WorldWideScience

Sample records for arterio-venous oxygen content

  1. The effect of in-plane arterial curvature on blood flow and oxygen transport in arterio-venous fistulae

    Science.gov (United States)

    Iori, F.; Grechy, L.; Corbett, R. W.; Gedroyc, W.; Duncan, N.; Caro, C. G.; Vincent, P. E.

    2015-03-01

    Arterio-Venous Fistulae (AVF) are the preferred method of vascular access for patients with end stage renal disease who need hemodialysis. In this study, simulations of blood flow and oxygen transport were undertaken in various idealized AVF configurations. The objective of the study was to understand how arterial curvature affects blood flow and oxygen transport patterns within AVF, with a focus on how curvature alters metrics known to correlate with vascular pathology such as Intimal Hyperplasia (IH). If one subscribes to the hypothesis that unsteady flow causes IH within AVF, then the results suggest that in order to avoid IH, AVF should be formed via a vein graft onto the outer-curvature of a curved artery. However, if one subscribes to the hypothesis that low wall shear stress and/or low lumen-to-wall oxygen flux (leading to wall hypoxia) cause IH within AVF, then the results suggest that in order to avoid IH, AVF should be formed via a vein graft onto a straight artery, or the inner-curvature of a curved artery. We note that the recommendations are incompatible—highlighting the importance of ascertaining the exact mechanisms underlying development of IH in AVF. Nonetheless, the results clearly illustrate the important role played by arterial curvature in determining AVF hemodynamics, which to our knowledge has been overlooked in all previous studies.

  2. A mathematical model of continuous arterio-venous hemodiafiltration (CAVHD)

    NARCIS (Netherlands)

    E. Akcahuseyin (Emin); H.H. Vincent (Jeroen); F.J. van Ittersum (Frans); W.A. van Duyl (Wim); M.A.D.H. Schalekamp (Maarten)

    1990-01-01

    textabstractAbstract Continuous arterio-venous hemodiafiltration (CAVHD) differs from conventional hemofiltration and dialysis by the interaction of convection and diffusion, the use of very low dialysate flow rates and by the deterioration of membrane conditions during the treatment. In order to st

  3. Arterio-venous malformations of uterus - diagnostic and management dilemmas.

    Science.gov (United States)

    Narang, H K; Puri, M; Patra, S; Trivedi, S S

    2015-01-01

    Keeping in mind the life-threatening consequences of curettage in cases of undiagnosed uterine arterio-venous malformation (AVM), its possibility should be considered in patients presenting with abnormal heavy uterine bleeding and negative Human Chorionic Gonadotropin (β-hCG) values. We collected a series of cases in which the patients presented with abnormal heavy uterine bleeding, some not responding to conservative treatment. In the presence of declining or low serum β-hCG levels and ultrasound Doppler showing increased vascularity, patients were investigated to detect the possible presence of uterine AVM. In those patients in whom angiographic confirmation of uterine AVM was made, embolisation was done and the outcome was followed. In those patients in whom hysterectomy was done the histopathogy specimen was studied for the possible cause of increased vascularity. Arterio-venous shunting seen on ultrasound does not always imply a uterine AVM and some cases can present diagnostic and management dilemmas.

  4. Intracranial dural arterio-venous fistula presenting with progressive myelopathy.

    LENUS (Irish Health Repository)

    Ogbonnaya, Ebere Sunny

    2011-01-01

    Spinal dural arterio-venous fistula (DAVF) is rare and usually involves the thoracic segments. The classical presentation is a slowly progressive ataxia. Clinical presentation of intracranial DAVF depends on the site of the DAVF, as well as the vessels involved. Patients may present with pulsatile tinnitus, occipital bruit, headache, dementia, visual impairment as well as neurological deterioration distant from the DAVF as a result of venous hypertension and cortical haemorrhage. The authors present a rare case of progressive myelopathy secondary to an intracranial DAVF.

  5. ARTERIO-VENOUS FISTULA IN THE TEMPORAL REGIONS – A CLINICAL CASE

    Directory of Open Access Journals (Sweden)

    Irina Dobrin

    2011-12-01

    Full Text Available The arterio-venous fistulae in the temporal regions, to be first described by Bartholin around 1730, were considered as tardy post-traumatic lesions correlated with the impact of tough objects in the above-mentioned area. The superficial temporal arterio-venous axis is usually interested at the level of the pterional region, while establishment of some communication between the artery and the vein generates an arterio-venous fistula with a systolodiastolic murmur and the tendency for progressive growth. The study discusses a clinical case and its surgical solution.

  6. Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion. Nonlinear decay of adult red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van; Wijngaard, Jeroen P H M van den [Laser Centre and Department of Obstetrics, Academic Medical Centre, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Pasman, Suzanne A; Vandenbussche, Frank P H A [Division of Fetal Medicine, Department of Obstetrics, Leiden University Medical Centre, Leiden (Netherlands); Lopriore, Enrico [Division of Neonatology, Department of Pediatrics, Leiden University Medical Centre, Leiden (Netherlands)], E-mail: m.j.vangemert@amc.uva.nl

    2008-07-07

    Recently, we derived equations relating the flow of adult red blood cells through a placental arterio-venous anastomosis with intra-uterine and post-natal measured adult hemoglobin concentrations. In this letter, we re-derived the equations, now including a more realistic nonlinear decay of adult red blood cells, and re-evaluated the measurement accuracy of the arterio-venous flow and the lifetime of the red blood cells. (letter to the editor)

  7. Arterio-venous balance studies of skeletal muscle fatty acid metabolism: what can we believe?

    OpenAIRE

    Guo, ZengKui; Jensen, Michael D

    2013-01-01

    The arterio-venous balance (A-V balance/difference) technique has been used by a number of groups, including ours, to study skeletal muscle fatty acid metabolism. Several lines of evidence indicate that, like glycogen, intramyocellular triglycerides (imcTG) are an energy source for local use. As such, the report that increased release of free fatty acids (FFA) via lipolysis from skeletal muscle, but not from adipose tissue, is responsible for the increased systemic lipolysis during IL-6 infus...

  8. Refashioning of an aneurysmatic arterio-venous fistula by using the multifire GIA 60 surgical stapler.

    Science.gov (United States)

    Hakim, N S; Romagnoli, J; Contis, J C; Akoh, J; Papalois, V E

    1997-01-01

    We describe a technique for refashioning an aneurysmatic arterio-venous fistula by using the multifire GIA 60 surgical stapler. After obtaining proximal and distal control of the aneurysmatic vein each aneurysmal segment of the anterior wall of the vein is excised by applying the GIA 60 stapler. The layer of the staple-line is re-enforced with one layer of 6/0 prolene continuous suture. After completion of the procedure, the size of the vein is reduced by approximately 50%. The AVFs were successfully re-used for dialysis within four weeks postoperatively.

  9. Monitoring arterio-venous differences of glucose and lactate in the anesthetized rat with or without brain damage with ultrafiltration and biosensor technology

    NARCIS (Netherlands)

    Leegsma-Vogt, G; Venema, K; Postema, F; Korf, J

    2001-01-01

    Continuous monitoring of arterio-venous glucose and lactate differences may serve as a diagnostic tool to assess normal brain function and brain pathology. We describe a method and some results obtained with arterio-venous measurements of glucose and lactate in the blood of the halothane-anesthetize

  10. Consensus Document of the International Union of Angiology (IUA)-2013. Current concept on the management of arterio-venous management

    NARCIS (Netherlands)

    Lee, B.B.; Baumgartner, I.; Berlien, H.P.; Bianchini, G.; Burrows, P.; Do, Y.S.; Ivancev, K.; Schultze Kool, L.J.; Laredo, J.; Loose, D.A.; Lopez-Gutierrez, J.C.; Mattassi, R.; Parsi, K.; Rimon, U.; Rosenblatt, M.; Shortell, C.; Simkin, R.; Stillo, F.; Villavicencio, L.; Yakes, W.

    2013-01-01

    Arterio-venous malformations (AVMs) are congenital vascular malformations (CVMs) that result from birth defects involving the vessels of both arterial and venous origins, resulting in direct communications between the different size vessels or a meshwork of primitive reticular networks of dysplastic

  11. The Effect of Arterial Curvature on Blood Flow in Arterio-Venous Fistulae: Realistic Geometries and Pulsatile Flow.

    Science.gov (United States)

    Grechy, L; Iori, F; Corbett, R W; Gedroyc, W; Duncan, N; Caro, C G; Vincent, P E

    2017-07-26

    Arterio-Venous Fistulae (AVF) are regarded as the "gold standard" method of vascular access for patients with End-Stage Renal Disease (ESRD) who require haemodialysis. However, up to 60% of AVF do not mature, and hence fail, as a result of Intimal Hyperplasia (IH). Unphysiological flow and oxygen transport patterns, associated with the unnatural and often complex geometries of AVF, are believed to be implicated in the development of IH. Previous studies have investigated the effect of arterial curvature on blood flow in AVF using idealized planar AVF configurations and non-pulsatile inflow conditions. The present study takes an important step forwards by extending this work to more realistic non-planar brachiocephalic AVF configurations with pulsatile inflow conditions. Results show that forming an AVF by connecting a vein onto the outer curvature of an arterial bend does not, necessarily, suppress unsteady flow in the artery. This finding is converse to results from a previous more idealized study. However, results also show that forming an AVF by connecting a vein onto the inner curvature of an arterial bend can suppress exposure to regions of low wall shear stress and hypoxia in the artery. This finding is in agreement with results from a previous more idealized study. Finally, results show that forming an AVF by connecting a vein onto the inner curvature of an arterial bend can significantly reduce exposure to high WSS in the vein. The results are important, as they demonstrate that in realistic scenarios arterial curvature can be leveraged to reduce exposure to excessively low/high levels of WSS and regions of hypoxia in AVF. This may in turn reduce rates of IH and hence AVF failure.

  12. Comparison of subjective and objective methods to determine the retinal arterio-venous ratio using fundus photography

    OpenAIRE

    Heitmar, Rebekka; Kalitzeos, Angelos A.; Patel, Sunni R.; Prabhu-Das, Diana; Cubbidge, Robert P.

    2015-01-01

    Purpose: To assess the inter and intra observer variability of subjective grading of the retinal arterio-venous ratio (AVR) using a visual grading and to compare the subjectively derived grades to an objective method using a semi-automated computer program. Methods: Following intraocular pressure and blood pressure measurements all subjects underwent dilated fundus photography. 86 monochromatic retinal images with the optic nerve head centred (52 healthy volunteers) were obtained using a Zeis...

  13. Arterio-venous balance studies of skeletal muscle fatty acid metabolism: what can we believe?

    Science.gov (United States)

    Guo, ZengKui

    2013-01-01

    The arterio-venous balance (A-V balance/difference) technique has been used by a number of groups, including ours, to study skeletal muscle fatty acid metabolism. Several lines of evidence indicate that, like glycogen, intramyocellular triglycerides (imcTG) are an energy source for local use. As such, the report that increased release of free fatty acids (FFA) via lipolysis from skeletal muscle, but not from adipose tissue, is responsible for the increased systemic lipolysis during IL-6 infusion in healthy humans is somewhat unexpected (26). It appears that given the complex anatomy of human limbs, as to be discussed in this review, it is virtually impossible to determine whether any fatty acids being released into the venous circulation of an arm or leg derive from the lipolysis of intermuscular fat residing between muscle groups, intramuscular fat residing within muscle groups (between epimysium and perimysium, or bundles), or the intramyocellular triglyceride droplets (imcTG). In many cases, it may even be difficult to be confident that there is no contribution of FFA from subcutaneous adipose tissue. This question is fundamentally important as one attempts to interpret the results of skeletal muscle fatty acid metabolism studies using the A-V balance technique. In this Perspectives article, we examine the reported results of fatty acid kinetics obtained using the techniques to evaluate the degree of and how to minimize contamination when attempting to sample skeletal muscle-specific fatty acids. PMID:23941872

  14. Adrift in the world of therapeutic apheresis: One center's experience in using arterio-venous fistulas during apheresis procedures.

    Science.gov (United States)

    Larson, Jennifer

    2016-10-01

    Therapeutic plasma exchange (TPE) is often an isolated specialty with very little research, especially in regard to the mode of access. This lack of information drove this attempt at reviewing the use of arterio-venous fistulas (AVF) in TPE, and specifically the issue of monitoring the accesses patency. Using a Transonic®, we attempted to obtain a reading, using the Spectra Optia™ on a patient's access. Unfortunately, due to the limitations of the equipment, we were unable to get a reading. Our conclusion is that we will have to monitor using other approaches, such as physical assessment and ultrasound.

  15. Arterio-venous fistula for automated red blood cells exchange in patients with sickle cell disease: Complications and outcomes.

    Science.gov (United States)

    Delville, Marianne; Manceau, Sandra; Ait Abdallah, Nassim; Stolba, Jan; Awad, Sameh; Damy, Thibaud; Gellen, Barnabas; Sabbah, Laurent; Debbache, Karima; Audard, Vincent; Beaumont, Jean-Louis; Arnaud, Cécile; Chantalat-Auger, Christelle; Driss, Françoise; Lefrère, François; Cavazzana, Marina; Franco, Gilbert; Galacteros, Frederic; Ribeil, Jean-Antoine; Gellen-Dautremer, Justine

    2017-02-01

    Erythrocytapheresis (ER) can improve outcome in patients with sickle cell disease (SCD). A good vascular access is required but frequently it can be difficult to obtain for sickle cell patients. Arterio-venous fistulas (AVFs) have been suggested for ER in SCD supported by limited evidence. We report the largest cohort of ER performed with AVFs from three French SCD reference centers. Data of SCD patients undergoing ER with AVFs in the French SCD reference center were retrospectively collected. The inclusion criteria were: SS or Sβ-Thalassemia and AVF surgery for ER. SCD-related complications, transfusion history, details about AVF surgical procedure, echocardiographic data before and after AVF, AVF-related surgical and hemodynamical complications were collected. Twenty-six patients (mean age 20.5 years, mean follow-up 68 months [11-279]) were included. Twenty-three patients (88.5%) required central vascular access before AVF. Fifteen AVFs (58%) were created on the forearm and 11 (42%) on the arm. Nineteen patients (73%) had stenotic, thrombotic or infectious AVF complications. A total of 0.36 stenosis per 1,000 AVF days, 0.37 thrombosis per 1,000 AVF days and 0.078 infections per 1.000 AVF days were observed. The mean AVF lifespan was 51 months [13-218]. One patient with severe pulmonary hypertension worsened after AVF creation and died. We report the first series of SCD patients with AVF for ER, demonstrating that AVFs could be considered as a potential vascular access for ER. Patients with increased risk for hemodynamic intolerance of AVFs must be carefully identified, so that alternative vascular accesses can be considered. Am. J. Hematol. 92:136-140, 2017. © 2016 Wiley Periodicals, Inc.

  16. Antithrombotic activity of F 16618, a new PAR1 antagonist evaluated in extracorporeal arterio-venous shunt in the rat.

    Science.gov (United States)

    Létienne, Robert; Leparq-Panissié, Anne; Calmettes, Yannick; Nadal-Wollbold, Florence; Perez, Michel; Le Grand, Bruno

    2010-06-01

    The purpose of the present work was the evaluation of the antithrombotic activity of a new PAR1 antagonist, F 16618 in arterio-venous shunt in the rat. Arterial thrombosis was induced by insertion of a silk thread (thrombogenic substrate) into an extracorporeal shunt. F 16618 was administered either by intravenous route (0.63-2.5mg/kg) or by oral route (20-80mg/kg). Oral activity of F 16618 was compared to that of aspirin (20-80mg/kg) and clopidogrel (0.63-10mg/kg). Finally, F 16618 was associated to aspirin and/or clopidogrel to test for possible antithrombotic activity and its effects on bleeding time. SFLLR-induced human platelet aggregation was evaluated in the presence of F 16618, demonstrating the anti-aggregant activity of this compound. F 16618 (1.25mg/kg) significantly delayed the time leading to occlusion by 52+/-17%, without affecting bleeding time and in absence of hemodynamic effects. F 16618 given orally dose-dependently increased the time to occlusion. The maximal effect was observed at 40mg/kg (984+/-95s versus 644+/-17s in vehicle group). Aspirin and clopidogrel also dose-dependently lengthened time to occlusion, but this effect was associated with an increase of bleeding time. F 16618 (20mg/kg) orally associated with either aspirin (40mg/kg) or with clopidogrel (1.25mg/kg) potentiated the antithrombotic effects of both compounds without further increasing of bleeding time. In conclusion, F 16618 exerted a potent antithrombotic activity by intravenous and oral routes, without affecting bleeding time. Furthermore, the antithrombotic activity was potentiated when combined with aspirin or clopidogrel.

  17. Association of Genetic Polymorphisms of Renin–Angiotensin–Aldosterone System-Related Genes with Arterio-Venous Fistula Malfunction in Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Yu-Wei Chen

    2016-05-01

    Full Text Available Hemodialysis (HD is the most commonly-used renal replacement therapy for patients with end-stage renal disease worldwide. Arterio-venous fistula (AVF is the vascular access of choice for HD patients with lowest risk of infection and thrombosis. In addition to environmental factors, genetic factors may also contribute to malfunction of AVF. Previous studies have demonstrated the effect of genotype polymorphisms of angiotensin converting enzyme on vascular access malfunction. We conducted a multicenter, cross-sectional study to evaluate the association between genetic polymorphisms of renin-angiotensin-aldosterone system and AVF malfunction. Totally, 577 patients were enrolled. Their mean age was 60 years old and 53% were male. HD patients with AVF malfunction had longer duration of HD (92.5 ± 68.1 vs. 61.2 ± 51.9 months, p < 0.001, lower prevalence of hypertension (44.8% vs. 55.3%, p = 0.025, right-sided (31.8% vs. 18.4%, p = 0.002 and upper arm AVF (26.6% vs. 9.7%, p < 0.001, and higher mean dynamic venous pressure (DVP (147.8 ± 28.3 vs. 139.8 ± 30.0, p = 0.021. In subgroup analysis of different genders, location of AVF and DVP remained significant clinical risk factors of AVF malfunction in univariate and multivariate binary logistic regression in female HD patients. Among male HD patients, univariate binary logistic regression analysis revealed that right-side AVF and upper arm location are two important clinical risk factors. In addition, two single nucleotide polymorphisms (SNPs, rs275653 (Odds ratio 1.90, p = 0.038 and rs1492099 (Odds ratio 2.29, p = 0.017 of angiotensin II receptor 1 (AGTR1, were associated with increased risk of AVF malfunction. After adjustment for age and other clinical factors, minor allele-containing genotype polymorphisms (AA and CA of rs1492099 still remained to be a significant risk factor of AVF malfunction (Odds ratio 3.63, p = 0.005. In conclusion, we demonstrated that rs1492099, a SNP of AGTR1 gene, could

  18. A new approach to non-invasive oxygenated mixed venous PCO(sub)2

    Science.gov (United States)

    Fisher, Joseph A.; Ansel, Clifford A.

    1986-01-01

    A clinically practical technique was developed to calculate mixed venous CO2 partial pressure for the calculation of cardiac output by the Fick technique. The Fick principle states that the cardiac output is equal to the CO2 production divided by the arterio-venous CO2 content difference of the pulmonary vessels. A review of the principles involved in the various techniques used to estimate venous CO2 partial pressure is presented.

  19. Estimating stroke volume from oxygen pulse during exercise.

    Science.gov (United States)

    Crisafulli, Antonio; Piras, Francesco; Chiappori, Paolo; Vitelli, Stefano; Caria, Marcello A; Lobina, Andrea; Milia, Raffaele; Tocco, Filippo; Concu, Alberto; Melis, Franco

    2007-10-01

    This investigation aimed at verifying whether it was possible to reliably assess stroke volume (SV) during exercise from oxygen pulse (OP) and from a model of arterio-venous oxygen difference (a-vO(2)D) estimation. The model was tested in 15 amateur male cyclists performing an exercise test on a cycle-ergometer consisting of a linear increase of workload up to exhaustion. Starting from the analysis of previous published data, we constructed a model of a-vO(2)D estimation (a-vO(2)D(est)) which predicted that the a-vO(2)D at rest was 30% of the total arterial O(2) content (CaO(2)) and that it increased linearly during exercise reaching a value of 80% of CaO(2) at the peak workload (W(max)) of cycle exercise. Then, the SV was calculated by applying the following equation, SV = OP/a-vO(2)D(est), where the OP was assessed as the oxygen uptake/heart rate. Data calculated by our model were compared with those obtained by impedance cardiography. The main result was that the limits of agreement between the SV assessed by impedance cardiography and the SV estimated were between 22.4 and -27.9 ml (+18.8 and -24% in terms of per cent difference between the two SV measures). It was concluded that our model for estimating SV during effort may be reasonably applicable, at least in a healthy population.

  20. Blood oxygen content in microliter samples using an easy-to-build galvanic oxygen cell.

    Science.gov (United States)

    Grubb, B R; Mills, C D

    1981-02-01

    We have designed a simple, inexpensive, easy-to-build and operate apparatus for measuring blood oxygen content. The galvanic oxygen cell (fuel cell) requires as little as 1 microliter of blood and has a measuring time of 1-3 min. It is well suited for measuring oxygen content in fluids low in oxygen inasmuch as the sensitivity of the instrument is variable. Either air or water (at a known temperature and oxygen tension) can be used for calibration. No significant differences in blood oxygen content measured with our cell or the Van Slyke manometric method were found.

  1. A Novel Electrochemical Oxygen Sensor for Determination of Ultra-low Oxygen Contents in Molten Metal

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A novel electrochemical oxygen sensor has been developed by using La-Al2O3 as solid electrolyte and Cr+Cr2O3 as reference electrode. The sensor not only can be used as normal oxygen sensor but also as an ultra-low oxygen sensor. Especially, it is very sensitive to measure ultra-low oxygen in molten metal. For estimating the accuracy of La-Al2O3 oxygen sensor, two series of oxygen activities in molten iron at different oxygen contents and different temperature were measured by both La-Al2O3 oxygen sensor and ZrO2 oxygen sensor. The theoretical values of oxygen activities in molten iron (3.30%C, in mass fraction) at 1723K and 1745K were also evaluated for comparing the measuring results of two sensors. At last, the error of measurement for La-Al2O3 oxygen sensor was discussed too.

  2. Endovascular management of intracranial pial arterio-venous fistulas.

    Science.gov (United States)

    Limaye, U S; Siddhartha, W; Shrivastav, M; Anand, S; Ghatge, S

    2004-03-01

    From 1996-2002 we treated 5 consecutive cases of pial fistula. There were 3 patients with a single hole-single channel pial fistula and two patients had a complex pial fistula. Three patients presented with intracerebral hematoma and had a focal neurological deficit. One patient presented with history of seizures and 1 patient had headache. The results of the treatment were analyzed both clinically and angiographically. The follow-up period ranged from 6 months to 6 years. All fistulas were treated with concentrated glue. The glue cast included the distal part of the feeding artery, A-V connection and the proximal part of the vein. Post-embolisation angiography showed complete occlusion of two single-hole fistulas and one complex pial A-V fistula and near total occlusion of one single-hole and one complex pial A-V fistula. Four patients had excellent clinical outcome. One patient with single-hole fistula had a hemorrhagic venous infarct resulting in transient hemiparesis.

  3. Arterio-venous fistula following a lumbar disc surgery

    Directory of Open Access Journals (Sweden)

    Thanyani V Mulaudzi

    2011-01-01

    Full Text Available Vascular complications during posterior lumbar disc surgery are rare and its presentation with varicose veins is even rarer. A 23 year-old male patient presented with large varicose veins in right lower limb. He underwent a posterior lumbar spine discectomy surgery. He noticed mild swelling of the distal third right lower limb 3 months after index surgery and reported 6 months later when he developed varicose veins. Duplex Doppler confirmed varicose veins of the long saphenous vein and its tributaries with a patent deep venous system. A digital subtraction angiogram demonstrated a large right common iliac artery (CIA false aneurysm with an arteriovenous fistula between right common iliac vessels. He had a right CIA covered stent insertion with good results. Varicose veins were later managed with sapheno-femoral junction ligation and a below knee long saphenous vein stripping. At six month follow-up the lower limb swelling had completely recovered and duplex ultrasound did not show any recurrence of varicose veins.

  4. Apneic oxygenation combined with extracorporeal arteriovenous carbon dioxide removal provides sufficient gas exchange in experimental lung injury

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Kjærgaard, Benedict; Nielsen, Jakob Koefoed

    Background and aim of study We hypothesized that continuous high airway pressure without ventilatory movements (apneic oxygenation), using an open lung approach, combined with extracorporeal, pumpless, arterio-venous, carbon dioxide (CO2) removal would provide adequate gas exchange in acute lung...... injury was induced by repeated lung lavage. Thereafter the tracheal tube was, after a lung recruitment maneuver, connected to 20 cmH2O continuous positive airway pressure (FiO2 = 1.0) for oxygenation of the blood. A pumpless membrane lung (Interventional Lung Assist, NovaLung, Germany) was connected...... In this porcine lung injury model, apneic oxygenation with arteriovenous CO2 removal provided sufficient gas exchange and stable hemodynamics, indicating that the method might have a potential in the treatment of severe ARDS.   Acknowledgements The membrane lungs were kindly provided by Novalung GmbH, Germany....

  5. Taken for Granted: Why Curriculum Content Is Like Oxygen

    Science.gov (United States)

    Gosse, Carolyn; Hansel, Lisa

    2014-01-01

    For educators, the content of the curriculum really is like oxygen: it is the necessary precondition for improving schools, closing the achievement gap, engaging parents, and preparing teachers. However, when educators take the content of the curriculum for granted, they lose opportunities to coordinate and collaborate. Good curriculum instruction…

  6. Apneic oxygenation combined with extracorporeal arteriovenous carbon dioxide removal provides sufficient gas exchange in experimental lung injury

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Kjærgaard, Benedict; Nielsen, Jakob Koefoed

    injury was induced by repeated lung lavage. Thereafter the tracheal tube was, after a lung recruitment maneuver, connected to 20 cmH2O continuous positive airway pressure (FiO2 = 1.0) for oxygenation of the blood. A pumpless membrane lung (Interventional Lung Assist, NovaLung, Germany) was connected......Background and aim of study We hypothesized that continuous high airway pressure without ventilatory movements (apneic oxygenation), using an open lung approach, combined with extracorporeal, pumpless, arterio-venous, carbon dioxide (CO2) removal would provide adequate gas exchange in acute lung...... injury. The aim of this study was to test this hypothesis in a lung injury model using pigs of human adult size, to mimic the O2 consumption and the CO2 production of adult patients.   Materials and methods In eight anesthetized, tracheally intubated and mechanically ventilated pigs (85-95 kg), lung...

  7. Influences of oxygen content on characteristics of atmospheric pressure dielectric barrier discharge in argon/oxygen mixtures

    Science.gov (United States)

    Fang, Zhi; Shao, Tao; Wang, Ruixue; Yang, Jing; Zhang, Cheng

    2016-04-01

    The dielectric barrier discharge generated in argon/oxygen mixtures at atmospheric pressure is investigated, and the effect of oxygen content on discharge characteristics at applied voltage of 4.5 kV is studied by means of electrical measurements and optical diagnostics. The results show that the filaments in the discharge regime become more densely packed with the increasing in the oxygen content, and the distribution of the filaments is more uniform in the gap. An increase in the oxygen content results in a decrease in the average power consumed and transported charges, while there exists an optimal value of oxygen content for the production of oxygen radicals. The maximal yield of oxygen radicals is obtained in mixtures of argon with 0.3% oxygen addition, and the oxygen radicals then decrease with the further increase in the oxygen content. The oxygen/argon plasma is employed to modify surface hydrophilicity of the PET films to estimate the influence of oxygen content on the surface treatment, and the static contact angles before and after the treatments are measured. The lowest contact angle is obtained at a 0.3% addition of oxygen to argon, which is in accordance with the optimum oxygen content for oxygen radicals generation. The electron density and electron temperature are estimated from the measured current and optical emission spectroscopy, respectively. The electron density is found to reduce significantly at a higher oxygen content due to the increased electron attachment, while the estimated electron temperature do not change apparently with the oxygen content. Contribution to the Topical Issue "Recent Breakthroughs in Microplasma Science and Technology", edited by Kurt Becker, Jose Lopez, David Staack, Klaus-Dieter Weltmann and Wei Dong Zhu.

  8. Relating oxygen partial pressure, saturation and content: the haemoglobin–oxygen dissociation curve

    Directory of Open Access Journals (Sweden)

    Julie-Ann Collins

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content, saturation (SO2 and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin–oxygen dissociation curve, a graphical representation of the relationship between oxygen satur­ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the SO2 in blood from patients with normal pH and SO2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (SpO2 is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (SaO2 as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable SpO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  9. Evidence for Argon Content in Pure Oxygen from Thermal Data

    Science.gov (United States)

    Steur, Peter P. M.; Yang, Inseok; Pavese, Franco

    2017-02-01

    Since many years it is known that argon impurities in oxygen change the temperature of the oxygen triple point by +12 K{\\cdot }mol^{-1} (positive, while most impurities decrease the temperature) without any effect on the melting range of this transition, for the impurity concentrations usually encountered in nominally pure gases. It has been hypothesized that thermal measurements on the α -β solid-to-solid transition at 23.8 K or the β -γ solid-to-solid transition at 43.8 K may give reliable evidence regarding the argon content. However, such measurements require very long times for full completion of each transition (with prohibitive costs if liquid helium is used) and for the α -β solid-to-solid transition the heat pulse method cannot be applied reliably. The availability of closed-cycle refrigerators permits the first obstacle to be surmounted. The automatic system earlier developed at INRIM during the EU Multicells project and used extensively for the project on the isotopic effect in neon is perfectly suited for such measurements. Thus, the uncertainties of the temperature measurements are similar to those obtained previously (of the order of 0.1 mK or less). Three argon-in-oxygen mixtures were prepared gravimetrically and certified at KRISS, just as was previously done for the work on the neon isotopic compositions. Results of continuous-current measurements on the α -β solid-to-solid transition, along with the triple-point data obtained with the heat pulse method, are presented for one cell with a known doped argon content, to be compared with similar data from a cell with oxygen of very high purity. In addition, some preliminary data for the β -γ solid-to-solid transition are given. The measurements on the mixture with the highest argon content, about 1002 μmol{\\cdot } mol^{-1}, imply a (linear) sensitivity of (116 ± 7) K{\\cdot }mol^{-1} for the α -β transition. This sensitivity may be different at much lower argon contents, and follow

  10. Total Hydrocarbon Content (THC) Testing in Liquid Oxygen (LOX)

    Science.gov (United States)

    Meneghelli, B. J.; Obregon, R. E.; Ross, H. R.; Hebert, B. J.; Sass, J. P.; Dirschka, G. E.

    2016-01-01

    The measured Total Hydrocarbon Content (THC) levels in liquid oxygen (LOX) systems at Stennis Space Center (SSC) have shown wide variations. Examples of these variations include the following: 1) differences between vendor-supplied THC values and those obtained using standard SSC analysis procedures; and 2) increasing THC values over time at an active SSC test stand in both storage and run vessels. A detailed analysis of LOX sampling techniques, analytical instrumentation, and sampling procedures will be presented. Additional data obtained on LOX system operations and LOX delivery trailer THC values during the past 12-24 months will also be discussed. Field test results showing THC levels and the distribution of the THC's in the test stand run tank, modified for THC analysis via dip tubes, will be presented.

  11. A modified procedure for measuring oxygen-18 content of nitrate

    Science.gov (United States)

    Ahmed, M. A.; Aly, A. I. M.; Abdel Monem, N.; Hanafy, M.; Gomaa, H. E.

    2012-11-01

    SummaryMass spectrometric analysis of O-isotopic composition of nitrate has many potential applications in studies of environmental processes. Through this work, rapid, reliable, precise, broadly applicable, catalyst-free, low-priced and less labor intensive procedure for measuring δ18O of nitrate using Isotope Ratio Mass Spectrometer has been developed and implemented. The conditions necessary to effect complete nitrate recovery and complete removal of other oxygen containing anions and dissolved organic carbon (DOC) without scarifying the isotopic signature of nitrate were investigated. The developed procedure consists of two main parts: (1) wet chemistry train for extraction and purification of nitrate from the liquid matrix; (2) off-line pyrolysis of extracted nitrate salt with activated graphite at 550 °C for 30 min. The conditions necessary to effect complete nitrate recovery and complete removal of other oxygen containing compounds were investigated. Dramatic reduction in processing times needed for analysis of δ18O of nitrate at natural abundance level was achieved. Preservation experiments revealed that chloroform (99.8%) is an effective preservative. Isotopic contents of some selected nitrate salts were measured using the modified procedure and some other well established methods at two laboratories in Egypt and Germany. Performance assessment of the whole developed analytical train was made using internationally distributed nitrate isotopes reference materials and real world sample of initial zero-nitrate content. The uncertainty budget was evaluated using the graphical nested hierarchal approach. The obtained results proved the suitability for handling samples of complicated matrices. Reduction of consumables cost by about 80% was achieved.

  12. Effect of oxygen content on tensile strength of polymer-derived SiC fibers

    Institute of Scientific and Technical Information of China (English)

    楚增勇; 冯春祥; 宋永才; 王应德; 李效东; 肖加余

    2002-01-01

    Air-curing is usually applied to the polymer-derived SiC fibers and, as a result, oxygen is embedded to the material. An effective relationship between oxygen content of the SiC fibers and mass gain of their precursor fibers was established. Results also showed that oxygen content has a great influence on the mechanical properties and excellent tensile strength is usually obtained at the oxygen content of 12%~13%, similar to the density of SiC fibers. Oxygen content has a positive effect on the ceramic yield, and thus, is good to the density and tensile strength; while, oxygen content is also negative to volume content of SiC phase and crystallization of the SiC fibers, and thus, detrimental to the density and tensile strength. Both of the two effects result in the peak behavior of the tensile strength of SiC fibers.

  13. Effects of Environmental Oxygen Content and Dissolved Oxygen on the Surface Tension and Viscosity of Liquid Nickel

    Science.gov (United States)

    SanSoucie, M. P.; Rogers, J. R.; Kumar, V.; Rodriguez, J.; Xiao, X.; Matson, D. M.

    2016-07-01

    The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has recently added an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled in the range from approximately 10^{-28} {to} 10^{-9} bar, while in a vacuum atmosphere. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, has a PID-based current loop and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects on surface tension and viscosity by oxygen partial pressure in the surrounding environment and the melt dissolved oxygen content will be evaluated, and the results will be presented. The surface tension and viscosity will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension and viscosity will be measured using the oscillating droplet method.

  14. [Russian oxygen generation system "Elektron-VM": hydrogen content in electrolytically produced oxygen for breathing by International Space Station crews].

    Science.gov (United States)

    Proshkin, V Yu; Kurmazenko, E A

    2014-01-01

    The article presents the particulars of hydrogen content in electrolysis oxygen produced aboard the ISS Russian segment by oxygen generator "Elektron-VM" (SGK) for crew breathing. Hydrogen content was estimated as in the course of SGK operation in the ISS RS, so during the ground life tests. According to the investigation of hydrogen sources, the primary path of H2 appearance in oxygen is its diffusion through the porous diaphragm separating the electrolytic-cell cathode and anode chambers. Effectiveness of hydrogen oxidation in the SGK reheating unit was evaluated.

  15. A Simple Experiment To Measure the Content of Oxygen in the Air Using Heated Steel Wool

    Science.gov (United States)

    Vera, Francisco; Rivera, Rodrigo; Nunez, Cesar

    2011-01-01

    The typical experiment to measure the oxygen content in the atmosphere uses the rusting of steel wool inside a closed volume of air. Two key aspects of this experiment that make possible a successful measurement of the content of oxygen in the air are the use of a closed atmosphere and the use of a chemical reaction that involves the oxidation of…

  16. Chemostratigraphies of carbon, oxygen and strontium isotopes and oxygen contents across the Precambrian-Cambrian boundary

    Science.gov (United States)

    Komiya, T.; Sawaki, Y.; Ishikawa, T.

    2007-12-01

    The Precambrian-Cambrian (PC-C) boundary is one of the most important intervals for evolution of life. However, the scarcity of well-preserved outcrops through the boundary makes it ambiguous to decode change of the surface environment and biological evolution. In south China, strata through the PC-C boundary are continuously exposed and contain many fossils, suitable for study of environmental and biological change. In addition, we conducted excavations at four sites of Three Gorge area to obtain continuous and fresh samples. We measured the delta13C, delta18O and 87Sr/86Sr values of the drill core samples and REE compositions of fresh carbonate rocks, respectively. We identified two positive and two negative isotope excursions of delta13Ccarb within this interval: a moderate increase from 0 to +2 permil and a subsequent dramatic drop to -7 permil at the PC-C boundary, and a continuous increase to +5 permil at the upper part of the Nemakit-Daldynian (ND) stage and the subsequent sharp decrease to -9 permil just below the basal Tommotian unconformity, respectively. The continuous pattern of the delta13C shift is irrespective of lithotype and is comparable to fragmented records of other sections within and outside of the Yangtze Platform, indicating that the profile represents global change of seawater chemistry. A chemostratigraphy of 87Sr/86Sr ratios of the drilled samples also displays a smooth curve and its large positive anomaly just below the PC-C boundary. The estimate of oxygen content of seawater from REE composition of carbonate minerals shows significant decreases around PC-C and ND-Tommotian boundaries, respectively. The combination of chemostratigraphies of delta13C, 87Sr/86Sr and pO2 indicates that the 87Sr/86Sr excursions preceded the delta13C negative excursion at PC-C boundary, and suggests that global regression or formation of the Gondwana supercontinent, evident in increase of influx of continental materials, caused biological depression together

  17. The effect of temperature and oxygen content on coal burnout

    Energy Technology Data Exchange (ETDEWEB)

    K. Milenkova; A.G. Borrego; D. Alvarez; J. Xiberta; R. Menendez [Instituto Nacional del Carbon, CSIC, Oviedo (Spain)

    2003-07-01

    In this study chars from six coals differing in rank and maceral composition have been prepared at 1100 and 1300{sup o}C in a drop tube reactor using four oxygen concentrations (0, 2.5, 10 and 21% oxygen). Char burnout, reactivity, morphology and optical texture have been considered in an attempt to understand the effect of temperature and oxygen concentration in relation to coal characteristics. Temperature has shown to have a different effect on conversion depending on coal rank. The high volatile coals showed similar conversions at 1100 and 1300{sup o}C at the various atmospheres tested, whereas higher rank coals showed higher conversions at 1300 than at 1100{sup o}C. The presence of oxygen in the reacting gas appears to have two opposite effects on coal combustion. On the one hand it prevents swelling and devolatilisation and on the other it enhances combustion. The burnout will depend on which process dominates. In addition, this effect appears to be temperature dependant and the inhibiting effect of oxygen on coal devolatilisation has shown to be higher at higher temperature, since at low temperature it only affects the lowest ranked coals. The presence of oxygen also affects the structure of carbonaceous material since the lower the oxygen concentration the higher the anisotropy development. The difference in temperature separating the two series of experiments (1000 and 1300{sup o}C) did not have a positive effect on the conversion of coals yielding highly porous chars whereas for coals yielding more dense structures higher conversions were achieved at higher temperatures. 7 refs., 5 figs., 1 tab.

  18. Cannulation strategies for percutaneous extracorporeal membrane oxygenation in adults.

    Science.gov (United States)

    Napp, L Christian; Kühn, Christian; Hoeper, Marius M; Vogel-Claussen, Jens; Haverich, Axel; Schäfer, Andreas; Bauersachs, Johann

    2016-04-01

    Extracorporeal membrane oxygenation (ECMO) has revolutionized treatment of severe isolated or combined failure of lung and heart. Due to remarkable technical development the frequency of use is growing fast, with increasing adoption by interventional cardiologists independent of cardiac surgery. Nevertheless, ECMO support harbors substantial risk such as bleeding, thromboembolic events and infection. Percutaneous ECMO circuits usually comprise cannulation of two large vessels ('dual' cannulation), either veno-venous for respiratory and veno-arterial for circulatory support. Recently experienced centers apply more advanced strategies by cannulation of three large vessels ('triple' cannulation), resulting in veno-veno-arterial or veno-arterio-venous cannulation. While the former intends to improve drainage and unloading, the latter represents a very potent method to provide circulatory and respiratory support at the same time. As such triple cannulation expands the field of application at the expense of increased complexity of ECMO systems. Here, we review percutaneous dual and triple cannulation strategies for different clinical scenarios of the critically ill. As there is no unifying terminology to date, we propose a nomenclature which uses "A" and all following letters for supplying cannulas and all letters before "A" for draining cannulas. This general and unequivocal code covers both dual and triple ECMO cannulation strategies (VV, VA, VVA, VAV). Notwithstanding the technical evolution, current knowledge of ECMO support is mainly based on observational experience and mostly retrospective studies. Prospective controlled trials are urgently needed to generate evidence on safety and efficacy of ECMO support in different clinical settings.

  19. Veno-venous extracorporeal membrane oxygenation: cannulation techniques

    Science.gov (United States)

    Banfi, Carlo; Pozzi, Matteo; Siegenthaler, Nils; Brunner, Marie-Eve; Tassaux, Didier; Obadia, Jean-Francois; Bendjelid, Karim

    2016-01-01

    The development of extracorporeal membrane oxygenation (ECMO) technology allows a new approach for the intensive care management of acute cardiac and/or respiratory failure in adult patients who are not responsive to conventional treatment. Current ECMO therapies provide a variety of options for the multidisciplinary teams who are involved in the management of these critically ill patients. In this regard, veno-venous ECMO (VV-ECMO) can provide quite complete respiratory support, even if this highly complex technique presents substantial risks, such as bleeding, thromboembolic events and infection. While VV-ECMO circuits usually include the cannulation of two vessels (double cannulation) in its classic configuration, the use of a single cannula is now possible for VV-ECMO support. Recently, experienced centers have employed more advanced approaches by cannulating three vessels (triple cannulation) which follows veno-arterio-venous (VAV) or veno-arterio-pulmonary-arterial cannulation (VAPa). However, ‘triple’ cannulation expands the field of application but increases the complexity of ECMO systems. In the present review, the authors focus on the indications for VV-ECMO, patient assessment prior to cannulation, the role of ultrasound-guided vessel puncture, double lumen single bicaval cannulations, and finally triple cannulation in VV-ECMO. PMID:28149575

  20. Adsorption of ionizable organic contaminants on multi-walled carbon nanotubes with different oxygen contents

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiaona; Zhao Huimin [Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Liaoning Province, Dalian 116024 (China); Quan Xie, E-mail: quanxie@dlut.edu.cn [Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Liaoning Province, Dalian 116024 (China); Chen Shuo; Zhang Yaobin; Yu Hongtao [Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Liaoning Province, Dalian 116024 (China)

    2011-02-15

    Multi-walled carbon nanotubes (MWNTs), which are considered to be promising candidates for the adsorption of toxic organics, are released into aqueous environment with their increasing production and application. In this study, the adsorption behaviors of five structurally related ionizable organic contaminants namely perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorooctanesulfonamide (PFOSA), 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-n-nonylphenol (4-NP) onto MWNTs with different oxygen contents (3.84-22.85%) were investigated. The adsorption kinetics was investigated and simulated with pseudo-second-order model. The adsorption isotherms were found to be fitted with Freundlich model and influenced by both the properties of organic chemicals and the oxygen contents of MWNTs. As adsorption capacity decreases dramatically with the increasing of oxygen contents, the MWNTs with the lowest oxygen contents possess the highest adsorption capacity among four MWNTs. For the MWNTs with the oxygen contents of 3.84%, the adsorption affinity related with hydrophobic interaction and {pi}-electron polarizability decreased in the order of 4-NP > PFOSA > PFOS > 2,4-D > PFOA. Furthermore, the adsorption characters of five contaminants were affected by solution pH and solute pK{sub a} considering electrostatic repulse force and hydrogen bonding, which showed the adsorption of MWNTs with lower oxygen content is much sensitive to solution chemistry.

  1. Relation between oxygen content and superconductivity in BiSrCaCuO system

    Science.gov (United States)

    Miura, N.; Deshimaru, Y.; Otani, T.; Shimizu, Y.; Yamazoe, N.

    1991-12-01

    Oxygen sorption-desorption behaviors as well as superconducting properties were examined for a series of 2212-isostructural oxides, Bi 2Sr 2-xCa 1+xCu 2O y ( x=0-1.0). It was found that oxygen sorption and desorption at temperatures below 600 °C brought about reversible shifts of Tc in a manner dependent on x. Quantitative determination of oxygen content (y) revealed that, as y decreased with oxygen desorption from the as-prepared levels, Tc increased monotonically for x=0 and 0.25, while it went through a maximum at y=8.15 for x=0.8.

  2. Structure Evolution of Graphene Oxide during Thermally Driven Phase Transformation: Is the Oxygen Content Really Preserved?

    CERN Document Server

    Sun, Pengzhan; Liu, He; Wang, Kunlin; Wu, Dehai; Xu, Zhiping; Zhu, Hongwei

    2014-01-01

    A mild annealing procedure was recently proposed for the scalable enhancement of graphene oxide (GO) properties with the oxygen content preserved, which was demonstrated to be attributed to the thermally driven phase separation. In this work, the structure evolution of GO with mild annealing is closely investigated. It reveals that in addition to phase separation, the transformation of oxygen functionalities also occurs, which leads to the slight reduction of GO membranes and further the enhancement of GO properties. These results are further supported by the density functional theory based calculations. The results also show that the amount of chemically bonded oxygen atoms on graphene decreases gradually and we propose that the strongly physisorbed oxygen species constrained in the holes and vacancies on GO lattice might be responsible for the preserved oxygen content during the mild annealing procedure. The present experimental results and calculations indicate that both the diffusion and transformation of...

  3. Relationship between oxygen content and seebeck coefficient of Bi-based superconducting oxides

    Science.gov (United States)

    Miura, N.; Sakata, F.; Shimizu, Y.; Deshimaru, Y.; Yamazoe, N.

    1994-12-01

    The correlations among Seebeck coefficient, oxygen content and superconducting property were examined for four Bi-based oxides (2223 and 2212 phases). Each oxide underwent reversible sorption and desorption of small amounts of oxygen (ca.3x10 -5mol/g) in the temperature range 100-600 °C. In good agreement with such behavior, the Seebeck coefficient (Q) of each oxide was found to change reversibly with changing temperature, suggesting that Q is a reversible function of oxygen content. It was further found that the highest Tc was reached at the oxygen content at which Q was incidentally brought to be around zero at 100 °C for each oxide.

  4. Dissolved oxygen content prediction in crab culture using a hybrid intelligent method

    Science.gov (United States)

    Yu, Huihui; Chen, Yingyi; Hassan, Shahbazgul; Li, Daoliang

    2016-06-01

    A precise predictive model is needed to obtain a clear understanding of the changing dissolved oxygen content in outdoor crab ponds, to assess how to reduce risk and to optimize water quality management. The uncertainties in the data from multiple sensors are a significant factor when building a dissolved oxygen content prediction model. To increase prediction accuracy, a new hybrid dissolved oxygen content forecasting model based on the radial basis function neural networks (RBFNN) data fusion method and a least squares support vector machine (LSSVM) with an optimal improved particle swarm optimization(IPSO) is developed. In the modelling process, the RBFNN data fusion method is used to improve information accuracy and provide more trustworthy training samples for the IPSO-LSSVM prediction model. The LSSVM is a powerful tool for achieving nonlinear dissolved oxygen content forecasting. In addition, an improved particle swarm optimization algorithm is developed to determine the optimal parameters for the LSSVM with high accuracy and generalizability. In this study, the comparison of the prediction results of different traditional models validates the effectiveness and accuracy of the proposed hybrid RBFNN-IPSO-LSSVM model for dissolved oxygen content prediction in outdoor crab ponds.

  5. INFLUENCE OF OZONE AERATION ON TOXIC METAL CONTENT AND OXYGEN ACTIVITY IN GREEN WASTE COMPOST

    Directory of Open Access Journals (Sweden)

    Maciej Gliniak

    2017-07-01

    Full Text Available This paper presents results of work on the reduction of toxic metal content while decreasing its oxygen activity. During the study the effects of different doses of ozone in the air used for aeration of the stabilized compost in the first post-thermophilic phase were analyzed. The results showed the possibility of reducing the concentrations of toxic metals and decrease the activity of oxygen up to 30% compared to traditional stabilized compost aeration system without using ozone.

  6. Decline in global oceanic oxygen content during the past five decades

    Science.gov (United States)

    Schmidtko, Sunke; Stramma, Lothar; Visbeck, Martin

    2017-02-01

    Ocean models predict a decline in the dissolved oxygen inventory of the global ocean of one to seven per cent by the year 2100, caused by a combination of a warming-induced decline in oxygen solubility and reduced ventilation of the deep ocean. It is thought that such a decline in the oceanic oxygen content could affect ocean nutrient cycles and the marine habitat, with potentially detrimental consequences for fisheries and coastal economies. Regional observational data indicate a continuous decrease in oceanic dissolved oxygen concentrations in most regions of the global ocean, with an increase reported in a few limited areas, varying by study. Prior work attempting to resolve variations in dissolved oxygen concentrations at the global scale reported a global oxygen loss of 550 ± 130 teramoles (1012 mol) per decade between 100 and 1,000 metres depth based on a comparison of data from the 1970s and 1990s. Here we provide a quantitative assessment of the entire ocean oxygen inventory by analysing dissolved oxygen and supporting data for the complete oceanic water column over the past 50 years. We find that the global oceanic oxygen content of 227.4 ± 1.1 petamoles (1015 mol) has decreased by more than two per cent (4.8 ± 2.1 petamoles) since 1960, with large variations in oxygen loss in different ocean basins and at different depths. We suggest that changes in the upper water column are mostly due to a warming-induced decrease in solubility and biological consumption. Changes in the deeper ocean may have their origin in basin-scale multi-decadal variability, oceanic overturning slow-down and a potential increase in biological consumption.

  7. Near-infrared spectroscopy measurement of blood oxygenation content and its application in sports practice

    Science.gov (United States)

    Xu, Guodong; Gong, Hui; Ge, Xinfa; Luo, Qingming

    2003-12-01

    To research the change characteristics of blood oxygenation content in skeletal muscle, the change regularity between blood oxygenation content and exercise intensity as well as HbO2 and blood lactate acid while taking incremental exercises, we took an in vivo, real-time and continuous measurement on the blood oxygenation content of eight sportsmen when they did incremental exercises of five degrees on a power bicycle using a portable tissue oximeter which is based on the principle of near-infrared spectroscopy(NIRS), simultaneously, we detected the blood lactate acid of subjects after each degree of incremental physical load instantly using a blood lactate analysis equipment. The results showed that the content of HbO2 descended regularly while that of Hb ascended; blood volume decreased; and the density of lactate increased as the intensity of exercises was heightened. The statistics analyses showed that the relationship between HbO2 and blood lactate is rather close (correlation coefficient r=-0.918). With this discovery, a theoretical basis in measuring the relative change of blood oxygenation content non-invasively was evidenced, and a novel technology for assessing the physical situation of sportsman, grasping sports density and evaluating the training effect could be imported.

  8. Value of Duplex Ultrasound Assistance for Thromboaspiration and Dilation of Thrombosed Native Arterio-Venous Fistulae

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Medina, J., E-mail: josegmedina57@gmail.com [Reina Sophia University Hospital, Vascular and Interventional Radiology Unit, Department of Radiology (Spain)

    2013-12-15

    Purpose: To evaluate the value of duplex ultrasound assistance during thromboaspiration of thrombosed arteriovenous fistulae for haemodialysis. Materials and Methods: We prospectively studied 54 thrombosed native fistulae (23 with total thrombosis and 31 with partial thrombosis), in which we performed manual thromboaspiration guided by ultrasonography associated with fluoroscopy. Results: The fistulae were located in the forearm (n = 39) or in the upper arm (n = 15) of 46 patients. Mean patient age was 65 years, and hypertension was the most common risk factor (74 %). Mean access age was 928 days (range 69-2,290), and most fistulae were on the left side (41 cases, 75.92 %). The success rate was 83 % in the total thrombosis group and 100 % in the partial thrombosis group. Including initial failures, the respective primary patency rates in the total thrombosis group and the partial thrombosis group were, respectively, 83 {+-} 8 % (n = 20) and 87 {+-} 6 % (n = 28) at 1 month, 39 {+-} 10 % (n = 10) and 61 {+-} 8 % (n = 20) at 6 months, and 17 {+-} 8 % (n = 5) and 26 {+-} 8 % (n = 9) at 1 year. The mean decrease of fluoroscopy time with ultrasound was 3 min (range 1-5). The mean decrease of radiation dose was 2.6 Gy cm Superscript-Two (range 0.9-4.3]. Conclusion: Ultrasound is a feasible and useful tool in the management of thrombosed native fistulae, thus decreasing radiation exposure, and has no detrimental effect on success rates.

  9. Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van; Wijngaard, Jeroen P H M van den [Laser Centre and Department of Obstetrics, Laser Center, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Lopriore, Enrico [Division of Neonatology, Department of Pediatrics, Leiden University Medical Centre, Leiden (Netherlands); Pasman, Suzanne A; Vandenbussche, Frank P H A [Division of Fetal Medicine, Department of Obstetrics, Leiden University Medical Centre, Leiden (Netherlands)], E-mail: m.j.vangemert@amc.uva.nl

    2008-04-07

    Twin-twin transfusion syndrome (TTTS) is a severe complication of monozygotic (identical) twin fetuses sharing one single (monochorionic) placenta. TTTS is caused by a net inter-twin transfusion of blood through placental anastomoses, from one twin (the donor) to the other (the recipient), which link the two feto-placental circulations. Currently, the only reliable method to measure the net inter-twin transfusion clinically is when incomplete laser therapy of TTTS occurs and one of the twins becomes anemic and requires an intra-uterine transfusion of adult red blood cells. Then, differences between adult hemoglobin concentrations measured during the transfusion and at birth relate not only to the net inter-twin transfusion but also to the finite lifetime of the adult red blood cells. We have analyzed this situation, derived the differential equations of adult hemoglobin in the donor and recipient twins, given the solutions and given expressions relating the net inter-twin flow with clinically measured parameters. We have included single and multiple intra-uterine transfusions. In conclusion, because incomplete laser therapy occurs frequently, and some cases require an intra-uterine transfusion, this method may allow collecting a wealth of net inter-twin flow data from clinicians involved in laser therapy of TTTS. To aid to the widespread use of this method, we have presented the equations as clearly as possible in tables for easy use by others. (note)

  10. ArterioVenous Malformation within Jejunal Diverticulum: An Unusual Cause of Massive Gastrointestinal Bleeding

    Directory of Open Access Journals (Sweden)

    Jeffrey K. Lee

    2009-01-01

    Full Text Available Massive gastrointestinal (GI bleeding can occur with multiple jejunal diverticulosis. However, significant bleeding in the setting of few diverticulae is very unusual and rare. We report a case of massive gastrointestinal bleeding from an arteriovenous malformation (AVM within a jejunal diverticulum to underscore the significance of such coexisting pathologies. Mesenteric angiogram was chosen to help identify the source of bleeding and to offer an intervention. Despite endovascular coiling, emergent intestinal resection of the bleeding jejunal segment was warranted to ensure definitive treatment. However several reports have shown jejunal diverticulosis as a rare cause of massive GI bleeding. The coexistence of jejunal diverticulum and AVM is rare and massive bleeding from an acquired Dieulafoy-like AVM within a diverticulum has never previously been described. Awareness of Dieulafoy-like AVM within jejunoileal diverticulosis is useful in preventing delay in treatment.

  11. NOTE: Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion

    Science.gov (United States)

    van Gemert, Martin J. C.; van den Wijngaard, Jeroen P. H. M.; Lopriore, Enrico; Pasman, Suzanne A.; Vandenbussche, Frank P. H. A.

    2008-04-01

    Twin-twin transfusion syndrome (TTTS) is a severe complication of monozygotic (identical) twin fetuses sharing one single (monochorionic) placenta. TTTS is caused by a net inter-twin transfusion of blood through placental anastomoses, from one twin (the donor) to the other (the recipient), which link the two feto-placental circulations. Currently, the only reliable method to measure the net inter-twin transfusion clinically is when incomplete laser therapy of TTTS occurs and one of the twins becomes anemic and requires an intra-uterine transfusion of adult red blood cells. Then, differences between adult hemoglobin concentrations measured during the transfusion and at birth relate not only to the net inter-twin transfusion but also to the finite lifetime of the adult red blood cells. We have analyzed this situation, derived the differential equations of adult hemoglobin in the donor and recipient twins, given the solutions and given expressions relating the net inter-twin flow with clinically measured parameters. We have included single and multiple intra-uterine transfusions. In conclusion, because incomplete laser therapy occurs frequently, and some cases require an intra-uterine transfusion, this method may allow collecting a wealth of net inter-twin flow data from clinicians involved in laser therapy of TTTS. To aid to the widespread use of this method, we have presented the equations as clearly as possible in tables for easy use by others.

  12. The upper arm arterio-venous fistula--an alternative for vascular access in haemodialysis

    DEFF Research Database (Denmark)

    Gade, J; Aabech, J; Hansen, R I

    1995-01-01

    Forty-eight consecutive arteriovenous fistulae of the upper arm constructed in 44 patients between 1983 and 1987 were reviewed. The median observation time was 8.5 months (range 1 day-65 months). The overall patency rate for fistulae used for haemodialysis (early failures excluded) was 50% after...... one year and 38% after two years. However, only six (18.7%) of the used fistulae stopped because of thrombosis. The total number of thromboses was nine (19.6%). The main cause of discontinuance of fistulae was a high number of deaths (n = 22), presumably a result of a high median age of 62 years....... Early failure rate was seven of 46 (15.2%); in three cases (6.5%) this was caused by thrombosis. The results are compared to other alternatives for radiocephalic fistulae and the difficulties of comparisons are discussed. It is concluded that the upper arm arteriovenous fistula can serve as a second...

  13. Amino acid uptake in arterio-venous serum of normal and cancerous colon tissues

    Institute of Scientific and Technical Information of China (English)

    Lin-Bo Wang; Jian-Guo Shen; Su-Zhan Zhang; Ke-Feng Ding; Shu Zheng

    2004-01-01

    AIM: To investigate the difference of amino acid uptake between normal and cancerous colon tissues.METHODS: Sixteen patients with colon cancer were enrolled in our study. Blood samples were taken during operations, serum amino acid concentrations of blood from cancerous or normal colon were analyzed. Amino acid uptake rate was calculated by the A-V difference and evaluated statistically.RESULTS: Except for methionine, the uptake rate of amino acids in cancer was higher than that in normal colon (25.01% vs-2.29%, P<0.01). The amino acid uptake rate did not correlate to the size of tumor mass (P>0.05). There was no statistical significance in the amino acid uptake rate according to the Dukes stage, though it was higher in patients with Dukes stage C or D than that with Dukes stage B (P>0.05).CONCLUSION: Abnormal synthetic metabolism of colon cancer may contribute to its higher amino acid uptake rate than that of normal colon.

  14. INFLUENCE OF ROOT OXYGEN DEFICIENCY ON PHOTOSYNTHESIS AND SACCHARIDE CONTENTS OF CAREX SPECIES

    NARCIS (Netherlands)

    MOOG, PR; BRUGGEMANN, W

    1993-01-01

    The responses to root oxygen deficiency concerning the photosynthesis, saccharide contents and mineral uptake have been investigated in Carex species, which were different in their anoxia-tolerance. The net rate of photosynthesis (P-N) of the anoxia-sensitive C. extensa was not affected by root anae

  15. Study on Oxygen Content, Inclusions and Fatigue Properties of Bearing Steels Produced by Different Processes

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The metallurgical properties and fatigue life of bearing steel processed by electric furnace (EAF), ladle refining (LF-VD), continuous casting (CC) and electroslag remelting (ESR) have been investigated. The main results obtained are as follows: (1) Due to low oxygen content and dispersion inclusions in steel, the fatigue life of LF-VD-IC or CC is three times as high as that of EAF steel; (2) The oxygen content in steel produced by CC process is about 9.0, the carbon segregation (C/C0) is from 0.92 to 1.10 and the fatigue life of CC steel is equal to that of ladle refining ingot casting steel; (3) Although the amount of inclusion and oxygen in ESR steel is higher than that of LF-VD-IC or CC steel, the fatigue life of ESR steel is higher than that of the latter because of its fine and well dispersed inclusions.

  16. Influence of Oxygen Content on the Superconductivity of Bi-Based Oxides Homologous to 2212 Phase

    Science.gov (United States)

    Deshimaru, Yuichi; Otani, Tetsuya; Shimizu, Youichi; Miura, Norio; Yamazoe, Noboru

    1991-10-01

    Thermal desorption of oxygen and its relevance to superconductivity were examined for a series of oxides Bi2Sr2-xCa1+xCu2Oy (x=0, 0.25, 0.5, 0.8 and 1.0) isostructural to the 2212 phase. The total oxygen desorbed up to 600°C amounted to 2˜ 3× 10-5 mol/g for each oxide. Tc was constant at about 80 K for all the as-prepared oxides but Tc decreased linearly with x from 97 K (x=0) to 67 K (x=1.0) for the oxygen-desorbed oxides. The total oxygen contents (y) were determined and correlated with Tc, which increased for x=0 and 0.25, whereas it went through a maximum at about y=8.15 for x=0.8.

  17. Relation between oxygen content and superconductivity in Bi-Sr-Ca-Cu-O system

    Energy Technology Data Exchange (ETDEWEB)

    Miura, N.; Deshimaru, Y.; Otani, T.; Shimizu, Y.; Yamazoe, N. (Dept. of Materials Science and Tech., Graduate School of Engineering Sciences, Kyushu Univ., Fukuoka (Japan))

    1991-12-01

    Oxygen sorption-desorption behaviors as well as superconducting properties were examined for a series of 2212-isostructural oxides, Bi{sub 2}Sr{sub 2-x}Ca{sub 1+x}Cu{sub 2}O{sub y} (x=0-1.0). It was found that oxygen sorption and desorption at temperatures below 600deg C brought about reversible shifts of Tc in a manner dependent on x. Quantitative determination of oxygen content (y) revealed that, as y decreased with oxygen desorption from the as-prepared levels, Tc increased montonically for x=0 and 0.25, while it went through a maximum at y=8.15 for x=0.8. (orig.).

  18. Effect of oxygen content on resistive switching memory characteristics of TiO{sub x} films

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Keun Yong; Park, Jae Hee; Kim, Sung; Choi, Suk Ho [Kyung Hee University, Yongin (Korea, Republic of)

    2012-03-15

    This work reports a strong oxygen-content dependence of the resistive switching characteristics in TiO{sub x} films grown by sputtering Ti under an oxygen ambient at flow rates (F{sub Q}) from 0.4 to 2.0 sccm. Remarkable improvements in the resistive switching parameters of the Al/TiO{sub x}/Pt memory devices, including dispersions of set/reset voltages, on/off ratio, and data retention, are obtained at F{sub Q} = 1.1 sccm. Based on the results of Rutherford backscattering and X-ray photoelectron spectroscopy, we show that the resistive switching characteristics of Al/TiO{sub x}/Pt devices are determined by the stoichiometry of the TiO{sub x} films and by the number of mobile oxygen ions in the films.

  19. Role of oxygen content on micro-whiskers in mercury based superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Aslan Çataltepe, Ö., E-mail: ozdenaslan@yahoo.com [Faculty of Engineering, Gedik University, 34876 İstanbul (Turkey); Güven Özdemir, Z. [Department of Physics, Yıldız Technical University, 34210 İstanbul (Turkey); Onbaşlı, Ü. [Department of Physics, Marmara University, Rıdvanpaşa cad.3.sok., 85/12, 34730 İstanbul (Turkey)

    2015-01-01

    In this study, the formation of micro-whiskers at the mercury based cuprate superconductors, synthesized by solid state reaction technique has been investigated for both oxygen and argon annealed samples. In this context, the superconducting samples have been annealed by the oxygen or argon gases in same rate (pressure) of 150 bar. Moreover, the over doped sample has been subjected to oxygen annealing twice at the same oxygen rate. Hence, micro-whiskers in the mercury cuprates have spontaneously grown for the over oxygen annealed sample, so we have not intended to have whisker grown. The whiskers grown in the mercury based cuprate superconductor has been investigated by Scanning Electron Microscopy, X-Ray Diffraction analysis and Superconducting Quantum Interference Devices measurements for the first time. It has been determined that whiskers grown on the over doped sample, which are in micrometer dimensions, have been observed only surfaces of the bulk sample. Moreover, the formation of whiskers has been examined for the optimally oxygen and argon doped samples. It has been shown that neither the optimally oxygen doped nor argon doped samples with the same gas rate have displayed any whisker structures. Hence, it has been decided that that the type of gas, the density of gas flowing and the bulk properties of the superconductor play a crucial role on formation of whisker structure in the system. Moreover, it has been revealed that in order to get rich whisker content, the oxygen process should be applied to the powder form of the superconductor in such a way to get the over oxygen doping rate for the superconducting system investigated. For further works, the magnetic and transport properties of the mercury based whiskers grown are planned to be determined. - Highlights: • Effect of gas type on whiskers has been investigated for Hg-based superconductor. • Concentration of the gas have a crucial role for whisker formation. • Shape of the superconducting

  20. Electrical conductivity of oxidized-graphenic nanoplatelets obtained from bamboo: effect of the oxygen content

    Science.gov (United States)

    Gross, K.; Prías Barragán, J. J.; Sangiao, S.; De Teresa, J. M.; Lajaunie, L.; Arenal, R.; Ariza Calderón, H.; Prieto, P.

    2016-09-01

    The large-scale production of graphene and reduced-graphene oxide (rGO) requires low-cost and eco-friendly synthesis methods. We employed a new, simple, cost-effective pyrolytic method to synthetize oxidized-graphenic nanoplatelets (OGNP) using bamboo pyroligneous acid (BPA) as a source. Thorough analyses via high-resolution transmission electron microscopy and electron energy-loss spectroscopy provides a complete structural and chemical description at the local scale of these samples. In particular, we found that at the highest carbonization temperature the OGNP-BPA are mainly in a sp2 bonding configuration (sp2 fraction of 87%). To determine the electrical properties of single nanoplatelets, these were contacted by Pt nanowires deposited through focused-ion-beam-induced deposition techniques. Increased conductivity by two orders of magnitude is observed as oxygen content decreases from 17% to 5%, reaching a value of 2.3 × 103 S m-1 at the lowest oxygen content. Temperature-dependent conductivity reveals a semiconductor transport behavior, described by the Mott three-dimensional variable range hopping mechanism. From the localization length, we estimate a band-gap value of 0.22(2) eV for an oxygen content of 5%. This investigation demonstrates the great potential of the OGNP-BPA for technological applications, given that their structural and electrical behavior is similar to the highly reduced rGO sheets obtained by more sophisticated conventional synthesis methods.

  1. Electrical conductivity of oxidized-graphenic nanoplatelets obtained from bamboo: effect of the oxygen content.

    Science.gov (United States)

    Gross, K; Barragán, J J Prías; Sangiao, S; De Teresa, J M; Lajaunie, L; Arenal, R; Calderón, H Ariza; Prieto, P

    2016-09-01

    The large-scale production of graphene and reduced-graphene oxide (rGO) requires low-cost and eco-friendly synthesis methods. We employed a new, simple, cost-effective pyrolytic method to synthetize oxidized-graphenic nanoplatelets (OGNP) using bamboo pyroligneous acid (BPA) as a source. Thorough analyses via high-resolution transmission electron microscopy and electron energy-loss spectroscopy provides a complete structural and chemical description at the local scale of these samples. In particular, we found that at the highest carbonization temperature the OGNP-BPA are mainly in a sp(2) bonding configuration (sp(2) fraction of 87%). To determine the electrical properties of single nanoplatelets, these were contacted by Pt nanowires deposited through focused-ion-beam-induced deposition techniques. Increased conductivity by two orders of magnitude is observed as oxygen content decreases from 17% to 5%, reaching a value of 2.3 × 10(3) S m(-1) at the lowest oxygen content. Temperature-dependent conductivity reveals a semiconductor transport behavior, described by the Mott three-dimensional variable range hopping mechanism. From the localization length, we estimate a band-gap value of 0.22(2) eV for an oxygen content of 5%. This investigation demonstrates the great potential of the OGNP-BPA for technological applications, given that their structural and electrical behavior is similar to the highly reduced rGO sheets obtained by more sophisticated conventional synthesis methods.

