WorldWideScience

Sample records for arterio-venous oxygen content

  1. Fanconi anaemia with bilateral diffuse pulmonary arterio venous fistulae: a case report

    Directory of Open Access Journals (Sweden)

    Samarakoon Lasitha

    2012-03-01

    Full Text Available Abstract Background We report a patient with cytogenetically confirmed Fanconi anaemia with associated diffuse bilateral pulmonary arterio-venous fistulae. This is only the second reported case of diffuse pulmonary arterio-venous fistulae with Fanconi anaemia. Case Presentation A 16 year old Sri Lankan boy, with a cytogenetically confirmed Fanconi anaemia was admitted to University Medical Unit, National Hospital of Sri Lanka for further assessment and treatment. Both central and peripheral cyanosis plus clubbing were noted on examination. The peripheral saturation was persistently low on room air and did not improve with supplementary Oxygen. Contrast echocardiography failed to demonstrate an intra cardiac shunt but showed early crossover of contrast, suggesting the possibility of pulmonary arterio-venous fistulae. Computed tomography pulmonary angiogram was inconclusive. Subsequent right heart catheterisation revealed bilateral diffuse arterio-venous fistulae not amenable for device closure or surgical intervention. Conclusion To our knowledge, this is the second reported patient with diffuse pulmonary arterio-venous fistulae associated with Fanconi anaemia. We report this case to create awareness among clinicians regarding this elusive association. We recommend screening patients with Fanconi anaemia using contrast echocardiography at the time of assessment with transthoracic echocardiogram. Though universal screening may be impossible given the cost constraints, such screening should at least be performed in patients with clinical evidence of desaturation or when a therapeutic option such as haematopoietic stem cell transplantation is considered. Treatment of pulmonary arteriovenous fistulae would improve patient outcome as desaturation by shunting worsens the anaemic symptoms by reducing the oxygen carrying capacity of blood.

  2. Intracranial dural arterio-venous fistula presenting with progressive myelopathy.

    LENUS (Irish Health Repository)

    Ogbonnaya, Ebere Sunny

    2011-01-01

    Spinal dural arterio-venous fistula (DAVF) is rare and usually involves the thoracic segments. The classical presentation is a slowly progressive ataxia. Clinical presentation of intracranial DAVF depends on the site of the DAVF, as well as the vessels involved. Patients may present with pulsatile tinnitus, occipital bruit, headache, dementia, visual impairment as well as neurological deterioration distant from the DAVF as a result of venous hypertension and cortical haemorrhage. The authors present a rare case of progressive myelopathy secondary to an intracranial DAVF.

  3. Pulmonary arterio-venous micro fistulae - Diagnostic

    International Nuclear Information System (INIS)

    Ebram, J.C.

    1989-01-01

    Four patients with pulmonary arterio-venous micro-fistulae - of which two were male (50%) - the ages varying from 10 to 43 (X sup(∼) = 22,7), were studied at the Cardiology Centre of the 6th Ward of Santa Casa da Misericordia Hospital in Rio de Janeiro. They were all basically suffering from Manson's Schistosomiasis, the hepato-splenic form in 3 cases (75%) and the Rendu Osler Weber disease with juvenile cirrhosis in 1 case (25%). All four of them had portal hypertension. The individual cases were clinically evaluate with X-rays, scintillographic and hemodynamic tests. (author)

  4. Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion. Nonlinear decay of adult red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van; Wijngaard, Jeroen P H M van den [Laser Centre and Department of Obstetrics, Academic Medical Centre, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Pasman, Suzanne A; Vandenbussche, Frank P H A [Division of Fetal Medicine, Department of Obstetrics, Leiden University Medical Centre, Leiden (Netherlands); Lopriore, Enrico [Division of Neonatology, Department of Pediatrics, Leiden University Medical Centre, Leiden (Netherlands)], E-mail: m.j.vangemert@amc.uva.nl

    2008-07-07

    Recently, we derived equations relating the flow of adult red blood cells through a placental arterio-venous anastomosis with intra-uterine and post-natal measured adult hemoglobin concentrations. In this letter, we re-derived the equations, now including a more realistic nonlinear decay of adult red blood cells, and re-evaluated the measurement accuracy of the arterio-venous flow and the lifetime of the red blood cells. (letter to the editor)

  5. Monitoring arterio-venous differences of glucose and lactate in the anesthetized rat with or without brain damage with ultrafiltration and biosensor technology

    NARCIS (Netherlands)

    Leegsma-Vogt, G; Venema, K; Postema, F; Korf, J

    2001-01-01

    Continuous monitoring of arterio-venous glucose and lactate differences may serve as a diagnostic tool to assess normal brain function and brain pathology. We describe a method and some results obtained with arterio-venous measurements of glucose and lactate in the blood of the

  6. Cerebral arterio-venous malformations at Edgardo Rebagliati Martins Nacional Hospital

    OpenAIRE

    Rabanal, Jorge

    2014-01-01

    A review of 50 cases with cerebral arterio.venous malformations (AVM) treated since Junly 1988 through December 1992 in the Neurosurgery Service from Edgardo Rebagliati Martins National Hospital was done. Clinical records, surgical techniques and pre- and post-operative studies were evaluted by retrospective analysis. The more important results were the frecuency of presentations in male patients from the coast, the clinical onset with intracraneal hemorrhage, the operative technique of drain...

  7. Quantitative determination of peripheral arterio-venous shunts by means of radioactively labelled microspheres

    International Nuclear Information System (INIS)

    Friese, K.H.

    1981-01-01

    In the present work a nuclear method of quantitative measurement of peripheral arterio-venous shunts with a whole-body scanner is standardized. This method, developed at the beginning of the 70s at Tuebingen, stands out in contrast with earlier measuring methods by the application of the theory of quantitative scintiscanning. This means that the scintigram obtained after injection of sup(99m)technetium-labelled human albumin microspheres into an artery before the shunt is corrected for the quantitative shunt calculation by several factors using a computer, to avoid systematic mistakes. For the standardization of the method, 182 scintigrams were taken during model experiments and experiments on animals and human beings. This method, having a deviation of 10% at most, is excellently suited for the quantitative determination of peripheral arterio-venous shunts. Already for a pulmonary activity of 3% a peripheral shunt is proved with 97.5% probability. (orig./MG) [de

  8. A Rare Case of Jejunal Arterio-Venous Fistula: Treatment with Superselective Catheter Embolization with a Tracker-18 Catheter and Microcoils

    International Nuclear Information System (INIS)

    Sonnenschein, Martin J.; Anderson, Suzanne E.; Lourens, Steven; Triller, Juergen

    2004-01-01

    Arterio-venous fistulas may develop spontaneously, following trauma or infection, or be iatrogenic in nature. We present a rare case of a jejunal arterio- venous fistula in a 35-year-old man with a history of pancreatic head resection that had been performed two years previously because of chronic pancreatitis. The patient was admitted with acute upper abdominal pain, vomiting and an abdominal machinery-type bruit. The diagnosis of a jejunal arterio-venous fistula was established by MR imaging. Transfemoral angiography was performed to assess the possibility of catheter embolization. The angiographic study revealed a small aneurysm of the third jejunal artery, abnormal early filling of dilated jejunal veins and marked filling of the slightly dilated portal vein (13-14 mm). We considered the presence of segmental portal hypertension. The patient was treated with coil embolization in the same angiographic session. This case report demonstrates the importance of auscultation of the abdomen in the initial clinical examination. MR imaging and color Doppler ultrasound are excellent noninvasive tools in establishing the diagnosis. The role of interventional radiological techniques in the treatment of early portal hypertension secondary to jejunal arterio-venous fistula is discussed at a time when this condition is still asymptomatic. A review of the current literature is included

  9. LETTER TO THE EDITOR: Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion. Nonlinear decay of adult red blood cells

    Science.gov (United States)

    van Gemert, Martin J. C.; Pasman, Suzanne A.; van den Wijngaard, Jeroen P. H. M.; Lopriore, Enrico; Vandenbussche, Frank P. H. A.

    2008-07-01

    Recently, we derived equations relating the flow of adult red blood cells through a placental arterio-venous anastomosis with intra-uterine and post-natal measured adult hemoglobin concentrations. In this letter, we re-derived the equations, now including a more realistic nonlinear decay of adult red blood cells, and re-evaluated the measurement accuracy of the arterio-venous flow and the lifetime of the red blood cells.

  10. Consensus Document of the International Union of Angiology (IUA)-2013. Current concept on the management of arterio-venous management

    NARCIS (Netherlands)

    Lee, B.B.; Baumgartner, I.; Berlien, H.P.; Bianchini, G.; Burrows, P.; Do, Y.S.; Ivancev, K.; Schultze Kool, L.J.; Laredo, J.; Loose, D.A.; Lopez-Gutierrez, J.C.; Mattassi, R.; Parsi, K.; Rimon, U.; Rosenblatt, M.; Shortell, C.; Simkin, R.; Stillo, F.; Villavicencio, L.; Yakes, W.

    2013-01-01

    Arterio-venous malformations (AVMs) are congenital vascular malformations (CVMs) that result from birth defects involving the vessels of both arterial and venous origins, resulting in direct communications between the different size vessels or a meshwork of primitive reticular networks of dysplastic

  11. Occupational therapy for patients with an arterio-venous fistula

    Directory of Open Access Journals (Sweden)

    Iustinian BENGULESCU

    2017-03-01

    Full Text Available End stage renal disease (ESRD represents a chronic medical condition that has become a public health problem and requires substantial funding. The number of patients with ESRD is rapidly increasing. From the moment that ESRD is diagnosed, the natural evolution of this pathology is towards mandatory dialysis, in absence of a renal transplant procedure. In order to perform hemodialysis, a vascular access site must be created and maintained functional. A proper vascular access site allows an adequate blood flow through the dialysis machine, in order to obtain the required results. The arterio-venous fistula represents the number one recommended vascular access site procedure. Establishing and maintaining a vascular access represents one of the biggest problems in hemodialysis. The arterio-venous fistula thus becomes the patient’s lifeline. Maintaining a good quality vascular access site is a demanding process and requires cooperation between both the patient and the health care providers. For ESRD patients there is a constant concern regarding the patency of their vascular access. The aim of this paper is to present the postoperative measures that ESRD patients should provide in order to preserve their vascular access. Also, we want to present the main signs of an early complication that patients should recognize and therefore immediately present themselves to the physician. By establishing this type of cooperation and trust between the patient and the medical staff we will be able to reduce the number of surgical procedures required for the creation and maintenance of the vascular access. Our final thought remains that a well-informed patient has better chances of prolonging his “lifeline”.

  12. Suppressing unsteady flow in arterio-venous fistulae

    Science.gov (United States)

    Grechy, L.; Iori, F.; Corbett, R. W.; Shurey, S.; Gedroyc, W.; Duncan, N.; Caro, C. G.; Vincent, P. E.

    2017-10-01

    Arterio-Venous Fistulae (AVF) are regarded as the "gold standard" method of vascular access for patients with end-stage renal disease who require haemodialysis. However, a large proportion of AVF do not mature, and hence fail, as a result of various pathologies such as Intimal Hyperplasia (IH). Unphysiological flow patterns, including high-frequency flow unsteadiness, associated with the unnatural and often complex geometries of AVF are believed to be implicated in the development of IH. In the present study, we employ a Mesh Adaptive Direct Search optimisation framework, computational fluid dynamics simulations, and a new cost function to design a novel non-planar AVF configuration that can suppress high-frequency unsteady flow. A prototype device for holding an AVF in the optimal configuration is then fabricated, and proof-of-concept is demonstrated in a porcine model. Results constitute the first use of numerical optimisation to design a device for suppressing potentially pathological high-frequency flow unsteadiness in AVF.

  13. Portal Hypertension Secondary to Spontaneous Arterio-Portal Venous Fistulas: Transcatheter Arterial Embolization with n-Butyl Cyanoacrylate and Microcoils

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Nakamura, Toshiyuki; Nishimura, Tsunehiko

    2000-01-01

    We report a 73-year-old man with recurrent variceal bleeding due to portal hypertension caused by multiple intrahepatic arterio-portal venous fistulas, which were successfully occluded by embolization with n-butyl cyanoacrylate and micro-coils

  14. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  15. Differential kinetics of response and toxicity using stereotactic radiation and interventional radiological coiling for pulmonary arterio-venous shunting from metastatic leiomyosarcoma

    International Nuclear Information System (INIS)

    Wong, Annie Ngai Man; Siva, Shankar; Chin, Kwang; Manser, Renee; Antippa, Phillip; Dowling, Richard; Mileshkin, Linda Rose

    2015-01-01

    Case report demonstrating the differential kinetics of response and toxicity using stereotactic radiation and interventional radiological coiling for pulmonary arterio-venous shunting from leiomyosarcoma pulmonary metastases.

  16. Effective flow performances and dialysis doses delivered with permanent catheters: a 24-month comparative study of permanent catheters versus arterio-venous vascular accesses.

    Science.gov (United States)

    Canaud, Bernard; Leray-Moragues, Hélène; Kerkeni, Nadia; Bosc, Jean-Yves; Martin, Katja

    2002-07-01

    Permanent venous catheters have emerged as a long-term vascular access option for renal replacement therapy in end-stage renal disease patients. The design and venous location of catheter devices bear intrinsic flow limitations that may negatively affect the adequacy of dialysis and the patient outcome. There is limited data comparing the long-term dialysis adequacy delivered with permanent catheters vs arterio-venous vascular accesses (AVA). To explore this problem, we conducted a prospective 24-month trial comparing the flow performances and dialysis dose (Kt/Vdp) deliveries of both access options in a group of 42 haemodialysis patients during two study phases. During the first 12 months the patients completed a treatment period by means of permanent dual silicone catheters (DualKT). Then they were transferred to an AVA (40 native arterio-venous fistulas and two PTFE grafts) and monitored for an additional 12-month period. Assessments of flow adequacy and dialysis quantification were performed monthly. Dialysis adequacy was achieved in all cases. No patient had to be transferred prematurely to the AVA because of catheter failure. Three catheters had to be replaced due to bacteraemia in three patients. The mean effective blood flow rates achieved were 316+/-3.5 ml/min and 340+/-3.3 ml/min with DualKT and AVA, respectively, for a pre-set machine blood flow of 348+/-2.2 ml/min. Recirculation rates evaluated with the 'slow blood flow' method were 8.6+/-0.6 and 12.1+/-0.8% for DualKT and AVA using mean values of the solute markers urea and creatinine. Due to the possibility of a comparison veno-venous vs arterio-venous blood circulation, a corrected arterio-venous access recirculation could be derived from the difference between the two, which was around 3%. The blood flow resistance of the DualKT was slightly higher than with AVA as indicated by venous pressure differences. Kt/Vdp delivered was 1.37+/-0.02 and 1.45+/-0.02 with DualKT and AVA access respectively. The

  17. Arterio-venous malformations in childhood: clinical presentation, results after operative treatment and long-term follow-up.

    Science.gov (United States)

    Kahl, W; Kessel, G; Schwarz, M; Voth, D

    1989-01-01

    In a series of 182 arterio-venous malformations (AVM) recently published we found 33 children aged 1 to 16 years. In 28 cases, the admitting condition was hemorrhage. For 31 AVMs total excision was possible. We observed one postoperative death accounting for a mortality of 3%. All children but two were followed-up by personal examination. Two were not able to work due to severe neurological deficits and seven had not been able to get into their intended occupation.

  18. Arterio-venous anastomoses in isolated, perfused rat lungs.

    Science.gov (United States)

    Conhaim, Robert L; Segal, Gilad S; Watson, Kal E

    2016-11-01

    Several studies have suggested that large-diameter (>25 μm) arterio-venous shunt pathways exist in the lungs of rats, dogs, and humans. We investigated the nature of these pathways by infusing specific-diameter fluorescent latex particles (4, 7, 15, 30, or 50 μm) into isolated, ventilated rat lungs perfused at constant pressure. All lungs received the same mass of latex (5 mg), which resulted in infused particle numbers that ranged from 1.7 × 10 7 4 μm particles to 7.5 × 10 4 50 μm particles. Particles were infused over 2 min. We used a flow cytometer to count particle appearances in venous effluent samples collected every 0.5 min for 12 min from the start of particle infusion. Cumulative percentages of infused particles that appeared in the samples averaged 3.17 ± 2.46% for 4 μm diameter particles, but ranged from 0.01% to 0.17% for larger particles. Appearances of 4 μm particles followed a rapid upslope beginning at 30 sec followed by a more gradual downslope that lasted for up to 12 min. All other particle diameters also began to appear at 30 sec, but followed highly irregular time courses. Infusion of 7 and 15 μm particles caused transient but significant perfusate flow reductions, while infusion of all other diameters caused insignificant reductions in flow. We conclude that small numbers of bypass vessels exist that can accommodate particle diameters of 7-to-50 μm. We further conclude that our 4 μm particle data are consistent with a well-developed network of serial and parallel perfusion pathways at the acinar level. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  19. Plasma ATP concentration and venous oxygen content in the forearm during dynamic handgrip exercise

    Directory of Open Access Journals (Sweden)

    Askew Christopher D

    2009-12-01

    Full Text Available Abstract Background It has been proposed that adenosine triphosphate (ATP released from red blood cells (RBCs may contribute to the tight coupling between blood flow and oxygen demand in contracting skeletal muscle. To determine whether ATP may contribute to the vasodilatory response to exercise in the forearm, we measured arterialised and venous plasma ATP concentration and venous oxygen content in 10 healthy young males at rest, and at 30 and 180 seconds during dynamic handgrip exercise at 45% of maximum voluntary contraction (MVC. Results Venous plasma ATP concentration was elevated above rest after 30 seconds of exercise (P Conclusions Collectively these results indicate that ATP in the plasma originated from the muscle microcirculation, and are consistent with the notion that deoxygenation of the blood perfusing the muscle acts as a stimulus for ATP release. That ATP concentration was elevated just 30 seconds after the onset of exercise also suggests that ATP may be a contributing factor to the blood flow response in the transition from rest to steady state exercise.

  20. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriëtte; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michaël A.; Spronk, Peter E.

    2012-01-01

    Objective: The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design: Prospective observational controlled study. Setting: Nonacademic university-affiliated

  1. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriette; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michael A.; Spronk, Peter E.

    2012-01-01

    Objective:  The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design:  Prospective observational controlled study. Setting:  Nonacademic university-affiliated

  2. Arterio-venous anastomoses in mice affect perfusion measurements with dynamic contrast enhanced CT

    International Nuclear Information System (INIS)

    Gabra, Peter; Lee, Ting-Yim; Shen, Gang; Xuan, Jim

    2010-01-01

    Accurate measurement of perfusion with dynamic contrast enhanced CT requires an arterial input curve (AIC) uncontaminated by venous sources. Arterio-venous anastomoses (AVAs) are sources of contamination if contrast is injected intravenously. We seek to identify AVAs in mice and associated errors in perfusion measurements. Six transgenic mice with spontaneous prostate tumor were scanned with a micro-CT scanner (GE Healthcare (GE)) using a high resolution anatomical and a lower resolution perfusion protocol. For the anatomical protocol, a CT scan was performed during injection of an iodinated contrast agent (Hypaque) into a tail vein. Images covering the thoracic, abdominal and pelvic regions at an isotropic resolution of 175 µm were reconstructed and rendered in 3D to show the arterial and venous tree (Advantage Window, GE). For the perfusion protocol, each mouse was continuously scanned for 40 s and the contrast agent (Hypaque) was injected via a tail vein 5 s into scanning. Tumor images were reconstructed every second. Tumor blood flow (BF) and volume (BV) maps were calculated with CT perfusion software (GE) using AIC measured either from abdominal aorta (AA) or tail (caudal) artery (TA). In all mice, there was an AVA from the bifurcation of the inferior vena cava to the tail artery shunting venous blood and portion of the contrast agent injected into the tail vein into the TA. Contrast arrival time at the TA preceded that at the AA by 3.3 ± 0.5 s (P < 0.05). Mean tumor BV and BF values calculated with AA versus TA were 10.0 ± 1.8 versus 4.8 ± 2.1 ml (100 g) −1 (P < 0.05) and 108.8 ± 26.5 versus 33.0 ± 8.5 ml min −1 100 g −1 (P < 0.05), respectively. AVA in the murine pelvic region can result in inaccurate and more variable measurements of pelvic organ/tissue perfusion when the tail artery is used as the AIC

  3. Coronary arterio-venous fistula associated acute coronary syndrome: A case-report and review of literature

    Directory of Open Access Journals (Sweden)

    V.H. Contreras-Gutiérrez

    2017-01-01

    Full Text Available A 56-year-old woman with no medical history presented to the emergency department complaining of oppressive chest pain of three hours of duration triggered by walking. An electrocardiogram (ECG performed at hospital admission showed ST-segment depression and T-wave inversion in left precordial and inferior leads. Serum troponin I levels were above the normal values. Non ST-segment elevation acute coronary syndrome (NSTEACS was diagnosed and an invasive approach with a percutaneous coronary intervention was performed. No obstructive coronary lesions were observed. However a tortuous coronary fistula emerging from the left-anterior descending coronary artery to the pulmonary artery was observed. Coronary arterio-venous fistulas are present in 0.002% of the general population and in 0.25% of patients undergoing cardiac catheterization for any cause. Most of them are asymptomatic. Ischemic symptoms may develop but are infrequent in patients with no atherosclerotic disease.

  4. Management of a case with misdiagnosed spinal dural arterio-venous fistula.

    Science.gov (United States)

    Lien, Chia-Yi; Lui, Chun-Chung; Lu, Cheng-Hsien; Chang, Wen-Neng

    2014-03-01

    Spinal dural arterio-venous fistula (SDAVF) is an uncommon and easily misdiagnosed vascular malformation. We aimed to report the diagnosis and management of a case with SDAVF. A 62-year-old man suffered from acute paraparesis about 15 months before this study. He underwent a neurosurgical procedure for herniated discs of the cervical spine at that time but there was no relief and the symptoms worsened despite the surgery. Neurologically, he had spastic paraparesis and decreased vibration sensation of the lower limbs. Spinal magnetic resonance imaging (MRI) revealed intra-medullary hyper-intensity lesion at T8 to T10 levels and tubular-like signal void structures in the corresponding posterior sub-arachnoid space. Further trans-arterial angiography through right T6 intercostal artery catheterization revealed engorged veins, thereby confirming the diagnosis of SDAVF. The patient was treated via endovascular embolization (18% Onyx, EV3TM MIT, Bonn, Germany) through spinal angiography and the results showed a marked decrease in engorged veins. After a 4-month follow-up, the patient was symptomatic but stable. Follow-up MRI showed a complete disappearance of the hyper-intensity change of the spinal cord. Spinal MR angiography did not reveal any recurrence of SDAVF. This case study demonstrated the easily misdiagnosed state of SDAVF. Serial neuroimage studies including spinal MRI, endovascular embolization through spinal angiography and MR angiography can be useful tools for its diagnostic confirmation, management and follow-up study.

  5. Severe loin pain following renal biopsy in a high-risk patient: A case report of a rare combination of pseudoaneurysm and arterio-venous fistula

    Directory of Open Access Journals (Sweden)

    Desai Madhav

    2011-01-01

    Full Text Available We report a 50-year-old male patient with diabetes mellitus and hypertension who presented with low-grade fever, anuria and renal failure. He had no prior history of nephropathy and retinopathy. Since anuria persisted, a renal biopsy was performed using automated gun, under ultrasound guidance. Two hours after the renal biopsy was performed, the patient developed severe left loin pain that required analgesics and sedatives. Ultrasound of the abdomen performed immediately, two hours and four hours after the biopsy, did not reveal any hematoma. The hemoglobin was stable when the patient developed loin pain, but after eight hours decreased to 9.1 g/dL, and computed tomography scan of the abdomen revealed a big peri-nephric hematoma around the left kidney. He was managed with blood transfusions and a selective angiogram was done. It revealed a pseudoaneurysm and arterio-venous fistula from the segmental artery of lower pole of the left kidney; both were closed by using microcoils and liquid embolic agent N-butyl-cyanoacrylate (NBCA. The only risk factor the patient had at the time of renal biopsy was severe renal failure. Our case suggests that severe loin pain immediately after renal biopsy in a patient with renal failure warrants careful follow-up of hemoglobin and imaging, even if initial imaging is normal. Further fall of hemoglobin necessitates early evaluation with angiogram, which helps in diagnosing the treatable, although rare, complications like pseudoaneurysm and arterio-venous fistula.

  6. Influence of intranasal and carotid cooling on cerebral temperature balance and oxygenation

    DEFF Research Database (Denmark)

    Nybo, Lars; Wanscher, Michael; Secher, Niels H.

    2014-01-01

    temperatures were measured to assess the cerebral heat balance and corresponding paired blood samples were obtained to evaluate cerebral metabolism and oxygenation at rest, following 60 min of intranasal cooling, 5 min of nasal ventilation, and 15 min with carotid cooling. Intranasal cooling induced a parallel......The present study evaluated the influence of intranasal cooling with balloon catheters, increased nasal ventilation, or percutaneous cooling of the carotid arteries on cerebral temperature balance and oxygenation in six healthy male subjects. Aortic arch and internal jugular venous blood...... drop in jugular venous and arterial blood temperatures by 0.30 ± 0.08°C (mean ± SD), whereas nasal ventilation and carotid cooling failed to lower the jugular venous blood temperature. The magnitude of the arterio-venous temperature difference across the brain remained unchanged at -0.33 ± 0.05°C...

  7. Central venous oxygen saturation during hypovolaemic shock in humans

    DEFF Research Database (Denmark)

    Madsen, P; Iversen, H; Secher, N H

    1993-01-01

    We compared central venous oxygen saturation and central venous pressure (CVP) as indices of the effective blood volume during 50 degrees head-up tilt (anti-Trendelenburg's position) induced hypovolaemic shock in eight healthy subjects. Head-up tilt increased thoracic electrical impedance from 31...... (28-36) (median and range) to 34 (30-40) Ohm, mean arterial pressure (MAP) from 79 (70-88) to 86 (80-99) mmHg, heart rate (HR) from 67 (56-71) to 99 (78-119) beats min-1 (p ....05) but thereafter remained stable. In contrast, central venous oxygen saturation showed a linear decrease with time from 0.75 (0.69-0.78) at rest to 0.60 (0.49-0.67) (p measurement of central venous oxygen saturation...

  8. Surgical planning for microsurgical excision of cerebral arterio-venous malformations using virtual reality technology.

    Science.gov (United States)

    Ng, Ivan; Hwang, Peter Y K; Kumar, Dinesh; Lee, Cheng Kiang; Kockro, Ralf A; Sitoh, Y Y

    2009-05-01

    To evaluate the feasibility of surgical planning using a virtual reality platform workstation in the treatment of cerebral arterio-venous malformations (AVMs) Patient-specific data of multiple imaging modalities were co-registered, fused and displayed as a 3D stereoscopic object on the Dextroscope, a virtual reality surgical planning platform. This system allows for manipulation of 3D data and for the user to evaluate and appreciate the angio-architecture of the nidus with regards to position and spatial relationships of critical feeders and draining veins. We evaluated the ability of the Dextroscope to influence surgical planning by providing a better understanding of the angio-architecture as well as its impact on the surgeon's pre- and intra-operative confidence and ability to tackle these lesions. Twenty four patients were studied. The mean age was 29.65 years. Following pre-surgical planning on the Dextroscope, 23 patients underwent microsurgical resection after pre-surgical virtual reality planning, during which all had documented complete resection of the AVM. Planning on the virtual reality platform allowed for identification of critical feeders and draining vessels in all patients. The appreciation of the complex patient specific angio-architecture to establish a surgical plan was found to be invaluable in the conduct of the procedure and was found to enhance the surgeon's confidence significantly. Surgical planning of resection of an AVM with a virtual reality system allowed detailed and comprehensive analysis of 3D multi-modality imaging data and, in our experience, proved very helpful in establishing a good surgical strategy, enhancing intra-operative spatial orientation and increasing surgeon's confidence.

  9. An arterio-venous bridge for gradual weaning from adult veno-arterial extracorporeal life support.

    Science.gov (United States)

    Babar, Z U D; Sharma, A S; Ganushchak, Y M; Delnoij, T S R; Donker, D W; Maessen, J G; Weerwind, P W

    2015-11-01

    Weaning from extracorporeal life support (ELS) is particularly challenging when cardiac recovery is slow, largely incomplete and hard to predict. Therefore, we describe an individualized gradual weaning strategy using an arterio-venous (AV) bridge incorporated into the circuit to facilitate weaning. Thirty adult patients weaned from veno-arterial ELS using an AV bridge were retrospectively analyzed. Serial echocardiography and hemodynamic monitoring were used to assess cardiac recovery and load responsiveness. Upon early signs of myocardial recovery, an AV bridge with an Hoffman clamp was added to the circuit and weaning was initiated. Support flow was reduced stepwise by 10-15% every 2 to 8 hours while the circuit flow was maintained at 3.5-4.5 L/min. The AV bridge facilitated gradual weaning in all 30 patients (median age: 66 [53-71] years; 21 males) over a median period of 25 [8-32] hours, with a median support duration of 96 [31-181] hours. During weaning, the median left ventricular ejection fraction was 25% [15-32] and the median velocity time integral of the aortic valve was 16 cm [10-23]. Through the weaning period, the mean arterial blood pressure was maintained at 70 mmHg and the activated partial thromboplastin time was 60 ± 10 seconds without additional systemic heparinization. Neither macroscopic thrombus formation in the ELS circuit during and after weaning nor clinically relevant thromboembolism was observed. Incorporation of an AV bridge for weaning from veno-arterial ELS is safe and feasible to gradually wean patients with functional cardiac recovery without compromising the circuit integrity. © The Author(s) 2015.

  10. Hemangiomas versus arterio-venous malformations: Role of elastic stains and mast cell density

    Directory of Open Access Journals (Sweden)

    Pravin Pawane

    2014-01-01

    Full Text Available Context: Vascular anomalies present diagnostic challenges to histopathologists. Mulliken and Glowacki′s classification categorizes vascular lesions into hemangiomas and vascular malformations. Aim: This study explored diagnostic clues in the histomorphology of hemangiomas and vascular malformations. Materials and Methods: A total of 120 cases of benign vascular lesions were retrieved from 12 years period. A total of 94 cases, where complete clinical details and representative paraffin sections were available, were included in this study. Hematoxylin and eosin (H and E stain and Verhoeff′s stain for elastic tissue were done on all cases and lesions were classified into hemangiomas or arterio-venous malformations (AVM. Mast cell density in all lesions was calculated from toluidine blue stained sections. Results: Ten cases of hemangiomas were reclassified as AVM on the basis of presence and absence of arteriovenous structures. Intra-lesional nerves were seen in significantly higher number of AVMs compared to hemangiomas. Medium and thick sized nerve bundles were seen in 56% of AVMs, while they were not seen in any of the hemangiomas. Mean mast cell density was significantly higher in proliferating hemangiomas (53.12 ± 27.83 cells/mm 2 compared to involuting hemangiomas (11.43 ± 7.9 cells/mm 2 . Conclusions: Use of elastic tissue stains are useful ancillary tools to distinguish between AVMs and hemangiomas. The presence of arteries and arterioles are an integral part of AVMs. The presence of the intra-lesional nerves can be useful to distinguish between AVMs and hemangiomas even on H and E stained sections. The significantly higher mast cell density seen in proliferating hemangiomas compared with involuting ones, seem to suggest that mast cells play an important role in the natural history of these lesions.

  11. Apneic oxygenation combined with extracorporeal arteriovenous carbon dioxide removal provides sufficient gas exchange in experimental lung injury

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Kjærgaard, Benedict; Nielsen, Jakob Koefoed

    In this porcine lung injury model, apneic oxygenation with arteriovenous CO2 removal provided sufficient gas exchange and stable hemodynamics, indicating that the method might have a potential in the treatment of severe ARDS.   Acknowledgements The membrane lungs were kindly provided by Novalung GmbH, Germany.......Background and aim of study We hypothesized that continuous high airway pressure without ventilatory movements (apneic oxygenation), using an open lung approach, combined with extracorporeal, pumpless, arterio-venous, carbon dioxide (CO2) removal would provide adequate gas exchange in acute lung...

  12. Core content for training in venous and lymphatic medicine.

    Science.gov (United States)

    Zimmet, Steven E; Min, Robert J; Comerota, Anthony J; Meissner, Mark H; Carman, Teresa L; Rathbun, Suman W; Jaff, Michael R; Wakefield, Thomas W; Feied, Craig F

    2014-10-01

    The major venous societies in the United States share a common mission to improve the standards of medical practitioners, the educational goals for teaching and training programs in venous disease, and the quality of patient care related to the treatment of venous disorders. With these important goals in mind, a task force made up of experts from the specialties of dermatology, interventional radiology, phlebology, vascular medicine, and vascular surgery was formed to develop a consensus document describing the Core Content for venous and lymphatic medicine and to develop a core educational content outline for training. This outline describes the areas of knowledge considered essential for practice in the field, which encompasses the study, diagnosis, and treatment of patients with acute and chronic venous and lymphatic disorders. The American Venous Forum and the American College of Phlebology have endorsed the Core Content. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. Myocardial oxygenation and transmural lactate metabolism during experimental acute coronary stenosis in pigs.

    Science.gov (United States)

    Gonschior, P; Gonschior, G M; Conzen, P F; Hobbhahn, J; Goetz, A E; Peter, K; Brendel, W

    1992-01-01

    Measurement of surface tissue pO2 (ptO2) with surface electrodes is increasingly applied in experimental medicine. Its use on the beating heart may seem to be problematic because transmural gradients of tissue pO2 would reduce the validity of pO2 determinations in the epicardial layers. This study attempted to determine whether ptO2 may be a valid and sensitive indicator of transmural myocardial oxygenation. In order to measure ptO2, two eight-channel Clark-type electrodes were placed on a beating porcine left ventricle (n = 13). Measurements were made at different degrees of acute stenosis of the left anterior descending artery (LAD). A 24-F cannula was inserted into the great cardiac vein, draining the poststenotic myocardium to obtain coronary venous blood samples. Transmural metabolic changes were detected simultaneously by coronary venous blood gas parameters and lactate levels. Epicardial tissue pO2 was 49 +/- 2 mm Hg (mean +/- SEM) before stenosis and decreased to a mean value of 25 +/- 2 mm Hg during stenosis. Different degrees of LAD stenosis (ptO2 range: 12-35 mm Hg) were substantial enough to alter arterio-coronary venous lactate difference (avd lactate) from +0.31 +/- 0.07 mmol/l (control) to -0.62 +/- 0.15 mmol/l (stenosis). A significant linear correlation between changes of ptO2 (delta ptO2) and changes of avd lactate (delta avd lactate) resulted (y = 0.59 + 0.62x; r = 0.86; p less than or equal to 0.001). However, linear regression analysis between delta ptO2 correlated with the corresponding data from coronary venous pO2 (delta pO2cv) oxygen content (delta O2contcv), and oxygen saturation (delta O2satcv) showed no significant correlations. We conclude that measurement of ptO2 is a sensitive and valuable indicator of transmural oxygenation in ischemic myocardium, whereas pO2cv, O2contcv and O2satcv do not seem to be valid predictors of ischemia in myocardial oxygenation.

  14. MALFORMACIÓN ARTERIO VENOSA CERVICAL COMPLEJA SINTOMÁTICA

    OpenAIRE

    Bombin F,Juan; Kotlik A,Alejandro; Seguel S,Gabriel; Pizarro S,Carla; Aliaga S,Erik

    2015-01-01

    Introducción: Las Malformaciones Arterio-Venosas (MAV) son alteraciones estructurales congénitas del desarrollo del sistema vascular en que se observan comunicaciones anómalas arterio-venosas conformando un "nido" arterio-venoso-capilar. Caso Clínico: Mujer que consulta a los 15 años de edad por una MAV en la región cervical posterior izquierda desde su nacimiento. Se efectúa una resección amplia de la lesión hasta el plano aponeurótico cubriendo el defecto con un colgajo de rotación cutáneo-...

  15. [Near-infrared spectroscopy in sepsis therapy : predictor of a low central venous oxygen saturation].

    Science.gov (United States)

    Lichtenstern, C; Koch, C; Röhrig, R; Rosengarten, B; Henrich, M; Weigand, M A

    2012-10-01

    Early goal-directed hemodynamic optimization has become a cornerstone of sepsis therapy. One major defined goal is to achieve adequate central venous oxygen saturation (SO(2)). This study aimed to investigate the correlation between central venous SO(2) and frontal cerebral near-infrared spectroscopy (NIRS) measurement in patients with severe sepsis and septic shock. The NIRS method provides non-invasive measurement of regional oxygen saturation (rSO(2)) in tissues approximately 2 cm below the optical NIRS sensors which depends on arterial, capillary and venous blood. Thus this system gives site-specific real-time data about the balance of oxygen supply and demand. This was a secondary analysis from a prospective study of surgical intensive care (ICU) patients in the early phase of severe sepsis or septic shock. Bilateral cerebral rSO(2), central venous SO(2), arterial oxygen saturation (S(a)O(2)) and other surrogate parameters of oxygen supply, such as hemoglobin, partial pressure of oxygen and oxygen content in arterial blood were recorded. A total of 16 ICU patients (4 women, median age 65.5 years) were included in the study. As sepsis focus an intra-abdominal infection was detected in 62.5 % of patients, severe pneumonia was determined in 31.3 % and skin and soft tissue infections were recognized in 12.5 %. At study inclusion 50 % of patients had septic shock, the median sequential organ failure assessment (SOFA) score was 10.2 (interquartile range 5.25-8.75) and the median acute physiology and chronic health evaluation II (APACHE II) score was 26 (range 23.25-29.75). Mortality at day 28 was 37.5 %. Minimum rSO(2) (median 58) and right-sided rSO(2) (median 58) values showed a significant correlation in the analysis of receiver operating characteristics (area under the curve 0.844, p= 0.045). A central venous SO(2)< 70 % was indicated by rSO(2)< 56.5 with sensitivity and specificity of 75 % and 100 %, respectively. Cerebral NIRS could provide a fast and easily

  16. Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage

    Science.gov (United States)

    Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.

  17. ATP-induced temperature independence of hemoglobin-O2 affinity in heterothermic billfish

    DEFF Research Database (Denmark)

    Weber, Roy E.; Campbell, Kevin L.; Fago, Angela

    2010-01-01

    heterotherms, where it may hamper unloading (e.g. in cold extremities of arctic mammals) or increase the diffusive arterio-venous short-circuiting of O2 (e.g. in counter-current heat exchangers of warm swimming muscles of tuna). We hypothesized analogous blood specializations in heterothermic billfish, whose......The inverse relationship between temperature and hemoglobin-O2 affinity resulting from the exothermic nature of heme oxygenation favors O2 unloading from blood to warm, metabolically active tissues. However, this temperature sensitivity is maladaptive, and commonly countered in regional...... to allosterically modulating hemoglobin-O2 affinity, ATP diminishes its temperature sensitivity, reducing deleterious arterio-venous short-circuiting of oxygen in the cranial billfish heat exchangers. The mechanism underlying this reduction in oxygenation enthalpy differs fundamentally from that in tuna, supporting...

  18. Central venous oxygenation: when physiology explains apparent discrepancies.

    Science.gov (United States)

    Squara, Pierre

    2014-11-10

    Central venous oxygen saturation (ScvO2) >70% or mixed venous oxygen saturation (SvO2) >65% is recommended for both septic and non-septic patients. Although it is the task of experts to suggest clear and simple guidelines, there is a risk of reducing critical care to these simple recommendations. This article reviews the basic physiological and pathological features as well as the metrological issues that provide clear evidence that SvO2 and ScvO2 are adaptative variables with large inter-patient variability. This variability is exemplified in a modeled population of 1,000 standard ICU patients and in a real population of 100 patients including 15,860 measurements. In these populations, it can be seen how optimizing one to three of the four S(c)vO2 components homogenized the patients and yields a clear dependency with the fourth one. This explains the discordant results observed in large studies where cardiac output was increased up to predetermined S(c)vO2 thresholds following arterial oxygen hemoglobin saturation, total body oxygen consumption needs and hemoglobin optimization. Although a systematic S(c)vO2 goal-oriented protocol can be statistically profitable before ICU admission, appropriate intensive care mandates determination of the best compromise between S(c)vO2 and its four components, taking into account the specific constraints of each individual patient.

  19. Neuropsychologic changes in patients with arterio-venous malformation (AVM) after radiosurgery

    International Nuclear Information System (INIS)

    Steinvorth, S.; Wenz, F.; Wildermuth, S.; Fuss, M.; Debus, J.; Lohr, F.; Wannenmacher, M.

    1997-01-01

    Purpose/Objective: Cerebral AVM are inborn malformations which may become symptomatic in young adult patients by hemorrhage, seizures or steal syndromes. Depending on size, location and drainage, there is a risk for rupture with potentially devastating consequences. Treatment options include neurosurgery, embolization or radiosurgery. The radiosensitivity of normal brain tissue is the main limitation for radiotherapy of CNS tumors. Improved treatment planning and irradiation techniques, however, minimize the dose to unaffected brain tissue. The purpose of this study was to investigate the neuropsychological effects of radiosurgical treatment in patients with cerebral AVM. Materials and Methods: Forty-four patients with cerebral arterio-venous malformations were included into the study. Patients with hemiparesis, aphasia or hemianopia were excluded from testing. The patients were examined the day before (n=44), acutely after radiosurgery (n=23) and during the regular follow-up (subacute phase n=21, chronic phase n=12). Radiosurgery was performed using a modified linear accelerator and either rotations of 9 non-coplanar arcs or 15 individually collimated, isocentric, non-coplanar fields. Doses of 15 - 22 Gy (median 20 Gy) were prescribed to the 80% isodose (minimum dose to the target volume). The dose to the total brain was calculated as 0.5 to 2 Gy depending on dose, location and size of the target volume. The neuropsychological testing was done using a computer assisted testing facility allowing standardized testing conditions. The extensive testing battery included assessment of general intelligence (shortened version Wechsler Adult Intelligence Scale), attention (Digit Symbol Test (DST), D2 test (D2), a letter cancellation test, a modified Trail Making Test A (ZVT), and the WDG measuring the reaction time in a complex signal-reaction-situation) and memory (Benton Visual Retention Test (BVRT), Rey Auditory Verbal Learning Test (RAVLT), Cube test). Testing during

  20. Monitoring mixed venous oxygen saturation in patients with obstructive shock after massive pulmonary embolism.

    Science.gov (United States)

    Krivec, Bojan; Voga, Gorazd; Podbregar, Matej

    2004-05-31

    Patients with massive pulmonary embolism and obstructive shock usually require hemodynamic stabilization and thrombolysis. Little is known about the optimal and proper use of volume infusion and vasoactive drugs, or about the titration of thrombolytic agents in patients with relative contraindication for such treatment. The aim of the study was to find the most rapidly changing hemodynamic variable to monitor and optimize the treatment of patients with obstructive shock following massive pulmonary embolism. Ten consecutive patients hospitalized in the medical intensive care unit in the community General Hospital with obstructive shock following massive pulmonary embolism were included in the prospective observational study. Heart rate, systolic arterial pressure, central venous pressure, mean pulmonary-artery pressure, cardiac index, total pulmonary vascular-resistance index, mixed venous oxygen saturation, and urine output were measured on admission and at 1, 2, 3, 4, 8, 12, and 16 hours. Patients were treated with urokinase through the distal port of a pulmonary-artery catheter. At 1 hour, mixed venous oxygen saturation, systolic arterial pressure and cardiac index were higher than their admission values (31+/-10 vs. 49+/-12%, p<0.0001; 86+/-12 vs. 105+/-17 mmHg, p<0.01; 1.5+/-0.4 vs. 1.9+/-0.7 L/min/m2, p<0.05; respectively), whereas heart rate, central venous pressure, mean pulmonary-artery pressure and urine output remained unchanged. Total pulmonary vascular-resistance index was lower than at admission (29+/-10 vs. 21+/-12 mmHg/L/min/m2, p<0.05). The relative change of mixed venous oxygen saturation at hour 1 was higher than the relative changes of all other studied variables (p<0.05). Serum lactate on admission and at 12 hours correlated to mixed venous oxygen saturation (r=-0.855, p<0.001). In obstructive shock after massive pulmonary embolism, mixed venous oxygen saturation changes more rapidly than other standard hemodynamic variables.

  1. Severe hypoxemia during veno-venous extracorporeal membrane oxygenation: exploring the limits of extracorporeal respiratory support

    Directory of Open Access Journals (Sweden)

    Liane Brescovici Nunes

    2014-03-01

    Full Text Available OBJECTIVE: Veno-venous extracorporeal oxygenation for respiratory support has emerged as a rescue alternative for patients with hypoxemia. However, in some patients with more severe lung injury, extracorporeal support fails to restore arterial oxygenation. Based on four clinical vignettes, the aims of this article were to describe the pathophysiology of this concerning problem and to discuss possibilities for hypoxemia resolution. METHODS: Considering the main reasons and rationale for hypoxemia during veno-venous extracorporeal membrane oxygenation, some possible bedside solutions must be considered: 1 optimization of extracorporeal membrane oxygenation blood flow; 2 identification of recirculation and cannula repositioning if necessary; 3 optimization of residual lung function and consideration of blood transfusion; 4 diagnosis of oxygenator dysfunction and consideration of its replacement; and finally 5 optimization of the ratio of extracorporeal membrane oxygenation blood flow to cardiac output, based on the reduction of cardiac output. CONCLUSION: Therefore, based on the pathophysiology of hypoxemia during veno-venous extracorporeal oxygenation support, we propose a stepwise approach to help guide specific interventions.

  2. Filterability of freshly-collected sickle erythrocytes under venous oxygen pressure without exposure to air.

    Science.gov (United States)

    Shah, Siddharth; Acholonu, Rhonda Graves; Ohene-Frempong, Kwaku; Asakura, Toshio

    2015-12-01

    We previously found that blood samples collected from steady-state patients with sickle cell disease (SCD) without exposure to air contain a new type of reversibly sickled cells (RSCs) with blunt edges at a level of as high as 78%. Since partial oxygenation of once-deoxygenated sickled cells with pointy edges to near venous oxygen pressure generates similar sickled cells with blunt edges in vitro, we named them as partially oxygenated sickled cells (POSCs). On the other hand, partial deoxygenation of once-oxygenated SS cells to venous oxygen pressure generates partially deoxygenated sickled cells (PDSCs) with pointy edges. In this study, we obtained blood samples from 6 steady-state patients with SCD under venous oxygen pressure without exposure to air, subjected them to various oxygenation/deoxygenation/reoxygenation cycles, and studied their filterability through a membrane filter with pore diameter of 3μm, the theoretical minimum diameter of a capillary. Our results indicated that discocytes, POSCs with blunt edges, and irreversibly sickled cells could deform and pass through the filter, while PDSCs with pointy edges were rigid and could not. The filterability of SS cells seems to be related to the length and amount of deoxy-hemoglobin S fibers in the cells. Copyright © 2015. Published by Elsevier Inc.

  3. A novel approach to the management of critically ill neonatal Ebstein's anomaly: Veno-venous extracorporeal membrane oxygenation to promote right ventricular recovery.

    Science.gov (United States)

    Bauser-Heaton, Holly; Nguyen, Charles; Tacy, Theresa; Axelrod, David

    2015-01-01

    This is the first report of the use of veno-venous extracorporeal membrane oxygenation in a neonate with severe Ebstein's anomaly. The report suggests the use of veno-venous extracorporeal membrane oxygenation in the immediate neonatal period may be a useful therapy in severe Ebstein's anomaly. By providing adequate oxygenation independent of the patient's native pulmonary blood flow, veno-venous extracorporeal membrane oxygenation allows the pulmonary vascular resistance to decrease and may promote right ventricular recovery.

  4. Consensus Document of the International Union of Angiology (IUA)-2013. Current concept on the management of arterio-venous management.

    Science.gov (United States)

    Lee, B B; Baumgartner, I; Berlien, H P; Bianchini, G; Burrows, P; Do, Y S; Ivancev, K; Kool, L S; Laredo, J; Loose, D A; Lopez-Gutierrez, J C; Mattassi, R; Parsi, K; Rimon, U; Rosenblatt, M; Shortell, C; Simkin, R; Stillo, F; Villavicencio, L; Yakes, W

    2013-02-01

    Arterio-venous malformations (AVMs) are congenital vascular malformations (CVMs) that result from birth defects involving the vessels of both arterial and venous origins, resulting in direct communications between the different size vessels or a meshwork of primitive reticular networks of dysplastic minute vessels which have failed to mature to become 'capillary' vessels termed "nidus". These lesions are defined by shunting of high velocity, low resistance flow from the arterial vasculature into the venous system in a variety of fistulous conditions. A systematic classification system developed by various groups of experts (Hamburg classification, ISSVA classification, Schobinger classification, angiographic classification of AVMs,) has resulted in a better understanding of the biology and natural history of these lesions and improved management of CVMs and AVMs. The Hamburg classification, based on the embryological differentiation between extratruncular and truncular type of lesions, allows the determination of the potential of progression and recurrence of these lesions. The majority of all AVMs are extra-truncular lesions with persistent proliferative potential, whereas truncular AVM lesions are exceedingly rare. Regardless of the type, AV shunting may ultimately result in significant anatomical, pathophysiological and hemodynamic consequences. Therefore, despite their relative rarity (10-20% of all CVMs), AVMs remain the most challenging and potentially limb or life-threatening form of vascular anomalies. The initial diagnosis and assessment may be facilitated by non- to minimally invasive investigations such as duplex ultrasound, magnetic resonance imaging (MRI), MR angiography (MRA), computerized tomography (CT) and CT angiography (CTA). Arteriography remains the diagnostic gold standard, and is required for planning subsequent treatment. A multidisciplinary team approach should be utilized to integrate surgical and non-surgical interventions for optimum

  5. The analysis of cerebro-vascular circulation time using digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Han, D. G.; Kim, D. H.; Lee, H. K.; Kwon, K. H.; Kim, K. J.

    1986-01-01

    We analyzed the cerebral arterio-venous circulation time of 141 cases of cranial DSA in 136 patients, for the assessment of cerebral circulatory dynamics. IV-DSA was 111 cases, IA-DSA 30 cases. The results were as follows: 1. There was no significant difference in arterio-venous circulation time between IA-DSA and IV-DSA, if the disease pattern was not considered (P > 0.1). 2. Prolongation of arterio-venous circulation time was noted in the cases of cerebral (cerebellar) hemorrhage, subarachnoid hemorrhage, intracranial hematoma, brain abscess, acute stage of cerebra-vascular occlusive disease, acute stage of postoperative follow up, and acute stage of cerebral contusion (p > 0.05). 3. Compared the chronic stage of cerebra-vascular occlusive disease, postoperative follow up, and cerebral contusion with acute stage, significant decrement of arterio-venous circulation time was resulted (p > 0.05). 4. DSA was a useful modality for the assessment of circulatory dynamics, including measurement of arterio-venous circulation time.

  6. Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.

    Science.gov (United States)

    Collins, Julie-Ann; Rudenski, Aram; Gibson, John; Howard, Luke; O'Driscoll, Ronan

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (S O2 ) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin-oxygen dissociation curve, a graphical representation of the relationship between oxygen satur-ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the S O2 in blood from patients with normal pH and S O2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (S pO2 ) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (S aO2 ) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable S pO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  7. Relating oxygen partial pressure, saturation and content: the haemoglobin–oxygen dissociation curve

    Directory of Open Access Journals (Sweden)

    Julie-Ann Collins

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content, saturation (SO2 and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin–oxygen dissociation curve, a graphical representation of the relationship between oxygen satur­ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the SO2 in blood from patients with normal pH and SO2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (SpO2 is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (SaO2 as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable SpO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  8. Research

    African Journals Online (AJOL)

    ebutamanya

    3 sept. 2015 ... 1Service d'Anesthésie-réanimation, Hôpital des Spécialités, Centre Hospitalier .... anesthésique était essentiellement du a la disponibilité du produit et .... Changes of blood pressure and cerebral arterio-venous oxygen.

  9. Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock

    OpenAIRE

    Mo?ina, Hugo; Podbregar, Matej

    2010-01-01

    Introduction Discrepancies of 5-24% between superior vena cava oxygen saturation (ScvO2) and mixed venous oxygen saturation (SvO2) have been reported in patients with severe heart failure. Thenar muscle tissue oxygenation (StO2) measured with near-infrared spectroscopy (NIRS) during arterial occlusion testing decreases slower in sepsis/septic shock patients (lower StO2 deoxygenation rate). The StO2 deoxygenation rate is influenced by dobutamine. The aim of this study was to determine the rela...

  10. Super selective uterine arterio-embolization in treating uterine myoma

    International Nuclear Information System (INIS)

    Gu Yaqin; Wang Jiangu; Shang Jinyun; Zhang Jian; Zhang Rulan; Tan Yuedi; Zhao Zehua; Xu Chongsen

    2001-01-01

    Objective: To study the clinical efficacy of super selective uterine arterio-embolization in treating uterine myoma. Methods: From February to August 2000, 28 cases of uterine myomas were under-gone bilateral arterio-embolization of tumor feeding vessels. Results: The successful rate of embolization catheterization reached 100%. B-mode ultrasound examination revealed the following during 1-6 months after the procedure, with an average shrinkage of 25% in volume for all cases in the first month follow up, complete disappearance of tumor in 8 cases and with an average shrinkage of 68% volumetrically for the other 20 cases, together with conspicuous decrease in volume of menstruation. Conclusions: Interventional treatment for uterine myoma is definite effective especially in submucosal uterine myoma

  11. A novel approach to the management of critically ill neonatal Ebstein′s anomaly: Veno-venous extracorporeal membrane oxygenation to promote right ventricular recovery

    Directory of Open Access Journals (Sweden)

    Holly Bauser-Heaton

    2015-01-01

    Full Text Available This is the first report of the use of veno-venous extracorporeal membrane oxygenation in a neonate with severe Ebstein′s anomaly. The report suggests the use of veno-venous extracorporeal membrane oxygenation in the immediate neonatal period may be a useful therapy in severe Ebstein′s anomaly. By providing adequate oxygenation independent of the patient′s native pulmonary blood flow, veno-venous extracorporeal membrane oxygenation allows the pulmonary vascular resistance to decrease and may promote right ventricular recovery.

  12. Dependence of diameters and oxygen saturation of retinal vessels on visual field damage and age in primary open-angle glaucoma.

    Science.gov (United States)

    Ramm, Lisa; Jentsch, Susanne; Peters, Sven; Sauer, Lydia; Augsten, Regine; Hammer, Martin

    2016-05-01

    To investigate the interrelationship between the oxygen supply of the retina and its regulation with the severity of primary open-angle glaucoma (POAG). Central retinal artery (CRAE) and vein (CRVE) diameters and oxygen saturation of peripapillary retinal vessels in 41 patients suffering from POAG (64.1 ± 12.9 years) and 40 healthy volunteers (63.6 ± 14.1 years) were measured using the retinal vessel analyzer. All measures were taken before and during flicker light stimulation. The mean retinal nerve fiber layer thickness (RNFLT) was determined by OCT and the visual field mean defect (MD) was identified using perimetry. In glaucoma patients, CRAE (r = -0.48 p = 0.002) and CRVE (r = -0.394 p = 0.014) at baseline were inversely related to MD, while arterial and venous oxygen saturation showed no significant dependence on the severity of the damage. However, the flicker light-induced change in arterio-venous difference in oxygen saturation was correlated with the MD (r = 0.358 p = 0.027). The diameters of arteries and veins at baseline decreased with reduction of the mean RNFLT (arteries: r = 0.718 p field loss, may be explained by a reduction of the retinal metabolic demand with progressive loss of neuronal tissue in glaucoma. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Improvement in retinal venous oxygen saturation after panretinal photocoagulation is predictive of progression of proliferative diabetic retinopathy

    DEFF Research Database (Denmark)

    Torp, Thomas Lee; Kawasaki, Ryo; Wong, Tien Yin

    blood pressure was 152/84mmHg. Retinal arterial and venous saturation was 96.7% and 67.4%, respectively. Patients in Group 1 and 2 did not differ in baseline retinal arterial and venous oxygen saturation, number of laser spots delivered, total laser energy delivered, or change in retinal arterial oxygen...... patients with diagnosed PDR were included. We performed wide-field fluorescein angiography (WFA) (Optomap; Optos PLC., Dunfermline, Scotland, UK) and retinal oximetry (Oxymap model T1; Oxymap, software version 2.4.2, Reykjavik, Iceland) at baseline and three months after PRP by a navigated laser (NAVILAS...

  14. Calculating acid-base and oxygenation status during COPD exacerbation using mathematically arterialised venous blood

    DEFF Research Database (Denmark)

    Rees, Stephen Edward; Rychwicka-Kielek, Beate A; Andersen, Bjarne F

    2012-01-01

    Abstract Background: Repeated arterial puncture is painful. A mathematical method exists for transforming peripheral venous pH, PCO2 and PO2 to arterial eliminating the need for arterial sampling. This study evaluates this method to monitor acid-base and oxygenation during admission...... for exacerbation of chronic obstructive pulmonary disease (COPD). Methods: Simultaneous arterial and peripheral venous blood was analysed. Venous values were used to calculate arterial pH, PCO2 and PO2, with these compared to measured values using Bland-Altman analysis and scatter plots. Calculated values of PO2......H, PCO2 and PO2 were 7.432±0.047, 6.8±1.7 kPa and 9.2±1.5 kPa, respectively. Calculated and measured arterial pH and PCO2 agreed well, differences having small bias and SD (0.000±0.022 pH, -0.06±0.50 kPa PCO2), significantly better than venous blood alone. Calculated PO2 obeyed the clinical rules...

  15. A content validated questionnaire for assessment of self reported venous blood sampling practices.

    Science.gov (United States)

    Bölenius, Karin; Brulin, Christine; Grankvist, Kjell; Lindkvist, Marie; Söderberg, Johan

    2012-01-19

    Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

  16. The contribution of intrapulmonary shunts to the alveolar-to-arterial oxygen difference during exercise is very small

    DEFF Research Database (Denmark)

    Vogiatzis, Ioannis; Zakynthinos, Spyros; Boushel, Robert

    2008-01-01

    Exercise is well known to cause arterial PO2 to fall and the alveolar-arterial PO2 difference(Aa PO2 ) to increase. Until recently, the physiological basis for this was considered to be mostly ventilation/perfusion ((.)VA/(.)Q) inequality and alveolar-capillary diffusion limitation. Recently......, arterio-venous shunting through dilated pulmonary blood vessels has been proposed to explain a significant part of the Aa PO2 during exercise. To test this hypothesis we determined venous admixture during 5 min of near-maximal, constant-load, exercise in hypoxia (in inspired O2 fraction, FIO2 , 0...... venous admixture, Aa PO2 and hypoxaemia during heavy exercise....

  17. A content validated questionnaire for assessment of self reported venous blood sampling practices

    Directory of Open Access Journals (Sweden)

    Bölenius Karin

    2012-01-01

    Full Text Available Abstract Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

  18. Central venous oxygen saturation in septic shock - a marker of cardiac output, microvascular shunting and/or dysoxia?

    DEFF Research Database (Denmark)

    Haase, Nicolai; Perner, Anders

    2011-01-01

    Shock therapy aims at increasing central venous oxygen saturation (ScvO2), which is a marker of inadequate oxygen delivery. In this issue of Critical Care, Textoris and colleagues challenge this notion by reporting that high levels of ScvO2 are associated with mortality in patients with septic sh...

  19. Simultaneous estimation of arterial and venous oxygen saturation using a camera

    Science.gov (United States)

    van Gastel, Mark; Liang, Hangbing; Stuijk, Sander; de Haan, Gerard

    2018-02-01

    Optical monitoring of arterial blood oxygenation, SpO2, using cameras has recently been shown feasible by measuring the relative amplitudes of the remotely sensed PPG waveforms captured at different wavelengths. SvO2 measures the venous blood oxygenation which together with SpO2 provides an indication of tissue oxygen consumption. In contrast to SpO2 it usually still requires a blood sample from a pulmonary artery catheter. In this work we present a method which suggests simultaneous estimation of SpO2 and SvO2 with a camera. Contrary to earlier work, our method does not require external cuffs leading to better usability and improved comfort. Since the arterial blood varies synchronously with the heart rate, all frequencies outside the heart rate band are typically filtered out for SpO2 measurements. For SvO2 estimation, we include intensity variations in the respiratory frequency range since respiration modulates venous blood due to intrathoracic pressure variations in the chest and abdomen. Consequently, under static conditions, the two dominant components in the PPG signals are respiration and pulse. By measuring the amplitude ratios of these components, it seems possible to monitor both SpO2 and SvO2 continuously. We asked healthy subjects to follow an auditory breathing pattern while recording the face and hand. Results show a difference in estimated SpO2 and SvO2 values in the range 5-30 percent for both anatomical locations, which is normal for healthy people. This continuous, non-contact, method shows promise to alert the clinician to a change in patient condition sooner than SpO2 alone.

  20. Optoacoustic measurement of central venous oxygenation for assessment of circulatory shock: clinical study in cardiac surgery patients

    Science.gov (United States)

    Petrov, Irene Y.; Prough, Donald S.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock is a dangerous medical condition, in which blood flow cannot provide the necessary amount of oxygen to organs and tissues. Currently, its diagnosis and therapy decisions are based on hemodynamic parameters (heart rate, blood pressure, blood gases) and mental status of a patient, which all have low specificity. Measurement of mixed or central venous blood oxygenation via catheters is more reliable, but highly invasive and associated with complications. Our previous studies in healthy volunteers demonstrated that optoacoustic systems provide non-invasive measurement of blood oxygenation in specific vessels, including central veins. Here we report our first results of a clinical study in coronary artery bypass graft (CABG) surgery patients. We used a medical-grade OPO-based optoacoustic system developed in our laboratory to measure in real time blood oxygenation in the internal jugular vein (IJV) of these patients. A clinical ultrasound imaging system (GE Vivid e) was used for IJV localization. Catheters were placed in the IJV as part of routine care and blood samples taken via the catheters were processed with a CO-oximeter. The optoacoustic oxygenation data were compared to the CO-oximeter readings. Good correlation between the noninvasive and invasive measurements was obtained. The results of these studies suggest that the optoacoustic system can provide accurate, noninvasive measurements of central venous oxygenation that can be used for patients with circulatory shock.

  1. Oxygen effect and intracellular oxygen content (adaptation hypothesis)

    Energy Technology Data Exchange (ETDEWEB)

    Yarmonenko, S P; Ehpshtejn, I M [Akademiya Meditsinskikh Nauk SSSR, Moscow. Onkologicheskij Tsentr

    1977-01-01

    Experimental data indicating that a radiomodifying action of hypoxia is dependent on the ''prehistory'' of the irradiated object are considered. This dependence manifests itself in a decreased protective action of acute hypoxia on the hypoxia-adapted objects. To explain this a hypothesis is proposed connecting a degree of cell radiosensitivity modification, determined by the oxygen effect, with the intracellular oxygen content. The latter, in accord with current ideas, is regulated by variations in the diffusion resistance to oxygen shown by the cytoplasmic membranes depending on the energy level of the cell and the degree of its oxygenation.

  2. Oxygen effect and intracellular oxygen content (adaptation hypothesis)

    International Nuclear Information System (INIS)

    Yarmonenko, S.P.; Ehpshtejn, I.M.

    1977-01-01

    Experimental data indicating that a radiomodifying action of hypoxia is dependent on the ''prehistory'' of the irradiated object are considered. This dependence manifests itself in a decreased protective action of acute hypoxia on the hypoxia-adapted objects. To explain this a hypothesis is proposed connecting a degree of cell radiosensitivity modification, determined by the oxygen effect, with the intracellular oxygen content. The latter, in accord with current ideas, is regulated by variations in the diffusion resistance to oxygen shown by the cytoplasmic membranes depending on the energy level of the cell and the degree of its oxygenation

  3. Improvement of Oxygenation in Severe Acute Respiratory Distress Syndrome With High-Volume Continuous Veno-venous Hemofiltration.

    Science.gov (United States)

    Yang, Wenmin; Hong, Jie; Zeng, Qiyi; Tao, Jianping; Chen, Feiyan; Dang, Run; Liang, Yufeng; Wu, Zhiyuan; Yang, Yiyu

    2016-01-01

    The efficacy and therapeutic mechanisms of continuous renal replacement therapy (CRRT) for improvement of oxygenation in acute respiratory distress syndrome (ARDS) remain controversial. These questions were addressed by retrospective analysis of severe ARDS patients admitted to the pediatric intensive care unit of our hospital from 2009 to 2015 who received high-volume continuous veno-venous hemofiltration during mechanical ventilation. There was a significant improvement in partial oxygen pressure/fraction of inspired oxygen (PaO2/FiO2) 24 hours after CRRT onset compared with baseline (median change = 51.5; range = -19 to 450.5; P Improvement in oxygenation is likely related to both restoration of fluid balance and clearance of inflammatory mediators.

  4. Mechanisms controlling the oxygen consumption in experimentally induced hypochloremic alkalosis in calves.

    Science.gov (United States)

    Cambier, Carole; Clerbaux, Thierry; Amory, Hélène; Detry, Bruno; Florquin, Sandra; Marville, Vincent; Frans, Albert; Gustin, Pascal

    2002-01-01

    The study was carried out on healthy Friesian calves (n = 10) aged between 10 and 30 days. Hypochloremia and alkalosis were induced by intravenous administration of furosemide and isotonic sodium bicarbonate. The venous and arterial blood samples were collected repeatedly. 2,3-diphosphoglycerate (2,3-DPG), hemoglobin and plasmatic chloride concentrations were determined. The red blood cell chloride concentration was also calculated. pH, PCO2 and PO2 were measured in arterial and mixed venous blood. The oxygen equilibrium curve (OEC) was measured in standard conditions. The correspondence of the OEC to the arterial and mixed venous compartments was calculated, taking blood temperature, pH and PCO2 values into account. The oxygen exchange fraction (OEF%), corresponding to the degree of blood desaturation between the arterial and mixed venous compartments and the amount of oxygen released at the tissue level by 100 mL of blood (OEF Vol%) were calculated from the arterial and mixed venous OEC, combined with PO2 and hemoglobin concentration. Oxygen delivery (DO2) was calculated using the arterial oxygen content, the cardiac output measured by thermodilution, and the body weight of the animal. The oxygen consumption (VO2) was derived from the cardiac output, OEF Vol% and body weight values. Despite the plasma hypochloremia, the erythrocyte chloride concentration was not influenced by furosemide and sodium bicarbonate infusion. Due to the alkalosis-induced increase in the 2,3-DPG, the standard OEC was shifted to the right, allowing oxygen to dissociate from hemoglobin more rapidly. These changes opposed the increased affinity of hemoglobin for oxygen induced by alkalosis. Moreover, respiratory acidosis, hemoconcentration, and the slight decrease in the partial oxygen pressure in mixed venous blood (Pvo2) tended to improve the OEF Vol% and maintain the oxygen consumption in a physiological range while the cardiac output, and the oxygen delivery were significantly decreased

  5. Volcano-like intermittent bleeding activity for seven years from an arterio-enteric fistula on a kidney graft site after pancreas-kidney transplantation: a case report

    Directory of Open Access Journals (Sweden)

    Schölmerich Jürgen

    2010-11-01

    Full Text Available Abstract Introduction We report the first case of a patient who underwent simultaneous kidney and pancreas transplantation and who then suffered from repeated episodes of severe gastrointestinal bleeding over a period of seven years. Locating the site of gastrointestinal bleeding is a challenging task. This case illustrates that detection of an arterio-enteric fistula can be very difficult, especially in technically-challenging situations such as cases of severe intra-abdominal adhesions. It is important to consider the possibility of arterio-enteric fistulas in cases of intermittent bleeding episodes, especially in transplant patients. Case presentation A 40-year-old Caucasian man received a combined pancreas-kidney transplantation as a result of complications from diabetes mellitus type I. Thereafter, he suffered from intermittent clinically-relevant episodes of gastrointestinal bleeding. Repeat endoscopic, surgical, scintigraphic, and angiographic investigations during his episodes of acute bleeding could not locate the bleeding site. He finally died in hemorrhagic shock due to arterio-enteric bleeding at the kidney graft site, which was diagnosed post-mortem. Conclusions In accordance with the literature, we suggest considering the removal of any rejected transplant organs in situations where arterio-enteric fistulas seem likely but cannot be excluded by repeat conventional or computed tomography-angiographic methods. Arterio-enteric fistulas may intermittently bleed over many years.

