WorldWideScience

Sample records for arterial partial pressure

  1. Arterial oxygen partial pressures reduce the insulin-dependent induction of the perivenously located glucokinase in rat hepatocyte cultures: mimicry of arterial oxygen pressures by H2O2.

    OpenAIRE

    Kietzmann, T; Roth, U; Freimann, S; Jungermann, K

    1997-01-01

    Liver glucokinase (GK) is localized predominantly in the perivenous zone. GK mRNA was induced by insulin maximally under venous O2 partial pressure (pO2) and only half-maximally under arterial pO2. CoCl2 and desferrioxamine mimicked venous pO2 and enhanced the insulin-dependent induction of GK mRNA under arterial pO2. H2O2 mimicked arterial pO2 and reduced insulin-induced GK mRNA under venous pO2 to the lower arterial levels. Thus the zonal O2 gradient in liver seems to have a key role in the...

  2. Decline in arterial partial pressure of oxygen after exercise: a surrogate marker of pulmonary vascular obstructive disease in patients with atrial septal defect and severe pulmonary hypertension.

    Science.gov (United States)

    Laksmivenkateshiah, Srinivas; Singhi, Anil K; Vaidyanathan, Balu; Francis, Edwin; Karimassery, Sundaram R; Kumar, Raman K

    2011-06-01

    To examine the utility of decline in arterial partial pressure of oxygen after exercise as a marker of pulmonary vascular obstructive disease in patients with atrial septal defect and pulmonary hypertension. Treadmill exercise was performed in 18 patients with atrial septal defect and pulmonary hypertension. Arterial blood gas samples were obtained before and after peak exercise. A decline in the arterial pressure of oxygen of more than 10 millimetres of mercury after exercise was considered significant based on preliminary tests conducted on the controls. Cardiac catheterisation was performed in all patients and haemodynamic data sets were obtained on room air, oxygen, and a mixture of oxygen and nitric oxide (30-40 parts per million). There were 10 patients who had more than a 10 millimetres of mercury drop in arterial partial pressure of oxygen after exercise and who had a basal pulmonary vascular resistance index of more than 7 Wood units per square metre. Out of eight patients who had less than a 10 millimetres of mercury drop in arterial partial pressure of oxygen after exercise, seven had a basal pulmonary vascular resistance index of less than 7 Wood units per square metre, p equals 0.0001. A decline in arterial partial pressure of oxygen of more than 10 millimetres of mercury predicted a basal pulmonary vascular resistance index of more than 7 Wood units per square metre with a specificity of 100% and a sensitivity of 90%. A decline in arterial partial pressure of oxygen following exercise appears to predict a high pulmonary vascular resistance index in patients with atrial septal defect and pulmonary hypertension. This test is a useful non-invasive marker of pulmonary vascular obstructive disease in this subset.

  3. Association between administered oxygen, arterial partial oxygen pressure and mortality in mechanically ventilated intensive care unit patients

    NARCIS (Netherlands)

    de Jonge, Evert; Peelen, Linda; Keijzers, Peter J.; Joore, Hans; de Lange, Dylan; van der Voort, Peter Hj; Bosman, Robert J.; de Waal, Ruud Al; Wesselink, Ronald; de Keizer, Nicolette F.

    2008-01-01

    Introduction The aim of this study was to investigate whether in-hospital mortality was associated with the administered fraction of oxygen in inspired air (FiO(2)) and achieved arterial partial pressure of oxygen (PaO2). Methods This was a retrospective, observational study on data from the first

  4. Association between administered oxygen, arterial partial oxygen pressure and mortality in mechanically ventilated intensive care unit patients

    NARCIS (Netherlands)

    de Jonge, Evert; Peelen, Linda; Keijzers, Peter J.; Joore, Hans; de Lange, Dylan; van der Voort, Peter H. J.; Bosman, Robert J.; de Waal, Ruud A. L.; Wesselink, Ronald; de Keizer, Nicolette F.

    2008-01-01

    Introduction The aim of this study was to investigate whether in-hospital mortality was associated with the administered fraction of oxygen in inspired air (FiO(2)) and achieved arterial partial pressure of oxygen (PaO(2)). Methods This was a retrospective, observational study on data from the first

  5. Classifying Acute Respiratory Distress Syndrome Severity: Correcting the Arterial Oxygen Partial Pressure to Fractional Inspired Oxygen at Altitude.

    Science.gov (United States)

    Pérez-Padilla, Rogelio; Hernández-Cárdenas, Carmen Margarita; Lugo-Goytia, Gustavo

    2016-01-01

    In the well-known Berlin definition of acute respiratory distress syndrome (ARDS), there is a recommended adjustment for arterial oxygen partial pressure to fractional inspired oxygen (PaO2/FIO2) at altitude, but without a reference as to how it was derived.

  6. Increasing arterial oxygen partial pressure during cardiopulmonary resuscitation is associated with improved rates of hospital admission.

    Science.gov (United States)

    Spindelboeck, Walter; Schindler, Otmar; Moser, Adrian; Hausler, Florian; Wallner, Simon; Strasser, Christa; Haas, Josef; Gemes, Geza; Prause, Gerhard

    2013-06-01

    As recent clinical data suggest a harmful effect of arterial hyperoxia on patients after resuscitation from cardiac arrest (CA), we aimed to investigate this association during cardiopulmonary resuscitation (CPR), the earliest and one of the most crucial phases of recirculation. We analysed 1015 patients who from 2003 to 2010 underwent out-of-hospital CPR administered by emergency medical services serving 300,000 inhabitants. Inclusion criteria for further analysis were nontraumatic background of CA and patients >18 years of age. One hundred and forty-five arterial blood gas analyses including oxygen partial pressure (paO2) measurement were obtained during CPR. We observed a highly significant increase in hospital admission rates associated with increases in paO2 in steps of 100 mmHg (13.3 kPa). Subsequently, data were clustered according to previously described cutoffs (≤ 60 mmHg [8 kPa

  7. [Correlation between the inspired fraction of oxygen, maternal partial oxygen pressure, and fetal partial oxygen pressure during cesarean section of normal pregnancies].

    Science.gov (United States)

    Castro, Carlos Henrique Viana de; Cruvinel, Marcos Guilherme Cunha; Carneiro, Fabiano Soares; Silva, Yerkes Pereira; Cabral, Antônio Carlos Vieira; Bessa, Roberto Cardoso

    2009-01-01

    Despite changes in pulmonary function, maternal oxygenation is maintained during obstetric regional blocks. But in those situations, the administration of supplementary oxygen to parturients is a common practice. Good fetal oxygenation is the main justification; however, this has not been proven. The objective of this randomized, prospective study was to test the hypothesis of whether maternal hyperoxia is correlated with an increase in fetal gasometric parameters in elective cesarean sections. Arterial blood gases of 20 parturients undergoing spinal block with different inspired fractions of oxygen were evaluated and correlated with fetal arterial blood gases. An increase in maternal inspired fraction of oxygen did not show any correlation with an increase of fetal partial oxygen pressure. Induction of maternal hyperoxia by the administration of supplementary oxygen did not increase fetal partial oxygen pressure. Fetal gasometric parameters did not change even when maternal parameters changed, induced by hyperoxia, during cesarean section under spinal block.

  8. Correlation of femoral artery vs radial artery pressures with central pressure after cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Yaseen, R.; Memon, H.

    2008-01-01

    To assess the effectiveness of femoral and radial arterial lines on the correlation of peripheral and central mean arterial blood pressure in children after discontinuation of cardiopulmonary bypass. Fifty children scheduled for cardiac surgery with cardiopulmonary bypass were included in the study. After approval from the hospital ethics committee and informed consent. 50 children undergoing cardiac surgical procedures with cardiopulmonary bypass were randomly assigned to two different groups. In Group- A (RAP, n-2) a radial arterial line and in Group-B (FAP, n-25) a femoral arterial line was used to monitor the blood pressure. Simultaneous mean peripheral arterial pressure and mean central aortic pressure were recorded before cardiopulmonary bypass and 5 mins after separation from the cardiopulmonary bypass. The correlation of mean peripheral arterial pressure (radial and femoral) versus mean aortic pressure were compared. The data was recorded as Mean +- SD and P-value. The ages of children ranged from 4-12 years and their weight from 14.1-28.5 kg. In all of them following cardiopulmonary bypass, aortic pressure correlates better with femoral arterial pressure (p<0.001). The radial arterial line readings under estimated central aortic pressure when compared to femoral arterial line readings. Aortic pressure readings correlate better with femoral arterial pressure than radial arterial pressure in children. (author)

  9. A common humoral background of intraocular and arterial blood pressure dysregulation.

    Science.gov (United States)

    Skrzypecki, Janusz; Grabska-Liberek, Iwona; Przybek, Joanna; Ufnal, Marcin

    2018-03-01

    It has been postulated that intraocular pressure, an important glaucoma risk factor, correlates positively with arterial blood pressure (blood pressure). However, results of experimental and clinical studies are often contradictory. It is hypothesized that, in some hypertensive patients, disturbances in intraocular pressure regulation may depend on biological effects of blood borne hormones underlying a particular type of hypertension, rather than on blood pressure level itself. This review compares the effects of hormones on blood pressure and intraocular pressure, in order to identify a hormonal profile of hypertensive patients with an increased risk of intraocular pressure surge. The PUBMED database was searched to identify pre-clinical and clinical studies investigating the role of angiotensin II, vasopressin, adrenaline, noradrenaline, prostaglandins, and gaseous transmitters in the regulation of blood pressure and intraocular pressure. Studies included in the review suggest that intraocular and blood pressures often follow a different pattern of response to the same hormone. For example, vasopressin increases blood pressure, but decreases intraocular pressure. In contrast, high level of nitric oxide decreases blood pressure, but increases intraocular pressure. Arterial hypertension is associated with altered levels of blood borne hormones. Contradicting results of studies on the relationship between arterial hypertension and intraocular pressure might be partially explained by diverse effects of hormones on arterial and intraocular pressures. Further studies are needed to evaluate if hormonal profiling may help to identify glaucoma-prone patients.

  10. [Correlation between end-tidal carbon dioxide and partial pressure of arterial carbon dioxide in ventilated newborns].

    Science.gov (United States)

    Feng, Jin-Xing; Liu, Xiao-Hong; Huang, Hui-Jun; Yu, Zhen-Zhu; Yang, Hui; He, Liu-Fang

    2014-05-01

    To study the correlation between end-tidal carbon dioxide (PetCO2) and partial pressure of arterial carbon dioxide (PaCO2) in ventilated newborns. Thirty-one ventilated newborn underwent mainstream PetCO2 monitoring; meanwhile, arterial blood gas analysis was performed. The correlation and consistency between PetCO2 and PaCO2 were assessed. A total of 85 end-tidal and arterial CO2 pairs were obtained from 31 ventilated newborns. The mean PetCO2 (41±10 mm Hg) was significantly lower than the corresponding mean PaCO2 (46±11 mm Hg) (Plimits of consistency, -3.3 to 13.6 mmHg), and 5% (4/85) of the points were beyond the 95%CI. When the oxygenation index (OI) was less than 300 mm Hg (n=48), there was a significant positive correlation between PetCO2 and PaCO2 (r=0.85, Plimits of consistency, -2.6 to 14.5 mm Hg), and 4.2% (2/48) of the points were beyond the 95%CI. When the OI was more than 300 mm Hg (n=37), there was also a significant positive correlation between PetCO2 and PaCO2 (r=0.91, Plimits of consistency, -3.9 to 12.1 mm Hg), and 5% (2/37) of the points were beyond the 95%CI. There is a good correlation and consistency between PetCO2 and PaCO2 in ventilated newborns.

  11. Partial subclavian steal syndrome in a congenitally anomalous subclavian artery

    International Nuclear Information System (INIS)

    Krnic, A.; Sucic, Z.; Vucic, N.; Krolo, I.

    2006-01-01

    Background. A subclavian steal syndrome results from the abnormal flow of blood due to the occlusion in the subclavian artery proximal to the origin of the vertebral artery. A case of a male patient with a partial subclavian steal syndrome is presented. Case report. The syndrome was caused by a stenotic lesion of an aberrant right subclavian artery (the so called lusorian artery). The partial subclavian steal was recognized using the duplex ultrasound which showed the to and fro pattern in the right vertebral artery. Angiography of the aortic arch revealed the arterial anomaly. In our case, duplex ultrasound was a crucial method in diagnosing the partial subclavian steal syndrome. However, in order to show the arterial anomaly, the final evaluation had to be performed using arteriography. Conclusions. The early recognized partial subclavian steal syndrome provides good understanding of patient's symptoms, successful follow up, and a variety of treatment options. (author)

  12. Determinants of systemic zero-flow arterial pressure.

    Science.gov (United States)

    Brunner, M J; Greene, A S; Sagawa, K; Shoukas, A A

    1983-09-01

    Thirteen pentobarbital-anesthetized dogs whose carotid sinuses were isolated and perfused at a constant pressure were placed on total cardiac bypass. With systemic venous pressure held at 0 mmHg (condition 1), arterial inflow was stopped for 20 s at intrasinus pressures of 50, 125, and 200 mmHg. Zero-flow arterial pressures under condition 1 were 16.2 +/- 1.3 (SE), 13.8 +/- 1.1, and 12.5 +/- 0.8 mmHg, respectively. In condition 2, the venous outflow tube was clamped at the instant of stopping the inflow, causing venous pressure to rise. The zero-flow arterial pressures were 19.7 +/- 1.3, 18.5 +/- 1.4, and 16.4 +/- 1.2 mmHg for intrasinus pressures of 50, 125, and 200 mmHg, respectively. At all levels of intrasinus pressure, the zero-flow arterial pressure in condition 2 was higher (P less than 0.005) than in condition 1. In seven dogs, at an intrasinus pressure of 125 mmHg, epinephrine increased the zero-flow arterial pressure by 3.0 mmHg, whereas hexamethonium and papaverine decreased the zero-flow arterial pressure by 2 mmHg. Reductions in the hematocrit from 52 to 11% resulted in statistically significant changes (P less than 0.01) in zero-flow arterial pressures. Thus zero-flow arterial pressure was found to be affected by changes in venous pressure, hematocrit, and vasomotor tone. The evidence does not support the literally interpreted concept of the vascular waterfall as the model for the finite arteriovenous pressure difference at zero flow.