  2. Influence of intranasal and carotid cooling on cerebral temperature balance and oxygenation

    Directory of Open Access Journals (Sweden)

    Lars eNybo

    2014-02-01

    Full Text Available The present study evaluated the influence of intranasal cooling with balloon catheters, increased nasal ventilation, or percutaneous cooling of the carotid arteries on cerebral temperature balance and oxygenation in six healthy male subjects. Aortic arch and internal jugular venous blood temperatures were measured to assess the cerebral heat balance and corresponding paired blood samples were obtained to evaluate cerebral metabolism and oxygenation at rest, following 60 min of intranasal cooling, 5 min of nasal ventilation, and 15 min with carotid cooling. Intranasal cooling induced a parallel drop in jugular venous and arterial blood temperatures by 0.30 ± 0.08 ºC (mean ± SD, whereas nasal ventilation and carotid cooling failed to lower the jugular venous blood temperature. The magnitude of the arterio-venous temperature difference across the brain remained unchanged at - 0.33 ± 0.05 ºC following intranasal and carotid cooling, but increased to - 0.44 ± 0.11 ºC (P< 0.05 following nasal ventilation. Calculated cerebral capillary oxygen tension was 43 ± 3 mmHg at rest and remained unchanged during intranasal and carotid cooling, but decreased to 38 ± 2 mmHg (P< 0.05 following increased nasal ventilation. In conclusion, percutaneous cooling of the carotid arteries and intranasal cooling with balloon catheters are insufficient to influence cerebral oxygenation in normothermic subjects as the cooling rate is only 0.3 ºC per hour and neither intranasal nor carotid cooling is capable of inducing selective brain cooling.

  3. Methods for Eliminating Oxygen Content in Non-oxygenic Copper Stick%消除无氧铜棒材中氧含量超标的方法

    Institute of Scientific and Technical Information of China (English)

    王亚洲

    2012-01-01

    简述了无氧铜材中氧的来源,并根据长期的生产经验总结了无氧铜棒材中氧的分布规律及其影响因素,介绍了生产中降低和消除无氧铜棒材中氧含量的解决办法.%The source of oxygen in non-oxygenic copper was briefly expounded. Based on the long-term practical experience, the oxygen distribution rule and causes of non-oxygenic copper stick were concluded. The improvement measures and solution which can reduce and eliminate the oxygen content in non-oxygenic copper stick were introduced.

  4. High Stellar FUV/NUV Ratio and Oxygen Contents in the Atmospheres of Potentially Habitable Planets

    CERN Document Server

    Tian, Feng; Linsky, Jeffrey L; Mauas, Pablo J D; Vieytes, Mariela C

    2013-01-01

    Recent observations of several planet-hosting M dwarfs show that most have FUV/NUV flux ratios 1000 times greater than that of the Sun. Here we show that the atmospheric oxygen contents (O2 and O3) of potentially habitable planets in this type of UV environment could be 2~3 orders of magnitude greater than those of their counterparts around Sun-like stars as a result of decreased photolysis of O3, H2O2, and HO2. Thus detectable levels of atmospheric oxygen, in combination with the existence of H2O and CO2, may not be the most promising biosignatures on planets around stars with high FUV/NUV ratios such as the observed M dwarfs.

  5. Simulating the oxygen content of ambient organic aerosol with the 2D volatility basis set

    Science.gov (United States)

    Murphy, B. N.; Donahue, N. M.; Fountoukis, C.; Pandis, S. N.

    2011-08-01

    A module predicting the oxidation state of organic aerosol (OA) has been developed using the two-dimensional volatility basis set (2D-VBS) framework. This model is an extension of the 1D-VBS framework and tracks saturation concentration and oxygen content of organic species during their atmospheric lifetime. The host model, a one-dimensional Lagrangian transport model, is used to simulate air parcels arriving at Finokalia, Greece during the Finokalia Aerosol Measurement Experiment in May 2008 (FAME-08). Extensive observations were collected during this campaign using an aerosol mass spectrometer (AMS) and a thermodenuder to determine the chemical composition and volatility, respectively, of the ambient OA. Although there are several uncertain model parameters, the consistently high oxygen content of OA measured during FAME-08 (O:C = 0.8) can help constrain these parameters and elucidate OA formation and aging processes that are necessary for achieving the high degree of oxygenation observed. The base-case model reproduces observed OA mass concentrations (measured mean = 3.1 μg m-3, predicted mean = 3.3 μg m-3) and O:C (predicted O:C = 0.78) accurately. A suite of sensitivity studies explore uncertainties due to (1) the anthropogenic secondary OA (SOA) aging rate constant, (2) assumed enthalpies of vaporization, (3) the volatility change and number of oxygen atoms added for each generation of aging, (4) heterogeneous chemistry, (5) the oxidation state of the first generation of compounds formed from SOA precursor oxidation, and (6) biogenic SOA aging. Perturbations in most of these parameters do impact the ability of the model to predict O:C well throughout the simulation period. By comparing measurements of the O:C from FAME-08, several sensitivity cases including a high oxygenation case, a low oxygenation case, and biogenic SOA aging case are found to unreasonably depict OA aging, keeping in mind that this study does not consider possibly important processes

  6. Using an oxygen content indicator in a coal-dust boiler fuel controller

    Energy Technology Data Exchange (ETDEWEB)

    Y.V. Artamonov; V.N. Barbakov; A.E. Zemlyanoi; K.V. Soldatenko; Y.G. Metal' nikov [Novocherkassk State Regional Electric Power Plant, Novocherkassk (Russian Federation)

    2008-03-15

    The results of installing a circuit for regulating the fuel input to the 300 MW coal-dust power plant at the Novocherkassk State Regional Electric Power Plant (Novocherkasskaya GRES) based on an indicator of the oxygen content in the flue gases are described. The goal is to improve the quality of the controller response to perturbations in the fuel channel. The system and its structure are described, as well as transient control processes in the original and new systems in response to standard perturbations. The regulation quality is at least twice as good in the new scheme.

  7. In situ monitoring of the deformation mechanisms in titanium with different oxygen contents

    Energy Technology Data Exchange (ETDEWEB)

    Barkia, B. [Laboratoire de Mécanique des Solides, UMR 7649, CNRS, École Polytechnique, Palaiseau (France); Institut de Chimie et des Matériaux Paris-Est (ICMPE), UMR 7182, CNRS/UPEC, Thiais (France); Doquet, V. [Laboratoire de Mécanique des Solides, UMR 7649, CNRS, École Polytechnique, Palaiseau (France); Couzinié, J.P., E-mail: couzinie@icmpe.cnrs.fr [Institut de Chimie et des Matériaux Paris-Est (ICMPE), UMR 7182, CNRS/UPEC, Thiais (France); Guillot, I. [Institut de Chimie et des Matériaux Paris-Est (ICMPE), UMR 7182, CNRS/UPEC, Thiais (France); Héripré, E. [Laboratoire de Mécanique des Solides, UMR 7649, CNRS, École Polytechnique, Palaiseau (France)

    2015-06-11

    The deformation mechanisms of two titanium batches with different oxygen contents were monitored during tensile tests performed along the rolling and transverse directions under an optical or scanning electron microscope, after EBSD mappings of grain orientations. Whereas the contribution of mechanical twinning was very limited, grain boundary sliding, sometimes leading to intergranular decohesion, as well as kink bands formation were observed. Based on the identification of the primary slip traces in a significant number of grains, the critical resolved shear stresses (CRSSs) for prismatic, basal and π{sub 1}〈a〉 were estimated. Transmission electron microscopy was used to identify unambiguously dislocations of π{sub 1}〈c+a〉 systems and to estimate the corresponding CRSS. The difference in oxygen content between T40 and T60 was found to modify the magnitude of the CRSSs, but to leave their relative values nearly unchanged. The evolutions in the work hardening rate were correlated with the active deformation mechanisms.

  8. Effects of oxygen content on the electric and magnetic properties of BiFeO{sub 3} compound

    Energy Technology Data Exchange (ETDEWEB)

    Guilin, Song; Jian, Su; Zhang, Na; Fanggao, Chang, E-mail: sgl1972@yahoo.cn

    2016-07-15

    Multiferroic BiFeO{sub δ} (δ=2.67, 2.95 and 3.02) compound of various oxygen contents (δ) have been prepared by gel sol method. The influence of oxygen contents on the structure, electric and magnetic properties of BiFeO{sub 3} compound has been investigated. X-ray diffraction (XRD) measurements indicate that all the samples of BiFeO{sub δ} have the same crystal structure regardless of oxygen content. The SEM micrograph reveals microstructures comprising of grains with various sizes from 200 nm to 1 µm. XPS study confirms the coexistence of Fe{sup 3+} and Fe{sup 2+} ions in BiFeO{sub δ} compound. The M(H) curves exhibit weak ferromagnetic behavior with unsaturated magnetization at room temperature, independent of the oxygen content. The M(T) curves of suggest anti-ferromagnetic behavior with Neel temperature of ~370 °C for BiFeO{sub 2.95} and BiFeO{sub 3.02} samples and paramagnetic behavior of BiFeO{sub 2.67} sample from RT up to 500 °C. The experimental results show that the antiferromagnetic ordering is strongly correlated with the oxygen content and is almost entirely suppressed in BiFeO{sub δ} with δ=2.67. The effect of oxygen vacancies is to weaken the magnetic ordering rather than to enhance it as previously suggested in the literature.

  9. Simulating the oxygen content of ambient organic aerosol with the 2D volatility basis set

    Directory of Open Access Journals (Sweden)

    B. N. Murphy

    2011-08-01

    Full Text Available A module predicting the oxidation state of organic aerosol (OA has been developed using the two-dimensional volatility basis set (2D-VBS framework. This model is an extension of the 1D-VBS framework and tracks saturation concentration and oxygen content of organic species during their atmospheric lifetime. The host model, a one-dimensional Lagrangian transport model, is used to simulate air parcels arriving at Finokalia, Greece during the Finokalia Aerosol Measurement Experiment in May 2008 (FAME-08. Extensive observations were collected during this campaign using an aerosol mass spectrometer (AMS and a thermodenuder to determine the chemical composition and volatility, respectively, of the ambient OA. Although there are several uncertain model parameters, the consistently high oxygen content of OA measured during FAME-08 (O:C = 0.8 can help constrain these parameters and elucidate OA formation and aging processes that are necessary for achieving the high degree of oxygenation observed. The base-case model reproduces observed OA mass concentrations (measured mean = 3.1 μg m−3, predicted mean = 3.3 μg m−3 and O:C (predicted O:C = 0.78 accurately. A suite of sensitivity studies explore uncertainties due to (1 the anthropogenic secondary OA (SOA aging rate constant, (2 assumed enthalpies of vaporization, (3 the volatility change and number of oxygen atoms added for each generation of aging, (4 heterogeneous chemistry, (5 the oxidation state of the first generation of compounds formed from SOA precursor oxidation, and (6 biogenic SOA aging. Perturbations in most of these parameters do impact the ability of the model to predict O:C well throughout the simulation period. By comparing measurements of the O:C from FAME-08, several sensitivity cases including a high oxygenation case, a low oxygenation case, and biogenic SOA aging case are found to unreasonably depict OA aging, keeping in mind that this study does not consider

  10. Tc enhancement of excess Sr-doped Bi-2223 oxides by control of oxygen content

    Science.gov (United States)

    Miura, N.; Sakata, F.; Shimizu, Y.; Deshimaru, Y.; Yamazoe, N.

    1994-12-01

    The superconducting properties of excess Sr-doped 2223 phase samples, Bi 1.84Pb 0.34Sr 1.91+xCa 2.03Cu 3.06O y ( x=0.1, 0.3, 0.5, 1.0, 1.5), were examined. All the oxides as-prepared showed almost the same Tc of 109∼110 K, After heat-treatment in He at 600 °C for 3h, however, Tc increased up to 114∼115 K for the oxides with x=0.3∼, and decreased down to 102∼106 K for x=0∼0.1. The oxygen contents of the oxides as determined by iodometry increased with increasing x and slightly decreased with the heat-treatment in He. The heat treatment also brough about small increases in lattice constant of c-axis.

  11. SiC fiber with low electrical resistivity and oxygen content

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    A new SiC fiber was prepared by the pyrolysis of polycarbosilane(PCS) fiber cured with unsaturated hydrocarbons.The fiber,with oxygen content of 4-6 wt%,offers high tensile strength of 2.5-2.8 GPa.The electrical resistivity of the fiber is only about 0.5 Ω·cm,much lower than general SiC fiber obtained from traditional air curing process.Degradation of mechanical property in argon and air at high temperature is retarded by 200-300℃ with respect to the Nicalon NL-202 fiber.The low electrical resistivity of the fiber exhibits excellent thermal stability,it almost remains 0.4-0.8 Ω·cm after thermal exposure test from the room temperature to 1600℃ in argon.The low electrical resistivity mainly attribute to an excess carbon layer which is about 50 nm in the circular outer part.

  12. Reduced Cerebral Oxygen Content in the DG and SVZ In Situ Promotes Neurogenesis in the Adult Rat Brain In Vivo.

    Directory of Open Access Journals (Sweden)

    Kuan Zhang

    Full Text Available Neurogenesis in the adult brain occurs mainly within two neurogenic structures, the dentate gyrus (DG of the hippocampus and the sub-ventricular zone (SVZ of the forebrain. It has been reported that mild hypoxia promoted the proliferation of Neural Stem Cells (NSCsin vitro. Our previous study further demonstrated that an external hypoxic environment stimulated neurogenesis in the adult rat brain in vivo. However, it remains unknown how external hypoxic environments affect the oxygen content in the brain and result in neurogenesis. Here we use an optical fiber luminescent oxygen sensor to detect the oxygen content in the adult rat brain in situ under normoxia and hypoxia. We found that the distribution of oxygen in cerebral regions is spatiotemporally heterogeneous. The Po2 values in the ventricles (45∼50 Torr and DG (approximately 10 Torr were much higher than those of other parts of the brain, such as the cortex and thalamus (approximately 2 Torr. Interestingly, our in vivo studies showed that an external hypoxic environment could change the intrinsic oxygen content in brain tissues, notably reducing oxygen levels in both the DG and SVZ, the major sites of adult neurogenesis. Furthermore, the hypoxic environment also increased the expression of HIF-1α and VEGF, two factors that have been reported to regulate neurogenesis, within the DG and SVZ. Thus, we have demonstrated that reducing the oxygen content of the external environment decreased Po2 levels in the DG and SVZ. This reduced oxygen level in the DG and SVZ might be the main mechanism triggering neurogenesis in the adult brain. More importantly, we speculate that varying oxygen levels may be the physiological basis of the regionally restricted neurogenesis in the adult brain.

  13. Reduced Cerebral Oxygen Content in the DG and SVZ In Situ Promotes Neurogenesis in the Adult Rat Brain In Vivo.

    Science.gov (United States)

    Zhang, Kuan; Zhou, Yanzhao; Zhao, Tong; Wu, Liying; Huang, Xin; Wu, Kuiwu; Xu, Lun; Li, Dahu; Liu, Shuhong; Zhao, Yongqi; Fan, Ming; Zhu, Lingling

    2015-01-01

    Neurogenesis in the adult brain occurs mainly within two neurogenic structures, the dentate gyrus (DG) of the hippocampus and the sub-ventricular zone (SVZ) of the forebrain. It has been reported that mild hypoxia promoted the proliferation of Neural Stem Cells (NSCs)in vitro. Our previous study further demonstrated that an external hypoxic environment stimulated neurogenesis in the adult rat brain in vivo. However, it remains unknown how external hypoxic environments affect the oxygen content in the brain and result in neurogenesis. Here we use an optical fiber luminescent oxygen sensor to detect the oxygen content in the adult rat brain in situ under normoxia and hypoxia. We found that the distribution of oxygen in cerebral regions is spatiotemporally heterogeneous. The Po2 values in the ventricles (45∼50 Torr) and DG (approximately 10 Torr) were much higher than those of other parts of the brain, such as the cortex and thalamus (approximately 2 Torr). Interestingly, our in vivo studies showed that an external hypoxic environment could change the intrinsic oxygen content in brain tissues, notably reducing oxygen levels in both the DG and SVZ, the major sites of adult neurogenesis. Furthermore, the hypoxic environment also increased the expression of HIF-1α and VEGF, two factors that have been reported to regulate neurogenesis, within the DG and SVZ. Thus, we have demonstrated that reducing the oxygen content of the external environment decreased Po2 levels in the DG and SVZ. This reduced oxygen level in the DG and SVZ might be the main mechanism triggering neurogenesis in the adult brain. More importantly, we speculate that varying oxygen levels may be the physiological basis of the regionally restricted neurogenesis in the adult brain.

  14. Tailoring the Oxygen Content of Graphite and Reduced Graphene Oxide for Specific Applications

    Science.gov (United States)

    Morimoto, Naoki; Kubo, Takuya; Nishina, Yuta

    2016-02-01

    Graphene oxide (GO) is widely recognized as a promising material in a variety of fields, but its structure and composition has yet to be fully controlled. We have developed general strategies to control the oxidation degree of graphene-like materials via two methods: oxidation of graphite by KMnO4 in H2SO4 (oGO), and reduction of highly oxidized GO by hydrazine (rGO). Even though the oxygen content may be the same, oGO and rGO have different properties, for example the adsorption ability, oxidation ability, and electron conductivity. These differences in property arise from the difference in the underlying graphitic structure and the type of defect present. Our results can be used as a guideline for the production of tailor-made graphitic carbons. As an example, we show that rGO with 23.1 wt% oxygen showed the best performance as an electrode of an electric double-layer capacitor.

  15. Plasma ATP concentration and venous oxygen content in the forearm during dynamic handgrip exercise

    Directory of Open Access Journals (Sweden)

    Askew Christopher D

    2009-12-01

    Full Text Available Abstract Background It has been proposed that adenosine triphosphate (ATP released from red blood cells (RBCs may contribute to the tight coupling between blood flow and oxygen demand in contracting skeletal muscle. To determine whether ATP may contribute to the vasodilatory response to exercise in the forearm, we measured arterialised and venous plasma ATP concentration and venous oxygen content in 10 healthy young males at rest, and at 30 and 180 seconds during dynamic handgrip exercise at 45% of maximum voluntary contraction (MVC. Results Venous plasma ATP concentration was elevated above rest after 30 seconds of exercise (P Conclusions Collectively these results indicate that ATP in the plasma originated from the muscle microcirculation, and are consistent with the notion that deoxygenation of the blood perfusing the muscle acts as a stimulus for ATP release. That ATP concentration was elevated just 30 seconds after the onset of exercise also suggests that ATP may be a contributing factor to the blood flow response in the transition from rest to steady state exercise.

  16. Atrial supply-demand balance in healthy adult pigs: coronary blood flow, oxygen extraction, and lactate production during acute atrial fibrillation.

    Science.gov (United States)

    van Bragt, Kelly A; Nasrallah, Hussein M; Kuiper, Marion; Luiken, Joost J; Schotten, Ulrich; Verheule, Sander

    2014-01-01

    Little is known about how atrial oxygen supply responds to increased demand, and under which conditions it falls short (supply-demand mismatch). Here, we have investigated the vasodilator response, oxygen extraction, and lactate production of the left atrium (LA) and left ventricle (LV) in response to atrial pacing and atrial fibrillation (AF). Series A (n = 9 Dutch landrace pigs) was instrumented to measure LA and LV vascular conductance in branches of the circumflex artery. Coronary conductance reserve (CCR) was calculated as the ratio between conductance during adenosine infusion and baseline. Series B (n = 7) was instrumented with sampling catheters in LA and LV veins for determination of blood gases and lactate levels. LA CCR (1.76 ± 0.14) was significantly lower than LV CCR (3.16 ± 0.27, P = 0.002). However, basal oxygen extraction was lower in LA (27 ± 3%) than that in the LV (58 ± 6%, P = 0.0006), indicating a larger extraction reserve in the LA than that in the LV (4.68 ± 0.84 vs. 1.88 ± 0.26, P = 0.01). Atrial pacing caused an increase in LA conductance (Series A) and oxygen extraction (Series B). AF increased LA vascular conductance to 177 ± 14% at 1 min, 168 ± 14 at 5 min, and 164 ± 31% at 10 min of AF (P < 0.05 vs. baseline). Atrial oxygen extraction also increased from 26 ± 3% at baseline to 63 ± 5% (P < 0.01) at 5 min and 60 ± 11% (P < 0.01) at 10 min of AF. Arterio-venous lactate difference increased significantly (P = 0.02) during AF. In healthy pigs, the LA has a lower CCR, but a higher extraction reserve compared with the LV. Although both reserves were recruited during AF, atrial lactate production increased significantly.

  17. Effect of oxygen content on the structural and optical properties of ZnO films grown by atmospheric pressure MOCVD

    Institute of Scientific and Technical Information of China (English)

    Sajjad Hussain; Yaqoob Khan; Volodymyr Khranovskyy; Riaz Muhammad; Rositza Yakimova

    2013-01-01

    Atmospheric pressure MOCVD was used to deposit ZnO layers on sapphire and homoepitaxial template under different oxygen flow rates. Oxygen content affects the lattice constant value and texture coefficient of the films as evidenced by the y-2y peaks position and their intensity. Films deposited at lower oxygen flow rate possess higher value of strain and stresses. ZnO films deposited at high oxygen flow rates show intense UV emissions while samples prepared under oxygen deficient conditions exhibited defect related emission along with UV luminescence. The results are compared to the ZnO films deposited homoepitaxially on annealed ZnO samples. The data obtained suggest that ZnO stoichiometry is responsible for the structural and optical quality of ZnO films.

  18. The impact of including spatially longitudinal heterogeneities of vessel oxygen content and vascular fraction in 3D tumor oxygenation models on predicted radiation sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Lagerlöf, Jakob H., E-mail: Jakob@radfys.gu.se [Department of Radiation Physics, Göteborg University, Göteborg 41345 (Sweden); Kindblom, Jon [Department of Oncology, Sahlgrenska University Hospital, Göteborg 41345 (Sweden); Bernhardt, Peter [Department of Radiation Physics, Göteborg University, Göteborg 41345, Sweden and Department of Nuclear Medicine, Sahlgrenska University Hospital, Göteborg 41345 (Sweden)

    2014-04-15

    necrotic fraction and D{sub 99}, necrotic fractions ranging from 0% to 97%, and a maximal D{sub 99} increment of 57%. Only minor differences were observed between different vessel architectures, i.e., CVF vs VVF. In the smallest tumor with a low necrotic fraction, the D{sub 99} strictly decreased with increasing blood velocity. Increasing blood velocity also decreased the necrotic fraction in all tumor sizes. VF had the most profound influence on both the necrotic fraction and on D{sub 99}. Conclusions: Our present analysis of necrotic formation and the impact of tumor oxygenation on D{sub 99} demonstrated the importance of including longitudinal variations in vessel oxygen content in tumor models. For small tumors, radiosensitivity was particularly dependent on VF and slightly dependent on the blood velocity and vessel arrangement. These dependences decreased with increasing tumor size, because the necrotic fraction also increased, thereby decreasing the number of viable tumor cells that required sterilization. The authors anticipate that the present model will be useful for estimating tumor oxygenation and radiation response in future detailed studies.

  19. Dissolved oxygen content in apple must: technological implications in cider processing

    National Research Council Canada - National Science Library

    Alberti, Aline; Braga, Cíntia Maia; Jaster, Henrique; Nogueira, Alessandro

    2014-01-01

    Oxygen can influence the composition and quality of apple must and cider. In this study, the effect of unit operations on oxygen dissolution during apple must processing was investigated and the technological implications discussed...

  20. The vitamin C content of orange juice packed in an oxygen scavenger material

    NARCIS (Netherlands)

    Zerdin, K.; Rooney, M.L.; Vermuë, J.

    2003-01-01

    A storage study of orange juice packed in oxygen scavenging (OS) film and oxygen barrier film was conducted to determine the extent of ascorbic acid loss due to oxygen as a function of time and temperature. The initial concentration of ascorbic acid in the orange juice was 374 mg/l and this was foun

  1. The vitamin C content of orange juice packed in an oxygen scavenger material

    NARCIS (Netherlands)

    Zerdin, K.; Rooney, M.L.; Vermuë, J.

    2003-01-01

    A storage study of orange juice packed in oxygen scavenging (OS) film and oxygen barrier film was conducted to determine the extent of ascorbic acid loss due to oxygen as a function of time and temperature. The initial concentration of ascorbic acid in the orange juice was 374 mg/l and this was

  2. Polymer-derived silicon carbide fibers with near-stoichiometric composition and low oxygen content

    Energy Technology Data Exchange (ETDEWEB)

    Sacks, M.D.; Scheiffele, G.W.; Saleem, M.; Staab, G.A.; Morrone, A.A.; Williams, T.J. [Univ. of Florida, Gainesville, FL (United States). Dept. of Materials Science and Engineering

    1995-10-01

    Fine-diameter ({approximately} 10--15 {micro}m), polymer-derived SiC fibers were characterized. The average tensile strength of the fibers was {approximately} 2.8 GPa, although some lots had average strengths exceeding 3.5 GPa. Microstructure observations showed that fibers had fine grain sizes (mostly {approximately} 0.05--0.2 {micro}m), high densities ({approximately} 3.1--3.2 g/cm{sup 3}), and small residual pore sizes ({le} 0.1 {micro}m). Elemental analysis showed that fibers had near-stoichiometric composition. Electron and X-ray diffraction analyses indicated that fibers were primarily beta silicon carbide, with a minor amount of the alpha phase. A small amount of graphitic carbon was detected in some samples using high resolution transmission electron microscopy. The residual oxygen content in the fibers was {le} 0.1 wt%. Fibers exhibited good thermomechanical stability, as heat treatment at 1,800 C for 4 h in argon resulted in only an {approximately} 8% decrease in strength.

  3. Investigation of the Effects of Oxygen Content in YBa2Cu3Ox on the Depth and Profile of Direct Ion Milled Trenches

    Science.gov (United States)

    2014-09-01

    TECHNICAL REPORT 2049 September 2014 Investigation of the Effects of Oxygen Content in YBa2Cu3Ox on the Depth and Profile of...92152-5001 TECHNICAL REPORT 2049 September 2014 Investigation of the Effects of Oxygen Content in YBa2Cu3Ox on the Depth and Profile...temperature Tc at which the material becomes superconducting . In the case of YBa2Cu3Ox, (6 ≤ x ≤ 7), the structure is such that oxygen content varies within

  4. Influence of the Oxygen content on the thermal migration of Xenon in ZrCxO1-x

    Science.gov (United States)

    Pipon, Y.; Toulhoat, N.; Moncoffre, N.; Gutierrez, G.; Maître, A.; Gendre, M.

    2013-09-01

    Zirconium carbide (ZrC) is a refractory ceramic presenting interesting properties such as a high melting point, a very high hardness and a good thermal stability. For these reasons, this material is considered as a candidate for fuel coating for fourth-generation reactors in particular for the Gas cooled Fast Reactors (GFR). The ceramic temperature could reach 1200 °C in normal reactor operation and reach 1700 °C in accidental conditions. It is therefore important to assess the ZrC thermal retention capacity regarding abundant and/or volatile fission products. This paper deals with the behavior of Xenon which is the major gaseous fission product created during fission. Previous studies have shown that Xenon remained motionless in an "Oxygen-poor" matrix such as ZrC0.95O0.05, up to temperatures of 1800 °C. However, Zirconium oxycarbides are known to be very sensitive to oxidation. This study aims therefore at studying the behavior of Xenon in Zirconium oxycarbide samples with different Oxygen contents. Xenon is introduced by ion implantation and the samples are annealed in secondary vacuum in the temperature range 1400 °C-1800 °C. The Oxygen profiles are determined by using the 16O(4He, 4He)16O nuclear reaction at 7.5 MeV and the concentration profiles of Xenon are measured by Rutherford Backscattering Spectrometry at each step of the treatment. The results show that the behavior of the material during annealing with respect to oxidation is strongly related to its initial Oxygen content. More generally, the higher the initial Oxygen content, the more important is the oxidation. Consequently, the Xenon migration is enhanced in Oxygen rich Zirconium carbides. at 1950 °C under vacuum with an applied load of 100 MPa by Spark Plasma Sintering (SPS) at the University of Toulouse (CNRS PNF2 platform) [22]. at 1845 °C under an Ar gas flow with an applied load of 40 MPa by Hot Pressing (HP) at Limoges. Sintered pellets were divided into two batches: (i) a batch of

  5. Effect of initial oxygen content on the void swelling behavior of fast neutron irradiated copper

    Energy Technology Data Exchange (ETDEWEB)

    Zinkle, S.J. [Oak Ridge National Lab., TN (United States); Garner, F.A. [Pacific Northwest National Lab., Richland, WA (United States)

    1998-03-01

    Density measurements were performed on high purity copper specimens containing {le}10 wt.ppm and {approximately}120 wt.ppm oxygen following irradiation in FFTF MOTA 2B. Significant amounts of swelling were observed in both the oxygen-free and oxygen-doped specimens following irradiation to {approximately}17 dpa at 375 C and {approximately}47 dpa at 430 C. Oxygen doping up to 360 appm (90 wt.ppm) did not significantly affect the void swelling of copper for these irradiation conditions.

  6. Zero added oxygen for high quality sputtered ITO: A data science investigation of reduced Sn-content and added Zr

    Energy Technology Data Exchange (ETDEWEB)

    Peshek, Timothy J. [The School for the Engineering of Matter, Transport and Energy, Arizona State University, Tempe, Arizona 85287 and The National Center for Photovoltaics, The National Renewable Energy Laboratory, Golden, Colorado 80401 (United States); Burst, James M.; Coutts, Timothy J.; Gessert, Timothy A., E-mail: tjp3@case.edu [The National Center for Photovoltaics, The National Renewable Energy Laboratory, Golden, Colorado 80401 (United States)

    2016-03-15

    The authors demonstrate mobilities of >45 cm{sup 2}/V s for sputtered tin-doped indium oxide (ITO) films at zero added oxygen. All films were deposited with 5 wt. % SnO{sub 2}, instead of the more conventional 8–10 wt. %, and had varying ZrO{sub 2} content from 0 to 3 wt. %, with a subsequent reduction in In{sub 2}O{sub 3} content. These films were deposited by radio-frequency magnetron sputtering from nominally stoichiometric targets with varying oxygen partial pressure in the sputter ambient. Anomalous behavior was discovered for films with no Zr-added, where a bimodality of high and low mobilities was discovered for nominally similar growth conditions. However, all films showed the lowest resistivity and highest mobilities when the oxygen partial pressure in the sputter ambient was zero. This result is contrasted with several other reports of ITO transport performance having a maximum for small but nonzero oxygen partial pressure. This result is attributed to the reduced concentration of SnO{sub 2}. The addition of ZrO{sub 2} yielded the highest mobilities at >55 cm{sup 2}/V s and the films showed a modest increase in optical transmission with increasing Zr-content.

  7. Hot-wire chemical vapor deposition of WO{sub 3−x} thin films of various oxygen contents

    Energy Technology Data Exchange (ETDEWEB)

    Houweling, Z. Silvester, E-mail: Silvester.Houweling@asml.com [Section Nanophotonics – Physics of Devices, Debye Institute for Nanomaterials Science, Utrecht University, Princetonlaan 4, 3584 CC Utrecht (Netherlands); Geus, John W. [Inorganic Chemistry and Catalysis, Utrecht University, Padualaan 8, 3584 CH Utrecht (Netherlands); Schropp, Ruud E.I. [Section Nanophotonics – Physics of Devices, Debye Institute for Nanomaterials Science, Utrecht University, Princetonlaan 4, 3584 CC Utrecht (Netherlands)

    2013-06-15

    We present the synthesis of tungsten oxide (WO{sub 3−x}) thin films consisting of layers of varying oxygen content. Configurations of layered thin films comprised of W, W/WO{sub 3−x}, WO{sub 3}/W and WO{sub 3}/W/WO{sub 3−x} are obtained in a single continuous hot-wire chemical vapor deposition process using only ambient air and hydrogen. The air oxidizes resistively heated tungsten filaments and produces the tungsten oxide species, which deposit on a substrate and are subsequently reduced by the hydrogen. The reduction of tungsten oxides to oxides of lower oxygen content (suboxides) depends on the local water vapor pressure and temperature. In this work, the substrate temperature is either below 250 °C or is kept at 750 °C. A number of films are synthesized using a combined air/hydrogen flow at various total process pressures. Rutherford backscattering spectrometry is employed to measure the number of tungsten and oxygen atoms deposited, revealing the average atomic compositions and the oxygen profiles of the films. High-resolution scanning electron microscopy is performed to measure the physical thicknesses and display the internal morphologies of the films. The chemical structure and crystallinity are investigated with Raman spectroscopy and X-ray diffraction, respectively. - Highlights: • Synthesis of tungsten oxide thin films of controllable oxygen content. • Partial reduction of WO{sub 3−x} thin films during deposition. • Deposition of layered films with configurations of W, W/WO{sub 3−x}, WO{sub 3}/W/WO{sub 3−x}. • Synthesis of WO{sub 3−x} films with atomic oxygen-to-tungsten ratios between 0.3 and 3.

  8. An H-infinity approach to optimal control of oxygen and carbon dioxide contents in blood

    Science.gov (United States)

    Rigatos, Gerasimos; Siano, Pierluigi; Selisteanu, Dan; Precup, Radu

    2016-12-01

    Nonlinear H-infinity control is proposed for the regulation of the levels of oxygen and carbon dioxide in the blood of patients undergoing heart surgery and extracorporeal blood circulation. The levels of blood gases are administered through a membrane oxygenator and the control inputs are the externally supplied oxygen, the aggregate gas supply (oxygen plus nitrogen), and the blood flow which is regulated by a blood pump. The proposed control method is based on linearization of the oxygenator's dynamical model through Taylor series expansion and the computation of Jacobian matrices. The local linearization points are defined by the present value of the oxygenator's state vector and the last value of the control input that was exerted on this system. The modelling errors due to linearization are considered as disturbances which are compensated by the robustness of the control loop. Next, for the linearized model of the oxygenator an H-infinity control input is computed at each iteration of the control algorithm through the solution of an algebraic Riccati equation. With the use of Lyapunov stability analysis it is demonstrated that the control scheme satisfies the H-infinity tracking performance criterion, which signifies improved robustness against modelling uncertainty and external disturbances. Moreover, under moderate conditions the asymptotic stability of the control loop is also proven.

  9. Effect of doping content of Pr ions on oxygen vacancies in SrTiO{sub 3} films

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaofei, E-mail: xfw628@haust.edu.cn; Zhang, Chao; Zang, Guozhong; Lv, Shijie; Li, Liben

    2015-07-15

    Highlights: • Fabrication of Sr{sub 1−x}Pr{sub x}TiO{sub 3} films (x = 0–0.075) by MOD method. • The oscillating variation of OVs was shown with increasing Pr content. • The variable valence and doping position of Pr ions are key factor by XPS analysis. - Abstract: Both undoped and Pr-doped STO films are fabricated on (1 1 1) Pt/Ti/SiO{sub 2}/Si by metal organic deposition. The influence of Pr dopant on oxygen vacancies is studied using X-ray photoelectron spectroscopy and X-ray diffraction. It is found that the concentration of oxygen vacancies is not decreases with the increase of the content of higher valence Pr ions, but decreases and increases alternatively. These results are associated with the variable valence and doping position of Pr ions, and the possible causes of which are discussed.

  10. The Metabolic Changes of the Mixed Fruit Flavor Meal in the Arterio-venous Difference of Dairy Cow Mammary Gland

    Institute of Scientific and Technical Information of China (English)

    MA Yan-fen; WANG Li-fang; GAO Min; LU De-xun

    2011-01-01

    Introduction Milk favored by consumers because milk contain a large number of nutrients,such as protein,amino acids,fat,lactose,a variety of vitamins,immune activity factors,essential minerals and so on,and the proportion of the nutrients is very reasonable and those nutrients are easy to digest and absorb.So,milk is nearly a perfect food.

  11. Spinal dural arterio-venous fistula: Clinico-radiological profile and outcome following surgical occlusion in an Indian neurosurgical center

    Directory of Open Access Journals (Sweden)

    Sivashanmugam Dhandapani

    2013-01-01

    Full Text Available Background: Spinal dural arteriovenous fistula (SDAVF is a common type of spinal vascular lesion. However, there has not been any published study on its clinico-radiological characteristics or surgical outcome from India. Aim: The aim of this study was to determine the clinico-radiological features of patients with SDAVF, outcomes following surgical ligation of the fistula and the various factors involved. Materials and Methods: Patients who were operated for SDAVF were studied for demographic details, symptoms, clinical severity, radiological features and neurological outcome in the form of improvement in gait disability grades. Appropriate statistical tests were performed. Results: There were 22 (19 males, 3 females patients of SDAVF who underwent surgical ligation with a mean age of 55 years. The mean duration of symptoms at presentation was 15 months. Three patients had acute onset while the rest had insidious onset of symptoms. Out of the 22 patients, 11 (50% had motor weakness as the first symptom, 13 (59% were bedridden and 19 (86.4% had bladder involvement at presentation. Thirteen patients had fistulae in thoracic spine, whereas eight had fistulae in the lumbar spine. All had a favorable outcome in the form of at least non-progression of gait disability (14 had improvement while 8 had stabilized. The improvement was non-significantly associated with younger age, acute onset, ambulant status and fistula below T9. It was inversely associated with pain as the first symptom and fluctuant clinical course. Conclusion: Surgical occlusion of SDAVF is usually associated with either improvement or stabilization of motor weakness.

  12. The oxygen content of the high-temperature superconducting compound Bi{sub 2+x}Sr{sub 3-y}CayCu{sub 2}O{sub 8+d} with respect to varying Ca and Bi contents

    Energy Technology Data Exchange (ETDEWEB)

    Majewski, P.; Su, H.L.; Aldinger, F. [Max-Planck-Institut fuer Metallforschung, Stuggart (Germany)

    1994-12-31

    The oxygen content of Bi{sub 2+x}Sr{sub 3-y}Ca{sub y}Cu{sub 2}O{sub 8+d} (2212 phase) has been determined as a function of its cation concentration. With increasing Ca and Bi content the oxygen content increases and T{sub c} decreases. The oxygen content of Ca rich 2212 phase increases with decreasing annealing temperatures. The study shows that the T{sub c} of the 2212 phase primarily is controlled by its cation concentration.

  13. Anthropogenic processing of dust affects the oxygen content of the North Pacific Ocean

    Science.gov (United States)

    Nenes, Athanasios; Ito, Taka; Johnson, Matthew; Meskhidze, Nicholas; Valett, Jackie; Deutsch, Curtis

    2015-04-01

    Observations from the last several decades show a significant expansion of the tropical Pacific oxygen minimum zone (OMZ). However, the underlying causes remain elusive, as the currently accepted effects of ocean warming and associated solubility decease cannot fully explain the observed oxygen trend. Here we show that anthropogenic pollution can change the pattern of biological productivity and oxygen trends consistent with observations in the tropics and extratropics. These effects are caused by the mobilization of iron in mineral dust by pollutants, where it is transported and deposited to the HNLC regions of the tropical pacific affecting primary productivity and oxygen consumption by bacterial respiration. In this study, it is shown that pollution-mobilized iron deposited to high latitude oceanic environments can profoundly impact subsurface oxygen and the extent of the OMZ through long-range oceanic transport. Together with the intensification of tropical upwelling since the 1990s associated with natural climate variability, our results can explain the expansion of the OMZ in the tropical Pacific in the late twentieth century. Unlike climate variability, however, anthropogenic pollution likely influences the long-term trends in marine biogeochemistry and further alters regional productivity and subsurface oxygen distributions with profound implications for marine habitats and nitrate inventory of the oceans.

  14. Impact of the temporal variation of oxygen contents in the water column on the biogeochemistry of the benthic zone

    Science.gov (United States)

    Rigaud, Sylvain; Deflandre, Bruno; Grenz, Christian; Pozzato, Lara; Cesbron, Florian; Meulé, Samuel; Bonin, Patricia; Michotey, Valérie; Mirleau, Pascal; Mirleau, Fatma; Knoery, Joel; Zuberer, Frédéric; Guillemain, Dorian; Marguerite, Sébatien; Mayot, Nicolas; Faure, Vincent; Grisel, Raphael; Radakovitch, Olivier

    2017-04-01

    The desoxygenation of the water column in coastal areas, refered as coastal hypoxia, is currently a growing phenomenon still particularly complex to predict. This is mainly due to the fact that the biogeochemical response of the benthic ecosystem to the variation of the oxygen contents in the water column remains poorly understood. Dissolved oxygen concentration is a key parameter controling the benthic micro- and macro-community as well as the biogeochemical reactions occuring in the surface sediment. More particularly, the variation over variable time scales (from hour to years) of the oxygen deficit may induce different pathways for biogeochemical processes such as the oxydation of freshly deposited organic matter and nutrients and metals recycling. This results in variable chemical fluxes at the sediment-water interface, that may in turn, support the eutrophication and desoxygenation of the aquatic system. Our study focus on the Berre lagoon, an eutrophicated mediterranean lagoon impacted by hypoxia events in the water column. Three stations, closely located but impacted by contrasted temporal variation of oxygen deficit in the water column were selected: one station with rare oxygen deficit and with functionnal macrofauna community, one station with almost permanent oxygen deficit and no macrofauna community and one intermediate station with seasonnal oxygen deficit and degraded macrofauna community. Each station was surveyed once during a same field survey while the intermediate station was surveyed seasonnaly. For each campaign, we report vertical profiles of the main chemical components (oxygen, nutrients, metals) along the water-column/sediment continuum, with an increased vertical resolution in the benthic zone using a multi-tool approach (high vertical resolution suprabenthic water sampler and microsensors profiler). In addition, total chemical fluxes at the sediment-water interface was obtained using benthic chambers. This dataset was used to evaluate

  15. Oxygen content of YBaCuO thin films during growth by pulsed laser deposition

    NARCIS (Netherlands)

    Garcia lopez, F.J.; Garcia lopez, J.J.; Blank, David H.A.; Rogalla, Horst

    1998-01-01

    The oxidation ability of the laser plasma plume during in situ formation of YBa2Cu3O6+x (YBaCuO) thin films has been studied as a function of the deposition conditions. A quenching technique has been used immediately after termination of growth to avoid any oxygen in or out-diffusion during the

  16. Lambda based control[Oxygen content of flue gases]; Lambdabaserad reglering

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Mikael [Vattenfall Utveckling AB, Aelvkarleby (Sweden)

    2003-08-01

    A lambda sensor is useful to measure oxygen concentration in a gas. Unlike certain other methods to measure oxygen concentration, the lambda sensor is quite cheap. This makes it interesting to use in smaller heating plants for measuring oxygen concentration in flue gases because that gives a hint of in how optimised conditions the plant is running. The goal with this project has been to explore the possibilities to obtain useful data from a lambda sensor when installed in the simplest way in the exhaust flow of a plant and, if so, used this information as feedback to control the combustion process along with a simple algorithm for automatic control. The report contains two main parts, one that describes the work to getting useful data from lambda sensors and one part that describes the work to use the information from the lambda sensors as feedback and control the heat plant. The conclusion from the project is that lambda sensors could be used to obtain useful information about the combustion process and that it is possible to control the burning process so that the flue gases will contain a desired oxygen concentration by using the lambda sensor data.

  17. Oxygen consumption by oak chips in a model wine solution; Influence of the botanical origin, toast level and ellagitannin content.

    Science.gov (United States)

    Navarro, María; Kontoudakis, Nikolaos; Giordanengo, Thomas; Gómez-Alonso, Sergio; García-Romero, Esteban; Fort, Francesca; Canals, Joan Miquel; Hermosín-Gutíerrez, Isidro; Zamora, Fernando

    2016-05-15

    The botanical origin, toast level and ellagitannin content of oak chips in a model wine solution have been studied in terms of their influence on oxygen consumption. French oak chips released significantly higher amounts of ellagitannins than American oak chips at any toast level. The release of ellagitannins by oak chips decreased as the toast level increased in the French oak but this trend was not so clear in American oak. Oxygen consumption rate was clearly related to the level of released ellagitannins. Therefore, oak chips should be chosen for their potential to release ellagitannins release should be considered, not only because they can have a direct impact on the flavor and body of the wine, but also because they can protect against oxidation.

  18. Renal oxygen content is increased in healthy subjects after angiotensin-converting enzyme inhibition

    Directory of Open Access Journals (Sweden)

    Anna Stein

    2012-07-01

    Full Text Available OBJECTIVE: The association between renal hypoxia and the development of renal injury is well established. However, no adequate method currently exists to non-invasively measure functional changes in renal oxygenation in normal and injured patients. METHOD: R2* quantification was performed using renal blood oxygen level-dependent properties. Five healthy normotensive women (50±5.3 years underwent magnetic resonance imaging in a 1.5T Signa Excite HDx scanner (GE Healthcare, Waukesha, WI. A multiple fast gradient-echo sequence was used to acquire R2*/T2* images (sixteen echoes from 2.1 ms/slice to 49.6 ms/slice in a single breath hold per location. The images were post-processed to generate R2* maps for quantification. Data were recorded before and at 30 minutes after the oral administration of an angiotensin II-converting enzyme inhibitor (captopril, 25 mg. The results were compared using an ANOVA for repeated measurements (mean + standard deviation followed by the Tukey test. ClinicalTrials.gov: NCT01545479. RESULTS: A significant difference (p<0.001 in renal oxygenation (R2* was observed in the cortex and medulla before and after captopril administration: right kidney, cortex = 11.08 ± 0.56ms, medulla = 17.21 ± 1.47ms and cortex = 10.30 ± 0.44ms, medulla = 16.06 ± 1.74ms, respectively; and left kidney, cortex= 11.79 ± 1.85ms, medulla = 17.03 ± 0.88ms and cortex = 10.89 ± 0.91ms, medulla = 16.43 ± 1.49ms, respectively. CONCLUSIONS: This result suggests that the technique efficiently measured alterations in renal blood oxygenation after angiotensin II-converting enzyme inhibition and that it may provide a new strategy for identifying the early stages of renal disease and perhaps new therapeutic targets.

  19. [Effects of NaCl stress on free polyamines content and reactive oxygen species level in pumpkin roots].

    Science.gov (United States)

    Zhou, Jun-Guo; Hu, Hui-Ling; Zhu, Yue-Lin; Zhang, Gu-Wen; Liu, Zheng-Lu

    2008-09-01

    Taking Cucurbita moschata Duch hybrid 360-3 x 112-2 and C. ficifolia Bouche as test materials, the effects of NaCl stress on their plant growth and the O2*- production rate and H2O2 and free polyamines (PAs) contents in their roots were studied with hydroponic culture. The results showed that after 10 d NaCl stress, the plant growth of the two pumpkin varieties was strongly inhibited, compared with the control, and C. ficifolia was more injured than hybrid 360-3 x 112-2. Under NaCl stress, the root O2*- production rate and H2O2 content of the two pumpkin varieties were increased, but their absolute values were lower in hybrid 360-3 x 112-2 than in C. ficifolia. The contents of PAs, putrescine (Put), spermidine (Spd) and spermine (Spm) and Put/PAs ratio in the roots of the two pumpkin varieties were always higher than the control and had a trend of increased first and decreased then; while the (Spd + Spm)/Put ratio was lower than the control and decreased first and increased then. Compared with C. ficifolia Bouche, hybrid 360-3 x 112-2 always had a lower Put/PAs ratio and a lower Put content in its roots, but the (Spd + Spm)/Put ratio and Spd and Spm contents were always higher. It was concluded that under NaCl stress, the increasing PAs content in the roots of test materials played an active role in decreasing or scavenging reactive oxygen species (ROS). The conversion of Put to Spd and Spm was advantageous to the increase of plant salt tolerance. The higher salt tolerance of hybrid 360-3 x 112-2 was closely related to the lower Put/PAs ratio and the higher (Spd + Spm)/Put ratio and PAs content in its roots, and thus, the stronger capacity to scavenge ROS.

  20. Influence of iron doping on tetravalent nickel content in catalytic oxygen evolving films

    Energy Technology Data Exchange (ETDEWEB)

    Li, Nancy; Bediako, D. Kwabena; Hadt, Ryan G.; Hayes, Dugan; Kempa, Thomas J.; von Cube, Felix; Bell, David C.; Chen, Lin X.; Nocera, Daniel G.

    2017-01-30

    Iron doping of nickel oxide films results in enhanced activity for promoting the oxygen evolution reaction (OER). Whereas this enhanced activity has been ascribed to a unique iron site within the nickel oxide matrix, we show here that Fe doping influences the Ni valency. The percent of Fe3+ doping promotes the formation of formal Ni4+, which in turn directly correlates with an enhanced activity of the catalyst in promoting OER. The role of Fe3+ is consistent with its behavior as a superior Lewis acid.

  1. Standard Test Method for Oxygen Content Using a 14-MeV Neutron Activation and Direct-Counting Technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the measurement of oxygen concentration in almost any matrix by using a 14-MeV neutron activation and direct-counting technique. Essentially, the same system may be used to determine oxygen concentrations ranging from over 50 % to about 10 g/g, or less, depending on the sample size and available 14-MeV neutron fluence rates. Note 1 - The range of analysis may be extended by using higher neutron fluence rates, larger samples, and higher counting efficiency detectors. 1.2 This test method may be used on either solid or liquid samples, provided that they can be made to conform in size, shape, and macroscopic density during irradiation and counting to a standard sample of known oxygen content. Several variants of this method have been described in the technical literature. A monograph is available which provides a comprehensive description of the principles of activation analysis using a neutron generator (1). 1.3 The values stated in either SI or inch-pound units are to be regarded...

  2. Bilirubin activates transcription of HIF-1α in human proximal tubular cells cultured in the physiologic oxygen content.

    Science.gov (United States)

    Kim, Sung Gyun; Ahn, Shin-Young; Lee, Eun Seong; Kim, Sejoong; Na, Ki Young; Chae, Dong-Wan; Chin, Ho Jun

    2014-09-01

    The expression of hypoxia-inducible factor (HIF) is influenced by reactive oxygen species (ROS). Effect of bilirubin on HIF-1 expression in proximal tubular cells was investigated under physiological oxygen concentration, which is relative hypoxic condition mimicking oxygen content in the medulla of renal tissue. The human kidney (HK2) cells were cultured in 5% oxygen with or without bilirubin. HIF-1α protein expression was increased by bilirubin treatment at 0.01-0.2 mg/dL concentration. The messenger RNA expression of HIF-1α was increased by 1.69±0.05 folds in the cells cultured with 0.1 mg/dL bilirubin, compared to the control cells. The inhibitors of PI3K/mTOR, PI3K/AKT, and ERK 1/2 pathways did not attenuate increased HIF-1α expression by bilirubin. HIF-1α expression decreased by 10 µM exogenous hydrogen peroxide (H2O2); scavenger of ROS with or without bilirubin in the HK2 cells increased HIF-1α concentration more than that in the cells without bilirubin. Exogenous H2O2 decreased the phosphorylation of P70S6 kinase, which was completely reversed by bilirubin treatment. Knockdown of NOX4 gene by small interfering RNA (siRNA) increased HIF-1α mRNA expression. In coonclusion, bilirubin enhances HIF-1α transcription as well as the up-regulation of HIF-1α protein translation through the attenuation of ROS and subunits of NADPH oxidase.

  3. Supercritical CO2 Extraction of Lavandula angustifolia Mill. Flowers: Optimisation of Oxygenated Monoterpenes, Coumarin and Herniarin Content.

    Science.gov (United States)

    Jerković, Igor; Molnar, Maja; Vidović, Senka; Vladić, Jelena; Jokić, Stela

    2017-07-14

    Lavandula angustifolia is good source of oxygenated monoterpenes containing coumarins as well, which are all soluble in supercritical CO2 (SC-CO2 ). The study objective is to investigate SC-CO2 extraction parameters on: the total yield; GC-MS profile of the extracts; relative content of oxygenated monoterpenes; the amount of coumarin and herniarin; and to determine optimal SC-CO2 extraction conditions by response surface methodology (RSM). SC-CO2 extraction was performed under different pressure, temperature and CO2 flow rate determined by Box-Behnken design (BBD). The sample mass and the extraction time were kept constant. The chemical profiles and relative content of oxygenated monoterpenes (as coumarin equivalents, CE) were determined by GC-MS. Coumarin and herniarin concentrations were dosed by HPLC. SC-CO2 extracts contained linalool (57.4-217.9 mg CE/100 g), camphor (10.6-154.4 mg CE/100 g), borneol (6.2-99.9 mg CE/100 g), 1,8-cineole (5.0-70.4 mg CE/100 g), linalyl acetate (86.1-267.9 mg CE/100 g), coumarin (0.95-18.16 mg/100 g), and herniarin (0.95-13.63 mg/100 g). The interaction between the pressure and CO2 flow rate as well as between the temperature and CO2 flow rate showed statistically significant influence on the extraction yield. Applying BBD, the optimum extraction conditions for higher monoterpenes and lower coumarin content were at 10 MPa, 41°C and CO2 flow rate 2.3 kg/h, and at 30 MPa, 50°C and CO2 flow rate 3 kg/h for higher monoterpenes and coumarin content. SC-CO2 extraction is a viable technique for obtaining lavender extracts with desirable flavour components. The second-order model based on BBD predicts the results for SC-CO2 extraction quite satisfactorily. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. The Effect of Reaction Temperature on Retaining Oxirane Oxygen Contents in the Synthesis of Epoxidized Diethanolamides

    Directory of Open Access Journals (Sweden)

    C. S. Lee

    2009-01-01

    Full Text Available Epoxidized diethanolamides were synthesized by reacting diethanolamine (DEA with mixture of Epoxidized Palm Olein (EPOo ,40% w/w and Refined Bleached Deodorized Palm Kernel Olein (RBDPKOo , 60% w/w at 1:3 molar at 80°C for 5 h and continued at 110°C for another 4 h of reaction time. Synthesized diethanolamides with high content of epoxides were reacted with isocyanate in the presence of AlCl3-THF complex catalyst to produce oxazolidone linkages in polyurethane network. The rigid polyurethane foam produced is of better quality as compared to the commercially available foam.

  5. Effect of dissolved oxygen content on stress corrosion cracking of a cold worked 316L stainless steel in simulated pressurized water reactor primary water environment

    Science.gov (United States)

    Zhang, Litao; Wang, Jianqiu

    2014-03-01

    Stress corrosion crack growth tests of a cold worked nuclear grade 316L stainless steel were conducted in simulated pressurized water reactor (PWR) primary water environment containing various dissolved oxygen (DO) contents but no dissolved hydrogen. The crack growth rate (CGR) increased with increasing DO content in the simulated PWR primary water. The fracture surface exhibited typical intergranular stress corrosion cracking (IGSCC) characteristics.

  6. Linear relation between time constant of oxygen uptake kinetics, total creatine, and mitochondrial content in vitro.

    Science.gov (United States)

    Glancy, Brian; Barstow, Thomas; Willis, Wayne T

    2008-01-01

    Following the onset of moderate aerobic exercise, the rate of oxygen consumption (J(o)) rises monoexponentially toward the new steady state with a time constant (tau) in the vicinity of 30 s. The mechanisms underlying this delay have been studied over several decades. Meyer's electrical analog model proposed the concept that the tau is given by tau = R(m) x C, where R(m) is mitochondrial resistance to energy transfer, and C is metabolic capacitance, determined primarily by the cellular total creatine pool (TCr = phosphocreatine + creatine). The purpose of this study was to evaluate in vitro the J(o) kinetics of isolated rat skeletal muscle mitochondria at various levels of TCr and mitochondrial protein. Mitochondria were incubated in a medium containing 5.0 mM ATP, TCr pools of 0-1.5 mM, excess creatine kinase, and an ATP-splitting system of glucose + hexokinase (HK). Pyruvate and malate (1 mM each) were present as oxidative substrates. J(o) was measured across time after HK was added to elicit one of two levels of J(o) (40 and 60% of state 3). At TCr levels (in mM) of 0.1, 0.2, 0.3, 0.75, and 1.5, the corresponding tau values (s, means +/- SE) were 22.2 +/- 3.0, 36.3 +/- 2.2, 65.7 +/- 4.3, 168.1 +/- 22.2, and 287.3 +/- 25.9. Thus tau increased linearly with TCr (R(2) = 0.916). Furthermore, the experimentally observed tau varied linearly and inversely with the mitochondrial protein added. These in vitro results consistently conform to the predictions of Meyer's electrical analog model.

  7. Regulation of responsiveness of phosphorescence toward dissolved oxygen concentration by modulating polymer contents in organic-inorganic hybrid materials.

    Science.gov (United States)

    Okada, Hiroshi; Tanaka, Kazuo; Chujo, Yoshiki

    2014-06-15

    Platinum(II) octaethylporphyrin (PtOEP)-loaded organic-inorganic hybrids were obtained via the microwave-assisted sol-gel condensation with methyltrimethoxysilane and poly(vinylpyrrolidone). From transparent and homogeneous hybrid films, the strong phosphorescence from PtOEP was observed. Next, the resulting hybrids were immersed in the aqueous buffer, and the emission intensity was monitored by changing the dissolved oxygen level in the buffer. When the hybrid with relatively-higher amount of the silica element, the strong phosphorescence was observed even under the aerobic conditions. In contrast, the emission from the hybrids with lower amounts of the silica element was quenched under the hypoxic conditions. This is, to the best of our knowledge, the first example to demonstrate that the responsiveness of the phosphorescence intensity of PtOEP in hybrid films to the dissolved oxygen concentration in water can be modulated by changing the percentage of the contents in the material. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Low Pt-content ternary PdCuPt nanodendrites: an efficient electrocatalyst for oxygen reduction reaction

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Shaofang; Zhu, Chengzhou; Song, Junhua; Zhang, Peina; Engelhard, Mark H.; Xia, Haibing; Du, Dan; Lin, Yuehe

    2017-01-01

    Dendritic nanostructures are capturing increasing attentions in electrocatalysis owing to their unique structural features and low density. Herein, we report for the first time bromide ions mediated synthesis of low-Pt-content PdCuPt ternary nanodendrites via galvanic replacement reaction between Pt precursor and PdCu template in aqueous solution. The experimental results show that the ternary PdCuPt nanodendrites present enhanced electrocatalytic performance for oxygen reduction reaction in acid solution compared with commercial Pt/C as well as some state-of-the-art catalysts. In details, the mass activity of the PdCuPt catalyst with optimized composition is 1.73 A/mgPt at 0.85 V vs RHE, which is 14 times higher than that of commercial Pt/C catalyst. Moreover, the long-term stability test demonstrates its better durability in acid solution. After 5k cycles, there is still 70% electrochemical surface area maintained. This method provides an efficient way to synthesize trimetallic alloys with controllable composition and specific structure for oxygen reduction reaction.

  9. Aqueous singlet oxygen reaction kinetics of furfuryl alcohol: effect of temperature, pH, and salt content.

    Science.gov (United States)

    Appiani, Elena; Ossola, Rachele; Latch, Douglas E; Erickson, Paul R; McNeill, Kristopher

    2017-02-28

    The rate constant for the reaction between furfuryl alcohol (FFA) and singlet oxygen ((1)O2) in aqueous solution was measured as a function of temperature, pH and salt content employing both steady-state photolysis (β value determination) and time-resolved singlet oxygen phosphorescence methods. The latter provided more precise and reproducible data. The reaction rate constant, krxn,FFA, had a relatively small temperature dependence, no pH dependence and showed a small increase in the presence of high salt concentrations (+19% with 1 M NaCl). A critical review of the available literature suggested that the widely used value of 1.2 × 10(8) M(-1) s(-1) is likely overestimated. Therefore, we recommend the use of 1.00 × 10(8) M(-1) s(-1) for reactions performed in low ionic strength aqueous solutions (freshwater) at 22 °C. Furthermore, corrections are provided that should be applied when working at higher or lower temperatures, and/or at high salt concentrations (seawater).

  10. Cloud Information Content Analysis for EPIC's Oxygen A- and B-band Channels

    Science.gov (United States)

    Davis, A. B.; Sanghavi, S.

    2011-12-01

    The Earth Polychromatic Imaging Camera (EPIC) instrument on the Deep Space Climate Observatory (DSCOVR) will have two molecular oxygen channels: one for the well-known ``A'' band at~764 nm and one for the weaker ``B'' band at 688~nm. In both cases, a channel-integrated relative measurement of absorption is possible using an ``in-band'' channel and a nearby ``reference'' channel. Together, these four observations enable a rudimentary differential optical absorption spectroscopy (DOAS) of O2 in the characteristic retro-reflection geometry of the L1 vantage point. A priori, we thus have at best two new pieces of cloud information to access. EPIC's pixels have 10x10 km2 footprints at nadir (center of the illuminated disk), more as the viewing angle increases away from local zenith. What new information can be learned about clouds from these data on a pixel-by-pixel basis? O2 A-band observations from space have been pioneered with CNES's POLDER, ESA's SCIAMACHY, and JAXA's GOSat. NASA's OCO-2, to be launched in early 2013, will also have A-band capability. POLDER has low spectral and spatial resolutions, but offers multiple viewing directions for every pixel; SCIAMACHY has higher spectral but worse spatial resolution and just one viewing angle. GOSat has very high spectral but rather low spatial resolutions, again with the possibility of dense angular sampling, but no imaging (just one pixel at a time). OCO-2, a narrow swath imager, will have similarly high spectral resolution and reasonably high ( ˜2~km) spatial resolution. Of these four LEO missions, two are focused on CO2 DOAS, with O2 being assayed operationally only to deliver it in ppm's. POLDER and SCIAMACHY however have official cloud products based on A-band measurements. They contain, at the least, an estimate of cloud top height and, at the most, that plus an estimate of cloud pressure thickness. Cloud optical depth and effective particle size are derived from other spectral data, including continuum values

  11. Content

    DEFF Research Database (Denmark)

    Keiding, Tina Bering

    Aim, content and methods are fundamental categories of both theoretical and practical general didactics. A quick glance in recent pedagogical literature on higher education, however, reveals a strong preoccupation with methods, i.e. how teaching should be organized socially (Biggs & Tang, 2007......; Race, 2001; Ramsden, 2003). This trend appears closely related to the ‘from-teaching-to-learning’ movement, which has had a strong influence on pedagogy since the early nineties (Keiding, 2007; Terhart, 2003). Another interpretation of the current interest in methodology can be derived from...... for selection of content (Klafki, 1985, 2000; Myhre, 1961; Nielsen, 2006). These attempts all share one feature, which is that criteria for selection of content appear very general and often, more or less explicitly, deal with teaching at the first Bologna-cycle; i.e. schooling at the primary and lower...

  12. Ultrasonic evaluation of oxygen content, modulus, and microstructure changes in YBa2Cu3O(7-x) occurring during oxidation and reduction

    Science.gov (United States)

    Roth, Don J.; Deguire, Mark R.; Dolhert, Leonard E.

    1992-01-01

    Ultrasonic velocity measurement techniques were used to evaluate the effects of oxidation and reduction on the elastic properties, global microstructure and oxygen content of the YBa2Cu3O(7-x) ceramic superconductor for samples ranging from 70 to 90 pct of theoretical density. Bulk density, velocity, and elastic modulus generally increased with increasing oxygen content upon oxidation, and this behavior was reversible. Velocity image patterns were similar after oxidation and reduction treatments for a 90 pct. dense sample, although the velocity value at any given point on the sample was changed following the treatments. The unchanging pattern correlated with destructive measurements showing that the spatial pore distribution (fraction and size) was not measurably altered after the treatments. Changes in superconducting behavior, crystal structure, and grain structure were observed consistent with changes in oxygen content.

  13. Solid phase epitaxy of EuTiO3 thin films on SrTiO3 (100) substrates with different oxygen contents

    Science.gov (United States)

    Shimamoto, K.; Hirose, Y.; Nakao, S.; Fukumura, T.; Hasegawa, T.

    2013-09-01

    We investigated solid phase epitaxy (SPE) of EuTiO3 thin films on SrTiO3 (100) substrates with different oxygen contents. Amorphous EuTiOx thin films were deposited onto SrTiO3 substrates by pulsed laser deposition and crystallized by subsequent annealing in a vacuum chamber. A pure perovskite EuTiO3 phase was obtained on the reduced (i.e., oxygen-depleted SrTiO3) substrate, while an Eu2Ti2O7 phase was obtained on the oxygen-rich one. These results suggest that oxygen migration occurs between the EuTiOx film and SrTiO3 during SPE. The electric properties of the fabricated EuTiO3 thin films also depended on the amount of oxygen vacancies in the SrTiO3 substrate.

  14. Pilot study to visualise and measure skin tissue oxygenation, erythema, total haemoglobin and melanin content using index maps in healthy controls

    Science.gov (United States)

    Poxon, Ian; Wilkinson, Jack; Herrick, Ariane; Dickinson, Mark; Murray, Andrea

    2014-02-01

    We report on a method for analysing multispectral images of skin in vivo for the measurement and visualisation of skin characteristics. Four different indices were used to characterise skin tissue oxygenation, erythema, total haemoglobin and melanin content. Index values were calculated pixel-wise and combined to create index maps to visualise skin properties. Quantitative measurement of tissue oxygenation saturation was possible by calibrating the oxygenation index using a commercial, calibrated oximeter. Index maps were tested by arterial occlusion of the index finger with multispectral images taken before, during and after occlusion in a pilot study with 10 healthy controls.

  15. Oxygen-Content-Controllable Graphene Oxide from Electron-Beam-Irradiated Graphite: Synthesis, Characterization, and Removal of Aqueous Lead [Pb(II)].

    Science.gov (United States)

    Bai, Jing; Sun, Huimin; Yin, Xiaojie; Yin, Xianqiang; Wang, Shengsen; Creamer, Anne Elise; Xu, Lijun; Qin, Zhi; He, Feng; Gao, Bin

    2016-09-28

    A high-energy electron beam was applied to irradiate graphite for the preparation of graphene oxide (GO) with a controllable oxygen content. The obtained GO sheets were analyzed with various characterization tools. The results revealed that the oxygen-containing groups of GO increased with increasing irradiation dosages. Hence, oxygen-content-controllable synthesis of GO can be realized by changing the irradiation dosages. The GO sheets with different irradiation dosages were then used to adsorb aqueous Pb(II). The effects of contact time, pH, initial lead ion concentration, and ionic strength on Pb(II) sorption onto different GO sheets were examined. The sorption process was found to be very fast (completed within 20 min) at pH 5.0. Except ionic strength, which showed no/little effect on lead sorption, the other factors affected the sorption of aqueous Pb(II) onto GO. The maximum Pb(II) sorption capacities of GO increased with irradiation dosages, confirming that electron-beam irradiation was an effective way to increase the oxygen content of GO. These results suggested that irradiated GO with a controllable oxygen content is a promising nanomaterial for environmental cleanup, particularly for the treatment of cationic metal ions, such as Pb(II).

  16. Interaction of phosphatidylcholine and α-tocopherol on the oxidation of sunflower oil and content changes of phosphatidylcholine and tocopherol in the emulsion under singlet oxygen.

    Science.gov (United States)

    Lee, Yoosung; Choe, Eunok

    2011-04-01

    Interaction of phosphatidylcholine (PC) and α-tocopherol (α-Toc) on the oxidation of oil in the emulsion consisting of sunflower oil and water under singlet oxygen at 25 °C was studied by determining peroxide value (PV) and conjugated dienoic acid (CDA) contents. Singlet oxygen was produced by chlorophyll b under 1700 lux. Single addition of PC or α-Toc decreased the values of peroxides and CDAs of oil in the emulsion via singlet oxygen quenching. PC and α-Toc showed simply additive interaction in decreasing the singlet oxygen oxidation of oil in the emulsion. α-Toc was a physical quencher of singlet oxygen in the emulsion, but PC involved chemical quenching in the antioxidant action. Chlorophyll and PC contents were decreased in the emulsion under singlet oxygen, while α-Toc was not. α-Toc protected chlorophyll and PC from degradation, and was a more important component than PC in the oil oxidation under singlet oxygen in the emulsion.

  17. PENGARUH MINUMAN BEROKSIGEN TERHADAP SISTEM IMUN, KADAR MALONALDEHIDA DAN PERFORMA RESPONDEN MAHASISWA OLAHRAGAWAN [Effect of Oxygenated Water on Immune System, Malonaldehyde Content and Student-Athlete Performance

    Directory of Open Access Journals (Sweden)

    Cesar Welya Refdi

    2014-06-01

    Full Text Available Exercise requires more oxygen input and cannot be fully obtained through breathing. The body has a homeostatic system, when more ATP is needed, the more oxygen is required by the body. Limited supply of oxygen such as those happens in athlete’s body automatically switches the respiration from aerobic into anaerobic. This situation results in building up of lactic acid which in turn lowers the energy for cellular metabolism as well asenergy for exercise. The purpose of this study was to assess the effects of short-term and long-term drinking of oxygenated water on lactic acid and energy expenditure (EE in exercise performance; Cluster of Differentiation-4 (CD4, CD8, CD56, Interleukin-6 (IL-6 contents; and level of malonaldehyde. During short-term intervention, 12 male student volunteers drank oxygenated (50, 80 and 130 ppm water and normal mineral water, 15 minutes before treadmill and after treadmill (10 Kmh. The lactic acid concentration was measured before and after treadmill, and 5 minutes after the reconsumption of the oxygenated water. During long-term intervention, 17 male student volunteers drank oxygenated (100 ppm water twice a day for 21 days. The blood plasma and lymphocyte sampled before and after intervention were analyzed for the same parameters. The results showed that oxygenated water had no effect on lactic acid accumulations and EE. Similarlyt he long-term study showed that oxygenated water did not affect CD4 and CD8, had no harmful effect on IL-6 and malonaldehyde, yet it significantly increased the CD56 content.