  6. Neuropathy in the hemodialysis population: a review of neurophysiology referrals in a tertiary center.

    LENUS (Irish Health Repository)

    O'Regan, John

    2012-01-01

    This was a retrospective observational study of neurophysiology referrals over 8 years from a tertiary referral center in Ireland. A total of 68 of the 73 referrals yielded one or more abnormalities. Thirty-nine (53%) patients had one or more mononeuropathies; iatrogenic mononeuropathies believed to be associated with arterio-venous fistula creation occurred in 15 patients. Polyneuropathy was identified in 43 patients (59%). Access to an experienced neurophysiology department offers valuable insight into dialysis-associated neuropathies, especially when associated with arterio-venous fistulae.

  7. Stewart-Bluefarb acroangiodermatitis in a case of Parkes-Weber syndrome

    Directory of Open Access Journals (Sweden)

    Deepti H Ghia

    2014-01-01

    Full Text Available Stewart-Bluefarb acroangiodermatitis is the occurrence of pseudo-kaposiform changes with an underlying arterio-venous malformation. Parkes-Weber syndrome is a triad of arterio-venous malformation with varicose veins with bony and soft-tissue hypertrophy involving the extremity. A 13 year-old-female presented with ulcerated growth with bleeding episodes on right leg since past four years. A reddish discoloration over right leg was noticed at four years of age which remained unchanged until nine years of age, after which it showed rapid increase in size along with disproportionate increase in length and girth of right lower limb. Examination revealed hyperpigmented soft verrucous plaque over the right lower one-third of leg, along with presence of ulcers and dilated tortuous veins in the right lower leg with thrill and bruit over the right popliteal and inguinal region. A differential diagnosis of verrucous hemangioma and arterio-venous malformation with pseudo-kaposiform change was considered. Skin biopsy showed multiple fenestrated capillaries with perivascular lymphocyte infiltrate suggestive of capillary malformations. X-ray showed osteolytic defect in right tibia. Duplex ultrasound and magnetic resonance imaging of right leg showed multiple fast flowing small and medium sized arterio-venous malformations of small to moderate size. Thus, on the basis of clinical and radiological features, we made a diagnosis of Stewart-Bluefarb type of acroangiodermatitis with Parkes-Weber syndrome. She was managed conservatively with compression stockings.

  8. Arterio-Venous Anastomoses and Thermoregulation (Arterio-Veneuze Anastomosen en Thermoregulatie)

    Science.gov (United States)

    1991-08-22

    in the skin of the nose, ears and lips. Furthermore, they are found in the nail bed, corpus cavernosum of the penis of the man, ovarium of the woman...diameter of the vessels was a criterion for the existence of an AVA. Enlarged capillaries or preferential channels are thus wrongly seen as AVA. 10 3.3...considerably enlarged . It makes an S-shaped curve and then narrows down to become continuous with a short funnel-shaped vein which opens at right angles, into

  9. A brief clinical case of monitoring of oxygenator performance and patient-machine interdependency during prolonged veno-venous extracorporeal membrane oxygenation.

    Science.gov (United States)

    Belliato, Mirko; Degani, Antonella; Buffa, Antonino; Sciutti, Fabio; Pagani, Michele; Pellegrini, Carlo; Iotti, Giorgio Antonio

    2017-10-01

    Monitoring veno-venous extracorporeal membrane oxygenation (vvECMO) during 76 days of continuous support in a 42-years old patient with end-stage pulmonary disease, listed for double-lung transplantation. Applying a new monitor (Landing ® , Eurosets, Medolla, Italy) and describing how measured and calculated parameters can be used to understand the variable interdependency between artificial membrane lung (ML) and patient native lung (NL). During vvECMO, in order to understand how the respiratory function is shared between ML and NL, ideally we should obtain data about oxygen transfer and CO 2 removal, both by ML and NL. Measurements for NL can be made on the mechanical ventilator. Measurements for ML are typically made from gas analysis on blood samples drawn from the ECMO system before and after the oxygenator, and therefore are non-continuous. Differently, the Landing monitor provides a continuous measurement of the oxygen transfer from the ML, combined with hemoglobin level, saturation of drained blood and saturation of reinfused blood. Moreover, the Landing monitor provides hemodynamics data about circulation through the ECMO system, with blood flow, pre-oxygenator pressure and post-oxygenator pressure. Of note, measurements include the drain negative pressure, whose monitoring may be particularly useful to prevent hemolysis. Real-time monitoring of vvECMO provides data helpful to understand the complex picture of a patient with severely damaged lungs on one side and an artificial lung on the other side. Data from vvECMO monitoring may help to adapt the settings of both mechanical ventilator and vvECMO. Data about oxygen transfer by the oxygenator are important to evaluate the performance of the device and may help to avoid unnecessary replacements, thus reducing risks and costs.

  10. An algorithm for sensing venous oxygenation using ultrasound-modulated light enhanced by microbubbles

    Science.gov (United States)

    Honeysett, Jack E.; Stride, Eleanor; Deng, Jing; Leung, Terence S.

    2012-02-01

    Near-infrared spectroscopy (NIRS) can provide an estimate of the mean oxygen saturation in tissue. This technique is limited by optical scattering, which reduces the spatial resolution of the measurement, and by absorption, which makes the measurement insensitive to oxygenation changes in larger deep blood vessels relative to that in the superficial tissue. Acousto-optic (AO) techniques which combine focused ultrasound (US) with diffuse light have been shown to improve the spatial resolution as a result of US-modulation of the light signal, however this technique still suffers from low signal-to-noise when detecting a signal from regions of high optical absorption. Combining an US contrast agent with this hybrid technique has been proposed to amplify an AO signal. Microbubbles are a clinical contrast agent used in diagnostic US for their ability to resonate in a sound field: in this work we also make use of their optical scattering properties (modelled using Mie theory). A perturbation Monte Carlo (pMC) model of light transport in a highly absorbing blood vessel containing microbubbles surrounded by tissue is used to calculate the AO signal detected on the top surface of the tissue. An algorithm based on the modified Beer-Lambert law is derived which expresses intravenous oxygen saturation in terms of an AO signal. This is used to determine the oxygen saturation in the blood vessel from a dual wavelength microbubble-contrast AO measurement. Applying this algorithm to the simulation data shows that the venous oxygen saturation is accurately recovered, and this measurement is robust to changes in the oxygenation of the superficial tissue layer.

  11. [The use of labelled albumin microspheres in the study of arteriovenous shunting in varicosities of the lower limbs (author's transl)].

    Science.gov (United States)

    Serise, J M; Le Héron, D; Le Héron, G; Bonnet, A; Busquet, J; Basse-Cathalinat, B; Tingaud, R

    1982-01-01

    The greater proportion of oxygen in the blood circulating in veins of the lower limbs bought to attention the possibility of pre-capillary arteriovenous shunting. The intra-arteriel injection of Technetium labelled serum albumin microspheres enables one to quantify arteriovenous shunts greater than 25 microns. The authors made a comparative study of arterio-venous shunting by blood gases analysis and isotopic techniques in twenty patients. The results seem to deny the existence of arteriovenous shunts in the genesis of essential varicose veins in the lower limb.

  12. Disconnection of Cobe SMARxT tubing from the venous outlet of the Terumo Capiox SX25RX oxygenator during cardiopulmonary bypass.

    Science.gov (United States)

    Ottens, Jane; Baker, Robert A; Sanderson, Andrew J; Newland, Richard F

    2010-06-01

    The use of surface modified, biocompatible tubing in cardiopulmonary bypass has been reported to decrease the inflammatory responses caused by blood contact with the non endothelial surface of poly vinyl chloride (PVC) tubing. The combination of advances in biocompatible tubing and increased affordability resulted in a change to our cardiopulmonary bypass circuit, with the Terumo Capiox SX25 oxygenator and Cobe PVC tubing being replaced with a Terumo Capiox SX25RX (with X coating) and Cobe SMARxT tubing. Prior to the introduction of the coated oxygenator, no connection problems had been evident. One unrelated disconnection involving coated tubing was reported in June 2005 to the Australian and New Zealand College of Perfusionists Perfusion Incident Reporting System. At this time we revised all of our set up protocols and the recommended actions from manufacturers. We further report three separate incidents of pump boot disconnection from the venous reservoir outlet of the oxygenator during bypass (that occurred within a 13-month period), and an outline of immediate and prospective evaluation of the probable cause. We propose that SMARxT 3/8" x 3/32" tubing should not be used on the venous outlet connector of Terumo Capiox SX25RX oxygenators. It appears as though the design of the outlet combined with the properties of SMARxT tubing may contribute to the disconnection.

  13. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  14. Right ventricular oxygen supply/demand balance in exercising dogs.

    Science.gov (United States)

    Hart, B J; Bian, X; Gwirtz, P A; Setty, S; Downey, H F

    2001-08-01

    This is the first investigation of right ventricular (RV) myocardial oxygen supply/demand balance in a conscious animal. A novel technique developed in our laboratory was used to collect right coronary (RC) venous blood samples from seven instrumented, conscious dogs at rest and during graded treadmill exercise. Contributions of the RV oxygen extraction reserve and the RC flow reserve to exercise-induced increases in RV oxygen demand were measured. Strenuous exercise caused a 269% increase in RV oxygen consumption. Expanded arteriovenous oxygen content difference (A-V(Delta)O2) provided 58% of this increase in oxygen demand, and increased RC blood flow (RCBF) provided 42%. At less strenuous exercise, expanded A-V(Delta)O2 provided 60-80% of the required oxygen, and increases in RCBF were small and driven by increased aortic pressure. RC resistance fell only at strenuous exercise after the extraction reserve had been mobilized. Thus RC resistance was unaffected by large decreases in RC venous PO2 until an apparent threshold at 20 mmHg was reached. Comparisons of RV findings with published left ventricular data from exercising dogs demonstrated that increased O2 demand of the left ventricle is met primarily by increasing coronary flow, whereas increased O2 extraction makes a greater contribution to RV O2 supply.

  15. Sympathetic reflex control of resistance in collateral arteries in the lower extremities in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Agerskov, K; Tønnesen, K H

    1982-01-01

    The vascular response in the lower extremities to 40 degrees head-up tilt was studied in 5 patients with occlusion of the superficial femoral artery and maturity onset diabetes mellitus with symptoms suggesting autonomic neuropathy. The pressure measurements were performed via catheters placed...... in the brachial artery, femoral artery and vein and popliteal artery and vein. Relative blood flow was calculated as the relative change in arterio-venous oxygen saturation. Absolute blood flow in the common femoral artery was measured by an indicator dilution technique. Resistance of the collateral arteries...

  16. Large arteriolar component of oxygen delivery implies a safe margin of oxygen supply to cerebral tissue.

    Science.gov (United States)

    Sakadžić, Sava; Mandeville, Emiri T; Gagnon, Louis; Musacchia, Joseph J; Yaseen, Mohammad A; Yucel, Meryem A; Lefebvre, Joel; Lesage, Frédéric; Dale, Anders M; Eikermann-Haerter, Katharina; Ayata, Cenk; Srinivasan, Vivek J; Lo, Eng H; Devor, Anna; Boas, David A

    2014-12-08

    What is the organization of cerebral microvascular oxygenation and morphology that allows adequate tissue oxygenation at different activity levels? We address this question in the mouse cerebral cortex using microscopic imaging of intravascular O2 partial pressure and blood flow combined with numerical modelling. Here we show that parenchymal arterioles are responsible for 50% of the extracted O2 at baseline activity, and the majority of the remaining O2 exchange takes place within the first few capillary branches. Most capillaries release little O2 at baseline acting as an O2 reserve that is recruited during increased neuronal activity or decreased blood flow. Our results challenge the common perception that capillaries are the major site of O2 delivery to cerebral tissue. The understanding of oxygenation distribution along arterio-capillary paths may have profound implications for the interpretation of blood-oxygen-level dependent (BOLD) contrast in functional magnetic resonance imaging and for evaluating microvascular O2 delivery capacity to support cerebral tissue in disease.

  17. Arterio-venous concentration difference of [51Cr]EDTA after a single injection in man. Significance of renal function and local blood flow

    DEFF Research Database (Denmark)

    Rehling, M; Hyldstrup, L; Henriksen, Jens Henrik Sahl

    1989-01-01

    , whereas the difference was very sensitive to even small changes in forearm blood flow within the physiological range. For measurement of renal plasma clearance it is recommended to use one long period: from the time of injection until 300 min p.i. or longer. If the clearance period is too short, the use...... introduced in the measurement of renal plasma clearance and total plasma clearance by using venous blood samples instead of arterial. In 13 patients with GFR ranging from 29 to 150 ml min-1, Ca was higher than Cv immediately after the injection. After mean 38 min (range 12-82 min) the two curves crossed...... of venous samples will overestimate the true renal clearance. Plasma clearance determined by venous and arterial blood samples does not differ significantly as long as the concentration is followed from the time of injection and a long period is applied. When simplified plasma clearance techniques are used...

  18. Disconnection of Cobe SMARxT® Tubing from the Venous Outlet of the Terumo Capiox® SX25RX Oxygenator During Cardiopulmonary Bypass

    Science.gov (United States)

    Ottens, Jane; Baker, Robert A.; Sanderson, Andrew J.; Newland, Richard F.

    2010-01-01

    Abstract: The use of surface modified, biocompatible tubing in cardiopulmonary bypass has been reported to decrease the inflammatory responses caused by blood contact with the non endothelial surface of poly vinyl chloride (PVC) tubing. The combination of advances in biocompatible tubing and increased affordability resulted in a change to our cardiopulmonary bypass circuit, with the Terumo Capiox® SX25 oxygenator and Cobe PVC tubing being replaced with a Terumo Capiox® SX25RX (with X coating) and Cobe SMARxT® tubing. Prior to the introduction of the coated oxygenator, no connection problems had been evident. One unrelated disconnection involving coated tubing was reported in June 2005 to the Australian and New Zealand College of Perfusionists Perfusion Incident Reporting System. At this time we revised all of our set up protocols and the recommended actions from manufacturers. We further report three separate incidents of pump boot disconnection from the venous reservoir outlet of the oxygenator during bypass (that occurred within a 13-month period), and an outline of immediate and prospective evaluation of the probable cause. We propose that SMARxT® 3/8″ × 3/32″ tubing should not be used on the venous outlet connector of Terumo Capiox® SX25RX oxygenators. It appears as though the design of the outlet combined with the properties of SMARxT® tubing may contribute to the disconnection. PMID:20648902

  19. The role of central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference as a goal and prognosis of sepsis treatment.

    Science.gov (United States)

    Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon

    2016-12-01

    The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Age-related changes in oxygen and nutrient uptake by hindquarters in newborn pigs during cold-induced shivering.

    Science.gov (United States)

    Lossec, G; Lebreton, Y; Hulin, J C; Fillaut, M; Herpin, P

    1998-11-01

    Newborn pigs rely essentially on shivering thermogenesis in the cold. In order to understand the rapid postnatal enhancement of thermogenic capacities in piglets, the oxygen and nutrient uptake of hindquarters was measured in vivo in 1- (n = 6) and 5-day-old (n = 6) animals at thermal neutrality and during cold exposure. The hindquarters were considered to represent a skeletal muscle compartment. Indirect calorimetry and arterio-venous techniques were used. The cold challenge (23 C at 1 day old and 15 C at 5 days old for 90 min) induced a similar increase (+90 %) in regulatory heat production at both ages. Hindquarters blood flow was higher at 5 days than 1 day old at thermal neutrality (26 +/- 3 vs. 17 +/- 1 ml min-1 (100 g hindquarters)-1) and its increase in the cold was much more marked (+65 % at 5 days old vs. +25 % at 1 day old). Oxygen extraction by the hindquarters rose from 30-35 % at thermal neutrality to 65-70 % in the cold at both ages. The calculated contribution of skeletal muscle to total oxygen consumption averaged 34-40 % at thermal neutrality and 50-64 % in the cold and skeletal muscle was the major contributor to regulatory thermogenesis. Based on hindquarters glucose uptake and lactate release, carbohydrate appeared to be an important fuel for shivering. However, net uptake of fatty acids increased progressively during cold exposure at 5 days old. The enhancement in muscular blood supply and fatty acid utilization during shivering is probably related to the postnatal improvement in the thermoregulatory response of the piglet.

  1. Noninvasive measurement of cerebral venous oxygenation in neonates with a multi-wavelength, fiber-coupled laser diode optoacoustic system

    Science.gov (United States)

    Herrmann, Stephen; Petrov, Irene Y.; Petrov, Yuriy; Fonseca, Rafael A.; Richardson, C. Joan; Shanina, Ekaterina; Prough, Donald S.; Esenaliev, Rinat O.

    2018-03-01

    Noninvasive measurement of cerebral venous oxygenation in neonates could provide critical information for clinicians such as cerebral hypoxia without the risks involved with invasive catheterization. Evaluation of cerebral hypoxia is important in many clinical settings such as hypoxic-ischemic encephalopathy, perfusion monitoring in cardiovascular surgery or in traumatic brain injury. By probing the superior sagittal sinus (SSS), a large central cerebral vein, we can obtain stable signals with our recently developed multi-wavelength, fiber-coupled laser diode optoacoustic system for measurement of SSS blood oxygenation. The neonatal SSS oxygenation was measured in the reflection mode through open anterior and posterior fontanelles without obscuration by the overlying calvarium. In the transmission mode it was measured through the skull in the occipital area. Our device is lightweight, easily maneuverable, and user friendly for physicians. We monitored the SSS oxygenation in neonates admitted to the Neonatal Intensive Care Unit (NICU) of UTMB with varying gestation, birth weight and clinical histories to identify normal range and difference between neonates with and without risk factors for cerebral hypoxia.

  2. Treatment of portal venous gas embolism with hyperbaric oxygen after accidental ingestion of hydrogen peroxide: a case report and review of the literature.

    Science.gov (United States)

    Papafragkou, Sotirios; Gasparyan, Anna; Batista, Richard; Scott, Paul

    2012-07-01

    It is well known that hydrogen peroxide ingestion can cause gas embolism. To report a case illustrating that the definitive, most effective treatment for gas embolism is hyperbaric oxygen therapy. We present a case of a woman who presented to the Emergency Department with acute abdominal pain after an accidental ingestion of concentrated hydrogen peroxide. Complete recovery from her symptoms occurred quickly with hyperbaric oxygen therapy. This is a case report of the successful use of hyperbaric oxygen therapy to treat portal venous gas embolism caused by hydrogen peroxide ingestion. Hyperbaric oxygen therapy can be considered for the treatment of symptomatic hydrogen peroxide ingestion. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Induced venous pooling and cardiorespiratory responses to exercise after bed rest

    Science.gov (United States)

    Convertino, V. A.; Sandler, H.; Webb, P.; Annis, J. F.

    1982-01-01

    Venous pooling induced by a specially constructed garment is investigated as a possible means for reversing the reduction in maximal oxygen uptake regularly observed following bed rest. Experiments involved a 15-day period of bed rest during which four healthy male subjects, while remaining recumbent in bed, received daily 210-min venous pooling treatments from a reverse gradient garment supplying counterpressure to the torso. Results of exercise testing indicate that while maximal oxygen uptake endurance time and plasma volume were reduced and maximal heart rate increased after bed rest in the control group, those parameters remained essentially unchanged for the group undergoing venous pooling treatment. Results demonstrate the importance of fluid shifts and venous pooling within the cardiovascular system in addition to physical activity to the maintenance of cardiovascular conditioning.

  4. Activated carbon oxygen content influence on water and surfactant adsorption.

    Science.gov (United States)

    Pendleton, Phillip; Wu, Sophie Hua; Badalyan, Alexander

    2002-02-15

    This research investigates the adsorption properties of three activated carbons (AC) derived from coconut, coal, and wood origin. Each carbon demonstrates different levels of resistance to 2 M NaOH treatment. The coconut AC offers the greatest and wood AC the least resistance. The influence of base treatment is mapped in terms of its effects on specific surface area, micropore volume, water adsorption, and dodecanoic acid adsorption from both water and 2 M NaOH solution. A linear relationship exists between the number of water molecules adsorbed at the B-point of the water adsorption isotherm and the oxygen content determined from elemental analysis. Surfactant adsorption isotherms from water and 2 M NaOH indicate that the AC oxygen content effects a greater dependence on affinity for surfactant than specific surface area and micropore volume. We show a linear relationship between the plateau amount of surfactant adsorbed and the AC oxygen content in both water and NaOH phases. The higher the AC oxygen content, the lower the amount of surfactant adsorbed. In contrast, no obvious relationship could be drawn between the surfactant amount adsorbed and the surface area.

  5. Assistance protocol for venous ulcers patients: validation of contents

    Directory of Open Access Journals (Sweden)

    Daniele Vieira Dantas

    2013-07-01

    Full Text Available Venous ulcers require complex treatment and are responsible for significant morbidity and mortality rates. This study aims at identifying aspects validated by the jury for the preparation of an assistance protocol for venous ulcer sufferers. It is a descriptive and quantitative research, with 39 professionals (30 nurses, 7 doctors and two physiotherapists, held at the Onofre Lopes University Hospital, between April and July/2010. Data collection began through a questionnaire checklist. Analysis was performed through Statistical Package for Social Science 15.0, assessing compliance with guidelines. Results were the compositional aspects of the protocol: assessment of patient and lesion history/documentation, wound care/perilesional skin, dressing suggestion, use of antibiotics and pain treatment, surgical treatment/medication, improving venous return and relapse prevention, patient referral, professional training and referral/counter-referral. It was concluded that to compose the protocol, aspects related to diagnosis, treatment and injury prevention must be considered.

  6. The effects of arterial carbon dioxide partial pressure and sevoflurane on capillary venous cerebral blood flow and oxygen saturation during craniotomy.

    Science.gov (United States)

    Klein, Klaus Ulrich; Glaser, Martin; Reisch, Robert; Tresch, Achim; Werner, Christian; Engelhard, Kristin

    2009-07-01

    Intraoperative routine monitoring of cerebral blood flow and oxygenation remains a technological challenge. Using the physiological principle of carbon dioxide reactivity of cerebral vasculature, we investigated a recently developed neuromonitoring device (oxygen-to-see, O2C device) for simultaneous measurements of regional cerebral blood flow (rvCBF), blood flow velocity (rvVelo), oxygen saturation (srvO2), and hemoglobin amount (rvHb) at the capillary venous level in patients subjected to craniotomy. Twenty-six neurosurgical patients were randomly assigned to anesthesia with 1.4% or 2.0% sevoflurane end-tidal concentration. After craniotomy, a fiberoptic probe was applied on a macroscopically healthy surface of cerebral tissue next to the site of surgery. Simultaneous measurements in 2 and 8 mm cerebral depth were performed in each patient during lower (35 mm Hg) and higher (45 mm Hg) levels (random order) of arterial carbon dioxide partial pressure (PaCO2). The principle of these measurements relies on the combination of laser-Doppler flowmetry (rvCBF, rvVelo) and photo-spectrometry (srvO2, rvHb). Linear models were fitted to test changes of end points (rvCBF, rvVelo, srvO2, rvHb) in response to lower and higher levels of PaCO2, 1.4% and 2.0% sevoflurane end-tidal concentration, and 2 and 8 mm cerebral depth. RvCBF and rvVelo were elevated by PaCO2 independent of sevoflurane concentration in 2 and 8 mm depth of cerebral tissue (P oxygen was decreased by elevated PaCO2. Unchanged levels of rvHb signify that there was no blood loss during measurements. Data suggest that the device allows detection of local changes in blood flow and oxygen saturation in response to different PaCO2 levels in predominant venous cerebral microvessels.

  7. Combining central venous-to-arterial partial pressure of carbon dioxide difference and central venous oxygen saturation to guide resuscitation in septic shock.

    Science.gov (United States)

    Du, Wei; Liu, Da-Wei; Wang, Xiao-Ting; Long, Yun; Chai, Wen-Zhao; Zhou, Xiang; Rui, Xi

    2013-12-01

    Central venous oxygen saturation (Scvo2) is a useful therapeutic target when treating septic shock. We hypothesized that combining Scvo2 and central venous-to-arterial partial pressure of carbon dioxide difference (△Pco2) may provide additional information about survival. We performed a retrospective analysis of 172 patients treated for septic shock. All patients were treated using goal-directed therapy to achieve Scvo2 ≥ 70%. After 6 hours of treatment, we divided patients into 4 groups based on Scvo2 (<70% or ≥ 70%) and △Pco2 (<6 mm Hg or ≥ 6 mm Hg). Overall, 28-day mortality was 35.5%. For patients in whom the Scvo2 target was not achieved at 6 hours, mortality was 50.0%, compared with 29.5% in those in whom Scvo2 exceeded 70% (P = .009). In patients with Scvo2 ≥ 70%, mortality was lower if △Pco2 was <6 mm Hg than if △Pco2 was ≥ 6 mm Hg (56.1% vs 16.1%, respectively; P < .001) and 6-hour lactate clearance was superior (0.01 ± 0.61 vs 0.21 ± 0.31, respectively; P = .016). The combination of Scvo2 and △Pco2 appears to predict outcome in critically ill patients resuscitated from septic shock better than Scvo2 alone. Patients who meet both targets appear to clear lactate more efficiently. © 2013.

  8. Occurence of stationary waves in angiography of peripheral vessels

    International Nuclear Information System (INIS)

    Boettcher, H.D.; Schmilowski, G.M.; Haverkamp, U.; Wagner, W.

    1983-01-01

    Among 229 angiographies of periphal vascular occlusions performed in 1981 and during the first half of 1982 at the Radiologic Clinic of Muenster University, stationary waves developed in one case in the vascular band before the occlusion. This phenomenon can be a pointer towards assuming that over long distances before the occlusion there is no satisfactory outflow provided for by collaterals, intact arterio-arterial or arterio-venous connections. (orig.) [de

  9. Retinal Oxygen Delivery and Metabolism in Healthy and Sickle Cell Retinopathy Subjects.

    Science.gov (United States)

    Shahidi, Mahnaz; Felder, Anthony E; Tan, Ou; Blair, Norman P; Huang, David

    2018-04-01

    Reduction in inner retinal oxygen delivery (DO2) can cause retinal hypoxia and impair inner retinal oxygen metabolism (MO2), leading to vision loss. The purpose of the current study was to establish measurements of DO2 and MO2 in healthy subjects and test the hypothesis that DO2 and MO2 are reduced in sickle cell retinopathy (SCR) subjects. Dual wavelength retinal oximetry and Doppler optical coherence tomography were performed in 12 healthy control and 12 SCR subjects. Images were analyzed to measure retinal arterial and venous oxygen content (O2A and O2V), venous diameter (DV), and total retinal blood flow (TRBF). Retinal arteriovenous oxygen content difference (O2AV), DO2, MO2, and oxygen extraction fraction (OEF) were calculated according to the following equations: O2AV = O2A - O2V; DO2 = TRBF * O2A; MO2 = TRBF * O2AV; OEF = MO2/DO2. Retinal DV and TRBF were higher in the SCR group as compared to the control group, whereas, O2A, O2V, and O2AV were lower in SCR group as compared to the control group. DO2, MO2, and OEF were not significantly different between control and SCR groups. MO2 and DO2 were linearly related, such that higher MO2 was associated with higher DO2. There was an inverse relationship between TRBF and OEF, such that lower TRBF was associated with higher OEF. Increased blood flow compensated for decreased oxygen content, thereby maintaining DO2, MO2, and OEF at predominately lower stages of SCR. Quantitative assessment of these parameters has the potential to advance knowledge and improve diagnostic evaluation of retinal ischemic conditions.

  10. Resuscitation by hyperbaric exposure from a venous gas emboli following laparoscopic surgery

    DEFF Research Database (Denmark)

    Kjeld, Thomas; Hansen, Egon G; Holler, Nana G

    2012-01-01

    Venous gas embolism is common after laparoscopic surgery but is only rarely of clinical relevance. We present a 52 year old woman undergoing laparoscopic treatment for liver cysts, who also underwent cholecystectomy. She was successfully extubated. However, after a few minutes she developed cardiac......, could have contributed to the formation of the intravascular gas emboli. We conclude that persistent resuscitation followed by hyperbaric oxygen treatment after venous gas emboli contributed to the elimination of intravascular bubbles and the favourable outcome for the patient....... arrest due to a venous carbon dioxide (CO2) embolism as identified by transthoracic echocardiography and aspiration of approximately 7 ml of gas from a central venous catheter. She was resuscitated and subsequently treated with hyperbaric oxygen to reduce the size of remaining gas bubbles. Subsequently...

  11. Compression therapies for chronic venous leg ulcers: interventions and adherence

    Directory of Open Access Journals (Sweden)

    Latz CA

    2015-01-01

    Full Text Available Christopher A Latz,1 Kellie R Brown,2 Ruth L Bush11Texas A&M Health Science Center College of Medicine, Bryan, TX, USA; 2Medical College of Wisconsin, Milwaukee, WI, USAAbstract: Compression therapy has been the mainstay for the treatment of lower extremity edema, venous insufficiency, and particularly, venous ulcerative disease. Though modern surgical treatments exist, none are completely effective without good compressive options to allow for decreased swelling and better oxygenation of damaged tissues. This review article will describe the pathophysiology and presentation of lower extremity venous ulcerations, as well as current options for compression therapy. The benefits, along with the major pitfall of nonadherence, will also be discussed.Keywords: venous disease, chronic venous insufficiency, venous ulceration

  12. Systematic review and meta-analysis of complications and mortality of veno-venous extracorporeal membrane oxygenation for refractory acute respiratory distress syndrome.

    Science.gov (United States)

    Vaquer, Sergi; de Haro, Candelaria; Peruga, Paula; Oliva, Joan Carles; Artigas, Antonio

    2017-12-01

    Veno-venous extracorporeal membrane oxygenation (ECMO) for refractory acute respiratory distress syndrome (ARDS) is a rapidly expanding technique. We performed a systematic review and meta-analysis of the most recent literature to analyse complications and hospital mortality associated with this technique. Using the PRISMA guidelines for systematic reviews and meta-analysis, MEDLINE and EMBASE were systematically searched for studies reporting complications and hospital mortality of adult patients receiving veno-venous ECMO for severe and refractory ARDS. Studies were screened for low bias risk and assessed for study size effect. Meta-analytic pooled estimation of study variables was performed using a weighted random effects model for study size. Models with potential moderators were explored using random effects meta-regression. Twelve studies fulfilled inclusion criteria, representing a population of 1042 patients with refractory ARDS. Pooled mortality at hospital discharge was 37.7% (CI 95% = 31.8-44.1; I 2  = 74.2%). Adjusted mortality including one imputable missing study was 39.3% (CI 95% = 33.1-45.9). Meta-regression model combining patient age, year of study realization, mechanical ventilation (MV) days and prone positioning before veno-venous ECMO was associated with hospital mortality (p < 0.001; R 2  = 0.80). Patient age (b = 0.053; p = 0.01) and maximum cannula size during treatment (b = -0.075; p = 0.008) were also independently associated with mortality. Studies reporting H1N1 patients presented inferior hospital mortality (24.8 vs 40.6%; p = 0.027). Complication rate was 40.2% (CI 95% = 25.8-56.5), being bleeding the most frequent 29.3% (CI 95% = 20.8-39.6). Mortality due to complications was 6.9% (CI 95% = 4.1-11.2). Mechanical complications were present in 10.9% of cases (CI 95% = 4.7-23.5), being oxygenator failure the most prevalent (12.8%; CI 95% = 7.1-21.7). Despite initial severity, significant portion of patients

  13. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  14. Adsorption of ionizable organic contaminants on multi-walled carbon nanotubes with different oxygen contents

    International Nuclear Information System (INIS)

    Li Xiaona; Zhao Huimin; Quan Xie; Chen Shuo; Zhang Yaobin; Yu Hongtao

    2011-01-01

    Multi-walled carbon nanotubes (MWNTs), which are considered to be promising candidates for the adsorption of toxic organics, are released into aqueous environment with their increasing production and application. In this study, the adsorption behaviors of five structurally related ionizable organic contaminants namely perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorooctanesulfonamide (PFOSA), 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-n-nonylphenol (4-NP) onto MWNTs with different oxygen contents (3.84-22.85%) were investigated. The adsorption kinetics was investigated and simulated with pseudo-second-order model. The adsorption isotherms were found to be fitted with Freundlich model and influenced by both the properties of organic chemicals and the oxygen contents of MWNTs. As adsorption capacity decreases dramatically with the increasing of oxygen contents, the MWNTs with the lowest oxygen contents possess the highest adsorption capacity among four MWNTs. For the MWNTs with the oxygen contents of 3.84%, the adsorption affinity related with hydrophobic interaction and π-electron polarizability decreased in the order of 4-NP > PFOSA > PFOS > 2,4-D > PFOA. Furthermore, the adsorption characters of five contaminants were affected by solution pH and solute pK a considering electrostatic repulse force and hydrogen bonding, which showed the adsorption of MWNTs with lower oxygen content is much sensitive to solution chemistry.

  15. Determination of oxygen content in steel using activation analysis with 14 MeV neutron

    International Nuclear Information System (INIS)

    Calado, C.E.

    1978-01-01

    In the quantitative analysis of oxygen in steel by fast neutron activation analysis the oxygen content is evaluated from the measured activity of 16 N produced. Steel s mples are irradiated in 14 MeV neutron flux. After irradiation the samples are pneumatically transfered to the counting terminal where activity is measured. Oxygen concentrations, are obtained by comparison with standards of specified oxygen content [pt

  16. Hydrogen peroxide ingestion associated with portal venous gas and treatment with hyperbaric oxygen: a case series and review of the literature.

    Science.gov (United States)

    French, Loren Keith; Horowitz, B Zane; McKeown, Nathanael J

    2010-07-01

    Ingestion of concentrated hydrogen peroxide (H(2)O(2)) has been associated with venous and arterial gas embolic events, hemorrhagic gastritis, gastrointestinal bleeding, shock, and death. Although H(2)O(2) is generally considered a benign ingestion in low concentrations, case reports have described serious toxicity following high concentration exposures. Hyperbaric oxygen (HBO) has been used with success in managing patients suffering from gas embolism with and without manifestations of ischemia. Poison center records were searched from July 1999 to January 2010 for patients with H(2)O(2) exposure and HBO treatment. Cases were reviewed for the concentration of H(2)O(2), symptoms, CT scan findings of portal gas embolism, HBO treatment, and outcome. RESULTS; Eleven cases of portal gas embolism were found. Ages ranged from 4 to 89 years. All but one ingestion was accidental in nature. In 10 cases 35% H(2)O(2) was ingested and in 1 case 12% H(2)O(2) was ingested. All abdominal CT scans demonstrated portal venous gas embolism in all cases. Hyperbaric treatment was successful in completely resolving all portal venous gas bubbles in nine patients (80%) and nearly resolving them in two others. Ten patients were able to be discharged home within 1 day, and one patient had a 3.5-day length of stay. HBO was successful in resolving portal venous gas embolism from accidental concentrated H(2)O(2) ingestions.

  17. The effect of oxygen content during an initial sustained inflation on heart rate in asphyxiated near-term lambs.

    Science.gov (United States)

    Sobotka, K S; Ong, T; Polglase, G R; Crossley, K J; Moss, T J M; Hooper, S B

    2015-07-01

    At birth, an initial sustained inflation (SI) uniformly aerates the lungs, increases arterial oxygenation and rapidly improves circulatory recovery in asphyxiated newborns. We hypothesised that lung aeration, in the absence of an increase in arterial oxygenation, can increase heart rate (HR) in asphyxiated near-term lambs. Lambs were delivered and instrumented at 139±2 days of gestation. Asphyxia was induced by umbilical cord clamping and then delaying the onset of ventilation until mean carotid arterial pressures (CAPs) had decreased <20 mm Hg. Lambs then received a single 30-s SI using nitrogen (N2; n=6), 5% oxygen (O2; n=6), 21% O2 (n=6) or 100% O2 (n=6) followed by ventilation in air for 30 min. HR, CAP and pulmonary blood flow (PBF) were continuously recorded. HR and PBF increased more quickly in lambs resuscitated with 100% and 21% O2 than with 5% O2 or N2. HR and PBF recovery in the 5% O2 group was delayed relative to all other oxygen SI groups. HR in 5%, 21% and 100% O2 groups reached 100 bpm before the SI was complete. HR and PBF in the N2 group did not increase until 10 s after the SI was completed and ventilation was initiated with air. CAP tended to increase quicker in all O2 groups than in N2 group. Oxygen content during an SI is important for circulatory recovery in asphyxiated lambs. This increase in HR is likely driven by the increase in PBF and venous return to the heart. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Development of micro-coulometry for measuring oxygen content in copper oxides

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Fujihara, Masaaki; Kambe, Shiro; Ishii, Osamu

    2006-01-01

    A micro-coulometry system was newly developed and employed for measuring the oxygen content in copper oxides using a reduced amount of material. To achieve this reduction in sample size, Ar flow rate, and coulometric current were optimized. When using 5.0 mg of YBa 2 Cu 3 O 6.71 , which is about 1/10 the amount used in conventional coulometry, the oxygen content was successfully determined to be 6.68 ± 0.03, Ar flow rate, and coulometric current were 0.1 l/min, and 1.0 mA, respectively. It was found to be necessary to continue to pass Ar through the solution before coulometry more than ten minutes and during the coulometric measurement. This method will be useful for measuring the oxygen content of oxide samples smaller than 10 mg, i.e. oxide materials produced in small quantities for electronic applications

  19. Automatic Control of Veno-Venous Extracorporeal Lung Assist.

    Science.gov (United States)

    Kopp, Ruedger; Bensberg, Ralf; Stollenwerk, Andre; Arens, Jutta; Grottke, Oliver; Walter, Marian; Rossaint, Rolf

    2016-10-01

    Veno-venous extracorporeal lung assist (ECLA) can provide sufficient gas exchange even in most severe cases of acute respiratory distress syndrome. Commercially available systems are manually controlled, although an automatically controlled ECLA could allow individualized and continuous adaption to clinical requirements. Therefore, we developed a demonstrator with an integrated control algorithm to keep continuously measured peripheral oxygen saturation and partial pressure of carbon dioxide constant by automatically adjusting extracorporeal blood and gas flow. The "SmartECLA" system was tested in six animal experiments with increasing pulmonary hypoventilation and hypoxic inspiratory gas mixture to simulate progressive acute respiratory failure. During a cumulative evaluation time of 32 h for all experiments, automatic ECLA control resulted in a peripheral oxygen saturation ≥90% for 98% of the time with the lowest value of 82% for 15 s. Partial pressure of venous carbon dioxide was between 40 and 49 mm Hg for 97% of the time with no value 49 mm Hg. With decreasing inspiratory oxygen concentration, extracorporeal oxygen uptake increased from 68 ± 25 to 154 ± 34 mL/min (P < 0.05), and reducing respiratory rate resulted in increasing extracorporeal carbon dioxide elimination from 71 ± 37 to 92 ± 37 mL/min (P < 0.05). The "SmartECLA" demonstrator allowed reliable automatic control of the extracorporeal circuit. Proof of concept could be demonstrated for this novel automatically controlled veno-venous ECLA circuit. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Weldability of powder-metallurgy molybdenum with low oxygen content

    International Nuclear Information System (INIS)

    Hiraoka, Yutaka; Okada, Masatoshi

    1987-01-01

    Relationships between the formation of weld pores and the chemical compositions in powder-metallurgy molybdenum were investigated. It is suggested that almost 100% of Ca and Mg form oxides. In contrast, Fe, Ni, Cr and Al, Si only partly form oxides. A powder-metallurgy molybdenum containing less than 84 at.ppm oxygen did not show any large weld pores. The reduction of the oxygen content was achieved by purifying the molybdenum powder. (orig.) [de

  1. Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study

    Science.gov (United States)

    Esenaliev, Rinat O.; Larina, Irina V.; Larin, Kirill V.; Deyo, Donald J.; Motamedi, Massoud; Prough, Donald S.

    2002-08-01

    Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.

  2. [Regional cerebral oxygen saturation as a marker of hemodynamic state following cardiac surgery].

    Science.gov (United States)

    García-Hernández, J A; Aldemira-Liz, A; Martínez-López, A I; Cayuela, A; Charlo-Molina, M T; Cano-Franco, J; Loscertales-Abril, M

    2013-10-01

    Regional cerebral oxygen saturation (rSO₂) is a measure of the general state of perfusion and oxygenation. We aim to analyze the relationship between this and various hemodynamic and respiratory parameters. Forty-three patients, operated on between October 2011 and July 2012, were included in this prospective observational descriptive study. The following parameters were measured: mean arterial pressure, both arterial and central venous oxygen saturation and partial pressures of oxygen and carbon dioxide, and lactate levels. From these parameters, the oxygenation index and the oxygen extraction ratio were calculated. These measurements were studied to evaluate whether rSO₂ correlated significantly with the other parameters. The average age and weight of the patients were 27.3 months and 9.2 kg, respectively. The rSO₂ correlated positively with both central venous oxygen saturation (r=0.73, P 0.4) between the rSO₂ and central venous oxygen saturation, and between the rSO₂ and oxygen extraction ratio. Regional cerebral oxygen saturation correlates well with hemodynamic parameters - mean arterial pressure, venous saturation, and the tissue oxygen extraction. However, it does not correlate with respiratory parameters. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  3. Effect of the oxygen content in solution on the static and cyclic deformation of titanium foams.

    Science.gov (United States)

    Lefebvre, L P; Baril, E; Bureau, M N

    2009-11-01

    It is well known that interstitials affect the mechanical properties of titanium and titanium alloys. Their effects on the fatigue properties of titanium foams have not, however, been documented in the literature. This paper presents the effect of the oxygen content on the static and dynamic compression properties of titanium foams. Increasing the oxygen content from 0.24 to 0.51 wt% O in solution significantly increases the yield strength and reduces the ductility of the foams. However, the fatigue limit is not significantly affected by the oxygen content and falls within the 92 MPa +/- 12 MPa range for all specimens investigated in this study. During cyclic loading, deformation is initially coming from cumulative creep followed by the formation of microcracks. The coalescence of these microcracks is responsible for the rupture of the specimens. Fracture surfaces of the specimens having lower oxygen content show a more ductile aspect than the specimens having higher oxygen content.

  4. Gas exchange kinetics following concentric-eccentric isokinetic arm and leg exercise.

    Science.gov (United States)

    Drescher, U; Mookerjee, S; Steegmanns, A; Knicker, A; Hoffmann, U

    2017-06-01

    To evaluate the effects of exercise velocity (60, 150, 240deg∙s -1 ) and muscle mass (arm vs leg) on changes in gas exchange and arterio-venous oxygen content difference (avDO 2 ) following high-intensity concentric-eccentric isokinetic exercise. Fourteen subjects (26.9±3.1years) performed a 3×20-repetition isokinetic exercise protocol. Recovery beat-to-beat cardiac output (CO) and breath-by-breath gas exchange were recorded to determine post-exercise half-time (t 1/2 ) for oxygen uptake (V˙O 2 pulm), carbon dioxide output (V˙CO 2 pulm), and ventilation (V˙ E ). Significant differences of the t 1/2 values were identified between 60 and 150deg∙s -1 . Significant differences in the t 1/2 values were observed between V˙O 2 pulm and V˙CO 2 pulm and between V˙CO 2 pulm and V˙ E . The time to attain the first avDO 2 -peak showed significant differences between arm and leg exercise. The present study illustrates, that V˙O 2 pulm kinetics are distorted due to non-linear CO dynamics. Therefore, it has to be taken into account, that V˙O 2 pulm may not be a valuable surrogate for muscular oxygen uptake kinetics in the recovery phases. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Effect of oxygen content on deformation mode and corrosion behavior in β-type Ti-Mo alloy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Xiaohua, E-mail: minxiaohua@dlut.edu.cn [School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Bai, Pengfei [School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Emura, Satoshi; Ji, Xin [Research Center for Structural Materials, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Cheng, Congqian; Jiang, Beibei [School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Tsuchiya, Koichi [Research Center for Structural Materials, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan)

    2017-01-27

    This study examined microstructural characteristics and mechanical properties in a β-type Ti-15Mo alloy (mass%) with different oxygen contents, and their corrosion behavior in simulated physiological media. With increasing oxygen content from 0.1–0.5%, lattice parameter of parent β-phase increased from X-ray diffraction profiles, and spots of athermal ω-phase became weak and diffuse through transmission electron microscopy observations. {332}<113> twin density decreased with an increase in oxygen content from 0.1–0.3% based on electron backscattered diffraction analyses, and it became almost zero when further increased oxygen content up to 0.5%. The solute oxygen atoms led to both a transition of {332}<113> twinning to dislocation slip and a suppression of β-phase to ω-phase transformation. Room-temperature tensile testing of this alloy with oxygen content ranging from 0.1–0.5%, revealed that yield strength ranged from 420 MPa to 1180 MPa and that uniform elongation ranged from 47–0.2%. The oxygen-added alloys kept a low elastic modulus obtained from stress-strain curves, and exhibited good corrosion resistance in Ringer's solution from open-circuit potential and potentiodynamic polarization measurements. A desirable balance between mechanical properties and corrosion resistance is obtainable in this alloy as biomaterials through utilizing oxygen to control the deformation mode.

  6. Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites

    Energy Technology Data Exchange (ETDEWEB)

    O’Reilly, Michael K., E-mail: moreilly1@mater.ie; Ryan, David; Sugrue, Gavin; Geoghegan, Tony; Lawler, Leo P.; Farrelly, Cormac T. [Mater Misericordiae University Hospital, Department of Interventional Radiology (Ireland)

    2016-12-15

    PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complications were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.

  7. Correlation between arterial and venous blood gas analysis parameters in patients with acute exacerbation of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Novović Miloš

    2012-01-01

    Full Text Available Introduction. Arterial blood gas (ABG analyses have an important role in the assessment and monitoring of the metabolic and oxygen status of patients with acute exacerbation of chronic obstructive pulmonary disease (COPD. Arterial puncture could have a lot of adverse effects, while sampling of venous blood is simpler and is not so invasive. Objective. The aim of this study was to evaluate whether venous blood gas (VBG values of pH, partial pressure of carbon dioxide (PCO2, partial oxygen pressure (PO2, bicarbonate (HCO3, and venous and arterial blood oxygen saturation (SO2 can reliably predict ABG levels in patients with acute exacerbation of COPD. Methods. Forty-seven patients with a prior diagnosis of COPD were included in this prospective study. The patients with acute exacerbation of this disease were examined at the General Hospital EMS Department in Prijepolje. ABG samples were taken immediately after venous sampling, and both were analyzed. Results. The Pearson correlation coefficients between arterial and venous parameters were 0.828, 0.877, 0.599, 0.896 and 0.312 for pH, PCO2, PO2, HCO3 and SO2, respectively. The statistically significant correlation between arterial and venous pH, PCO2 and HCO3, values was found in patients with acute exacerbation of COPD (p<0.001. Conclusion. When we cannot provide arterial blood for analysis, venous values of the pH, Pv,CO2 and HCO3 parameters can be an alternative to their arterial equivalents in the interpretation of the metabolic status in patients with acute exacerbation of COPD, while the values of venous Pv,O2 and Sv,O2 cannot be used as predictors in the assessment of oxygen status of such patients.

  8. Epidural venous stasis in spinal stenosis

    International Nuclear Information System (INIS)

    Kaiser, M.C.; Capesius, P.; Poos, D.; Gratia, G.; Roilgen, A.; Sandt, G.

    1984-01-01

    Computed tomography permits reliable demonstration of the spinal canal and its contents. Measurements of the sagittal diameter of the bony canal do not take into consideration size, shape and state of intraspinal soft tissue structures, i.e. the thecal sac and its own contents, epidural fat and blood circulation pattern. Three particularly illustrative cases were selected in which obvious epidural venous engorgement was visualized in association with spinal stenosis. The authors think that epidural venous stasis occuring in segmental spinal stenosis is a CT sign of clinically significant narrowing of the neural canal. Accurate recognition of the type of lumbar stenosis together with epidural blood flow alterations permits a better understanding of the existing lesions. Thus, a more precise and specific surgical approach is possible. (orig.)

  9. Intra-arterial digital subtraction angiography (IA-DSA) with carbon dioxide

    International Nuclear Information System (INIS)

    Takeda, Toshiaki; Ido, Kunio; Yuasa, Yuji

    1988-01-01

    Intra-Arterial Digital Subtraction Angiography (IA-DSA) with Carbon Dioxide (CO 2 ) was performed on 41 patients mainly with liver or renal diseases, and its angiographic manifestation was compared with that of conventional angiography. Although the image quality of the arterial or capillary phase was inferior to that of conventional angiography with iodinated contrast media, the detectablity of arterio-venous shunting was excellent. In fact, DSA with CO 2 revealed the presence of A-V (A-P) shunt in 26 patients (26/41:63.4 % HCC, 13/15:86.7% metastatic liver tumor, 2/3:66.7 % RCC, 1/5:20 %). On the other hand, conventional angiography was able to show in only 5 cases. DSA with CO 2 will become an effective method for detecting minute arterio-venous shunting which can not be demonstrated with conventional angiography. (author)

  10. Validation of a novel venous duplex ultrasound objective structured assessment of technical skills for the assessment of venous reflux.

    Science.gov (United States)

    Jaffer, Usman; Normahani, Pasha; Lackenby, Kimberly; Aslam, Mohammed; Standfield, Nigel J

    2015-01-01

    Duplex ultrasound measurement of reflux time is central to the diagnosis of venous incompetence. We have developed an assessment tool for Duplex measurement of venous reflux for both simulator and patient-based training. A novel assessment tool, Venous Duplex Ultrasound Assessment of Technical Skills (V-DUOSATS), was developed. A modified DUOSATS was used for simulator training. Participants of varying skill level were invited to viewed an instructional video and were allowed ample time to familiarize with the Duplex equipment. Attempts made by the participants were recorded and independently assessed by 3 expert assessors and 5 novice assessors using the modified V-DUOSATS. "Global" assessment was also done by expert assessors on a 4-point Likert scale. Content, construct, and concurrent validities as well as reliability were evaluated. Content and construct validity as well as reliability were demonstrated. Receiver operator characteristic analysis-established cut points of 19/22 and 21/30 were most appropriate for simulator and patient-based assessment, respectively. We have validated a novel assessment tool for Duplex venous reflux measurement. Further work is required to establish transference validity of simulator training to improve skill in scanning patients. We have developed and validated V-DUOSATS for simulator training. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  11. Characteristics of slowly cooled Zr-Al-Cu-Ni bulk samples with different oxygen content

    International Nuclear Information System (INIS)

    Gebert, A.; Eckert, J.; Bauer, H.-D.; Schultz, L.

    1998-01-01

    Bulk samples of the glass-forming Zr 65 Al 7.5 Cu 17.5 Ni 10 and Zr 55 Al 10 Cu 30 Ni 5 alloys with 3 mm diameter were prepared by die casting into a copper mould. The oxygen content of the samples was varied between 0.26 at.% and 0.73 at.% by adjusting the oxygen partial pressure in the argon atmosphere upon casting. Characterization of the microstructure of as-cast samples and of specimens continuously heated to 873 K was carried out by X-ray diffraction (XRD), optical microscopy (OM) and transmission electron microscopy (TEM). Thermal stability was investigated by constant-rate differential scanning calorimetry (DSC). The phase formation and the thermal stability of the slowly cooled zirconium-based bulk samples are essentially influenced by the oxygen content of the material. Furthermore, the sensitivity to oxygen depends on the composition of the alloy. In bulk Zr 65 Al 7.5 Cu 17.5 Ni 10 samples only small oxygen traces induce nucleation and crystal growth during slow cooling whereas Zr 55 Al 10 Cu 30 Ni 5 samples are completely amorphous for all oxygen contents investigated. The processes of the oxygen-induced phase formation are discussed in detail also with respect to the results obtained for the heat treated samples. With increasing oxygen content the thermal stability deteriorates, as it is obvious from a diminution of the supercooled liquid region (ΔT x = T x - T g ) which is mainly due to a reduction of the crystallization temperature T x . Furthermore, the thermal behaviour of Zr 65 Al 7.5 Cu 17.5 Ni 10 and Zr 55 Al 10 Cu 30 Ni 5 reveals significant differences. (orig.)

  12. Analysis of Arterial and Venous Blood Gases in Healthy Gyr Falcons ( Falco rusticolus ) Under Anesthesia.

    Science.gov (United States)

    Raghav, Raj; Middleton, Rachael; BSc, Rinshiya Ahamed; Arjunan, Raji; Caliendo, Valentina

    2015-12-01

    Arterial and venous blood gas analysis is useful in the assessment of tissue oxygenation and ventilation and in diagnosis of metabolic and respiratory derangements. It can be performed with a relatively small volume of blood in avian patients under emergency situations. Arterial and venous blood gas analysis was performed in 30 healthy gyr falcons ( Falco rusticolus ) under anaesthesia to establish temperature-corrected reference intervals for arterial blood gas values and to compare them to temperature-corrected venous blood gas values with a portable point-of-care blood gas analyzer (i-STAT 1, Abbott Laboratories, Abbott Park, IL, USA). Statistically significant differences were observed between the temperature-corrected values of pH, partial pressure of carbon dioxide (Pco2), and partial pressure of oxygen (Po2) and the corresponding nontemperature-corrected values of these parameters in both arterial and venous blood. Values of temperature-corrected pH, temperature-corrected Pco2, bicarbonate concentrations, and base excess of extra cellular fluid did not differ significantly between arterial and venous blood, suggesting that, in anesthetized gyr falcons, venous blood gas analysis can be used in place of arterial blood gas analysis in clinical situations. Values for hematocrit, measured by the point-of-care analyzer, were significantly lower compared with those obtained by the microhematocrit method.

  13. The scope for generating bio-oils with relatively low oxygen contents via hydropyrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, J.D. [Strathclyde Univ., Glasgow (United Kingdom). Dept. of Pure and Applied Chemistry; Universidade Estadual de Campinas (Brazil). Dept. Fisica Aplicada; Luengo, C.A. [Universidade Estadual de Campinas (Brazil). Dept. Fisica Aplicada; Snape, C.E. [Strathclyde Univ., Glasgow (United Kingdom). Dept. of Pure and Applied Chemistry

    1999-07-01

    The primary oils obtained in high yields from fast (fluidised-bed) pyrolysis of biomass generally have high oxygen contents (ca. 40% w/w). The scope for using pyrolysis under hydrogen pressure (hydropyrolysis), to give oils with much lower oxygen contents compared to normal pyrolysis has been investigated. Fixed-bed hydropyrolysis tests have been conducted on cellulose, sugar cane bagasse and eucalyptus wood using hydrogen pressures up to 10 MPa, with heating rates of 5 and 300{sup o}C min{sup -1}. A colloidal FeS catalyst was used in some tests (Fe loading of 5%, w/w) to increase overall conversions. Further, the attractive option of using a two-stage reactor in which the primary oil vapors are passed though a bed of hydrotreating catalyst is also described. Raising the hydrogen pressure from atmospheric to 10 MPa reduced the oxygen content of the primary oil by over 10% to below 20% w/w. The addition of a dispersed iron sulphide catalyst gave conversions close to 100% for all three biomass samples investigated at 10 MPa under conditions in the fixed-bed reactor where significant diffusional resistances existed and reduced the oxygen content of the bio-oil by a further 10%. Although NMR indicated that the oils became increasingly aromatic as more oxygen was removed, the increase in hydrogen pressure decreased the extent of overall aromatisation that occurs primarily due to the lower char yields obtained. In two-stage tests for cellulose, using a commercial sulphided Ni/Mo {gamma}-Al{sub 2}O{sub 3} catalyst at 400{sup o}C, increasing the hydrogen pressure from 2.5 to 10 MPa decreased the oxygen content of the oil by over 20% to 10% w/w. The H/C ratios were higher and O/C ratios smaller for the two-stage bio-oils compared to their single stage counterparts. However, the differences in the O/C ratios between the single and two-stage bio-oils increase with pressure. (author)

  14. Uteroplacental arterio-venous difference in soluble VEGFR-1 (sFlt-1), but not in soluble endoglin concentrations in preeclampsia.

    Science.gov (United States)

    Paasche Roland, M C; Lorentzen, B; Godang, K; Henriksen, T

    2012-03-01

    The aim was to determine plasma levels of sFlt-1 and sEng on the arterial and venous side of the uteroplacental circulation in preeclamptic patients and healthy controls. Preeclamptic patients had higher arterial concentrations than controls of sFlt-1 (17,450 vs. 5055 pg/ml, p = 0.003) and sEng (68.7 vs. 28.7 ng/ml, p = 0.003). In the preclampsia group sFlt-1 was higher in the uterine vein than in the radial artery (22,450 vs. 17,450 pg/ml, p = 0.005). We found no gradient for sEng. Our results support the hypothesis that excess sFlt-1 at least partly originates in placenta, while excess sEng appears to have a different origin. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Reduced deep regional cerebral venous oxygen saturation in hemodialysis patients using quantitative susceptibility mapping.

    Science.gov (United States)

    Chai, Chao; Liu, Saifeng; Fan, Linlin; Liu, Lei; Li, Jinping; Zuo, Chao; Qian, Tianyi; Haacke, E Mark; Shen, Wen; Xia, Shuang

    2018-02-01

    Cerebral venous oxygen saturation (SvO 2 ) is an important indicator of brain function. There was debate about lower cerebral oxygen metabolism in hemodialysis patients and there were no reports about the changes of deep regional cerebral SvO 2 in hemodialysis patients. In this study, we aim to explore the deep regional cerebral SvO 2 from straight sinus using quantitative susceptibility mapping (QSM) and the correlation with clinical risk factors and neuropsychiatric testing . 52 hemodialysis patients and 54 age-and gender-matched healthy controls were enrolled. QSM reconstructed from original phase data of 3.0 T susceptibility-weighted imaging was used to measure the susceptibility of straight sinus. The susceptibility was used to calculate the deep regional cerebral SvO 2 and compare with healthy individuals. Correlation analysis was performed to investigate the correlation between deep regional cerebral SvO 2 , clinical risk factors and neuropsychiatric testing. The deep regional cerebral SvO 2 of hemodialysis patients (72.5 ± 3.7%) was significantly lower than healthy controls (76.0 ± 2.1%) (P deep regional cerebral SvO 2 in patients. The Mini-Mental State Examination (MMSE) scores of hemodialysis patients were significantly lower than healthy controls (P deep regional cerebral SvO 2 did not correlate with MMSE scores (P = 0.630). In summary, the decreased deep regional cerebral SvO 2 occurred in hemodialysis patients and dialysis duration, parathyroid hormone, hematocrit, hemoglobin and red blood cell may be clinical risk factors.

  16. Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study.

    Science.gov (United States)

    Hudacko, Andrea; Sievert, Alicia; Sistino, Joseph

    2009-09-01

    Miniaturizing cardiopulmonary bypass (CPB) circuits to reduce hemodilution and allogenic blood product administration is common in cardiac surgery. One major concern associated with smaller CPB circuits is a possible increase in gaseous microemboli (GME) sent to the cerebral vasculature, which is exacerbated by vacuum-assisted venous drainage (VAVD). The use of VAVD has increased with smaller venous line diameter and venous cannulae. This study examines the effects of CPB initiation with an unprimed venous line and VAVD in a pediatric circuit. A CPB circuit was set up with reservoir, oxygenator, and arterial filter with a bag reservoir to simulate the patient. All trials were done in vitro, and GME were measured using the EDAC Quantifier by Luna Innovations. EDAC sensors were placed proximal and distal to the oxygenator and distal to the arterial filter. Group 1 was the control group with no VAVD and a primed venous line. Groups 2, 3, and 4 used an unprimed venous line and VAVD of -40, -20, and -10 mmHg, respectively. Total microemboli counts and total embolic load in micrometers were measured at each sensor. Groups 2 (12,379.00 +/- 3180.37) and 3 (8296.67 +/- 2818.76) had significantly more microemboli than group 1 (923.33 +/- 796.08, p sensor. Group 2 (57.33 +/- 25.01, p sensor. No other findings were statistically significant. The results suggest that, if an oxygenator and arterial filter with sufficient air handling capabilities are used, this method to reduce prime volume may not increase GME in the arterial line distal to the arterial filter.

  17. In-vivo continuous monitoring of mixed venous oxygen saturation by photoacoustic transesophageal echocardiography (Conference Presentation)

    Science.gov (United States)

    Li, Li; Subramaniam, Balachundhar; Aguirre, Aaron D.; Andrawes, Michael N.; Tearney, Guillermo J.

    2016-02-01

    Mixed venous oxygen saturation (SvO2), measured from pulmonary arteries, is a gold-standard measure of the dynamic balance between the oxygen supply and demand in the body. In critical care, continuous monitoring of SvO2 plays a vital role in early detection of circulatory shock and guiding goal-oriented resuscitation. In current clinical practice, SvO2 is measured by invasive pulmonary artery catheters (PAC), which are associated with a 10% risk of severe complications. To address the unmet clinical need for a non-invasive SvO2 monitor, we are developing a new technology termed photoacoustic transesophageal echocardiography (PA-TEE). PA-TEE integrates transesophageal echocardiography with photoacoustic oximetry, and enables continuous assessment of SvO2 through an esophageal probe that can be inserted into the body in a minimally invasive manner. We have constructed a clinically translatable PA-TEE prototype, which features a mobile OPO laser, a modified ultrasonography console and a dual-modality esophageal probe. Comprised of a rotatable acoustic array detector, a flexible optical fiber bundle and a light-integrating acoustic lens, the oximetric probe has an outer diameter smaller than 15 mm and will be tolerable for most patients. Through custom-made C++/Qt software, our device acquires and displays ultrasonic and photoacoustic images in real time to guide the deployment of the probe. SvO2 is calculated on-line and updated every second. PA-TEE has now been used to evaluate SvO2 in living swine. Our findings show that changing the fraction of oxygen in the inspired gas modulates SvO2 measured by PA-TEE. Statistic comparison between SvO2 measurements from PA-TEE in vivo the gold-standard laboratorial analysis on blood samples drawn from PACs will be presented.

  18. Venous and Arterial Thromboses: Two Sides of the Same Coin?

    Science.gov (United States)

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2018-04-01

    Arterial and venous thromboses are sustained by development of intraluminal thrombi, respectively, within the venous and arterial systems. The composition and structure of arterial and venous thrombi have been historically considered as being very different. Arterial thrombi (conventionally defined as "white") have been traditionally proposed to be composed mainly of fibrin and platelet aggregates, whilst venous thrombi (conventionally defined as "red") have been proposed as mostly being enriched in fibrin and erythrocytes. This archaic dichotomy seems ever more questionable, since it barely reflects the pathophysiology of thrombus formation in vivo. Both types of thrombi are actually composed of a complex fibrin network but, importantly, also contain essentially the same blood-borne cells (i.e., red blood cells, leukocytes, and platelets), and it is only the relative content of these individual elements that differ between venous and arterial clots or, otherwise, between thrombi generated under different conditions of blood flow and shear stress. Convincing evidence now suggests that either white or red intracoronary thrombi may be present in patients with myocardial infarction and, even more importantly, red thrombi may be more prone to distal embolization during percutaneous coronary intervention than those with lower content of erythrocytes. Conversely, it is now accepted that components traditionally considered to be involved "only" in arterial thrombosis are also represented in venous thrombosis. Thus, platelets comprise important components of venous clots, although they may be present in lower amounts here than in arterial thrombi, and von Willebrand factor is also represented in both arterial and venous thrombi. Of importance, such evidence thus supports the concept that adjunctive treatment normally associated to prevention of arterial thrombosis (e.g., aspirin) may have a role also in prevention and treatment of venous thrombosis. Thieme Medical

  19. Evaluation of 133Xe clearance curves in the study of lingual blood flow in dogs

    International Nuclear Information System (INIS)

    Fazekas, A.; Posch, E.; Harsing, L.

    1979-01-01

    Lingual blood flow was studied in dogs by the 133 Xe clearance technique under control conditions, during epinephrine infusion and in response to a combined treatment with regitin and epinephrine. The composite washout curves recorded during control conditions could be resolved into three monoexponential components. It is suggested that the steep initial slope (component I) is caused by the fraction of blood that perfuses the A-V anastomoses of the tongue. Components II and III appear to indicate the perfusion rate of lingual mucosa and musculature, respectively. The disappearance of component I due to the effect of epinephrine infusion might indicate the closure of arterio-venous anastomoses containing alpha receptors. Regitin pretreatment could prevent the closure of the arterio-venous anastomoses elicited by epinephrine infusion. The beta receptor stimulating activity of epinephrine might account for the augmentation of blood flow to lingual musculature. (orig.) 891 AJ/orig. 892 BRE [de

  20. Effects of oxygen contents on the electrochromic properties of tungsten oxide films prepared by reactive magnetron sputtering

    International Nuclear Information System (INIS)

    Lu, H.-H.

    2008-01-01

    The electrochromism have been extensively investigated due to their potential applications such as smart window of architecture and automobile glazing to save energy and modulate the transmittance of light and solar radiation. The objective of this study is to investigate the effects of sputtering conditions on the microstructure and electrochromic properties of tungsten oxide films prepared by dc reactive magnetron sputtering. Experimental results showed that the deposition rate of WO 3-y films decreased with increasing oxygen flow rate. XRD and Raman spectra analysis suggests that the WO 3-y films deposited at various oxygen flow rates are poor crystallinity or amorphous. The transmission change between colored and bleached states at a wavelength of 550 nm was 61.4% as the oxygen content was 60%. The coloration efficiency slightly increases with increasing oxygen flow rate in the low oxygen content region and reaching a maximum value of 38.94 cm 2 /C at 60% oxygen content. In addition, the films deposited at 60% oxygen content showed a good reversibility. The effects of lithium ions intercalated on the transmission of WO 3-y films were also discussed

  1. Effects of Changes in Arterial Carbon Dioxide and Oxygen Partial Pressures on Cerebral Oximeter Performance.

    Science.gov (United States)

    Schober, Andrew; Feiner, John R; Bickler, Philip E; Rollins, Mark D

    2018-01-01

    Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P oxygen extraction (P < 0.0001). Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.

  2. Aneurisma y fístula arterio-venosa renal: manejo quirúrgico laparoscópico asistido por robot

    OpenAIRE

    CASTILLO C,OCTAVIO A; CUENTAS J,MARIANO; VIDANGOS V,RUBÉN; GUTIÉRREZ,RODRIGO; PALAVECINO R,PATRICIO

    2013-01-01

    Introducción: Los aneurismas de la arteria renal constituyen una patología infrecuente, y plantean dificultades en la decisión terapéutica. Objetivo: Presentar un caso de un aneurisma complejo intrarenal, asociado a una fístula arterio-venosa de alto flujo, el cual fue resuelto con asistencia robótica. Caso clínico: Paciente de 51 años, con historia prolongada de hipertensión arterial, al cual, en estudio radiológico de rutina, se le diagnostica 3 aneurismas intrarenales derechos, asociado a ...

  3. Determination of oxygen content in high Tc superconductors by deuteron particle activation analysis

    International Nuclear Information System (INIS)

    Tao Zhenlan; Yao, Y.D.; Kao, Y.H.