  13. The conundrum of arterial stiffness, elevated blood pressure, and aging.

    Science.gov (United States)

    AlGhatrif, Majd; Lakatta, Edward G

    2015-02-01

    Isolated systolic hypertension is a major health burden that is expanding with the aging of our population. There is evidence that central arterial stiffness contributes to the rise in systolic blood pressure (SBP); at the same time, central arterial stiffening is accelerated in patients with increased SBP. This bidirectional relationship created a controversy in the field on whether arterial stiffness leads to hypertension or vice versa. Given the profound interdependency of arterial stiffness and blood pressure, this question seems intrinsically challenging, or probably naïve. The aorta's function of dampening the pulsatile flow generated by the left ventricle is optimal within a physiological range of distending pressure that secures the required distal flow, keeps the aorta in an optimal mechanical conformation, and minimizes cardiac work. This homeostasis is disturbed by age-associated, minute alterations in aortic hemodynamic and mechanical properties that induce short- and long-term alterations in each other. Hence, it is impossible to detect an "initial insult" at an epidemiological level. Earlier manifestations of these alterations are observed in young adulthood with a sharp decline in aortic strain and distensibility accompanied by an increase in diastolic blood pressure. Subsequently, aortic mechanical reserve is exhausted, and aortic remodeling with wall stiffening and dilatation ensue. These two phenomena affect pulse pressure in opposite directions and different magnitudes. With early remodeling, there is an increase in pulse pressure, due to the dominance of arterial wall stiffness, which in turn accelerates aortic wall stiffness and dilation. With advanced remodeling, which appears to be greater in men, the effect of diameter becomes more pronounced and partially offsets the effect of wall stiffness leading to plateauing in pulse pressure in men and slower increase in pulse pressure (PP) than that of wall stiffness in women. The complex nature of

  14. Transmission of arterial oxygen partial pressure oscillations to the cerebral microcirculation in a porcine model of acute lung injury caused by cyclic recruitment and derecruitment.

    Science.gov (United States)

    Klein, K U; Boehme, S; Hartmann, E K; Szczyrba, M; Heylen, L; Liu, T; David, M; Werner, C; Markstaller, K; Engelhard, K

    2013-02-01

    Cyclic recruitment and derecruitment (R/D) play a key role in the pathomechanism of acute lung injury (ALI) leading to respiration-dependent oscillations of arterial partial pressure of oxygen (Pa(O(2))). These Pa(O(2)) oscillations could also be forwarded to the cerebral microcirculation. In 12 pigs, partial pressure of oxygen was measured in the thoracic aorta (Pa(O(2))) and subcortical cerebral tissue (Pbr(O(2))). Cerebral cortical haemoglobin oxygen saturation (Sbr(O(2))), cerebral blood flow (CBF), and peripheral haemoglobin saturation (Sp(O(2))) were assessed by spectroscopy and laser Doppler flowmetry. Measurements at different fractions of inspired oxygen (F(I(O(2)))) were performed at baseline and during cyclic R/D. frequency domain analysis, the Mann-Whitney test, linear models to test the influence of Pa(O(2)) and systolic arterial pressure (SAP) oscillations on cerebral measurements. Parameters [mean (SD)] remained stable during baseline. Pa(O(2)) oscillations [10.6 (8) kPa, phase(reference)], systemic arterial pressure (SAP) oscillations [20 (9) mm Hg, phase(Pa(O(2))-SAP) -33 (72)°], and Sp(O(2))oscillations [1.9 (1.7)%, phase(Pa(O(2))-Sp(O(2))) 264 (72)°] were detected during lung R/D at 1.0. Pa(O(2)) oscillations decreased [2.7 (3.5) kPa, P=0.0008] and Sp(O(2)) oscillations increased [6.8 (3.9)%, P=0.0014] at F(I(O(2))) 0.3. In the brain, synchronized Pbr(O(2)) oscillations [0.6 (0.4) kPa, phase(Pa(O(2))-Pbr(O(2))) 90 (39)°], Sbr(O(2)) oscillations [4.1 (1.5)%, phase(Pa(O(2))-Sbr(O(2))) 182 (54)°], and CBF oscillations [198 (176) AU, phase(Pa(O(2))-CBF) 201 (63)°] occurred that were dependent on Pa(O(2)) and SAP oscillations. Pa(O(2)) oscillations caused by cyclic R/D are transmitted to the cerebral microcirculation in a porcine model of ALI. These cyclic oxygen alterations could play a role in the crosstalk of acute lung and brain injury.

  15. Pressure drop and arterial compliance - Two arterial parameters in one measurement.

    Science.gov (United States)

    Rotman, Oren M; Zaretsky, Uri; Shitzer, Avraham; Einav, Shmuel

    2017-01-04

    Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from the pressure measurement system. The investigation was performed using numerical fluid-structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to fractional flow reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. The Relationship Between Oxygen Reserve Index and Arterial Partial Pressure of Oxygen During Surgery.

    Science.gov (United States)

    Applegate, Richard L; Dorotta, Ihab L; Wells, Briana; Juma, David; Applegate, Patricia M

    2016-09-01

    The use of intraoperative pulse oximetry (SpO2) enhances hypoxia detection and is associated with fewer perioperative hypoxic events. However, SpO2 may be reported as 98% when arterial partial pressure of oxygen (PaO2) is as low as 70 mm Hg. Therefore, SpO2 may not provide advance warning of falling arterial oxygenation until PaO2 approaches this level. Multiwave pulse co-oximetry can provide a calculated oxygen reserve index (ORI) that may add to information from pulse oximetry when SpO2 is >98%. This study evaluates the ORI to PaO2 relationship during surgery. We studied patients undergoing scheduled surgery in which arterial catheterization and intraoperative arterial blood gas analysis were planned. Data from multiple pulse co-oximetry sensors on each patient were continuously collected and stored on a research computer. Regression analysis was used to compare ORI with PaO2 obtained from each arterial blood gas measurement and changes in ORI with changes in PaO2 from sequential measurements. Linear mixed-effects regression models for repeated measures were then used to account for within-subject correlation across the repeatedly measured PaO2 and ORI and for the unequal time intervals of PaO2 determination over elapsed surgical time. Regression plots were inspected for ORI values corresponding to PaO2 of 100 and 150 mm Hg. ORI and PaO2 were compared using mixed-effects models with a subject-specific random intercept. ORI values and PaO2 measurements were obtained from intraoperative data collected from 106 patients. Regression analysis showed that the ORI to PaO2 relationship was stronger for PaO2 to 240 mm Hg (r = 0.536) than for PaO2 over 240 mm Hg (r = 0.0016). Measured PaO2 was ≥100 mm Hg for all ORI over 0.24. Measured PaO2 was ≥150 mm Hg in 96.6% of samples when ORI was over 0.55. A random intercept variance component linear mixed-effects model for repeated measures indicated that PaO2 was significantly related to ORI (β[95% confidence interval] = 0

  17. Relationship between arterial partial oxygen pressure after resuscitation from cardiac arrest and mortality in children.

    Science.gov (United States)

    Ferguson, Lee P; Durward, Andrew; Tibby, Shane M

    2012-07-17

    Observational studies in adults have shown a worse outcome associated with hyperoxia after resuscitation from cardiac arrest. Extrapolating from adult data, current pediatric resuscitation guidelines recommend avoiding hyperoxia. We investigated the relationship between arterial partial oxygen pressure and survival in patients admitted to the pediatric intensive care unit (PICU) after cardiac arrest. We conducted a retrospective cohort study using the Pediatric Intensive Care Audit Network (PICANet) database between 2003 and 2010 (n=122,521). Patients aged oxygen status and outcome was modeled with logistic regression, with nonlinearities explored via multivariable fractional polynomials. Covariates included age, sex, ethnicity, congenital heart disease, out-of-hospital arrest, year, Pediatric Index of Mortality-2 (PIM2) mortality risk, and organ supportive therapies. Of 1875 patients, 735 (39%) died in PICU. Based on the first arterial gas, 207 patients (11%) had hyperoxia (Pa(O)(2) ≥300 mm Hg) and 448 (24%) had hypoxia (Pa(O)(2) <60 mm Hg). We found a significant nonlinear relationship between Pa(O)(2) and PICU mortality. After covariate adjustment, risk of death increased sharply with increasing hypoxia (odds ratio, 1.92; 95% confidence interval, 1.80-2.21 at Pa(O)(2) of 23 mm Hg). There was also an association with increasing hyperoxia, although not as dramatic as that for hypoxia (odds ratio, 1.25; 95% confidence interval, 1.17-1.37 at 600 mm Hg). We observed an increasing mortality risk with advancing age, which was more pronounced in the presence of congenital heart disease. Both severe hypoxia and, to a lesser extent, hyperoxia are associated with an increased risk of death after PICU admission after cardiac arrest.

  18. Arterial pressure profile in patients with cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens H; Fuglsang, Stefan; Bendtsen, Flemming

    2012-01-01

    Patients with cirrhosis have cardiovascular dysfunction and altered mechanical properties of large and small arteries. This study was undertaken in order to analyze the arterial pressure curve in relation to mean arterial pressure level, stroke volume, and severity of liver disease....

  19. Computer model analysis of the radial artery pressure waveform.

    Science.gov (United States)

    Schwid, H A; Taylor, L A; Smith, N T

    1987-10-01

    Simultaneous measurements of aortic and radial artery pressures are reviewed, and a model of the cardiovascular system is presented. The model is based on resonant networks for the aorta and axillo-brachial-radial arterial system. The model chosen is a simple one, in order to make interpretation of the observed relationships clear. Despite its simplicity, the model produces realistic aortic and radial artery pressure waveforms. It demonstrates that the resonant properties of the arterial wall significantly alter the pressure waveform as it is propagated from the aorta to the radial artery. Although the mean and end-diastolic radial pressures are usually accurate estimates of the corresponding aortic pressures, the systolic pressure at the radial artery is often much higher than that of the aorta due to overshoot caused by the resonant behavior of the radial artery. The radial artery dicrotic notch is predominantly dependent on the axillo-brachial-radial arterial wall properties, rather than on the aortic valve or peripheral resistance. Hence the use of the radial artery dicrotic notch as an estimate of end systole is unreliable. The rate of systolic upstroke, dP/dt, of the radial artery waveform is a function of many factors, making it difficult to interpret. The radial artery waveform usually provides accurate estimates for mean and diastolic aortic pressures; for all other measurements it is an inadequate substitute for the aortic pressure waveform. In the presence of low forearm peripheral resistance the mean radial artery pressure may significantly underestimate the mean aortic pressure, as explained by a voltage divider model.

  20. Plateau Waves of Intracranial Pressure and Partial Pressure of Cerebral Oxygen.

    Science.gov (United States)

    Lang, Erhard W; Kasprowicz, Magdalena; Smielewski, Peter; Pickard, John; Czosnyka, Marek

    2016-01-01

    This study investigates 55 intracranial pressure (ICP) plateau waves recorded in 20 patients after severe traumatic brain injury (TBI) with a focus on a moving correlation coefficient between mean arterial pressure (ABP) and ICP, called PRx, which serves as a marker of cerebrovascular reactivity, and a moving correlation coefficient between ABP and cerebral partial pressure of oxygen (pbtO2), called ORx, which serves as a marker for cerebral oxygen reactivity. ICP and ICPamplitude increased significantly during the plateau waves, whereas CPP and pbtO2 decreased significantly. ABP, ABP amplitude, and heart rate remained unchanged. In 73 % of plateau waves PRx increased during the wave. ORx showed an increase during and a decrease after the plateau waves, which was not statistically significant. Our data show profound cerebral vasoparalysis on top of the wave and, to a lesser extent, impairment of cerebral oxygen reactivity. The different behavior of the indices may be due to the different latencies of the cerebral blood flow and oxygen level control mechanisms. While cerebrovascular reactivity is a rapidly reacting mechanism, cerebral oxygen reactivity is slower.

  1. Neonatal oxidative stress depends on oxygen blood pressure in umbilical artery.

    Science.gov (United States)

    Proietti, F; De Bernardo, G; Longini, M; Sordino, D; Scaramuzzini, G; Tataranno, M L; Belvisi, E; Bazzini, F; Perrone, S; Buonocore, G

    2016-01-01

    With advancing gestation, partial pressure of oxygen (pO2) and pH fall significantly. Hypoxia is a main factor inducing free radical generation and thereby oxidative stress (OS). Placental and fetal tissue response when oxygen becomes restricted is complex and partially known. We tested the hypothesis that changes in umbilical artery and vein blood gas concentrations modulate OS occurrence in the newborn. Seventy umbilical artery and vein plasma samples were collected from healthy term newborns immediately after delivery. F2 Isoprostanes (F2-Isop) were measured in all samples as reliable markers of lipid peroxidation. Significantly lower pCO2 and higher pO2 and pH were found in umbilical vein than in artery, as expected. A positive correlation was detected between pH and pO2 only in umbilical artery (p=0.019). F2-Isop levels were no different between artery and vein in cord blood. Significant correlations were found between F2-Isop and pCO2 (p=0.025) as well as between F2-Isop and pH in umbilical vein (p=0.027). F2-Isop correlated with pCO2 (p=0.007) as well as with pO2 values (p=0.005) in umbilical artery blood. Oxidative stress (OS) in newborns depends on oxygen concentrations in umbilical artery. OS biomarkers significantly correlate with pO2 and in umbilical artery but not in umbilical vein. In normoxic conditions fetal-maternal gas exchanges occurring in placenta re-establish normal higher oxygen levels in umbilical vein than artery, with a normal production of free radicals without any deleterious effects.

  2. Comparison of partial and complete arterial occlusion models for studying intestinal ischemia

    International Nuclear Information System (INIS)

    Parks, D.A.; Grogaard, B.; Granger, D.N.

    1982-01-01

    Mucosal albumin clearance was measured in jejunal segments of dogs under control conditions and following complete or partial arterial occlusion of varying durations (1, 2, 3, or 4 hours). The rate of albumin clearance was estimated from the luminal perfusion rate and the activity of protein bound 125 I in the perfusate and plasma. Partial and total arterial occlusions of 60 minutes to 4 hours' duration produced significant increases in mucosal albumin clearance. The magnitude of the rise in albumin clearance was directly related to the duration of ischemia in both total and partial arterial occlusion models. However, the magnitude of the increase in albumin clearance was significantly greater with total arterial occlusion for any given duration of ischemia. The albumin clearance results obtained in the present study compare favorably with previously reported morphologic changes in the intestinal mucosa produced by both total and partial occlusion of the superior mesenteric artery. The agreement between morphologic and physiologic measurements indicates that mucosal albumin clearance may be a useful tool for studying the pathophysiology of intestinal ischemia

  3. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.