  18. Three-Dimensional Short-Term Prediction Model of Dissolved Oxygen Content Based on PSO-BPANN Algorithm Coupled with Kriging Interpolation

    Directory of Open Access Journals (Sweden)

    Yingyi Chen

    2016-01-01

    Full Text Available Dissolved oxygen (DO content is a significant aspect of water quality in aquaculture. Prediction of dissolved oxygen may timely avoid the financial loss caused by inappropriate dissolved oxygen content and three-dimensional prediction can achieve more accurate and overall guidance. Therefore, this study presents a three-dimensional short-term prediction model of dissolved oxygen in crab aquaculture ponds based on back propagation artificial neural network (BPANN optimized by particle swarm optimization (PSO, which coupled with Kriging method. In this model, wavelet analysis is adopted for denoising, BPANN optimized by PSO is utilized for data analysis and one-dimensional prediction, and Kriging method is used for three-dimensional prediction. Compared with traditional one-dimensional prediction model, three-dimensional model has more real reaction of dissolved oxygen content in crab growth environment. In particular, the merits of PSO are evaluated against genetic algorithm (GA. The root mean square error (RMSE, mean absolute error (MAE, and mean absolute percentage error (MAPE for PSO model are 0.136445, 0.90534, and 0.15384, respectively, while for the GA model the values are 2.04184, 1.18316, and 0.21014, respectively. Furthermore, results of cross validation experiment show that the average error of this model is 0.0705 (mg/L. Consequently, this study suggests that the prediction model operates in a satisfactory manner.

  19. Processing of low carbon content interstellar ice analogues by cosmic rays: implications for the chemistry around oxygen-rich stars

    Science.gov (United States)

    de Barros, A. L. F.; da Silveira, E. F.; Pilling, S.; Domaracka, A.; Rothard, H.; Boduch, P.

    2014-03-01

    Radiolysis of a homogeneous H2O:H2CO:CH3OH (100:2:0.8) ice mixture by fast heavy ions is performed in the laboratory in an attempt to simulate the interaction of cosmic rays with frozen surfaces at 15 K. Bombarded by 220-MeV 16O7 + ions, the ice layer is thin enough to be traversed by projectiles at approximately constant velocity and with charge states close to the equilibrium one. Analysis by Fourier transform infrared spectroscopy (FTIR) reveals that the molecular species formed are CH4, CO2, CO, HCO, HCOO- and CH3OCHO. The formation and dissociation cross-sections of all observed daughter molecules are determined. As a control procedure, a carbon budget is performed as the beam fluence increases. The observed radiation effects lead to a general observation that the destruction cross-sections of condensed gases by heavy ions are ruled by a power law that is a function of the electronic stopping power: σd ˜ Sn_e, where n is approximately 3/2. This relation is observed for the destruction of precursor H2CO molecules and for the formation of daughter species. The present results help our understanding of the chemical and physicochemical interactions induced by heavy cosmic rays in cold astrophysical environments with low carbon contents, such as those around oxygen-rich stars.

  20. CONTENTS

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    The Development and Evolution of the Idea of the Mandate of Heaven in the Zhou Dynasty The changes in the idea of Mandate of Heaven during the Shang and Zhou dynasties are of great significance in the course of the development of traditional Chinese culture. The quickening and awakening of the humanistic spirit was not the entire content of the Zhou idea of Mandate of Heaven. In the process of annihilating the Shang dynasty and setting up their state, the Zhou propagated the idea of the Mandate of Heaven out of practical needs. Their idea of the Mandate of Heaven was not very different from that of the Shang. From the Western Zhou on, the Zhou idea of Mandate of Heaven by no means developed in a linear way along a rational track. The intermingling of rationality and irrationality and of awakening and non-awakening remained the overall state of the Zhou intellectual superstructure after their "spiritual awakening".

  1. Neutron-scattering determination of the structural parameters versus oxygen content of YBa2Cu3O6+x single crystals

    DEFF Research Database (Denmark)

    Casalta, H.; Schleger, P.; Harris, P.

    1996-01-01

    .96 (superconducting, orthorhombic phase), In the orthorhombic phase, both twinned and detwinned samples were measured. A detailed discussion is presented of the systematic changes taking place in the atomic positions and Debye-Waller factors as the oxygen content is varied, Some qualitative highlights are that one...... can identify two distinct regions within the unit cell: the characteristics of the atoms near the CuOx basal plane are essentially driven by the effect of oxygen addition, whereas near the CuO2 bilayer, the trends are more subtle and presumably dominated by charge transfer and bond-distance effects....... Also, there is neither an abrupt change of the apical-oxygen position at the orthorhombic to tetragonal transition, nor is there any indication of depletion of the atomic sites except for the chain-site oxygen, The superconducting critical temperatures or Neel temperatures, as well as the existence...

  2. Contents

    Directory of Open Access Journals (Sweden)

    Editor IJRED

    2012-11-01

    Full Text Available International Journal of Renewable Energy Development www.ijred.com Volume 1             Number 3            October 2012                ISSN 2252- 4940   CONTENTS OF ARTICLES page Design and Economic Analysis of a Photovoltaic System: A Case Study 65-73 C.O.C. Oko , E.O. Diemuodeke, N.F. Omunakwe, and E. Nnamdi     Development of Formaldehyde Adsorption using Modified Activated Carbon – A Review 75-80 W.D.P Rengga , M. Sudibandriyo and M. Nasikin     Process Optimization for Ethyl Ester Production in Fixed Bed Reactor Using Calcium Oxide Impregnated Palm Shell Activated Carbon (CaO/PSAC 81-86 A. Buasri , B. Ksapabutr, M. Panapoy and N. Chaiyut     Wind Resource Assessment in Abadan Airport in Iran 87-97 Mojtaba Nedaei       The Energy Processing by Power Electronics and its Impact on Power Quality 99-105 J. E. Rocha and B. W. D. C. Sanchez       First Aspect of Conventional Power System Assessment for High Wind Power Plants Penetration 107-113 A. Merzic , M. Music, and M. Rascic   Experimental Study on the Production of Karanja Oil Methyl Ester and Its Effect on Diesel Engine 115-122 N. Shrivastava,  , S.N. Varma and M. Pandey  

  3. Intraorgan differences of blood flow, oxygen supply and glycogen content in the multilobular liver of normal and hemorrhagic rats.

    Science.gov (United States)

    Metzger, H P; Schywalsky, M

    1992-02-01

    In order to characterize intraorgan differences in blood supply of the rat liver, hepatic blood flow (HBF), surface oxygen tension (sPO2) and glycogen content of the largest and smallest lobi have been determined for normal and hemorrhagic rats (N = 68) in ketamin-xylazine anesthesia. 1. Mean HBF +/- SD of lobus sinister measured 1.07 +/- 0.23 ml/g min (n = 119 determinations, N = 9 rats); HBF of lob. caudatus dexter showed a left-shifted histogram (mean value = 0.77 ml/g.min, median = 0.72 ml/g.min, modul = 0.63 ml/g.min, p less than 0.005). 2. Mean sPO2 +/- SD of lob. sin. measured 23 +/- 6.8 mm Hg (n = 168, N = 16). The histograms of lob. caudat. dext. and sin. were left-shifted (mean value of l.c.d. = 9 mm Hg, median = 4 mm Hg, modul = 0 mm Hg, mean value of l.c.s. = 16 mm Hg, median = 17 mm Hg, modul = 0 mm Hg). Under hemorrhage sPO2 became almost zero in 91% of the measurements. 3. In response to an arterial bolus of fluorescence stained gamma-globulins, spreading of the dye showed a pronounced front and marked periportal area within lob. sin., while an irregular convective front and a much smaller area were detected within both of the lobi caudati. Under hemorrhage, intersinusoidal staining and undefined, irregular contours were observed within all lobes. 4. Compared with lob. sin. preferential glycogen depletion and partial centrilobular necrosis were detected within both of the lob. caudati while under hemorrhage the glycogen stores were empty and severe group necroses have been observed especially within the small lobi. From the data it is concluded that in comparison to lob. sin. an insufficient supply and pronounced vulnerability against hepatic ischemia exists within the small lobi caudati.

  4. Electrochemical Exfoliation of Graphite in Aqueous Sodium Halide Electrolytes toward Low Oxygen Content Graphene for Energy and Environmental Applications.

    Science.gov (United States)

    Munuera, J M; Paredes, J I; Enterría, M; Pagán, A; Villar-Rodil, S; Pereira, M F R; Martins, J I; Figueiredo, J L; Cenis, J L; Martínez-Alonso, A; Tascón, J M D

    2017-07-19

    Graphene and graphene-based materials have shown great promise in many technological applications, but their large-scale production and processing by simple and cost-effective means still constitute significant issues in the path of their widespread implementation. Here, we investigate a straightforward method for the preparation of a ready-to-use and low oxygen content graphene material that is based on electrochemical (anodic) delamination of graphite in aqueous medium with sodium halides as the electrolyte. Contrary to previous conflicting reports on the ability of halide anions to act as efficient exfoliating electrolytes in electrochemical graphene exfoliation, we show that proper choice of both graphite electrode (e.g., graphite foil) and sodium halide concentration readily leads to the generation of large quantities of single-/few-layer graphene nanosheets possessing a degree of oxidation (O/C ratio down to ∼0.06) lower than that typical of anodically exfoliated graphenes obtained with commonly used electrolytes. The halide anions are thought to play a role in mitigating the oxidation of the graphene lattice during exfoliation, which is also discussed and rationalized. The as-exfoliated graphene materials exhibited a three-dimensional morphology that was suitable for their practical use without the need to resort to any kind of postproduction processing. When tested as dye adsorbents, they outperformed many previously reported graphene-based materials (e.g., they adsorbed ∼920 mg g(-1) for methyl orange) and were useful sorbents for oils and nonpolar organic solvents. Supercapacitor cells assembled directly from the as-exfoliated products delivered energy and power density values (up to 15.3 Wh kg(-1) and 3220 W kg(-1), respectively) competitive with those of many other graphene-based devices but with the additional advantage of extreme simplicity of preparation.

  5. Influence of the Oxygen content on the thermal migration of Xenon in ZrC{sub x}O{sub 1−x}

    Energy Technology Data Exchange (ETDEWEB)

    Pipon, Y., E-mail: pipon@ipnl.in2p3.fr [Institut de Physique Nucléaire de Lyon - IPNL, Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR 5822, 4 rue Enrico Fermi, 69622 Villeurbanne Cedex (France); Institut Universitaire de Technologie - IUT, Université de Lyon, Université Lyon 1, 94 Bd. Niels Bohr, 69622 Villeurbanne Cedex (France); Toulhoat, N. [Institut de Physique Nucléaire de Lyon - IPNL, Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR 5822, 4 rue Enrico Fermi, 69622 Villeurbanne Cedex (France); Commissariat à l’Energie Atomique CEA/DEN, Centre de Saclay, 91191 Gif sur Yvette Cedex (France); Moncoffre, N. [Institut de Physique Nucléaire de Lyon - IPNL, Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR 5822, 4 rue Enrico Fermi, 69622 Villeurbanne Cedex (France); Gutierrez, G. [Institut d’Électronique du Solide et des Systèmes - InESS, 23, rue du Loess, BP 20 CR, 67037 Strasbourg Cedex 2 Strasbourg (France); Maître, A.; Gendre, M. [Laboratoire Science des Procédés Céramiques et Traitements de Surface, UMR CNRS 6638, Centre Européen de la Céramique, 12 rue Atlantis, 87068 Limoges Cedex (France)

    2013-09-15

    Zirconium carbide (ZrC) is a refractory ceramic presenting interesting properties such as a high melting point, a very high hardness and a good thermal stability. For these reasons, this material is considered as a candidate for fuel coating for fourth-generation reactors in particular for the Gas cooled Fast Reactors (GFR). The ceramic temperature could reach 1200 °C in normal reactor operation and reach 1700 °C in accidental conditions. It is therefore important to assess the ZrC thermal retention capacity regarding abundant and/or volatile fission products. This paper deals with the behavior of Xenon which is the major gaseous fission product created during fission. Previous studies have shown that Xenon remained motionless in an “Oxygen-poor” matrix such as ZrC{sub 0.95}O{sub 0.05}, up to temperatures of 1800 °C. However, Zirconium oxycarbides are known to be very sensitive to oxidation. This study aims therefore at studying the behavior of Xenon in Zirconium oxycarbide samples with different Oxygen contents. Xenon is introduced by ion implantation and the samples are annealed in secondary vacuum in the temperature range 1400 °C–1800 °C. The Oxygen profiles are determined by using the {sup 16}O({sup 4}He, {sup 4}He){sup 16}O nuclear reaction at 7.5 MeV and the concentration profiles of Xenon are measured by Rutherford Backscattering Spectrometry at each step of the treatment. The results show that the behavior of the material during annealing with respect to oxidation is strongly related to its initial Oxygen content. More generally, the higher the initial Oxygen content, the more important is the oxidation. Consequently, the Xenon migration is enhanced in Oxygen rich Zirconium carbides.

  6. [Volume chemistry-ultraviolet spectrum differential method for determining the oxygen content in anti-corrosion copper powder with surface film consisting of benzotriazole].

    Science.gov (United States)

    Zhang, Tai-ming; Ding, Feng; Liang, Yi-zeng

    2006-11-01

    A method for determining the oxygen content in anti-corrosion copper powder with benzotriazole inhibitor surface film was established and the ultraviolet spectra of benzotriazole under various conditions were studied. The maximum absorption was at lamdamax=273 nm, and the temperature did not influence the absorption intensity at normal temperature. The linear range of concentration was 0-2.2 microg x mL(-1), the detection limit was 0.02 microg x mL(-1), and the apparent molar absorptivity of benzotriazole was epsilon = 5.41 x 10(4) L x mol(-1) x cm(-1) at 273 nm. Because the anti-corrosion copper powder consisted of copper metal, copper oxide and benzotriazole protecting film, the Cu and BTA contents of the powder were determined through EDTA titration and ultraviolet spectrophotometry, respectively, after the samples were decomposed with HCl and H2O2, and the oxygen content of the powder was calculated by differential method. The instruments are simple, the method is economical, and the manipulation is convenient. The standard deviation is 1.7%, and the differentiation coefficient is 7.6%. In conjunction with the application of the national standard method, the oxygen contents before and after the formation of the protecting film of the electrolyte copper powder were comparatively analyzed with satisfactory results.

  7. Polarimetric remote sensing in oxygen A and B bands: sensitivity study and information content analysis for vertical profile of aerosols

    Science.gov (United States)

    Ding, Shouguo; Wang, Jun; Xu, Xiaoguang

    2016-05-01

    Theoretical analysis is conducted to reveal the information content of aerosol vertical profile in space-borne measurements of the backscattered radiance and degree of linear polarization (DOLP) in oxygen (O2) A and B bands. Assuming a quasi-Gaussian shape for aerosol vertical profile characterized by peak height H and half width γ (at half maximum), the Unified Linearized Vector Radiative Transfer Model (UNL-VRTM) is used to simulate the Stokes four-vector elements of upwelling radiation at the top of atmosphere (TOA) and their Jacobians with respect to H and γ. Calculations for different aerosol types and different combinations of H and γ values show that the wide range of gas absorption optical depth in O2 A and B band enables the sensitivity of backscattered DOLP and radiance at TOA to the aerosol layer at different altitudes. Quantitatively, DOLP in O2 A and B bands is found to be more sensitive to H and γ than radiance, especially over the bright surfaces (with large visible reflectance). In many O2 absorption wavelengths, the degree of freedom of signal (DFS) for retrieving H (or γ) generally increases with H (and γ) and can be close to unity in many cases, assuming that the composite uncertainty from surface and aerosol scattering properties as well as measurements is less than 5 %. Further analysis demonstrates that DFS needed for simultaneous retrieval of H and γ can be obtained from a combined use of DOLP measurements at ˜ 10-100 O2 A and B absorption wavelengths (or channels), depending on the specific values of H. The higher the aerosol layer, the fewer number of channels for DOLP measurements in O2 A and B bands are needed for characterizing H and γ. Future hyperspectral measurements of DOLP in O2 A and B bands are needed to continue studying their potential and their combination with radiance and DOLP in atmospheric window channels for retrieving the vertical profiles of aerosols, especially highly scattering aerosols, over land.

  8. Activated carbon immersed in water-the origin of linear correlation between enthalpy of immersion and oxygen content studied by molecular dynamics simulation.

    Science.gov (United States)

    Terzyk, Artur P; Gauden, Piotr A; Furmaniak, Sylwester; Wesołowski, Radosław P; Kowalczyk, Piotr

    2010-09-28

    First Molecular Dynamics simulation results of activated carbon immersion in water are reported. Using a Virtual Porous Carbon Model of "soft" carbon the influence of surface oxygen content, distribution of groups and micropore diameter on the enthalpy of immersion is studied. The empirical relation between enthalpy and concentration of surface groups (as well as polar surface area) is reproduced by molecular simulation results. It is shown that for strongly hydrophobic carbons immersed in water, the water-vapour interface inside pores appears. This interface vanishes with the rise in content of surface oxygen. We discuss some nuances of the interfacial region using proximal distribution functions and hydrogen bonds statistics. Finally we conclude that the mechanism of immersion process is in accordance with Pratt-Chandler theory of hydrophobic interactions.

  9. Effect of Oxygen Content Upon the Microstructural and Mechanical Properties of Type 316L Austenitic Stainless Steel Manufactured by Hot Isostatic Pressing

    Science.gov (United States)

    Cooper, Adam J.; Cooper, Norman I.; Dhers, Jean; Sherry, Andrew H.

    2016-09-01

    Although hot isostatic pressing (HIP) has been shown to demonstrate significant advances over more conventional manufacture routes, it is important to appreciate and quantify the detrimental effects of oxygen involvement during the HIP manufacture process on the microstructural and material properties of the resulting component. This paper quantifies the effects of oxygen content on the microstructure and Charpy impact properties of HIP'd austenitic stainless steel, through combination of detailed metallographic examination and mechanical testing on HIP'd Type 316L steel containing different concentrations (100 to 190 ppm) of oxygen. Micron-scale pores were visible in the microstructure of the HIP'd materials postmetallographic preparation, which result from the removal of nonmetallic oxide inclusions during metallographic preparation. The area fraction of the resulting pores is shown to correlate with the oxygen concentration which influences the Charpy impact toughness over the temperature range of 77 K to 573 K (-196 °C to 300 °C), and demonstrates the influence of oxygen involved during the HIP manufacture process on Charpy toughness. The same test procedures and microstructural analyses were performed on commercially available forged 316L. This showed comparatively fewer inclusions and exhibited higher Charpy impact toughness over the tested temperature range.

  10. Oxygen content modulation by nanoscale chemical and electrical patterning in epitaxial SrCoO3-δ (0 < δ ≤ 0.5) thin films

    Science.gov (United States)

    Hu, S.; Seidel, J.

    2016-08-01

    Fast controllable redox reactions in solid materials at room temperature are a promising strategy for enhancing the overall performance and lifetime of many energy technology materials and devices. Easy control of oxygen content is a key concept for the realisation of fast catalysis and bulk diffusion at room temperature. Here, high quality epitaxial brownmillerite SrCoO2.5 thin films have been oxidised to perovskite (P) SrCoO3 with NaClO. X-ray diffraction, scanning probe microscopy and x-ray photoelectron spectroscopy measurements were performed to investigate the structural and electronic changes of the material. The oxidised thin films were found to exhibit distinct morphological changes from an atomically flat terrace structure to forming small nanosized islands with boundaries preferentially in [100] or [010] directions all over the surface, relaxing the in-plane strain imposed by the substrate. The conductivity, or oxygen content, of each single island is confined by these textures, which can be locally patterned even further with electric poling. The high charging level at the island boundaries indicates a magnified electric capacity of SCO thin films, which could be exploited in future device geometries. This finding represents a new way of oxygen modulation with associated self-assembled charge confinement to nanoscale boundaries, offering interesting prospects in nanotechnology applications.

  11. Increasing the sensitivity of the spectrophotometric determinations of the oxygen content in YBCO superconducting samples using the I(3-)-starch compound.

    Science.gov (United States)

    Nedeltcheva, Tsvetanka K; Georgieva, Stela Iv; Vladimirova, Latinka K; Stoyanova-Ivanova, Angelina K

    2009-03-15

    The conditions for formation of the I(3)(-)-starch compound and measuring its absorbance have been found, and a spectrophotometric method has been developed for the determination of the oxygen content in YBa(2)Cu(3)O(y) superconducting bulk samples. The method involves the following stages: a decomposition of the sample in an acid medium in the presence of iodide ions under inert atmosphere; formation of a complex between Cu(II) and glycine; binding the I(3)(-)-complex with a starch and the absorbance measurement of the colored I(3)(-)-starch compound. The coefficient of the active oxygen is calculated by the ratio of the absorbances of two solutions and the method does not require both calibration and precise measuring sample mass. The accuracy of the results is confirmed applying the comparative spectrophotometric method that uses the yellow I(3)(-)-complex. The precision of the results evaluated by the relative standard deviation is 2%. The developed method is sensitive and allows a sample mass about 2mg to be used. The analysis is rapid and requires a simple and inexpensive apparatus. Thus the new method would be useful for an express analytical control of the oxygen content of YBCO-superconducting materials produced for the electronics.

  12. In Vitro Cytotoxicity of a Ti-35Nb-7Zr-5Ta Alloy Doped with Different Oxygen Contents

    Directory of Open Access Journals (Sweden)

    Tatiani Ayako Goto Donato

    2014-03-01

    Full Text Available Cp-Ti is the most common material used for dental implants, but its elastic modulus is around five times higher than that of bone. Recently, promising alloys that add Nb, Ta, Zr and Mo to Ti have been developed. The mechanical properties of these alloys are directly related to its microstructure and the presence of interstitial elements, such as oxygen, carbon, nitrogen and hydrogen. In this study, the in vitro cytotoxicity of Ti-35Nb-7Zr-5Ta (TNZT alloys was analyzed in the as-received condition and after being doped with several small quantities of oxygen on a cultured osteogenic cell. The cell’s morphology was also examined by scanning electron microscopy (SEM. The TNZT alloy presented no cytotoxic effects on osteoblastic cells in the studied conditions.

  13. Oxidation/dissolution of ferritic ODS steels in static lead with various oxygen content at 650 °C

    Energy Technology Data Exchange (ETDEWEB)

    Tsisar, Valentyn, E-mail: valentyn.tsisar@kit.edu [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Physical-Mechanical Institute of National Academy of Sciences of Ukraine (PhMI NASU), 5 Naukova St., 79060 Lviv (Ukraine); Yeliseyeva, Olga [Physical-Mechanical Institute of National Academy of Sciences of Ukraine (PhMI NASU), 5 Naukova St., 79060 Lviv (Ukraine); Konys, Jürgen [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2014-12-15

    Highlights: • Bi-layer magnetite/spinel scale grows on ferritic ODS steels in Pb with ∼10{sup −3} mass%O at 650 °C. • Single-layer Cr-based oxide film forms in Pb melt with ∼10{sup −6} mass%O. • Fine-grained structure of ODS steels favors formation of Cr-based oxide film. • In pure Pb, the fine-grained structure favors severe dissolution attack. - Abstract: The compatibility of ferritic oxide dispersion strengthened (ODS) steels with static liquid Pb at 650 °C was investigated for up to 1750 h. The dependence of corrosion behavior on oxygen concentration in the melt and steel structure was determined. The interaction mode changed from intensive oxidation in the oxygen-saturated melt (∼10{sup −3} mass%O), accompanied by the formation of a bi-layer magnetite/spinel scale, to formation of a thin Cr-based oxide film in oxygen-added melt (∼10{sup −6} mass%O) and to the severe steel dissolution in pure Pb (≤10{sup −14} mass%O). The effect of specific phase-structural state of ODS steels (presence of strengthening dispersive oxide particles, fine-grained structure, texture, residual porosity, etc.) on their corrosion response to Pb melts depending on the oxygen concentration is considered. The viability of the in situ formed Cr-based oxide film, as a promising way to improve the corrosion resistance of steels in high-temperature Pb melts (T > 550 °C) is discussed as well.

  14. Arterio-venous concentration difference of [51Cr]EDTA after a single injection in man. Significance of renal function and local blood flow

    DEFF Research Database (Denmark)

    Rehling, M; Hyldstrup, Lars; Henriksen, Jens Henrik

    1989-01-01

    introduced in the measurement of renal plasma clearance and total plasma clearance by using venous blood samples instead of arterial. In 13 patients with GFR ranging from 29 to 150 ml min-1, Ca was higher than Cv immediately after the injection. After mean 38 min (range 12-82 min) the two curves crossed......, and 180-300 min post-injection (p.i.) Cv was 5.9% higher than Ca (range 0.5-13.9%, P less than 0.001). The more reduced renal function, the smaller was the concentration difference. The areas under the arterial and the venous plasma concentration curves did not differ significantly at either 0-infinity......, whereas the difference was very sensitive to even small changes in forearm blood flow within the physiological range. For measurement of renal plasma clearance it is recommended to use one long period: from the time of injection until 300 min p.i. or longer. If the clearance period is too short, the use...

  15. [Tunnelled internal jugular vein catheters with taurolidine lock: an acceptable challenge to arterio-venous fistula in 70 years old haemodialyzed patients: a prospective pilot study].

    Science.gov (United States)

    Branger, Bernard; Reboul, Pascal; Prelipcean, Camélia; Noguera, Maria Eugenia; Cariou, Sylvain; Granolleras, Céline; Vecina, Frédérique; Zabadani, Bachir; Boubenider, Samir; Rousseau, Philippe; Deshodt, Gérard; Ramperez, Pierre; Hory, Bernard; Picard, Eric; Branchereau, Pascal; Fabbro-Peray, Pascale; Fourcade, Jacques

    2011-07-01

    Arteriovenous fistula (AVF) is still in 2010 the gold standard of vascular(2) access in haemodialysis (HD) patients. Nevertheless it may be difficult to obtain and/or to use AVF in elderly. With this prospective randomised pilot study, we compare two strategies of vascular access in 70 years old or more new HD patients. AVF were compared to tunnelled jugular vein catheters (TIJC) with taurolidine as bacterial lock solution. Results were as follow: [table: see text] The responses with the visual analogic scale of comfort was 8/10 for TIJC and 5/10 with AVF * Ptaurolidine because of partial clotting of catheters. Albuminemia was significantly lower in AVF failure patients compared to AVF success patients (24.8g/L vs 31.1g/L). This pilot study allows to conclude that TIJC is an acceptable challenge to AVF in haemodialysed patients of 70 years or more in a two years long use.

  16. Arterio-venous concentration difference of [51Cr]EDTA after a single injection in man. Significance of renal function and local blood flow

    DEFF Research Database (Denmark)

    Rehling, M; Hyldstrup, L; Henriksen, Jens Henrik Sahl

    1989-01-01

    The present investigation was undertaken in order to study (1) the difference in arterial (Ca) and venous (Cv) concentration of [51Cr]EDTA (ethylenediaminetetraacetate) after a single intravenous injection, (2) the impact of different physiological variables on this difference, and (3) the error......, and 180-300 min post-injection (p.i.) Cv was 5.9% higher than Ca (range 0.5-13.9%, P less than 0.001). The more reduced renal function, the smaller was the concentration difference. The areas under the arterial and the venous plasma concentration curves did not differ significantly at either 0-infinity...... or 0-300 min p.i. whereas the venous area 0-100 min p.i. underestimated the arterial area in the same period by 4.1% (P less than 0.05). In a computer simulation model, variation in the forearm capillary permeability-surface area product did not have any significant influence on the Cv-Ca difference...

  17. Role of far infra-red therapy in dialysis arterio-venous fistula maturation and survival: systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Khalid Bashar

    Full Text Available A well-functioning arteriovenous fistula (AVF is the best modality for vascular access in patients with end-stage renal disease (ESRD requiring haemodialysis (HD. However, AVFs' main disadvantage is the high rate of maturation failure, with approximately one third (20%-50% not maturing into useful access. This review examine the use of Far-Infra Red therapy in an attempt to enhance both primary (unassisted and secondary (assisted patency rates for AVF in dialysis and pre-dialysis patients.We performed an online search for observational studies and randomised controlled trials (RCTs that evaluated FIR in patients with AVF. Eligible studies compared FIR with control treatment and reported at least one outcome measure relating to access survival. Primary patency and secondary patency rates were the main outcomes of interest.Four RCTs (666 patients were included. Unassisted patency assessed in 610 patients, and was significantly better among those who received FIR (228/311 compared to (185/299 controls (pooled risk ratio of 1.23 [1.12-1.35], p = 0.00001. In addition, the two studies which reported secondary patency rates showed significant difference in favour of FIR therapy--160/168 patients--compared to 140/163 controls (pooled risk ratio of 1.11 [1.04-1.19], p = 0.003.FIR therapy may positively influence the complex process of AVF maturation improving both primary and secondary patency rates. However blinded RCTs performed by investigators with no commercial ties to FIR therapy technologies are needed.

  18. Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.

    Directory of Open Access Journals (Sweden)

    Vatshalan Santhirapala

    Full Text Available BACKGROUND: Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO2, and haemoglobin saturation (SaO2, are the indices used in clinical assessments, and usually result from low inspired oxygen concentrations, or alveolar/airways disease. Our objective was to examine low blood oxygen/haemoglobin relationships in chronically compensated states without concurrent hypoxic pulmonary vasoreactivity. METHODOLOGY: 165 consecutive unselected patients with pulmonary arteriovenous malformations were studied, in 98 cases, pre/post embolisation treatment. 159 (96% had hereditary haemorrhagic telangiectasia. Arterial oxygen content was calculated by SaO2 x haemoglobin x 1.34/100. PRINCIPAL FINDINGS: There was wide variation in SaO2 on air (78.5-99, median 95% but due to secondary erythrocytosis and resultant polycythaemia, SaO2 explained only 0.1% of the variance in arterial oxygen content per unit blood volume. Secondary erythrocytosis was achievable with low iron stores, but only if serum iron was high-normal: Low serum iron levels were associated with reduced haemoglobin per erythrocyte, and overall arterial oxygen content was lower in iron deficient patients (median 16.0 [IQR 14.9, 17.4]mls/dL compared to 18.8 [IQR 17.4, 20.1]mls/dL, p<0.0001. Exercise tolerance appeared unrelated to SaO2 but was significantly worse in patients with lower oxygen content (p<0.0001. A pre-defined athletic group had higher Hb:SaO2 and serum iron:ferritin ratios than non-athletes with normal exercise capacity. PAVM embolisation increased SaO2, but arterial oxygen content was precisely restored by a subsequent fall in haemoglobin: 86 (87.8% patients reported no change in exercise tolerance at post-embolisation follow-up. SIGNIFICANCE: Haemoglobin and oxygen measurements in isolation do not indicate the more physiologically relevant

  19. A Non-Dimensional Analysis of Cardiovascular Response to Cold Stress. Part I. Identification of the Physical Parameters that Govern the Thermoregulatory Function of the Cardiovascular System.

    Science.gov (United States)

    1983-09-01

    13. Cortisone (from Adrenal), 14. Hydrocortisone, or Cortisol (from Adrenal), 15. Corticosterones "A", "B", or "S" (from Adrenal), 16. Epinephrine...widened arterio-venous-oxygen-difference. Moreover, blood coming back to the lungs with less oxygen, by the same mechanism, is able to extract more oxygen...or exist in duplicate (e.g., kidneys, liver, lungs ), or can still function under anaerobic or ischemic conditions (e.g., muscle), or are larger than

  20. Improved PNIPAAm-Hydrogel Photopatterning by Process Optimisation with Respect to UV Light Sources and Oxygen Content

    Directory of Open Access Journals (Sweden)

    Sebastian Haefner

    2016-03-01

    Full Text Available Poly-N-isopropylacrylamide (PNIPAAm hydrogels, known for their sensor and actuator capabilities, can be photolithographically structured for microsystem applications. For usage in microsystems, the preparation, and hence the characteristics, of these hydrogels (e.g., degree of swelling, size, cooperative diffusion coefficient are key features, and have to be as reproducible as possible. A common method of hydrogel fabrication is free radical polymerisation using a thermally-initiated system or a photoinitiator system. Due to the reaction quenching by oxygen, the polymer solution has to be rinsed with protective inert gases like nitrogen or argon before the polymerisation process. In this paper, we focus on the preparation reproducibility of PNIPAAm hydrogels under different conditions, and investigate the influence of oxygen and the UV light source during the photopolymerisation process. The flushing of the polymer solution with inert gas is not sufficient for photostructuring approaches, so a glove box preparation resulting in better quality. Moreover, the usage of a wide-band UV light source yields higher reproducibility to the photostructuring process compared to a narrow-band UV source.

  1. Long term analysis of the biomass content in the feed of a waste-to-energy plant with oxygen-enriched combustion air.

    Science.gov (United States)

    Fellner, Johann; Cencic, Oliver; Zellinger, Günter; Rechberger, Helmut

    2011-10-01

    Thermal utilization of municipal solid waste and commercial wastes has become of increasing importance in European waste management. As waste materials are generally composed of fossil and biogenic materials, a part of the energy generated can be considered as renewable and is thus subsidized in some European countries. Analogously, CO(2) emissions of waste incinerators are only partly accounted for in greenhouse gas inventories. A novel approach for determining these fractions is the so-called balance method. In the present study, the implementation of the balance method on a waste-to-energy plant using oxygen-enriched combustion air was investigated. The findings of the 4-year application indicate on the one hand the general applicability and robustness of the method, and on the other hand the importance of reliable monitoring data. In particular, measured volume flows of the flue gas and the oxygen-enriched combustion air as well as corresponding O(2) and CO(2) contents should regularly be validated. The fraction of renewable (biogenic) energy generated throughout the investigated period amounted to between 27 and 66% for weekly averages, thereby denoting the variation in waste composition over time. The average emission factor of the plant was approximately 45 g CO(2) MJ(-1) energy input or 450 g CO(2) kg(-1) waste incinerated. The maximum error of the final result was about 16% (relative error), which was well above the error (<8%) of the balance method for plants with conventional oxygen supply.

  2. Thermodynamic analyses of structural phase transition of Pr{sub 2}NiO{sub 4+δ} involving variation of oxygen content

    Energy Technology Data Exchange (ETDEWEB)

    Niwa, Eiki, E-mail: e-niwa@phys.chs.nihon-u.ac.jp [Department of Physics, College of Humanities and Sciences, Nihon University, 3-8-1 Sakurajousui, Setagaya-ku, Tokyo 156-8550 (Japan); Wakai, Kazuya [Department of Integrated Sciences in Physics and Biology, College of Humanities and Sciences, Nihon University, 3-8-1 Sakurajousui, Setagaya-ku, Tokyo 156-8550 (Japan); Hori, Tetsuya; Yashiro, Keiji; Mizusaki, Junichiro [Institute of Multidisciplinary Research for Advance Materials, Tohoku University, Sendai 980-8577 (Japan); Hashimoto, Takuya [Department of Integrated Sciences in Physics and Biology, College of Humanities and Sciences, Nihon University, 3-8-1 Sakurajousui, Setagaya-ku, Tokyo 156-8550 (Japan)

    2014-01-10

    Graphical abstract: - Highlights: • P(O{sub 2}) dependence of phase transition behavior of Pr{sub 2}NiO{sub 4+δ} was investigated. • The structural phase transition was measured by DSC and TG–DTA. • ΔH and ΔS of Pr{sub 2}NiO{sub 4+δ} were confirmed to be almost constant against P(O{sub 2}). • Variation of oxygen content at the phase transition, Δδ changed by P(O{sub 2}). • The origin of different Δδ by P(O{sub 2}) is valence change of Pr ion. - Abstract: Structural phase transition behavior of Pr{sub 2}NiO{sub 4+δ}, which attracts interest as new cathode material for solid oxide fuel cells, was investigated by DSC and TG–DTA under controlled oxygen partial pressure, P(O{sub 2}). It was revealed that the structural phase transition from orthorhombic phase to tetragonal phase involved discrete decrease of oxygen content in Pr{sub 2}NiO{sub 4+δ} and that the phase transition temperature, T{sub p}, decreased with decreasing P(O{sub 2}). Variation of enthalpy, ΔH, and entropy, ΔS, at the phase transition per one molar Pr{sub 2}NiO{sub 4+δ} were calculated from the peak area of DSC and they were independent on P(O{sub 2}) between 1.0 × 10{sup −1} bar and 2.25 × 10{sup −3} bar. From the linear relationships between T{sub p} and RT{sub p}ln P(O{sub 2}) and between 1/T{sub p} and Rln P(O{sub 2}), variation of standard enthalpy, ΔH°, and standard entropy, ΔS°, of the phase transition per one molar O{sub 2} were calculated, showing fair agreement with ΔH and ΔS. The variation of oxygen content at the phase transition, Δδ, increased with decreasing P(O{sub 2}), which can be attributed to valence variation of Pr in tetragonal Pr{sub 2}NiO{sub 4+δ} by P(O{sub 2})

  3. Hydrogen in oxygen-free, phosphorus-doped copper - Charging techniques, hydrogen contents and modelling of hydrogen diffusion and depth profile

    Energy Technology Data Exchange (ETDEWEB)

    Martinsson, Aasa [Swerea KIMAB, Kista (Sweden); Sandstroem, Rolf [Swerea KIMAB, Kista (Sweden); Div. of Materials Science and Engineering, KTH Royal Institute of Technology, Stockholm (Sweden); Lilja, Christina [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)

    2013-01-15

    In Sweden spent nuclear fuel is planned to be disposed of by encapsulating in cast iron inserts protected by a copper shell. The copper can be exposed to hydrogen released during corrosion processes in the inserts. If the hydrogen is taken up by the copper, it could lead to hydrogen embrittlement. Specimens from oxygen-free copper have been hydrogen charged using two different methods. The purpose was to investigate how hydrogen could be introduced into copper in a controlled way. The thermal charging method resulted in a reduction of the initial hydrogen content. After electrochemical charging of cylindrical specimens, the measured hydrogen content was 2.6 wt. ppm which should compared with 0.6 wt. ppm before charging. The retained hydrogen after two weeks was reduced by nearly 40%. Recently the paper 'Hydrogen depth profile in phosphorus-doped, oxygen-free copper after cathodic charging' (Martinsson and Sandstrom, 2012) has been published. The paper describes experimental results for bulk specimens as well as presenting a model. Almost all the hydrogen is found to be located less than 100 {mu}m from the surface. This model is used to interpret the experimental results on foils in the present report. Since the model is fully based on fundamental equations, it can be used to analyse what happens in new situations. In this report the effect of the charging intensity, the grain size, the critical nucleus size for hydrogen bubble formation as well as the charging time are analysed.

  4. The Cold Dust Content of the Oxygen-Rich Supernova Remnant G292.0+1.8

    CERN Document Server

    Ghavamian, Parviz

    2016-01-01

    We present far-infrared images of the Galactic oxygen-rich supernova remnant (SNR) G292.0+1.8, acquired with the PACS and SPIRE instruments of the Herschel Space Observatory. We find that the SNR shell is detected in the PACS blue (100 micron) band, but not in the red (160 micron) band, broadly consistent with results from AKARI observations. There is no discernible emission from G292.0+1.8 in SPIRE imagery at 250, 350 and 500 micron. Comparing the 100 micron emission to that observed with Spitzer, at 24 and 70 micron, we find a very similar appearance for G292.0+1.8 at all three wavelengths. The IR emission is dominated by dust from non-radiative circumstellar shocks. In addition, the radiatively shocked O-rich clump known as the 'Spur' on the eastern side of G292.0+1.8, is clearly detected in the PACS blueimages, with marginal detection in the red. Fitting the existing 14-40 micron IRS spectra of the Spur together with photometric measurements from 70 micron MIPS and 100 micron PACS photometry, we place an ...

  5. Preparation of high-content hexagonal boron nitride composite film and characterization of atomic oxygen erosion resistance

    Science.gov (United States)

    Zhang, Yu; Li, Min; Gu, Yizhuo; Wang, Shaokai; Zhang, Zuoguang

    2017-04-01

    Space aircrafts circling in low earth orbit are suffered from highly reactive atomic oxygen (AO). To shield AO, a flexible thin film with 80 wt.% hexagonal boron nitride (h-BN) and h-BN/epoxy film were fabricated through vacuum filtration and adding nanofibrillated cellulose fibers. H-BN nanosheets were hydroxylated for enhancing interaction in the films. Mass loss and erosion yield at accumulated AO fluence about 3.04 × 1020 atoms/cm2 were adopted to evaluate the AO resistance properties of the films. A carpet-like rough surface, chemical oxidations and change in crystal structure of h-BN were found after AO treatment, and the degrading mechanism was proposed. The mass loss and erosion yield under AO attack were compared between h-BN film and h-BN/epoxy film, and the comparison was also done for various types of shielding AO materials. Excellent AO resistance property of h-BN film is shown, and the reasons are analyzed.

  6. Speed associated with plasma pH, oxygen content, total protein and urea in an 80 km race.

    Science.gov (United States)

    Hoffman, R M; Hess, T M; Williams, C A; Kronfeld, D S; Griewe-Crandell, K M; Waldron, J E; Graham-Thiers, P M; Gay, L S; Splan, R K; Saker, K E; Harris, P A

    2002-09-01

    To test the hypothesis that endurance performance may be related quantitatively to changes in blood, we measured selected blood variables then determined their reference ranges and associations with speed during an 80 km race. The plan had 46 horses in a 2 x 2 factorial design testing a potassium-free electrolyte mix and a vitamin supplement. Blood samples were collected before the race, at 21, 37, 56 and 80 km, and 20 min after finishing, for assay of haematocrit, plasma pH, pO2, pCO2, [Na+], [K+], [Ca++], [Mg++], [Cl-], lactate, glucose, urea, cortisol, alpha-tocopherol, ascorbate, creatine kinase, aspartate amino transferase, lipid hydroperoxides, total protein, albumin and creatinine, and erythrocyte glutathione and glutathione peroxidase. Data from 34 finishers were analysed statistically. Reference ranges for resting and running horses were wide and overlapping and, therefore, limiting with respect to evaluation of individual horses. Speed correlations were most repeatable, with variables reflecting blood oxygen transport (enabling exercise), acidity and electrolytes (limiting exercise) and total protein (enabling then, perhaps, limiting). Stepwise regressions also included plasma urea concentration (limiting). The association of speed with less plasma acidity and urea suggests the potential for fat adaptation and protein restriction in endurance horses, as found previously in Arabians performing repeated sprints. Conditioning horses fed fat-fortified and protein-restricted diets may not only improve performance but also avoid grain-associated disorders.

  7. 烟气含氧量软测量方法研究%Research on the Soft Sensing Methods of Oxygen Content in Flue Gas

    Institute of Scientific and Technical Information of China (English)

    李健; 张彬文

    2016-01-01

    For solving some problems in detection process of the oxygen content in flue gas, the main factors influencing measurement of Zirconia analyzer are analyzed. Soft measurement technology provides a new measuring method for Oxygen content in flue gas. The common seen modeling methods for soft sensing of oxygen content in flue gas are given, and the key technologies including selection and processing of secondary variables, selection and processing of samples, calibration of dominant variable, and model updating and correction, etc. , are analyzed emphatically. The analysis shows that although the soft sensing model offers higher accuracy and higher dynamic response speed, some of the problems in direct measurement still cannot be resolved, such as big error, time lagging and so on. Because of hardware measurement is used as a reference of soft measurement model, the aspects of hardware should be firstly considered in improving measurement precision and speed accordingly.%针对火电厂烟气含氧量测量过程中存在的一些问题,分析了氧化锆氧分析器运行中的主要影响因素。软测量技术为烟气含氧量提供了新的测量手段。给出了常见的烟气含氧量软测量建模方法,并且重点分析了软测量建模过程中辅助变量的选取与处理、样本的选择与处理、主导变量的校准以及模型的更新校正等关键技术。分析表明,尽管软测量模型具有较高的精度和动态响应速度,但是现有的研究并不能完全解决直接测量结果误差大、滞后等问题。由于软测量模型以硬件测量作为参考,因此应首先考虑从硬件方面提升测量的精准度和响应速度。

  8. The Cold Dust Content of the Oxygen-rich Supernova Remnant G292.0+1.8

    Science.gov (United States)

    Ghavamian, Parviz; Williams, Brian J.

    2016-11-01

    We present far-infrared images of the Galactic oxygen-rich supernova remnant (SNR) G292.0+1.8, acquired with the PACS and SPIRE instruments of the Herschel Space Observatory. We find that the SNR shell is detected in the PACS blue (100 μm) band, but not in the red (160 μm) band, broadly consistent with results from AKARI observations. There is no discernible emission from G292.0+1.8 in SPIRE imagery at 250, 350 and 500 μm. Comparing the 100 μm emission to that observed with Spitzer at 24 and 70 μm, we find a very similar appearance for G292.0+1.8 at all three wavelengths. The infrared emission is dominated by dust from non-radiative circumstellar shocks. In addition, the radiatively shocked O-rich clump known as the “Spur” on the eastern side of G292.0+1.8 is clearly detected in the PACS blue images, with marginal detection in the red. Fitting the existing 14-40 μm IRS spectra of the Spur together with photometric measurements from 70 μm MIPS and 100 μm PACS photometry, we place an upper limit of ≲ 0.04 M ⊙ of ejecta dust mass in the Spur, under the most conservative assumption that the ejecta dust has a temperature of 15 K. Modeling the dust continuum in the IRS spectra at four positions around the rim, we estimate post-shock densities ranging from {n}p=3.5 cm-3 to 11 cm-3. The integrated spectrum of the entire SNR, dominated by swept-up circumstellar dust, can be fitted with a two-component dust model with a silicate component at 62 K and graphite component at 40 K for a total dust mass of 0.023 M ⊙.

  9. Cloud information content analysis of multi-angular measurements in the oxygen A-band: application to 3MI and MSPI

    Science.gov (United States)

    Merlin, Guillaume; Riedi, Jérôme; Labonnote, Laurent C.; Cornet, Céline; Davis, Anthony B.; Dubuisson, Phillipe; Desmons, Marine; Ferlay, Nicolas; Parol, Frédéric

    2016-10-01

    Information content analyses on cloud top altitude (CTOP) and geometrical thickness (CGT) from multi-angular A-band measurements in the case of monolayer homogeneous clouds are conducted. In the framework of future multi-angular radiometer development, we compared the potential performances of the 3MI (Multi-viewing, Multi-channel and Multi-polarization Imaging) instrument developed by EUMETSAT, which is an extension of POLDER/PARASOL instrument and MSPI (Multiangle SpectroPolarimetric Imager) developed by NASA's Jet Propulsion Laboratory. Quantitative information content estimates were realized for thin, moderately opaque and opaque clouds for different surface albedo and viewing geometry configurations. Analyses show that retrieval of CTOP is possible with a high accuracy in most of the cases investigated. Retrieval of CGT is also possible for optically thick clouds above a black surface, at least when CGT > 1-2 km and for thin clouds for CGT > 2-3 km. However, for intermediate optical thicknesses (COT ≃ 4), we show that the retrieval of CGT is not simultaneously possible with CTOP. A comparison between 3MI and MSPI shows a higher information content for MSPI's measurements, traceable to a thinner filter inside the oxygen A-band, yielding higher signal-to-noise ratio for absorption estimation. Cases of cloud scenes above bright surfaces are more complex but it is shown that the retrieval of CTOP remains possible in almost all situations while the information content on CGT appears to be insufficient in many cases, particularly for COT < 4 and CGT < 2-3 km.

  10. Oxygen and hydrogen stable isotope content in daily-collected precipitation samples at Dome C, East Antarctica

    Science.gov (United States)

    Dreossi, Giuliano; Stenni, Barbara; Del Guasta, Massimo; Bonazza, Mattia; Grigioni, Paolo; Karlicek, Daniele; Mognato, Riccardo; Scarchilli, Claudio; Turchetti, Filippo; Zannoni, Daniele

    2016-04-01

    Antarctic ice cores allow to obtain exceptional past climate records, thanks to their water stable isotope content, which provides integrated tracers of the atmospheric water cycle and local climate. Low accumulation sites of the East Antarctic plateau provide the oldest ice core records, with the record-breaking EPICA Dome C drilling covering the last eight climate cycles. However, the isotope-temperature relationship, commonly used to derive the temperature, may be characterized by significant geographical and temporal variations. Moreover, post-depositional effects may further complicate the climate interpretation. A continuous series of precipitation data is needed in order to gain a better understanding of the factors affecting the water stable isotopes in Antarctic precipitation at a specific site. In this study, we use the first and so-far only multi-year series of daily precipitation sampling and isotope measurements from the French-Italian Concordia Station, located at Dome C in East Antarctica (75°06'S 123°21'E; elevation: 3233 m a.s.l.; mean annual temperature: -54.5°C; snow accumulation rate: 25 kg m-2 yr-1), where the oldest deep Antarctic ice core has been retrieved. Surface air temperature data have been provided by the US automatic weather station (AWS), placed 1.5 km away from the base, while tropospheric temperature profiles are obtained by means of a radiosonde, launched once per day by the IPEV/Italian Antarctic Meteo-climatological Observatory. The new dataset also enables us for the first time to study the isotope-temperature relationship distinguishing between different types of precipitation, namely diamond dust, hoar frost and snowfall, identified by the observations carried out by the winter-over personnel collecting the snow samples. Here we present the complete data series of water stable isotopes in precipitation at Dome C spanning the time period from 2008 to 2014, in the framework of the PNRA PRE-REC project.

  11. Repeatability of Blood Gas Parameters, Pco2 Gap, and Pco2 Gap to Arterial-to-Venous Oxygen Content Difference in Critically Ill Adult Patients

    Science.gov (United States)

    Mallat, Jihad; Lazkani, Ali; Lemyze, Malcolm; Pepy, Florent; Meddour, Mehdi; Gasan, Gaëlle; Temime, Johanna; Vangrunderbeeck, Nicolas; Tronchon, Laurent; Thevenin, Didier

    2015-01-01

    Abstract The objective of this study was to examine the repeatability of blood gas (BG) parameters and their derived variables such as the central venous-to-arterial carbon dioxide tension difference (▵Pco2) and the ratio of ▵Pco2 over the central arteriovenous oxygen content difference (▵Pco2/C(a-cv)O2) and to determine the smallest detectable changes in individual patients. A total of 192 patients with arterial and central venous catheters were included prospectively. Two subsequent arterial and central venous blood samples were collected immediately one after the other and analyzed using the same point-of-care BG analyzer. The samples were analyzed for arterial and venous BG parameters, ▵Pco2, and ▵Pco2/C(a-cv)O2 ratio. Repeatability was expressed as the smallest detectable difference (SDD) and the least significant change (LSC). A change in value of these parameters exceeding the SDD or the LSC should be regarded as real. The SDDs for arterial carbon dioxide tension, arterial oxygen saturation, central venous oxygen saturation (ScvO2), and ▵Pco2 were small: ±2.06 mm Hg, ±1.23%, 2.92%, and ±1.98 mm Hg, respectively, whereas the SDDs for arterial oxygen tension (Pao2) and ▵Pco2/C(a-cv)O2 were high: ±9.09 mm Hg and ±0.57 mm Hg/mL, respectively. The LSCs (%) for these variables were 5.06, 1.27, 4.44, 32.4, 9.51, and 38.5, respectively. The repeatability of all these variables was good except for Pao2 and ▵Pco2/C(a-cv)O2 ratio for which we observed an important inherent variability. Expressed as SDD, a ScvO2 change value of at least ±3% should be considered as true. The clinician must be aware that an apparent change in these variables in an individual patient might represent only an inherent variation. PMID:25621691

  12. Genesis of high-Mg andesites (HMA) through shallow fractionation of primitive arc basalts at elevated oxygen fugacities (and low initial water contents)

    Science.gov (United States)

    Zellmer, Georg; Shellnutt, Gregory

    2010-05-01

    The petrogenesis of high-Mg andesites has been linked to a variety of processes, including partial melting of hydrous mantle peridotite, re-equilibration of partial melts of the subducting slab with the mantle wedge, and assimilation of lower crustal cumulates into dacitic melts. Yet none of these processes can explain the recently identified association of adakitic andesites, many of which are high-Mg andesites, with regions of elevated surface heat flux that are related to unusually shallow magma ponding levels in the upper crust (Zellmer, 2009). Using MELTS modeling, we demonstrate here that at elevated oxygen fugacities (NNO+2, which based on whole-rock Fe3+/Fe2+ ratios is appropriate for the Western and Central Aleutians, the Trans-Mexican Volcanic Belt, and the Setouchi Volcanic Belt), shallow crustal pressures (0.7 kbar), and initial H2O contents between 0.5 and 4 wt%, iron-magnesium spinel will be fractionated from primitive arc basalts, producing andesitic residual melts with elevated Mg#. Subsequent assimilation of a few percent of autocrystic mafic phases makes typical high-Mg andesites with forsteritic olivines. Orthopyroxenes in equilibrium with these melts are Cr-rich due to increased uptake of Cr into orthopyroxene (Dopx-lq ≥25) at lower temperatures (≤1130° C) and elevated oxygen fugacities (NNO+2). While arc magmas with high initial H2O contents will undergo early degassing induced crystallization and viscous stagnation, lower primary melt H2O contents will result in delayed crystallization and shallower magma ponding levels, accounting for elevated surface heat flux. Our findings are therefore consistent with the location of many high-Mg andesites in areas of high surface heat flux, and challenge the commonly accepted notion that these compositions are particularly hydrous primary melts generated in equilibrium with mantle peridotite. Reference: Zellmer G.F. (2009) Petrogenesis of Sr-rich adakitic rocks at volcanic arcs: insights from global

  13. Analysis of Direct-current Boiler Oxygen Content Control Based on the MINITAB%基于 MINITAB 的直流锅炉氧量控制分析

    Institute of Scientific and Technical Information of China (English)

    郭斌

    2012-01-01

      The article mainly compares the common oxygen content control curve of 600MW direct-current boiler. By using of the advanced statistical and analysis tools of MINITAB to identify the best range of oxygen content of 600MW direct-current Boiler, the oxygen content control curve is optimized. The boiler exhaust heat loss is therefore reduced, the boiler efficiency improved and the adjustment of boiler combustion instructed.%  对比600MW 直流锅炉常用氧量调整经验曲线,利用 MINITAB 高级统计分析工具,找出600MW 直流锅炉各负荷段氧量的最佳范围,优化氧量运行曲线,降低锅炉排烟损失,提高锅炉效率,指导运行调整。

  14. Cloud information content analysis of multi-angular measurements in the oxygen A-band: application to 3MI and MSPI

    Directory of Open Access Journals (Sweden)

    G. Merlin

    2015-12-01

    Full Text Available The vertical distribution of cloud cover has a significant impact on a large number of meteorological and climatic processes. Cloud top altitude and cloud geometrical thickness are then essential. Previous studies established the possibility of retrieving those parameters from multi-angular oxygen A-band measurements. Here we perform a study and comparison of the performances of future instruments. The 3MI (Multi-angle, Multi-channel and Multi-polarization Imager instrument developed by EUMETSAT, which is an extension of the POLDER/PARASOL instrument, and MSPI (Multi-angles Spectro-Polarimetric Imager develoloped by NASA's Jet Propulsion Laboratory will measure total and polarized light reflected by the Earth's atmosphere–surface system in several spectral bands (from UV to SWIR and several viewing geometries. Those instruments should provide opportunities to observe the links between the cloud structures and the anisotropy of the reflected solar radiation into space. Specific algorithms will need be developed in order to take advantage of the new capabilities of this instrument. However, prior to this effort, we need to understand, through a theoretical Shannon information content analysis, the limits and advantages of these new instruments for retrieving liquid and ice cloud properties, and especially, in this study, the amount of information coming from the A-Band channel on the cloud top altitude (CTOP and geometrical thickness (CGT. We compare the information content of 3MI A-Band in two configurations and that of MSPI. Quantitative information content estimates show that the retrieval of CTOP with a high accuracy is possible in almost all cases investigated. The retrieval of CGT seems less easy but possible for optically thick clouds above a black surface, at least when CGT > 1–2 km.

  15. 氧对焊缝金属吸氮机制的影响%EFFECT OF OXYGEN CONTENT ON NITROGEN ABSORPTIVE MECHANISM IN WELD FOR FLUX-CORED WIRE

    Institute of Scientific and Technical Information of China (English)

    冯灵芝; 张智; 张文钺

    2001-01-01

    By measuring the content of oxygen and nitrogen in welds of six kinds of self-shielded flux-cored wires,the effect of oxygen on nitrogen content in weld is studied and the different absorptive mechanisms of nitrogen at a low oxygen level([O] lower than 0.02%) and a high oxygen level ([O] higher than 0.03%) have been disco ve red.The results indicate that the content of nitrogen in weld can be made lowest by modifying the composition of flux and controlling the content of oxygen to the range of 0.02%~0.03%.%通过测定6种焊缝中的氮、氧含量,研究了氧对焊缝金属吸氮量的影响,发现液态金属在低氧([O]<0.02%)和高氧([O]>0.03%)条件下不同的吸氮机制,并且提出通过调整药芯成分,将焊缝氧含量控制在0.02%~0.03%范围内,可使焊缝吸氮量最低.

  16. Effect of Zr Purity and Oxygen Content on the Structure and Mechanical Properties of Melt-Spun and Suction-Cast Cu46Zr42Al7Y5 Alloy

    OpenAIRE

    Kozieł T.; Latuch J.; Cios G.; Bała P.

    2016-01-01

    The effect of oxygen content in zirconium on the structure and mechanical properties of the Cu46Zr42Al7Y5 alloy, in the form of melt-spun ribbons and suction-cast rods, was investigated. Two types of Zr, rod and crystal bar of different nominal purities and oxygen contents, were used to synthesize the alloy by arc melting. Rapidly solidified ribbons were produced by melt spinning and their amorphous structures were confirmed by X-ray diffractometry (XRD) and differential scanning calorimetry ...

  17. Venoarterial PCO2-to-arteriovenous oxygen content difference ratio is a poor surrogate for anaerobic metabolism in hemodilution: an experimental study.

    Science.gov (United States)

    Dubin, Arnaldo; Ferrara, Gonzalo; Kanoore Edul, Vanina Siham; Martins, Enrique; Canales, Héctor Saúl; Canullán, Carlos; Murias, Gastón; Pozo, Mario Omar; Estenssoro, Elisa

    2017-12-01

    The identification of anaerobic metabolism in critically ill patients is a challenging task. Observational studies have suggested that the ratio of venoarterial PCO2 (Pv-aCO2) to arteriovenous oxygen content difference (Ca-vO2) might be a good surrogate for respiratory quotient (RQ). Yet Pv-aCO2/Ca-vO2 might be increased by other factors, regardless of anaerobic metabolism. At present, comparisons between Pv-aCO2/Ca-vO2 and RQ have not been performed. We sought to compare these variables during stepwise hemorrhage and hemodilution. Since anemia predictably produces augmented Pv-aCO2 and decreased Ca-vO2, our hypothesis was that Pv-aCO2/Ca-vO2 might be an inadequate surrogate for RQ. This is a subanalysis of a previously published study. In anesthetized and mechanically ventilated sheep (n = 16), we compared the effects of progressive hemodilution and hemorrhage by means of expired gases analysis. There were comparable reductions in oxygen consumption and increases in RQ in the last step of hemodilution and hemorrhage. The increase in Pv-aCO2/Ca-vO2 was higher in hemodilution than in hemorrhage (1.9 ± 0.2 to 10.0 ± 0.9 vs. 1.7 ± 0.2 to 2.5 ± 0.1, P < 0.0001). The increase in Pv-aCO2 was lower in hemodilution (6 ± 0 to 10 ± 1 vs. 6 ± 0 to 17 ± 1 mmHg, P < 0.0001). Venoarterial CO2 content difference and Ca-vO2 decreased in hemodilution and increased in hemorrhage (2.6 ± 0.3 to 1.2 ± 0.1 vs. 2.8 ± 0.2 to 6.9 ± 0.5, and 3.4 ± 0.3 to 1.0 ± 0.3 vs. 3.6 ± 0.3 to 6.8 ± 0.3 mL/dL, P < 0.0001 for both). In hemodilution, Pv-aCO2/Ca-vO2 increased before the fall in oxygen consumption and the increase in RQ. Pv-aCO2/Ca-vO2 was strongly correlated with Hb (R (2) = 0.79, P < 0.00001) and moderately with RQ (R (2) = 0.41, P < 0.0001). A multiple linear regression model found Hb, RQ, base excess, and mixed venous oxygen saturation and PCO2 as Pv-aCO2/Ca-vO2 determinants (adjusted R (2) = 0.86, P < 0.000001). In

  18. Low content Pt nanoparticles anchored on N-doped reduced graphene oxide with high and stable electrocatalytic activity for oxygen reduction reaction

    Science.gov (United States)

    Li, Zeyu; Gao, Qiuming; Zhang, Hang; Tian, Weiqian; Tan, Yanli; Qian, Weiwei; Liu, Zhengping

    2017-01-01

    A novel kind of Pt/N-rGO hybrid possessing of low content 5.31 wt.% Pt anchored on the surface of nitrogen doped reduced graphene oxide (N-rGO) evenly was prepared. The Pt has uniformed 2.8 nm diameter and exposed (111) crystal planes; meanwhile, the N works as the bridge between Pt and rGO with the Pt-N and N-C chemical bonds in Pt/N-rGO. The Pt/N-rGO material has a very high electrocatalytic activity in oxygen reduction reaction with the mass catalytic activity more than 1.5 times of the commercial Pt/C due to the synergistic catalytic effect of both N-doped carbon matrix and Pt nanoparticles. Moreover, the Pt/N-rGO exhibits an excellent stability with hardly loss (only 0.4%) after accelerated durability tests of 5000 cycles based on the stable Pt-N-C chemical bonds in Pt/N-rGO, which can prevent the detachment, dissolution, migration and aggregation of Pt nanoparticles on the matrix during the long-term cycling. PMID:28233857

  19. Low content Pt nanoparticles anchored on N-doped reduced graphene oxide with high and stable electrocatalytic activity for oxygen reduction reaction

    Science.gov (United States)

    Li, Zeyu; Gao, Qiuming; Zhang, Hang; Tian, Weiqian; Tan, Yanli; Qian, Weiwei; Liu, Zhengping

    2017-02-01

    A novel kind of Pt/N-rGO hybrid possessing of low content 5.31 wt.% Pt anchored on the surface of nitrogen doped reduced graphene oxide (N-rGO) evenly was prepared. The Pt has uniformed 2.8 nm diameter and exposed (111) crystal planes; meanwhile, the N works as the bridge between Pt and rGO with the Pt-N and N-C chemical bonds in Pt/N-rGO. The Pt/N-rGO material has a very high electrocatalytic activity in oxygen reduction reaction with the mass catalytic activity more than 1.5 times of the commercial Pt/C due to the synergistic catalytic effect of both N-doped carbon matrix and Pt nanoparticles. Moreover, the Pt/N-rGO exhibits an excellent stability with hardly loss (only 0.4%) after accelerated durability tests of 5000 cycles based on the stable Pt-N-C chemical bonds in Pt/N-rGO, which can prevent the detachment, dissolution, migration and aggregation of Pt nanoparticles on the matrix during the long-term cycling.

  20. Assessment of a modified and optimised method for determining chemical oxygen demand of solid substrates and solutions with high suspended solid content.

    Science.gov (United States)

    Raposo, F; de la Rubia, M A; Borja, R; Alaiz, M

    2008-07-15

    A modified approach to determine the chemical oxygen demand (COD) of solid substrates based on the DIN 38414-S9 standard method is proposed. The adapted procedure is assessed and compared with standard methods widely used for water and wastewater such as the American Public Health Association-American Water Works Association-Water Pollution Control Federation (APHA-AWWA-WPCF) standard methods 5220 B-open reflux (SM-OR) and 5220 D-closed reflux colorimetric (SM-CR). Solutions with high suspended concentration of solids, as well as digestates from an anaerobic reactor, were used during the comparative test. For solid substrates, the COD recovery was about 100% when the proposed method was used. For solutions with solid content higher than 20 g TS L(-1), the recovery was only completed when the proposed method was used, showing that the methods traditionally employed are not very appropriate for samples with the described characteristics. For instance, percentages of COD recovery in the ranges of 77.3-87.1% and 89.4-94.1% were achieved when the SM-OR and SM-CR methods were used, respectively.

  1. Black tattoo inks induce reactive oxygen species production correlating with aggregation of pigment nanoparticles and product brand but not with the polycyclic aromatic hydrocarbon content.

    Science.gov (United States)

    Høgsberg, Trine; Jacobsen, Nicklas Raun; Clausen, Per Axel; Serup, Jørgen

    2013-07-01

    Black tattoo inks are composed of carbon nanoparticles, additives and water and may contain polycyclic aromatic hydrocarbons (PAHs). We aimed to clarify whether reactive oxygen species (ROS) induced by black inks in vitro is related to pigment chemistry, physico-chemical properties of the ink particles and the content of chemical additives and contaminants including PAHs. The study included nine brands of tattoo inks of six colours each (black, red, yellow, blue, green and white) and two additional black inks of different brands (n = 56). The ROS formation potential was determined by the dichlorofluorescein (DCFH) assay. A semiquantitative method was developed for screening extractable organic compounds in tattoo ink based on gas chromatography-mass spectrometry (GC-MS) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Two black inks produced high amounts of ROS. Peroxyl radicals accounted for up to 72% of the free radicals generated, whereas hydroxyl radicals and H₂O₂ accounted for brands. Ten of 11 black inks had PAH concentrations exceeding the European Council's recommended level, and all 11 exceeded the recommended level for benzo(a)pyrene. It is a new finding that aggregation of tattoo pigment particles correlates with ROS production and brand, independently of chemical composition including PAHs. ROS is hypothesized to be implicated in minor clinical symptoms.

  2. Changes in oxygen content and acid-base balance in arterial and portal blood in response to the dietary electrolyte balance in pigs during a 9-h period after a meal

    NARCIS (Netherlands)

    Dersjant-Li, Y.; Verstegen, M.W.A.; Jansman, A.; Schulze, H.; Schrama, J.W.; Verreth, J.A.J.

    2002-01-01

    The effect of two dietary electrolyte balance (dEB, Na K - Cl-) levels on arterial and portal blood oxygen content, blood pH, and acid-base status in pigs was studied during a 9-h period after a meal, using a crossover experimental design. The dEB levels were established by changing the Cl- level in

  3. PENGARUH MINUMAN BEROKSIGEN TERHADAP SISTEM IMUN, KADAR MALONALDEHIDA DAN PERFORMA RESPONDEN MAHASISWA OLAHRAGAWAN [Effect of Oxygenated Water on Immune System, Malonaldehyde Content and Student-Athlete Performance

    OpenAIRE

    Cesar Welya Refdi; Fransiska Rungkat Zakaria; Puspo Edi Giriwono

    2014-01-01

    Exercise requires more oxygen input and cannot be fully obtained through breathing. The body has a homeostatic system, when more ATP is needed, the more oxygen is required by the body. Limited supply of oxygen such as those happens in athlete’s body automatically switches the respiration from aerobic into anaerobic. This situation results in building up of lactic acid which in turn lowers the energy for cellular metabolism as well asenergy for exercise. The purpose of this study was to assess...

