persistence of immature neointima at higher activities are significant limitations

  5. Recruitable collateral blood flow index predicts coronary instent restenosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Lassen, Jens Flensted

    2007-01-01

    AIMS: Collateral flow may influence long-term results after percutaneous coronary intervention (PCI) because of haemodynamic forces compete with the antegrade flow through the dilated lesion. The aim of the study was to assess the influence of recruitable collateral blood flow on restenosis...... in patients undergoing PCI with bare metal stents and using optimal antithrombotic treatment. METHODS AND RESULTS: In 95 patients, 95 de novo lesions were treated with PCI and a bare metal stent. Fractional flow reserve (FFR) at maximum hyperaemia induced by intravenous adenosine was determined. The pressure.......02-1.12, P = 0.016). CONCLUSION: Recruitable collateral blood flow measured during balloon inflation predicts angiographic instent restenosis in PCI patients treated with bare metal stents. Udgivelsesdato: 2007-Aug...

  6. Intravascular local gene transfer mediated by protein-coated metallic stent.

    Science.gov (United States)

    Yuan, J; Gao, R; Shi, R; Song, L; Tang, J; Li, Y; Tang, C; Meng, L; Yuan, W; Chen, Z

    2001-10-01

    To assess the feasibility, efficiency and selectivity of adenovirus-mediated gene transfer to local arterial wall by protein-coated metallic stent. A replication-defective recombinant adenovirus carrying the Lac Z reporter gene for nuclear-specific beta-galactosidase (Ad-beta gal) was used in this study. The coating for metallic stent was made by immersing it in a gelatin solution containing crosslinker. The coated stents were mounted on a 4.0 or 3.0 mm percutaneous transluminal coronary angioplasty (PTCA) balloon and submersed into a high-titer Ad-beta gal viral stock (2 x 10(10) pfu/ml) for 3 min, and then implanted into the carotid arteries in 4 mini-swines and into the left anterior descending branch of the coronary artery in 2 mini-swines via 8F large lumen guiding catheters. The animals were sacrificed 7 (n = 4), 14 (n = 1) and 21 (n = 1) days after implantation, respectively. The beta-galactosidase expression was assessed by X-gal staining. The results showed that the expression of transgene was detected in all animal. In 1 of carotid artery with an intact intima, the beta-gal expression was limited to endothelial cells. In vessels with denuded endothelium, gene expression was found in the sub-intima, media and adventitia. The transfection efficiency of medial smooth muscle cells was 38.6%. In 2 animals sacrificed 7 days after transfection, a microscopic examination of X-gal-stained samples did not show evidence of transfection in remote organs and arterial segments adjacent to the treated arterial site. Adenovirus-mediated arterial gene transfer to endothelial, smooth muscle cells and adventitia by protein-coated metallic stent is feasible. The transfection efficiency is higher. The coated stent may act as a good carrier of adenovirus-mediated gene transfer and have a potential to prevent restenosis following PTCA.

  7. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    Science.gov (United States)

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  8. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  9. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S

    2009-01-01

    Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston......-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2...

  10. Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

    Science.gov (United States)

    de Jaegere, P; Mudra, H; Figulla, H; Almagor, Y; Doucet, S; Penn, I; Colombo, A; Hamm, C; Bartorelli, A; Rothman, M; Nobuyoshi, M; Yamaguchi, T; Voudris, V; DiMario, C; Makovski, S; Hausmann, D; Rowe, S; Rabinovich, S; Sunamura, M; van Es, G A

    1998-08-01

    A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. The study was designed to be multicentred, prospective, and observational. One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8

  11. Treatment of splenic artery aneurysm with double overlapping bare stents: case report

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Han, Young Min; Jin, Gong Yong

    2004-01-01

    The traditional treatment of splenic artery aneurysm (SAA) is generally surgery and/or transcatheter arterial embolization, but recently, the treatment of SAA using a stent graft has been reported. However, the acute angle of the celiac axis, as well as the tortuous path of the splenic artery makes the use of stent graft difficult for treatment of aneurysma. We report here a case of SAA treated with the technique of double overlapping metallic stents

  12. Successful percutaneous stenting of a right gastroepiploic coronary bypass graft using monorail delivery system: a case report.

    Science.gov (United States)

    Alam, M; Safi, A M; Mandawat, M K; Anderson, J E; Kwan, T; Feit, A; Clark, L T

    2000-02-01

    The right gastroepiploic artery (RGEA) is being successfully used as an arterial conduit in a selected group of patients undergoing coronary artery bypass graft surgery. However, myocardial ischemia may result due to spasm, occlusion, and stenosis of this graft. The anastamosis site at distal right coronary artery (RCA) or posterior descending artery (PDA) is the most common location for stenosis of an in situ gastroepiploic coronary bypass graft. Balloon angioplasty of such stenoses has been reported with optimal short-term results. Stent deployment would decrease the restenosis rate, so that repeat procedures could be minimized for these technically challenging lesions. We describe a case of successful deployment of a stent with monorail delivery system at the anastamotic site stenosis of an in situ gastroepiploic right coronary artery bypass graft. This percutaneous coronary intervention could prevent redo coronary artery bypass graft surgery. Cathet. Cardiovasc. Intervent. 49:197-199, 2000. Copyright 2000 Wiley-Liss, Inc.

  13. In-Vitro Evaluation of Coronary Stents and 64-Detector-Row Computed Tomography Using a Newly Developed Model of Coronary Artery Stenosis

    International Nuclear Information System (INIS)

    Schlosser, T.; Scheuermann, T.; Ulzheimer, S.; Mohrs, O.K.; Kuehling, M.; Al brecht, P.E.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2008-01-01

    Background: Stent implantation is the predominant therapy for non-surgical myocardial revascularization in patients with coronary artery disease. However, despite substantial advances in multidetector computed tomography (MDCT) coronary imaging, a reliable detection of coronary in-stent restenosis is currently not possible. Purpose: To examine the ability of 64-detector-row CT to detect and to grade in-stent stenosis in coronary stents using a newly developed ex-vivo vessel phantom with a realistic CT density pattern, artificial stenosis, and a thorax phantom. Material and Methods: Four different stents (Liberte and Lunar ROX, Boston Scientific; Driver, Medtronic; Multi-Link Vision, Guidant) were examined. The stents were placed on a polymer tube with a diameter of 2.5, 3.0, 3.5, or 4.0 mm. Different degrees of stenosis (0%, 30%, 50%, 70-80%) were created inside the tube. For quantitative analysis, attenuation values were measured in the non-stenotic vessel outside the stent, in the non-stenotic vessel inside the stent, and in the stenotic area inside the stent. The grade of stenosis was visually assessed by two observers. Results: All stents led to artificial reduction of attenuation, the least degree of which was found in the Liberte stent (11.3±10.2 HU) and the Multi-Link Vision stent (17.6±17.9 HU; P 0.25). Overall, the non-stenotic vessel was correctly diagnosed in 55.5%, the low-grade stenosis in 58.3%, the intermediate stenosis in 63.8%, and the high-grade stenosis in 80.5%. In the 3.0-, 3.5-, and 4.0-mm vessels, in none of the cases was a non-stenotic or low-grade stenotic vessel misdiagnosed as intermediate or high-grade stenosis. The average deviation from the real grade of stenosis was 0.40 for the Liberte stent, 0.46 for the Lunar ROX stent, 0.45 for the Driver stent, and 0.58 for the Multi-Link Vision stent. Conclusion: Our ex-vivo data show that non-stenotic stents and low-grade in-stent stenosis can be reliably differentiated from intermediate and

  14. Study on the effect of location of intracranial arterial stenosis on the safety of stenting

    Directory of Open Access Journals (Sweden)

    Yu-jie SUN

    2017-11-01

    Full Text Available Objective To investigate the effect of location of intracranial arterial stenosis on the safety of intracranial stenting. Methods A total of 73 patients with symptomatic intracranial atherosclerotic stenosis (ICAS were divided into intracranial internal carotid artery (IICA, N = 18, middle cerebral artery (MCA-M1 segment (MCA-M1, N = 11, intracranial vertebral artery (IVA, N = 27 and basilar artery (BA, N = 17. All of them underwent intracranial stenting. The improvement of intracranial arterial stenosis, cerebrovascular complications including perforating events, artery dissection, in-stent thrombosis, distal stent arterial embolism and cerebral hyperperfusion, and neurological complications including transient ischemic attack (TIA, ischemic stroke and intracranial hemorrhage were recorded. Modified Rankin Scale (mRS was used to evaluate the prognosis 30 d after operation. Results A total of 73 stents were implanted in 73 patients (35 Apollo balloon-expandable stents and 38 Wingspan self-expandable stents. Among them, 10 cases (10/18 were treated with Apollo stents and 8 cases (8/18 with Wingspan stents in IICA group, 5 cases (5/11 were treated with Apollo stents and 6 cases (6/11 with Wingspan stents in MCA-M1 group, 16 cases (59.26%, 16/27 were treated with Apollo stents and 11 cases (40.74%, 11/27 with Wingspan stents in IVA group, and 4 cases (4/17 were treated with Apollo stents and 13 cases (13/17 with Wingspan stents in BA group. No significant difference was seen in stent type among 4 groups (χ2 = 7.422, P = 0.201. The stenosis rate of IICA group after treatment [(10.94 ± 1.99%] was significantly improved than before treatment [(90.89 ± 7.71%; t = 69.545, P = 0.000]. The stenosis rate of MCA-M1 group after treatment [(10.37 ± 2.14%] was significantly improved than before treatment [(87.64 ± 9.46%; t = 26.000, P = 0.000]. The stenosis rate of IVA group after treatment [(11.02 ± 1.99% ] was significantly improved than before

  15. Usefulness of CT angiography after metallic stent implantation of the internal carotid artery

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyeon Chul; Kim, Jae Kyu; Seo, Jeong Jin; Jeong, Gwang Woo; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of CT angiography in patients with implantation of metallic stent for stenosed internal carotid artery. Seven patients with atherosclerotic stenosis of the internal carotid artery underwent metallic stent implantation. All were male and their ages ranged from 36 to 69 years. A total of seven stents were placed in the internal carotid artery in five patients and in the carotid bifurcation in two. Spiral CT scans were obtained and CT angiographic images were reconstructed using MPR or curved MPR techniques at a workstation. The interval between CT and conventional angiography did not exceed six days except in one patient, in whom it was 61days. CT and conventional angiography were compared for stent position with respect to the carotid bifurcation, stent deformation, intraluminal filling defect, and luminal caliber and outflow. Luminal patency of the implanted stent was measured according to NASCET(North American Symptomatic Carotid Endarterectomy Trial) criteria, and statistically processed (p>.05). The presence or absence of intrastent thrombus and vascular wall calcification was determined using axial source images. In all patients, CT angiographic findings matched those obtained by conventional angiography. Complications such as migration or deformation of an implanted stent, intraluminal filling defect, change of luminal caliber or outflow of implanted stent were not observed in any patient. In two studies in which Wilcoxon signed rank test was used, degree of stent expansion correlated closely(p=0.237). Axial source images showed that in no patient was an intrastent thrombus present, though in five, vascular wall calcification of internal carotid arteries outside the stent was noted. CT angiography is useful for the assessment of positional change, occlusion, and luminal patency of a stent-implanted internal carotid artery

  16. Enterprise stent for the treatment of symptomatic intracranial atherosclerotic stenosis: an initial experience of 44 patients.

    Science.gov (United States)

    Feng, Zhengzhe; Duan, Guoli; Zhang, Ping; Chen, Lei; Xu, Yi; Hong, Bo; Zhao, Wenyuan; Liu, Jianmin; Huang, Qinghai

    2015-10-08

    Wingspan stenting for the treatment of complex intracranial atherosclerotic stenosis (ICAS), i.e., that involving tortuous vascular pathways, long (>15 mm) lesions or arterial bifurcations, has a relatively high risk of complications. This retrospective study assessed the safety and efficacy of undersized balloon angioplasty followed by deployment of the more flexible Enterprise stent for the treatment of complex symptomatic ICAS. Forty-four patients on combined antiplatelet therapy and intensive risk factor management and a symptomatic 70-99% stenosis of a major intracranial artery in complex settings that was treated with balloon angioplasty and Enterprise stent deployment between July 2009 and August 2013 were enrolled. Primary outcome was occurrence of ischemic or hemorrhagic stroke or death within 30 days after intervention. Secondary outcomes included procedural success (defined as achievement of 50% in-stent restenosis after mean 22 months follow-up. In this retrospective, single-center experience, undersized balloon angioplasty followed by Enterprise stent deployment appears technically feasible with a relatively low rate of complications for the treatment of complex symptomatic ICAS. Prospective, multicenter, randomized controlled trials against optimal medical management are warranted.

  17. Development and characterization of a coronary polylactic acid stent prototype generated by selective laser melting.

    Science.gov (United States)

    Flege, Christian; Vogt, Felix; Höges, Simon; Jauer, Lucas; Borinski, Mauricio; Schulte, Vera A; Hoffmann, Rainer; Poprawe, Reinhart; Meiners, Wilhelm; Jobmann, Monika; Wissenbach, Konrad; Blindt, Rüdiger

    2013-01-01

    In-stent restenosis is still an important issue and stent thrombosis is an unresolved risk after coronary intervention. Biodegradable stents would provide initial scaffolding of the stenosed segment and disappear subsequently. The additive manufacturing technology Selective Laser Melting (SLM) enables rapid, parallel, and raw material saving generation of complex 3- dimensional structures with extensive geometric freedom and is currently in use in orthopedic or dental applications. Here, SLM process parameters were adapted for poly-L-lactid acid (PLLA) and PLLA-co-poly-ε-caprolactone (PCL) powders to generate degradable coronary stent prototypes. Biocompatibility of both polymers was evidenced by assessment of cell morphology and of metabolic and adhesive activity at direct and indirect contact with human coronary artery smooth muscle cells, umbilical vein endothelial cells, and endothelial progenitor cells. γ-sterilization was demonstrated to guarantee safety of SLM-processed parts. From PLLA and PCL, stent prototypes were successfully generated and post-processing by spray- and dip-coating proved to thoroughly smoothen stent surfaces. In conclusion, for the first time, biodegradable polymers and the SLM technique were combined for the manufacturing of customized biodegradable coronary artery stent prototypes. SLM is advocated for the development of biodegradable coronary PLLA and PCL stents, potentially optimized for future bifurcation applications.

  18. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting.

    Science.gov (United States)

    Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi

    2016-01-01

    When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  19. The sirolimus-eluting Cypher Select coronary stent for the treatment of bare-metal and drug-eluting stent restenosis: insights from the e-SELECT (Multicenter Post-Market Surveillance) registry.

    Science.gov (United States)

    Abizaid, Alexandre; Costa, J Ribamar; Banning, Adrian; Bartorelli, Antonio L; Dzavik, Vladimir; Ellis, Stephen; Gao, Runlin; Holmes, David R; Jeong, Muyng Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Orlick, Amy; Spaulding, Christian; Worthley, Stephen; Urban, Philip M

    2012-01-01

    This study sought to compare the 1-year safety and efficacy of Cypher Select or Cypher Select Plus (Cordis Corporation, Bridgewater, New Jersey) sirolimus-eluting stents (SES) with the treatment of bare-metal stents (BMS) and drug-eluting stent (DES) in-stent restenosis (ISR) in nonselected, real-world patients. There is paucity of consistent data on DES for the treatment of ISR, especially, DES ISR. The e-SELECT (Multicenter Post-Market Surveillance) registry is a Web-based, multicenter and international registry encompassing virtually all subsets of patients and lesions treated with at least 1 SES during the period from 2006 to 2008. We enrolled in this pre-specified subanalysis all patients with at least 1 clinically relevant BMS or DES ISR treated with SES. Primary endpoint was major adverse cardiac events and stent thrombosis rate at 1 year. Of 15,147 patients enrolled, 1,590 (10.5%) presented at least 1 ISR (BMS group, n = 1,235, DES group, n = 355). Patients with DES ISR had higher incidence of diabetes (39.4% vs. 26.9%, p target lesion revascularization and definite/probable late stent thrombosis were higher in patients with DES ISR (6.9% vs. 3.1%, p = 0.003, and 1.8% vs. 0.5%, p = 0.04, respectively). Use of SES for either BMS or DES ISR treatment is safe and associated with low target lesion revascularization recurrence and no apparent safety concern. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Evaluation of the restenosis of coronary artery after percutaneous transluminal coronary angioplasty by three-dimensional coronary magnetic resonance angiography

    International Nuclear Information System (INIS)

    Arisaka, Hiraku

    2000-01-01

    Coronary magnetic resonance angiography (MRA) has been recently brought into clinical use, however, there has not been reports on the comparison with MRA and conventional contrast coronary angiography (CAG) in the detection of the localization and characteristics of coronary restenosis after percutaneous transluminal coronary angioplasty (PTCA). To assess the restenosis of coronary artery after PTCA, this study compared three-dimensional (3D) coronary MRA and CAG. One hundred three patients (76 males and 27 females, average age of 64.6±9.3 years old) were performed coronary MRA at 3-6 months after PTCA. The right coronary artery (RCA) group consist of 21 patients, the left anterior descending branch (LAD) 63 patients and the left circumflex branch (LCX) 19 patients. Coronary MRA was performed with the patients in supine position on a 1.5 T whole body scanner (MAGNETOM VISION, Siemens AG, Germany) using body array coil. The imaging technique used a 3-D gradient echo sequence with respiratory gating and fat suppression. The slice thickness was 2 mm, slab thickness 32 mm, a field of view of 300 mm and a matrix of 128 x 256. Other parameters were an echo time of 2.7 ms and a repetition time of 600 to 1100 msec. The measurement time of 1 imaging slab took 15 to 20 minutes depending on the patient's heart rate. The coronary arteries were reconstructed from the 3-D data set using a multiplanar reconstruction (MPR) technique. According to previous coronary MRA studies, a significant stenosis with a luminal reduction of ≥50% was assumed if a marked signal reduction or signal loss of a vessel segment was visible. In CAG, 57 of 103 patients showed restenosis. In coronary MRA, 37 of 103 patients demonstrated restenosis. The sensitivity, specificity, positive and negative predictive values were 64.9%, 100%, 100% and 69.6%, respectively. Predictive accuracy was 79.6%. Three-dimensional coronary MRA is useful in a noninvasive diagnostic method to evaluate the coronary

  1. Models and Analysis of Atherosclerosis, Restenosis, and Aneurysm Formation in the Mouse

    NARCIS (Netherlands)

    de Waard, Vivian; Gijbels, Marion J. J.; Lutgens, Esther; de Winther, Menno P. J.; de Vries, Carlie J. M.

    2012-01-01

    Atherosclerosis is considered a chronic inflammatory condition of the vessel wall and involves a high chronic concentration of low-density lipoprotein (LDL) in blood. In humans, restenosis develops after intravascular interventions such as angioplasty and stent placement to treat atherosclerosis,

  2. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  3. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  4. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  5. Enterprise stent for waffle-cone stent-assisted coil embolization of large wide-necked arterial bifurcation aneurysms.

    Science.gov (United States)

    Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M

    2013-01-01

    Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.

  6. Biodegradable magnesium-alloy stent:current situation in research

    International Nuclear Information System (INIS)

    Chen Hua; Zhao Xianxian

    2011-01-01

    In recent years, permanent metal stents are employed in the majority of interventional therapies; nevertheless, such kind of stents carries the problems of thrombosis and restenosis. Therefore, the biodegradable magnesium alloy stent has become the focus of attention. Theoretically, it has overcome the problems caused by permanent metal stents, so it is the development direction to use the biodegradable magnesium alloy in future. The authors believe that biodegradable magnesium alloy stents will be widely used in interventional procedures for many diseases. (authors)

  7. Use of a wire extender during neuroprotected vertebral artery angioplasty and stenting.

    Science.gov (United States)

    Lesley, Walter S; Kumar, Ravi; Rangaswamy, Rajesh

    2010-09-01

    The off-label use of an extender wire during vertebral artery stenting and angioplasty with or with neuroprotection has not been previously reported. Retrospective, single-patient, technical report. After monorail balloon angioplasty was performed on a proximal left vertebral artery stenosis, the 190 cm long Accunet neuroprotection filter device was not long enough for delivery of an over-the-wire stent. After mating a 145 cm long, 0.014 inch extension wire to the filter device, a balloon-mounted Liberté stent was implanted with good angiographic and clinical results. The off-label use of an extender wire permits successful over-the-wire stenting on a monorail neuroprotection device for vertebral artery endosurgery.

  8. Kissing stenting of aorto-ostial lesions in juxtaposed renal arteries

    OpenAIRE

    Hasija, Pradeep; Chadha, Davinder; Kalra, Ravi

    2014-01-01

    Percutaneous angioplasty with or without stenting has become an established procedure for treatment of renal artery stenosis for control of hypertension or progressive renal dysfunction. Anatomic variation of renal arteries is common with dual blood supply of unilateral kidney noted in almost 25% of the general population. Renal angioplasty of these anatomic variants of renal arteries is challenging. We present an unusual case of juxtaposed renal arteries with aorto-ostial lesion where direct...

  9. Magnetizable stent-grafts enable endothelial cell capture

    Science.gov (United States)

    Tefft, Brandon J.; Uthamaraj, Susheil; Harburn, J. Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

  10. Acute hemifacial ischemia as a late complication of carotid stenting

    Directory of Open Access Journals (Sweden)

    Maurizio Domanin, MD

    2017-06-01

    Full Text Available Concerns about carotid artery stenting (CAS center primarily on procedural complications like acute occlusion, stroke, and long-term intrastent restenosis. External carotid artery (ECA thrombosis is observed during CAS follow-up, but it often remains asymptomatic or, at worst, results in jaw claudication. We report here a case of late occlusion of the ECA after CAS with symptoms of acute homolateral facial ischemia as well as pain, cyanosis, tongue numbness, and skin coldness. The patient was submitted to local thrombolysis and balloon angioplasty with regression of symptoms after recanalization. With this report, we add a caveat about blockage of the ECA ostium during CAS.

  11. High-dose external beam irradiation inhibits neointima formation in stented pig coronary arteries

    International Nuclear Information System (INIS)

    Verheye, Stefan; Coussement, Patrick K.; Salame, Mahomed Y.; Fallahi, Payam; Cui Jianhua; Chronos, Nicolas A.F.; King, Spencer B.; Crocker, Ian R.; Robinson, Keith A.

    2001-01-01

    Purpose: To evaluate high-dose external beam irradiation (EBRT) in a pig coronary stent preparation because low and intermediate-dose EBRT failed to show inhibition of neointima formation in stented animal models. Methods and Materials: Thirty-five stents were implanted in the coronary arteries of 17 pigs. Seven pigs were exposed to a single dose of 21 Gy EBRT immediately after stenting. Ten stented, nonirradiated pigs served as controls. After 4 weeks, the study arteries and myocardium were examined by light and scanning electron microscopy. Results: Compared with controls, 21 Gy EBRT resulted in a larger lumen area (7.57±1.67 mm 2 vs. 4.00±1.63 mm 2 , p 2 vs. 3.36±2.26 mm 2 , p<0.001) and a smaller maximal intimal thickness (0.16±0.09 mm vs. 0.68±0.31 mm, p<0.001). Unresorbed intramural hemorrhages and adherent mural thrombi were present in the irradiated vessels, which also showed incomplete re-endothelialization. The irradiated hearts demonstrated diffuse interstitial and perivascular inflammation and fibrosis. Conclusions: EBRT at 21 Gy to the entire heart significantly inhibited neointima formation in stented pig coronary arteries but also resulted in incomplete re-endothelialization, myocardial inflammation, and fibrosis. Improvements in localization and delivery techniques are required to allow clinical implementation of this technique

  12. Impact on outcome of different types of carotid stent: results from the European Registry of Carotid Artery Stenting.

    Science.gov (United States)

    Stabile, Eugenio; Giugliano, Giuseppe; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitrios; Sannino, Anna; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Rubino, Paolo; Esposito, Giovanni; Tesorio, Tullio

    2016-06-12

    Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk.