  4. Estimation of vapour pressure and partial pressure of subliming ...

    Indian Academy of Sciences (India)

    Administrator

    conditions of (total) pressure by using thermogravimetry under those conditions. Further, from the partial pressure P, it is possible to determine the number of moles of material in the vapour phase using the ideal gas equation, PV = nRT, where P is the partial pressure, V the volume, n number of moles (of the vapour), R the ...

  5. Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.

    Science.gov (United States)

    Collins, Julie-Ann; Rudenski, Aram; Gibson, John; Howard, Luke; O'Driscoll, Ronan

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (S O2 ) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin-oxygen dissociation curve, a graphical representation of the relationship between oxygen satur-ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the S O2 in blood from patients with normal pH and S O2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (S pO2 ) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (S aO2 ) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable S pO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  6. Relating oxygen partial pressure, saturation and content: the haemoglobin–oxygen dissociation curve

    Directory of Open Access Journals (Sweden)

    Julie-Ann Collins

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content, saturation (SO2 and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin–oxygen dissociation curve, a graphical representation of the relationship between oxygen satur­ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the SO2 in blood from patients with normal pH and SO2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (SpO2 is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (SaO2 as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable SpO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  7. Arterial pressure measurement: Is the envelope curve of the oscillometric method influenced by arterial stiffness?

    International Nuclear Information System (INIS)

    Gelido, G; Angiletta, S; Pujalte, A; Quiroga, P; Cornes, P; Craiem, D

    2007-01-01

    Measurement of peripheral arterial pressure using the oscillometric method is commonly used by professionals as well as by patients in their homes. This non invasive automatic method is fast, efficient and the required equipment is affordable with a low cost. The measurement method consists of obtaining parameters from a calibrated decreasing curve that is modulated by heart beats witch appear when arterial pressure reaches the cuff pressure. Diastolic, mean and systolic pressures are obtained calculating particular instants from the heart beats envelope curve. In this article we analyze the envelope of this amplified curve to find out if its morphology is related to arterial stiffness in patients. We found, in 33 volunteers, that the envelope waveform width correlates to systolic pressure (r=0.4, p<0.05), to pulse pressure (r=0.6, p<0.05) and to pulse pressure normalized to systolic pressure (r=0.6, p<0.05). We believe that the morphology of the heart beats envelope curve obtained with the oscillometric method for peripheral pressure measurement depends on arterial stiffness and can be used to enhance pressure measurements

  8. [Pedicled superior gluteal artery perforator bilateral quadrilobed flaps for repair of large sacrococcygeal pressure sores].

    Science.gov (United States)

    Hai, Henglin; Li, Huatao; Chen, Yang; Li, Qiang; Wu, Shenggang; Lili, Wang; Yan, Lei; Xiaoying, Zhou

    2013-03-01

    To investigate the effectiveness of pedicled superior gluteal artery perforator bilateral quadrilobed flaps for repairing large sacrococcygeal pressure sores. Between June 2003 and August 2011, 6 paraplegia patients with large sacrococcygeal pressure sores were repaired with the pedicled superior gluteal artery perforator bilateral quadrilobed flaps. There were 2 males and 4 females with an average age of 45.6 years (range, 37-62 years). The mean disease duration was 8.4 months (range, 3-26 months). According to National Pressure Ulcer Advisory Panel (NPUAP) standard, 6 cases rated as degree IV. The size of pressure sores ranged from 15 cm x 13 cm to 18 cm x 16 cm. The size of flaps ranged from 18 cm x 14 cm to 21 cm x 15 cm. After operation, all flaps survived successfully. The wounds healed by first intention in 5 cases; partial dehiscence of incision occurred in 1 case, which was cured after dressing change for 26 days. Six patients were followed up 6-24 months (mean, 12.5 months). The appearance and texture of the flaps were smooth and soft with good elasticity and no ulceration. Pedicled superior gluteal artery perforator bilateral quadrilobed flaps can repair large sacrococcygeal pressure sores. The appearance of flaps is smooth and has good compression-resistance effect.

  9. Partial thyroid arterial embolization for the treatment of hyperthyroidism

    International Nuclear Information System (INIS)

    Brzozowski, Krzysztof; Piasecki, Piotr; Zięcina, Piotr; Frankowska, Emilia; Jaroszuk, Andrzej; Kamiński, Grzegorz; Bogusławska-Walecka, Romana

    2012-01-01

    Background: Hyperactive thyroid gland in patients that are unable to tolerate or accept standard therapy is a common clinical problem. Aim of the study was to evaluate effectiveness of partial thyroid arterial embolization in patients with hyperthyroidism. Material/methods: From May 2004 to November 2005 partial thyroid gland embolization was performed in 15 patients. Mean thyroid gland volume was 162 ml. Embolization of one to three thyriod arteries was performed with the mixture of Histoacryl and Lipiodol. Selective angiography was performed after embolization to ensure that the targeted arteries were completely occluded. Follow-up study covered 12 patients. Results: The embolization procedure was well tolerated by all patients. Three days after embolization fT3 and fT4 levels were higher than before the procedure. Further laboratory tests showed quick reversal to near-normal or normal levels of thyroid hormones. 12 weeks follow-up showed: normal serum levels of fT3, fT4 and TSH in 9 of 12 patients (75%), hyperthyroidism in 3 of 12 patients (25%), goiter volume reduction of approximately 32% of its original volume (from 13 to 76.3%), mean thyroid gland volume of 94 ml. One year after embolization 7 of 12 patients required thyreostatic drugs. At two and four years follow-up thyreostatics doses were significantly lower and thyroid tissue was fibrotic. Conclusions: Based on our results the treatment of the thyroid gland goiters using arterial thyroid gland partial embolization may be offered as an effective alternative for patients who will not or cannot accept standard therapy.

  10. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  11. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  12. Choice of marker for assessment of RV dysfunction in acute pulmonary embolism : NT-proBNP, pulmonary artery systolic pressure, mean arterial pressure, or blood pressure index.

    Science.gov (United States)

    Ates, H; Ates, I; Kundi, H; Yilmaz, F M

    2017-12-01

    We aimed to examine the value of NT-proBNP, pulmonary artery systolic pressure (PASP), blood pressure index (BPI), and mean arterial pressure (MAP) in the determination of right ventricular dysfunction (RVD) in patients with acute pulmonary embolism (APE). A total of 547 patients diagnosed with APE were included in the study. Demographic characteristics and comorbid conditions of patients were recorded in patient files. For blood pressure measurement, a calibrated digital blood pressure monitor was used at regular intervals. Blood samples were taken from patients at the time of admission for hemogram, biochemical, and hemostasis blood tests. Echocardiography was performed on all patients to detect RVD and evaluate pulmonary artery pressure. PASP (p blood pressure (p blood cell (p AUC ± SE = 0.975 ± 0.006; p < 0.001) was found to be the best predictor of RVD with a higher sensitivity (92.8%) and specificity (100%). We found that BPI had a better diagnostic discrimination for RVD compared with PASP and NT-proBNP.

  13. Thin film devices used as oxygen partial pressure sensors

    Science.gov (United States)

    Canady, K. S.; Wortman, J. J.

    1970-01-01

    Electrical conductivity of zinc oxide films to be used in an oxygen partial pressure sensor is measured as a function of temperature, oxygen partial pressure, and other atmospheric constituents. Time response following partial pressure changes is studied as a function of temperature and environmental changes.

  14. Long-term facial artery catheter implantation for serial arterial blood sampling and invasive arterial blood pressure measurement in horses.

    Science.gov (United States)

    Dias, Deborah Penteado Martins; Teixeira, Luisa Gouvêa; Canola, Paulo Aléscio; Albernaz, Raquel Mincarelli; Marques, José Antônio; Neto, José Corrêa de Lacerda

    2012-06-01

    The purpose of this investigation was to evaluate surgical catheter implantation in the facial artery of horses and the long-term maintenance of such arteries using heparin and ascorbic acid as filling solution. Nine horses were implanted with a polyurethane catheter. The catheters were flushed with a heparin/ascorbic acid solution every 8h and remained patent for 25 days. Arterial blood samples were collected twice a day, and one exercise test that included serial blood samples and arterial pressure recordings was performed on a treadmill. Polyurethane catheters surgically implanted in the facial artery can be kept patent by filling with a heparin/ascorbic acid solution and provide convenient invasive arterial access in horses which is suitable for use for serial blood sampling and blood pressure recordings, even during exercise on treadmill. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  16. Mathematical Modelling of Intraretinal Oxygen Partial Pressure ...

    African Journals Online (AJOL)

    Purpose: The aim of our present work is to develop a simple steady state model for intraretinal oxygen partial pressure distribution and to investigate the effect of various model parameters on the partial pressure distribution under adapted conditions of light and darkness.. Method: A simple eight-layered mathematical model ...

  17. Thin film oxygen partial pressure sensor

    Science.gov (United States)

    Wortman, J. J.; Harrison, J. W.; Honbarrier, H. L.; Yen, J.

    1972-01-01

    The development is described of a laboratory model oxygen partial pressure sensor using a sputtered zinc oxide thin film. The film is operated at about 400 C through the use of a miniature silicon bar. Because of the unique resistance versus temperature relation of the silicon bar, control of the operational temperature is achieved by controlling the resistance. A circuit for accomplishing this is described. The response of sputtered zinc oxide films of various thicknesses to oxygen, nitrogen, argon, carbon dioxide, and water vapor caused a change in the film resistance. Over a large range, film conductance varied approximately as the square root of the oxygen partial pressure. The presence of water vapor in the gas stream caused a shift in the film conductance at a given oxygen partial pressure. A theoretical model is presented to explain the characteristic features of the zinc oxide response to oxygen.

  18. Impact of age on pulmonary artery systolic pressures at rest and with exercise

    Directory of Open Access Journals (Sweden)

    Garvan C Kane

    2016-06-01

    Full Text Available Aim: It is not well known if advancing age influences normal rest or exercise pulmonary artery pressures. The purpose of the study was to evaluate the association of increasing age with measurements of pulmonary artery systolic pressure at rest and with exercise. Subjects and methods: A total of 467 adults without cardiopulmonary disease and normal exercise capacity (age range: 18–85 years underwent symptom-limited treadmill exercise testing with Doppler measurement of rest and exercise pulmonary artery systolic pressure. Results: There was a progressive increase in rest and exercise pulmonary artery pressures with increasing age. Pulmonary artery systolic pressures at rest and with exercise were 25 ± 5 mmHg and 33 ± 9 mmHg, respectively, in those <40 years, and 30 ± 5 mmHg and 41 ± 12 mmHg, respectively, in those ≥70 years. While elevated left-sided cardiac filling pressures were excluded by protocol design, markers of arterial stiffness associated with the age-dependent effects on pulmonary pressures. Conclusion: These data demonstrate that in echocardiographically normal adults, pulmonary artery systolic pressure increases with advancing age. This increase is seen at rest and with exercise. These increases in pulmonary pressure occur in association with decreasing transpulmonary flow and increases in systemic pulse pressure, suggesting that age-associated blood vessel stiffening may contribute to these differences in pulmonary artery systolic pressure.

  19. [Baroreflexes originated in vertebral artery zones upon peripheral vein tonus, systemic arterial blood pressure, and external respiration].

    Science.gov (United States)

    Agadzhanian, N A; Kupriianov, S V

    2008-06-01

    The investigation was intended to study the role ofbaroreceptors ofhemodynamically isolated zone of vertebral arteries in regulation of peripheral veins tonus, arterial pressure and external respiration. Pressure decrease in this vascular reflexogenic zone led to reflex responses of increase in femoral vein tonus, elevation of blood pressure level and stimulation of external respiration. The opposite reflex responses of cardio-respiratory functional system to initial pressure activation of vertebral arteries baroreceptors are observed. Basing on generalization of our own findings and similar physiological and morphological researches of other authors, it is established that afferentation from the vertebral artery zone is a reflexogenic factor of somatic muscles' veins tonus regulation. These reflexes of capacity vessels tonic activity changes are part of cardio-respiratory responses of maintaining the tissue gaseous exchange.

  20. Factors associated with blood oxygen partial pressure and carbon dioxide partial pressure regulation during respiratory extracorporeal membrane oxygenation support: data from a swine model.

    Science.gov (United States)

    Park, Marcelo; Mendes, Pedro Vitale; Costa, Eduardo Leite Vieira; Barbosa, Edzangela Vasconcelos Santos; Hirota, Adriana Sayuri; Azevedo, Luciano Cesar Pontes

    2016-01-01

    The aim of this study was to explore the factors associated with blood oxygen partial pressure and carbon dioxide partial pressure. The factors associated with oxygen - and carbon dioxide regulation were investigated in an apneic pig model under veno-venous extracorporeal membrane oxygenation support. A predefined sequence of blood and sweep flows was tested. Oxygenation was mainly associated with extracorporeal membrane oxygenation blood flow (beta coefficient = 0.036mmHg/mL/min), cardiac output (beta coefficient = -11.970mmHg/L/min) and pulmonary shunting (beta coefficient = -0.232mmHg/%). Furthermore, the initial oxygen partial pressure and carbon dioxide partial pressure measurements were also associated with oxygenation, with beta coefficients of 0.160 and 0.442mmHg/mmHg, respectively. Carbon dioxide partial pressure was associated with cardiac output (beta coefficient = 3.578mmHg/L/min), sweep gas flow (beta coefficient = -2.635mmHg/L/min), temperature (beta coefficient = 4.514mmHg/ºC), initial pH (beta coefficient = -66.065mmHg/0.01 unit) and hemoglobin (beta coefficient = 6.635mmHg/g/dL). In conclusion, elevations in blood and sweep gas flows in an apneic veno-venous extracorporeal membrane oxygenation model resulted in an increase in oxygen partial pressure and a reduction in carbon dioxide partial pressure 2, respectively. Furthermore, without the possibility of causal inference, oxygen partial pressure was negatively associated with pulmonary shunting and cardiac output, and carbon dioxide partial pressure was positively associated with cardiac output, core temperature and initial hemoglobin.

  1. Partial Portal Vein Arterialization Attenuates Acute Bile Duct Injury Induced by Hepatic Dearterialization in a Rat Model.