  4. 元素分析仪法测定氧含量的研究%Study on Determination of Oxygen Content With Element Analyzer

    Institute of Scientific and Technical Information of China (English)

    孙琪娟; 徐军礼; 孙长顺

    2015-01-01

    Vario EL Ⅲ organic elemental analyzer can precisely determine C,H,O,N and S element contents in organic compounds. But it has the limitation for determining the organic compounds (because they include special hetero-atom). In order to solve the problem and expand its using scope, we use Vario EL Ⅲ organic elemental analyzer to determine some simple oxide compound precisely instead of organo-elemental compound. The results show that Vario EL Ⅲ organic elemental analyzer can be used to determine the oxygen content of some organic elemental compound and oxide compound. By measurement of a large number of oxides, combined with the periodic table of elements, the distribution rule of measurable elements can be found out, which could have guiding significance for using Vario EL III elemental analyzer to determine samples.%Vario EL Ⅲ元素分析仪在分析有机化合物中的 C、H、O、N、S 元素含量时能够达到相当高的精度。但对元素有机化合物的测量范围有限(由于其含有特殊的杂原子),为了解决其在测量有机元素化合物中氧元素方面的局限性,扩大仪器的使用范围,本研究以测定简单氧化物中的氧含量代替元素有机化合物,结果表明 Vario EL Ⅲ元素分析仪也可以用来测定部分氧化物和元素有机化合物中的氧含量。并通过测定大量氧化物,结合元素周期表找出了可测元素的分布规律,对以后使用 Vario EL Ⅲ元素分析仪测定样品的分析工作具有指导意义。

  5. Effect of Zr Purity and Oxygen Content on the Structure and Mechanical Properties of Melt-Spun and Suction-Cast Cu46Zr42Al7Y5 Alloy

    Directory of Open Access Journals (Sweden)

    Kozieł T.

    2016-06-01

    Full Text Available The effect of oxygen content in zirconium on the structure and mechanical properties of the Cu46Zr42Al7Y5 alloy, in the form of melt-spun ribbons and suction-cast rods, was investigated. Two types of Zr, rod and crystal bar of different nominal purities and oxygen contents, were used to synthesize the alloy by arc melting. Rapidly solidified ribbons were produced by melt spinning and their amorphous structures were confirmed by X-ray diffractometry (XRD and differential scanning calorimetry (DSC. Bulk samples in the form of rods were cast using a special water-cooled suction casting unit attached to the arc melting system. XRD and DSC studies proved the amorphous structure of the bulk alloy synthesized from low-oxygen Zr and partial crystallization of the same alloy for high-oxygen Zr. In both bulk samples, uniformly distributed crystalline particles were identified as yttrium oxides. Higher mean compressive strength of amorphous alloy was observed. The hardness of amorphous phase was close to 500 HV1 in both bulk alloys, while the hardness of crystalline dendritic areas, observed in the alloy synthesized from high oxygen Zr, was lower by about 50 HV1.

  6. 氧弹燃烧灰化法测定奶粉中的钙和磷%Determination the Content of Calcium and Phosphorus in Milk Powder by Oxygen Bomb

    Institute of Scientific and Technical Information of China (English)

    党民团; 刘娟

    2013-01-01

    Oxygen bomb combustion method, which destroys the organic substances, is both simple and convenient as well as fast in operation, and pollution free in element analysis. With satisfactory result, this method has been applied to the determination of the content of calcium and phosphorus in milk powder by ashes of oxygen bomb which proves to be valid and reliable.%用氧弹燃烧灰化法分解有机物进行元素测定,操作简便、快速、无污染.该方法用于测定奶粉中的钙和磷,结果可靠.

  7. Relationships between oxygen content, modulation period and superconducting property of Bi-based superconducting oxides. Bi kei sankabtsu chodendotai ni okeru sanso ganryo, hencho kozo oyobi chodendo tokusei no sokan

    Energy Technology Data Exchange (ETDEWEB)

    Deshimaru, Y.; Shimizu, Y.; Miura, N.; Yamazoe, N. (Kyushu Univ., Fukuoka (Japan). Graduate School of Engineering Sciences); Hiroi, Z.; Bando, Y. (Kyoto Univ., Kyoto (Japan). Inst. for Chemical Research)

    1992-09-10

    Two (2223 and 2212) of three superconducting phases in the Pb-doped Bi-Sr-Ca-Cu-O (BSCCO) oxide superconductor were examined for their changes of crystal structures and superconducting properties with changing oxygen content. Their oxygen sorption behavior examined by the temperature-programmed-desorption method showed that both samples desorb trace amounts of oxygen in a temperature range of 350-600 centigrade and the behavior examined by the temperature-programmed oxidation method showed that they absorb (absorb) reversibly oxygen desorbed above in a range of 100-350 centigrade. The critical temperature to bear diamagnetism (Tc) of the 2223 sample fell from 111 K to 96 K as oxygen was desorbed up to 600 centigrade. However, Tc recovers reversibly to the initial value when oxygen was re-absorbed. Contrary to the 2223, the 2212 sample showed the opposite Tc change. Both samples increased in their c-axes lengths and their modulation periods and the changes were reversible respectively. It was pointed out that the Tc behaviors of both sample systems were dependent on the concentration of holes on the CuO2 surfaces. 33 refs., 9 figs.

  8. The effect of oxygen content on the magnetic and transport properties of FeSr{sub 2}Y{sub 1.5}Ce{sub 0.5}Cu{sub 2}O{sub 8+x}

    Energy Technology Data Exchange (ETDEWEB)

    Sambale, Sebastian [MacDiarmid Institute for Advanced Materials and Nanotechnology, SCPS, Victoria University of Wellington, PO Box 600, Wellington 6140 (New Zealand); Robinson Research Institute, Victoria University of Wellington, PO Box 33436, Lower Hutt 5046 (New Zealand); Williams, Grant V.M., E-mail: Grant.Williams@vuw.ac.nz [MacDiarmid Institute for Advanced Materials and Nanotechnology, SCPS, Victoria University of Wellington, PO Box 600, Wellington 6140 (New Zealand); Chong, Shen V. [Robinson Research Institute, Victoria University of Wellington, PO Box 33436, Lower Hutt 5046 (New Zealand)

    2016-04-15

    The magnetic and transport properties of FeSr{sub 2}Y{sub 1.5}Ce{sub 0.5}Cu{sub 2}O{sub 8+x} have been studied in the oxygen saturated (OS) and oxygen reduced (OR) states. We find that the low temperature spin-glass transition is not affected by the oxygen content in the SrFeO{sub 3−x} subunit although the magnitude of the Curie–Weiss temperature is significantly larger in the OR sample. The oxygen reduced sample also has an antiferromagnetic transition at ~310 K that is likely to be due to antiferromagnetic ordering of the Cu moments in the CuO{sub 2} plane. The resistivity from the OR sample can be modeled in terms of variable range hopping and activated conduction, which indicates that it is a very disordered semiconductor. The oxygen saturated sample has additional holes in the CuO{sub 2} plane and the absence of superconductivity is likely due to pair breaking from Fe on the Cu sites in the CuO{sub 2} plane. We modeled the resistivity in the OS state in terms of inhomogeneous transport where there are metallic regions and disordered regions that have a resistivity with a 1/T{sup m} temperature dependence at low temperatures.

  9. Gas exchange kinetics following concentric-eccentric isokinetic arm and leg exercise.

    Science.gov (United States)

    Drescher, U; Mookerjee, S; Steegmanns, A; Knicker, A; Hoffmann, U

    2017-06-01

    To evaluate the effects of exercise velocity (60, 150, 240deg∙s(-1)) and muscle mass (arm vs leg) on changes in gas exchange and arterio-venous oxygen content difference (avDO2) following high-intensity concentric-eccentric isokinetic exercise. Fourteen subjects (26.9±3.1years) performed a 3×20-repetition isokinetic exercise protocol. Recovery beat-to-beat cardiac output (CO) and breath-by-breath gas exchange were recorded to determine post-exercise half-time (t1/2) for oxygen uptake (V˙O2pulm), carbon dioxide output (V˙CO2pulm), and ventilation (V˙E). Significant differences of the t1/2 values were identified between 60 and 150deg∙s(-1). Significant differences in the t1/2 values were observed between V˙O2pulm and V˙CO2pulm and between V˙CO2pulm and V˙E. The time to attain the first avDO2-peak showed significant differences between arm and leg exercise. The present study illustrates, that V˙O2pulm kinetics are distorted due to non-linear CO dynamics. Therefore, it has to be taken into account, that V˙O2pulm may not be a valuable surrogate for muscular oxygen uptake kinetics in the recovery phases. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. The significance of changes in cerebral oxygen and glucose metabolism in patients with cerebral hemorrhage caused by acute hypertension%急性高血压脑出血患者脑糖氧代谢变化及意义

    Institute of Scientific and Technical Information of China (English)

    马骏; 陈锷峰; 屠传建; 钱辉; 骆明; 顾志伟; 张建民

    2014-01-01

    Objective To study the clinical significance of early changes in cerebral oxygen and glucose metabolism in patients with cerebral hemorrhage and with Glasgow coma score (GCS) of 5-8 caused by acute hypertension in order to find relationship between those changes and prognosis.Methods From January 1,2011 to June 30,2012,a cohort of 43 patients with cerebral hemorrhage caused by acute hypertension were enrolled for retrospective study.Radial artery and internal jugular vein were separately cannulated retrogradely for collecting blood for blood gas analysis and blood glucose tests carried out 24 hours after the onset of the cerebral hemorrhage and then every 6-8 hours and as any major changes in physical signs of patients occurred.And this monitoring kept for consecutive 3 days.The data of these laboratory findings were analyzed and calculated to determine internal jugular vein oxygen saturation (SjVO2),cerebral oxygen utilization rate (CEO2),cerebral arterio-venous oxygen difference (AVDO2),arterio-venous blood glucose difference (V-Aglu),arterio-venous lactic acid difference (V-Alac) and absolute value of carbon dioxide pressure difference between jugular vein and artery (V-APCO2).All patients met the diagnostic criteria of hypertensive cerebral hemorrhage revised by the 4th National Academic Conference on cerebrovascular disease in 1995 requiring diagnosis confirmed by brain CT,admitted within 24 hours of onset,Glasgow coma score (GCS) 5-8 and a history of hypertension.Exclusion criteria were:cerebral hemorrhage caused by traumatic intracranial hematoma,spontaneous subarachnoid hemorrhage,arteriovenous malformation and Moyamoya disease,intracranial tumor apoplexy,cerebral bleeding derived from the disturbance of blood coagulation system,and cerebral hemorrhagic infarction.According to the short-term prognosis,the patients were divided into the death group and the survival group.Then the differences in biomarkers mentioned above between two groups were compared to

  11. Influence of Oxygen Content and Microstructure on the Mechanical Properties and Biocompatibility of Ti–15 wt%Mo Alloy Used for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    José R. S. Martins, Jr.

    2014-01-01

    Full Text Available The Ti–15Mo alloy has its mechanical properties strongly altered by heat treatments and by addition of interstitial elements, such as, oxygen, for example. In this sense, the objective of this paper is to analyze the effect of the introduction of oxygen in selected mechanical properties and the biocompatibility of Ti–15Mo alloy. The samples used in this study were prepared by arc-melting and characterized by density measurements, X-ray diffraction, scanning electron microscopy, microhardness, modulus of elasticity, and biocompatibility tests. Hardness measurements were shown to be sensitive to concentration of oxygen. The modulus results showed interstitial influence in value; this was verified under several conditions to which the samples were exposed. Cytotoxicity tests conducted in vitro showed that the various processing conditions did not alter the biocompatibility of the material.

  12. Oxygen Therapy

    Science.gov (United States)

    Oxygen therapy is a treatment that provides you with extra oxygen. Oxygen is a gas that your body needs to function. Normally, your lungs absorb oxygen from the air you breathe. But some conditions ...

  13. Bran data of total flavonoid and total phenolic contents, oxygen radical absorbance capacity, and profiles of proanthocyanidins and whole grain physical traits of 32 red and purple rice varieties

    Directory of Open Access Journals (Sweden)

    Ming-Hsuan Chen

    2016-09-01

    Full Text Available Phytochemicals in red and purple bran rice have potential health benefit to humans. We determined the phytochemicals in brans of 32 red and purple global rice varieties. The description of the origin and physical traits of the whole grain (color, length, width, thickness and 100-kernel weight of this germplasm collection are provided along with data of total flavonoid and total phenolic contents, oxygen radical absorbance capacity and total proanthocyanidin contents. The contents and proportions of individual oligomers, from degree of polymerization of monomers to 14-mers, and polymers in bran of these 32 rice varieties are presented (DOI: http://dx.doi.org/10.1016/j.foodchem.2016.04.004 [1].

  14. Bran data of total flavonoid and total phenolic contents, oxygen radical absorbance capacity, and profiles of proanthocyanidins and whole grain physical traits of 32 red and purple rice varieties.

    Science.gov (United States)

    Chen, Ming-Hsuan; McClung, Anna M; Bergman, Christine J

    2016-09-01

    Phytochemicals in red and purple bran rice have potential health benefit to humans. We determined the phytochemicals in brans of 32 red and purple global rice varieties. The description of the origin and physical traits of the whole grain (color, length, width, thickness and 100-kernel weight) of this germplasm collection are provided along with data of total flavonoid and total phenolic contents, oxygen radical absorbance capacity and total proanthocyanidin contents. The contents and proportions of individual oligomers, from degree of polymerization of monomers to 14-mers, and polymers in bran of these 32 rice varieties are presented (DOI: http://dx.doi.org/10.1016/j.foodchem.2016.04.004) [1].

  15. Oxygen permeable membrane for oxygen enriched combustion

    Energy Technology Data Exchange (ETDEWEB)

    Asakawa, S. (Matsushita Research Inst., Tokyo, Japan); Saito, Y.; Kawahito, M.; Ito, Y.; Tsuchiya, S.; Sugata, K.

    1983-02-01

    An oxygen enriched air production system using gas separation membranes has been developed to be used for fuel combustion systems. High oxygen permeable scopolymers, including three dimensional structure, have been synthesized through condensation of polyvinylphenol with some, ..cap alpha..,..omega..-bis (diethylamino) polydimethylsiloxanes. The experimental results showed that the oxygen permeability through the copolymer varies as a function of the dimethylsiloxane content of the copolymers. Such composition dependence of the oxygen permeability was explained on the basis of polymer constitution. Typical values of the oxygen permeability, 3.4 x 10/sup -8/ (cc x cm/cm/sup 2/ x sec x cmHg) and ..cap alpha.., 2.1, were obtained at 72% of dimethylsiloxane content. The copolymers are soluble in most common organic solvents and uniform, defect-free membranes as thin as 1000 Angstroms have been formed by spreading solutions of the copolymer on water. Composite membranes fabricated by applying the membranes to porous support materials were used for practical gas separation and 30% oxygen enriched air was produced from ambient air. A new type oxygen enriched combustion system, which is more efficient for energy saving, has been developed by utilizing oxygen enriched air thus produced. 15 references, 15 figures, 1 table.

  16. Oxygen intake in ion irradiated fullerene films

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Amit [Department of Nanosciences, Neel Institute, C.N.R.S., 25 rue des Martyrs, BP166 38042 Grenoble Cedex 9 (France); Materials Science Group, Inter University Accelerator Centre, P.O. Box 10502, New Delhi 110 067 (India)], E-mail: amit.kumar@grenoble.cnrs.fr; Khan, S.A. [Materials Science Group, Inter University Accelerator Centre, P.O. Box 10502, New Delhi 110 067 (India); Kumar, Manvendra [Physics Department, Allahabad University, P.O. Box 211002 (India); Agarwal, D.C. [RBS College, Agra (India); Singh, Fouran; Tripathi, A. [Materials Science Group, Inter University Accelerator Centre, P.O. Box 10502, New Delhi 110 067 (India); Govind; Shivaprasad, S.M. [Surface Physics and Nanostructures Group, NPL, New Delhi 110 060 (India); Salomon, J.; Pichon, L. [C2RMF, Palais du Louvre, 75001 Paris (France); Pivin, J.C. [CSNSM, 91405 Orsay Campus (France); Avasthi, D.K. [Department of Nanosciences, Neel Institute, C.N.R.S., 25 rue des Martyrs, BP166 38042 Grenoble Cedex 9 (France)

    2008-04-15

    The present work reports the change in the oxygen content in energetic ion irradiated fullerene films. The oxygen contents in irradiated films have been studied using on-line elastic recoil detection analysis (ERDA) and off-line X-ray photo electron emission (XPS) and nuclear reaction analysis (NRA) techniques. The XPS and NRA techniques show that the oxygen content increases with ion fluence, whereas on-line ERDA measurements reveal that the oxygen content decreases with ion fluence. These experiments give clear evidence that oxygen content in irradiated films increases after exposure to the atmospheric oxygen.

  17. Highest Oxygen Bar

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The world’s highest altitude Lhalu Wetland in Tibet is rebounding from past environmental damage In Lhasa, where the oxygen content is just 60 percent of that of the plain area, a place known as the "natural oxygen bar"is highly prized by residents.

  18. 不同温度下原油蒸气的爆炸极限和临界氧含量%Explosion limits and critical oxygen content of crude oil vapor at different ambient temperatures

    Institute of Scientific and Technical Information of China (English)

    刘振翼; 李浩; 邢冀; 黄平; 周轶

    2011-01-01

    An explosion accident is possible for process of oil recovery using air injection because of the existence of flammable mixture. So it is necessary to measure the explosion limits and the critical oxygen content of crude oil vapor at different temperatures from 15℃ to 150℃. The measurement result indicated that the explosion limit of crude oil vapor is 4. 62%-14.01% at 15℃ and 4.24%-15.62% at 150℃,while the critical oxygen is 13.15% at 15℃ and 12.47% at 150℃. The range of explosion limit widens and the critical oxygen content decreases with temperature increasing. The correlations between explosion limits as well as critical oxygen content and temperature are founded through numerical analysis, which could be used for forecasting the explosion limits and the critical oxygen content of crude oil at different temperatures.%注空气采油因其过程中存在可燃性混合物,会有发生爆炸事故的可能.通过实验测定了15~150℃之间5个初始温度点原油蒸气的爆炸极限和临界氧含量,15℃时爆炸极限范围为4.62%~14.01%,150℃时爆炸极限范围变宽为4.24%~15.62%,安全氧含量15℃时为13.15%,150℃时降低到12.47%,得出了原油蒸气爆炸极限范围随温度升高而变宽,临界氧含量随温度升高而降低的结论,并运用数值分析原理拟合出原油蒸气爆炸极限和临界氧含量各自随温度变化的规律函数,对预测原油蒸气在其他温度下的爆炸极限和临界氧含量有一定意义.

  19. 气相色谱法测定液氧中乙炔含量的试验研究%Experimental Study on the Measurement of the Content of Acetylene in Liquid Oxygen with Gas Chromatographic Method

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    The space division workshop of oxygen generation plant in a company adopts gas chromatographic method to determine the content of acetylene in liquid oxygen instead of the original visual colorimetric method, and through the comparison of the experimental data, the accuracy of gas chromatographic method analysis is raised substantially, which guarantees safety in production.%  某公司制氧厂空分车间原来采用目视比色法测定液氧中乙炔的含量,存在工艺复杂,消耗试剂多,误差大等缺点。采用气相色谱法代替原来的目视比色法,经试验数据对比,气相色谱法分析准确度大幅度提高,有效的保障了安全生产。

  20. Effects of anaesthesia induction drugs on circulation in denervated intestinal loop preparation.

    Science.gov (United States)

    Tverskoy, M; Gelman, S; Fowler, K C; Bradley, E L

    1985-09-01

    The effect of anaesthesia induction drugs on the intestinal circulation was evaluated in an isolated loop preparation in 28 dogs. Selected intestinal loops were perfused with aortic blood by a pump at a constant pressure of 100 mmHg. A mixture of 86Rb and 9 microns spheres labeled with 141Ce was injected into the arterial cannula supplying the intestinal segment while mesenteric venous blood was collected for activity counting. Diazepam in a dose of 3 mg X kg-1 was accompanied by a significantly lower clearance (Cl-Rb), and permeability-surface area product (PS) than pentobarbitone; there were no differences between diazepam and pentobarbitone in total blood flow (BF), vascular resistance (VR) and oxygen consumption in the intestinal segments. Circulatory variable observed after midazolam, 8 mg X kg-1 and an additional 16 mg X kg-1, did not significantly differ from those seen during pentobarbitone. Ketamine in a dose of 8 mg X kg-1 was accompanied by a significantly lower BF, Cl-Rb, microsphere entrapment (Cl-Sph), PS, and higher VR and arterio-venous oxygen content difference. Sixteen mg X kg-1 of ketamine did not lead to any additional changes in determined variables of the intestinal circulation. Alpha-adrenoceptor blockade completely abolished vasoconstriction caused by ketamine, suggesting that the long-lasting vasoconstricting effect of ketamine on the intestinal circulation is mediated through catecholamines.

  1. Transverse magnetoresistance of YBa{sub 2}Cu{sub 3}O{sub {ital x}} single crystals with different oxygen content

    Energy Technology Data Exchange (ETDEWEB)

    Amitin, E.B.; Blinov, A.G.; Boyarsky, L.A.; Dikovsky, V.Y.; Zhdanov, K.R.; Kameneva, M.Y.; Kochergin, O.M.; Naumov, V.N.; Frolova, G.I. [Institute of Inorganic Chemistry, Novosibirsk 630090 (Russian Federation); Demianets, L.N.; Makarenko, I.N.; Shapiro, A.Y.; Uvarova, T.G. [Institute of Crystallography, Moscow 117333 (Russian Federation)

    1995-06-01

    The normal-state transverse magnetoresistance ({Delta}{ital R}/{ital R}{sub 0}) has been studied in the {ital ab} plane of three YBa{sub 2}Cu{sub 3}O{sub {ital x}} single crystals with oxygen indices {ital x}=6.95, 6.88, and 6.62. A linear quadratic-field dependence {Delta}{ital R}/{ital R}{sub 0}={ital AH}{sup 2}+{ital BH} has been found up to 15 T in the temperature region where superconducting fluctuations are negligible. The linear component dominating in oxygen-deficient samples is probably related to the interaction between charge carriers and dynamic antiferromagnetic spin fluctuations in CuO{sub 2} layers of YBa{sub 2}Cu{sub 3}O{sub {ital x}}.

  2. Effects of Impurities Content (Oxygen, Carbon, Nitrogen) on Microstructure and Phase Transformation Temperatures of Near Equiatomic TiNi Shape Memory Alloys

    OpenAIRE

    Olier, P.; Barcelo, F.; Bechade, J.; Brachet, J; Lefevre, E.; Guenin, G.

    1997-01-01

    Investigation of precipitation is performed on several near equiatomic TiNi alloys elaborated by arc melting or by powder metallurgy (combustion synthesis mode). These alloys contain various amount of impurities (oxygen, carbon , nitrogen). We show that such impurities result in both oxides (Ti4Ni2Ox, with x ≤ 1) and carbonitrides (TiCxN1-x, with ≤ 1) precipitation. X-ray diffraction measurements are performed on residues of electrochemical extraction to determine the structure and the lattic...

  3. Muscle metabolism from near infrared spectroscopy during rhythmic handgrip in humans

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Pott, F; Madsen, P;

    1998-01-01

    with forearm oxygen uptake (VO2) [flow x (oxygen saturation in arnterial blood-oxygen saturation in venous blood, SaO2 - SvO2)], and with the 31P-magnetic resonance spectroscopy-determined ratio of inorganic phosphate to phosphocreatine (P(I):PCr). During ischaemia at rest, the fall in NIRS-O2 was more....... To conclude, NIRS-O2 of forearm flexor muscles closely reflected the exercise intensity and the metabolic rate determined by magnetic resonance spectroscopy but not that rate derived from flow and the arterio-venous oxygen difference....

  4. Fine temporal control of the medium gas content and acidity and on-chip generation of series of oxygen concentrations for cell cultures.

    Science.gov (United States)

    Polinkovsky, Mark; Gutierrez, Edgar; Levchenko, Andre; Groisman, Alex

    2009-04-21

    We describe the design, operation, and applications of two microfluidic devices that generate series of concentrations of oxygen, [O(2)], by on-chip gas mixing. Both devices are made of polydimethylsiloxane (PDMS) and have two layers of channels, the flow layer and the gas layer. By using in-situ measurements of [O(2)] with an oxygen-sensitive fluorescent dye, we show that gas diffusion through PDMS leads to equilibration of [O(2)] in an aqueous solution in the flow layer with [O(2)] in a gas injected into the gas layer on a time scale of approximately 1 sec. Injection of carbon dioxide into the gas layer causes the pH in the flow layer to drop within approximately 0.5 sec. Gas-mixing channel networks of both devices generate series of 9 gas mixtures with different [O(2)] from two gases fed to the inlets, thus creating regions with 9 different [O(2)] in the flow layer. The first device generates nitrogen-oxygen mixtures with [O(2)] varying linearly between 0 and 100%. The second device generates nitrogen-air mixtures with [O(2)] varying exponentially between 0 and 20.9%. The flow layers of the devices are designed for culturing bacteria in semi-permeable microchambers, and the second device is used to measure growth curves of E. coli colonies at 9 different [O(2)] in a single experiment. The cell division rates at [O(2)] of 0, 0.2, and 0.5% are found to be significantly different, further validating the capacity of the device to set [O(2)] in the flow layer with high precision and resolution. The degree of control of [O(2)] achieved in the devices and the robustness with respect to oxygen consumption due to respiration would be difficult to match in a traditional large-scale culture. The proposed devices and technology can be used in research on bacteria and yeast under microaerobic conditions and on mammalian cells under hypoxia.

  5. 激光在线分析系统在煤气氧含量检测中的应用%Application of laser on-line analyzing system in measurement of oxygen content in gas

    Institute of Scientific and Technical Information of China (English)

    魏爱国

    2013-01-01

    利用LGA-4130分析仪对电捕焦油器后煤气中的氧含量进行在线检测,并通过DCS控制系统设置含氧量的上限值对电捕焦油器实行连锁停机,确保电捕焦油器连续安全运行。对该系统进行分析后,在肯定其技术优点的同时指出其缺陷,并提出了改进建议。%Oxygen analyzer LGA-4130 is used for on-line measurement of oxygen content in gas after electro-static tar precipitator ( ETP ) and for interlock shutdown of the ETP in case of reaching the HH limit of the oxygen value preset on DCS aiming at a safe and stable running of the ETP .The ad-vantages and disadvantages of this analyzing system are studied in this paper ,suggestions for improve-ment are also given .

  6. Recycled oceanic crust and marine sediment in the source of alkali basalts in Shandong, eastern China: Evidence from magma water content and oxygen isotopes

    Science.gov (United States)

    Liu, Jia; Xia, Qun-Ke; Deloule, Etienne; Chen, Huan; Feng, Min

    2015-12-01

    The magma water contents and cpx δ18O values in alkali basalts from the Fuyanyshan (FYS) volcano in Shandong, eastern China, were investigated by an inverse calculation based on the water content of clinopyroxene (cpx) phenocrysts, the ivAlcpx-dependent water partitioning coefficient Dwatercpx>/melt, and secondary ion mass spectrometer, respectively. The calculated water content (H2O wt.) of magma ranges from 0.58% to 3.89%. It positively correlates with heavy rare earth element concentrations and bulk rock 87Sr/86Sr ratios, and it negatively correlates with Nb/U ratios. However, it is not correlated with bulk Mg# (Mg# = 100 × Mg / (Mg + Fe)) and (La/Yb)n (n represents primitive mantle normalization). Combined with the rather homogenous distribution of water content within cpx grains, these correlations indicate that the water variations among different samples represent the original magma signature, rather than results of a shallow process, such as degassing and diffusion. The δ18O of cpx phenocrysts varies from 3.6‰ to 6.3‰ (±0.5‰, 2SD), which may be best explained by the involvement of components from the lower and upper oceanic crust with marine sediments within the mantle source. The H2O/Ce ratios of the calculated melts range from 113 to 696 and form a positive trend with bulk rock 87Sr/86Sr, which cannot be explained by the recycled Sulu eclogite or by the metasomatized lithospheric mantle. Our modeling calculation shows that the decoupling of ɛHf and ɛNd could be caused by the involvement of marine sediments. Combing the high Ba/Th ratios, positive Sr spikes, and low Ce/Pb ratios for the Fuyanshan basalts, we suggest that the hydrous nature of the FYS basalts was derived from the hydrous mantle transition zone with ancient sediments.

  7. Cu含量对Ag-Cu钎料钎焊透氧膜界面结构的影响%Effect of Cu Content on Interface Microstructures of Oxygen-Permeable Membrane Brazed with Ag-Cu Brazing Filler

    Institute of Scientific and Technical Information of China (English)

    王方; 张玉文; 丁伟中; 鲁雄刚

    2011-01-01

    采用Ag-Cu钎料用于透氧膜与不锈钢支撑体之间的封接,研究了Cu含量对Ag-Cu钎料钎焊透氧膜界面结构的影响.利用SEM对连接界面的显微组织进行观察,并用EDS对界面的相组成进行分析.结果表明:纯Ag与透氧膜陶瓷之间的连接界面无元素互扩散;Ag中少量1 at%Cu的添加并未明显改善钎焊连接界面:当Cu含量增加到3.3 at%时,在透氧膜一侧生成一层由Cu和Ag扩散所致的厚度约200 μm的反应层,反应层的生成表明Ag-3.3Cu钎料与透氧膜之间具有良好的润湿性和界面结合.%Ag-Cu brazing filler were adopted to seal oxygen-permeable membrane ceramics and stainless steel support, and the effect of Cu content on interface microstructure of oxygen-permeable membrane brazed with Ag-Cu brazing filler was investigated. The microstructure of the interface was observed by SEM and the constituent phases were analyzed by EDS. The results show that no elemental interdiffusion occurs in the interface of pure Ag and oxygen-permeable membrane; the addition of 1 at%Cu doesn't improve the bonding of the interface obviously; when the Cu content reaches 3.3 at%, a reaction layer of about 200μrn in thickness forms on the membrane side due to the diffusion of Cu and Ag, which indicates the good wetting ability and interface bonding between Ag-3.3Cu brazing filler and oxygen-permeable membrane.

  8. Modification of the hydrophilic/hydrophobic characteristic of zein film surfaces by contact with oxygen plasma treated PDMS and oleic acid content.

    Science.gov (United States)

    Gezer, P Gizem; Brodsky, Serena; Hsiao, Austin; Liu, G Logan; Kokini, Jozef L

    2015-11-01

    Zein has been widely studied as a biopolymer due to its unique film-forming abilities. Surface properties are of high importance for certain applications which include microfluidics and tissue engineering, as they drastically affect the end result. It is important to develop techniques to modify zein surface properties without compromising bulk material properties. In this study, we developed a facile technique to change the water affinity of zein film surfaces, compatible with patterning techniques via soft lithography. This is achieved by a simple solvent casting technique onto a polydimethylsilohexane (PDMS) substrate that was exposed to oxygen plasma. Water contact angle measurements (WCA) were used to assess the hydrophillicity of zein surfaces and they reached as low as 20°. Atomic force microscopy, optical absorbance and light microscopy were used to study the characteristics of the film and its surface topography. Hydrophilic zein surfaces had higher roughness values compared to hydrophobic ones. Surface roughness, introduced by sandpaper and gratings does not have the same effect as surface chemistry. The amphiphilic nature of plasticizer oleic acid also contributed to the change in the water contact angle of the films. In conclusion, we demonstrated that zein film's surface properties can be controlled by its ability to self-assemble depending on the substrate that it is being cast on.

  9. Microstructure of MgB{sub 2} superconducting wire prepared by internal magnesium diffusion and in-situ powder-in-tube processes – Secondary phase intergrain nanolayers as an oxygen content indicator

    Energy Technology Data Exchange (ETDEWEB)

    Rosová, A., E-mail: alica.rosova@savba.sk; Kováč, P.; Hušek, I.; Brunner, B.; Dobročka, E.

    2015-09-15

    Highlights: • We compared microstructure of undoped MgB{sub 2} wires made by in-situ PIT and IMD. • The main differences were in MgB{sub 2} density and volume ratio of amorphous MgO. • Thin oriented layers of secondary phases were observed between MgB{sub 2} plate grains. • Only MgO or only Mg oriented layers were in the PIT or IMD samples, resp. • High MgB{sub 2} density and low MgO{sub 2} content caused higher J{sub c} of IMD wire. - Abstract: We analyzed microstructure of two undoped MgB{sub 2} single core wires prepared by two different technologies – in-situ powder-in-tube (PIT) technology and internal magnesium diffusion (IMD) processes. Their microstructure showed mainly different densities of superconducting material, corresponding content of pores and the volume ratio of amorphous MgO phase. We observed a special microstructural feature – thin oriented secondary phase layers on grain boundaries of plate-shaped MgB{sub 2} grains. The significant decrease of oxygen content in IMD wire was reflected in the presence of thin oriented Mg layers while in PIT wire thin oriented MgO layers were observed. The microstructure difference is reflected in increased critical current density J{sub c} of the IMD wire in comparison to the PIT one.

  10. Using oxygen at home

    Science.gov (United States)

    Oxygen - home use; COPD - home oxygen; Chronic obstructive airways disease - home oxygen; Chronic obstructive lung disease - home oxygen; Chronic bronchitis - home oxygen; Emphysema - home oxygen; Chronic respiratory ...

  11. 人造血管动静脉内瘘穿刺的护理体会%Nursing Care on Puncture of Arterio-Venous Fistula Replanted by Artificial Blood Vessel

    Institute of Scientific and Technical Information of China (English)

    于梅; 姚春英; 李圣梅

    2008-01-01

    目的 探讨人造血管动静脉内瘘的护理对策.方法 从2007年2月-2008年5月,对1例行人造血管动静脉内瘘的患者进行血液透析时穿刺的护理.结果 本例患者术后4个月开始应用,进行血液透析172次,其中成功穿刺170次,成功率达98.83%.结论 正确的进行人造血管内瘘穿刺可提高穿刺的成功率,良好的护理可延长人造血管的使用寿命.

  12. Oxygen isotopes and volatile contents of the Gorgona komatiites, Colombia: A confirmation of the deep mantle origin of H2O

    Science.gov (United States)

    Gurenko, Andrey A.; Kamenetsky, Vadim S.; Kerr, Andrew C.

    2016-11-01

    We report O isotopes in olivine grains (Fo89-93) and volatile contents (CO2, H2O, F, S, Cl) in olivine-hosted melt inclusions from one Gorgona picrite and five komatiites with the aim of constraining the origin of H2O in these magmas. These samples have previously been analysed for major and trace elements and volatile concentrations (H2O, S, Cl) and B isotopes in melt inclusions. A distinctive feature of the included melts is relatively high contents of volatile components and boron, which show positive anomalies in, otherwise depleted, primitive mantle normalised trace and rare earth element patterns and range in δ11 B from -11.5 to 15.6‰. In this study, the olivines were systematically analysed for O isotopes (1) in the centre of grains, (2) near the grain boundaries and, (3) as close as possible to the studied melt inclusions. The majority of olivines (∼66%) are "mantle"-like, 4.8 ‰ ≤δ18 O ≤ 5.5 ‰, with a subordinate but still significant number (∼33%) above, and only 2 grains below, this range. There is no systematic difference between the central and marginal parts of the grains. Higher than "mantle" δ18OOl values are ascribed to low-T (<300 °C) serpentinisation along inner fractures and grain boundaries of olivine phenocrysts. The measured concentrations of volatile components in the melt inclusions corrected for the effects of post-entrapment crystallisation and H2O-CO2 exsolution in inclusion shrinkage bubbles are: 286-1748 μg/g CO2, 0.2-0.86 wt.% H2O, 48-82 μg/g F, 398-699 μg/g S and 132-198 μg/g Cl. They correspond to a pressure of 86 ± 44MPa or ∼2.5-km crustal depth of olivine crystallisation. The correlations of S and, to a lesser extent, of H2O, with highly incompatible lithophile elements and the correlation of F with Cl, but no relationships of H2O with Cl, rule out shallow depth magma degassing and/or crustal contamination. Our new δ18 O olivine and volatile component data combined with the existing, highly variable δ11 B

  13. 体能快速恢复舱恢复过程中肌氧变化特征分析%Characteristic analysis of changes in muscle oxygen content during recovery process using rapid recovery cabin for physical fitness

    Institute of Scientific and Technical Information of China (English)

    陈万; 田诗彬; 张晓辉; 刘振宇; 黄超; 李岳

    2014-01-01

    Objective:To study characteristics of changes in muscle oxygen content and relevance of feature index during recovery process using different recovery modes after the same training-to-fa-tigue program,and to investigate the fast effect of recovery from sports fatigue by rapid recovery cab-in( RRC)for physical fitness with leg negative-normal pressures. Methods:Athletes trained to fa-tigue by the same training -to -fatigue program,then immediately to be assigned randomly to 3 groups using 3 different recovery modes including RRC(30 min),traditional recovery( TR)(15 min jogging+15 min massage)and spontaneous recovery( SR)(30 min static rest). Real time pa-rameters in muscle oxygen content of vastus lateralis were monitored and recorded by near-infrared spectroscopy,and recovery amplitude of muscle oxygen content(H),half recovery time(TR),half recovery rate( RHbO2 )were calculated and analyzed. Rate of perceived exertion( RPE)and heart rate( HR)were also recorded and analyzed. Results:1 )From 5 to 10 min of 30 min recovery process,the increment of muscle oxygenated hemoglobin concentration(ΔCHbO2 )of athletes in RRC showed an increasing trend. At 10 min,theΔCHbO2 of athletes in RRC was significantly high-er than that of SR group( P0. 05). 2)Following 10min,both ΔCHbO2 in RRC and TR groups were respectively higher than that of SR group( P0.05)。2)恢复过程后期肌氧的变化:进舱恢复组的恢复效果与传统恢复组基本相同,且明显好于自然恢复组(P <0.01)。3)恢复后即刻相关指标变化:心率和主观疲劳感觉无明显差异。结论:1)在恢复初期,快速恢复舱这种早期的快速恢复肌肉氧含量的优势可以较好地运用于实战比赛,如举重等的短时间休息间隙。2)体能快速恢复恢复舱在整个恢复过程中具有加速血液和淋巴系统循环,改善毛细血管功能,促进肌氧含量快速恢复的作用,为运动员的体能快速恢复提供了一

  14. [Apneic oxygenation].

    Science.gov (United States)

    Alekseev, A V; Vyzhigina, M A; Parshin, V D; Fedorov, D S

    2013-01-01

    Recent technological advances in thoracic and tracheal surgery make the anaesthesiologist use different respiratory techniques during the operation. Apneic oxygenation is a one of alternative techniques. This method is relatively easy in use, does not require special expensive equipment and is the only possible technique in several clinical situations when other respiratory methods are undesirable or cannot be used. However there is no enough information about apneic oxygenation in Russian. This article reviews publications about apneic oxygenation. The review deals with experiments on diffusion respiration in animals, physiological changes during apneic oxygenation in man and defines clinical cases when apneic oxygenation can be used.

  15. Effect of Surface Oxygen Content of Carbon Black on Electrical Properties of HDPE-Carbon Black Composites%炭黑表面含氧量对HDPE—CB复合物导电性能的影响

    Institute of Scientific and Technical Information of China (English)

    潘镱; 吴国章

    2012-01-01

    Carbon black (CB) was oxidized by HNO3 and the surface oxygen content (molar ratio of oxy gen to carbon) of CB increased from 1.0%(CB1) to 7.0%(CB2). Using CB1 and CB2 as fillers, high-den- sity polyethylene(HDPE) as matrix, two conductive composites were prepared. With higher surface oxy- gen content of CB, the percolation threshold of filled HDPE composites was lower, which was on contrary to that of carbon particles filled polar polymer composites of CB2. The dispersion and agglomeration beha- viors of CB1 and CB2 in HDPE were analyzed by scanning electron micrography, dynamic percolation effect and Payne effect. Results showed that CB2 particles dispersed more unevenly and agglomerated to form conductive networks more easily in HDPE matrix. The ability of CB agglomerate to form conductive networks in HDPE melt increased with the increasing of the surface oxygen content of CB particles.%通过硝酸氧化处理炭黑(CB),使其表面含氧量(氧元素与碳元素的摩尔百分比)由1.0%(CB1)提高到7.0%(CB2)。分别以CB1和CB2为填料,以高密度聚乙烯(HDPE)为基体,制备了两种导电复合材料。与碳粒子填充极性聚合物相反,表面含氧量高的CB2填充HDPE复合物的渗流阈值低。采用SEM、动态电渗流效应和Payne效应分析了两种炭黑在HDPE中的分散和凝聚特征。结果表明:CB2在HDPE中分散更不均匀,更容易凝聚形成网络。炭黑在非极性HDPE中凝聚形成导电网络的能力随炭黑表面含氧量的增加而提高。

  16. The Oxygen Cycle.

    Science.gov (United States)

    Swant, Gary D.

    Produced for primary grades, this booklet provides study of the oxygen-carbon dioxide cycle in nature. Line drawings, a minimum amount of narrative, and a glossary of terms make up its content. The booklet is designed to be used as reading material, a coloring book, or for dramatic arts with students acting out parts of the cycle. This work was…

  17. Oxygen Therapy

    OpenAIRE

    2000-01-01

    LTOT is prescribed for people with chronic lung disease in whom there is a decrease in the ability of the lungs to supply enough oxygen to the body. The heart is obliged to pump faster to meet the body's oxygen requirements. This may place undue stress on the heart, resulting in palpitations, dizziness and fatigue. A low oxygen level in arterial blood is also harmful to the heart, the brain and the pulmonary blood vessels. Oxygen therapy is used to break this cycle. A person with low blood ox...

  18. 冷射流方法脱除单重态氧气流中的水汽%Removal of water vapor content in singlet oxygen flow using cold-jet method

    Institute of Scientific and Technical Information of China (English)

    邓列征; 石文波; 杜姝彦; 杨何平; 沙国河; 张存浩

    2012-01-01

    为提高化学氧碘激光性能,分别使用-117 ℃乙醇、- 110℃氟里昂和-45 ℃质量分数为50%过氧化氢冷射流进行单重态氧气流中的水汽脱除实验.实验结果表明:这3种冷射流的除水效果并不显著,乙醇基本上没有任何脱水效果,氟里昂和过氧化氢仅可以将水汽含量分别降低至原来的约1/5和1/4;乙醇和氟里昂因极易挥发而对气流产生严重干扰,并不适合用于除水;只有难挥发的过氧化氢才是合适的候选.%To improve the performances of chemical oxygen iodine laser (COIL). experiments were done for the removal of water vapor content in singlet oxygen gas flows by using — 117 C ethanol (C2H5OH). — 110 C freon (CCl3F) and —45 C 50%. hydrogen peroxide (H2O2) cold jets respectively. Experimental results show that dehydration effects of the three cold jets are not so remarkable: C2H5OH has scarcely any dehydration effect, and CCl3 F and H3.( )2 can only reduce water vapor contents to about 1/5 and 1/4 of the initial values respectively. C2H5OH and CC13 F are so readily volatilized that they would produce severe interference in the gas flows and are not applicable to the removal of water vapor. Only the nonvolatile H2()2 is the suitable candidate.

  19. The natural history of oxygen.

    Science.gov (United States)

    Dole, M

    1965-09-01

    The nuclear reactions occurring in the cores of stars which are believed to produce the element oxygen are first described. Evidence for the absence of free oxygen in the early atmosphere of the earth is reviewed. Mechanisms of creation of atmospheric oxygen by photochemical processes are then discussed in detail. Uncertainty regarding the rate of diffusion of water vapor through the cold trap at 70 km altitude in calculating the rate of the photochemical production of oxygen is avoided by using data for the concentration of hydrogen atoms at 90 km obtained from the Meinel OH absorption bands. It is estimated that the present atmospheric oxygen content could have been produced five to ten times during the earth's history. It is shown that the isotopic composition of atmospheric oxygen is not that of photosynthetic oxygen. The fractionation of oxygen isotopes by organic respiration and oxidation occurs in a direction to enhance the O(18) content of the atmosphere and compensates for the O(18) dilution resulting from photosynthetic oxygen. Thus, an oxygen isotope cycle exists in nature.

  20. Appreciating Oxygen

    Science.gov (United States)

    Weiss, Hilton M.

    2008-01-01

    Photosynthetic flora and microfauna utilize light from the sun to convert carbon dioxide and water into carbohydrates and oxygen. While these carbohydrates and their derivative hydrocarbons are generally considered to be fuels, it is the thermodynamically energetic oxygen molecule that traps, stores, and provides almost all of the energy that…

  1. Comparative study on the effects of chlorite oxygen reaction product TCDO (tetrachlorodecaoxygen) and sodium chlorite solution (NaClO2) with equimolar chlorite content on bone marrow and peripheral blood of BDIX rats.

    Science.gov (United States)

    Kempf, S R; Blaszkiewitz, K; Reim, M; Ivankovic, S

    1993-01-01

    The effects of the chlorite-oxygen reaction product TCDO (tetrachlorodecaoxygen, active ingredient of the systemic application form of WF 10) were investigated on bone marrow and peripheral blood of BDIX rats in comparison to a sodium chlorite solution with a chlorite content identical to that of WF 10. Despite difficulties in determining the chemical differences between TCDO and a sodium chlorite solution, their differing effects on cells, tissue and organism were striking. The following characteristics have been observed: Stimulation of the bone marrow, evidenced by the pronounced increase in mature granulocytes, pronormo- and normoblasts, or increased cell proliferation rate, determined by means of the BrdUrd method, was achieved only with WF 10 (TCDO). Stimulation of the bone marrow led in turn to increased numbers of leucocytes and monocytes in the peripheral blood. In addition, WF 10 induced the production of large granular lymphocytes (LGLs), referred to as natural killer cells (NK-cells). In contrast, NaClO2 solution suppressed bone marrow function, exhibiting a toxic effect when given on a long-term basis. At the same time the number of mature granulocytes as well as pronormo- and normoblasts decreased, while the presence of LGLs was not observed. The results showed that TCDO is a potent stimulator of the bone marrow function and an effective modulator of the entire immune system. The toxic effect of chlorite, derived from the TCDO matrix, is not noticeable, being completely compensated by the favourable effects of TCDO.

  2. Evaluation of a pilot-scale sewage biogas powered 2.8 kWe Solid Oxide Fuel Cell: Assessment of heat-to-power ratio and influence of oxygen content

    Science.gov (United States)

    de Arespacochaga, N.; Valderrama, C.; Peregrina, C.; Mesa, C.; Bouchy, L.; Cortina, J. L.

    2015-12-01

    Biogas from anaerobic digestion of organic matter is a promising renewable energy source and fuel cells appear as a breakthrough technology to improve the performance of the biogas-to-energy valorisation chain. The vast majority of studies addressing biogas energy recovery through Solid Oxide Fuel Cells published in recent years correspond to simulations and lab-scale performance with synthetic biogas. This paper assesses the pilot performance of a 2.8 kWe SOFC unit powered with cleaned sewage biogas for around 700 h in a Wastewater Treatment Plant. The biogas thorough treatment consisting of a biological desulphurisation with a biotrickling filter followed by a deep cleaning step based on adsorption is successful for removing sulphur compounds, siloxanes and hydrocarbons. The influence of the heat-to-power ratio on fuel cell performance is investigated operating the system at O/C ratio of 2, reforming temperature of 550 °C, stack temperature of 800 °C and at a constant voltage of 43 V. At optimized conditions for electrical production satisfying heat demand in the WWTP, system electrical and thermal efficiencies account for 34% and 28%. Cogeneration efficiency remains constant at around 59-62% for all the heat-to-power ratios tested. Furthermore, the impact of the oxygen content in the biogas is also studied.

  3. [Nitrogenase, hydrogenase and nitrate reductase activities, oxygen consumption, and ATP content in nodules formed by strains of Rhizobium leguminosarum 128C53 and 300 in symbiosis with pea plants].

    Science.gov (United States)

    Bedmar, E J; Olivares, J

    1986-10-01

    The nitrogenase activity, nitrate reductase activity and oxygen uptake as well as the hydrogen incorporation and ATP content were examined in the root nodules and bacteroids, respectively, formed by Rhizobium leguminosarum strains 128C53 (hydrogenase positive) and 300 (hydrogenase negative) in symbiosis with Pisum sativum plants grown in the presence of 2 mM KNO3. The strain 128C53 showed the greatest values for all parameters analyzed, except for the nitrate reductase activity, which was higher for the strain 300. Similarly, nodule nitrate reductase activity in strain 300 was greater than that in strain 128C53 when plants grew in the absence of combined nitrogen. In general, the highest values were obtained when determinations were made after 7 hours of plant illumination. However, the hydrogenase activity of strain 128C53 and the nitrate reductase activities of both strains increased with the light period, reaching a maximum after 14 hours of illumination. These results suggest that the benefits derived from the superior symbiotic properties and from the presence of hydrogenase activity in strain 128C53 could be counteracted by the higher rates of the nodule nitrate reductase activity in strain 300.

  4. Preparation of low-platinum-content platinum-nickel, platinum-cobalt binary alloy and platinum-nickel-cobalt ternary alloy catalysts for oxygen reduction reaction in polymer electrolyte fuel cells

    Science.gov (United States)

    Li, Mu; Lei, Yanhua; Sheng, Nan; Ohtsuka, Toshiaki

    2015-10-01

    A series of low-platinum-content platinum-nickel (Pt-Ni), platinum-cobalt (Pt-Co) binary alloys and platinum-nickel-cobalt (Pt-Ni-Co) ternary alloys electrocatalysts were successfully prepared by a three-step process based on electrodeposition technique and studied as electrocatalysts for oxygen reduction reaction (ORR) in polymer-electrolyte fuel cells. Kinetics of ORR was studied in 0.5 M H2SO4 solution on the Pt-Ni, Pt-Co and Pt-Ni-Co alloys catalysts using rotating disk electrode technique. Both the series of Pt-Ni, Pt-Co binary alloys and the Pt-Ni-Co ternary alloys catalysts exhibited an obvious enhancement of ORR activity in comparison with pure Pt. The significant promotion of ORR activities of Pt-Ni and Pt-Co binary alloys was attributed to the enhancement of the first electron-transfer step, whereas, Pt-Ni-Co ternary alloys presented a more complicated mechanism during the electrocatalysis process but a much more efficient ORR activities than the binary alloys.

  5. Synthesis, structure and characterization of neutral coordination polymers of 5,5'-bistetrazole with copper(ii), zinc(ii) and cadmium(ii): a new route to reconcile oxygen balance and nitrogen content of high-energy MOFs.

    Science.gov (United States)

    Chen, Sitong; Zhang, Bo; Yang, Li; Wang, Lin; Zhang, Tonglai

    2016-11-14

    Hydrothermal reactions of Cu(ii)/Zn(ii)/Cd(ii) with 5,5'-bistetrazole (H2BT) lead to three new energetic coordination polymers: [CuBT(H2O)]n (1), [ZnBT(H2O)2]n (2), and [CdBT(H2O)2]n (3). These crystal structures were determined by single X-ray diffraction. Compound 1 forms regular and compact 3-D frameworks and compounds 2-3 are 1-D chain structures. These compounds show prominent thermostability (Tdec = 349.1 °C for 1, 334.8 °C for 2, and 394.2 °C for 3) investigated by using differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Sensitivities towards impact and friction were measured. Compound 1 is sensitive to both impact and friction (100% explosion under the test conditions), while compounds 2-3 are sensitive to neither (0% explosion under the test conditions). The heats of detonation (ΔHdet) of 1-3 were calculated based on density functional theory (DFT). Compound 1 possesses the highest calculated ΔHdet (26.7267 kJ g(-1)) among the reported energetic MOFs. Moreover, compared with the reported energetic MOFs, compound 1 also has a good balance of high nitrogen content (51.46%) and high oxygen balance (-36.76%) as well as a very high crystal density of 2.505 g cm(-3).

  6. Experimental Study on Influence of Oxygen Content on the Composition of Biomass Gasification Syngas and Tar%氧气对生物质气化气及焦油成分影响的实验研究

    Institute of Scientific and Technical Information of China (English)

    刘春元; 罗永浩

    2014-01-01

    Biomass gasification for reburning is one kind of the most promising ways of biomass utilization.Different composition of syngas and tar will influence the NO reduction effect in the process of biomass gasification for reburning.A 10 kW updraft biomass gasifier was designed and built,and experiments on wood gasification were carried out to study the effect of oxygen content on the composition of syngas and tar.The relative content of the main gas species in the syngas rises with the air flow rate increase,but the relative content of phenolic compounds,which share a large part in the tar,declines with the air flow rate increase according to the experimental results. The study provides a theoretical guidance for the development of technology of biomass gasification for reburning.%生物质气化再燃是生物质能利用的较好方式之一。生物质气化再燃技术中,气化气及焦油的不同组成对再燃效果有所影响。自行设计搭建热功率为10 kW的上吸式生物质气化炉,进行典型生物质燃料木屑的气化实验,通过改变气化剂空气的量,研究氧气对生物质气化气及焦油成分的影响。实验结果表明,氧气量增加,气化气中主要组分的体积含量均有所增加,而焦油中占据主要比重的酚类物质相对含量减少。此研究为生物质气化再燃技术的开发提供一定的理论指导。

  7. 小儿体外膜肺氧合支持治疗8例%A case series of 8 children supported with extracorporeal membrane oxygenation

    Institute of Scientific and Technical Information of China (English)

    傅惟定; 张蔚; 王伟; 姜磊; 沈佳; 唐嘉忠; 朱德明

    2011-01-01

    kilogram body weight. Results Five patients died, with a mortality of 62.5%, and 3 cases discharged, with a survival rate of 38%. Bleeding occurred in 5 cases, thrombosis occurred in 2 cases, hemolysis was identified in 1 case and DIC was observed in 1 case.One case had liver failure and 2 cases had malnutrition. Oxygenator plasma leakage occurred in 2 cases. Mean arterial blood pressure increased significantly after the establishment of ECMO as compared with that before the procedure [( 60.2 ± 7.8 )mmHg vs. (48. 1 ± 5.2 ) mmHg, P≤0.05]. The arterial concentration of lactate decreased significantly, from (5. 1 ± 0. 8 )mmol per liter before ECMO to ( 3.6 ±0. 5 )mmol per liter after ECMO, P <0.05. Conclusion For patients who survived the congenital heart surgery and no residual anatomic deformity, ECMO can be used as early as possible as a treatment for severe heart failure which resulted from coexistent of left and right ventricular and pulmonary insufficiency. An overall mortality may be decreased by ECMO technique as it plays a substitution role for gas exchange in the lung. As a result, the concentration of oxygen and the airway pressure used during ventilation, and the resultant lung injury can be reduced. Appropriate strategies involve transfusion of fresh platelet and packed red blood cells, replacement of frozen plasma and blood products, as well as rational use of vasoactive drugs and heparin, and maintaining a stable internal environment. Following strategies are also recommended: using continuous arterio-venous hemofiltration and durable heparin-coated membrne oxygenator, reducing hemorrhagic complications, monitoring pressure on both side of the film, identifying plasma leakage carefully and reducing the mechanical complications.

  8. Oxygen Therapy

    Science.gov (United States)

    ... oxygen at very high altitudes (like in the mountains or in an airplane) even if you do ... Med Vol 171. P1-P2, 2005 ATS Patient Education Series © 2016 American Thoracic Society www. thoracic. org ...

  9. Dissolved oxygen

    National Research Council Canada - National Science Library

    1981-01-01

    Dissolved oxygen concentrations in the waters of Botany Bay and Georges and Cooks Rivers vary mainly as a result of tidal water movements, algal and macrophytic growth and decay, and effects of storms...

  10. High frequency jet ventilation in acute respiratory failure: which ventilator settings?

    Science.gov (United States)

    Mal, H; Rouby, J J; Benhamou, D; Viars, P

    1986-01-01

    Seven hypoxaemic patients with acute respiratory failure were ventilated with HFJV (Ventilator VS 600). Arterial oxygenation was improved in each patient by the increases induced in mean airway pressure (PAW) (to 20 cm H2O) using three different ventilatory settings applied in a random order: technique A: I:E ratio 0.43, driving pressure 2.9 bar, no PEEP; technique B: I:E ratio 1.0, driving pressure 1.9 bar, no PEEP; technique C: I:E ratio 0.43, driving pressure 1.8 bar, PEEP 11 cm H2O. Respiratory frequency was maintained at 250 b.p.m. throughout the study. There were no significant differences in PaO2 (FlO2 = 1) or Qs/Qt between the three techniques. In contrast, carbon dioxide elimination was markedly affected by the method used to increase PAW:PaCO2 was significantly higher during technique C (8.5 +/- 3.6 kPa) and technique B (6.6 +/- 2.1 kPa) than during technique A (4.8 +/- 0.9 kPa). Significant increases in cardiac index, heartrate, mean pulmonary arterial pressure and a decrease in the arterio-venous oxygen content difference were observed when PaCO2 increased. We conclude that, to obtain the PAW necessary to improve pulmonary oxygen exchange, more effective carbon dioxide elimination is achieved by increasing the driving pressure, rather than by increasing the I:E ratio, or using a PEEP valve.

  11. Effects of oxygen content and processing method on microstructure and mechanical properties of biomedical Ti-6AI-4V titanium alloy wire%氧含量及加工方法对医用Ti-6Al-4V钛合金丝组织与性能的影响

    Institute of Scientific and Technical Information of China (English)

    樊亚军; 曹继敏; 杨华斌; 李雷; 罗斌莉

    2012-01-01

    Ti-6Al-4V titanium alloys with different oxygen contents were prepared to 61. 0 mm, 62.0 mm, 62. 5 mm wires by temperature controlled drawing. Effects of oxygen content and temperature controlled drawing on microstrueture and mechanical properties of the alloy were investigated. The results show that the higher oxygen content, the more α phase. 85% α phase can be obtained when oxygen content is 0.19%. The equiaxed α phase grain size in as-rolled 68.0 mm Ti-6Al-4V alloy rod is 2-5 μm, and 0.3 μm ultra-fine grain can be obtained by drawing to 61.0 mm. With the increase of oxygen content in the alloy and drawing diameter decreasing, wire strength improves and plasticity decreases. Tensile strength and elongation of the Ti-6Al-4V alloy wire of 62. 0 mm with 0.14% oxygen content is 1270 MPa and 12% respectively, and comprehensive mechanical properties are excellent.%对不同氧含量的Ti-6A1-4V钛合金采用控温热拉拔,制得Ф1.0mm、Ф2.0mm、Ф2.5mm3种不同规格的丝材,研究Ti-6A1α-4V钛合金中氧含量及控温热拉拔制备方法对材料组织和力学性能的影响。结果表明,氧含量越高,合金中相的相对含量越多,氧含量0.19%时,可获得α相含量85%的微观组织;Ф8.0mm轧制坯料等轴α相尺寸为2~5μm,拉拔成4,1.0mm后获得约0.3μm的超细晶粒;随着合金中氧含量的增加,拉拔直径变细,丝材强度提高,塑性下降;0.14%氧含量Ti-6Al-4V4Ф2.0mm丝材抗拉强度和塑性分别达到1270MPa和12%,综合力学性能优良。

  12. Study on Oxygen Content Control Technology About Pring Steel 60 Si2 MnA in Ma Steel EAF%马钢电弧炉弹簧钢60 Si2 MnA氧含量技术可行性研究

    Institute of Scientific and Technical Information of China (English)

    崔晓梅

    2015-01-01

    Based on the smelting process of the EAF → LF → RH for 60Si2MnA spring steel of Ma Steel electric furnace the evolvement about full of oxygen in the the spring steel smelting process and impact factors, the same time, the distribution of of spring steel non -metallic inclusions, sources, and control system analysis, the following conclusions:In the electric arc furnace-LF the re-fining-RH vacuum treatment, the total oxygen content is substantially decreased gradually.By refi-ning the whole bottom blowing argon,,the top slag operation and high alkalinity ( R=3.5 ) refining slag,to reduce the oxide content of the slag and activity are conducive to reducing the total oxygen con-tent of spring steel.The oxygen content in steel can be controlled at less than 10ppm.%针对马钢100t电弧炉EAF→LF→RH生产弹簧钢60Si2MnA的冶炼生产工艺流程,采取系统的取样、综合分析弹簧钢冶炼过程中全氧变化规律及影响因素,结果表明:在电弧炉-LF精炼-RH真空处理中,全氧含量基本是逐渐降低的;通过精炼全程底吹氩气,采用顶渣操作和高碱度(R=3.5)精炼渣,来降低渣中氧化物的含量及活度,均有利于降低弹簧钢中的全氧含量;钢水中氧含量最终可以控制在10ppm以内。

  13. Reversible Oxygenation of Oxygen Transport Proteins.

    Science.gov (United States)

    Drain, C. M.; Corden, Barry B.

    1987-01-01

    Describes a lecture demonstration which illustrates changes in the visible spectra of oxygen transport proteins upon reversible oxygen binding. Provides a comparison of the physical characteristics of oxygen storage and transport proteins. Reviews essentials for preparation of the materials. (ML)

  14. The generation of oxygen radicals after drinking of oxygenated water.

    Science.gov (United States)

    Schoenberg, M H; Hierl, T C; Zhao, J; Wohlgemuth, N; Nilsson, U A

    2002-03-28

    It has been speculated whether ingestion of oxygenated water can lead to an enhanced generation of oxygen radicals. The purpose of three prospective randomized blinded clinical studies was therefore to measure if, when and at which oxygen content in the water,drinking of oxygenated water induces the generation of radicals. Moreover in the fourth prospective,randomized, blinded study possible longterm effects of drinking oxygenated water were examined. Altogether 66 volunteers were drinking 300 ml oxygenated or tap water within 15 minutes. Before drinking, altogether 15 ml of blood from the antecubital vein was collected for determination of ascorbyl radicals with ESR, routine laboratory data (hemoglobin, erythrocytes, hematocrit, leukocytes, thrombocytes, uric acid) and the vitamins A,C,E by HPLC. After drinking the ascorbyl radical measurements were repeated from blood of the antecubital vein. In the longterm study ( fourth study) the volunteers had to undergo the same procedure, as described above, at day 1 and day 21. In the meantime they were drinking per day three times 300 ml either oxygenated water or tap water. All subjects exhibited normal vitamin levels in all three studies. Concommitantly in the fourth study there was no statistically relevant alteration of vitamin concentrations during the observation period of three weeks in the verum and placebo-group. 30 minutes after drinking oxygenated water the concentration of ascorbyl radicals increased significantly by median 42 % from median 48 to 65 nmol/l. This increase of ascorbyl radicals after 30 minutes was reproducible in all studies. The levels of ascorbyl radicals remained elevated for 60 minutes after drinking and returned to normal after 120 minutes. This increase was independent of the oxygen concentration in the water, beginning at 30 mg oxygen/l. Water containing 15 mg oxygen/l did not lead to an enhanced radical formation. Longterm consumption of oxygenated water attenuated the ascorbyl radical

  15. Microstructure and high temperature cyclic oxidation in atmospheres with variable oxygen contents of plasma and HVOF NiCrBSiFe sprayed coatings; Microestructura y oxidacion ciclica en atmosferas con contenidos de oxigeno variables de un recubrimiento NiCrBSiFe proyectado termicamente por plasma y HVOF

    Energy Technology Data Exchange (ETDEWEB)

    Higuera-Hidalgo, V.; Belzunce-Varela, F. J.; Riba-Lopez, J.

    2006-07-01

    The influence of thermal spraying procedure (plasma and HVOF) on the microstructure, high temperature oxidation resistance and adherence of NiCrSiFe coatings has been examined. Two different series of oxidation tests have been carried out in air (21% oxygen) at 800 and 1,000 degree centigree (1,073 y 1,273 K) and in a simulated gas turbine environment (10% oxygen) representative of a combined-cycle power generation plant, at the same temperatures. Coating microstructure, porosity, oxide content and microhardness are highly dependent on the spraying procedure and coating hardness also significantly decreases after long maintenance at high temperature (1,000 degree centigree). Finally, the oxidation weight gain and the adherence of NiCrBSiFe coatings are also dependent on the morphology of the coating but, nevertheless, the oxidation behaviour of these coatings was very good as protective chromium and silicon oxides were always formed. (Author) 14 refs.

  16. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben;

    2010-01-01

    The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein and the mesen......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...... and the mesenteric artery and a flow probe around the portal vein to allow assessment of nutrient absorption using Fick's principle. In Exp. 1, six sows (mean LW = 202 ± 28 kg) were fed three diets containing 517, 216 or 225 g/kg DM of starch, respectively. In Exp. 2, six female pigs (mean LW = 59 ± 2 kg) were fed...... three different diets with similar contents of starch (470-506 g/kg DM). The diets in both studies differed regarding amount and solubility of fibre. Blood samples were collected repeatedly 0-10 h after morning feeding. Glucose was measured in whole blood using a glucometer (Accu-Chek®) and in plasma...

  17. 铝脱氧并真空脱气后喂钙-硅线对GCr5钢中氧含量及夹杂物的影响%Effect of Ca-Si Wire Feeding on Oxygen Content and Inclusion in AI-Deoxidized and Vacuum Degassed GCrl5 Steel

    Institute of Scientific and Technical Information of China (English)

    范植金; 冯文圣; 罗国华; 朱玉秀

    2011-01-01

    The effect of Ca-Si wire feeding on oxygen content and inclusion in Al-deoxidized and vacuum degassed CX2rl5 steel was investigated by oxygen content analysis, inclusions rating and electron probe observation. The results show that there was no further effect on oxygen content and D-type inclusion between Al-deoxidized and vacuum degassed GCr15 steel with Ca-Si wire feeding after LF and VD secondary refining and Al-deoxidized GCrl5 steel without Ca-Si wire feeding. The problem o{ nozzle clogging during continuous casting could be solved by feeding Ca-Si wire. Granular calcium-aluminates wrapped by a layer of calcium sulfide were formed in GCr15 steel treated by refining slag of CaO-SiO2-Al2O3.%对GCr15钢进行了氧含量分析、夹杂物评级和电子探针观察,研究了喂钙-硅线对铝脱氧并真空脱气后钢中氧含量及夹杂物的影响。结果表明:铝脱氧的GCr15钢经LF和VD炉真空脱气(精炼)后再喂钙-硅线,其氧含量和D类点状夹杂物级别与未喂钙一硅线的相比没有明显的差别;为解决连铸水口堵塞问题可喂钙一硅线;GCr15钢采用CaO-SiO2-Al2O3渣系精炼,可形成粒状铝酸钙夹杂物,其外表面常常吸附一层CaS。

  18. Oxygen measurements to improve singlet oxygen dosimetry

    Science.gov (United States)

    Kim, Michele M.; Penjweini, Rozhin; Ong, Yi Hong; Finlay, Jarod C.; Zhu, Timothy C.

    2017-02-01

    Photodynamic therapy (PDT) involves interactions between the three main components of light fluence, photosensitizer concentration, and oxygenation. Currently, singlet oxygen explicit dosimetry (SOED) has focused on the first two of these components. The macroscopic model to calculate reacted singlet oxygen has previously involved a fixed initial ground state oxygen concentration. A phosphorescence-based oxygen probe was used to measure ground state oxygen concentration throughout treatments for mice bearing radioactively induced fibroscarcoma tumors. Photofrin-, BPD-, and HPPH-mediated PDT was performed on mice. Model-calculated oxygen and measured oxygen was compared to evaluate the macroscopic model as well as the photochemical parameters involved. Oxygen measurements at various depths were compared to calculated values. Furthermore, we explored the use of noninvasive diffuse correlation spectroscopy (DCS) to measure tumor blood flow changes in response to PDT to improve the model calculation of reacted singlet oxygen. Mice were monitored after treatment to see the effect of oxygenation on long-term recurrence-free survival as well as the efficacy of using reacted singlet oxygen as a predictive measure of outcome. Measurement of oxygenation during treatment helps to improve SOED as well as confirm the photochemical parameters involved in the macroscopic model. Use of DCS in predicting oxygenation changes was also investigated.

  19. Carbon mineralization and oxygen dynamics in sediments with deep oxygen penetration, Lake Superior

    DEFF Research Database (Denmark)

    Li, Jiying; Crowe, Sean Andrew; Miklesh, David

    2012-01-01

    To understand carbon and oxygen dynamics in sediments with deep oxygen penetration, we investigated eight locations (160–318-m depth) throughout Lake Superior. Despite the 2–4 weight percent organic carbon content, oxygen penetrated into the sediment by 3.5 to > 12 cm at all locations. Such deep...... penetration is explained by low sedimentation rates (0.01–0.04 cm yr−1), high solubility of oxygen in freshwater, and a shallow (∼ 2 cm) bioturbation zone. In response mainly to oxygen variations in the bottom waters, the sediment oxygen penetration varied seasonally by as much as several centimeters......, suggesting that temporal variability in deeply oxygenated sediments may be greater than previously acknowledged. The oxygen uptake rates (4.4–7.7 mmol m−2 d−1, average 6.1 mmol m−2 d−1) and carbon mineralization efficiency (∼ 90% of deposited carbon) were similar to those in marine hemipelagic and pelagic...