    1993-01-01

    The experimental method for determining the oxygen content in high T c superconductors is described in detail. This method is applied to determination of oxygen content in high T c Y-Ba-Cu-O and Bi-Sr-Ca-Cu-O samples in which the stoichiometry is varied by reducing the copper and bismuth concentrations. The oxygen concentration is found to vary linearly with Cu(x = 0-0.2) and Bi (x = 0-0.4) deficiencies in YBa 2 Cu 3(1-x )O y and Bi 2(1-x) Sr 2 CaCu 2 O y respectively. X-ray powder diffraction measurements show that the compound of YBa 2 Cu 3(1-x) O y is orthorhombic in the variation range of x = 0-0.2

  4. Oxygen Transport: A Simple Model for Study and Examination.

    Science.gov (United States)

    Gaar, Kermit A., Jr.

    1985-01-01

    Describes an oxygen transport model computer program (written in Applesoft BASIC) which uses such variables as amount of time lapse from beginning of the simulation, arterial blood oxygen concentration, alveolar oxygen pressure, and venous blood oxygen concentration and pressure. Includes information on obtaining the program and its documentation.…

  5. Effects of Oxygen Content of Fuels on Combustion and Emissions of Diesel Engines

    Directory of Open Access Journals (Sweden)

    Haiwen Song

    2016-01-01

    Full Text Available Effects of oxygen content of fuels on combustion characteristics and emissions were investigated on both an optical single cylinder direct injection (DI diesel engine and a multi-cylinder engine. Three fuels were derived from conventional diesel fuel (Finnish City diesel summer grade by blending Rapeseed Methyl Ester (RME or Diglyme and Butyl-Diglyme of different quantities to make their oxygen content 3%, 3% and 9%, respectively. The experimental results with three tested fuels show that the fuel spray development was not affected apparently by the oxygenating. Compared with the base fuel, the ignition delay to pilot injection was shortened by 0%, 11% and 19% for three oxygenated fuels, respectively. The ignition delay to main injection was shortened by 10%, 19% and 38%, respectively. With regard to emissions, the smoke level was reduced by 24% to 90%, depending on fuel properties and engine running conditions. The penalties of increased NOx emissions and fuel consumption were up to 19% and 24%, respectively.

  6. Determination of oxygen content in high T/sub c/ superconductors by a charged particle activation method

    International Nuclear Information System (INIS)

    Tao, Z.; Alburger, D.E.; Jones, K.W.; Yao, Y.D.; Kao, Y.H.

    1988-01-01

    A new method for determining the oxygen content in high T/sub c/ superconductors has been demonstrated using a charged particle activation technique. This method allows a measurement of the concentration of 16 O atoms in the superconducting material by detection of the 17 F produced with the 16 O(d,n) 17 F nuclear reaction. By way of example, this technique is applied to the determination of oxygen content in a series of high T/sub c/ Y-Ba-Cu-O samples in which the stoichiometry is varied by reducing the copper concentration. The stabilized oxygen content shows a nonlinear dependence on the copper deficiency in these specimens

  7. The oxygen content of the high-temperature superconducting compound Bi2+xSr3-yCayCu2O8+d with respect to varying Ca and Bi contents

    International Nuclear Information System (INIS)

    Majewski, P.; Su, H.L.; Aldinger, F.

    1994-01-01

    The oxygen content of Bi 2+x Sr 3-y Ca y Cu 2 O 8+d (2212 phase) has been determined as a function of its cation concentration. With increasing Ca and Bi content the oxygen content increases and T c decreases. The oxygen content of Ca rich 2212 phase increases with decreasing annealing temperatures. The study shows that the T c of the 2212 phase primarily is controlled by its cation concentration

  8. Measurement of forearm oxygen consumption

    DEFF Research Database (Denmark)

    Astrup, A; Simonsen, L; Bülow, J

    1988-01-01

    The classical forearm technique widely used for studies of skeletal muscle metabolism requires arterial cannulation. To avoid arterial puncture it is becoming more common to arterialize blood from a contralateral hand vein by local heating. This modification and the classical method have produced...... blood flow and decreases skeletal muscle blood flow. This facilitates mixing of superficial blood with deep venous blood. Contralateral heating increased deep venous oxygen saturation and abolished the pronounced glucose-induced increase in oxygen consumption observed in the control experiments after...... contradictory results regarding the contribution of skeletal muscle to glucose-induced thermogenesis. The effect on forearm circulation and the metabolism of heating the contralateral hand was examined before and after an oral glucose load. The results suggest that contralateral heating increases subcutaneous...

  9. A Method for Combined Retinal Vascular and Tissue Oxygen Tension Imaging.

    Science.gov (United States)

    Felder, Anthony E; Wanek, Justin; Tan, Michael R; Blair, Norman P; Shahidi, Mahnaz

    2017-09-06

    The retina requires adequate oxygenation to maintain cellular metabolism and visual function. Inner retinal oxygen metabolism is directly related to retinal vascular oxygen tension (PO 2 ) and inner retinal oxygen extraction fraction (OEF), whereas outer retinal oxygen consumption (QO 2 ) relies on oxygen availability by the choroid and is contingent upon retinal tissue oxygen tension (tPO 2 ) gradients across the retinal depth. Thus far, these oxygenation and metabolic parameters have been measured independently by different techniques in separate animals, precluding a comprehensive and correlative assessment of retinal oxygenation and metabolism dynamics. The purpose of the current study is to report an innovative optical system for dual oxyphor phosphorescence lifetime imaging to near-simultaneously measure retinal vascular PO 2 and tPO 2 in rats. The use of a new oxyphor with different spectral characteristics allowed differentiation of phosphorescence signals from the retinal vasculature and tissue. Concurrent measurements of retinal arterial and venous PO 2 , tPO 2 through the retinal depth, inner retinal OEF, and outer retinal QO 2 were demonstrated, permitting a correlative assessment of retinal oxygenation and metabolism. Future application of this method can be used to investigate the relations among retinal oxygen content, extraction and metabolism under pathologic conditions and thus advance knowledge of retinal hypoxia pathophysiology.

  10. Cerebral venous system and anatomical predisposition to high-altitude headache

    NARCIS (Netherlands)

    Wilson, Mark H.; Davagnanam, Indran; Holland, Graeme; Dattani, Raj S.; Tamm, Alexander; Hirani, Shashivadan P.; Kolfschoten, Nicky; Strycharczuk, Lisa; Green, Cathy; Thornton, John S.; Wright, Alex; Edsell, Mark; Kitchen, Neil D.; Sharp, David J.; Ham, Timothy E.; Murray, Andrew; Holloway, Cameron J.; Clarke, Kieran; Grocott, Mike P. W.; Montgomery, Hugh; Imray, Chris; Ahuja, V.; Aref-Adib, G.; Burnham, R.; Chisholm, A.; Clarke, K.; Coates, D.; Coates, M.; Cook, D.; Cox, M.; Dhillon, S.; Dougall, C.; Doyle, P.; Duncan, P.; Edsell, M.; Edwards, L.; Evans, L.; Gardiner, P.; Grocott, M.; Gunning, P.; Hart, N.; Harrington, J.; Harvey, J.; Holloway, C.; Howard, D.; Hurlbut, D.; Imray, C.; Ince, C.; Jonas, M.; van der Kaaij, J.

    2013-01-01

    As inspired oxygen availability falls with ascent to altitude, some individuals develop high-altitude headache (HAH). We postulated that HAH results when hypoxia-associated increases in cerebral blood flow occur in the context of restricted venous drainage, and is worsened when cerebral compliance

  11. Gradually Increased Oxygen Administration Improved Oxygenation and Mitigated Oxidative Stress after Resuscitation from Severe Hemorrhagic Shock.

    Science.gov (United States)

    Luo, Xin; Yin, Yujing; You, Guoxing; Chen, Gan; Wang, Ying; Zhao, Jingxiang; Wang, Bo; Zhao, Lian; Zhou, Hong

    2015-11-01

    The optimal oxygen administration strategy during resuscitation from hemorrhagic shock (HS) is still controversial. Improving oxygenation and mitigating oxidative stress simultaneously seem to be contradictory goals. To maximize oxygen delivery while minimizing oxidative damage, the authors proposed the notion of gradually increased oxygen administration (GIOA), which entails making the arterial blood hypoxemic early in resuscitation and subsequently gradually increasing to hyperoxic, and compared its effects with normoxic resuscitation, hyperoxic resuscitation, and hypoxemic resuscitation in severe HS. Rats were subjected to HS, and on resuscitation, the rats were randomly assigned to four groups (n = 8): the normoxic, the hyperoxic, the hypoxemic, and the GIOA groups. Rats were observed for an additional 1 h. Hemodynamics, acid-base status, oxygenation, and oxidative injury were observed and evaluated. Central venous oxygen saturation promptly recovered only in the hyperoxic and the GIOA groups, and the liver tissue partial pressure of oxygen was highest in the GIOA group after resuscitation. Oxidative stress in GIOA group was significantly reduced compared with the hyperoxic group as indicated by the reduced malondialdehyde content, increased catalase activity, and the lower histologic injury scores in the liver. In addition, the tumor necrosis factor-α and interleukin-6 expressions in the liver were markedly decreased in the GIOA group than in the hyperoxic and normoxic groups as shown by the immunohistochemical staining. GIOA improved systemic/tissue oxygenation and mitigated oxidative stress simultaneously after resuscitation from severe HS. GIOA may be a promising strategy to improve resuscitation from HS and deserves further investigation.

  12. Impact of initial lipid content and oxygen supply on alcoholic fermentation in champagne-like musts.

    Science.gov (United States)

    Ochando, Thomas; Mouret, Jean-Roch; Humbert-Goffard, Anne; Sablayrolles, Jean-Marie; Farines, Vincent

    2017-08-01

    Available nitrogen, lipids, or oxygen are nutrients with major impact on the kinetics of winemaking fermentation. Assimilable nitrogen is usually the growth-limiting nutrient which availability determines the fermentation rate and therefore the fermentation duration. In some particular cases, as in Champagne, grape musts have high available nitrogen content and low turbidity, i.e., below 50 Nephelometric Turbidity Unit (NTU). In the case of low turbidity, the availability of lipids, particularly phytosterols, becomes limiting. In this situation, control of oxygenation, which is necessary for lipid synthesis by yeast, is particularly crucial during fermentation. To mimic and understand these situations, a synthetic medium simulating the average composition of a Champagne must was used. This medium contained phytosterol (mainly β-sitosterol) concentrations ranging from 0 to 8mg/L corresponding to turbidity between 10 and 90 NTU. Population reached during the stationary phase and the maximum fermentation rate are conditioned by the initial phytosterol concentration determining the amount of nitrogen consumption. An early loss of viability was observed when the lipid concentrations were very low. For example, the viability continuously decreased during the stationary phase to a final value of 50% for an initial phytosterol concentration of 1mg/L. In some fermentations, 10mg/L oxygen were added at the end of the growth phase to combine the effects of initial content of phytosterols in the musts and the de novo synthesis of ergosterol and unsaturated fatty acids induced by oxygen addition. Effect of oxygen supply on the fermentation kinetics was particularly significant for media with low phytosterol contents. For example, the maximum fermentation rate was increased by 1.4-fold and the fermentation time was 70h shorter with oxygen addition in the medium containing 2mg/L of phytosterols. As a consequence of the oxygen supply, for the media containing 3, 5 and 8mg/L of

  13. Correlation Between Grain Size Distribution and Silicon and Oxygen Contents at Wadi Arar Sediments, Kingdom of Saudi Arabia

    Directory of Open Access Journals (Sweden)

    M. A. M. Alghamdi

    2017-08-01

    Full Text Available Quartz is the major mineral of Wadi Arar sediments. The top two elements contents are oxygen with 63.96 wt%, followed by silicon with 16.35 wt%. There is a positive, weak to medium correlation between grain size and silicon and oxygen contents. The correlation between oxygen and grain size is four times higher than that of silicon. At grain size ranges between 0.8 and 1.0 mm, both oxygen and silicon show the maximum correlation, which decrease gradually with finer and coarser grain sizes. For each element, the correlation between the element content and grain size is a fourth degree polynomial in the grain size. Theoretically, the best two math models that represent the relation between the grain size distribution and each of individual oxygen and silicon content are y=8.84∙ln(x+39.5 and y=2.26∙ln(x+10.1 respectively, where y represents the element content percentage and x represents the corresponding grain size in mm.

  14. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  15. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  16. A reduced cerebral metabolic ratio in exercise reflects metabolism and not accumulation of lactate within the human brain

    DEFF Research Database (Denmark)

    Dalsgaard, Mads K; Quistorff, Bjørn; Danielsen, Else R

    2003-01-01

    During maximal exercise lactate taken up by the human brain contributes to reduce the cerebral metabolic ratio, O(2)/(glucose + 1/2 lactate), but it is not known whether the lactate is metabolized or if it accumulates in a distribution volume. In one experiment the cerebral arterio-venous differe......During maximal exercise lactate taken up by the human brain contributes to reduce the cerebral metabolic ratio, O(2)/(glucose + 1/2 lactate), but it is not known whether the lactate is metabolized or if it accumulates in a distribution volume. In one experiment the cerebral arterio......-venous differences (AV) for O(2), glucose (glc) and lactate (lac) were evaluated in nine healthy subjects at rest and during and after exercise to exhaustion. The cerebrospinal fluid (CSF) was drained through a lumbar puncture immediately after exercise, while control values were obtained from six other healthy.......0 to 0.9 +/- 0.1 mM (P ratio from 6.0 +/- 0.3 to 2.8 +/- 0.2 (P

  17. Malformación vascular intraósea en el maxilar que se presenta en forma de sangrado gingival Intra-osseous vascular malformation in the maxilla

    Directory of Open Access Journals (Sweden)

    Naveenjayakumar

    2009-12-01

    Full Text Available Las malformaciones arterio-venosas intraóseas (MAVs en la región maxilofacial son entidades clínicas poco frecuentes. Ofrecen una amplia gama de presentación clínica y no siempre se diagnostican sin sorpresa. El tratamiento de estas lesiones siempre ha representado un reto para el cirujano debido a su intensa vascularización y a la elevada incidencia de recurrencia. Se presenta el caso de una malformación arterio-venosa intraósea en el maxilar superior que se manifiesta como sangrado gingival, cuyos exámenes radiológicos de rutina no fueron concluyentes. Se llevó a cabo la excisión quirúrgica y el empaquetado del hueso con cera, y se realizó el seguimiento del paciente durante 1 año sin que se produjera recurrencia. Las malformaciones vasculares deben tenerse en consideración en el diagnóstico diferencial del sangrado gingival con radiografías dentales no concluyentes.Intraosseous arterio-venous malformations (AVM in the maxillofacial region are rare clinical entities. They have a wide range of clinical presentation and are not always diagnosed without a surprise. Treatment of these lesions has always been a challenge to the surgeon due to extreme vascularity and the high recurrence rate. The case presented is that of an intraosseous arterio-venous malformation in the maxilla that started as gingival bleeding and routine radiographic examinations were inconclusive. Surgical excision and bone wax packing was performed there were no recurrences during 1-year of follow-up. Vascular malformations may be considered in differential diagnosis of gingival bleeding with inconclusive dental radiographs.

  18. A Simple Experiment To Measure the Content of Oxygen in the Air Using Heated Steel Wool

    Science.gov (United States)

    Vera, Francisco; Rivera, Rodrigo; Nunez, Cesar

    2011-01-01

    The typical experiment to measure the oxygen content in the atmosphere uses the rusting of steel wool inside a closed volume of air. Two key aspects of this experiment that make possible a successful measurement of the content of oxygen in the air are the use of a closed atmosphere and the use of a chemical reaction that involves the oxidation of…

  19. Bilateral Pneumothoraces Following Central Venous Cannulation

    OpenAIRE

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right ...

  20. Effects of blood transfusion on oxygen extraction ratio and central venous saturation in children after cardiac surgery.

    Science.gov (United States)

    Nasser, Bana; Tageldein, Mohmad; AlMesned, Abdulrahman; Kabbani, Mohammad

    2017-01-01

    Red blood cell transfusion is common in critically ill children after cardiac surgery. Since the threshold for hemoglobin (Hb) transfusion need is not well defined, the threshold Hb level at which dependent critical oxygen uptake-to-delivery (VO2-DO2) status compensation is uncertain. To assess the effects of blood transfusion on the oxygen extraction ratio (O2ER) and central venous oxygen saturation (ScvO2) to identify a critical O2ER value that could help us determine the critical need for blood transfusion. Prospective, observational cohort study. Cardiac Surgical Intensive Care Unit at Prince Sultan Cardiac Center in Qassim, Saudi Arabia. Between January 2013 and December 2015, we included all children with cardiac disease who underwent surgery and needed a blood transfusion. Demographic and laboratory data with physiological parameters before and 1 and 6 hours after transfusion were recorded and O2ER before and 6 hours after transfusion was computed. Cases were divided into two groups based on O2ER: Patients with increased O2ER (O2ER > 40%) and normal patients without increased O2ER (O2ER transfusion. Changes in O2ER and ScvO2 following blood transfusion. Of 103 patients who had blood transfusion, 75 cases had normal O2ER before transfusion while 28 cases had increased O2ER before transfusion. Following blood transfusion, O2ER and ScvO2 improved in the group that had increased O2ER before transfusion, but not in the group that had normal O2ER before transfusion. The clinical and hemodynamic indicators O2ER and ScvO2 may be considered as markers that can indicate a need for blood transfusion. The limitation of this study is the small number of patients that had increased O2ER before transfusion. There were few available variables to assess oxygen consumption.

  1. Effect of hydrogen and oxygen content on the embrittlement of Zr alloys

    International Nuclear Information System (INIS)

    Griger, A.; Hozer, Z.; Matus, L.; Vasaros, L.; Horvath, M.

    2001-01-01

    An experimental study is carried out in the KFKI Atomic Energy Research Institute in order to clear up the role of oxidation and hydrogen uptake in the embrittlement process. Russian E110 type Zr1%Nb and Zircaloy-4 claddings are used as test materials. The differences between the properties of two alloys are examined. The sample preparation covered the following cases: oxidation in Ar+O 2 atmosphere; hydrogen uptake of as received and pre-oxidised samples (in Ar+O 2 atmosphere); oxidation in steam. The oxidation in Ar+O 2 and the subsequent hydrogen uptake procedure make possible the production of samples with well-characterized hydrogen and oxygen content. Corrosion treated ring samples of 8 mm height are examined in ring compression tests. The force-deformation curves are recorded and the crushing force and deformation are determined. The relative deformation is used for the characterisation of embrittlement level. The results of experiments provide detailed information about the effect of hydrogen and oxygen content on the embrittlement of zirconium alloys. The conclusions are: 1) hydrogen seems to play a more important role in the embrittlement of zirconium alloys than oxygen; 2) the Zircaloy-4 alloy becomes brittle at lower hydrogen content than the Zr1%Nb; 3) under steam oxidation conditions the Zr1%Nb alloy takes up much more hydrogen and becomes more brittle than the Zircaloy-4

  2. L-lysine escinat, thiotriazolin, gordox and mydocalm influence on oxygen tension in the intestinal wall and acid-base balance and limited proteolysis in intestinal venous blood in terms of intraabdominal hypertension modeling

    Directory of Open Access Journals (Sweden)

    Sapegin V.I.

    2014-11-01

    Full Text Available In acute experiments on rabbits there were studied changes in oxygen tension in the intestinal wall tissues, acid-base balance and limited proteolysis and its inhibitors in intestinal venous blood, protective action of L-lysine escinat (0,15 mg/kg / single dose, thiotriazolin (25 mg/kg / single dose, aprotinin (gordox (10,000 units/kg / single dose in sequential modeling of standard levels increasing of intra-abdominal hypertension (IAH — 50, 100, 150, 200, 250, 300, 350 m H2O, and also of tolperison (mydocalm (5 mg/kg / single dose on modeling of stable 3-hour IAH 200 m H2O. The IAH modeling was performed by means of stand of our construction. Under the influence of IAH the compensated metabolic acidosis in intestinal venous blood with a compensative hyperpnoe develops, decline of oxygen tension in tissues and activating of a limited proteolysis as well as decline of its inhibitors activity in intestinal venous blood occur. By the degree of metabolic acidosis prevention investigational preparations were distributed as follows gordox > thiotriazolin = L-lysine escinat = mydocalm, and by prevention of decline of oxygen tension in tissues — thiotriazolin > L-lysine escinat > mydocalm > gordox, it is is connected with different rate of methabolic products excretion into the blood, due to the influence on blood circulation and transcapilary exchange. By the degree of prevention of proteolytic activity and inhibitory potential changes, investigational preparations were distributed as follows: gordox > mydocalm > thiotriazolin > L-lysine escinat, this is connected with inhibition of proteolysis in gordox, and in other ones – with reduction of ischemic damage of tissues. Owing to different mechanism of action thiotriazolin, L-lysine escinat and mydocalm may be simultaneously recommended for a conservative treatment of patients with intraabdominal hypertension syndrome.

  3. Ignition and devolatilization of pulverized coals in lower oxygen content O{sub 2}/CO{sub 2} atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiaohong; Li, Jing; Liu, Zhaohui; Yang, Ming; Wang, Dingbang; Zheng, Chuguang [Huazhong Univ. of Science and Technology, Wuhan (China). State Key Lab. of Coal Combustion

    2013-07-01

    High speed camera is employed to capture the transient images of the burning particle in a flat-flame entrained flow reactor, some information of the burning particle, such as the optical intensity and the residence time, are obtained through analysis of transient images. The ignition and devolatilization behavior of different rank coals at 1,670, 1,770 and 1,940 K over a range of 2-30% O{sub 2} in both N{sub 2} and CO{sub 2} diluent gases are researched. The results indicate that the laws of ignition and devolatilization of pulverized coals in low oxygen O{sub 2}/CO{sub 2} atmosphere are consistent with the literature, which focus on the environments of high oxygen contents (10-30%) or lower temperate (900-1,500 K). With the gas temperature and oxygen content increased, the ignition delay time and devolatilization time for the lower oxygen content cases decreased for both N{sub 2} and CO{sub 2} atmosphere. With the use CO{sub 2} in place of N{sub 2} in low oxygen content, the ignition delay was retarded and the duration of devolatilization was increased. The effect of CO{sub 2} on coal particle ignition is explained by its higher molar specific heat. And the effect of CO{sub 2} on devolatilization results from its effect on the diffusion rates of volatile fuel and oxygen.

  4. Relationship Between Cerebral Oxygenation and Hemodynamic and Oxygen Transport Parameters in Surgery for Acquired Heart Diseases

    Directory of Open Access Journals (Sweden)

    A. I. Lenkin

    2012-01-01

    Full Text Available Objective: to evaluate the relationship between cerebral oxygenation and hemodynamic and oxygen transport parameters in surgical correction of concomitant acquired heart diseases. Subjects and methods. Informed consent was received from 40 patients who required surgery because of concomitant (two or more acquired heart defects. During procedure, perioperative monitoring of oxygen transport and cerebral oxygenation was performed with the aid of PiCCO2 monitor (Pulsion Medical Systems, Germany and a Fore-Sight cerebral oximeter (CASMED, USA. Anesthesia was maintained with propofol and fen-tanyl, by monitoring the depth of anesthesia. Early postoperative intensive therapy was based on the protocol for early targeted correction of hemodynamic disorders. Oxygen transport and cerebral oxygenation parameters were estimated intraopera-tively and within 24 postoperative hours. A statistical analysis including evaluation of Spearman correlations was performed with the aid of SPSS 15.0. Results. During perfusion, there was a relationship between cerebral oximetry values and hemat-ocrit levels, and oxygen partial pressure in the venous blood. Furthermore, a negative correlation between cerebral oximetry values and blood lactate levels was found 30 minutes after initiation of extracorporeal circulation (EC. During the study, there was a positive correlation between cerebral oxygenation and values of cardiac index, central venous saturation, and oxygen delivery index. There was a negative relationship between cerebral oxygenation and extravascular lung water at the beginning of surgery and a correlation between cerebral oximetry values and oxygenation index by the end of the first 24 postoperative hours. Conclusion. The cerebral oxygenation values correlate -with the main determinants of oxygen transport during EC and after cardiac surgical procedures. Cerebral oximetry may be used in early targeted therapy for the surgical correction of acquired combined

  5. Effect of micro-oxygenation on color and anthocyanin-related compounds of wines with different phenolic contents.

    Science.gov (United States)

    Cano-López, Marta; Pardo-Mínguez, Francisco; Schmauch, Gregory; Saucier, Cedric; Teissedre, Pierre-Louis; López-Roca, Jose María; Gómez-Plaza, Encarna

    2008-07-23

    Several factors may affect the results obtained when micro-oxygenation is applied to red wines, the most important being the moment of application, the doses of oxygen, and the wine phenolic characteristics. In this study, three red wines, made from Vitis vinifera var. Monastrell (2005 vintage) and with different phenolic characteristics, were micro-oxygenated to determine as to how this technique affected the formation of new pigments in the wines and their chromatic characteristics. The results indicated that the different wines were differently affected by micro-oxygenation. In general, the micro-oxygenated wines had a higher percentage of new anthocyanin-derived pigments, being that this formation is more favored in the wines with the highest total phenol content. These compounds, in turn, significantly increased the wine color intensity. The wine with the lowest phenolic content was less influenced by micro-oxygenation, and the observed evolution in the degree of polymerization of tannins suggested that it might have suffered overoxygenation.

  6. Pulmonary venous flow index as a predictor of pulmonary vascular resistance variability in congenital heart disease with increased pulmonary flow: a comparative study before and after oxygen inhalation.

    Science.gov (United States)

    Rivera, Ivan Romero; Mendonça, Maria Alayde; Andrade, José Lázaro; Moises, Valdir; Campos, Orlando; Silva, Célia Camelo; Carvalho, Antonio Carlos

    2013-09-01

    There is no definitive and reliable echocardiographic method for estimating the pulmonary vascular resistance (PVR) to differentiate persistent vascular disease from dynamic pulmonary hypertension. The aim of this study was to analyze the relationship between the pulmonary venous blood flow velocity-time integral (VTIpv) and PVR. Eighteen patients (10 females; 4 months to 22 years of age) with congenital heart disease and left to right shunt were studied. They underwent complete cardiac catheterization, including measurements of the PVR and Qp:Qs ratio, before and after 100% oxygen inhalation. Simultaneous left inferior pulmonary venous flow VTIpv was obtained by Doppler echocardiography. The PVR decreased significantly from 5.0 ± 2.6 W to 2.8 ± 2.2 W (P = 0.0001) with a significant increase in the Qp:Qs ratio, from 3.2 ± 1.4 to 4.9 ± 2.4 (P = 0.0008), and the VTIpv increased significantly from 22.6 ± 4.7 cm to 28.1 ± 6.2 cm (P = 0.0002) after 100% oxygen inhalation. VTIpv correlated well with the PVR and Qp:Qs ratio (r = -0.74 and 0.72, respectively). Diagnostic indexes indicated a sensitivity of 86%, specificity of 75%, accuracy of 83%, a positive predictive value of 92% and a negative predictive value of 60%. The VTIpv correlated well with the PVR. The measurement of this index before and after oxygen inhalation may become a useful noninvasive test for differentiating persistent vascular disease from dynamic and flow-related pulmonary hypertension. © 2013, Wiley Periodicals, Inc.

  7. Effects of Chronic Blood-Flow Restriction Exercise on Skeletal Muscle Size and Myogenic Satellite Cell Expression

    DEFF Research Database (Denmark)

    Aagaard, Per; Jacobsen, Mikkel; Jensen, Kasper Y.

    2016-01-01

    This single-case study examined an arterio-venous shunt patient (20 year old male) where a main artery supplying the left leg in the deeper anterior pelvis was connected to a returning vein, possibly due to previous trauma received while playing high level Team Handball. Due to this A-V shunt...

  8. Brightness of venous blood in South American camelids: implications for jugular catheterization.

    Science.gov (United States)

    Grint, Nicola; Dugdale, Alexandra

    2009-01-01

    To compare the brightness of South American camelid venous blood to that of Equidae. Prospective clinical evaluation. Twelve South American camelids (eight llamas, four alpacas), eight horses and ponies (control group). Appropriately sized catheters were placed in the jugular vein of each animal under local anaesthesia. The blood spilt before the catheter was capped was caught on a white tile. A sample of blood was drawn for blood-gas analysis. The brightness of the blood (both on the tile and in the syringe) was matched to a colour chart (1 = darkest red, 8 = brightest red) by a single observer under bright light conditions. Packed cell volume (PCV) and partial pressure of oxygen (PvO(2)) in the blood were also measured on the syringe blood. Normally distributed data were compared using a two tailed t-test, and non-normally distributed data were compared using a Mann-Whitney U-test. Significance was set at p Camelid venous blood was significantly brighter red than that of horses and ponies both on the white tile (p = 0.0003) and in the syringe (p = 0.0001). PCV was significantly lower in camelids (32 +/- 4%) compared with horses (37 +/- 5%). Partial pressure of oxygen values were similar between groups. Jugular venous blood in alpacas and llamas is significantly brighter red than that of horses. Colour should not be used as a sole determinant of venous or arterial catheterization in this species.

  9. Plasma Catecholamines and Stress Assessment in Men Exposed to Moderate Altitudes.

    Science.gov (United States)

    1982-01-01

    posure, as evidenced by a significant fall in PC02 and a respiratory alkalosis , was able to improve blood oxygenation. Heart rate did not fall with...Survey . . . . 21 Oxygen Content and P02 ...... .. ..... 33 Venous PCO2 :’" 33 Venous pH . .. . . . . . . .. 37 Respiratory Rate ............. ... 37 Blood...a 68 L. Venous PC02 Levels . ... .............. 69 M. Venous pH. . .9. . . . . . .. . . . . . . . . . . . 70 N. Respiratory Rates

  10. Why do elephants flap their ears? | Wright | African Zoology

    African Journals Online (AJOL)

    The blood flow in the ear of the African elephant Loxodonta africana was measured In anaesthetized animals using the dye dilution technique at the same time as the arterio-venous temperature difference. The calculated heat loss from the ear is shown to be a substantial proportion of the total metabolic heat-loss ...

  11. Structural and electronic transformations in substituted La-Sr manganites depending on cations and oxygen content

    Science.gov (United States)

    Karpasyuk, Vladimir; Badelin, Alexey; Merkulov, Denis; Derzhavin, Igor; Estemirova, Svetlana

    2018-05-01

    In the present research experimental data are obtained for the Jahn-Teller O‧ phase formation, phase transformation "orthorhombic-rhombohedral structure" and the change of the conductance type in the systems of manganites La3+1-c+xSr2+c-xMn3+1-c-x-2γMn4+c+2γZn2+xO3+γ, La3+1-c-xSr2+c+xMn3+1-c-x-2γMn4+c+2γGe4+xO3+γ, La3+1-cSr2+cMn3+1-x-c-2γMn4+c+2γ(Zn2+0.5Ge4+0.5)xO3+γ, where Mn4+ ions concentration is independent of "x". Ceramic samples were sintered in air at 1473 K. As-sintered samples had an excess of oxygen content. In order to provide stoichiometric oxygen content, the samples were annealed at 1223 K and partial pressure of oxygen PO2 = 10-1 Pа. Structural characteristics of the O‧ phase were obtained. The position of the phase boundary "orthorhombic-rhombohedral structure" and the temperature of the conductance type change depending on the cation composition of manganites and oxygen content were determined. Possible approaches to the interpretation of experimental results were suggested.

  12. The influence of advanced age on venous-arterial extracorporeal membrane oxygenation outcomes.

    Science.gov (United States)

    Salna, Michael; Takeda, Koji; Kurlansky, Paul; Ikegami, Hirohisa; Fan, Liqiong; Han, Jiho; Stein, Samantha; Topkara, Veli; Yuzefpolskaya, Melana; Colombo, Paolo C; Karmpaliotis, Dimitrios; Naka, Yoshifumi; Kirtane, Ajay J; Garan, Arthur R; Takayama, Hiroo

    2018-01-22

    Ethical and health care economic concerns surround the use of venous-arterial extracorporeal membrane oxygenation (VA-ECMO) in elderly patients. Patients requiring VA-ECMO are often in critical condition and the decision to cannulate is time-sensitive. We investigated the relationship between age and VA-ECMO outcomes to better inform this decision. This is a retrospective study of 355 patients placed on VA-ECMO between March 2007 and August 2016 at our institution. Using piecewise modelling, age became associated with in-hospital mortality after 63 years. Based on further analysis with the χ2 statistic maximization, patients were divided into 2 age groups: ≤72 years old [Group Y (Young), n = 310] and >72 years old [Group O (Old), n = 45]. Multivariable logistic regression was performed to identify preoperative predictors of in-hospital mortality. Patients over the age of 72 had a significantly higher prevalence of comorbidities, including coronary disease, previous strokes and chronic kidney disease. Weaning from ECMO was achieved in 76% of Group Y and 47% of Group O (P 72 years as independent predictors of mortality (age >72 years: odds ratio 2.71, 95% confidence interval 1.22-6.00; P = 0.01). VA-ECMO in-hospital mortality is considerable across all age groups. However, age only becomes associated with mortality after 63 years and rises dramatically after 72 years. This study provides useful insight into these time-sensitive decisions for the development of possible practice guidelines. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. CASE REPORT Endovascular embolisation of a cervical spinal AVF ...

    African Journals Online (AJOL)

    Corresponding author: N Mahomed (nasreen.mahomed@wits.ac.za). History. A 38-year-old ... Spinal arterio-venous fistula (AVF) is a rare finding in NF1 and ... 1 may present with a spectrum of vascular lesions affecting the central nervous system .... DSA post embolisation with the catheter tip in left (contra-lateral) vertebral ...

  14. Does topical wound oxygen (TWO2) offer an improved outcome over conventional compression dressings (CCD) in the management of refractory venous ulcers (RVU)? A parallel observational comparative study.

    LENUS (Irish Health Repository)

    Tawfick, W

    2009-07-01

    Topical wound oxygen (TWO(2)) may help wound healing in the management of refractory venous ulcers (RVU). The aim of this study was to measure the effect of TWO(2) on wound healing using the primary end-point of the proportion of ulcers healed at 12 weeks. Secondary end-points were time to full healing, percentage of reduction in ulcer size, pain reduction, recurrence rates and Quality-Adjusted Time Spent Without Symptoms of disease and Toxicity of Treatment (Q-TWiST).

  15. Venous hemodynamic changes in lower limb venous disease

    DEFF Research Database (Denmark)

    Lee, Byung Boong; Nicolaides, Andrew N; Myers, Kenneth

    2016-01-01

    ). Their aim was to confirm or dispel long-held hemodynamic principles and to provide a comprehensive review of venous hemodynamic concepts underlying the pathophysiology of lower limb venous disorders, their usefulness for investigating patients and the relevant hemodynamic changes associated with various...... forms of treatment. Chapter 1 is devoted to basic hemodynamic concepts and normal venous physiology. Chapter 2 presents the mechanism and magnitude of hemodynamic changes in acute deep vein thrombosis indicating their pathophysiological and clinical significance. Chapter 3 describes the hemodynamic...... changes that occur in different classes of chronic venous disease and their relation to the anatomic extent of disease in the macrocirculation and microcirculation. The next four chapters (Chapters 4-7) describe the hemodynamic changes resulting from treatment by compression using different materials...

  16. Diffusive oxygen shunting between vessels in the preglomerular renal vasculature: anatomic observations and computational modeling.

    Science.gov (United States)

    Gardiner, Bruce S; Thompson, Sarah L; Ngo, Jennifer P; Smith, David W; Abdelkader, Amany; Broughton, Brad R S; Bertram, John F; Evans, Roger G

    2012-09-01

    To understand how geometric factors affect arterial-to-venous (AV) oxygen shunting, a mathematical model of diffusive oxygen transport in the renal cortex was developed. Preglomerular vascular geometry was investigated using light microscopy (providing vein shape, AV separation, and capillary density near arteries) and published micro-computed tomography (CT) data (providing vessel size and AV separation; Nordsletten DA, Blackett S, Bentley MD, Ritman EL, Smith NP. IUPS Physiome Project. http://www.physiome.org.nz/publications/nordsletten_blackett_ritman_bentley_smith_2005/folder_contents). A "U-shaped" relationship was observed between the arterial radius and the distance between the arterial and venous lumens. Veins were found to partially wrap around the artery more consistently for larger rather than smaller arteries. Intrarenal arteries were surrounded by an area of fibrous tissue, lacking capillaries, the thickness of which increased from ∼5 μm for the smallest arteries (200-μm diameter). Capillary density was greater near smaller arteries than larger arteries. No capillaries were observed between wrapped AV vessel pairs. The computational model comprised a single AV pair in cross section. Geometric parameters critical in renal oxygen transport were altered according to variations observed by CT and light microscopy. Lumen separation and wrapping of the vein around the artery were found to be the critical geometric factors determining the amount of oxygen shunted between AV pairs. AV oxygen shunting increases both as lumen separation decreases and as the degree of wrapping increases. The model also predicts that capillaries not only deliver oxygen, but can also remove oxygen from the cortical parenchyma close to an AV pair. Thus the presence of oxygen sinks (capillaries or tubules) near arteries would reduce the effectiveness of AV oxygen shunting. Collectively, these data suggest that AV oxygen shunting would be favored in larger vessels common to the

  17. Intra-arterial cis-diamminedichloroplatinum infusion treatment for widespread hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Park, Sung Il; Yang, Hee Chul; Lee, Do Yon; Shim, Yong Woon; Kim, Sang Heum; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1997-01-01

    The purpose of this study is to evaluate the therapeutic efficacy of intra-arterial infusion of Cis-diamminedichloroplatinum (C-DDP) for the treatment of hepatocellular carcinomas with widespread involvement. We retrospectively analyzed 22 patients who between July 1994 and June 1996 had undergone intra-arterial c-DDP infusion therapy for the treatment of hepatocellular carcinomas with widespread involvement. The hepatomas involved both lobes in ten, portal venous obstructions in fourteen, arterio-portal shunts in nine, and arterio-venous shunts in two. Proper hepatic artery was selected for infusion of 100 mg/BSA of C-DDP. The same procedure was repeated every 3 to 4 weeks, and the total number of infusions was 65. On the basis of WHO criteria, response was classified as complete remission, partial remission, stable, or progression of the disease. Six-month and one-year survival rates were estimated, and adverse reactions were evaluated. Although the response rate is not high, intra-arterial C-DDP infusion therapy can be used as an alternative treatment for hepatocellular carcinomas with widespread involvement; adverse reactions are tolerable. (author). 16 refs., 3 figs

  18. The oxygen content of the high-temperature superconducting compound Bi{sub 2+x}Sr{sub 3-y}CayCu{sub 2}O{sub 8+d} with respect to varying Ca and Bi contents

    Energy Technology Data Exchange (ETDEWEB)

    Majewski, P.; Su, H.L.; Aldinger, F. [Max-Planck-Institut fuer Metallforschung, Stuggart (Germany)

    1994-12-31

    The oxygen content of Bi{sub 2+x}Sr{sub 3-y}Ca{sub y}Cu{sub 2}O{sub 8+d} (2212 phase) has been determined as a function of its cation concentration. With increasing Ca and Bi content the oxygen content increases and T{sub c} decreases. The oxygen content of Ca rich 2212 phase increases with decreasing annealing temperatures. The study shows that the T{sub c} of the 2212 phase primarily is controlled by its cation concentration.

  19. Direct venous thrombolysis and venous angioplasty in the upper extremity

    International Nuclear Information System (INIS)

    Hollmann, J.P.; Guenther, R.W.

    1987-01-01

    Venous thromboses of stenoses in the upper extremity are often the result of a compression syndrome of the shoulder girdle, the Paget-von Schroetter syndrome, vascular surgery, space-occupying lesions in the mediastinum or the result of catheterisation. Direct venous thrombolysis and venous angioplasty were performed successfully in six patients. (orig.) [de

  20. Analysis of the vertebral venous system in relation to cerebral venous drainage on MR angiography

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Sohn, Chul Ho; Kim, Gab Chul; Kim, Yong Sun

    2004-01-01

    In the supine position, cerebral venous drainage occurs primarily through the internal jugular veins, as seen on venous phase cerebral angiography. However, in the erect position, the vertebral venous system represents the major alternative pathway of cerebral venous drainage, while outflow through the internal jugular veins is absent or negligible. The purpose of this study is to evaluate the vertebral venous system and its relationship between the surrounding venous structures using magnetic resonance angiography (MRA) in the case of subjects in the supine position. We retrospectively reviewed the results of 65 patients (M:F = 31: 34, mean age 61.6 years) who underwent multi-phase contrast-enhanced carotid MRA. The imaging studies were performed using a 3.0 T MR unit (TR: 5.2, TE: 1.1, FA: 20, 3.8 thickness, EC: 1). We analyzed the appearance and extent of the vertebral venous system (vertebral venous plexus and vertebral artery venous plexus) and the internal jugular vein on the venous phase images. We also evaluated the main drainage pattern of the cerebral venous drainage and the drainage pattern of the vertebral venous system. The visualized vertebral venous system was defined as either poor, vertebral venous plexus dominant, vertebral artery venous plexus dominant or mixed. In the vertebral venous system, the vertebral artery venous plexus was visualized in 54 cases (83%). The appearance of the visualized vertebral artery venous plexus was symmetrical in 39 cases (72%) and asymmetrical in 15 cases (28%). The extent of the visualized vertebral artery venous plexus was partial in 26 cases (48%) and complete in 28 cases (52%). The vertebral venous plexus was visualized in 62 cases (95%). The appearance of the visualized vertebral artery venous plexus was symmetrical in 43 cases (69%) and asymmetrical in 19 cases (31%). The extent of the visualized vertebral artery venous plexus was partial in 35 cases (56%) and complete in 27 cases (44%). The appearance of the

  1. Evaluation of Optimum Moisture Content for Composting of Beef Manure and Bedding Material Mixtures Using Oxygen Uptake Measurement

    Directory of Open Access Journals (Sweden)

    Eunjong Kim

    2016-05-01

    Full Text Available Moisture content influences physiological characteristics of microbes and physical structure of solid matrices during composting of animal manure. If moisture content is maintained at a proper level, aerobic microorganisms show more active oxygen consumption during composting due to increased microbial activity. In this study, optimum moisture levels for composting of two bedding materials (sawdust, rice hull and two different mixtures of bedding and beef manure (BS, Beef cattle manure+sawdust; BR, Beef cattle manure+rice hull were determined based on oxygen uptake rate measured by a pressure sensor method. A broad range of oxygen uptake rates (0.3 to 33.3 mg O2/g VS d were monitored as a function of moisture level and composting feedstock type. The maximum oxygen consumption of each material was observed near the saturated condition, which ranged from 75% to 98% of water holding capacity. The optimum moisture content of BS and BR were 70% and 57% on a wet basis, respectively. Although BS’s optimum moisture content was near saturated state, its free air space kept a favorable level (above 30% for aerobic composting due to the sawdust’s coarse particle size and bulking effect.

  2. Evaluation of Optimum Moisture Content for Composting of Beef Manure and Bedding Material Mixtures Using Oxygen Uptake Measurement.

    Science.gov (United States)

    Kim, Eunjong; Lee, Dong-Hyun; Won, Seunggun; Ahn, Heekwon

    2016-05-01

    Moisture content influences physiological characteristics of microbes and physical structure of solid matrices during composting of animal manure. If moisture content is maintained at a proper level, aerobic microorganisms show more active oxygen consumption during composting due to increased microbial activity. In this study, optimum moisture levels for composting of two bedding materials (sawdust, rice hull) and two different mixtures of bedding and beef manure (BS, Beef cattle manure+sawdust; BR, Beef cattle manure+rice hull) were determined based on oxygen uptake rate measured by a pressure sensor method. A broad range of oxygen uptake rates (0.3 to 33.3 mg O2/g VS d) were monitored as a function of moisture level and composting feedstock type. The maximum oxygen consumption of each material was observed near the saturated condition, which ranged from 75% to 98% of water holding capacity. The optimum moisture content of BS and BR were 70% and 57% on a wet basis, respectively. Although BS's optimum moisture content was near saturated state, its free air space kept a favorable level (above 30%) for aerobic composting due to the sawdust's coarse particle size and bulking effect.

  3. Suicide by severing the arterio-venous subclavian dialysis catheter.

    Science.gov (United States)

    Edirisinghe, P A S; Busuttil, A

    2006-02-01

    Haemodialysis access is an essential requirement for haemodialysis treatment in end-stage renal disease. The common forms are arteriovenous fistula (AVF) and arteriovenous grafts in ante-cubital fossa, forearm and upper thigh. Sometimes temporary or immediate access is created via a subclavian catheter or internal jugular catheter. This report is on a 79-year-old man who was suffering from chronic renal failure with a non-functional peripheral AVF; he was being dialysed through a permanent subclavian catheter and he became depressed due to continuing deterioration of his health. He used the easily accessible haemodialysis site as the method of suicide by cutting the tube that connected with the main vessel in his chest and bled to death. This highlights the requirement to assess carefully the patient's mental state in those on chronic haemodialysis, even though very few similar fatal cases have been previously reported.

  4. Liquid breathing - Prevention of pulmonary arterial-venous shunting during acceleration.

    Science.gov (United States)

    Sass, D. J.; Ritman, E. L.; Caskey, P. E.; Banchero, N.; Wood, E. H.

    1972-01-01

    Dependent pulmonary atelectasis, arterial-venous shunting, and downward displacement of the heart caused by the gravitational-inertial force environment were prevented in dogs breathing oxygenated liquid fluorocarbon in a whole-body water-immersion respirator. Partial closure of the major airways during part of the expiratory phase of liquid respiration was a significant problem initially but was minimized in subsequent studies.

  5. Constriction of collateral arteries induced by "head-up tilt" in patients with occlusive arterial disease of the legs

    DEFF Research Database (Denmark)

    Agerskov, K; Henriksen, O; Tønnesen, K H

    1981-01-01

    The effect of head-up tilt on leg blood flow and segmental arterial blood pressures was studied in 21 patients with occlusion or severe stenosis of the common or superficial femoral artery. Arterial pressure was measured directly in the brachial artery, common femoral artery and popliteal artery....... Relative change in blood flow in the leg during tilt was estimated by changes in arterio-venous oxygen differences and by the indicator dilution technique in nine patients. Head-up tilt caused a decrease in leg blood flow of 36% corresponding to an increase in total vascular resistance of 57%. Tilt did...... not change the pressure gradient from femoral to popliteal artery in the patients with occlusion of the superficial femoral artery, indicating that the flow resistance offered by the collateral arteries had increased. In a bilateral sympathectomised patient the increase in collateral resistance was almost...

  6. THE SUCCESSFUL TREATMENT OF A PERIPHERAL VENO-VENOUS EXTRACORPOREAL MEMBRANE OXYGENATION FOR SEVERE ACUTE RESPIRATORY FAILURE IN THE EARLY PERIOD AFTER ADULT LIVER TRANSPLANTATION

    Directory of Open Access Journals (Sweden)

    V. N. Poptsov

    2014-01-01

    Full Text Available Aim: of our clinical study was to present own experience of veno-venous extracorporeal membrane oxygenation (VV ECMO for the treatment of an adult patient (female, 28 yrs, 150 cm, 35 kg with acute respiratory distress syndrome (ARDS in the early period after liver transplantation against satisfactory liver graft function. Materials and methods. Double-lumen cannula 22 F was placed percutaneously in the right internal jugular vein. The ext- racorporeal contour reduced in length and the polymethylpeptene oxygenator (priming volume 175 ml were also. Results. In 1 hour after the beginning of VV ECMO, we registered the noted improvement of arterial blood gas and acid-base balance (regress of respiratory acidosis, improvement of arterial oxygenation which allowed us to use the «protective» mode of mechanical ventilation. Improvement of gas exchange and regress of clinical and radiological manifestations of ARDS allowed for VV ECMO weaning and decannulation on day 7. The patient was discharged from ICU and then from our Centre to a homestay respectively on the 9th and 16th day after VV ECMO weaning with the satisfactory liver graft and lungs function. Conclusion. VV ECMO can be successfully applied to correct the life-threatening acute respiratory failure in the early period after liver transplantation. 

  7. Effect of temperature, of oxygen content and the downstream effect on corrosion rate of structural materials in liquid sodium

    International Nuclear Information System (INIS)

    Ilincev, G.

    1988-01-01

    The effects were experimentally tested of temperature and of oxygen content on the corrosion rate of structural materials in liquid sodium and on reducing the corrosion rate down the sodium stream. The results of the experiments are shown in graphs and tables and are discussed in detail. The duration of all tests was standard 1,000 hours. The test parameters were set such as to determine the effect of temperature on corrosion of a quantity of various materials in sodium with a low oxygen content (1.2 to 2 ppm) at temperatures of 500 to 800 degC and in sodium with a high oxygen content (345 ppm) at temperatures of 500 to 700 degC. More experiments served the determination of the effect of a different oxygen content varying between 1.2 and 2 ppm at a constant temperature of 600 degC. The materials being tested included main structural materials used for fast reactor construction and materials allowing to establish the effect of main alloying elements on their corrosion in liquid sodium of different temperatures and purity grades. The relationships showing the effects of temperature and oxygen content in sodium on the rate of corrosion of various structural materials in hot parts of the installation and on the reduction in the rate of corrosion downstream due to sodium saturation with corrosion products were constructed using the experimental results. (Z.M.). 15 figs., 2 tabs., 7 refs

  8. ExtraCorporeal Membrane Oxygenation in Newborns. Implications for Brain and Lung.

    NARCIS (Netherlands)

    Heyst, A.F.J. van

    2004-01-01

    Extracorporeal membrane oxygenation (ECMO) is a rescue treatment for newborns with severe respiratory insufficiency. In veno-arterial ECMO, venous blood is drained from the right atrium, oxygenated in an artificial lung and reinfused in the aorta. For vascular access the right internal jugular vein

  9. Optical characterization of surface and interface oxygen content in YBa2Cu3O/sub x/

    International Nuclear Information System (INIS)

    Kelly, M.K.; Chan, S.; Jenkin, K. II; Aspnes, D.E.; Barboux, P.; Tarascon, J.

    1988-01-01

    Because YBa 2 Cu 3 O/sub x/ exists over a range of oxygen content and low oxygen material is nonsuperconducting, it is important to be able to measure and control this parameter for application purposes. We present an optical technique for determining oxygen loss at surfaces and interfaces, where processing and contacts with other materials may affect composition and where usual techniques are insensitive. Using a strong absorption feature at 4.1 eV which appears at low oxygen composition, we find that overlayers of Al and In remove oxygen from YBa 2 Cu 3 O/sub x/, but Ag, Au, and room-temperature exposure to moderate vacuum do not

  10. Swimming performance, venous oxygen tension and cardiac performance of coronary-ligated rainbow trout, Oncorhynchus mykiss, exposed to progressive hypoxia

    DEFF Research Database (Denmark)

    Steffensen, J F; Farrell, A P

    1998-01-01

    We performed in vivo studies to examine the idea that cardiac work is impaired in rainbow trout (Oncorhynchus mykiss) below a certain venous PO2 threshold. We hypothesized that coronary-ligated fish, swimming continuously at a reasonably high water velocity (1.5 body lengths x s(-1)) and exposed...... to progressive hypoxia, would fatigue at higher venous PO2 and ambient water PO2 compared with sham-operated fish. However, we found that both the lowest venous PO2 that supported hypoxic swimming (9.9 torr for coronary-ligated fish and 11.1 torr for sham-operated fish) and the venous PO2 at fatigue (7.8 torr...... and 8.6 torr, respectively) were the same for coronary-ligated and sham-operated fish. Also, both groups quit swimming at the same water PO2 heart rate and hematocrit. Nevertheless, significant differences in cardiac performance did exist between the two groups. Whereas ventral aortic blood pressure...

  11. Relationship between retinal blood flow and arterial oxygen.

    Science.gov (United States)

    Cheng, Richard W; Yusof, Firdaus; Tsui, Edmund; Jong, Monica; Duffin, James; Flanagan, John G; Fisher, Joseph A; Hudson, Chris

    2016-02-01

    Vascular reactivity, the response of the vessels to a vasoactive stimulus such as hypoxia and hyperoxia, can be used to assess the vascular range of adjustment in which the vessels are able to compensate for changes in PO2. Previous studies in the retina have not accurately quantified retinal vascular responses and precisely targeted multiple PaO2 stimuli at the same time as controlling the level of carbon dioxide, thus precluding them from modelling the relationship between retinal blood flow and oxygen. The present study modelled the relationship between retinal blood flow and PaO2, showing them to be a combined linear and hyperbolic function. This model demonstrates that the resting tonus of the vessels is at the mid-point and that they have great vascular range of adjustment, compensating for decreases in oxygen above a PETCO2 of 32-37 mmHg but being limited below this threshold. Retinal blood flow (RBF) increases in response to a reduction in oxygen (hypoxia) but decreases in response to increased oxygen (hyperoxia). However, the relationship between blood flow and the arterial partial pressure of oxygen has not been quantified and modelled in the retina, particularly in the vascular reserve and resting tonus of the vessels. The present study aimed to determine the limitations of the retinal vasculature by modelling the relationship between RBF and oxygen. Retinal vascular responses were measured in 13 subjects for eight different blood gas conditions, with the end-tidal partial pressure of oxygen (PETCO2) ranging from 40-500 mmHg. Retinal vascular response measurements were repeated twice; using the Canon laser blood flowmeter (Canon Inc., Tokyo, Japan) during the first visit and using Doppler spectral domain optical coherence tomography during the second visit. We determined that the relationship between RBF and PaO2 can be modelled as a combination of hyperbolic and linear functions. We concluded that RBF compensated for decreases in arterial oxygen content

  12. [Values of mixed venous oxygen saturation and difference of mixed venous-arterial partial pressure of carbon dioxide in monitoring of oxygen metabolism and treatment after open-heart operation].

    Science.gov (United States)

    Pan, Chuanliang; Zhang, Haiying; Liu, Jianping

    2014-10-01

    To explore the clinic values of early goal directed treatment (EGDT) with the target of mixed venous oxygen saturation (SvO₂) and difference of mixed venous-arterial partial pressure of carbon dioxide (Pv-aCO₂) in monitoring of oxygen metabolism and treatment for patients post open-heart operation. A prospective study was conducted. The adult patients admitted to Third People's Hospital of Chengdu from December 2011 to March 2014 with SvO₂2 mmol/L when admitted in intensive care unit (ICU) were selected on whom elective open-heart operation and pulmonary artery catheter examination were done. All patients received EGDT with the target of SvO₂≥0.65 and Pv-aCO₂<6 mmHg (1 mmHg=0.133 kPa) and were divided into three groups by the values of SvO₂and Pv-aCO₂at 6-hour after ICU admission: A group with SvO₂≥0.65 and Pv-aCO₂<6 mmHg, B group with SvO₂≥0.65 and Pv-aCO₂≥6 mmHg, and C group with SvO₂<0.65. Then the changes and prognosis of the patients in different groups were observed. 103 cases were included, 44 in A group, 31 in B group and 28 in C group. The acute physiology and chronic health evaluation II (APACHEII) score in group A were significantly lower than that in group B or C at 6, 24, 48 and 72 hours (T6, T24, T48, T72) of ICU admission (T6: 11.4 ± 5.8 vs. 13.9 ± 5.4, 13.7 ± 6.4; T24: 8.8 ± 3.7 vs. 10.8 ± 4.8, 11.8 ± 5.4; T48: 8.7 ± 4.1 vs. 9.6 ± 4.2, 10.2 ± 5.1; T72: 7.5 ± 3.4 vs. 8.6 ± 2.9, 9.2 ± 4.2, all P<0.05), and the sequential organ failure assessment (SOFA) showed the same tendency (T6: 6.5 ± 4.3 vs. 8.0 ± 3.8, 9.1 ± 4.5; T24: 6.6 ±3.6 vs. 8.6 ± 3.9, 8.5 ± 3.3; T48: 5.2 ± 3.4 vs. 7.0 ± 3.6, 7.6 ± 5.1; T72: 4.6 ± 2.4 vs. 5.8 ± 2.5, 6.8 ± 3.5, all P<0.05). The values of blood lactic acid (mmol/L) in group A and B were significant lower than that in group C at T6, T24, T48 and T72 (T6: 1.60 ± 0.95, 2.20 ± 1.02 vs. 2.55 ± 1.39; T24: 2.26 ± 1.26, 2.70 ± 1.36 vs. 3.34 ± 2.36; T48: 2.01 ± 1.15, 2.17

  13. Dissolved oxygen content as an index of water quality in San Vicente Bay, Chile (36 degrees 45'S).

    Science.gov (United States)

    Rudolph, Anny; Ahumada, Ramón; Pérez, Claudio

    2002-08-01

    The present report describes some effects of industrial and municipal effluents on the waters of San Vicente Bay. Analyses of the main substances contained in the fishing industry effluent suggest rating criteria based on the oxygen saturation of the water as an assessment of organic pollution. Six cruises were carried out throughout the Bay, from June to December 1996. Water samples were analyzed for dissolved oxygen, oil and grease content, and sediment samples for organic matter content. Water parameters (salinity, temperature) were used to characterize the Bay's hydrography, and to calculate values for oxygen saturation. The measurements demonstrated a local broad range of oxygen deficit, with a maximum of 45% in the winter to 95% in the spring. In November more than 65% of the Bay's area showed oxygen deficits greater than 40%. Organic matter was unusually high in sediments along the northern sector of the Bay. The results suggest that the oxygen depletion was a representative parameter for establishing a relative scale of water quality in this Bay.

  14. Reduced Cerebral Oxygen Content in the DG and SVZ In Situ Promotes Neurogenesis in the Adult Rat Brain In Vivo.

    Directory of Open Access Journals (Sweden)

    Kuan Zhang

    Full Text Available Neurogenesis in the adult brain occurs mainly within two neurogenic structures, the dentate gyrus (DG of the hippocampus and the sub-ventricular zone (SVZ of the forebrain. It has been reported that mild hypoxia promoted the proliferation of Neural Stem Cells (NSCsin vitro. Our previous study further demonstrated that an external hypoxic environment stimulated neurogenesis in the adult rat brain in vivo. However, it remains unknown how external hypoxic environments affect the oxygen content in the brain and result in neurogenesis. Here we use an optical fiber luminescent oxygen sensor to detect the oxygen content in the adult rat brain in situ under normoxia and hypoxia. We found that the distribution of oxygen in cerebral regions is spatiotemporally heterogeneous. The Po2 values in the ventricles (45∼50 Torr and DG (approximately 10 Torr were much higher than those of other parts of the brain, such as the cortex and thalamus (approximately 2 Torr. Interestingly, our in vivo studies showed that an external hypoxic environment could change the intrinsic oxygen content in brain tissues, notably reducing oxygen levels in both the DG and SVZ, the major sites of adult neurogenesis. Furthermore, the hypoxic environment also increased the expression of HIF-1α and VEGF, two factors that have been reported to regulate neurogenesis, within the DG and SVZ. Thus, we have demonstrated that reducing the oxygen content of the external environment decreased Po2 levels in the DG and SVZ. This reduced oxygen level in the DG and SVZ might be the main mechanism triggering neurogenesis in the adult brain. More importantly, we speculate that varying oxygen levels may be the physiological basis of the regionally restricted neurogenesis in the adult brain.

  15. Brain oxygen saturation assessment in neonates using T2-prepared blood imaging of oxygen saturation and near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra Ma

    2017-01-01

    saturation in the sagittal sinus (R(2 )= 0.49, p = 0.023), but no significant correlations could be demonstrated with frontal and whole brain cerebral blood flow. These results suggest that measuring oxygen saturation by T2-prepared blood imaging of oxygen saturation is feasible, even in neonates. Strong...... sinus. A strong linear relation was found between the oxygen saturation measured by magnetic resonance imaging and the oxygen saturation measured by near-infrared spectroscopy (R(2 )= 0.64, p ..., and magnetic resonance imaging measures of frontal cerebral blood flow, whole brain cerebral blood flow and venous oxygen saturation in the sagittal sinus (R(2 )= 0.71, 0.50, 0.65; p 

  16. [Fistulae or catheter for elderly who start hemodialysis without permanent vascular access?].

    Science.gov (United States)

    García Cortés, Ma J; Viedma, G; Sánchez Perales, M C; Borrego, F J; Borrego, J; Pérez del Barrio, P; Gil Cunquero, J M; Liébana, A; Pérez Bañasco, V

    2005-01-01

    Autologous access is the best vascular access for dialysis also in older patients and it should be mature when patient needs hemodialysis. It is not always possible. Surgeon availability and demographic characteristics of patients (age, diabetes, vascular disease...) are factors that determine primary vascular access. To analyse outcome and vascular access complications in elderly who start hemodialysis without vascular access. All patients older than 75 years who initiated hemodialysis without vascular access between January 2000 and June 2002 were included, They were divided en two groups depending on primary vascular access. GI: arterio-venous fistulae. GIIl: Tunnelled cuffed catheter. Epidemiological and analytical data, vascular access complications related, as well as patient and first permanent vascular access survival from their inclusion in dialysis up to December 2002 were analysed and compared in both groups. 32 patients were studied. GI: n = 17 (4 men) and GIIl: n =1 5 (8 men), age: 79.9 +/- 3.8 and 81.7 +/- 4 years respectively (ns). There were no differences in sex and comorbidity (diabetes, ischemic heart disease, peripheral vascular disease and hypertension). It took GI 3 months to get a permanent vascular access suitable for using, while it took GIIl 1.3 months (p catheters was higher in GI (3.35 vs 1.87 p central venous thrombosis happen in GI (I: 25 CVT/100 patients-year) vs 30% in GIIl (I = 14.4/100 patients-year) (ns). No significant differences neither in bleeding (66.7% vs 33.3%) nor ischemia (75% vs 25%) were found. Dialysis dose (Kt/V) as well as anaemia degree were similar in both groups. Permanent vascular access survival after 2 years was 45.8% in GI and 24% in GII (ns). Patient survival was similar in GI and GII (72% vs 51% ns). Elderly who start hemodialysis without vascular access took longer to get a suitable permanent vascular access when arterio-venous fistulae is placed than with a tunnelled cuffed hemodialysis catheter. As a

  17. Venous Ulcers

    Science.gov (United States)

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  18. Lactate, endothelin, and central venous oxygen saturation as predictors of mortality in patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Poonam Malhotra Kapoor

    2016-01-01

    Full Text Available Background: Lactate and central venous oxygen saturation (ScVO2 are well known biomarkers for adequacy of tissue oxygenation. Endothelin, an inflammatory marker has been associated with patient′s nutritional status and degree of cyanosis. The aim of this study was to explore the hypothesis that lactate, ScVO2 and endothelin before induction may be predictive of mortality in pediatric cardiac surgery. Methods: We conducted a prospective observational study of 150 pediatric (6 months to 12 years patients who were posted for intracardiac repair for tetralogy of fallot and measured lactate, ScVO2 and endothelin before induction (T1, 20 minutes after protamine administration (T2 and 24 hours after admission to ICU (T3. Results: Preinduction lactate and endothelin levels were found to predict mortality in patients of tetralogy of fallot with an odds ratio of 6.020 (95% CI 2.111-17.168 and 1.292(95% CI 1.091-1.531 respectively. In the ROC curve analysis for lactate at T1, the AUC was 0.713 (95% CI 0.526-0.899 P = 0.019. At the cutoff value of 1.750mmol/lt, the sensitivity and specificity for the prediction of mortality was 63.6% and 65.5%, respectively. For endothelin at T1, the AUC was 0.699 (95% CI 0.516-0.883, P = 0.028 and the cutoff value was ≤2.50 (sensitivity, 63.6%; specificity, 58.3 %. ScVO2 (odds ratio 0.85 at all three time intervals, suggested that improving ScVO2 can lead to 15% reduction in mortality. Conclusions: Lactate, ScVO2 and endothelin all showed association with mortality with lactate having the maximum prediction. Lactate was found to be an independent, reliable and cost-effective measure of prediction of mortality in patients with tetralogy of fallot.

  19. A case of intralobar pulmonary sequestration

    International Nuclear Information System (INIS)

    Misawa, Takuo; Hongo, Minoru; Okubo, Shinichi; Yamada, Hiroyoshi; Matsuoka, Ken; Soga, Naoko; Kono, Jun; Kusama, Shozo

    1985-01-01

    A 57-year-old female was admitted to our hospital, complaining of hemoptysis. On auscultation, moist rales were audible at the lower portion of left posterior chest. Plain chest roentgenogram showed a round shadow in the left lower lung field. Computed tomography with contrast enhancement revealed an abnormal structure which was contiguous to a strand structure. Dynamic scanning demonstrated opacification of the strand structure and that of the greater part of the abnormal structure during peak opacification of the descending aorta. A part of the abnormal structure was opacified during the same phase as the opacification of the right ventricle and pulmonary artery. A diagnosis of intralobar pulmonary sequestration associated with pulmonary arterio-venous malformation was confirmed by thoracic aortography and left pulmonary arteriography. The hemoptysis was found to be caused by chronic bronchitis. It was emphasized that dynamic computed tomography is very useful to diagnose intralobar pulmonary sequestration and to assess the presence of pulmonary arterio-venous malformation. In addition, it is of particular interest that this case cannot be assigned to any category of Pryce's classification although it resembles both type I and IV. (author)

  20. CLINICAL APPROACH TO HEREDITARY HEMORRHAGIC TELANGIECTASIA

    Directory of Open Access Journals (Sweden)

    Mary Hachmeriyan

    2013-11-01

    Full Text Available Background: Hereditary hemorrhagic telangiectasia (HHT or Rendu-Osler-Weber disease is a rare syndrome, inherited as an autosomal dominant trait with incidence of 1/10000. The clinical manifestations are due to vascular malformations and predisposition to hemorrhages in different organs, the leading symptom being recurrent epistaxis. If diagnosed with HHT, the patient and his relatives and especially children have to be screened for occult vascular malformations.Case report: A 30 years old woman was treated for cerebral stroke, epistaxis, anemia, arterio-venous malformations for over 6 months. Only at this point she was diagnosed with HHT, after noticing the typical mucosal changes. Focused family history revealed symptoms of HHT in her only child, her father, aunt and two cousins The child was screened for occult vascular malformations – attainment of the nasal mucosa, lungs, gastrointestinal system, liver and brain. Pulmonary and gastrointestinal arterio-venous malformations were proven.Conclusion: Any case of recurrent epistaxis should be evaluated for HHT. After confirmation of the diagnosis every patient and close relatives have to be screened for attainment of other organs and followed up in order to prevent severe life threatening complications.

  1. Factors associated with blood oxygen partial pressure and carbon dioxide partial pressure regulation during respiratory extracorporeal membrane oxygenation support: data from a swine model.

    Science.gov (United States)

    Park, Marcelo; Mendes, Pedro Vitale; Costa, Eduardo Leite Vieira; Barbosa, Edzangela Vasconcelos Santos; Hirota, Adriana Sayuri; Azevedo, Luciano Cesar Pontes

    2016-01-01

    The aim of this study was to explore the factors associated with blood oxygen partial pressure and carbon dioxide partial pressure. The factors associated with oxygen - and carbon dioxide regulation were investigated in an apneic pig model under veno-venous extracorporeal membrane oxygenation support. A predefined sequence of blood and sweep flows was tested. Oxygenation was mainly associated with extracorporeal membrane oxygenation blood flow (beta coefficient = 0.036mmHg/mL/min), cardiac output (beta coefficient = -11.970mmHg/L/min) and pulmonary shunting (beta coefficient = -0.232mmHg/%). Furthermore, the initial oxygen partial pressure and carbon dioxide partial pressure measurements were also associated with oxygenation, with beta coefficients of 0.160 and 0.442mmHg/mmHg, respectively. Carbon dioxide partial pressure was associated with cardiac output (beta coefficient = 3.578mmHg/L/min), sweep gas flow (beta coefficient = -2.635mmHg/L/min), temperature (beta coefficient = 4.514mmHg/ºC), initial pH (beta coefficient = -66.065mmHg/0.01 unit) and hemoglobin (beta coefficient = 6.635mmHg/g/dL). In conclusion, elevations in blood and sweep gas flows in an apneic veno-venous extracorporeal membrane oxygenation model resulted in an increase in oxygen partial pressure and a reduction in carbon dioxide partial pressure 2, respectively. Furthermore, without the possibility of causal inference, oxygen partial pressure was negatively associated with pulmonary shunting and cardiac output, and carbon dioxide partial pressure was positively associated with cardiac output, core temperature and initial hemoglobin.