  13. Use of drug-eluting stents in Victorian public hospitals.

    Science.gov (United States)

    Yan, Bryan P; Ajani, Andrew E; Duffy, Stephen J; New, Gishel; Horrigan, Mark; Szto, Gregory; Walton, Antony; Eccleston, David; Lefkovits, Jeffery; Black, Alexander; Sebastian, Martin; Brennan, Angela L; Reid, Christopher M; Clark, David J

    2006-10-02

    We aimed to assess the pattern of use of drug-eluting stents (DESs) in patients undergoing percutaneous coronary interventions (PCIs) in Victorian public hospitals. Prospective study comparing the use of one or more DESs versus bare-metal stents (BMSs) only, in consecutive patients undergoing 2428 PCIs with stent implantation from 1 April 2004 to 31 December 2005 at seven Victorian public hospitals. Adherence to current Victorian Department of Human Services guidelines which recommend DES use in patients with high-risk features for restenosis (diabetes, small vessels, long lesions, in-stent restenotic lesions, chronic total occlusions and bifurcation lesions). Of the 2428 PCIs performed, at least one DES was implanted in 1101 (45.3%) and BMSs only were implanted in 1327 (54.7%). In 87.7% (966/1101) of PCI with DESs, there was at least one criterion for high risk of restenosis. DESs were more likely to be used in patients with diabetes (risk ratio [RR], 2.45; 95% CI, 2.02-2.97), small vessels (RR, 3.35; 95%CI, 2.35-4.76), long lesions (RR, 3.87; 95% CI, 3.23-4.65), in-stent restenotic lesions (RR, 3.98; 95%CI, 2.67-6.06), chronic total occlusions (RR, 1.30; 95% CI, 0.51-2.88) and bifurcation lesions (RR, 2.23; 95%CI, 1.57-3.17). However, 66.2% (1608/2428) of all PCIs were in patients eligible for DESs according to Victorian guidelines, and in 39.9% (642/1608) of these PCIs, a BMS was used. In Victorian public hospitals, DESs have been largely reserved for patients at high risk of restenosis in accordance with Department of Human Services guidelines. However, many patients with high-risk criteria for restenosis did not receive DESs. Greater use of DESs in these patients may improve outcomes by reducing the need for repeat revascularisation.

  14. Functional effects of renal artery stent placement on treated and contralateral kidneys.

    NARCIS (Netherlands)

    Leertouwer, T.C.; Derkx, F.H.M.; Pattynama, P.M.; Deinum, J.; Dijk, L.C. van; Schalekamp, M.A.D.H.

    2002-01-01

    BACKGROUND: This study examined the effects of stent placement for renal artery stenosis on the function of treated and contralateral kidneys. METHODS: Eighteen patients who underwent stent placement for unilateral renal artery stenosis presenting with hypertension and/or renal failure were studied

  15. Feasibility and Safety of Transradial Arterial Approach for Simultaneous Right and Left Vertebral Artery Angiographic Studies and Stenting

    International Nuclear Information System (INIS)

    Yip, H.-K.; Youssef, Ali A.; Chang, W.-N.; Lu, C.-H.; Yang, C.-H.; Chen, S.-M.; Wu, C.-J.

    2007-01-01

    Objectives. This study investigated whether the transradial artery (TRA) approach using a 6-French (F) Kimny guiding catheter for right vertebral artery (VA) angiographic study and stenting is safe and effective for patients with significant VA stenosis. Background. The TRA approach is commonly performed worldwide for both diagnostic cardiac catheterization and catheter-based coronary intervention. However, to our knowledge, the safety and feasibility of left and right VA angiographic study and stenting, in the same procedure, using the TRA approach for patients with brain ischemia have not been reported. Methods. The study included 24 consecutive patients (22 male, 2 female; age, 63-78 years). Indications for VA angiographic study and stenting were (1) prior stroke or symptoms related to vertebrobasilar ischemia and (2) an asymptomatic but vertebral angiographic finding of severe stenosis (>70%). A combination of the ipsilateral and retrograde-engagement technique, which involved a looping 6-F Kimny guiding catheter, was utilized for VA angiographic study. For VA stenting, an ipsilateral TRA approach with either a Kimny guiding catheter or a left internal mammary artery guiding catheter was utilized in 22 patients and retrograde-engagement technique in 2 patients. Results. A technically successful procedure was achieved in all patients, including left VA stenting in 15 patients and right VA stenting in 9 patients. The mean time for stenting (from engagement to stent deployment) was 12.7 min. There were no vascular complications or mortality. However, one patient suffered from a transient ischemic attack that resolved within 3 h. Conclusion. We conclude that TRA access for both VA angiographic study and VA stenting is safe and effective, and provides a simple and useful clinical tool for patients unsuited for femoral arterial access

  16. Intravascular stenting in the superior mesenteric artery for chronic abdominal angina.

    Science.gov (United States)

    Busquet, J

    1997-11-01

    Abdominal angina is an early clinical expression of occlusive mesenteric arterial insufficiency, a condition that requires aggressive treatment to prevent intestinal infarction. We report a case of chronic mesenteric ischemia in a young polyvascular man who had symptoms of abdominal angina. An aortic angiogram revealed a significant ostial stenosis of the superior mesenteric artery (SMA) associated with an occlusion of the inferior mesenteric artery. After predilation of the ostial portion of the SMA, significant residual stenosis remained. A balloon-expandable Palmaz P154 stent was deployed, restoring adequate luminal dimensions and blood flow. The patient was discharged after 2 days and remains asymptomatic at 5 months. Intraluminal stenting for treatment of mesenteric ischemia represents a viable alternative to surgical revascularization in selected cases.

  17. Differences in optical coherence tomographic findings and clinical outcomes between excimer laser and cutting balloon angioplasty for focal in-stent restenosis lesions.

    Science.gov (United States)

    Nishino, Masami; Lee, Yasuharu; Nakamura, Daisuke; Yoshimura, Takahiro; Taniike, Masayuki; Makino, Nobuhiko; Kato, Hiroyasu; Egami, Yasuyuki; Shutta, Ryu; Tanouchi, Jun; Yamada, Yoshio

    2012-10-01

    In-stent restenosis (ISR), especially focal ISR, after percutaneous coronary intervention (PCI) remains one of the major clinical problems in the drug-eluting stent (DES) era. Several reports have revealed that excimer laser coronary angioplasty (ELCA) is useful for ISR; however, detailed findings after ELCA are unknown. Therefore, we investigated the condition of the neointima after ELCA for ISR with optical coherence tomography (OCT) and compared the OCT findings and clinical outcome between ELCA and cutting-balloon angioplasty (CBA). Twenty-one consecutive patients with focal ISR who underwent ELCA or CBA were enrolled. All patients underwent 12- to 15-month follow-up coronary angiography. OCT was performed immediately after successful PCI to evaluate the neointimal condition in the ISR lesion. We compared the following OCT parameters between ELCA and CBA groups: maximal thickness of remaining in-stent neointima (MTN), number of tears, minimum lumen dimension (MLD), and minimum lumen area (MLA). We also evaluated clinical outcomes, including target vessel revascularization, acute myocardial infarction, death, and stent thrombosis. MLA in the ELCA group (n = 10) was significantly larger than in the CBA group, and number of tears in the ELCA group was significantly lower than in the CBA group. A trend was shown toward lower TLR with ELCA versus CBA (10.0% vs 45.5%). OCT immediately after ELCA for ISR lesions revealed larger lumen area and smaller number of tears compared with CBA, which may support favorable effects of ELCA for focal ISR.

  18. Low-profile stent system for treatment of atherosclerotic renal artery stenosis : The GREAT trial

    NARCIS (Netherlands)

    Sapoval, Marc; Zahringer, Markus; Pattynama, Peter; Rabbia, Claudio; Vignali, Claudio; Maleux, Geert; Boyer, Louis; Szczerbo-Trojanowska, Malgorzata; Jaschke, Werner; Hafsahl, Geir; Downes, Mark; Beregi, Jean Paul; Veeger, Nic; Talen, Aly

    PURPOSE: The Palmaz Genesis Peripheral Stainless Steel Balloon Expandable Stent in Renal Artery Treatment (GREAT) Trial was designed to assess the safety and performance of a low-profile stent for the treatment of obstructive renal artery disease by looking at 6-month renal artery patency uniformly

  19. Interventional treatment of transplanted renal artery stenosis

    International Nuclear Information System (INIS)

    Zhang Zefu; Liang Huiming; Feng Gansheng; Zheng Chuansheng; Wu Hanpin; Zhou Guofeng

    2008-01-01

    Objective: To evaluate the treatment of transplanted renal artery stenosis (TRAS) by pereutaneous transluminal angioplasty (PTA)and stentplacement. Methods: The averange time from trans- plantation to the symptom occurrence of TRAS was 5.5 months (4-15 months)in 12 TRAS patients. All of them received the interventional therapy through femoral approach. Average BP, creatinine level and stenosis before and after the procedure were taken as the judgement standards. Results: PTA was performed with balloon (length 20-40 mm, diameter 5-7 mm)in 4 patients, stenting after PTA in 5, including 3 of direct stenting. Two cases (17%)occurred restenosis after PTA and restenting was undertaken. Three ases (25%)with restenosis after stentplacement were undergone PTA. One self-expandable stent and 9 balloon- dilatation stent were released in 10 eases. Stenosis significantly decreased from 65%-95% preoperatively to 15%-25% postoperatively, together with average BP decreased from 175/105 mmHg to 140/80 mmHg and creatinine level decreased from 475.5 μmol/L to 118.5 μmol/L. Among 12 cases included 4 healed, melioration (5), improvement (2), and inefficiency (1) during follow-up of 9 months (3-24 months). No complication occurred. Conclusion: The interventional therapy is effective and safe for TRAS with high rates of procedure success and efficacy. The proper selection of the adapted approach combined with PTA and stenting may effectively raise the long term efficacy for TRAS and success rate of the procedure. (authors)

  20. Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating

    Directory of Open Access Journals (Sweden)

    Saito N

    2016-03-01

    Full Text Available Noboru Saito, Yuhei Mori, Sayaka Uchiyama Terumo Corporation R&D Center, Inokuchi, Nakai-machi, Ashigarakami-gun, Kanagawa, Japan Abstract: The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC, which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion direction of the drug and the biological responses of the artery to drug-eluting stent (DES by comparing the AGC-sirolimus stent and the conventional full-surface coating (CFC sirolimus stent. The study aimed to verify whether the AGC approach was appropriate for the development of a safer DES, minimizing the risks of stent thrombosis due to delayed endothelialization by the drug and distal embolization due to cracking of the coating layer on the hinge parts of the DES on stent expansion. In the in vitro local drug diffusion study, we used rhodamine B as a model drug, and rhodamine B released from the AGC stent diffused predominantly into the abluminal side of the alginate artery model. Conversely, rhodamine B released from the CFC stent quickly spread to the luminal side of the artery model, where endothelial cell regeneration is required. In the biological responses study, the luminal surface of the iliac artery implanted with the AGC-sirolimus stent in a rabbit iliac artery for 2 weeks was completely covered with endothelial-like cells. On the other hand, the luminal surface of the iliac artery implanted with the CFC-sirolimus stent for 2 weeks only showed partial coverage with endothelial-like cells. While thrombosis was observed in two of the three CFC-sirolimus stents, it was observed in only one of the three AGC-sirolimus stents. Taken together, these findings indicate that the designed nonuniform coating (AGC is an appropriate approach to ensure a safer DES. However, the number of studies is limited and a larger study should be conducted to reach a statistically

  1. Investigation of adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents in the iliac vein: insights into developing a better iliac vein stent.

    Science.gov (United States)

    Shida, Takuya; Umezu, Mitsuo; Iwasaki, Kiyotaka

    2018-06-01

    We analyzed the adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents for the treatment of iliac venous thromboembolism and investigated their relationships with the anatomical features of the iliac vein, to gain insights into the development of a better iliac vein stent. Reports of adverse events following the use of stents in the iliac vein were retrieved from the Manufacturer and User Facility Device Experience (MAUDE) database that contain suspected device-associated complications reported to the Food and Drug Administration. Data from 2006 to 2016 were investigated. The literature analysis was also conducted using PubMed, Cochrane Library, EMBASE, and Web of Science focusing on English articles published up to 4 October 2016. The analysis of 88 adverse events from the MAUDE database and 182 articles from the literature revealed that a higher number of adverse events had been reported following the use of arterial stents in the iliac vein compared to CE-marked iliac vein stents. While stent migration and shortening were reported only for the arterial stents, stent fracture and compression occurred regardless of the stent type, even though a vein does not pulsate. A study of the anatomical features of the iliac vein implies that bending, compression, and kink loads are applied to the iliac vein stents in vivo. For designing, developing, and pre-clinical testing of stents intended for use in the iliac vein, the above mechanical load environments induced by the anatomical features should be considered.

  2. Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

    International Nuclear Information System (INIS)

    Rabellino, Martin; García-Nielsen, Luis; Zander, Tobias; Baldi, Sebastián; Llorens, Rafael; Maynar, Manuel

    2011-01-01

    Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.

  3. Progression of left main coronary artery disease 3 years after Bentall operation in a young female with Marfan syndrome.

    Science.gov (United States)

    Nishino, Tomohiro; Ehara, Natsuhiko; Kim, Kitae; Yamamuro, Atsushi; Kitai, Takeshi; Kobori, Atsushi; Kinoshita, Makoto; Kaji, Shuichiro; Tani, Tomoko; Okada, Yukikatsu; Furukawa, Yutaka

    2013-04-01

    A 39-year-old woman with Marfan syndrome presented to our hospital with chest oppression on effort. She underwent aortic root remodeling combined with aortic valve replacement 14 years ago and Bentall operation for enlargement of remaining native Valsalva sinus 3 years ago. A coronary computed tomography and a coronary angiography showed left main coronary artery stenosis, which was subsequently treated with percutaneous coronary intervention using a bare-metal stent. Follow-up coronary angiography performed 1 year after stenting revealed no restenosis.

  4. Percutaneous common femoral artery interventions using angioplasty, atherectomy, and stenting.

    Science.gov (United States)

    Mehta, Manish; Zhou, Yi; Paty, Philip S K; Teymouri, Medhi; Jafree, Kamran; Bakhtawar, Humayun; Hnath, Jeffrey; Feustel, Paul

    2016-08-01

    This study evaluated the feasibility, safety, and effectiveness of endovascular interventions for common femoral artery (CFA) occlusive disease. Using a prospectively maintained multicenter database, we analyzed outcomes in 167 consecutive patients who underwent percutaneous CFA interventions for Rutherford class 3 to class 6 (R3-R6) disease. The standardized treatment approach included primary percutaneous transluminal angioplasty (PTA) only, atherectomy + PTA, and provisional stenting. Outcomes included technical failure rate, recurrence, complications, and major or minor amputation rate. Data were analyzed using multivariate regression analysis. During a 7-year period, 167 patients with R3 (n = 91 [54.5%]) and R4 to R6 (n = 76 [45.5%]) disease underwent CFA interventions that included PTA only (n = 114 [68.2%]), atherectomy ± PTA (n = 38 [22.8%]), and provisional stenting (n = 15 [9.0%]) for failed atherectomy ± PTA. Procedure-related complications included pseudoaneurysm (n = 1 [0.6%]), thrombosis (n = 1 [0.6%]), distal embolization (n = 1 [0.6%]), and death (R6, n = 1 [0.06%]). CFA restenosis was observed in 34 (20.4%) patents; these underwent further percutaneous (n = 18 [10.8%]) or surgical (n = 17 [10.2%]) revascularization that included CFA endarterectomy ± femoral distal bypass. Major or minor amputations were observed in none of the R3 patients and in only three (3.9%) and five (6.5%) of the R4 to R6 patients, respectively. Compared with the atherectomy + PTA group, patients in the PTA-only group had a significantly lower patency. Furthermore, during long-term mean follow-up of 42.5 months, the CFA provisional stent group had a 100% primary patency, which was significantly better than the primary patency in the CFA nonstent groups combined (77.0%; P = .0424). Data from this study to date would suggest that percutaneous CFA interventions in select patients are relatively safe and effective. In the long term, CFA stenting has

  5. Drug-coated balloon angioplasty after directional atherectomy improves outcome in restenotic femoropopliteal arteries.

    Science.gov (United States)

    Sixt, Sebastian; Carpio Cancino, Oscar Gerardo; Treszl, András; Beschorner, Ulrich; Macharzina, Roland; Rastan, Aljoscha; Krankenberg, Hans; Neumann, Franz-Josef; Zeller, Thomas

    2013-09-01

    Restenosis remains an unresolved problem despite different treatment modalities and new stent technology in femoropopliteal arteries. No standard therapy has proven to provide acceptable outcome data for this entity. Directional atherectomy alone did not result in satisfactory long-term patency rates. The outcome might be improved in conjunction with drug-coated balloon angioplasty. In this retrospective study, restenotic lesions of the femoropopliteal arteries were treated with directed atherectomy in 89 lesions of consecutive patients (58% male; mean age, 69 ± 11 years). All patients received adjunctive treatment with conventional balloon percutaneous angioplasty (PTA; n = 60) or drug-coated balloon angioplasty (DCB; n = 29). Lesion location was in the stent (DCB [n = 27] vs PTA [n = 36]) and in native restenotic vessels (DCB [n = 2] vs PTA [n = 25]). The 1-year Kaplan-Meier freedom from restenosis estimates (95% confidence intervals) in the DCB and PTA groups were 84.7% (70.9%-98.5%) and 43.8% (30.5%-57.1%), respectively. In a multivariable Cox model for restenosis, DCB treatment had a hazard ratio (95% confidence interval) of 0.28 (0.12-0.66; P = .0036) compared with the PTA group. In the multivariable model for procedural success, the effect of treatment did not differ between PTA and DCB (P = .134). The combination of directed atherectomy with adjunctive DCB is associated with a better event-free survival at 12 months of follow-up compared with PTA after directed atherectomy. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  6. Enterprise stent in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion.

    Science.gov (United States)

    Wang, Xiaofei; Wang, Zhigang; Ji, Yong; Ding, Xuan; Zang, Yizheng; Wang, Chengwei

    2017-11-01

    To investigate the safety and effectiveness of recanalization in non-acute occlusion of intracranial internal carotid arteries using the flexible Enterprise self-expanding stent. From June 2014 to June 2016, 12 consecutive patients with non-acute occlusion of intracranial internal carotid arteries received endovascular recanalization with Enterprise stenting. All patients received medication for anti-platelet aggregation therapy before and after the operation. The perioperative complications and recanalization efficacy were evaluated with the modified Rankin scoring system and digital subtraction angiography (DSA) follow-up, respectively. Endovascular recanalization was successfully performed in 10 out of 12 patients with Enterprise stenting. Stent implantation following balloon dilatation failed in one patient because the lumen diameter was too small. Another recanalization failed because the guide wire could not pass through the occlusion. No perioperative mortality was observed. One case of acute thrombosis and one case of intraoperative carotid spasm occurred, but these were resolved with thrombolytic therapy by microcatheter exposure treatment and antispasmodic medications, respectively. DSA follow-up in seven patients revealed no re-occlusion. One stroke event occurred in the 10 patients who completed the follow-up. A meaningful improvement in the modified Rankin score during follow-up was suggested by Wilcoxon signed-rank test results. The Enterprise stent was shown to be safe and efficient in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion. However, the long-term outcomes need to be further investigated. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.

    Science.gov (United States)

    Mahfoud, Felix; Tunev, Stefan; Ruwart, Jennifer; Schulz-Jander, Daniel; Cremers, Bodo; Linz, Dominik; Zeller, Thomas; Bhatt, Deepak L; Rocha-Singh, Krishna; Böhm, Michael; Melder, Robert J

    2014-12-01

    In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA. We report marked blood pressure reduction after RDN in a patient with resistant hypertension who underwent previous stenting. Subsequently, radiofrequency ablation was investigated within the stented segment of porcine RA, distal to the stented segment, and in nonstented RA and compared with stent only and untreated controls. There were neither observations of thrombus nor gross or histological changes in the kidneys. After radiofrequency ablation of the nonstented RA, sympathetic nerves innervating the kidney were significantly reduced, as indicated by significant decreases in sympathetic terminal axons and reduction of norepinephrine in renal tissue. Similar denervation efficacy was found when RDN was performed distal to a renal stent. In contrast, when radiofrequency ablation was performed within the stented segment of the RA, significant sympathetic nerve ablation was not seen. Histological observation showed favorable healing in all arteries. Radiofrequency ablation of previously stented RA demonstrated that RDN provides equally safe experimental procedural outcomes in a porcine model whether the radiofrequency treatment is delivered within, adjacent, or without the stent struts being present in the RA. However, efficacious RDN is only achieved when radiofrequency ablation is delivered to the nonstented RA segment distal to the stent. © 2014 American Heart Association, Inc.

  8. Nanotechnology in diagnosis and treatment of coronary artery disease.

    Science.gov (United States)

    Karimi, Mahdi; Zare, Hossein; Bakhshian Nik, Amirala; Yazdani, Narges; Hamrang, Mohammad; Mohamed, Elmira; Sahandi Zangabad, Parham; Moosavi Basri, Seyed Masoud; Bakhtiari, Leila; Hamblin, Michael R

    2016-01-01

    Nanotechnology could provide a new complementary approach to treat coronary artery disease (CAD) which is now one of the biggest killers in the Western world. The course of events, which leads to atherosclerosis and CAD, involves many biological factors and cellular disease processes which may be mitigated by therapeutic methods enhanced by nanotechnology. Nanoparticles can provide a variety of delivery systems for cargoes such as drugs and genes that can address many problems within the arteries. In order to improve the performance of current stents, nanotechnology provides different nanomaterial coatings, in addition to controlled-release nanocarriers, to prevent in-stent restenosis. Nanotechnology can increase the efficiency of drugs, improve local and systematic delivery to atherosclerotic plaques and reduce the inflammatory or angiogenic response after intravascular intervention. Nanocarriers have potential for delivery of imaging and diagnostic agents to precisely targeted destinations. This review paper will cover the current applications and future outlook of nanotechnology, as well as the main diagnostic methods, in the treatment of CAD.

  9. Comparative vascular responses three months after paclitaxel and everolimus-eluting stent implantation in streptozotocin-induced diabetic porcine coronary arteries

    Directory of Open Access Journals (Sweden)

    Sheehy Alexander

    2012-06-01

    Full Text Available Abstract Background Diabetes remains a significant risk factor for restenosis/thrombosis following stenting. Although vascular healing responses following drug-eluting stent (DES treatment have been characterized previously in healthy animals, comparative assessments of different DES in a large animal model with isolated features of diabetes remains limited. We aimed to comparatively assess the vascular response to paclitaxel-eluting (PES and everolimus-eluting (EES stents in a porcine coronary model of streptozotocin (STZ-induced type I diabetes. Method Twelve Yucatan swine were induced hyperglycemic with a single STZ dose intravenously to ablate pancreatic β-cells. After two months, each animal received one XIENCE V® (EES and one Taxus Liberte (PES stent, respectively, in each coronary artery. After three months, vascular healing was assessed by angiography and histomorphometry. Comparative in vitro effects of everolimus and paclitaxel (10-5 M–10-12 M after 24 hours on carotid endothelial (EC and smooth muscle (SMC cell viability under hyperglycemic (42 mM conditions were assayed by ELISA. Caspase-3 fluorescent assay was used to quantify caspase-3 activity of EC treated with everolimus or paclitaxel (10-5 M, 10-7 M for 24 hours. Results After 3 months, EES reduced neointimal area (1.60 ± 0.41 mm, p vs. 0.08 ± 0.05, greater medial necrosis grade (0.52 ± 0.26 vs. 0.0 ± 0.0, and persistently elevated fibrin scores (1.60 ± 0.60 vs. 0.63 ± 0.41 with PES compared to EES (p In vitro, paclitaxel significantly increased (p -7 M, while everolimus did not affect EC/SMC apoptosis/necrosis within the dose range tested. In ECs, paclitaxel (10-5 M significantly increased caspase-3 activity (p  Conclusion After 3 months, both DES exhibited signs of delayed healing in a STZ-induced diabetic swine model. PES exhibited greater neointimal area, increased inflammation, greater medial necrosis, and

  10. Efficacy of different types of self-expandable stents in carotid artery stenting for carotid bifurcation stenosis.

    Science.gov (United States)

    Liu, Ya-min; Qin, Hao; Zhang, Bo; Wang, Yu-jing; Feng, Jun; Wu, Xiang

    2016-02-01

    Both open and closed loop self-expandable stents were used in carotid artery stenting (CAS) for carotid bifurcation stenosis. We sought to compare the efficacy of two types of stents in CAS. The data of 212 patients treated with CAS (42 and 170 cases implanted with closed and open loop stents, respectively) for carotid bifurcation stenosis and distal filtration protection devices were retrospectively analyzed. Between closed and open loop stents, there were no significant differences in hospitalization duration, NIHSS score before and after the treatment, stenosis at 12th month, and cumulative incidence of primary endpoint events within 30 days or from the 31st day to the 12th month; while there were significant differences in hemodynamic changes and rate of difficulty in recycling distal filtration protection devices. Use of open vs. closed loop stents for carotid bifurcation stenosis seems to be associated with similar incidence of complications, except for greater rate of hemodynamic changes and lower rate of difficulty in recycling the distal filtration protection devices.