  20. Cation composition and oxygen content dependence of crystal structure and T sub c for Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y

    CERN Document Server

    Idemoto, Y; Koura, N; Kamiyama, T; Oikawa, K; Izumi, F

    2003-01-01

    Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y (Tl-2223 system) superconducting oxides with various Tl contents and Cu contents were prepared. We investigated the relation between crystal structure and superconducting property dependence of Tl and Cu content. First, we obtained an almost single-phase material at a Tl content 2-x = 1.7 and the Tl-2223 phase remained the main phase in the region of 2 - x >= 0.631 of Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 O sub y. T sub c was about 120 K for the Tl-2223 in a wide range of 0.631 <= 2 - x <= 1.761. Second, we obtained a single-phase at 2 - x = 1.777 and Cu content 3 + z = 3.284 of Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y. The T sub c (zero) dependence of Cu/Tl ratio, showed a maximum value of 122 K at Cu/Tl ratio = 2.026. Based on results of crystal structure refinements by powder neutron diffraction, it was found that the change in bond length and angle dependence of average Cu valence were similar fo...

  1. 高铜铅精矿富氧底吹工业实践%Industrial Practice of Rich Oxygen Bottom Blowing Process of Smelting High Copper Content of Lead Concentrate

    Institute of Scientific and Technical Information of China (English)

    陈学兴; 欧阳坤

    2014-01-01

    A lead factory had smelted a batch of high copper content of lead concentrate , through two months of industrial practice , high copper content of lead concentrate had certain influence to the produc-tion of bottom blowing furnace and fuming furnace . The industrial test results showed that copper can be enriched in the crude lead and matte , the copper content of crude lead can reach more than 10 percent , the copper content of matte can reach more than 40 percent , the copper content of slag can be controlled under 0 .65 percent , and the recovery rate of copper can reach more than 90 percent .%某铅厂处理了一批高铜铅精矿,通过2个月的工业生产,入炉原料含铜高对底吹炉、烟化炉生产有一定影响,整个工业试验结果表明,铜可以在粗铅及锍中富集,粗铅含铜可达10%以上,锍含铜可达40%以上,弃渣含铜可控制在0.65%以下,铜的回收率可达90%。

  2. Oxygen requirements of the earliest animals

    Science.gov (United States)

    Mills, Daniel B.; Ward, Lewis M.; Jones, CarriAyne; Sweeten, Brittany; Forth, Michael; Treusch, Alexander H.; Canfield, Donald E.

    2014-03-01

    A rise in the oxygen content of the atmosphere and oceans is one of the most popular explanations for the relatively late and abrupt appearance of animal life on Earth. In this scenario, Earth's surface environment failed to meet the high oxygen requirements of animals up until the middle to late Neoproterozoic Era (850-542 million years ago), when oxygen concentrations sufficiently rose to permit the existence of animal life for the first time. Although multiple lines of geochemical evidence support an oxygenation of the Ediacaran oceans (635-542 million years ago), roughly corresponding with the first appearance of metazoans in the fossil record, the oxygen requirements of basal animals remain unclear. Here we show that modern demosponges, serving as analogs for early animals, can survive under low-oxygen conditions of 0.5-4.0% present atmospheric levels. Because the last common ancestor of metazoans likely exhibited a physiology and morphology similar to that of a modern sponge, its oxygen demands may have been met well before the enhanced oxygenation of the Ediacaran Period. Therefore, the origin of animals may not have been triggered by a contemporaneous rise in the oxygen content of the atmosphere and oceans. Instead, other ecological and developmental processes are needed to adequately explain the origin and earliest evolution of animal life on Earth.

  3. Impacts of Shisiwei Jianzhong Decoction on the Convulsion Latency and the Content of Cytokines in Brain Tissue of the Mice with Oxygen Convulsion%十四味建中汤对氧惊厥小鼠惊厥潜伏期及脑组织炎症细胞因子含量的影响

    Institute of Scientific and Technical Information of China (English)

    雷箴; 王国忠

    2015-01-01

    Objective To discuss the impacts and significance of shisiwei jianzhong decoction on convulsion latency and the content of IL - 1β and IL - 10 in brain tissue of the mice with oxygen convulsion. Methods Fifty - six mice were randomized into 7 groups,named an oxygen - convulsion 6 h group(6 h group),a 24 h group,a 48 h group,a shisiwei jianzhong decoction + oxygen - convulsion 6 h group(a therapy 6 h group),a therapy 24 h group,a therapy 48group and a normal control group. In all of the therapy groups, 2 weeks before convulsion induced by oxygen,shishiwei jianzhong decoction was used for gastric perfusion, once every day. The mice in all of the oxygen convulsion groups and the therapy groups were placed in 500 kPa oxygen environment till the seizure so as to prepare the model of oxygen convulsion. The enzyme - linked immunosorbent assay was used to detect the content of IL - 1β and IL - 10 in brain tissue. Results There was no significant difference in convulsion latency between the therapy groups and the oxygen convulsion groups(P ﹥ 0. 05). In the 24 h group and the 48 h group,the content of IL - 1β was higher significantly than that in the normal control group,indicating the significant difference(P ﹤ 0. 05),and that in the therapy 24 h group and the therapy 48 h group was lower significantly than that in the corresponding oxygen convulsion groups of the same time point,indicating the significant difference in the pair comparison(P ﹤ 0. 05). At the same time point,the difference in the content of IL - 10 was not significant among the oxygen convulsion groups,the therapy groups and the normal control group(P ﹥ 0. 05). Conclusion Shisiwei jianzhong decoc-tion does not significantly prolong the latency of oxygen convulsion in the mice,but it effectively reduces the content of IL - 1β,benefits the re - balance of proinflammatory cytokine and anti - inflammatory cytokine and alleviates the convulsive brain damage.%目的:探讨十四味建中汤对氧惊

  4. Facilitated oxygen transport in liquid membranes: review and new concepts

    NARCIS (Netherlands)

    Figoli, A.; Sager, W.F.C.; Mulder, M.H.V.

    2001-01-01

    In this paper, an overview is given on membranes with oxygen facilitated transport properties to enrich the oxygen content in air. Special emphasis is paid to recent developments of oxygen carrier systems and carrier containing membranes. Concepts leading to a structural evolution of supported liqui

  5. Auditory Risk of Exploding Hydrogen-Oxygen Balloons

    Science.gov (United States)

    Gee, Kent L.; Vernon, Julia A.; Macedone, Jeffrey H.

    2010-01-01

    Although hydrogen-oxygen balloon explosions are popular demonstrations, the acoustic impulse created poses a hearing damage risk if the peak level exceeds 140 dB at the listener's ear. The results of acoustical measurements of hydrogen-oxygen balloons of varying volume and oxygen content are described. It is shown that hydrogen balloons may be…

  6. Haemodynamic influences on kidney oxygenation : Clinical implications of integrative physiology

    NARCIS (Netherlands)

    Evans, Roger G.; Ince, Can; Joles, Jaap A.; Smith, David W.; May, Clive N.; O'Connor, Paul M.; Gardiner, Bruce S.

    2013-01-01

    Renal blood flow, local tissue perfusion and blood oxygen content are the major determinants of oxygen delivery to kidney tissue. Arterial pressure and segmental vascular resistance influence kidney oxygen consumption through effects on glomerular filtration rate and sodium reabsorption. Diffusive s

  7. Researching of electro tar precipitator used in biomass gas's cleaning and allowed highest oxygen content in the gas%电捕焦油器用于生物质燃气净化及燃气允许最高氧含量的研究

    Institute of Scientific and Technical Information of China (English)

    郭东彦; 伊晓路; 闫桂焕; 肖琪

    2012-01-01

    焦油清除是生物质气化技术的难点问题,用电捕焦油器除焦是解决焦油问题的根本途径.通过试验,验证了电捕焦油器应用于生物质燃气的效果;计算了典型生物质燃气的爆炸极限;提出了氧含量以1.5%为报警极限,最高允许氧含量不超过2%;建议修改相关标准,为电捕焦油器在生物质燃气领域的应用提供理论依据.%Tar precipitator is always a difficult technology in biomass gasification. It's the ultimate approach using electro tar precipitator to solve this problem. Through tests, it has verified the effect of electro tar precipitator in biomass gasification. The explosive limit of the typical gas has been calculated and it has been proposed the alarming limit is 1.5% oxygen content and the highest oxygen content allowed in the gas is 2%. Suggestion has been put forward to verify the concern standards to promote the use of the electro tar precipitator in biomass gasification.

  8. Oxygen requirements of the earliest animals

    DEFF Research Database (Denmark)

    Mills, Daniel Brady; Ward, Lewis M.; Jones, CarriAyne

    2014-01-01

    A rise in the oxygen content of the atmosphere and oceans is one of the most popular explanations for the relatively late and abrupt appearance of animal life on Earth. In this scenario, Earth's surface environment failed to meet the high oxygen requirements of animals up until the middle to late...... Neoproterozoic Era (850-542 million years ago), when oxygen concentrations sufficiently rose to permit the existence of animal life for the first time. Although multiple lines of geochemical evidence support an oxygenation of the Ediacaran oceans (635-542 million years ago), roughly corresponding with the first...... appearance of metazoans in the fossil record, the oxygen requirements of basal animals remain unclear. Here we show that modern demosponges, serving as analogs for early animals, can survive under low-oxygen conditions of 0.5-4.0% present atmospheric levels. Because the last common ancestor of metazoans...

  9. Cerebral oxygenation and hyperthermia

    Directory of Open Access Journals (Sweden)

    Anthony Richard Bain

    2014-03-01

    Full Text Available Hyperthermia is associated with marked reductions in cerebral blood flow (CBF. Increased distribution of cardiac output to the periphery, increases in alveolar ventilation and resultant hypocapnia each contribute to the fall in CBF during passive hyperthermia; however, their relative contribution remains a point of contention, and probably depends on the experimental condition (e.g. posture and degree of hyperthermia. The hyperthermia-induced hyperventilatory response reduces arterial CO2 pressure (PaCO2 causing cerebral vasoconstriction and subsequent reductions in flow. During supine passive hyperthermia, the majority of recent data indicate that reductions in PaCO2 may be the primary, if not sole, culprit for reduced CBF. On the other hand, during more dynamic conditions (e.g. hemorrhage or orthostatic challenges, an inability to appropriately decrease peripheral vascular conductance presents a condition whereby adequate cerebral perfusion pressure may be compromised secondary to reductions in systemic blood pressure. Although studies have reported maintenance of pre-frontal cortex oxygenation (assessed by near-infrared spectroscopy during exercise and severe heat stress, the influence of cutaneous blood flow is known to contaminate this measure. This review discusses the governing mechanisms associated with changes in CBF and oxygenation during moderate to severe (i.e. 1.0°C to 2.0°C increase in body core temperature levels of hyperthermia. Future research directions are provided.

  10. Oxygen and disorder effect in the magnetic properties of manganite films

    Energy Technology Data Exchange (ETDEWEB)

    Sirena, M. E-mail: sirenam@ib.cnea.gov.ar; Haberkorn, N.; Granada, M.; Steren, L.B.; Guimpel, J

    2004-05-01

    We have made a systematic study of the magnetic properties of low doped manganite films submitted to different oxygenation treatments. We have found that oxygenation dynamics depends critically of the strain field in the sample. The T{sub C} and the Mr increase as the oxygen content is increased. A decrease of the coercive field of the LSMO-STO films was observed, indicating that annealing treatments increase the oxygen content reducing oxygen vacancies.

  11. Content Analysis

    National Research Council Canada - National Science Library

    Rossi, George Bedinelli; Serralvo, Francisco Antonio; João, Belmiro Nascimento

    2014-01-01

    This study introduces the various definitions and types of content analysis. This type of analysis historically presents itself as a quantitative approach to data analysis and currently shows up as a qualitative approach...

  12. Content Marketing

    OpenAIRE

    LE, DUC

    2013-01-01

    The purpose of this thesis was to introduce the new trend in today’s marketing world: content marketing. It has been employed by many companies and organizations in the world and has been proven success even when it is still a fairly new topic. Five carefully selected theories of content marketing proposed by experts in the field has been collected, compared and displayed as originally and scientifically as possible in this thesis. The chosen theories provide a diversified perspectives of...

  13. Associated Analysis on Polymorphisms of UCP Genotypes, Reactive Oxygen Species Contents and Birth Weight with Three Chicken Breeds%鸡解耦联蛋白基因型与活性氧含量、初生重的相关性分析

    Institute of Scientific and Technical Information of China (English)

    程甲; 程曦; 朱庆鸿; 赵兴波

    2011-01-01

    为了研究解耦联蛋白基因(uncoupling protein,UCP)对鸡(Gallus gallus)初生重及活性氧含量的影响,本实验通过对3个品种鸡初生重、UCP C353T多态位点基因型以及肌肉组织活性氧(ROS)含量的测定,发现丝羽乌鸡ROS值显著低于白莱航、寿光鸡,UCPTT基因型ROS值显著高于CT和CC基因型,而ROS含量与雏鸡初生重之间存在着正向的相关性(r=0.5011),UCPTT基因型的初生重显著高于CT和CC基因型.实验结果揭示了鸡UCP基因型对初生重性状具有选择效应.%In order to explore the effect of uncoupling protein gene (UCP) on birth weight and content of reactive oxygen species (ROS) in chickens (Gallus gallus), the birth weight, UCP C353T mutation genotyping and muscle ROS contents from three chicken breeds were analyzed.The results indicated Silky chicken had higher ROS contents than that of White Leghorn and Shouguang chickens, and ROS contents for genotype TT of UCP appeared notably higher than that of CT and CC genotypes.ROS contents presented a positive correlation with chicken birth weight (r=0.5011).The birth weight for genotype TT of UCPdemonstrated notably higher than that of CT and CC genotype.The findings showed UCP genotypes can impact chicken birth weight for selections.

  14. TiNi shape memory alloys: effects of the fabrication route, the oxygen content and the zirconium or hafnium additions on the metallurgical characteristics and the thermomechanical properties; Alliages a memoires de forme de base TiNi: influence du mode de fabrication de la teneur en oxygene et de l`ajout de Zr ou Hf sur les caracteristiques metallurgiques et les proprietes mecaniques

    Energy Technology Data Exchange (ETDEWEB)

    Olier, P.

    1996-12-31

    In order to promote the development of Ti-Ni shape memory alloys, we have studied the correlation between the fabrication route, the chemical composition (O{sub 2} content, Zr or Hf additions), the metallurgical characteristics and the thermomechanical properties. A conventional sintering does not allow to obtain a homogeneous compound of pure Ti{sub 50}Ni{sub 50} alloy because of the occurrence of Kirkendall porosities which act as a diffusion barrier. An original process including combustion synthesis and hot-extrusion was successfully developed. Resulting products exhibit a smaller grain size (15-20{mu}m) and an enhanced workability in comparison with products obtained by arc-melting and subsequent hot rolling. The presence of oxygen in equiatomic Ti-Ni alloy induces the oxide precipitation of Ti{sub 4}Ni{sub 2}O{sub x} type (with x {<=} 1). The precipitated particle fraction is proportional to the oxygen nominal content of the alloy. We show that the decrease of the transformation temperatures is correlated with the decrease of Ti in solid solution due to Ti{sub 4}Ni{sub 2}O precipitation. Moreover, we find that a fine and homogenous oxide dispersion is suitable to decrease the grain size during hot rolling and to enhance to the one way shape memory properties. An increase of the typical transformation temperatures is obtained through of Zr or Hf (in substitution to Ti). But, an increase of the hardness is measured, and consequently the workability of the ternary alloys becomes reduced. However, it is worthwhile to point out that a Ti{sub 38}Ni{sub 50}Hf{sub 12} product obtained by arc melting and hot extrusion is able to fully recover an apparent plastic strain of more than 4% during tensile tests performed under special loading conditions. Such as behaviour is of great interest with respect to potential applications in a temperature range higher that 100 deg. C. (author). 105 refs.

  15. Artificial oxygen transport protein

    Science.gov (United States)

    Dutton, P. Leslie

    2014-09-30

    This invention provides heme-containing peptides capable of binding molecular oxygen at room temperature. These compounds may be useful in the absorption of molecular oxygen from molecular oxygen-containing atmospheres. Also included in the invention are methods for treating an oxygen transport deficiency in a mammal.

  16. Low content of Pt supported on Ni-MoCx/carbon black as a highly durable and active electrocatalyst for methanol oxidation, oxygen reduction and hydrogen evolution reactions in acidic condition

    Science.gov (United States)

    Zhang, Yan; Zang, Jianbing; Jia, Shaopei; Tian, Pengfei; Han, Chan; Wang, Yanhui

    2017-08-01

    Nickel and molybdenum carbide modified carbon black (Ni-MoCx/C) was synthesized by a two-step microwave-assisted deposition/carbonthermal reduction method and characterized by X-ray diffraction, transmission electron microscopy, energy dispersive spectroscopy and X-ray photoelectron spectroscopy. The as-prepared Ni-MoCx/C supported Pt (10 wt%) electrocatalyst (10Pt/Ni-MoCx/C) was synthesized through a microwave-assisted reduction method and 10Pt/Ni-MoCx/C exhibited high electrocatalytic activity for methanol oxidation, oxygen reduction and hydrogen evolution reactions. Results showed that 10Pt/Ni-MoCx/C electrocatalyst had better electrocatalytic activity and stability performance than 20 wt% Pt/C (20Pt/C) electrocatalyst. Among them, the electrochemical surface area of 10Pt/Ni-MoCx/C reached 68.4 m2 g-1, which was higher than that of 20Pt/C (63.2 m2 g-1). The enhanced stability and activity of 10Pt/Ni-MoCx/C electrocatalyst were attributed to: (1) an anchoring effect of Ni and MoCx formed during carbonthermal reduction process; (2) a synergistic effect among Pt, Ni, MoOx and MoCx. These findings indicated that 10Pt/Ni-MoCx/C was a promising electrocatalyst for direct methanol fuel cells.

  17. Oxygen sensing and signaling.

    Science.gov (United States)

    van Dongen, Joost T; Licausi, Francesco

    2015-01-01

    Oxygen is an indispensable substrate for many biochemical reactions in plants, including energy metabolism (respiration). Despite its importance, plants lack an active transport mechanism to distribute oxygen to all cells. Therefore, steep oxygen gradients occur within most plant tissues, which can be exacerbated by environmental perturbations that further reduce oxygen availability. Plants possess various responses to cope with spatial and temporal variations in oxygen availability, many of which involve metabolic adaptations to deal with energy crises induced by low oxygen. Responses are induced gradually when oxygen concentrations decrease and are rapidly reversed upon reoxygenation. A direct effect of the oxygen level can be observed in the stability, and thus activity, of various transcription factors that control the expression of hypoxia-induced genes. Additional signaling pathways are activated by the impact of oxygen deficiency on mitochondrial and chloroplast functioning. Here, we describe the molecular components of the oxygen-sensing pathway.

  18. Oxygen-enhanced combustion

    CERN Document Server

    Baukal, Charles E

    2013-01-01

    Combustion technology has traditionally been dominated by air/fuel combustion. However, two developments have increased the significance of oxygen-enhanced combustion-new technologies that produce oxygen less expensively and the increased importance of environmental regulations. Advantages of oxygen-enhanced combustion include less pollutant emissions as well as increased energy efficiency and productivity. Oxygen-Enhanced Combustion, Second Edition compiles information about using oxygen to enhance industrial heating and melting processes. It integrates fundamental principles, applications, a

  19. Recharge Area on the Slopes of Volcano Based on Geological Setting, Content of Deuterium and Oxygen Isotopes of Groundwater Chemistry: Case Study on the Slopes of Salak Mountain, West Java

    Directory of Open Access Journals (Sweden)

    Hendarmawan

    2011-09-01

    Full Text Available Indonesian is huge areas that have the highest precipitation in the world, therefore water deficit of groundwater is often happened at anywhere. This study was related to determination of recharge area with approached by combining geological setting, stable isotopes and chemical content of groundwater. Case study was carried out at surrounding the Cicurug area, Sukabumi Prefecture, West Java Province. The area is the slopes of Salak Mountain that have elevation of 400 until 1,200 m mean sea level (msl. While, much groundwater supplies industry activities on elevation 450-500 m msl. Based on data and result analysis of the studies, the recharge areas was not around peak of mountain or near, but water infiltrated on elevation of 700-800 m msl for groundwater exploited by industries. Therefore, the accurate determination of recharge area becomes a key for the groundwater sustainability.

  20. Rule of oxygen transmission in dump leaching

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    According to the chemical equations, the flux and concentration of oxygen required during bacterial leaching sulfuric mineral were investigated; the rule of air bubble transmitted in granular was researched in the Dump Leaching Plant of Dexing Copper Mine. The results show that lack of oxygen in dump leaching is the critical factor of restricting leaching reaction. Pyrite is the primary oxygen-consuming mineral in bioleaching. When its content is too high, it needs a great deal of oxygen for reaction and competes for the finite oxygen with objective minerals, and thus the leaching velocity decreases greatly. The average size of ore particles and diameter of bubbles are the key parameters affecting the mass transfer coefficient. Reverse analysis was adopted, and it shows that 44.8 m3 air per unit ore can meet the requirement of production if the molar ratio of pyrite to chalcopyrite is 10.

  1. Transabdominal oxygenation using perfluorocarbons.

    Science.gov (United States)

    Chiba, T; Harrison, M R; Ohkubo, T; Rollins, M D; Albanese, C T; Jennings, R W

    1999-05-01

    Evaluation of the intraabdominal (intraperitoneal and intraluminal) administration of oxygen-saturated perfluorocarbon on both portal and arterial blood oxygenation. Eight male rabbits were divided into the test (n = 5) and control (n = 3) groups. Each underwent intrajejunal, intraperitoneal, and intravascular (artery, portal vein) catheter placements along with ligation of the duodenum and the terminal ileum under general anesthesia. The test group received oxygen-saturated perfluorotripropylamine (FTPA), and the control group received oxygen desaturated FTPA. The oxygen delivery was assessed by serial blood gas measurements before and after the administration of FTPA. The administration of oxygen-saturated FTPA significantly increased the partial pressure of oxygen within both the arterial and the portal venous blood (PaO2, PpVO2) without significant changes in PCO2 values. Oxygen desaturated FTPA failed to show any effects on blood gas values. Compared with oxygen desaturated FTPA, oxygen-saturated FTPA increased PaO2, PpVO2, and oxygen saturation (artery, portal vein) significantly at some, but not all of the time-points measured. The intraabdominal administration of saturated FTPA improved both the portal venous and the arterial oxygenation. This new mode of oxygenation may be helpful as an adjunct to conventional oxygen delivery systems.

  2. Treatment of exceedances of oil content in cooling water resulted from inner leakage of oil cooler of oxygen compressor%氧压机油冷却器内漏使冷却水中油含量超标的处理

    Institute of Scientific and Technical Information of China (English)

    汪雁; 史浪涛

    2011-01-01

    The inner leakage of oil cooler of oxygen compressor would result in exceedances of oil content in cooling water. Once oil enters the air separation system, it will result in blocking of main heat exchanger. The trouble of inner leakage of oil cooler during run of Model 2TYS100 + 2TYS76 oxygen compressor is outlined, the causes for the trouble are analyzed, and the troubleshooting process of oil cooler and the correction method of residual oil in the circulation cooling water system are described.%氧压机油冷却器内漏将导致冷却水中油含量超标,一旦油进入空分系统,将引起主换热器堵塞故障。介绍2TYS100+2TYS76型氧压机在运行过程中油冷却器发生内漏的故障现象,分析故障原因,阐述对油冷却器的故障处理过程及循环冷却水系统残油的处理方法。

  3. Oxygen Behavior in Bulk Amorphous Zr-base Alloy

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Bulk Zr55Al10Ni5Cu30 metallic glass plates with a dimension of 85 mm×35mm×4 mm and a complicated plate werefabricated by injecting casting method using spongy zirconium and industrial purity aluminum, nickel and copper asraw materials. It was shown that the holding time of liquid metals at elevated temperatures had a great influence onthe oxygen content of the plates due to the contamination resulting from the atmosphere. Increasing holding timeresulted in the increase of oxygen content in the injected alloy. The glass transition temperatures of the bulk metallicglass plates are higher than that reported in the literature and crystallization temperature is lower for the one withhigher oxygen content at the same heating rate. The extension of the undercooled liquid region △Tx reaching about87 K is 3 K higher than that previously reported and 26 K higher than that with oxygen content of 0.076 wt pct forthe one with oxygen content as high as 0.065 wt pct. Therefore the oxygen content of the alloy has a significantinfluence on the glass forming ability and thermal stability of bulk metal glass. It is suggested that direct correlationbetween high glass forming ability and large △Tx is only valid for a well-defined Iow oxygen concentration or has tobe reconsidered by incorporating oxygen as an additional alloying element.

  4. Excess posthypoxic oxygen consumption in rainbow trout (Oncorhynchus mykiss): recovery in normoxia and hypoxia

    DEFF Research Database (Denmark)

    Svendsen, Jon Christian; Steffensen, John Fleng; Aarestrup, Kim

    2012-01-01

    Under certain conditions, a number of fish species may perform brief excursions into severe hypoxia and return to water with a higher oxygen content. The term severe hypoxia describes oxygen conditions that are below the critical oxygen saturation (S(crit)), defined here as the oxygen threshold...... at which the standard metabolic rate becomes dependent upon the ambient oxygen content. Using rainbow trout (Oncorhynchus mykiss (Walbaum, 1792), this study quantified the excess posthypoxic oxygen consumption (EPHOC) occurring after exposure to oxygen availability below S(crit). Tests showed that S...

  5. The jumbo squid, Dosidicus gigas (Ommastrephidae), living in oxygen minimum zones II: Blood-oxygen binding

    Science.gov (United States)

    Seibel, Brad A.

    2013-10-01

    Dosidicus gigas is a large, metabolically active squid that migrates across a strong oxygen and temperature gradient in the Eastern Pacific. Here we analyze the oxygen-binding properties of the squid's respiratory protein (hemocyanin, Hc) that facilitate such activity. A high Hc-oxygen affinity, strong temperature dependence, and pronounced pH sensitivity (P50=0.009T2.03, pH 7.4; Bohr coefficient=ΔlogP50/ΔpH=-1.55+0.034T) of oxygen binding facilitate night-time foraging in the upper water column, and support suppressed oxygen demand in hypoxic waters at greater depths. Expanding hypoxia may act to alter the species habitable depth range. This analysis supports the contention that ocean acidification could limit oxygen carrying capacity in squids at warmer temperature leading to reduced activity levels or altered distribution.

  6. Workshop on Oxygen in the Terrestrial Planets

    Science.gov (United States)

    2004-01-01

    This volume contains abstracts that have been accepted for presentation at the Workshop on Oxygen in the Terrestrial Planets, July 20-23,2004, Santa Fe, New Mexico. The contents include: 1) Experimental Constraints on Oxygen and Other Light Element Partitioning During Planetary Core Formation; 2) In Situ Determination of Fe(3+)/SigmaFe of Spinels by Electron Microprobe: An Evaluation of the Flank Method; 3) The Effect of Oxygen Fugacity on Large-Strain Deformation and Recrystallization of Olivine; 4) Plagioclase-Liquid Trace Element Oxygen Barometry and Oxygen Behaviour in Closed and Open System Magmatic Processes; 5) Core Formation in the Earth: Constraints from Ni and Co; 6) Oxygen Isotopic Compositions of the Terrestrial Planets; 7) The Effect of Oxygen Fugacity on Electrical Conduction of Olivine and Implications for Earth s Mantle; 8) Redox Chemical Diffusion in Silicate Melts: The Impact of the Semiconductor Condition; 9) Ultra-High Temperature Effects in Earth s Magma Ocean: Pt and W Partitioning; 10) Terrestrial Oxygen and Hydrogen Isotope Variations: Primordial Values, Systematics, Subsolidus Effects, Planetary Comparisons, and the Role of Water; 11) Redox State of the Moon s Interior; 12) How did the Terrestrial Planets Acquire Their Water?; 13) Molecular Oxygen Mixing Ratio and Its Seasonal Variability in the Martian Atmosphere; 14) Exchange Between the Atmosphere and the Regolith of Mars: Discussion of Oxygen and Sulfur Isotope Evidence; 15) Oxygen and Hydrogen Isotope Systematics of Atmospheric Water Vapor and Meteoric Waters: Evidence from North Texas; 16) Implications of Isotopic and Redox Heterogeneities in Silicate Reservoirs on Mars; 17) Oxygen Isotopic Variation of the Terrestrial Planets; 18) Redox Exchanges in Hydrous Magma; 19) Hydrothermal Systems on Terrestrial Planets: Lessons from Earth; 20) Oxygen in Martian Meteorites: A Review of Results from Mineral Equilibria Oxybarometers; 21) Non-Linear Fractionation of Oxygen Isotopes Implanted in

  7. Notch sensitivity of hydrogenated oxygen-strengthened titanium

    Science.gov (United States)

    Wasz, M. L.; Ko, C. C.; Brotzen, F. R.; Mclellan, R. B.

    1990-01-01

    While earlier studies have shown that the tensile properties and fracture test intensity factors of oxygen-strengthened Ti remain nearly unaffected by the presence of about 70 ppm (weight) hydrogen, the Charpy V-notch test-determined impact properties of oxygen-bearing Ti are strongly affected by the presence of hydrogen. The present study establishes that, concurrently with the strengthening effect of oxygen, there is a substantial lowering of ductility. The presence of hydrogen has virtually no effect on the notch strength of Ti alloys of either low or high oxygen content, where hydrogen contents lie in the 25-80 range.

  8. Oxygen transport membrane

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a novel composite oxygen transport membrane as well as its preparation and uses thereof.......The present invention relates to a novel composite oxygen transport membrane as well as its preparation and uses thereof....

  9. Hyperbaric oxygen therapy

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002375.htm Hyperbaric oxygen therapy To use the sharing features on this page, please enable JavaScript. Hyperbaric oxygen therapy uses a special pressure chamber to increase ...

  10. Biogeochemistry: Oxygen burrowed away

    NARCIS (Netherlands)

    Meysman, F.J.R.

    2014-01-01

    Multicellular animals probably evolved at the seafloor after a rise in oceanic oxygen levels. Biogeochemical model simulations suggest that as these animals started to rework the seafloor, they triggered a negative feedback that reduced global oxygen.

  11. Biogeochemistry: Oxygen burrowed away

    NARCIS (Netherlands)

    Meysman, F.J.R.

    2014-01-01

    Multicellular animals probably evolved at the seafloor after a rise in oceanic oxygen levels. Biogeochemical model simulations suggest that as these animals started to rework the seafloor, they triggered a negative feedback that reduced global oxygen.

  12. Home Oxygen Therapy

    Science.gov (United States)

    ... Teenagers Living With Lung Disease Articles written by Respiratory Experts Home Oxygen Therapy More and more people are using oxygen therapy ... April 12, 2012 Revised: © 2017 American Association for Respiratory Care

  13. Oxygen evolution reaction catalysis

    Science.gov (United States)

    Haber, Joel A.; Jin, Jian; Xiang, Chengxiang; Gregoire, John M.; Jones, Ryan J.; Guevarra, Dan W.; Shinde, Aniketa A.

    2016-09-06

    An Oxygen Evolution Reaction (OER) catalyst includes a metal oxide that includes oxygen, cerium, and one or more second metals. In some instances, the cerium is 10 to 80 molar % of the metals in the metal oxide and/or the catalyst includes two or more second metals. The OER catalyst can be included in or on an electrode. The electrode can be arranged in an oxygen evolution system such that the Oxygen Evolution Reaction occurs at the electrode.

  14. Cryptococcus neoformans and oxygen

    OpenAIRE

    Vladislav,Raclavsky

    2006-01-01

    Oxygen is essential to life of all organisms except for obligate anaerobic species, because it is necessary for energy generation and also for some biosynthetic pathways. However, sensitivity to low oxygen levels can vary widely in different organisms and cell types. The pathogenic yeast species Cryptococcus neoformans is known to love oxygen. In response to the lack of oxygen (hypoxia), this yeast delays budding without resigning DNA replication, which eventually results in unique cell cycle...

  15. Proterozoic atmospheric oxygen

    DEFF Research Database (Denmark)

    Canfield, Donald Eugene

    2014-01-01

    This article is concerned with the evolution of atmospheric oxygen concentrations through the Proterozoic Eon. In particular, this article will seek to place the history of atmospheric oxygenation through the Proterozoic Eon in the context of the evolving physical environment including the history...... of continental growth and volcanic outgassing, as well as biogeochemical processing of elements within the oceans. The author will seek to explore constraints on the history of oxygenation and understand which processes have regulated oxygen through this eon....

  16. An oxygen slow-releasing material and its application in water remediation as oxygen supplier.

    Science.gov (United States)

    Zhou, Yanbo; Fang, Xingbin; Zhang, Zhiqing; Hu, Yonghua; Lu, Jun

    2017-01-12

    In this study, an oxygen slow-releasing material (OSRM) consisting of calcium peroxide (CaO2), stearic acid (SA) and quartz sand was used to improve oxygen supply during bioremediation. The oxygen-releasing rates of CaO2 powder and OSRM with different SA contents were investigated. The efficacy of OSRM as an oxygen supplier was assessed by water remediation experiments using activated sludge. Results showed that CaO2 powder was effectively embedded by SA under anhydrous conditions. The oxygen-releasing rate decreased with increasing SA contents. Moreover, the OSRM exhibited higher oxygen-releasing capacity, and more effective pH control ability than CaO2 powder. The water remediation experiments showed better removal of COD and [Formula: see text] with OSRM as the oxygen supplier. These results provided detailed information when CaO2 was applied as the oxygen supplier in water remediation, which can serve as references for field application of bioremediation.

  17. Effects of oxygen incorporation in GeSbTe films on electrical properties and thermal stability

    Science.gov (United States)

    Jang, Moon Hyung; Park, Seung Jong; Lim, Dong Hyeok; Park, Sung Jin; Cho, Mann-Ho; Cho, Seong Jin; Cho, Yoon Ho; Lee, Jong-Heun

    2010-03-01

    Oxygen incorporated Ge2Sb2Te5 (GST) films were prepared by an ion beam sputtering deposition method. I-V curves of the oxygen incorporated GST active layer showed that the threshold voltage (Vth) varied, depending on the level of incorporated oxygen. In the case of a GST film with an elevated oxygen content of 30.8%, the GST layer melted at 9.02 V due to the instability conferred by the high oxygen content. The formation of Ge-deficient hexagonal phases such as GeSb2Te4 and Sb2Te3 appear to be responsible for the Vth variation. Impedance analyses indicated that the resistance in GST films with oxygen contents of 16.7% and 21.7% had different origins. Thermal desorption spectroscopy data indicate that moisture and hydrocarbons were more readily desorbed at higher oxygen content because the oxygen incorporated GST films are more hydrophilic than undoped GST films.

  18. MAIN CONTENTS

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Discussion on the Modern Agriculture Management Mode and its Innovation in China Mode of agricultural management is organic unify between form of agriculture management and way of agriculture management. Changes of agricultural management form are the content of system innovation;Transformation of agricultural management way belongs to the category of technical progress. We found that, precision agriculture with the moderate scale by professional farmers is the dominant mode of agricultural management. Coexisting of multiple modes is the pattern and evolution trend of modern agriculture management mode. The precision agriculture based on household business of moderate scale mode, we needs of rural economd socialization of

  19. Content Analysis

    Directory of Open Access Journals (Sweden)

    George Bedinelli Rossi

    2014-09-01

    Full Text Available This study introduces the various definitions and types of content analysis. This type of analysis historically presents itself as a quantitative approach to data analysis and currently shows up as a qualitative approach. The most common types are the conceptual and relational analysis. The latter receives influences of linguistic, cognitive and mental models and it is subdivided in affective extraction, analysis of proximity and cognitive mapping. Regarding the importance of this type of analysis, we have quantitative and qualitative character and the latter approach can be used to identify hypotheses, theoretical constructs or even models that can be tested by multivariate statistical techniques or even by experiments. 

  20. Oxygen precipitation behavior in heavily arsenic doped silicon crystals

    Science.gov (United States)

    Haringer, Stephan; Gambaro, Daniela; Porrini, Maria

    2017-01-01

    Silicon crystals containing different levels of arsenic concentration and oxygen content were grown, and samples were taken at various positions along the crystal, to study the influence of three main factors, i.e. the initial oxygen content, the dopant concentration and the thermal history, on the nucleation of oxygen precipitates during crystal growth and cooling in the puller. The crystal thermal history was reconstructed by means of computer modeling, simulating the temperature distribution in the crystal at several growth stages. The oxygen precipitation was characterized after a thermal cycle of 4 h at 800 °C for nuclei stabilization +16 h at 1000 °C for nuclei growth. Oxygen precipitates were counted under microscope on the cleaved sample surface after preferential etching. Lightly doped silicon samples were also included, as reference. Our results show that even in heavily arsenic doped silicon the oxygen precipitation is a strong function of the initial oxygen concentration, similar to what has been observed for lightly doped silicon. In addition, a precipitation retardation effect is observed in the arsenic doped samples when the dopant concentration is higher than 1.7×1019 cm-3 compared to lightly doped samples with the same initial oxygen content and crystal thermal history. Finally, a long permanence time of the crystal in the temperature range between 450 °C and 750 °C enhances the oxygen precipitation, showing that this is an effective temperature range for oxygen precipitation nucleation in heavily arsenic doped silicon.

  1. 短期冲刺间歇训练对青年男子篮球运动员肌氧含量和运动能力的影响%Effects of short-term sprint interval training on the muscle oxygen content and athletic capacity of young male basketball players

    Institute of Scientific and Technical Information of China (English)

    张学领

    2016-01-01

    The author observed the effects of short-term sprint interval training on the muscle oxygen content and athletic capacity of young male basketball players, so as to provide a criterion for establishing training plans in a scientific and rational way. The author divided 30 young male basketball players randomly into an experiment group (EG,n=15) and a control group (CG,n=15), let the players in group CG have normal training and let the players in group EG have 2 times of print interval training a week on the basis of normal training for 4 weeks, and respectively before and after the experiment, measured their aerobic exercise capacity by means of progressively increased load experiment, measured their anaerobic exercise capacity by means of 30s Wingate experiment, monitored the chang-ing of vastus lateralis muscle oxygen content during high intensity interval exercise experiment (repeated 5 times of 30s Wingate experiment, interval 4min) by means of near-infrared spectroscopy (NIRS), and revealed the following findings: after the experiment, as compared with those measured before the experiment, the maximum oxygen up-take and maximum aerobic power of the testees in group EG increased (P0.05); all the indexes of the testees in group CG had no significant change (P>0.05). The said findings indicated that short-term print interval training improved the aerobic and anaerobic exercise capacities of young male basketball players as well as their peripheral skeletal muscle’s oxygen uptake capacity during interval exercise.%观察短期冲刺间歇训练对运动员运动中肌氧含量以及运动能力的影响,为科学合理制定训练计划提供依据。将30名青年男子篮球运动员随机分为实验组(EG,n=15名)和对照组(CG,n=15名)。CG运动员正常训练,EG在正常训练基础上每周进行2次冲刺间歇训练,实验周期为4周。分别于实验前后利用递增负荷实验测定有氧运动能力;30 s Wingate实验测定无

  2. 42 CFR 414.226 - Oxygen and oxygen equipment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Oxygen and oxygen equipment. 414.226 Section 414... Equipment and Prosthetic and Orthotic Devices § 414.226 Oxygen and oxygen equipment. (a) Payment rules—(1) Oxygen equipment. Payment for rental of oxygen equipment is made based on a monthly fee schedule...

  3. On-line monitoring of oxygen as a method to qualify the oxygen consumption rate of wines.

    Science.gov (United States)

    Nevares, Ignacio; Martínez-Martínez, Víctor; Martínez-Gil, Ana; Martín, Roberto; Laurie, V Felipe; Del Álamo-Sanza, María

    2017-08-15

    Measuring the oxygen content during winemaking and bottle storage has become increasingly popular due to its impact on the sensory quality and longevity of wines. Nevertheless, only a few attempts to describe the kinetics of oxygen consumption based on the chemical composition of wines have been published. Therefore, this study proposes firstly a new fitting approach describing oxygen consuming kinetics and secondly the use of an Artificial Neural Network approach to describe and compare the oxygen avidity of wines according to their basic chemical composition (i.e. the content of ethanol, titratable acidity, total sulfur dioxide, total phenolics, iron and copper). The results showed no significant differences in the oxygen consumption rate between white and red wines, and allowed the sorting of the wines studied according to their oxygen consumption rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Oxygen Requirements for the Cambrian Explosion

    Institute of Scientific and Technical Information of China (English)

    Xingliang Zhang; Linhao Cui

    2016-01-01

    Hypoxic tolerance experiments may be helpful to constrain the oxygen requirement for animal evolution. Based on literature review, available data demonstrate that fishes are more sensitive to hypoxia than crustaceans and echinoderms, which in turn are more sensitive than annelids, whilst mollusks are the least sensitive. Mortalities occur where O2 concentrations are below 2.0 mg/L, equivalent to saturation with oxygen content about 25% PAL (present atmospheric level). Therefore, the minimal oxygen requirement for maintaining animal diversity since Cambrian is determined as 25% PAL. The traditional view is that a rise in atmospheric oxygen concentrations led to the oxygenation of the ocean, thus triggering the evolution of animals. Geological and geochemical studies suggest a constant increase of the oxygen level and a contraction of anoxic oceans during Ediacaran–Cambrian transition when the world oceans experienced a rapid diversification of metazoan lineages. However, fossil first appearances of animal phyla are obviously asynchronous and episodic, showing a sequence as:basal metazoans>lophotrochozoans>ecdysozoans and deuterostomes. According to hitherto known data of fossil record and hypoxic sensitivity of animals, the appearance sequence of different animals is broadly consistent with their hypoxic sensitivity:animals like molluscs and annelids that are less sensitive to hypoxia appeared earlier, while animals like echinoderms and fishes that are more sensitive to hypoxia came later. Therefore, it is very likely that the appearance order of animals is corresponding to the increasing oxygen level and/or the contraction of anoxic oceans during Ediacaran–Cambrian transition.

  5. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  6. Constriction of collateral arteries induced by "head-up tilt" in patients with occlusive arterial disease of the legs

    DEFF Research Database (Denmark)

    Agerskov, K; Henriksen, O; Tønnesen, K H

    1981-01-01

    . Relative change in blood flow in the leg during tilt was estimated by changes in arterio-venous oxygen differences and by the indicator dilution technique in nine patients. Head-up tilt caused a decrease in leg blood flow of 36% corresponding to an increase in total vascular resistance of 57%. Tilt did......The effect of head-up tilt on leg blood flow and segmental arterial blood pressures was studied in 21 patients with occlusion or severe stenosis of the common or superficial femoral artery. Arterial pressure was measured directly in the brachial artery, common femoral artery and popliteal artery...... not change the pressure gradient from femoral to popliteal artery in the patients with occlusion of the superficial femoral artery, indicating that the flow resistance offered by the collateral arteries had increased. In a bilateral sympathectomised patient the increase in collateral resistance was almost...

  7. Physical determinants of vascular network remodeling during tumor growth.

    Science.gov (United States)

    Welter, M; Rieger, H

    2010-10-01

    The process in which a growing tumor transforms a hierarchically organized arterio-venous blood vessel network into a tumor specific vasculature is analyzed with a theoretical model. The physical determinants of this remodeling involve the morphological and hydrodynamic properties of the initial network, generation of new vessels (sprouting angiogenesis), vessel dilation (circumferential growth), vessel regression, tumor cell proliferation and death, and the interdependence of these processes via spatio-temporal changes of blood flow parameters, oxygen/nutrient supply and growth factor concentration fields. The emerging tumor vasculature is non-hierarchical, compartmentalized into well-characterized zones, displays a complex geometry with necrotic zones and "hot spots" of increased vascular density and blood flow of varying size, and transports drug injections efficiently. Implications for current theoretical views on tumor-induced angiogenesis are discussed.

  8. Integrated turbomachine oxygen plant

    Science.gov (United States)

    Anand, Ashok Kumar; DePuy, Richard Anthony; Muthaiah, Veerappan

    2014-06-17

    An integrated turbomachine oxygen plant includes a turbomachine and an air separation unit. One or more compressor pathways flow compressed air from a compressor through one or more of a combustor and a turbine expander to cool the combustor and/or the turbine expander. An air separation unit is operably connected to the one or more compressor pathways and is configured to separate the compressed air into oxygen and oxygen-depleted air. A method of air separation in an integrated turbomachine oxygen plant includes compressing a flow of air in a compressor of a turbomachine. The compressed flow of air is flowed through one or more of a combustor and a turbine expander of the turbomachine to cool the combustor and/or the turbine expander. The compressed flow of air is directed to an air separation unit and is separated into oxygen and oxygen-depleted air.

  9. Ambient oxygen promotes tumorigenesis.

    Directory of Open Access Journals (Sweden)

    Ho Joong Sung

    Full Text Available Oxygen serves as an essential factor for oxidative stress, and it has been shown to be a mutagen in bacteria. While it is well established that ambient oxygen can also cause genomic instability in cultured mammalian cells, its effect on de novo tumorigenesis at the organismal level is unclear. Herein, by decreasing ambient oxygen exposure, we report a ∼50% increase in the median tumor-free survival time of p53-/- mice. In the thymus, reducing oxygen exposure decreased the levels of oxidative DNA damage and RAG recombinase, both of which are known to promote lymphomagenesis in p53-/- mice. Oxygen is further shown to be associated with genomic instability in two additional cancer models involving the APC tumor suppressor gene and chemical carcinogenesis. Together, these observations represent the first report directly testing the effect of ambient oxygen on de novo tumorigenesis and provide important physiologic evidence demonstrating its critical role in increasing genomic instability in vivo.

  10. Benthic foraminifera from the Arabian Sea oxygen minimum zone: towards a paleo-oxygenation proxy.

    Science.gov (United States)

    Clemence, Caulle; Meryem, Mojtahid; Karoliina, Koho; Andy, Gooday; Gert-Jan, Reichart; Gerhard, Schmiedl; Frans, Jorissen

    2014-05-01

    Benthic foraminifera from the Arabian Sea oxygen minimum zone: towards a paleo-oxygenation proxy. C. Caulle1, M. Mojtahid1, K. Koho2,3, A. Gooday4, G. J. Reichart2,3, G. Schmiedl5, F. Jorissen1 1UMR CNRS 6112 LPG-BIAF, University of Angers, 2 bd Lavoisier, 49045 Angers Cedex 2Utrecht University, Faculty of Geosciences, Department of Earth Sciences, Budapestlaan 4, 3584 CD Utrecht, The Netherlands 3Royal Netherland Institute for Sea Research (Royal NIOZ), Landsdiep 4, 1797 SZ 't Horntje (Texel) 4Southampton Oceanography Centre, Empress Dock, European Way, Southampton SO14 3ZH, UK 5Department of Geosciences, University of Hamburg, Bundesstraße 55, 20146 Hamburg, Germany The thermohaline circulation oxygenates the deep ocean sediment and therefore enables aerobic life on the sea-floor. In the past, interruption of this deep water formation occurred several times causing hypoxic to anoxic conditions on the sea-floor leading to major ecological turnover. A better understanding of the interaction between climate and bottom water oxygenation is therefore essential in order to predict future oceanic responses. Presently, permanent (stable over decadal timescale) low-oxygen conditions occur naturally at mid-water depths in the northern Indian Ocean (Arabian Sea). Oxygen Minimum Zones (OMZ) are key areas to understand the hypoxic-anoxic events and their impact on the benthic ecosystem. In this context, a good knowledge of the ecology and life cycle adaptations of the benthic foraminiferal assemblages living in these low oxygen areas is essential. A series of multicores were recovered from three transects showing an oxygen gradient across the OMZ: the Murray Ridge, the Oman margin and the Indian margin. The stations located at the same depths showed slightly different oxygen concentrations and large differences in organic matter content. These differences are mainly related to the geographic location in the Arabian Sea. We investigated at these stations live and dead benthic

  11. Solid state oxygen sensor

    Science.gov (United States)

    Garzon, F.H.; Brosha, E.L.

    1997-12-09

    A potentiometric oxygen sensor is formed having a logarithmic response to a differential oxygen concentration while operating as a Nernstian-type sensor. Very thin films of mixed conducting oxide materials form electrode services while permitting diffusional oxygen access to the interface between the zirconia electrolyte and the electrode. Diffusion of oxygen through the mixed oxide is not rate-limiting. Metal electrodes are not used so that morphological changes in the electrode structure do not occur during extended operation at elevated temperatures. 6 figs.

  12. Measuring tissue oxygenation

    Science.gov (United States)

    Soyemi, Olusola O. (Inventor); Soller, Babs R. (Inventor); Yang, Ye (Inventor)

    2009-01-01

    Methods and systems for calculating tissue oxygenation, e.g., oxygen saturation, in a target tissue are disclosed. In some embodiments, the methods include: (a) directing incident radiation to a target tissue and determining reflectance spectra of the target tissue by measuring intensities of reflected radiation from the target tissue at a plurality of radiation wavelengths; (b) correcting the measured intensities of the reflectance spectra to reduce contributions thereto from skin and fat layers through which the incident radiation propagates; (c) determining oxygen saturation in the target tissue based on the corrected reflectance spectra; and (d) outputting the determined value of oxygen saturation.

  13. Fístula arteriovenosa postraumática: tratamiento endovascular. Revisión de la literatura y presentación de un caso clínico Endovascular treatment of a post-traumatic arterio-venous fistula: Presentation of a clinical case and literature review

    Directory of Open Access Journals (Sweden)

    R. Sánchez

    2010-06-01

    Full Text Available Las fístulas arteriovenosas en la cabeza y el cuello son entidades poco frecuentes. La mayoría es secundaria a heridas penetrantes por arma blanca. Se describe el tratamiento exitoso mediante cirugía endovascular de una fístula postraumática tras una herida penetrante entre la arteria maxilar interna izquierda y la vena yugular externa. A través de este caso clínico y la revisión de la literatura se ilustran las causas, manifestaciones, estudio radiológico y tratamiento de una fístula postraumática entre la arteria maxilar interna y la vena yugular externa. A través de este caso clínico se demuestra la utilidad de los procedimientos endovasculares en el tratamiento de estas complicaciones.Traumatic arteriovenous fistulas of the head and neck region are uncommon. The majority are due to penetration of blunt injury. We describe a successful endovascular treatment of a posttraumatic fistula between the left maxillary artery and the external jugular vein due to a penetration injury. This case and a review of the literature illustrate the causes, manifestations, image studies and treatment for a posttraumatic fistula between the maxillary artery and the external jugular vein. This case demonstrate the utility of endovascular treatment of head and neck injuries complications.

  14. Cerebral Tissue Oxygenation during Immediate Neonatal Transition and Resuscitation

    Science.gov (United States)

    Pichler, Gerhard; Schmölzer, Georg M.; Urlesberger, Berndt

    2017-01-01

    This article provides a review of cerebral tissue oxygenation during immediate transition after birth in human neonates. Recommended routine monitoring, especially if resuscitation is needed, during this period includes arterial oxygen saturation and heart rate measured by pulse oximetry and electrocardiogram. However, there is increasing interest to monitor in addition with near-infrared spectroscopy (NIRS) the oxygenation of the brain. There is a different pattern of increase between cerebral tissue oxygenation and arterial oxygen saturation during the immediate transition, with cerebral tissue oxygenation reaching a plateau faster than arterial oxygen saturation. Differences can be explained, since cerebral tissue oxygenation is not only affected by arterial oxygen saturation but also by cerebral blood flow, hemoglobin content, and cerebral oxygen consumption. Normal values have already been established for different devices, gestational ages, and modes of delivery in neonates without any medical support. Cerebral hypoxia during immediate transition might cause brain damage. In preterm neonates with cerebral hemorrhage evolving in the first week after birth, the cerebral tissue oxygenation is already lower in the first minutes after birth compared to preterm neonates without cerebral hemorrhage. Using cerebral NIRS in combination with intervention guidelines has been shown to reduce the burden of cerebral hypoxia in preterm neonates. Cerebral tissue oxygenation during immediate transition seems to have an impact on outcome, whereby NIRS monitoring is feasible and has the advantage of continuous, non-invasive recording. The impact of NIRS monitoring and interventions on short- and long-term outcomes still need to be evaluated. PMID:28280719

  15. In situ measurements of oxygen dynamics in unsaturated archaeological deposits

    DEFF Research Database (Denmark)

    Matthiesen, Henning; Hollesen, Jørgen; Dunlop, Rory

    2015-01-01

    Oxygen is a key parameter in the degradation of archaeological material, but little is known of its dynamics in situ. In this study, 10 optical oxygen sensors placed in a 2 m deep test pit in the cultural deposits at Bryggen in Bergen have monitored oxygen concentrations every half hour for more ...... of the soil exceeds 10–15% vol, while oxygen dissolved in infiltrating rainwater is of less importance for the supply of oxygen in the unsaturated zone.......Oxygen is a key parameter in the degradation of archaeological material, but little is known of its dynamics in situ. In this study, 10 optical oxygen sensors placed in a 2 m deep test pit in the cultural deposits at Bryggen in Bergen have monitored oxygen concentrations every half hour for more...... than a year. It is shown that there is a significant spatial and temporal variation in the oxygen concentration, which is correlated to measured soil characteristics, precipitation, soil water content and degradation of organic material. In these deposits oxygen typically occurs when the air content...

  16. Normative database of retinal oximetry in Asian Indian eyes.

    Directory of Open Access Journals (Sweden)

    Ashwin Mohan

    Full Text Available To study the oxygen saturation profile in normal Asian Indian eyes.A cross sectional prospective study.Ninety eight consecutive patients presenting to our hospital with best corrected distance visual acuity (BCVA of 20/20 and a normal ophthalmic examination were included in the study. Patients having any ocular or systemic disease were excluded from the study.Oximetry was performed on all subjects with the Oxymap T1 retinal oximeter (Oxymap hf, Reykjavik, Iceland.The images were analysed for oxygen saturation and diameter.The mean age was 33 years (Range: 18-63; SD: 12.4. The average arteriolar saturation was 90.3 ± 6.6% and the venous saturation was 56.9% ± 6.3. The average A-V (arterio-venous difference was 33.2% ± 5.2. There was an increase in arteriolar (R2 = 0.264; p=0.001 and venous saturation (R2 = 0.151; p=0.001 with age. There was no significant change in the arterio-venous saturation difference (AVSD. The inferotemporal quadrant had the lowest saturations. Age correlated positively with ocular perfusion pressure (OPP(R2 = 0.07; p=0.007. OPP correlated positively with global arteriolar saturation (R2=0.057, p=0.018.This study provides the normative database for an Indian population and is comparable to previous studies. Age, vessel diameter and OPP were the significant factors that influenced the saturation. Arteriolar and venous saturations increased with age while the AVSD did not change significantly.

  17. On the Solar Nickel and Oxygen Abundances

    Science.gov (United States)

    Scott, Pat; Asplund, Martin; Grevesse, Nicolas; Sauval, A. Jacques

    2009-02-01

    Determinations of the solar oxygen content relying on the neutral forbidden transition at 630 nm depend upon the nickel abundance, due to a Ni I blend. Here, we rederive the solar nickel abundance, using the same ab initio three-dimensional hydrodynamic model of the solar photosphere employed in the recent revision of the abundances of C, N, O, and other elements. Using 17 weak, unblended lines of Ni I together with the most accurate atomic and observational data available, we find log epsilonNi = 6.17 ± 0.02(statistical) ± 0.05(systematic), a downward shift of 0.06-0.08 dex relative to previous abundances based on one-dimensional model atmospheres. We investigate the implications of the new nickel abundance for studies of the solar oxygen abundance based on the [O I] 630 nm line in the quiet Sun. Furthermore, we demonstrate that the oxygen abundance implied by the recent sunspot spectropolarimetric study of Centeno & Socas-Navarro needs to be revised downward from log epsilonO = 8.86 ± 0.07 to 8.71 ± 0.10. This revision is based on the new nickel abundance, the application of the best available gf value for the 630 nm forbidden oxygen line, and a more transparent treatment of CO formation. Determinations of the solar oxygen content relying on forbidden lines now appear to converge around log epsilonO = 8.7.

  18. Extracorporeal membrane oxygenation circuitry.

    Science.gov (United States)

    Lequier, Laurance; Horton, Stephen B; McMullan, D Michael; Bartlett, Robert H

    2013-06-01

    The extracorporeal membrane oxygenation circuit is made of a number of components that have been customized to provide adequate tissue oxygen delivery in patients with severe cardiac and/or respiratory failure for a prolonged period of time (days to weeks). A standard extracorporeal membrane oxygenation circuit consists of a mechanical blood pump, gas-exchange device, and a heat exchanger all connected together with circuit tubing. Extracorporeal membrane oxygenation circuits can vary from simple to complex and may include a variety of blood flow and pressure monitors, continuous oxyhemoglobin saturation monitors, circuit access sites, and a bridge connecting the venous access and arterial infusion limbs of the circuit. Significant technical advancements have been made in the equipment available for short- and long-term extracorporeal membrane oxygenation applications. Contemporary extracorporeal membrane oxygenation circuits have greater biocompatibility and allow for more prolonged cardiopulmonary support time while minimizing the procedure-related complications of bleeding, thrombosis, and other physiologic derangements, which were so common with the early application of extracorporeal membrane oxygenation. Modern era extracorporeal membrane oxygenation circuitry and components are simpler, safer, more compact, and can be used across a wide variety of patient sizes from neonates to adults.

  19. Plants and Oxygen

    NARCIS (Netherlands)

    Bailey-Serres, J.N.

    2009-01-01

    In this oratie I will first consider the fundamental nature of oxygen and its role within the plant cell and then will summarize studies on the cellular low-oxygen response that are interwoven with international efforts to provide farmers with rice that endures prolonged periods of complete

  20. Oxygen therapy - infants

    Science.gov (United States)

    ... may not work well and may die. Your baby may not grow properly. Many of the developing organs, including the brain and heart, may be injured. Too much oxygen can also cause injury. Breathing too much oxygen can damage the lung. ...

  1. Structural properties of oxygenated amorphous cadmium telluride thin films

    Energy Technology Data Exchange (ETDEWEB)

    El Azhari, M.Y. [Laboratoire de Physique des Solides et des Couches Minces, Marakech (Morocco). Dept. de Physique; Azizan, M. [Laboratoire de Physique des Solides et des Couches Minces, Marakech (Morocco). Dept. de Physique; Bennouna, A. [Laboratoire de Physique des Solides et des Couches Minces, Marakech (Morocco). Dept. de Physique; Outzourhit, A. [Laboratoire de Physique des Solides et des Couches Minces, Marakech (Morocco). Dept. de Physique; Ameziane, E.L. [Laboratoire de Physique des Solides et des Couches Minces, Marakech (Morocco). Dept. de Physique; Brunel, M. [Laboratoire de Cristallographie, CNRS, Grenoble (France)

    1997-02-28

    Cadmium telluride (CdTe) thin films were prepared by diode radio-frequency sputtering from polycrystalline CdTe targets in an atmosphere of argon, nitrogen and oxygen. The layers prepared in the presence of nitrogen gas were amorphous and their oxygen contents increased with the partial pressure of nitrogen. The evolution of the composition of the layers as a function of the nitrogen partial pressure during deposition was followed by X-ray photoelectron spectroscopy. It is found that the oxygen is bound to both tellurium and cadmium atoms. The surface of the CdTe thin films was also studied as a function of their exposure time to a plasma containing a mixture of nitrogen and oxygen. It is found that the oxygen contents of the surface increases with increased exposure time. Also, this exposure resulted in an increase of the oxide thickness and a net decrease in the surface roughness of the films. (orig.)

  2. Removal of oxygen from silicon by electron beam melting

    Science.gov (United States)

    Noor ul Huda Khan Asghar, H. M.; Tan, Yi; Shi, Shuang; Jiang, Dachuan; Qin, Shiqiang; Liao, Jiao; Wen, Shutao; Dong, Wei; Liu, Yao

    2014-06-01

    Small amounts of multicrystalline silicon were melted in an electron beam furnace in different experimental conditions in order to investigate the oxygen evaporation behavior during the electron beam melting (EBM) process. The oxygen content level before and after EBM was determined by secondary ion mass spectroscopy. The oxygen content was reduced from 6.177 to 1.629 ppmw when silicon was melted completely at 15 kW with removal efficiency up to 73.6 %. After that, it decreased continually to <0.0517 ppmw when the refining time exceeded 600 s with a removal efficiency of more than 99.08 %. During the melting process, the evaporation rate of silicon is 1.10 × 10-5 kg/s. The loss of silicon could be reduced up to 1.7 % during oxygen removal process to a desirable figure, indicating EBM is an effective method to remove oxygen from silicon and decrease the loss of silicon.

  3. Oxygen foreshock of Mars

    Science.gov (United States)

    Yamauchi, M.; Lundin, R.; Frahm, R. A.; Sauvaud, J.-A.; Holmström, M.; Barabash, S.

    2015-12-01

    Mars Express (MEX) has operated for more than 10 years in the environment of Mars, providing solar wind ion observations from the Analyzer of Space Plasmas and Energetic Atoms experiment's Ion Mass Analyser (IMA). On 21 September 2008, MEX/IMA detected foreshock-like discrete distributions of oxygen ions at around 1 keV in the solar wind attached to the bow shock and this distribution was observed continuously up to more than 2000 km from the bow shock. Foreshock-like protons are also observed but at a shifted location from the oxygen by about 1000 km, at a slightly higher energy, and flowing in a slightly different direction than the oxygen ions. Both protons and oxygen ions are flowing anti-sunward at different angles with respect to the solar wind direction. This is the first time that a substantial amount of planetary oxygen is observed upstream of the bow shock. Although rare, this is not the only IMA observation of foreshock-like oxygen: oxygen ions are sometimes observed for a short period of time (<5 min) inside the foreshock region. These observations suggest a new escape channel for planetary ions through the acceleration in the bow shock-magnetosheath region.

  4. Oxygen dependency of germinating Brassica seeds

    Science.gov (United States)

    Park, Myoung Ryoul; Hasenstein, Karl H.

    2016-02-01

    Establishing plants in space, Moon or Mars requires adaptation to altered conditions, including reduced pressure and composition of atmospheres. To determine the oxygen requirements for seed germination, we imbibed Brassica rapa seeds under varying oxygen concentrations and profiled the transcription patterns of genes related to early metabolism such as starch degradation, glycolysis, and fermentation. We also analyzed the activity of lactate dehydrogenase (LDH) and alcohol dehydrogenase (ADH), and measured starch degradation. Partial oxygen pressure (pO2) greater than 10% resulted in normal germination (i.e., protrusion of radicle about 18 hours after imbibition) but lower pO2 delayed and reduced germination. Imbibition in an oxygen-free atmosphere for three days resulted in no germination but subsequent transfer to air initiated germination in 75% of the seeds and the root growth rate was transiently greater than in roots germinated under ambient pO2. In hypoxic seeds soluble sugars degraded faster but the content of starch after 24 h was higher than at ambient oxygen. Transcription of genes related to starch degradation, α-amylase (AMY) and Sucrose Synthase (SUS), was higher under ambient O2 than under hypoxia. Glycolysis and fermentation pathway-related genes, glucose phosphate isomerase (GPI), 6-phosphofructokinase (PFK), fructose 1,6-bisphosphate aldolase (ALD), glyceraldehyde-3-phosphate dehydrogenase (GAPDH), pyruvate decarboxylase (PDC), LDH, and ADH, were induced by low pO2. The activity of LDH and ADH was the highest in anoxic seeds. Germination under low O2 conditions initiated ethanolic fermentation. Therefore, sufficient oxygen availability is important for germination before photosynthesis provides necessary oxygen and the determination of an oxygen carrying capacity is important for uniform growth in space conditions.

  5. Central oxygen pipeline failure

    African Journals Online (AJOL)

    Anaesthetic and critical care staff play a governing role in the comprehension of a ... complete central oxygen pipeline failure occurred throughout. Tygerberg Hospital. ..... emergency stations and at plant room emergency supply manifolds.

  6. High Selectivity Oxygen Delignification

    Energy Technology Data Exchange (ETDEWEB)

    Lucian A. Lucia

    2005-11-15

    Project Objective: The objectives of this project are as follows: (1) Examine the physical and chemical characteristics of a partner mill pre- and post-oxygen delignified pulp and compare them to lab generated oxygen delignified pulps; (2) Apply the chemical selectivity enhancement system to the partner pre-oxygen delignified pulps under mill conditions (with and without any predetermined amounts of carryover) to determine how efficiently viscosity is preserved, how well selectivity is enhanced, if strength is improved, measure any yield differences and/or bleachability differences; and (3) Initiate a mill scale oxygen delignification run using the selectivity enhancement agent, collect the mill data, analyze it, and propose any future plans for implementation.

  7. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    la Cour, M; Kiilgaard, Jens Folke; Eysteinsson, T

    2000-01-01

    To investigate the influence of acute changes in intraocular pressure on the oxygen tension in the vicinity of the optic nerve head under control conditions and after intravenous administration of 500 mg of the carbonic anhydrase inhibitor dorzolamide....

  8. 游泳运动员短时间高强度间歇训练中肌氧含量及相关指标的变化特征%Characteristics of Changes in Muscle Oxygen Content and the Related Indexes During High Intensity Interval Training

    Institute of Scientific and Technical Information of China (English)

    陈万; 田诗彬; 刘倩; 张晓辉; 黄超; 刘振宇; 李岳

    2015-01-01

    Purpose:The paper is to explore the characteristics and regular patterns of dynamic changes of muscle oxy-gen content during high intensity interval training in swimmers and to analyze the correlation of blood lactic acid ( LA) , heart rate ( HR) , ratings of perceived exertion ( RPE) before and after the training. Methods: Swim-mers ( n=15 ) from Shandong province were selected randomly for moderate intensity -intermittent mode -training. Each subject was instructed to step on cycle ergometer with all his effort for 30s, then a rest for 120s, and this behavior was repeated 3 times (3 repetitions=1 session, all together 2 sessions, the resting time be-tween both sessions was 180-240s). Muscle oxygen parameters of vastus lateralis in subjects were continuous-ly monitored;RPE and HR were collected at the end of each 30s cycling;10μl blood sample from fingertip for LA testing was collected before and after the training. Results:(1) During each 30s cycling, the oxygenated haemoglobin content ( CHbO2 ) and oxygen saturation in local tissue ( TOI) of vastus lateralis both decreased sharply, while the reduced hemoglobin (CHb) increased quickly;(2) For both sessions, the levels of LA, HR and RPE post-training were higher than those pre-training respectively (p<0. 01); (3) There were high correlations between LA, HR and RPE before and after training respectively (p <0. 01). Conclusion: (1) Near Infrared Spectroscopy could be used continuously and noninvasively in real time to monitor the dynamic changes of TOI, CHbO2 and CHb of working muscles, which reflected the training effect during training ses-sion;(2) For the individual high intensity interval training, LA, HR and RPE are effective indicators for moni-toring the training session.%目的::探讨游泳运动员短时间高强度间歇训练过程中肌肉氧参数动态变化特征和规律,以及训练前后的血乳酸( LA)、心率( HR)、主观疲劳感觉( RPE)变化及相关性。方法:随机选

  9. Southern Ocean biological impacts on global ocean oxygen

    Science.gov (United States)

    Keller, David P.; Kriest, Iris; Koeve, Wolfgang; Oschlies, Andreas

    2016-06-01

    Southern Ocean (SO) physical and biological processes are known to have a large impact on global biogeochemistry. However, the role that SO biology plays in determining ocean oxygen concentrations is not completely understood. These dynamics are investigated here by shutting off SO biology in two marine biogeochemical models. The results suggest that SO biological processes reduce the ocean's oxygen content, mainly in the deep ocean, by 14 to 19%. However, since these processes also trap nutrients that would otherwise be transported northward to fuel productivity and subsequent organic matter export, consumption, and the accompanying oxygen consumption in midlatitude to low-latitude waters, SO biology helps to maintain higher oxygen concentrations in these subsurface waters. Thereby, SO biology can influence the size of the tropical oxygen minimum zones. As a result of ocean circulation the link between SO biological processes and remote oxygen changes operates on decadal to centennial time scales.

  10. De-oxygenation

    Digital Repository Service at National Institute of Oceanography (India)

    Naqvi, S.W.A.; Kortzinger, A.

    to expand and intensify, associated with human-driven global warming. Oxygen depletion in coastal waters is also increasing in many parts of the world, related to nutrient enrichment.  Although some species can tolerate low oxygen levels, most marine... Events. By contrast, OMZs were stronger during the warm Dansgaard-Oeschger Events (Schulz et al., 1998). Human influences Among the changes that human activities are now bringing about in the marine physico-chemical environment is the general loss...