  2. Fingertip Reconstruction Using Free Toe Tissue Transfer Without Venous Anastomosis

    Directory of Open Access Journals (Sweden)

    Won Young Yoon

    2012-09-01

    Full Text Available BackgroundThis study was designed to introduce the feasibility of toe tissue transfer without venous outflow for fingertip reconstruction.MethodsFive cases of fingertip defects were treated successfully with this method. Four cases were traumatic fingertip defects, and one case was a hook-nail deformity. The lateral pulp of a great toe or medioinferior portion of a second toe was used as the donor site. An arterial pedicle was dissected only within the digit and anastomosis was performed within 2 cm around the defect margin. The digital nerve was repaired simultaneously. No additional dissection of the dorsal or volar pulp vein was performed in either the donor or recipient sites. Other surgical procedures were performed following conventional techniques. Postoperative venous congestion was monitored with pulp temperature, color, and degree of tissue oxygen saturation. Venous congestion was decompressed with a needle-puncture method intermittently, but did not require continuous external bleeding for salvage.ResultsVenous congestion was observed in all the flaps, but improved within 3 or 4 days postoperatively. The flap size was from 1.5×1.5 cm2 to 2.0×3.0 cm2. The mean surgical time was 2 hours and 20 minutes. A needle puncture was carried out every 2 hours during the first postoperative day, and then every 4 hours thereafter. The amount of blood loss during each puncture procedure was less than 0.2 mL. In the long-term follow-up, no flap atrophy was observed.ConclusionsWhen used properly, the free toe tissue transfer without venous anastomosis method can be a treatment option for small defects on the fingertip area.

  3. Filterability of corrosion products formed between carbon steel and water. Influence of temperature and oxygen content

    International Nuclear Information System (INIS)

    Kelen, T.; Falk, I.

    1975-09-01

    A laboratory investigation has been made for the purpose of studying the influence of temperature and oxygen content on the filterability of corrosion products formed between carbon-steel and water. The experiments were performed in a high temperature loop where the water is initially heated in a pre-heater, then cooled and finally filtered. The corrosion products were transferred to thewater from a carbon-steel surface that had previously been neutron activated and the amount of iron present was determined from measurements of the γ-radiation emitted by Fe-59. Filterability was then computed as the ratio between the total amount of iron in the water phase and the amount of iron retained on the filter. The investigation covers a series of experiments at filtering temperatures of 20, 90 and 160 dec G, pre-heater temperatures up to 300 deg C and oxygen contents of 10 and 300 ppb O 2 . In addition the extent of iron deposition in the pre-heater and heat regulator has been determined after each series of experiments. Filterability exhibited a pronounced dependence upon both the filter and pre-heater temperatures and also upon the oxygen content. Among the conclusions to which the results lead is the observation that a strict comparison of filterability values for the fraction of corrosion products in cooled water samples is impossible when these are taken from 1) different sections of a high temperature system 2) a single sampling point while the system is being run up 3) two separate systems (e.g. steam boilers) operated at different temperatures 4) two separate systems operated at different oxygen contents. It accordingly appears advizable to restrict the use of cold-filtered samples from conventional steam-raising plants to the comparison of values relating to a single sampling point under constant operating conditions. (author)

  4. Microvascular oxygen pressure in the pig intestine during haemorrhagic shock and resuscitation

    NARCIS (Netherlands)

    Sinaasappel, M.; van Iterson, M.; Ince, C.

    1999-01-01

    1. The aim of this study was to investigate the relation between microvascular and venous oxygen pressures during haemorrhagic shock and resuscitation in the pig intestine. To this end microvascular PO2 (microPO2) was measured by quenching of Pd-porphyrin phosphorescence by oxygen and validated for

  5. Medical management of venous ulcers.

    Science.gov (United States)

    Pascarella, Luigi; Shortell, Cynthia K

    2015-03-01

    Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Diagnosis of venous disorders

    International Nuclear Information System (INIS)

    Minar, E.

    1993-01-01

    Limited accuracy in the clinic diagnosis of deep vein thrombosis (VT) makes such diagnostic tests such as duplex sonography or venography necessary. Exact information on the age and extent of the thrombus are necessary for the clinician to optimize the therapeutric management. The correct diagnosis of calf vein thrombosis and of recurrent VT in patients with postphlebitis changes also has implications for treatment. After exclusion of thrombosis, the radiologist should evaluate the leg for other possible causes of symptoms besides VT. Investigation of the venous sytem also has a role in the diagnosis in patients with suspected pulmonary embolism. In patients with chronic venous insuffficiency the deep venous system should assessed for patency and venous valve function. The superficial veins should be differentiated in segments with sufficient or insufficient venous valves, and it is also necessary to look for insufficiency of the perforrating veins. In patients with superficial phlebitis there is risk of propagation into the deep venous system. (orig.) [de

  7. Brain venous pathologies: MRI findings

    International Nuclear Information System (INIS)

    Salvatico, Rosana; Gonzalez, Alejandro; Yanez, Paulina; Romero, Carlos; Trejo, Mariano; Lambre, Hector

    2006-01-01

    Purpose: To describe MRI findings of the different brain venous pathologies. Material and Methods: Between January 2002 and March 2004, 18 patients were studied 10 males and 8 females between 6 and 63 years old; with different brain venous pathologies. In all cases brain MRI were performed including morphological sequences with and without gadolinium injection and angiographic venous sequences. Results: 10 venous occlusions were found, 6 venous angiomas, and 2 presented varices secondary to arteriovenous dural fistula. Conclusion: Brain venous pathologies can appear in many different clinical contexts, with different prognosis and treatment. In all the cases brain MRI was the best imaging study to disclose typical morphologic abnormalities. (author) [es

  8. Cerebral venous angiomas

    International Nuclear Information System (INIS)

    Agnoli, A.L.; Hildebrandt, G.

    1985-01-01

    Clinical symptoms and radiological signs in 15 patients with cerebral venous malformations are presented and the diagnostic problems discussed. The circulation time in combination with cerebral malformations and angiomas of the scalp are described. CT findings in cases of venous malformations of the brain stem are evaluated. Spot-like enhancement, as well as sharply demarcated round shaped enhancement are characteristic for venous angiomas. Cavernous angiomas usually present as homogenous or inhomogenous round shaped enhanced areas. (Author)

  9. Venous ulcers -- self-care

    Science.gov (United States)

    ... surgery to improve blood flow through your veins. Prevention If you are at risk for venous ulcers, take the steps listed above under Wound Care. ... weight if you are overweight. Manage your blood pressure and cholesterol levels. ... Venous leg ulcers - self-care; Venous insufficiency ulcers - self-care; Stasis ...

  10. The predictive value of the radionuclide fistulogram (RnF) and its perioperative evaluation in arterio-venous fistulae (AVf) malfunction

    Energy Technology Data Exchange (ETDEWEB)

    Seo, I.S.; Sy, W.M.; Heneghan, W.; Manoli, A.

    1985-05-01

    The predictive value of the RnF in AVf malfunction was determined in 56 hemodialysis patients (77 studies). Two second dynamic images (qualitative) and concurrent 64 x 64 byte mode acquisition with .5 sec/frame for 1 min. (quantitative) were obtained following the administration of 15-20 mCi of Tc99m compounds (MDP or Tc04) into or near the AVf. Fourteen patients with clinical suspicion of AVf malfunction were referred for RnF. Eleven (78.6%) were abnormal and 3 were normal, based on previously established qualitative (collaterals, back flow and/or stenosis) and quantitative (S/sub 1//S/sub 2/<10%) criteria. Confirmatory contrast fistulogram (CnF) and surgical repair were done in 8/11. In three with normal studies, one had soft tissue abscesses near the venous orifice, another was attributed to malposition of needles at hemodialysis and no cause was apparent in the third. In 42 clinically unsuspected patients who were referred for other studies (bone scintigraphy and MUGA), nine (21.9%) had abnormal findings. Within three months, surgical repairs were made in four after CnF's confirmed AVf malfunction. The remaining five later developed signs of malfunction. 9 of 12 patients with surgical repairs had post surgical studies: 5 were normal while 2 remained abnormal even after a second surgical attempt; 2 had no follow up studies but were clinically asymptomatic. RnF is a simple benign imaging procedure with a high predictive value in documenting AVf malfunction in both symptomatic (78.9%) and in otherwise clinically unsuspected (21.9%) patients. Excellent clinical correlation in patients with surgical repairs is achieved.

  11. Models of the venous system

    DEFF Research Database (Denmark)

    Mehlsen, J

    2000-01-01

    Cardiac output is largely controlled by venous return, the driving force of which is the energy remaining at the postcapillary venous site. This force is influenced by forces acting close to the right atrium, and internally or externally upon the veins along their course. Analogue models of the v......Cardiac output is largely controlled by venous return, the driving force of which is the energy remaining at the postcapillary venous site. This force is influenced by forces acting close to the right atrium, and internally or externally upon the veins along their course. Analogue models...... of the venous system require at least three elements: a resistor, a capacitor and an inductor, with the latter being of more importance in the venous than in the arterial system. Non-linearities must be considered in pressure/flow relations in the small venules, during venous collapse, or low flow conditions...

  12. Analysis of oxygen content in steel by means of 14 MeV neutrons

    International Nuclear Information System (INIS)

    Chuang, L.S.; Wong, K.C.; Chiu, W.Y.

    1975-01-01

    A sealed-tube type 14 MeV neutron generator with maximum neutron output of 10 11 n/sec, incorporating a pneumatic sample transfer system of single-tube type and with a single rotation of the sample during neutron irradiation, is used to develop a method suitable for routine work in industrial applications. A pulse shape analyser system incorporating an organic scintillation detector is used for monitoring neutron flux level during the neutron irradiation of the sample. Polyethylene, of oxygen content 163 ppm determined by comparison with lucite, is used as the steel sample carrier. A 3 x 3 in. NaI(Tl) crystal is used with a single channel analyser to count the 6.1 and 7.1 MeV gamma rays emitted from 16 N as a result of the reaction 16 O(n,p) 16 N. As the present activation analysis makes use of the comparison method, a steel-mylar standard made of layered steel and mylar discs is prepared and a calibration curve constructed. A method of correcting the oxygen contribution in the polyethylene sample carrier is devised and the content of oxygen in the steel standard is determined. A survey of neutron flux distribution is also attempted and it is found that nearly symmetrical distribution of the flux, about the centre of the sample carrier which is placed with its axis in parallel to the plane of the disc-shaped target of the neutron-generating tube, is far from being flat. (Auth.)

  13. Sildenafil does not influence hepatic venous pressure gradient in patients with cirrhosis

    DEFF Research Database (Denmark)

    Clemmesen, Jens-Otto; Giraldi, Annamaria; Ott, Peter

    2008-01-01

    AIM: To investigate if sildenafil increases splanchnic blood flow and changes the hepatic venous pressure gradient (HVPG) in patients with cirrhosis. Phosphodiesterase type-5 inhibitors are valuable in the treatment of erectile dysfunction and pulmonary hypertension in patients with end-stage liv...... type-5 inhibitor sildenafil, the present study could not demonstrate any clinical relevant influence on splanichnic blood flow, oxygen consumption or the HVPG....

  14. Intraoperative changes of transcranial Doppler velocity: relation to arterial oxygen content and whole-blood viscosity

    NARCIS (Netherlands)

    Schuurman, P. R.; Albrecht, K. W.

    1999-01-01

    The association of arterial oxygen content (CaO2) and viscosity with transcranial Doppler (TCD) blood flow velocity in the middle cerebral artery was studied in 20 adults without cerebrovascular disease undergoing abdominal surgery associated with significant fluctuations in hematology. TCD

  15. Venous-to-arterial carbon dioxide difference in the resuscitation of patients with severe sepsis and septic shock: A systematic review.

    Science.gov (United States)

    Diaztagle Fernández, J J; Rodríguez Murcia, J C; Sprockel Díaz, J J

    2017-10-01

    The way to assess tissue perfusion during the resuscitation of patients with severe sepsis and septic shock is a current subject of research and debate. Venous oxygen saturation and lactate concentration have been the most frequently used criteria, though they involve known limitations. The venous-to-arterial difference of carbon dioxide (pCO 2 delta) is a parameter than can be used to indicate tissue perfusion, and its determination therefore may be useful in these patients. A qualitative systematic review of the literature was made, comprising studies that assessed pCO 2 delta in adult patients with severe sepsis or septic shock, and published between January 1966 and November 2016 in the Medline-PubMed, Embase-Elsevier, Cochrane Library, and LILACS databases. There was no language restriction. The PRISMA statement was followed, and methodological quality was evaluated. Twelve articles were included, all of an observational nature, and including 10 prospective studies (9 published since 2010). Five documented greater mortality among patients with high pCO 2 delta values, in 3 cases even when achieving venous oxygen saturation targets. In 4 studies, a high pCO 2 delta was related to lower venous oxygen saturation and higher lactate levels, and another 3 documented lesser percentage lactate reductions. The parameter pCO 2 delta has been more frequently assessed in the management of patients with severe sepsis during the last few years. The studies demonstrate its correlation to mortality and other clinical outcomes, defining pCO 2 delta as a useful tool in the management of these patients. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  16. Prophylaxis of Venous Thrombosis.

    Science.gov (United States)

    Goldhaber, Samuel Z.

    2001-06-01

    Mechanical measures such as graduated compression stockings and intermittent compression boots are available for venous thrombosis prophylaxis, but compliance may be limited. Plantar venous pneumatic compression devices have attained widespread acceptance by both patients and nurses because of their comfort and compact size, but their track record for efficacy is poor. Inferior vena cava filters prevent pulmonary embolism, but do not halt the thrombotic process or prevent venous thrombosis. Pharmacologic prophylaxis traditionally has relied upon minidose unfractionated heparin; however, re-examination is warranted in the face of increasingly ill and complex patients. My opinion is that small, fixed doses of once-daily low molecular weight heparin will eventually replace minidose unfractionated heparin as the standard pharmacologic prophylaxis regimen for most surgical and medical patients. Prolongation of prophylaxis after hospital discharge should receive increased emphasis. Most patients being transferred to a skilled nursing facility should receive venous thromboembolism prophylaxis. Similarly, most patients undergoing total hip or knee replacement should receive prolonged preventive regimens, with at least 1 month of anticoagulation. Despite advances, certain aspects of venous thrombosis prophylaxis remain problematic. First, a surprisingly high number of hospitalized patients develop venous thrombosis because of failed (rather than omitted) prophylaxis. Second, many patients in intensive care have a combination of peripheral vascular disease and active bleeding (usually gastrointestinal) that precludes mechanical or pharmacologic prophylaxis. Third, neurosurgical patients undergoing craniotomy for brain tumors suffer a high rate of venous thrombosis and major pulmonary embolism despite the routine use of combined mechanical and pharmacologic prophylaxis. My opinion is that these three areas, in addition to the hospital culture of prophylaxis, should receive

  17. Long term follow-up of 43 pure dural arteriovenous fistulae (AVF) of the lateral sinus

    Energy Technology Data Exchange (ETDEWEB)

    Fermand, M; Reizine, D; Melki, J P; Riche, M C; Merland, J J

    1987-07-01

    Fourty-three patients with arterio-venous fistulae of the dura of the transverse sinus with a complaint of tinnitus are reviewed, with a follow-up of 12 months to 11 years. 34 patients were embolized, 2 treated surgically, and 7 were untreated. Embolization appears to have been beneficial. The benign nature of this abnormality must be emphasized, and serious psychological study of the patient must be made before deciding on therapy.

  18. Effect of oxygen content on n-heptane auto-ignition characteristics in a HCCI engine

    International Nuclear Information System (INIS)

    Wu, Zhijun; Kang, Zhe; Deng, Jun; Hu, Zongjie; Li, Liguang

    2016-01-01

    Highlights: • n-Heptane HCCI combustion under air and oxygen intake was compared. • n-Heptane auto-ignition postponed due to higher specific heat capacity as oxygen increase. • The increment of heat release fraction during low temperature reaction is studied. • Oxygen enrichment lead to suppressed negative temperature coefficient. • The mechanism of low temperature reaction enhancement as oxygen increase is investigated. - Abstract: To take maximum advantage of the high efficiency of homogeneous charge compression ignition combustion mode and internal combustion Rankine cycle concept, in this study, the n-heptane auto-ignition characteristics have been investigated using a compression ignition internal combustion Rankine cycle engine test bench and a zero-dimensional thermodynamic model coupled with a detailed kinetic model. The n-heptane auto-ignition process shows that under both air and oxygen intake, a typical two-stage combustion in which oxygen enrichment has very minor effects on the n-heptane high temperature reaction. The higher specific heat capacity of oxygen compared with nitrogen leads to an overall increased specific heat capacity, which lowers the in-cylinder temperature during compression stroke, thereby delaying the low temperature reaction initial timing. The higher oxygen content also improves the H-atom abstraction, first O_2 addition, second O_2 addition and peroxyalkylhydroperoxide isomerization, thereby improving the overall reaction rate and the heat release fraction of low temperature reaction. As a result, the in-cylinder temperature at the end of low temperature reaction also increases, thereby shortening significantly the negative temperature coefficient duration compared with a combustion cycle using air as oxidizer.

  19. Zero added oxygen for high quality sputtered ITO: A data science investigation of reduced Sn-content and added Zr

    International Nuclear Information System (INIS)

    Peshek, Timothy J.; Burst, James M.; Coutts, Timothy J.; Gessert, Timothy A.

    2016-01-01

    The authors demonstrate mobilities of >45 cm 2 /V s for sputtered tin-doped indium oxide (ITO) films at zero added oxygen. All films were deposited with 5 wt. % SnO 2 , instead of the more conventional 8–10 wt. %, and had varying ZrO 2 content from 0 to 3 wt. %, with a subsequent reduction in In 2 O 3 content. These films were deposited by radio-frequency magnetron sputtering from nominally stoichiometric targets with varying oxygen partial pressure in the sputter ambient. Anomalous behavior was discovered for films with no Zr-added, where a bimodality of high and low mobilities was discovered for nominally similar growth conditions. However, all films showed the lowest resistivity and highest mobilities when the oxygen partial pressure in the sputter ambient was zero. This result is contrasted with several other reports of ITO transport performance having a maximum for small but nonzero oxygen partial pressure. This result is attributed to the reduced concentration of SnO 2 . The addition of ZrO 2 yielded the highest mobilities at >55 cm 2 /V s and the films showed a modest increase in optical transmission with increasing Zr-content

  20. Sildenafil does not influence hepatic venous pressure gradient in patients with cirrhosis

    DEFF Research Database (Denmark)

    Clemmesen, J.O.; Giraldi, A.; Ott, P.

    2008-01-01

    AIM: To investigate if sildenafil increases splanchnic blood flow and changes the hepatic venous pressure gradient (HVPG) in patients with cirrhosis. Phosphodiesterase type-5 inhibitors are valuable in the treatment of erectile dysfunction and pulmonary hypertension in patients with end-stage liv...... type-5 inhibitor sildenafil, the present study could not demonstrate any clinical relevant influence on splanichnic blood flow, oxygen consumption or the HVPG Udgivelsesdato: 2008/10/28...

  1. 'Multi-associations': predisposed to misinterpretation of peripheral tissue oxygenation and circulation in neonates.

    Science.gov (United States)

    Pichler, Gerhard; Pocivalnik, Mirjam; Riedl, Regina; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt

    2011-08-01

    Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO(2)), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO(2)), oxygen consumption (VO(2)), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO(2)), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO(2)) were calculated. All demographic parameters except for Hbflow and DO(2) correlated with NIRS parameters. Heart rate correlated with TOI, SvO(2), VO(2) and VR. SaO(2) correlated with FOE/FTOE. MAP correlated with Hbflow, DO(2), VO(2) and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO(2). Hb-blood correlated with FOE and VR. pCO(2) levels correlated with TOI and SvO(2). The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data.

  2. Total Hydrocarbon Content (THC) Testing in Liquid Oxygen (LOX)

    Science.gov (United States)

    Meneghelli, B. J.; Obregon, R. E.; Ross, H. R.; Hebert, B. J.; Sass, J. P.; Dirschka, G. E.

    2016-01-01

    The measured Total Hydrocarbon Content (THC) levels in liquid oxygen (LOX) systems at Stennis Space Center (SSC) have shown wide variations. Examples of these variations include the following: 1) differences between vendor-supplied THC values and those obtained using standard SSC analysis procedures; and 2) increasing THC values over time at an active SSC test stand in both storage and run vessels. A detailed analysis of LOX sampling techniques, analytical instrumentation, and sampling procedures will be presented. Additional data obtained on LOX system operations and LOX delivery trailer THC values during the past 12-24 months will also be discussed. Field test results showing THC levels and the distribution of the THC's in the test stand run tank, modified for THC analysis via dip tubes, will be presented.

  3. Complications of central venous stenosis due to permanent central venous catheters in children on hemodialysis.

    Science.gov (United States)

    Rinat, Choni; Ben-Shalom, Efrat; Becker-Cohen, Rachel; Feinstein, Sofia; Frishberg, Yaacov

    2014-11-01

    Central venous catheters are frequently used as access for hemodialysis (HD) in children. One of the known complications is central venous stenosis. Although this complication is not rare, it is often asymptomatic and therefore unacknowledged. Superior vena cava (SVC) stenosis is obviously suspected in the presence of upper body edema, but several other signs and symptoms are often unrecognized as being part of this syndrome. We describe four patients with various manifestations of central venous stenosis and SVC syndrome. These sometimes life- or organ-threatening conditions include obstructive sleep apnea, unresolving stridor, increased intracranial pressure, increased intraocular pressure, right-sided pleural effusion, protein-losing enteropathy and lymphadenopathy. The temporal relationship of these complications associated with the use of central venous catheters and documentation of venous stenosis, together with their resolution after alleviation of high venous pressure, points to a causal role. We suggest pathophysiological mechanisms for the formation of each of these complications. In patients with occlusion of the SVC, various unexpected clinical entities can be caused by high central venous pressure. As often the etiology is not obvious, a high index of suspicion is needed as in some cases prompt alleviation of the high pressure is mandatory.

  4. Electrical features of an amorphous indium-gallium-zinc-oxide film transistor using a double active matrix with different oxygen contents

    International Nuclear Information System (INIS)

    Koo, Ja Hyun; Kang, Tae Sung; Hong, Jin Pyo

    2012-01-01

    The electrical characteristics of amorphous indium-gallium-zinc-oxide (a-IGZO) thin film transistor (TFTs) are systematically studied using a double a-IGZO active layer that is composed of a-IGZO x (oxygen-ion-poor region) and a-IGZO y (oxygen-ion-rich-region). An active layer is designed to have a serially-stacked bi-layer matrix with different oxygen contents, providing the formation of different electron conduction channels. Two different oxygen contents in the active layer are obtained by varying the O 2 partial pressure during sputtering. The a-IGZO TFT based on a double active layer exhibits a high mobility of 9.1 cm 2 /Vsec, a threshold voltage (V T ) of 16.5 V, and ΔV T shifts of less than 1.5 V under gate voltage stress. A possible electrical sketch for the double active layer channel is also discussed.

  5. Compression therapy in mixed ulcers increases venous output and arterial perfusion.

    Science.gov (United States)

    Mosti, Giovanni; Iabichella, Maria Letizia; Partsch, Hugo

    2012-01-01

    This study was conducted to define bandage pressures that are safe and effective in treating leg ulcers of mixed arterial-venous etiology. In 25 patients with mixed-etiology leg ulcers who received inelastic bandages applied with pressures from 20 to 30, 31 to 40, and 41 to 50 mm Hg, the following measurements were performed before and after bandage application to ensure patient safety throughout the investigation: laser Doppler fluxmetry (LDF) close to the ulcer under the bandage and at the great toe, transcutaneous oxygen pressure (TcPo(2)) on the dorsum of the foot, and toe pressure. Ejection fraction (EF) of the venous pump was performed to assess efficacy on venous hemodynamics. LDF values under the bandages increased by 33% (95% confidence interval [CI], 17-48; P pressure ranges applied. At toe level, a significant decrease in flux of -20% (95% CI, -48 to 9; P bandage pressure >41 mm Hg. Toe pressure values and TcPo(2) showed a moderate increase, excluding a restriction to arterial perfusion induced by the bandages. Inelastic bandages were highly efficient in improving venous pumping function, increasing the reduced ejection fraction by 72% (95% CI, 50%-95%; P pressure of 21 to 30 mm Hg and by 103% (95% CI, 70%-128%; P ulceration, an ankle-brachial pressure index >0.5 and an absolute ankle pressure of >60 mm Hg, inelastic compression of up to 40 mm Hg does not impede arterial perfusion but may lead to a normalization of the highly reduced venous pumping function. Such bandages are therefore recommended in combination with walking exercises as the basic conservative management for patients with mixed leg ulcers. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  6. Determination of oxygen content and carbonate impurity in YBa2Cu3O7-x by diffuse reflectance infrared spectroscopy

    International Nuclear Information System (INIS)

    Merzbacher, C.I.; Bonner, B.P.

    1991-01-01

    Samples of YBa 2 Cu 3 O 7-x with x ranging from ∼0 to 0.65 have been analyzed by diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) in the midinfrared region (400--6000 cm -1 ). Spectral line shapes vary gradually as a function of oxygen stoichiometry, and the reflectance at 400 and 1000 cm -1 decreases linearly with decreasing oxygen content. Spectra of samples that were incompletely synthesized or exposed to a 4% CO 2 atmosphere at 650 degree C clearly indicated the presence of carbonate. DRIFTS is therefore a quick, nondestructive method for determining oxygen content in YBa 2 Cu 3 O 7-x powders, and for detecting carbonate species due to synthesis error or reaction with CO 2 -bearing atmosphere

  7. Study of dissolved oxygen content in the Eastern Bosporus Strait (Peter the Great Bay, Sea of Japan)

    Science.gov (United States)

    Grigoryeva, N. I.

    2017-09-01

    Seasonal changes in the dissolved oxygen (DO) content in water were analyzed based on long-term observations (2006-2013) in the Eastern Bosporus Strait (Peter the Great Bay, Sea of Japan). It was found that the monthly average DO concentrations at the bottom of the strait were significantly lower in summer than the average annual long-term data. The minimum DO contents were recorded during four months, from July to October. It was shown that the DO content in water depended on changes in current directions in the strait: lower DO contents resulted from hypoxic water inflow, mostly from Amur Bay.

  8. Body fat does not affect venous bubble formation after air dives of moderate severity: theory and experiment

    NARCIS (Netherlands)

    Schellart, Nico A. M.; van Rees Vellinga, Tjeerd P.; van Hulst, Rob A.

    2013-01-01

    For over a century, studies on body fat (BF) in decompression sickness and venous gas embolism of divers have been inconsistent. A major problem is that age, BF, and maximal oxygen consumption (Vo2max) show high multicollinearity. Using the Bühlmann model with eight parallel compartments, preceded

  9. Long term follow-up of 43 pure dural arteriovenous fistulae (AVF) of the lateral sinus

    International Nuclear Information System (INIS)

    Fermand, M.; Reizine, D.; Melki, J.P.; Riche, M.C.; Merland, J.J.

    1987-01-01

    Fourty-three patients with arterio-venous fistulae of the dura of the transverse sinus with a complaint of tinnitus are reviewed, with a follow-up of 12 months to 11 years. 34 patients were embolized, 2 treated surgically, and 7 were untreated. Embolization appears to have been beneficial. The benign nature of this abnormality must be emphasized, and serious psychological study of the patient must be made before deciding on therapy. (orig.)

  10. Determination of active oxygen content in rare earth peroxides

    International Nuclear Information System (INIS)

    Queiroz, Carlos A.S.; Abrao, Alcidio

    1993-01-01

    The content of active oxygen in rare earth peroxides have been determined after the dissolution of the samples with hydrocloridic acid in the presence of potassium iodide. The free generated iodine is titrated with sodium thiosulfate using starch as indicator. The oxidation of iodide to the free iodine indicates the presence of a higher valence state rare earth oxide, until now specifically recognized for the oxides of cerium (Ce O 2 ), praseodymium (Pr 6 O 1 1) and terbium (TB 4 O 7 ). recently the authors synthesized a new series of rare earth compounds, the peroxides. These new compounds were prepared by precipitating the rare earth elements complexed with carbonate ion by addition of hydrogen peroxide. the authors demonstrated that all rare earth elements, once solubilized by complexing with carbonate ion, are quantitatively precipitated as peroxide by addition of hydrogen peroxide. (author)

  11. Protocol for the realization of venous mapping by chronic venous insufficiency in lower limbs under sonographic guide

    International Nuclear Information System (INIS)

    Blanco Rojas, Diego Jose

    2013-01-01

    The current state of knowledge is reviewed with respect to the realization of lower limbs venous mapping. Venous mapping is obtained by the use of color and spectral Doppler ultrasound. Doppler ultrasound has provided a precise graphical representation of the superficial and deep venous systems. The performance of the venous mapping is considered essential for the correct handling of venous diseases. The anatomical and pathophysiological basic concepts are defined to realize the sonographic assessment of the veins of the lower limbs. The required technical aspects are revised for the realization of sonographic exploration of the patient with venous insufficiency. Sonographic findings are characterized to support the diagnostic of venous insufficiency of the lower limbs. The CEAP (clinical-etiologic-anatomic-pathophysiologic) classification is utilized to differentiate forms and degrees of severity of the disorder, and has allowed an interinstitutional comparison in clinical studies, the evaluation of treatment and monitoring of patients. A proposal is designed to perform reports that have served of guide surgical to vascular surgeons [es

  12. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R(2) = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway...

  13. Evaluation of the perioperative period of orthotopic liver transplantation with veno-venous bypass and without it

    Directory of Open Access Journals (Sweden)

    D. A. Levit

    2017-01-01

    Full Text Available Orthotopic liver transplantation (OLT is the only treatment for many patients with end-stage chronic liver diseases. In patients with complete vena cava inferior (VCI cross-clamping veno-venous bypass (VVB is either used or not depending on the indications. The case management of the patient with complete VCI cross-clamping depends on the initial state of the recipient and the transplant team’s opinion.Aim. To compare the perioperative period of OLT depending on the method to conduct the main stage of the surgery: with the use of veno-venous bypass and without it with complete VCI cross-clamping.Materials and methods. In Group 1 (n = 20, OLT was performed without VVB with complete VCI cross-clamping; in Group 2 (n = 26, the surgery was conducted with veno-venous bypass. Patients in both groups were similar in age (46.15 ± 10.22 and 47.3 ± 9.29, respectively, in severity of the disease: Child-Pugh (10.15 ± 1.42 and 10.19 ± 2.45, MELD 16.47 ± 4.41 and 15.8 ± 4.95.Results. We determined and evaluated hemodynamic parameters, oxygen transport, the quantitative and qualitative infusion composition, urine output, characteristics of the postoperative period.Conclusion. Our data show that changes in hemodynamic and oxygen transport are associated with reperfusion syndrome and do not depend on the method of transplantation. At the same time, it reduces the blood loss, time of surgery, and the duration of postoperative mechanical ventilation and stay in the ICU after liver transplantation in patients without veno-venous bypass.

  14. Extracorporeal membrane oxygenation after intravenous injection of paraffin oil

    DEFF Research Database (Denmark)

    Pasgaard, Thomas; Huynh, Anh-Nhi Thi; Gjedsted, Jakob

    2016-01-01

    We present a rare cause of acute respiratory distress syndrome (ARDS) due to an accidental intravascular injection of paraffin oil. While there is no specific therapy, we decided to support the patient with veno-venous extracorporeal membrane oxygenation (V-V ECMO) to allow the ARDS to resolve. A...

  15. Colorectal cancer with venous tumor thrombosis

    OpenAIRE

    Kensuke Otani; Soichiro Ishihara; Keisuke Hata; Koji Murono; Kazuhito Sasaki; Koji Yasuda; Takeshi Nishikawa; Toshiaki Tanaka; Tomomichi Kiyomatsu; Kazushige Kawai; Hiroaki Nozawa; Hironori Yamaguchi; Toshiaki Watanabe

    2018-01-01

    Summary: Colorectal cancer is seldom accompanied by venous tumor thrombosis, and little is known about the features of venous tumor thrombosis in colorectal cancer. However, some reports show that colorectal cancer patients can develop venous tumor thrombosis and warn clinicians not to overlook this complication. In this report, we perform a review of 43 previously reported cases and investigate the characteristics of colorectal cancer accompanied by venous tumor thrombosis. The histological ...

  16. Diagnosis and endovascular treatment of multiple cerebral venous and venous sinuses thrombosis

    International Nuclear Information System (INIS)

    Li Baomin; Zhang Ji; Yin Ling; Huang Xusheng; Jiang Jinli; Liu Jun; Lang Senyang; Zhou Dingbiao; Zhu Ke

    2000-01-01

    Objective: Eighty-five cases with multiple cerebral venous and venous sinuses thrombosis including the diagnosis and endovascular therapy were reported. Methods: The long T2 and short T1 signals in the related regions of multiple venous sinuses on MRI and prolonged blood circulation time of the brain with tortuous dilatation of vein in angiography were the important characteristics for the diagnosis. Of the 85 cases, the treatment procedures were consisted of injecting urokinase intermittently via common carotid artery and intra-sinus contact thrombolysis as well as warfarin intake orally. Results: Intracranial pressure of 80 cases reduced down between 230 and 300 mm H 2 O, and clinical deficits were markedly improved within 10 days. Re-angiography of 18 cases revealed recanalization partly in 5 cases and circulation time appeared near normal i 8 cases during one week after therapy. Conclusions: Combined intraarterial thrombolysis consecutively with general anticoagulation for the treatment of multiple thrombosis in cerebral venous sinuses may be one of the effective means

  17. Significance of venous anastomosis in fingertip replantation.

    Science.gov (United States)

    Hattori, Yasunori; Doi, Kazuteru; Ikeda, Keisuke; Abe, Yukio; Dhawan, Vikas

    2003-03-01

    Adequate venous outflow is the most important factor for successful fingertip replantation. The authors have attempted venous anastomosis in all cases of fingertip replantation to overcome postoperative congestion. In this article, the significance of venous repair for fingertip replantation is described from the authors' results of 64 complete fingertip amputations in 55 consecutive patients, which were replanted from January of 1996 to June of 2001. The overall survival rate was 86 percent. Of the 44 replantations in zone I, 37 survived, and the success rate was 84 percent. Of the 20 replantations in zone II, 18 survived, and the success rate was 90 percent. Venous anastomosis was attempted in all cases, but it was possible in 39 zone I and in all zone II replantations. For arterial repair, vein grafts were necessary in 17 of the 44 zone I and in one of the 20 zone II replantations; for venous repair, they were necessary in six zone I replantations and one zone II replantation. Postoperative vascular complications occurred in 15 replantations. There were five cases of arterial thrombosis and 10 cases of venous congestion. Venous congestion occurred in nine zone I and one zone II replantations. In five of these 10 replantations, venous anastomosis was not possible. In another five replantations, venous outflow was established at the time of surgery, but occlusion occurred subsequently. Except for the five failures resulting from arterial thrombosis, successful venous repair was possible in 49 of 59 replantations (83 percent). Despite the demand for skillful microsurgical technique and longer operation time, the authors' results using venous anastomosis in successful fingertip replantations are encouraging. By performing venous anastomosis, external bleeding can be avoided and a higher survival rate can be achieved. Venous anastomosis for fingertip replantation is a reliable and worthwhile procedure.

  18. TECHNIQUES OF EVALUATION OF HEMOGLOBIN OXYGEN SATURATION IN CLINICAL OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2016-01-01

    Full Text Available Oxygen content in body fluids and tissues is an important indicator of life support functions. A number of ocular pathologies, e.g. glaucoma, are of presumable vascular origin which means altered blood supply and oxygen circulation. Most oxygen is transported in the blood in the association with hemoglobin. When passing through the capillaries, hemoglobin releases oxygen, converting from oxygenated form to deoxygenated form. This process is accompanied by the changes in spectral characteristics of hemoglobin which result in different colors of arterial and venous blood. Photometric technique for the measurement of oxygen saturation in blood is based on the differences in light absorption by different forms of hemoglobin. The measurement of saturation is called oximetry. Pulse oximetry with assessment of tissue oxygenation is the most commonly used method in medicine. The degree of hemoglobin oxygen saturation in the eye blood vessels is the most accessible for noninvasive studies during ophthalmoscopy and informative. Numerous studies showed the importance of this parameter for the diagnosis of retinopathy of various genesis, metabolic status analysis in hyperglycemia, diagnosis and control of treatment of glaucoma and other diseases involving alterations in eye blood supply. The specific method for evaluation of oxygen concentration is the measurement of pressure of oxygen dissolved in the blood, i.e. partial pressure of oxygen. In ophthalmological practice, this parameter is measured in anterior chamber fluid evaluating oxygen level for several ophthalmopathies including different forms of glaucoma, for instillations of hypotensive eye drops as well as in vitreous body near to the optic disc under various levels of intraocular pressure. Currently, monitoring of oxygen saturation in retinal blood vessels, i.e. retinal oximetry, is well developed. This technique is based on the assessment of light absorption by blood depending on

  19. 'Multi-associations': predisposed to misinterpretation of peripheral tissue oxygenation and circulation in neonates

    International Nuclear Information System (INIS)

    Pichler, Gerhard; Pocivalnik, Mirjam; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt; Riedl, Regina

    2011-01-01

    Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO 2 ), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO 2 ), oxygen consumption (VO 2 ), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO 2 ), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO 2 ) were calculated. All demographic parameters except for Hbflow and DO 2 correlated with NIRS parameters. Heart rate correlated with TOI, SvO 2 , VO 2 and VR. SaO 2 correlated with FOE/FTOE. MAP correlated with Hbflow, DO 2 , VO 2 and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO 2 . Hb-blood correlated with FOE and VR. pCO 2 levels correlated with TOI and SvO 2 . The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data

  20. Venous abnormalities demonstrated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Tsukune, Y; Ashida, H; Tokuda, M; Oyama, Y [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-05-01

    CT is capable of demonstrating various venous changes. However, little have been described on this subject in the literature. Examples of various venous abnormalities such as obstructed jugular vein, superior and inferior vena cava (IVC), tumor invasion of IVC and renal vein and venous changes in portal hypertension were presented. It was stressed that noninvasive CT is a good tool in diagnosis of some of venous changes and may be able to eliminate angiography in such cases.

  1. Malformación arterio-venosa cerebral causante de insuficiencia cardiaca congestiva en un neonato Cerebral arteriovenous malformation as a cause of congestive heart failure in a newborn

    OpenAIRE

    R. Fernández Montes; S. Bueno Pardo; M. Montes Granda; S. Lareu Vidal; M. González Sánchez; G. Solís Sánchez

    2013-01-01

    La malformación arterio-venosa de la vena de Galeno representa una anomalía congénita vascular muy infrecuente. Esta patología se presenta de forma preferente en el periodo neonatal pudiendo causar una importante morbi-mortalidad. La forma de presentación clínica es muy variable, siendo la asociación de soplo craneal e insuficiencia cardiaca la forma de presentación más frecuente en el periodo neonatal. El grado de insuficiencia cardiaca asociada constituye el principal factor pronóstico y co...

  2. 99 Tc NMR determination of the oxygen isotope content in 18 O-enriched water.

    Science.gov (United States)

    Tarasov, Valerii P; Kirakosyan, Gayana А; German, Konstantin E

    2018-03-01

    99 Tc NMR has been suggested as an original method of evaluating the content of oxygen isotopes in oxygen-18-enriched water, a precursor for the production of radioisotope fluorine-18 used in positron emission tomography. To this end, solutions of NH 4 TcO 4 or NaTcO 4 (up to 0.28 mol/L) with natural abundance of oxygen isotopes in virgin or recycled 18 O-enriched water have been studied by 99 Tc NMR. The method is based on 16 O/ 17 O/ 18 O intrinsic isotope effects in the 99 Tc NMR chemical shifts, and the statistical distribution of oxygen isotopes in the coordination sphere of TcO 4 - and makes it possible to quantify the composition of enriched water by measuring the relative intensities of the 99 Tc NMR signals of the Tc 16 O 4-n 18 O n - isotopologues. Because the oxygen exchange between TcO 4 - and enriched water in neutral and alkaline solutions is characterized by slow kinetics, gaseous HCl was bubbled through a solution for a few seconds to achieve the equilibrium distribution of oxygen isotopes in the Tc coordination sphere without distortion of the oxygen composition of the water. Pertechnetate ion was selected as a probe due to its high stability in solutions and the significant 99 Tc NMR shift induced by a single 16 O→ 18 O substitution (-0.43 ± 0.01 ppm) in TcO 4 - and spin coupling constant 1 J( 99 Tc- 17 O) (131.46 Hz) favourable for the observation of individual signals of Tc 16 O 4-n 18 O n - isotopologues. Copyright © 2017 John Wiley & Sons, Ltd.

  3. The dark side of the kidney in cardio-renal syndrome: renal venous hypertension and congestive kidney failure.

    Science.gov (United States)

    Di Nicolò, Pierpaolo

    2018-03-01

    Renal involvement in some forms of acute or chronic diseases, such as heart failure or sepsis, presents with a complex pathophysiological basis that is not always clearly distinguishable. In these clinical settings, kidney failure is traditionally and almost exclusively attributed to renal hypoperfusion and it is commonly accepted that causal elements are pre-renal, such as a reduction in the ejection fraction or absolute or relative hypovolemia acting directly on oxygen transport mechanisms and renal autoregulation systems, causing a reduction of glomerular filtration rate. Nevertheless, the concept emerging from accumulating clinical and experimental evidence is that in complex clinical pictures, kidney failure is strongly linked to the hemodynamic alterations occurring in the renal venous micro and macrocirculation. Accordingly, the transmission of the increased venous pressure to the renal venous compartment and the consequent increasing renal afterload has a pivotal role in determining and sustaining the kidney damage. The aim of this review was to clarify the physiopathological aspects of the link between worsening renal function and renal venous hypertension, analyzing the prognostic and therapeutic implications of the so-called congestive kidney failure in cardio-renal syndrome and in other clinical contexts of its possible onset.

  4. Comparison of two analyzers to determine selected venous blood analytes of Quaker parrots (Myiopsitta monachus).

    Science.gov (United States)

    Rettenmund, Christy L; Heatley, J Jill; Russell, Karen E

    2014-06-01

    Point of care devices can assess electrolyte, blood gas, biochemical, and hematologic values in a critical care setting. Although these devices are commonly used in humans and companion mammals, few studies have assessed their use in avian species. This study compares electrolyte, hemoglobin (Hgb), hematocrit (Hct), acid-base, and venous blood gas parameters between the i-STAT and IRMA TruPoint blood gas analysis systems for 35 Quaker parrots. Agreement between the two analyzers and the effect of gender, time lag between sample analysis, and cartridge expiration were evaluated. Male birds had increased Hgb and Hct compared with females, independent of analyzer method. In expired i-STAT cartridges, only glucose significantly increased. Packed cell volume determined by centrifugation was higher than Hct, as calculated by either analyzer. The analyzers had good agreement for total carbon dioxide, bicarbonate, pH, and Hgb, fair agreement for potassium (K), ionized calcium (iCa), venous partial pressure of carbon dioxide, and base excess, and poor agreement for sodium (Na), venous partial pressure of oxygen (PO2), and oxygen saturation (SO2). Values for Na, iCa, PO2, and SO2 were significantly higher on the IRMA than the i-STAT, while K was significantly lower on the IRMA when compared with the i-STAT. The time lag between sample analyses on the i-STAT and IRMA did not be correlate to any analyte changes. Despite these differences, both the i-STAT and the IRMA appear to be acceptable clinical tools in avian critical care, although reference ranges for each analyzer should be created.

  5. Altered Venous Function during Long-Duration Spaceflights

    Directory of Open Access Journals (Sweden)

    Jacques-Olivier Fortrat

    2017-09-01

    Full Text Available Aims: Venous adaptation to microgravity, associated with cardiovascular deconditioning, may contribute to orthostatic intolerance following spaceflight. The aim of this study was to analyze the main parameters of venous hemodynamics with long-duration spaceflight.Methods: Venous plethysmography was performed on 24 cosmonauts before, during, and after spaceflights aboard the International Space Station. Venous plethysmography assessed venous filling and emptying functions as well as microvascular filtration, in response to different levels of venous occlusion pressure. Calf volume was assessed using calf circumference measurements.Results: Calf volume decreased during spaceflight from 2.3 ± 0.3 to 1.7 ± 0.2 L (p < 0.001, and recovered after it (2.3 ± 0.3 L. Venous compliance, determined as the relationship between occlusion pressure and the change in venous volume, increased during spaceflight from 0.090 ± 0.005 to 0.120 ± 0.007 (p < 0.01 and recovered 8 days after landing (0.071 ± 0.005, arbitrary units. The index of venous emptying rate decreased during spaceflight from −0.004 ± 0.022 to −0.212 ± 0.033 (p < 0.001, arbitrary units. The index of vascular microfiltration increased during spaceflight from 6.1 ± 1.8 to 10.6 ± 7.9 (p < 0.05, arbitrary units.Conclusion: This study demonstrated that overall venous function is changed during spaceflight. In future, venous function should be considered when developing countermeasures to prevent cardiovascular deconditioning and orthostatic intolerance with long-duration spaceflight.

  6. Extracorporeal Membrane Oxygenation Cannula Malposition in the Azygos Vein in a Neonate with Right-Sided Congenital Diaphragmatic Hernia

    Directory of Open Access Journals (Sweden)

    Seung Jun Choi

    2016-05-01

    Full Text Available Malposition of the extracorporeal membrane oxygenation (ECMO venous cannula in the azygos vein is not frequently reported. We hereby present such a case, which occurred in a neonate with right-sided congenital diaphragmatic hernia. Despite ECMO application, neither adequate flow nor sufficient oxygenation was achieved. On the cross-table lateral chest radiograph, the cannula tip was identified posterior to the heart silhouette, which implied malposition of the cannula in the azygos vein. After repositioning the cannula, the target flow and oxygenation were successfully achieved. When sufficient venous flow is not achieved, as in our case, clinicians should be alerted so they can identify the cannula tip location on lateral chest radiograph and confirm whether malposition in the azygos vein is the cause of the ineffective ECMO.

  7. Relative effects of chromium and niobium on microstructure and mechanical properties as a function of oxygen content in TiAl alloys

    International Nuclear Information System (INIS)

    Lamirand, M.; Bonnentien, J.-L.; Ferriere, G.; Guerin, S.; Chevalier, J.-P.

    2007-01-01

    The effects of 2 at.% chromium and niobium on microstructure and mechanical properties of Ti-48Al-x(Cr, Nb) have been investigated for alloys with different oxygen content, ranging from ultra-high purity to doped alloys. Chromium and niobium additions have significant effects for the high purity alloys, whereas for alloys containing oxygen, no significant modification is observed due to the strong stabilizing effect of oxygen on the lamellar microstructure

  8. Combined oral contraceptives: venous thrombosis.

    Science.gov (United States)

    de Bastos, Marcos; Stegeman, Bernardine H; Rosendaal, Frits R; Van Hylckama Vlieg, Astrid; Helmerhorst, Frans M; Stijnen, Theo; Dekkers, Olaf M

    2014-03-03

    Combined oral contraceptive (COC) use has been associated with venous thrombosis (VT) (i.e., deep venous thrombosis and pulmonary embolism). The VT risk has been evaluated for many estrogen doses and progestagen types contained in COC but no comprehensive comparison involving commonly used COC is available. To provide a comprehensive overview of the risk of venous thrombosis in women using different combined oral contraceptives. Electronic databases (Pubmed, Embase, Web of Science, Cochrane, CINAHL, Academic Search Premier and ScienceDirect) were searched in 22 April 2013 for eligible studies, without language restrictions. We selected studies including healthy women taking COC with VT as outcome. The primary outcome of interest was a fatal or non-fatal first event of venous thrombosis with the main focus on deep venous thrombosis or pulmonary embolism. Publications with at least 10 events in total were eligible. The network meta-analysis was performed using an extension of frequentist random effects models for mixed multiple treatment comparisons. Unadjusted relative risks with 95% confidence intervals were reported.Two independent reviewers extracted data from selected studies. 3110 publications were retrieved through a search strategy; 25 publications reporting on 26 studies were included. Incidence of venous thrombosis in non-users from two included cohorts was 0.19 and 0.37 per 1 000 person years, in line with previously reported incidences of 0,16 per 1 000 person years. Use of combined oral contraceptives increased the risk of venous thrombosis compared with non-use (relative risk 3.5, 95% confidence interval 2.9 to 4.3). The relative risk of venous thrombosis for combined oral contraceptives with 30-35 μg ethinylestradiol and gestodene, desogestrel, cyproterone acetate, or drospirenone were similar and about 50-80% higher than for combined oral contraceptives with levonorgestrel. A dose related effect of ethinylestradiol was observed for gestodene

  9. Venous chest anatomy: clinical implications

    International Nuclear Information System (INIS)

    Chasen, M.H.; Charnsangavej, C.

    1998-01-01

    This article provides a practical approach to the clinical implications and importance of understanding the collateral venous anatomy of the thorax. Routine radiography, conventional venography, computed tomography (CT), and magnetic resonance (MR) imaging studies provide correlative anatomic models for the demonstration of how interconnecting collateral vascular networks within the thorax maintain venous stability at all times. Five major systems comprise the collateral venous network of the thorax ( Fig. 1 ). These include the paravertebral, azygos-hemiazygos, internal mammary, lateral thoracic, and anterior jugular venous systems (AJVS). The five systems are presented in the following sequence: (a) a brief introduction to the importance of catheter position and malposition in understanding access to the thoracic venous system, (b) the anatomy of the azygos-hemiazygos systems and their relationship with the paravertebral plexus, (c) the importance of the AJVS, (d) 'loop' concepts interconnecting the internal mammary and azygos-hemiazygos systems by means of the lateral thoracic and intercostal veins, and (e) the interconnecting venous networks on the thoracic side of the thoracoabdominal junction. Certain aspects of the venous anatomy of the thorax will not be discussed in this chapter and include (a) the intra-abdominal anastomoses between the superior and inferior vena cavae (IVC) via the internal mammary, lateral thoracic, and azygos-hemiazygos systems (beyond the scope of this article), (b) potential collateral vessels involving vertebral, parascapular, thyroidal, thymic, and other smaller veins that might anastomose with the major systems, and (c) anatomic variants and pitfalls that may mimic pathologic conditions (space limitations). (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  10. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  11. Effects of low-frequency ultrasound on microcirculation in venous leg ulcers

    Directory of Open Access Journals (Sweden)

    Uwe Wollina

    2011-01-01

    Full Text Available Background: Therapeutic low-frequency ultrasound (US has been used for many years to improve wound healing in chronic wounds like venous leg ulcers. No human data are available for the possible effects of single US applications on microcirculation and their frequency-dependency. Aims: To investigated the role of therapeutic low-frequency US on microcirculation of venous leg ulcers in vivo. Patients and Methods: This is a pilot study on an inpatient basis. We use a newly developed low-frequency continuous-wave US-equipment composed of a US transducer based on piezo-fiber composites that allow the change of frequency. In this study, we apply US of 34 kHz, 53.5 kHz, and 75 kHz respectively. Twelve patients with chronic venous leg ulcers are analyzed. As an adjunct to good ulcer care, therapeutic US is applied, non-contacting, once a day, in a subaqual position for 10 minutes. Microcirculation is assessed in the ulcers adjacent to skin before US-therapy, immediately after the treatment and 30 minutes later. We use a micro-light guide spectrophotometer (O2C, LEA Medizintechnik GmbH, Gieίen, Germany for calculation of blood flow velocity, hemoglobin oxygen saturation (SCO 2 and relative hemoglobin concentration (rHb in 2 and 8 mm depth. Contact-free remission spectroscopy (SkinREM3, Color Control Chemnitz GmbH, Chemnitz, Germany allows contact free measurements in the VIS-NIR range of the spectrum (400 ± 1600 nm. Results: It is seen that therapeutic US is well tolerated. One patient dropped out from a treatment series since he developed erysipelas responding to standard antibiotic. Effects were seen at 34 kHz only. The SO 2 values increased after single US application. The values for rHb were higher in the superficial layer of the wound bed (depth 2 mm compared to deeper parts (8 mm depth. US treatment did not result in significant changes of rHb and blood cell velocity. The data obtained by remission spectroscopy disclose an increase of oxygenized

  12. Venous pump of the calf: a study of venous and muscular pressures.

    Science.gov (United States)

    Alimi, Y S; Barthelemy, P; Juhan, C

    1994-11-01

    Little data are available concerning the relation between the muscular pumping mechanism and the variation of superficial and deep venous pressure during normal action of the calf pump; therefore we undertook this study to determine the pressure values in three compartments of the calf and in the deep and the superficial venous system and to establish correlation between muscular and venous pressure. Nine healthy young women with a mean age of 23 years (range 19 to 28 years) were examined. In the same calf, a muscular catheter was placed in the deep posterior compartment (DPC), in the superficial posterior compartment (SPC), and in the anterior tibial compartment (ATC), and a vascular catheter was placed in the popliteal vein and in the greater saphenous vein (GSV). The five lines of pressure were simultaneously recorded in the following situations: at rest, during Valsalva maneuver, foot flexion, and foot extension. The situation was studied with the patient in the following positions: decubitus, sitting, standing, and squatting. A final continuous recording was carried out after the patient had been walking for 5 minutes. Mean values with standard errors of muscular and venous pressure were established in each situation. At rest and during Valsalva maneuver, the muscular pressures did not vary, whereas venous pressures increased significantly when the patient was sitting and standing. On the other hand, squatting was associated with a rise in the muscular and vein pressures. Foot flexion entailed a significant increase in the ATC pressure and a rise in the GSV pressure, whereas foot extension caused the DPC pressure to rise without venous pressure modifications. Walking was associated with an alternating increase in the DPC, SPC, GSV and popliteal vein pressures when the foot was compressed to floor followed by a significant decrease when the foot pressure was released. The variations in the deep and superficial venous pressures when the patient is sitting and

  13. Total hydrocarbon content (THC) testing in liquid oxygen (LOX) systems

    Science.gov (United States)

    Meneghelli, B. J.; Obregon, R. E.; Ross, H. R.; Hebert, B. J.; Sass, J. P.; Dirschka, G. E.

    2015-12-01

    The measured Total Hydrocarbon Content (THC) levels in liquid oxygen (LOX) systems at Stennis Space Center (SSC) have shown wide variations. Examples of these variations include the following: 1) differences between vendor-supplied THC values and those obtained using standard SSC analysis procedures; and 2) increasing THC values over time at an active SSC test stand in both storage and run vessels. A detailed analysis of LOX sampling techniques, analytical instrumentation, and sampling procedures will be presented. Additional data obtained on LOX system operations and LOX delivery trailer THC values during the past 12-24 months will also be discussed. Field test results showing THC levels and the distribution of the THC's in the test stand run tank, modified for THC analysis via dip tubes, will be presented.

  14. A novel, non-invasive diagnostic clinical procedure for the determination of an oxygenation status of chronic lower leg ulcers using peri-ulceral transcutaneous oxygen partial pressure measurements: results of its application in chronic venous insufficiency (CVI).

    Science.gov (United States)

    Barnikol, Wolfgang K R; Pötzschke, Harald

    2012-01-01

    The basis for the new procedure is the simultaneous transcutaneous measurement of the peri-ulceral oxygen partial pressure (tcPO(2)), using a minimum of 4 electrodes which are placed as close to the wound margin as possible, additionally, as a challenge the patient inhales pure oxygen for approximately 15 minutes. In order to evaluate the measurement data and to characterise the wounds, two new oxygen parameters were defined: (1) the oxygen characteristic (K-PO(2)), and (2) the oxygen inhomogeneity (I-PO(2)) of a chronic wound. The first of these is the arithmetic mean of the two lowest tcPO(2) measurement values, and the second is the variation coefficient of the four measurement values. Using the K-PO(2) parameter, a grading of wound hypoxia can be obtained. To begin with, the physiologically regulated (and still compensated) hypoxia with K-PO(2) values of between 35 and 40 mmHg is distinguished from the pathological decompensated hypoxia with K-PO(2) values of between 0 and 35 mmHg; the first of these still stimulates self-healing (within the limits of the oxygen balance). The decompensated hypoxia can be (arbitrarily) divided into "simple" hypoxia (Grade I), intense hypoxia (Grade II) and extreme hypoxia (Grade III), with the possibility of intermediate grades (I/II and II/III).Measurements were carried out using the new procedure on the skin of the right inner ankle of 21 healthy volunteers of various ages, and in 17 CVI (chronic venous insufficiency) wounds. Sixteen of the 17 CVI wounds (i.e., 94%) were found to be pathologically hypoxic, a state which was not found in any of the healthy volunteers. The oxygen inhomogeneity (I-PO(2)) of the individual chronic wounds increased exponentially as a function of the hypoxia grading (K-PO(2)), with a 10-fold increase with extreme hypoxia in contrast to a constant value of approximately 14% in the healthy volunteers. This pronounced oxygen inhomogeneity explains inhomogeneous wound healing, resulting in the so

  15. Evaluation of hepatic venous pulsatility and portal venous velocity with doppler ultrasonography during the puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Pekindil, Goekhan [Department of Radiology, Trakya University School of Medicine, 22030 Edirne (Turkey); Varol, Fuesun G. [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey); Ali Yuece, M. [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey); Yardim, Turgut [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey)

    1999-03-01

    Objective: The aim of this study is to evaluate pregnancy-induced changes of hepatic venous pulsatility and portal venous velocity in the puerperium and to determine if these changes disappeared by the end of the puerperium. Methods and material: Healthy normal volunteers (90) were examined on the 2nd and 7th days of puerperium and between the 6th and 8th weeks postpartum. Doppler waveform patterns were obtained in the middle hepatic vein and main portal vein. The hepatic venous pulsatility was named as normal, damped or flat. Results: On the 2nd day postpartum, the hepatic vein pulsatility was shown as normal in 8 (26%), damped in 11 (37%) and flat in 11 (37%) cases. On the 7th day postpartum, 15 (50%) cases had normal, 9 (30%) cases had dampened, and 6 (20%) cases had still flat pattern. The majority of the cases (60%) displayed normal hepatic venous pulsatility in the 6th and 8th weeks of puerperium, whereas 23% had still dampened and 17% had flat patterns. There was a trend toward normal pulsatility with increasing puerperal age. The mean portal venous velocity was still higher than the non-pregnant levels and did not showed significant alterations during puerperium. Conclusion: This study emphasised that, since pregnancy-induced alterations in hepatic venous pulsatility and portal venous velocity had not completely returned to normal in most cases until the end of the puerperium, these physiological changes should be considered whenever hepatic and portal systems are interpreted with Doppler sonography during the puerperal period.

  16. Evaluation of hepatic venous pulsatility and portal venous velocity with doppler ultrasonography during the puerperium

    International Nuclear Information System (INIS)

    Pekindil, Goekhan; Varol, Fuesun G.; Ali Yuece, M.; Yardim, Turgut

    1999-01-01

    Objective: The aim of this study is to evaluate pregnancy-induced changes of hepatic venous pulsatility and portal venous velocity in the puerperium and to determine if these changes disappeared by the end of the puerperium. Methods and material: Healthy normal volunteers (90) were examined on the 2nd and 7th days of puerperium and between the 6th and 8th weeks postpartum. Doppler waveform patterns were obtained in the middle hepatic vein and main portal vein. The hepatic venous pulsatility was named as normal, damped or flat. Results: On the 2nd day postpartum, the hepatic vein pulsatility was shown as normal in 8 (26%), damped in 11 (37%) and flat in 11 (37%) cases. On the 7th day postpartum, 15 (50%) cases had normal, 9 (30%) cases had dampened, and 6 (20%) cases had still flat pattern. The majority of the cases (60%) displayed normal hepatic venous pulsatility in the 6th and 8th weeks of puerperium, whereas 23% had still dampened and 17% had flat patterns. There was a trend toward normal pulsatility with increasing puerperal age. The mean portal venous velocity was still higher than the non-pregnant levels and did not showed significant alterations during puerperium. Conclusion: This study emphasised that, since pregnancy-induced alterations in hepatic venous pulsatility and portal venous velocity had not completely returned to normal in most cases until the end of the puerperium, these physiological changes should be considered whenever hepatic and portal systems are interpreted with Doppler sonography during the puerperal period

  17. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben

    2010-01-01

    using a biosensitive electrode (Exp. 1) or a standard colourimetric method (Exp. 2). In general, glucose measured in whole blood was 7-11% lower than in plasma at low glucose levels (3.5-5 mM), whereas the methods agreed well at high glucose levels (10-14 mM). Evaluation of the regression lines between......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...... three different diets with similar contents of starch (470-506 g/kg DM). The diets in both studies differed regarding amount and solubility of fibre. Blood samples were collected repeatedly 0-10 h after morning feeding. Glucose was measured in whole blood using a glucometer (Accu-Chek®) and in plasma...

  18. Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion

    NARCIS (Netherlands)

    van Gemert, Martin J. C.; van den Wijngaard, Jeroen P. H. M.; Lopriore, Enrico; Pasman, Suzanne A.; Vandenbussche, Frank P. H. A.

    2008-01-01

    Twin-twin transfusion syndrome (TTTS) is a severe complication of monozygotic (identical) twin fetuses sharing one single (monochorionic) placenta. TTTS is caused by a net inter-twin transfusion of blood through placental anastomoses, from one twin (the donor) to the other (the recipient), which

  19. A Case of Congenital Uterine Arterio-Venous Malformation Managed by Hysterectomy

    International Nuclear Information System (INIS)

    Bhoil, Rohit; Raghuvanshi, Vandana; Basavaiah, Suhas

    2015-01-01

    A uterine arteriovenous malformation (AVM) is a rare cause of uterine bleeding. It may have varied presentations ranging from being completely asymptomatic; to features of congestive heart failure to vaginal bleeding which may at times life be threatening. Clinical findings in such cases are often un-reliable; requiring a high index of suspicion to make the diagnosis. Sonographic gray scale features are non-specific requiring confirmation with colour and spectral Doppler. We report a case of a 46-year-old lady who presented with heavy vaginal bleeding and ultrasound/colour Doppler evidence of uterine AVM managed by abdominal hysterectomy, describing the imaging features on ultrasound and Doppler. We also discuss in brief about this uncommon but serious condition which the radiologist/gynaecologist may encounter in thier practise. Uterine AV Malformation is a rare but potentially life-threatening cause of menorrhagia which must be kept in the differential diagnosis of sudden and massive vaginal bleeding. Ultrasound remains the modality of choice in diagnosing the condition which requires a high index of clinical suspicion. Color and spectral Doppler ultrasound should be used to supplement the findings and to confirm the diagnosis

  20. Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van; Wijngaard, Jeroen P H M van den [Laser Centre and Department of Obstetrics, Laser Center, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Lopriore, Enrico [Division of Neonatology, Department of Pediatrics, Leiden University Medical Centre, Leiden (Netherlands); Pasman, Suzanne A; Vandenbussche, Frank P H A [Division of Fetal Medicine, Department of Obstetrics, Leiden University Medical Centre, Leiden (Netherlands)], E-mail: m.j.vangemert@amc.uva.nl

    2008-04-07

    Twin-twin transfusion syndrome (TTTS) is a severe complication of monozygotic (identical) twin fetuses sharing one single (monochorionic) placenta. TTTS is caused by a net inter-twin transfusion of blood through placental anastomoses, from one twin (the donor) to the other (the recipient), which link the two feto-placental circulations. Currently, the only reliable method to measure the net inter-twin transfusion clinically is when incomplete laser therapy of TTTS occurs and one of the twins becomes anemic and requires an intra-uterine transfusion of adult red blood cells. Then, differences between adult hemoglobin concentrations measured during the transfusion and at birth relate not only to the net inter-twin transfusion but also to the finite lifetime of the adult red blood cells. We have analyzed this situation, derived the differential equations of adult hemoglobin in the donor and recipient twins, given the solutions and given expressions relating the net inter-twin flow with clinically measured parameters. We have included single and multiple intra-uterine transfusions. In conclusion, because incomplete laser therapy occurs frequently, and some cases require an intra-uterine transfusion, this method may allow collecting a wealth of net inter-twin flow data from clinicians involved in laser therapy of TTTS. To aid to the widespread use of this method, we have presented the equations as clearly as possible in tables for easy use by others. (note)

  1. Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion

    International Nuclear Information System (INIS)

    Gemert, Martin J C van; Wijngaard, Jeroen P H M van den; Lopriore, Enrico; Pasman, Suzanne A; Vandenbussche, Frank P H A

    2008-01-01

    Twin-twin transfusion syndrome (TTTS) is a severe complication of monozygotic (identical) twin fetuses sharing one single (monochorionic) placenta. TTTS is caused by a net inter-twin transfusion of blood through placental anastomoses, from one twin (the donor) to the other (the recipient), which link the two feto-placental circulations. Currently, the only reliable method to measure the net inter-twin transfusion clinically is when incomplete laser therapy of TTTS occurs and one of the twins becomes anemic and requires an intra-uterine transfusion of adult red blood cells. Then, differences between adult hemoglobin concentrations measured during the transfusion and at birth relate not only to the net inter-twin transfusion but also to the finite lifetime of the adult red blood cells. We have analyzed this situation, derived the differential equations of adult hemoglobin in the donor and recipient twins, given the solutions and given expressions relating the net inter-twin flow with clinically measured parameters. We have included single and multiple intra-uterine transfusions. In conclusion, because incomplete laser therapy occurs frequently, and some cases require an intra-uterine transfusion, this method may allow collecting a wealth of net inter-twin flow data from clinicians involved in laser therapy of TTTS. To aid to the widespread use of this method, we have presented the equations as clearly as possible in tables for easy use by others. (note)

  2. A Novel Stretch Sensor to Measure Venous Hemodynamics

    Directory of Open Access Journals (Sweden)

    Syrpailyne Wankhar

    2018-07-01

    Full Text Available Chronic venous insufficiency is a debilitating condition causing varicose veins and venous ulcers. The pathophysiology includes reflux and venous obstruction. The diagnosis is often made by clinical examination and confirmed by Venous Doppler studies. Plethysmography helps to quantitatively examine the reflux and diagnose the burden of deep venous pathology to better understand venous hemodynamics, which is not elicited by venous duplex examination alone. However, most of these tests are qualitative, expensive, and not easily available. In this paper, we demonstrate the potential use of a novel stretch sensor in the assessment of venous hemodynamics during different maneuvers by measuring the change in calf circumference. We designed the stretch sensor by using semiconductor strain gauges pasted onto a small metal bar to form a load cell. The elastic and Velcro material attached to the load cell form a belt. It converts the change in limb circumference to a proportional tension (force of distension when placed around the calf muscle. We recorded the change in limb circumference from arrays of stretch sensors by using an in-house data acquisition system. We calculated the venous volume (VV, venous filling index (VFI, ejection fraction (EF and residual venous volume (RVV on two normal subjects and on two patients to assess venous hemodynamics. The values (VV > 60 ml, VFI 60%, RVV 2ml/s, EF 35% in patients were comparable to those reported in the literature.