    Science.gov (United States)

    Jiang, Jun; Wei, Jishu; Wu, Junli; Gao, Wentao; Li, Qiang; Jiang, Kuirong; Miao, Yi

    2016-01-01

    Hepatic infarcts or abscesses occur after hepatic artery interruption. We explored the mechanisms of hepatic deprivation-induced acute liver injury and determine whether partial portal vein arterialization attenuated this injury in rats. Male Sprague-Dawley rats underwent either complete hepatic arterial deprivation or partial portal vein arterialization, or both. Hepatic ischemia was evaluated using biochemical analysis, light microscopy, and transmission electron microscopy. Hepatic ATP levels, the expression of hypoxia- and inflammation-associated genes and proteins, and the expression of bile transporter genes were assessed. Complete dearterialization of the liver induced acute liver injury, as evidenced by the histological changes, significantly increased serum biochemical markers, decreased ATP content, increased expression of hypoxia- and inflammation-associated genes and proteins, and decreased expression of bile transporter genes. These detrimental changes were extenuated but not fully reversed by partial portal vein arterialization, which also attenuated ductular reaction and fibrosis in completely dearterialized rat livers. Collectively, complete hepatic deprivation causes severe liver injury, including bile infarcts and biloma formation. Partial portal vein arterialization seems to protect against acute ischemia-hypoxia-induced liver injury.

  2. Partial Portal Vein Arterialization Attenuates Acute Bile Duct Injury Induced by Hepatic Dearterialization in a Rat Model

    Directory of Open Access Journals (Sweden)

    Jun Jiang

    2016-01-01

    Full Text Available Hepatic infarcts or abscesses occur after hepatic artery interruption. We explored the mechanisms of hepatic deprivation-induced acute liver injury and determine whether partial portal vein arterialization attenuated this injury in rats. Male Sprague-Dawley rats underwent either complete hepatic arterial deprivation or partial portal vein arterialization, or both. Hepatic ischemia was evaluated using biochemical analysis, light microscopy, and transmission electron microscopy. Hepatic ATP levels, the expression of hypoxia- and inflammation-associated genes and proteins, and the expression of bile transporter genes were assessed. Complete dearterialization of the liver induced acute liver injury, as evidenced by the histological changes, significantly increased serum biochemical markers, decreased ATP content, increased expression of hypoxia- and inflammation-associated genes and proteins, and decreased expression of bile transporter genes. These detrimental changes were extenuated but not fully reversed by partial portal vein arterialization, which also attenuated ductular reaction and fibrosis in completely dearterialized rat livers. Collectively, complete hepatic deprivation causes severe liver injury, including bile infarcts and biloma formation. Partial portal vein arterialization seems to protect against acute ischemia-hypoxia-induced liver injury.

  3. Femoral artery pressure measurement to predict the outcome of arterial surgery in patients with multilevel disease

    DEFF Research Database (Denmark)

    Faris, I; Tønnesen, K H; Agerskov, K

    1982-01-01

    Direct measurement of the femoral artery pressure before operation has been used to predict the postoperative change in ankle and toe pressure in 102 limbs (83 patients) that underwent aortoiliac surgery for the treatment of atherosclerotic occlusion or stenosis affecting both the aortoiliac...... and femoral artery segments. Rest pain or gangrene was present in 74 limbs. In 26 other limbs simultaneous aortoiliac and femoral artery reconstructions were performed. The changes in both toe and ankle pressures could be confidently predicted from the preoperative data. A predicted toe pressure of lower than...... 25 mm Hg was associated with a high probability that amputation would be required. The chances of an amputation were less than 3% if a toe pressure higher than 40 mm Hg was predicted. If the predicted ankle pressure index was lower than 0.56, there was a 90% chance that intermittent claudication...

  4. Effects of partial portal vein arterialization on the hilar bile duct in a rat model.

    Science.gov (United States)

    Guo, Shao-Hua; Li, Chong-Hui; Chen, Yong-Liang; Song, Jian-Ning; Zhang, Ai-Qun; Zhou, Cheng

    2011-10-01

    Liver revascularization is frequently required during the enlarged radical operation for hilar cholangiocarcinoma involving the hepatic artery. Researchers have carried out a number of experiments applying partial portal vein arterialization (PVA) in clinical practice. In this study we aimed to establish a theoretical basis for clinical application of partial PVA and to investigate the effects of partial PVA on rat hilar bile duct and hepatic functions. Thirty rats were randomly and equally assigned into 3 groups: control (group A), hepatic artery ligation+bile duct recanalization (group B), and partial PVA+bile duct recanalization (group C). Proliferation and apoptosis of rat hilar bile duct epithelial cells, arteriolar counts of the peribiliary plexus (PBP) of the bile duct wall, changes in serum biochemistry, and pathologic changes in the bile duct were assessed 1 month after operation. The proliferation of hilar bile duct epithelial cells in group B was greater than in groups A and C (Philar bile duct epithelial cells were detected in any of the groups. The PBP arteriolar counts of the hilar bile duct wall were similar in groups A and C (P>0.05), but the count was lower in group B than in group A (Philar bile duct walls were observed only in group B. Partial PVA can restore the arterial blood supply of the hilar bile duct and significantly extenuate the injury to hilar bile duct epithelial cells resulting from hepatic artery ligation.

  5. Mathematical Modelling of Intraretinal Oxygen Partial Pressure

    African Journals Online (AJOL)

    Erah

    The system of non-linear differential equations was solved numerically using Runge-kutta. Nystroms method. ... artery occlusion. Keywords: Mathematical modeling, Intraretinal oxygen pressure, Retinal capillaries, Oxygen ..... Mass transfer,.

  6. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  7. Relationship of daily arterial blood pressure monitoring readings and arterial stiffness profile in male patients with chronic obstructive pulmonary disease combined with arterial hypertension

    Directory of Open Access Journals (Sweden)

    Karoli N.A.

    2013-06-01

    Full Text Available The aim of the study was to determine correlation between arterial blood pressure daily rhythm and daily profile of arterial stiffness in male patients with chronic obstructive pulmonary disease (COPD and arterial hypertension. Materials et methods: Prospective investigation comprised 45 male patients with COPD and arterial hypertension. Individuals of 40 years younger and 80 years elder, patients with diabetes, stroke, angina pectoris, or heart infarction, vascular diseases, and exacerbation of chronic disease, bronchial and pulmonary diseases of other etiology were excluded from the analyses. Comparison group included 47 patients with essential arterial hypertension and without chronic respiratory diseases closely similar on general parameters with patients from main clinical series. Twenty-four-hour arterial blood pressure monitoring (ABPM and daily arterial stiffness monitoring were performed using BPLab® MnSDP-2 apparatus (Petr Telegin, Russian Federation. Results: Patients with COPD combined with arterial hypertension with raised arterial stiffness measures prevail over individuals in essential hypertension group. There is pathological alteration of the ABPM circadian rhythm and raised «Pressure load» values in raised arterial stiffness group. Conclusion: We found ABPM raised parameters in patients with COPD and arterial hypertension. It confirms necessity of ABPM in daily arterial stiffness assessment in patients with COPD.

  8. Arterial Pressure Gradients during Upright Posture and 30 deg Head Down Tilt

    Science.gov (United States)

    Sanchez, E. R; William, J. M.; Ueno, T.; Ballard, R. E.; Hargens, A. R.; Holton, Emily M. (Technical Monitor)

    1997-01-01

    Gravity alters local blood pressure within the body so that arterial pressures in the head and foot are lower and higher, respectively, than that at heart level. Furthermore, vascular responses to local alterations of arterial pressure are probably important to maintain orthostatic tolerance upon return to the Earth after space flight. However, it has been difficult to evaluate the body's arterial pressure gradient due to the lack of noninvasive technology. This study was therefore designed to investigate whether finger arterial pressure (FAP), measured noninvasively, follows a normal hydrostatic pressure gradient above and below heart level during upright posture and 30 deg head down tilt (HDT). Seven healthy subjects gave informed consent and were 19 to 52 years old with a height range of 158 to 181 cm. A Finapres device measured arterial pressure at different levels of the body by moving the hand from 36 cm below heart level (BH) to 72 cm above heart level (AH) in upright posture and from 36 cm BH to 48 cm AH during HDT in increments of 12 cm. Mean FAP creased by 85 mmHg transitioning from BH to AH in upright posture, and the pressure gradient calculated from hydrostatic pressure difference (rho(gh)) was 84 mmHg. In HDT, mean FAP decreased by 65 mmHg from BH to AH, and the calculated pressure gradient was also 65 mmHg. There was no significant difference between the measured FAP gradient and the calculated pressure gradient, although a significant (p = 0.023) offset was seen for absolute arterial pressure in upright posture. These results indicate that arterial pressure at various levels can be obtained from the blood pressure at heart level by calculating rho(gh) + an offset. The offset equals the difference between heart level and the site of measurement. In summary, we conclude that local blood pressure gradients can be measured by noninvasive studies of FAP.

  9. A computational analysis of the long-term regulation of arterial pressure.

    Science.gov (United States)

    Beard, Daniel A; Pettersen, Klas H; Carlson, Brian E; Omholt, Stig W; Bugenhagen, Scott M

    2013-01-01

    The asserted dominant role of the kidneys in the chronic regulation of blood pressure and in the etiology of hypertension has been debated since the 1970s. At the center of the theory is the observation that the acute relationships between arterial pressure and urine production-the acute pressure-diuresis and pressure-natriuresis curves-physiologically adapt to perturbations in pressure and/or changes in the rate of salt and volume intake. These adaptations, modulated by various interacting neurohumoral mechanisms, result in chronic relationships between water and salt excretion and pressure that are much steeper than the acute relationships. While the view that renal function is the dominant controller of arterial pressure has been supported by computer models of the cardiovascular system known as the "Guyton-Coleman model", no unambiguous description of a computer model capturing chronic adaptation of acute renal function in blood pressure control has been presented. Here, such a model is developed with the goals of: 1. representing the relevant mechanisms in an identifiable mathematical model; 2. identifying model parameters using appropriate data; 3. validating model predictions in comparison to data; and 4. probing hypotheses regarding the long-term control of arterial pressure and the etiology of primary hypertension. The developed model reveals: long-term control of arterial blood pressure is primarily through the baroreflex arc and the renin-angiotensin system; and arterial stiffening provides a sufficient explanation for the etiology of primary hypertension associated with ageing. Furthermore, the model provides the first consistent explanation of the physiological response to chronic stimulation of the baroreflex.

  10. Management of Renal Artery Stenosis - an Update | Alhadad ...

    African Journals Online (AJOL)

    The role of the renal vasculature in eliciting renovascular hypertension (RVH) was established in 1934, when Goldblatt et al. [1] in a classical experimental study demonstrated that partial obstruction of the renal artery increased mean arterial blood pressure (BP). The pathophysiology of renal artery stenosis (RAS) is ...

  11. Pressure Myography to Study the Function and Structure of isolated small arteries

    DEFF Research Database (Denmark)

    Schjørring, Olav; Carlsson, Rune; Simonsen, Ulf

    2015-01-01

    Small arteries play an important role in regulation of peripheral resistance and organ perfusion. Here we describe a series of the methods allowing measurements in pressurized segments of small arteries from the systemic and coronary circulation of mice as well as other species. The pressure...... myography techniques described include measurements of wall structure, wall stress, strain, and of myogenic tone. The pressurized perfused small arteries also allow evaluation of responses to increases in pressure, flow, and drugs, where the main readout is changes in vascular diameter....

  12. Development of optoelectronic monitoring system for ear arterial pressure waveforms

    Science.gov (United States)

    Sasayama, Satoshi; Imachi, Yu; Yagi, Tamotsu; Imachi, Kou; Ono, Toshirou; Man-i, Masando

    1994-02-01

    Invasive intra-arterial blood pressure measurement is the most accurate method but not practical if the subject is in motion. The apparatus developed by Wesseling et al., based on a volume-clamp method of Penaz (Finapres), is able to monitor continuous finger arterial pressure waveforms noninvasively. The limitation of Finapres is the difficulty in measuring the pressure of a subject during work that involves finger or arm action. Because the Finapres detector is attached to subject's finger, the measurements are affected by inertia of blood and hydrostatic effect cause by arm or finger motion. To overcome this problem, the authors made a detector that is attached to subject's ear and developed and optoelectronic monitoring systems for ear arterial pressure waveform (Earpres). An IR LEDs, photodiode, and air cuff comprised the detector. The detector was attached to a subject's ear, and the space adjusted between the air cuff and the rubber plate on which the LED and photodiode were positioned. To evaluate the accuracy of Earpres, the following tests were conducted with participation of 10 healthy male volunteers. The subjects rested for about five minutes, then performed standing and squatting exercises to provide wide ranges of systolic and diastolic arterial pressure. Intra- and inter-individual standard errors were calculated according to the method of van Egmond et al. As a result, average, the averages of intra-individual standard errors for earpres appeared small (3.7 and 2.7 mmHg for systolic and diastolic pressure respectively). The inter-individual standard errors for Earpres were about the same was Finapres for both systolic and diastolic pressure. The results showed the ear monitor was reliable in measuring arterial blood pressure waveforms and might be applicable to various fields such as sports medicine and ergonomics.

  13. Aortic-Brachial Pulse Wave Velocity Ratio: A Measure of Arterial Stiffness Gradient Not Affected by Mean Arterial Pressure.