  11. Continuous home oxygen therapy.

    Science.gov (United States)

    Ortega Ruiz, Francisco; Díaz Lobato, Salvador; Galdiz Iturri, Juan Bautista; García Rio, Francisco; Güell Rous, Rosa; Morante Velez, Fátima; Puente Maestu, Luis; Tàrrega Camarasa, Julia

    2014-05-01

    Oxygen therapy is defined as the therapeutic use of oxygen and consists of administering oxygen at higher concentrations than those found in room air, with the aim of treating or preventing hypoxia. This therapeutic intervention has been shown to increase survival in patients with chronic obstructive pulmonary disease (COPD) and respiratory failure. Although this concept has been extended by analogy to chronic respiratory failure caused by respiratory and non-respiratory diseases, continuous oxygen therapy has not been shown to be effective in other disorders. Oxygen therapy has not been shown to improve survival in patients with COPD and moderate hypoxaemia, nor is there consensus regarding its use during nocturnal desaturations in COPD or desaturations caused by effort. The choice of the oxygen source must be made on the basis of criteria such as technical issues, patient comfort and adaptability and cost. Flow must be adjusted to achieve appropriate transcutaneous oxyhaemoglobin saturation correction. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  12. Normalization of oxygen and hydrogen isotope data

    Science.gov (United States)

    Coplen, T.B.

    1988-01-01

    To resolve confusion due to expression of isotopic data from different laboratories on non-corresponding scales, oxygen isotope analyses of all substances can be expressed relative to VSMOW or VPDB (Vienna Peedee belemnite) on scales normalized such that the ??18O of SLAP is -55.5% relative to VSMOW. H3+ contribution in hydrogen isotope ratio analysis can be easily determined using two gaseous reference samples that differ greatly in deuterium content. ?? 1988.

  13. The role of oxygen in quinternary superconductors.

    Energy Technology Data Exchange (ETDEWEB)

    Beckman, D.R.; Jamieson, D.N. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    The oxygen composition of the new generation of high temperature superconductors (HTSC) has been found to play a crucial role in determining the superconductivity of these materials. However, measurement of the oxygen stoichiometry in such samples has proven difficult due to the small scattering cross section of oxygen, a light element, which has caused the oxygen scattering signal to be overwhelmed by the far larger signals generated off the heavier elements present in the HTSC samples. It is for this reason that previous ion beam analysis of oxide crystals has often either made no attempt to determine the oxygen content or has used O({alpha},{alpha})O resonances such as that at {approx} 3.05 MeV to probe the crystal. This work continues tests of a new technique for probing oxygen which overcomes the problem of an insignificant O BS signal by exploiting the large nuclear resonance found to occur in the O(p,p)O cross-section near an energy of 3.5 MeV in order to produce a significant oxygen edge in the H{sup +} BS spectrum obtained for the HTSC sample. The use of a H{sup +} beam is preferable to a He{sup 2+} beam for such work due to its enhanced sensitivity to light elements. The quinternary superconductor used for this investigation was a good quality pure Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+x} (BISCO, 2212) crystal. The size of this crystal was 5x5xl mm{sup 3} with the [001] face perpendicular to the surface. Measurements were performed using the University of Melbourne nuclear microprobe. The sample was mounted on an aluminium target holder using a carbon base adhesive which provided good electrical contact and it was oriented inside the target chamber by means of a four axis precision eucentric goniometer. 6 refs., 3 figs.

  14. Venous oxygen saturation.

    Science.gov (United States)

    Hartog, Christiane; Bloos, Frank

    2014-12-01

    Early detection and rapid treatment of tissue hypoxia are important goals. Venous oxygen saturation is an indirect index of global oxygen supply-to-demand ratio. Central venous oxygen saturation (ScvO2) measurement has become a surrogate for mixed venous oxygen saturation (SvO2). ScvO2 is measured by a catheter placed in the superior vena cava. After results from a single-center study suggested that maintaining ScvO2 values >70% might improve survival rates in septic patients, international practice guidelines included this target in a bundle strategy to treat early sepsis. However, a recent multicenter study with >1500 patients found that the use of central hemodynamic and ScvO2 monitoring did not improve long-term survival when compared to the clinical assessment of the adequacy of circulation. It seems that if sepsis is recognized early, a rapid initiation of antibiotics and adequate fluid resuscitation are more important than measuring venous oxygen saturation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Method to Estimate the Dissolved Air Content in Hydraulic Fluid

    Science.gov (United States)

    Hauser, Daniel M.

    2011-01-01

    In order to verify the air content in hydraulic fluid, an instrument was needed to measure the dissolved air content before the fluid was loaded into the system. The instrument also needed to measure the dissolved air content in situ and in real time during the de-aeration process. The current methods used to measure the dissolved air content require the fluid to be drawn from the hydraulic system, and additional offline laboratory processing time is involved. During laboratory processing, there is a potential for contamination to occur, especially when subsaturated fluid is to be analyzed. A new method measures the amount of dissolved air in hydraulic fluid through the use of a dissolved oxygen meter. The device measures the dissolved air content through an in situ, real-time process that requires no additional offline laboratory processing time. The method utilizes an instrument that measures the partial pressure of oxygen in the hydraulic fluid. By using a standardized calculation procedure that relates the oxygen partial pressure to the volume of dissolved air in solution, the dissolved air content is estimated. The technique employs luminescent quenching technology to determine the partial pressure of oxygen in the hydraulic fluid. An estimated Henry s law coefficient for oxygen and nitrogen in hydraulic fluid is calculated using a standard method to estimate the solubility of gases in lubricants. The amount of dissolved oxygen in the hydraulic fluid is estimated using the Henry s solubility coefficient and the measured partial pressure of oxygen in solution. The amount of dissolved nitrogen that is in solution is estimated by assuming that the ratio of dissolved nitrogen to dissolved oxygen is equal to the ratio of the gas solubility of nitrogen to oxygen at atmospheric pressure and temperature. The technique was performed at atmospheric pressure and room temperature. The technique could be theoretically carried out at higher pressures and elevated

  16. [Veno-venous extracorporeal oxygenation and veno-arterial extracorporeal oxygenation. Questions, answers].

    Science.gov (United States)

    Isetta, C; Lebreton, G; Janot, N; Prommenschenkel, M; Rilos, Z; Roques, F; Longrois, D

    2014-04-01

    A round table, organized by the French Society of Perfusion (Sofraperf) at the French national congress on extracorporeal circulations (Perfusion 2013), was attended by perfusionists, anaesthesiologists, intensivists and surgeons around the theme of respiratory veno-venous support and veno-arterial circulatory support with extracorporeal oxygenation in intensive care units. The debate was conducted in a participatory manner by bi-directional questions-answers session between moderators and assistance. The authors report management of this type of therapy that is not perfectly homogeneous, supported on literature data. Cannulae, cannulation, circuit, oxygenator, anticoagulation, control, surveillance, weaning are subject to paragraphs with defined entry whose contents are mutually enriching.

  17. Enhanced gas sensing performance of Li-doped ZnO nanoparticle film by the synergistic effect of oxygen interstitials and oxygen vacancies

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jianwei; Xie, Changsheng, E-mail: csxie@mail.hust.edu.cn; Yang, Li; Zhang, Shunping; Zhang, Guozhu; Cai, Ziming

    2015-03-01

    Highlights: • Lithium can enhance the sensing performance of ZnO. • The effects of Li doping were investigated using temperature dependent conductivity measurements. • Li doped ZnO can induce two forms of oxygen defects: oxygen vacancies and oxygen interstitials. • The synergistic effect of oxygen vacancies and oxygen interstitials is responsible for the sensing performance enhancement of Li doped ZnO. - Abstract: Li doped ZnO (Zn{sub 1−x}Li{sub x}O) nanoparticles with different content were synthesized. X-ray photoelectron spectroscopy (XPS) indicated that the ratio of oxygen to zinc for ZnO increased with increasing of Li content from x = 0 to 0.2, which had been attributed to the introduction of oxygen interstitial by Li dopant. The sensing performance and the temperature-dependent conductivity were investigated. It is observed that Li doped ZnO showed higher sensitivity and selectivity compared to the undoped ZnO. The 0.1 Li doped ZnO performed the maximum responses of 71.5 and 40.2 for 100 ppm methanol and formaldehyde, respectively, at 350 °C. The research showed that the oxygen vacancies served as active sites which supported the oxygen adsorption and reaction, oxygen interstitials served as active sites to oxidize the reducing gases and produce electrons. The enhanced sensing performance of Li doped ZnO was attributed to the synergistic effect of oxygen interstitials and oxygen vacancies.

  18. Oxygen ion conductors

    Directory of Open Access Journals (Sweden)

    Stephen J Skinner

    2003-03-01

    A very interesting subgroup of this class of materials are the oxides that display oxygen ion conductivity. As well as the intrinsic interest in these materials, there has been a continued drive for their development because of the promise of important technological devices such as the solid oxide fuel cell (SOFC, oxygen separation membranes, and membranes for the conversion of methane to syngas1. All of these devices offer the potential of enormous commercial and ecological benefits provided suitable high performance materials can be developed. In this article we will review the materials currently under development for application in such devices with particular reference to some of the newly discovered oxide ion conductors.

  19. Neurological oxygen toxicity.

    Science.gov (United States)

    Farmery, Scott; Sykes, Oliver

    2012-10-01

    SCUBA diving has several risks associated with it from breathing air under pressure--nitrogen narcosis, barotrauma and decompression sickness (the bends). Trimix SCUBA diving involves regulating mixtures of nitrogen, oxygen and helium in an attempt to overcome the risks of narcosis and decompression sickness during deep dives, but introduces other potential hazards such as hypoxia and oxygen toxicity convulsions. This study reports on a seizure during the ascent phase, its potential causes and management and discusses the hazards posed to the diver and his rescuer by an emergency ascent to the surface.

  20. Cerebral oxygenation after birth

    DEFF Research Database (Denmark)

    Hessel, Trine W; Hyttel-Sorensen, Simon; Greisen, Gorm

    2014-01-01

    AIM: To compare absolute values of regional cerebral tissue oxygenation (cStO2 ) during haemodynamic transition after birth and repeatability during steady state for two commercial near-infrared spectroscopy (NIRS) devices. METHODS: In a prospective observational study, the INVOS 5100C and FORE......: The INVOS and FORE-SIGHT cStO2 estimates showed oxygenation-level-dependent difference during birth transition. The better repeatability of FORE-SIGHT could be due to the lower response to change in saturation....

  1. Hyperbaric Oxygen Therapy

    Science.gov (United States)

    ... hyperbaric oxygen therapy include serious infections, bubbles of air in your blood vessels, and wounds that won't heal as a ... following conditions: Anemia, severe Brain abscess Bubbles of air in your blood vessels (arterial gas embolism) Burn Decompression sickness Carbon monoxide ...

  2. Extracorporeal membrane oxygenation (ECMO)

    African Journals Online (AJOL)

    and described a 24-year-old who had sustained blunt thoracic trauma that was successfully treated using ECMO.[1] Thereafter, the first randomised, prospective study of ECMO in severe acute respiratory ... received conventional mechanical ventilation (CMV) or CMV plus ... artery, brain oxygenation cannot be guaranteed.

  3. Oxygenated Derivatives of Hydrocarbons

    Science.gov (United States)

    For the book entitled “Insect Hydrocarbons: Biology, Biochemistry and Chemical Ecology”, this chapter presents a comprehensive review of the occurrence, structure and function of oxygenated derivatives of hydrocarbons. The book chapter focuses on the occurrence, structural identification and functi...

  4. Aircraft Oxygen Generation

    Science.gov (United States)

    2012-02-01

    aircraft use some form of on-board oxygen generation provided by one of two corporations that dominate this market . A review of safety incident data...manufacture of synthetic resins (e.g., Bakelite), and for 161 making dyestuffs, flavorings, perfumes , and other chemicals. Some are used as

  5. Hybrid Oxygen System

    Science.gov (United States)

    1992-10-01

    otherwise in any manner construed, as licensing the holder or any other person or corporation ; or as conveying any rights or permission to manufacture, use...12 Modest Activity 2 12 24 Comnat ane G’s Average 5 32 64 Peak Activity (NATO) 10 50 Instantaneous Peak Flow N/A 150-20W_ Published oxygen flow rates

  6. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Pedersen, D B; Eysteinsson, T

    2004-01-01

    The authors have previously reported that carbonic anhydrase inhibitors such as acetazolamide and dorzolamide raise optic nerve oxygen tension (ONPO(2)) in pigs. The purpose of the present study was to investigate whether timolol, which belongs to another group of glaucoma drugs called beta...

  7. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Pedersen, D B; Eysteinsson, T

    2004-01-01

    The authors have previously reported that carbonic anhydrase inhibitors such as acetazolamide and dorzolamide raise optic nerve oxygen tension (ONPO(2)) in pigs. The purpose of the present study was to investigate whether timolol, which belongs to another group of glaucoma drugs called beta block...

  8. Oxygen Extraction from Minerals

    Science.gov (United States)

    Muscatello, Tony

    2017-01-01

    Oxygen, whether used as part of rocket bipropellant or for astronaut life support, is a key consumable for space exploration and commercialization. In Situ Resource Utilization (ISRU) has been proposed many times as a method for making space exploration more cost effective and sustainable. On planetary and asteroid surfaces the presence of minerals in the regolith that contain oxygen is very common, making them a potential oxygen resource. The majority of research and development for oxygen extraction from minerals has been for lunar regolith although this work would generally be applicable to regolith at other locations in space. This presentation will briefly survey the major methods investigated for oxygen extraction from regolith with a focus on the current status of those methods and possible future development pathways. The major oxygen production methods are (1) extraction from lunar ilmenite (FeTiO3) with either hydrogen or carbon monoxide, (2) carbothermal reduction of iron oxides and silicates with methane, and (3) molten regolith electrolysis (MRE) of silicates. Methods (1) and (2) have also been investigated in a two-step process using CO reduction and carbon deposition followed by carbothermal reduction. All three processes have byproducts that could also be used as resources. Hydrogen or carbon monoxide reduction produce iron metal in small amounts that could potentially be used as construction material. Carbothermal reduction also makes iron metal along with silicon metal and a glass with possible applications. MRE produces iron, silicon, aluminum, titanium, and glass, with higher silicon yields than carbothermal reduction. On Mars and possibly on some moons and asteroids, water is present in the form of mineral hydrates, hydroxyl (-OH) groups on minerals, andor water adsorbed on mineral surfaces. Heating of the minerals can liberate the water which can be electrolyzed to provide a source of oxygen as well. The chemistry of these processes, some key

  9. Pulverized fuel-oxygen burner

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Curtis; Patterson, Brad; Perdue, Jayson

    2017-09-05

    A burner assembly combines oxygen and fuel to produce a flame. The burner assembly includes an oxygen supply tube adapted to receive a stream of oxygen and a solid fuel conduit arranged to extend through the oxygen tube to convey a stream of fluidized, pulverized, solid fuel into a flame chamber. Oxygen flowing through the oxygen supply tube passes generally tangentially through a first set of oxygen-injection holes formed in the solid fuel conduit and off-tangentially from a second set of oxygen-injection holes formed in the solid fuel conduit and then mixes with fluidized, pulverized, solid fuel passing through the solid fuel conduit to create an oxygen-fuel mixture in a downstream portion of the solid fuel conduit. This mixture is discharged into a flame chamber and ignited in the flame chamber to produce a flame.

  10. The history of extracorporeal oxygenators.

    Science.gov (United States)

    Lim, M W

    2006-10-01

    Extracorporeal oxygenators are artificial devices that substitute for anatomical lungs by delivering oxygen to, and extracting carbon dioxide from, blood. They were first conceptualised by the English scientist Robert Hooke (1635-1703) and developed into practical extracorporeal oxygenators by French and German experimental physiologists in the 19th century. Indeed, most of the extracorporeal oxygenators used until the late 1970s were derived from von Schroder's 1882 bubble oxygenator and Frey and Gruber's 1885 film oxygenator. As there is no intervening barrier between blood and oxygen, these are called 'direct contact' oxygenators; they contributed significantly to the development and practice of cardiac surgery till the 1980s. Membrane extracorporeal oxygenators introduce a gas-permeable interface between blood and oxygen. This greatly decreased the blood trauma of direct-contact extracorporeal oxygenators, and enabled extracorporeal oxygenators to be used in longer-term applications such as the intensive therapy of respiratory distress syndrome; this was demonstrably beneficial for neonates but less so for older patients. Much work since the 1960s focused on overcoming the gas exchange handicap of the membrane barrier, leading to the development of high-performance microporous hollow-fibre oxygenators that eventually replaced direct-contact oxygenators in cardiac theatres.

  11. Oxygen treatment of cluster headache

    DEFF Research Database (Denmark)

    Petersen, Anja S; Barloese, Mads C J; Jensen, Rigmor H

    2014-01-01

    of oxygen treatment. One study is observational and the remaining five are RCTs. Another five studies were on hyperbaric oxygen treatment hereof two case studies. CONCLUSION: Oxygen therapy can be administered at different flow rates. Three studies investigate the effect of low-flow oxygen, 6-7 l....../min, and found a positive response in 56%, 75% and 82%, respectively, of the patients. One study investigates high-flow oxygen, 12 l/min, and found efficacy in 78% of attacks. The effect of hyperbaric oxygen therapy has been investigated in a few small studies and there is evidence only for an acute...

  12. Oxidative processes in soybean and pea seeds: effect of light, temperature, and water content

    Science.gov (United States)

    Vertucci, C. W.; Leopold, A. C.

    1987-01-01

    Oxidative processes are probable determinants of longevity of seeds in storage. Measurements of actual oxygen uptake rates were made for soybean and pea seeds as a comparison of short and long lived seeds when light, temperature, and moisture contents were varied. In both peas and soybeans, the oxygen uptake was depressed at low temperatures (water contents (water contents and at temperatures greater than 22 degrees C are much less. Light enhances the level of oxygen uptake in pea, but reduces the level of oxygen uptake in soybean. The complexities of the interactions of oxygen uptake with environmental conditions in soybean compared to pea suggest that oxidative processes occur in soybean at low water contents, but are essentially absent in pea. It is suggested that the additional oxidative processes in soybean with moisture contents between 0.10 and 0.24 gram per gram may contribute to the poorer longevity of soybean seed compared to pea seed.

  13. THE OXYGEN REGIME OF A SHALLOW LAKE

    Directory of Open Access Journals (Sweden)

    Galina Zdorovennova

    2016-01-01

    Full Text Available The year-round measurement data of water temperature and dissolved oxygen content in a small boreal Lake Vendyurskoe in 2007–2013 were used to explore the hydrophysical prerequisits of anoxia and accumulation and emission of greenhouse gases. Typically, anoxia appears in the bottom layers of lakes in mid-winter and during the summer  stagnation. The thickness of the benthic anaerobic zone (dissolved oxygen concentration <2 mg·l–1 reached one meter in the end of the winter and at the peak of the summer stratification, except for the extremely hot summer of 2010, when it reached five meters. Synoptic conditions had a crucial influence on the formation and destruction of the benthic anaerobic zones in summer. The most favorable oxygen dynamics was observed during the cold summers of 2008, 2009, and 2012, when the repeated full mixings of the water column occurred under conditions of the cyclonic weather. In the winter periods, the early dates of ice season resulted in the most pronounced deficiency of oxygen.

  14. Effects of acetazolamide on cerebral blood flow and brain tissue oxygenation

    DEFF Research Database (Denmark)

    Lassen, N A; Friberg, L; Kastrup, J

    1987-01-01

    decreased gradually to 70% of the control value, indicating hyperventilation. At sea level hyperventilation will not increase brain oxygenation significantly in normal man, as the arterial oxygen content only increases minimally, while CBF is unchanged. At high altitude the beneficial effects...... of acetazolamide on the symptoms of acute mountain sickness may well be due to an improved oxygen supply to the brain, as hyperventilation will, at the low ambient PO2, cause a significant increase of the arterial oxygen content, while CBF presumably is unaffected by the drug. During hypoxia at high altitude...

  15. Digital Content Strategies

    OpenAIRE

    Daniel Halbheer; Florian Stahl; Oded Koenigsberg; Lehmann, Donald R

    2013-01-01

    This paper studies content strategies for online publishers of digital information goods. It examines sampling strategies and compares their performance to paid content and free content strategies. A sampling strategy, where some of the content is offered for free and consumers are charged for access to the rest, is known as a "metered model" in the newspaper industry. We analyze optimal decisions concerning the size of the sample and the price of the paid content when sampling serves the dua...

  16. Oxygen Transport Ceramic Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay; T. Nithyanantham; X.-D Zhou; Y-W. Sin; H.U. Anderson; Alan Jacobson; C.A. Mims

    2005-08-01

    The present quarterly report describes some of the investigations on the structural properties of dense OTM bars provided by Praxair and studies on newer composition of Ti doped LSF. In the previous research, the reference point of oxygen occupancy was determined and verified. In the current research, the oxygen occupancy was investigated at 1200 C as a function of oxygen activity and compared with that at 1000 C. The cause of bumps at about 200 C was also investigated by using different heating and cooling rates during TGA. The fracture toughness of LSFT and dual phase membranes at room temperature is an important mechanical property. Vicker's indentation method was used to evaluate this toughness. Through this technique, a K{sub Ic} (Mode-I Fracture Toughness) value is attained by means of semi-empirical correlations between the indentation load and the length of the cracks emanating from the corresponding Vickers indentation impression. In the present investigation, crack propagation behavior was extensively analyzed in order to understand the strengthening mechanisms involved in the non-transforming La based ceramic composites. Cracks were generated using Vicker's indenter and used to identify and evaluate the toughening mechanisms involved. Preliminary results of an electron microscopy study of the origin of the slow kinetics on reduction of ferrites have been obtained. The slow kinetics appear to be related to a non-equilibrium reduction pathway that initially results in the formation of iron particles. At long times, equilibrium can be reestablished with recovery of the perovskite phase. Modeling of the isotopic transients on operating membranes (LSCrF-2828 at 900 C) and a ''frozen'' isotope profile have been analyzed in conjunction with a 1-D model to reveal the gradient in oxygen diffusivity through the membrane under conditions of high chemical gradients.

  17. Oxygen Transport Ceramic Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay; T. Nithyanantham; X.-D Zhou; Y-W. Sin; H.U. Anderson; Alan Jacobson; C.A. Mims

    2005-02-01

    The present quarterly report describes some of the investigations on the structural properties of dense OTM bars provided by Praxair and studies on newer composition of Ti doped LSF. The in situ electrical conductivity and Seebeck coefficient measurements were made on LSFT at 1000 and 1200 C over the oxygen activity range from air to 10{sup -15} atm. The electrical conductivity measurements exhibited a p to n type transition at an oxygen activity of 1 x 10{sup -10} at 1000 C and 1 x 10{sup -6} at 1200 C. Thermogravimetric studies were also carried out over the same oxygen activities and temperatures. Based on the results of these measurements, the chemical and mechanical stability range of LSFT were determined and defect structure was established. The studies on the fracture toughness of the LSFT and dual phase membranes exposed to air and N{sub 2} at 1000 C was done and the XRD and SEM analysis of the specimens were carried out to understand the structural and microstructural changes. The membranes that are exposed to high temperatures at an inert and a reactive atmosphere undergo many structural and chemical changes which affect the mechanical properties. A complete transformation of fracture behavior was observed in the N{sub 2} treated LSFT samples. Further results to investigate the origin of the slow kinetics on reduction of ferrites have been obtained. The slow kinetics appear to be related to a non-equilibrium reduction pathway that initially results in the formation of iron particles. At long times, equilibrium can be reestablished with recovery of the perovskite phase. Recent results on transient kinetic data are presented. The 2-D modeling of oxygen movement has been undertaken in order to fit isotope data. The model is used to study ''frozen'' profiles in patterned or composite membranes.

  18. Evolution of Oxygenic Photosynthesis

    Science.gov (United States)

    Fischer, Woodward W.; Hemp, James; Johnson, Jena E.

    2016-06-01

    The origin of oxygenic photosynthesis was the most important metabolic innovation in Earth history. It allowed life to generate energy and reducing power directly from sunlight and water, freeing it from the limited resources of geochemically derived reductants. This greatly increased global primary productivity and restructured ecosystems. The release of O2 as an end product of water oxidation led to the rise of oxygen, which dramatically altered the redox state of Earth's atmosphere and oceans and permanently changed all major biogeochemical cycles. Furthermore, the biological availability of O2 allowed for the evolution of aerobic respiration and novel biosynthetic pathways, facilitating much of the richness we associate with modern biology, including complex multicellularity. Here we critically review and synthesize information from the geological and biological records for the origin and evolution of oxygenic photosynthesis. Data from both of these archives illustrate that this metabolism first appeared in early Paleoproterozoic time and, despite its biogeochemical prominence, is a relatively late invention in the context of our planet's history.

  19. Oxygen-Methane Thruster Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Orion Propulsion, Inc. proposes to develop an Oxygen and Methane RCS Thruster to advance the technology of alternate fuels. A successful Oxygen/CH4 RCS Thruster will...

  20. Extra-corporeal membrane oxygenation

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007234.htm Extracorporeal membrane oxygenation To use the sharing features on this page, please enable JavaScript. Extracorporeal membrane oxygenation (ECMO) is a treatment that uses a ...

  1. LOG DURATION EMERGENCY OXYGEN BACKPACK.

    Science.gov (United States)

    A small backpack , for use by Naval aviators, containing a long duration emergency oxygen system and a separate humidifier for the aircraft’s oxygen supply, has been devised and a feasibility model built. (Author)

  2. Study on Oxygen Potential of Ferromanganese Melt during Desiliconization

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The oxygen potential of ferromanganese melt can be measured by oxygen concentration cell using ZrO2 solid electrolyte stabilized by CaO (Mo-MoO2 as contrast electrode). The converted formula of oxygen potential and electromotive force is as follows: ln pO2=20.03-(69 548.8+46 427.7×E)/T. The temperature of desiliconization is 1 350 ℃. BF ferromanganese was desiliconized by the flux 1 which contents of BaCO3, MnO2 and (Fe2O3+CaF2) are 70 %, 5 % and 25 % respectively. When the treatment time is 15 min, Fe2O3 content is 12 % for obtaining maximum rate of desiliconization. The relation of oxygen potential and activity of carbon is as follows: pO2,m/TPa=35.812-0.106×aC. The relation of oxygen potential and manganese loss is as follows: pO2,m/TPa=6.238+0.679×ΔW[Mn]. When the flux 2 which contents of BaCO3, MnO2, BaF2 and Fe2O3 are 60 %, 15 %, 10 % and 15 % respectively is used to desiliconize ferromanganese, the time corresponding to maximum rate of desiliconizaion and maximum oxygen potential is 15 min. The experimental results show that oxygen potential is controlled by C-O reaction, and that oxygen potential for desiliconization and protecting manganese are 6.238 TPa.

  3. Analysis of intra-genomic GC content homogeneity within prokaryotes

    Directory of Open Access Journals (Sweden)

    Bohlin Jon

    2010-08-01

    Full Text Available Abstract Background Bacterial genomes possess varying GC content (total guanines (Gs and cytosines (Cs per total of the four bases within the genome but within a given genome, GC content can vary locally along the chromosome, with some regions significantly more or less GC rich than on average. We have examined how the GC content varies within microbial genomes to assess whether this property can be associated with certain biological functions related to the organism's environment and phylogeny. We utilize a new quantity GCVAR, the intra-genomic GC content variability with respect to the average GC content of the total genome. A low GCVAR indicates intra-genomic GC homogeneity and high GCVAR heterogeneity. Results The regression analyses indicated that GCVAR was significantly associated with domain (i.e. archaea or bacteria, phylum, and oxygen requirement. GCVAR was significantly higher among anaerobes than both aerobic and facultative microbes. Although an association has previously been found between mean genomic GC content and oxygen requirement, our analysis suggests that no such association exits when phylogenetic bias is accounted for. A significant association between GCVAR and mean GC content was also found but appears to be non-linear and varies greatly among phyla. Conclusions Our findings show that GCVAR is linked with oxygen requirement, while mean genomic GC content is not. We therefore suggest that GCVAR should be used as a complement to mean GC content.

  4. Oxygen Transport Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay

    2008-08-30

    The focus of this research was to develop new membrane materials by synthesizing different compounds and determining their defect structures, crystallographic structures and electrical properties. In addition to measuring electrical conductivity, oxygen vacancy concentration was also evaluated using thermogravimetry, Neutron diffraction and Moessbauer Spectroscopy. The reducing conditions (CO{sub 2}/CO/H{sub 2} gas mixtures with steam) as encountered in a reactor environment can be expected to have significant influence on the mechanical properties of the oxides membranes. Various La based materials with and without Ti were selected as candidate membrane materials for OTM. The maximum electrical conductivity of LSF in air as a function of temperature was achieved at < 600 C and depends on the concentration of Sr (acceptor dopant). Oxygen occupancy in LSF was estimated using Neutron diffractometry and Moessbauer Spectroscopy by measuring magnetic moment changes depending on the Fe{sup 3+} and Fe{sup 4+} ratio. After extensive studies of candidate materials, lanthanum ferrites (LSF and LSFT) were selected as the favored materials for the oxygen transport membrane (OTM). LSF is a very good material for an OTM because of its high electronic and oxygen ionic conductivity if long term stability and mechanical strength are improved. LSFT not only exhibits p-type behavior in the high oxygen activity regime, but also has n-type conduction in reducing atmospheres. Higher concentrations of oxygen vacancies in the low oxygen activity regime may improve the performance of LSFT as an OTM. The hole concentration is related to the difference in the acceptor and donor concentration by the relation p = [Sr'{sub La}]-[Ti{sm_bullet}{sub Fe}]. The chemical formulation predicts that the hole concentration is, p = 0.8-0.45 or 0.35. Experimental measurements indicated that p is about {approx} 0.35. The activation energy of conduction is 0.2 eV which implies that LSCF conducts via the

  5. Oxygen Transport Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay

    2008-08-30

    The focus of this research was to develop new membrane materials by synthesizing different compounds and determining their defect structures, crystallographic structures and electrical properties. In addition to measuring electrical conductivity, oxygen vacancy concentration was also evaluated using thermogravimetry, Neutron diffraction and Moessbauer Spectroscopy. The reducing conditions (CO{sub 2}/CO/H{sub 2} gas mixtures with steam) as encountered in a reactor environment can be expected to have significant influence on the mechanical properties of the oxides membranes. Various La based materials with and without Ti were selected as candidate membrane materials for OTM. The maximum electrical conductivity of LSF in air as a function of temperature was achieved at < 600 C and depends on the concentration of Sr (acceptor dopant). Oxygen occupancy in LSF was estimated using Neutron diffractometry and Moessbauer Spectroscopy by measuring magnetic moment changes depending on the Fe{sup 3+} and Fe{sup 4+} ratio. After extensive studies of candidate materials, lanthanum ferrites (LSF and LSFT) were selected as the favored materials for the oxygen transport membrane (OTM). LSF is a very good material for an OTM because of its high electronic and oxygen ionic conductivity if long term stability and mechanical strength are improved. LSFT not only exhibits p-type behavior in the high oxygen activity regime, but also has n-type conduction in reducing atmospheres. Higher concentrations of oxygen vacancies in the low oxygen activity regime may improve the performance of LSFT as an OTM. The hole concentration is related to the difference in the acceptor and donor concentration by the relation p = [Sr'{sub La}]-[Ti{sm_bullet}{sub Fe}]. The chemical formulation predicts that the hole concentration is, p = 0.8-0.45 or 0.35. Experimental measurements indicated that p is about {approx} 0.35. The activation energy of conduction is 0.2 eV which implies that LSCF conducts via the

  6. Oxygen Transport Ceramic Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay; N. Nagabhushana; T. Nithyanantham; X.-D Zhou; Y-W. Sin; H.U. Anderson; Alan Jacobson; C.A. Mims

    2005-02-01

    The present quarterly report describes some of the investigations on the structural properties of dense OTM bars provided by Praxair and studies on newer composition of Ti doped LSF. Thermogravimetric analysis (TGA) was carried out on La{sub 0.2}Sr{sub 0.8}Fe{sub 0.55}Ti{sub 0.45}O{sub 3-{delta}} to investigate oxygen deficiency ({delta}) of the sample. The TGA was performed in a controlled atmosphere using oxygen, argon, carbon monoxide and carbon dioxide with adjustable gas flow rates. In this experiment, the weight loss and gain of La{sub 0.2}Sr{sub 0.8}Fe{sub 0.55}Ti{sub 0.45}O{sub 3-{delta}} was directly measured by TGA. The weight change of the sample was evaluated at between 600 and 1250 C in air or 1000 C as a function of oxygen partial pressure. The oxygen deficiencies calculated from TGA data as a function of oxygen activity and temperature will be estimated and compared with that from neutron diffraction measurement in air. The LSFT and LSFT/CGO membranes were fabricated from the powder obtained from Praxair Specialty Ceramics. The sintered membranes were subjected to microstructure analysis and hardness analysis. The LSFT membrane is composed of fine grains with two kinds of grain morphology. The grain size distribution was characterized using image analysis. In LSFT/CGO membrane a lot of grain pullout was observed from the less dense, porous phase. The hardness of the LSFT and dual phase membranes were studied at various loads. The hardness values obtained from the cross section of the membranes were also compared to that of the values obtained from the surface. An electrochemical cell has been designed and built for measurements of the Seebeck coefficient as a function of temperature and pressure. Measurements on La{sub 0.2}Sr{sub 0.8}Fe{sub 0.55}Ti{sub 0.45}O{sub 3-{delta}} as a function of temperature an oxygen partial pressure are reported. Further analysis of the dilatometry data obtained previously is presented. A series of isotope transients

  7. Mixed oxygen ion/electron-conducting ceramics for oxygen separation

    Energy Technology Data Exchange (ETDEWEB)

    Stevenson, J.W.; Armstrong, T.R.; Armstrong, B.L. [Pacific Northwest National Lab., Richland, WA (United States)

    1996-08-01

    Mixed oxygen ion and electron-conducting ceramics are unique materials that can passively separate high purity oxygen from air. Oxygen ions move through a fully dense ceramic in response to an oxygen concentration gradient, charge-compensated by an electron flux in the opposite direction. Compositions in the system La{sub 1{minus}x}M{sub x}Co{sub 1{minus}y{minus}z}Fe{sub y}N{sub z}O{sub 3{minus}{delta}}, perovskites where M=Sr, Ca, and Ba, and N=Mn, Ni, Cu, Ti, and Al, have been prepared and their electrical, oxygen permeation, oxygen vacancy equilibria, and catalytic properties evaluated. Tubular forms, disks, and asymmetric membrane structures, a thin dense layer on a porous support of the same composition, have been fabricated for testing purposes. In an oxygen partial gradient, the passive oxygen flux through fully dense structures was highly dependent on composition. An increase in oxygen permeation with increased temperature is attributed to both enhanced oxygen vacancy mobility and higher vacancy populations. Highly acceptor-doped compositions resulted in oxygen ion mobilities more than an order of magnitude higher than yttria-stabilized zirconia. The mixed conducting ceramics have been utilized in a membrane reactor configuration to upgrade methane to ethane and ethylene. Conditions were established to balance selectivity and throughput in a catalytic membrane reactor constructed from mixed conducting ceramics.

  8. Physical chemistry of corrosion and oxygen control in liquid lead and lead-bismuth eutectic

    Energy Technology Data Exchange (ETDEWEB)

    Schroer, C.; Konys, J.

    2007-12-15

    Corrosion of steel in liquid lead (Pb) and lead-bismuth eutectic (LBE) is an important factor when applying these materials as a process medium. At low oxygen content of the liquid-metal phase, the degradation results mainly from the dissolution of the steel constituents, which may significantly decrease in the presence of a continuous scale of oxides of the steel constituents on the steel surface. In order to facilitate the formation of such a scale, the oxygen content of the liquid metal has to be controlled. Therefore, a method of measuring the oxygen content must be available. This report addresses the thermodynamic fundamentals of steel corrosion in oxygen-containing liquid metals and provides the data on chemical and physical properties which is required for the determination of favourable conditions with respect to the oxygen content and the numerical analysis of the dissolution of the primary steel constituents in oxygen-containing liquid Pb and LBE. Furthermore, the measurement of the oxygen content with electrochemical oxygen sensors and the evaluation of the sensor output is discussed. (orig.)

  9. [Oxygen metabolism in the body during substitution of nitrogen by helium in the air].

    Science.gov (United States)

    Troshikhin, G V; Isaakian, L A; Bekirova, G G

    1975-01-01

    The total gas exchange, body temperature, content of free oxygen in the quadriceps muscle and its changes upon oxygen inhalation of a known dosage (oxygen test) were measured in the Wistar rats during their one-hour exposure to a helium-oxygen atmosphere (21%) at 25 degrees C. In this atmosphere the animals displayed a 1.8 degrees decline in the body temperature, a 20.5% increase in the gas exchange and a 26% decrease of oxygen in the muscular tissue as compared with the respective parameters in the air. After the experiment during the first 20 min exposure to the normal atmosphere oxygen tests were 10-15% lower than before the experiment. These findings give evidence for an increase of oxygen exchange in the muscles of animals exposed to the helium-oxygen atmosphere at a temperature below the comfortable level.

  10. Oxygenation and superconductivity of Tl2CaBa2Cu2O8- x

    Science.gov (United States)

    Wu, Nae-Lih; Chu, H. T.

    1990-05-01

    Oxygenation of Tl 2CaBa 2Cu 2O 8- x between 250°C and 800°C was studied. The curves which plotted the amount of oxygen adsorbed as a function of oxygenation temperature indicated the presence of two oxygen adsorption processes, including one which prevailed at temperature below 400°C and the other between 500°C and 700°C. When the compound was oxygenated consecutively at increasing temperatures, the Tc of the oxide first increased and then decreased, exhibiting a maximum after oxygenation at 400°C. The Tc increased almost linearly with the amounts of oxygen adsorbed below 400°C but showed no unique (one-to-one) correlation with the overall oxygen content of the oxide.

  11. Oxygen Transport Ceramic Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay; T. Nithyanantham

    2006-12-31

    Ti doping on La{sub 1-x}Sr{sub x}FeO{sub 3-{delta}} (LSF) tends to increase the oxygen equilibration kinetics of LSF in lower oxygen activity environment because of the high valence state of Ti. However, the addition of Ti decreases the total conductivity because the acceptor ([Sr{prime}{sub La}]) is compensated by the donor ([Ti{sub Fe}{sup {sm_bullet}}]) which decreases the carrier concentration. The properties of La{sub 0.2}Sr{sub 0.8}Fe{sub 1-x}Ti{sub x}O{sub 3-{delta}} (LSFT, x = 0.45) have been experimentally and theoretically investigated to elucidate (1) the dependence of oxygen occupancy and electrochemical properties on temperature and oxygen activity by thermogravimetric analysis (TGA) and (2) the electrical conductivity and carrier concentration by Seebeck coefficient and electrical measurements. In the present study, dual phase (La{sub 0.2}Sr{sub 0.8}Fe{sub 0.6}Ti{sub 0.4}O{sub 3-{delta}}/Ce{sub 0.9}Gd{sub 0.1}O{sub 2-{delta}}) membranes have been evaluated for structural properties such as hardness, fracture toughness and flexural strength. The effect of high temperature and slightly reducing atmosphere on the structural properties of the membranes was studied. The flexural strength of the membrane decreases upon exposure to slightly reducing conditions at 1000 C. The as-received and post-fractured membranes were characterized using XRD, SEM and TG-DTA to understand the fracture mechanisms. Changes in structural properties of the composite were sought to be correlated with the physiochemical features of the two-phases. We have reviewed the electrical conductivity data and stoichiometry data for La{sub 0.2}Sr{sub 0.8}Cr{sub 0.2}Fe{sub 0.8}O{sub 3-{delta}} some of which was reported previously. Electrical conductivity data for La{sub 0.2}Sr{sub 0.8}Cr{sub 0.2}Fe{sub 0.8}O{sub 3-{delta}} (LSCrF) were obtained in the temperature range, 752 {approx} 1055 C and in the pO{sub 2} range, 10{sup -18} {approx} 0.5 atm. The slope of the plot of log {sigma} vs

  12. Decreased oxygen tension lowers reactive oxygen species and apoptosis and inhibits osteoblast matrix mineralization through changes in early osteoblast differentiation.

    Science.gov (United States)

    Nicolaije, Claudia; Koedam, Marijke; van Leeuwen, Johannes P T M

    2012-04-01

    Accumulating data show that oxygen tension can have an important effect on cell function and fate. We used the human pre-osteoblastic cell line SV-HFO, which forms a mineralizing extracellular matrix, to study the effect of low oxygen tension (2%) on osteoblast differentiation and mineralization. Mineralization was significantly reduced by 60-70% under 2% oxygen, which was paralleled by lower intracellular levels of reactive oxygen species (ROS) and apoptosis. Following this reduction in ROS the cells switched to a lower level of protection by down-regulating their antioxidant enzyme expression. The downside of this is that it left the cells more vulnerable to a subsequent oxidative challenge. Total collagen content was reduced in the 2% oxygen cultures and expression of matrix genes and matrix-metabolizing enzymes was significantly affected. Alkaline phosphatase activity and RNA expression as well as RUNX2 expression were significantly reduced under 2% oxygen. Time phase studies showed that high oxygen in the first phase of osteoblast differentiation and prior to mineralization is crucial for optimal differentiation and mineralization. Switching to 2% or 20% oxygen only during mineralization phase did not change the eventual level of mineralization. In conclusion, this study shows the significance of oxygen tension for proper osteoblast differentiation, extra cellular matrix (ECM) formation, and eventual mineralization. We demonstrated that the major impact of oxygen tension is in the early phase of osteoblast differentiation. Low oxygen in this phase leaves the cells in a premature differentiation state that cannot provide the correct signals for matrix maturation and mineralization.

  13. Oxygen Isotopes in Meteorites

    Science.gov (United States)

    Clayton, R. N.

    2003-12-01

    Oxygen isotope abundance variations in meteorites are very useful in elucidating chemical and physical processes that occurred during the formation of the solar system (Clayton, 1993). On Earth, the mean abundances of the three stable isotopes are 16O: 99.76%, 17O: 0.039%, and 18O: 0.202%. It is conventional to express variations in abundances of the isotopes in terms of isotopic ratios, relative to an arbitrary standard, called SMOW (for standard mean ocean water), as follows:The isotopic composition of any sample can then be represented by one point on a "three-isotope plot," a graph of δ17O versus δ18O. It will be seen that such plots are invaluable in interpreting meteoritic data. Figure 1 shows schematically the effect of various processes on an initial composition at the center of the diagram. Almost all terrestrial materials lie along a "fractionation" trend; most meteoritic materials lie near a line of "16O addition" (or subtraction). (4K)Figure 1. Schematic representation of various isotopic processes shown on an oxygen three-isotope plot. Almost all terrestrial materials plot along a line of "fractionation"; most primitive meteoritic materials plot near a line of "16O addition." The three isotopes of oxygen are produced by nucleosynthesis in stars, but by different nuclear processes in different stellar environments. The principal isotope, 16O, is a primary isotope (capable of being produced from hydrogen and helium alone), formed in massive stars (>10 solar masses), and ejected by supernova explosions. The two rare isotopes are secondary nuclei (produced in stars from nuclei formed in an earlier generation of stars), with 17O coming primarily from low- and intermediate-mass stars (shielding in the UV photodissociation of CO (van Dishoeck and Black, 1988). This process results from the large differences in abundance between C16O, on the one hand, and C17O and C18O on the other. Photolysis of CO occurs by absorption of stellar UV radiation in the

  14. Oxygen Reduction on Platinum

    DEFF Research Database (Denmark)

    Nesselberger, Markus

    This thesis investigates the electro reduction of oxygen on platinum nanoparticles, which serve as catalyst in low temperature fuel cells. Kinetic studies on model catalysts as well as commercially used systems are presented in order to investigate the particle size effect, the particle proximity...... carbon (HSAC) supported Pt nanoparticle (Pt/C) catalysts (of various size between 1 and 5 nm). The difference in SA between the individual Pt/C catalysts (1 to 5 nm) is very small and within the error of the measurements. The factor four of loss in SA when comparing platinum bulk and Pt/C can largely...

  15. Timescales of Oxygenation Following the Evolution of Oxygenic Photosynthesis.

    Science.gov (United States)

    Ward, Lewis M; Kirschvink, Joseph L; Fischer, Woodward W

    2016-03-01

    Among the most important bioenergetic innovations in the history of life was the invention of oxygenic photosynthesis-autotrophic growth by splitting water with sunlight-by Cyanobacteria. It is widely accepted that the invention of oxygenic photosynthesis ultimately resulted in the rise of oxygen by ca. 2.35 Gya, but it is debated whether this occurred more or less immediately as a proximal result of the evolution of oxygenic Cyanobacteria or whether they originated several hundred million to more than one billion years earlier in Earth history. The latter hypothesis involves a prolonged period during which oxygen production rates were insufficient to oxidize the atmosphere, potentially due to redox buffering by reduced species such as higher concentrations of ferrous iron in seawater. To examine the characteristic timescales for environmental oxygenation following the evolution of oxygenic photosynthesis, we applied a simple mathematical approach that captures many of the salient features of the major biogeochemical fluxes and reservoirs present in Archean and early Paleoproterozoic surface environments. Calculations illustrate that oxygenation would have overwhelmed redox buffers within ~100 kyr following the emergence of oxygenic photosynthesis, a geologically short amount of time unless rates of primary production were far lower than commonly expected. Fundamentally, this result arises because of the multiscale nature of the carbon and oxygen cycles: rates of gross primary production are orders of magnitude too fast for oxygen to be masked by Earth's geological buffers, and can only be effectively matched by respiration at non-negligible O2 concentrations. These results suggest that oxygenic photosynthesis arose shortly before the rise of oxygen, not hundreds of millions of years before it.

  16. Keeping out the oxygen

    NARCIS (Netherlands)

    de Jongh, P.E.

    2011-01-01

    Hydrogen, the lightest of the elements, is expected to play a major role in our future energy economy. Its staggering energy content of 142 MJ kg-1 exceeds that of petroleum by a factor of three. Moreover, the combustion of hydrogen, as well as its use in electricity-producing fuel cells, is not ass

  17. Observer-based Coal Mill Control using Oxygen Measurements

    DEFF Research Database (Denmark)

    Andersen, Palle; Bendtsen, Jan Dimon; S., Tom;

    2006-01-01

    This paper proposes a novel approach to coal flow estimation in pulverized coal mills, which utilizes measurements of oxygen content in the flue gas. Pulverized coal mills are typically not equipped with sensors that detect the amount of coal injected into the furnace. This makes control of the c......This paper proposes a novel approach to coal flow estimation in pulverized coal mills, which utilizes measurements of oxygen content in the flue gas. Pulverized coal mills are typically not equipped with sensors that detect the amount of coal injected into the furnace. This makes control...... into the furnace and oxygen concentration in the flue gas is designed to estimate the actual coal flow injected into the furnace. With this estimate, it becomes possible to close an inner loop around the coal mill itself, thus giving a better disturbance rejection capability. The approach is validated against...

  18. OXYGEN TRANSPORT CERAMIC MEMBRANES

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Sukumar Bandopadhyay; Dr. Nagendra Nagabhushana

    2000-10-01

    This is the third quarterly report on oxygen Transport Ceramic Membranes. In the following, the report describes the progress made by our university partners in Tasks 1 through 6, experimental apparatus that was designed and built for various tasks of this project, thermodynamic calculations, where applicable and work planned for the future. (Task 1) Design, fabricate and evaluate ceramic to metal seals based on graded ceramic powder/metal braze joints. (Task 2) Evaluate the effect of defect configuration on ceramic membrane conductivity and long term chemical and structural stability. (Task 3) Determine materials mechanical properties under conditions of high temperatures and reactive atmospheres. (Task 4) Evaluate phase stability and thermal expansion of candidate perovskite membranes and develop techniques to support these materials on porous metal structures. (Task 5) Assess the microstructure of membrane materials to evaluate the effects of vacancy-impurity association, defect clusters, and vacancy-dopant association on the membrane performance and stability. (Task 6) Measure kinetics of oxygen uptake and transport in ceramic membrane materials under commercially relevant conditions using isotope labeling techniques.

  19. Composite oxygen transport membrane

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Zigui; Plonczak, Pawel J.; Lane, Jonathan A.

    2016-11-08

    A method is described of producing a composite oxygen ion membrane and a composite oxygen ion membrane in which a porous fuel oxidation layer and a dense separation layer and optionally, a porous surface exchange layer are formed on a porous support from mixtures of (Ln.sub.1-xA.sub.x).sub.wCr.sub.1-yB.sub.yO.sub.3-.delta. and a doped zirconia. Preferred materials are (La.sub.0.8Sr.sub.0.2).sub.0.95Cr.sub.0.7Fe.sub.0.3O.sub.3-.delta. for the porous fuel oxidation layer, (La.sub.0.8Sr.sub.0.2).sub.0.95Cr.sub.0.5Fe.sub.0.5O.sub.3-.delta. for the dense separation layer, and (La.sub.0.8Sr.sub.0.2).sub.0.95Cr.sub.0.3Fe.sub.0.7O.sub.3-.delta. for the porous surface exchange layer. Firing the said fuel activation and separation layers in nitrogen atmosphere unexpectedly allows the separation layer to sinter into a fully densified mass.

  20. Composite oxygen transport membrane

    Energy Technology Data Exchange (ETDEWEB)

    Christie, Gervase Maxwell; Lane, Jonathan A.

    2016-11-15

    A method of producing a composite oxygen ion membrane and a composite oxygen ion membrane in which a porous fuel oxidation layer and a dense separation layer and optionally, a porous surface exchange layer are formed on a porous support from mixtures of (Ln.sub.1-xA.sub.x).sub.wCr.sub.1-yB.sub.yO.sub.3-.delta. and a doped zirconia. In the porous fuel oxidation layer and the optional porous surface exchange layer, A is Calcium and in the dense separation layer A is not Calcium and, preferably is Strontium. Preferred materials are (La.sub.0.8Ca.sub.0.2).sub.0.95Cr.sub.0.5Mn.sub.0.5O.sub.3-.delta. for the porous fuel oxidation and optional porous surface exchange layers and (La.sub.0.8Sr.sub.0.2).sub.0.95Cr.sub.0.5Fe.sub.0.5O.sub.3-.delta. for the dense separation layer. The use of such materials allows the membrane to sintered in air and without the use of pore formers to reduce membrane manufacturing costs. The use of materials, as described herein, for forming the porous layers have application for forming any type of porous structure, such as a catalyst support.

  1. OXYGEN ABUNDANCES IN CEPHEIDS

    Energy Technology Data Exchange (ETDEWEB)

    Luck, R. E.; Andrievsky, S. M. [Department of Astronomy, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106-7215 (United States); Korotin, S. N.; Kovtyukh, V. V., E-mail: luck@fafnir.astr.cwru.edu, E-mail: serkor@skyline.od.ua, E-mail: val@deneb1.odessa.ua, E-mail: scan@deneb1.odessa.ua [Department of Astronomy and Astronomical Observatory, Odessa National University, Isaac Newton Institute of Chile, Odessa Branch, Shevchenko Park, 65014 Odessa (Ukraine)

    2013-07-01

    Oxygen abundances in later-type stars, and intermediate-mass stars in particular, are usually determined from the [O I] line at 630.0 nm, and to a lesser extent, from the O I triplet at 615.7 nm. The near-IR triplets at 777.4 nm and 844.6 nm are strong in these stars and generally do not suffer from severe blending with other species. However, these latter two triplets suffer from strong non-local thermodynamic equilibrium (NLTE) effects and thus see limited use in abundance analyses. In this paper, we derive oxygen abundances in a large sample of Cepheids using the near-IR triplets from an NLTE analysis, and compare those abundances to values derived from a local thermodynamic equilibrium (LTE) analysis of the [O I] 630.0 nm line and the O I 615.7 nm triplet as well as LTE abundances for the 777.4 nm triplet. All of these lines suffer from line strength problems making them sensitive to either measurement complications (weak lines) or to line saturation difficulties (strong lines). Upon this realization, the LTE results for the [O I] lines and the O I 615.7 nm triplet are in adequate agreement with the abundance from the NLTE analysis of the near-IR triplets.

  2. Composite oxygen transport membrane

    Science.gov (United States)

    Christie, Gervase Maxwell; Lane, Jonathan A.

    2014-08-05

    A method of producing a composite oxygen ion membrane and a composite oxygen ion membrane in which a porous fuel oxidation layer and a dense separation layer and optionally, a porous surface exchange layer are formed on a porous support from mixtures of (Ln.sub.1-xA.sub.x).sub.wCr.sub.1-yB.sub.yO.sub.3-.delta. and a doped zirconia. In the porous fuel oxidation layer and the optional porous surface exchange layer, A is Calcium and in the dense separation layer A is not Calcium and, preferably is Strontium. Preferred materials are (La.sub.0.8Ca.sub.0.2).sub.0.95Cr.sub.0.5Mn.sub.0.5O.sub.3-.delta. for the porous fuel oxidation and optional porous surface exchange layers and (La.sub.0.8Sr.sub.0.2).sub.0.95Cr.sub.0.5Fe.sub.0.5O.sub.3-.delta. for the dense separation layer. The use of such materials allows the membrane to sintered in air and without the use of pore formers to reduce membrane manufacturing costs. The use of materials, as described herein, for forming the porous layers have application for forming any type of porous structure, such as a catalyst support.

  3. Sterilization by oxygen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Adir Jose; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Silva Zambon, Luis da; Silva, Monica Valero da; Verdonck, Patrick Bernard

    2004-07-31

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  4. OXYGEN TRANSPORT CERAMIC MEMBRANES

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Sukumar Bandopadhyay; Dr. Nagendra Nagabhushana

    2000-10-01

    This is the third quarterly report on oxygen Transport Ceramic Membranes. In the following, the report describes the progress made by our university partners in Tasks 1 through 6, experimental apparatus that was designed and built for various tasks of this project, thermodynamic calculations, where applicable and work planned for the future. (Task 1) Design, fabricate and evaluate ceramic to metal seals based on graded ceramic powder/metal braze joints. (Task 2) Evaluate the effect of defect configuration on ceramic membrane conductivity and long term chemical and structural stability. (Task 3) Determine materials mechanical properties under conditions of high temperatures and reactive atmospheres. (Task 4) Evaluate phase stability and thermal expansion of candidate perovskite membranes and develop techniques to support these materials on porous metal structures. (Task 5) Assess the microstructure of membrane materials to evaluate the effects of vacancy-impurity association, defect clusters, and vacancy-dopant association on the membrane performance and stability. (Task 6) Measure kinetics of oxygen uptake and transport in ceramic membrane materials under commercially relevant conditions using isotope labeling techniques.

  5. Oxygen-Methane Thruster

    Science.gov (United States)

    Pickens, Tim

    2012-01-01

    An oxygen-methane thruster was conceived with integrated igniter/injector capable of nominal operation on either gaseous or liquid propellants. The thruster was designed to develop 100 lbf (approximately 445 N) thrust at vacuum conditions and use oxygen and methane as propellants. This continued development included refining the design of the thruster to minimize part count and manufacturing difficulties/cost, refining the modeling tools and capabilities that support system design and analysis, demonstrating the performance of the igniter and full thruster assembly with both gaseous and liquid propellants, and acquiring data from this testing in order to verify the design and operational parameters of the thruster. Thruster testing was conducted with gaseous propellants used for the igniter and thruster. The thruster was demonstrated to work with all types of propellant conditions, and provided the desired performance. Both the thruster and igniter were tested, as well as gaseous propellants, and found to provide the desired performance using the various propellant conditions. The engine also served as an injector testbed for MSFC-designed refractory combustion chambers made of rhenium.

  6. Measured and calculated variables of global oxygenation in healthy neonatal foals.

    Science.gov (United States)

    Wong, David M; Hepworth-Warren, Kate L; Sponseller, Beatrice T; Howard, Joan M; Wang, Chong

    2017-02-01

    OBJECTIVE To assess multiple central venous and arterial blood variables that alone or in conjunction with one another reflect global oxygenation status in healthy neonatal foals. ANIMALS 11 healthy neonatal foals. PROCEDURES Central venous and arterial blood samples were collected from healthy neonatal foals at 12, 24, 36, 48, 72, and 96 hours after birth. Variables measured from central venous and arterial blood samples included oxygen saturation of hemoglobin, partial pressure of oxygen, lactate concentration, partial pressure of carbon dioxide, and pH. Calculated variables included venous-to-arterial carbon dioxide gap, estimated oxygen extraction ratio, ratio of partial pressure of oxygen in arterial blood to the fraction of inspired oxygen, bicarbonate concentration, base excess, and blood oxygen content. RESULTS Significant differences between arterial and central venous blood obtained from neonatal foals were detected for several variables, particularly partial pressure of oxygen, oxygen saturation of hemoglobin, and oxygen content. In addition, the partial pressure of carbon dioxide in central venous blood samples was significantly higher than the value for corresponding arterial blood samples. Several temporal differences were detected for other variables. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study provided information about several variables that reflect global oxygenation in healthy neonatal foals. Values for these variables in healthy foals can allow for comparison with values for critically ill foals in future studies. Comparison of these variables between healthy and ill foals may aid in treatment decisions and prognosis of clinical outcome for critically ill foals.

  7. High Selectivity Oxygen Delignification

    Energy Technology Data Exchange (ETDEWEB)

    Arthur J. Ragauskas

    2005-09-30

    The overall objective of this program was to develop improved extended oxygen delignification (EOD) technologies for current U.S. pulp mill operations. This was accomplished by: (1) Identifying pulping conditions that optimize O and OO performance; (2) Identifying structural features of lignin that enhance reactivity towards EOD of high kappa pulps; (3) Identifying factors minimizing carbohydrate degradation and improve pulp strength of EOD high kappa pulps; (4) Developing a simple, reproducible method of quantifying yield gains from EOD; and (5) Developing process conditions that significantly reduce the capital requirements of EOD while optimizing the yield benefits. Key research outcomes included, demonstrating the use of a mini-O sequence such as (E+O)Dkf:0.05(E+O) or Dkf:0.05(E+O)(E+O) without interstage washing could capture approximately 60% of the delignification efficiency of a conventional O-stage without the major capital requirements associated with an O-stage for conventional SW kraft pulps. The rate of formation and loss of fiber charge during an O-stage stage can be employed to maximize net fiber charge. Optimal fiber charge development and delignification are two independent parameters and do not parallel each other. It is possible to utilize an O-stage to enhance overall cellulosic fiber charge of low and high kappa SW kraft pulps which is beneficial for physical strength properties. The application of NIR and multi-variant analysis was developed into a rapid and simple method of determining the yield of pulp from an oxygen delignification stage that has real-world mill applications. A focus point of this program was the demonstration that Kraft pulping conditions and oxygen delignification of high and low-kappa SW and HW pulps are intimately related. Improved physical pulp properties and yield can be delivered by controlling the H-factor and active alkali charge. Low AA softwood kraft pulp with a kappa number 30 has an average improvement of 2% in

  8. Fires and Burns Involving Home Medical Oxygen

    Science.gov (United States)

    ... nfpa.org Fires and Burns Involving Home Medical Oxygen The air is normally 21% oxygen. Oxygen is not flammable, but fire needs it to burn. ¾ When more oxygen is present, any fire that starts will burn ...

  9. Understanding Your Watershed Fact Sheet: Dissolved Oxygen

    OpenAIRE

    Mesner, Nancy; Geiger, John

    2010-01-01

    Dissolved oxygen describes oxygen molecules which have actually dissolved in water. Sometimes people confuse bubbles in water with dissolved oxygen, but in reality the dissolved form of oxygen cannot be seen.

  10. Interphase Evolution of a Lithium-Ion/Oxygen Battery.

    Science.gov (United States)

    Elia, Giuseppe Antonio; Bresser, Dominic; Reiter, Jakub; Oberhumer, Philipp; Sun, Yang-Kook; Scrosati, Bruno; Passerini, Stefano; Hassoun, Jusef

    2015-10-14

    A novel lithium-ion/oxygen battery employing Pyr14TFSI-LiTFSI as the electrolyte and nanostructured LixSn-C as the anode is reported. The remarkable energy content of the oxygen cathode, the replacement of the lithium metal anode by a nanostructured stable lithium-alloying composite, and the concomitant use of nonflammable ionic liquid-based electrolyte result in a new and intrinsically safer energy storage system. The lithium-ion/oxygen battery delivers a stable capacity of 500 mAh g(-1) at a working voltage of 2.4 V with a low charge-discharge polarization. However, further characterization of this new system by electrochemical impedance spectroscopy, scanning electron microscopy, and energy-dispersive X-ray spectroscopy reveals the progressive decrease of the battery working voltage, because of the crossover of oxygen through the electrolyte and its direct reaction with the LixSn-C anode.

  11. Thermodynamics of oxygen in dilute liquid silver-tellurium alloys.

    Science.gov (United States)

    Nyk, Justyna; Onderka, Bogusław

    The activity coefficient of oxygen [Formula: see text] in liquid Ag and binary Ag-Te dilute alloys were determined between 1,285 and 1,485 K by coulometric titration using the electrochemical cell (Ir, [O] in liquid metal or alloy | yttria stabilized zirconia | air, Pt). The experimental and evaluation procedures described in the literature were adopted. The oxygen activity coefficient was determined in pure liquid silver to be [Formula: see text]. Next, the oxygen activity coefficient in dilute Ag-(Te)-O alloys for variable XTe content (from 0.01 to 0.06) was measured. From the obtained results, Wagner's interaction parameter [Formula: see text] as a function of temperature was derived in the form [Formula: see text]. The electrochemical coulometric titration method seems to be very useful to study the thermodynamics of oxygen interaction in liquid silver and its alloys.

  12. POLYETHER POLYURETHANE FROM MODIFIED WHEAT STRAW OXYGEN-ALKALINE LIGNIN

    Institute of Scientific and Technical Information of China (English)

    QuanxiaoLiu; HuaiyuZhan; BeihaiHe; ShuhuiYang; JianhuaLiu; JianluLiu(1); ZhenxingPang

    2004-01-01

    Polyether polyurethane was synthesized from modified wheat straw oxygen-alkaline lignin, polyethylene glycol and two different diisocyanates (diphenylemethane-4, 4'-diisocyanate, tolulene diisocyanate) by solution casting method, its properties were investigated. The results show that modified wheat straw oxygen-alkaline lignin can substitute part of polyethylene glycol to react with diisocyanate to synthesize polyurethane. The molar ratio of NCO to OH and modified wheat straw oxygen-alkaline lignin content affect the properties of lignin-based polyether polyurethane respectively. The addition of plasticizer in the polyurethane synthesis process improves the properties of synthesized polyurethane, especially the elasticity of polyurethane. The synthesized polyurethane from modified wheat straw oxygen-alkali lignin can be used as both engineering plastic and hard foam plastic in future.

  13. POLYETHER POLYURETHANE FROM MODIFIED WHEAT STRAW OXYGEN-ALKALINE LIGNIN

    Institute of Scientific and Technical Information of China (English)

    Quanxiao Liu; Huaiyu Zhan; Beihai He; Shuhui Yang; Jianhua Liu; Jianlu Liu; Zhenxing Pang

    2004-01-01

    Polyether polyurethane was synthesized from modified wheat straw oxygen-alkaline lignin,polyethylene glycol and two different diisocyanates (diphenylemethane-4, 4′-diisocyanate, tolulene diisocyanate) by solution casting method, its properties were investigated. The results show that modified wheat straw oxygen-alkaline lignin can substitute part of polyethylene glycol to react with diisocyanate to synthesize polyurethane. The molar ratio of NCO to OH and modified wheat straw oxygen-alkaline lignin content affect the properties of lignin-based polyether polyurethane respectively. The addition of plasticizer in the polyurethane synthesis process improves the properties of synthesized polyurethane, especially the elasticity of polyurethane. The synthesized polyurethane from modified wheat straw oxygen-alkali lignin can be used as both engineering plastic and hard foam plastic in future.

  14. Effects of Oxygen Element and Oxygen-Containing Functional Groups on Surface Wettability of Coal Dust with Various Metamorphic Degrees Based on XPS Experiment.

    Science.gov (United States)

    Zhou, Gang; Xu, Cuicui; Cheng, Weimin; Zhang, Qi; Nie, Wen

    2015-01-01

    To investigate the difference of surface oxygen element and oxygen-containing functional groups among coal dusts with different metamorphic degrees and their influence on surface wettability, a series of X-ray photoelectron spectroscopy experiments on 6 coal samples are carried out. The result demonstrates that the O/C ratio of coal surface shows an overall increasing trend compared with the result of its elements analysis. As the metamorphic degree increases, the O/C ratio on the surface gradually declines and the hydrophilic groups tend to fall off from coal surface. It could be found that different coals show different surface distributions of carboxyl and hydroxyl which are considered as the greatest promoter to the wettability of coal surface. With the change of metamorphic degree, the distribution of ether group is irregular while the carbonyl distribution keeps stable. In general, as the metamorphic degree goes higher, the content of oxygen-containing polar group tends to reduce. According to the measurement results, the contact angle is negatively related to the content of oxygen element, surface oxygen, and polar groups. In addition, compared with surface oxygen content, the content of oxygen-containing polar group serves as a more reasonable indicator of coal dust wettability.

  15. Limitations of potentiometric oxygen sensors operating at low oxygen levels

    DEFF Research Database (Denmark)

    Lund, Anders; Jacobsen, Torben; Hansen, Karin Vels

    2011-01-01

    The electrochemical processes that limit the range of oxygen partial pressures in which potentiometric oxygen sensors can be used, were analysed using a theoretical and an experimental approach. Electrochemical impedance spectroscopy was performed on porous Pt/yttria stabilised zirconia (YSZ......) electrodes between 10−6 and 0.2 bar and at temperatures between 500 and 950 °C. The flow of oxide ions and electron holes through a sensor cell, with a YSZ electrolyte, were calculated under similar conditions. The oxygen permeation of the sensor cell was insignificant at an oxygen partial pressure of 10...... sensors can be used....

  16. Oxygen Transport Ceramic Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay; N. Nagabhushana; X.-D Zhou; Q. Cai; J. Yang; W.B. Yelon; W.J. James; H.U. Anderson; Alan Jacobson; C.A. Mims

    2004-05-01

    The present quarterly report describes some of the investigations on the structural properties of dense OTM bars provided by Praxair and studies on newer composition of Ti doped LSF. In this report, in situ neutron diffraction was used to characterize the chemical and structural properties of La{sub 0.2}Sr{sub 0.8}Fe{sub 0.55}Ti{sub 0.45}O{sub 3-{delta}} (here after as L2SF55T) specimen, which was subject to measurements of neutron diffraction from room temperature to 900 C. It was found that space group of R3c yielded a better refinement than a cubic structure of Pm3m. Oxygen occupancy was nearly 3 in the region from room temperature to 700 C, above which the occupancy decreased due to oxygen loss. Dense OTM bars provided by Praxair were loaded to fracture at varying stress rates. Studies were done at room temperature in air and at 1000 C in a specified environment to evaluate slow crack growth behavior. The X-Ray data and fracture mechanisms points to non-equilibrium decomposition of the LSFCO OTM membrane. The non-equilibrium conditions could probably be due to the nature of the applied stress field (stressing rates) and leads to transition in crystal structures and increased kinetics of decomposition. The formations of a Brownmillerite or Sr2Fe2O5 type structures, which are orthorhombic are attributed to the ordering of oxygen vacancies. The cubic to orthorhombic transitions leads to 2.6% increase in strains and thus residual stresses generated could influence the fracture behavior of the OTM membrane. Continued investigations on the thermodynamic properties (stability and phase-separation behavior) and total conductivity of prototype membrane materials were carried out. The data are needed together with the kinetic information to develop a complete model for the membrane transport. Previously characterization, stoichiometry and conductivity measurements for samples of La{sub 0.2}Sr{sub 0.8}Fe{sub 0.55}Ti{sub 0.45}O{sub 3-{delta}} were reported. In this report

  17. Inhomogeneous depletion of oxygen ions in metal oxide nanoparticles

    Science.gov (United States)

    Vykhodets, Vladimir B.; Jarvis, Emily A. A.; Kurennykh, Tatiana E.; Beketov, Igor V.; Obukhov, Sviatoslav I.; Samatov, Oleg M.; Medvedev, Anatoly I.; Davletshin, Andrey E.; Whyte, Travis H.