  11. Comparison of Immediate and 2-Year Outcomes between Excimer Laser-Assisted Angioplasty with Spot Stent and Primary Stenting in Intermediate to Long Femoropopliteal Disease

    Directory of Open Access Journals (Sweden)

    Tien-Yu Wu

    2013-01-01

    Full Text Available Background. To compare the clinical outcomes between excimer laser-assisted angioplasty (ELA with spot stent (group A and primary stenting (group B in intermediate to long femoropopliteal disease. Methods. Outcomes of 105 patients totaling 119 legs treated with two different strategies were analyzed retrospectively in a prospectively maintained database. Results. Baseline characteristics were similar in both groups. Better angiographic results and lesser increase of serum C-reactive protein levels (0.60 ± 0.72 versus 2.98 ± 0.97 mg/dL, P<0.001 after the intervention were obtained in Group B. Group A had inferior 1-year outcomes due to higher rate of binary restenosis (67% versus 32%, P=0.001 and lower rate of primary patency (40% versus 58%, P=0.039. Rates of amputation-free survival, target vessel revascularization, assisted primary patency, and stent fracture at 24 months were similar in both groups (80% versus 82%, P=0.979, 65% versus 45%, P=0.11, 78% versus 80%, P=0.75 and 6.3% versus 6.8%, P=0.71, resp.. Conclusion. Greater vascular inflammation after ELA with spot stent resulted in earlier restenosis and inferior 1-year clinical outcomes than primary stenting. This benefit was lost in the primary stenting group at 2 years due to late catch-up restenosis. Active surveillance with prompt intervention was required to maintain the vessel patency.

  12. Advances in Study of Absorbable Metal Stent in Coronary Artery%冠状动脉内可吸收金属支架的研究进展

    Institute of Scientific and Technical Information of China (English)

    刘艳青

    2012-01-01

    冠状动脉内支架植入是目前广泛应用的冠心病治疗手段,但支架内狭窄和晚期血栓形成影响冠状动脉支架远期疗效和安全性,长期应用抗血小板药物所带来的不良反应以及经济上给患者造成的负担,这些都限制了冠状动脉支架的进一步应用.生物可吸收金属支架具有与裸金属支架相当的支撑力及良好生物相容性,可有效降低再狭窄率和血栓形成,临床应用前景十分广阔.%Currently, coronary stents are widely used in the treatment of coronary heart disease. However, the major limitations of stents are in-stent restenosis and late thrombosis. These , which effect the long-term efficiency and safety of the stents. Moreover, prolonged antiplatelet therapy can have many adverse effects and economic burdens for a patient , and these factors limit the further development of stents. The use of a bioabsorbable metal stent which could provide the same mechanical properties compared to the bare metal stent and but with good bio-compatibility, could reduce the rate of restenosis and thrombosis. It owns a bright future in clinical coronary stents.

  13. A method to determine the kink resistance of stents and stent delivery systems according to international standards

    Directory of Open Access Journals (Sweden)

    Brandt-Wunderlich Christoph

    2016-09-01

    Full Text Available The kink behavior of vascular stents is of particular interest for clinicians, stent manufacturers and regulatory as a kinked stent generates a lumen loss in the stented vessel and can lead to in-stent restenosis. In this study methods to determine the kink resistance of stents and stent delivery systems according to the ISO 25539-2 and FDA guidance no. 1545 were presented. The methods are applicable for balloon expandable stents as well as for self-expanding stents and determine the lumen loss and residual diameter change dependent on the specific bending radius.

  14. Protein losing enteropathy secondary to a pulmonary artery stent

    Directory of Open Access Journals (Sweden)

    Narayanswami Sreeram

    2012-01-01

    Full Text Available A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE. He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion. Combined bronchoscopic and catheterization studies during spontaneous breathing confirmed left bronchial stenosis behind the stent, and diastolic systemic ventricular pressure during expiration of 25 mm Hg. We postulate that the stent acts as a valve, against which the patient generates high expiratory pressures, which are reflected in the ventricular diastolic pressure. This may be the cause of PLE.

  15. Safety of non-ionic contrast media during renal artery stenting

    International Nuclear Information System (INIS)

    Ni Jun; Shen Weifeng; Zhang Ruiyan; Zhang Qi; Zhang Xian; Zheng Aifang

    2004-01-01

    Objective: To evaluate the safety of non-ionic contras media during interventional treatment of renal artery stenosis (RAS). Methods: Fifty four coronary artery disease patients associated with RAS (luminal narrowing > 50%) underwent renal artery stent implantation and percutaneous coronary intervention, only 10 of them with merely renoarterial stenosis undergone renal artery stent implantation. The successful rates of the procedure and complication together with the volumes of contrast media were recorded respectively. And the serum creatine before and 12 hours after the successful procedure were also measured. Results: Both rates of procedural success and complication were similar among the three groups. The serum creatine levels, 12 hours after the procedure, showed no difference in comparing with the baseline. Conclusion: Non-ionic contrast media (Iopamiro 370) could be safely used in patients with RAS. (authors)

  16. Restenosis: A Challenge to Angioplasty

    Indian Academy of Sciences (India)

    Smooth muscle cells from the internal elastic membrane and ... atherosclerosis. In addition to LDL other risk factors for athero- ... The present management of restenosis is ... lumen, while the control artery had developed stenosis (Figure 5).

  17. Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers

    Directory of Open Access Journals (Sweden)

    Brendan Doyle

    2009-11-01

    Full Text Available Brendan Doyle, David R Holmes JrDivision of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic College of Medicine, Rochester, Minnesota, USAAbstract: The success of drug-eluting stents in preventing restenosis has shifted the focus of new stent development toward enhancing long term safety and efficacy of these devices, while simultaneously eliminating the need for indefinite dual antiplatelet therapy. A technical advance fulfilling these aims would hold tremendous potential to reduce morbidity, mortality and economic costs associated with the percutaneous treatment of coronary artery disease. An attractive approach is the use of bioabsorbable stent designs. These may include stents with different bioabsorbable drugs, bioabsorbable polymers or even bioabsorbable metallic backbones. A device that could achieve excellent acute and long-term results, but disappear completely within months (thereby avoiding the need for prolonged dual antiplatelet therapy, would be a tremendous advance. Too good to be true? We explore here the scientific rationale and prospects for success with this exciting concept.Keywords: percutaneous coronary intervention, biodegradable, bioabsorbable, polymer, stent

  18. DK mini-culotte stenting in the treatment of true coronary bifurcation lesions: a propensity score matching comparison with T-provisional stenting.

    Science.gov (United States)

    Fan, Lin; Chen, Lianglong; Luo, Yukun; Zhang, Linlin; Zhong, Wenliang; Lin, Chaogui; Chen, Zhaoyang; Peng, Yafei; Zhen, Xingchun; Dong, Xianfeng

    2016-03-01

    The conventional culotte technique remains not to be widely used for the treatment of coronary bifurcation lesions due to its inherent drawbacks. Here, we developed a double kissing mini-culotte stenting (DK mini-culotte) and assessed its efficacy and safety by a propensity score matching comparison (PSM) with T-provisional stenting. From June 2010 to June 2012, a total of 223 consecutive patients with true coronary bifurcation lesions (TCBLs) were treated with DK mini-culotte (91 patients with 92 lesions) or T-provisional stenting (132 patients with 135 lesions). We performed a PSM to correct the confounders from clinical and lesion's characteristics. The primary endpoint was cumulative major adverse cardiac event (MACE) at 1 year including cardiac death, myocardial infarction, and target vessel revascularization or target lesion revascularization (TVR/TLR). The secondary endpoint was the rate of side branch (SB) restenosis at 12 months. After a PSM, there were 66 patients in each group. Additional SB stenting in the T-provisional group was performed in 10 (15.2 %) lesions. The incidence of 1-year cumulative MACE was 4.55 % for the DK mini-culotte versus 13.6 % for T-provisional stenting (P = 0.127), the rate of TVR/TLR was 1.52 % for DK mini-culotte versus 12.12 % for T-provisional stenting (P = 0.033). The SB binary restenosis rate was 5.6 % in the DK mini-culotte group and 22.4 % in the T-provisional group (P = 0.014). In summary, despite that there is no difference in MACE between groups, DK mini-culotte significantly reduce TVR/TLR and SB restenosis in the treatment of true coronary bifurcation lesions.

  19. ILIAC-ARTERY URETERAL-FISTULA ASSOCIATED WITH AN INDWELLING URETERAL STENT

    NARCIS (Netherlands)

    ZWEERS, HMM; VANDRIEL, MF; MENSINK, HJA

    1991-01-01

    We report on a patient with an ureteroiliac artery fistula, which developed after double J stenting. The stent was introduced because of unilateral hydronephrosis 2 months after a Wertheim-Meigs operation preceded by cesium application. The presenting symptom of gross hematuria was initially

  20. Prognostic value of renal fractional flow reserve in blood pressure response after renal artery stenting (PREFER study).

    Science.gov (United States)

    Kądziela, Jacek; Januszewicz, Andrzej; Prejbisz, Aleksander; Michałowska, Ilona; Januszewicz, Magdalena; Florczak, Elżbieta; Kalińczuk, Łukasz; Norwa-Otto, Bożena; Warchoł, Ewa; Witkowski, Adam

    2013-01-01

    The aim of our study was to determine a potential relationship between resting translesional pressures ratio (Pd/Pa ratio), renal fractional flow reserve (rFFR) and blood pressure response after renal artery stenting. Thirty five hypertensive patients (49% males, mean age 64 years) with at least 60% stenosis in angiography, underwent renal artery stenting. Translesional systolic pressure gradient (TSPG), Pd/Pa ratio (the ratio of mean distal to lesion and mean proximal pressures) and hyperemic rFFR - after intrarenal administration of papaverine - were measured before stent implantation. Ambulatory blood pressure measurements (ABPM) were recorded before the procedure and after 6 months. The ABPM results were presented as blood pressure changes in subgroups of patients with normal (≥ 0.9) vs. abnormal (renal artery stenting. Median changes of 24-h systolic/diastolic blood pressure were comparable in patients with abnormal vs. normal Pd/Pa ratio (-4/-3 vs. 0/2 mm Hg; p = NS) and with abnormal vs. normal rFFR (-2/-1 vs. -2/-0.5 mm Hg, respectively). Physiological assessment of renal artery stenosis using Pd/Pa ratio and papaverine- induced renal fractional fl ow reserve did not predict hypertension response after renal artery stenting.

  1. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    Science.gov (United States)

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  2. Primary Stenting of Subclavian and Innominate Artery Occlusive Disease: A Single Center's Experience

    International Nuclear Information System (INIS)

    Brountzos, E. N.; Petersen, B.; Binkert, C.; Panagiotou, I.; Kaufman, J. A.

    2004-01-01

    Purpose: To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Methods: Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Results: Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Conclusion: Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions

  3. Beyond Oncogenesis: The Role of S-Phase Kinase-Associated Protein-2 (SKP2 In Vascular Restenosis

    Directory of Open Access Journals (Sweden)

    Yih-Jer Wu

    2008-12-01

    Full Text Available The clinical benefits of percutaneous coronary intervention, the most prevalent procedure nowadays for the treatment of symptomatic coronary artery disease, are frequently offset by the occurrence of vascular restenosis. Although the introduction of drug-eluting stents has significantly reduced restenotic rates, the rare, but potentially fatal, delayed thrombosis remains a clinical threat. Further refinement of the drug-eluting stent based on a better understanding of cell cycle regulation between the vascular smooth muscle cell (VSMC and endothelial cell (EC is required. In this review, we discuss the role of S-phase kinase-associated protein-2 (Skp2, previously known as an oncoprotein, in the regulation of VSMC proliferation and its signaling axis. The currently available evidence suggests that the Rac1-Skp2-p27Kip1 signaling axis acts as a common final pathway for many factors that regulate VSMC proliferation, such as growth factors, extracellular matrices and cyclic nucleotides. Importantly, although EC proliferation is also shown to be regulated by the same axis, cAMP seems to regulate this axis differentially between VSMC and EC, rendering the underlying mechanism of this differential regulation a promising target for the development of a new generation of drug-eluting stent.

  4. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions: 3-year results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) trial

    DEFF Research Database (Denmark)

    Kelbaek, H.; Klovgaard, L.; Helqvist, S.

    2008-01-01

    data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... performed between 1 and 3 years after the index treatment (p = NS). According to revised definitions, stent thrombosis occurred in 5 patients (3.1%) in the SES group and in 7 patients (4.4%) in the BMS group (p = NS); very late stent thrombosis was observed in 4 versus 1 patient. CONCLUSIONS: A continued...

  5. Off-pump coronary artery bypass grafting or percutaneous transluminal coronary angioplasty with stenting for proximal left anterior descending coronary artery disease?

    NARCIS (Netherlands)

    Drenth, Derk Jan

    2005-01-01

    This thesis describes and discusses the results of a prospective randomized controlled clinical trial comparing percutaneous coronary angioplasty with stenting (stenting) and off-pump coronary artery bypass grafting with a left internal mammary artery (surgery) in patients with a high-grade stenosis

  6. Dual-therapy stent technology for patients with coronary artery disease : A great catch?

    NARCIS (Netherlands)

    Kalkman, D.N.

    2018-01-01

    This thesis investigates the possible advantages of a new stent technology that aims to improve care for patients with coronary artery disease. The COMBO stent (OrbusNeich Medical BV, The Netherlands) contains a dual-therapy stent technology. The stent combines two techniques: a sirolimus-elution

  7. Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

    Energy Technology Data Exchange (ETDEWEB)

    Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2012-12-15

    We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

  8. Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

    International Nuclear Information System (INIS)

    Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko

    2012-01-01

    We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

  9. Angle change of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms

    International Nuclear Information System (INIS)

    Cho, W.-S.; Kang, H.-S.; Kim, J.E.; Kwon, O.-K.; Oh, C.W.; Cho, Y.D.; Han, M.H.

    2014-01-01

    Aim: To investigate the angle changes of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms. Materials and methods: The adjacent parent arterial angles before and after stent-assisted coil embolization were measured in 38 patients with aneurysms of the anterior communicating artery (ACoAA) and 41 patients with bifurcation aneurysms of the middle cerebral artery (MCABA). Variables were analysed in relation to the angle changes. Results: Vascular angles of the parent arteries significantly increased by 27.8° (±18.5°) immediately after stent-assisted coil embolization in 79 cases (p < 0.001), with 25.7° (±14.8°) in ACoAA and 29.7° (±21.4°) in MCABA, respectively. In 51 (64.6%) cases with follow-up angiography (mean interval 13.5 ± 4.1 months), vascular angles increased by 27.2° (±17.1°) immediately after treatment and further increased by 20.7° (±14.3°) at the last follow-up (all p < 0.001). More acute pre-stent angles of the parent arteries correlated with greater post-stent angle changes (p = 0.006). Younger age tended to be inversely related to post-stent angle changes (p = 0.091). Conclusion: Stent placement during coil embolization induced significant changes in the aneurysm–parent artery relationship. Further study is needed to elicit the association between angle change of the parent arteries and aneurysmal stability after coil embolization

  10. Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).

    Science.gov (United States)

    Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK

    1996-10-01

    Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.

  11. Impact of the use of antibodies anti endothelin 1 on the coronary arterial estenosis for hyperplasia secondary neo intimal to barotraumas with ball and Stent in porcines

    International Nuclear Information System (INIS)

    Pineda V, Mauricio; Maldonado, Luz A; Uribe, Ana Maria and others

    2003-01-01

    Coronary angioplasty (PTCA) is performed in about two million surgical procedures every year in the world, and coronary restenosis (CR) continues to be it's weakest point. There are four mechanisms involved in CR 1. Thrombosis, 2.elastic recoil, 3. Constrictive arterial remodeling; and 4. Intimal hyperplasia. The first three are managed with Stents, inhibitors of GP lib//iiia, antiagregants and anticoagulants. The fourth is believed to be the only responsible of post Stent CR. endothelin 1(ET1) produces cellular proliferation. Impact of the anti ET1 anti bodies by intra coronary injection, or generated by immune response at the subcutaneous (SC) application of ET1, on the NI growth in porcines, who have undergone barotrauma with Stent, is expected to be demonstrated. PTCA was performed in 12 pigs (36 arterial specimens). They were sacrificed after four weeks of follow up. Specimens were divided in three groups, previously randomized, resulting in 12 specimens a group. The placebo group received intracoronary infusion of saline solution immediately after the barotraumas. The second group received intracoronary infusion of AET1 antibodies and the third group received SC injection of ET1 fourteen days before the trauma. Segments were studied with IVUS and hystomotphometric analysis. Statistical analysis: it was performed by the student t in order to compare independent measures. Because of the small size of the groups, the Mann Whitney test was applied. A double tale analysis was performed in both cases. A significant reduction of the NI area was obtained both with the injection of AET1 Abs and ET1 SC (p 0.001) in the IVUS and the hystomotphometric analyses. AET1 antibodies seem to prevent the post Stent NI growth. There is no significant advantage between both forms of injection

  12. Short-term safety and efficacy of the biodegradable iron stent in mini-swine coronary arteries

    Institute of Scientific and Technical Information of China (English)

    WU Chao; QIU Hong; HU Xiao-ying; RUAN Ying-mao; TIAN Yi; CHU Yan; XU Xin-lin

    2013-01-01

    Background To overcome the drawbacks of permanent stents,biodegradable stents have been studied in recent years.The bioabsorbable polymer vascular scaffold (BVS) was the first bioabsorbable stent to undergo clinical trials,demonstrating safety and feasibility in the ABSORB studies.Iron can potentially serve as the biomaterial for biodegradable stents.This study aimed to assess the short-term safety and efficacy of a biodegradable iron stent in mini-swine coronary arteries.Methods Eight iron stents and eight cobalt chromium alloy (VISION) control stents were randomly implanted into the LAD and RCA of eight healthy mini-swine,respectively.Two stents of the same metal base were implanted into one animal.At 28 days the animals were sacrificed after coronary angiography,and histopathological examinations were performed.Results Histomorphometric measurements showed that mean neointimal thickness ((0.46±0.17) mm vs.(0.45±0.18)mm,P=0.878),neointimal area ((2.55±0.91) mm2 vs.(3.04±1.15) mm2,P=0.360) and percentage of area stenosis ((44.50±11.40)% vs.(46.00±17.95)%,P=0.845) were not significantly different between the iron stents and VISION stents.There was no inflammation,thrombosis or necrosis in either group.The scanning electron microscopy (SEM) intimal injury scores (0.75±1.04 vs.0.88±0.99,P=0.809) and number of proliferating cell nuclear antigen (PCNA) positive staining cells were not significantly different between the two groups.The percentage of neointimal coverage by SEM examination was numerically higher in iron stents than in VISION stents ((84.38±14.50)% vs.(65.00±22.04)%,P=0.057),but the difference was not statistically significant.Iron staining in the tissue surrounding the iron stents at 28 days was positive and the vascular wall adjacent to the iron stent had a brownish tinge,consistent with iron degradation.No abnormal histopathological changes were detected in coronary arteries or major organs.Conclusions The biodegradable iron stent has

  13. Metallic Zinc Exhibits Optimal Biocompatibility for Bioabsorbable Endovascular Stents

    Science.gov (United States)

    Bowen, Patrick K.; Guillory, Roger J.; Shearier, Emily R.; Seitz, Jan-Marten; Drelich, Jaroslaw; Bocks, Martin; Zhao, Feng; Goldman, Jeremy

    2015-01-01

    Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5 months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5 months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells. PMID:26249616

  14. Incremental benefit of three-dimensional transesophageal echocardiography in the assessment of left main coronary artery stent protrusion.

    Science.gov (United States)

    Arisha, Mohammed J; Hsiung, Ming C; Ahmad, Amier; Nanda, Navin C; Elkaryoni, Ahmed; Mohamed, Ahmed H; Yin, Wei-Hsian

    2017-06-01

    Ostial lesions represent a challenging clinical scenario and percutaneous intervention (PCI) of left main coronary artery ostial lesions has been associated with postintervention complications, including protrusion of deployed stents into a sinus of Valsalva or aortic root. We report a case of stent protrusion into the aortic root following aorto-ostial left main coronary artery PCI, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Specifically, 3DTEE confirmed the presence of stent protrusion by allowing clear visualization of the stent scaffold, in addition to characterizing the relationship between the stent and surrounding structures. © 2017, Wiley Periodicals, Inc.

  15. Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele

    2016-08-01

    To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.

  16. Thirty-day outcomes of direct carotid artery stenting with cerebral protection in high-risk patients

    International Nuclear Information System (INIS)

    Veselka, J.; Cerna, D.; Zimolova, P.; Blasko, P.; Fiedler, J.; Hajek, P.; Maly, M.; Zemanek, D.; Duchonova, R.

    2007-01-01

    Implantation of a carotid artery stent after predilation is a standard approach in the endovascular treatment of carotid artery stenoses. Stenting without predilation may be an alternative approach in a certain subset of patients. The present prospective, single-center registry was designed to evaluate the feasibility and safety of direct carotid artery stenting (DCAS) in high-risk patients. Symptomatic patients with stenosis >50% and asymptomatic patients with stenosis >70% were eligible for enrolment. Criteria for high-risk patients included: need or history of open heart surgery, history of myocardial infarction, multivessel coronary artery disease, left ventricular dysfunction (ejection fraction ≤40%), severe pulmonary or renal disease, significant contralateral carotid disease, previous endarterectomy, and age ≥80 years. All procedures were performed using a filter protection device. Patients underwent complete clinical examination before and after DCAS and at 30-day follow-up. A total of 83 consecutive patients (45 males, 68±9 years, 33% symptomatic) underwent 100 procedures and 103 stents were deployed successfully. The technical success rate of stenting was 100%. Predilation of carotid stenosis was necessary in 1 (1%) procedure. Carotid-artery stenoses before and after DCAS were 80±9% and 7±9%, respectively. The median fluoroscopic time for DCAS was 7 min. The overall rate of in-hospital major adverse cerebrovascular events (death, stroke, myocardial infarction) was 5% (2 minor strokes, 3 transient attacks). There was 1 (1%) minor stroke within the 30-day follow-up. DCAS is feasible and can be performed with an acceptable risk in high-risk patients. (author)

  17. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  18. Outcomes of emergent carotid artery stenting within 6 hours of symptom onset in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Jeong, Won Gi; Yoon, Woong; Yim, Nam Yeol; Jung, Min Young; Jung, Se Hee; Kang, Heoung Keun

    2013-01-01

    To investigate clinical outcomes following the emergent carotid artery stenting for treatment of acute ischemic stroke. Twenty-eight consecutive patients with acute stroke due to atherosclerotic steno-occlusive diseases of extracranial internal carotid artery underwent emergent carotid artery stenting. Of these, 23 patients had tandem intracranial arterial occlusions. Extracranial carotid stenting was successful in all patients. From the 13 patients who underwent intracranial recanalization procedures, successful recanalization occurred in 84.6% (11/13). 57% of patients (16/28) had a good clinical outcome (modified Rankin Scale 0-2) after 3 months. Patients with successful intracranial/extracranial recanalization had a significantly higher rate of good outcome than those without recanalization after 3 months (75% vs. 33%, p = 0.027). Patients without intracranial tandem occlusions had a more favorable clinical outcome than those with intracranial tandem occlusions (100% vs. 48%, p = 0.033). Symptomatic intracerebral hemorrhage occurred in one patient (3.6%). Mortality rate was 0% (0/28) after 3 months. Emergent carotid artery stenting in setting of acute stroke was a safe and effective treatment modality. Successful recanalization (extracranial and intracranial) and absence of intracranial tandem occlusion are significantly associated with a good outcome for our cohort of patients whom undergone emergent carotid artery stenting.