    Science.gov (United States)

    Fortier, Catherine; Desjardins, Marie-Pier; Agharazii, Mohsen

    2018-03-01

    Aortic stiffness, measured by carotid-femoral pulse wave velocity (cf-PWV), is used for the prediction of cardiovascular risk. This mini-review describes the nonlinear relationship between cf-PWV and operational blood pressure, presents the proposed methods to adjust for this relationship, and discusses a potential place for aortic-brachial PWV ratio (a measure of arterial stiffness gradient) as a blood pressure-independent measure of vascular aging. PWV is inherently dependent on the operational blood pressure. In cross-sectional studies, PWV adjustment for mean arterial pressure (MAP) is preferred, but still remains a nonoptimal approach, as the relationship between PWV and blood pressure is nonlinear and varies considerably among individuals due to heterogeneity in genetic background, vascular tone, and vascular remodeling. Extrapolations from the blood pressure-independent stiffness parameter β (β 0 ) have led to the creation of stiffness index β, which can be used for local stiffness. A similar approach has been used for cardio-ankle PWV to generate a blood pressure-independent cardio-ankle vascular index (CAVI). It was recently demonstrated that stiffness index β and CAVI remain slightly blood pressure-dependent, and a more appropriate formula has been proposed to make the proper adjustments. On the other hand, the negative impact of aortic stiffness on clinical outcomes is thought to be mediated through attenuation or reversal of the arterial stiffness gradient, which can also be influenced by a reduction in peripheral medium-sized muscular arteries in conditions that predispose to accelerate vascular aging. Arterial stiffness gradient, assessed by aortic-brachial PWV ratio, is emerging to be at least as good as cf-PWV for risk prediction, but has the advantage of not being affected by operating MAP. The negative impacts of aortic stiffness on clinical outcomes are proposed to be mediated through attenuation or reversal of arterial stiffness gradient

  14. Preoperative estimation of run off in patients with multiple level arterial obstructions as a guide to partial reconstructive surgery

    DEFF Research Database (Denmark)

    Noer, Ivan; Tønnesen, K H; Sager, P

    1978-01-01

    Preoperative measurements of direct femoral artery systolic pressure, indirect ankle systolic pressure and direct brachial artery systolic pressure were carried out in nine patients with severe ischemia and arterial occlusions both proximal and distal to the ingvinal ligament. The pressure......-rise at the ankle was estimated preoperatively by assuming that the ankle pressure would rise in proportion to the rise in femoral artery pressure. Thus it was predicted that reconstruction of the iliac obstruction with aorta-femoral pressure gradients from 44 to 96 mm Hg would result in a rise in ankle pressure...... of 16--54 mm Hg. The actual rise in ankle pressure one month after reconstruction of the iliac arteries ranged from 10 to 46 mm Hg and was well correlated to the preoperative estimations. In conclusion, by proper pressure measurements the run-off problem of multiple level arterial occlusions can...

  15. Predicting Electrocardiogram and Arterial Blood Pressure Waveforms with Different Echo State Network Architectures

    Science.gov (United States)

    2014-11-01

    Predicting Electrocardiogram and Arterial Blood Pressure Waveforms with Different Echo State Network Architectures Allan Fong, MS1,3, Ranjeev...the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the...type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network

  16. Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

    International Nuclear Information System (INIS)

    Gupta, Nakul; Patel, Anish; Ensor, Joe; Ahrar, Kamran; Ahrar, Judy; Tam, Alda; Odisio, Bruno; Huang, Stephen; Murthy, Ravi; Mahvash, Armeen; Avritscher, Rony; McRae, Stephen; Sabir, Sharjeel; Wallace, Michael; Matin, Surena; Gupta, Sanjay

    2017-01-01

    PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

  17. Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Nakul [Houston Methodist Hospital (United States); Patel, Anish [The University of Texas Southwestern Medical Center (United States); Ensor, Joe [Houston Methodist Research Institute, The Houston Methodist Cancer Center (United States); Ahrar, Kamran; Ahrar, Judy; Tam, Alda; Odisio, Bruno; Huang, Stephen; Murthy, Ravi; Mahvash, Armeen; Avritscher, Rony; McRae, Stephen; Sabir, Sharjeel; Wallace, Michael [The University of Texas MD Anderson Cancer Center, Department of Interventional Radiology (United States); Matin, Surena [The University of Texas MD Anderson Cancer Center, Department of Urology (United States); Gupta, Sanjay, E-mail: sgupta@mdanderson.org [The University of Texas MD Anderson Cancer Center, Department of Interventional Radiology (United States)

    2017-02-15

    PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

  18. Carotid artery disease and low cerebral perfusion pressure

    DEFF Research Database (Denmark)

    Schroeder, T; Utzon, N P; Aabech, J

    1990-01-01

    Direct internal carotid artery blood pressure measurements in patients undergoing carotid endarterectomy identified 49 patients, among 239 consecutive cases (21%), who had a reduction in perfusion pressure of 20% or more. The clinical history, objective findings and angiographic data were compared...

  19. Effect of oxygen partial pressure on production of animal virus (VSV)

    OpenAIRE

    Lim, Hyun S.; Chang, Kern H.; Kim, Jung H.

    1999-01-01

    The effect of oxygen partial pressure on viral replication was investigated with Vero/VSV system. At 10% oxygen partial pressure in spinner culture, VSV titer was significantly increased 130 fold compared to that obtained at 21%. A similar result was obtained for viral production in 1liter bioreactor. This implies that oxygen partial pressure during viral production has to be low. In low oxygen partial pressure, malondialdehyde concentration was decreased about 5 fold. Thus, low oxygen partia...

  20. Intraoperative indocyanine green fluorescent angiography-assisted modified superior gluteal artery perforator flap for reconstruction of sacral pressure sores.

    Science.gov (United States)

    Chang, Chun-Kai; Wu, Chien-Ju; Chen, Chun-Yu; Wang, Chi-Yu; Chu, Tzi-Shiang; Hsu, Kuo-Feng; Chiu, Han-Ting; Liu, Hung-Hui; Chou, Chang-Yi; Wang, Chih-Hsin; Lin, Chin-Ta; Dai, Niann-Tzyy; Tzeng, Yuan-Sheng

    2017-12-01

    Pressure sores are often observed in patients who are bedridden. They can be a severe problem not only for patients and their caregivers but also for plastic surgeons. Here, we describe a new method of superior gluteal artery perforator flap harvesting and anchoring with the assistance of intraoperative indocyanine green fluorescent angiography. In this report, we describe the procedure and outcomes for 19 patients with grades III and IV sacral pressure sores who underwent the operation between September 2015 and November 2016. All flaps survived, and two experienced wound-edge partial dehiscence. With the assistance of this imaging device, we were able to acquire a reliable superior gluteal artery perforator flap and perform modified operations with it that are safe, easy to learn and associated with fewer complications than are traditional. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. Implantable blood pressure sensor for analyzing elasticity in arteries

    Science.gov (United States)

    Franco-Ayala, Marco; Martínez-Piñón, Fernando; Reyes-Barranca, Alfredo; Sánchez de la Peña, Salvador; Álvarez-Chavez, José A.

    2009-03-01

    MEMS technology could be an option for the development of a pressure sensor which allows the monitoring of several electronic signals in humans. In this work, a comparison is made between the typical elasticity curves of several arteries in the human body and the elasticity obtained for MEMS silicon microstructures such as membranes and cantilevers employing Finite Element analysis tools. The purpose is to identify which types of microstructures are mechanically compatible with human arteries. The goal is to integrate a blood pressure sensor which can be implanted in proximity with an artery. The expected benefits for this type of sensor are mainly to reduce the problems associated with the use of bulk devices through the day and during several days. Such a sensor could give precise blood pressure readings in a continuous or periodic form, i.e. information that is especially important for some critical cases of hypertension patients.

  2. Peritumoral Artery Scoring System: a Novel Scoring System to Predict Renal Function Outcome after Laparoscopic Partial Nephrectomy.

    Science.gov (United States)

    Zhang, Ruiyun; Wu, Guangyu; Huang, Jiwei; Shi, Oumin; Kong, Wen; Chen, Yonghui; Xu, Jianrong; Xue, Wei; Zhang, Jin; Huang, Yiran

    2017-06-06

    The present study aimed to assess the impact of peritumoral artery characteristics on renal function outcome prediction using a novel Peritumoral Artery Scoring System based on computed tomography arteriography. Peritumoral artery characteristics and renal function were evaluated in 220 patients who underwent laparoscopic partial nephrectomy and then validate in 51 patients with split and total glomerular filtration rate (GFR). In particular, peritumoral artery classification and diameter were measured to assign arteries into low, moderate, and high Peritumoral Artery Scoring System risk categories. Univariable and multivariable logistic regression analyses were then used to determine risk factors for major renal functional decline. The Peritumoral Artery Scoring System and four other nephrometry systems were compared using receiver operating characteristic curve analysis. The Peritumoral Artery Scoring System was significantly superior to the other systems for predicting postoperative renal function decline (p system was a superior independent predictor of estimated glomerular filtration rate (eGFR) decline (area-under-the-curve = 0.865, p renal function outcome after laparoscopic partial nephrectomy.

  3. Changes in Cerebral Partial Oxygen Pressure and Cerebrovascular Reactivity During Intracranial Pressure Plateau Waves.

    Science.gov (United States)

    Lang, Erhard W; Kasprowicz, Magdalena; Smielewski, Peter; Pickard, John; Czosnyka, Marek

    2015-08-01

    Plateau waves in intracranial pressure (ICP) are frequently recorded in neuro intensive care and are not yet fully understood. To further investigate this phenomenon, we analyzed partial pressure of cerebral oxygen (pbtO2) and a moving correlation coefficient between ICP and mean arterial blood pressure (ABP), called PRx, along with the cerebral oxygen reactivity index (ORx), which is a moving correlation coefficient between cerebral perfusion pressure (CPP) and pbtO2 in an observational study. We analyzed 55 plateau waves in 20 patients after severe traumatic brain injury. We calculated ABP, ABP pulse amplitude (ampABP), ICP, CPP, pbtO2, heart rate (HR), ICP pulse amplitude (ampICP), PRx, and ORx, before, during, and after each plateau wave. The analysis of variance with Bonferroni post hoc test was used to compare the differences in the variables before, during, and after the plateau wave. We considered all plateau waves, even in the same patient, independent because they are separated by long intervals. We found increases for ICP and ampICP according to our operational definitions for plateau waves. PRx increased significantly (p = 0.00026), CPP (p pressure remains stable in ICP plateau waves, while cerebral autoregulatory indices show distinct changes, which indicate cerebrovascular reactivity impairment at the top of the wave. PbtO2 decreases during the waves and may show a slight overshoot after normalization. We assume that this might be due to different latencies of the cerebral blood flow and oxygen level control mechanisms. Other factors may include baseline conditions, such as pre-plateau wave cerebrovascular reactivity or pbtO2 levels, which differ between studies.

  4. Marginal artery stump pressure in left colic artery-preserving rectal cancer surgery: a clinical trial.

    Science.gov (United States)

    Guo, Yuchen; Wang, Daguang; He, Liang; Zhang, Yang; Zhao, Shishun; Zhang, Luyao; Sun, Xuan; Suo, Jian

    2017-07-01

    The aim of this clinical trial is to evaluate the influence of high and low ligation of the inferior mesenteric artery with apical lymph node dissection on the anastomotic blood supply, lymph node retrieval rate, operative time and anastomotic leakage rate in rectal cancer surgery. A total of 57 Chinese patients were randomly distributed into group A and group B and underwent radical resection of rectal cancer. Patients in group A underwent high ligation of the inferior mesenteric artery, and patients in group B underwent apical lymph node resection around the root of the inferior mesenteric artery with preservation of the left colic artery. The marginal artery stump pressure was measured after colon and artery reconstruction. Systemic pressure, distal colon length, operative time and lymph node retrieval rate were measured and recorded. The results were analysed and related to patient characteristics and post-operative complications. The anastomotic blood supply negatively and linearly correlated with age and distal colon length and showed a positive linear correlation with systemic pressure. Patients who received low ligation with apical lymph node dissection had a better anastomotic blood supply than those who received high ligation. No differences were found in lymph node retrieval rate, operative time and anastomotic leakage rate. Anastomotic leakage was associated with a worse anastomotic blood supply. Low ligation with apical lymph node dissection in rectal cancer treatment provides better anastomotic blood supply but is not associated with differences in node retrieval rate or operation time. © 2015 Royal Australasian College of Surgeons.

  5. Changes in oxygen partial pressure of brain tissue in an animal model of obstructive apnea

    Directory of Open Access Journals (Sweden)

    Torres Marta

    2010-01-01

    Full Text Available Abstract Background Cognitive impairment is one of the main consequences of obstructive sleep apnea (OSA and is usually attributed in part to the oxidative stress caused by intermittent hypoxia in cerebral tissues. The presence of oxygen-reactive species in the brain tissue should be produced by the deoxygenation-reoxygenation cycles which occur at tissue level during recurrent apneic events. However, how changes in arterial blood oxygen saturation (SpO2 during repetitive apneas translate into oxygen partial pressure (PtO2 in brain tissue has not been studied. The objective of this study was to assess whether brain tissue is partially protected from intermittently occurring interruption of O2 supply during recurrent swings in arterial SpO2 in an animal model of OSA. Methods Twenty-four male Sprague-Dawley rats (300-350 g were used. Sixteen rats were anesthetized and non-invasively subjected to recurrent obstructive apneas: 60 apneas/h, 15 s each, for 1 h. A control group of 8 rats was instrumented but not subjected to obstructive apneas. PtO2 in the cerebral cortex was measured using a fast-response oxygen microelectrode. SpO2 was measured by pulse oximetry. The time dependence of arterial SpO2 and brain tissue PtO2 was carried out by Friedman repeated measures ANOVA. Results Arterial SpO2 showed a stable periodic pattern (no significant changes in maximum [95.5 ± 0.5%; m ± SE] and minimum values [83.9 ± 1.3%]. By contrast, brain tissue PtO2 exhibited a different pattern from that of arterial SpO2. The minimum cerebral cortex PtO2 computed during the first apnea (29.6 ± 2.4 mmHg was significantly lower than baseline PtO2 (39.7 ± 2.9 mmHg; p = 0.011. In contrast to SpO2, the minimum and maximum values of PtO2 gradually increased (p 2 were significantly greater relative to baseline and the first apnea dip, respectively. Conclusions These data suggest that the cerebral cortex is partially protected from intermittently occurring interruption of

  6. Partial splenic artery embolization with gelatin sponge or with lipiodol for hypersplenism: a comparative study

    International Nuclear Information System (INIS)

    Liu Yamin; Sun Gangqing; Qin Hao; Wang Chongbao

    2010-01-01

    Objective: To discuss the effects and the complications of partial splenic artery embolization with gelatin sponge or with lipiodol for hypersplenism, to provide scientific information helpful for the selection of embolization materials in clinical practice. Methods: Partial splenic artery embolization with gelatin sponge was performed in forty patients with hypersplenism due to cirrhosis (gelatin sponge group) and partial splenic artery embolization with lipiodol was carried out in another thirty-nine patients (lipiodol group). The clinical data were retrospectively analyzed. The laboratory studies, complications and recurrence were observed and compared between two groups. Results: No significant difference in the reduction of splenic size, in the hemoglobin levels and in the thrombocyte and leucocyte counts existed between two groups (P > 0.05). However, the platelet count in lipiodol group was obviously decreased three months after the treatment. The occurrence of complications in gelatin sponge group was much higher than that in lipiodol group (P < 0.05). The toxic reaction of the liver and gastrointestinal tract in lipiodol group was significantly slighter than that in gelatin sponge group. Conclusion: Partial splenic artery embolization with lipiodol should be employed for the treatment of hypersplenism when the patient is elder and the disease is accompanied by poor liver function, massive ascites, severe dysfunction of blood coagulation and serious portal hypertension. (authors)

  7. Oxygen partial pressure sensor for gases

    International Nuclear Information System (INIS)

    Barbero, J.A.; Azcona, M.A.; Orce, A.