    2016-02-01

    Zirconia and yttria stabilized zirconia (YSZ) have multiple uses, including catalysis, fuel cells, dental applications, and thermal coatings. We employ nuclear reaction analysis to determine elemental composition of YSZ nanoparticles synthesized by laser evaporation including 18O studies to distinguish between oxide and adsorbed oxygen content as a function of surface area. We see dramatic deviation from stoichiometry that can be traced to loss of oxygen from the oxide near the surface of these nanopowders. Density functional calculations are coupled with these experimental studies to explore the electronic structure of nonstoichiometric surfaces achieved through depletion of oxygen. Our results show oxygen-depleted surfaces present under oxygen potentials where stoichiometric, oxygen-terminated surfaces would be favored thermodynamically for crystalline systems. Oxygen depletion at nanopowder surfaces can create effective two-dimensional surface metallic states while maintaining stoichiometry in the underlying nanoparticle core. This insight into nanopowder surfaces applies to dissimilar oxides of aluminum and zirconium indicating synthesis conditions may be more influential than the inherent oxide properties and displaying need for distinct models for nanopowders of these important engineering materials where surface chemistry dominates performance.

  18. Obesity Decreases Perioperative Tissue Oxygenation

    Science.gov (United States)

    Kabon, Barbara; Nagele, Angelika; Reddy, Dayakar; Eagon, Chris; Fleshman, James W.; Sessler, Daniel I.; Kurz, Andrea

    2005-01-01

    Background: Obesity is an important risk factor for surgical site infections. The incidence of surgical wound infections is directly related to tissue perfusion and oxygenation. Fat tissue mass expands without a concomitant increase in blood flow per cell, which might result in a relative hypoperfusion with decreased tissue oxygenation. Consequently, we tested the hypotheses that perioperative tissue oxygen tension is reduced in obese surgical patients. Furthermore, we compared the effect of supplemental oxygen administration on tissue oxygenation in obese and non-obese patients. Methods: Forty-six patients undergoing major abdominal surgery were assigned to one of two groups according to their body mass index (BMI): BMI < 30 kg/m2 (non-obese) and BMI ≥ 30 kg/m2 (obese). Intraoperative oxygen administration was adjusted to arterial oxygen tensions of ≈150 mmHg and ≈300 mmHg in random order. Anesthesia technique and perioperative fluid management were standardized. Subcutaneous tissue oxygen tension was measured with a polarographic electrode positioned within a subcutaneous tonometer in the lateral upper arm during surgery, in the recovery room, and on the first postoperative day. Postoperative tissue oxygen was also measured adjacent to the wound. Data were compared with unpaired two tailed t-tests and Wilcoxon rank-sum tests; P < 0.05 was considered statistically significant. Results: Intraoperative subcutaneous tissue oxygen tension was significantly less in the obese patients at baseline (36 vs. 57 mmHg, P = 0.002) and with supplemental oxygen administration (47 vs. 76 mmHg, P = 0.014). Immediate postoperative tissue oxygen tension was also significantly less in subcutaneous tissue of the upper arm (43 vs. 54 mmHg, P = 0.011) as well as near the incision (42 vs. 62 mmHg, P = 0.012) in obese patients. In contrast, tissue oxygen tension was comparable in each group on the first postoperative morning. Conclusion: Wound and tissue hypoxia were common in obese

  19. Oxygen dynamics in the aftermath of the Great Oxidation of Earth’s atmosphere

    DEFF Research Database (Denmark)

    Canfield, Donald Eugene; Ngombi-Pemba, Lauriss; Hammarlund, Emma

    2013-01-01

    The oxygen content of Earth’s atmosphere has varied greatly through time, progressing from exceptionally low levels before about 2.3 billion years ago, to much higher levels afterward. In the absence of better information, we usually view the progress in Earth’s oxygenation as a series of steps f...

  20. Thermoacoustic in vivo determination of blood oxygenation

    Science.gov (United States)

    Kiser, William L., Jr.; Kruger, Robert A.; Reinecke, Daniel R.; Kruger, Gabe A.; Miller, Kathy D.

    2004-07-01

    We have utilized a prototype Thermoacoustic Computed Tomography Small Animal Imaging System to acquire images of athymic mice with bilateral tumors implanted in the cranial mammary fat pads. The breast tumor cell lines used in the study, which are MCF7, and MCF7 transfected with Vascular Endothelial Growth Factor (VEGF), exhibit distinctly contrasting levels of vascularization. Three dimensional images of the mice, acquired using pulses of NIR stimulating light, demonstrate the ability of the system to generate high resolution images of the vascular system up to one inch deep in tissue, and at the same time, differentiate tissue types based on the infrared absorption properties of the tissue; a property related in part to blood content and oxygenation levels. We have processed images acquired at different stimulating wavelengths to generate images representative of the distribution of oxygenated and deoxygenated hemoglobin throughout the tumors. The images demonstrate the in vivo capabilities of the imaging system and map system structure as well as the total, oxygenated and deoxygenated hemoglobin components of the blood.

  1. Optic nerve oxygenation

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Pedersen, Daniella Bach; Jensen, Peter Koch

    2005-01-01

    at similar levels of perfusion pressure. The levels of perfusion pressure that lead to optic nerve hypoxia in the laboratory correspond remarkably well to the levels that increase the risk of glaucomatous optic nerve atrophy in human glaucoma patients. The risk for progressive optic nerve atrophy in human...... glaucoma patients is six times higher at a perfusion pressure of 30 mmHg, which corresponds to a level where the optic nerve is hypoxic in experimental animals, as compared to perfusion pressure levels above 50 mmHg where the optic nerve is normoxic. Medical intervention can affect optic nerve oxygen......-oxygenase inhibitor, indomethacin, which indicates that prostaglandin metabolism plays a role. Laboratory studies suggest that carbonic anhydrase inhibitors might be useful for medical treatment of optic nerve and retinal ischemia, potentially in diseases such as glaucoma and diabetic retinopathy. However, clinical...

  2. A Small Oxygen Concentrator

    Science.gov (United States)

    1985-12-01

    150- S40- 20- 10 0 0 10 i0 30 40 NUIT PRESS=R (psig Figure 7. Percentage of oxygen. versus inlet pressure when using Soc with 131 molecular s ieve. 70...chick valve ano *move the plunger and spring. Disca the plunger; the spring will W• reused. Mill a SS sleeve to 0.535" 0.0. and 0.50" I.D. and press tit...the fjur 1" caps. The i n- side of two of the caps is milled flat to a diameteýr of 7/8". P-Kace one ena of a 10’, length of 1/2" SS tube in each Of

  3. Optic nerve oxygenation

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Pedersen, Daniella Bach; Jensen, Peter Koch;

    2005-01-01

    at similar levels of perfusion pressure. The levels of perfusion pressure that lead to optic nerve hypoxia in the laboratory correspond remarkably well to the levels that increase the risk of glaucomatous optic nerve atrophy in human glaucoma patients. The risk for progressive optic nerve atrophy in human...... glaucoma patients is six times higher at a perfusion pressure of 30 mmHg, which corresponds to a level where the optic nerve is hypoxic in experimental animals, as compared to perfusion pressure levels above 50 mmHg where the optic nerve is normoxic. Medical intervention can affect optic nerve oxygen......-oxygenase inhibitor, indomethacin, which indicates that prostaglandin metabolism plays a role. Laboratory studies suggest that carbonic anhydrase inhibitors might be useful for medical treatment of optic nerve and retinal ischemia, potentially in diseases such as glaucoma and diabetic retinopathy. However, clinical...

  4. Selectivity in the carbon-oxygen reaction

    Science.gov (United States)

    Skokova, Kristina A.

    The dependence of the carbon-oxygen reaction rate and the CO/COsb2 ratio on temperature, oxygen pressure, carbon crystallite size, concentration of surface C(O) complexes, and content of heteroatoms was studied. It was shown that the temperature dependence of the CO/COsb2 ratio obeys an Arrhenius-type relationship, but the pre-exponential factor and the activation energy depend on oxygen pressure and carbon nature. The Arrhenius parameters were found to be directly proportional to each other. This confirmed the importance of the compensation effect in carbon oxidation. It was explained by active site heterogeneity in carbon materials. For all experimental conditions, the CO/COsb2 ratio was lower for carbons with more ordered graphitic structure. It was shown that the CO/COsb2 ratio is inversely proportional to the surface coverage with reactive C(O) complexes. More ordered carbons were revealed to possess lower concentrations of stable complexes, higher surface coverages with reactive complexes and thus lower CO/COsb2 ratios. The influence of B and N heteroatoms on carbon reactivity and the CO/COsb2 ratio was studied. It was confirmed that B acts as an inhibitor of carbon oxidation due to the formation of a protective Bsb2Osb3 coating. The N presence in the carbon structure increases its rate of oxidation, maybe due to decreasing carbon crystallite dimensions. The CO/COsb2 ratio did not correlate with the N content in the carbon, but depended on the concentration of surface carbon-oxygen complexes. A new reaction mechanism is proposed. A key feature of the mechanism is that it takes into account the presence and mobility of oxygen atoms on the basal plane. It was shown with the aid of theoretical molecular orbital calculations that chemisorption on a pair of adjacent edge and basal sites is thermodynamically favorable as a parallel process to the generally accepted path of chemisorption on two edge carbon atoms. The former process can lead to the formation of a

  5. Saturn's Stratospheric Oxygen Compounds

    Science.gov (United States)

    Romani, Paul N.; Delgado Díaz, Héctor E.; Bjoraker, Gordon; Hesman, Brigette; Achterberg, Richard

    2016-10-01

    There are three known oxygenated species present in Saturn's upper atmosphere: H2O, CO and CO2. The ultimate source of the water must be external to Saturn as Saturn's cold tropopause effectively prevents any internal water from reaching the upper atmosphere. The carbon monoxide and dioxide source(s) could be internal, external, produced by the photochemical interaction of water with Saturn's stratospheric hydrocarbons or some combination of all of these. At this point it is not clear what the external source(s) are.Cassini's Composite InfraRed Spectrometer (CIRS) has detected emission lines of H2O and CO2 (Hesman et al., DPS 2015, 311.16 & Abbas et al. 2013, Ap. J. doi:10.1088/0004-637X/776/2/73) on Saturn. CIRS also retrieves the temperature of the stratosphere using CH4 lines at 7.7 microns. Using CIRS retrieved temperatures, the mole fraction of H2O at the 0.5-5 mbar level can be retrieved and the CO2 mole fraction at ~1-10 mbar. Coupled with ground based observations of CO (Cavalié et al., 2010, A&A, DOI: 10.1051/0004-6361/200912909) these observations provide a complete oxygen compound data set to test photochemical models.Preliminary results will be presented with an emphasis on upper limit analysis to determine the percentage of stratospheric CO and CO2 that can be produced photochemically from CIRS observational constraints on the H2O profile.

  6. S35: a new parameter in blood gas analysis for monitoring the systemic oxygenation.

    Science.gov (United States)

    Trouwborst, A; Tenbrinck, R; Van Woerkens, E C

    1990-01-01

    In the estimation of oxygen transport the term oxygen availability is used as the product of cardiac output and the arterial oxygen content (CaO2). Attempts can be made to modify the concept of oxygen availability by subtracting from the CaO2 the venous content at a critical PO2 as measured in mixed venous blood (Pv-O2), where oxygen diffusion into tissue becomes compromised and oxygen uptake (VO2) may decrease. The real arterial available oxygen content (CavlO2) can be calculated by estimating the saturation at the critical Pv-O2. For our concept S35 was chosen as such a dynamic baseline. Similar modification of oxygen extraction ratio (ERav) defined as VO2 divided by the real oxygen availability (O2av) should give, more than the classic ER, a realistic indices of oxygen availability in relation to oxygen consumption. It can be hypothesized that VO2 starts to decline when ERav is around 1.0. During isovolemic hemodilution VO2 started to drop when ERav reached 1.08 +/- 0.09. The S35 changed from 55.0 +/- 2.1% to 41.5 +/- 4.1%, correlated with changes in Pv-O2. A direct correlation was also found between the increase of the classic ER and the change in S35. We conclude that the S35, the CavlO2 and the ERav can be of value in monitoring the systemic oxygenation and that the concept also includes the effect of changes in oxyhemoglobin characteristics on oxygen delivery.

  7. Oxygen-reducing catalyst layer

    Energy Technology Data Exchange (ETDEWEB)

    O' Brien, Dennis P. (Maplewood, MN); Schmoeckel, Alison K. (Stillwater, MN); Vernstrom, George D. (Cottage Grove, MN); Atanasoski, Radoslav (Edina, MN); Wood, Thomas E. (Stillwater, MN); Yang, Ruizhi (Halifax, CA); Easton, E. Bradley (Halifax, CA); Dahn, Jeffrey R. (Hubley, CA); O' Neill, David G. (Lake Elmo, MN)

    2011-03-22

    An oxygen-reducing catalyst layer, and a method of making the oxygen-reducing catalyst layer, where the oxygen-reducing catalyst layer includes a catalytic material film disposed on a substrate with the use of physical vapor deposition and thermal treatment. The catalytic material film includes a transition metal that is substantially free of platinum. At least one of the physical vapor deposition and the thermal treatment is performed in a processing environment comprising a nitrogen-containing gas.

  8. Autoignition characteristics of oxygenated gasolines

    KAUST Repository

    Lee, Changyoul

    2017-08-14

    Gasoline anti-knock quality, defined by the research and motor octane numbers (RON and MON), is important for increasing spark ignition (SI) engine efficiency. Gasoline knock resistance can be increased using a number of blending components. For over two decades, ethanol has become a popular anti-knock blending agent with gasoline fuels due to its production from bio-derived resources. This work explores the oxidation behavior of two oxygenated certification gasoline fuels and the variation of fuel reactivity with molecular composition. Ignition delay times of Haltermann (RON = 91) and Coryton (RON = 97.5) gasolines have been measured in a high-pressure shock tube and in a rapid compression machine at three pressures of 10, 20 and 40 bar, at equivalence ratios of φ = 0.45, 0.9 and 1.8, and in the temperature range of 650–1250 K. The results indicate that the effects of fuel octane number and fuel composition on ignition characteristics are strongest in the intermediate temperature (negative temperature coefficient) region. To simulate the reactivity of these gasolines, three kinds of surrogates, consisting of three, four and eight components, are proposed and compared with the gasoline ignition delay times. It is shown that more complex surrogate mixtures are needed to emulate the reactivity of gasoline with higher octane sensitivity (S = RON–MON). Detailed kinetic analyses are performed to illustrate the dependence of gasoline ignition delay times on fuel composition and, in particular, on ethanol content.

  9. Dilute oxygen combustion. Phase I report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-01

    A novel burner, in which fuel (natural gas) and oxidant (oxygen or air) are separately injected into a furnace, shows promise for achieving very low nitrogen oxide(s) (NO{sub x}) emissions for commercial furnace applications. The dilute oxygen combustion (DOC) burner achieves very low NO{sub x} through in-furnace dilution of the oxidant stream prior to combustion, resulting in low flame temperatures, thus inhibiting thermal NO{sub x} production. The results of a fundamental and applied research effort on the development of the DOC burner are presented. In addition, the results of a market survey detailing the potential commercial impact of the DOC system are disclosed. The fundamental aspects of the burner development project involved examining the flame characteristics of a natural gas turbulent jet in a high-temperature ({approximately}1366 K) oxidant (7-27% O{sub 2} vol. wet). Specifically, the mass entrainment rate, the flame lift-off height, the velocity field and major species field of the jet were evaluated as a function of surrounding-gas temperature and composition. The measured entrainment rate of the fuel jet decreased with increasing oxygen content in the surrounding high-temperature oxidant, and was well represented by the d{sup +} scaling correlation found in the literature. The measured flame lift-off height decreased with increasing oxygen content and increasing temperature of the surrounding gas. An increase in surrounding-gas oxygen content and/or temperature inhibited the velocity decay within the jet periphery as a function of axial distance as compared to isothermal turbulent jets. However, the velocity measurements were only broadly represented by the d{sup +} scaling correlation. Several DOC burner configurations were tested in a laboratory-scale furnace at a nominal firing rate of 185 kW ({approximately}0.63 MMBtu/h). The flue gas composition was recorded as a function of furnace nitrogen content, furnace temperature, burner geometric

  10. Dilute Oxygen Combustion Phase I Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, H.M.; Riley, M.F.; Kobayashi, H.

    1997-10-31

    A novel burner, in which fuel (natural gas) and oxidant (oxygen or air) are separately injected into a furnace, shows promise for achieving very low nitrogen oxide(s) (NOx) emissions for commercial furnace applications. The dilute oxygen combustion (DOC) burner achieves very low NOx through in-furnace dilution of the oxidant stream prior to combustion, resulting in low flame temperatures, thus inhibiting thermal NOx production. The results of a fundamental and applied research effort on the development of the DOC burner are presented. In addition, the results of a market survey detailing the potential commercial impact of the DOC system are disclosed. The fundamental aspects of the burner development project involved examining the flame characteristics of a natural gas turbulent jet in a high-temperature (~1366 K) oxidant (7-27% O2 vol. wet). Specifically, the mass entrainment rate, the flame lift-off height, the velocity field and major species field of the jet were evaluated as a function of surrounding-gas temperature and composition. The measured entrainment rate of the fuel jet decreased with increasing oxygen content in the surrounding high-temperature oxidant, and was well represented by the d+ scaling correlation found in the literature. The measured flame lift-off height decreased with increasing oxygen content and increasing temperature of the surrounding gas. An increase in surrounding-gas oxygen content and/or temperature inhibited the velocity decay within the jet periphery as a function of axial distance as compared to isothermal turbulent jets. However, the velocity measurements were only broadly represented by the d+ scaling correlation. Several DOC burner configurations were tested in a laboratory-scale furnace at a nominal firing rate of 185 kW (~0.63 MMBtu/h). The flue gas composition was recorded as a function of furnace nitrogen content, furnace temperature, burner geometric arrangement, firing rate, and fuel injection velocity. NOx emissions

  11. Dilute Oxygen Combustion Phase 2 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, H.M.; Riley, M.F.; Kobayashi, H.

    2005-09-30

    A novel burner, in which fuel (natural gas) and oxidant (oxygen or air) are separately injected into a furnace, shows promise for achieving very low nitrogen oxide(s) (NOx) emissions for commercial furnace applications. The dilute oxygen combustion (DOC) burner achieves very low NOx through in-furnace dilution of the oxidant stream prior to combustion, resulting in low flame temperatures, thus inhibiting thermal NOx production. The results of a fundamental and applied research effort on the development of the DOC burner are presented. In addition, the results of a market survey detailing the potential commercial impact of the DOC system are disclosed. The fundamental aspects of the burner development project involved examining the flame characteristics of a natural gas turbulent jet in a high-temperature (~1366 K) oxidant (7-27% O2 vol. wet). Specifically, the mass entrainment rate, the flame lift-off height, the velocity field and major species field of the jet were evaluated as a function of surrounding-gas temperature and composition. The measured entrainment rate of the fuel jet decreased with increasing oxygen content in the surrounding high-temperature oxidant, and was well represented by the d+ scaling correlation found in the literature. The measured flame lift-off height decreased with increasing oxygen content and increasing temperature of the surrounding gas. An increase in surrounding-gas oxygen content and/or temperature inhibited the velocity decay within the jet periphery as a function of axial distance as compared to isothermal turbulent jets. However, the velocity measurements were only broadly represented by the d+ scaling correlation. Several DOC burner configurations were tested in a laboratory-scale furnace at a nominal firing rate of 185 kW (~0.63 MMBtu/h). The flue gas composition was recorded as a function of furnace nitrogen content, furnace temperature, burner geometric arrangement, firing rate, and fuel injection velocity. NOx emissions

  12. Analysis of intra-genomic GC content homogeneity within prokaryotes

    DEFF Research Database (Denmark)

    Bohlin, J; Snipen, L; Hardy, S.P.

    2010-01-01

    both aerobic and facultative microbes. Although an association has previously been found between mean genomic GC content and oxygen requirement, our analysis suggests that no such association exits when phylogenetic bias is accounted for. A significant association between GCVAR and mean GC content......Bacterial genomes possess varying GC content (total guanines (Gs) and cytosines (Cs) per total of the four bases within the genome) but within a given genome, GC content can vary locally along the chromosome, with some regions significantly more or less GC rich than on average. We have examined how...... the GC content varies within microbial genomes to assess whether this property can be associated with certain biological functions related to the organism's environment and phylogeny. We utilize a new quantity GCVAR, the intra-genomic GC content variability with respect to the average GC content...

  13. Integration of oxygen membranes for oxygen production in cement plants

    DEFF Research Database (Denmark)

    Puig Arnavat, Maria; Søgaard, Martin; Hjuler, Klaus;

    2015-01-01

    The present paper describes the integration of oxygen membranes in cement plants both from an energy, exergy and economic point of view. Different configurations for oxygen enrichment of the tertiary air for combustion in the pre-calciner and full oxy-fuel combustion in both pre-calciner and kiln...

  14. Streaming Virtual Reality Content

    OpenAIRE

    El-Ganainy, Tarek; Hefeeda, Mohamed

    2016-01-01

    The recent rise of interest in Virtual Reality (VR) came with the availability of commodity commercial VR prod- ucts, such as the Head Mounted Displays (HMD) created by Oculus and other vendors. To accelerate the user adoption of VR headsets, content providers should focus on producing high quality immersive content for these devices. Similarly, multimedia streaming service providers should enable the means to stream 360 VR content on their platforms. In this study, we try to cover different ...

  15. Content management systems (CMS)

    OpenAIRE

    Oriahi, Harrison

    2014-01-01

    This thesis describes the three most common and widely used content management systems (CMS) used to power several millions of business websites on the internet. Since there are many other content managements systems online, this report provides some helpful guides on each of the three most used systems and the web design projects that each of them maybe most suitable. There are plenty of options when it comes to selecting a content management system for a development project and this the...

  16. Scalable Content Management System

    Directory of Open Access Journals (Sweden)

    Sandeep Krishna S, Jayant Dani

    2013-10-01

    Full Text Available Immense growth in the volume of contents every day demands more scalable system to handle and overcome difficulties in capture, storage, transform, search, sharing and visualization of data, where the data can be a structured or unstructured data of any type. A system to manage the growing contents and overcome the issues and complexity faced using appropriate technologies would advantage over measurable qualities like flexibility, interoperability, customizability, security, auditability, quality, community support, options and cost of licensing. So architecting aContent Management System in terms of enterprise needs and a scalable solution to manage the huge data growth necessitates a Scalable Content Management System.

  17. Oxygen Transport Ceramic Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay; N. Nagabhushana; X.-D Zhou; Q. Cai; J. Yang; W.B. Yelon; W.J. James; H.U. Anderson; Alan Jacobson; C.A. Mims

    2004-10-01

    The present quarterly report describes some of the investigations on the structural properties of dense OTM bars provided by Praxair and studies on newer composition of Ti doped LSF. In this report, Moessbauer spectroscopy was used to study the local environmentals of LSFT with various level of oxygen deficiency. Ionic valence state, magnetic interaction and influence of Ti on superexchange are discussed Stable crack growth studies on Dense OTM bars provided by Praxair were done at elevated temperature, pressure and elevated conditions. Post-fracture X-ray data of the OTM fractured at 1000 C in environment were refined by FullProf code and results indicate a distortion of the parent cubic perovskite to orthorhombic structure with reduced symmetry. TGA-DTA studies on the post-fracture samples also indicated residual effect arising from the thermal and stress history of the samples. An electrochemical cell has been designed and built for measurements of the Seebeck coefficient as a function of temperature and pressure. The initial measurements on La{sub 0.2}Sr{sub 0.8}Fe{sub 0.55}Ti{sub 0.45}O{sub 3-{delta}} are reported. Neutron diffraction measurements of the same composition are in agreement with both the stoichiometry and the kinetic behavior observed in coulometric titration measurements. A series of isotope transients under air separation mode (small gradient) were completed on the membrane of LSCrF-2828 at 900 C. Low pO{sub 2} atmospheres based on with CO-CO{sub 2} mixtures have also been admitted to the delivery side of the LSCrF-2828 membrane to produce the gradients which exist under syngas generation conditions. The COCO{sub 2} mixtures have normal isotopic {sup 18}O abundances. The evolution of {sup 18}O on the delivery side in these experiments after an {sup 18}O pulse on the air side reveals a wealth of information about the oxygen transport processes.

  18. Tryptophan oxygenation: mechanistic considerations.

    Science.gov (United States)

    Naismith, James H

    2012-06-01

    From a protein structural viewpoint, tryptophan is often considered an inert structural amino acid, playing a role as a hydrophobic anchor in membrane proteins or as part of the hydrophobic core of soluble proteins. However, tryptophan is the only polyaromatic amino acid and, from a chemical viewpoint, possesses unique reactivity owing to the electron-richness of the indole system. This reactivity is seen in the area of natural products and metabolites which have exquisite modifications of the indole ring system. Enzymes have evolved multiple strategies to break or modify the indole ring; one particular class is the IDO/TDO (indoleamine/tryptophan dioxygenase) superfamily. A new member of this family, PrnB, on the surface catalyses a very different reaction, but actually shares much of the early chemistry with the tryptophan dioxygenases. Studies on PrnB have contributed to our understanding of the wider superfamily. In the present mini-review, recent developments in our understanding of how the TDO class of enzymes use activated molecular oxygen to break the indole ring are discussed.

  19. XPS study of surface absorbed oxygen of ABO3 mixed oxides

    Institute of Scientific and Technical Information of China (English)

    ZHAO Xin; YANG Qiuhua; CUI Jinjin

    2008-01-01

    Perovskite-type complex oxides ABO3 (A=Sr, La;B=Mn, Fe, Co) were prepared by citric acid method. The degradation of water-solubilized dyes was carried out using the mixed oxides as photocatalyst. The surface absorbed oxygen was analyzed using X-ray photoelectron spectroscopy (XPS). The results indicated that there was a relationship between the photocatalytic activity and the content of the surface absorbed oxygen. The higher the content of the surface absorbed oxygen was, the better the performance of the photocatalyst.

  20. Content-Based Instruction

    Science.gov (United States)

    DelliCarpini, M.; Alonso, O.

    2013-01-01

    DelliCarpini and Alonso's book "Content-Based Instruction" explores different approaches to teaching content-based instruction (CBI) in the English language classroom. They provide a comprehensive overview of how to teach CBI in an easy-to-follow guide that language teachers will find very practical for their own contexts. Topics…

  1. Branded content infantil

    Directory of Open Access Journals (Sweden)

    Raúl RODRÍGUEZ-FERRÁNDIZ

    2017-01-01

    Full Text Available Reseña del libro Bajo la influencia del branded content. Efectos de los contenidos de marca en niños y jóvenes. Review of the book Bajo la influencia del branded content. Efectos de los contenidos de marca en niños y jóvenes.

  2. Content Analysis: Television.

    Science.gov (United States)

    Williams, Tannis MacBeth; And Others

    Content analyses of the depiction of aggression and images of reality on Canadian television were performed on 109 program tapes of top-rated Toronto programs. Content was coded in terms of global messages communicated, character portrayals, context and setting of the program, amount and nature of conflict portrayed, and detailed information on…

  3. Print advertising : Vivid content

    NARCIS (Netherlands)

    Fennis, B.M.; Das, E.H.H.J.; Fransen, M.L.

    2012-01-01

    The present research examines the effects of vivid ad content in two types of appeal in print ads as a function of individual differences in chronically experienced vividness of visual imagery. For informational ads for a functional product, vivid ad content strongly affected individuals high in rep

  4. Print advertising: vivid content

    NARCIS (Netherlands)

    Fennis, B.M.; Das, E.; Fransen, M.L.

    2012-01-01

    The present research examines the effects of vivid ad content in two types of appeal in print ads as a function of individual differences in chronically experienced vividness of visual imagery. For informational ads for a functional product, vivid ad content strongly affected individuals high in rep

  5. Hydroponics: Content and Rationale

    Science.gov (United States)

    Ernst, Jeremy V.; Busby, Joe R.

    2009-01-01

    Technology education has the means of becoming the catalyst for integrated content and curricula, especially in core academic areas, such as science and mathematics, where it has been found difficult to incorporate other subject matter. Technology is diverse enough in nature that it can be addressed by a variety of content areas, serving as a true…

  6. Content-Based Instruction

    Science.gov (United States)

    DelliCarpini, M.; Alonso, O.

    2013-01-01

    DelliCarpini and Alonso's book "Content-Based Instruction" explores different approaches to teaching content-based instruction (CBI) in the English language classroom. They provide a comprehensive overview of how to teach CBI in an easy-to-follow guide that language teachers will find very practical for their own contexts. Topics…

  7. Hydroponics: Content and Rationale

    Science.gov (United States)

    Ernst, Jeremy V.; Busby, Joe R.

    2009-01-01

    Technology education has the means of becoming the catalyst for integrated content and curricula, especially in core academic areas, such as science and mathematics, where it has been found difficult to incorporate other subject matter. Technology is diverse enough in nature that it can be addressed by a variety of content areas, serving as a true…

  8. Oxygen detection using evanescent fields

    Science.gov (United States)

    Duan, Yixiang; Cao, Weenqing

    2007-08-28

    An apparatus and method for the detection of oxygen using optical fiber based evanescent light absorption. Methylene blue was immobilized using a sol-gel process on a portion of the exterior surface of an optical fiber for which the cladding has been removed, thereby forming an optical oxygen sensor. When light is directed through the optical fiber, transmitted light intensity varies as a result of changes in the absorption of evanescent light by the methylene blue in response to the oxygen concentration to which the sensor is exposed. The sensor was found to have a linear response to oxygen concentration on a semi-logarithmic scale within the oxygen concentration range between 0.6% and 20.9%, a response time and a recovery time of about 3 s, ant to exhibit good reversibility and repeatability. An increase in temperature from 21.degree. C. to 35.degree. C. does not affect the net absorption of the sensor.

  9. Social video content delivery

    CERN Document Server

    Wang, Zhi; Zhu, Wenwu

    2016-01-01

    This brief presents new architecture and strategies for distribution of social video content. A primary framework for socially-aware video delivery and a thorough overview of the possible approaches is provided. The book identifies the unique characteristics of socially-aware video access and social content propagation, revealing the design and integration of individual modules that are aimed at enhancing user experience in the social network context. The change in video content generation, propagation, and consumption for online social networks, has significantly challenged the traditional video delivery paradigm. Given the massive amount of user-generated content shared in online social networks, users are now engaged as active participants in the social ecosystem rather than as passive receivers of media content. This revolution is being driven further by the deep penetration of 3G/4G wireless networks and smart mobile devices that are seamlessly integrated with online social networking and media-sharing s...

  10. Effect of oxygen concentration on singlet oxygen luminescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Longchao; Lin, Lisheng; Li, Yirong; Lin, Huiyun; Qiu, Zhihai [MOE Key Laboratory of OptoElectronic Science and Technology for Medicine, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou 350007 (China); Gu, Ying [Department of Laser Medicine, Chinese PLA General Hospital, Beijing 100853 (China); Li, Buhong, E-mail: bhli@fjnu.edu.cn [MOE Key Laboratory of OptoElectronic Science and Technology for Medicine, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou 350007 (China)

    2014-08-01

    Singlet oxygen ({sup 1}O{sub 2}) is a major phototoxic component in photodynamic therapy (PDT) and its generation is dependent on the availability of tissue oxygen. To examine the effect of oxygen concentration on {sup 1}O{sub 2} detection, two hydrophilic photosensitizer (PS), rose bengal (RB) and meso-metra (N-methyl-4-pyridyl) porphine tetra tosylate (TMPyP) were used as model PS. Irradiation was carried out using 523 nm under hypoxic (2%, 13%), normoxic (21%) and hyperoxic (65%) conditions. The spectral and spatial resolved {sup 1}O{sub 2} luminescence was measured by near-infrared (NIR) photomultiplier tube (PMT) and camera, respectively. Upon the irradiation, the emission signal mainly consisted of background scattering light, PS fluorescence and phosphorescence, and {sup 1}O{sub 2} luminescence. The PS phosphorescence was evidently dependent on the oxygen concentration and PS type, which resulted in the change of emission profile of {sup 1}O{sub 2} luminescence. This change was further demonstrated on {sup 1}O{sub 2} luminescence image. The present study suggests that the low oxygen concentration could affect {sup 1}O{sub 2} luminescence detection. - Highlights: • Both spectral and spatial resolved {sup 1}O{sub 2} luminescence measurements were performed. • Effect of oxygen concentration on {sup 1}O{sub 2} generation was quantitatively evaluated. • Low oxygen concentration could affect {sup 1}O{sub 2} luminescence detection.

  11. Development of oxygen sensors for use in liquid metal

    Energy Technology Data Exchange (ETDEWEB)

    Van Nieuwenhove, Rudi [Institutt for Energiteknikk, Halden, (Norway); Ejenstam, Jesper; Szakalos, Peter [KTH Royal Institute of Technology, Division of Surface and Corrosion Science, Stockholm, (Sweden)

    2015-07-01

    For generation IV reactor concepts, based on liquid metal cooling, there is a need for robust oxygen sensors which can be used in the core of the reactor since corrosion can only be kept sufficiently low by controlling the dissolved oxygen content in the liquid metal. A robust, ceramic membrane type sensor has been developed at IFE/Halden (Norway) and tested in an autoclave system at KTH (Sweden). The sensor has been tested in lead-bismuth at 550 deg. C and performed well. (authors)

  12. Effect of Cd,Pb Stress on the Activated Oxygen Scavenging System in Tobacco Levves

    Institute of Scientific and Technical Information of China (English)

    严重玲; 洪业汤; 等

    1998-01-01

    The effect of Cd,Pb stress on the activated oxygen scavenging system indicates that the content of chlorophyll.chlorophyll a/b ratio and the activity of CAT gradually decrease,the activity of SOD increases first and then decreases,and the activity of POd Gradually in creases with incrasing concentrations of Cd and Pb,Between Cd and Pb there is synergism in the Activated oxygen scavenging system.The results show that the stress of Cd and Pb can affect the scavenging system of activated oxygen and result in imbalance of activated oxygen metabolism.

  13. Measurements of oxygen pressure in a copper flash smelting furnace by an EMF method

    Science.gov (United States)

    Kemori, Nobumasa; Shibata, Yukio; Tomono, Mutsuo

    1986-01-01

    Oxygen pressures in a copper flash smelting furnace were measured by means of the following galvanic cell: Fe, FeO/ZrO2 + MgO/ barO in slag or matte. Measured oxygen pressures were normalized to 1523 K with respect to the reaction: 4 FeO(l) + O2(g) = 4 FeO1.5(l). Vertical and horizontal variations of normalized oxygen pressures in the reaction shaft and in the settler were studied. The equilibrium relation between normalized oxygen pressure and the ratio of ferric to ferrous oxide content in the furnace slag was confirmed, and the activity coefficient ratio of these oxides was determined.

  14. Oxygen Transport Ceramic Membranes

    Energy Technology Data Exchange (ETDEWEB)

    S. Bandopadhyay; T. Nithyanantham; X.-D Zhou; Y-W. Sin; H.U. Anderson; Alan Jacobson; C.A. Mims

    2005-11-01

    The present quarterly report describes some of the investigations on the structural properties of dense OTM bars provided by Praxair and studies on newer composition of Ti doped LSF. In the current research, the electrical conductivity and Seebeck coefficient were measured as a function of temperature in air. Based on these measurements, the charge carrier concentration, net acceptor dopant concentration, activation energy of conduction and mobility were estimated. The studies on the fracture toughness of the LSFT and dual phase membranes at room temperature have been completed and reported previously. The membranes that are exposed to high temperatures at an inert and a reactive atmosphere undergo many structural and chemical changes which affects the mechanical properties. To study the effect of temperature on the membranes when exposed to an inert environment, the membranes (LAFT and Dual phase) were heat treated at 1000 C in air and N{sub 2} atmosphere and hardness and fracture toughness of the membranes were studied after the treatment. The indentation method was used to find the fracture toughness and the effect of the heat treatment on the mechanical properties of the membranes. Further results on the investigation of the origin of the slow kinetics on reduction of ferrites have been obtained. The slow kinetics appears to be related to a non-equilibrium reduction pathway that initially results in the formation of iron particles. At long times, equilibrium can be reestablished with recovery of the perovskite phase. 2-D modeling of oxygen movement has been undertaken in order to fit isotope data. The model will serve to study ''frozen'' profiles in patterned or composite membranes.

  15. Monitoring Cerebral Oxygenation in Neonates: An Update

    Science.gov (United States)

    Dix, Laura Marie Louise; van Bel, Frank; Lemmers, Petra Maria Anna

    2017-01-01

    Cerebral oxygenation is not always reflected by systemic arterial oxygenation. Therefore, regional cerebral oxygen saturation (rScO2) monitoring with near-infrared spectroscopy (NIRS) is of added value in neonatal intensive care. rScO2 represents oxygen supply to the brain, while cerebral fractional tissue oxygen extraction, which is the ratio between rScO2 and systemic arterial oxygen saturation, reflects cerebral oxygen utilization. The balance between oxygen supply and utilization provides insight in neonatal cerebral (patho-)physiology. This review highlights the potential and limitations of cerebral oxygenation monitoring with NIRS in the neonatal intensive care unit. PMID:28352624

  16. Oxygenates vs. synthesis gas

    Energy Technology Data Exchange (ETDEWEB)

    Kamil Klier; Richard G. Herman; Alessandra Beretta; Maria A. Burcham; Qun Sun; Yeping Cai; Biswanath Roy

    1999-04-01

    Methanol synthesis from H{sub 2}/CO has been carried out at 7.6 MPa over zirconia-supported copper catalysts. Catalysts with nominal compositions of 10/90 mol% and 30/70 mol% Cu/ZrO{sub 2} were used in this study. Additionally, a 3 mol% cesium-doped 10/90 catalyst was prepared to study the effect of doping with heavy alkali, and this promoter greatly increased the methanol productivity. The effects of CO{sub 2} addition, water injection, reaction temperature, and H{sub 2}/C0 ratio have been investigated. Both CO{sub 2} addition to the synthesis gas and cesium doping of the catalyst promoted methanol synthesis, while inhibiting the synthesis of dimethyl ether. Injection of water, however, was found to slightly suppress methanol and dimethyl ether formation while being converted to CO{sub 2} via the water gas shift reaction over these catalysts. There was no clear correlation between copper surface area and catalyst activity. Surface analysis of the tested samples revealed that copper tended to migrate and enrich the catalyst surface. The concept of employing a double-bed reactor with a pronounced temperature gradient to enhance higher alcohol synthesis was explored, and it was found that utilization of a Cs-promoted Cu/ZnO/Cr{sub 2}O{sub 3} catalyst as a first lower temperature bed and a Cs-promoted ZnO/Cr{sub 2}O{sub 3} catalyst as a second high-temperature bed significantly promoted the productivity of 2-methyl-1-propanol (isobutanol) from H{sub 2}/CO synthesis gas mixtures. While the conversion of CO to C{sub 2+} oxygenates over the double-bed configuration was comparable to that observed over the single Cu-based catalyst, major changes in the product distribution occurred by the coupling to the zinc chromite catalyst; that is, the productivity of the C{sub 1}-C{sub 3} alcohols decreased dramatically, and 2-methyl branched alcohols were selectively formed. The desirable methanol/2-methyl oxygenate molar ratios close to 1 were obtained in the present double

  17. Qualitative Content Analysis

    Directory of Open Access Journals (Sweden)

    Philipp Mayring

    2000-06-01

    Full Text Available The article describes an approach of systematic, rule guided qualitative text analysis, which tries to preserve some methodological strengths of quantitative content analysis and widen them to a concept of qualitative procedure. First the development of content analysis is delineated and the basic principles are explained (units of analysis, step models, working with categories, validity and reliability. Then the central procedures of qualitative content analysis, inductive development of categories and deductive application of categories, are worked out. The possibilities of computer programs in supporting those qualitative steps of analysis are shown and the possibilities and limits of the approach are discussed. URN: urn:nbn:de:0114-fqs0002204

  18. Encryption for digital content

    CERN Document Server

    Kiayias, Aggelos

    2010-01-01

    Encryption for Digital Content is an area in cryptography that is widely used in commercial productions (e.g., Blu-Ray and HD-DVDs). This book provides a comprehensive mathematical treatment of combinatorial encryption techniques used in digital content distribution systems and related attack models. A complete description of broadcast encryption with various revocation and tracing functionalities is included. ""Encryption for Digital Content"" introduces the subset cover framework (currently used in AACS, Blu-Ray and HD-DVDs,) and tracking/revocation mechanisms in various attack models. Pirat

  19. Oxygen absorption by skin exposed to oxygen supersaturated water

    National Research Council Canada - National Science Library

    Reading, Stacey A; Yeomans, Maggie

    2012-01-01

    ... min in 50 different experiments. Transcutaneous oximetry and near infrared spectroscopy were used to evaluate changes in skin PO 2 , oxygenated haemoglobin, and cytochrome oxidase aa 3 that resulted from treatment...

  20. CARINA oxygen data in the Atlantic Ocean

    Directory of Open Access Journals (Sweden)

    I. Stendardo

    2009-12-01

    Full Text Available In the CARINA (Carbon dioxide in the Atlantic Ocean project, a new dataset with many previously unpublished hydrographic data from the Atlantic, Arctic and Southern Ocean was assembled and subjected to careful quality control (QC procedures. Here, we present the dissolved oxygen measurements in the Atlantic region of the dataset and describe in detail the secondary QC procedures that aim to ensure that the data are internally consistent. This is achieved by a cross-over analysis, i.e. the comparison of deep ocean data at places that were sampled by different cruises at different times. Initial adjustments to the individual cruises were then determined by an inverse procedure that computes a set of adjustments that requires the minimum amount of adjustment and at the same time reduces the offsets in an optimal manner. The initial adjustments were then reviewed by the CARINA members, and only those that passed the following two criteria were adopted: (i the region is not subject to substantial temporal variability, and (ii the adjustment must be based on at least three stations from each cruise. No adjustment was recommended for cruises that did not fit these criteria. The final CARINA-Oxygen dataset has 103414 oxygen samples from 9491 stations obtained during 98 cruises covering three decades. The sampling density of the oxygen data is particularly good in the North Atlantic north of about 40° N especially after 1987. In contrast, the sample density in the South Atlantic is much lower. Some cruises appear to have poor data quality, and were subsequently omitted from the adjusted dataset. Of the data included in the adjusted dataset, 20% were adjusted with a mean adjustment of 2%. Due to the achieved internal consistency, the resulting product is well suited to produce an improved climatology or to study long-term changes in the oxygen content of the ocean. However, the adjusted dataset is not necessarily better suited than the unadjusted data to

  1. Advanced Oxygen Systems for Aircraft (Systemes d’Oxygene Avances)

    Science.gov (United States)

    1996-04-01

    son acheminement vers le convertisseur embarque, ainsi que la plus grande fiabilite de 1’OBOGS compare aux systemes ä oxygene liquide traditionnels...Standardisation Coordination Committee. Minimum Physiological Requirements for Aircrew Demand Breathing Systems. Air Standard 61/101/6A, Washington DC ...Washington DC 1981. 5. Ernsting J, and Stewart WK, Introduction to Oxygen Deprivation at Reduced Barometric Pressure in: Gilles JA, Ed., A Textbook of

  2. Oxygen potentials of transuranium oxides

    Energy Technology Data Exchange (ETDEWEB)

    Haruyoshi Otobe; Mituso Akabori; Arai Yasuo; Kazuo Minato [Nuclear Science and Engineering Directorate, Japan Atomic Energy Agency: Tokai-mura, Ibaraki-ken, 319-1195 (Japan)

    2008-07-01

    The oxygen potentials of pyrochlore-type Pu{sub 2}Zr{sub 2}O{sub 7+y}, fluorite-type (Pu{sub 0.5}Zr{sub 0.5})O{sub 2-x} and AmO{sub 2-x} have been measured by the electromotive force (EMF) method with a zirconia solid-electrolyte. The oxygen potentials of these oxides were reviewed. The phase relations, microstructure, equilibrium state of these oxides were discussed, referring to the isothermal curve of the oxygen potentials. (authors)

  3. total contents of phenolics, flavonoids, tannins and antioxidant ...

    African Journals Online (AJOL)

    and korefe (a malt beverage like beer) are made from a mixture of enkuro (a dark brown toasted ... reactions [10, 11], which are important sources of active oxygen radicals. .... Spectrophotometric measurements were performed on a UV-Vis spectrophotometer ( .... Both spirits and areke have low content of total phenolics.

  4. Oceanic oxygenation events in the anoxic Ediacaran ocean.

    Science.gov (United States)

    Sahoo, S K; Planavsky, N J; Jiang, G; Kendall, B; Owens, J D; Wang, X; Shi, X; Anbar, A D; Lyons, T W

    2016-09-01

    The ocean-atmosphere system is typically envisioned to have gone through a unidirectional oxygenation with significant oxygen increases in the earliest (ca. 635 Ma), middle (ca. 580 Ma), or late (ca. 560 Ma) Ediacaran Period. However, temporally discontinuous geochemical data and the patchy metazoan fossil record have been inadequate to chart the details of Ediacaran ocean oxygenation, raising fundamental debates about the timing of ocean oxygenation, its purported unidirectional rise, and its causal relationship, if any, with the evolution of early animal life. To better understand the Ediacaran ocean redox evolution, we have conducted a multi-proxy paleoredox study of a relatively continuous, deep-water section in South China that was paleogeographically connected with the open ocean. Iron speciation and pyrite morphology indicate locally euxinic (anoxic and sulfidic) environments throughout the Ediacaran in this section. In the same rocks, redox sensitive element enrichments and sulfur isotope data provide evidence for multiple oceanic oxygenation events (OOEs) in a predominantly anoxic global Ediacaran-early Cambrian ocean. This dynamic redox landscape contrasts with a recent view of a redox-static Ediacaran ocean without significant change in oxygen content. The duration of the Ediacaran OOEs may be comparable to those of the oceanic anoxic events (OAEs) in otherwise well-oxygenated Phanerozoic oceans. Anoxic events caused mass extinctions followed by fast recovery in biologically diversified Phanerozoic oceans. In contrast, oxygenation events in otherwise ecologically monotonous anoxic Ediacaran-early Cambrian oceans may have stimulated biotic innovations followed by prolonged evolutionary stasis.

  5. Learning Content Management Systems

    Directory of Open Access Journals (Sweden)

    Tache JURUBESCU

    2008-01-01

    Full Text Available The paper explains the evolution of e-Learning and related concepts and tools and its connection with other concepts such as Knowledge Management, Human Resources Management, Enterprise Resource Planning, and Information Technology. The paper also distinguished Learning Content Management Systems from Learning Management Systems and Content Management Systems used for general web-based content. The newest Learning Content Management System, very expensive and yet very little implemented is one of the best tools that helps us to cope with the realities of the 21st Century in what learning concerns. The debates over how beneficial one or another system is for an organization, can be driven by costs involved, efficiency envisaged, and availability of the product on the market.

  6. Fannish form and content

    Directory of Open Access Journals (Sweden)

    TWC Editor

    2014-09-01

    Full Text Available This issue showcases a variety of investigations into a myriad of platforms, featuring several essays that switch the focus from content to form and illustrate the importance of a range of different fan engagements.

  7. Scalable Content Management System

    OpenAIRE

    Sandeep Krishna S, Jayant Dani

    2013-01-01

    Immense growth in the volume of contents every day demands more scalable system to handle and overcome difficulties in capture, storage, transform, search, sharing and visualization of data, where the data can be a structured or unstructured data of any type. A system to manage the growing contents and overcome the issues and complexity faced using appropriate technologies would advantage over measurable qualities like flexibility, interoperability, customizabi...

  8. The Measurement of Dissolved Oxygen

    Science.gov (United States)

    Thistlethwayte, D.; And Others

    1974-01-01

    Describes an experiment in environmental chemistry which serves to determine the dissolved oxygen concentration in both fresh and saline water. Applications of the method at the undergraduate and secondary school levels are recommended. (CC)

  9. Oxygen-Methane Thruster Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two main innovations will be developed in the Phase II effort that are fundamentally associated with our gaseous oxygen/gaseous methane RCS thruster. The first...

  10. FORMATION OF VANILLIN AND SYRINGALDEHYDE IN AN OXYGEN DELIGNIFICATION PROCESS

    Directory of Open Access Journals (Sweden)

    Zhaojiang Wong

    2010-05-01

    Full Text Available The formation of vanillin and syringaldehyde during an oxygen delignification process was evaluated. The cleavage of conjugated Cα-Cβ bonds in phenolic lignin caused by the attack of oxygen leads to the formation of aromatic aldehydes and ketones. The formation mechanism was confirmed by the organic compounds identified in the spent liquor by GC/MS. Additionally, the formation of aromatic aldehydes and ketones of hardwood, softwood, and grass was investigated. The results showed that the formed aromatic aldehydes and ketones were related to the units of lignin structure. Among the aromatic aldehydes and ketones present in the spent liquor from oxygen delignification, vanillin and syringaldehyde are of high content, making the spent liquor a potential resource for vanillin and syringaldehyde production.

  11. Sintering of transparent Nd:YAG ceramics in oxygen atmosphere

    Institute of Scientific and Technical Information of China (English)

    HUANG Yihua; JIANG Dongliang; ZHANG Jingxian; LIN Qingling; HUANG Zhengren

    2013-01-01

    Yttrium aluminum garnet (YAG) transparent ceramics were fabricated by sintering at oxygen atmosphere.Tetraethyl orthosilicate (TEOS) was added as the sintering additive to control the grain growth and densification.Pores were eliminated clearly at temperature lower than 1700 ℃,while grain size was around 3 μm.The in-line transmittance was 80% at 1064 nm when samples vere sintered at 1710 ℃.The effect of TEOS was studied in oxygen atmosphere sintering for Nd:YAG transparent ceramics.At higher temperature like 1710 ℃,the grain growth mechanism was solute drag,while at 1630 and 1550 ℃ the grain growth was controlled by liquid phase sintering mechanism.And 0.5 wt.% TEOS was the best adding content for Nd:YAG sintered in oxygen atmosphere.

  12. Statistical treatment of oxygenation-related data in muscle tissue.

    Science.gov (United States)

    Hoofd, Louis; Degens, Hans

    2013-01-01

    Muscle oxygenation is determined not only by the flow and oxygen content of the supplying blood but also by the density of the capillary network, the heterogeneity of the distribution of the capillaries and the properties and distribution of the muscle fibres. The distribution of the capillaries is adequately analysed by the method of capillary domains, which also allows to link capillaries to individual fibres. Thus, capillarisation can be linked to cell properties like fibre cross-sectional surface area and perimeter, and oxygen consumption of the individual muscle fibres. However, in order to meaningfully characterise tissue properties, such linkage has to be done for groups of cells. Since most of the data are not normally distributed - domains are lognormally distributed, but how fibre cross-sectional areas are distributed is unknown - a dedicated statistical analysis is required, particularly since none of the variables is independent.

  13. Thermal analyses of the lignite combustion in oxygen-enriched atmosphere

    Directory of Open Access Journals (Sweden)

    Chen Xiangyun

    2015-01-01

    Full Text Available In this work, the oxygen-enriched combustion behavior of indigenous lignite was measured by a thermogravimetric analyzer (TG. Combustion tests were carried out in N2/O2 atmosphere with an oxygen content ranging from 21% to 70 vol%.The data show that the calorific value per unit time (CVT of the lignite was improved with increased oxygen concentration. In order to reveal the oxygen-enriched combustion process in detail, a new index of characteristic temperature Tc was defined to indicate the fixed carbon behavior during burning, and the combustibility indexes D’, Rw, and S were calculated to determine the combustion performance. The functional relation between CVT and oxygen concentration was determined by non-linear fitting method. The results indicated that the relationship between CVT and oxygen concentration fit the exponential function exactly.

  14. Iron plaques improve the oxygen supply to root meristems of the freshwater plant, Lobelia dortmanna

    DEFF Research Database (Denmark)

    Møller, Claus Lindskov; Sand-Jensen, Kaj

    2008-01-01

    * High radial oxygen loss (ROL) from roots of aquatic plants to reduced sediments is thought to deplete the roots of oxygen and restrict the distribution of those species unable to form a barrier to oxygen loss. Metal precipitates with high iron content (Fe-plaques) frequently form on roots...... of aquatic plants and could create such a diffusion barrier, thereby diverting a larger proportion of downward oxygen transport to the root meristems. * To investigate whether Fe-plaques form a barrier to oxygen loss, ROL and internal oxygen concentrations were measured along the length of roots...... of the freshwater plant Lobelia dortmanna using platinum sleeve electrodes and Clark-type microelectrodes. * Measurements showed that ROL was indeed lower from roots with Fe-plaques than roots without plaques and that ROL declined gradually with thicker iron coating on roots. The low ROL was caused by low diffusion...

  15. Wet steam treatment with oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Ruehle, W.; Enkler, G. [EnBW Kraftwerke AG, Kernkraftwerk Philippsburg (Germany)

    1999-07-01

    After many years of excellent results using high all volatile treatment (HAVT) for operation of the secondary system of a PWR, flow assisted corrosion in the heating pipes of the intermediate steam reheaters has been experienced. Oxygen addition into the heating steam before the reheater is expected to improve the protective oxide layers formation. The reaction of oxygen with the alkalizing steam ingredients is described. (orig.)

  16. The Wulf bands of oxygen

    Science.gov (United States)

    Bernath, Peter; Carleer, Michel; Fally, Sophie; Jenouvrier, Alain; Vandaele, Ann Carine; Hermans, Christian; Mérienne, Marie-France; Colin, Reginald

    1998-11-01

    The Wulf bands of oxygen in the 240-290 nm spectral region are caused by collision-induced absorption of the Herzberg III ( A' 3Δu- X3Σ-g) system. These bands had been previously attributed to the oxygen dimer, (O 2) 2. Under atmospheric conditions the Wulf bands are thus the long-wavelength extension of the Herzberg continuum. Absorption of solar radiation by the Wulf bands may be an additional source of NO in the stratosphere.

  17. Ebullitive methane emissions from oxygenated wetland streams.

    Science.gov (United States)

    Crawford, John T; Stanley, Emily H; Spawn, Seth A; Finlay, Jacques C; Loken, Luke C; Striegl, Robert G

    2014-11-01

    Stream and river carbon dioxide emissions are an important component of the global carbon cycle. Methane emissions from streams could also contribute to regional or global greenhouse gas cycling, but there are relatively few data regarding stream and river methane emissions. Furthermore, the available data do not typically include the ebullitive (bubble-mediated) pathway, instead focusing on emission of dissolved methane by diffusion or convection. Here, we show the importance of ebullitive methane emissions from small streams in the regional greenhouse gas balance of a lake and wetland-dominated landscape in temperate North America and identify the origin of the methane emitted from these well-oxygenated streams. Stream methane flux densities from this landscape tended to exceed those of nearby wetland diffusive fluxes as well as average global wetland ebullitive fluxes. Total stream ebullitive methane flux at the regional scale (103 Mg C yr(-1) ; over 6400 km(2) ) was of the same magnitude as diffusive methane flux previously documented at the same scale. Organic-rich stream sediments had the highest rates of bubble release and higher enrichment of methane in bubbles, but glacial sand sediments also exhibited high bubble emissions relative to other studied environments. Our results from a database of groundwater chemistry support the hypothesis that methane in bubbles is produced in anoxic near-stream sediment porewaters, and not in deeper, oxygenated groundwaters. Methane interacts with other key elemental cycles such as nitrogen, oxygen, and sulfur, which has implications for ecosystem changes such as drought and increased nutrient loading. Our results support the contention that streams, particularly those draining wetland landscapes of the northern hemisphere, are an important component of the global methane cycle.

  18. Ebullitive methane emissions from oxygenated wetland streams

    Science.gov (United States)

    Crawford, John T.; Stanley, Emily H.; Spawn, Seth A.; Finlay, Jacques C.; Striegl, Robert G.

    2014-01-01

    Stream and river carbon dioxide emissions are an important component of the global carbon cycle. Methane emissions from streams could also contribute to regional or global greenhouse gas cycling, but there are relatively few data regarding stream and river methane emissions. Furthermore, the available data do not typically include the ebullitive (bubble-mediated) pathway, instead focusing on emission of dissolved methane by diffusion or convection. Here, we show the importance of ebullitive methane emissions from small streams in the regional greenhouse gas balance of a lake and wetland-dominated landscape in temperate North America and identify the origin of the methane emitted from these well-oxygenated streams. Stream methane flux densities from this landscape tended to exceed those of nearby wetland diffusive fluxes as well as average global wetland ebullitive fluxes. Total stream ebullitive methane flux at the regional scale (103 Mg C yr−1; over 6400 km2) was of the same magnitude as diffusive methane flux previously documented at the same scale. Organic-rich stream sediments had the highest rates of bubble release and higher enrichment of methane in bubbles, but glacial sand sediments also exhibited high bubble emissions relative to other studied environments. Our results from a database of groundwater chemistry support the hypothesis that methane in bubbles is produced in anoxic near-stream sediment porewaters, and not in deeper, oxygenated groundwaters. Methane interacts with other key elemental cycles such as nitrogen, oxygen, and sulfur, which has implications for ecosystem changes such as drought and increased nutrient loading. Our results support the contention that streams, particularly those draining wetland landscapes of the northern hemisphere, are an important component of the global methane cycle.

  19. Oxygen-deficient metabolism and corneal edema.

    Science.gov (United States)

    Leung, B K; Bonanno, J A; Radke, C J

    2011-11-01

    Wear of low-oxygen-transmissible soft contact lenses swells the cornea significantly, even during open eye. Although oxygen-deficient corneal edema is well-documented, a self-consistent quantitative prediction based on the underlying metabolic reactions is not available. We present a biochemical description of the human cornea that quantifies hypoxic swelling through the coupled transport of water, salt, and respiratory metabolites. Aerobic and anaerobic consumption of glucose, as well as acidosis and pH buffering, are incorporated in a seven-layer corneal model (anterior chamber, endothelium, stroma, epithelium, postlens tear film, contact lens, and prelens tear film). Corneal swelling is predicted from coupled transport of water, dissolved salts, and especially metabolites, along with membrane-transport resistances at the endothelium and epithelium. At the endothelium, the Na+/K+ - ATPase electrogenic channel actively transports bicarbonate ion from the stroma into the anterior chamber. As captured by the Kedem-Katchalsky membrane-transport formalism, the active bicarbonate-ion flux provides the driving force for corneal fluid pump-out needed to match the leak-in tendency of the stroma. Increased lactate-ion production during hypoxia osmotically lowers the pump-out rate requiring the stroma to swell to higher water content. Concentration profiles are predicted for glucose, water, oxygen, carbon dioxide, and hydronium, lactate, bicarbonate, sodium, and chloride ions, along with electrostatic potential and pressure profiles. Although the active bicarbonate-ion pump at the endothelium drives bicarbonate into the aqueous humor, we find a net flux of bicarbonate ion into the cornea that safeguards against acidosis. For the first time, we predict corneal swelling upon soft-contact-lens wear from fundamental biophysico-chemical principles. We also successfully predict that hypertonic tear alleviates contact-lens-induced edema.

  20. A theory of atmospheric oxygen.

    Science.gov (United States)

    Laakso, T A; Schrag, D P

    2017-05-01

    Geological records of atmospheric oxygen suggest that pO2 was less than 0.001% of present atmospheric levels (PAL) during the Archean, increasing abruptly to a Proterozoic value between 0.1% and 10% PAL, and rising quickly to modern levels in the Phanerozoic. Using a simple model of the biogeochemical cycles of carbon, oxygen, sulfur, hydrogen, iron, and phosphorous, we demonstrate that there are three stable states for atmospheric oxygen, roughly corresponding to levels observed in the geological record. These stable states arise from a series of specific positive and negative feedbacks, requiring a large geochemical perturbation to the redox state to transition from one to another. In particular, we show that a very low oxygen level in the Archean (i.e., 10(-7) PAL) is consistent with the presence of oxygenic photosynthesis and a robust organic carbon cycle. We show that the Snowball Earth glaciations, which immediately precede both transitions, provide an appropriate transient increase in atmospheric oxygen to drive the atmosphere either from its Archean state to its Proterozoic state, or from its Proterozoic state to its Phanerozoic state. This hypothesis provides a mechanistic explanation for the apparent synchronicity of the Proterozoic Snowball Earth events with both the Great Oxidation Event, and the Neoproterozoic oxidation. © 2017 John Wiley & Sons Ltd.

  1. Temperature and oxygen visual estimator for carbonization process control

    Science.gov (United States)

    Martínez, Fredy; Martínez, Fernando; Montiel, Holman

    2017-02-01

    This paper proposes a visual estimator for temperature and oxygen content for closed loop control of carbonization furnace in the production of activated carbon. The carbonization process involves thermal decomposition of vegetal material in the absence of air; this requires rigorous sensing and control of these two variables. The system consists of two cameras, a thermographic camera to estimate the temperature, and a traditional digital camera to estimate the oxygen content. In both cases we use similarity measures between images to estimate the value of the variables into the furnace, estimation that is used to control the furnace flame. The algorithm is tested with reference photos taken at the production plant, and the experimental results prove the performance of the proposed technique.

  2. Diagnosis of Compartment Syndrome Based on Tissue Oxygenation

    Science.gov (United States)

    2014-10-24

    c. THIS PAGE U UU 11 19b. TELEPHONE NUMBER (include area code) Table of Contents...measurement of intramuscular tissue oxygenation (PmO2) of the leg during controlled induction of CS in a canine model and the development of warning...inotropic and vasoactive drugs to enhance tissue perfusion. BODY Previously reported findings: In the previous report, we reported that in Phase

  3. Apollo 11 ilmenite revisited. [lunar resources of oxygen and water

    Science.gov (United States)

    Cameron, E. N.

    1992-01-01

    An account is given of the problems associated with beneficiation of the high-Ti regolith represented by Apollo 11's ilmenite sample. Magnetic and electrostatic separation, combined with sizing to reject all but the best fractions of the lunar regolith, will be essential; the production of high-grade ilmenite concentrates on the scale required for lunar oxygen production may still, however, be unachievable. These findings suggest that ilmenite production directly from high-Ti-content basalt may be a superior alternative.

  4. Muscle metabolism from near infrared spectroscopy during rhythmic handgrip in humans

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Pott, F; Madsen, P

    1998-01-01

    The rate of metabolism in forearm flexor muscles (MO2) was derived from near-infrared spectroscopy (NIRS-O2) during ischaemia at rest rhythmic handgrip at 15% and 30% of maximal voluntary contraction (MVC), post-exercise muscle ischaemia (PEMI), and recovery in seven subjects. The MO2 was compare....... To conclude, NIRS-O2 of forearm flexor muscles closely reflected the exercise intensity and the metabolic rate determined by magnetic resonance spectroscopy but not that rate derived from flow and the arterio-venous oxygen difference.......The rate of metabolism in forearm flexor muscles (MO2) was derived from near-infrared spectroscopy (NIRS-O2) during ischaemia at rest rhythmic handgrip at 15% and 30% of maximal voluntary contraction (MVC), post-exercise muscle ischaemia (PEMI), and recovery in seven subjects. The MO2 was compared...... with forearm oxygen uptake (VO2) [flow x (oxygen saturation in arnterial blood-oxygen saturation in venous blood, SaO2 - SvO2)], and with the 31P-magnetic resonance spectroscopy-determined ratio of inorganic phosphate to phosphocreatine (P(I):PCr). During ischaemia at rest, the fall in NIRS-O2 was more...

  5. The difference of the PDT's effects between interstitial lighting and continuous lighting in low oxygen density

    Science.gov (United States)

    Yang, Jiumin; Li, Yingxin; Liu, Tiegen; Xu, Tao

    2008-02-01

    Tumor oxygen depletion plays an important role in the process of Photodynamic Therapy (PDT). The paper focuses on the improvement of the lighting mode to carry out this cancer therapy more effectively in low oxygen content. The effect of interstitial lighting was compared with that of continuous lighting in different oxygen density measured with a homemade device in PDT. 90 mice were divided into 3 groups: the contrast group, the continuous lighting group and the interstitial lighting group. The initial oxygen content was measured with a homemade device before the treatment. To examine the different effects, both the interstitial lighting and the continuous lighting have the same fluent rates (30mW/cm2, 32.4J/ cm2). The continuous lighting lasted 18 minutes while the interstitial lighting lasted 36 minutes with 1 second's idle time and 1 second's effective time of each pulse. The result shows that the volume of tumor doubling duration in interstitial lighting group is longer in the condition of low initial oxygen content. Thus with low initial oxygen content, the interstitial lighting is more effective than the continuous lighting during PDT.

  6. Removal of trichlorobenzene using 'oxygen-enriched' highly active absorbent.

    Science.gov (United States)

    Zhao, Yi; He, Peng; Zhang, Yu-Hai; Ma, Shuangchen

    2011-01-01

    Fly ash, industry lime and an additive, Ca(ClO2)2 (C) were used to prepare the 'oxygen-enriched' highly active absorbent (HAA). The influencing factors for removal of 1,2,4-trichlorobenzene (TCB) using this absorbent such as reaction temperature, simulating gas flow rate, oxygen content, etc. were studied in a self-designed reactor. The optimum experimental conditions of removing 1,2,4-TCB are that the content of an oxidizing additive in the absorbent is 3% (wt), simulating gas flow rate is 100 mL/min, reaction temperature is 250 degrees C, and the content of oxygen in simulating gas is 6%. The maximum removal efficiency is 81.71% in 10 mins. The absorption capacity of the absorbent is 0.000111 g/g. The reaction products were determined by gas chromatograph/mass spectrometer (GC/ MS), 2,6-Bis-[1,1-Dimethylethyl]-4-methyl-Phenol is considered to be the major intermediate product. The reaction route was revealed.

  7. Enhanced gas sensing performance of Li-doped ZnO nanoparticle film by the synergistic effect of oxygen interstitials and oxygen vacancies

    Science.gov (United States)

    Zhao, Jianwei; Xie, Changsheng; Yang, Li; Zhang, Shunping; Zhang, Guozhu; Cai, Ziming

    2015-03-01

    Li doped ZnO (Zn1-xLixO) nanoparticles with different content were synthesized. X-ray photoelectron spectroscopy (XPS) indicated that the ratio of oxygen to zinc for ZnO increased with increasing of Li content from x = 0 to 0.2, which had been attributed to the introduction of oxygen interstitial by Li dopant. The sensing performance and the temperature-dependent conductivity were investigated. It is observed that Li doped ZnO showed higher sensitivity and selectivity compared to the undoped ZnO. The 0.1 Li doped ZnO performed the maximum responses of 71.5 and 40.2 for 100 ppm methanol and formaldehyde, respectively, at 350 °C. The research showed that the oxygen vacancies served as active sites which supported the oxygen adsorption and reaction, oxygen interstitials served as active sites to oxidize the reducing gases and produce electrons. The enhanced sensing performance of Li doped ZnO was attributed to the synergistic effect of oxygen interstitials and oxygen vacancies.

  8. Clinical evaluation of contemporary oxygenators.

    Science.gov (United States)

    Stanzel, Roger D P; Henderson, Mark

    2016-01-01

    Advances in cardiopulmonary bypass equipment have played a critical role in improving outcomes for cardiac surgery patients. Recent advancements include reduced priming volumes, biocompatible coatings and gaseous microemboli handling, as well as the incorporation of an arterial filter into the oxygenator.The purpose of this study was to conduct a comprehensive clinical evaluation of adult oxygenators on the market. Oxygenators assessed included the Sorin Synthesis(®) (n = 30), the Sorin Inspire 6F(®) (n = 10) and Inspire 8F(®) (n = 30), the Terumo FX15(®) (n = 13) and FX25(®) (n = 30), the Maquet Quadrox-i(®) (n = 30) and the Medtronic Fusion(®) (n = 30). Parameters assessed included functional prime volumes, gas exchange, pressure gradients and the effects on patient hematology.The Synthesis had the largest functional prime volume (1426 ml), the FX15 the lowest (956 ml). The Inspire 6F, 8F and Fusion had the greatest O2 transfer. The Sorin oxygenators required the lowest sweep gas flows to obtain a PaCO2 of 40 mmHg. The Sorin oxygenators had the largest pressure gradients. While no differences were observed for hemoglobin and platelet levels post cross-clamp removal, the Sorin Synthesis and Inspire 8F had the largest increases in white blood cell (WBC) counts (122% and 141% of baseline, respectively) and neutrophils (162% and 185% of baseline, respectively).The data demonstrate that no single product is superior in all aspects. The choice of ideal oxygenator depends on the aspect(s) of oxygenator performance the perfusion team believes most clinically acceptable based on available data. © The Author(s) 2015.