  19. Evaluation of batroxobin in preventing vascular restenosis in diabetic patients after infrapopliteal arterial angioplasty: a randomized comparative study

    International Nuclear Information System (INIS)

    Xue Bo; Zhang Peilei; Wang Jue; Li Minghua; Zhao Jungong; Zhu Yueqi; Tan Huaqiao; Wang Jianbo

    2011-01-01

    Objective: To evaluate batroxobin in preventing vascular restenosis in diabetic patients after infrapopliteal arterial angioplasty through comparing the clinical results of the combination use of batroxobin and aspirin with that of simple use of aspirin. Methods: After a successful angioplasty, fifty-two diabetic patients with symptomatic infrapopliteal obstructions were randomly divided into the study group (n=26) and the control group (n=26). Patients in both groups received 100 aspirin everyday, but the patients in study group additionally received 5 IU batroxobin intravenous drip every day for six times. At the end of the follow-up period lasting for 12 months, magnetic resonance angiography (MRA) or Doppler ultrasonic angiography was performed to check the vessels to see if there was any restenosis or reocclusion. The relief degree of clinical symptoms were observed, and both preoperative and postoperative ankle-brachial index (ABI) were regularly determined and compared. Kaplan-Meier curves were constructed to evaluate restenosis/reocclusion-free rate, limb salvage rate and amputation-free rate. Results: During the follow-up period the occurrence of restenosis/reocclusion in study group and control group was 22.0% and 34.5% respectively (P=0.0307). Statistically significant difference in ABI existed between two groups both after the procedure (P<0.05) and at 12 months after the treatment (P=0.0094). Clinical improvement and tissue healing in study group and control group were observed in 23 and 19 patients respectively (P=0.0544). Twelve months after angioplasty, Kaplan-Meier analysis showed that the restenosis/reocclusion-free rate, the limb salvage rate and the amputation-free rate for study group were 74.0%, 96.2% and 84.6% respectively, while they was 54.8%, 92.3% and 84.6% respectively for control group. Conclusion: The results of this study indicate that the use of the clinical therapeutic efficacy and markedly relieve the symptoms, although this

  20. Conformally integrated stent cell resonators for wireless monitoring of peripheral artery disease

    KAUST Repository

    Viswanath, Anupam; Green, Scott Ryan; Kosel, Jü rgen; Gianchandani, Yogesh B.

    2013-01-01

    This paper presents the design and in vitro evaluation of magnetoelastic sensors intended for wireless monitoring of tissue accumulation in peripheral artery stents. The sensors, shaped like stent cells, are fabricated from 28-μm thick foils

  1. Clinical experience of cerebral protection with balloon occlusion during carotid artery stenting

    International Nuclear Information System (INIS)

    Jaeger, H.J.; Mathias, K.D.; Drescher, R.; Bockisch, G.; Hauth, E.; Demirel, E.; Gissler, H.M.; Witten/Herdecke Univ.

    2001-01-01

    Purpose: To asses the technical feasibility and the results of cerebral protection with the GuardWire Plus Temporary Occlusion and Aspiration System during carotid artery stenting for high-grade stenosis. Patients and Methods: In 20 patients 20 carotid artery stenoses were treated with stent placement under cerebral protection. A contralateral carotid occlusion was an exclusion criteria for the use of the protection device. In all cases only aspiration, but no flushing was used before deflation of the occlusion balloon. In 17 of 20 patients diffusion-weighted (DW-)MRT imaging of the brain was performed before and 24 hours after the procedure. Results: The stent implantation was successfully performed in all patients. In 3 patients neurologic symptoms occurred during the occlusion time. In these 3 patients the symptoms immediately disappeared after deflation of the balloon. In one case there was dilatation of the internal carotid artery at the site of the balloon inflation. In 3 of the 17 DW-MR images new ipsilateral cerebral lesions, in one case a new contralateral lesion occurred after the procedure. Conclusions: The cerebral protection procedure is technically feasible. The occlusion of the internal carotid artery was not tolerated by all patients. The DW-MR imaging demonstrated cerebral lesions indicating the occurrence of cerebral microemboli during the procedure. Further investigations are necessary to determine if the use of the cerebral protection device will improve the results of the carotid artery stenting for high-grade stenoses. (orig.) [de

  2. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  3. Clinical evaluation of the efficacy and influencing factors for stent placement in treating benign and malignant esophageal stenosis

    International Nuclear Information System (INIS)

    Guo Xiaohua; He Jianrong; Lin Kaiqin; Jin Honglai; Li Maoquan; Zhang Qing

    2003-01-01

    Objective: To evaluate clinical effectiveness and influence factors in the treatment of benign and malignant esophageal stenosis by placing esophageal stent. Methods: A series of this research comprised of 29 cases with esophageal cancer, 10 cardiac carcinoma, 5 cardiac achalasia, 6 benign esophageal stricture after operation. The lengths of lesion ranged from 2 to 14 cm in length with mean of 7.3 cm. Fistula were found among malignant esophageal stenosis in 6 cases. According to the dysphagia scores, 12 cases were designated at I grade, 31 with II, and 14 with III. 46 cases of malignancy were undertaken radiation therapy combined with transcatheter arterial chemotherapy from 15 to 30 days after stent placement. Results: 62 stents were placed in 57 cases (52 domestic stents, 10 Boston ultraflex), including 4 cases with 2 stents being once placed, 1 case with second time stent placement because of restenosis 4 month later. All stents were placed successfully without serious complications, such as esophageal perforation, massive hemorrhage. 5 cases of cardiac achalasia and 6 cases of benign esophageal stricture are still alive now. The survival rates of 6, 12, 24 and 36 months in 46 malignant cases, were 67.4%(31/46), 43.5%(20/46), 26.1%(12/46), and 19.6(9/46) respectively. Dysphagia were relieved significantly from 7 to 15 days after stent placement. Conclusions: Esophageal stent placement combined with radiation therapy and transcatheter arterial chemotherapy could improve patient life qualities and survival rates significantly in malignant stricture. The effects on benign esophageal stricture by stent placement are comparable with that of surgical treatment

  4. Dual-Source CT Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Michael Köhler

    2011-01-01

    Full Text Available Purpose. To test different peripheral arterial stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation and image noise in dual-source multidetector row CT (DSCT in vitro. Methods and Materials. 22 stents (nitinol, steel, cobalt-alloy, tantalum, platinum alloy were examined in a vessel phantom. All stents were imaged in axial orientation with standard parameters. Image reconstructions were obtained with four different convolution kernels. To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density and noise were measured. Results. The mean percentage of the visible stent lumen diameter from the nominal stent diameter was 74.5% ± 5.7 for the medium-sharp kernel, 72.8% ± 6.4 for the medium, 70.8% ± 6.4 for the medium-smooth and 67.6% ± 6.6 for the smooth kernel. Mean values of lumen attenuation were 299.7HU ± 127 (medium-sharp, 273.9HU ± 68 (medium, 270.7HU ± 53 (medium-smooth and 265.8HU ± 43. Mean image noise was: 54.6 ± 6.3, 20.5 ± 1.7, 16.3 ± 1.7, 14.0 ± 2 respectively. Conclusion. Visible stent lumen diameter varies depending on stent type and scan parameters. Lumen diameter visibility increases with the sharpness of the reconstruction kernel. Smoother kernels provide more realistic density measurements inside the stent lumen and less image noise.

  5. Renal Artery Stenosis in Patients with Resistant Hypertension: Stent It or Not?

    Science.gov (United States)

    Van der Niepen, Patricia; Rossignol, Patrick; Lengelé, Jean-Philippe; Berra, Elena; Sarafidis, Pantelis; Persu, Alexandre

    2017-01-01

    After three large neutral trials in which renal artery revascularization failed to reduce cardiovascular and renal morbidity and mortality, renal artery stenting became a therapeutic taboo. However, this is probably unjustified as these trials have important limitations and excluded patients most likely to benefit from revascularization. In particular, patients with severe hypertension were often excluded and resistant hypertension was either poorly described or not conform to the current definition. Effective pharmacological combination treatment can control blood pressure in most patients with renovascular hypertension. However, it may also induce further renal hypoperfusion and thus accelerate progressive loss of renal tissue. Furthermore, case reports of patients with resistant hypertension showing substantial blood pressure improvement after successful revascularization are published over again. To identify those patients who would definitely respond to renal artery stenting, properly designed randomized clinical trials are definitely needed.

  6. Diagnostic efficacy for coronary in-stent patency with parameters defined on Hounsfield CT value-spatial profile curves

    International Nuclear Information System (INIS)

    Yamazaki, Tadashi; Suzuki, Jun-ichi; Shimamoto, Ryoichi; Tsuji, Taeko; Ohmoto-Sekine, Yuki; Morita, Toshihiro; Yamashita, Hiroshi; Honye, Junko; Nagai, Ryozo; Komatsu, Shuhei; Akahane, Masaaki; Ohtomo, Kuni

    2008-01-01

    Purpose: Hounsfield CT values across coronary CT angiograms constitute CT value-spatial profile curves. These CT profile curves are independent of window settings, and therefore, parameters derived from the curves can be used for objective anatomic analyses. Applicability of parameters derived from the curves to quantification of coronary in-stent patency has not yet been evaluated. Methods: Twenty-five CT value-spatial profile curves were delineated from 10 consecutive coronary stents to test correlation between the curve derived parameter (i.e., the minimum extreme value normalized by dividing by the maximum value of the curves obtained at neighboring outside of stents) and three intravascular ultrasound (IVUS) parameters. Results: Correlation coefficients between normalized minimum extreme value of CT value-spatial profile curves and three IVUS parameters (such as patent cross-sectional in-stent area, the percentage of patent cross-sectional in-stent area, and coronary artery intra-stent diameter) were 0.65 (p < 0.01), 0.44 (p < 0.05) and 0.51 (p < 0.05), respectively. Conclusions: CT parameters defined on Hounsfield CT value-spatial profile curves correlated significantly with IVUS parameters for quantitative coronary in-stent patency. A new approach with CT coronary angiography is therefore indicated for the noninvasive assessment of in-stent re-stenosis

  7. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    International Nuclear Information System (INIS)

    Huet, Nicolas; Rodiere, Mathieu; Badet, Michel; Michoud, Marie; Brichon, Pierre-Yves; Ferretti, Gilbert; Thony, Frédéric

    2016-01-01

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  8. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    Energy Technology Data Exchange (ETDEWEB)

    Huet, Nicolas, E-mail: nhuet@chu-grenoble.fr; Rodiere, Mathieu, E-mail: mrodiere@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France); Badet, Michel, E-mail: michel.badet@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, site de Chambéry, Intensive Care Unit (France); Michoud, Marie, E-mail: marie.michoud@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, Site de Chambéry, Department of Radiology (France); Brichon, Pierre-Yves, E-mail: pybrichon@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Thoracic and Vascular Surgery (France); Ferretti, Gilbert, E-mail: gferretti@chu-grenoble.fr; Thony, Frédéric, E-mail: fthony@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France)

    2016-05-15

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  9. Technological Advances in Stent Therapies: a Year in Review.

    Science.gov (United States)

    Raffoul, Jad; Nasir, Ammar; Klein, Andrew J P

    2018-04-07

    Stent technology has rapidly evolved since the first stainless steel bare metal stents with substantial developments in scaffolding, polymer, drug choice, drug delivery, and elution mechanisms. Most recently, there has been the evolution of bioabsorbable vascular scaffolds, potentially eliminating the need for long-term foreign object retention. These rapid developments have led to an ever-expanding selection of new stents, making the choice of which to use in which patient challenging. Operators must balance potential short- and long-term clinical ramifications, namely stent thrombosis, in-stent restenosis, target lesion revascularization, and target lesion failure. In this review, we hope to provide insight for interventional cardiologists on the details of stent technology and how this impacts outcomes, stent selection, and duration of dual-antiplatelet therapy duration post drug-eluting stent implantation.

  10. Mesh-covered (Roadsaver stent as a new treatment modality for symptomatic or high-risk carotid stenosis

    Directory of Open Access Journals (Sweden)

    Roman Machnik

    2017-05-01

    Full Text Available Introduction : Prevention of periprocedural stroke has a crucial role in carotid artery stenting (CAS procedures. Aim : To assess retrospectively 30-day safety and effectiveness of 41 procedures of internal and common carotid artery stenting using the Roadsaver double nitinol layer micromesh stent in 40 non-consecutive patients with symptomatic or high-risk carotid artery stenosis. Material and methods : The patients were men (n = 31 and women (n = 9; mean age was 67.8 ±7.9 years. Femoral access was used in 39 cases, whereas radial access was used in 2. Proximal (n = 27 or distal (n = 14 embolic neuroprotection was used. Results : The Roadsaver stents (nominal diameter 7, 8 or 9 mm, length 25 or 30 mm were implanted successfully in all cases. One minor stroke occurred after common carotid artery intubation with a guiding catheter (before stent deployment and one transient postprocedural ischemic attack (TIA of the ipsilateral cerebral hemisphere was observed. Internal/common carotid artery stenosis severity was evaluated by duplex Doppler. Maximal peak systolic velocity (PSV before CAS was in the range: 2.0–7.0 m/s, mean: 3.9 ±1.0 m/s, at 24–48 h after stenting mean PSV was 1.1 ±0.4 m/s (p < 0.05, and at 30 days 1.1 ±0.3 m/s (p < 0.05. Maximal end-diastolic velocity (EDV was 0.85–3.5 m/s, mean 1.4 ±0.5 m/s, at 24–48 h after stenting mean EDV was 0.3 ±0.1 m/s (p < 0.05, and at 30 days 0.4 ±0.1 m/s (p < 0.05. No restenosis or thrombosis was observed. Angiographic stenosis decreased from 82.9 ±9.1% (range: 61–97% to 19.3 ±7.3% (range: 0–34% (p < 0.05. Conclusions : The CAS using the Roadsaver stent seems to be safe and effective. Further studies involving larger patient populations and longer follow-up are needed.

  11. Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model

    International Nuclear Information System (INIS)

    Kurz, P.; Stampfl, U.; Christoph, P.; Henn, C.; Satzl, S.; Radeleff, B.; Berger, I.; Richter, G. M.

    2011-01-01

    Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% ± 8.43% at 12 weeks in BNS versus 39.77% ± 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 ± 1.17 versus 2.17 ± 0.85 in BNS. The results for vessel wall injury (0.6 ± 0.58 for Polyzene-F-coated stents; 0.72 ± 0.98 for BNS) and re-endothelialization, (1.16 ± 0.43 and 1.23 ± 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies (≥120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.

  12. Preliminary clinical application in the cranial internal carotid artery of covered stents specially designed for intracranial vasculature

    International Nuclear Information System (INIS)

    Li Minghua; Luo Qiyi; Fang Chun; Xie Zhiyong; Cheng Yingsheng; Gao Bulang; Li Yu; Zhang Beilei; Xie Jian; Wang Yongli

    2007-01-01

    Objective: To investigate the flexibility of both the covered stents specially designed for use in intracranial vasculature and the delivering system in passing through the bone tube and the physiological curves of the cranial internal carotid artery (CICA) to reach the targeted area, the performance (adherence) of the covered stents in occluding vascular wall diseases and the impact on the vascular branches of the covered segment. Methods: The covered stents specially designed for use in intracranial vasculature were used to treat 13 patients with CICA diseases using endovascular techniques. There were 4 huge pseudoaneurysms, 4 giant aneurysms, 3 small wide-necked aneurysms, 1 giant pseudoaneurysm with concurrent internal carotid cavernous fistula (CCF), and 1 CCF. Prior to the detachment of the covered stents, balloon occlusion test (BOT) of the internal carotid artery on the diseased side and whole-brain digital subtraction angiography (DSA) were performed in all the patients. Three to 16 months following procedure, DSA and clinical follow-ups were performed. Results: Thirteen patients all tolerated the BOT well with the DSA demonstrating well-opened anterior and posterior communicating arteries. The covered stents and the delivering systems all successfully passed CICA to reach the targeted diseased area, with the diseased segments of the internal carotid artery including C3-C4 in 4 cases, C4-C5 in 4 and C6-C7 in 5. Immediately following the detachment of the covered stents, DSA demonstrated that 7 aneurysms were completely occluded, 4 aneurysms had slight endoleak, and 1 CCF had markedly-decreased blood flow through the fistula. In the patient with concurrent pseudoaneurysm and CCF, the pseudoaneurysm disappeared and the blood flow through the fistula was markedly-reduced immediately following the stenting procedure. Apart from one patient with aneurysmal subarachnoid hemorrhage who died due to extensive vascular spasm on the 9th day following the stenting

  13. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  14. Orbital atherectomy as an adjunct to debulk difficult calcified lesions prior to mesenteric artery stenting.

    Science.gov (United States)

    Manunga, Jesse M; Oderich, Gustavo S

    2012-08-01

    To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.

  15. Renal artery entrapment by the diaphragmatic crus

    International Nuclear Information System (INIS)

    Thony, F.; Baguet, J.-P.; Rodiere, M.; Sessa, C.; Janbon, B; Ferretti, G.

    2005-01-01

    The aim of this study is to describe renal artery entrapment (RAE) by the diaphragmatic crus and to elucidate the diagnostic and therapeutic approach to this entity. From 1995 to 2002, 15 patients (mean age 65) were found to have a RAE. They were investigated by CT scan (n=14) and/or MRA (n=2) for hypertension (n=7), chronic renal insufficiency (n=4) or aneurysms (n=4). The right (n=11) or the left (n=4) renal artery (RA) was involved. The compression was ostial (n=8) or truncal (n=7), and was ≥50% in eight cases. The course of the RA along the aorta on angiographic views (n=8) or a concentric ostial stenosis in a patient free of atheromatous lesions (n=7) were two findings suggestive of an RAE. Seven RAEs were indicated for treatment but only three were treated, by mean of stenting. Among the latter, two stents were patent at 6-month follow-up and one evolved to restenosis because of a stent fracture. RAEs may be suspected on angiographic views and proved by cross-sectional imaging because of specific imaging features. It is of importance to detect this etiology of RA stenosis because angioplasty with stenting is probably not always advisable. (orig.)

  16. Clinical evaluation of domestic biodegradable drug-eluting stents in the treatment of coronary heart disease

    International Nuclear Information System (INIS)

    Yu Hongying; Suo Chuantao; Shang Ruiping

    2009-01-01

    Objective: To evaluate the safety and efficacy of domestic biodegradable drug-eluting stent, EXCEL, in clinical treatment of coronary heart disease. Methods: During the period of Jan. 2008-Oct. 2008, 100 patients with coronary heart disease who consented to PCI and postoperative coronary angiography were selected and enrolled in the study. The patients were divided into EXCEL group (n = 58) and Cypher group (n = 42). The immediate successful rate of interventional therapy and the complications occurred during hospitalization were observed. Postoperative follow-up and checkup coronary angiography were conducted. Results: No significant difference in the relevant clinical data, in the number and type of diseased coronary branch and in the mean length of implanted stents existed between two groups. Also, no statistically significant difference in the occurrence of major adverse cardiac event (MACE), in-stent restenosis and thrombosis was present between two groups. Conclusion: Compared with Cypher stenting, EXCEL stenting carries similar, i.e. rather low, occurrence of MACE and in-stent restenosis. (authors)

  17. Wingspan stent for symptomatic M1 stenosis of middle cerebral artery

    International Nuclear Information System (INIS)

    Guo Xinbin; Ma Nan; Hu Xiaobo; Guan Sheng; Fan Yimu

    2011-01-01

    Objective: Stent placement for intracranial atherosclerotic stenosis has become an alternative treatment technique; however, stent placement for middle cerebral artery (MCA) stenosis remains a technical and clinical challenge. Our purpose was to assess the safety and feasibility of Wingspan stent for patients with symptomatic M1 stenosis, and its initial effect on prevention of ischemic events. Methods: Fifty-three cases with recurrent symptomatic MCA stenosis resistant to medical therapy treated by self-expanding stent were reviewed retrospectively (average 58 ± 18.5 years old, 19 women). All patients underwent angioplasty and stenting with the Gateway balloon–Wingspan stent system, and advised follow-up with DSA or TCD at 6th month. Results: Patients had an average stenosis ratio of 76.5 ± 15.4% prior to the treatment. Of the 53 patients, the technical success rate was 98.1% as a whole (52/53). The mean degree of stenosis reduced from (76.5 ± 15.4)% to (18.2 ± 11.3)%. Complications associated with the procedure include subarachnoid hemorrhage (1.89%) and occlusion (3.78%) occurred. During a follow-up of 6 months, there was no recurrence of transient ischemic attack or stroke in 52 cases with successful stenting. Cerebral hemodynamics of MCA using transcranial Doppler monitoring were at normal level (<120 cm/s) in 41 follow-up patients. The follow up angiography at 6 month post-procedure was conducted in 32 patients and showed good patency in stented vessels. Conclusions: Wingspan stent for symptomatic stenosis of middle cerebral artery is a safe and feasible procedure. It improves clinical outcome in the intermediate follow up, but its long-term effect remains to be further evaluated.

  18. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov

    2012-01-01

    Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case...... report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While...... the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor....

  19. Carotid Artery Stenting in a Patient with Spontaneous Recanalization of a Proximal Internal Carotid Artery Occlusion: a Case Report

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Koh, Jun Seok; Choi, Woo Suk

    2006-01-01

    We report here on a rare case of carotid artery angioplasty and stenting in a patient with spontaneous recanalization after complete occlusion of the proximal internal carotid artery (ICA). The patient initially showed severe stenosis at the left proximal ICA on MR angiography (MRA). Digital subtraction angiography (DSA) performed three days after MRA showed complete occlusion of the proximal ICA. The follow-up DSA after four weeks showed recanalization of the ICA, and then carotid artery stenting was successfully performed. There has been no neurologic complication during more than one year follow-up. cute internal carotid artery (ICA) occlusions may result in profound disability and death (1). An occluded ICA can spontaneously recanalize, but this doesn't happen frequently, and the natural course of a proximal ICA occlusion and its possibility of recanalization, including the exact time of recanalization after occlusion, are not well known (2, 3). A few studies have reported the incidence of spontaneous recanalization of the proximal internal carotid artery, which has mostly occurred in patients with ICA dissections (4 6). A few limited studies have reported a considerable incidence of spontaneous recanalization in patients with underlying atherosclerotic lesion or atherothombotic diseases (2). The possibility of repeated occlusion and repeated cerebral ischemic infarction may exist for the patients exhibiting spontaneous recanalization of the ICA and underlying atherosclerosis. We report here on a case of carotid artery stenting (CAS) in a patient who exhibited underlying atherosclerosis with spontaneous recanalization after complete occlusion of the proximal ICA

  20. Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction

    International Nuclear Information System (INIS)

    Wang Zhongmin; Chen Kemin; Gong Ju; Zheng Yunfeng; Wang Tianxiang

    2009-01-01

    Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival time between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4

  1. Gianturco metallic biliary stent in malignant biliary obstruction: results of follow-up in dead patients

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Kim, Chan Soo; Lee, Kyung Soo; Choi, See Sung; Won, Jong Jin; Kim, Haak Cheul; Chae, Kwon Mook [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1994-04-15

    In order to study the patency, restenosis, efficacy, and complication of the metallic stent in the course of treatment of malignant biliary obstruction, the results of follow up of the dead patients after stent insertion were reviewed. Self-expandable Gianturco metallic stent with 10-mm diameter was successfully inserted in 33 patients: 10 with Klatskin tumor, 7 with common bile duct cancer, 7 with gallbladder cancer, 5 with pancreatic cancer, 2 with recurred stomach cancer, one with periampullary cancer, one with hepatocellular carcinoma. The overall duration of survival and patency of the stents in 33 patients were 5.2 months(1-12 months) and 4.9 months(1-14 months), respectively. Restenosis of metallic stents was found in 9 cases(27%), after 6.1 months in average. Causes of stent occlusion were overgrowing of tumor in 5, overgrowing and ingrowing of tumor in 3, extraductal dislodgement in one case. Two cases of symptomatic cholangitis after stent placement were successfully treated with percutaneous cholecystostomy. Three cases of destruction and migration of metallic stents were found after 6 months. On the basis of our experience, insertion of Gianturco metallic biliary stent is an acceptable treatment method in the malignant biliary obstruction, especially for whom short term survival is expected.

  2. Pulmonary arterial stent implantation in an adult with Williams syndrome

    NARCIS (Netherlands)

    Reesink, Herre J.; Henneman, Onno D. F.; van Delden, Otto M.; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul

    2007-01-01

    We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent

  3. Carotid Artery Stenting Successfully Prevents Progressive Stroke Due to Mobile Plaque

    Directory of Open Access Journals (Sweden)

    Masahiro Oomura

    2015-05-01

    Full Text Available We report a case of progressive ischemic stroke due to a mobile plaque, in which carotid artery stenting successfully prevented further infarctions. A 78-year-old man developed acute multiple infarcts in the right hemisphere, and a duplex ultrasound showed a mobile plaque involving the bifurcation of the left common carotid artery. Maximal medical therapy failed to prevent further infarcts, and the number of infarcts increased with his neurological deterioration. Our present case suggests that the deployment of a closed-cell stent is effective to prevent the progression of the ischemic stroke due to the mobile plaque.