    1997-01-01

    Precise measurement of very low oxygen partial pressure is important in both laboratories and industries. Particularly in nuclear industry, it is relevant in the different steps of the nuclear fuel fabrication. It is presented an instrument which is handy and of easy construction, suitable for the measurement of oxygen partial pressure of gases, in the range of 10 -6 -1 atm. It is based on a solid electrolyte galvanic cell, using Yttria doped zirconia as a ceramic membrane. Through an indirect measurement and calibration, the instrument can be used to measure the content of free oxygen in liquids. It is a import feature in NPP instrumentation. The equipment was calibrated with mixtures of special nonreactive gases. (author). 5 refs

  8. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure

    NARCIS (Netherlands)

    L.V. Wain (Louise); G.C. Verwoert (Germaine); P.F. O'Reilly (Paul); G. Shi (Gang); T. Johnson (Toby); M. Bochud (Murielle); K. Rice (Kenneth); P. Henneman (Peter); A.V. Smith (Albert Vernon); G.B. Ehret (Georg); N. Amin (Najaf); M.G. Larson (Martin); V. Mooser (Vincent); D. Hadley (David); M. Dörr (Marcus); J.C. Bis (Joshua); T. Aspelund (Thor); T. Esko (Tõnu); A.C.J.W. Janssens (Cécile); J.H. Zhao (Jing Hua); S.C. Heath (Simon); M. Laan (Maris); J. Fu (Jingyuan); G. Pistis (Giorgio); J. Luan; G. Lucas (Gavin); N. Pirastu (Nicola); I. Pichler (Irene); A.U. Jackson (Anne); R.J. Webster (Rebecca J.); F.F. Zhang; J. Peden (John); R. Schmidt (Reinhold); T. Tanaka (Toshiko); H. Campbell (Harry); W. Igl (Wilmar); Y. Milaneschi (Yuri); J.J. Hottenga (Jouke Jan); V. Vitart (Veronique); D.I. Chasman (Daniel); S. Trompet (Stella); J.L. Bragg-Gresham (Jennifer L.); B.Z. Alizadeh (Behrooz); J.C. Chambers (John); X. Guo (Xiuqing); T. Lehtimäki (Terho); B. Kuhnel (Brigitte); L.M. Lopez; O. Polasek (Ozren); M. Boban (Mladen); C.P. Nelson (Christopher P.); A.C. Morrison (Alanna); V. Pihur (Vasyl); S.K. Ganesh (Santhi); A. Hofman (Albert); S. Kundu (Suman); F.U.S. Mattace Raso (Francesco); F. Rivadeneira Ramirez (Fernando); E.J.G. Sijbrands (Eric); A.G. Uitterlinden (André); S.J. Hwang; R.S. Vasan (Ramachandran Srini); Y.A. Wang (Ying); S.M. Bergmann (Sven); P. Vollenweider (Peter); G. Waeber (Gérard); J. Laitinen (Jaana); A. Pouta (Anneli); P. Zitting (Paavo); W.L. McArdle (Wendy); H.K. Kroemer (Heyo); U. Völker (Uwe); H. Völzke (Henry); N.L. Glazer (Nicole); K.D. Taylor (Kent); T.B. Harris (Tamara); H. Alavere (Helene); T. Haller (Toomas); A. Keis (Aime); M.L. Tammesoo; Y.S. Aulchenko (Yurii); K-T. Khaw (Kay-Tee); P. Galan (Pilar); S. Hercberg (Serge); G.M. Lathrop (Mark); S. Eyheramendy (Susana); E. Org (Elin); S. Sõber (Siim); X. Lu (Xiaowen); I.M. Nolte (Ilja); B.W.J.H. Penninx (Brenda); T. Corre (Tanguy); C. Masciullo (Corrado); C. Sala (Cinzia); L. Groop (Leif); B.F. Voight (Benjamin); O. Melander (Olle); C.J. O'Donnell (Christopher); V. Salomaa (Veikko); P. d' Adamo (Pio); A. Fabretto (Antonella); F. Faletra (Flavio); S. Ulivi (Shelia); F. Del Greco M (Fabiola); M.F. Facheris (Maurizio); F.S. Collins (Francis); R.N. Bergman (Richard); J.P. Beilby (John); J. Hung (Judy); A.W. Musk (Arthur); M. Mangino (Massimo); S.Y. Shin (So Youn); N. Soranzo (Nicole); H. Watkins (Hugh); A. Goel (Anuj); A. Hamsten (Anders); P. Gider (Pierre); M. Loitfelder (Marisa); M. Zeginigg (Marion); D.G. Hernandez (Dena); S.S. Najjar (Samer); P. Navarro (Pau); S.H. Wild (Sarah); A.M. Corsi (Anna Maria); A. Singleton (Andrew); E.J.C. de Geus (Eco); G.A.H.M. Willemsen (Gonneke); A.N. Parker (Alex); L.M. Rose (Lynda); B.M. Buckley (Brendan M.); D.J. Stott (David. J.); M. Orrù (Marco); M. Uda (Manuela); M.M. van der Klauw (Melanie); X. Li (Xiaohui); J. Scott (James); Y.D.I. Chen (Yii-Der Ida); G.L. Burke (Greg); M. Kähönen (Mika); J. Viikari (Jorma); A. Döring (Angela); T. Meitinger (Thomas); G.S. Davis; J.M. Starr (John); V. Emilsson (Valur); A.S. Plump (Andrew); J.H. Lindeman (Jan H.); P.A.C. 't Hoen (Peter); I.R. König (Inke); J.F. Felix (Janine); R. Clarke; J. Hopewell; H. Ongen (Halit); M.M.B. Breteler (Monique); S. Debette (Stéphanie); A.L. DeStefano (Anita); M. Fornage (Myriam); G.F. Mitchell (Gary); H. Holm (Hilma); K. Stefansson (Kari); G. Thorleifsson (Gudmar); U. Thorsteinsdottir (Unnur); N.J. Samani (Nilesh); M. Preuss (Michael); I. Rudan (Igor); C. Hayward (Caroline); I.J. Deary (Ian); H.E. Wichmann (Heinz Erich); O. Raitakari (Olli); W. Palmas (Walter); J.S. Kooner (Jaspal); R.P. Stolk (Ronald); J.W. Jukema (Jan Wouter); A.F. Wright (Alan); D.I. Boomsma (Dorret); S. Bandinelli (Stefania); U. Gyllensten (Ulf); J.F. Wilson (James); L. Ferrucci (Luigi); M. Farrall (Martin); T.D. Spector (Timothy); L.J. Palmer; J. Tuomilehto (Jaakko); A. Pfeufer (Arne); P. Gasparini (Paolo); D.S. Siscovick (David); D. Altshuler (David); R.J.F. Loos (Ruth); D. Toniolo (Daniela); H. Snieder (Harold); C. Gieger (Christian); P. Meneton (Pierre); N.J. Wareham (Nick); B.A. Oostra (Ben); A. Metspalu (Andres); L.J. Launer (Lenore); R. Rettig (Rainer); D.P. Strachan (David); J.S. Beckmann (Jacques); J.C.M. Witteman (Jacqueline); J.A.P. Willems van Dijk (Ko); E.A. Boerwinkle (Eric); M. Boehnke (Michael); P.M. Ridker (Paul); M.R. Järvelin; A. Chakravarti (Aravinda); J. Erdmann (Jeanette); V. Gudnason (Vilmundur); C. Newton-Cheh (Christopher); D. Levy (Daniel); P. Arora (Pankaj); P. Munroe (Patricia); B.M. Psaty (Bruce); M. Caulfield (Mark); D.C. Rao (Dabeeru C.); P. Elliott (Paul); P. Tikka-Kleemola (Päivi); G.R. Abecasis (Gonçalo); I.E. Barroso (Inês)

    2011-01-01

    textabstractNumerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans. We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N =

  9. A system for incubations at high gas partial pressure

    Directory of Open Access Journals (Sweden)

    Patrick eSauer

    2012-02-01

    Full Text Available High-pressure is a key feature of deep subsurface environments. High partial pressure of dissolved gasses plays an important role in microbial metabolism, because thermodynamic feasibility of many reactions depends on the concentration of reactants. For gases, this is controlled by their partial pressure, which can exceed one MPa at in-situ conditions. Therefore, high hydrostatic pressure alone is not sufficient to recreate true deep subsurface in-situ conditions, but the partial pressure of dissolved gasses has to be controlled as well.We developed an incubation system that allows for incubations at hydrostatic pressure up to 60 MPa, temperatures up to 120° C and at high gas partial pressure. The composition and partial pressure of gasses can be manipulated during the experiment. The system is mainly made from off-the-shelf components with only very few custom-made parts. A flexible and inert PVDF incubator sleeve, which is almost impermeable for gases, holds the sample and separates it from the pressure fluid. The flexibility of the incubator sleeve allows for sub-sampling of the medium without loss of pressure. Experiments can be run in both static and flow through mode. The incubation system described here is usable for versatile purposes, not only the incubation of microorganisms and determination of growth rates, but also for chemical degradation or extraction experiments under high gas saturation, e.g. fluid-gas-rock-interactions in relation to carbon dioxide sequestration.As an application of the system we extracted organic acids from sub-bituminous coal using H2O as well as a H2O-CO2 mixture at elevated temperature (90°C and pressure (5 MPa. Subsamples were taken during the incubation and analysed by ion chromatography. Furthermore we demonstrated the applicability of the system for studies of microbial activity, using samples from the Isis mud volcano. We could detect an increase in sulphate reduction rate upon the addition of

  10. Autologous Transfusion of Stored Red Blood Cells Increases Pulmonary Artery Pressure

    Science.gov (United States)

    Pinciroli, Riccardo; Stowell, Christopher P.; Wang, Lin; Yu, Binglan; Fernandez, Bernadette O.; Feelisch, Martin; Mietto, Cristina; Hod, Eldad A.; Chipman, Daniel; Scherrer-Crosbie, Marielle; Bloch, Kenneth D.; Zapol, Warren M.

    2014-01-01

    Rationale: Transfusion of erythrocytes stored for prolonged periods is associated with increased mortality. Erythrocytes undergo hemolysis during storage and after transfusion. Plasma hemoglobin scavenges endogenous nitric oxide leading to systemic and pulmonary vasoconstriction. Objectives: We hypothesized that transfusion of autologous blood stored for 40 days would increase the pulmonary artery pressure in volunteers with endothelial dysfunction (impaired endothelial production of nitric oxide). We also tested whether breathing nitric oxide before and during transfusion could prevent the increase of pulmonary artery pressure. Methods: Fourteen obese adults with endothelial dysfunction were enrolled in a randomized crossover study of transfusing autologous, leukoreduced blood stored for either 3 or 40 days. Volunteers were transfused with 3-day blood, 40-day blood, and 40-day blood while breathing 80 ppm nitric oxide. Measurements and Main Results: The age of volunteers was 41 ± 4 years (mean ± SEM), and their body mass index was 33.4 ± 1.3 kg/m2. Plasma hemoglobin concentrations increased after transfusion with 40-day and 40-day plus nitric oxide blood but not after transfusing 3-day blood. Mean pulmonary artery pressure, estimated by transthoracic echocardiography, increased after transfusing 40-day blood (18 ± 2 to 23 ± 2 mm Hg; P transfusing 3-day blood (17 ± 2 to 18 ± 2 mm Hg; P = 0.5). Breathing nitric oxide decreased pulmonary artery pressure in volunteers transfused with 40-day blood (17 ± 2 to 12 ± 1 mm Hg; P Transfusion of autologous leukoreduced blood stored for 40 days was associated with increased plasma hemoglobin levels and increased pulmonary artery pressure. Breathing nitric oxide prevents the increase of pulmonary artery pressure produced by transfusing stored blood. Clinical trial registered with www.clinicaltrials.gov (NCT 01529502). PMID:25162920

  11. A Novel Interpretation for Arterial Pulse Pressure Amplification in Health and Disease

    Directory of Open Access Journals (Sweden)

    Manuel R. Alfonso

    2018-01-01

    Full Text Available Arterial pressure waves have been described in one dimension using several approaches, such as lumped (Windkessel or distributed (using Navier-Stokes equations models. An alternative approach consists of modeling blood pressure waves using a Korteweg-de Vries (KdV equation and representing pressure waves as combinations of solitons. This model captures many key features of wave propagation in the systemic network and, in particular, pulse pressure amplification (PPA, which is a mechanical biomarker of cardiovascular risk. The main objective of this work is to compare the propagation dynamics described by a KdV equation in a human-like arterial tree using acquired pressure waves. Furthermore, we analyzed the ability of our model to reproduce induced elastic changes in PPA due to different pathological conditions. To this end, numerical simulations were performed using acquired central pressure signals from different subject groups (young, adults, and hypertensive as input and then comparing the output of the model with measured radial artery pressure waveforms. Pathological conditions were modeled as changes in arterial elasticity (E. Numerical results showed that the model was able to propagate acquired pressure waveforms and to reproduce PPA variations as a consequence of elastic changes. Calculated elasticity for each group was in accordance with the existing literature.

  12. Oxygen partial pressure sensor for gases

    Energy Technology Data Exchange (ETDEWEB)

    Barbero, J.A.; Azcona, M.A.; Orce, A. [Comision Nacional de Energia Atomica, San Carlos de Bariloche (Argentina). Centro Atomico Bariloche

    1997-10-01

    Precise measurement of very low oxygen partial pressure is important in both laboratories and industries. Particularly in nuclear industry, it is relevant in the different steps of the nuclear fuel fabrication. It is presented an instrument which is handy and of easy construction, suitable for the measurement of oxygen partial pressure of gases, in the range of 10{sup -6}-1 atm. It is based on a solid electrolyte galvanic cell, using Yttria doped zirconia as a ceramic membrane. Through an indirect measurement and calibration, the instrument can be used to measure the content of free oxygen in liquids. It is a import feature in NPP instrumentation. The equipment was calibrated with mixtures of special nonreactive gases. (author). 5 refs.