  3. Correlation of Lactic Acid and Base Deficit Values Obtained From Arterial and Peripheral Venous Samples in a Pediatric Population During Intraoperative Care.

    Science.gov (United States)

    Bordes, Brianne M; Walia, Hina; Sebastian, Roby; Martin, David; Tumin, Dmitry; Tobias, Joseph D

    2017-12-01

    Lactic acid and base deficit (BD) values are frequently monitored in the intensive care unit and operating room setting to evaluate oxygenation, ventilation, cardiac output, and peripheral perfusion. Although generally obtained from an arterial cannula, such access may not always be available. The current study prospectively investigates the correlation of arterial and peripheral venous values of BD and lactic acid. The study cohort included 48 patients. Arterial BD values ranged from -8 to 4 mEq/L and peripheral venous BD values ranged from -8 to 4 mEq/L. Arterial lactic acid values ranged from 0.36 to 2.45 μmol/L and peripheral venous lactic acid values ranged from 0.38 to 4 μmol/L. The arterial BD (-0.4 ± 2.2 mEq/L) was not significantly different from the peripheral venous BD (-0.6 ± 2.2 mEq/L). The arterial lactic acid (1.0 ± 0.5 μmol/L) was not significantly different from the peripheral venous lactic acid (1.1 ± 0.6 μmol/L). Pearson correlation coefficients demonstrated a very high correlation between arterial and peripheral venous BD ( r = .88, P lactic acid ( r = .67, P lactic acid corresponded to a 0.9-unit increase in peripheral venous lactic acid (95% CI: 0.6-1.2; P lactic acid and BD values.

  4. Retinal oxygen saturation before and after glaucoma surgery.

    Science.gov (United States)

    Nitta, Eri; Hirooka, Kazuyuki; Shimazaki, Takeru; Sato, Shino; Ukegawa, Kaori; Nakano, Yuki; Tsujikawa, Akitaka

    2017-08-01

    This study compared retinal vessel oxygen saturation before and after glaucoma surgery. Retinal oxygen saturation in glaucoma patients was measured using a non-invasive spectrophotometric retinal oximeter. Adequate image quality was found in 49 of the 108 consecutive glaucoma patients recruited, with 30 undergoing trabeculectomy, 11 EX-PRESS and eight trabeculotomy. Retinal oxygen saturation measurements in the retinal arterioles and venules were performed at 1 day prior to and at approximately 10 days after surgery. Statistical analysis was performed using a Student's t-test. After glaucoma surgery, intraocular pressure (IOP) decreased from 19.8 ± 7.7 mmHg to 9.0 ± 5.7 mmHg (p glaucoma surgery had an effect on the retinal venous oxygen saturation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  5. Evaluation of Optimum Moisture Content for Composting of Beef Manure and Bedding Material Mixtures Using Oxygen Uptake Measurement

    OpenAIRE

    Eunjong Kim; Dong-Hyun Lee; Seunggun Won; Heekwon Ahn

    2016-01-01

    Moisture content influences physiological characteristics of microbes and physical structure of solid matrices during composting of animal manure. If moisture content is maintained at a proper level, aerobic microorganisms show more active oxygen consumption during composting due to increased microbial activity. In this study, optimum moisture levels for composting of two bedding materials (sawdust, rice hull) and two different mixtures of bedding and beef manure (BS, Beef cattle manure+sawdu...

  6. Tailoring the Oxygen Content of Graphite and Reduced Graphene Oxide for Specific Applications.

    Science.gov (United States)

    Morimoto, Naoki; Kubo, Takuya; Nishina, Yuta

    2016-02-25

    Graphene oxide (GO) is widely recognized as a promising material in a variety of fields, but its structure and composition has yet to be fully controlled. We have developed general strategies to control the oxidation degree of graphene-like materials via two methods: oxidation of graphite by KMnO4 in H2SO4 (oGO), and reduction of highly oxidized GO by hydrazine (rGO). Even though the oxygen content may be the same, oGO and rGO have different properties, for example the adsorption ability, oxidation ability, and electron conductivity. These differences in property arise from the difference in the underlying graphitic structure and the type of defect present. Our results can be used as a guideline for the production of tailor-made graphitic carbons. As an example, we show that rGO with 23.1 wt% oxygen showed the best performance as an electrode of an electric double-layer capacitor.

  7. Tailoring the Oxygen Content of Graphite and Reduced Graphene Oxide for Specific Applications

    Science.gov (United States)

    Morimoto, Naoki; Kubo, Takuya; Nishina, Yuta

    2016-02-01

    Graphene oxide (GO) is widely recognized as a promising material in a variety of fields, but its structure and composition has yet to be fully controlled. We have developed general strategies to control the oxidation degree of graphene-like materials via two methods: oxidation of graphite by KMnO4 in H2SO4 (oGO), and reduction of highly oxidized GO by hydrazine (rGO). Even though the oxygen content may be the same, oGO and rGO have different properties, for example the adsorption ability, oxidation ability, and electron conductivity. These differences in property arise from the difference in the underlying graphitic structure and the type of defect present. Our results can be used as a guideline for the production of tailor-made graphitic carbons. As an example, we show that rGO with 23.1 wt% oxygen showed the best performance as an electrode of an electric double-layer capacitor.

  8. Therapeutic effect of forearm low level light treatment on blood flow, oxygenation, and oxygen consumption

    Science.gov (United States)

    Wang, Pengbo; Sun, Jiajing; Meng, Lingkang; Li, Zebin; Li, Ting

    2018-02-01

    Low level light/laser therapy (LLLT) is considered as a novel, non-invasive, and potential therapy in a variety of psychological and physical conditions, due to its effective intricate photobiomodulation. The mechanism of LLLT is that when cells are stimulated by photons, mitochondria produce a large quantity of ATP, which accelerates biochemical responses in the cell. It is of great significance to gain a clear insight into the change or interplay of various physiological parameters. In this study, we used functional near-infrared spectroscopy (fNIRS) and venous-occlusion plethysmography to measure the LLLT-induced changes in blood flow, oxygenation, and oxygen consumption in human forearms in vivo. Six healthy human participants (4 males and 2 females) were administered with 810-nm light emitted by LED array in ten minutes and blood flow, oxygenation and oxygen consumption were detected in the entire experiment. We found that LLLT induced an increase of blood flow and oxygen consumption on the treated site. Meanwhile, LLLT took a good role in promoting oxygenation of regional tissue, which was indicated by a significant increase of oxygenated hemoglobin concentration (Δ[HbO2]), a nearly invariable deoxygenated hemoglobin concentration (Δ[Hb]) and a increase of differential hemoglobin concentration (Δ[HbD] = Δ[HbO2] - Δ[Hb]). These results not only demonstrate enormous potential of LLLT, but help to figure out mechanisms of photobiomodulation.

  9. Oxygen potentials, oxygen diffusion coefficients and defect equilibria of nonstoichiometric (U,Pu)O{sub 2±x}

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Masato, E-mail: kato.masato@jaea.go.jp [Fukushima Fuels and Materials Department, Japan Atomic Energy Agency, 4002 Narita-chou, O-arai machi, Ibaraki 311-1919 (Japan); Fast Reactor Fuel Cycle Technology Development Division, Japan Atomic Energy Agency, 4-33 Muramatsu Tokai-mura, Ibaraki 319-1194 (Japan); Watanabe, Masashi [Fukushima Fuels and Materials Department, Japan Atomic Energy Agency, 4002 Narita-chou, O-arai machi, Ibaraki 311-1919 (Japan); Fast Reactor Fuel Cycle Technology Development Division, Japan Atomic Energy Agency, 4-33 Muramatsu Tokai-mura, Ibaraki 319-1194 (Japan); Matsumoto, Taku; Hirooka, Shun; Akashi, Masatoshi [Fast Reactor Fuel Cycle Technology Development Division, Japan Atomic Energy Agency, 4-33 Muramatsu Tokai-mura, Ibaraki 319-1194 (Japan)

    2017-04-15

    Oxygen potential of (U,Pu)O{sub 2±x} was evaluated based on defect chemistry using an updated experimental data set. The relationship between oxygen partial pressure and deviation x in (U,Pu)O{sub 2±x} was analyzed, and equilibrium constants of defect formation were determined as functions of Pu content and temperature. Brouwer's diagrams were constructed using the determined equilibrium constants, and a relational equation to determine O/M ratio was derived as functions of O/M ratio, Pu content and temperature. In addition, relationship between oxygen potential and oxygen diffusion coefficients were described. - Highlights: •Brouwer’s diagrams for (U,Pu)O2 were constructed using the updated oxygen potential experimental data set. •Equilibrium constants of defect formation were determined as functions of Pu content and temperature. •Oxygen potential, oxygen diffusion coefficients, point defect concentration were described as functions of O/M ratio, Pu content and temperature.

  10. Current concepts in repair of extremity venous injury.

    Science.gov (United States)

    Williams, Timothy K; Clouse, W Darrin

    2016-04-01

    Extremity venous injury management remains controversial. The purpose of this communication is to offer perspective as well as experiential and technical insight into extremity venous injury repair. Available literature is reviewed and discussed. Historical context is provided. Indication, the decision process for repair, including technical conduct, is delineated. In particular, the authors' experiences in both civilian and wartime injury are used for perspective. Extremity venous injury repair was championed within data from the Vietnam Vascular Registry. However, patterns of extremity venous injury differ between combat and civilian settings. Since Vietnam, civilian descriptive series opine the benefits and potential complications associated with both venous injury repair and ligation. These surround extremity edema, chronic venous insufficiency, thromboembolism, and limb loss. Whereas no clear superiority in either approach has been identified to date, there appears to be no increased risk of pulmonary embolism or chronic venous changes with repair. Newer data from the wars in Iraq and Afghanistan and meta-analysis have reinforced this and also have suggested limb salvage benefit for extremity venous repair in combined arterial and venous injuries in modern settings. The patient's physiologic state and associated injury drive five triage categories suggesting vein injury management. Vein repair thrombosis occurs in a significant proportion, yet many recanalize and possibly have a positive impact on limb venous return. Further, early decompression favors reduced blood loss, acute edema, and inflammation, supporting collateral development. Large soft tissue injury minimizing collateral capacity increases the importance of repair. Constructs of repair are varied with modest differences in patency. Venous shunting is feasible, but specific roles remain nebulous. An aggressive posture toward extremity venous injury repair seems justified today because of the likely

  11. Cerebral oxygen delivery is reduced in newborns with congenital heart disease.

    Science.gov (United States)

    Lim, Jessie Mei; Kingdom, Theodore; Saini, Brahmdeep; Chau, Vann; Post, Martin; Blaser, Susan; Macgowan, Christopher; Miller, Steven P; Seed, Mike

    2016-10-01

    To investigate preoperative cerebral hemodynamics in newborns with congenital heart disease. We hypothesized that cerebral blood flow and oxygen delivery would be decreased in newborns with congenital heart disease compared with controls. Using a "feed-and-sleep" approach to performing neonatal magnetic resonance imaging, we measured cerebral blood flow by using a slice prescription perpendicular to the right and left internal carotid arteries and basilar artery at the level of the clivus. We calculated brain volume by segmenting a 3-dimensional steady-state free procession acquisition of the whole brain, allowing quantification of cerebral blood flow indexed to brain volume. Cerebral oxygen delivery was calculated as the product of cerebral blood flow and preductal systemic arterial oxygen content obtained via a combination of conventional pulse oximetry and laboratory analysis of venous blood samples for hemoglobin concentration. A complete set of measurements were obtained in 32 newborns with heart disease and 31 controls. There was no difference in gestational age between the heart disease and control groups. There was no difference in cerebral blood flow compared with controls (103.5 ± 34.0 vs 119.7 ± 40.4 mL/min), whereas cerebral oxygen delivery was significantly lower in the congenital heart disease subjects (1881 ± 625.7 vs 2712 ± 915.7 mLO2/min). Ten newborns with congenital heart disease had diffuse excessive high signal intensity in their white matter and 2 had white matter injury whereas another 5 had both. Newborns with unrepaired cyanotic congenital heart disease have decreased cerebral oxygen delivery due to arterial desaturation. If brain growth and development are adversely affected through oxygen conformance, our findings could have clinical implications in terms of timing of surgical repair. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  12. The influence of systemic hemodynamics and oxygen transport on cerebral oxygen saturation in neonates after the Norwood procedure.

    Science.gov (United States)

    Li, Jia; Zhang, Gencheng; Holtby, Helen; Guerguerian, Anne-Marie; Cai, Sally; Humpl, Tilman; Caldarone, Christopher A; Redington, Andrew N; Van Arsdell, Glen S

    2008-01-01

    Ischemic brain injury is an important morbidity in neonates after the Norwood procedure. Its relationship to systemic hemodynamic oxygen transport is poorly understood. Sixteen neonates undergoing the Norwood procedure were studied. Continuous cerebral oxygen saturation was measured by near-infrared spectroscopy. Continuous oxygen consumption was measured by respiratory mass spectrometry. Pulmonary and systemic blood flow, systemic vascular resistance, oxygen delivery, and oxygen extraction ratio were derived with measurements of arterial, and superior vena cava and pulmonary venous gases and pressures at 2- to 4-hour intervals during the first 72 hours in the intensive care unit. Mean cerebral oxygen saturation was 66% +/- 12% before the operation, reduced to 51% +/- 13% on arrival in the intensive care unit, and remained low during the first 8 hours; it increased to 56% +/- 9% at 72 hours, still significantly lower than the preoperative level (P blood flow and oxygen delivery (P blood flow (P = .001) and hemoglobin (P = .02) and negatively correlated with systemic vascular resistance (P = .003). It was not correlated with oxygen consumption (P > .05). Cerebral oxygen saturation decreased significantly in neonates during the early postoperative period after the Norwood procedure and was significantly influenced by systemic hemodynamic and metabolic events. As such, hemodynamic interventions to modify systemic oxygen transport may provide further opportunities to reduce the risk of cerebral ischemia and improve neurodevelopmental outcomes.

  13. Cerebral venous thrombosis

    International Nuclear Information System (INIS)

    Soralova, T.; Sevcikova, H.; Petersky, D.

    2014-01-01

    We decided to process this theme due to its nonspecific clinical features as they often cause diagnostic problems not only to clinicians but also to diagnostic. It is important to think of this disease mainly in young women who administer hormonal contraception. Imaging methods play the crucial role in diagnostic of cerebral venous sinus thrombosis. The gold standard is a native CT of brain which shows the venous sinus thrombosis as a hyperdense lesion in the locus of the sinus (dense triangle sign), CT venography shows the sinus thrombosis as a defect in a contrast filling of the venous sinus (empty delta sign). Other investigative methods are magnetic resonance imaging or MRA. In short we also mention quite a rare but more serious thrombosis of profound cerebral veins v. cerebri magna-Galeni, vv. cerebri internae). The importance of early diagnostic and non specificity of symptoms is presented in 3 clinical cases that are the part of this work. (author)

  14. Minimally invasive prediction of ScvO2 in high-risk surgery : The introduction of a model Index of Oxygenation

    NARCIS (Netherlands)

    de Grooth, Harm-Jan S.; Vos, Jaap Jan; Scheeren, Thomas; van Beest, Paul

    2014-01-01

    INTRODUCTION: The purpose of this study was to examine the trilateral relationship between cardiac index (CI), tissue oxygen saturation (StO2) and central venous oxygen saturation (ScvO2) and subsequently develop a model to predict ScvO2 on minimal invasive manner in patients undergoing major

  15. Human cerebral venous outflow pathway depends on posture and central venous pressure

    Science.gov (United States)

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  16. Penile venous surgery for treating erectile dysfunction: Past, present, and future perspectives with regard to new insights in venous anatomy

    Directory of Open Access Journals (Sweden)

    Cheng-Hsing Hsieh

    2016-06-01

    Full Text Available In the physiologic model of normal erectile function, a healthy veno-occlusive mechanism is essential to initiate and maintain a rigid erection. The surgical treatment of patients with venous leakage, which is synonymous with corporoveno-occlusive dysfunction (CVOD, was based on the decreased venous outflow during the erection process. The initial reports of short-term results were promising, but the long-term benefits of penile venous ligation surgery were limited. Most clinical guideline panels concluded that surgeries performed in an attempt to limit the venous outflow of the penis were not recommended. Consequently, this surgery was nearly abandoned in most medical societies worldwide. These unfavorable postoperative outcomes seemed attributable to the indispensable usage of electrocautery and insufficient venous management, based on conventional penile venous anatomy. Advances in better understanding of human penile venous anatomy has enabled the development of refined penile venous stripping surgery. The thorough stripping surgery is an even more radical procedure, which is an even more radical procedure, and seems to be a viable option for the treatment of CVOD, however, there is still a need for further study with well-defined diagnostic criteria, and standardized patient and partner outcome assessment.

  17. Cerebral venous outflow and cerebrospinal fluid dynamics

    Directory of Open Access Journals (Sweden)

    Clive B. Beggs

    2014-12-01

    Full Text Available In this review, the impact of restricted cerebral venous outflow on the biomechanics of the intracranial fluid system is investigated. The cerebral venous drainage system is often viewed simply as a series of collecting vessels channeling blood back to the heart. However there is growing evidence that it plays an important role in regulating the intracranial fluid system. In particular, there appears to be a link between increased cerebrospinal fluid (CSF pulsatility in the Aqueduct of Sylvius and constricted venous outflow. Constricted venous outflow also appears to inhibit absorption of CSF into the superior sagittal sinus. The compliance of the cortical bridging veins appears to be critical to the behaviour of the intracranial fluid system, with abnormalities at this location implicated in normal pressure hydrocephalus. The compliance associated with these vessels appears to be functional in nature and dependent on the free egress of blood out of the cranium via the extracranial venous drainage pathways. Because constricted venous outflow appears to be linked with increased aqueductal CSF pulsatility, it suggests that inhibited venous blood outflow may be altering the compliance of the cortical bridging veins.

  18. Supercritical CO2 Extraction of Lavandula angustifolia Mill. Flowers: Optimisation of Oxygenated Monoterpenes, Coumarin and Herniarin Content.

    Science.gov (United States)

    Jerković, Igor; Molnar, Maja; Vidović, Senka; Vladić, Jelena; Jokić, Stela

    2017-11-01

    Lavandula angustifolia is good source of oxygenated monoterpenes containing coumarins as well, which are all soluble in supercritical CO 2 (SC-CO 2 ). The study objective is to investigate SC-CO 2 extraction parameters on: the total yield; GC-MS profile of the extracts; relative content of oxygenated monoterpenes; the amount of coumarin and herniarin; and to determine optimal SC-CO 2 extraction conditions by response surface methodology (RSM). SC-CO 2 extraction was performed under different pressure, temperature and CO 2 flow rate determined by Box-Behnken design (BBD). The sample mass and the extraction time were kept constant. The chemical profiles and relative content of oxygenated monoterpenes (as coumarin equivalents, CE) were determined by GC-MS. Coumarin and herniarin concentrations were dosed by HPLC. SC-CO 2 extracts contained linalool (57.4-217.9 mg CE/100 g), camphor (10.6-154.4 mg CE/100 g), borneol (6.2-99.9 mg CE/100 g), 1,8-cineole (5.0-70.4 mg CE/100 g), linalyl acetate (86.1-267.9 mg CE/100 g), coumarin (0.95-18.16 mg/100 g), and herniarin (0.95-13.63 mg/100 g). The interaction between the pressure and CO 2 flow rate as well as between the temperature and CO 2 flow rate showed statistically significant influence on the extraction yield. Applying BBD, the optimum extraction conditions for higher monoterpenes and lower coumarin content were at 10 MPa, 41°C and CO 2 flow rate 2.3 kg/h, and at 30 MPa, 50°C and CO 2 flow rate 3 kg/h for higher monoterpenes and coumarin content. SC-CO 2 extraction is a viable technique for obtaining lavender extracts with desirable flavour components. The second-order model based on BBD predicts the results for SC-CO 2 extraction quite satisfactorily. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Leukocytic Response and Peripheral Venous Blood Lymphocyte Apoptosis as a Marker of Tissue Ischemia in Acute Massive Blood Loss

    Directory of Open Access Journals (Sweden)

    N. V. Borovkova

    2013-01-01

    Full Text Available Objective: to estimate the level of peripheral venous blood lymphocyte apoptosis and intraoperative hypoxia in victims with acute massive blood loss. Subjects and methods. Twenty-two patients with open and close chest and abdominal traumas complicated by acute massive blood loss were examined. All the patients were emergently operated on to stop bleeding. Tissue metabolism was evaluated from gases, acid-base parameters, and plasma lactate, glucose, potassium, and sodium levels. Apoptosis of mononuclear cells was studied and dead leukocytes were counted using flow cytometry. Results. Preoperatively, the victims were found to have venous hypoxemia, hyperlactatemia, hyperglycemia, moderate leukocytosis, and higher dead leukocyte counts. There were also raised counts of lymphocytes coming into the process of apoptosis. A significant relationship was found between monocyte counts and hypoxia values. At the end of surgery, oxygen balance values became stable and exerted an effect on the count of leukocytes, the relative level of granulocytes, the relative and absolute counts of dead and damaged leukocytes, and the concentration of lymphocytes in the victims’ venous blood during the early stages of apoptosis, as evidenced by nonlinear regression models. Conclusion. The indicators of immunocompetent cell apoptosis and the count of venous blood dead leukocytes along with lactate levels and venous hypoxemia parameters reflect the degree of tissue hypoxia and may be used as specific markers.

  20. Development and validation of educational technology for venous ulcer care.

    Science.gov (United States)

    Benevides, Jéssica Lima; Coutinho, Janaina Fonseca Victor; Pascoal, Liliane Chagas; Joventino, Emanuella Silva; Martins, Mariana Cavalcante; Gubert, Fabiane do Amaral; Alves, Allana Mirella

    2016-04-01

    To develop and validate an educational technology venous ulcers care. Methodological study conducted in five steps: Situational diagnosis; literature review; development of texts, illustrations and layout; apparent and content validity by the Content Validity Index, assessment of Flesch Readability Index; and pilot testing. The developed technology was a type of booklet entitled Booklet for Venous Ulcers Care, consisting of seven topics: Diet and food intake, walking and light exercise, resting with elevated leg, bandage care, compression therapy, family support, and keeping healthy habits. The apparent validity revealed minimal agreement of 85.7% in the clarity and comprehensibility. The total content validity index was 0.97, the Flesch Readability Index was 75%, corresponding to the reading "fairly easy". The pilot test showed that 100% of people with venous ulcers evaluated the text and the illustrations as understandable, as appropriate. The educational technology proved to be valid for the appearance and content with potential for use in clinical practice. Construir e validar uma tecnologia educativa para cuidados com úlcera venosa. Estudo metodológico realizado em cinco fases: diagnóstico situacional; revisão da literatura; desenvolvimento de textos, ilustrações e diagramação; validade de aparência e de conteúdo pelo Índice de Validade de Conteúdo, avaliação do Índice de Legibilidade de Flesch; e teste piloto. A tecnologia desenvolvida foi do tipo cartilha intitulada Cartilha para cuidados com úlcera venosa, constituída de sete tópicos: Alimentação, Caminhadas e exercícios leves, Repouso com a perna elevada, Cuidados com o curativo, Terapia compressiva, Apoio familiar, e manter hábitos saudáveis. A validade aparente revelou concordância mínima de 85,7% na clareza e compreensibilidade. O Índice de Validade de Conteúdo total foi de 0,97, o Índice de legibilidade de Flesch foi de 75%, o que correspondeu à leitura "razoavelmente f

  1. Chronic venous disease.

    Science.gov (United States)

    Wolinsky, Claire D; Waldorf, Heidi

    2009-11-01

    Identifying characteristic cutaneous findings is important in determining the appropriate management of certain venous diseases. The health care provider should be familiar with the classic description of patterns and distributions of skin manifestations, such as varicose veins, stasis dermatitis, palpable cord, petechiae, and telangiectasias. In addition to the gross appearance of the skin, a skin biopsy may help elucidate a diagnosis. General treatment and prevention of the underlying venous pathology is essential. Furthermore, specific management of skin findings should include therapy to ameliorate progression of disease and symptomatology when warranted.

  2. Central Venous Access

    International Nuclear Information System (INIS)

    Ganeshan, Arul; Warakaulle, Dinuke R.; Uberoi, Raman

    2007-01-01

    Central venous access plays an important role in the management of an ever-increasing population of patients ranging from those that are critically ill to patients with difficult clinical access. Interventional radiologists are key in delivering this service and should be familiar with the wide range of techniques and catheters now available to them. A comprehensive description of these catheters with regard to indications, technical aspects of catheterization, success rates, and associated early and late complications, as well as a review of various published guidelines on central venous catheter insertion are given in this article

  3. Characterization of hemodynamics and oxygenation in the renal cortex of rats

    Science.gov (United States)

    Grosenick, Dirk; Wabnitz, Heidrun; Macdonald, Rainer; Niendorf, Thoralf; Cantow, Kathleen; Flemming, Bert; Arakelyan, Karen; Seeliger, Erdmann

    2015-03-01

    We have performed a pre-clinical study on 13 rats to investigate the potential of near-infrared spectroscopy for quantification of hemoglobin concentration and oxygen saturation of hemoglobin in the renal cortex of small animals. These measurements were combined with laser-Doppler fluxmetry and a fluorescence quenching technique for quantification of tissue oxygen tension. Hemoglobin concentration and oxygen saturation were determined from experimental data by a Monte Carlo model. The methods were applied to investigate and compare temporal changes during several types of interventions such as arterial and venous occlusions, as well as hyperoxia, hypoxia and hypercapnia induced by different mixtures of the inspired gas.

  4. Optimization of uranium carbide fabrication by carbothermic reduction with limited oxygen content

    International Nuclear Information System (INIS)

    Raveu, Gaelle

    2014-01-01

    Mixed carbides (U, Pu)C, are good fuel candidate for generation IV reactors because of their high fissile atoms density and excellent thermal properties for economical (more compact and efficient cores) and safety reasons (high melting margin). UC can be imagine as a surrogate material ror R and D studies on (U,Pu)C fuel behavior, because of their similar structures. The carbothermic reaction was used because it is the most studied and now consider for industrial process. However, it involves powders manipulation: in air, carbide can strongly react at room temperature and under controlled atmosphere it can absorb impurities. An inerted installation under Ar, BaGCARA, was therefore used. Process improvements were carried out, including the sintering atmosphere in order to evaluate the impact on the sample purity (about oxygen content). The original method by ion beam analysis was used to determine the surface composition (oxygen in-depth profiles in the first microns and stoichiometry). This oxygen analysis was set for the first time in carbonaceous materials. XRD analysis showed the formation of an intermediate compound during the carbothermic reaction and a better crystallization of the samples fabricated in BaGCARA. They also have a better microstructure, density, and visual appearance if compared to former samples. Vacuum sintering leads to a denser UC with fewer second phases if compared to Ar, Ar/H 2 or controlled PC atmospheres. However, it was not possible to analyze carbides without air contact which may impact their lattice parameter and lead to their deterioration. When the carbide is initially free of oxygen, it oxidizes faster, more intensely and heterogeneously. The mechanical stress induced between the grains lead to fracturing the material, to corrosion cracking and then a de-bonding of the material. A study of oxidation mechanisms would be interesting to validate and understand the evolution of the material in contact with oxygen. A study of the

  5. Cerebral Venous Thrombosis and Venous Infarction: Case Report of a Rare Initial Presentation of Smoker’s Polycythemia

    Directory of Open Access Journals (Sweden)

    Mihir Raval

    2010-11-01

    Full Text Available Introduction: Cerebral venous thrombosis is a rare initial presentation of polycythemia. If diagnosed early, treatment can reduce mortality and morbidity significantly. Often it may present with headache as the only complaint, and thus the diagnosis is likely to be missed. Case Presentation: A medically stable 31-year-old male, a chronic smoker with a ∼17 pack-year history of smoking, was admitted to the emergency room with a 2-week history of gradually worsening, severe, throbbing headache in the occipital region sensitive to light. Initial neurological examination was positive only for some involuntary motor tics of the left leg. Initial laboratory workup showed hemoglobin of 20 g/dl and hematocrit of 56.5%. The carboxyhemoglobin level was normal, but the oxygen dissociation curve was shifted to the left. Further evaluation by MRI and MRA of the brain suggested extensive and complete thrombosis of the superior sagittal sinus, right transverse sinus and right sigmoid sinus with a small venous infarct in the right parafrontal region. Given that the patient first presented with a thrombotic event, workup for primary polycythemia and hypercoagulable disorders was carried out, including JAK2 mutation evaluation, which was negative. This left us with smoking as the only risk factor and possible cause for secondary polycythemia. He improved significantly with phlebotomy and anticoagulation treatment. Conclusion: This case illustrates a rare but severe complication of secondary polycythemia stressing the importance of being aware of the risk of developing cerebral thrombosis in patients with chronic smoking exposure.

  6. Radiologically-placed venous ports in children under venous anesthesia

    International Nuclear Information System (INIS)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak

    2015-01-01

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  7. Radiologically-placed venous ports in children under venous anesthesia

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak [Pusan National University School of Medicine, Yangsan (Korea, Republic of)

    2015-02-15

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  8. Brain magnetic resonance imaging with contrast dependent on blood oxygenation

    International Nuclear Information System (INIS)

    Ogawa, S.; Lee, T.M.; Kay, A.R.; Tank, D.W.

    1990-01-01

    Paramagnetic deoxyhemoglobin in venous blood is a naturally occurring contrast agent for magnetic resonance imaging (MRI). By accentuating the effects of this agent through the use of gradient-echo techniques in high yields, the authors demonstrate in vivo images of brain microvasculature with image contrast reflecting the blood oxygen level. This blood oxygenation level-dependent (BOLD) contrast follows blood oxygen changes induced by anesthetics, by insulin-induced hypoglycemia, and by inhaled gas mixtures that alter metabolic demand or blood flow. The results suggest that BOLD contrast can be used to provide in vivo real-time maps of blood oxygenation in the brain under normal physiological conditions. BOLD contrast adds an additional feature to magnetic resonance imaging and complement other techniques that are attempting to provide position emission tomography-like measurements related to regional neural activity

  9. The effect of reduced oxygen content powder on the impact toughness of 316 steel powder joined to 316 steel by low temperature HIP

    International Nuclear Information System (INIS)

    Lind, Anders; Sundstroem, Johan; Peacock, Alan

    2005-01-01

    During the manufacture of the blanket modules, 316L steel powder is simultaneously consolidated and joined to tubes and blocks of 316L materials by hot isostatic pressing (HIP). The high processing temperature can detrimentally increase the grain size of the water-cooling tubes in the structure and the blocks reducing their strength. It is well known [L. Arnberg, A. Karlsson, Influence of powder surface oxidation on some properties of a HIPed martensitic chromium steel, Int. J. Powder Metall. 24 (2) (1988) 107-112] that surface oxides on the powder particles negatively influence the impact toughness of material and joints consolidated in this way. At a high HIP temperature, the oxides are at least partly transformed, thereby improving the impact toughness [L. Nyborg, I. Olefjord, Surface analysis of PM martensitic steel before and after consolidation. Part 2. Surface analysis of compacted material, Powder Metall. 31 (1) (1988) 40-44]. In order to get acceptable mechanical properties of materials produced at a low HIP temperature, the oxygen content on the powder surfaces needs to be reduced. In order to study the effect of reducing the powder oxygen content, it was reduced and the results were compared to those of specimens with ordinary oxygen content. The effect on the impact toughness and the tensile strength of low temperature (1020 and 1060 deg. C) HIP joints between steel blocks and powder consolidated material with low and ordinary oxygen content was measured

  10. Changes in retinal oxygen saturation after intravitreal aflibercept in patients with diabetic macular edema

    DEFF Research Database (Denmark)

    Blindbæk, Søren Leer; Peto, Tunde; Grauslund, Jakob

    2017-01-01

    Design of study: Three months prospective interventional study. Purpose: To evaluate changes in retinal arterial and venous oxygen saturation after intravitreal aflibercept in patients with diabetic macular edema (DME). Methods: We included 17 patients with DME, central retinal thickness (CRT) >300...

  11. The impact of oxygen on the final alcohol content of wine fermented by a mixed starter culture.

    Science.gov (United States)

    Morales, Pilar; Rojas, Virginia; Quirós, Manuel; Gonzalez, Ramon

    2015-05-01

    We have developed a wine fermentation procedure that takes advantage of the metabolic features of a previously characterized Metschnikowia pulcherrima strain in order to reduce ethanol production. It involves the use of M. pulcherrima/Saccharomyces cerevisiae mixed cultures, controlled oxygenation conditions during the first 48 h of fermentation, and anaerobic conditions thereafter. The influence of different oxygenation regimes and initial inoculum composition on yeast physiology and final ethanol content was studied. The impact of oxygenation on yeast physiology goes beyond the first aerated step and influences yields and survival rates during the anaerobic stage. The activity of M. pulcherrima in mixed oxygenated cultures resulted in a clear reduction in ethanol yield, as compared to S. cerevisiae. Despite relatively low initial cell numbers, S. cerevisiae always predominated in mixed cultures by the end of the fermentation process. Strain replacement was faster under low oxygenation levels. M. pulcherrima confers an additional advantage in terms of dissolved oxygen, which drops to zero after a few hours of culture, even under highly aerated conditions, and this holds true for mixed cultures. Alcohol reduction values about 3.7 % (v/v) were obtained for mixed cultures under high aeration, but they were associated to unacceptable volatile acidity levels. In contrast, under optimized conditions, only 0.35 g/L acetic acid was produced, for an alcohol reduction of 2.2 % (v/v), and almost null dissolved oxygen during the process.

  12. Venous thromboembolism and arterial complications.

    Science.gov (United States)

    Prandoni, Paolo; Piovella, Chiara; Pesavento, Raffaele

    2012-04-01

    An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, smoking, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Simulating the oxygen content of ambient organic aerosol with the 2D volatility basis set

    Directory of Open Access Journals (Sweden)

    B. N. Murphy

    2011-08-01

    Full Text Available A module predicting the oxidation state of organic aerosol (OA has been developed using the two-dimensional volatility basis set (2D-VBS framework. This model is an extension of the 1D-VBS framework and tracks saturation concentration and oxygen content of organic species during their atmospheric lifetime. The host model, a one-dimensional Lagrangian transport model, is used to simulate air parcels arriving at Finokalia, Greece during the Finokalia Aerosol Measurement Experiment in May 2008 (FAME-08. Extensive observations were collected during this campaign using an aerosol mass spectrometer (AMS and a thermodenuder to determine the chemical composition and volatility, respectively, of the ambient OA. Although there are several uncertain model parameters, the consistently high oxygen content of OA measured during FAME-08 (O:C = 0.8 can help constrain these parameters and elucidate OA formation and aging processes that are necessary for achieving the high degree of oxygenation observed. The base-case model reproduces observed OA mass concentrations (measured mean = 3.1 μg m−3, predicted mean = 3.3 μg m−3 and O:C (predicted O:C = 0.78 accurately. A suite of sensitivity studies explore uncertainties due to (1 the anthropogenic secondary OA (SOA aging rate constant, (2 assumed enthalpies of vaporization, (3 the volatility change and number of oxygen atoms added for each generation of aging, (4 heterogeneous chemistry, (5 the oxidation state of the first generation of compounds formed from SOA precursor oxidation, and (6 biogenic SOA aging. Perturbations in most of these parameters do impact the ability of the model to predict O:C well throughout the simulation period. By comparing measurements of the O:C from FAME-08, several sensitivity cases including a high oxygenation case, a low oxygenation case, and biogenic SOA aging case are found to unreasonably depict OA aging, keeping in mind that this study does not consider

  14. Venous trauma in the Lebanon War--2006.

    Science.gov (United States)

    Nitecki, Samy S; Karram, Tony; Hoffman, Aaron; Bass, Arie

    2007-10-01

    Reports on venous trauma are relatively sparse. Severe venous trauma is manifested by hemorrhage, not ischemia. Bleeding may be internal or external and rarely may lead to hypovolemic shock. Repair of major extremity veins has been a subject of controversy and the current teaching is to avoid venous repair in an unstable or multi-trauma patient. The aim of the current paper is to present our recent experience in major venous trauma during the Lebanon conflict, means of diagnosis and treatment in a level I trauma center. All cases of major venous trauma, either isolated or combined with arterial injury, admitted to the emergency room during the 33-day conflict were reviewed. Out of 511 wounded soldiers and civilians who were admitted to our service over this period, 12 (2.3%) sustained a penetrating venous injury either isolated (5) or combined with arterial injury (7). All injuries were secondary to high velocity penetrating missiles or from multiple pellets stored in long-range missiles. All injuries were accompanied by additional insult to soft tissue, bone and viscera. The mean injury severity score was 15. Severe external bleeding was the presenting symptom in three cases of isolated venous injury (jugular, popliteal and femoral). The diagnosis of a major venous injury was made by a CTA scan in five cases, angiography in one and during surgical exploration in six cases. All injured veins were repaired: three by venous interposition grafts, four by end to end anastomosis, three by lateral suture and two by endovascular techniques. None of the injuries was treated by ligation of a major named vein. Immediate postoperative course was uneventful in all patients and the 30-day follow-up (by clinical assessment and duplex scan) has demonstrated a patent repair with no evidence of thrombosis. Without contradicting the wisdom of ligating major veins in the setup of multi-trauma or an unstable patient, our experience indicates that a routine repair of venous trauma can

  15. Venous infraction of developmental venous anomaly: A case report with perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Youn; Kim, Hye Jeong; Hyun, Su Jeong; Kim, Hee Yeong; Kim, Han Myun; Hwang, Ji Young; Hong, Hye Suk; Woo, Ji Young; Yang, Ik [Dept. of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Kim, Eun Soo [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2017-06-15

    Developmental venous anomaly (DVA) is a common congenital venous malformation characterized by dilated medullary veins in caput medusa configuration and a draining vein. Despite the high incidence of DVAs, they are benign anatomic variations and rarely cause symptoms. Here, we report computed tomography and magnetic resonance imaging findings with perfusion images of acute infarction from underlying DVA in a 63-year-old female patient who presented with acute onset of neurologic symptoms and recovered without any neurologic deficit.

  16. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest......Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position...

  17. Effects of carvedilol and propranolol on circulatory regulation and oxygenation in cirrhosis

    DEFF Research Database (Denmark)

    Hobolth, Lise; Bendtsen, Flemming; Hansen, Erik F

    2014-01-01

    =16) or propranolol (n=13). Cardiac, systemic and splanchnic parameters along with oxygen saturation and plasma renin were measured at inclusion and after 3 months. RESULTS: Arterial blood pressure, heart rate, and cardiac output decreased equally, central circulation time and systemic vascular...... oxygen gradient remained constant in both groups. Hepatic venous pressure gradient decreased equally in the carvedilol and propranolol groups (-17% and -20%, non significant). CONCLUSIONS: Systemic haemodynamics and pulmonary effects of carvedilol and propranolol are modest and this study could...

  18. The impact of including spatially longitudinal heterogeneities of vessel oxygen content and vascular fraction in 3D tumor oxygenation models on predicted radiation sensitivity.

    Science.gov (United States)

    Lagerlöf, Jakob H; Kindblom, Jon; Bernhardt, Peter

    2014-04-01

    from 0% to 97%, and a maximal D99 increment of 57%. Only minor differences were observed between different vessel architectures, i.e., CVF vs VVF. In the smallest tumor with a low necrotic fraction, the D99 strictly decreased with increasing blood velocity. Increasing blood velocity also decreased the necrotic fraction in all tumor sizes. VF had the most profound influence on both the necrotic fraction and on D99. Our present analysis of necrotic formation and the impact of tumor oxygenation on D99 demonstrated the importance of including longitudinal variations in vessel oxygen content in tumor models. For small tumors, radiosensitivity was particularly dependent on VF and slightly dependent on the blood velocity and vessel arrangement. These dependences decreased with increasing tumor size, because the necrotic fraction also increased, thereby decreasing the number of viable tumor cells that required sterilization. The authors anticipate that the present model will be useful for estimating tumor oxygenation and radiation response in future detailed studies. © 2014 American Association of Physicists in Medicine.

  19. A multimodality regimen for deep venous thrombosis prophylaxis in total knee arthroplasty.

    Science.gov (United States)

    Reitman, Richard D; Emerson, Roger H; Higgins, Linda L; Tarbox, Tiffera R

    2003-02-01

    Data indicate that deep venous thrombosis (DVT) occurs at the time of knee arthroplasty. Nevertheless, literature concerning DVT prophylaxis has only recently addressed this contention. This prospective study evaluated the efficacy of a perioperative prophylactic regimen. Between January 1996 and June 2001, 1,308 knees (964 surgeries) underwent total knee arthroplasty. Patients were treated routinely with intraoperative heparin (1000 units intravenous push before inflation of the tourniquet and 500 units at deflation), hypotensive epidural anesthesia (MAP 70-90), external pneumatic compression boots, and aspirin (325 mg, PO, BID for 6 weeks). Duplex venous ultrasonography was performed before discharge. DVT was detected in 4% of cases (1% proximal and 3% distal). Bleeding complications occurred in 1%, and perioperative medical complications occurred in 12%. Copyright 2003, Elsevier Science (USA). All rights reserved.

  20. Chronic Venous Disease under pressure

    NARCIS (Netherlands)

    S.W.I. Reeder (Suzan)

    2013-01-01

    textabstractIn chapter 1 we provide a general introduction of this thesis. Chronic venous disease (CVD) is a common medical condition that affects 2-64% of the worldwide population and leads to leg ulcers in 1% of the Western population. Venous leg ulceration (VLU) has an unfavorable prognosis with

  1. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  2. Influence of Food with High Moisture Content on Oxygen Barrier Property of Polyvinyl Alcohol (PVA)/Vermiculite Nanocomposite Coated Multilayer Packaging Film.

    Science.gov (United States)

    Kim, Jung Min; Lee, Min Hyeock; Ko, Jung A; Kang, Dong Ho; Bae, Hojae; Park, Hyun Jin

    2018-02-01

    This study investigates the potential complications in applying nanoclay-based waterborne coating to packaging films for food with high moisture content. Multilayer packaging films were prepared by dry laminating commercially available polyvinyl alcohol (PVA)/vermiculite nanocomposite coating films and linear low-density polyethylene film, and the changes in oxygen barrier properties were investigated according to different relative humidity using 3 types of food simulants. When the relative humidity was above 60%, the oxygen permeability increased sharply, but this was reversible. Deionized water and 3% acetic acid did not cause any large structural change in the PVA/vermiculite nanocomposite but caused a reversible deterioration of the oxygen barrier properties. In contrast, 50% ethanol, a simulant for the semifatty food, induced irreversible structural changes with deterioration of the oxygen barrier property. These changes are due to the characteristics of PVA rather than vermiculite. We believe this manuscript would be of interest to the wide group of researchers, organizations, and companies in the field of developing nanoclay-based gas barrier packaging for foods with high moisture content. Hence, we wish to diffuse our knowledge to the scientific community. © 2018 Institute of Food Technologists®.

  3. Surgical management of venous malformations.

    Science.gov (United States)

    Loose, D A

    2007-01-01

    Among vascular malformations, the predominantly venous malformations represent the majority of cases. They form a clinical entity and therefore need clear concepts concerning diagnosis and treatment. This paper presents an overview of contemporary classification as well as tactics and techniques of treatment. According to the Hamburg Classification, predominantly venous malformations are categorized into truncular and extratruncular forms, with truncular forms distinguished as obstructions and dilations, and extratruncular forms as limited or infiltrating. The tactics of treatment represent surgical and non-surgical methods or combined techniques. Surgical approaches utilize different tactics and techniques that are adopted based on the pathologic form and type of the malformation: (I) operation to reduce the haemodynamic activity of the malformation; (II) operation to eliminate the malformation; and (III) reconstructive operation. As for (I), a type of a tactic is the operation to derive the venous flow. In (II), the total or partial removal of the venous malformation is demonstrated subdivided into three different techniques. In this way, the infiltrating as well as the limited forms can be treated. An additional technique is dedicated to the treatment of a marginal vein. Approach (III) involves the treatment of venous aneurysms, where a variety of techniques have been successful. Long-term follow-up demonstrates positive results in 91% of the cases. Congenital predominantly venous malformations should be treated according to the principles developed during the past decades in vascular surgery, interventional treatment and multidisciplinary treatment. The days of predominantly conservative treatment should be relegated to the past. Special skills and experiences are necessary to carry out appropriate surgical strategy, and the required operative techniques should be dictated by the location and type of malformation and associated findings.

  4. Anaerobic energy production and O2 deficit-debt relationship during exhaustive exercise in humans

    DEFF Research Database (Denmark)

    Bangsbo, Jens; Gollnick, PD; Graham, T

    1990-01-01

    oxygen uptake, heart rate, blood pressure, leg blood flow, and femoral arterial-venous differences of oxygen content and lactate were performed as well as determination of ATP, creatine phosphate (CP) inosine monophosphate (IMP) and lactate concentrations on biopsy material from the quadriceps muscle...

  5. Prevalence of lower extremity venous duplication

    Directory of Open Access Journals (Sweden)

    Simpson William

    2010-01-01

    Full Text Available Purpose: This retrospective study was performed to determine the prevalence of lower extremity venous duplication using duplex ultrasound in the patient population of a large urban medical center. Materials and Methods: The reports of all lower extremity venous ultrasound examinations performed at our institution between January 1, 2002 and December 31, 2002 were reviewed. Ultrasound examinations that were performed for purposes other than the detection of lower extremity deep vein thrombosis were excluded. The prevalence of duplication and its specific location were recorded. In addition, the prevalence of thrombus and its specific location were also recorded. Results: A total of 3118 exams were performed in 2664 patients. Of the 2664 patients, 2311 had only one examination performed during the study period; 353 patients had more than one examination performed. We found that 10.1% of patients (270/2664 had at least one venous segment duplicated and 5.4% of patients (143/2664 had a thrombus in at least one venous segment. There was a statistically significant difference in the prevalence of both duplication and thrombus with a change in venous segment. Only 0.4% of patients (11/2664 had thrombus within a duplicated segment. Of those who had more than one examination performed, 15.3% (54/353 had the same venous segment(s seen on one examination but not another. Conclusion: Lower extremity venous duplication is a frequent anatomic variant that is seen in 10.1% of patients, but it may not be as common as is generally believed. It can result in a false negative result for deep vein thrombosis.

  6. Ischemic stroke in combined cerebrovascular abnormalities - aneurysm of the right internal carotid artery and arteriovenous malformation temporo occipital in the right hemisphere

    International Nuclear Information System (INIS)

    Manolova, T.; Naydenov, K.; Manchev, I.; Manchev, L.

    2016-01-01

    A case of combined vascular abnormalities is presented- an aneurysm of the internal carotid artery and arterio-venous malformation temporooccipitally on the right, clinically presented by an ischemic brain stroke in the territory supplied by the right middle cerebral artery. Treatment included - hypo-tensive drugs, antiplatelet (antiaggregants) agents and vasodilators, which lead to significant improvement of the general and focal neurological symptoms. Neurosurgical intervention is been discussed, in order to remove the vascular malformation and to prevent future vascular events. Key words: Aneurysm. Arteriovenous Malformation. Ischemic Stroke

  7. Emergency endovascular management of peripheral artery aneurysms and pseudoaneurysms – a review

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Endovascular stenting has been successfully employed in the management of aortic aneurysms; however, its use in managing peripheral arterial conditions remains questionable. We review the utility of endovascular technique in the management of peripheral arterial conditions like aneurysms, pseudoaneurysms and arterio-venous fistulas in the emergency setting. Though long term data about graft patency rates is not yet available, the endovascular approach appears to be a useful minimally invasive technique in situations where open repair is either difficult or not feasible.

  8. In humans IL-6 is released from the brain during and after exercise and paralleled by enhanced IL-6 mRNA expression in the hippocampus of mice

    DEFF Research Database (Denmark)

    Rasmussen, Per; Vedel, J-C; Olesen, J

    2011-01-01

    Aim: Plasma interleukin-6 (IL-6) increases during exercise by release from active muscles and during prolonged exercise also from the brain. The IL-6 release from muscles continues into recovery and we tested whether the brain also releases IL-6 in recovery from prolonged exercise in humans....... Additionally, it was evaluated in mice whether brain release of IL-6 reflected enhanced IL-6 mRNA expression in the brain as modulated by brain glycogen levels. Methods: Nine healthy male subjects completed 4 h of ergometer rowing while the arterio-jugular venous difference (a-v diff) for IL-6 was determined....... The IL-6 mRNA and the glycogen content were determined in mouse hippocampus, cerebellum and cortex before and after 2 h treadmill running (N = 8). Results: At rest, the IL-6 a-v diff was negligible but decreased to -2.2 ± 1.9 pg ml(-1) at the end of exercise and remained low (-2.1 ± 2.1 pg ml(-1) ) 1 h...

  9. The SafeBoosC Phase II Randomised Clinical Trial : A Treatment Guideline for Targeted Near-Infrared-Derived Cerebral Tissue Oxygenation versus Standard Treatment in Extremely Preterm Infants

    NARCIS (Netherlands)

    Pellicer, Adelina; Greisen, Gorm; Benders, Manon; Claris, Olivier; Dempsey, Eugene; Fumagalli, Monica; Gluud, Christian; Hagmann, Cornelia; Hellstroem-Westas, Lena; Hyttel-Sorensen, Simon; Lemmers, Petra; Naulaers, Gunnar; Pichler, Gerhard; Roll, Claudia; van Bel, Frank; van Oeveren, Wim; Skoog, Maria; Wolf, Martin; Austin, Topun

    2013-01-01

    Near-infrared spectroscopy-derived regional tissue oxygen saturation of haemoglobin (rSto(2)) reflects venous oxygen saturation. If cerebral metabolism is stable, rSto(2) can be used as an estimate of cerebral oxygen delivery. The SafeBoosC phase II randomised clinical trial hypothesises that the

  10. THE AZYGOS VENOUS SYSTEM AND ITS ANATOMICAL VARIATIONS

    Directory of Open Access Journals (Sweden)

    Madiki Sudhakara Rao

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES Azygos veins are important cavocaval and portacaval junctions, which form a collateral circulation in caval vein occlusion and in portal hypertension, cirrhosis of liver. The unpaired azygos venous system consists of azygos vein, hemiazygos vein and accessory azygos vein. This system of veins, along with its mediastinal, bronchial and oesophageal tributaries drains most of the body wall of trunk, namely posterior abdominal and thoracic wall. Anatomical variations of this unpaired azygos venous system are clinically important. AIMS To study and report the occurrence of anatomical variations of the unpaired azygos venous system in the region of East Godavari District, Andhra Pradesh (India. METHODS The present study was carried out in the Department of Anatomy, KIMS & RF, Amalapuram and G.S.L. Medical College, Rajahmundry over a period of 2 years. The present study was conducted on 60 cadavers (irrespective of age and sex. The entire course of the azygos venous system in these 60 cadavers was carefully observed and documented. RESULTS Anatomical variations were present in 16.66% of cases, out of which three distinct types were identified. 6.6% exhibited two separate azygos venous systems with no communications, 5% with communication between the left brachiocephalic vein and the azygos vein and 5% presence of post-aortic venous channels. CONCLUSION Variations of azygos venous system may be wrongly dubbed as aneurysm, lymphadenopathy or other abnormalities while reporting a CT scan of mediastinum. Venous anomalies are also detected only during surgery. The most troublesome intraoperative hazard is haemorrhage, which is mainly of venous origin. To avoid such situations is to have an awareness and knowledge of the expected venous anomalies.

  11. A determination of the variation in the lattice parameters of Bi2Sr2CaCu2O8+x (Bi-2212) as a function of temperature and oxygen content

    International Nuclear Information System (INIS)

    Babaei pour, M.; Ross, D.K.

    2005-01-01

    The variation of the lattice parameters of Bi-2212 has been measured using a high-temperature neutron diffraction technique. The samples have been doped with oxygen at different pressures from 2 to 400 mbar and at different temperatures from room temperature to 750 deg. C. It was found that the lattice parameters of Bi-2212 were dependent on temperature and oxygen content, increasing with temperature but decreasing with oxygen content. The values derived for the thermal expansion coefficient in an oxygen partial pressure of 400 mbar were compared with previous data from powder diffraction measurements at comparable oxygen pressure

  12. Effect of hepatic venous sphincter contraction on transmission of central venous pressure to lobar and portal pressure.

    Science.gov (United States)

    Lautt, W W; Legare, D J; Greenway, C V

    1987-11-01

    In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Oxygen isotope exchange on palladium catalysts

    International Nuclear Information System (INIS)

    Kravchuk, L.S.; Beschetvertnaya, T.I.; Novorodskij, V.G.; Novikova, M.G.; Zaretskij, M.V.; Valieva, S.V.

    1983-01-01

    Oxygen heteromolecular isotope exchange on unreduced palladium catalysts, distingushing by metal content is studied. Content of 18 O in gaseous phase is eoual to 46%. Calculations of heteroexchange rates are conducted with decrease of the 18 O in the gaseous phase over solid sample. Method of oxygen thermodesorption has been used to establish that palladium, deposited on γ-Al 2 O 3 during exchange process is in oxidized state; in this case strength of Pd-O bond is determined by content dispersity) of the metal. It is shown that significant increase of exchange rate on the samples with Pd >> 0.5 mass.% content can be induced as by side decomposition reaction of its oxide and corresponding dilution of gaseous mixture by ''light'' oxygen so by possibility of exchange with oxygen of PdO phase

  14. Normal venous anatomy and physiology of the lower extremity.

    Science.gov (United States)

    Notowitz, L B

    1993-06-01

    Venous disease of the lower extremities is common but is often misunderstood. It seems that the focus is on the exciting world of arterial anatomy and pathology, while the topic of venous anatomy and pathology comes in second place. However, venous diseases such as chronic venous insufficiency, leg ulcers, and varicose veins affect much of the population and may lead to disability and death. Nurses are often required to answer complex questions from the patients and his or her family about the patient's disease. Patients depend on nurses to provide accurate information in terms they can understand. Therefore it is important to have an understanding of the normal venous system of the legs before one can understand the complexities of venous diseases and treatments. This presents an overview of normal venous anatomy and physiology.

  15. Bilateral Pneumothoraces Following Central Venous Cannulation

    Directory of Open Access Journals (Sweden)

    F. Pazos

    2009-01-01

    Full Text Available We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax.

  16. Bilateral Pneumothoraces Following Central Venous Cannulation

    Science.gov (United States)

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax. PMID:19901997

  17. Venous injury in abusive head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Choudhary, Arabinda K. [Nemours A. I. duPont Hospital for Children, Department of Radiology, Wilmington, DE (United States); Bradford, Ray; Thamburaj, K.; Boal, Danielle K.B. [Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Dias, Mark S. [Hershey Medical Center, Department of Neurosurgery, Hershey, PA (United States)

    2015-11-15

    Abusive head trauma (AHT) is an important cause of serious brain injury in infants and young children who have characteristic clinical and imaging findings that are discordant with the clinical history provided. Recent attention has focused on abnormalities of the cranial venous sinuses and cortical veins, both on MRI and at autopsy. Although many have interpreted these to be secondary to the AHT, some have recently argued that these venous abnormalities represent primary cortical sinus and venous thrombosis that leads secondarily to subdural hemorrhage and secondary brain injury. Direct trauma to the veins and sinuses has been reported at autopsy in AHT, but there has been no systematic study of venous abnormalities in cases of AHT. The purpose of this study was to define the incidence and characteristics of venous and sinus abnormalities in AHT. We included all children <36 months of age who were diagnosed with abusive head trauma between 2001 and 2012 and who had MRI and magnetic resonance (MR) venography as part of their diagnostic workup. We analyzed age, gender and clinical findings. MRI and MR venography were analyzed independently by two neuroradiologists with a focus on abnormalities involving the intracranial veins and venous sinuses. A total of 45 children were included. The median age was 3 months (range 15 days to 31 months) and 28 were boys (62%). Clinical findings included retinal hemorrhage in 71% and extracranial fractures in 55%. CT or MRI demonstrated subdural hemorrhage in 41 (91%); none had subdural effusions. In 31 cases (69%) MR venography demonstrated mass effect on the venous sinuses or cortical draining veins, with either displacement or partial or complete effacement of the venous structures from an adjacent subdural hematoma or brain swelling. We also describe the lollipop sign, which represents direct trauma to the cortical bridging veins and was present in 20/45 (44%) children. Evidence of displacement or compression of cortical veins

  18. Venous injury in abusive head trauma

    International Nuclear Information System (INIS)

    Choudhary, Arabinda K.; Bradford, Ray; Thamburaj, K.; Boal, Danielle K.B.; Dias, Mark S.

    2015-01-01

    Abusive head trauma (AHT) is an important cause of serious brain injury in infants and young children who have characteristic clinical and imaging findings that are discordant with the clinical history provided. Recent attention has focused on abnormalities of the cranial venous sinuses and cortical veins, both on MRI and at autopsy. Although many have interpreted these to be secondary to the AHT, some have recently argued that these venous abnormalities represent primary cortical sinus and venous thrombosis that leads secondarily to subdural hemorrhage and secondary brain injury. Direct trauma to the veins and sinuses has been reported at autopsy in AHT, but there has been no systematic study of venous abnormalities in cases of AHT. The purpose of this study was to define the incidence and characteristics of venous and sinus abnormalities in AHT. We included all children <36 months of age who were diagnosed with abusive head trauma between 2001 and 2012 and who had MRI and magnetic resonance (MR) venography as part of their diagnostic workup. We analyzed age, gender and clinical findings. MRI and MR venography were analyzed independently by two neuroradiologists with a focus on abnormalities involving the intracranial veins and venous sinuses. A total of 45 children were included. The median age was 3 months (range 15 days to 31 months) and 28 were boys (62%). Clinical findings included retinal hemorrhage in 71% and extracranial fractures in 55%. CT or MRI demonstrated subdural hemorrhage in 41 (91%); none had subdural effusions. In 31 cases (69%) MR venography demonstrated mass effect on the venous sinuses or cortical draining veins, with either displacement or partial or complete effacement of the venous structures from an adjacent subdural hematoma or brain swelling. We also describe the lollipop sign, which represents direct trauma to the cortical bridging veins and was present in 20/45 (44%) children. Evidence of displacement or compression of cortical veins

  19. Erythrocytes and von Willebrand factor in venous thrombosis

    NARCIS (Netherlands)

    Smeets, M.W.J.

    2018-01-01

    Venous thromboembolism represents the third leading vascular disease after myocardial infarction and stroke. Erythrocytes, the most abundant cells in venous thrombi, were thought to be innocent bystanders that become tangled up in the fibrin mesh of venous thrombi. However, this thesis describes

  20. 'Chronic cerebrospinal venous insufficiency' in multiple sclerosis. Is multiple sclerosis a disease of the cerebrospinal venous outflow system?

    International Nuclear Information System (INIS)

    Wattjes, M.P.; Doepp, F.; Bendszus, M.; Fiehler, J.

    2011-01-01

    Chronic impaired venous outflow from the central nervous system has recently been claimed to be associated with multiple sclerosis (MS) pathology. This resulted in the term chronic cerebrospinal venous insufficiency (CCSVI) in MS. The concept of CCSVI is based on sonography studies showing that impaired venous outflow leading to pathological reflux is almost exclusively present in MS patients but not in healthy controls. Based on these findings, a new pathophysiological concept has been introduced suggesting that chronic venous outflow obstruction and venous reflux in the CNS result in pathological iron depositions leading to inflammation and neurodegeneration. The theory of CCSVI in MS has rapidly generated tremendous interest in the media and among patients and the scientific community. In particular, the potential shift in treatment concepts possibly leading to an interventional treatment approach including balloon angioplasty and venous stent placement is currently being debated. However, results from recent studies involving several imaging modalities have raised substantial concerns regarding the CCSVI concept in MS. In this review article, we explain the concept of CCSVI in MS and discuss this hypothesis in the context of MS pathophysiology and imaging studies which have tried to reproduce or refute this theory. In addition, we draw some major conclusions focusing in particular on the crucial question as to whether interventional treatment options are expedient. In conclusion, the present conclusive data confuting the theory of CCSVI in MS should lead to reluctance with respect to the interventional treatment of possible venous anomalies in MS patients. (orig.)

  1. VENOUS INSUFFICIENCY AND THROMBOEMBOLIC DISEASE IN BARIATRIC SURGERY PATIENTS

    Directory of Open Access Journals (Sweden)

    Bonno van BELLEN

    2013-09-01

    Full Text Available Context Morbid obesity is associated with various co-morbidities, including chronic venous insufficiency. Bariatric surgery is the only effective treatment for morbid obesity, but with potential risks and possible complications, including venous thromboembolism. Objective To determine the prevalence of clinical and ultrasonographic signs of chronic venous insufficiency in morbid obese patients in preparation for bariatric surgery and the incidence of post-operative venous thromboembolic disease. Methods Patients on work-up for bariatric surgery of Centro Terapêutico Especializado em Fígado (CETEFI and Pro-Gastro surgical teams of the Hospital Beneficência Portuguesa de São Paulo were included. The analysed data were pre-operative findings for venous insufficiency (CEAP - clinical, etiological, anatomical, physiopathologic - classification and venous ultrassonographic findings, type of surgery (open or laparoscopic, abdominal circumference, body mass index (BMI and post-operative ultrassonography search for venous insufficiency and deep venous thrombosis. Results Between March 2007 and December 2009, 95 patients candidates for bariatric surgery had clinical and duplex scan evaluation of the lower limbs venous system. Of the 95 patients, 53 were submitted to the surgical procedure. There was a predominance of women (77.9%, the average age was 38.5 years, average preoperative weight 124.6 kg and average BMI of 45.5 kg/m2. Regarding obesity, 16.8% were obese, and 83.1% were morbidly obese. In relation to the venous findings, 86.3% of the patients did fit CEAP classification less than 3 and 13.7% greater than or equal to 3. Among the post-operative complications, there were four cases of wound infection. Three patients developed post-operative distal venous thrombosis (7.5%, but no one had clinically manifested pulmonary embolism. Conclusion No relation between BMI, CEAP classification and venous ultrassonographic findings were found. Although

  2. [In-hospital mortality due to stroke].

    Science.gov (United States)

    Rodríguez Lucci, Federico; Pujol Lereis, Virginia; Ameriso, Sebastián; Povedano, Guillermo; Díaz, María F; Hlavnicka, Alejandro; Wainsztein, Néstor A; Ameriso, Sebastián F

    2013-01-01

    Overall mortality due to stroke has decreased in the last three decades probable due to a better control of vascular risk factors. In-hospital mortality of stroke patients has been estimated to be between 6 and 14% in most of the series reported. However, data from recent clinical trials suggest that these figures may be substantially lower. Data from FLENI Stroke Data Bank and institutional mortality records between 2000 and 2010 were reviewed. Ischemic stroke subtypes were classified according to TOAST criteria and hemorrhagic stroke subtypes were classified as intraparenchymal hematoma, aneurismatic subarachnoid hemorrhage, arterio-venous malformation, and other intraparenchymal hematomas. A total of 1514 patients were studied. Of these, 1079 (71%) were ischemic strokes,39% large vessels, 27% cardioembolic, 9% lacunar, 14% unknown etiology, and 11% others etiologies. There were 435 (29%) hemorrhagic strokes, 27% intraparenchymal hematomas, 30% aneurismatic subarachnoid hemorrhage, 25% arterio-venous malformation, and 18% other intraparenchymal hematomas. Moreover, 38 in-hospital deaths were recorded (17 ischemic strokes and 21 hemorrhagic strokes), accounting for 2.5% overall mortality (1.7% in ischemic strokes and 4.8% in hemorrhagic strokes). No deaths occurred associated with the use of intravenous fibrinolytics occurred. In our Centre in-hospital mortality in patients with stroke was low. Management of these patients in a Centre dedicated to neurological diseases along with a multidisciplinary approach from medical and non-medical staff trained in the care of cerebrovascular diseases could, at least in part, account for these results.

  3. Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, Jules, E-mail: Jules.Dyer@nhs.net [New Cross Hospital, Department of Radiology (United Kingdom); Rosa, Joao [University Hospitals Bristol NHS Foundation Trust, ST1 Radiology (United Kingdom); Chachlani, Menka [University of Birmingham (United Kingdom); Nicholas, Johann [New Cross Hospital, Department of Radiology (United Kingdom)

    2016-10-15

    PurposeThis study is the first to present the outcomes of the Straub Aspirex device for the salvage of occluded renal dialysis access fistulae.Materials and MethodsThis is a retrospective study, using data from the Renal Unit and Radiology Department database. It included all the patients between 2010 and 2014 who underwent percutaneous mechanical thrombectomy (PMT) treated by JD. Aspirex is an over-the-wire, 6–10 French catheter within which is a rapidly rotating helix which draws thrombus into a window near the tip which it then macerates and removes. Access survival was assessed using the Kaplan–Meier method, and multi-variant analysis was performed using the Cox proportional hazards model. Significance was considered if p < 0.05.ResultsA total of 27 procedures were performed for 19 patients. 13 had autologous arterio-venous fistulae, and 14 had synthetic (PTFE) arterio-venous grafts. 15 were males, 4 females. 100 % of the patients successfully had a channel of thrombus removed. This resulted in an 81.5 % initial clinical success, with primary patency rates of 53.6, 44.3 and 33 % by days 30, 90 and 480, respectively, without significant difference of any analysed covariates. No major complication (pulmonary embolus, paradoxical cerebral infarction, limb ischaemia or significant haemorrhage) occurred.ConclusionAspirex has rates of patency and complication similar to other PMT devices. No covariant studied affected outcome.

  4. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  5. Venous anomalies and abnormalities of the posterior fossa

    International Nuclear Information System (INIS)

    Goulao, A.; Alvarez, H.; Garcia Monaco, R.; Pruvost, P.; Lasjaunias, P.

    1990-01-01

    The authors report a series of 16 patients with venous anomalies or abnormalities of the posterior fossa studied by angiography, CT and/or MRI. We believe that so-called 'venous angioma' are extreme anatomic variants that drain normal territories, and we prefer to call them developmental venous anomalies (DVA). Posterior fossa DVA, like the supra-tentorial ones are classified according to their drainage into deep and superficial type. They are exclusively located in the cerebellum or tectum. In 4 cases DVA was an incidental finding, in 3 an associated cerebral venous malformation (CVM) was found and felt to be the cause of the symptoms and only in one (Trigeminal pain) was a link between both suspected. Cavernous venous malformation (CVM) were found in frequent association with DVA (27%). 4 cases were single and 2 multiple. 5 CVM were located in the brain stem and 3 in the cerebellum. The clinical and radiological files were reviewed and a direct relationship between symptoms and localization was found in all patients with CVM. In 2 cases venous dysplasia was found: 1 Sturge-Weber and 1 First branchial arch syndrome. Both posterior fossa venous abnormalities were incidental findings. (orig.)

  6. Hepatic venous pressure gradients measured by duplex ultrasound

    International Nuclear Information System (INIS)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M.