  4. Evolution of patency rates of self-expandable bare metal stents for endovascular treatment of femoro-popliteal arterial occlusive disease: Does stent design matter?

    Science.gov (United States)

    Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus

    2017-09-01

    To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.

  5. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  6. New developments in the clinical use of drug-coated balloon catheters in peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Naghi J

    2016-06-01

    Full Text Available Jesse Naghi, Ethan A Yalvac, Ali Pourdjabbar, Lawrence Ang, John Bahadorani, Ryan R Reeves, Ehtisham Mahmud, Mitul Patel Division of Cardiovascular Medicine, Sulpizio Cardiovascular Center, University of California, San Diego, CA, USA Abstract: Peripheral arterial disease (PAD involving the lower extremity is a major source of morbidity and mortality. Clinical manifestations of PAD span the spectrum from lifestyle limiting claudication to ulceration and gangrene leading to amputation. Advancements including balloon angioplasty, self-expanding stents, drug-eluting stents, and atherectomy have resulted in high technical success rates for endovascular therapy in patients with PAD. However, these advances have been limited by somewhat high rates of clinical restenosis and clinically driven target lesion revascularization. The recent introduction of drug-coated balloon technology shows promise in limiting neointimal hyperplasia induced by vascular injury after endovascular therapies. This review summarizes the contemporary clinical data in the emerging area of drug-coated balloons. Keywords: drug-coated balloons, endovascular, percutaneous transluminal angioplasty, paclitaxel, peripheral arterial disease

  7. High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

    International Nuclear Information System (INIS)

    Rist, Carsten; Nikolaou, Konstantin; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.; Flohr, Thomas

    2006-01-01

    The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen. (orig.)

  8. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  9. Efficacy of Carotid Artery Stenting by the Universal Protection Method.

    Science.gov (United States)

    Goto, Shunsaku; Ohshima, Tomotaka; Kato, Kyozo; Izumi, Takashi; Wakabayashi, Toshihiko

    2018-04-18

    To avoid distal plaques embolization during carotid artery stenting, we developed Universal Protection Method that combined the use of a proximal common carotid artery balloon, an external carotid artery balloon, and a distal internal carotid artery filter, with continuous flow reversal to the femoral vein. Herein, we assessed the efficacy of the Universal Protection Method by comparing stenting outcomes before and after its introduction. We assessed outcomes for 115 cases before and 41 cases after the Universal Protection Method was adopted (non-Universal Protection Method and Universal Protection Method groups, respectively). We then compared procedure details, magnetic resonance imaging (within 48 hours after the procedure), intraprocedural complications, and postoperative stroke rates. Ischemic stroke was not observed in the Universal Protection Method group, but 1 major stroke and 2 minor strokes were observed in the non-Universal Protection Method group. High-intensity areas were seen in 6 (15.0%) and 49 (42.6%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively (P = .001). Contrastingly, intraprocedural complications were observed in 9 (22.5%) and 21 (18.3%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively. Among these intraprocedural complication cases, high-intensity areas were observed in 1 case (11.1%) in the Universal Protection Method group and in 15 cases (71.4%) in the non-Universal Protection Method group. Universal Protection Method is a safe technique that is applicable to all patients undergoing carotid artery stenting, irrespective of individual risk factors. Notably, the incidence rates of both distal embolization and unexpected intraprocedural complications are low. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  10. Critical appraisal of paclitaxel balloon angioplasty for femoral-popliteal arterial disease.

    Science.gov (United States)

    Herten, Monika; Torsello, Giovanni B; Schönefeld, Eva; Stahlhoff, Stefan

    2016-01-01

    Peripheral arterial disease, particularly critical limb ischemia, is an area with urgent need for optimized therapies because, to date, vascular interventions often have limited life spans. In spite of initial encouraging technical success after femoropopliteal percutaneous transluminal angioplasty or stenting, postprocedural restenosis remains the major problem. The challenging idea behind the drug-coated balloon (DCB) concept is the biological modification of the injury response after balloon dilatation. Antiproliferative drugs administered via DCBs or drug-eluting stents are able to suppress neointimal hyperplasia, the main cause of restenosis. This article reviews the results of DCB treatments of femoropopliteal and infrapopliteal lesions in comparison to standard angioplasty with uncoated balloons. A systematic literature search was performed in 1) medical journals (ie, MEDLINE), 2) international registers for clinical studies (ie, www.clinicaltrials.gov), and 3) abstracts of scientific sessions. Several controlled randomized trials with follow-up periods of up to 5 years demonstrated the efficacy of paclitaxel -DCB technology. However, calcified lesions seem to affect the efficacy of DCB. Combinations of preconditioning methods with DCBs showed promising results. Although the mechanical abrasion of calcium via atherectomy or laser ablation showed favorable periprocedural results, the long-term impact on restenosis and clinical outcome has to be demonstrated. Major advantages of the DCBs are the rapid delivery of drug at uniform concentrations with a single dose, their efficacy in areas wherein stents have been contraindicated until now (ie, bifurcation, ostial lesions), and in leaving no stent scaffold behind. Reinterventions are easier to perform because DCBs leave no metal behind. Various combinations of DCBs with other treatment modalities may prove to be viable options in future. The follow-up results of clinical studies will evaluate the long-term impact

  11. Comparison of zotarolimus-eluting and everolimus-eluting coronary stents

    DEFF Research Database (Denmark)

    Serruys, Patrick W; Silber, Sigmund; Garg, Scot

    2010-01-01

    New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed...

  12. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2010-03-20

    Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy.

  13. Life-threatening bleeding from a vertebral artery pseudoaneurysm after anterior cervical spine approach: endovascular repair by a triple stent-in-stent method. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Alzamora, M.G.; Klisch, J. [Section of Neuroradiology, Neurocenter, University of Freiburg (Germany); Rosahl, S.K.; Lehmberg, J. [Department of Neurosurgery, Neurocenter, University of Freiburg (Germany)

    2005-04-01

    The incidence of injury to the cervical vertebral artery during surgery for stenosis of the cervical neuroforamina is very low. We present a case in which bleeding during microforaminotomy at the level C6/7 occurred. The bleeding could be controlled intraoperatively. Two days later, a life-threatening cervical hematoma required urgent bedside evacuation. A false aneurysm of the left cervical vertebral artery was successfully occluded by a modified triple stent-in-stent technique, maintaining the flow in the vessel.

  14. Life-threatening bleeding from a vertebral artery pseudoaneurysm after anterior cervical spine approach: endovascular repair by a triple stent-in-stent method. Case report

    International Nuclear Information System (INIS)

    Alzamora, M.G.; Klisch, J.; Rosahl, S.K.; Lehmberg, J.

    2005-01-01

    The incidence of injury to the cervical vertebral artery during surgery for stenosis of the cervical neuroforamina is very low. We present a case in which bleeding during microforaminotomy at the level C6/7 occurred. The bleeding could be controlled intraoperatively. Two days later, a life-threatening cervical hematoma required urgent bedside evacuation. A false aneurysm of the left cervical vertebral artery was successfully occluded by a modified triple stent-in-stent technique, maintaining the flow in the vessel

  15. Differences in patient selection and outcomes between SilverHawk atherectomy and laser ablation in the treatment of femoropopliteal in-stent restenosis: a retrospective analysis from a single center.

    Science.gov (United States)

    Shammas, Nicolas W; Shammas, Gail A; Jerin, Michael

    2013-12-01

    To analyze differences in the application and outcomes of SilverHawk atherectomy (SH) and excimer laser ablation (ELA) in the treatment of femoropopliteal in-stent restenosis (ISR) in an unselected cohort of patients treated at a single center. Between January 2005 and June 2010, 81 consecutive patients (46 men; mean age 69.1 years, range 43-86) underwent directional atherectomy (41 SH, 40 ELA) for femoropopliteal ISR lesions. Data were reviewed retrospectively on procedural outcomes, major adverse events, and 1-year target lesion revascularization (TLR) obtained from medical records and supplemented with telephone calls. The primary endpoint was symptom-driven TLR at 1 year; secondary endpoints were death and amputation. ELA was utilized more frequently than SH in longer lesions (210.4±104 vs. 126.2±79.3 mm, respectively; p=0.001), subacute presentation (55% vs. 14.6%, p=0.001), TASC D lesions (47.5% vs. 12.2%), and in patients with more angiographic thrombus (42.5% vs. 4.9%, p=0.001). Final angiographic success (<30% residual narrowing post final treatment) was similar between ELA and SH (92.5% vs. 100%, respectively, p=0.12). Bailout stenting was significantly higher with ELA vs. SH (50.0% vs. 24.4%, p=0.022). At 1 year, TLR had occurred in 48.7% of the ELA patients vs. 31.7% of the SH cases (p=0.171). Regression analysis confirmed that SH was a predictor of TLR at 1 year (hazard ratio 2.679, 95% CI 1.015 to 7.073, p=0.047). Both SH and ELA continue to have a high TLR rate in treating ISR of the femoral and popliteal arteries. A higher rate of delayed failure is seen with SH and an earlier, steeper loss of TLR-free survival is seen with ELA.

  16. Interventional Management of Delayed and Massive Hemobilia due to Arterial Erosion by Metallic Biliary Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hee Seok [Dept. of Radiology, Gyeongsang National University Hospital, Jinju (Korea, Republic of); Shin, Tae Beom [Dept. of Diagnostic Radiology, Kimhae Jung Ang Hospital, Kimhae (Korea, Republic of); Hwang, Jae Cheol [Dept. of Radiology, Ulsan Hospital, Ulsan (Korea, Republic of); Bae, Jae Ik [Dept. of Radiology, Ajou University Hospital, Suwon (Korea, Republic of); Kim, Chang Won [Dept. of Radiology, Busan National University Hospital, Busan (Korea, Republic of)

    2012-01-15

    To evaluate the effectiveness of interventional management for delayed and massive hemobilia secondary to arterial erosion self expandable metallic stent (SES) in with biliary duct malignancy. Over 8-year period, eight patients who suffered from delayed massive hemobilia after SES placement for malignant biliary obstruction as palliative procedure, were included. The mean period between SES placement and presence of massive gastrointestinal hemorrhage was 66.5 days (15-152 days), pancreatic cancer (n = 2), Klatskin tumor (n = 2), common bile duct cancer (n = 2), intrahepatic cholangiocarcinoma (n = 1), and gastric cancer with ductal invasion (n = 1). Angiographic findings were pseudoaneurysm (n = 6), contrast extravasation (n = 1) and arterial spasm at segment (n = 1). Six patients underwent embolization of injured vessels using microcoils and N-butyl cyanoacrylate. Two patients underwent stent graft placement at right hepatic artery to prevent ischemic hepatic damage because of the presence of portal vein occlusion. Massive hemobilia was successfully controlled by the embolization of arteries (n = 6) and stent graft placement (n = 2) without related complications. The delayed massive hemobilia to arterial erosion metallic biliary stent is rare this complication be successfully treated by interventional management.

  17. Cardiological-interventional therapy of coronary artery disease today

    International Nuclear Information System (INIS)

    Reynen, K.; Henssge, R.

    1999-01-01

    The current importance of the interventional therapy of coronary artery disease may be deduced from the exponential increase in procedures performed in Germany in the last decade - at least 125,840 in 1996. Today, by improved catheter and balloon materials as well as by growing experience of the cardiologists, even complex lesions may be treated. Limitations of balloon angioplasty include acute vessel closure and restenosis - newer angioplasty devices like directional or rotational atherectomy or excimer-laser angioplasty did not overcome these limitations; only by coronary stenting, acute vessel closure could be managed and the likelihood of restenosis - at least in particular groups of patients - could be reduced. For a few years, intracoronary brachytherapy of the segments dilated with beta- or gamma-emitters has been seeking to reduce restenosis rate; the department of cardiology of the Dresden Cardiovascular Institute is participating in such a multicentre study using the beta-emitter 188 renium. Further main topics of our department represent primary angioplasty in patients with acute myocardial infarction and invasive diagnostic or interventional procedures by the transradial approach. (orig.)

  18. Percutaneous treatment of transplant renal artery stenosis in children.

    Science.gov (United States)

    Repetto, Horacio A; Rodríguez-Rilo, Laila; Mendaro, Esteban; Basso, Laura; Galvez, Hugo; Morrone, Gabriela; Vazquez, Luis A

    2004-12-01

    Percutaneous treatment of renal artery stenosis (RAS) is an accepted procedure and numerous reports have been published. However, experience with its use in RAS in the transplanted kidney in children is scarce. Since 1994 we have diagnosed RAS in seven children with the use of Doppler ultrasonography (US), confirming it with percutaneous angiography (PAG). In six of the seven patients percutaneous transluminal angioplasty (PTA) was performed. In one patient a metallic stent was placed due to the extension of the arterial lesion, and a second stent was placed in another child when a re-stenosis was diagnosed 1 month after the PTA. All patients presented with hypertension (de novo or 30% increase over previous values). After ruling out acute rejection, calcineurin inhibitor toxicity, and urinary obstruction, US was performed and, when an increase in arterial flux velocity was registered, PAG was also performed. Six children showed an increase in serum creatinine (Cr) and proteinuria. Blood pressure decreased after the procedure and Cr returned to previous levels in all children. One of the grafts was lost due to chronic transplant rejection 7 years later. The other children have a functioning kidney. Although this is a small group of patients, the consistently good results and the lack of reported experience prompted us to communicate our preliminary observation.

  19. Second generation drug-eluting stents versus bare-metal stents for percutaneous coronary intervention of the proximal left anterior descending artery

    DEFF Research Database (Denmark)

    Mangione, Fernanda Marinho; Biering-Sørensen, Tor; Nochioka, Kotaro

    2017-01-01

    OBJECTIVES: To compare mid-term outcomes between patients undergoing proximal left anterior descending artery (LAD) percutaneous coronary intervention (PCI) with second generation drug-eluting stent (DES) or bare-metal stent (BMS). BACKGROUND: PCI with BMS and first-generation DES have shown to b...

  20. Stent implantation for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation

    International Nuclear Information System (INIS)

    Xing Ming; Yang Pengfei; Huang Qinghai; Zhao Wenyuan; Hong Bo; Xu Yi; Liu Jianmin

    2012-01-01

    Objective: To preliminarily evaluate the feasibility, safety and efficacy of stent placement for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation. Methods: Eleven patients with wide-necked aneurysms located at internal carotid artery bifurcation, who were encountered during the period from Jan. 2004 to Dec. 2010 in hospital, were collected. A total of 16 intracranial aneurysms were detected, of which 11 were wide-necked and were located at internal carotid artery bifurcation. The diameters of the aneurysms ranged from 2.5 mm to 18 mm. Individual stent type and stenting technique was employed for each patient. Follow-up at 1, 3, 6 and 12 months after the procedure was conducted. Results: A total of 11 different stents were successfully deployed in the eleven patients. The stents included balloon expandable stent (n=1) and self-expanding stent (n=10). According to Raymond grading for the immediate occlusion of the aneurysm, grade Ⅰ (complete obliteration) was obtained in 4, grade Ⅱ (residual neck) in 2 and grade Ⅲ (residual aneurysm) in 5 cases. No procedure-related complications occurred. At the time of discharge, the modified Rankin score was 0-1 in the eleven patients. During the follow-up period lasting for 1-108 months, all the patients were in stable condition and no newly-developed neurological dysfunction or bleeding observed. Follow-up examination with angiography (1-48 months) showed that the aneurysms were cured (no visualization) in 4 cases, improved in 2 cases and in stable condition in one case. Conclusion: For the treatment of wide-necked aneurysms located at internal carotid artery bifurcation, stent implantation is clinically feasible, safe and effective. Further studies are required to evaluate its long-term efficacy. (authors)

  1. Dual-artery stenting of a type III single coronary artery from right aortic sinus

    Directory of Open Access Journals (Sweden)

    Shivanad Patil

    2015-12-01

    Full Text Available A single coronary artery presenting with stenosis in two of the three vessels arising from a common ostium is a rare anomaly Lipton et al. proposed a classification, which was modified by Yamanaka and Hobbs. In our case, a single coronary artery was giving rise to the LAD, left circumflex (LCx, and the right coronary artery (RCA. There was 80% stenosis in the ostium of the LCx. The RCA in the mid and distal segment had stenosis of 80% and 70%, respectively. We were able to successfully stent the three stenotic segments.

  2. Predictive value study of serum STIM1 and Adropin contents in cardiovascular events and restenosis after PCI operation

    Directory of Open Access Journals (Sweden)

    Qiu-Wei Lin

    2016-02-01

    Full Text Available Objective: To study the predictive value of serum STIM1 and Adropin contents in cardiovascular events and restenosis after PCI operation. Methods: Single coronary artery lesion patients receiving percutaneous coronary intervention in our hospital from May 2014 to January 2015 were selected for study, 45 cases of patients with in-stent restenosis 6 months after PCI operation more than 50% were enrolled in ISR group, 85 cases of patients with instent restenosis no more than 50% were enrolled in NISR group, and then serum STIM1, Adropin and NO contents as well as endothelial progenitor cell content and endothelial microparticle number in peripheral blood of two groups were detected. Results: Serum STIM1 content of ISR group was significantly higher than that of NISR group and STIM1 content was positively correlated with lumen stenosis degree, and serum Adropin content of ISR group was significantly lower than that of NISR group and Adropin content was negatively correlated with lumen stenosis degree; endothelial progenitor cell content in peripheral blood and serum NO content of ISR group were less than those of NISR group, and endothelial microparticle number in peripheral blood was more than that of NISR group; serum STIM1 content was positively correlated with endothelial microparticle number in peripheral blood and negatively correlated with endothelial progenitor cell content in peripheral blood, and serum Adropin content was negatively correlated with endothelial microparticle number in peripheral blood and positively correlated with serum NO content. Conclusion: Serum STIM1 content increase and Adropin content decrease are related to the occurrence of cardiovascular events and restenosis after PCI operation, and the two molecules mainly affect endothelial cell function and endothelial progenitor cell homing.

  3. Acute Carotid Artery Stent Thrombosis Due to Dual Antiplatelet Resistance

    International Nuclear Information System (INIS)

    Köklü, Erkan; Arslan, Şakir; Yüksel, İsa Öner; Bayar, Nermin; Koç, Pınar

    2015-01-01

    Carotid artery stenting (CAS) is a revascularization modality that is an alternative to carotid endarterectomy. The efficacy of CAS in primary and secondary prevention from ischemic stroke has been demonstrated in various trials. Acute thrombosis of CAS is a rare complication that can lead to dramatic and catastrophic consequences. We discuss a case of acute CAS thrombosis in a patient who had previously undergone successful CAS. CAS was performed in a 73-year-old man who had had dysarthria lasting 2 weeks with 95 % stenosis in his left internal carotid artery. An acute cerebrovascular event resulting in right-sided hemiplegia developed 24 h after the procedure. Computed tomographic carotid angiography revealed complete occlusion of the stent with thrombus. The cause of stent thrombosis was thought to be antiaggregant resistance to both acetylsalicylic acid and clopidogrel. The most important cause of acute CAS thrombosis is inadequate or ineffective antiaggregant therapy. Evaluating patients who are candidates for CAS for acetylsalicylic acid and clopidogrel resistance may preclude this complication

  4. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na [Chonnam Univ. College of Medicine, Kwangju (Korea, Republic of)

    1999-04-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate.

  5. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    International Nuclear Information System (INIS)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na

    1999-01-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate

  6. Impact of stent strut design in metallic stents and biodegradable scaffolds.

    Science.gov (United States)

    Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip

    2014-12-20

    Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. In vitro imaging of coronary artery stents: Are there differences between 16- and 64-slice CT scanners?

    International Nuclear Information System (INIS)

    Wolf, Florian; Feuchtner, Gudrun M.; Homolka, Peter; Langenberger, Herbert; Stadler, Alfred; Bader, Till R.; Weber, Michael; Lammer, Johannes; Loewe, Christian

    2008-01-01

    Purpose: To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents. Methods and materials: Twelve different coronary artery stents were placed in the drillings of a combined heart and chest phantom, which was scanned with a 16- and 64-slice CT scanner. Coronal reformations were evaluated for artificial lumen narrowing, intraluminal attenuation values, and false widening of the outer stent diameter as an indicator of artifacts outside the stent. Results: Mean artificial lumen narrowing was not significantly different between the 16- and 64-slice CT scanner (44% versus 39%; p = 0.408). The differences between the Hounsfield Units (HU) measurements inside and outside the stents were significantly lower (p = 0.001) with 64- compared to 16-slice CT. The standard deviation of the HU measurements inside the stents was significantly (p = 0.002) lower with 64- than with 16-slice CT. Artifacts outside the stents were not significantly different between the scanners (p = 0.866). Conclusion: Visualization of the in-stent lumen is improved with 64-slice CT when compared with 16-slice CT as quantified by significantly lesser intraluminal image noise and less artificial rise in intraluminal HU measurement, which is the most important parameter for the evaluation of stent patency in vivo

  8. Valve-Like and Protruding Calcified Intimal Flap Complicating Common Iliac Arteries Kissing Stenting

    Directory of Open Access Journals (Sweden)

    George S. Georgiadis

    2015-01-01

    Full Text Available Endovascular therapy for iliac artery chronic total occlusions is nowadays associated with low rates of procedure-related complications and improved clinical outcomes, and it is predominantly used as first-line therapy prior to aortobifemoral bypass grafting. Herein, we describe the case of a patient presenting with an ischemic left foot digit ulcer and suffering complex aortoiliac lesions, who received common iliac arteries kissing stents, illustrating at final antegrade and retrograde angiograms the early recognition of a blood flow obstructing valve-like calcified intimal flap protruding through the stent struts, which was obstructing antegrade but not retrograde unilateral iliac arterial axis blood flow. The problem was resolved by reconstructing the aortic bifurcation at a more proximal level. Completion angiogram verified normal patency of aorta and iliac vessels. Additionally, a severe left femoral bifurcation stenosis was also corrected by endarterectomy-arterioplasty with a bovine patch. Postintervention ankle brachial pressure indices were significantly improved. At the 6-month and 2-year follow-up, normal peripheral pulses were still reported without intermittent claudication suggesting the durability of the procedure. Through stent-protruding calcified intimal flap, is a very rare, but existing source of antegrade blood flow obstruction after common iliac arteries kissing stents.

  9. Comparison of Self-Expanding Polyethylene Terephthalate and Metallic Stents Implanted in Porcine Iliac Arteries

    International Nuclear Information System (INIS)

    Wilczek, Krzysztof; Scheerder, Ivan de; Wang Kai; Verbeken, Eric; Piessens, Jan

    1996-01-01

    Purpose: Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). Methods: Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deployment was studied angiographically and with intravascular ultrasound immediately after stent implantation. The angiographic stented lumen diameter was measured using quantitative vessel analysis before, immediately after stenting, and at 6-week follow-up. Cross-section histopathology and area morphometry were performed. Results: Immediately poststenting, intravascular ultrasound revealed proximal dislocation of 5 of the 13 PET stents, whereas all metal stents were firmly embedded at the implantation site. At 6-week follow-up, three of the remaining PET stents were totally or subtotally occluded by organized thrombus, whereas all metal stents were patent. Compared with immediately poststenting, the angiographic lumen diameter within the five remaining PET stents was reduced by 30%, and that of the metallic stents was virtually unaltered (p < 0.02). This observation was confirmed by postmortem morphometry, wherein the PET-stented vessel segments a diameter stenosis of 40% was measured vs only 9% in the metallic stents (p < 0.0001). Conclusion: PET-stent deployment is difficult to control due to the lack of radiopacity of this stent. PET stents seem to be more thrombogenic and lead to significantly more neointimal proliferation than metallic stents

  10. Directional Atherectomy in Iliac Stent Failure: Clinical Technique and Histopathologic Correlation

    International Nuclear Information System (INIS)

    Ettles, Duncan F.; MacDonald, Alastair W.; Burgess, Paul A.; Nicholson, Anthony A.; Dyet, John F.