  9. Computer-assisted numerical analysis for oxygen and carbon dioxide mass transfer in blood oxygenators.

    Science.gov (United States)

    Turri, Fabio; Yanagihara, Jurandir Itizo

    2011-06-01

    A two-dimensional numeric simulator is developed to predict the nonlinear, convective-reactive, oxygen mass exchange in a cross-flow hollow fiber blood oxygenator. The numeric simulator also calculates the carbon dioxide mass exchange, as hemoglobin affinity to oxygen is affected by the local pH value, which depends mostly on the local carbon dioxide content in blood. Blood pH calculation inside the oxygenator is made by the simultaneous solution of an equation that takes into account the blood buffering capacity and the classical Henderson-Hasselbach equation. The modeling of the mass transfer conductance in the blood comprises a global factor, which is a function of the Reynolds number, and a local factor, which takes into account the amount of oxygen reacted to hemoglobin. The simulator is calibrated against experimental data for an in-line fiber bundle. The results are: (i) the calibration process allows the precise determination of the mass transfer conductance for both oxygen and carbon dioxide; (ii) very alkaline pH values occur in the blood path at the gas inlet side of the fiber bundle; (iii) the parametric analysis of the effect of the blood base excess (BE) shows that (.)V(CO₂) is similar in the case of blood metabolic alkalosis, metabolic acidosis, or normal BE, for a similar blood inlet P(CO₂), although the condition of metabolic alkalosis is the worst case, as the pH in the vicinity of the gas inlet is the most alkaline; (iv) the parametric analysis of the effect of the gas flow to blood flow ratio (QG/QB) shows that (.)V(CO₂) variation with the gas flow is almost linear up to QG/QB = 2.0. (.)V(O₂) is not affected by the gas flow as it was observed that by increasing the gas flow up to eight times, the (.)V(O₂) grows only 1%. The mass exchange of carbon dioxide uses the full length of the hollow-fiber only if Q(G) /Q(B)> 2.0, as it was observed that only in this condition does the local variation of pH and blood P(CO₂) comprise the whole

  10. EVALUATING AN INNOVATIVE OXYGEN SENSOR FOR REMOTE SUBSURFACE OXYGEN MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Millings, M; Brian Riha, B; Warren Hyde, W; Karen Vangelas, K; Brian02 Looney, B

    2006-10-12

    Oxygen is a primary indicator of whether anaerobic reductive dechlorination and similar redox based processes contribute to natural attenuation remedies at chlorinated solvent contaminated sites. Thus, oxygen is a viable indicator parameter for documenting that a system is being sustained in an anaerobic condition. A team of researchers investigated the adaptation of an optical sensor that was developed for oceanographic applications. The optical sensor, because of its design and operating principle, has potential for extended deployment and sensitivity at the low oxygen levels relevant to natural attenuation. The results of the research indicate this tool will be useful for in situ long-term monitoring applications, but that the traditional characterization tools continue to be appropriate for characterization activities.

  11. Cardiogenic Shock: Failure of Oxygen Delivery and Oxygen Utilization.

    Science.gov (United States)

    Lim, Hoong Sern

    2016-08-01

    Cardiogenic shock remains a highly lethal condition. Conventional therapy including revascularization and mechanical circulatory support aims to improve cardiac output and oxygen delivery, but increasing basic and clinical observations indicate wider circulatory and cellular abnormalities, particularly at the advanced stages of shock. Progressive cardiogenic shock is associated with microcirculatory and cellular abnormalities. Cardiogenic shock is initially characterized by a failure to maintain global oxygen delivery; however, progressive cardiogenic shock is associated with the release of pro-inflammatory cytokines, derangement of the regulation of regional blood flow, microcirculatory abnormalities, and cellular dysoxia. These abnormalities are analogous to septic shock and may not be reversed by increase in oxygen delivery, even to supranormal levels. Earlier mechanical circulatory support in cardiogenic shock may limit the development of microcirculatory and cellular abnormalities.

  12. Loser Generated Content

    DEFF Research Database (Denmark)

    Petersen, Søren Mørk

    2008-01-01

    , is that the Internet functions as a double–edged sword; the infrastructure does foster democracy, participation, joy, creativity and sometimes creates zones of piracy. But, at the same time, it has become evident how this same infrastructure also enables companies easily to piggyback on user generated content......In this article [ 1 ] some of the critical aspects of Web 2.0 are mapped in relation to labor and the production of user generated content. For many years the Internet was considered an apt technology for subversion of capitalism by the Italian post–Marxists. What we have witnessed, however...

  13. Factors stimulating content marketing

    Directory of Open Access Journals (Sweden)

    Naser Azad

    2016-02-01

    Full Text Available This paper presents an empirical investigation to determine factors influencing on content marketing in banking industry. The study designs a questionnaire consists of 40 questions in Likert scale and distributes it among 550 randomly selected regular customers of Bank Mellat in city of Tehran, Iran and 400 properly filled questionnaires are collected. Cronbach alphas for all components of the survey are well above desirable level. Using principle component analysis with Varimax rotation, the study has determined six factors influencing the most on content marketing including organization, details, having new ideas, quality, sensitivity and power while the last component contains only two subcomponents and is removed from the study.

  14. Imaging of gaseous oxygen through DFB laser illumination

    Science.gov (United States)

    Cocola, L.; Fedel, M.; Tondello, G.; Poletto, L.

    2016-05-01

    A Tunable Diode Laser Absorption Spectroscopy setup with Wavelength Modulation has been used together with a synchronous sampling imaging sensor to obtain two-dimensional transmission-mode images of oxygen content. Modulated laser light from a 760nm DFB source has been used to illuminate a scene from the back while image frames were acquired with a high dynamic range camera. Thanks to synchronous timing between the imaging device and laser light modulation, the traditional lock-in approach used in Wavelength Modulation Spectroscopy was replaced by image processing techniques, and many scanning periods were averaged together to allow resolution of small intensity variation over the already weak absorption signals from oxygen absorption band. After proper binning and filtering, the time-domain waveform obtained from each pixel in a set of frames representing the wavelength scan was used as the single detector signal in a traditional TDLAS-WMS setup, and so processed through a software defined digital lock-in demodulation and a second harmonic signal fitting routine. In this way the WMS artifacts of a gas absorption feature were obtained from each pixel together with intensity normalization parameter, allowing a reconstruction of oxygen distribution in a two-dimensional scene regardless from broadband transmitted intensity. As a first demonstration of the effectiveness of this setup, oxygen absorption images of similar containers filled with either oxygen or nitrogen were acquired and processed.

  15. SUPPORTED DENSE CERAMIC MEMBRANES FOR OXYGEN SEPARATION

    Energy Technology Data Exchange (ETDEWEB)

    Timothy L. Ward

    2000-06-30

    Mixed-conducting membranes have the ability to conduct oxygen with perfect selectivity at elevated temperatures, which makes them an extremely attractive alternative for oxygen separation and membrane reactor applications. The ability to reliably fabricate these membranes in thin or thick films would enable solid-state divisional limitations to be minimized, thus providing higher oxygen flux. Based on that motivation, the overall objective for this project is to develop and demonstrate a strategy for the fabrication of supported Wick film ceramic mixed conducting membranes, and improve the understanding of the fundamental issues associated with reliable fabrication of these membranes. The project has focused on the mixed-conducting ceramic composition SrCo{sub 0.5}FeO{sub x} because of its superior permeability and stability in reducing atmospheres. The fabrication strategy employed involves the deposition of SrCo{sub 0.5}FeO{sub x} thick films onto porous supports of the same composition. In the second year of this project, we completed characterization of the sintering and phase behavior of the porous SrCo{sub 0.5}FeO{sub x} supports, leading to a standard support fabrication methodology. Using a doctor blade method, pastes made from aerosol-derived SrCo{sub 0.5}FeO{sub x} powder dispersed with polyethylene glycol were applied to the supports, and the sintering behavior of the thick film membranes was examined in air and nitrogen atmospheres. It has been demonstrated that the desired crystalline phase content can be produced in the membranes, and that the material in the membrane layer can be highly densified without densifying the underlying support. However, considerable cracking and opening of the film occurred when films densified to a high extent. The addition of MgO into the SrCo{sub 0.5}FeO{sub x} supports was shown to inhibit support sintering so that temperatures up to 1300 C, where significant liquid formation occurs, could be used for film sintering

  16. Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

    Science.gov (United States)

    Kelly, Mark; Pettit, Donald

    2003-01-01

    A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

  17. Sedimentary pigments and nature of organic matter within the oxygen minimum zone (OMZ) of the Eastern Arabian Sea (Indian margin)

    Digital Repository Service at National Institute of Oceanography (India)

    Rasiq, K.T.; Kurian, S.; Karapurkar, S.G.; Naqvi, S.W.A.

    Sedimentary pigments, carbon and nitrogen content and their stable isotopes were studied in three short cores collected from the oxygen minimum zone (OMZ) of the Eastern Arabian Sea (EAS). Nine pigments including chlorophyll a and their degradation...

  18. The Effect of Ash and Inorganic Pigment Fill on the Atomic Oxygen Erosion of Polymers and Paints (ISMSE-12)

    Science.gov (United States)

    Banks, Bruce A.; Simmons, Julie C.; de Groh, Kim K.; Miller, Sharon K.

    2012-01-01

    Low atomic oxygen fluence (below 1x10(exp 20) atoms/sq cm) exposure of polymers and paints that have a small ash content and/or inorganic pigment fill does not cause a significant difference in erosion yield compared to unfilled (neat) polymers or paints. However, if the ash and/or inorganic pigment content is increased, the surface population of the inorganic content will begin to occupy a significant fraction of the surface area as the atomic oxygen exposure increases because the ash is not volatile and remains as a loosely attached surface layer. This results in a reduction of the flux of atomic oxygen reacting with the polymer and a reduction in the rate of erosion of the polymer remaining. This paper presents the results of ground laboratory and low Earth orbital (LEO) investigations to evaluate the fluence dependence of atomic oxygen erosion yields of polymers and paints having inorganic fill content.

  19. Assessment of microalgae and nitrifiers activity in a consortium in a continuous operation and the effect of oxygen depletion

    Directory of Open Access Journals (Sweden)

    Gustavo Vargas

    2016-09-01

    Conclusions: The consortium it can be obtained in a single continuous operation, and has a high capacity for nitrogen removal with low oxygen content. The consortium could prove to be a more economical method compared to traditional.

  20. Tourist-created Content

    DEFF Research Database (Denmark)

    Munar, Ana Maria

    2011-01-01

    Purpose – The purpose of this paper is to analyze the relationship between tourists' user-generated content on the web and destination branding, as well as to discuss the online strategies used by destination management organizations. Design/methodology/approach – The research adopts an explorato...

  1. Where's the Content?

    Science.gov (United States)

    Fitzhugh, Will

    2006-01-01

    Although teachers focus on style, fluency, tone, and correct grammar in writing, they rarely emphasize the importance of content. Both the National Commission on Writing in America's Schools and Colleges and the NAEP seem to favor emotional and personal writing, at least at the high school level. Judging from their guidelines, both the SAT and the…

  2. Content Management Systems

    Science.gov (United States)

    Wisniewski, Jeff; Stenstrom, Cheryl

    2007-01-01

    In this article, the authors provide a guide in acquiring content management system. They conducted a vendor survey that covers four areas: (1) general information about the product (including standards supported); (2) administration of the product; (3) functionality; and (4) contact information for readers who want to know more. A list of product…

  3. Contents & Abstracts

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Does Globalization Widen or Narrow the Income Inequality in China?Knowledge Composition, Emigration and Economic Growth,China's Status in Division of Labor in the World: A Multinational Analysis based on the Whole and Domestic Technological Contents of Exports

  4. Table of contents

    African Journals Online (AJOL)

    J. S. Nyombo Luboya

    C. Drying with salt results in a nutritionally and organoleptically good product, ... studies are recommended to assess whether there is variation in nutrient and ... Though nutritious, SPL have been considered a poor man's salad [2,4]. ... The vegetables were mixed every minute and a small amount .... Iron content was much.

  5. Mathematics: Content and Pedagogy

    Science.gov (United States)

    Ediger, Marlow

    2009-01-01

    The debate has gone on for some time in terms of which is more salient for the teacher to be well versed in, mathematical content versus methods and approaches in teaching. Both are salient. They cannot be separated from each other. The mathematics teacher must indeed have broad, in-depth knowledge of subject matter as well as in teaching and…

  6. Integrating Language and Content

    Science.gov (United States)

    Nordmeyer, Jon, Ed.; Barduhn, Susan, Ed.

    2010-01-01

    The definition of "English language classroom" is changing. When students have the opportunity to learn content and language at the same time, disciplinary boundaries overlap. Teachers are rethinking how they design courses, plan lessons, assess students, and collaborate with colleagues to support student learning and facilitate their…

  7. Content Area Vocabulary Learning

    Science.gov (United States)

    Fisher, Douglas; Frey, Nancy

    2014-01-01

    Students' vocabulary knowledge is a significant predictor of their overall comprehension. The Common Core State Standards are raising the expectations for word learning and there are now 4 distinct standards related to vocabulary as well as expectations in other standards, including content areas. To address these expectations, teachers need…

  8. Contents & Abstracts

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Electrochemical Behavior and Corrosion Resistance of Electroplated Nickel- Phosphorus/Nanometer Silicon Carbide Composite Coating;Effect of Curing Temperature on Corrosion Resistance of Sodium Silicate Conversion Antirust Coating;Effect of Silicon Content on Solidified Structure and Corrosion Resistance of Hot - Dipped Zinc - 40% Aluminum Alloy Coating

  9. 21 CFR 868.5580 - Oxygen mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxygen mask. 868.5580 Section 868.5580 Food and... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5580 Oxygen mask. (a) Identification. An oxygen mask is a device placed over a patient's nose, mouth, or tracheostomy to administer oxygen or aerosols. (b)...

  10. The oxygen content of ocean bottom waters, the burial efficiency of organic carbon, and the regulation of atmospheric oxygen

    Science.gov (United States)

    Betts, J. N.; Holland, H. D.

    1991-01-01

    Data for the burial efficiency of organic carbon with marine sediments have been compiled for 69 locations. The burial efficiency as here defined is the ratio of the quantity of organic carbon which is ultimately buried to that which reaches the sediment-water interface. As noted previously, the sedimentation rate exerts a dominant influence on the burial efficiency. The logarithm of the burial efficiency is linearly related to the logarithm of the sedimentation rate at low sedimentation rates. At high sedimentation rates the burial efficiency can exceed 50% and becomes nearly independent of the sedimentation rate. The residual of the burial efficiency after the effect of the sedimentation rate has been subtracted is a weak function of the O2 concentration in bottom waters. The scatter is sufficiently large, so that the effect of the O2 concentration in bottom waters on the burial efficiency of organic matter could be either negligible or a minor but significant part of the mechanism that controls the level of O2 in the atmosphere.

  11. HYPERBARIC OXYGENATION AND AEROBIC PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Irvine D. Prather

    2004-03-01

    Full Text Available The continuing desire to improve performance, particularly at the national and international levels, has led to the use of ergogenic aids. Ergogenic aids are defined as 'a procedure or agent that provides the athlete with a competitive edge beyond that obtained via normal training methods'. Random drug testing has been implemented in an effort to minimize an athlete's ability to gain an unfair advantage. However, other means of improving performance have been tried. Blood doping has been used to enhance endurance performance by improving oxygen delivery to working muscles. As oxygen is carried in combination with the hemoglobin, it seems logical that increasing the number of red blood cells (RBC's in the body would increase the oxygen carrying capacity to the tissues and result in improved performance. The first experiments of removing and then reinfusing blood showed a significant improvement in performance time

  12. A novel method to control oxygen stoichiometry and thermoelectric properties in (RE)BaCo2O5+

    Indian Academy of Sciences (India)

    T Dasgupta; S Sumithra; A M Umarji

    2008-11-01

    Rare earth cobaltites of the type (RE)BaCo2O5+ (RE = Y, Gd, Eu and Nd) were synthesized by solid state technique. A novel, fast quenching technique was used to tune the oxygen content in these compounds. Room temperature Seebeck and electrical resistivity measurements were used to infer the oxygen content. A maximum in the and ρ was observed for all the compositions when value was close to 0.5.

  13. IMPACT OF OXYGENATED FUEL ON DIESEL ENGINE PERFORMANCE AND EMISSIONS

    Energy Technology Data Exchange (ETDEWEB)

    Boehman, Andre L.

    2000-08-20

    As evidenced by recent lawsuits brought against operators of large diesel truck fleets [1] and by the Consent Decree brought against the heavy-duty diesel manufacturers [2], the environmental and health effects of diesel engine emissions continue to be a significant concern. Reduction of diesel engine emissions has traditionally been achieved through a combination of fuel system, combustion chamber, and engine control modifications [3]. Catalytic aftertreatment has become common on modern diesel vehicles, with the predominant device being the diesel oxidation catalytic converter [3]. To enable advanced after-treatment devices and to directly reduce emissions, significant recent interest has focused on reformulation of diesel fuel, particularly the reduction of sulfur content. The EPA has man-dated that diesel fuel will have only 15 ppm sulfur content by 2007, with current diesel specifications requiring around 300 ppm [4]. Reduction of sulfur will permit sulfur-sensitive aftertreatment devices, continuously regenerating particulate traps, NOx control catalysts, and plasma assisted catalysts to be implemented on diesel vehicles [4]. Another method of reformulating diesel fuel to reduce emissions is to incorporate oxygen in the fuel, as was done in the reformulation of gasoline. The use of methyl tertiary butyl ether (MTBE) in reformulated gasoline has resulted in contamination of water resources across the country [5]. Nonetheless, by relying on the lessons learned from MTBE, oxygenation of diesel fuel may be accomplished without compromising water quality. Oxygenation of diesel fuel offers the possibility of reducing particulate matter emissions significantly, even for the current fleet of diesel vehicles. The mechanism by which oxygen content leads to particulate matter reductions is still under debate, but recent evidence shows clearly that ''smokeless'' engine operation is possible when the oxygen content of diesel fuel reaches roughly 38% by

  14. A Theory of Atmospheric Oxygen

    OpenAIRE

    2015-01-01

    There is no direct geologic record of the level of free oxygen in the atmosphere over Earth history. Indirect proxy records have led to a canonical view of atmospheric pO2, according to which the atmosphere has passed through three stages. During the first of these periods, corresponding roughly to the Archean eon, pO2 was less than 0.001% present atmospheric levels (PAL). Oxygen levels rose abruptly around 2.4 billion years ago, a transition referred to as the “Great Oxidation Event” (GOE...

  15. High Temperature Sorbents for Oxygen

    Science.gov (United States)

    Sharma, Pramod K. (Inventor)

    1996-01-01

    A sorbent capable of removing trace amounts of oxygen (ppt) from a gas stream at a high temperature above 200 C is introduced. The sorbent comprises a porous alumina silicate support such as zeolite containing from 1 to 10 percent by weight of ion exchanged transition metal such as copper or cobalt ions and 0.05 to 1.0 percent by weight of an activator selected from a platinum group metal such as platinum. The activation temperature, oxygen sorption and reducibility are all improved by the presence of the platinum activator.

  16. Investigation of oxygen defects in wurtzite InN by using density functional theory

    Science.gov (United States)

    Hattori, Y.; Chubaci, J. F. D.; Matsuoka, M.; Freitas, J. A.; da Silva, A. Ferreira

    2016-12-01

    Density Functional Theory based on ab initio calculations was employed to investigate single and complex defects of oxygen in indium nitride and their influence on the optical properties. Different oxygen contents (x=1.38%, 4.16%, 5.55% and 11.11%) were considered in our study by using PBEsol-GGA and TB-mBJ for the treatment of exchange-correlation energy and potential. It was found that oxygen is energetically favorable to exist mainly as singly charged isolated defect. The results using TB-mBJ approximation predicts a narrowing of the VBM (valence band maximum) and CBM (conduction band minimum) as oxygen content increases. Nevertheless, the larger contribution of the Moss-Burstein effect leads to an effective band-gap increase, yielding absorption edge values larger than that of the intrinsic bulk indium nitride.

  17. Effect of Controlled Freezing and Open-Pulled Straw (OPS) Vitrification on ATP Content and Reactive Oxygen Species (ROS) Level of Bovine In Vitro Produced Blastocysts%不同冷冻方法对牛体外胚胎ATP含量与ROS水平的影响

    Institute of Scientific and Technical Information of China (English)

    赵学明; 杜卫华; 王栋; 郝海生; 朱化彬

    2012-01-01

    [Objective] The experiment was designed to investigate the effect of cryopreservation on ATP content and ROS level of bovine blastocysts produced by in vitro fertilization (IVF) and somatic cell nuclear transfer (SCNT). [Method] Bovine in vitro produced blastocysts were cryopreserved by controlled freezing and OPS vitrification. ATP Bioluminescence Assay Kit HS II and GENMED ROS Assay Kit were used to analyze ATP content and ROS level in cryopreserved blastocysts. [Result] (1) For each kind of blastocysts (IVF or SCNT), significant difference was observed between survival rates of controlled freezing group ((81.25±4.98)% or (49.41±2.24)%) and OPS vitrification group ((93.25±5.17)% or (77.56±3.52)%) (P<0.05). (2) For IVF blastocysts, ATP content was significantly decreased from (0.76±0.04) pmol (fresh group) to (0.45±0.03) pmol (controlled freezing group) or (0.63±0.05) pmol (vitrification group) (P<0.05), and the same was found for SCNT blastocysts ((0.40±0.02) pmol to (0.22±0.01) pmol or (0.33±0.02) pmol) (P<0.05). ATP content of each kind of blastocysts (IVF or SCNT) in controlled freezing group ((0.45±0.03) pmol or (0.22±0.01) pmol) was significantly lower than that in OPS vitrification group ((0.63±0.05) pmol or (0.33±0.02) pmol) (P<0.05). (3) ROS level of fresh IVF blastocysts ((48.52±2.65) cps) or SCNT blastocysts ((27.36±2.23) cps) was significantly lower than that of OPS vitrification group ((74.34±4.24) cps or (43.21±3.35) cps) (P<0.05), but higher than that of controlled freezing group ((35.61±4.32) cps or (16.56±2.52) cps) (P<0.05). [Conclusion] The present work indicated that vitrification was more efficient in the cryopreservation of bovine blastocysts derived from FVF or SCNT with comparison of controlled freezing. Meanwhile, both vitrification and controlled freezing significantly altered ATP content and ROS level in those blastocysts.%[目的]探讨冷冻保存对牛体外生产胚胎能量代谢、有氧代谢造成的影响.[

  18. Differentiating the role of lithium and oxygen in retaining deuterium on lithiated graphite plasma-facing components

    Energy Technology Data Exchange (ETDEWEB)

    C.N. Taylor; J. P. Allain; P. S. Krstic; J. Dadras; C. H. Skinner; K. E. Luitjohan

    2013-11-01

    Laboratory experiments have been used to investigate the fundamental interactions responsible for deuterium retention in lithiated graphite. Oxygen was found to be present and play a key role in experiments that simulated NSTX lithium conditioning, where the atomic surface concentration can increase to >40% when deuterium retention chemistry is observed. Quantum-classical molecular dynamic simulations elucidated this oxygen-deuterium effect and showed that oxygen retains significantly more deuterium than lithium in a simulated matrix with 20% lithium, 20% oxygen, and 60% carbon. Simulations further show that deuterium retention is even higher when lithium is removed from the matrix. Experiments artificially increased the oxygen content in graphite to approximately 16% and then bombarded with deuterium. XPS showed depletion of the oxygen and no enhanced deuterium retention, thus demonstrating that lithium is essential in retaining the oxygen that thereby retains deuterium.

  19. Effect of xinmailong on metabolism of oxygen free radicals and content of lipofuscin in brain and hepatic tissues%心脉龙干预后氧自由基代谢及脑、肝组织脂褐质含量的变化

    Institute of Scientific and Technical Information of China (English)

    吴建新; 钮荣祥; 黄秀群; 田昆仑; 董丛丽

    2006-01-01

    dismutase (SOD) and glutathione peroxidase (GSH-Px) in serum, content of malondialdehyde (MDA) in brain tissue and content of lipofuscin in cerebral and hepatic tissue were measured according to introduction of kits.MAIN OUTCOME MEASURES: ① Activities of CAT, SOD and GSHPx in serum; ② content of MDA in brain tissue and contents of lipofuscin in cerebral and hepatic tissues.RFSULTS: A total of 40 animals were involved in the final analysis without any loss. ① Activities of CAT, SOD and GSH-Px in serum of mice were lower in aging control group than those in young control group; however,activities of CAT, SOD and GSH-Px in serum of mice were increased in the two XML dosage groups, and there was significant difference from those in aging control group (P < 0.05 or P < 0.01). ② Content of MDA in brain tissue and contents of lipofuscin in cerebral and hepatic tissues of mice in aging control group were higher than those of mice in young control group, but those in the two dosage groups were decreased, which was significant difference from those of mice in aging control group (P < 0.01). However, there was no significant difference between the two dosage groups.CONCLUSION: XML has an effect on anti-aging through improving metabolism of free radicals.

  20. Towards Multimodal Content Representation

    CERN Document Server

    Bunt, Harry

    2009-01-01

    Multimodal interfaces, combining the use of speech, graphics, gestures, and facial expressions in input and output, promise to provide new possibilities to deal with information in more effective and efficient ways, supporting for instance: - the understanding of possibly imprecise, partial or ambiguous multimodal input; - the generation of coordinated, cohesive, and coherent multimodal presentations; - the management of multimodal interaction (e.g., task completion, adapting the interface, error prevention) by representing and exploiting models of the user, the domain, the task, the interactive context, and the media (e.g. text, audio, video). The present document is intended to support the discussion on multimodal content representation, its possible objectives and basic constraints, and how the definition of a generic representation framework for multimodal content representation may be approached. It takes into account the results of the Dagstuhl workshop, in particular those of the informal working group...

  1. Content Based Video Retrieval

    Directory of Open Access Journals (Sweden)

    B. V. Patel

    2012-10-01

    Full Text Available Content based video retrieval is an approach for facilitating the searching and browsing of large image collections over World Wide Web. In this approach, video analysis is conducted on low level visual properties extracted from video frame. We believed that in order to create an effective video retrieval system, visual perception must be taken into account. We conjectured that a technique which employs multiple features for indexing and retrieval would be more effective in the discrimination and search tasks of videos. In order to validate this claim, content based indexing and retrieval systems were implemented using color histogram, various texture features and other approaches. Videos were stored in Oracle 9i Database and a user study measured correctness of response.

  2. Web Content Filtering

    OpenAIRE

    Gómez Hidalgo, José María; Puertas Sanz, Enrique; Carrero García, Francisco Manuel; Buenaga Rodríguez, Manuel de

    2009-01-01

    Across the years, Internet has evolved from an academic network to a truly communication medium, reaching impressive levels of audience and becoming a billionaire business. Many of our working, studying, and entertainment activities are nowadays overwhelmingly limited if we get disconnected from the net of networks. And of course, with the use comes abuse. The World Wide Web features a wide variety of content that are harmful for children or just inappropriate in the workplace. Web filtering ...

  3. Twitter content classification

    OpenAIRE

    2010-01-01

    This paper delivers a new Twitter content classification framework based sixteen existing Twitter studies and a grounded theory analysis of a personal Twitter history. It expands the existing understanding of Twitter as a multifunction tool for personal, profession, commercial and phatic communications with a split level classification scheme that offers broad categorization and specific sub categories for deeper insight into the real world application of the service.

  4. Trends in oxygen reduction and methanol activation on transition metal chalcogenides

    DEFF Research Database (Denmark)

    Tritsaris, Georgios; Nørskov, Jens Kehlet; Rossmeisl, Jan

    2011-01-01

    We use density functional theory calculations to study the oxygen reduction reaction and methanol activation on selenium and sulfur-containing transition metal surfaces. With ruthenium selenium as a starting point, we study the effect of the chalcogen on the activity, selectivity and stability...... of the catalyst. Ruthenium surfaces with moderate content of selenium are calculated active for the oxygen reduction reaction, and insensitive to methanol. A significant upper limit for the activity of transition metal chalcogenides is estimated....

  5. Characterization and Electrochemical Properties of Oxygenated Amorphous Carbon (a-C) Films

    OpenAIRE

    Palomäki, Tommi; Wester, Niklas; Johansson, Leena-Sisko; Laitinen, Mikko; Jiang, Hua; Arstila, Kai; Sajavaara, Timo; Han, Jeon G.; Koskinen, Jari; Laurila, Tomi

    2016-01-01

    Amorphous carbon (a-C) films with varying oxygen content were deposited by closed-field unbalanced magnetron sputtering with the aim to understand the effect of oxygen on the structural and physical properties of the films and subsequently correlate these changes with electrochemical properties. The a-C films were characterized by transmission electron microscopy, helium-ion microscopy, atomic force microscopy, Raman spectroscopy, X-ray photoelectron spectroscopy and time-of-flight elastic re...

  6. Dependence of the solubility of atmospheric oxygen in weakly alkaline aqueous solutions on surfactant concentration

    Science.gov (United States)

    Chistyakova, G. V.; Koksharov, S. A.; Vladimirova, T. V.

    2012-11-01

    The solubility of atmospheric oxygen in solutions of surfactants of different natures at 293 K and pH 8 is determined by gas chromatography. It is found that additives of nonionic surfactants decrease the oxygen content in the solution in the premicellar region and increase its solubility in the micellar region. It is shown that, for anionic surfactants, a decrease in the solubility of O2 is observed over the entire concentration range.

  7. Towards Network-Failure-Tolerant Content Delivery for Web Content

    OpenAIRE

    Hu, Wen; Wang, Zhi; Sun, Lifeng

    2016-01-01

    Popularly used to distribute a variety of multimedia content items in today Internet, HTTP-based web content delivery still suffers from various content delivery failures. Hindered by the expensive deployment cost, the conventional CDN can not deploy as many edge servers as possible to successfully deliver content items to all users under these delivery failures. In this paper, we propose a joint CDN and peer-assisted web content delivery framework to address the delivery failure problem. Dif...

  8. Content Documents Management

    Science.gov (United States)

    Muniz, R.; Hochstadt, J.; Boelke J.; Dalton, A.

    2011-01-01

    The Content Documents are created and managed under the System Software group with. Launch Control System (LCS) project. The System Software product group is lead by NASA Engineering Control and Data Systems branch (NEC3) at Kennedy Space Center. The team is working on creating Operating System Images (OSI) for different platforms (i.e. AIX, Linux, Solaris and Windows). Before the OSI can be created, the team must create a Content Document which provides the information of a workstation or server, with the list of all the software that is to be installed on it and also the set where the hardware belongs. This can be for example in the LDS, the ADS or the FR-l. The objective of this project is to create a User Interface Web application that can manage the information of the Content Documents, with all the correct validations and filters for administrator purposes. For this project we used one of the most excellent tools in agile development applications called Ruby on Rails. This tool helps pragmatic programmers develop Web applications with Rails framework and Ruby programming language. It is very amazing to see how a student can learn about OOP features with the Ruby language, manage the user interface with HTML and CSS, create associations and queries with gems, manage databases and run a server with MYSQL, run shell commands with command prompt and create Web frameworks with Rails. All of this in a real world project and in just fifteen weeks!

  9. Determination of Fat Content

    Science.gov (United States)

    Carpenter, Charles

    The term "lipid" refers to a group of compounds that are sparingly soluble in water, but show variable solubility in a number of organic solvents (e.g., ethyl ether, petroleum ether, acetone, ethanol, methanol, benzene). The lipid content of a food determined by extraction with one solvent may be quite different from the lipid content as determined with another solvent of different polarity. Fat content is determined often by solvent extraction methods (e.g., Soxhlet, Goldfish, Mojonnier), but it also can be determined by nonsolvent wet extraction methods (e.g., Babcock, Gerber), and by instrumental methods that rely on the physical and chemical properties of lipids (e.g., infrared, density, X-ray absorption). The method of choice depends on a variety of factors, including the nature of the sample (e.g., dry versus moist), the purpose of the analysis (e.g., official nutrition labeling or rapid quality control), and instrumentation available (e.g., Babcock uses simple glassware and equipment; infrared requires an expensive instrument).

  10. Biotechnological sulphide removal with oxygen

    NARCIS (Netherlands)

    Buisman, C.

    1989-01-01

    This thesis deals with the development of a new process for biotechnological sulphide removal from wastewater, in which it is attempted to convert sulphide into elemental sulphur by colourless sulphur bacteria. The toxicity, corrosive properties, unpleasant odor and high oxygen demand of sulphide di

  11. Oxygen therapy reduces postoperative tachycardia

    DEFF Research Database (Denmark)

    Stausholm, K; Kehlet, H; Rosenberg, J

    1995-01-01

    Concomitant hypoxaemia and tachycardia in the postoperative period is unfavourable for the myocardium. Since hypoxaemia per se may be involved in the pathogenesis of postoperative tachycardia, we have studied the effect of oxygen therapy on tachycardia in 12 patients randomly allocated to blinded...

  12. Oxygen dynamics in the aftermath of the Great Oxidation of Earth’s atmosphere

    Science.gov (United States)

    Canfield, Donald E.; Ngombi-Pemba, Lauriss; Hammarlund, Emma U.; Bengtson, Stefan; Chaussidon, Marc; Gauthier-Lafaye, François; Meunier, Alain; Riboulleau, Armelle; Rollion-Bard, Claire; Rouxel, Olivier; Asael, Dan; Pierson-Wickmann, Anne-Catherine; El Albani, Abderrazak

    2013-01-01

    The oxygen content of Earth’s atmosphere has varied greatly through time, progressing from exceptionally low levels before about 2.3 billion years ago, to much higher levels afterward. In the absence of better information, we usually view the progress in Earth’s oxygenation as a series of steps followed by periods of relative stasis. In contrast to this view, and as reported here, a dynamic evolution of Earth’s oxygenation is recorded in ancient sediments from the Republic of Gabon from between about 2,150 and 2,080 million years ago. The oldest sediments in this sequence were deposited in well-oxygenated deep waters whereas the youngest were deposited in euxinic waters, which were globally extensive. These fluctuations in oxygenation were likely driven by the comings and goings of the Lomagundi carbon isotope excursion, the longest–lived positive δ13C excursion in Earth history, generating a huge oxygen source to the atmosphere. As the Lomagundi event waned, the oxygen source became a net oxygen sink as Lomagundi organic matter became oxidized, driving oxygen to low levels; this state may have persisted for 200 million years. PMID:24082125

  13. Low oxygen alters mitochondrial function and response to oxidative stress in human neural progenitor cells

    Directory of Open Access Journals (Sweden)

    Yury M. Lages

    2015-12-01

    Full Text Available Oxygen concentration should be carefully regulated in all living tissues, beginning at the early embryonic stages. Unbalances in oxygen regulation can lead to cell death and disease. However, to date, few studies have investigated the consequences of variations in oxygen levels for fetal-like cells. Therefore, in the present work, human neural progenitor cells (NPCs derived from pluripotent stem cells grown in 3% oxygen (v/v were compared with NPCs cultured in 21% (v/v oxygen. Low oxygen concentrations altered the mitochondrial content and oxidative functions of the cells, which led to improved ATP production, while reducing generation of reactive oxygen species (ROS. NPCs cultured in both conditions showed no differences in proliferation and glucose metabolism. Furthermore, antioxidant enzymatic activity was not altered in NPCs cultured in 3% oxygen under normal conditions, however, when exposed to external agents known to induce oxidative stress, greater susceptibility to DNA damage was observed. Our findings indicate that the management of oxygen levels should be considered for in vitro models of neuronal development and drug screening.

  14. Diffusion of oxygen in cork.

    Science.gov (United States)

    Lequin, Sonia; Chassagne, David; Karbowiak, Thomas; Simon, Jean-Marc; Paulin, Christian; Bellat, Jean-Pierre

    2012-04-01

    This work reports measurements of effective oxygen diffusion coefficient in raw cork. Kinetics of oxygen transfer through cork is studied at 298 K thanks to a homemade manometric device composed of two gas compartments separated by a cork wafer sample. The first compartment contains oxygen, whereas the second one is kept under dynamic vacuum. The pressure decrease in the first compartment is recorded as a function of time. The effective diffusion coefficient D(eff) is obtained by applying Fick's law to transient state using a numerical method based on finite differences. An analytical model derived from Fick's law applied to steady state is also proposed. Results given by these two methods are in close agreement with each other. The harmonic average of the effective diffusion coefficients obtained from the distribution of 15 cork wafers of 3 mm thickness is 1.1 × 10(-9) m(2) s(-1) with a large distribution over four decades. The statistical analysis of the Gaussian distribution obtained on a 3 mm cork wafer is extrapolated to a 48 mm cork wafer, which length corresponds to a full cork stopper. In this case, the probability density distribution gives a mean value of D(eff) equal to 1.6 × 10(-9) m(2) s(-1). This result shows that it is possible to obtain the effective diffusion coefficient of oxygen through cork from short time (few days) measurements performed on a thin cork wafer, whereas months are required to obtain the diffusion coefficient for a full cork stopper. Permeability and oxygen transfer rate are also calculated for comparison with data from other studies.

  15. Effect of Inert Gases on Ozone Generation Using Dielectric Barrier Discharge in Oxygen

    Institute of Scientific and Technical Information of China (English)

    WEI Linsheng; TAN Zhihong

    2012-01-01

    This paper reports the results of an experimental study of the effect of inert gases He, Ar and Kr on ozone generation in a Dielectric Barrier Discharge (DBD) fed by pure oxygen. The chemical reaction mechanisms related to the process of ozone generation are discussed. The experimental results show that ozone concentration decrease with decreasing oxygen content in all He+ 02, Ar+02 and Kr + O2 mixtures mainly owing to the decrease of oxygen content. The conversion ratio of oxygen into ozone increases with increasing oxygen content in He+O2 mixtures, but the addition of Ar and Kr can improve the conversion ratio due to the increase of free electrons density and excited oxygen molecules required for ozone formation through ionization and Penning effect. The effect of Kr is more significant for the lower first ionization energy of metastable state compared with other gases. It is probable that the ozone concentration, and ozone production efficiency increase with Kr addition when the reduced electric field and mean electron energy are high enough.

  16. MO-G-BRF-06: Radiotherapy and Prompt Oxygen Dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Kissick, M; Campos, D; Adamson, E; Niles, D; Torres, A; L, Che Fru; Kimple, R; Fain, S; Kogel, A van der [University of Wisconsin - Madison, Madison, WI (United States); Jacques, S [Oregon Health ' Science University, Portland, OR (United States)

    2014-06-15

    Purpose: Adaptive radiotherapy requires a knowledge of the changing local tumor oxygen concentrations for times on the order of the treatment time, a time scale far shorter than cell death and proliferation. This knowledge will be needed to guide hypofractionated radiotherapy. Methods: A diffuse optical probe system was developed to spatially average over the whole interior of athymic Sprague Dawley nude mouse xenografts of human head and neck cancers. The blood volume and hemoglobin saturation was measured in real time. The quantities were measured with spectral fitting before and after 10 Gy of radiation is applied. An MRI BOLD scan is acquired before and after 10 Gy that measures regional changes in R2* which is inversely proportional to oxygen availability. Simulations were performed to fit the blood oxygen dynamics and infer changes in hypoxia within the tumor. Results: The optical probe measured nearly constant blood volume and a significant drop in hemoglobin saturation of about 30% after 10 Gy over the time scale of less than 30 minutes. The averaged R2* within the tumor volume increased by 15% after the 10 Gy dose, which is consistent with the optical results. The simulations and experiments support likely dynamic metabolic changes and/or fast vasoconstrictive signals are occurring that change the oxygen concentrations significantly, but not cell death or proliferation. Conclusion: Significant oxygen changes were observed to occur within 30 minutes, coinciding with the treatment time scale. This dynamic is very important for patient specific adaptive therapy. For hypofractionated therapy, the local instantaneous oxygen content is likely the most important variable to control. The invention of a bedside device for the purpose of measuring the instantaneous response to large radiation doses would be an important step to future improvements in outcome.

  17. Tracing the stepwise oxygenation of the Proterozoic ocean.

    Science.gov (United States)

    Scott, C; Lyons, T W; Bekker, A; Shen, Y; Poulton, S W; Chu, X; Anbar, A D

    2008-03-27

    Biogeochemical signatures preserved in ancient sedimentary rocks provide clues to the nature and timing of the oxygenation of the Earth's atmosphere. Geochemical data suggest that oxygenation proceeded in two broad steps near the beginning and end of the Proterozoic eon (2,500 to 542 million years ago). The oxidation state of the Proterozoic ocean between these two steps and the timing of deep-ocean oxygenation have important implications for the evolutionary course of life on Earth but remain poorly known. Here we present a new perspective on ocean oxygenation based on the authigenic accumulation of the redox-sensitive transition element molybdenum in sulphidic black shales. Accumulation of authigenic molybdenum from sea water is already seen in shales by 2,650 Myr ago; however, the small magnitudes of these enrichments reflect weak or transient sources of dissolved molybdenum before about 2,200 Myr ago, consistent with minimal oxidative weathering of the continents. Enrichments indicative of persistent and vigorous oxidative weathering appear in shales deposited at roughly 2,150 Myr ago, more than 200 million years after the initial rise in atmospheric oxygen. Subsequent expansion of sulphidic conditions after about 1,800 Myr ago (refs 8, 9) maintained a mid-Proterozoic molybdenum reservoir below 20 per cent of the modern inventory, which in turn may have acted as a nutrient feedback limiting the spatiotemporal distribution of euxinic (sulphidic) bottom waters and perhaps the evolutionary and ecological expansion of eukaryotic organisms. By 551 Myr ago, molybdenum contents reflect a greatly expanded oceanic reservoir due to oxygenation of the deep ocean and corresponding decrease in sulphidic conditions in the sediments and water column.

  18. The analysis of cerebro-vascular circulation time using digital subtraction angiography (DSA)

    Energy Technology Data Exchange (ETDEWEB)

    Han, D. G.; Kim, D. H.; Lee, H. K.; Kwon, K. H.; Kim, K. J. [Soonchunhyang University College of Medicine, Asan (Korea, Republic of)

    1986-10-15

    We analyzed the cerebral arterio-venous circulation time of 141 cases of cranial DSA in 136 patients, for the assessment of cerebral circulatory dynamics. IV-DSA was 111 cases, IA-DSA 30 cases. The results were as follows: 1. There was no significant difference in arterio-venous circulation time between IA-DSA and IV-DSA, if the disease pattern was not considered (P > 0.1). 2. Prolongation of arterio-venous circulation time was noted in the cases of cerebral (cerebellar) hemorrhage, subarachnoid hemorrhage, intracranial hematoma, brain abscess, acute stage of cerebra-vascular occlusive disease, acute stage of postoperative follow up, and acute stage of cerebral contusion (p > 0.05). 3. Compared the chronic stage of cerebra-vascular occlusive disease, postoperative follow up, and cerebral contusion with acute stage, significant decrement of arterio-venous circulation time was resulted (p > 0.05). 4. DSA was a useful modality for the assessment of circulatory dynamics, including measurement of arterio-venous circulation time.

  19. Rat Model of Parkes Weber Syndrome.

    Directory of Open Access Journals (Sweden)

    Krzysztof Bojakowski

    Full Text Available The Parkes Weber syndrome is a congenital vascular malformation, characterized by varicose veins, arterio-venous fistulas and overgrown limbs. No broadly accepted animal model of Parkes Weber syndrome has been described. We created side-to-side arterio-venous fistula between common femoral vessels with proximal non-absorbable ligature on common femoral vein limiting the enlargement of the vein diameter in Wistar rats. Contralateral limb was sham operated. Invasive blood pressure measurements in both iliac and inferior cava veins were performed in rats 30 days after fistula creation. Tight circumference and femoral bone length were measured. Histopathology and morphology of soleus muscle, extensor digitorum longus muscle, and the common femoral vessel were analyzed. 30 days following arterio-venous fistula creation, a statistically significant elevation of blood pressure in common iliac vein and limb overgrowth was observed. Limb enlargement was caused by muscle overgrowth, varicose veins formation and bone elongation. Arterio-venous fistula with proximal outflow limitation led to significant increase of femoral vein circumference and venous wall thickness. Our study indicates that the described rat model mimics major clinical features characteristic for the human Parkes Weber syndrome: presence of arterio-venous fistula, venous hypertension and dilatation, varicose veins formation, and the limb hypertrophy. We reveal that limb overgrowth is caused by bone elongation, muscle hypertrophy, and venous dilatation. The newly established model will permit detailed studies on the mechanisms underlying the disease and on the efficacy of novel therapeutic strategies for the Parkes Weber syndrome treatment.

  20. Content Marketing Practices in Finland

    OpenAIRE

    Suuronen, Toni

    2016-01-01

    The purpose of this study is to draw attention to increasingly important business phenomenon of content marketing. This paper defines content marketing, identifies its key elements and phases, and explores content marketing practices. The theorethical part is based on Pam Didner's 4P model that describes the stages of content marketing cycle: plan, produce, promote and perfect. The empirical part of the study is based on semi-structured interviews of seasoned content marketing professionals t...

  1. Oxygen supply and consumption in soilless culture: evaluation of an oxygen simulation model for cucumber

    NARCIS (Netherlands)

    Baas, R.; Wever, G.; Koolen, A.J.; Tariku, E.; Stol, K.J.

    2001-01-01

    A soil oxygen simulation model (OXSI) was tested and evaluated for evaluating growing media with respect to aeration. In the model, local oxygen concentrations are calculated from coefficients of diffusion and consumption (respiration), assuming equilibrium conditions. Apparent oxygen diffusion coef

  2. Synthesis gas production using oxygen storage materials as oxygen carrier over circulating fluidized bed

    Institute of Scientific and Technical Information of China (English)

    DAI Xiaoping; YU Changchun; LI Ranjia; WU Qiong; HAO Zhengping

    2008-01-01

    A novel process for synthesis gas production over Circulating Fluidized Bed (CFB) using oxygen storage materials as oxygen carrier was reported. First, oxygen in the air was chemically fixed and converted to lattice oxygen of oxygen storage materials over regenerator, and then methane was selectively oxidized to synthesis gas with lattice oxygen of oxygen storage materials over riser reactor. The results from simulation reaction of CFB by sequential redox reaction on a fixed bed reactor using lanthanum-based perovskite LaFeO3 and La0.8Sr0.2Fe0.9Co0.1O3 oxides prepared by sol-gel, suggested that the depleted oxygen species could be regenerated, and methane could be oxidized to synthesis gas by lattice oxygen with high selectivity. The partial oxidation of methane to synthesis gas over CFB using lattice oxygen of the oxygen storage materials instead of gaseous oxygen should be possibly applicable.

  3. Simulation studies of diesel engine performance with oxygen enriched air and water emulsified fuels

    Energy Technology Data Exchange (ETDEWEB)

    Assanis, D.N.; Baker, D. (Illinois Univ., Urbana, IL (USA)); Sekar, R.R.; Siambekos, C.T.; Cole, R.L.; Marciniak, T.J. (Argonne National Lab., IL (USA))

    1990-01-01

    A computer simulation code of a turbocharged, turbocompound diesel engine was modified to study the effects of using oxygen-enriched combustion air and water-emulsified diesel fuels. Oxygen levels of 21 percent to 40 percent by volume in the combustion air were studied. Water content in the fuel was varied from 0 percent to 50 percent mass. Simulation studies and a review and analysis of previous work in this area led to the following conclusions about expected engine performance and emissions: the power density of the engine is significantly increased by oxygen enrichment. Ignition delay and particulate emissions are reduced. Combustion temperatures and No{sub x} emissions are increased with oxygen enrichment but could be brought back to the base levels by introducing water in the fuel. The peak cylinder pressure which increases with the power output level might result in mechanical problems with engine components. Oxygen enrichment also provides an opportunity to use cheaper fuel such as No. 6 diesel fuel. Overall, the adverse effects of oxygen enrichment could be countered by the addition of water and it appears that an optimum combination of water content, oxygen level, and base diesel fuel quality may exist. This could yield improved performance and emissions characteristics compared to a state-of-the-art diesel engine. 9 refs., 8 figs.

  4. Methods for separating oxygen from oxygen-containing gases

    Science.gov (United States)

    Mackay, Richard; Schwartz, Michael; Sammells, Anthony F.

    2000-01-01

    This invention provides mixed conducting metal oxides particularly useful for the manufacture of catalytic membranes for gas-phase oxygen separation processes. The materials of this invention have the general formula: A.sub.x A'.sub.x A".sub.2-(x+x') B.sub.y B'.sub.y B".sub.2-(y+y') O.sub.5+z ; where x and x' are greater than 0; y and y' are greater than 0; x+x' is less than or equal to 2; y+y' is less than or equal to 2; z is a number that makes the metal oxide charge neutral; A is an element selected from the f block lanthanide elements; A' is an element selected from Be, Mg, Ca, Sr, Ba and Ra; A" is an element selected from the f block lanthanides or Be, Mg, Ca, Sr, Ba and Ra; B is an element selected from the group consisting of Al, Ga, In or mixtures thereof; and B' and B" are different elements and are independently selected from the group of elements Mg or the d-block transition elements. The invention also provides methods for oxygen separation and oxygen enrichment of oxygen deficient gases which employ mixed conducting metal oxides of the above formula. Examples of the materials used for the preparation of the membrane include A.sub.x Sr.sub.x' B.sub.y Fe.sub.y' Co.sub.2-(y+y') O.sub.5+z, where x is about 0.3 to about 0.5, x' is about 1.5 to about 1.7, y is 0.6, y' is between about 1.0 and 1.4 and B is Ga or Al.

  5. Manipulation of environmental oxygen modifies reactive oxygen and nitrogen species generation during myogenesis

    Directory of Open Access Journals (Sweden)

    Rachel McCormick

    2016-08-01

    Data demonstrate that satellite cell proliferation increased when cells were grown in 6% O2 compared with 20% O2. Myoblasts grown in 20% O2 showed an increase in DCF fluorescence and DHE oxidation compared with myoblasts grown at 6% O2. Myotubes grown in 20% O2 also showed an increase in DCF and DAF-FM fluorescence and DHE oxidation compared with myotubes grown in 6% O2. The catalase and MnSOD contents were also increased in myoblasts and myotubes that were maintained in 20% O2 compared with myoblasts and myotubes grown in 6% O2. These data indicate that intracellular RONS activities in myoblasts and myotubes at rest are influenced by changes in environmental oxygen concentration and that the increased ROS may influence myogenesis in a negative manner.

  6. Thenar oxygen saturation and invasive oxygen delivery measurements in critically ill patients in early septic shock.

    Science.gov (United States)

    Mesquida, Jaume; Gruartmoner, Guillem; Martínez, Maria Luisa; Masip, Jordi; Sabatier, Caroline; Espinal, Cristina; Artigas, Antonio; Baigorri, Francisco

    2011-05-01

    This prospective study was aimed to test the hypothesis that tissue hemoglobin oxygen saturation (StO₂) measured noninvasively using near-infrared spectroscopy is a reliable indicator of global oxygen delivery (DO₂) measured invasively using a pulmonary artery catheter (PAC) in patients with septic shock. The study setting was a 26-bed medical-surgical intensive care unit at a university hospital. Subjects were adult patients in septic shock who required PAC hemodynamic monitoring for resuscitation. Interventions included transient ischemic challenge on the forearm. After blood pressure normalization, hemodynamic and oximetric PAC variables and, simultaneously, steady-state StO₂ and its changes from ischemic challenge (deoxygenation and reoxygenation rates) were measured. Fifteen patients were studied. All the patients had a mean arterial pressure above 65 mmHg. The DO₂ index (iDO₂) range in the studied population was 215 to 674 mL O₂/min per m. The mean mixed venous oxygen saturation value was 61% ± 10%, mean cardiac index was 3.4 ± 0.9 L/min per m, and blood lactate level was 4.6 ± 2.7 mmol/L. Steady-state StO₂ significantly correlated with iDO₂, arterial and venous O₂ content, and O₂ extraction ratio. A StO₂ cutoff value of 75% predicted iDO₂ below 450, with a sensitivity of 0.9 and a specificity of 0.9. In patients in septic shock and normalized MAP, low StO₂ reflects extremely low iDO₂. Steady-state StO₂ does not correlate with moderately low iDO₂, indicating poor sensitivity of StO₂ to rule out hypoperfusion.

  7. A review of oxygen removal from oxygen-bearing coal-mine methane.

    Science.gov (United States)

    Zhao, Peiyu; Zhang, Guojie; Sun, Yinghui; Xu, Ying

    2017-06-01

    In this article, a comparison will be made concerning the advantages and disadvantages of five kinds of coal mine methane (CMM) deoxygenation method, including pressure swing adsorption, combustion, membrane separation, non-metallic reduction, and cryogenic distillation. Pressure swing adsorption has a wide range of application and strong production capacity. To achieve this goal, adsorbent must have high selectivity, adsorption capacity, and adequate adsorption/desorption kinetics, remain stable after several adsorption/desorption cycles, and possess good thermal and mechanical stabilities. Catalytic combustion deoxygenation is a high-temperature exothermic redox chemical reaction, which releases large amounts of thermal energy. So, the stable and accurate control of the temperature is not easy. Meanwhile partial methane is lost. The key of catalytic combustion deoxygenation lies in the development of high-efficiency catalyst. Membrane separation has advantages of high separation efficiency and low energy consumption. However, there are many obstacles, including higher costs. Membrane materials have the requirements of both high permeability and high selectivity. The development of new membrane materials is a key for membrane separation. Cryogenic distillation has many excellence advantages, such as high purity production and high recovery. However, the energy consumption increases with decreasing CH4 concentrations in feed gas. Moreover, there are many types of operational security problems. And that several kinds of deoxygenation techniques mentioned above have an economic value just for oxygen-bearing CMM with methane content above 30%. Moreover, all the above methods are not applicable to deoxygenation of low concentration CMM. Non-metallic reduction method cannot only realize cyclic utilization of deoxidizer but also have no impurity gases generation. It also has a relatively low cost and low loss rate of methane, and the oxygen is removed thoroughly. In

  8. Diurnal fluctuations in root oxygen release rate and dissolved oxygen budget in wetland mesocosm

    OpenAIRE

    Dong, C.; Zhu, W; Zhao, Y. Q.; Gao, M

    2011-01-01

    To assess the role of plants for oxygen offering in constructed wetlands, this study experimentally evaluated the amount of root oxygen release rate using mass balance method. The mass balance calculation is based on the following components: respiratory oxygen consumption of the roots; oxygen required for degradation of the organic matters; oxygen required for nitrification; and the amount of dissolved oxygen in the influent, effluent and substrate water. Experimental results have demonstrat...

  9. Oxygen permeation through perovskitic membranes: The influence of steam in the sweep on the permeation performance

    Directory of Open Access Journals (Sweden)

    Michael Müller

    2016-08-01

    Full Text Available Experimental approaches are employed for the understanding of oxygen permeation through membranes. For the experiments, different oxygen partial pressures are applied to both sides of a BSCF5582 membrane, using synthetic air as feed and vacuum or steam/argon as sweep gas. Beside the partial pressure gradient, the permeation rate depends on the temperature and the membrane thickness. Sufficient permeation rates can be achieved by sweeping the membrane with water vapor (steam instead of a noble gas, which is optimized by ascending water content in the sweep gas. The influence of the steam content on the permeation performance as well as microstructural changes are demonstrated.

  10. Explicit Content Image Detection

    Directory of Open Access Journals (Sweden)

    Jorge Alberto Marcial Basilio

    2011-02-01

    Full Text Available This paper proposes a system gives for explicit content image detection based on Computer VisionAlgorithms, pattern recognition and FTK software Explicit Image Detection. In the first stage, HSV colormodel is used for the input images for the purpose of discriminating elements that are not human skinimages. Then the image is filtered using skin detection. The output image only contains the areas of whichit is composed. The results show a comparison between the proposed system and the company softwareAccess Data called Forensic Toolkit 3.1 Explicit Image Detection isperformed.

  11. Explicit Content Image Detection

    Directory of Open Access Journals (Sweden)

    Jorge Alberto Marcial Basilio

    2010-12-01

    Full Text Available This paper proposes a system gives for explicit content image detection based on Computer Vision Algorithms, pattern recognition and FTK software Explicit Image Detection. In the first stage, HSV color model is used for the input images for the purpose of discriminating elements that are not human skin images. Then the image is filtered using skin detection. The output image only contains the areas of which it is composed. The results show a comparison between the proposed system and the company software Access Data called Forensic Toolkit 3.1 Explicit Image Detection isperformed.

  12. Personalized professional content recommendation

    Science.gov (United States)

    Xu, Songhua

    2015-10-27

    A personalized content recommendation system includes a client interface configured to automatically monitor a user's information data stream transmitted on the Internet. A hybrid contextual behavioral and collaborative personal interest inference engine resident to a non-transient media generates automatic predictions about the interests of individual users of the system. A database server retains the user's personal interest profile based on a plurality of monitored information. The system also includes a server programmed to filter items in an incoming information stream with the personal interest profile and is further programmed to identify only those items of the incoming information stream that substantially match the personal interest profile.

  13. Solid-Sampling Electrothermal Vaporization Inductively Coupled Plasma Optical Emission Spectrometry for Direct Determination of Total Oxygen in Coal.

    Science.gov (United States)

    Vogt, Thomas; Bauer, Daniela; Nennstiel, David; Otto, Matthias

    2015-10-20

    A new analytical method for direct determination of total oxygen contents in eight coal samples of the Argonne Premium Coal (APC) series and in the NIST SRM 1632d is presented. The development of a suitable calibration procedure, optimization of measurement conditions, and the application of a tailored data processing for handling of plasma effects and high blanks enable the quantification of oxygen simultaneously with other trace, minor, or major elements in whole coal samples by means of electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV-ICP OES). For comparison, the oxygen contents were determined by a direct oxygen analyzer. The obtained oxygen values of the APC and the reference material NIST SRM 1632d were compared to data in the literature. The precision of the ETV-ICP OES was within ±3.5%, and the recovery better than 92%. With this good accuracy, the developed direct solid sampling method ETV-ICP OES is well suited for the fast determination of oxygen in coals, varying in rank from lignite to semianthracite, in a content range of about 100 ppm up to 27% using 1.5 mg sample weight. This direct analysis method represents an accurate, advantageous alternative to currently used methods for estimation of total oxygen contents in coals.

  14. Decreased oxygen permeability of EVOH through molecular interactions

    Directory of Open Access Journals (Sweden)

    Zs. Peter

    2014-10-01

    Full Text Available Poly(ethylene-co-vinyl alcohol of 48 mol% ethylene content was modified with N,N'-bis(2,2,6,6-tetramethyl-4-piperidyl-isophthalamide (Nylostab SEED to decrease the oxygen permeability of the polymer. The additive was added in a wide concentration range from 0 to 10 wt%. The structure and properties of the polymer were characterized with various methods including differential scanning calorimetry, X-ray diffraction, mechanical testing, optical measurements and oxygen permeation. Interactions were estimated by molecular modeling and infrared spectroscopy. The results showed that oxygen permeation decreased considerably when the additive was added at less than 2.0 wt% concentration. The decrease resulted from the interaction of the hydroxyl groups of the polymer and the amide groups of the additive. The dissolution of the additive in the polymer led to decreased crystallinity, but also to decreased mobility of amorphous molecules. Stiffness and strength, but also deformability increased as a result. Above 2 wt% the additive forms a separate phase leading to the deterioration of properties. The success of the approach represents a novel way to control oxygen permeation in EVOH and in other polymers with similar functional groups capable of strong interactions.

  15. Facile synthesis of a ratiometric oxygen nanosensor for cellular imaging.

    Science.gov (United States)

    Lu, Sisi; Xu, Wei; Zhang, Jinliang; Chen, Yiying; Xie, Lei; Yao, Qiuhong; Jiang, Yaqi; Wang, Yiru; Chen, Xi

    2016-12-15

    A new type of cell-penetrating ratiometric fluorescence oxygen sensing nanoparticle was prepared through a facile co-precipitation method. Amphiphilic polymer poly (styrene-co-maleic anhydride) (PSMA) was firstly cooperated with polystyrene (PS) to envelop the highly photostable phosphorescent oxygen indicator, platinum(II)-tetrakis(pentafluorophenyl)porphyrin (PtTFPP, emission at 648nm), and the reference fluorophore, poly(9, 9-dioctylfluorene) (PFO, emission at 440nm ), via hydrophobic interaction in aqueous solution. To improve the sensor biocompatibility, the biomacromolecule poly-l-lysine (PLL) was selected to act as a shell via electrostatic forces. The as-prepared PtTFPP doped core-shell nanoparticles (called PPMA/PLL NPs) exhibited an excellent ratiometric luminescence response to O2 content with high quenching efficiency and full reversibility in the oxygen sensing. More importantly, these oxygen nanosensors passed across the cell membrane after co-incubation without external force. Labeled cells exhibited high brightness in the matching blue and red channels of a digital camera. And most nanosensors were found locating in cytoplasm rather than being trapped in endosomes.

  16. Improvement of oxygen diffusion characteristic in gas diffusion layer with planar-distributed wettability for polymer electrolyte fuel cell

    Science.gov (United States)

    Koresawa, Ryo; Utaka, Yoshio

    2014-12-01

    Mass transfer characteristics of gas diffusion layer (GDL) are closely related to performance of polymer electrolyte fuel cells. Therefore, it is necessary to clarify the characteristics of water distribution relating to the microscopic conformation and oxygen diffusivity of GDL. A hybrid type carbon paper GDL with planar-distributed wettability is investigated for control of liquid water movement and distribution due to hydrophobic to hydrophilic areas that provide wettability differences in GDL and to achieve enhancement of both oxygen diffusion and moisture retention. Hybrid GDLs with different PTFE content were fabricated in an attempt to improve the oxygen diffusion characteristics. The effects of different PTFE contents on the oxygen diffusivity and water distribution were simultaneously measured and observed using galvanic cell oxygen absorber and X-ray radiography. The PTFE distribution was observed using scanning electron microscopy. The formation of oxygen diffusion paths was confirmed by X-ray radiography, where voids in the hybrid GDL were first formed in the hydrophobic regions and then spread to the untreated wetting region. Thus, the formation of oxygen diffusion paths enhanced the oxygen diffusion. In addition, the effects of local PTFE content in the hydrophobic region and the optimal amount of PTFE for hybrid GDL were elucidated.

  17. Influence of propane content on thermal shock property of TiB2-25Ni coating sprayed by high velocity oxygen fuel%丙烷流量对超音速火焰喷涂TiB2-25Ni涂层抗热震性能的影响

    Institute of Scientific and Technical Information of China (English)

    陈枭; 王洪涛; 纪岗昌; 白小波; 张琳

    2016-01-01

    Different coatings were prepared on Q235 steel substrate surface used mechanical milling TiB2-25Ni particles as raw materials by high velocity oxygen fuel (HVOF) under three kinds of propane flows(30,36 and 42 L/min),the thermal shock property of the coatings at 600 ℃ (50 cycles,100 cycles and 150 cycles) and 800 ℃ was tested.The surface and cross-sectional morphology of the coatings after thermal shock test were studied by scanning electron microscopy (SEM) to analyze the crack generation and propagation,and the composition transformation of the coatings was analyzed by X-ray diffraction analysis (XRD).The results show that with increasing the thermal shock cycles,the propagating cracks of the three kinds of the coatings are worse at 600 ℃,and there are longitudinal and transverse cracks appeare in the coatings,especially the coating with propane flow rate of 36 L/min is the worst among the three coatings.The thermal shock cycles are obviously decreased and the coatings are invalid faster under 800 ℃ conditions,meanwhile,there are a network of cracks appear on the surface of the coatings,and the cracks propagate into the interface of the coating and substrate,it can lead to the substrate corroded by the corrosion medium (i.e.water,air) to form metallic oxide.By investigating the phase composition of the three coatings after thermal shock,the main composition of the coatings is TiB2 and Ni,and the metallic oxides increase after thermal shock test.%采用超音速火焰喷涂技术(HVOF)在3种丙烷流量(30,36和42 L/min)下将机械球磨后的TiB2-25 Ni颗粒沉积在Q235钢表面上获得不同涂层,将涂层在600℃(50次、100次、150次)和800℃工况下进行热震试验,研究涂层的抗热震性能.采用扫描电镜(SEM)表征热震后涂层的表面和截面形貌以分析热震后的裂纹产生和扩展情况,通过X射线衍射技术(XRD)分析热震后涂层的物相演变规律.研究结果发现,3种涂层在600℃热震条件下随

  18. Guancydine, a new hypotensive agent with complex action.

    Science.gov (United States)

    Hărăgus, S T; Uza, G; Duncea, C

    1977-01-01

    Guancydine (1-cyano-3-tert-amylguanidine) lowered within normal limits the tensional values in an interval of four hours after its administration in eight out of nine hypertensive patients under experiment. The hypotensive effect of a single oral dose of 500-750 mg persists for about 6-7 hours after its administration. Guancydine does not impair the vasopressor response to angiotensin II but reduces the action of this peptide on the excretion of water, Na, K and Ca through urine. The hypotensive effect of Guancydine is associated with a decrease of platelet adhesiveness and an activation of fibrinolysis. In view of this fact, Guancydine might play a role in the prophylaxis of complications of arterial hypertension - atherosclerosis and trombosis. The increase of venous blood oxygenation after Guancydine could be attributed to the opening of arterio-venous shunts or to the reduction of tissular extraction of oxygen. Guancydine does not seem to be toxic. It produced, in some patients, slight headache and orthostatic hypotension, especially during the first hours after administration.

  19. Evaluation of garlic cultivars for polyphenolic content and antioxidant properties.

    Directory of Open Access Journals (Sweden)

    Shuxia Chen

    Full Text Available Two phenolic compound parameters (total phenolic and flavonoid contents and 5 antioxidant parameters (DPPH [2, 2-diphenyl-1-picrylhydrazyl] radical scavenging activity, HRSC (hydroxyl radical scavenging capacity, FRAP (ferric ion reducing antioxidant power, CUPRAC (cupric ion reducing antioxidant capacity, and MCA (metal chelating activity were measured in bulbs and bolts of 43 garlic cultivars. The bulbs of cultivar '74-x' had the highest phenolic content (total phenolic, flavonoids and the strongest antioxidant capacity (DPPH, FRAP, and CUPRAC, followed by bulbs of cultivar 'Hanzhong purple'; the bulbs of cultivar 'Gailiang' had the lowest phenolic content and antioxidant capacity (FRAP, CUPRAC, MCA. The bolts of 'Hanzhong purple' also had higher phenolic content. Principal components analysis (PCA separated the cultivars into 3 groups according to phenolic and flavonoid contents and strength of antioxidant activity. The first group had higher HRSC, FRAP, and flavonoid content; the second group had higher total phenolic content and MCA; some cultivars in the third group had higher HRSC and FRAP. All 8 test garlic bulb extracts successfully prevented Human Vascular Endothelial Cell death and significantly prevented reactive-oxygen species (ROS formation in oxidative stress model, in which cultivar '74-x' had highest protection capability, following by cultivar 'Hanzhong purple', and the bulbs of cultivar 'No. 105 from Korea' had the lower protection capability against cell death and ROS formation. The protection capability in vivo of these garlic cultivars was consistent with their phenolic content and antioxidant capacity.

  20. Evaluation of garlic cultivars for polyphenolic content and antioxidant properties.

    Science.gov (United States)

    Chen, Shuxia; Shen, Xiaoqing; Cheng, Siqiong; Li, Panpan; Du, Junna; Chang, Yanxia; Meng, Huanwen

    2013-01-01

    Two phenolic compound parameters (total phenolic and flavonoid contents) and 5 antioxidant parameters (DPPH [2, 2-diphenyl-1-picrylhydrazyl] radical scavenging activity, HRSC (hydroxyl radical scavenging capacity), FRAP (ferric ion reducing antioxidant power), CUPRAC (cupric ion reducing antioxidant capacity), and MCA (metal chelating activity) were measured in bulbs and bolts of 43 garlic cultivars. The bulbs of cultivar '74-x' had the highest phenolic content (total phenolic, flavonoids) and the strongest antioxidant capacity (DPPH, FRAP, and CUPRAC), followed by bulbs of cultivar 'Hanzhong purple'; the bulbs of cultivar 'Gailiang' had the lowest phenolic content and antioxidant capacity (FRAP, CUPRAC, MCA). The bolts of 'Hanzhong purple' also had higher phenolic content. Principal components analysis (PCA) separated the cultivars into 3 groups according to phenolic and flavonoid contents and strength of antioxidant activity. The first group had higher HRSC, FRAP, and flavonoid content; the second group had higher total phenolic content and MCA; some cultivars in the third group had higher HRSC and FRAP. All 8 test garlic bulb extracts successfully prevented Human Vascular Endothelial Cell death and significantly prevented reactive-oxygen species (ROS) formation in oxidative stress model, in which cultivar '74-x' had highest protection capability, following by cultivar 'Hanzhong purple', and the bulbs of cultivar 'No. 105 from Korea' had the lower protection capability against cell death and ROS formation. The protection capability in vivo of these garlic cultivars was consistent with their phenolic content and antioxidant capacity.