    2002-01-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P -2 provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  7. Carbon dioxide hepatic arterial DSA and CT angiography in swine model

    International Nuclear Information System (INIS)

    Tan Huaqiao; Hu Hongjie; Huang Wenxin; Zhang Shizheng; Dong Yonghua; Zhou Dachun

    2005-01-01

    Objective: To evaluate the imaging findings of carbon dioxide hepatic arterial DSA and CT angiography in normal swine. Methods: In general anaesthesia, hepatic arterial DSA was performed with 10 ml iodinated contrast medium (5 ml/s, 10 ml) in 5 normal swine, and then repeated hepatic arterial CO 2 -DSA was performed with a total of 30-50 ml CO 2 injected by manually operated syringe at the velocity of 5-8 ml/s, followed by CO 2 -CT angiography. All the swine were sacrificed after the procedure, the selective hepatic segments were removed, and pathological examination was carried out. The radiological features of hepatic arterial DSA with iodinated contrast medium and CO 2 and CT angiography with CO 2 were analyzed. The ability of showing the arterio-venous shunt was compared. Results: Hepatic arterio-portal shunt was found in the advanced arterial phase of CO 2 -DSA in three of five swine, which was furthermore demonstrated by CO 2 -CT angiography, but iodinated contrast medium DSA showed no arterio-portal shunt in all swine. The gaseous CO 2 in portal vein was absorbed within 1-3 minutes. No CO 2 shunted into the hepatic vein during CO 2 -DSA and CO 2 -CTA. Histology didn't reveal any abnormal changes caused by CO 2 shunt in the swine liver. Conclusion: (1) Hepatic arterial CO 2 -DSA and CO 2 -CTA can reveal arterio-portal shunt that isn't seen with iodinated contrast medium, the gaseous CO 2 in portal vein was absorbed within 1-3 minutes. (2) The gaseous CO 2 can't shunt into hepatic vein when the hepatic artery is perfused with CO 2 in normal swine. (authors)

  8. Quantification of modulated blood oxygenation levels in single cerebral veins by investigating their MR signal decay

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacik, Jan [St. Jude Children' s Research Hospital, Memphis, TN (United States). Div. of Translational Imaging Research; University Clinics Jena (Germany). Medical Physics Group; Rauscher, Alexander [University Clinics Jena (Germany). Medical Physics Group; British Columbia Univ., Vancouver (Canada). MRI Research Centre; Reichenbach, Juergen R. [University Clinics Jena (Germany). Medical Physics Group

    2009-07-01

    The transverse magnetization of a single vein and its surrounding tissue is subject to spin dephasing caused by the local magnetic field inhomogeneity which is induced by the very same vessel. This phenomenon can be approximated and simulated by applying the model of an infinitely long and homogeneously magnetized cylinder embedded in a homogeneous tissue background. It is then possible to estimate the oxygenation level of the venous blood by fitting the simulated magnetization-time-course to the measured signal decay. In this work we demonstrate the ability of this approach to quantify the blood oxygenation level (Y) of small cerebral veins in vivo, not only under normal physiologic conditions (Y{sub native}=0.5-0.55) but also during induced changes of physiologic conditions which affect the cerebral venous blood oxygenation level. Changes of blood's oxygenation level induced by carbogen (5% CO{sub 2}, 95% O{sub 2}) and caffeine were observed and quantified, resulting in values of Y{sub carbogen}=0.7 and Y{sub caffeine}=0.42, respectively. The proposed technique may ultimately help to better understand local changes in cerebral physiology during neuronal activation by quantifying blood oxygenation in veins draining active brain areas. It may also be beneficial in clinical applications where it may improve diagnosis of cerebral pathologies as well as monitoring of responses to therapy. (orig.)

  9. Veno-venous extracorporeal membrane oxygenation using an innovative dual-lumen cannula following implantation of a total artificial heart.

    Science.gov (United States)

    Youdle, Jemma; Penn, Sarah; Maunz, Olaf; Simon, Andre

    2017-01-01

    We report our first clinical use of the new Protek Duo TM cannula for peripheral veno-venous extra-corporeal life support (ECLS). A 53-year-old male patient underwent implantation of a total artificial heart (TAH) for biventricular failure. However, due to the development of post-operative respiratory dysfunction, the patient required ECLS for six days.

  10. Pulmonary venous abnormalities encountered on pre ...

    African Journals Online (AJOL)

    Multidetector computed tomography (MDCT) elegantly renders pulmonary venous anatomy. With increasing numbers of radiofrequency ablation procedures being performed, there is now a greater emphasis on pre-procedure imaging to delineate this anatomy. Pulmonary venous mapping studies can be performed with or ...

  11. Structure and charge transfer correlated with oxygen content for a Y0.8Ca0.2Ba2Cu3Oy (y = 6.84 6.32) system: a positron study

    Science.gov (United States)

    Cao, Shixun; Li, Lingwei; Liu, Fen; Li, Wenfeng; Chi, Changyun; Jing, Chao; Zhang, Jincang

    2005-05-01

    The structure and charge transfer correlated with oxygen content are studied by measuring the positron lifetime parameters of the Y0.8Ca0.2Ba2Cu3Oy system with a large range of oxygen content (y = 6.84-6.32). The local electron density ne is evaluated from the positron lifetime data. The positron lifetime parameters show a clear change around y = 6.50 where the compounds undergo the orthorhombic-tetragonal phase transition. The effect of ne and oxygen content on the structure, charge transfer and superconductivity are discussed. With the decrease of oxygen content y, O(4) tends to the Cu(1) site, causing carrier localization, and accordingly, the decrease of ne. This would prove that the localized carriers (electrons and holes) in the Cu-O chain region have great influence on the superconductivity by affecting the charge transfer between the reservoir layers and the conducting layers. The positron annihilation mechanism and its relation with superconductivity are also discussed.

  12. ENDOVASCULAR TREATMENT FOR DISORDERS OF THE VENOUS SYSTEM

    Directory of Open Access Journals (Sweden)

    A. G. Osiev

    2015-01-01

    Full Text Available The annual rate of deep vein thrombosis in general population is from 5 to 9 cases per 10 000, whereas for venous thromboembolism (deep vein thrombosis and pulmonary embolism taken together amounts to 14 cases per 10 000. To improve longterm results of therapy for thrombosis of deep veins of the lower extremities, it is important to restore venous function and outflow. Anticoagulant therapy with low weight or non-fractionated heparin preparations remains the most widely used method of management. However, total or partial thrombosis resolution under anticoagulant treatment is achieved only in 4 and 14% of cases, respectively. Thrombolysis allows for early resorption of the thrombus by means of a minimally invasive procedure with lower risk of complication. After the venous flow is restored, the aim of treatment is to prevent damage to the venous valves, venous hypertension and repeated thrombosis with development of the post-thrombotic syndrome. Compared to anticoagulation, systemic thrombolysis has the benefit of more rapid clot resorption and less damage to the venous valve. One of its serious limitations is a high bleeding risk related to higher doses of the drug administered through a peripheral vein catheter. Therefore, selective intra-clot administration of thombolytics (direct catheter thrombolysis has been suggested as an alternative. For more effective therapy with the use of lower doses of thrombolytics, the so called pharmaco-mechanical thrombectomy has been developed. Venous stenosis hindering the venous outflow is frequently seen after direct catheter or pharmaco-mechanical thrombolysis. Angioplasty with stent placement is recommended in the cases with residual venous abnormality after successful thrombolysis and thrombectomy. 

  13. Relationship between biochemical factors and skin symptoms in chronic venous disease.

    Science.gov (United States)

    Takai, Yasushi; Hiramoto, Keiichi; Nishimura, Yoshiyuki; Ooi, Kazuya

    2017-05-01

    Chronic venous disease (CVD) is a common venous disease of the lower extremities and patients often develop symptoms of itching and skin roughness. An easy to use and objective skin examination was recently developed that allows measurement of the level of stratum corneum content and transepidermal water loss (TEWL), which can indicate the status of the barrier function of the stratum corneum. Previous studies demonstrated that histamine production from mast cells, and tryptase and matrix metalloprotease-9 levels were associated with skin inflammation. This study aimed to clarify the relationship between dry skin and inflammatory mediators that mediate the skin symptoms of CVD subjects. The study enrolled 27 subjects with CVD and a control group consisting of 9 volunteers. The itching onset frequency was higher in women (70.4%) compared with men (50.0%). To analyze the mechanisms involved in itching we measured blood inflammatory mediators pre- and post-sclerotherapy. There was a significant decrease in Substance P, histamine, IgE, and tryptase levels post-sclerotherapy compared with those at pre-sclerotherapy. These levels were associated with the severity of itching. In addition, compared with the control subjects, there was a significant increase in the stratum corneum water content and a decrease in the TEWL in the 27 patients with CVD. This was associated with a decrease in the itching symptoms. Our findings indicate that sclerotherapy decreased levels of inflammatory mediators, increased stratum corneum water content and decreased TEWL, which coincided with reduced itching in CVD patients, indicating they might be therapeutic targets.

  14. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M. [University of Arkansas for Medical Sciences, Pediatric Radiology, Little Rock, AR (United States)

    2016-01-15

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  15. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    International Nuclear Information System (INIS)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M.

    2016-01-01

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  16. MR findings of cerebral venous sinus thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Myung Kwan; Chang, Kee Hyun; Han, Moon Hee; Choi, Choong Gom [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To describe MR findings of cerebral venous sinus thrombosis. We reviewed 11 MR images of six patients with cerebral venous sinus thrombosis. The MR images were retrospectively analyzed in terms of location and signal intensity of the thrombi, parenchymal lesions such as hemorrhage and edema, and changes in follow up study obtained in 4 patients. The thrombus in venous sinus was visualized on MRI in all six patients. The most frequently involved sites were superior sagittal sinus(n=4) and left transverse sinus(n=4). Signal intensity of the thrombus was isointense or hyperintense on both T1- and T2-weighted images with loss of normal signal void of the sinus on all sequences in all patients. Parenchymal lesion was patients in five of six cases, manifested as local hemorrhage in three and edema in three cases(one case overlapped). Local edema seen in three patients was completely resolved on follow up study of seven to 29 days intervals. It is concluded that iso- or high signal intensity with loss of signal void in venous sinus is virtually diagnostic of venous sinus thrombosis. If there are local parenchymal lesions such as hemorrhage and/or edema of unknown causes, cerebral venous sinus thrombosis should be included in differential diagnosis.

  17. A theoretical model for oxygen transport in skeletal muscle under conditions of high oxygen demand.

    Science.gov (United States)

    McGuire, B J; Secomb, T W

    2001-11-01

    Oxygen transport from capillaries to exercising skeletal muscle is studied by use of a Krogh-type cylinder model. The goal is to predict oxygen consumption under conditions of high demand, on the basis of a consideration of transport processes occurring at the microvascular level. Effects of the decline in oxygen content of blood flowing along capillaries, intravascular resistance to oxygen diffusion, and myoglobin-facilitated diffusion are included. Parameter values are based on human skeletal muscle. The dependence of oxygen consumption on oxygen demand, perfusion, and capillary density are examined. When demand is moderate, the tissue is well oxygenated and consumption is slightly less than demand. When demand is high, capillary oxygen content declines rapidly with axial distance and radial oxygen transport is limited by diffusion resistance within the capillary and the tissue. Under these conditions, much of the tissue is hypoxic, consumption is substantially less than demand, and consumption is strongly dependent on capillary density. Predicted consumption rates are comparable with experimentally observed maximal rates of oxygen consumption.

  18. History of venous leg ulcers.

    Science.gov (United States)

    Gianfaldoni, S; Wollina, U; Lotti, J; Gianfaldoni, R; Lotti, T; Fioranelli, M; Roccia, M G

    To retrieve the history of venous ulcers and of skin lesions in general, we must go back to the appearance of human beings on earth. It is interesting to note that cutaneous injuries evolved parallel to human society. An essential first step in the pathogenesis of ulcers was represented by the transition of the quadruped man to Homo Erectus. This condition was characterized by a greater gravitational pressure on the lower limbs, with consequences on the peripheral venous system. Furthermore, human evolution was characterized by an increased risk of traumatic injuries, secondary to his natural need to create fire and hunt (e.g. stones, iron, fire, animal fighting). Humans then began to fight one another until they came to real wars, with increased frequency of wounds and infectious complications. The situation degraded with the introduction of horse riding, introduced by the Scites, who first tamed animals in the 7th century BC. This condition exhibited iliac veins at compression phenomena, favouring the venous stasis. With time, man continued to evolve until the modern age, which is characterized by increased risk factors for venous wounds such as poor physical activity and dietary errors (1, 2).

  19. Lactate uptake against a concentration gradient

    DEFF Research Database (Denmark)

    Nordström, Carl-Henrik; Nielsen, Troels Halfeld; Nielsen, Hans Boye

    2014-01-01

    The recently published article by Jalloh et al (Jalloh I, Helmy A, Shannon RJ, Gallagher CN, Menon D, Carpenter K, Hutchinson P. Lactate uptake by the injured human brain - evidence from an arterio-venous gradient and cerebral microdialysis study. J Neurotrauma. 2013 Aug 22. [Epub ahead of print......]) concludes that lactate may be transported across the blood brain barrier into the brain against a concentration gradient. Unfortunately the authors have misinterpreted the concept of analytical imprecision and their conclusion is based on analytical artifact. As the topic of lactate transport into the brain...

  20. NOTE: Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion

    Science.gov (United States)

    van Gemert, Martin J. C.; van den Wijngaard, Jeroen P. H. M.; Lopriore, Enrico; Pasman, Suzanne A.; Vandenbussche, Frank P. H. A.

    2008-04-01

    Twin-twin transfusion syndrome (TTTS) is a severe complication of monozygotic (identical) twin fetuses sharing one single (monochorionic) placenta. TTTS is caused by a net inter-twin transfusion of blood through placental anastomoses, from one twin (the donor) to the other (the recipient), which link the two feto-placental circulations. Currently, the only reliable method to measure the net inter-twin transfusion clinically is when incomplete laser therapy of TTTS occurs and one of the twins becomes anemic and requires an intra-uterine transfusion of adult red blood cells. Then, differences between adult hemoglobin concentrations measured during the transfusion and at birth relate not only to the net inter-twin transfusion but also to the finite lifetime of the adult red blood cells. We have analyzed this situation, derived the differential equations of adult hemoglobin in the donor and recipient twins, given the solutions and given expressions relating the net inter-twin flow with clinically measured parameters. We have included single and multiple intra-uterine transfusions. In conclusion, because incomplete laser therapy occurs frequently, and some cases require an intra-uterine transfusion, this method may allow collecting a wealth of net inter-twin flow data from clinicians involved in laser therapy of TTTS. To aid to the widespread use of this method, we have presented the equations as clearly as possible in tables for easy use by others.

  1. Vitreous hemorrhage as a clue to late presenting Pulmonary Arterio Venous Malformation

    Directory of Open Access Journals (Sweden)

    Brijesh Takkar

    2017-10-01

    Full Text Available Retinal vasculature is frequently altered in systemic vascular disorders such as Diabetes and Hypertension. We present a rare case in which vitreous hemorrhage was the presenting sign of an underlying congenital cyanotic heart disease. Keywords: Vitreous hemorrhage, Cyanotic heart disease, Conjunctival telangiectasia

  2. Computed tomographic manifestations of abdominal and pelvic venous collaterals

    International Nuclear Information System (INIS)

    Pagani, J.J.; Thomas, J.L.; Bernardino, M.E.

    1982-01-01

    Obstruction of blood flow through the inferior vena cava and portal vein may produce venous collaterals. These include the paravertebral venous system and its communications with the ascending lumbar veins and azygous/hemiazygous system; gonadal, periureteric, and other retroperitoneal veins; abdominal wall veins; hemorrhoidal venous plexus; and the portal venous system. The anatomic location of these vessels is discussed. Computed tomography demonstrates them as round or tubular structures that are isodens when compared with other venous structures following contrast material administration. Techniques of examination and methods of differentiation of these vascular structures from other abnormalities, especially lymphadenopathy, are discussed

  3. Improvements in or relating to processes for reducing the oxygen content of metal oxides

    International Nuclear Information System (INIS)

    James, R.H.; Spooner, J.A.

    1980-01-01

    A process is described for reducing the oxygen content of a metal oxide material (such as an intimate mixture of uranium and plutonium oxides or a mixed oxide of uranium and plutonium) by contacting the material with a hydrogen-containing gas at an elevated temperature, wherein the material is contained in a plurality of carbon crucibles, each crucible having apertured ends and being otherwise a closed vessel, the crucibles being moved through a heated zone in end-to-end contact and thereby forming a duct through which the gas is passed counter-current to the direction of movement of the crucibles. (author)

  4. Sex-specific aspects of venous thrombosis

    NARCIS (Netherlands)

    Roach, Rachel Elizabeth Jo

    2014-01-01

    Venous thrombosis is a disease that occurs in 1-2 per 1000 people per year. At the time of their first venous thrombosis, approximately 50% of women are exposed to reproductive risk factors (oral contraception, postmenopausal hormone therapy, pregnancy and the puerperium). In this thesis, we showed

  5. [Venous thrombosis associated with central venous catheter use in patients with cancer].

    Science.gov (United States)

    Iglesias Rey, Leticia; Fernández Pérez, Isaura; Barbagelata López, Cristina; Rivera Gallego, Alberto

    2015-01-01

    The use of central venous catheters for various applications (administration of chemotherapy, blood products and others) in patients with cancer is increasingly frequent. The association between thrombosis and catheter use has been fully established but aspects such as its causes, diagnosis, prophylaxis and treatment have not. We describe a case of thrombosis in a patient with cancer treated with chemotherapy who carried a central venous catheter. We also perform a review of the risk factors, the role of the prophylaxis and the treatment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  6. Intracranial developmental venous anomaly: is it asymptomatic?

    Science.gov (United States)

    Puente, A Bolívar; de Asís Bravo Rodríguez, F; Bravo Rey, I; Romero, E Roldán

    2018-03-16

    Intracranial developmental venous anomalies are the most common vascular malformation. In the immense majority of cases, these anomalies are asymptomatic and discovered incidentally, and they are considered benign. Very exceptionally, however, they can cause neurological symptoms. In this article, we present three cases of patients with developmental venous anomalies that presented with different symptoms owing to complications derived from altered venous drainage. These anomalies were located in the left insula, right temporal lobe, and cerebellum. The exceptionality of the cases presented as well as of the images associated, which show the mechanism through which the symptoms developed, lies in the low incidence of symptomatic developmental venous anomalies reported in the literature. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Venous sinus stenting for pseudotumour cerebri with venous sinus stenosis

    International Nuclear Information System (INIS)

    Chen Huairui; Bai Rulin; Wu Xiaojun; Qi Xiangqian; Mei Qiyong; Lu Yicheng

    2011-01-01

    Objective: To explore the relation between venous sinus stenosis and pseduotumour cerebri and to discuss the efficacy and strategy of venous sinus stenting for its treatment. Methods: Venous sinus stenting was performed in a total of 9 patients with pseudotumour cerebri accompanied by dural sinus stenosis. The clinical data, including the clinical presentations, intracranial pressure, angiographic findings, pressure of dural sinus,methods of treatment and the therapeutic results, were retrospectively analyzed. Results: Bilateral disc edema was seen in all patients. The pressure gradient in the lateral sinuses was obviously high before stenting (22.67±7.25)mmHg in all patients and a reduction in intra-sinus pressure and pressure gradient was also found (5.78±3.77)mmHg. The symptoms associated with intracranial hypertension were gradually improved or disappeared in two weeks after the placement of the stent in all cases, and the intracranial pressure dropped evidently (12.78±5.97)cm H 2 O. Vision was improved in 7 cases at three months, whereas it remained poor in 2 cases despite normalized intracranial pressure. There was no other permanent procedure-related morbidity. The patients were followed up for 3 months to 5 years, and no recurrence developed. Conclusion: Lateral sinus stenting is an effective method for the treatment of pseudotumour cerebri with dural sinus stenosis. (authors)

  8. Effects of isokinetic calf muscle exercise program on muscle strength and venous function in patients with chronic venous insufficiency.

    Science.gov (United States)

    Ercan, Sabriye; Çetin, Cem; Yavuz, Turhan; Demir, Hilmi M; Atalay, Yurdagül B

    2018-05-01

    Objective The aim of this study was to observe the change of the ankle joint range of motion, the muscle strength values measured with an isokinetic dynamometer, pain scores, quality of life scale, and venous return time in chronic venous insufficiency diagnosed patients by prospective follow-up after 12-week exercise program including isokinetic exercises. Methods The patient group of this study comprised 27 patients (23 female, 4 male) who were diagnosed with chronic venous insufficiency. An exercise program including isokinetic exercise for the calf muscle was given to patients three days per week for 12 weeks. At the end of 12 weeks, five of the patients left the study due to inadequate compliance with the exercise program. As a result, control data of 22 patients were included. Ankle joint range of active motion, isokinetic muscle strength, pain, quality of life, and photoplethysmography measurements were assessed before starting and after the exercise program. Results Evaluating changes of the starting and control data depending on time showed that all isokinetic muscle strength measurement parameters, range of motion, and overall quality of life values of patients improved. Venous return time values have also increased significantly ( p < 0.05). Conclusion In conclusion, increase in muscle strength has been provided with exercise therapy in patients with chronic venous insufficiency. It has been determined that the increase in muscle strength affected the venous pump and this ensured improvement in venous function and range of motion of the ankle. In addition, it has been detected that pain reduced and quality of life improved after the exercise program.

  9. Inflammation and peripheral venous disease. The San Diego Population Study.

    Science.gov (United States)

    Cushman, M; Callas, P W; Allison, M A; Criqui, M H

    2014-09-02

    The inflammatory response to healing in venous thrombosis might cause vein damage and post-thrombotic syndrome. Inflammation may also be involved in venous insufficiency apart from deep-vein thrombosis. We studied the association of inflammation markers with venous insufficiency in a general population sample. We characterised 2,404 men and women in a general population cohort for peripheral venous disease and its severity using physical exam, symptom assessment, and venous ultrasound. Inflammation markers, C-reactive protein (CRP), fibrinogen, interleukin 1-beta (IL-1-beta), IL-8, IL-10, intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), E-selectin, monocyte chemoattractant-1 (MCP-1) and vascular endothelial cell growth factor (VEGF) were compared in 352 case participants with peripheral venous disease and 352 controls with no venous abnormalities frequency matched to cases by age, sex and race. Associations were also evaluated including a subset of 108 cases of severe venous disease, as previously defined. Odds ratios (95% CI), for peripheral venous disease for biomarkers in the top quartile (adjusting for age, race, sex, body mass index and history of venous thrombosis) were 1.8 (1.1-3.0), 1.6 (1.0-2.5) and 1.5 (0.9-2.3) for CRP, fibrinogen and IL-10, respectively. Associations were larger considering cases of severe venous disease, with odds ratios for these three analytes of 2.6 (1.2-5.9), 3.1 (1.3-7.3) and 2.2 (1.1-4.4), and for IL-8: 2.4 (1.1-5.2). There was no association of IL-1-beta, ICAM-1, VCAM-1, E-selectin, MCP-1 or VEGF with overall cases or severe venous disease. In conclusion, a subset of inflammation markers were associated with increased risk of peripheral venous disease, suggesting potential therapeutic targets for treatment.

  10. Clinicoroentgenological diagnosis of chronic venous ovarian insufficiency

    International Nuclear Information System (INIS)

    Grakova, L.S.; Galkin, E.V.; Naumova, E.B.

    1989-01-01

    The paper is devoted to clinicoroentgenological correlations of venous renogonadal hemodynamics in 168 women of reproductive age (151 women with infertility, habitual abortion, disordered menstrual function and 17 patients without disorders of the reproductive tract). Clinicolaboratory investigation was followed by visceral and parietal flebography for the detection of a pathological venous reflux into the ovarian pampiniform plexus. Clinicoroentgenological semiotics of chronic venous ovarian insufficiency was analyzed. Infertility was shown to be the main clinical manifestation of ovarian varicocele

  11. REVIEW ARTICLE Venous thromboembolism associated with ...

    Indian Academy of Sciences (India)

    Navya

    2017-03-24

    Mar 24, 2017 ... Venous thromboembolism associated with protein S deficiency due to ... 2 Institute of Cardiology, Jagiellonian University Medical College, Kraków, Poland ... It has been long recognized that reduced PS activity is a risk factor for venous ... 1988). Sequencing of PROS1 gene intensified studies of genotype-.

  12. Portal-venous gas unrelated to mesenteric ischemia

    International Nuclear Information System (INIS)

    Wiesner, Walter; Mortele, Koenraad J.; Ji, Hoon; Ros, Pablo R.; Glickman, Jonathan N.

    2002-01-01

    The aim of this study was to report on 8 patients with all different non-ischemic etiologies for portal-venous gas and to discuss this rare entity and its potentially misleading CT findings in context with a review of the literature. The CT examinations of eight patients who presented with intrahepatic portal-venous gas, unrelated to bowel ischemia or infarction, were reviewed and compared with their medical records with special emphasis on the pathogenesis and clinical impact of portal-venous gas caused by non-ischemic conditions. The etiologies for portal-venous gas included: abdominal trauma (n=1); large gastric cancer (n=1); prior gastroscopic biopsy (n=1); prior hemicolectomy (n=1); graft-vs-host reaction (n=1); large paracolic abscess (n=1); mesenteric recurrence of ovarian cancer superinfected with clostridium septicum (n=1); and sepsis with Pseudomonas aeruginosa (n=1). The clinical outcome of all patients was determined by their underlying disease and not negatively influenced by the presence of portal-venous gas. Although the presence of portal-venous gas usually raises the suspicion of bowel ischemia and/or intestinal necrosis, this CT finding may be related to a variety of non-ischemic etiologies and pathogeneses as well. The knowledge about these conditions may help to avoid misinterpretation of CT findings, inappropriate clinical uncertainty and unnecessary surgery in certain cases. (orig.)

  13. Postoperative deep venous thrombosis in Japan. Incidence and prophylaxis

    International Nuclear Information System (INIS)

    Inada, K.; Shirai, N.; Hayashi, M.; Matsumoto, K.; Hirose, M.

    1983-01-01

    The incidence of postoperative deep venous thrombosis was investigated using the iodine-125-fibrinogen method in 256 patients undergoing major surgery. Deep venous thrombosis was found in 49 patients (15.3 percent), and nonfatal pulmonary embolism developed in one of seven patients in whom the thrombus extended to the popliteal vein. The same investigation was performed in 110 patients who wore a graduated compression stocking on one leg, with the other leg serving as a control. Deep venous thrombosis was found in 4 of 110 stockinged legs (3.6 percent) and in 16 of 110 control legs (14.5 percent). The incidence of deep venous thrombosis decreased significantly in patients who wore the stocking. An increase in femoral venous flow velocity was found in the stockinged legs by the Doppler method. The mean velocity of venous return by xenon-133 clearance was significantly greater in the stockinged legs than in the control legs. These findings were considered to support the efficacy of graduated compression stockings for the prevention of deep venous thrombosis

  14. Evidence of oxygen content heterogeneity in TSMTG YBa{sub 2}Cu{sub 3}O{sub 7-{delta}}/Y{sub 2}BaCuO{sub 5} composites by micro-Raman spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Delorme, F. [Laboratoire CRISMAT, UMR CNRS 6508, ISMRA, Boulevard du Marechal Juin, 14050 Caen Cedex (France)], E-mail: f.delorme@brgm.fr; Bardeau, J.-F. [Laboratoire de Physique de l' Etat Condense, Faculte des Sciences, Universite du Maine, Avenue Olivier Messiaen, 72085 Le Mans Cedex 09 (France); Harnois, C. [Laboratoire CRISMAT, UMR CNRS 6508, ISMRA, Boulevard du Marechal Juin, 14050 Caen Cedex (France); Monot-Laffez, I. [Laboratoire LEMA, CNRS FRE-2077- CEA-LRC M01 - IUT de Blois, 3 Place Jean Jaures, CS2903, 41029 Blois (France)

    2008-03-01

    The homogeneity of the oxygen content of TSMTG-YBa{sub 2}Cu{sub 3}O{sub 7-{delta}}/Y{sub 2}BaCuO{sub 5} composites has been investigated by micro-Raman spectrometry. The Y123 compound has been found to be very sensitive to the laser power, but a laser power of 0.04 mW has been shown to not to be harmful for the samples, even after 2 h of irradiation. Raman spectra have shown that the oxygen content of YBa{sub 2}Cu{sub 3}O{sub 7-{delta}}/Y{sub 2}BaCuO{sub 5} ceramics is not homogeneous at the micrometer scale. In addition, no monotonic decrease of the oxygen content is observed from the periphery to the core of the sample, confirming that the oxygen uptake is not strictly controlled by a diffusion process.

  15. Congenital Retinal Macrovessel and the Association of Retinal Venous Malformations With Venous Malformations of the Brain.

    Science.gov (United States)

    Pichi, Francesco; Freund, K Bailey; Ciardella, Antonio; Morara, Mariachiara; Abboud, Emad B; Ghazi, Nicola; Dackiw, Christine; Choudhry, Netan; Souza, Eduardo Cunha; Cunha, Leonardo Provetti; Arevalo, J Fernando; Liu, T Y Alvin; Wenick, Adam; He, Lingmin; Villarreal, Guadalupe; Neri, Piergiorgio; Sarraf, David

    2018-04-01

    Congenital retinal macrovessel (CRM) is a rarely reported venous malformation of the retina that is associated with venous anomalies of the brain. To study the multimodal imaging findings of a series of eyes with congenital retinal macrovessel and describe the systemic associations. In this cross-sectional multicenter study, medical records were retrospectively reviewed from 7 different retina clinics worldwide over a 10-year period (2007-2017). Patients with CRM, defined as an abnormal, large, macular vessel with a vascular distribution above and below the horizontal raphe, were identified. Data were analyzed from December 2016 to August 2017. Clinical information and multimodal retinal imaging findings were collected and studied. Pertinent systemic information, including brain magnetic resonance imaging findings, was also noted if available. Of the 49 included patients, 32 (65%) were female, and the mean (SD) age at onset was 44.0 (20.9) years. A total of 49 eyes from 49 patients were studied. Macrovessel was unilateral in all patients. Color fundus photography illustrated a large aberrant dilated and tortuous retinal vein in all patients. Early-phase frames of fluorescein angiography further confirmed the venous nature of the macrovessel in 40 of 40 eyes. Optical coherence tomography angiography, available in 17 eyes (35%), displayed microvascular capillary abnormalities around the CRM, which were more evident in the deep capillary plexus. Of the 49 patients with CRM, 39 (80%) did not illustrate any evidence of ophthalmic complications. Ten patients (20%) presented with retinal complications, typically an incidental association with CRM. Twelve patients (24%) were noted to have venous malformations of the brain with associated magnetic resonance imaging. Of these, location of the venous anomaly in the brain was ipsilateral to the CRM in 10 patients (83%) and contralateral in 2 patients (17%), mainly located in the frontal lobe in 9 patients (75%). Our study has

  16. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain

    International Nuclear Information System (INIS)

    Sedlacik, Jan; Fiehler, Jens; Reitz, Matthias; Schmidt, Nils O.; Bolar, Divya S.; Adalsteinsson, Elfar

    2015-01-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml.kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s and -1] = 20.7/20.4/20.1, R2*[s and -1] = 31.6/29.6/25.9, R2'[s and 1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml.min and -1.100g and -1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood oxygenation level. We found good

  17. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacik, Jan; Fiehler, Jens [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Neuroradiology; Reitz, Matthias; Schmidt, Nils O. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Neurosurgery; Bolar, Divya S. [Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States). Radiology; Adalsteinsson, Elfar [Massachusetts Institute of Technology, Cambridge, MA (United States). Electrical Engineering and Computer Science

    2015-05-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml.kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s {sup and} -1] = 20.7/20.4/20.1, R2*[s {sup and} -1] = 31.6/29.6/25.9, R2'[s {sup and} 1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml.min {sup and} -1.100g {sup and} -1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood

  18. 2,3-diphosphoglycerate and oxygen supply of tissues in cardiosurgical diabetics.

    Science.gov (United States)

    Beder, I; Mataseje, A; Kittova, M; Carsky, J; Fischer, V

    2005-01-01

    The oxygen supply of tissues was studied under haemodilution in cardiosurgical diabetic and non-diabetic patients. There were 30 cardiosurgery patients examined, 9 were patients with diabetes mellitus.and 21 were non-diabetic patients. Venous blood samples were examined preoperatively, intraoperatively and for 10 days after operation. Haemodilution caused a decrease in haematocrit values in both groups, as well as in the erythrocyte count and haemoglobin concentration. Postoperatively, an increase was recorded in haematological values in both groups, the values had not reached the baseline even by 10th day. Increased values of blood oxygen saturation and partial oxygen pressure during the operation returned to baseline in both groups in the postoperative days. Values of p50 did not change in both groups for the period of observation. The obtained data suggest that sufficient oxygen supply to tissues was ensured under haemodilution in cardiosurgery patients in both groups. These results confirm multifactorial dependence of blood oxygen transport to tissues (Tab. 1, Fig. 3, Ref. 13).

  19. Hepatic venous pressure gradients measured by duplex ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M

    2002-08-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P < 0.0001) and with the Child-Pugh score (r = 0.63, P < 0.0001). An acceleration index cut-off value of 1 m.s{sup -2} provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  20. Carbon dioxide as a venous contrast agent: Applications in interventional radiology=20

    International Nuclear Information System (INIS)

    Hahn, Seong Tae; Lee, Jae Mun; Kim, Choon Yul; Shinn, Kyung Sub; Pfammatter, Thomas; Cho, Kyung Jae

    1997-01-01

    To evaluate the safety and usefulness of carbon dioxide(CO 2 ) as a venous contrast agent for upper-arm placement of peripherally inserted central venous catheter (PICC), vena caval filter placement, and for visualization of the portal vein in transjugular intrahepatic portosystemic shunt(TIPS). About 20-30ml of CO 2 was used as an alternative to iodinated contrast material for digital subtraction angiography (DSA) and fluoroscopy to guide upper-arm placement of PICC in 46 patients, for inferior venacavogram before filter placement in five, and for visualization of the portal vein during TIPS in two. Vital signs, peripheral arterial oxygen saturation, and renal function were checked during and after delivery of CO 2 . All CO 2 DSA for PICC placement clearly delineated patency or stenosis of the central veins. In 41 of 46 patients (89 %), PICC placement with CO 2 guidance was successful. The mean number of venipunctures for PICC placement was 1.9, and the mean volume of CO 2 injected for venipuncture was 35ml. In five patients, Titanium Greenfield filters were successfully implanted into the inferior vena cava following CO 2 vena cavography. In two patients in whom hepatopetal portal flow was seen on indirect portography, the portal vein was visualized by CO 2 -wedged hepatic venography. Injection of CO 2 into the splenic vein following TIPS placement revealed shunt patency. Vital signs and oxygen saturation did not change, and there was no evidence of renal toxicity following CO 2 injection. CO 2 is a safe and useful alternative contrast agent for upper-arm placement of PICC, pre-filter placement cavography, and wedged hepatic venography and portography for TIPS

  1. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  2. Diagnostics of defeats of venous collectors of brain

    International Nuclear Information System (INIS)

    Timofeeva, T.V.; Polunina, I.S.; Shcherbakova, E.Ya.; Kuldakova, S.V.

    1997-01-01

    Comparative data of transcranial ultrasonic dopplerography (170 patients) and radionuclidous antroscintigraphy (124), received during diagnostics of defects of venous collectors of brain are analyzed. Five variants of defeats of venous collectors (cross, sigmoid, internal of jugular of jugular vein), but also unpaired sine (direct, confluent) are described. Received results permit to reveal interrelation of infringements of venous outflow and increase of intracranial pressure

  3. Congenital absence of infrarenal IVC and iliac venous system : Unusual collateral Pathways

    International Nuclear Information System (INIS)

    Lee, Jin Joo; Lee, Byung Hee; Kim, Kie Hwan; Do, Young Soo; Chin, Soo Yil

    1994-01-01

    We present a case with congenital absence of the infrarenal portion of inferior vena cava and iliac venous system, showing unusual venous collaterals including the left ovarian venous collateral via parametrial venous complex, and a mesenteric-periureteric venous connection. The venous collateral pathways were demonstrated by computed tomography and venography

  4. The effect of reduced oxygen content powder on the impact toughness of 316 steel powder joined to 316 steel by low temperature HIP

    International Nuclear Information System (INIS)

    Lind, Anders; Sundstroem, Johan

    2004-11-01

    During the manufacture of the blanket modules, 316L steel powder is simultaneously consolidated and joined to tubes and blocks of 316L materials by Hot Isostatic Pressing (HIP). The high processing temperature can detrimentally increase the grain size of the water cooling tubes in the structure and the blocks reducing their strength. It is well known that surface oxides on the powder particles negatively influence the impact toughness of material and joints consolidated in this way. By increasing the consolidation temperature the metallurgical bonding is improved, due to a redistribution of oxygen within the oxide layer towards more discrete oxide particles. In order to get acceptable mechanical properties of materials produced at a low HIP temperature the oxygen content on the powder surfaces needs to be reduced. The aim of this new techniques to reduce the oxygen content of the metal powder. The influence on Charpy impact energy and tensile strength were demonstrated

  5. Predictors of Venous Thromboembolic Events Associated with Central Venous Port Insertion in Cancer Patients

    Directory of Open Access Journals (Sweden)

    Christine Hohl Moinat

    2014-01-01

    Full Text Available Insertion of central venous port (CVP catheter in the cancer population is associated with increased incidence of venous thromboembolic events (VTE. However, trials have shown limited benefit of antithrombotic treatment to prevent catheter-related venous thrombosis. This prospective observational cohort study was designed to assess the incidence of VTE closely related to CVP implantation in patients with cancer and undergoing chemotherapy, and to identify a high risk subgroup of patients. Between February 2006 and December 2011, 1097 consecutive cancer patients with first CVP implantation were included. Catheter-related VTE were defined as deep venous thrombosis in the arm, with or without pulmonary embolism (PE, or isolated PE. The incidence of CVP-associated VTE was 5.9% (IC95 4.4–7.3% at 3 months, and 11.3% (IC95 9.4–13.2% at 12 months. The incidence of any VTE was 7.6% (IC95 6.0–9.3% at 3 months, and 15.3% (IC95 13.1–17.6% at 12 months. High Khorana risk score and lung cancer were significant predictors of 3 month VTE. In conclusion, this large cohort study of patients with first CVP catheter implantation confirms the high incidence of VTE associated with the CVP implantation and allow identifying high risk patients who may benefit from thromboprophylaxis.

  6. Standard Test Method for Oxygen Content Using a 14-MeV Neutron Activation and Direct-Counting Technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the measurement of oxygen concentration in almost any matrix by using a 14-MeV neutron activation and direct-counting technique. Essentially, the same system may be used to determine oxygen concentrations ranging from over 50 % to about 10 g/g, or less, depending on the sample size and available 14-MeV neutron fluence rates. Note 1 - The range of analysis may be extended by using higher neutron fluence rates, larger samples, and higher counting efficiency detectors. 1.2 This test method may be used on either solid or liquid samples, provided that they can be made to conform in size, shape, and macroscopic density during irradiation and counting to a standard sample of known oxygen content. Several variants of this method have been described in the technical literature. A monograph is available which provides a comprehensive description of the principles of activation analysis using a neutron generator (1). 1.3 The values stated in either SI or inch-pound units are to be regarded...

  7. Mechanochemical endovenous ablation and new frontiers in venous intervention

    NARCIS (Netherlands)

    Boersma, D

    2017-01-01

    Venous insufficiency of the lower extremities is a common condition and related to various symptoms, including venous ulcers. The effect of venous insufficiency on patients’ health-related quality of life is substantial and comparable with other chronic diseases such as arthritis, diabetes, and

  8. Pregnancy-related venous thromboembolism and risk of occult cancer

    DEFF Research Database (Denmark)

    Tarp Hansen, Anette; Veres, Katalin; Horváth-Puhó, Erzsébet

    2017-01-01

    The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected.An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk.......The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected.An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk....

  9. Pregnancy-related venous thromboembolism and risk of occult cancer

    DEFF Research Database (Denmark)

    Hansen, Anette Tarp; Veres, Katalin; Horváth-Puhó, Erzsébet

    2017-01-01

    The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected. An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk.......The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected. An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk....

  10. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  11. Systemic Venous Inflow to the Liver Allograft to Overcome Diffuse Splanchnic Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Cristian Lupascu

    2015-01-01

    Full Text Available Diffuse splanchnic venous thrombosis (DSVT, formerly defined as contraindication for liver transplantation (LT, is a serious challenge to the liver transplant surgeon. Portal vein arterialisation, cavoportal hemitransposition and renoportal anastomosis, and finally combined liver and small bowel transplantation are all possible alternatives to deal with this condition. Five patients with preoperatively confirmed extensive splanchnic venous thrombosis were transplanted using cavoportal hemitransposition (4x and renoportal anastomosis (1x. Median follow-up was 58 months (range: 0,5 to 130 months. Two patients with previous radiation-induced peritoneal injury died, respectively, 18 days and 2 months after transplantation. The three other patients had excellent long-term survival, despite the fact that two of them needed a surgical reintervention for severe gastrointestinal bleeding. Extensive splanchnic venous thrombosis is no longer an absolute contraindication to liver transplantation. Although cavoportal hemitransposition and renoportal anastomosis undoubtedly are life-saving procedures allowing for ensuring adequate allograft portal flow, careful follow-up of these patients remains necessary as both methods are unable to completely eliminate the complications of (segmental portal hypertension.

  12. Estimation of the Influence of Operational Factors on the Oxygen Content of the Turbine Condensate at the Outlet from the Condenser of Steam Turbine

    Directory of Open Access Journals (Sweden)

    Shempelev A. G.

    2017-08-01

    Full Text Available The aim of the article is to analyze the influence of different factors on the oxygen content in the condensate using the example of the condenser of the steam turbine unit T-110/120-130. For the first time, the authors of the article analyze in details how the basic parameters of the condenser's operation (the condenser heat load, the flow and temperature of the cooling water, the air inflow in the condenser, the condition of the heat exchange surface influence the oxygen content of the condensate. The authors come to the conclusion that with standard air inflow in the vacuum system, the equilibrium oxygen content, which corresponds to the norms in the condensate at the condenser outlet, is only possible in its operation modes when the steam flow to the condenser is more than 50% of the nominal flow and cooling water temperatures are equal to or greater than calculated for this type of condenser. The conclusions are confirmed by the experimental material. The results of the research are the basis for the development of measures aimed to increase the deaerating capacity of condensers depending on specific operating conditions.

  13. Cerebrofacial venous metameric syndrome (CVMS) 3: Sturge-Weber syndrome with bilateral lymphatic/venous malformations of the mandible

    International Nuclear Information System (INIS)

    Ramli, N.; Sachet, M.; Bao, C.; Lasjaunias, P.

    2003-01-01

    We present a case of Sturge-Weber syndrome with a bilateral lymphatic/venous malformation of the mandible. Modern biology suggests an explanation for such a case. The classification of cerebrofacial venous metameric syndromes (CVMS) enables us to recognise this lesion as involving the most caudal of the cranial metamere (CVMS 3). (orig.)

  14. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  15. Carbon mineralization and oxygen dynamics in sediments with deep oxygen penetration, Lake Superior

    DEFF Research Database (Denmark)

    Li, Jiying; Crowe, Sean Andrew; Miklesh, David

    2012-01-01

    To understand carbon and oxygen dynamics in sediments with deep oxygen penetration, we investigated eight locations (160–318-m depth) throughout Lake Superior. Despite the 2–4 weight percent organic carbon content, oxygen penetrated into the sediment by 3.5 to > 12 cm at all locations. Such deep ...... volume-specific carbon degradation rates were 0.3–1.5 µmol cm−3 d−1; bioturbation coefficient near the sediment surface was 3–8 cm2 yr−1. These results indicate that carbon cycling in large freshwater systems conforms to many of the same trends as in marine systems.......To understand carbon and oxygen dynamics in sediments with deep oxygen penetration, we investigated eight locations (160–318-m depth) throughout Lake Superior. Despite the 2–4 weight percent organic carbon content, oxygen penetrated into the sediment by 3.5 to > 12 cm at all locations. Such deep......, suggesting that temporal variability in deeply oxygenated sediments may be greater than previously acknowledged. The oxygen uptake rates (4.4–7.7 mmol m−2 d−1, average 6.1 mmol m−2 d−1) and carbon mineralization efficiency (∼ 90% of deposited carbon) were similar to those in marine hemipelagic and pelagic...

  16. Imaging of head and neck venous malformations

    International Nuclear Information System (INIS)

    Flis, Christine M.; Connor, Stephen E.

    2005-01-01

    Venous malformations (VMs) are non proliferative lesions that consist of dysplastic venous channels. The aim of imaging is to characterise the lesion and define its anatomic extent. We will describe the plain film, ultrasound (US) (including colour and duplex Doppler), computed tomography (CT), magnetic resonance imaging (MRI), conventional angiographic and direct phlebographic appearances of venous malformations. They will be illustrated at a number of head and neck locations, including orbit, oral cavity, superficial and deep facial space, supraglottic and intramuscular. An understanding of the classification of such vascular anomalies is required to define the correct therapeutic procedure to employ. Image-guided sclerotherapy alone or in combination with surgery is now the first line treatment option in many cases of head and neck venous malformations, so the radiologist is now an integral part of the multidisciplinary management team. (orig.)

  17. Cardiovascular Pressures with Venous Gas Embolism and Decompression

    Science.gov (United States)

    Butler, B. D.; Robinson, R.; Sutton, T.; Kemper, G. B.

    1995-01-01

    Venous gas embolism (VGE) is reported with decompression to a decreased ambient pressure. With severe decompression, or in cases where an intracardiac septal defect (patent foramen ovale) exists, the venous bubbles can become arterialized and cause neurological decompression illness. Incidence rates of patent foramen ovale in the general population range from 25-34% and yet aviators, astronauts, and deepsea divers who have decompression-induced venous bubbles do not demonstrate neurological symptoms at these high rates. This apparent disparity may be attributable to the normal pressure gradient across the atria of the heart that must be reversed for there to be flow potency. We evaluated the effects of: venous gas embolism (0.025, 0.05 and 0.15 ml/ kg min for 180 min.) hyperbaric decompression; and hypobaric decompression on the pressure gradient across the left and right atria in anesthetized dogs with intact atrial septa. Left ventricular end-diastolic pressure was used as a measure of left atrial pressure. In a total of 92 experimental evaluations in 22 dogs, there were no reported reversals in the mean pressure gradient across the atria; a total of 3 transient reversals occurred during the peak pressure gradient changes. The reasons that decompression-induced venous bubbles do not consistently cause serious symptoms of decompression illness may be that the amount of venous gas does not always cause sufficient pressure reversal across a patent foramen ovale to cause arterialization of the venous bubbles.

  18. Chronic venous disorders

    African Journals Online (AJOL)

    The San Valentino Vascular Screening Project conducted in Italy found a ... developed healthcare systems, the cost of treating advanced venous disease ..... tissue inflammation and necrosis. Sclerosing ... and for its tributaries as an alternative.

  19. Venous Thromboembolism in Patients With Thrombocytopenia

    DEFF Research Database (Denmark)

    Bælum, Jens Kristian; Ellingsen Moe, Espen; Nybo, Mads

    2017-01-01

    BACKGROUND: Venous thromboembolism (VTE) is a frequent and potentially lethal condition. Venous thrombi are mainly constituted of fibrin and red blood cells, but platelets also play an important role in VTE formation. Information about VTE in patients with thrombocytopenia is, however, missing. O...... having thrombocytopenia with VTE seem to be safely treated with anticoagulants without increased occurrence of bleeding....

  20. A BMPy Road for Venous Development.

    Science.gov (United States)

    Goddard, Lauren M; Kahn, Mark L

    2017-09-11

    Detailed molecular pathways for the specific growth of arteries and lymphatic vessels have been identified, but the mechanisms controlling venous vessel growth have been obscure. Tischfield and colleagues (2017) shed new light on this problem by identifying a role for BMP signaling in development of the cerebral venous system. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Duplex imaging of residual venous obstruction to guide duration of therapy for lower extremity deep venous thrombosis.

    Science.gov (United States)

    Stephenson, Elliot J P; Liem, Timothy K

    2015-07-01

    Clinical trials have shown that the presence of ultrasound-identified residual venous obstruction (RVO) on follow-up scanning may be associated with an elevated risk for recurrence, thus providing a potential tool to help determine the optimal duration of anticoagulant therapy. We performed a systematic review to evaluate the clinical utility of post-treatment duplex imaging in predicting venous thromboembolism (VTE) recurrence and in adjusting duration of anticoagulation. The Ovid MEDLINE Database, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Database of Abstracts of Reviews of Effects were queried for the terms residual thrombus or obstruction, duration of therapy, deep vein thrombosis, deep venous thrombosis, DVT, venous thromboembolism, VTE, antithrombotic therapy, and anticoagulation, and 228 studies were selected for review. Six studies determined the rate of VTE recurrence on the basis of the presence or absence of RVO. Findings on venous ultrasound scans frequently remained abnormal in 38% to 80% of patients, despite at least 3 months of therapeutic anticoagulation. In evaluating for VTE recurrence, the definition of RVO varied widely in the literature. Some studies have shown an association between RVO and VTE recurrence, whereas other studies have not. Overall, the presence of RVO is a mild risk factor for recurrence (odds ratio, 1.3-2.0), but only when surveillance imaging is performed soon after the index deep venous thrombosis (3 months). RVO is a mild risk factor for VTE recurrence. The presence or absence of ultrasound-identified RVO has a limited role in guiding the duration of therapeutic anticoagulation. Further research is needed to evaluate its utility relative to other known risk factors for VTE recurrence. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  2. Under general anesthesia arginine vasopressin prevents hypotension but impairs cerebral oxygenation during arthroscopic shoulder surgery in the beach chair position.

    Science.gov (United States)

    Cho, Soo Y; Kim, Seok J; Jeong, Cheol W; Jeong, Chang Y; Chung, Sung S; Lee, JongUn; Yoo, Kyung Y

    2013-12-01

    Patients undergoing surgery in the beach chair position (BCP) are at a risk of cerebral ischemia. We evaluated the effect of arginine vasopressin (AVP) on hemodynamics and cerebral oxygenation during surgery in the BCP. Thirty patients undergoing shoulder surgery in BCP under propofol-remifentanil anesthesia were randomly allocated either to receive IV AVP 0.07 U/kg (AVP group, N = 15) or an equal volume of saline (control group, N = 15) 2 minutes before taking BCP. Mean arterial blood pressure (MAP), heart rate (HR), jugular venous bulb oxygen saturation (SjvO2), and regional cerebral tissue oxygen saturation (SctO2) were measured after induction of anesthesia and before (presitting in supine position) and after patients took BCP. AVP itself given before the positioning increased MAP and decreased SjvO2 and SctO2 (P 20% SctO2 decrease from presitting value) (80% vs 13%; P = 0.0003) was higher in the AVP group. The incidence of jugular desaturation (SjvO2 shoulder surgery under general anesthesia. However, it was associated with regional cerebral but not jugular venous oxygen desaturation on upright positioning.

  3. Improving venous leg ulcer management

    OpenAIRE

    Weller, Carolina Dragica

    2017-01-01

    This thesis reports several different methods to develop and evaluate complex interventions designed to improve venous leg ulcer management. Chronic venous leg ulcers (VLU) are the most common chronic wound problem in the community. Its health and economic burden is predicted to increase due to ageing of the community and increase in prevalence of diabetes and obesity. Although many patients seek health care for VLU, most do not receive the most effective management. Patients with this condi...

  4. Postoperative long-term changes of nutritional and immunological states in patients with esophageal cancer

    International Nuclear Information System (INIS)

    Kimura, Keiko

    1990-01-01

    Under nutritional support, surgical and postoperative adjuvant therapy were performed in 27 patients with thoracic esophageal cancer. The patients were divided into 2 groups, that were patients with postoperative chemotherapy (group A; 13 cases) and patients with postoperative radiation therapy (group B; 14 cases). Nutritional and immunological parameters were measured and compared among each groups. Group B had received higher nutritional support than group A, especially during the period of postoperative therapy. In group B, nutritional and immunological parameters maintained normal level, except serum albumin levels, counts of peripheral lymphocytes and factor XIII. In spite of higher nutritional support, levels of Zn in group B kept low. As for arterio-venous difference of amino acids, the tendency of negative balance in group B was stronger than that in group A. Arginine concentration in venous plasma increased evidently in group B. (author)

  5. Intramedullary Venous Drainage System for Distal Fingertip Replantations.

    Science.gov (United States)

    Purisa, Husrev; Ozturk, Muhammed Besir; Kabakas, Fatih; Mersa, Berkan; Ozcelik, Ismail Bulent; Sezer, Ilker

    2017-08-01

    The number of venous anastomoses performed during fingertip replantation is one of the most important factors affecting the success of replantation. However, because vessel diameters decrease in the zone 1 level, vessel anastomoses, especially vein anastomoses, are technically difficult and, thus, cannot be performed in most cases. Alternative venous drainage methods are crucial when any reliable vein repair is not possible. In the literature, so many artery-only replantation techniques have been defined, such as arteriovenous anastomoses, forming an arteriovenous or venocutaneous fistula, manual milking and massage, puncturing, and external bleeding via a fishmouth incision and using a medical leech. It has been shown that, in distal fingertip replantations, the medullary cavity may also be a good way for venous return. In this study, we introduce an alternative intramedullary venous drainage system we developed to facilitate venous drainage in artery-only fingertip replantations. The results of 24 fingertip replantations distal to the nail fold by using this system are presented with a literature review.

  6. The effect of temperature and oxygen content on coal burnout

    Energy Technology Data Exchange (ETDEWEB)

    K. Milenkova; A.G. Borrego; D. Alvarez; J. Xiberta; R. Menendez [Instituto Nacional del Carbon, CSIC, Oviedo (Spain)

    2003-07-01

    In this study chars from six coals differing in rank and maceral composition have been prepared at 1100 and 1300{sup o}C in a drop tube reactor using four oxygen concentrations (0, 2.5, 10 and 21% oxygen). Char burnout, reactivity, morphology and optical texture have been considered in an attempt to understand the effect of temperature and oxygen concentration in relation to coal characteristics. Temperature has shown to have a different effect on conversion depending on coal rank. The high volatile coals showed similar conversions at 1100 and 1300{sup o}C at the various atmospheres tested, whereas higher rank coals showed higher conversions at 1300 than at 1100{sup o}C. The presence of oxygen in the reacting gas appears to have two opposite effects on coal combustion. On the one hand it prevents swelling and devolatilisation and on the other it enhances combustion. The burnout will depend on which process dominates. In addition, this effect appears to be temperature dependant and the inhibiting effect of oxygen on coal devolatilisation has shown to be higher at higher temperature, since at low temperature it only affects the lowest ranked coals. The presence of oxygen also affects the structure of carbonaceous material since the lower the oxygen concentration the higher the anisotropy development. The difference in temperature separating the two series of experiments (1000 and 1300{sup o}C) did not have a positive effect on the conversion of coals yielding highly porous chars whereas for coals yielding more dense structures higher conversions were achieved at higher temperatures. 7 refs., 5 figs., 1 tab.

  7. Venous compression syndrome of internal jugular veins prevalence in patients with multiple sclerosis and chronic cerebro-spinal venous insufficiency.

    Science.gov (United States)

    Mandolesi, Sandro; Niglio, Tarcisio; Orsini, Augusto; De Sio, Simone; d'Alessandro, Alessandro; Mandolesi, Dimitri; Fedele, Francesco; d'Alessandro, Aldo

    2016-01-01

    Analysis of the incidence of Venous Compression Syndrome (VCS) with full block of the flow of the internal jugular veins (IJVs) in patients with Multiple Sclerosis and Chronic cerebro-spinal venous insufficiency. We included 769 patients with MS and CCSVI (299 males, 470 females) and 210 controls without ms and ccsvi (92 males, 118 females). each subject was investigated by echo-color-doppler (ecd). morphological and hemodynamic ecd data were recorded by a computerized mem-net maps of epidemiological national observatory on ccsvi and they were analyzed by mem-net clinical analysis programs. VCS of IJVs occurs in 240 subjects affected by CCSVI and MS (31% of total) and in 12 controls (6% of total). The differences between the two groups are statistical significant (X² = 36.64, pCerebro-Spinal Venous Insufficiency, Multiple Sclerosis, Venous Compression Syndrome.

  8. Cerebral Microcirculation and Oxygen Tension in the Human Secondary Cortex

    Science.gov (United States)

    Linninger, A. A.; Gould, I. G.; Marinnan, T.; Hsu, C.-Y.; Chojecki, M.; Alaraj, A.

    2013-01-01

    The three-dimensional spatial arrangement of the cortical microcirculatory system is critical for understanding oxygen exchange between blood vessels and brain cells. A three-dimensional computer model of a 3 × 3 × 3 mm3 subsection of the human secondary cortex was constructed to quantify oxygen advection in the microcirculation, tissue oxygen perfusion, and consumption in the human cortex. This computer model accounts for all arterial, capillary and venous blood vessels of the cerebral microvascular bed as well as brain tissue occupying the extravascular space. Microvessels were assembled with optimization algorithms emulating angiogenic growth; a realistic capillary bed was built with space filling procedures. The extravascular tissue was modeled as a porous medium supplied with oxygen by advection–diffusion to match normal metabolic oxygen demand. The resulting synthetic computer generated network matches prior measured morphometrics and fractal patterns of the cortical microvasculature. This morphologically accurate, physiologically consistent, multi-scale computer network of the cerebral microcirculation predicts the oxygen exchange of cortical blood vessels with the surrounding gray matter. Oxygen tension subject to blood pressure and flow conditions were computed and validated for the blood as well as brain tissue. Oxygen gradients along arterioles, capillaries and veins agreed with in vivo trends observed recently in imaging studies within experimental tolerances and uncertainty. PMID:23842693

  9. Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats.

    Science.gov (United States)

    Bachmann, Karin; Kutter, Annette Pn; Schefer, Rahel Jud; Marly-Voquer, Charlotte; Sigrist, Nadja

    2017-08-01

    Objectives The aim of this study was to determine in-house reference intervals (RIs) for venous blood analysis with the RAPIDPoint 500 blood gas analyser using blood gas syringes (BGSs) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGSs. Methods Venous blood was collected from 24 healthy cats and directly transferred into a BGS and an LH tube. The BGS was immediately analysed on the RAPIDPoint 500 followed by the LH tube. The BGSs and LH tubes were compared using paired t-test or Wilcoxon matched-pairs signed-rank test, Bland-Altman and Passing-Bablok analysis. To assess clinical relevance, bias or percentage bias between BGSs and LH tubes was compared with the allowable total error (TEa) recommended for the respective parameter. Results Based on the values obtained from the BGSs, RIs were calculated for the evaluated parameters, including blood gases, electrolytes, glucose and lactate. Values derived from LH tubes showed no significant difference for standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate, while pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionised calcium and anion gap were significantly different to the samples collected in BGSs ( P glucose and lactate can be made based on blood collected in LH tubes and analysed within 5 mins. For pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, anion gap and ionised calcium the clinically relevant alterations have to be considered if analysed in LH tubes.

  10. Water budget of a dam in the semi-arid northeast of Brazil based on oxygen-18 and chlorine contents

    International Nuclear Information System (INIS)

    Stolf, R.; Salati, E.; Menezes Leal, J. de; Fritz, P.

    1979-01-01

    The water balance of an artificial reservoir in the northeast of Brazil is derived by using the variations of oxygen isotopes and chlorine contents. With these two methods, the water losses through subsurface outflow are estimated at 20-40%. A more accurate evaluation would require an investigation of the variability of the relative humidity of the atmosphere. (author)

  11. Cerebral sino-venous thrombosis

    International Nuclear Information System (INIS)

    Sayama, Ichiro; Kobayashi, Tsunesaburo; Nakajima, Kenji

    1982-01-01

    Three cases of cerebral sino-venous thrombosis were reported. Repeated CT findings were studied and discussed on account of the treatments for those pathologic conditions. Those of studied cases are; a 22-year-old postpartum woman, a 42-year-old woman with irregular vaginal bleeding, and a 26-year-old man with severe reactive emesis after drinking alcohol. They were treated conservatively. Case 1 died in its acute stage. In the remaining ones, each had an uneventful recovery. CT scan findings of them manifested their exact clinical conditions. These findings were devided into two categories, one was direct signs expressed sino-venous occlusion, the other was indirect signs which appeared as a result of these occlusion. Direct signs cannot always get in every cases with sino-venous occlusion, but as for indirect signs, we can get various changes corresponding to the time taken CT photoes, and they are useful to decide appropriate treatments at that time. Considering suitable treatments for this disease, it is necessary to select most suitable ones according to their pathologic conditions, which may be precisely drawn with CT scans. (J.P.N.)

  12. Local thrombolysis for patients of severe cerebral venous sinus thrombosis during puerperium

    International Nuclear Information System (INIS)

    Guo, Xin-bin; Fu, Zhenqiang; Song, Lai-jun; Guan, Sheng

    2013-01-01

    Objective: To explore and evaluate the efficacy of intrasinus thrombolysis (IST) in patients with cerebral venous sinus thrombosis (CVST) during postpartum period. Methods: 11 patients during postpartum period with CVST who received IST during July 2007–November 2011 were included. Urokinase was infused into the sinuses via a microcatheter. Magnetic resonance venography (MRV) was performed to assess the recanalization of venous sinuses. Results: Before discharge, the intracranial pressure in 11 patients was under 200 mmH 2 O. MRV confirmed that venous sinus of 9 patients were smooth. The cortex venous and deep venous recovered to normal. Venous sinus of 2 patients recanalized partly, and cortex venous and deep venous had compensation. 9 patients had good outcome and 2 patients had only mild deficits. Conclusion: Intrasinus thrombolysis is safe and effective in patients with severe cerebral venous sinus thrombosis during postpartum period

  13. Clinical quality indicators of venous leg ulcers

    DEFF Research Database (Denmark)

    Kjaer, Monica L; Mainz, Jan; Soernsen, Lars T

    2005-01-01

    In the clinical setting, diagnosis and treatment of venous leg ulcers can vary considerably from patient to patient. The first step to reducing this variation is to document venous leg ulcer care through use of quantitative scientific documentation principles. This requires the development of val...

  14. Risk factors for venous thromboembolism during pregnancy

    DEFF Research Database (Denmark)

    Jensen, Thomas Bo; Gerds, Thomas Alexander; Grøn, Randi

    2013-01-01

    Pregnant women are at an increased risk of venous thromboembolism (VTE). Risk factors for VTE among pregnant women are not sufficiently investigated.......Pregnant women are at an increased risk of venous thromboembolism (VTE). Risk factors for VTE among pregnant women are not sufficiently investigated....

  15. Comparison of local adipose tissue content and SRS-derived NIRS muscle oxygenation measurements in 90 individuals.

    Science.gov (United States)

    Cooper, Chris E; Penfold, Stacey-Marie; Elwell, Clare E; Angus, Caroline

    2010-01-01

    Adipose content in the region over the vastus lateralis muscle was measured in a young (21.1 +/- 3.1 years old, mean +/- SD) population of males (n = 62) and females (n = 28). Three techniques were used: skinfold thickness, ultrasound and near infrared spectroscopy. All techniques closely correlated with each other and all showed a significantly larger adipose content in females and a limited overlap with the range of values in males. Spatially resolved near infrared spectroscopy (SRS-NIRS) was then used to measure the tissue oxygenation index (TOI) at the same site. A source-detector separation of 4 cm was used to allow for significant light penetration into muscle tissue. TOI at rest was significantly higher in the female (65.3 +/- 7.0, mean +/- SD) than the male (61.9 +/- 5.1, mean +/- SD) group. There was a strong positive correlation between adipose content and TOI in male subjects. However, no correlation was seen in the female group. The possible optical and physiological explanations for these results are discussed.

  16. Cardiopulmonary function and oxygen delivery during total liquid ventilation.

    Science.gov (United States)

    Tsagogiorgas, Charalambos; Alb, Markus; Herrmann, Peter; Quintel, Michael; Meinhardt, Juergen P

    2011-10-01

    Total liquid ventilation (TLV) with perfluorocarbons has shown to improve cardiopulmonary function in the injured and immature lung; however there remains controversy over the normal lung. Hemodynamic effects of TLV in the normal lung currently remain undetermined. This study compared changes in cardiopulmonary and circulatory function caused by either liquid or gas tidal volume ventilation. In a prospective, controlled study, 12 non-injured anesthetized, adult New Zealand rabbits were primarily conventionally gas-ventilated (CGV). After instrumentation for continuous recording of arterial (AP), central venous (CVP), left artrial (LAP), pulmonary arterial pressures (PAP), and cardiac output (CO) animals were randomized into (1) CGV group and (2) TLV group. In the TLV group partial liquid ventilation was initiated with instillation of perfluoroctylbromide (12 ml/kg). After 15 min, TLV was established for 3 hr applying a volume-controlled, pressure-limited, time-cycled ventilation mode using a double-piston configured TLV. Controls (CGV) remained gas-ventilated throughout the experiment. During TLV, heart rate, CO, PAP, MAP, CVP, and LAP as well as derived hemodynamic variables, arterial and mixed venous blood gases, oxygen delivery, PVR, and SVR did not differ significantly compared to CGV. Liquid tidal volumes suitable for long-term TLV in non-injured rabbits do not significantly impair CO, blood pressure, and oxygen dynamics when compared to CGV. Copyright © 2011 Wiley-Liss, Inc.

  17. Transarterial embolization for the management of hemarthrosis of the knee

    International Nuclear Information System (INIS)

    Waldenberger, P.; Chemelli, A.; Hennerbichler, A.; Wick, M.; Freund, M.C.; Jaschke, W.; Thaler, M.; Chemelli-Steingruber, I.E.

    2012-01-01

    Background: The purpose of this retrospective study was to evaluate transarterial catheter embolization (TAE) for the management of hemarthrosis of the knee in 35 patients treated at two different hospitals. Methods: From June 1998 through January 2011, 35 patients (22 men and 13 women, mean age 57 years) underwent TAE for hemarthrosis of the knee using polyvinyl alcohol particles (PVA particles), multi-curled 0.018 in. microcoils or a combination of both. In one patient a detachable microcoil was used. Hemarthrosis developed after arthroscopy in 9, after trauma in 3, after arthroplasty in 18 and after sepsis in 2 patients. 2 patients had severe gonarthrosis and in one patient hemarthrosis was due to Marfan's syndrome. Angiographies showed abnormal and increased vasculature in 23 patients, one or more pseudoaneurysms in 8 and arterio-venous fistula in 2 patients. One patient showed both, pseudoaneurysm and hypervascularization and another one pseudoaneurysm and arterio-venous fistula. Results: Technical success was achieved in 100%. None of the patients developed procedure-related complications such as periarticular skin- or tissue necrosis, including a patient who underwent TAE of two different bleeding sources in two consecutive sessions. Clinical success was 93.4%. Two patients showed recurrent swelling of the knee, 377 and 824 days after TAE respectively. However, only one of them required secondary TAE because of abnormal and increased vasculature. Conclusions: In our view, TAE is the treatment of choice for the management of hemarthrosis of the knee. It is an effective and minimally invasive technique with very low complication rates

  18. Transarterial embolization for the management of hemarthrosis of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Waldenberger, P., E-mail: peter.waldenberger@bhs.at [Department of Radiology, Hospital of the Sisters of Charity, Linz (Austria); Chemelli, A., E-mail: andreas.chemelli@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria); Hennerbichler, A., E-mail: alfred.hennerbichler@i-med.ac.at [Department of Trauma Surgery, Innsbruck Medical University (Austria); Wick, M., E-mail: marius.wick@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria); Freund, M.C., E-mail: martin.freund@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria); Jaschke, W., E-mail: werner.jaschke@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria); Thaler, M., E-mail: martin.thaler@i-med.ac.at [Department of Orthopedic Surgery, Innsbruck Medical University (Austria); Chemelli-Steingruber, I.E., E-mail: iris.chemelli-steingruber@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria)

    2012-10-15

    Background: The purpose of this retrospective study was to evaluate transarterial catheter embolization (TAE) for the management of hemarthrosis of the knee in 35 patients treated at two different hospitals. Methods: From June 1998 through January 2011, 35 patients (22 men and 13 women, mean age 57 years) underwent TAE for hemarthrosis of the knee using polyvinyl alcohol particles (PVA particles), multi-curled 0.018 in. microcoils or a combination of both. In one patient a detachable microcoil was used. Hemarthrosis developed after arthroscopy in 9, after trauma in 3, after arthroplasty in 18 and after sepsis in 2 patients. 2 patients had severe gonarthrosis and in one patient hemarthrosis was due to Marfan's syndrome. Angiographies showed abnormal and increased vasculature in 23 patients, one or more pseudoaneurysms in 8 and arterio-venous fistula in 2 patients. One patient showed both, pseudoaneurysm and hypervascularization and another one pseudoaneurysm and arterio-venous fistula. Results: Technical success was achieved in 100%. None of the patients developed procedure-related complications such as periarticular skin- or tissue necrosis, including a patient who underwent TAE of two different bleeding sources in two consecutive sessions. Clinical success was 93.4%. Two patients showed recurrent swelling of the knee, 377 and 824 days after TAE respectively. However, only one of them required secondary TAE because of abnormal and increased vasculature. Conclusions: In our view, TAE is the treatment of choice for the management of hemarthrosis of the knee. It is an effective and minimally invasive technique with very low complication rates.