    1998-01-01

    Purpose: To assess the feasibility and efficacy of directional atherectomy in the treatment of iliac stent stenosis or occlusion and to evaluate the histologic composition of excised atherectomy specimens. Methods: Directional atherectomy of six occluded and 10 severely stenosed iliac stents was undertaken in 12 patients at a mean interval of 28 months (range 3-69 months) after stent insertion for occlusive aortoiliac disease. In cases of stent occlusion, atherectomy was preceded by low-dose thrombolysis. In all patients stent clearance with return of femoral pulses was achieved within 24 hr and there were no significant complications. All excised specimens were sent for histologic examination. Results: Eleven patients (92%) remain symptom free with unlimited walking distance at a mean follow-up interval of 11.5 months (range 3-31 months) after treatment. Histologic examination revealed typical myointimal hyperplasia at three excision sites, intimal fibrosis at three sites, atheroma at four sites and organized thrombus at six sites. Conclusion: Atherectomy offers an effective treatment in iliac stent occlusion and restenosis with no significant adverse effects. Debulking of these lesions seems to offer a more logical approach than simple balloon angioplasty. Clinical and duplex follow-up confirms satisfactory outcome within the first year but longer-term results are not yet known. The histologic data obtained demonstrate that stent restenosis and occlusion are likely to be multifactorial, and challenge the assumption that myointimal hyperplasia is the sole cause of iliac stent occlusion

  11. Imaging arterial cells, atherosclerosis, and restenosis by multimodal nonlinear optical microscopy

    Science.gov (United States)

    Wang, Han-Wei; Simianu, Vlad; Locker, Matthew J.; Sturek, Michael; Cheng, Ji-Xin

    2008-02-01

    By integrating sum-frequency generation (SFG), and two-photon excitation fluorescence (TPEF) on a coherent anti-Stokes Raman scattering (CARS) microscope platform, multimodal nonlinear optical (NLO) imaging of arteries and atherosclerotic lesions was demonstrated. CARS signals arising from CH II-rich membranes allowed visualization of endothelial cells and smooth muscle cells in a carotid artery. Additionally, CARS microscopy allowed vibrational imaging of elastin and collagen fibrils which are rich in CH II bonds in their cross-linking residues. The extracellular matrix organization was further confirmed by TPEF signals arising from elastin's autofluorescence and SFG signals arising from collagen fibrils' non-centrosymmetric structure. The system is capable of identifying different atherosclerotic lesion stages with sub-cellular resolution. The stages of atherosclerosis, such as macrophage infiltration, lipid-laden foam cell accumulation, extracellular lipid distribution, fibrous tissue deposition, plaque establishment, and formation of other complicated lesions could be viewed by our multimodal CARS microscope. Collagen percentages in the region adjacent to coronary artery stents were resolved. High correlation between NLO and histology imaging evidenced the validity of the NLO imaging. The capability of imaging significant components of an arterial wall and distinctive stages of atherosclerosis in a label-free manner suggests the potential application of multimodal nonlinear optical microscopy to monitor the onset and progression of arterial diseases.

  12. Comparison of clinical outcomes after drug-eluting balloon and drug-eluting stent use for in-stent restenosis related acute myocardial infarction: a retrospective study

    Directory of Open Access Journals (Sweden)

    Chih-Yuan Fang

    2018-04-01

    Full Text Available Background Good results of drug-eluting balloon (DEB use are achieved in in-stent restenosis (ISR lesions, small vessel disease, long lesions, and bifurcations. However, few reports exist about DEB use in acute myocardial infarction (AMI with ISR. This study’s aim was to evaluate the efficacy of DEB for AMI with ISR. Methods Between November 2011 and December 2015, 117 consecutive patients experienced AMI including ST-segment elevation MI, and non-ST-segment elevation MI due to ISR, and received percutaneous coronary intervention (PCI. We divided our patients into two groups: (1 PCI with further DEB, and (2 PCI with further drug-eluting stent (DES. Clinical outcomes such as target lesion revascularization, target vessel revascularization, recurrent MI, stroke, cardiovascular mortality, and all-cause mortality were analyzed. Results The patients’ average age was 68.37 ± 11.41 years; 69.2% were male. A total of 75 patients were enrolled in the DEB group, and 42 patients were enrolled in the DES group. The baseline characteristics between the two groups were the same without statistical differences except for gender. Peak levels of cardiac biomarker, pre- and post-PCI cardiac function were similar between two groups. The major adverse cardiac cerebral events rate (34.0% vs. 35.7%; p = 0.688 and cardiovascular mortality rate (11.7% vs. 12.8%; p = 1.000 were similar in both groups. Conclusions DEB is a reasonable strategy for AMI with ISR. Compared with DES, DEB is an alternative strategy which yielded acceptable short-term outcomes and similar 1-year clinical outcomes.

  13. Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease

    DEFF Research Database (Denmark)

    Raungaard, Bent; Christiansen, Evald H; Bøtker, Hans Erik

    2017-01-01

    artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion......OBJECTIVES: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients. BACKGROUND: Biodegradable-polymer biolimus-eluting stents are superior to first......-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking. METHODS: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary...

  14. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, Vimal, E-mail: drvimalmehta@yahoo.co.in; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay [G.B. Pant Institute of Postgraduate Medical Education and Research (India)

    2016-01-15

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory.

  15. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    International Nuclear Information System (INIS)

    Mehta, Vimal; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay

    2016-01-01

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory

  16. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    NARCIS (Netherlands)

    Ederle, J.; Dobson, J.; Featherstone, R.L.; Bonati, L.H.; Worp, H.B. van der; Borst, G.J. de; Lo, T.H.; Gaines, P.; Dorman, P.J.; Macdonald, S.; Lyrer, P.A.; Hendriks, J.M.; McCollum, C.; Nederkoorn, P.J.; Brown, M.M.; Blankensteijn, J.D.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,

    2010-01-01

    BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International

  17. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Jörg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molyneux, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Chan, A.; Chu, P.; Clark, D.; Dewey, H.; Donnan, G.; Fell, G.; Hoare, M.; Molan, M.; Roberts, A.; Roberts, N.; Beiles, B.; Bladin, C.; Clifford, C.; Grigg, M.; New, G.; Bell, R.; Bower, S.; Chong, W.; Holt, M.; Saunder, A.; Than, P. G.; Gett, S.; Leggett, D.; McGahan, T.; Quinn, J.; Ray, M.; Wong, A.; Woodruff, P.; Foreman, R.; Schultz, D.; Scroop, R.; Stanley, B.; Allard, B.; Atkinson, N.; Cambell, W.; Davies, S.; Field, P.; Milne, P.; Mitchell, P.; Tress, B.; Yan, B.; Beasley, A.; Dunbabin, D.; Stary, D.; Walker, S.; Cras, P.; d'Archambeau, O.; Hendriks, J. M. H.; van Schil, P.; St Blasius, A. Z.; Bosiers, M.; Deloose, K.; van Buggenhout, E.; de Letter, J.; Devos, V.; Ghekiere, J.; Vanhooren, G.; Astarci, P.; Hammer, F.; Lacroix, V.; Peeters, A.; Verbist, J.; Blair, J.-F.; Caron, J. L.; Daneault, N.; Giroux, M.-F.; Guilbert, F.; Lanthier, S.; Lebrun, L.-H.; Oliva, V.; Raymond, J.; Roy, D.; Soulez, G.; Weill, A.; Hill, M.; Hu, W.; Hudion, M.; Morrish, W.; Sutherland, G.; Wong, J.; Albäck, A.; Harno, H.; Ijäs, P.; Kaste, M.; Lepäntalo, M.; Mustanoja, S.; Paananen, T.; Porras, M.; Putaala, J.; Railo, M.; Sairanen, T.; Soinne, L.; Vehmas, A.; Vikatmaa, P.; Goertler, M.; Halloul, Z.; Skalej, M.; Brennan, P.; Kelly, C.; Leahy, A.; Moroney, J.; Thornton, J.; Koelemay, M. J. W.; Reekers, J. A. A.; Roos, Y. B. W. E. M.; Hendriks, J. M.; Koudstaal, P. J.; Pattynama, P. M. T.; van der Lugt, A.; van Dijk, L. C.; van Sambeek, M. R. H. M.; van Urk, H.; Verhagen, H. J. M.; Bruijninckx, C. M. A.; de Bruijn, S. F.; Keunen, R.; Knippenberg, B.; Mosch, A.; Treurniet, F.; van Dijk, L.; van Overhagen, H.; Wever, J.; de Beer, F. C.; van den Berg, J. S. P.; van Hasselt, B. A. A. M.; Zeilstra, D. J.; Boiten, J.; van Otterloo, J. C. A. de Mol; de Vries, A. C.; Lycklama a Nijeholt, G. J.; van der Kallen, B. F. W.; Blankensteijn, J. D.; de Leeuw, F. E.; Kool, L. J. Schultze; van der Vliet, J. A.; de Borst, G. J.; de Kort, G. A. P.; Kapelle, L. J.; Lo, T. H.; Mali, W. P. Th M.; Moll, F.; van der Worp, H. B.; Verhagen, H.; Barber, P. A.; Bourchier, R.; Hill, A.; Holden, A.; Stewart, J.; Bakke, S. J.; Krohg-Sørensen, K.; Skjelland, M.; Tennøe, B.; Bialek, P.; Biejat, Z.; Czepiel, W.; Czlonkowska, A.; Dowzenko, A.; Jedrzejewska, J.; Kobayashi, A.; Lelek, M.; Polanski, J.; Kirbis, J.; Milosevic, Z.; Zvan, B.; Blasco, J.; Chamorro, A.; Macho, J.; Obach, V.; Riambau, V.; San Roman, L.; Branera, J.; Canovas, D.; Estela, Jordi; Gaibar, A. Gimenez; Perendreu, J.; Björses, K.; Gottsater, A.; Ivancev, K.; Maetzsch, T.; Sonesson, B.; Berg, B.; Delle, M.; Formgren, J.; Gillgren, P.; Kall, T.-B.; Konrad, P.; Nyman, N.; Takolander, R.; Andersson, T.; Malmstedt, J.; Soderman, M.; Wahlgren, C.; Wahlgren, N.; Binaghi, S.; Hirt, L.; Michel, P.; Ruchat, P.; Engelter, S. T.; Fluri, F.; Guerke, L.; Jacob, A. L.; Kirsch, E.; Lyrer, P. A.; Radue, E.-W.; Stierli, P.; Wasner, M.; Wetzel, S.; Bonvin, C.; Kalangos, A.; Lovblad, K.; Murith, M.; Ruefenacht, D.; Sztajzel, R.; Higgins, N.; Kirkpatrick, P. J.; Martin, P.; Varty, K.; Adam, D.; Bell, J.; Crowe, P.; Gannon, M.; Henderson, M. J.; Sandler, D.; Shinton, R. A.; Scriven, J. M.; Wilmink, T.; D'Souza, S.; Egun, A.; Guta, R.; Punekar, S.; Seriki, D. M.; Thomson, G.; Brennan, J. A.; Enevoldson, T. P.; Gilling-Smith, G.; Gould, D. A.; Harris, P. L.; McWilliams, R. G.; Nasser, H.-C.; White, R.; Prakash, K. G.; Serracino-Inglott, F.; Subramanian, G.; Symth, J. V.; Walker, M. G.; Clarke, M.; Davis, M.; Dixit, S. A.; Dorman, P.; Dyker, A.; Ford, G.; Golkar, A.; Jackson, R.; Jayakrishnan, V.; Lambert, D.; Lees, T.; Louw, S.; Macdonald, S.; Mendelow, A. D.; Rodgers, H.; Rose, J.; Stansby, G.; Wyatt, M.; Baker, T.; Baldwin, N.; Jones, L.; Mitchell, D.; Munro, E.; Thornton, M.; Baker, D.; Davis, N.; Hamilton, G.; McCabe, D.; Platts, A.; Tibballs, J.; Cleveland, T.; Dodd, D.; Lonsdale, R.; Nair, R.; Nassef, A.; Nawaz, S.; Venables, G.; Belli, A.; Cloud, G.; Halliday, A.; Markus, H.; McFarland, R.; Morgan, R.; Pereira, A.; Thompson, A.; Chataway, J.; Cheshire, N.; Gibbs, R.; Hammady, M.; Jenkins, M.; Malik, I.; Wolfe, J.; Adiseshiah, M.; Bishop, C.; Brew, S.; Brookes, J.; Jäger, R.; Kitchen, N.; Ashleigh, R.; Butterfield, S.; Gamble, G. E.; McCollum, C.; Nasim, A.; O'Neill, P.; Edwards, R. D.; Lees, K. R.; MacKay, A. J.; Moss, J.

    2010-01-01

    BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International

  18. Enterprise stenting for intracranial aneurysm treatment induces dynamic and reversible age-dependent stenosis in cerebral arteries.

    Science.gov (United States)

    Gao, Bulang; Safain, Mina G; Malek, Adel M

    2015-04-01

    Although intracranial stenting has been associated with in-stent stenosis, the vascular response of cerebral vessels to the deployment of the Enterprise vascular reconstruction device is poorly defined. To evaluate the change in parent vessel caliber that ensues after Enterprise stent placement. Seventy-seven patients with 88 aneurysms were treated using Enterprise stent-assisted coil embolization and underwent high-resolution three-dimensional rotational angiography followed by three-dimensional edge-detection filtering to remove windowing-dependence measurement artifact. Orthogonal diameters and cross-sectional areas (CSAs) were measured proximal and distal on either side of the leading stent edge (points A, B), trailing stent edge (points D, E), and at mid-stent (point C). Enterprise stent deployment caused an instant increase in the parent artery CSA by 8.98% at D, which was followed 4-6 months later by significant in-stent stenosis (15.78% at A, 27.24% at B, 10.68% at C, 32.12% at D, and 28.28% at E) in the stented artery. This time-dependent phenomenon showed resolution which was complete by 12-24 months after treatment. This target vessel stenosis showed significant age dependence with greater response in the young. No flow-limiting stenosis requiring treatment was observed in this series. Use of the Enterprise stent is associated with a significant dynamic and spontaneously resolvable age-dependent in-stent stenosis. Further study is warranted on the clinical impact, if any, of this occurrence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Intravascular ultrasound evaluation of a pseudolesion created by stent placement in the right artery.

    Science.gov (United States)

    Zientek, D M; Rodgers, G P

    1999-10-01

    The creation of a pseudolesion after guidewire placement in tortuous arterial segments is a well recognized phenomenon. Intravascular ultrasound has been useful in assessing deployment of intracoronary stents and equivocal angiographic findings. We present a case in which a pseudolesion was not observed until after placement of an intracoronary stent. Intravascular ultrasound demonstrated no dissection or significant lesion; however, there was focal calcification just distal to the stent providing a substrate for the distorted vessel architecture. The lesion resolved with removal of the guidewire.

  20. Surgical treatment of massive bleeding of a right aberrant subclavian artery after oesophageal stent removal

    Directory of Open Access Journals (Sweden)

    Michael Raum

    2018-06-01

    Full Text Available We report a case of a 9-year-old female who required surgical treatment and resuscitation after severe transoesophageal bleeding of a right aberrant subclavian artery (RASA. Bleeding of this RASA was caused by a mechanical irritation due to an oesophageal stent. The stent was placed weeks before to dilate the oesophagus after accidental ingestion of a caustic agent. Although conservative management of benign oesophageal stenosis in children is highly recommended, there are still some major complications to be considered. To avoid erosion of aberrant subclavian artery vascular rings and slings, as described in several case reports, these vessels should be excluded by computed tomography (CT or magnetic resonance imaging (MRI scans before placement of oesophageal stents. This case suggests that management of caustic ingestion in children is still a major challenge in paediatric surgical departments. Keywords: Paediatric surgery, Chemical Burn, Oesophageal stenosis, Oesophageal stenting, Vascular abnormalities, Right aberrant subclavian artery

  1. Silicon-carbide coated coronary stents have low platelet and leukocyte adhesion during platelet activation

    NARCIS (Netherlands)

    Monnink, SHJ; van Boven, AJ; Tigchelaar, [No Value; de Kam, PJ; Crijns, HJGM; van Oeveren, W

    Background: Stent thrombosis and restenosis are of great clinical significance. We constructed a closed loop in vitro heparinized whole human blood circulation model for testing hemocompatibility of coronary stents, This model allows evaluation of human blood activation by blood-stent interaction in

  2. Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

    International Nuclear Information System (INIS)

    Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.

    2009-01-01

    Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

  3. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Mæng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...... of the sirolimus-eluting Cypher® stent (SES) and the zotarolimus-eluting Endeavor® stent (ZES) on angiographic late lumen loss and intima hyperplasia in diabetic patients....

  4. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study) : an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Joerg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Bradbury, A.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molynewc, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Hendriks, J. M. H.; Hendriks, J. M.

    2010-01-01

    Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid

  5. Vertebral artery origin stent placement with distal protection: technical and clinical results.

    Science.gov (United States)

    Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N

    2006-05-01

    To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

  6. Stent placement with the monorail technique for treatment of mesenteric artery stenosis.

    Science.gov (United States)

    Schaefer, Philipp J; Schaefer, Fritz K W; Hinrichsen, Holger; Jahnke, Thomas; Charalambous, Nikolas; Heller, Martin; Mueller-Huelsbeck, Stefan

    2006-04-01

    To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.

  7. Angulated Stents-A Novel Stent Improvisation to Manage Difficult Post-tuberculosis Bronchial Stenosis.

    Science.gov (United States)

    Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong

    2017-10-18

    Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p < 0.05). Angulated stents are a feasible treatment option in patients with angulated PTBS by reducing complications and prolonging the stent-changing interval.

  8. Duplex criteria for determination of in-stent stenosis after angioplasty and stenting of the superficial femoral artery.

    Science.gov (United States)

    Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K

    2009-01-01

    Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis or=50% in-stent stenosis, a PSV >or=190 had 88% sensitivity, 95% specificity, a 98% positive predictive value (PPV), and a 72% negative predictive value (NPV); for Vr, a ratio of >1.50 had 93% sensitivity, 89% specificity, a 96% PPV, and a 81% NPV. To detect >or=80% in-stent stenosis, a PSV >or=275 had 97% sensitivity, 68% specificity, a 67% PPV, and a 97% NPV; a Vr ratio >or=3.50 had 74% sensitivity, 94% specificity, a 77% PPV, and a 88% NPV. Combining a PSV >or=275 and a Vr >or=3.50 to determine >or=80% in-stent stenosis had 74% sensitivity, 94% specificity, a 88% PPV, and a 85% NPV; odds ratio was 42.17 (95% confidence interval, 10.20-174.36, P or=80% in-stent stenosis. A significant drop in ABI (>0.15) correlated with a >62% in-stent stenosis, although the adjusted correlation coefficients was low (R(2) = 0.31, P = .02). PSV and Vr appear to have a significant role in predicting in-stent stenosis. To determine >or=80% stenosis, combining PSV >or=275 cm/s and Vr >or=3.50 is highly specific and predictive.

  9. Plastic strains during stent deployment have a critical influence on the rate of corrosion in absorbable magnesium stents.

    Science.gov (United States)

    Galvin, Emmet; Cummins, Christy; Yoshihara, Shoichiro; Mac Donald, Bryan J; Lally, Caitríona

    2017-08-01

    Magnesium stents are a promising candidate in the emerging field of absorbable metallic stents (AMSs). In this study, the mechanical and corrosion performance of dog-bone specimens and a specific stent design of a magnesium alloy, WE43, are assessed experimentally in terms of their corrosion behaviour and mechanical integrity. It is shown that plastic strains that are induced in the struts of the stent during stent deployment have a critical influence in directing subsequent corrosion behaviour within the material. In addition, the deployment and scaffolding characteristics of the magnesium stent are elucidated and contrasted with those of a commercial stainless steel stent. The magnesium stent is found to support higher levels of cyclic strain amplitude than the stainless steel stent, even prior to degradation, and this may play a role in reducing in-stent restenosis. This study provides new insights into the experimental performance of a current AMS design and material whilst demonstrating the critical influence of plastic strain on the corrosion performance and scaffolding ability of an AMS.

  10. Under X-ray guidance stent implantation through retrograde popliteal artery puncturing for the treatment of superficial femoral artery occlusion: the initial results in nine cases

    International Nuclear Information System (INIS)

    He Xu; Gu Jianping; Lou Wensheng; Chen Liang; Chen Guoping; Su Haobo; Song Jinhua; Wang Tao; Xu Ke

    2011-01-01

    Objective: To discuss the application of retrograde popliteal artery puncturing under X-ray guidance in the interventional therapy for superficial femoral artery occlusion. Methods: Retrograde popliteal artery puncturing under X-ray guidance was carried out in nine patients with long-segment occlusion of superficial femoral artery as antegrade recanalization via femoral artery approach had failed in them. After retrograde route was successfully established, the balloon dilation and subsequent stent placement for occluded vessel were performed. Results: The technical success was obtained in all patients. The occluded superficial femoral arteries were reopened and the symptoms of intermittent claudication disappeared. No serious complications such as injuries of adjacent nerves or vessels occurred. The ankle-brachial index (ABI) increased from preoperative (0.38±0.13) to postoperative (0.92±0.11) with the difference being statistically significant (P<0.01). A follow-up period lasting for 2-16 months was conducted. Eleven months after the treatment, intermittent claudication recurred in one case, and CT angiography showed that the distal part of the stent was narrowed. The symptoms were improved after percutaneous transcatheter angioplasty was performed again. Conclusion: Retrograde popliteal artery puncturing under X-ray guidance is an effective and safe technique for the treatment of superficial femoral artery long-segment occlusion with stent placement, especially for patients in whom antegrade recanalization via femoral artery approach fails. (authors)

  11. Treatment of internal carotid artery dissections with endovascular stent placement: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deok Hee; Hur, Seung Ho; Kim, Hyeon Gak; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)

    2000-03-01

    Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  12. Assessment of a Polyester-Covered Nitinol Stent in the Canine Aorta and Iliac Arteries

    International Nuclear Information System (INIS)

    Castaneda, Flavio; Ball-Kell, Susan M.; Young, Kate; Li Ruizong

    2000-01-01

    Purpose: To evaluate the patency and healing characteristics of a woven polyester fabric-covered stent in the canine model.Methods: Twenty-four self-expanding covered stents were placed in the infrarenal aorta and bilateral common iliac arteries of eight dogs and evaluated at 1 (n = 2), 3 (n = 2), and 6 (n = 4) months. Stent assessment was done using angiography prior to euthanasia, and light and scanning electron microscopy.Results: Angiographically, just prior to euthanasia, 8 of 8 aortic and 14 of 16 iliac endovascular covered stents were patent. Histologically, the stented regions showed complete endothelialization 6 months after graft implantation. A neointima had formed inside the stented vessel regions resulting in complete encasement of the fabric-covered stent by 3 months after graft implantation. Medial compression with smooth muscle cell atrophy was present in all stented regions. Explanted stent wires, examined by scanning electron microscopy, showed pitting but no cracks or breakage.Conclusion: The covered stent demonstrated predictable healing and is effective in preventing stenosis in vessels 10.0 mm or greater in diameter but does not completely preclude stenosis in vessels 6.0 mm or less in diameter

  13. Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Leoncio L. Kaw, Jr

    2006-10-01

    Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.

  14. Percutaneous endovascular therapy for symptomatic chronic total occlusion of the left subclavian artery.

    Science.gov (United States)

    Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan

    2018-03-16

    Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.

  15. [Measurements of blood velocities using duplex sonography in carotid artery stents: analysis of reliability in an in-vitro model and computational fluid dynamics (CFD)].