  13. Does intraoperative low arterial partial pressure of oxygen increase the risk of surgical site infection following emergency exploratory laparotomy in horses?

    Science.gov (United States)

    Costa-Farré, Cristina; Prades, Marta; Ribera, Thaïs; Valero, Oliver; Taurà, Pilar

    2014-04-01

    Decreased tissue oxygenation is a critical factor in the development of wound infection as neutrophil mediated oxidative killing is an essential mechanism against surgical pathogens. The objective of this prospective case series was to assess the impact of intraoperative arterial partial pressure of oxygen (PaO2) on surgical site infection (SSI) in horses undergoing emergency exploratory laparotomy for acute gastrointestinal disease. The anaesthetic and antibiotic protocol was standardised. Demographic data, surgical potential risk factors and PaO2, obtained 1h after induction of anaesthesia were recorded. Surgical wounds were assessed daily for infection during hospitalisation and follow up information was obtained after discharge. A total of 84 adult horses were included. SSI developed in 34 (40.4%) horses. Multivariate logistic regression showed that PaO2, anaesthetic time and subcutaneous suture material were predictors of SSI (AUC=0.76, sensitivity=71%, specificity=65%). The use of polyglycolic acid sutures increased the risk and horses with a PaO2 value 2h had the highest risk of developing SSI (OR=9.01; 95% CI 2.28-35.64). The results of this study confirm the hypothesis that low intraoperative PaO2 contributes to the development of SSI following colic surgery. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Quadratic function between arterial partial oxygen pressure and mortality risk in sepsis patients: an interaction with simplified acute physiology score.

    Science.gov (United States)

    Zhang, Zhongheng; Ji, Xuqing

    2016-10-13

    Oxygen therapy is widely used in emergency and critical care settings, while there is little evidence on its real therapeutic effect. The study aimed to explore the impact of arterial oxygen partial pressure (PaO 2 ) on clinical outcomes in patients with sepsis. A large clinical database was employed for the study. Subjects meeting the diagnostic criteria of sepsis were eligible for the study. All measurements of PaO 2 were extracted. The primary endpoint was death from any causes during hospital stay. Survey data analysis was performed by using individual ICU admission as the primary sampling unit. Quadratic function was assumed for PaO 2 and its interaction with other covariates were explored. A total of 199,125 PaO 2 samples were identified for 11,002 ICU admissions. Each ICU stay comprised 18 PaO 2 samples in average. The fitted multivariable model supported our hypothesis that the effect of PaO 2 on mortality risk was in quadratic form. There was significant interaction between PaO 2 and SAPS-I (p = 0.007). Furthermore, the main effect of PaO 2 on SOFA score was nonlinear. The study shows that the effect of PaO 2 on mortality risk is in quadratic function form, and there is significant interaction between PaO 2 and severity of illness.

  15. Variations in pulmonary artery occlusion pressure to estimate changes in pleural pressure.

    Science.gov (United States)

    Bellemare, Patrick; Goldberg, Peter; Magder, Sheldon A

    2007-11-01

    A readily available assessment of changes in pleural pressure would be useful for ventilator and fluid management in critically ill patients. We examined whether changes in pulmonary artery occlusion pressure (Ppao) adequately reflect respiratory changes in pleural pressure as assessed by changes in intraesophageal balloon pressure (Peso). We studied patients who had a pulmonary catheter and esophageal balloon surrounding a nasogastric tube as part of their care (n=24). We compared changes in Ppao (dPpao) to changes in Peso (dPeso) by Bland-Altman and regression analysis. Adequacy of balloon placement was assessed by performing Mueller maneuvers and adjusting the position to achieve a ratio of dPeso to change in tracheal pressure (dPtr) of 0.85 or higher. This was achieved in only 14 of the 24 subjects. We also compared dCVP to dPeso. The dPpao during spontaneous breaths and positive pressure breaths gave a good estimate of Peso but generally underestimated dPeso (bias=2.2 +8.2 and -3.9 cmH2O for the whole group). The dCVP was not as good a predictor (bias=2.9 +10.3 and -4.6). In patients who have a pulmonary artery catheter in place dPpao gives a lower estimate of changes in pleural pressure and may be more reliable than dPeso. The dCVP is a less reliable predictor than changes in pleural pressure.

  16. Analysis of Partial Volume Effects on Arterial Input Functions Using Gradient Echo: A Simulation Study

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Mikkelsen, Irene Klærke; Pedersen, Michael

    2009-01-01

    of an AIF voxel including the relaxation properties of blood and tissue. Artery orientations parallel and perpendicular to the main magnetic field were investigated and AIF voxels were modeled to either include or be situated close to a large artery. The impact of partial volume effects on quantitative...... perfusion metrics was investigated for the gradient echo pulse sequence at 1.5 T and 3.0 T. It is shown that the tissue contribution broadens and introduces fluctuations in the AIF. Furthermore, partial volume effects bias perfusion metrics in a nonlinear fashion, compromising quantitative perfusion...

  17. Agreement between arterial partial pressure of carbon dioxide and saturation of hemoglobin with oxygen values obtained by direct arterial blood measurements versus noninvasive methods in conscious healthy and ill foals.

    Science.gov (United States)

    Wong, David M; Alcott, Cody J; Wang, Chong; Bornkamp, Jennifer L; Young, Jessica L; Sponseller, Brett A

    2011-11-15

    To determine agreement between indirect measurements of end-tidal partial pressure of carbon dioxide (PetCO(2)) and saturation of hemoglobin with oxygen as measured by pulse oximetry (SpO(2)) with direct measurements of PaCO(2) and calculated saturation of hemoglobin with oxygen in arterial blood (SaO(2)) in conscious healthy and ill foals. Validation study. 10 healthy and 21 ill neonatal foals. Arterial blood gas analysis was performed on healthy and ill foals examined at a veterinary teaching hospital to determine direct measurements of PaCO(2) and PaO(2) along with SaO(2). Concurrently, PetCO(2) was measured with a capnograph inserted into a naris, and SpO(2) was measured with a reflectance probe placed at the base of the tail. Paired values were compared by use of Pearson correlation coefficients, and level of agreement was assessed with the Bland-Altman method. Mean ± SD difference between PaCO(2) and PetCO(2) was 0.1 ± 5.0 mm Hg. There was significant strong correlation (r = 0.779) and good agreement between PaCO(2) and PetCO(2). Mean ± SD difference between SaO(2) and SpO(2) was 2.5 ± 3.5%. There was significant moderate correlation (r = 0.499) and acceptable agreement between SaO(2) and SpO(2). Both PetCO(2) obtained by use of nasal capnography and SpO(2) obtained with a reflectance probe are clinically applicable and accurate indirect methods of estimating and monitoring PaCO(2) and SaO(2) in neonatal foals. Indirect methods should not replace periodic direct measurement of corresponding parameters.

  18. Determination of the partial pressure of thallium in high-pressure lamp arcs: A comparative study

    International Nuclear Information System (INIS)

    Karabourniotis, D.; Couris, S.; Damelincourt, J.J.; Aubes, M.

    1986-01-01

    The partial pressure of thallium in high-pressure Hg-TlI discharges with different mercury, thallium, and electron pressures has been measured by using the optically thin line Tl 655 nm and the self-reversed line Tl 535 nm. The partial pressure of the arc axis has been measured from the line Tl 655nm. The effective partial pressure has been measured from the self-reversed line Tl 535 nm on the basis of the multiparameter method, and it has been calculated from the known axis pressure of thallium and the calculation of its radial variation by taking into account the chemical reactions. The experimental results confirm the dispersion character of the blue wing of the line Tl 535 nm. The systematic difference obtained between the measured and calculated effective pressure, particularly at the moment of minimum electron density, may be interpreted by deviations from the local thermodynamic equilibrium (LTE) caused by overpopulation of the upper level of the line Tl 535 nm

  19. Fifteen years experience with finger arterial pressure monitoring : Assessment of the technology

    NARCIS (Netherlands)

    Imholz, B.P.M.; Wieling, W.; Montfrans, G.A. van; Wesseling, K.H.

    1998-01-01

    We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in

  20. Fifteen years experience with finger arterial pressure monitoring: assessment of the technology

    NARCIS (Netherlands)

    Imholz, B. P.; Wieling, W.; van Montfrans, G. A.; Wesseling, K. H.

    1998-01-01

    We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in

  1. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P blood pressure and HR from daytime...

  2. Arterial pressure during cardiopulmonary bypass is not associated with acute kidney injury

    DEFF Research Database (Denmark)

    Kandler, K; Jensen, M E; Nilsson, J C

    2015-01-01

    BACKGROUND: Acute kidney injury (AKI) after cardiac surgery is common and is associated with increased mortality. We wanted to investigate if the arterial pressure or the use of norepinephrine during cardiopulmonary bypass were associated with AKI. METHODS: A retrospective analysis of patients who...... underwent coronary artery bypass grafting with or without concomitant procedures was conducted. AKI was defined using the RIFLE criteria. Data on arterial pressure and use of norepinephrine during cardiopulmonary bypass were entered in a binary logistic regression model to control for possible perioperative...... and in higher amounts, during cardiopulmonary bypass, in patients who developed AKI. These differences in arterial pressures and use of norepinephrine between the groups were not found to be significant when entered in the binary logistic regression model. CONCLUSION: No independent relationship between...

  3. Straight versus tortuous retinal arteries in relation to blood pressure and genetics

    DEFF Research Database (Denmark)

    Taarnhøj, N C B B; Munch, I C; Sander, B

    2008-01-01

    dizygotic same-sex healthy twin pairs, aged 20 to 46 years, who were characterised by determination of retinal vessel diameters, arterial blood pressure, blood glucose, body mass index, smoking habits and retinal arterial tortuosity, using a three-level grading scale (straight, wavy, tortuous). Heritability......BACKGROUND/AIMS: To assess the relative influence of genetic and environmental factors on retinal arterial tortuosity and the association between tortuosity and various health indices in healthy young to middle-aged persons. METHODS: This cross-sectional study included 57 monozygotic and 52...... accounting for the remaining 18% (CI(95 )8, 36%). Increasing values of mean arterial blood pressure and body mass index were both associated with decreasing levels of retinal arterial tortuosity. CONCLUSION: There was a large variation in tortuosity of retinal arteries in these healthy subjects...

  4. Flurbiprofen axetil increases arterial oxygen partial pressure by decreasing intrapulmonary shunt in patients undergoing one-lung ventilation.

    Science.gov (United States)

    Chai, Xiao-Qing; Ma, Jun; Xie, Yan-Hu; Wang, Di; Chen, Kun-Zhou

    2015-12-01

    In the present study, we investigated whether flurbiprofen axetil (FA) alleviates hypoxemia during one-lung ventilation (OLV) by reducing the pulmonary shunt/total perfusion (Q s/Q t) ratio, and examined the relationship between the Q s/Q t ratio and the thromboxane B2 (TXB2)/6-keto-prostaglandin F1α (6-K-PGF1α) ratio. Sixty patients undergoing esophageal resection for carcinoma were randomly assigned to groups F and C (n = 30 for each group). FA and placebo were administered i.v. 15 min before skin incision in groups F and C, respectively. The partial pressure of arterial oxygen (PaO2) was measured and the Q s/Q t ratio was calculated. Serum TXB2, 6-K-PGF1α, and endothelin (ET) were measured by radioimmunoassay. The relationship between TXB2/6-K-PGF1α and Q s/Q t was investigated. Compared with group C, PaO2 was higher and the Q s/Q t ratio was lower during OLV in group F (P < 0.05). After treatment with FA, both serum TXB2 and 6-K-PGF1α decreased significantly (P < 0.05) but the TXB2/6-K-PGF1α ratio increased significantly (P < 0.01). Increases in the TXB2/6-K-PGF1α ratio were correlated with reductions in the Q s/Q t ratio during OLV in group F (r = -0.766, P < 0.01). There was no significant difference in serum ET between groups F and C. Treatment with FA reduced the Q s/Q t ratio and further increased the PaO2 level during OLV, possibly due to upregulation of the vasoactive agent TXB2/6-K-PGF1α ratio.

  5. Clinical significance of inter-arm pressure difference and ankle-brachial pressure index in patients with suspected coronary artery disease

    International Nuclear Information System (INIS)

    Igarashi, Yuko; Chikamori, Taishiro; Tomiyama, Hirofumi; Usui, Yasuhiro; Hida, Satoshi; Tanaka, Hirokazu; Nagao, Tadashi; Yamashina, Akira

    2007-01-01

    Although measuring blood pressure at the bilateral brachia is common in medical practice, its clinical significance in patients with suspected coronary artery disease (CAD) has not been fully clarified. The method of this study was to define the significance of inter-arm systolic blood pressure difference in patients with suspected CAD, and to assess the relationship between inter-arm pressure difference and CAD, simultaneous brachial and ankle blood pressure measurements and stress myocardial single-photon emission computed tomography (SPECT) were performed in 386 consecutive patients with suspected CAD, excluding those with previous myocardial infarction or coronary revascularization. Subclavian artery stenosis, defined as ≥15 mmHg inter-arm systolic blood pressure difference, was found in 27 patients (7%). Age (65±12 vs 65±11 years), male sex (21/27 vs 244/359), prevalence of hypertension (63% vs 56%), hypercholesterolemia (63% vs 62%), diabetes mellitus (33% vs 38%), cigarette smoking (44% vs 41%) and family history of CAD (15% vs 12%) were similar between patients with subclavian artery stenosis and those without. The incidence of decreased ankle-brachial pressure index (ABI) was higher (37% vs 12%, p=0.001), and percentage ischemic myocardium as assessed by SPECT was greater (9.0±8.5% vs 5.6±6.6%, p=0.05) in patients with subclavian artery stenosis than in those without. Furthermore, significant correlations were observed between inter-arm pressure difference and percentage ischemic myocardium (r=0.13; p=0.01), and ABI (r=-0.26, p<0.0001). Among 386 patients, 283 underwent coronary angiography, and 63% of those who had inter-arm blood pressure difference had CAD. Furthermore, 83% of those CAD patients had multi-vessel CAD, which is regarded as a high-risk subset for subsequent cardiac events. Inter-arm pressure difference is often found in patients with suspected CAD, and is associated with significant CAD and peripheral artery disease. Thus, inter

  6. The influence of participant characteristics on the relationship between cuff pressure and level of blood flow restriction.