  19. Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage

    Science.gov (United States)

    Shen, Tao; Baker, Keith

    2015-01-01

    Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…

  20. Mesenteric venous thrombosis after prolonged air travel-a case report

    Directory of Open Access Journals (Sweden)

    Joaquín Salas-Coronas

    2014-07-01

    Full Text Available We present a case of acute mesenteric venous thrombosis after a long distance flight in a traveller presenting with abdominal pain, diarrhoea and vomiting within 48 h of prolonged immobility situation. Venous thrombosis in the lower limbs and venous thromboembolism has been clearly associated with prolonged air travel (economy class syndrome. Thrombosis was diagnosed by computed tomography of the abdomen, and after starting anticoagulant therapy with acenocumarol, symptoms yielded completely in a few weeks. The study of thrombophilia was negative, although the existence of two first-degree relatives (mother and grandmother with a history of venous thrombosis with a history of venous thrombosis makes it likely a situation of inherited thrombophilia. Although exceptional, mesenteric venous thrombosis should be considered in travellers with acute abdominal pain after prolonged air travel when there are thrombophilic conditions.

  1. Local thrombolysis for patients of severe cerebral venous sinus thrombosis during puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xin-bin, E-mail: gxb3906080@sina.com [Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Fu, Zhenqiang, E-mail: fuzhenqiang1005@163.com [Department of Neurology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Song, Lai-jun, E-mail: laijunsong@sina.com [Department of Neurosurgery, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Guan, Sheng, E-mail: gsradio@126.com [Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China)

    2013-01-15

    Objective: To explore and evaluate the efficacy of intrasinus thrombolysis (IST) in patients with cerebral venous sinus thrombosis (CVST) during postpartum period. Methods: 11 patients during postpartum period with CVST who received IST during July 2007–November 2011 were included. Urokinase was infused into the sinuses via a microcatheter. Magnetic resonance venography (MRV) was performed to assess the recanalization of venous sinuses. Results: Before discharge, the intracranial pressure in 11 patients was under 200 mmH{sub 2}O. MRV confirmed that venous sinus of 9 patients were smooth. The cortex venous and deep venous recovered to normal. Venous sinus of 2 patients recanalized partly, and cortex venous and deep venous had compensation. 9 patients had good outcome and 2 patients had only mild deficits. Conclusion: Intrasinus thrombolysis is safe and effective in patients with severe cerebral venous sinus thrombosis during postpartum period.

  2. [Emphysematous gastritis with concomitant portal venous air].

    Science.gov (United States)

    Jeong, Min Yeong; Kim, Jin Il; Kim, Jae Young; Kim, Hyun Ho; Jo, Ik Hyun; Seo, Jae Hyun; Kim, Il Kyu; Cheung, Dae Young

    2015-02-01

    Emphysematous gastritis is a rare form of gastritis caused by infection of the stomach wall by gas forming bacteria. It is a very rare condition that carries a high mortality rate. Portal venous gas shadow represents elevation of intestinal luminal pressure which manifests as emphysematous gastritis or gastric emphysema. Literature reviews show that the mortality rate is especially high when portal venous gas shadow is present on CT scan. Until recently, the treatment of emphysematous gastritis has been immediate surgical intervention. However, there is a recent trend of avoiding surgery because of the frequent occurrence of post-operative complications such as anastomosis leakage. In addition, aggressive surgical treatment has failed to show significant improvement in prognosis. Recently, the authors experienced a case of emphysematous gastritis accompanied by portal venous gas which was treated successfully by conservative treatment without immediate surgical intervention. Herein, we present a case of emphysematous gastritis with concomitant portal venous air along with literature review.

  3. [Venous thromboembolic disease: presentation of a case].

    Science.gov (United States)

    Mirpuri-Mirpuri, P G; Álvarez-Cordovés, M M; Pérez-Monje, A

    2013-01-01

    Venous thromboembolic disease in its clinical spectrum includes both deep vein thrombosis and pulmonary thromboembolism, which is usually a complication of deep vein thrombosis. It is a relatively common disease with significant morbidity and requires an accurate diagnosis. They are numerous risk factors for venous thromboembolism, and there is evidence that the risk of thromboembolic disease increases proportionally to the number of predisposing risk factors present. The primary care physician should know the risk factors and suspect the presence of venous thromboembolic disease when there is a compatible clnical picture. The treatment for this pathology is anticoagulation. We report a patient with cardiovascular risk factors who was seen with pain in the right leg and shortness of breath and referred to the hospital with suspected venous thromboembolism, atrial fibrillation and pleural effusion. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  4. Pathophysiology of spontaneous venous gas embolism

    Science.gov (United States)

    Lambertsen, C. J.; Albertine, K. H.; Pisarello, J. B.; Flores, N. D.

    1991-01-01

    The use of controllable degrees and durations of continuous isobaric counterdiffusion venous gas embolism to investigate effects of venous gas embolism upon blood, cardiovascular, and respiratory gas exchange function, as well as pathological effects upon the lung and its microcirculation is discussed. Use of N2O/He counterdiffusion permitted performance of the pathophysiologic and pulmonary microstructural effects at one ATA without hyperbaric or hypobaric exposures.

  5. Iliofemoral and iliocaval interventions in deep venous thrombosis

    International Nuclear Information System (INIS)

    Haage, P.; Guenther, R.W.

    2005-01-01

    Significant spontaneous thrombus disintegration in deep venous thrombosis (DVT) occurs very infrequently. On the contrary, these thrombi are prone to appositional growth and migration into the pulmonary arteries. The development of chronic venous insufficiency due to post-thrombotic syndrome is a frequent consequence of DVT. Therapeutic options in DVT include anticoagulation and recanalising procedures such as thrombolysis and thrombectomy. After appropriate indication assessment, the interventional radiologist can offer an efficacy-proven minimally-invasive vessel restitution approach by performing locoregional thrombolysis, pharmacomechanical therapy or, particularly in iliocaval thrombosis, mechanical thrombectomy. These methods not only serve to restitute of vessel patency, but also allow preserving venous valve function. In DVT with recurrent pulmonary embolism, retrievable filters with extended implantation duration can be deployed. In chronic proximal venous flow obstruction or in case of significant residual stenosis after thrombolysis, balloon angioplasty with stent implantation is the treatment modality of choice. Consequently, the radiologist can adopt an important role in the treatment of extensive venous disease. In this article, the treatment modalities concerning iliofemoral and iliocaval thrombosis are demonstrated and illustrated. (orig.)

  6. Effects of Intensified Vasodilatory Antihypertensive Treatment on Renal Function, Blood supply and Oxygenation in Chronic Kidney Disease

    DEFF Research Database (Denmark)

    Khatir, Dinah Sherzad; Pedersen, Michael; Ivarsen, Per

    2015-01-01

    -blocker metoprolol). At baseline and following 18 months of therapy we determined forearm resistance by venous occlusion plethysmography. Using magnetic resonance imaging (MRI) renal artery blood flow was measured for calculation of RVR, and blood oxygen level dependent (BOLD) MRI was used as a marker of renal...

  7. Emulsifiers' composition modulates venous irritation of the nanoemulsions as a lipophilic and venous irritant drug delivery system.

    Science.gov (United States)

    Mao, Chengwen; Wan, Jiangling; Chen, Huabing; Xu, Huibi; Yang, Xiangliang

    2009-01-01

    In this study, a nanoemulsion (NE) system was investigated for intravenous delivery of lipophilic and venous irritant drugs. NEs were prepared to deliver diallyl trisulfide (DT) for systemic therapy of bacterial and fungal infection, egg phospholipid was chosen as the main emulsifier, and two co-emulsifiers were also incorporated, including Poloxamer 188 (P188) and Solutol HS 15 (S15). Soybean oil was used as the dispersed phases, forming stable DT NEs with small particle sizes. The venous irritation of DT NEs was evaluated by in vitro human umbilical cord endothelial cells (CRL 1730) compatibility model with the intracellular adenosine triphosphate (ATP) and guanosine triphosphate (GTP) concentrations as the indices. The intracellular ATP and GTP reduction changed with the incorporation of a variety of co-emulsifiers, which varied in a free DT concentration-dependent manner. It was deduced that the free DT concentrations of NEs containing co-emulsifiers were determined by the partition coefficient of DT between oil and surfactant buffer solution. In conclusion, NE was an appropriate delivery system for lipophilic and venous irritant drug, and optimization of the composition of emulsifiers was an effective method to alleviate the venous irritation of DT NEs.

  8. Systemic treatments for the prevention of venous thrombo-embolic events in paediatric cancer patients with tunnelled central venous catheters

    NARCIS (Netherlands)

    Schoot, Reineke A.; Kremer, Leontien C. M.; van de Wetering, Marianne D.; van Ommen, Cornelia H.

    2013-01-01

    Venous thrombo-embolic events (VTEs) occur in 2.2% to 14% of paediatric cancer patients and cause significant morbidity and mortality. The malignant disease itself, the cancer treatment and the presence of central venous catheters (CVCs) increase the risk of VTE. The primary objective of this review

  9. Activation-induced resetting of cerebral oxygen and glucose uptake in the rat

    DEFF Research Database (Denmark)

    Madsen, P L; Linde, R; Hasselbalch, S G

    1998-01-01

    In the clinical setting it has been shown that activation will increase cerebral glucose uptake in excess of cerebral oxygen uptake. To study this phenomenon further, this study presents an experimental setup that enables precise determination of the ratio between cerebral uptake of glucose...... and oxygen in the awake rat. Global CBF was measured by the Kety-Schmidt technique, and the ratio between cerebral uptake rates for oxygen, glucose, and lactate was calculated from cerebral arterial-venous differences. During baseline conditions, rats were kept in a closed box designed to minimize...... interference. During baseline conditions CBF was 1.08 +/- 0.25 mL x g(-1) x minute(-1), and the cerebral oxygen to glucose uptake ratio was 5.5. Activation was induced by opening the sheltering box for 6 minutes. Activation increased CBF to 1.81 mL x g(-1) x minute(-1). During activation cerebral glucose...

  10. [The unnecessary application of central venous catheterization in surgical patients].

    Science.gov (United States)

    Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko

    2018-04-06

    Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on

  11. Cerebral venous angioma

    International Nuclear Information System (INIS)

    Inagawa, Tetsuji; Taguchi, Haruyoshi; Kamiya, Kazuko; Yano, Takashi; Nakajima, Reiko

    1984-01-01

    This report presents a 27-year-old male patient who was diagnosed as having cerebral venous angioma in the postero-temporal area by CT scan and cerebral angiography. The patient improved by removing angioma with electrocoagulation of medullary veins. (Namekawa, K.)

  12. Venous ulcers of the lower limb: Where do we stand?

    Directory of Open Access Journals (Sweden)

    Chatterjee S Sasanka

    2012-01-01

    Full Text Available Venous ulcers are the most common ulcers of the lower limb. It has a high morbidity and results in economic strain both at a personal and at a state level. Chronic venous hypertension either due to primary or secondary venous disease with perforator paucity, destruction or incompetence resulting in reflux is the underlying pathology, but inflammatory reactions mediated through leucocytes, platelet adhesion, formation of pericapillary fibrin cuff, growth factors and macromolecules trapped in tissue result in tissue hypoxia, cell death and ulceration. Duplex scan with colour flow is the most useful investigation for venous disease supplying information about patency, reflux, effects of proximal and distal compression, Valsalva maneuver and effects of muscle contraction. Most venous disease can be managed conservatively by leg elevation and compression bandaging. Drugs of proven benefit in venous disease are pentoxifylline and aspirin, but they work best in conjunction with compression therapy. Once ulceration is chronic or the patient does not respond to or cannot maintain conservative regime, surgical intervention treating the underlying venous hypertension and cover for the ulcer is necessary. The different modalities like sclerotherapy, ligation and stripping of superficial varicose veins, endoscopic subfascial perforator ligation, endovenous laser or radiofrequency ablation have similar long-term results, although short-term recovery is best with radiofrequency and foam sclerotherapy. For deep venous reflux, surgical modalities include repair of incompetent venous valves or transplant or transposition of a competent vein segment with normal valves to replace a post-thrombotic destroyed portion of the deep vein.

  13. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  14. Venous leg ulcers

    Science.gov (United States)

    2008-01-01

    Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2007 (BMJ Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 80 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri

  15. In the absence of a central venous catheter, risk of venous thromboembolism is low in critically injured children, adolescents, and young adults: evidence from the National Trauma Data Bank.

    Science.gov (United States)

    O'Brien, Sarah H; Candrilli, Sean D

    2011-05-01

    To describe the incidence and risk factors of venous thromboembolism in a large sample of critical care pediatric, adolescent, and young adult trauma patients. The National Trauma Data Bank-the largest and most complete aggregation of trauma registry data in the United States. Seven hundred eighty-four level I to level IV trauma centers. Patients ≤ 21 yrs of age who spent at least 1 day in a critical care unit during a trauma admission between 2001 and 2005. To characterize differences between patients with and without venous thromboembolism, we extracted variables regarding patient demographics, injury pattern and severity, procedures, total length of stay, and intensive care unit and ventilator days. Odds ratios for predictors of venous thromboembolism were estimated with a logistic regression model. Among the 135,032 critical care patients analyzed, venous thromboembolism was uncommon (6 per 1,000 discharges). Placement of a central venous catheter was a significant predictor of venous thromboembolism (odds ratio = 2.24; p central venous catheter were of even greater magnitude, particularly in adolescents and young adults. The risk of venous thromboembolism in critical care patients without a central venous catheter was central venous access.

  16. Anatomical features of venous outflow from rat’s reproductive organs

    Directory of Open Access Journals (Sweden)

    N. A. Nikitin

    2012-01-01

    Full Text Available The venous drainage from reproductive organs of rats is described; new data on peculiarities of the venous drainage are obtained.Objects of study were adult Wistar white rats (20 animals. The animals have passed precision dissection of vessels in order to study anatomic peculiarities of venous drainage from the left spermary in male rats and internal genital organs in female rats in norm. It has been shown that the venous drainage from the left spermary follows the spermatic vein entering into the pampiniform plexus system, which continues into the single venous trunk, which, in its turn, divides into the ascending and descending veins. The descending vein runs into the common left iliac vein, while the ascending vein runs into the renal vein. The venous drainage from female reproductive organs follows through the uterine vein, which, taking the tubal and spermatic veins, runs from the left into the left renal vein and from the right into the caudal vena cava.

  17. Autologous blood sequestration using a double venous reservoir bypass circuit and polymerized hemoglobin prime.

    Science.gov (United States)

    Neragi-Miandoab, Siyamek; Guerrero, J Luis; Vlahakes, Gus J

    2002-01-01

    Cardiac surgery often necessitates transfusion of homologous blood. Hemoglobin based oxygen carrying solutions (HBOCs) transport oxygen, suggesting use in cardiopulmonary bypass. HBOC was used in a novel oxygenator double-reservoir circuit that permits acute sequestration of a portion of the autologous blood volume during bypass. Two groups of seven mongrel dogs each were studied in an experimental bypass model using global myocardial ischemia and cardioplegia protection: HBOC group, initial venous return drained to a separate reservoir and hypothermic bypass was conducted with HBOC containing perfusate in a second bypass reservoir; Control group, crystalloid prime in a conventional circuit. Hemodynamics and metabolic and hematologic parameters were measured before and 60 min after aortic clamp removal and reinfusion of sequestered autologous blood. Blood gases, base excess, hematocrit, total hemoglobin, and platelet counts were measured. In the HBOC group, metabolic acidosis did not occur, and ventricular function was preserved. Net conservation of platelets was noted at study conclusion: control 33+/-13 x 10(3) per mm3 versus HBOC 48+/-13 x 10(3), p conservation of the platelet mass occurs, a portion of which is not exposed to the deleterious effects of hypothermia and cardiopulmonary bypass.

  18. Effect of body position and oxygen tension on foramen ovale recruitment.

    Science.gov (United States)

    Moses, Kayla L; Beshish, Arij G; Heinowski, Nicole; Baker, Kim R; Pegelow, David F; Eldridge, Marlowe W; Bates, Melissa L

    2015-01-01

    While there is an increased prevalence of stroke at altitude in individuals who are considered to be low risk for thrombotic events, it is uncertain how venous thrombi reach the brain. The patent foramen ovale (PFO) is a recruitable intracardiac shunt between the right and left atrium. We aimed to determine whether body position and oxygen tension affect blood flow through the PFO in healthy adults. We hypothesized that hypoxia and body positions that promote right atrial filling would independently recruit the PFO. Subjects with a PFO (n = 11) performed 11 trials, combining four different fractions of inhaled oxygen (FiO₂) (1.0, 0.21, 0.15, and 0.10) and three positions (upright, supine, and 45° head down), with the exception of FiO₂ = 0.10, while 45° head down. After 5 min in each position, breathing the prescribed oxygen tension, saline bubbles were injected into an antecubital vein and a four-chamber echocardiogram was obtained to evaluate PFO recruitment. We observed a high incidence of PFO recruitment in all conditions, with increased recruitment in response to severe hypoxia and some contribution of body position at moderate levels of hypoxia. We suspect that increased pulmonary vascular pressure, secondary to hypoxia-induced pulmonary vasoconstriction, increased right atrial pressure enough to recruit the PFO. Additionally, we hypothesize that the minor increase in breathing resistance that was added by the mouthpiece, used during experimental trials, affected intrathoracic pressure and venous return sufficiently to recruit the PFO. Copyright © 2015 the American Physiological Society.

  19. Central venous obstruction in the thorax

    International Nuclear Information System (INIS)

    Collin, G.; Jones, R.G.; Willis, A.P.

    2015-01-01

    Central venous stenosis and occlusion can occur secondary to a spectrum of conditions ranging from aggressive malignancy to benign extrinsic anatomical compression in otherwise healthy individuals. Irrespective of aetiology, significant morbidity in the acute setting and long term can occur unless prompt accurate diagnosis and appropriate management is initiated, the radiologist being central to both. The present review will provide radiologists with a thorough illustration and explanation of the range of central venous conditions in the thorax (including deep vein thrombosis, thoracic outlet syndrome, haemodialysis, and malignancy related causes), the salient imaging findings and interventional management using case examples from the authors' practice. - Highlights: • We show a range of causes of central venous disease in the thorax. • We provide information about different imaging and management strategies. • We show several cases with successes and complications of endovascular management

  20. Oxygen requirements of the earliest animals

    DEFF Research Database (Denmark)

    Mills, Daniel Brady; Ward, Lewis M.; Jones, CarriAyne

    2014-01-01

    likely exhibited a physiology and morphology similar to that of a modern sponge, its oxygen demands may have been met well before the enhanced oxygenation of the Ediacaran Period. Therefore, the origin of animals may not have been triggered by a contemporaneous rise in the oxygen content...

  1. Contribution of MRI in supracardiac total anomalous pulmonary venous drainage

    International Nuclear Information System (INIS)

    Kastler, B.; Germain, P.; Gangi, A.; Klinkert, A.; Dietemann, J.L.; Wackenheim, A.; Livolsi, A.; Willard, D.

    1992-01-01

    A case of supracardiac total anomalous pulmonary venous drainage (TAPVD) in an infant aged 2 1/2 months is presented. Diagnosis was established non invasively by magnetic resonance image (MRI). Not only did MRI precisely depict the anomalous venous pathway but it moreover securely excluded pulmonary venous obstruction. (orig.)

  2. Partial anomalous pulmonary venous return in Turner syndrome.

    Science.gov (United States)

    van den Hoven, Allard T; Chelu, Raluca G; Duijnhouwer, Anthonie L; Demulier, Laurent; Devos, Daniel; Nieman, Koen; Witsenburg, Maarten; van den Bosch, Annemien E; Loeys, Bart L; van Hagen, Iris M; Roos-Hesselink, Jolien W

    2017-10-01

    The aim of this study is to describe the prevalence, anatomy, associations and clinical impact of partial anomalous pulmonary venous return in patients with Turner syndrome. All Turner patients who presented at our Turner clinic, between January 2007 and October 2015 were included in this study and underwent ECG, echocardiography and advanced imaging such as cardiac magnetic resonance or computed tomography as part of their regular clinical workup. All imaging was re-evaluated and detailed anatomy was described. Partial anomalous pulmonary venous return was diagnosed in 24 (25%) out of 96 Turner patients included and 14 (58%) of these 24 partial anomalous pulmonary venous return had not been reported previously. Right atrial or ventricular dilatation was present in 11 (46%) of 24 partial anomalous pulmonary venous return patients. When studied with advanced imaging modalities and looked for with specific attention, PAPVR is found in 1 out of 4 Turner patients. Half of these patients had right atrial and/or ventricular dilatation. Evaluation of pulmonary venous return should be included in the standard protocol in all Turner patients. Copyright © 2017. Published by Elsevier B.V.

  3. Oxygen measurements in thin ribbon silicon

    Energy Technology Data Exchange (ETDEWEB)

    Hyland, S L; Ast, D G; Baghdadi, A

    1987-03-01

    The oxygen content of thin silicon ribbons grown by the dendritic web technique was measured using a modification of the ASTM method based on Fourier transform infrared spectroscopy. Web silicon was found to have a high oxygen content, ranging from 13 to 19 ppma, calculated from the absorption peak associated with interstitial oxygen and using the new ASTM conversion coefficient. The oxygen concentration changed by about 10% along the growth direction of the ribbon. In some samples, a shoulder was detected on the absorption peak. A similar shoulder in Czochralski grown material has been variously interpreted in the literature as due to a complex of silicon, oxygen, and vacancies, or to a phase of SiO/sub 2/ developed along dislocations in the material. In the case of web silicon, it is not clear which is the correct interpretation.

  4. A survey of current practice of vascular surgeons in venous disease management.

    Science.gov (United States)

    Bush, Ruth L; Gloviczki, Peter

    2013-01-01

    Acute venous thromboembolism and chronic venous diseases are common conditions that affect a large proportion of the United States population. The diagnosis of venous disease has improved, and the treatment options have rapidly evolved over the past decade. To date, it is unclear to what extent vascular surgeons have become involved in the modern management of venous disorders. This survey was undertaken to explore the current interest and practice of vascular surgeons in the contemporary care of venous disease. A survey was administered via a web-based platform to active and candidate members of the Society for Vascular Surgery (SVS). The survey included 30 questions investigating the characteristics of venous surgeons and scope of venous practice. Open-ended questions were also included for commentary. A total of 1879 surveys were sent to SVS members nationwide, and 385 members participated (response rate of 20.5%). The participants were mostly men (89.6%) with 37.7% practicing in an academic setting and 59.2% in private practice. The respondents treated superficial veins (92.9%) and deep veins (85.8%) in clinical practice, with 89.9% having their own vascular laboratory. A wide spectrum of interventions for superficial (91.9%), deep (85.8%), and perforator veins (52.7% endovenous, 19.4% subfascial endoscopic perforator surgery) are being performed by respondents. Only 26.2% had learned endovenous thermal ablation in their training program; however, over 96% of those performing venous interventions utilized this technique. Overall, the majority (85.5%) devoted 50% or less of practice to venous disorders. Respondents indicated that limitations to expansion of vein practices mainly involved challenges with third party payers, local competition, and existing large volumes of arterial interventions needing to be performed. Despite the widespread incorporation of venous disease into current vascular practices, 66.1% are not members of the American Venous Forum (AVF

  5. [Superficial venous thrombosis. A state of art].

    Science.gov (United States)

    Sándor, Tamás

    2017-01-01

    For a long time superficial thrombophlebitis has been thought to be a rather benign condition. Recently, when duplex ultrasound technique is used for the diagnosis more and more often, the disease is proved to be more dangerous than anticipated. Thrombosis propagates to the deep veins in 6-44% and pulmonary embolism was observed on the patients in 1,5-33%. We can calculate venous thromboembolic complications on every fourth patient. Diagnosis is clinical, but duplex ultrasound examination is mandatory, for estimation of the thrombus extent, for exclusion of the deep venous thrombosis and for follow up. Both legs should be checked with ultrasound, because simultaneous deep venous thrombosis can develop on the contralateral limb. Two different forms can be distinguished: superficial venous thrombosis with, or without varicose veins. In cases of spontaneous, non varicous form, especially when the process is migrating or recurrent, a careful clinical examination is necessery for exclusion of malignant diseases and thrombophilia. The treatment options are summarised on the basis of recent international consensus statements. The American and German guidelines are similar. Compression and mobilisation are cornerstones of the therapy. For a short segment thrombosis non steroidal antiinflammatory drugs are effective. For longer segments low molecular-weight heparins are preferred. Information on the effect of the novel oral anticoagulants for the therapy is lacking but they may appear to be effective in the future for this indication. When thrombus is close to the sapheno-femoral or sapheno-popliteal junction crossectomy (high ligation), or low molecular-weight heparin in therapeutic doses are indicated. The term superficial thrombophlebitis should be discouraged, because inflammation and infection is not the primary pathology. It should be called correctly superficial venous thrombosis in order to avoid the unnecessary administration of antibiotics and the misconception

  6. Noninvasive optical quantification of absolute blood flow, blood oxygenation, and oxygen consumption rate in exercising skeletal muscle

    Science.gov (United States)

    Gurley, Katelyn; Shang, Yu; Yu, Guoqiang

    2012-07-01

    This study investigates a method using novel hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] to obtain continuous, noninvasive measurement of absolute blood flow (BF), blood oxygenation, and oxygen consumption rate (\\Vdot O2) in exercising skeletal muscle. Healthy subjects (n=9) performed a handgrip exercise to increase BF and \\Vdot O2 in forearm flexor muscles, while a hybrid optical probe on the skin surface directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO2], [Hb], and THC), tissue oxygen saturation (StO2), relative BF (rBF), and relative oxygen consumption rate (r\\Vdot O2). The rBF and r\\Vdot O2 signals were calibrated with absolute baseline BF and \\Vdot O2 obtained through venous and arterial occlusions, respectively. Known problems with muscle-fiber motion artifacts in optical measurements during exercise were mitigated using a novel gating algorithm that determined muscle contraction status based on control signals from a dynamometer. Results were consistent with previous findings in the literature. This study supports the application of NIRS/DCS technology to quantitatively evaluate hemodynamic and metabolic parameters in exercising skeletal muscle and holds promise for improving diagnosis and treatment evaluation for patients suffering from diseases affecting skeletal muscle and advancing fundamental understanding of muscle and exercise physiology.

  7. Venous function after pharmacomechanical thrombolysis for extensive iliofemoral deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Wim Greeff

    2017-08-01

    Full Text Available Background: Chronic venous insufficiency is an important complication following iliofemoral deep venous thrombosis. Early thrombus removal may preserve venous function and prevent this complication. This study represents the largest reported South African series of pharmacomechanical thrombolysis for iliofemoral deep venous thrombosis to date. Objective: To evaluate the long-term outcome following pharmacomechanical thrombolysis for proximal and extensive deep venous thrombosis in a private, specialist vascular unit. Methods: All patients who underwent pharmacomechanical thrombolysis for iliofemoral deep venous thrombosis between August 2009 and January 2016 were invited to return for clinical assessment and venous ultrasound. Clinical findings were recorded according to the Villalta score and clinical, etiology, anatomic and pathology (CEAP classification. The quality of life (QoL was assessed utilising the VEINES-QoL/Sym questionnaire, providing two scores per patient, one describing the QoL and the other symptom severity (Sym. Results: Thirty two patients (35 legs were evaluated. There were 25 females and 7 males, with a mean age of 33.5 years (±14 years. The mean follow-up period was 31 months (range 3 months – 80 months. Results of the CEAP classification were C0 = 24 (75%, C1 = 1 (4%, C2 = 2 (6%, C3 = 2 (6% and C4 = 3 (9%. Thirty-one (97% patients had Villalta scores from 0 to 4, indicating no or mild evidence of venous disease. One patient (3% had a Villalta score of 6, indicating post-thrombotic syndrome. The mean QoL score was 87% (±12 and the mean Sym score was 86% (±14. Twenty-four (75% patients had no abnormality on ultrasound, with fibrosis the most observed abnormality. Conclusion: Most patients who had undergone pharmacomechanical thrombolysis for extensive iliofemoral deep venous thrombosis showed few significant clinical signs of chronic venous insufficiency, had excellent function on venous ultrasound and reported

  8. The Essentials of Parathyroid Hormone Venous Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [NYU Langone Medical Center, Department of Radiology, NYU School of Medicine (United States); Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology (United States); Sacks, Barry, E-mail: bsacks@bidmc.harvard.edu [Beth Israel Deaconess Medical Center, Department of Interventional Radiology (United States); Oklu, Rahmi, E-mail: oklu.rahmi@mayo.edu [Mayo Clinic, Department of Interventional Radiology (United States); Deipolyi, Amy, E-mail: deipolya@mskcc.org [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States)

    2017-01-15

    Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage. Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.

  9. MRI in venous thromboembolic disease

    International Nuclear Information System (INIS)

    Sostman, H.D.; Debatin, J.F.; Spritzer, C.E.; Coleman, R.E.; Grist, T.M.; MacFall, J.R.

    1993-01-01

    We evaluated the ability of magnetic resonance (MR) imaging to detect deep venous thrombosis (DVT) and pulmonary embolism (PE). MR venography was performed on 217 patients suspected of having DVT. Cine-MR imaging of the pulmonary arteries was performed in 14 other patients who were thought to have PE based on other imaging studies. In a third group of 5 patients, MR pulmonary angiograms were performed in the sagittal and coronal planes with a multislice fast gradient recalled echo technique. All but one of the 217 MR venograms were technically adequate. In 72 patients with correlative imaging studies (venography and ultrasound) MR venography was 99% sensitive and 95% specific. On the basis of follow-up (mean 8.3 months), no false-negative MR venograms were detected in an additional 64 patients. In 11 other patients MR revealed a diagnosis other than DVT. Cine-MR showed PE in all 14 patients evaluated. MR pulmonary arteriography demonstrated filling defects consistent with acute PE in 2 of 3 patients with acute PE; in the third patient only a questionable filling defect was seen. Coarctations or webs were found in the pulmonary arteries of both patients with chronic PE. These preliminary data suggest that MR imaging may be able to evaluate both the peripheral venous and the pulmonary arterial component of venous thromboembolic disease. Further technical refinement and more extensive clinical experience will be required to establish the role of this method in diagnosing pulmonary embolism, but MR venography is now used routinely in our hospital for the diagnosis of deep venous thrombosis. (orig.)

  10. Correlação entre gasometria atrial direita e índice cardíaco no pós-operatório de cirurgia cardíaca Correlation between right atrial venous blood gasometry and cardiac index in cardiac surgery postoperative period

    Directory of Open Access Journals (Sweden)

    João Jackson Duarte

    2010-06-01

    Full Text Available OBJETIVO: Determinar a confiabilidade em se correlacionar o índice cardíaco com os dados fornecidos pela gasometria do sangue venoso atrial direito em pacientes submetidos à cirurgia cardíaca, durante o período pós-operatório. MÉTODOS: A partir das amostras de sangue arterial e venoso do átrio direito, colhidas no pós-operatório de cirurgia cardíaca, foram determinados os parâmetros de oxigênio do sangue venoso do átrio direito. Estes parâmetros foram então comparados com o índice cardíaco determinado pela termodiluição. RESULTADOS: Houve boa correlação entre a saturação de oxigênio do sangue venoso do átrio direito (SvO2, diferença artério-venosa do conteúdo de oxigênio do sangue colhido no átrio direito e o índice cardíaco aferido pela termodiluição, com boa sensibilidade e especificidade e alto valor preditivo positivo e negativo. A pressão do sangue do átrio direito (PvO2 apresentou baixa sensibilidade na estimativa de baixo débito cardíaco. CONCLUSÃO: No pós-operatório de cirurgia cardíaca, a SvO2e a diferença artério-venosa do conteúdo de oxigênio (C(avO2 apresentaram-se como parâmetros confiáveis correlacionados a baixo débito cardíaco. A PvO2 foi pouco sensível no diagnóstico de baixo débito no pós-operatório de cirurgia cardíaca.OBJECTIVE: To determine, even during postoperative period, the confiability of the cardiac index correlate with the data data given by a central atrial venous blood gasometry in patients who underwent cardiac surgery. METHODS: From the sample of arterial and venous blood of right atrium gathered in postoperative of cardiac surgery, it was determinated the hemoglobin concentration and the gasometric study through what was observed of the venous oxygen saturation (SvO2 and the partial pressure of oxygen from venous blood gathered in right atrium (PvO2, add to the calculation of artery-venous difference of the oxygen content - radial artery / right atrium (C

  11. A case difficult to diagnose in adults: High sinus venous atrial septal defect

    Directory of Open Access Journals (Sweden)

    Ozge Cetinarslan

    2018-01-01

    Full Text Available Sinus venous atrial septal defect (SVD is highly difficult to diagnose because of its location. Below, we report a case of SVD which is misdiagnosed as pulmonary hypertension and anomalous pulmonary venous return. A 57-year-old female patient was referred to congenital disease outpatient clinic of a tertiary center. She was admitted to the hospital with complaints of fatigue and exercise dyspnea which had started a year ago. She had transthoracic echocardiography (TTE examination done in another hospital which showed dilated right heart chambers and pulmonary hypertension. She underwent transesophageal echocardiography (TEE examination with the suspicion of atrial septal defect (ASD, but no defect was seen. As her symptoms persisted, we repeated the TTE and TEE examination in our center. TEE revealed 0.6 cm ASD on the upper side of the interatrial septum. All four pulmonary veins were draining into the left atrium. Right heart catheterization (RHC confirmed the diagnosis. A left-to-right shunt was detected and localized by a significant step-up in blood oxygen saturation found between mid and upper segments of the right atrium. According to our TEE and RHC results, we planned the surgical closure of the defect. Sinus venous ASD is deficiency of the superior portion of atrial septum adjacent to superior vena cava. Diagnosis of SVD is often more difficult than other forms of ASD and may require special imaging such as TEE, magnetic resonance imaging, or computed tomographic scanning. In conclusion, cardiologists must be aware about the possibility of SVD patients who have unexplained exertional dyspnea and fatigue, dilated right atrium and ventricle, pulmonary hypertension, paradoxical embolism, or atrial arrhythmias in their respective populations.

  12. Fish Intake and Venous Thromboembolism: A Systematic Literature Review.

    Science.gov (United States)

    Mattiuzzi, Camilla; Cervellin, Gianfranco; Franchini, Massimo; Lippi, Giuseppe

    2016-05-01

    Diet plays an important role in modulating the risk of arterial and venous thrombosis. Several lines of evidence attest that consumption of fish and its compounds, especially omega-3 fatty acids, may be effective to decrease the cardiovascular risk. Since the pathogenesis of arterial and venous thrombosis share some common aspects, we performed a systematic review of published clinical studies that investigated the association between fish intake and venous thrombosis. An electronic search was carried out in Medline, Scopus, and ISI Web of Science using the key words "fish" OR "seafood" AND "venous thromboembolism" OR "deep vein thrombosis" OR "pulmonary embolism", with no language or date restriction. Overall, 6 studies (5 prospective and 1 case-control) were finally identified. In only 1 small case-control study, a larger intake of total fish was found to be negatively associated with the risk of venous thromboembolism. No association was found in 4 large prospective studies, whereas a positive association was observed in the remaining. No substantial difference was also noticed between intake of fatty or lean fish. Taken together, the current epidemiological evidence does not support the existence of a significant effect of total fish consumption on the risk of venous thromboembolism. © The Author(s) 2015.

  13. Early thrombus removal strategies for acute deep venous thrombosis: clinical practice guidelines of the Society for Vascular Surgery and the American Venous Forum.

    Science.gov (United States)

    Meissner, Mark H; Gloviczki, Peter; Comerota, Anthony J; Dalsing, Michael C; Eklof, Bo G; Gillespie, David L; Lohr, Joann M; McLafferty, Robert B; Murad, M Hassan; Padberg, Frank; Pappas, Peter; Raffetto, Joseph D; Wakefield, Thomas W

    2012-05-01

    The anticoagulant treatment of acute deep venous thrombosis (DVT) has been historically directed toward the prevention of recurrent venous thromboembolism. However, such treatment imperfectly protects against late manifestations of the postthrombotic syndrome. By restoring venous patency and preserving valvular function, early thrombus removal strategies can potentially decrease postthrombotic morbidity. A committee of experts in venous disease was charged by the Society for Vascular Surgery and the American Venous Forum to develop evidence-based practice guidelines for early thrombus removal strategies, including catheter-directed pharmacologic thrombolysis, pharmacomechanical thrombolysis, and surgical thrombectomy. Evidence-based recommendations are based on a systematic review and meta-analysis of the relevant literature, supplemented when necessary by less rigorous data. Recommendations are made according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology, incorporating the strength of the recommendation (strong: 1; weak: 2) and an evaluation of the level of the evidence (A to C). On the basis of the best evidence currently available, we recommend against routine use of the term "proximal venous thrombosis" in favor of more precise characterization of thrombi as involving the iliofemoral or femoropopliteal venous segments (Grade 1A). We further suggest the use of early thrombus removal strategies in ambulatory patients with good functional capacity and a first episode of iliofemoral DVT of venous outflow obstruction (Grade 1A). We suggest pharmacomechanical strategies over catheter-directed pharmacologic thrombolysis alone if resources are available and that surgical thrombectomy be considered if thrombolytic therapy is contraindicated (Grade 2C). Most data regarding early thrombus removal strategies are of low quality but do suggest patient-important benefits with respect to reducing postthrombotic morbidity. We

  14. Tapping but not massage enhances vasodilation and improves venous palpation of cutaneous veins.

    Science.gov (United States)

    Ichimura, Mika; Sasaki, Shinsuke; Mori, Masaharu; Ogino, Tetsuya

    2015-01-01

    This paper investigated whether tapping on the median cubital vein or massaging the forearm was more effective in obtaining better venous palpation for venipuncture. Forty healthy volunteers in their twenties were subjected to tapping (10 times in 5 sec) or massage (10 strokes in 20 sec from the wrist to the cubital fossa) under tourniquet inflation on the upper arm. Venous palpation was assessed using the venous palpation score (0-6, with 0 being impalpable). Three venous factors-venous depth, cross-sectional area, and elevation-were also measured using ultrasonography. The venous palpation score increased significantly by tapping but not by massage. Moreover, all 3 venous measurements changed significantly by tapping, while only the depth decreased significantly by massage. The three venous measurements correlated significantly with the venous palpation score, indicating that they are useful objective indicators for evaluating vasodilation. We suggest that tapping is an effective vasodilation technique.

  15. Increased venous thrombosis incidence in pregnancies after in vitro fertilization

    DEFF Research Database (Denmark)

    Hansen, Anette Tarp; Kesmodel, U S; Juul, S

    2014-01-01

    STUDY QUESTION Is venous thrombosis risk increased in pregnancies after in vitro fertilization? SUMMARY ANSWER The venous thrombosis incidence was significantly increased in pregnancies after in vitro fertilization; especially in the first trimester and in the first 6 weeks post-partum. WHAT...... IS KNOWN ALREADY In vitro fertilization without pregnancy is not associated with increased venous thrombosis incidence. STUDY DESIGN, SIZE, DURATION This national register-based cohort study covered the period from 1995 to 2005. PARTICIPANTS/MATERIALS, SETTING, METHODS All Danish pregnancies conceived...... by in vitro fertilization (n = 18 787) were included. Venous thrombosis incidence rates in pregnancies after in vitro fertilization were compared with venous thrombosis incidence rates in reference pregnancies, by calculating incidence rate ratios. MAIN RESULTS AND THE ROLE OF CHANCE In total, 48 cases were...

  16. Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.

    Science.gov (United States)

    Holly, Brian P; Steenburg, Scott D

    2011-01-01

    Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.

  17. The Current Role of Venous Sampling in the Localization of Endocrine Disease

    International Nuclear Information System (INIS)

    Lau, Jeshen H. G.; Drake, William; Matson, Matthew

    2007-01-01

    Endocrine venous sampling plays a specific role in the diagnosis of endocrine disorders. In this article, we cover inferior petrosal sinus sampling, selective parathyroid venous sampling, hepatic venous sampling with arterial stimulation, adrenal venous sampling, and ovarian venous sampling. We review their indications and the scientific evidence justifying these indications in the diagnosis and management of Cushing's syndrome, hyperparathyroidism, pancreatic endocrine tumors, Conn's syndrome, primary hyperaldosteronism, pheochromocytomas, and androgen-secreting ovarian tumors. For each sampling technique, we compare its diagnostic accuracy with that of other imaging techniques and, where possible, look at how it impacts patient management. Finally, we incorporate venous sampling into diagnostic algorithms used at our institution

  18. Deep venous thrombosis and postthrombotic syndrome: invasive management.

    Science.gov (United States)

    Comerota, A J

    2015-03-01

    Invasive management of postthrombotic syndrome encompasses the two ends of the deep vein thrombosis spectrum, patients with acute iliofemoral deep vein thrombosis and those with chronic postthrombotic iliofemoral venous obstruction. Of all patients with acute deep vein thrombosis, those with involvement of the iliofemoral segments have the most severe chronic postthrombotic morbidity. Catheter-based techniques now permit percutaneous treatment to eliminate thrombus, restore patency, potentially maintain valvular function, and improve quality of life. Randomized trial data support an initial treatment strategy of thrombus removal. Failure to eliminate acute thrombus from the iliofemoral system leads to chronic postthrombotic obstruction of venous outflow. Debilitating chronic postthrombotic symptoms of the long-standing obstruction of venous outflow can be reduced by restoring unobstructed venous drainage from the profunda femoris vein to the vena cava. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. Anticoagulation period in idiopathic venous thromboembolism

    International Nuclear Information System (INIS)

    Farraj, Rami S.

    2004-01-01

    The period of anticoagulation of a first episode of idiopathic venous thromboembolism has been 6 months. It is unclear if such patients would benefit from longer treatment, as there appears to be an increased risk of recurrence after anticoagulation is stopped. In a randomized prospective study of 64 patients admitted to King Hussein Medical city, Amman, Jordan, who developed a first episode of venous thromboembolism, 32 patients were given warfarin for 24-months, while 32 patients stopped anticoagulation after completion of 6-months of therapy. Our goal was to determine the effects of extended anticoagulation on rates of recurrence of symptomatic venous thromboembolism and bleeding. The patients were followed for 12-months after stopping anticoagulation. After 24-months, 7 of the 32 patients (21%) who had standard anticoagulation for 6-months had a recurrent episode of thromboembolism compared to one of the 32 patients who received anticoagulation for 24 months (3%). Extended warfarin therapy for 24-months has resulted in an absolute risk reduction of 0.1% (p<0.05). This translates into 8 patients having to be treated for 24-months to avoid one recurrence without increasing the risk of major bleeding. Two patients in each group (6%) had major nonfatal bleeding, all 4 bleeding episodes occurring within the first 3-months of anticoagulation. After 36-months of follow up, the recurrence rate of extended warfarin therapy was only 3 patients (9%), which is a 43% relative reduction in recurrence of thromboembolism compared to standard therapy for 6-months. Patients with first episodes of idiopathic venous thromboembolism have an increased risk of recurrent venous thromboembolism and should be treated with oral anticoagulants for longer than 6-months, probably 24-months. (author)

  20. Arterial stick

    Science.gov (United States)

    ... be some throbbing. Why the Test Is Performed Blood transports oxygen, nutrients, waste products, and other materials within ... venous blood) mainly in its content of dissolved gases . Testing arterial blood shows the makeup of the blood before any ...

  1. Traumatic dural venous sinus thrombosis: A Mini Review

    Directory of Open Access Journals (Sweden)

    Moscote-Salazar Luis Rafael

    2016-09-01

    Full Text Available The dural venous sinus thrombosis is a benign disease, representing about 1% of cerebral vascular events. In some cases the development of the disease increased intracranial pressure or symptomatic epilepsy. The development towards a dural venous sinus thrombosis is rare, but is a condition to be considered before the development of ischemic vascular events and a history of recent head trauma. Intracranial hematomas or skull fractures can lead to the establishment of obstructive pathology of the dural venous sinuses. The knowledge of this entity is necessary for the critical care staff and neurosurgery staff.

  2. Developmental venous anomalies with capillary stain: a subgroup of symptomatic DVAs?

    NARCIS (Netherlands)

    Roccatagliata, Luca; van den Berg, René; Soderman, Michael; Boulin, Anne; Condette-Auliac, Stéphanie; Rodesch, Georges

    2012-01-01

    Intracranial developmental venous anomalies (DVAs) are considered benign vascular dispositions; they are asymptomatic in the vast majority of cases. They represent extreme variations of the venous drainage and may rarely be responsible for focal venous ischemia leading to neurological dysfunction.

  3. Effect of exercise therapy on lower extremity deep venous thrombosis after total knee arthoplasty

    Directory of Open Access Journals (Sweden)

    Zhong-Wu Huang

    2016-11-01

    Full Text Available Objective: To explore the effect of exercise therapy in preventing the lower extremity deep venous thrombosis (DVT after total knee arthoplasty (TKA. Methods: A total of 153 patients with osteoarthritis who were admitted in our hospital for TKA were included in the study and randomized into the observation group and the control group. The patients in the observation group were given continuous passive motion (CPM in combined with exercise therapy, while the patients in the control group were only given CPM. After 2-week treatment, the related coagulation indicators and femoral venous blood flow in the two groups were detected and compared. The occurrence rate of DVT in the two groups was calculated. Results: PT and APTT from 2 weeks to 2 months after operation in the two groups were shortened first and extended later when compared with before operation, while FIB and D-D contents were elevated first and reduced later, and the coagulation indicator levels 2 months after treatment in the two groups were significantly different from those before operation. The femoral venous blood flow peak and average velocity 1 week after operation in the two groups were significantly elevated when compared with before operation. The femoral venous blood flow peak and average velocity 1 week after operation in the observation group were significantly higher than those in the control group. The occurrence rate of DVT in the observation group was significantly lower than that in the control group. Conclusions: CPM in combined with exercise therapy for patients after TKA can effectively prevent the formation of DVT, with a significant effect.

  4. Effects of oxygen content and heating rate on phase transition behavior in Bi2(V0.95Ti0.05)O5.475-x

    International Nuclear Information System (INIS)

    Taninouchi, Yu-ki; Uda, Tetsuya; Ichitsubo, Tetsu; Awakura, Yasuhiro; Matsubara, Eiichiro

    2011-01-01

    Highlights: → Phase transition behavior of oxide-ion conductor Bi 2 (V 0.95 Ti 0.05 )O 5.475-x , which has various thermal histories and physical forms. → At the same heating rate of 10 K min -1 , Bi 2 (V 0.95 Ti 0.05 )O 5.475-x with less oxygen content exhibits transition from α f to β f at a higher temperature and the transition from β f to γ f at a lower temperature. → α f directly transformed to β f at fast heating rates. At a slower heating rate of 2 K min -1 , β f precipitated from α f due to the sufficient diffusion of Ti and oxygen vacancies. - Abstract: The phase transition behavior of oxide-ion conductor Bi 2 (V 0.95 Ti 0.05 )O 5.475-x , which has various thermal histories and sample forms, has been studied by means of differential scanning calorimetry. Thermogravimetric analysis revealed that the oxygen content per compositional formula varied with the applied thermal treatment, although no significant structural difference was observed by X-ray diffraction (XRD) analysis. The phase transition behavior from α f to β f and from β f to γ f , observed at a heating rate of 10 K min -1 , are markedly affected by the sample preparation. For example, the endothermic peak of the transition from α f to β f appeared at around 400 deg. C for quenched powder and at around 320 deg. C for powder cooled at 0.5 K min -1 . The trend of the transition temperatures can be qualitatively explained in terms of oxygen content, i.e., Bi 2 (V 0.95 Ti 0.05 )O 5.475-x with less oxygen content exhibits the transition from α f to β f at a higher temperature and the transition from β f to γ f at a lower temperature. We confirmed the two types of transition behavior from α f to β f depending on heating rate of DSC and high-temperature X-ray diffraction (HT-XRD) analysis. At rapid heating rates of 10 and 40 K min -1 , α f transformed to β f directly. Meanwhile, at a slow heating rate of 2 K min -1 , the β f precipitated from α f because slow heating

  5. Arterial versus venous lactate: a measure of sepsis in children.

    Science.gov (United States)

    Samaraweera, Sahan Asela; Gibbons, Berwyck; Gour, Anami; Sedgwick, Philip

    2017-08-01

    This study assessed the agreement between arterial and venous blood lactate and pH levels in children with sepsis. This retrospective, three-year study involved 60 PICU patients, with data collected from electronic or paper patient records. The inclusion criteria comprised of children (≤17 years old) with sepsis and those who had a venous blood gas taken first with an arterial blood gas taken after within one hour. The lactate and pH values measured through each method were analysed. There is close agreement between venous and arterial lactate up to 2 mmol/L. As this value increases, this agreement becomes poor. The limits of agreement (LOA) are too large (±1.90 mmol/L) to allow venous and arterial lactate to be used interchangeably. The mean difference and LOA between both methods would be much smaller if derived using lactate values under 2.0 mmol/L. There is close agreement between arterial and venous pH (MD = -0.056, LOA ± 0.121). However, due to extreme variations in pH readings during sepsis, pH alone is an inadequate marker. A venous lactate ≤2 mmol/L can be used as a surrogate for arterial lactate during early management of sepsis in children. However, if the value exceeds 2 mmol/L, an arterial sample must confirm the venous result. What is known: • In children with septic shock, a blood gas is an important test to show the presence of acidosis and high lactic acid. Hyperlactataemia on admission is an early predictor of outcome and is associated with a greater mortality risk. • An arterial sample is the standard for lactate measurement, however getting a sample may be challenging in the emergency department or a general paediatric ward. Venous samples are quicker and easier to obtain. Adult studies generally advise caution in replacing venous lactate values for the arterial standard, whilst paediatric studies are limited in this area. What is new: • This is the first study assessing the agreement between arterial and peripheral venous

  6. Evaluation of treatment with carboxymethylcellulose on chronic venous ulcers*

    Science.gov (United States)

    Januário, Virginia; de Ávila, Dione Augusto; Penetra, Maria Alice; Sampaio, Ana Luisa Bittencourt; Noronha Neta, Maria Isabel; Cassia, Flavia de Freire; Carneiro, Sueli

    2016-01-01

    BACKGROUND: Among the chronic leg ulcers, venous ulcers are the most common and constitute a major burden to public health. Despite all technology available, some patients do not respond to established treatments. In our study, carboxymethylcellulose was tested in the treatment of refractory chronic venous ulcers. OBJECTIVE: To evaluate the efficacy of carboxymethylcellulose 20% on the healing of chronic venous ulcers refractory to conventional treatments. METHODS: This is an analytical, pre-experimental study. Thirty patients were included with refractory venous ulcers, and applied dressings with carboxymethylcellulose 20% for 20 weeks. The analysis was based on measurement of the area of ulcers, performed at the first visit and after the end of the treatment. RESULTS: There was a reduction of 3.9 cm2 of lesion area (p=0.0001), corresponding to 38.8% (p=0.0001). There was no interruption of treatment and no increase in lesion area in any patient. CONCLUSIONS: Carboxymethylcellulose 20% represents a low cost and effective therapeutic alternative for the treatment of refractory chronic venous ulcers. However, controlled studies are necessary to prove its efficacy. PMID:26982773

  7. Counteracting venous stasis during acute lower leg immobilization.

    NARCIS (Netherlands)

    Poelkens, F.; Thijssen, D.H.J.; Kersten, B.T.P.; Scheurwater, H.; Laarhoven, E.W. van; Hopman, M.T.E.

    2006-01-01

    AIM: During lower limb immobilization, patients are at risk to develop deep venous thrombosis. Recently, a water-pad was developed that should counteract venous stasis. The water-pad, located under the plaster, mobilizes water from the foot to the calf during weight bearing and, thereby, imitates

  8. Effect of Zr Purity and Oxygen Content on the Structure and Mechanical Properties of Melt-Spun and Suction-Cast Cu46Zr42Al7Y5 Alloy

    Directory of Open Access Journals (Sweden)

    Kozieł T.

    2016-06-01

    Full Text Available The effect of oxygen content in zirconium on the structure and mechanical properties of the Cu46Zr42Al7Y5 alloy, in the form of melt-spun ribbons and suction-cast rods, was investigated. Two types of Zr, rod and crystal bar of different nominal purities and oxygen contents, were used to synthesize the alloy by arc melting. Rapidly solidified ribbons were produced by melt spinning and their amorphous structures were confirmed by X-ray diffractometry (XRD and differential scanning calorimetry (DSC. Bulk samples in the form of rods were cast using a special water-cooled suction casting unit attached to the arc melting system. XRD and DSC studies proved the amorphous structure of the bulk alloy synthesized from low-oxygen Zr and partial crystallization of the same alloy for high-oxygen Zr. In both bulk samples, uniformly distributed crystalline particles were identified as yttrium oxides. Higher mean compressive strength of amorphous alloy was observed. The hardness of amorphous phase was close to 500 HV1 in both bulk alloys, while the hardness of crystalline dendritic areas, observed in the alloy synthesized from high oxygen Zr, was lower by about 50 HV1.

  9. Pediatric central venous access devices: nursing interventions

    Directory of Open Access Journals (Sweden)

    Duffy EA

    2017-05-01

    Full Text Available Elizabeth A Duffy, Kathryn N Nelson Department of Health Behavior and Biological Sciences, The University of Michigan School of Nursing, Ann Arbor, MI, USA Abstract: A central venous catheter (CVC is an indwelling catheter that provides permanent or temporary stable venous access for both acute and chronically ill pediatric patients. These catheters provide stable venous access that can be used for a variety of medical purposes including drawing blood, hemodynamic monitoring, infusion of intravenous medications, infusion of intravenous fluids, chemotherapy, blood products, and parenteral nutrition. Each day, nurses access and care for CVCs in infants, children, and adolescents; the precision of this care can prevent life-threatening complications. The purpose of this review and the case study is to highlight the importance and components of evidence-based nursing practice in pediatric CVC care. A historical perspective of CVC care is provided in conjunction with current national initiatives to improve patient outcomes for children with CVCs. Infection prevention, clinical practice guidelines, quality improvement, and evidence-based care bundles are discussed. Keywords: pediatric nursing, central venous catheters, central line-associated bloodstream infection, care bundles, pediatric case study 

  10. Radiological evaluation of the chronic venous stasis syndrome

    International Nuclear Information System (INIS)

    Train, J.S.; Schanzer, H.; Peirce, E.C. II; Dan, S.J.; Mitty, H.A.

    1987-01-01

    Chronic venous stasis is an extremely complex clinical syndrome of pain and changes in the skin that can involve the superficial, deep, and perforating veins. This syndrome is commonly referred to as the postphlebitic syndrome, implying that thrombophlebitis is its sole etiology. To test this hypothesis, the authors performed ascending venography on 51 limbs of patients with the chromic venous stasis syndrome and demonstrated that 32 had no radiological evidence of recent or old thrombophlebitis. Instead, they had normal-appearing veins, suggesting primary incompetence of the deep and/or perforating venous valves rather than thrombophlebitis as the etiology. Since various operations have recently been proposed to correct or bypass malfunctioning valves, precise demonstration of pathological change is required to choose the appropriate procedure and to evaluate results. Descending venograms were combined with the ascending studies in 42 limbs for this purpose. In addition to outlining the abnormalities responsible for chronic venous stasis syndrome in individual cases, interesting conclusions regarding the syndrome itself were reached

  11. Inner Retinal Oxygen Delivery, Metabolism, and Extraction Fraction in Ins2Akita Diabetic Mice.

    Science.gov (United States)

    Blair, Norman P; Wanek, Justin; Felder, Anthony E; Brewer, Katherine C; Joslin, Charlotte E; Shahidi, Mahnaz

    2016-11-01

    Retinal nonperfusion and hypoxia are important factors in human diabetic retinopathy, and these presumably inhibit energy production and lead to cell death. The purpose of this study was to elucidate the effect of diabetes on inner retinal oxygen delivery and metabolism in a mouse model of diabetes. Phosphorescence lifetime and blood flow imaging were performed in spontaneously diabetic Ins2Akita (n = 22) and nondiabetic (n = 22) mice at 12 and 24 weeks of age to measure retinal arterial (O2A) and venous (O2V) oxygen contents and total retinal blood flow (F). Inner retinal oxygen delivery (DO2) and metabolism (MO2) were calculated as F ∗ O2A and F ∗ (O2A - O2V), respectively. Oxygen extraction fraction (OEF), which equals MO2/DO2, was calculated. DO2 at 12 weeks were 112 ± 40 and 97 ± 29 nL O2/min in nondiabetic and diabetic mice, respectively (NS), and 148 ± 31 and 85 ± 37 nL O2/min at 24 weeks, respectively (P < 0.001). MO2 were 65 ± 31 and 66 ± 27 nL O2/min in nondiabetic and diabetic mice at 12 weeks, respectively, and 79 ± 14 and 54 ± 28 nL O2/min at 24 weeks, respectively (main effects = NS). At 12 weeks OEF were 0.57 ± 0.17 and 0.67 ± 0.09 in nondiabetic and diabetic mice, respectively, and 0.54 ± 0.07 and 0.63 ± 0.08 at 24 weeks, respectively (main effect of diabetes: P < 0.01). Inner retinal MO2 was maintained in diabetic Akita mice indicating that elevation of the OEF adequately compensated for reduced DO2 and prevented oxidative metabolism from being limited by hypoxia.

  12. Metastatic Carcinoma of Unknown Primary Presenting as Jugular Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Prince Cheriyan Modayil

    2009-01-01

    Full Text Available Jugular venous thrombosis is unusual and is associated with central venous catheterisation, intravenous drug abuse and head and neck sepsis. It is rarely associated with malignancy. We report a case of metastatic carcinoma of unknown primary in a forty year old female which presented with jugular venous thrombosis. The discussion includes investigation and treatment options for this condition.

  13. Oxygen and disorder effect in the magnetic properties of manganite films

    Energy Technology Data Exchange (ETDEWEB)

    Sirena, M. E-mail: sirenam@ib.cnea.gov.ar; Haberkorn, N.; Granada, M.; Steren, L.B.; Guimpel, J

    2004-05-01

    We have made a systematic study of the magnetic properties of low doped manganite films submitted to different oxygenation treatments. We have found that oxygenation dynamics depends critically of the strain field in the sample. The T{sub C} and the Mr increase as the oxygen content is increased. A decrease of the coercive field of the LSMO-STO films was observed, indicating that annealing treatments increase the oxygen content reducing oxygen vacancies.

  14. Oxygen and disorder effect in the magnetic properties of manganite films

    International Nuclear Information System (INIS)

    Sirena, M.; Haberkorn, N.; Granada, M.; Steren, L.B.; Guimpel, J.

    2004-01-01

    We have made a systematic study of the magnetic properties of low doped manganite films submitted to different oxygenation treatments. We have found that oxygenation dynamics depends critically of the strain field in the sample. The T C and the Mr increase as the oxygen content is increased. A decrease of the coercive field of the LSMO-STO films was observed, indicating that annealing treatments increase the oxygen content reducing oxygen vacancies

  15. An unusual cause of hydrocephalus: aqueductal developmental venous anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Yagmurlu, Banu; Fitoz, Suat; Atasoy, Cetin; Erden, ilhan [Ankara University School of Medicine, Department of Radiology, Ankara (Turkey); Deda, Gulhis; Unal, Ozlem [Ankara University School of Medicine, Division of Pediatric Neurology, Ankara (Turkey)

    2005-06-01

    Vascular malformations are infrequent causes of aqueductal stenoses, developmental venous anomaly (DVA) being the rarest among them. DVAs, also known as venous angiomas, are congenital in origin and characterized by dilatation of vessels in the superficial and deep venous system. Although they are usually clinically silent, they can be complicated by hemorrhage, seizures and neurologic deficits. Herein, we report MR imaging findings of a 7-year-old girl whose hydrocephalus was due to an abnormal vein coursing through the aqueduct. (orig.)

  16. How to objectively assess jugular primary venous obstruction

    Directory of Open Access Journals (Sweden)

    Paolo Zamboni

    2014-12-01

    Full Text Available Last January The Lancet published the article by Traboulsee et al. Prevalence of extracranial venous narrowing on catheter venography in people with multiple sclerosis, their sibilings, and unrelated healthy controls: a blinded, case control study. These Authors confirmed the presence of chronic cerebrospinal venous insufficiency with a high prevalence of about 70% in the Canadian population, but without significant differences between patients and healthy controls, yet. However, they used a criterion never published to assess stenosis, in alternative to the classic measurement of the diameter in the segment immediately preceding the narrowest point. Traboulsee et al. measure the stenosis along the entire length of the internal jugular vein, by comparing the maximum diameter with the narrowest point. It has been demonstrated, from normal anatomy findings, how the jugular bulb diameter normally exceeds 50% of the minimum diameter of the internal jugular vein, clearly showing the reason why Traboulsee et al. did not find significant differences between people with multiple sclerosis, their sibilings, and unrelated healthy controls. Furthermore, as the outcome measure of Traboulsee et al., wall stenosis is a neglected part of primary venous obstruction, because in the majority of cases obstruction is the consequence of intraluminal obstacles, as a considerable part of truncular venous malformations, and/or compression; rarely of external hypoplasia. Finally, several recently published methods can be adopted for objective assessment of restricted jugular flow in course of chronic cerebrospinal venous insufficiency, by the means of non invasive magnetic resonance imaging, ultrasound and plethysmography. This may help us in improving the assessment of cerebral venous return in the near future.

  17. [Venous thrombosis of atypical location in patients with cancer].

    Science.gov (United States)

    Campos Balea, Begoña; Sáenz de Miera Rodríguez, Andrea; Antolín Novoa, Silvia; Quindós Varela, María; Barón Duarte, Francisco; López López, Rafael

    2015-01-01

    Venous thromboembolism (VTE) is a complication that frequently occurs in patients with neoplastic diseases. Several models have therefore been developed to identify patient subgroups diagnosed with cancer who are at increased risk of developing VTE. The most common forms of thromboembolic episodes are deep vein thrombosis in the lower limbs and pulmonary thromboembolism. However, venous thrombosis is also diagnosed in atypical locations. There are few revisions of unusual cases of venous thrombosis. In most cases, VTE occurs in the upper limbs and in the presence of central venous catheters, pacemakers and defibrillators. We present the case of a patient diagnosed with breast cancer and treated with surgery, chemotherapy and radiation therapy who developed a thrombosis in the upper limbs (brachial and axillary). Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  18. A role for haemolymph oxygen capacity in heat tolerance of eurythermal crabs.

    Directory of Open Access Journals (Sweden)

    Folco eGiomi

    2013-05-01

    Full Text Available Heat tolerance in aquatic ectotherms is constrained by a mismatch, occurring at high temperatures, between oxygen delivery and demand which compromises the maintenance of aerobic scope. The present study analyses how the wide thermal tolerance range of an eurythermal model species, the green crab Carcinus maenas is supported and limited by its ability to sustain efficient oxygen transport to tissues. Similar to other eurytherms, C. maenas sustains naturally occurring acute warming events through the integrated response of circulatory and respiratory systems. The response of C. maenas to warming is characterized by two phases. During initial warming, oxygen consumption and heart rate increase while stroke volume and haemolymph oxygen partial pressures decrease. During further warming, dissolved oxygen levels in the venous compartment decrease below the threshold of full haemocyanin oxygen saturation. The progressive release of haemocyanin bound oxygen with further warming follows an exponential pattern, thereby saving energy in oxygen transport and causing an associated leveling off of metabolic rate. According to the concept of oxygen and capacity limited thermal tolerance, this indicates that the thermal tolerance window is widened by the increasing contribution of haemocyanin oxygen transport and associated energy savings in cardiocirculation. Haemocyanin bound oxygen sustains cardiac performance to cover the temperature range experienced by C. maenas in the field. To our knowledge this is the first study providing evidence of a relationship between thermal tolerance and blood (haemolymph oxygen transport in eurythermal invertebrates.

  19. A role for haemolymph oxygen capacity in heat tolerance of eurythermal crabs.

    Science.gov (United States)

    Giomi, Folco; Pörtner, Hans-Otto

    2013-01-01

    Heat tolerance in aquatic ectotherms is constrained by a mismatch, occurring at high temperatures, between oxygen delivery and demand which compromises the maintenance of aerobic scope. The present study analyses how the wide thermal tolerance range of an eurythermal model species, the green crab Carcinus maenas is supported and limited by its ability to sustain efficient oxygen transport to tissues. Similar to other eurytherms, C. maenas sustains naturally occurring acute warming events through the integrated response of circulatory and respiratory systems. The response of C. maenas to warming can be characterized by two phases. During initial warming, oxygen consumption and heart rate increase, while stroke volume and haemolymph oxygen partial pressure decrease. During further warming, dissolved oxygen levels in the venous compartment decrease below the threshold of full haemocyanin oxygen saturation. The progressive release of haemocyanin bound oxygen with further warming follows an exponential pattern, thereby saving energy in oxygen transport and causing an associated leveling off of metabolic rate. According to the concept of oxygen and capacity limited thermal tolerance (OCLTT), this indicates that the thermal tolerance window is widened by the increasing contribution of haemocyanin oxygen transport and associated energy savings in cardiocirculation. Haemocyanin bound oxygen sustains cardiac performance to cover the temperature range experienced by C. maenas in the field. To our knowledge this is the first study providing evidence of a relationship between thermal tolerance and blood (haemolymph) oxygen transport in a eurythermal invertebrate.

  20. Oxygen delivery and consumption during on-bypass cabg in htea and central analgesia

    Directory of Open Access Journals (Sweden)

    Віталій Олексійович Собокарь

    2015-04-01

    Full Text Available Objective. Despite some advantages, the use of high thoracic epidural anesthesia (HTEA during on-bypass cardiac surgery may be discouraged by fear of adverse hemodynamic effects and associated disturbances of oxygen delivery.Aim. To compare oxygen delivery and consumption during on-bypass coronary artery bypass grafting in settings of HTEA and central analgesia (CA.Methods. 132 patients were assigned into two groups – study group (n=85, where the surgery was performed under HTEA and control group (n=47 - where the surgery was carried out under CA. Using data of transesophageal cardiac ultrasound and blood oximetry blood oxygen delivery (DO2, oxygen consumption (VO2, oxygen extraction coefficient (CEO2 were calculated at four stages of the surgery: after induction, sternotomy, cardiopulmonary bypass and at the end of the surgery.Results. In the initial stages of the surgery DO2 and VO2 were reduced relative to reference values with a tendency to increase in the course of the operation and achievement of the normal or supernormal level (VO2, study group in the final stage. The decrease was due to moderate hypodynamic circulation and hemodilution. After sternotomy DO2 in the study group was higher than that of the control: 356 (279; 458 vs 317±89 ml·min-1·m-2, (р=0,021. After cardiopulmonary bypass oxygen saturation of venous blood (SatvO2, in the study group was 71 ± 9 % compared with 68 ± 10 % in the control group. At the end of the surgery SatvO2 in the study group was 71 (66; 75 vs 59 (53; 70 % in the control (р = 0,005 and oxygen tension of venous blood (РvО2 was correspondingly 39 ± 6 and 33 (30; 38 mm Hg (р = 0,027. Despite the decrease in DO2 and VO2, oxygen extraction indices - CEO2, pvO2, SatvO2, and remained within the reference range, except that of the control group at the end of the surgery. Furthermore, at no stage lactate rise or acid-base deviations was observed in the both groups.Conclusions. In patients operated

  1. [Peroxynitrite effect on the haemoglobin oxygen affinity in vitro in presence of different partial pressure of carbon dioxide].