    Science.gov (United States)

    Schönwald, U G; Jorczyk, U; Kipfmüller, B

    2011-01-01

    Stents are commonly used for the treatment of occlusive artery diseases in carotid arteries. Today, there is a controversial discussion as to whether duplex sonography (DS) displays blood velocities (BV) that are too high in stented areas. The goal of this study was to evaluate the effect of stenting on DS with respect to BV in artificial carotid arteries. The results of computational fluid dynamics (CFD) were also used for the comparison. To analyze BV using DS, a phantom with a constant flow (70 cm/s) was created. Three different types of stents for carotid arteries were selected. The phantom fluid consisted of 67 % water and 33 % glycerol. All BV measurements were carried out on the last third of the stents. Furthermore, all test runs were simulated using CFD. All measurements were statistically analyzed. DS-derived BV values increased significantly after the placement of the Palmaz Genesis stent (77.6 ± 4.92 cm/sec, p = 0.03). A higher increase in BV values was registered when using the Precise RX stent (80.1 ± 2.01 cm/sec, p CFD simulations showed similar results. Stents have a significant impact on BV, but no effect on DS. The main factor of the blood flow acceleration is the material thickness of the stents. Therefore, different stents need different velocity criteria. Furthermore, the results of computational fluid dynamics prove that CFD can be used to simulate BV in stented silicone tubes. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Experimental study on effect of dexamethasone to the in-stent restenosis after vascular intervention

    International Nuclear Information System (INIS)

    Wang Jianbo; Yang Jianyong; Chen Wei; Zhuang Wenquan; Li Jiaping; Zhang Longjuan

    2007-01-01

    Objective: To evaluate the effect of dexamethasone to the cultured rat thoracic aortic smooth muscle cells (SMC) in vitro, and explore the role on it's prevention and cure for the in-stent restenosis after vascular intervention. Methods: The rat thoracic aortic SMC were harvested and cultured for six to ten passages. The cultured SMC were synchronized and then restimutated to enter the cell cycle, and treated with incremental concentrations of dexamethasone or without dexamethasone as control. The proliferative assay was performed with MTT method in the different time points after treatment. RT-PCR was performed to assay the level of proliferating cell nuclear antigen (PCNA) mRNA. Results: 1. Dexamethasone progressively inhibited rat aortic SMC proliferation in a concentration-dependent fashion. The A value was statistically significant for different concentrations (F=36.02, P -6 and 10 -5 mol/L (P=0.065) or between 10 -11 mol/L and control group (P 0.567). 2. RT-PCR suggested dexamethasone significantly decreased rat aortic SMC PCNA mRNA transcription in a concentration-dependent fashion. Statistical analysis indicated F=15.407 and P -9 or 10 -11 mol/L groups by post hoc analysis. Conclusions: Dexamethasone inhibits rat aortic SMC proliferation in a concentration- dependent fashion. The data suggest that effective action concentration is 10 -7 mol/L with persistent time up to 96 hours or more. Dexamethasone may play the inhibit role to SMC at lower concentration with prolonging action time. (authors)

  17. Randomized trial of Legflow® paclitaxel eluting balloon and stenting versus standard percutaneous transluminal angioplasty and stenting for the treatment of intermediate and long lesions of the superficial femoral artery (RAPID trial): Study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    A. Karimi; S.W. de Boer (Sanne W.); D.A.F. Van Den Heuvel; B. Fioole (Bram); D. Vroegindeweij (Dammis); J.M.M. Heyligers (Jan); P.N.M. Lohle (Paul N.M.); O.E. Elgersma (Otto E.); R.P.T. Nolthenius (Rudolf ); J.A. Vos (Jan Albert); J.-P.P.M. de Vries (Jean-Paul)

    2013-01-01

    textabstractBackground: Restenosis after percutaneous transluminal angioplasty (PTA) of the superficial femoral artery (SFA) may occur in 45% of patients at 2 years follow-up. Paclitaxel-coated balloons have been found to reduce neointimal hyperplasia, and thus reduce restenosis. Recently, the

  18. The effects of dextromethorphan on the outcome of percutaneous coronary intervention with bare-metal stent implantation

    Directory of Open Access Journals (Sweden)

    Wen-Cheng Liu

    2018-01-01

    Full Text Available Background: In the era of drug-eluting stents, although bare-metal stent (BMS remains an option for percutaneous coronary intervention (PCI, restenosis remains the Achilles' heel of BMS implantation. A recent study demonstrated several pleiotropic anti-inflammatory effects of dextromethorphan (DXM. This study aims to evaluate the effects of DXM on the outcome of PCI with BMS implantation.Methods: In this prospective, double-blind, randomized trial, we enrolled 55 patients who underwent PCI with BMS implantation from May 2006 to February 2009. The patients were divided into DXM (60 mg once daily and placebo groups. We compared mortality rates, myocardial infarction (MI, target lesion revascularization (TLR, restenosis, stent thrombosis, and plasma levels of high-sensitivity C-reactive protein (hs-CRP with repeated coronary angiography 6 months after the initial procedure.Results: During the 6-month follow-up period, no events of death, MI and stent thrombosis were reported in both groups. The TLR rate was 16.7% in patients receiving DXM compared to 24% receiving a placebo (P = 0.521. The restenosis rate was 30% in patients receiving DXM as compared to 40% receiving the placebo (P = 0.571. Although nonsignificant, the percentage of hs-CRP elevation was lower in the DXM group (20% compared to the placebo group 32%; P = 0.363.Conclusions: DXM is safe to use in patients who underwent PCI. Although DXM therapy following BMS implantation did not significantly reduce the TLR and restenosis rates, it implied a trend toward a lower TLR and restenosis and reduced inflammation in the DXM group compared to the placebo group. Nonetheless, further extensive studies are warranted to elucidate the anti-restenosis effects of DXM.

  19. Fluid-attenuated inversion recovery vascular hyperintensities in predicting cerebral hyperperfusion after intracranial arterial stenting

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Chih-Cheng; Chen, David Yen-Ting; Tseng, Ying-Chi; Lee, Kun-Yu; Chiang, Chen-Hua; Chen, Chi-Jen [Taipei Medical University, Department of Radiology, Shuang-Ho Hospital, New Taipei City (China); Taipei Medical University, School of Medicine, College of Medicine, Taipei (China); Yan, Feng-Xian [Taipei Medical University, Department of Radiology, Shuang-Ho Hospital, New Taipei City (China)

    2017-08-15

    No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS. We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated. The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P <.05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P <.001), overall nonstenting vascular (P <.001), and ipsilateral PCA (P <.05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings. FVHs could be a critical predictor of a significant increase in CBF after IAS. (orig.)

  20. Fluid-attenuated inversion recovery vascular hyperintensities in predicting cerebral hyperperfusion after intracranial arterial stenting

    International Nuclear Information System (INIS)

    Wan, Chih-Cheng; Chen, David Yen-Ting; Tseng, Ying-Chi; Lee, Kun-Yu; Chiang, Chen-Hua; Chen, Chi-Jen; Yan, Feng-Xian

    2017-01-01

    No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS. We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated. The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P <.05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P <.001), overall nonstenting vascular (P <.001), and ipsilateral PCA (P <.05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings. FVHs could be a critical predictor of a significant increase in CBF after IAS. (orig.)

  1. Direct Stenting in Patients with Acute Lower Limb Arterial Occlusions: Immediate and Long-Term Results

    International Nuclear Information System (INIS)

    Galanakis, Nikolaos; Kontopodis, Nikolaos; Peteinarakis, Ioannis; Kehagias, Elias; Ioannou, Christos V.; Tsetis, Dimitrios

    2017-01-01

    PurposeThe purpose of this study is to accentuate the efficacy of direct stenting (stent placement without predilatation of the lesion) in patients with acute lower limb arterial ischemia (ALLI).Materials and MethodsBetween January 2010 and September 2015, 16 patients (11 men and 5 women) underwent direct stenting of acute arterial occlusions. All patients had contraindication for surgical revascularization or catheter-directed thrombolysis. According to SVS/ISCVS Classification, six patients had IIa and ten patients IIb ALLI. The occlusions were located in CIA, EIA, SFA, or popliteal artery. Mean follow-up time with clinical examination and color Duplex ultrasonography was 37.6 months (range 1–72). We analyzed the technical and clinical outcomes of the procedures, as well the complications and patency rates.ResultsTechnical success was achieved in all patients (16/16) and there was significant clinical improvement in 15 patients. There was neither distal embolization nor procedure-related complications. During the 6 years of follow-up, four patients died due to non-procedure-related causes and there were two minor and one major amputations. The primary patency rates and the amputation-free survival rates were 93.7 and 87% at 1 year, 75.2 and 71.2% at 3 years, and 75.2 and 62.3%, respectively, at 6 years.ConclusionsDirect stenting may be a valuable alternative procedure for acute arterial occlusions in selected cases with high technical success and significant clinical improvement.Level of EvidenceLevel 4, Case Series.

  2. Direct Stenting in Patients with Acute Lower Limb Arterial Occlusions: Immediate and Long-Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Galanakis, Nikolaos [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece); Kontopodis, Nikolaos [University of Crete Medical School, Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital Heraklion (Greece); Peteinarakis, Ioannis; Kehagias, Elias [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece); Ioannou, Christos V. [University of Crete Medical School, Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital Heraklion (Greece); Tsetis, Dimitrios, E-mail: tsetis@med.uoc.gr [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece)

    2017-02-15

    PurposeThe purpose of this study is to accentuate the efficacy of direct stenting (stent placement without predilatation of the lesion) in patients with acute lower limb arterial ischemia (ALLI).Materials and MethodsBetween January 2010 and September 2015, 16 patients (11 men and 5 women) underwent direct stenting of acute arterial occlusions. All patients had contraindication for surgical revascularization or catheter-directed thrombolysis. According to SVS/ISCVS Classification, six patients had IIa and ten patients IIb ALLI. The occlusions were located in CIA, EIA, SFA, or popliteal artery. Mean follow-up time with clinical examination and color Duplex ultrasonography was 37.6 months (range 1–72). We analyzed the technical and clinical outcomes of the procedures, as well the complications and patency rates.ResultsTechnical success was achieved in all patients (16/16) and there was significant clinical improvement in 15 patients. There was neither distal embolization nor procedure-related complications. During the 6 years of follow-up, four patients died due to non-procedure-related causes and there were two minor and one major amputations. The primary patency rates and the amputation-free survival rates were 93.7 and 87% at 1 year, 75.2 and 71.2% at 3 years, and 75.2 and 62.3%, respectively, at 6 years.ConclusionsDirect stenting may be a valuable alternative procedure for acute arterial occlusions in selected cases with high technical success and significant clinical improvement.Level of EvidenceLevel 4, Case Series.

  3. Metallic stent implantation combined with intra-arterial chemotherapy for the treatment of malignant gastric and duodenal obstruction

    International Nuclear Information System (INIS)

    Cao Jun; Liu Hongqiang; He Yang; Xia Ning; Zhang Honglei; Qiao Delin

    2011-01-01

    Objective: To investigate the clinical effect of metallic stent implantation together with intra-arterial chemotherapy in treating malignant gastric and duodenal obstruction. Methods: A total of 32 patients with malignant gastric and duodenal obstruction were enrolled in this study. The obstructed sites were located at the gastric sinus and pylorus part (n=16), at the gastroduodenal anastomotic stoma (n=6) or at the descending part of duodenum (n=10). Under DSA guidance and with the additional help of endoscopy, a guide-wire was orally placed in the gastroduodenal obstructed site, which was followed by the implantation of the self-expanding metallic stent (Ni-Ti alloy). Postoperative intra-arterial chemotherapy via the tumor-feeding arteries was carried out in 16 patients (dual interventional therapy). The clinical results were analyzed. Results: Successful stent insertion was achieved in all 32 patients (100%). After stent implantation the obstructive symptoms were markedly relieved and the food intake was improved. No serious complications occurred. The median survival time for the 16 patients who had received dual interventional therapy was 9.3 months, while the median survival time for the other 16 patients who had received simple stenting therapy was 5.7 months. Conclusion: For the treatment of inoperable malignant gastroduodenal obstruction, the implantation of metallic self-expanding stents is a technically simple, clinically safe and effective palliative measure. Combined with postoperative intra-arterial chemotherapy, the metal stent implantation can control the tumor growth and elongate the survival time. (authors)

  4. Fibrosing Mediastinitis: Successful Stenting of the Pulmonary Artery

    Directory of Open Access Journals (Sweden)

    Rennae Thiessen

    2008-01-01

    Full Text Available Fibrosing mediastinitis is a rare benign condition, which can cause compression of the pulmonary or systemic vessels, tracheobronchial tree, coronary arteries or esophagus, leading to disabling clinical symptoms and even death. The case of a 26-year-old woman who presented with dyspnea is described. She was found to have 80% stenosis of the right pulmonary artery secondary to fibrosing mediastinitis. The stenosis was managed successfully with an endovascular Palmaz-Schatz stent, and the patient remains symptom-free 10 years later.

  5. New treatment of iliac artery disease: focus on the Absolute Pro® Vascular Self-Expanding Stent System

    Directory of Open Access Journals (Sweden)

    Gates L

    2013-09-01

    Full Text Available Lindsay Gates, Jeffrey Indes Vascular and Endovascular Surgery, Yale University School of Medicine, New Haven, CT, USA Abstract: Management of iliac artery disease has evolved over the years, from a surgical-only approach to a primarily endovascular-only approach as the first line treatment option. This has been continuously improved upon with the advent of new devices and applied technologies. Most recently in particular, the literature has shown good, reliable outcomes with the use of self-expandable stents in iliac artery atherosclerotic lesions. Nevertheless, no device is without its limitations, and the Absolute Pro® Vascular Self-Expanding Stent System was designed with the intent of overcoming some of the shortcomings of other available stents while maintaining acceptable postprocedural outcomes. Based on preliminary industry-acquired data, it has achieved these goals and appears to be an emergent competitor for the treatment of both focal and complex iliac artery lesions. Keywords: Absolute-Pro®, iliac stent, self-expanding stents, atherosclerotic disease

  6. A higher volume of fibrotic tissue on virtual histology prior to coronary stent implantation predisposes to more pronounced neointima proliferation.

    Science.gov (United States)

    Haine, Steven; Wouters, Kristien; Miljoen, Hielko; Vandendriessche, Tom; Claeys, Marc; Bosmans, Johan; Vrints, Christiaan

    2018-04-01

    Since neointima smooth muscle cells (SMC) mainly originate from the vessel wall, we investigated whether atherosclerotic plaque composition influences subsequent in-stent neointima proliferation and restenosis. We performed intravascular ultrasound (IVUS) with virtual histology in 98 patients prior to elective bare-metal stent (BMS) implantation in de novo coronary artery lesions. Virtual histology variables pre-percutaneous coronary intervention (PCI) were related to in-stent neointima proliferation six months after implantation assessed as late luminal loss of 0.88 mm (interquartile range (IQR) 0.37-1.23 mm) on angiography and as maximal percentage area stenosis of 42% (IQR 33-59%) and percentage volume intima hyperplasia of 27% (IQR 20-36%) on IVUS. A ridge-trace based multiple linear regression model was constructed to account for multicollinearity of the virtual histology variables and was corrected for implanted stent length (18 mm, IQR 15-23 mm), stent diameter (3.0 mm, IQR 2.75-3.5 mm) and lesion volume (146 mm³, IQR 80-201 mm³) prior to PCI. Fibrous tissue volume prior to PCI (49 mm³, IQR 30-77 mm³) was significantly and independently related to late luminal loss (p = .038), maximal percentage area stenosis (p = .041) and percentage volume intima hyperplasia (p = .004). Neither absolute nor relative amounts of fibrofatty, calcified or necrotic core tissue appeared related to any of the restenosis parameters. Subgroup analysis after exclusion of acute coronary syndrome (ACS) patients yielded similar results. Lesions with more voluminous fibrotic tissue pre-PCI show more pronounced in-stent neointima proliferation, even after correction for lesion plaque volume.

  7. Functional angiography of arteries near the knee joint: Consequences for stent implantation. Funktionsangiographie der kniegelenknahen Arterien: Konsequenzen fuer die Stentimplantation

    Energy Technology Data Exchange (ETDEWEB)

    Zocholl, G; Zapf, S; Schild, H; Thelen, M [Mainz Univ. (Germany, F.R.). Inst. fuer Klinische Strahlenkunde

    1990-12-01

    Angiographic studies of the arteries adjoining the knee in 25 patients show extensive kinking and stenoses of the popliteal artery and less frequently of the distal femoral artery during flexion of the knee joint. This is due to the loss of elasticity with increasing age forcing the vessel into a tortuous course during shortening of the pathway of the popliteal artery with knee flexion. Independent of the principle of the different stents available they probably will not increase the contractility of the stented vessel in the longitudinal axis. It is to expect that after implantation of stents into the original artery kinking will occur predominantly in the original segments of the vessel and at the transitions to the stented segments leading to intimal damage by shear forces thus propagating local progress of atherosclerosis. (orig.).

  8. Randomized trial of Legflow((R)) paclitaxel eluting balloon and stenting versus standard percutaneous transluminal angioplasty and stenting for the treatment of intermediate and long lesions of the superficial femoral artery (RAPID trial): study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    Karimi, A.; Boer, S.W. de; Heuvel, D.A. Van Den; Fioole, B.; Vroegindeweij, D.; Heyligers, J.M.M; Lohle, P.N.; Elgersma, O.; Nolthenius, R.P.T.; Vos, J.A.; Vries, J.P. de

    2013-01-01

    BACKGROUND: Restenosis after percutaneous transluminal angioplasty (PTA) of the superficial femoral artery (SFA) may occur in 45% of patients at 2 years follow-up. Paclitaxel-coated balloons have been found to reduce neointimal hyperplasia, and thus reduce restenosis. Recently, the Legflow((R))

  9. Subintimal Recanalization of Occluded Stents: The Substent Technique

    International Nuclear Information System (INIS)

    Diamantopoulos, Athanasios; Katsanos, Konstantinos; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris

    2013-01-01

    PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end points included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan–Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 ± 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 ± 90.78 mm. The mean occluded stented segment length was 90.21 ± 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year’s follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI with few

  10. An agent-based model of the response to angioplasty and bare-metal stent deployment in an atherosclerotic blood vessel.

    Directory of Open Access Journals (Sweden)

    Antonia E Curtin

    Full Text Available PURPOSE: While animal models are widely used to investigate the development of restenosis in blood vessels following an intervention, computational models offer another means for investigating this phenomenon. A computational model of the response of a treated vessel would allow investigators to assess the effects of altering certain vessel- and stent-related variables. The authors aimed to develop a novel computational model of restenosis development following an angioplasty and bare-metal stent implantation in an atherosclerotic vessel using agent-based modeling techniques. The presented model is intended to demonstrate the body's response to the intervention and to explore how different vessel geometries or stent arrangements may affect restenosis development. METHODS: The model was created on a two-dimensional grid space. It utilizes the post-procedural vessel lumen diameter and stent information as its input parameters. The simulation starting point of the model is an atherosclerotic vessel after an angioplasty and stent implantation procedure. The model subsequently generates the final lumen diameter, percent change in lumen cross-sectional area, time to lumen diameter stabilization, and local concentrations of inflammatory cytokines upon simulation completion. Simulation results were directly compared with the results from serial imaging studies and cytokine levels studies in atherosclerotic patients from the relevant literature. RESULTS: The final lumen diameter results were all within one standard deviation of the mean lumen diameters reported in the comparison studies. The overlapping-stent simulations yielded results that matched published trends. The cytokine levels remained within the range of physiological levels throughout the simulations. CONCLUSION: We developed a novel computational model that successfully simulated the development of restenosis in a blood vessel following an angioplasty and bare-metal stent deployment based on

  11. Spontaneous coronary artery dissection: complete angiographic resolution without stenting

    Directory of Open Access Journals (Sweden)

    Alexandre Abizaid

    2007-09-01

    Full Text Available A case of spontaneous coronary artery dissection in a 49-year-oldwoman is presented. She did not present the classical cardiovascular riskfactors. Etiology and treatment are discussed. She underwent primarypercutaneous coronary intervention of the left anterior descendingartery with no stenting and had complete angiographic resolution.

  12. [Coronary stents: 30 years of medical progress].

    Science.gov (United States)

    Silvain, Johanne; Cayla, Guillaume; Collet, Jean-Philippe; Fargeot, Catherine; Montalescot, Gilles

    2014-03-01

    The history of interventional cardiology has been marked by several technologic revolutions since the late 1970s. The first key step was the use of inflatable balloon angioplasty as an alternative to CABG surgery for coronary revascularization, followed by intracoronary delivery of bare metal stent (BMS) and drug eluting stents (DES) to drastically reduce intracoronary restenosis observed with BMS. Improved stents platforms and polymers (absorbable or biocompatible) led to a dramatic reduction in the rate of late stent thrombosis. Self-expanding stents are now available to improve stent a position especially in acute myocardial infarction. The emergence of new fully bioabsorbable stents that can be combined with antiproliferative drugs is the ongoing revolution. A new generation of stents is continuously improving and likely to become the ideal stent for coronary revascularization in the near future. © 2014 médecine/sciences – Inserm.

  13. Incidence of New Ischaemic Brain Lesions After Carotid Artery Stenting with the Micromesh Roadsaver Carotid Artery Stent: A Prospective Single-Centre Study

    Energy Technology Data Exchange (ETDEWEB)

    Ruffino, Maria Antonella, E-mail: mruffino@cittadellasalute.to.it [Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Vascular Radiology Unit, Department of Diagnostic Imaging and Radiotherapy (Italy); Faletti, Riccardo [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Radiology Unit, Department of Surgical Sciences (Italy); Bergamasco, Laura [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Department of Surgical Sciences (Italy); Fonio, Paolo [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Radiology Unit, Department of Surgical Sciences (Italy); Righi, Dorico [Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Vascular Radiology Unit, Department of Diagnostic Imaging and Radiotherapy (Italy)

    2016-11-15

    AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm{sup 3} (interquartile range 0.065–0.146 cm{sup 3}). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.

  14. Incidence of New Ischaemic Brain Lesions After Carotid Artery Stenting with the Micromesh Roadsaver Carotid Artery Stent: A Prospective Single-Centre Study

    International Nuclear Information System (INIS)

    Ruffino, Maria Antonella; Faletti, Riccardo; Bergamasco, Laura; Fonio, Paolo; Righi, Dorico

    2016-01-01

    AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm"3 (interquartile range 0.065–0.146 cm"3). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.

  15. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    Science.gov (United States)

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  16. Bioabsorbable Stent Quo Vadis: A Case for Nano-Theranostics

    Science.gov (United States)

    Gundogan, Buket; Tan, Aaron; Farhatnia, Yasmin; Alavijeh, Mohammad S.; Cui, Zhanfeng; Seifalian, Alexander M.

    2014-01-01

    Percutaneous coronary intervention (PCI) is one of the most commonly performed invasive medical procedures in medicine today. Since the first coronary balloon angioplasty in 1977, interventional cardiology has seen a wide array of developments in PCI. Bare metal stents (BMS) were soon superseded by the revolutionary drug-eluting stents (DES), which aimed to address the issue of restenosis found with BMS. However, evidence began to mount against DES, with late-stent thrombosis (ST) rates being higher than that of BMS. The bioabsorbable stent may be a promising alternative, providing vessel patency and support for the necessary time required and thereafter degrade into safe non-toxic compounds which are reabsorbed by the body. This temporary presence provides no triggers for ST, which is brought about by non-endothelialized stent struts and drug polymers remaining in vivo for extended periods of time. Likewise, nano-theranostics incorporated into a bioabsorbable stent of the future may provide an incredibly valuable single platform offering both therapeutic and diagnostic capabilities. Such a stent may allow delivery of therapeutic particles to specific sites thus keeping potential toxicity to a minimum, improved ease of tracking delivery in vivo by embedding imaging agents, controlled rate of therapy release and protection of the implanted therapy. Indeed, nanocarriers may allow an increased therapeutic index as well as offer novel post-stent implantation imaging and diagnostic methods for atherosclerosis, restenosis and thrombosis. It is envisioned that a nano-theranostic stent may well form the cornerstone of future stent designs in clinical practice. PMID:24672583

  17. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito [Kainan Hospital Aichi Prefectural Welfare Federation of Agricultural Cooperatives, Department of Neurosurgery, Aichi (Japan); Miyachi, Shigeru; Hattori, Kenichi [Nagoya University Graduate School of Medicine, Department of Neurosurgery, Nagoya (Japan)

    2006-11-15

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  18. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    International Nuclear Information System (INIS)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito; Miyachi, Shigeru; Hattori, Kenichi

    2006-01-01

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  19. A clinical study on perforator stroke resulting from Wingspan stent angioplasty for symptomatic intracranial artery stenosis

    International Nuclear Information System (INIS)

    Wang Ziliang; Xu Haowen; Li Tianxiao; Zhu Liangfu; Li Zhaoshuo; Xue Jiangyu; Bai Weixing; Li Li; Guan Sheng

    2011-01-01

    Objective: To evaluate the incidence, potential hazards and effective countermeasure for perforator stroke (PS) resulting from stent angioplasty of symptomatic intracranial artery stenosis. Methods: Peri-operation PS complications of 258 patients receiving Gateway balloon-Wingspan stenting for severe symptomatic intracranial stenosis were analyzed. The incidence, clinical course, and prognosis of PS resulting from stenting were recorded. Special attention was given to the anatomical features, clinical manifestation and video materials of patients with PS. χ 2 test was used for statistics. Results: Two hundred and fifty-five patients received stent angioplasty successfully and 7 patients had PS (incidence rate 2.7%). The patients with basilar artery stenosis had a higher incidence of PS resulting from intracranial stenting (6.1%, 4/66) than patients with middle cerebral artery stenosis (2.5%, 3/118) (χ 2 =2.320, P= 0.025). The potential hazards for PS included preoperative perforator stroke adjacent to the stenotic segment and prominent dissection during operation. Six patients presented symptoms after awake from general anaesthesia and one had symptoms 3 hours after stenting. One deteriorated gradually and the others reached the maximum deficit almost at once. At the follow-up of 3 months, 3 patients were disabled and scored one, two, two by mRS respectively. Conclusion: The incidence of PS resulting from intracranial stenting was low and the prognosis was not disastrous. Stenosis at basilar artery and preoperative perforator stroke adjacent to the stenotic segment were potential risk factors for PS complication. Proper maneuver of angioplasty may decrease the incidence of PS and improve the prognosis. (authors)

  20. Effect of white-matter lesions on the risk of periprocedural stroke after carotid artery stenting versus endarterectomy in the International Carotid Stenting Study (ICSS): a prespecified analysis of data from a randomised trial

    NARCIS (Netherlands)

    Ederle, J.; Davagnanam, I.; Worp, H.B. van der; Venables, G.S.; Lyrer, P.A.; Featherstone, R.L.; Brown, M.M.; Jager, H.R.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,

    2013-01-01

    BACKGROUND: Findings from randomised trials have shown a higher early risk of stroke after carotid artery stenting than after carotid endarterectomy. We assessed whether white-matter lesions affect the perioperative risk of stroke in patients treated with carotid artery stenting versus carotid

  1. ANGIOPLASTIA PERCUTÁNEA CON STENT EN EL TRONCO PRINCIPAL DE LA ARTERIA CORONARIA IZQUIERDA / Percutaneous angioplasty with stent in the left main coronary artery

    Directory of Open Access Journals (Sweden)

    Javier Almeida Gómez

    2012-10-01

    is coronary artery bypass surgery. In several multicenter studies, the possibility of treating coronary artery disease by percutaneous coronary intervention with implantation of endoluminal prosthesis or stent is suggested. The objective of this research was to characterize percutaneous angioplasty with stent in the left main coronary artery. Method: An observational, descriptive and transversal study was carried out in 21 patients with percutaneous angioplasty with stent in the left main coronary artery, performed in the laboratory of Hemodynamics and Interventional Cardiology of Hermanos Ameijeiras Hospital, between January 2010 and July 2011. Results: There was no significant difference in sex. The age group 50-64 years (47.6% and white skin color (76.19% were predominant. The most commonly found cardiovascular risk factor was hypertension (85.71%, followed by dyslipidemia (47.61%. Effort angina was the most observed diagnosis with 14 cases (66.66%. The lesion in the body of the trunk (12 patients, 57.1% was the most prevalent, followed by ostial lesion (8 cases. Drug-eluting (61.9% was the most used type of stent and only 4 patients had surgically protected trunks. Conclusions: Most cases were elective, with a predominance of unprotected trunks. Hypertension was the coronary risk factor most commonly found. A significant association between diabetes mellitus and ostial location of the lesion was found.

  2. Edge Stenosis After Covered Stenting for Long Superficial Femoral Artery Occlusive Disease: Risk Factor Analysis and Prevention With Drug-Coated Balloon Angioplasty.

    Science.gov (United States)

    Lin, Ting-Chao; Huang, Chun-Yang; Chen, Po-Lin; Lee, Chiu-Yang; Shih, Chun-Che; Chen, I-Ming

    2018-06-01

    To report a retrospective analysis of risk factors for edge restenosis after Viabahn stent-graft treatment of superficial femoral artery (SFA) occlusive disease and determine any protective effect of drug-coated balloons (DCBs) used at the time of stent-graft implantation. Between October 2011 and July 2016, 110 patients (mean age 73.3±7.6 years; 78 men) were treated with the Viabahn stent-graft for long SFA occlusions. Thirty-eight (34.5%) patients had DCB reinforcement at the distal edge of the stent-graft. For analysis, the population was divided into groups of no edge stenosis patients (n=88; mean lesion length 22.4±4.2 cm) and edge stenosis patients (n=22; mean lesion length 23.5±5.7 cm). The clinical outcomes, ankle-brachial indices, computed tomography angiography findings, and patency were compared at a minimum of 12 months. Logistic regression analysis was employed to determine risk factors for edge stenosis; the results are presented as the odds ratio (OR) and 95% confidence interval. No differences in clinical or procedural characteristics were identified except the higher incidence of diabetes (p=0.008) and greater need for retrograde access (p=0.033) in the edge stenosis group. DCB reinforcement reduced the incidence of edge stenosis (p=0.021) and target lesion revascularization (TLR; p=0.010) and resulted in a significantly higher 1-year primary patency rate (92.1% vs 76.4%, p=0.042). However, multivariate analysis revealed only poor distal runoff (OR 0.31, 95% CI 0.11 to 0.83, p=0.020) as a predictor of edge stenosis. The risk of edge stenosis after Viabahn implantation was higher in patients with poor distal runoff. DCB reinforcement over the distal edge reduced edge stenosis, decreased 1-year TLR, and improved 1-year primary patency.

  3. Increased Plasma Cathepsin S at the Time of Percutaneous Transluminal Angioplasty is Associated with 6-Months’ Restenosis of the Femoropopliteal Artery

    Directory of Open Access Journals (Sweden)

    Mijovski Mojca Bozic

    2018-01-01

    Full Text Available Background: We tested the hypothesis that increased levels of cathepsin S and decreased levels of cystatin C in plasma at the time of percutaneous transluminal angioplasty (PTA are associated with the occurrence of 6-months’ restenosis of the femoropopliteal artery (FPA. Methods: 20 patients with restenosis and 24 matched patients with patent FPA after a 6-months follow-up were in - cluded in this study. They all exhibited disabling claudication or critical limb ischemia and had undergone technically successful PTA. They were all receiving statins and ACE in hi - bitors (or angiotensin II receptor antagonist before the PTA and the therapy did not change throughout the observational period. Plasma concentrations of C-reactive protein were < 10 mg/L and of creatinine within the reference range at the time of the PTA. Plasma concentration and activity of cathepsin S, together with its potent inhibitor cystatin C, were measured the day before and the day after the PTA. Results: The increased plasma concentration and activity of cathepsin S at the time of PTA was associated with the occurrence of 6-months’ restenosis of FPA, independently of established risk factors (lesion complexity, infrapopliteal run-off vessels, type of PTA, age, gender, smoking, diabetes, lipids and of cystatin C. Plasma cystatin C concentration was not associated with restenosis and did not correlate with cathepsin S activity and concentration in the plasma. Conclusion: Increased level of plasma cathepsin S at the time of PTA is associated with 6-months’ restenosis of PTA, independently of established risk factors.

  4. Treatment of carotid siphon aneurysms by use of the Willis stent graft: an angiographic and histopathological study

    International Nuclear Information System (INIS)

    Zhu, Yue-Qi; Li, Ming-Hua; Xie, Jian; Tan, Hua-Qiao; Wang, Jian-Bo; Cheng, Ying-Sheng

    2010-01-01

    We designed a carotid siphon (CS) aneurysm model in dogs to test a new stent graft (the Willis covered stent) and compared tissue reaction over 12-month follow-up versus a comparison group with stents implanted in straight vessels. Twenty-four saccular sidewall aneurysms (group A) and 12 CS aneurysms (group B) were created surgically. A Willis stent graft was implanted in each aneurysm. Angiography was performed immediately and at 1-, 3-, 6- and 12-month post-implantation to investigate aneurysm isolation, endoleak, stent angulation, parent artery (PA) patency and restenosis. Light and scanning electron microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress. Immediate angiography demonstrated mild endoleak in two aneurysms and three stent angulations in group B. Follow-up at 12 months revealed resolved endoleaks, occlusion in one PA and mild stenosis in three in group B. In group A, occlusion occurred in one PA and mild stenosis in two. Light microscopy revealed new intima, and all aneurysm sacs were filled with thrombi. In group B, endothelial progress was complete at 12 months, and closely correlated with haemodynamic changes. Application of a Willis stent graft is a feasible method of treating CS aneurysms, and it exhibits a prolonged endothelial progress compared with that in straight vessels. (orig.)

  5. Medical therapy v. PCI in stable coronary artery disease: a cost-effectiveness analysis.

    Science.gov (United States)

    Wijeysundera, Harindra C; Tomlinson, George; Ko, Dennis T; Dzavik, Vladimir; Krahn, Murray D

    2013-10-01

    Percutaneous coronary intervention (PCI) with either drug-eluting stents (DES) or bare metal stents (BMS) reduces angina and repeat procedures compared with optimal medical therapy alone. It remains unclear if these benefits are sufficient to offset their increased costs and small increase in adverse events. Cost utility analysis of initial medical therapy v. PCI with either BMS or DES. . Markov cohort decision model. Data Sources. Propensity-matched observational data from Ontario, Canada, for baseline event rates. Effectiveness and utility data obtained from the published literature, with costs from the Ontario Case Costing Initiative. Patients with stable coronary artery disease, confirmed after angiography, stratified by risk of restenosis based on diabetic status, lesion size, and lesion length. Time Horizon. Lifetime. Perspective. Ontario Ministry of Health and Long Term Care. Interventions. Optimal medical therapy, PCI with BMS or DES. Lifetime costs, quality-adjusted life years (QALYs), and the incremental cost-effectiveness ratio (ICER). of Base Case Analysis. In the overall population, medical therapy had the lowest lifetime costs at $22,952 v. $25,081 and $25,536 for BMS and DES, respectively. Medical therapy had a quality-adjusted life expectancy of 10.1 v. 10.26 QALYs for BMS, producing an ICER of $13,271/QALY. The DES strategy had a quality-adjusted life expectancy of only 10.20 QALYs and was dominated by the BMS strategy. This ranking was consistent in all groups stratified by restenosis risk, except diabetic patients with long lesions in small arteries, in whom DES was cost-effective compared with medical therapy (ICER of $18,826/QALY). Limitations. There is the possibility of residual unobserved confounding. In patients with stable coronary artery disease, an initial BMS strategy is cost-effective.

  6. Research progress of biodegradable stent in the application for benign luminal stenosis

    International Nuclear Information System (INIS)

    Zhu Yueqi; Cheng Yingsheng; Li Minghua

    2008-01-01

    Stent implantation plays an significant role in the interventional therapy, mainly with permanent stent, possessing many disadvantages such as restenosis and inflammatory hyperplasia and can thus hardly be used in children and nonmalignant stenosis. Biodegradable stent has theoretical capability to solve these problems and acquires a bright future. Nowadays, with the development of material industry and manufacture craft, biodegradable stent technique has turned up to be mature in last decades. Through the strict animal experiments and prophase of clinic application, satisfactory result has been acquired. We believe that bioabsorbable stent will be widely used in many benign diseases which would be a good supplement for permanent stent in the near future. (authors)

  7. Metallic stent implantation in patients with iliac artery occlusion: long-term patency rate and factors related to recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Seok Kyun; Kim, Jae Kyu; Yoon, Woong; Kim, Jeong; Park, Jin Gyoon; Kang, Heoung Keun; Choi, Soo JinNa [Chonnam National University Hospital School of Medicine, Gwangju (Korea, Republic of)

    2003-09-01

    To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence. Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of follow-up varied from 1 day to 73 months (mean, 23.8 months). Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence (p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the fontaine stage were not statistically significant indicators of recurrence. The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery.

  8. Metallic stent implantation in patients with iliac artery occlusion: long-term patency rate and factors related to recurrence

    International Nuclear Information System (INIS)

    Chung, Seok Kyun; Kim, Jae Kyu; Yoon, Woong; Kim, Jeong; Park, Jin Gyoon; Kang, Heoung Keun; Choi, Soo JinNa

    2003-01-01

    To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence. Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of follow-up varied from 1 day to 73 months (mean, 23.8 months). Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence (p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the fontaine stage were not statistically significant indicators of recurrence. The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery

  9. Triple antithrombotic therapy in patients with atrial fibrillation undergoing coronary artery stenting: hovering among bleeding risk, thromboembolic events, and stent thrombosis

    Directory of Open Access Journals (Sweden)

    Menozzi Mila

    2012-10-01

    Full Text Available Abstract Dual antiplatelet treatment with aspirin and clopidogrel is the antithrombotic treatment recommended after an acute coronary syndrome and/or coronary artery stenting. The evidence for optimal antiplatelet therapy for patients, in whom long-term treatment oral anticoagulation is mandatory, is however scarce. To evaluate the safety and efficacy of the various antithrombotic strategies adopted in this population, we reviewed the available evidence on the management of patients receiving oral anticoagulation, such as a vitamin-k-antagonists, referred for coronary artery stenting. Atrial fibrillation is the most frequent indication for oral anticoagulation. The need of starting antiplatelet therapy in this clinical scenario raises concerns about the combination to choose: triple therapy with warfarin, aspirin, and a thienopyridine being the most frequent and advised. The safety of this regimen appeared suboptimal because of an increased risk in hemorrhagic complications. On the other hand, the combination of oral anticoagulation and an antiplatelet agent is suboptimal in preventing thromboembolic events and stent thrombosis; dual antiplatelet therapy may be considered only when a high hemorrhagic risk and low thromboembolic risk are perceived. Indeed, the need for prolonged multiple-drug antithrombotic therapy increases the bleeding risks when drug eluting stents are used. Since current evidence derives mainly from small, single-center and retrospective studies, large-scale prospective multicenter studies are urgently needed.

  10. A Comparison of Stent Implant versus Medical Treatment for Severe Symptomatic Intracranial Stenosis: A Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Rezao Mohammadian

    2012-11-01

    Full Text Available Background: Atherosclerotic stenosis of the major intracranial arteries is the most common cause of ischemic stroke. There are limited treatments for severe intracranial stenosis, and stent placement versus medical treatment remains controversial. The aim of this study was to compare functional outcomes of these two modalities in patients with severe symptomatic intracranial stenosis. Methods: At a single center, between 2008 and 2011, patients with angiographically demonstrated severe (70–90% symptomatic intracranial atherosclerosis were divided into two groups: group A, which received only medical treatment, and group B, which underwent endovascular stent implant treatment. The severity and location of the stenosis was determined by digital subtraction angiography and the Warfarin-Aspirin Symptomatic Intracranial Disease (WASID trial criteria in all patients. The exclusion criteria were: specific causes other than atherosclerosis, such as artery dissection, fibromuscular dysplasia, vasculitis, radiation and intracranial hemorrhage, focal neurological deficit that did not correlate to internal carotid artery or middle cerebral artery stenosis. All procedures were done under light anesthesia. Technical success was defined as the reduction of stenosis to Results: Overall, 63 patients (29 in group A and 34 in group B were evaluated and followed for a mean period of 15.22 months (range 6–25. The technical success rate was 97% in a total of 34 stents in 34 patients. There was no difference between the early (within 30 days adverse event rates of the two groups. The median follow-up duration for the stent implant patients was 15 months (range 6–25, and for the medically treated cohort it was 14 months (range 8–25. The re-stenosis rate was 5.8% and the total number of late (>30 days adverse events, including stroke, myocardial infarction and death, was 1 (2.9% and 6 (20.7% in the stent implant and medical groups, respectively (p = 0.042. The

  11. Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

    International Nuclear Information System (INIS)

    Struffert, Tobias; Ott, Sabine; Adamek, Edyta; Schwarz, Marc; Engelhorn, Tobias; Kloska, Stephan; Doerfler, Arnd; Deuerling-Zheng, Yu

    2011-01-01

    Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents. (orig.)

  12. High-definition computed tomography for coronary artery stents imaging: Initial evaluation of the optimal reconstruction algorithm.

    Science.gov (United States)

    Cui, Xiaoming; Li, Tao; Li, Xin; Zhou, Weihua

    2015-05-01

    The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0±8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  14. Peri-procedural complications and associated risk factors in wingspan stent-assistant angioplasty of intracranial artery stenosis

    International Nuclear Information System (INIS)

    Li Zhaoshuo; Li Tianxiao; Wang Ziliang; Bai Weixing; Xue Jiangyu; Zhu Liangfu; Li Li

    2013-01-01

    Objective: To retrospectively evaluate the cerebrovascular complications from stenting for symptomatic intracranial stenosis and to detect the factors associated with complications. Methods: Medical records of Wingspan stenting were reviewed for 306 cases with symptomatic intracranial stenosis from July 2007 to February 2012, including transient ischemic attack, ischemic stroke, death and intracranial hemorrhage as clinical in-hospital complications. The location of lesions included middle cerebral artery level M1 (114 lesions), intracranial portion of the internal carotid artery (50 lesions), vertebral artery 4 (75 lesions), venebro-basilar artery (14 lesions), basilar artery (76 lesions). Complications were evaluated and analyzed to find out whether they were associated with patient-or stenosis-related risk factors using χ"2 test. Results: The technical success rate was 99% (303/306). Cerebrovascular complications rate was 6.9% (21/303), with 1.6% (14/303) of disabling stroke events and 0.7% (2/303) of deaths. Hemorrhagic events were consisted of procedure-related events (3 cases), hyperperfusion (3 cases), ischemic events of perforator stroke (8 cases), transient ischemic attack (3 cases), embolization (2 cases), thrombosis in stent (2 cases). Hemorrhagic events were associated with significantly higher morbidity and mortality rates (χ"2 = 2.908, P < 0.05) and occurred more frequently after treatment of middle cerebral artery stenosis than other lesions (χ"2 = 1.168, P < 0.05). Perforating branches were detected to be affected mainly in the basilar artery than other locations (χ"2 = 4.263, P < 0.05). Conclusion: The complication rates in the study are preliminary consistent with the previously published data. Hemorrhagic events are prone to occur in the treatment of middle cerebral artery stenosis, while perforating branches are affected mainly in the basilar artery. (authors)

  15. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  16. Factors associated with coronary artery disease progression assessed by serial coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Camargo, Gabriel Cordeiro; Gottlieb, Ilan; Rothstein, Tamara; Derenne, Maria Eduarda; Sabioni, Leticia; Lima, Ronaldo de Souza Leão; Lima, João A. C.

    2017-01-01

    Background: Coronary computed tomography angiography (CCTA) allows for noninvasive coronary artery disease (CAD) phenotyping. Factors related to CAD progression are epidemiologically valuable. Objective: To identify factors associated with CAD progression in patients undergoing sequential CCTA testing. Methods: We retrospectively analyzed 384 consecutive patients who had at least two CCTA studies between December 2005 and March 2013. Due to limitations in the quantification of CAD progression, we excluded patients who had undergone surgical revascularization previously or percutaneous coronary intervention (PCI) between studies. CAD progression was defined as any increase in the adapted segment stenosis score (calculated using the number of diseased segments and stenosis severity) in all coronary segments without stent (in-stent restenosis was excluded from the analysis). Stepwise logistic regression was used to assess variables associated with CAD progression. Results: From a final population of 234 patients, a total of 117 (50%) had CAD progression. In a model accounting for major CAD risk factors and other baseline characteristics, only age (odds ratio [OR] 1.04, 95% confidence interval [95%CI] 1.01–1.07), interstudy interval (OR 1.03, 95%CI 1.01–1.04), and past PCI (OR 3.66, 95%CI 1.77–7.55) showed an independent relationship with CAD progression. Conclusions: A history of PCI with stent placement was independently associated with a 3.7-fold increase in the odds of CAD progression, excluding in-stent restenosis. Age and interstudy interval were also independent predictors of progression. (author)

  17. Factors associated with coronary artery disease progression assessed by serial coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Gabriel Cordeiro; Gottlieb, Ilan, E-mail: ilangottlieb@gmail.com [Casa de Saúde São José, Rio de Janeiro, RJ (Brazil); Rothstein, Tamara; Derenne, Maria Eduarda; Sabioni, Leticia; Lima, Ronaldo de Souza Leão [Centro de Diagnóstico por Imagem CDPI, Rio de Janeiro, RJ (Brazil); Lima, João A. C. [Johns Hopkins University, Baltimore (United States)

    2017-05-15

    Background: Coronary computed tomography angiography (CCTA) allows for noninvasive coronary artery disease (CAD) phenotyping. Factors related to CAD progression are epidemiologically valuable. Objective: To identify factors associated with CAD progression in patients undergoing sequential CCTA testing. Methods: We retrospectively analyzed 384 consecutive patients who had at least two CCTA studies between December 2005 and March 2013. Due to limitations in the quantification of CAD progression, we excluded patients who had undergone surgical revascularization previously or percutaneous coronary intervention (PCI) between studies. CAD progression was defined as any increase in the adapted segment stenosis score (calculated using the number of diseased segments and stenosis severity) in all coronary segments without stent (in-stent restenosis was excluded from the analysis). Stepwise logistic regression was used to assess variables associated with CAD progression. Results: From a final population of 234 patients, a total of 117 (50%) had CAD progression. In a model accounting for major CAD risk factors and other baseline characteristics, only age (odds ratio [OR] 1.04, 95% confidence interval [95%CI] 1.01–1.07), interstudy interval (OR 1.03, 95%CI 1.01–1.04), and past PCI (OR 3.66, 95%CI 1.77–7.55) showed an independent relationship with CAD progression. Conclusions: A history of PCI with stent placement was independently associated with a 3.7-fold increase in the odds of CAD progression, excluding in-stent restenosis. Age and interstudy interval were also independent predictors of progression. (author)

  18. Direct stent puncture technique for intraluminal stent recanalization in the superficial femoral and popliteal arteries in-stent occlusion: Outcomes from a prospective clinical analysis of diabetics with critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Manzi, Marco

    2013-07-15

    Purpose: To evaluate the efficacy and safety of “Direct Stent Puncture” technique for intraluminal stent recanalization in the femoro-popliteal segments. Methods and Materials: A cohort of diabetics who had symptomatic in-stent occlusion of the superficial femoral or popliteal arteries underwent endovascular recanalization. After antegrade failure, direct stent puncture technique was performed. The primary end-point was to efficacy assessment, intended as technical success and clinical improvement. The secondary end-point was safety assessment, intended as free of complication rate. Results: Fifty-four patients (37 men; 73.6 ± 8.5 years) underwent direct stent puncture technique, after several unsuccessful antegrade attempts to cross the occluded stent. Technical success for intraluminal stent recanalization was achieved in 53/54 (98.2%) of cases and failed in 1/54 (1.8%). Clinical improvement was obtained in 51/54 (94.4%) of cases, with regression of the clinical symptoms and improvement of the TcPO{sub 2}, from 3 ± 18 mmHg to 43 ± 11 mmHg after 15 days (p < 0.001). Free of complications rate was 92.5%. In 2/54 (3.7%) of cases distal embolization occurred, in 1/54 (1.9%) case a sudden vessel thrombosis was diagnosed after 12 hours and in 1/54 (1.9%) case hematoma at the stent puncture site was observed. Conclusions: Direct Stent Puncture technique is an efficacy and safety option for intraluminal stent recanalization in the femoro-popliteal segment in-stent occlusion.

  19. Endovascular repair of renal artery aneurysm with the multilayer stent – a short report

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2012-10-01

    in the main left renal artery involving all three major branches of the renal artery. Via a percutaneous femoral approach a multilayer stent was deployed without complications. Blood flow inside the sac was immediately and significantly reduced. All the renal branches remained patent. Conclusion: New multilayer fluid modulating stent concept appears to be a very useful and attractive alternative to surgery or other endovascular techniques for those RAA involving or very close to major branch vessels, especially in patients with very high risk of loosing the only viable kidney, as in our case.

  20. Analysis of trends and prospects regarding stents for human blood vessels.

    Science.gov (United States)

    Lee, Jeong Hee; Kim, Eung Do; Jun, Eun Jung; Yoo, Hyoung Sun; Lee, Joon Woo

    2018-01-01

    The purpose of this paper is to provide technology trends and information regarding market and prospects in stents used for human blood vessels in Korea and the world.A stent is a medical device in the form of a cylindrical metal net used to normalize flow when blood or other bodily fluids such as biliary fluids are obstructed in blood vessels, gastrointestinal tracts, etc. by inserting the stent into a narrowed or clogged area. Stents are classified into vascular and non-vascular stents. The coronary artery stent is avascular stent that is used for coronary atherosclerosis.The demand is increasing for stents to treat diseases such as those affecting the heart and blood vessels of elderly and middle-aged patients. Due to the current shift in the demographic structure caused by an aging society, the prospect for stents seems to be very bright.The use of a stent designed to prevent acute vascular occlusion and restenosis, which is a side effect of conventional balloon angioplasty, has rapidly become popular because it can prevent acute complications and improve clinical outcomes. Since the initial release of this stent, there have been significant developments in its design, the most notable of which has been the introduction of drug-eluting stents (DES). Bioresorbable scaffolds (BRS) have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by a persistent metallic foreign body. Data for this research were gathered from primary and secondary sources as well as the databases of the Korea Institute of Science Technology Information (KISTI) located in Seoul, Korea like KISTI Market Report. The sources used for primary research included the databases available from the Korea Institute of Science Technology Information, past industry research services/studies, economic and demographic data, and trade and industry journals. Secondary research was used