    Science.gov (United States)

    Stepuro, T L; Zinchuk, V V

    2011-08-01

    Peroxynitrite (ONOO-) besides its toxic possesses regulatory action that includes the modulation of oxygen binding properties of blood. The aim of this work was to estimate ONOO- effect on the haemoglobin oxygen affinity (HOA) in vitro in presence of different partial pressure of carbon dioxide (CO2). The ONOO- presence in venous blood in conditions of hypercapnia induced oxyhaemoglobin dissociation curve shift leftward while in hypocapnic conditions the result of a different character was obtained. The revealed effect of ONOO- is realized, possibly, through various modifications ofhaemoglobin whose formation is dependent on the CO2 pressure. The ONOO- influences the HOA in different manner that can be important in regulation of blood oxygenation in lungs and maintenance of oxygen consumption in tissues.

  2. Venous Thromboembolism in Podiatric Foot and Ankle Surgery.

    Science.gov (United States)

    Matthews, Jemma H; Terrill, Alexander J; Barwick, Alex L; Butterworth, Paul A

    2018-01-01

    The extent to which podiatric surgeons follow venous thromboembolism guidelines is unknown. The aim of this study therefore, was 2-fold: (a) to determine the rate of venous thromboembolism following podiatric surgery and (b) to investigate the factors that influence the use of thromboprophylaxis. Data from 4238 patients who underwent foot and ankle surgery over 2 years were analyzed. Venous thromboembolism within the first 30 days following surgery was recorded using the Australasian College of Podiatric Surgeons surgical audit tool. Logistic regression analyses were undertaken to determine the factors that influenced thromboprophylaxis. Of the 4238 patient records, 3677 records (87%) provided complete data (age range 2-94 years; mean ± SD, 49.1 ± 19.7 years; 2693 females). A total of 7 venous thromboembolic events (0.2% rate) were reported. Operative duration and age (OR 12.63, 95% CI 9.47 to 16.84, P < 0.01), postoperative immobilization (OR 6.94, 95% CI 3.95 to 12.20, P < 0.01), and a prior history of VTE (OR 3.41, 95% CI 1.01 to 11.04, P = 0.04) were the strongest predictors of thromboprophylaxis. Podiatric foot and ankle surgery is associated with a low rate of venous thromboembolism. This may be due in part to the thromboprophylaxis regime implemented by podiatric surgeons, which closely aligns with current evidence-based guidelines. Level II: Prospective cohort study.

  3. Severe Juxtahepatic Venous Injury: Survival after Prolonged Hepatic Vascular Isolation Without Shunting

    Directory of Open Access Journals (Sweden)

    J. E. J. Krige

    1990-01-01

    Full Text Available Survival following major juxtahepatic venous injury is rare in blunt liver trauma despite the use of intracaval shunting. Prolonged liver arterial inflow control, total hepatic venous isolation and lobectomy without shunting was used in a patient to repair a combined vena caval and hepatic venous injury after blunt liver injury. An extended period of normothermic hepatic ischemia was tolerated. Early recognition of retrohepatic venous injury and temporary liver packing to control bleeding and correct hypovolemia are essential before caval occlusion. Hepatic vascular isolation without shunting is an effective simple alternative technique allowing major venous repair in complex liver trauma.

  4. Visualization of coronary venous anatomy by cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Crean Andrew

    2009-08-01

    Full Text Available Abstract Background Coronary venous imaging with whole-heart cardiovascular magnetic resonance (CMR angiography has recently been described using developmental pulse sequences and intravascular contrast agents. However, the practical utility of coronary venous imaging will be for patients with heart failure in whom cardiac resynchronisation therapy (CRT is being considered. As such complementary information on ventricular function and myocardial viability will be required. The aim of this study was to determine if the coronary venous anatomy could be depicted as part of a comprehensive CMR protocol and using a standard extracellular contrast agent. Methods and Results Thirty-one 3D whole heart CMR studies, performed after intravenous administration of 0.05 mmol/kg gadolinium DTPA, were reviewed. The cardiac venous system was visualized in all patients. The lateral vein of the left ventricle was present in 74%, the anterior interventricular vein in 65%, and the posterior interventricular vein in 74% of patients. The mean maximum distance of demonstrable cardiac vein on the 3D images was 81.5 mm and was dependent on the quality of the 3D data set. Five patients showed evidence of myocardial infarction on late gadolinium enhancement (LGE images. Conclusion Coronary venous anatomy can be reliably demonstrated using a comprehensive CMR protocol and a standard extracellular contrast agent. The combination of coronary venous imaging, assessment of ventricular function and LGE may be useful in the management of patients with LV dysfunction being considered for CRT.

  5. [Extracorporeal gas exchange--an alternative to ventilation of the premature newborn infant with respiratory insufficiency].

    Science.gov (United States)

    Schmidt, S; Dudenhausen, J W; Langner, K; Laiblin, C; Saling, E

    1984-01-01

    In spite of improvements in its prophylaxis and therapy the membrane syndrome is still one of the main causes of morbidity and mortality in newborns. In many perinatal centers in the United States extracorporeal gas exchange via an artificial lung is the ultimate step in therapy for this group of patients today. As a result of our own research work we are able to introduce an extracorporeal circulation system which is especially suited to the particular situation of the immature newborn and which enables a complete immobilization of the lung to avoid baro-trauma with alveolar oxygen diffusion and CO2-removal through the membrane lung. Using appropriate dimensions the system can be housed in a newborn incubator. With low total resistance the perfusion in the newborn is performed via an arterio-venous shunt of the umbilical vessels alternatively with and without a mechanical pump. We tested this perfusion system on premature lambs with a gestational age of 128 to 130 days. During a test period of from 6 to 8 hours at a low blood flow rate (200 ml/min) we achieved a sufficient CO2-removal via the membrane lung with enough oxygen supply through the non-ventilated lung. By means of suitable materials, and using CO2 gas priming procedure and employing prostacyclin analogons to inhibit thrombocyte aggregation, it was possible to lower the heparine dosage to a minimum.

  6. Admission Hyperglycemia and Clinical Outcome in Cerebral Venous Thrombosis

    NARCIS (Netherlands)

    Zuurbier, Susanna M.; Hiltunen, Sini; Tatlisumak, Turgut; Peters, Guusje M.; Silvis, Suzanne M.; Haapaniemi, Elena; Kruyt, Nyika D.; Putaala, Jukka; Coutinho, Jonathan M.

    2016-01-01

    Background and Purpose-Admission hyperglycemia is associated with poor clinical outcome in ischemic and hemorrhagic stroke. Admission hyperglycemia has not been investigated in patients with cerebral venous thrombosis. Methods-Consecutive adult patients with cerebral venous thrombosis were included

  7. Synthesis of Graphite Oxide with Different Surface Oxygen Contents Assisted Microwave Radiation

    Directory of Open Access Journals (Sweden)

    Adriana Ibarra-Hernández

    2018-02-01

    Full Text Available Graphite oxide is synthesized via oxidation reaction using oxidant compounds that have lattice defects by the incorporation of unlike functional groups. Herein, we report the synthesis of the graphite oxide with diverse surface oxygen content through three (B, C, D different modified versions of the Hummers method assisted microwave radiation compared with the conventional graphite oxide sample obtained by Hummers method (A. These methods allow not only the production of graphite oxide but also reduced graphene oxide, without undergoing chemical, thermal, or mechanical reduction steps. The values obtained of C/O ratio were ~2, 3.4, and ~8.5 for methodologies C, B, and D, respectively, indicating the presence of graphite oxide and reduced graphene oxide, according to X-ray photoelectron spectroscopy. Raman spectroscopy of method D shows the fewest structural defects compared to the other methodologies. The results obtained suggest that the permanganate ion produces reducing species during graphite oxidation. The generation of these species is attributed to a reversible reaction between the permanganate ion with π electrons, ions, and radicals produced after treatment with microwave radiation.

  8. Oxygen content modulation by nanoscale chemical and electrical patterning in epitaxial SrCoO3-δ (0 < δ ≤ 0.5) thin films

    Science.gov (United States)

    Hu, S.; Seidel, J.

    2016-08-01

    Fast controllable redox reactions in solid materials at room temperature are a promising strategy for enhancing the overall performance and lifetime of many energy technology materials and devices. Easy control of oxygen content is a key concept for the realisation of fast catalysis and bulk diffusion at room temperature. Here, high quality epitaxial brownmillerite SrCoO2.5 thin films have been oxidised to perovskite (P) SrCoO3 with NaClO. X-ray diffraction, scanning probe microscopy and x-ray photoelectron spectroscopy measurements were performed to investigate the structural and electronic changes of the material. The oxidised thin films were found to exhibit distinct morphological changes from an atomically flat terrace structure to forming small nanosized islands with boundaries preferentially in [100] or [010] directions all over the surface, relaxing the in-plane strain imposed by the substrate. The conductivity, or oxygen content, of each single island is confined by these textures, which can be locally patterned even further with electric poling. The high charging level at the island boundaries indicates a magnified electric capacity of SCO thin films, which could be exploited in future device geometries. This finding represents a new way of oxygen modulation with associated self-assembled charge confinement to nanoscale boundaries, offering interesting prospects in nanotechnology applications.

  9. Color-flow Doppler imaging in suspected extremity venous thrombosis

    International Nuclear Information System (INIS)

    Foley, W.D.; Middleton, W.D.; Lawson, T.L.; Hinson, G.W.; Puller, D.R.

    1987-01-01

    Color-flow Doppler imaging (CFDI) (Quanatum, 5 and 7.5 MHz, linear array) has been performed on 23 extremities (nine positive for venous thrombosis, 14 negative) with venographic correlation. CFDI criteria evaluated were venous color-flow respiratory variation, augmentation, compressibility, valve competence, and intraluminal echogenic filling defects. Both CFDI and venography were evaluated independently and prospectively. CFDI and venography agreed in all six cases of femoral vein thrombosis and eight of nine cases of popliteal vein thrombosis. CFDI was negative in one instance of recanalized popliteal vein thrombosis. Recanalized femoral vein thrombosis was documented in three patients by CFDI when the vein was nonopacified on conventional venography. CFDI provides a rapid and accurate assessment of the femoral popliteal venous system and can distinguish an occluded from a recanalized thrombus. Initial experience with auxiliary subclavian venous thrombus has produced equally accurate results

  10. Idiopathic versus secondary venous thromboembolism. Findings of the RIETE registry.

    Science.gov (United States)

    Pedrajas, J M; Garmendia, C; Portillo, J; Gabriel, F; Mainez, C; Yera, C; Monreal, M

    2014-10-01

    The Computerized Registry of Patients with Venous Thromboembolism (RIETE) is a prospective registry that consecutively includes patients diagnosed with venous thromboembolism. We compared the clinical presentation and response to anticoagulant treatment in patients with idiopathic venous thromboembolism (IVT) versus secondary venous thromboembolism (SVT, associated with a risk factor). We analyzed the differences in clinical characteristics, comorbidity, treatment and events during the first 3months after the diagnosis of venous thromboembolism in patients with IVT or SVT and according to their initial clinical presentation. A total of 39,921 patients with IVT (n=18,029; 45.1%) or SVT (n=21,892; 54.9%) were enrolled. The patients with IVT had a greater history of venous thromboembolism than those diagnosed with SVT (p<.001). The initial treatment was similar for the 2 groups, but more inferior vena cava filters were placed in the SVT group (p<.001). In the long term, low-molecular-weight heparin was used more often in the SVT group than in the IVT group. At 90days, bleeding, death and the recurrence of venous thromboembolism were significantly more frequent in the SVT group. The multivariate analysis confirmed that IVT was associated with fewer major (OR, 0.60; 95%CI, 0.50-0.61; p<.001) and fatal (OR, 0.41; 95%CI, 0.29-0.62; p<.001) bleedings, fewer relapses (OR, 0.58; 95%CI, 0.39-0.78; p<.001) and fewer fatal pulmonary embolisms (OR, 0.29; 95%CI, 0.12-0.52; p<.001). These differences were maintained in patients whose venous thromboembolism started with a pulmonary embolism or with deep vein thrombosis. IVT has a better prognosis than SVT at 90days of the diagnosis. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  11. The vanadium/oxygen system in the analysis of sodium for oxygen

    International Nuclear Information System (INIS)

    Walker, J.A.J.; Price, W.B.

    1981-05-01

    An investigation of the V-O-Na system at 1023 K is described for oxygen in sodium contents of 5 to 25 ppm. Electron spectroscopy combined with depth profiling is used to determine the vanadium/oxygen ratios inwards from the surface of vanadium foil and these ratios are compared with theoretical predictions. The validity of the vanadium wire technique as an analytical method is examined and a model for the vanadium oxidation is suggested. (author)

  12. CT findings of posterior fossa venous angiomas

    International Nuclear Information System (INIS)

    Satoh, Toru; Kinugasa, Kazushi; Nishimoto, Akira; Nishimoto, Ken.

    1986-01-01

    Three cases of posterior fossa venous angiomas were reported, with some comments on the CT findings. Case 1: A 53-year-old woman was admitted for the further examination of a viral meningitis which had appeared three months before. Neurological examination revealed no abnormality. Vertebral angiography, however, demonstrated numerous fine medullary veins, with an enlarged intraparenchymal draining vein, in the right cerebellum; they drained into the petrosal vein, which was characteristic of venous angioma. On the plain CT, part of the draining vein was identified as a slightly high-density node. A curvilinear draining vein was demonstrated by the enhanced CT. Case 2: A 29-year-old man was admitted complaining of headache, vomiting, and atxia. Neurological examination disclosed truncal ataxia. The enhanced CT demonstrated two distinct nodules on the anterior border of the hematoma in the deep median cerebellum, probably corresponding to the draining veins. On the angiogram, a venous angioma was found in the bilateral cerebellum; it drained into the precentral cerebellar veins and ultimately joined the straight sinus via the precentro-vermo-rectal vein. Case 3: A 4-year-old boy was admitted suffering from headache, vomiting, and ataxia. Neurological examination disclosed a co-ordination disturbance of the left side. The enhanced CT demonstrated a curvilinear structure inside the hematoma. Angiography showed a venous angioma in the left cerebellum which drained into the petrosal vein. Computerized angiotomography delineated the characteristic venous structure on the angiogram as many fine, high-density lines (medullary veins) converging to a large intraparenchymal linear structure (central medullary vein) and then to a superficial cortical vein. In all cases, large intraparenchymal draining veins were identified by the conventional CT. (J.P.N.)

  13. Preretinal partial pressure of oxygen gradients before and after experimental pars plana vitrectomy.

    Science.gov (United States)

    Petropoulos, Ioannis K; Pournaras, Jean-Antoine C; Stangos, Alexandros N; Pournaras, Constantin J

    2013-01-01

    To evaluate preretinal partial pressure of oxygen (PO2) gradients before and after experimental pars plana vitrectomy. Arteriolar, venous, and intervascular preretinal PO2 gradients were recorded in 7 minipigs during slow withdrawal of oxygen-sensitive microelectrodes (10-μm tip diameter) from the vitreoretinal interface to 2 mm into the vitreous cavity. Recordings were repeated after pars plana vitrectomy and balanced salt solution (BSS) intraocular perfusion. Arteriolar, venous, and intervascular preretinal PO2 at the vitreoretinal interface were 62.3 ± 13.8, 22.5 ± 3.3, and 17.0 ± 7.5 mmHg, respectively, before vitrectomy; 97.7 ± 19.9, 40.0 ± 21.9, and 56.3 ± 28.4 mmHg, respectively, immediately after vitrectomy; and 59.0 ± 27.4, 25.2 ± 3.0, and 21.5 ± 4.5 mmHg, respectively, 2½ hours after interruption of BSS perfusion. PO2 2 mm from the vitreoretinal interface was 28.4 ± 3.6 mmHg before vitrectomy; 151.8 ± 4.5 mmHg immediately after vitrectomy; and 34.8 ± 4.1 mmHg 2½ hours after interruption of BSS perfusion. PO2 gradients were still present after vitrectomy, with the same patterns as before vitrectomy. Preretinal PO2 gradients are not eliminated after pars plana vitrectomy. During BSS perfusion, vitreous cavity PO2 is very high. Interruption of BSS perfusion evokes progressive equilibration of vitreous cavity PO2 with concomitant progressive return of preretinal PO2 gradients to their previtrectomy patterns. This indicates that preretinal diffusion of oxygen is not altered after vitrectomy. The beneficial effect of vitrectomy in ischemic retinal diseases or macular edema may be related to other mechanisms, such as increased oxygen convection currents or removal of growth factors and cytokines secreted in the vitreous.

  14. Complication of Hemodialysis Access: A Case Report of Venous Hypertension

    Directory of Open Access Journals (Sweden)

    Sadegh Asadi

    2018-03-01

    Full Text Available Vascular access for dialysis is essential for these patients with end-stage renal disease, improvements in hemodialysis managment have lead to extended life expectancy. The creation and maintenance of hemoaccess occupies a significant portion of most vascular and general surgery practices.Venous hypertension due to arteriovenous fistula is usually secondary to venous outlet obstruction. Side to side proximal artery arteriovenous fistula serves as a certain cause of hemodialysis, but it is rarely reported as a peripheral venous hypertension cause. We are reporting a case with developed venous hypertension having dermal injuries in the arm. The patient underwent successful side-to-side radio cephalic fistula creation in the snuffbox a year ago.

  15. Partial anomalous pulmonary venous return in patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Sung, Won-kyung; Au, Virginia; Rose, Anand

    2012-01-01

    Anomalous pulmonary venous return is an uncommon congenital malformation, and may be partial or total. Partial anomalous pulmonary venous return (PAPVR) is more common than total anomalous pulmonary venous return, and is often associated with other congenital cardiac anomalies. Whilst many patients with PAPVR remain asymptomatic, some may present in later age with symptoms related to left-to-right shunt, right heart failure and pulmonary hypertension. We report two cases of PAPVR detected on Computed Tomography Pulmonary Angiogram (CTPA) for the work up of pulmonary hypertension. The cases demonstrate that, although uncommon, partial anomalous pulmonary venous return can be a contributing factor to pulmonary hypertension and pulmonary veins should be carefully examined when reading a CTPA study.

  16. Central Venous Occlusion in the Hemodialysis Patient.

    Science.gov (United States)

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  17. Investigation of cerebral venous outflow in microgravity.

    Science.gov (United States)

    Taibi, A; Gadda, G; Gambaccini, M; Menegatti, E; Sisini, F; Zamboni, P

    2017-10-31

    The gravitational gradient is the major component to face when considering the physiology of venous return, and there is a growing interest in understanding the mechanisms ensuring the heart filling, in the absence of gravity, for astronauts who perform long-term space missions. The purpose of the Drain Brain project was to monitor the cerebral venous outflow of a crew member during an experiment on the International Space Station (ISS), so as to study the compensatory mechanisms that facilitate this essential physiological action in subjects living in a microgravity environment. Such venous function has been characterized by means of a novel application of strain-gauge plethysmography which uses a capacitive sensor. In this contribution, preliminary results of our investigation have been presented. In particular, comparison of plethysmography data confirmed that long duration spaceflights lead to a redistribution of venous blood volume, and showed interesting differences in the amplitude of cardiac oscillations measured at the level of the neck veins. The success of the experiment has also demonstrated that thanks to its easy portability, non-invasiveness, and non-operator dependence, the proposed device can be considered as a novel tool for use aboard the ISS. Further trials are now under way to complete the investigation on the drainage function of the neck veins in microgravity.

  18. Venous and autonomic function in formerly pre-eclamptic women and BMI-matched controls.

    Science.gov (United States)

    Heidema, Wieteke M; van Drongelen, Joris; Spaanderman, Marc E A; Scholten, Ralph R

    2018-03-25

    Pre-pregnancy reduced plasma volume increases the risk on subsequent pre-eclamptic pregnancy. Reduced plasma volume is thought to reflect venous reserve capacity, especially when venous vasculature is constricted and sympathetic tone is elevated. As obesity might affect these variables and also relates to pre-eclampsia, increased body weight may underlie these observations. We hypothesized that the relationship between reduced venous reserve and preeclampsia is independent of body mass index (BMI). We compared the non-pregnant venous reserve capacity in 30 formerly pre-eclamptic women, equally divided in 3 BMI-classes (BMI 19.5-24.9, BMI 25-29.9, BMI ≥30) to 30 controls. Cases and controls were matched for BMI, age and parity. The venous reserve capacity was quantified by assessing plasma volume and venous compliance. The autonomic nervous system regulating the venous capacitance was evaluated with heart rate variability analysis in resting supine position and during positive head-up tilt (HUT). Formerly pre-eclamptic women had in supine position lower plasma volume than controls (1339 ± 79 vs 1547 ± 139 ml/m 2 (pBMI-matched controls, reduced venous reserve capacity. This is reflected by lower plasma volume and venous compliance, the autonomic balance is shifted towards sympathetic dominance and lower baroreceptor sensitivity. This suggests that not BMI, but underlying reduced venous reserve relates to pre-eclampsia. This article is protected by copyright. All rights reserved.

  19. Cortical venous disease severity in MELAS syndrome correlates with brain lesion development.

    Science.gov (United States)

    Whitehead, M T; Wien, M; Lee, B; Bass, N; Gropman, A

    2017-08-01

    MELAS syndrome is a mitochondrial disorder typified by recurrent stroke-like episodes, seizures, and progressive brain injury. Abnormal mitochondria have been found in arterial walls implicating a vasculogenic etiology. We have observed abnormal cortical vein T2/FLAIR signal in MELAS patients, potentially representing wall thickening and sluggish flow. We sought to examine the relationship of hyperintense veins and brain lesions in MELAS. Imaging databases at two children's hospitals were searched for brain MRIs from MELAS patients. Artifact, sedated exams, and lack of 2D-T2/FLAIR sequences were exclusion criteria. Each exam was assigned a venous score based on number of T2/FLAIR hyperintense veins: 1 = 20. Cumulative brain lesions and venous score in MELAS and aged-matched normal exams were compared by Mann-Whitney test. A total of 106 exams from 14 unique MELAS patients (mean 16 ± 3 years) and 30 exams from normal aged-matched patients (mean 15 ± 3 years) were evaluated. Median venous score between MELAS and control patients significantly differed (3 versus 1; p MELAS group, venous score correlated with presence (median = 3) or absence (median = 1) of cumulative brain lesions. In all 8 MELAS patients who developed lesions, venous hyperintensity was present prior to, during, and after lesion onset. Venous score did not correlate with brain lesion acuity. Abnormal venous signal correlates with cumulative brain lesion severity in MELAS syndrome. Cortical venous stenosis, congestion, and venous ischemia may be mechanisms of brain injury. Identification of cortical venous pathology may aid in diagnosis and could be predictive of lesion development.

  20. Increased cerebral output of free radicals during hypoxia: implications for acute mountain sickness?

    DEFF Research Database (Denmark)

    Bailey, Damian M; Taudorf, Sarah; Berg, Ronan M G

    2009-01-01

    This study examined whether hypoxia causes free radical-mediated disruption of the blood-brain barrier (BBB) and impaired cerebral oxidative metabolism and whether this has any bearing on neurological symptoms ascribed to acute mountain sickness (AMS). Ten men provided internal jugular vein...... paramagnetic resonance spectroscopy and ozone-based chemiluminescence were employed for direct detection of spin-trapped free radicals and nitric oxide metabolites. Neuron-specific enolase (NSE), S100beta, and 3-nitrotyrosine (3-NT) were determined by ELISA. Hypoxia increased the arterio-jugular venous...... concentration difference (a-v(D)) and net cerebral output of lipid-derived alkoxyl-alkyl free radicals and lipid hydroperoxides (P

  1. Vascular plugs - A key companion to Interventionists - 'Just Plug it'.

    Science.gov (United States)

    Ramakrishnan, Sivasubramanian

    2015-01-01

    Vascular plugs are ideally suited to close extra-cardiac, high flowing vascular communications. The family of vascular plugs has expanded. Vascular plugs in general have a lower profile and the newer variants can be delivered even through a diagnostic catheter. These features make them versatile and easy to use. The Amplatzer vascular plugs are also used for closing intracardiac defects including coronary arterio-venous fistula and paravalvular leakage in an off-label fashion. In this review, the features of currently available vascular plugs are reviewed along with tips and tricks of using them in the cardiac catheterization laboratory. Copyright © 2015. Published by Elsevier B.V.

  2. Hepatic telangiectasia in Osler's disease treated with arterial embolization

    Energy Technology Data Exchange (ETDEWEB)

    Goethlin, J H; Nordgard, K; Jonsson, K; Nyman, U

    1982-02-01

    Hepatic hereditary telangiectasia in 2 females was treated with hepatic artery embolization. In one patient both peripheral and central arterial occlusion was performed; the patient died of massive gastro-intestinal bleeding 2 months later. Autopsy showed extensive regions with necrosis in the right liver lobe. In the next patient only central occlusion of the right hepatic artery was performed and the arterio-venous shunting in the left liver lobe left remaining. After a long reconvalescence period the patient recovered completely. It is advocated to centrally occlude only that hepatic artery supplying the most affected parts of the liver in Osler's disease. Thus extensive necrosis with possible ensuing death may be avoided.

  3. Direct Open Venous Drainage: An Alternative Choice for Flap Congestion Salvage.

    Science.gov (United States)

    Park, Su Han; Choi, Woo Young; Son, Kyung Min; Cheon, Ji Seon; Yang, Jeong Yeol

    2015-12-01

    In this report, we present a scalp defect reconstruction with lateral arm free flap. We highlight the difficulty in obtaining a recipient vein and the venous drainage managed through an open end of the donor vein. A 52-year-old woman presented with a pressure sore on the left scalp. A lateral arm free flap was transferred to cover this 8×6 cm defect. The arterial anastomosis was successful, but no recipient vein could be identified within the wound bed. Instead, we used a donor venous end for the direct open venous drainage. In order to keep this exposed venous end patent, we applied heparin-soaked gauze dressing to the wound. Also, the vein end was mechanically dilated and irrigated with heparin solution at two hour intervals. Along with fluid management and blood transfusion, this management was continued for the five days after the operation. The flap survived well without any complication. Through this case, we were able to demonstrate that venous congestion can be avoided by drainage of the venous blood through an open vessel without the use of leeches.

  4. Massive hydrothorax with malpositioned central venous catheter – Ultrasound detection

    Directory of Open Access Journals (Sweden)

    Neha Hasija

    2016-04-01

    Full Text Available Radioimaging is the gold standard for confirmation of the position of central venous catheter as well as its related complications. Use of ultrasound has been proven in guiding central venous cannulations, and it can also be used in detecting related complications. We report a case of a 2 year old child with hydrothorax causing desaturation due to malpositioned central venous catheter diagnosed by ultrasound in the delay for getting a radiograph.

  5. The Role of Complex Treatment in Mixed Leg Ulcers - A Case Report of Vascular, Surgical and Physical Therapy.

    Science.gov (United States)

    Wollina, Uwe; Heinig, Birgit; Stelzner, Christian; Hansel, Gesina; Schönlebe, Jacqueline; Tchernev, Georgi; Lotti, Torello

    2018-01-25

    Leg ulcers are a burden to patients, their families and society. The second most common cause of chronic leg ulcers is the mixed arterio-venous type. An 80-year-old female patient presented to our department due to painful enlarging chronic leg ulcer of mixed arteriovenous origin on her left lower leg. She suffered from peripheral arterial occlusive disease stage I and chronic venous insufficiency Widmer grade IIIa, and a number of comorbidities. The aim of our ulcer treatment was a complete and stable wound closure that was hampered by arterial occlusion, exposed tendon, and renal insiffuciency. To improve the prognosis for ulcer surgery, we performed percutaneous transluminal angioplasty, transcutaneous CO 2 and deep ulcer shaving. The wound was closed by sandwich transplantation using elastin-collagen dermal template and meshed split skin graft. She had a 100% graft take with rapid reduction of severe wound pain. Complex approaches are necessary, to gain optimum results in leg ulcer therapy in mixed leg ulcers. Therapeutic nihilism should be abandonend.

  6. Venous access: options, approaches and issues

    International Nuclear Information System (INIS)

    Asch, M.R.

    2001-01-01

    Venous access is an essential part of medical practice. It is needed to obtain blood samples to make the diagnosis and to administer fluids or medicines as part of treatment. Although relatively new in the history of medicine, the placement and maintenance of the various venous access devices now occupies a significant portion of many vascular and interventional radiology practices. Thus, it is important to have a thorough understanding of these devices and their uses. The first long-term venous access devices were used in 1973. These were placed via a surgical cut-down on the subclavian vein. In 1982, the first subcutaneous implantable ports were described. These procedures were initially performed by surgeons, but over the last 5-10 years, both the insertion and management of these devices has shifted to interventional radiologists. Peripherally inserted central catheter (PICC) lines have almost completely supplanted the use of standard central lines (Fig. 1). A number of factors have facilitated this - namely, ready and less expensive room access, outpatient procedure and radiologists' accessibility and familiarity with image-guidance procedures and catheters and guide wires. (author)

  7. Evaluation of the renal venous system on late arterial and venous phase images with MDCT angiography in potential living laparoscopic renal donors

    International Nuclear Information System (INIS)

    Kawamoto, S.; Lawler, L.P.; Fishman, E.K.

    2005-01-01

    Objective: The objective of our study was to assess whether both renal arteries and renal veins can be evaluated using single-phase MDCT data sets alone to eliminate the need for both arterial and venous phase data sets. Materials and methods: One hundred consecutive potential living renal donors who underwent 4- MDCT were evaluated. CT was performed with 120 mL of IV contrast material at an injection rate of 3 mL/sec. Both late arterial and venous phase acquisitions were obtained at 25 and 55 sec from the start of IV contrast injection, respectively. The number of the right and left renal veins and its anatomic variations were assessed by two reviewers. Late arterial phase images were evaluated initially, and then venous phase images were analyzed to assess opacification of the renal vein and to see whether venous phase data sets changed or added information about the venous anatomy as seen on late arterial phase images. Results: The retroaortic left renal vein was found in two subjects, and the circumaortic left renal vein was detected in three subjects. The renal veins were adequately opacified on late arterial phase images in all subjects. There were six subjects who had a normal left renal vein with a small posterior branch coursing posterior to the aorta and draining into the inferior vena cava, which were difficult to differentiate from the lumbar vein or ascending lumbar vein; in three of these six subjects, the small posterior branch was opacified only on venous phase images. Conclusion: Late arterial phase images obtained at 25 sec after the start of contrast injection can reveal the renal vein anatomy except for a small posterior branch of the left renal vein difficult to differentiate from the lumbar or ascending lumbar vein, as seen in three subjects. The data suggest that venous phase imaging is not necessary for the evaluation of renal vein anatomy. (author)

  8. Evaluation of the renal venous system on late arterial and venous phase images with MDCT angiography in potential living laparoscopic renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Kawamoto, S.; Lawler, L.P.; Fishman, E.K. [Johns Hopkins Hospital, Baltimore, MD (United States). The Russell H. Morgan Department of Radiology and Radiological Science

    2005-03-15

    Objective: The objective of our study was to assess whether both renal arteries and renal veins can be evaluated using single-phase MDCT data sets alone to eliminate the need for both arterial and venous phase data sets. Materials and methods: One hundred consecutive potential living renal donors who underwent 4- MDCT were evaluated. CT was performed with 120 mL of IV contrast material at an injection rate of 3 mL/sec. Both late arterial and venous phase acquisitions were obtained at 25 and 55 sec from the start of IV contrast injection, respectively. The number of the right and left renal veins and its anatomic variations were assessed by two reviewers. Late arterial phase images were evaluated initially, and then venous phase images were analyzed to assess opacification of the renal vein and to see whether venous phase data sets changed or added information about the venous anatomy as seen on late arterial phase images. Results: The retroaortic left renal vein was found in two subjects, and the circumaortic left renal vein was detected in three subjects. The renal veins were adequately opacified on late arterial phase images in all subjects. There were six subjects who had a normal left renal vein with a small posterior branch coursing posterior to the aorta and draining into the inferior vena cava, which were difficult to differentiate from the lumbar vein or ascending lumbar vein; in three of these six subjects, the small posterior branch was opacified only on venous phase images. Conclusion: Late arterial phase images obtained at 25 sec after the start of contrast injection can reveal the renal vein anatomy except for a small posterior branch of the left renal vein difficult to differentiate from the lumbar or ascending lumbar vein, as seen in three subjects. The data suggest that venous phase imaging is not necessary for the evaluation of renal vein anatomy. (author)

  9. [Actual questions about the prevention of venous thromboembolism in cancer patients receiving chemotherapy].

    Science.gov (United States)

    Losonczy, Hajna; Nagy, Ágnes; Tar, Attila

    2016-02-07

    Cancer patients have a 2-7 fold increased risk of venous thromboembolism compared with the general population and, since 1990, this is associated with significant morbidity and mortality. This review summarizes the current knowledge on venous thromboembolism and cancer. Notably, the risk of venous thromboembolism varies depending on the type and stage of cancer. For instance, pancreatic and brain cancer patients have a higher risk of venous thromboembolism than breast and prostate cancer patients. Moreover, patients with metastatic disease have a higher risk than those with localized tumors. Tumor-derived procoagulant factors, cytokines and growth factors may directly and indirectly enhance venous thromboembolism. Chemotherapy produces ~6,5 fold increase in venous thromboembolism incidence in cancer patients compared to the general population. Prevention of this complication is challenging. The authors review the development of guidelines concerning venous thromboembolism prevention in hospitalized and also in ambulatory cancer patients treated with chemotherapy. Current guidelines recommend the use of low-molecular-weight heparin. Understanding the underlying mechanisms may allow the development of new therapies to safely prevent venous thromboembolism in cancer patients.

  10. Klippel-Trenaunay syndrome in a Border collie.

    Science.gov (United States)

    de Cock, H; Mols, N; van Roy, M R; Ducatelle, R; Simoens, P

    1996-10-01

    A Border collie was presented at the age of 9 weeks with several lesions of the right forelimb, including a reddish-blue haemangiomatous macula in the medio-dorsal part of the elbow, multiple, scattered small cavernous haemangioma-like lesions at the plantar part of the foot and a general hypertrophy of the limb. X-rays of the limb showed osteolysis. On skin biopsy, telangiectatic veins were observed. The rest of the body did not show any skin lesions or hypertrophy. The dog was otherwise healthy. Due to the extension of the lesions and worsening of the limb swelling, it was decided to amputate the affected limb. The dog remained healthy for 2 weeks, but then passed through episodes of anaemia, and finally died suddenly with signs of shock. Dissection of the limb after amputation revealed hypoplasia and aplasia of the deep venous system in the lower part of the leg. No arterio-venous shunts were noticed. ln man, this syndrome, characterised by an insufficiently developed deep venous system associated with local overgrowth of the limb and cutaneous telangiectasia, is known as Klippel-Trenaunay syndrome.

  11. Rivaroxaban or Aspirin for Extended Treatment of Venous Thromboembolism

    NARCIS (Netherlands)

    Weitz, Jeffrey I.; Lensing, Anthonie W. A.; Prins, Martin H.; Bauersachs, Rupert; Beyer-Westendorf, Jan; Bounameaux, Henri; Brighton, Timothy A.; Cohen, Alexander T.; Davidson, Bruce L.; Decousus, Hervé; Freitas, Maria C. S.; Holberg, Gerlind; Kakkar, Ajay K.; Haskell, Lloyd; van Bellen, Bonno; Pap, Akos F.; Berkowitz, Scott D.; Verhamme, Peter; Wells, Philip S.; Prandoni, Paolo; Bianchi, Alessandra; Brighton, Tim; Carroll, Patrick; Chong, Beng; Chunilal, Sanjeev; Coughlin, Paul; Curnow, Jennifer; Jackson, David; Tran, Huyen; Ward, Chris; Brodmann, Marianne; Kyrle, Paul; Marschang, Peter; Petkov, Ventzislav; Hainaut, Philippe; Jordens, Paul; Vandekerkhof, Jos; Wautrecht, Jean-Claude; Annichino-Bizzacchi, Joyce; Correa, Joao; Cukier, Alberto; Freire, Antonio; Pereira, Adamastor; Porto, Carmen; Sacilotto, Roberto; Vasconcelos Costa, Agenor; Della Siega, Anthony; Dolan, Sean; Le Gal, Gré goire; Middeldorp, Saskia

    2017-01-01

    BACKGROUND Although many patients with venous thromboembolism require extended treatment, it is uncertain whether it is better to use full- or lower-intensity anticoagulation therapy or aspirin. METHODS In this randomized, double-blind, phase 3 study, we assigned 3396 patients with venous

  12. The hydrogen and oxygen content of self-supporting carbon foils prepared by dc glow discharge in ethylene

    International Nuclear Information System (INIS)

    Tait, N.R.S.; Tolfree, D.W.L.; John, P.; Odeh, I.M.; Thomas, M.J.K.; Tricker, M.J.; Wilson, J.J.B.; England, J.B.A.; Newton, D.

    1980-01-01

    The hydrogen and oxygen content of self-supporting carbon films produced by dc glow discharge have been determined using a precise method involving the elastic scattering of 25 MeV α-particles. The number of carbon-hydrogen bonds has been determined for similar samples using infrared spectroscopy. The results are compared with those for samples made by the carbon arc process. Assuming that the glow discharge carbon contains graphitic regions surrounded by amorphous tetrahedrally bonded material to which hydrogen can attach, a simple estimate is made of the relative numbers of carbon atoms in the two forms. (orig.)

  13. Influence of oxygen content on some properties of Nb3Sn tape used for superconducting transmission lines

    International Nuclear Information System (INIS)

    Jergel, M.; Melisek, T.; Allarova, H.; Synak, D.; Neuschl, J.; Ivan, J.

    1982-01-01

    The influence of the presence of oxygen in the Nb-Zr substrate upon some physical and mechanical properties of the Nb-ZrO 2 substrate and/or Nb 3 Sn tape superconductor prepared from such a substrate has been studied The results have shown that the Nb 3 Sn grains are much finer in the case of Nb-ZrO 2 , than those obtained on Nb-Zr substrate. As a result, both the electrical and mechanical properties have been substantially improved. The critical current at a field of 5 T increased by between 100 and 200%, the alternating current losses decreased by about one order of magnitude, the tensile strength increased by about a factor of three and the microhardness value also increased by about a factor of three for oxygen contents in the range 0.03 to 0.70 wt%. The specific resistance of this substrate increased at the same time from 17 to 22 μΩ cm and the relative elongation decreased from 5 to 3%. (author)

  14. Effects of abdominal pressure on venous return: abdominal vascular zone conditions.

    Science.gov (United States)

    Takata, M; Wise, R A; Robotham, J L

    1990-12-01

    The effects of changes in abdominal pressure (Pab) on inferior vena cava (IVC) venous return were analyzed using a model of the IVC circulation based on a concept of abdominal vascular zone conditions analogous to pulmonary vascular zone conditions. We hypothesized that an increase in Pab would increase IVC venous return when the IVC pressure at the level of the diaphragm (Pivc) exceeds the sum of Pab and the critical closing transmural pressure (Pc), i.e., zone 3 conditions, but reduce IVC venous return when Pivc is below the sum of Pab and Pc, i.e., zone 2 conditions. The validity of the model was tested in 12 canine experiments with an open-chest IVC bypass. An increase in Pab produced by phrenic stimulation increased the IVC venous return when Pivc-Pab was positive but decreased the IVC venous return when Pivc - Pab was negative. The value of Pivc - Pab that separated net increases from decreases in venous return was 1.00 +/- 0.72 (SE) mmHg (n = 6). An increase in Pivc did not influence the femoral venous pressure when Pivc was lower than the sum of Pab and a constant, 0.96 +/- 0.70 mmHg (n = 6), consistent with presence of a waterfall. These results agreed closely with the predictions of the model and its computer simulation. The abdominal venous compartment appears to function with changes in Pab either as a capacitor in zone 3 conditions or as a collapsible Starling resistor with little wall tone in zone 2 conditions.

  15. The certification of oxygen in copper CRM No 054R

    International Nuclear Information System (INIS)

    1989-01-01

    A reference material for the determination of low oxygen contents in copper (CRM 054R) has been prepared to replace the exhausted CRM 054. The homogeneity of the material is demonstrated. The oxygen content has been determined by charged particle activation analysis and confirmed by fusion extraction techniques. The mass fraction of oxygen is certified as (0.47 ± 0.04) μ g/g. 10 refs

  16. Complication of venous thrombosis of the lower extremities with pulmonary embolism

    International Nuclear Information System (INIS)

    Suzuki, Teruyasu; Morita, Rikushi

    1993-01-01

    We studied the relationship between the complication of the pulmonary embolism and the localization of the venous thrombus in the lower extremities using Tc-99m macroaggregated albumin (MAA) venography. Tc-99m MAA venography clearly demonstrated most of the deep and superficial veins from the leg to the pelvis and the abdomen. The incidence of venous thrombosis was highest in the pelvic veins (28.8%), and second in the superficial leg veins (10.9%). The complication of pulmonary embolism was highest in the pelvic venous thrombosis (20.4%), and second in the femoral venous thrombosis (16.0%). (author)

  17. Central venous stenosis among hemodialysis patients is often not associated with previous central venous catheters.

    Science.gov (United States)

    Kotoda, Atsushi; Akimoto, Tetsu; Kato, Maki; Kanazawa, Hidenori; Nakata, Manabu; Sugase, Taro; Ogura, Manabu; Ito, Chiharu; Sugimoto, Hideharu; Muto, Shigeaki; Kusano, Eiji

    2011-01-01

    It is widely assumed that central venous stenosis (CVS) is most commonly associated with previous central venous catheterization among the chronic hemodialysis (HD) patients. We evaluated the validity of this assumption in this retrospective study. The clinical records from 2,856 consecutive HD patients with vascular access failure during a 5-year period were reviewed, and a total of 26 patients with symptomatic CVS were identified. Combined with radiological findings, their clinical characteristics were examined. Only seven patients had a history of internal jugular dialysis catheterization. Diagnostic multidetector row computed tomography angiography showed that 7 of the 19 patients with no history of catheterization had left innominate vein stenosis due to extrinsic compression between the sternum and arch vessels. These patients had a shorter period from the time of creation of the vascular access to the initial referral (9.2 ± 7.6 months) than the rest of the patients (35.5 ± 18.6 months, p = 0.0017). Our findings suggest that cases without a history of central venous catheterization may not be rare among the HD patients with symptomatic CVS. However, those still need to be confirm by larger prospective studies of overall chronic HD patients with symptomatic CVS.

  18. In situ measurements of oxygen dynamics in unsaturated archaeological deposits

    DEFF Research Database (Denmark)

    Matthiesen, Henning; Hollesen, Jørgen; Dunlop, Rory

    2015-01-01

    Oxygen is a key parameter in the degradation of archaeological material, but little is known of its dynamics in situ. In this study, 10 optical oxygen sensors placed in a 2 m deep test pit in the cultural deposits at Bryggen in Bergen have monitored oxygen concentrations every half hour for more ...... of the soil exceeds 10–15% vol, while oxygen dissolved in infiltrating rainwater is of less importance for the supply of oxygen in the unsaturated zone....... than a year. It is shown that there is a significant spatial and temporal variation in the oxygen concentration, which is correlated to measured soil characteristics, precipitation, soil water content and degradation of organic material. In these deposits oxygen typically occurs when the air content...

  19. Risk factors for venous port migration in a single institute in Taiwan

    OpenAIRE

    Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen

    2014-01-01

    Background An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. Methods This retrospective study of venous port implantation in a single center, a Taiw...

  20. Venous Thromboembolism and Risk of Idiopathic Interstitial Pneumonia A Nationwide Study

    DEFF Research Database (Denmark)

    Sode, Birgitte Margareta; Dahl, Morten; Nielsen, Sune Fallgaard

    2010-01-01

    Rationale: Idiopathic interstitial pneumonia is characterized by pulmonary fibrosis and high mortality. Objectives: We examined the association between ever-diagnosed venous thromboembolism and risk of incident idiopathic interstitial pneumonia. Venous thromboembolism was taken as a proxy...... Danish registries. Measurements and Main Results: Age-standardized incidence rates per 10,000 person-years for idiopathic interstitial pneumonia were higher among those ever diagnosed with venous thromboembolism (1.8; n = 158,676), pulmonary embolism (2.8; n = 70,586), and deep venous thrombosis only (1.......2; n = 88,090), than among control subjects (0.8; n = 7,260,278). Multivariate-adjusted hazard ratios for idiopathic interstitial pneumonia were 1.8 (95% confidence interval [Cl], 1.7-1.9) in those ever diagnosed with venous thromboembolism, 2.4 (95% CI, 2.3-2.6) in those ever diagnosed with pulmonary...

  1. Duplex correlation phlebography in venous mapping of the upper limbs for artery venous fistulas for hemodialysis

    International Nuclear Information System (INIS)

    Esperon Percovich, A.; Lopez Chapuis, D.; Velverdu, M.; Curi, J.; Sciuto, F.; Velverdu, M.; Curi, J.

    1995-01-01

    When clinical evaluation is not enough,the evaluation of the venous condition of the upper limbs for the realization of angio access for hemodialysis is classically based on phlebography,an invasive,risky method.the appear rance of non invasive techniques such as eco Doppler(duplex) makes it necessary to do research in order to determine the utility of the method and define its indications.The authors analyse 35 venous mappings of the upper limbs by phlebography and duplex and compare its results for the different venous regions.They come to the conclusion that duplex presented the best performance for the hum ero axillary subclavian region,detecting thrombosis with a sensitivity of 100% a specificity of 97% positive predictive value of 50% and negative predictive value of 100%.For superficial axis (radial and superficial ulnar,basilic and cephalic)there is low sensitivity for the determination of presence and permeability of the axis but 100% specificity.Duplex was not useful for the description of veins in order to determine utility for Avf.Finally,the authors make recommendations as regards indications of these para clinical tests [es

  2. Detection of haemoglobins with abnormal oxygen affinity by single blood gas analysis and 2,3-diphosphoglycerate measurement.

    Science.gov (United States)

    Guerrini, G; Morabito, A; Samaja, M

    2000-10-01

    The aim is to determine if a single measurement of blood 2,3-diphosphoglycerate combined with gas analysis (pH, PCO2, PO2 and saturation) can identify the cause of an altered blood-oxygen affinity: the presence of an abnormal haemoglobin or a red cell disorder. The population (n=94) was divided into healthy controls (A, n=14), carriers of red cell disorders (B, n=72) and carriers of high oxygen affinity haemoglobins (C, n=8). Those variables were measured both in samples equilibrated at selected PCO2 and PO2 and in venous blood. In the univariable approach applied to equilibrated samples, we correctly identified C subjects in 93.6% or 96.8% of the cases depending on the selected variable, the standard P50 (PO2 at which 50% of haemoglobin is oxygenated) or a composite variable calculated from the above measurements. After introducing the haemoglobin concentration as a further discriminating variable, the A and B subjects were correctly identified in 91.9% or 94.2% of the cases, respectively. These figures become 93.0% or 86.1%, and 93.7% or 94.9% of the cases when using direct readings from venous blood, thereby avoiding the blood equilibration step. This test is feasible also in blood samples stored at 4 degrees C for 48 h, or at room temperature for 8 h.

  3. Near-infrared vascular imaging in peripheral venous and arterial access

    OpenAIRE

    Cuper, N.J.

    2012-01-01

    Venous and arterial access are among the most widespread medical procedures performed in children. Especially in young children venous and arterial access can be problematic due to tiny blood vessels that are difficult to localize beneath a layer of baby fat. This thesis describes the development and clinical evaluation of the VascuLuminator, a guidance tool for peripheral venous and arterial access by visualizing blood vessels underneath the skin with near-infrared light. In a third to a fif...

  4. The effect of ankle joint immobilization on lower limb venous flow.

    Science.gov (United States)

    Craik, Johnathan D; Clark, Amanda; Hendry, James; Sott, Andrea H; Hamilton, Paul D

    2015-01-01

    Below-knee cast immobilization is associated with an increased risk of developing deep vein thrombosis secondary to venous stasis. We investigated the effect of weight-bearing in a below-knee cast or pneumatic walking boot on lower limb venous blood flow. Duplex ultrasonography was used to measure venous blood flow in the popliteal vein of 10 healthy volunteers. Venous blood flow was measured while at rest, ambulating non-weight-bearing, partial weight-bearing, and full weight-bearing. Measurements were performed without ankle joint immobilization, with the ankle immobilized in a neutral cast, and with the ankle immobilized in a pneumatic walking boot in both neutral and equinus. There was no significant reduction in venous blood flow measurements between full weight-bearing without ankle joint immobilization and full weight-bearing in a neutral cast or neutral pneumatic walking boot. However, venous blood flow was reduced when partial weight-bearing (50%) and when full weight-bearing in a pneumatic walking boot in equinus. These results demonstrate that venous blood flow returned to normal levels when the subjects were permitted to fully bear weight in below-knee casts or walking boots, provided that the ankle joint was not in equinus. Weight-bearing status and ankle joint position should be appreciated during decisions for the provision of chemical thromboprophylaxis. © The Author(s) 2014.

  5. Risk factors for venous port migration in a single institute in Taiwan.

    Science.gov (United States)

    Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen

    2014-01-14

    An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor.

  6. Urinary hemosiderin: role in evaluation of chronic venous insufficiency

    Directory of Open Access Journals (Sweden)

    Ashish Lal Shrestha

    2012-08-01

    Full Text Available Chronic venous insufficiency (CVI leads to skin changes with dermal hemosiderin deposition. We studied the presence of hemosiderin in the urine to assess if this could be used as a biochemical marker for CVI. Hereby we present a case control study conducted in a tertiary care centre in South India. There were 100 cases with evidence of advanced CVI (the Clinical-Etiology-Anatomy-Pathophysiology classification: C5, C6 confirmed by duplex scanning. Controls were 50 patients with leg ulcers due to other etiologies. All patients were subjected to urinary hemosiderin testing. In all 100 patients with CVI (C5 and C6 disease axial venous reflux was confirmed by duplex ultrasound. Superficial venous reflux was noted in 71% of patients and deep venous reflux in 54.%. Primary venous insufficiency was the etiology in 81% of patients. Only 4/100 patients had detectable amounts of hemosiderin in the urine. Urine hemosiderin testing to determine presence or absence of CVI yielded the following values: positive predictive value-80%; negative predictive value-33%; sensitivity-4% and specificity-98%. The test could not be recommended as a marker of CVI. In Indian patients urinary hemosiderin is not a useful screening test in CVI.

  7. Pulmonary hemodynamics and gas exchange in off pump coronary artery bypass grafting.

    Science.gov (United States)

    Vedin, Jenny; Jensen, Ulf; Ericsson, Anders; Samuelsson, Sten; Vaage, Jarle

    2005-10-01

    To investigate the influence of cardiopulmonary bypass on pulmonary hemodynamics and gas exchange. Low risk patients admitted for elective coronary artery bypass grafting were randomized to either on (n=25) or off pump (n=25) surgery. Central hemodynamics, gas exchange, and venous admixture were studied during and up to 20 h after surgery. There was no difference in pulmonary vascular resistance index (P=0.16), right ventricular stroke work index (P>0.2), mean pulmonary artery pressure (P>0.2) or pulmonary capillary wedge pressure (P>0.2) between groups. Soon after surgery there was a tendency towards higher cardiac index (P=0.07) in the off pump group. Arterial oxygen tension (P>0.2), hematocrit (P>0.2), venous admixture (P>0.2), and arterial-venous oxygen content difference (P=0.12) did not differ between groups. This prospective, randomized study showed no difference in pulmonary hemodynamics, pulmonary gas exchange, and venous admixture, in low risk patients undergoing off pump compared to on pump coronary artery bypass surgery.

  8. Prognostic value of gasometric parameters of carbon dioxide in resuscitation of septic patients. A bibliography review.

    Science.gov (United States)

    Lamsfus-Prieto, J Á; de Castro-Fernández, R; Hernández-García, A M; Marcano-Rodriguez, G

    2016-04-01

    The anaerobic metabolism is the cornerstone in physiopathology of septic shock. Nowadays we have both the central or mixed venous oxygen saturation and lactate levels to monitoring the metabolism in septic patients. Some studies have shown that normalization of systemic hemodynamic and oxygen metabolism variables not prevent progression to multiorgan damage and death. Recently has been proposed the venous-to-arterial carbon dioxide difference (ΔpvaCO2) as an alternative marker of tissue hypoperfusion, like Cardiac Index. High ΔpvaCO2 predicts adverse outcomes. Also has been proposed both, the ratio between the ΔpvaCO2 and arterial-to-venous oxygen content difference (ΔCavO2): ΔpvaCO2/ΔCavO2; and, the ratio between venous-to-arterial carbon dioxide difference (ΔCvaCO2) and ΔCavO2: ΔCvaCO2/ΔCavO2, as markers of anaerobic metabolism. Both of high ratios are related to high levels of lactate and worse prognosis. Therefore in patients with sepsis the combination of markers of resuscitation could be important to improve the outcomes. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Venous and arterial thrombosis: Two aspects of the same disease?

    Directory of Open Access Journals (Sweden)

    Paolo Prandoni

    2009-01-01

    Full Text Available Paolo PrandoniDepartment of Cardiothoracic and Vascular Sciences, Thromboembolism Unit, University Hospital of Padua Padua, ItalyAbstract: An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice.Keywords: venous thromboembolism, deep vein thrombosis, pulmonary embolism, myocardial infarction, ischemic stroke, atherosclerosis

  10. Effects of oxygen content on the pinning energy and critical current in the granular (Hg, Re)-1223 superconductors

    International Nuclear Information System (INIS)

    Passos, C.A.C.; Orlando, M.T.D.; Fernandes, A.A.R.; Oliveira, F.D.C.; Simonetti, D.S.L.; Fardin, J.F.; Belich, H.; Ferreira, M.M.

    2005-01-01

    Hg 0.82 Re 0.18 Ba 2 Ca 2 Cu 3 O 8+d polycrystalline samples, with different oxygen content, were investigated by ac resistance measurements under different applied magnetic field (up to 3 A/m) and critical current measurements. The intergrain and intragrain regions have shown an improvement in the pinning energy and critical current density, as considering the precursor preparation with 10% of O 2 and 90% of Ar (optimal doped). In addition, the samples presented S-I-S junctions type as considering Ambegaokar-Baratoff theory

  11. Iliac Vein Interrogation Augments Venous Ulcer Healing in Patients Who Have Failed Standard Compression Therapy along with Pathological Venous Closure.

    Science.gov (United States)

    Mousa, Albeir Y; Broce, Mike; Yacoub, Michael; AbuRahma, Ali F

    2016-07-01

    Treatment of venous ulcers is demanding for patients, as well as clinicians, and the investigation of underlying venous hypertension is the cornerstone of therapy. We propose that occult iliac vein stenosis should be ruled out by iliac vein interrogation (IVI) in patients with advanced venous stasis. We conducted a systematic retrospective analysis of a consecutive series of patients who presented with CEAP (clinical, etiological, anatomical, and pathophysiological) 6 venous disease. All patients had great saphenous vein ablation, compressive treatment, wound care (including Unna boot compression), and perforator closure using ablation therapy. Iliac vein stenosis was defined as ≥50% stenosis in cross-sectional surface area on intravascular ultrasound. Primary outcomes include time of venous ulcer healing and/or measurable change in the Venous Clinical Severity Score. Twenty-two patients with CEAP 6 venous disease met the inclusion criteria (active ulcers >1.5 cm in diameter). The average age and body mass index were 62.2 ± 9.2 years and 41.7 ± 16.7, respectively. The majority were female (72.7%) with common comorbidities, such as hyperlipidemia (54.5%), hypertension (36.4%), and diabetes mellitus (27.3%). Twenty-nine ulcers with an average diameter of 3.4 ± 1.9 cm and a depth of 2.2 ± 0.5 mm were treated. The majority of the ulcers occurred on the left limb (n = 17, 58.6%). Average perforator venous reflux was 3.6 ± 0.8 sec, while common femoral reflux was 1.8 ± 1.6. The majority (n = 19, 64.5%) of the perforator veins were located at the base of the ulcer, while the remainder (n = 10, 34.5%) were within 2 cm from the base. Of the 13 patients who underwent IVI, 8 patients (61.5%) had stenosis >50% that was corrected with iliac vein angioplasty and stenting (IVAS). There was a strong trend toward shorter healing time in the IVI group (7.9 ± 9.5 weeks) than for patients in the no iliac vein interrogation (NIVI) group (20.2 ± 15

  12. Deep venous thrombosis like puerperium complication: two cases

    International Nuclear Information System (INIS)

    Martin Gomez, J.I.; Larena Iturbe, J.A.; Zuazo Ojeda, M.A.; Pena Sarnago, J.M.

    1994-01-01

    Deep venous thrombosis, especially that of the ovarian vein, is a rare, potentially fatal complication that can present during the puerperium, its clinical diagnosis is not easy, thus dangerously delaying specific treatment. Two cases are presented of deep venous thrombosis diagnosed on the basis of computerized tomography (CT) in puerperal patients with symptoms of postpartum pain and fever. (Author) 9 refs

  13. Effect of mechanical ventilation on systemic oxygen extraction and lactic acidosis during early septic shock in rats.

    Science.gov (United States)

    Griffel, M I; Astiz, M E; Rackow, E C; Weil, M H

    1990-01-01

    We studied the effect of mechanical ventilation on systemic oxygen extraction and lactic acidosis in peritonitis and shock in rats. Sepsis was induced by cecal ligation and perforation. After tracheostomy, rats were randomized to spontaneous breathing (S) or mechanical ventilation with paralysis (V). Five animals were studied in each group. The V animals were paralyzed with pancuronium bromide to eliminate respiratory effort. Mechanical ventilation consisted of controlled ventilation using a rodent respirator with periodic adjustment of minute ventilation to maintain PaCO2 and pH within normal range. Arterial and central venous blood gases and thermodilution cardiac output were measured at baseline before abdominal surgery, and sequentially at 0.5, 3.5, and 6 h after surgery. At 6 h, cardiac output was 193 +/- 30 ml/kg.min in S animals and 199 +/- 32 ml/kg.min in V animals (NS). The central venous oxygen saturation was 27.4 +/- 4.7% in S animals and 30.0 +/- 6.4% in V animals (NS). Systemic oxygen extraction was 70 +/- 5% in S animals and 67 +/- 6% in V animals (NS). Arterial lactate was 2.4 +/- 0.4 mmol/L in S animals and 2.2 +/- 0.5 mmol/L in V animals (NS). The S animals developed lethal hypotension at 6.6 +/- 0.4 h compared to 6.8 +/- 0.4 h in V animals (NS). These data suggest that mechanical ventilation does not decrease systemic oxygen extraction or ameliorate the development of lactic acidosis during septic shock.

  14. Mixed Capillary Venous Retroperitoneal Hemangioma

    Directory of Open Access Journals (Sweden)

    Mohit Godar

    2013-01-01

    Full Text Available We report a case of mixed capillary venous hemangioma of the retroperitoneum in a 61-year-old man. Abdominal ultrasonography showed a mass to be hypoechoic with increased flow in color Doppler imaging. Dynamic contrast-enhanced computed tomography revealed a centripetal filling-in of the mass, located anterior to the left psoas muscle at the level of sacroiliac joint. On the basis of imaging features, preoperative diagnosis of hemangioma was considered and the mass was excised by laparoscopic method. Immunohistochemical studies were strongly positive for CD31 and CD34, and negative for calretinin, EMA, WT1, HMB45, Ki67, synaptophysin, and lymphatic endothelial cell marker D2–40. Histologically, the neoplasm was diagnosed as mixed capillary venous hemangioma.

  15. rCBF measurement by one-point venous sampling with the ARG method

    International Nuclear Information System (INIS)

    Yoshida, Nobuhiro; Okamoto, Toshiaki; Takahashi, Hidekado; Hattori, Teruo

    1997-01-01

    We investigated the possibility of using venous blood sampling instead of arterial blood sampling for the current method of ARG (autoradiography) used to determine regional cerebral blood flow (rCBF) on the basis of one session of arterial blood sampling and SPECT. For this purpose, the ratio of the arterial blood radioactivity count to the venous blood radioactivity count, the coefficient of variation, and the correlation and differences between arterial blood-based rCBF and venous blood-based rCBF were analyzed. The coefficient of variation was lowest (4.1%) 20 minutes after injection into the dorsum manus. When the relationship between venous and arterial blood counts was analyzed, arterial blood counts correlated well with venous blood counts collected at the dorsum manus 20 or 30 minutes after intravenous injection and with venous blood counts collected at the wrist 20 minutes after intravenous injection (r=0.97 or higher). The difference from rCBF determined on the basis of arterial blood was smallest (0.7) for rCBF determined on the basis of venous blood collected at the dorsum manus 20 minutes after intravenous injection. (author)

  16. Regular sports activities decrease the risk of venous thrombosis

    NARCIS (Netherlands)

    van Stralen, K. J.; le Cessie, S.; Rosendaal, F. R.; Doggen, C. J. M.

    2007-01-01

    BACKGROUND: Stasis of the blood has been postulated as a major cause of venous thrombosis. However, little is known about the effect of stimulating the blood flow in order to prevent venous thrombosis through, for example, sports activities. OBJECTIVES: In a large population-based case-control study

  17. Noncontrast computed tomographic Hounsfield unit evaluation of cerebral venous thrombosis: a quantitative evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Besachio, David A. [University of Utah, Department of Radiology, Salt Lake City (United States); United States Navy, Bethesda, MD (United States); Quigley, Edward P.; Shah, Lubdha M.; Salzman, Karen L. [University of Utah, Department of Radiology, Salt Lake City (United States)

    2013-08-15

    Our objective is to determine the utility of noncontrast Hounsfield unit values, Hounsfield unit values corrected for the patient's hematocrit, and venoarterial Hounsfield unit difference measurements in the identification of intracranial venous thrombosis on noncontrast head computed tomography. We retrospectively reviewed noncontrast head computed tomography exams performed in both normal patients and those with cerebral venous thrombosis, acquiring Hounsfield unit values in normal and thrombosed cerebral venous structures. Also, we acquired Hounsfield unit values in the internal carotid artery for comparison to thrombosed and nonthrombosed venous structures and compared the venous Hounsfield unit values to the patient's hematocrit. A significant difference is identified between Hounsfield unit values in thrombosed and nonthrombosed venous structures. Applying Hounsfield unit threshold values of greater than 65, a Hounsfield unit to hematocrit ratio of greater than 1.7, and venoarterial difference values greater than 15 alone and in combination, the majority of cases of venous thrombosis are identifiable on noncontrast head computed tomography. Absolute Hounsfield unit values, Hounsfield unit to hematocrit ratios, and venoarterial Hounsfield unit value differences are a useful adjunct in noncontrast head computed tomographic evaluation of cerebral venous thrombosis. (orig.)

  18. Noncontrast computed tomographic Hounsfield unit evaluation of cerebral venous thrombosis: a quantitative evaluation

    International Nuclear Information System (INIS)

    Besachio, David A.; Quigley, Edward P.; Shah, Lubdha M.; Salzman, Karen L.

    2013-01-01

    Our objective is to determine the utility of noncontrast Hounsfield unit values, Hounsfield unit values corrected for the patient's hematocrit, and venoarterial Hounsfield unit difference measurements in the identification of intracranial venous thrombosis on noncontrast head computed tomography. We retrospectively reviewed noncontrast head computed tomography exams performed in both normal patients and those with cerebral venous thrombosis, acquiring Hounsfield unit values in normal and thrombosed cerebral venous structures. Also, we acquired Hounsfield unit values in the internal carotid artery for comparison to thrombosed and nonthrombosed venous structures and compared the venous Hounsfield unit values to the patient's hematocrit. A significant difference is identified between Hounsfield unit values in thrombosed and nonthrombosed venous structures. Applying Hounsfield unit threshold values of greater than 65, a Hounsfield unit to hematocrit ratio of greater than 1.7, and venoarterial difference values greater than 15 alone and in combination, the majority of cases of venous thrombosis are identifiable on noncontrast head computed tomography. Absolute Hounsfield unit values, Hounsfield unit to hematocrit ratios, and venoarterial Hounsfield unit value differences are a useful adjunct in noncontrast head computed tomographic evaluation of cerebral venous thrombosis. (orig.)

  19. [Sequelae of unilateral deep venous thrombosis in plethysmography of the calf].

    Science.gov (United States)

    Zicot, M; Depairon, M

    1982-01-01

    Twenty four patients suffering from unilateral venous disturbances revealed by Doppler and secondary to a deep venous thrombosis were examined. The calf venous haemodynamics was analyzed by use of a strain-jauge plethysmograph. We determined the increase in venous volume due to the inflation of a thigh pneumatic cuff (pressure at 20, 40 and 60 mm Hg; delta V20, delta V40, delta V60). The maximal venous output (Vout) was measured after a quick release of the 60 mm Hg pressure. The maximal venous drainage (VMM) was assessed during a rhythmic exercise (tiptoeing) while standing; delta V20, delta V40 and delta V60 were nearly constantly reduced on the abnormal side (t of Student respectively 3.49; 6.09 and 5.07). Vout dropped proportionaly to delta V60. Some abnormalities due to valvular insufficiency were frequently present in the beginning of the inflation curve at the level of the abnormal limbs. VMM was nearly always largely decreased on the affected side (t = 5.43). The unilateral flow disturbances displayed by the Doppler were regularly going with abnormalities of the capacitive system, well demonstrated by comparison with the non-affected limbs.

  20. The surgical treatment of ilio-femoral venous obstruction.

    Science.gov (United States)

    Illuminati, G; Caliò, F G; D'Urso, A; Mancini, P; Papaspyropoulos, V; Ceccanei, G; Lorusso, R; Vietri, F

    2004-01-01

    A series of 9 patients of a mean age of 48 years, operated on for compression of the ilio-femoral venous axis is reported. The cause of obstruction was external compression in 3 cases, a retroperitoneal sarcoma in 1 case, and an infrarenal aortic aneurysm in 2. Two patients presented with a Cockett's syndrome, 3 with a chronic ilio-femoral thrombosis, and one with a post-traumatic segmentary stenosis. Treatment consisted in a resection/Dacron grafting of 2 infrarenal aortic aneurysms, one femoro-caval bypass graft, 2 transpositions of the right common iliac artery in the left hypogastric artery for Cockett's syndrome, 3 Palma's operations for chronic thrombosis, and one internal jugular vein interposition for segmentary stenosis. There were no postoperative deaths and no early thromboses of venous reconstructions performed. All the patients were relieved of symptoms during the follow-up period, whose mean length was 38 months. The cause of venous obstruction and the presence of symptoms which are resistant to medical treatment are the main indications to ilio-femoral venous revascularization. The choice of the optimal treatment in each single case yields satisfactory results.