    Science.gov (United States)

    Hunt, Julie E A; Stodart, Clare; Ferguson, Richard A

    2016-07-01

    Previous investigations to establish factors influencing the blood flow restriction (BFR) stimulus have determined cuff pressures required for complete arterial occlusion, which does not reflect the partial restriction prescribed for this training technique. This study aimed to establish characteristics that should be accounted for when prescribing cuff pressures required for partial BFR. Fifty participants were subjected to incremental blood flow restriction of the upper and lower limbs by proximal pneumatic cuff inflation. Popliteal and brachial artery diameter, blood velocity and blood flow was assessed with Doppler ultrasound. Height, body mass, limb circumference, muscle-bone cross-sectional area, adipose thickness (AT) and arterial blood pressure were measured and used in different models of hierarchical linear regression to predict the pressure at which 60 % BFR (partial occlusion) occurred. Combined analysis revealed a difference in cuff pressures required to elicit 60 % BFR in the popliteal (111 ± 12 mmHg) and brachial arteries (101 ± 12 mmHg). MAP (r = 0.58) and AT (r = -0.45) were the largest independent determinants of lower and upper body partial occlusion pressures. However, greater variance was explained by upper and lower limb regression models composed of DBP and BMI (48 %), and arm AT and DBP (30 %), respectively. Limb circumference has limited impact on the cuff pressure required for partial blood flow restriction which is in contrast to its recognised relationship with complete arterial occlusion. The majority of the variance in partial occlusion pressure remains unexplained by the predictor variables assessed in the present study.

  7. Increased serum urea to creatinine ratio and its negative correlation with arterial pressure in canine babesiosis.

    Science.gov (United States)

    Zygner, Wojciech; Gójska-Zygner, Olga

    2014-09-01

    The increase of the serum urea to creatinine ratio (UCR) was observed in dogs infected with Babesia canis. Previous studies have suggested that decrease of blood pressure can be one of the reasons for this phenomenon. In this work statistically significant increase of the UCR was observed in dogs with babesiosis. Comparison of the UCR between 23 azotaemic dogs and 25 non-azotaemic dogs infected with Babesia canis showed statistically significantly higher mean of the UCR in azotaemic dogs. Correlations between UCR and systolic, diastolic and mean arterial pressure (SAP, DAP and MAP) in 48 dogs infected with B. canis were negative (UCR and SAP: r = -0.3909; UCR and DAP: r = -0.3182; UCR and MAP: r = -0.3682) and statistically significant (p high, and there was no statistically significant correlation between UCR and arterial pressures in azotaemic dogs. Thus, it seems that decrease of blood pressure in dogs with babesiosis explains only partially the cause of increased UCR in infected dogs. The other authors suggested hyperureagenesis and myocardial injury as a potential reason for the increased UCR in canine babesiosis. Thus, further studies are needed to determine causes of increased UCR in dogs with babesiosis, especially on the connection between UCR changes and the concentrations of plasma cardiac troponins and ammonia, and the occurrence of occult blood on fecal examination.

  8. DEVICE FOR CONTROL OF OXYGEN PARTIAL PRESSURE

    Science.gov (United States)

    Bradner, H.; Gordon, H.S.

    1957-12-24

    A device is described that can sense changes in oxygen partial pressure and cause a corresponding mechanical displacement sufficient to actuate meters, valves and similar devices. A piston and cylinder arrangement contains a charge of crystalline metal chelate pellets which have the peculiar property of responding to variations in the oxygen content of the ambient atmosphere by undergoing a change in dimension. A lever system amplifies the relative displacement of the piston in the cylinder, and actuates the controlled valving device. This partial pressure oxygen sensing device is useful in controlled chemical reactions or in respiratory devices such as the oxygen demand meters for high altitude aircraft.

  9. Effects of hypoxia on the closing pressure of the canine systemic arterial circulation.

    Science.gov (United States)

    Sylvester, J T; Gilbert, R D; Traystman, R J; Permutt, S

    1981-10-01

    We studied the relationships among closing pressure (Pc) and indices of systemic arterial resistance (Ra) and compliance (Ca) during hypoxic hypoxia (HH) and carbon monoxide hypoxia (COH) in anesthetized dogs with cardiac bypass and constant ventilation. Closing pressure was measured as the lowest level to which arterial pressure (Pa) fell after inflow to the arterial bed was reduced suddenly to zero. Since the fall of Pa to Pc could be well-described as a single exponential function of time and since Pc was always greater than outflow (venous) pressure. Ra and CA were determined by applying a "vascular waterfall" model to the arterial bed. During HH, Pc increased while Ra and Ca decreased. During COH, Pc and Ra decreased, but Ca did not change. The Pc results indicate that during HH, but not COH, a large portion of the systemic arterial bed experienced a marked increase in vasomotor tone, a qualitative difference that would have been missed if Pc had not been measured. The relationship among Pc, Ra, and Ca during hypoxia suggest these indices may have been determined largely by different portions of the arterial bed in which tone changed independently.

  10. Pressure measurements in arterial feeders of brain arteriovenous malformations before and after endovascular embolization

    International Nuclear Information System (INIS)

    Henkes, H.; Gotwald, T.F.; Brew, S.; Kaemmerer, F.; Miloslavski, E.; Kuehne, D.

    2004-01-01

    Arteriovenous malformations (AVMs) are composed of abnormal arterial and venous vessels in the brain causing arteriovenous shunts of arterialized blood directly from pial arteries to draining veins. The hemodynamics of these lesions is not well-understood. Changes in blood flow and pressure are probably related to the natural history of AVMs and may also play a major role in AVM treatment. In this study intra-arterial pressure was measured in feeding arteries of AVMs using a microcatheter that had been placed for subsequent embolization treatment (201 measurements were performed in 95 patients before and after the embolization procedure). Results show a direct relationship between pressure changes and degree of embolization. Since pressure changes during the embolization procedure are relatively small, it seems unlikely that these changes are the direct cause of rupture and periprocedural bleedings. (orig.)

  11. 21 CFR 868.1200 - Indwelling blood oxygen partial pressure (PO2) analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indwelling blood oxygen partial pressure (PO2... Indwelling blood oxygen partial pressure (PO2) analyzer. (a) Identification. An indwelling blood oxygen... electrode) and that is used to measure, in vivo, the partial pressure of oxygen in blood to aid in...

  12. Respiratory sinus arrhythmia stabilizes mean arterial blood pressure at high-frequency interval in healthy humans.

    Science.gov (United States)

    Elstad, Maja; Walløe, Lars; Holme, Nathalie L A; Maes, Elke; Thoresen, Marianne

    2015-03-01

    Arterial blood pressure variations are an independent risk factor for end organ failure. Respiratory sinus arrhythmia (RSA) is a sign of a healthy cardiovascular system. However, whether RSA counteracts arterial blood pressure variations during the respiratory cycle remains controversial. We restricted normal RSA with non-invasive intermittent positive pressure ventilation (IPPV) to test the hypothesis that RSA normally functions to stabilize mean arterial blood pressure. Ten young volunteers were investigated during metronome-paced breathing and IPPV. Heart rate (ECG), mean arterial blood pressure and left stroke volume (finger arterial pressure curve) and right stroke volume (pulsed ultrasound Doppler) were recorded, while systemic and pulmonary blood flow were calculated beat-by-beat. Respiratory variations (high-frequency power, 0.15-0.40 Hz) in cardiovascular variables were estimated by spectral analysis. Phase angles and correlation were calculated by cross-spectral analysis. The magnitude of RSA was reduced from 4.9 bpm(2) (95% CI 3.0, 6.2) during metronome breathing to 2.8 bpm(2) (95% CI 1.1, 5.0) during IPPV (p = 0.03). Variations in mean arterial blood pressure were greater (2.3 mmHg(2) (95% CI 1.4, 3.9) during IPPV than during metronome breathing (1.0 mmHg(2) [95% CI 0.7, 1.3]) (p = 0.014). Respiratory variations in right and left stroke volumes were inversely related in the respiratory cycle during both metronome breathing and IPPV. RSA magnitude is lower and mean arterial blood pressure variability is greater during IPPV than during metronome breathing. We conclude that in healthy humans, RSA stabilizes mean arterial blood pressure at respiratory frequency.

  13. Effects of oxygen partial pressure on Li-air battery performance

    Science.gov (United States)

    Kwon, Hyuk Jae; Lee, Heung Chan; Ko, Jeongsik; Jung, In Sun; Lee, Hyun Chul; Lee, Hyunpyo; Kim, Mokwon; Lee, Dong Joon; Kim, Hyunjin; Kim, Tae Young; Im, Dongmin

    2017-10-01

    For application in electric vehicles (EVs), the Li-air battery system needs an air intake system to supply dry oxygen at controlled concentration and feeding rate as the cathode active material. To facilitate the design of such air intake systems, we have investigated the effects of oxygen partial pressure (≤1 atm) on the performance of the Li-air cell, which has not been systematically examined. The amounts of consumed O2 and evolved CO2 from the Li-air cell are measured with a custom in situ differential electrochemical gas chromatography-mass spectrometry (DEGC-MS). The amounts of consumed O2 suggest that the oxygen partial pressure does not affect the reaction mechanism during discharge, and the two-electron reaction occurs under all test conditions. On the other hand, the charging behavior varies by the oxygen partial pressure. The highest O2 evolution ratio is attained under 70% O2, along with the lowest CO2 evolution. The cell cycle life also peaks at 70% O2 condition. Overall, an oxygen partial pressure of about 0.5-0.7 atm maximizes the Li-air cell capacity and stability at 1 atm condition. The findings here indicate that the appropriate oxygen partial pressure can be a key factor when developing practical Li-air battery systems.

  14. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  15. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  16. Partial Pressures of Te2 and Thermodynamic Properties of Ga-Te System

    Science.gov (United States)

    Su, Ching-Hua; Curreri, Peter A. (Technical Monitor)

    2001-01-01

    The partial pressures of Te2 in equilibrium with Ga(1-x)Te(x) samples were measured by optical absorption technique from 450 to 1100 C for compositions, x, between 0.333 and 0.612. To establish the relationship between the partial pressure of Te, and the measured optical absorbance, the calibration runs of a pure Te sample were also conducted to determine the Beer's Law constants. The partial pressures of Te2 in equilibrium with the GaTe(s) and Ga2Te3(s)compounds, or the so-called three-phase curves, were established. These partial pressure data imply the existence of the Ga3Te4(s) compound. From the partial pressures of Te2 over the Ga-Te melts, partial molar enthalpy and entropy of mixing for Te were derived and they agree reasonable well with the published data. The activities of Te in the Ga-Te melts were also derived from the measured partial pressures of Te2. These data agree well with most of the previous results. The possible reason for the high activity of Te measured for x less than 0.60 is discussed.

  17. Resistance training controls arterial blood pressure in rats with L-NAME- induced hypertension.

    Science.gov (United States)

    Araujo, Ayslan Jorge Santos de; Santos, Anne Carolline Veríssimo dos; Souza, Karine dos Santos; Aires, Marlúcia Bastos; Santana-Filho, Valter Joviniano; Fioretto, Emerson Ticona; Mota, Marcelo Mendonça; Santos, Márcio Roberto Viana

    2013-04-01

    Arterial hypertension is a multifactorial chronic condition caused by either congenital or acquired factors. To evaluate the effects of Resistance Training (RT) on arterial pressure, and on vascular reactivity and morphology, of L-NAME-treated hypertensive rats. Male Wistar rats (200 - 250 g) were allocated into Sedentary Normotensive (SN), Sedentary Hypertensive (SH) and Trained Hypertensive (TH) groups. Hypertension was induced by adding L-NAME (40 mg/Kg) to the drinking water for four weeks. Arterial pressure was evaluated before and after RT. RT was performed using 50% of 1RM, 3 sets of 10 repetitions, 3 times per week for four weeks. Vascular reactivity was measured in rat mesenteric artery rings by concentration-response curves to sodium nitroprusside (SNP); phenylephrine (PHE) was also used for histological and stereological analysis. Resistance training inhibited the increase in mean and diastolic arterial pressures. Significant reduction was observed in Rmax (maximal response) and pD2 (potency) of PHE between SH and TH groups. Arteries demonstrated normal intima, media and adventitia layers in all groups. Stereological analysis demonstrated no significant difference in luminal, tunica media, and total areas of arteries in the SH and TH groups when compared to the SN group. Wall-to-lumen ratio of SH arteries was significantly different compared to SN arteries (parteries. RT was able to prevent an increase in blood pressure under the conditions in this study. This appears to involve a vasoconstrictor regulation mechanism and maintenance of luminal diameter in L-NAME induced hypertensive rats.

  18. Microwave measurements of water vapor partial pressure at high temperatures

    International Nuclear Information System (INIS)

    Latorre, V.R.

    1991-01-01

    One of the desired parameters in the Yucca Mountain Project is the capillary pressure of the rock comprising the repository. This parameter is related to the partial pressure of water vapor in the air when in equilibrium with the rock mass. Although there are a number of devices that will measure the relative humidity (directly related to the water vapor partial pressure), they generally will fail at temperatures on the order of 150C. Since thee author has observed borehole temperatures considerably in excess of this value in G-Tunnel at the Nevada Test Site (NTS), a different scheme is required to obtain the desired partial pressure data at higher temperatures. This chapter presents a microwave technique that has been developed to measure water vapor partial pressure in boreholes at temperatures up to 250C. The heart of the system is a microwave coaxial resonator whose resonant frequency is inversely proportional to the square root of the real part of the complex dielectric constant of the medium (air) filling the resonator. The real part of the dielectric constant of air is approximately equal to the square of the refractive index which, in turn, is proportional to the partial pressure of the water vapor in the air. Thus, a microwave resonant cavity can be used to measure changes in the relative humidity or partial pressure of water vapor in the air. Since this type of device is constructed of metal, it is able to withstand very high temperatures. The actual limitation is the temperature limit of the dielectric material in the cable connecting the resonator to its driving and monitoring equipment-an automatic network analyzer in our case. In the following sections, the theory of operation, design, construction, calibration and installation of the microwave diagnostics system is presented. The results and conclusions are also presented, along with suggestions for future work

  19. Anatomic renal artery branch microdissection to facilitate zero-ischemia partial nephrectomy.

    Science.gov (United States)

    Ng, Casey K; Gill, Inderbir S; Patil, Mukul B; Hung, Andrew J; Berger, Andre K; de Castro Abreu, Andre Luis; Nakamoto, Masahiko; Eisenberg, Manuel S; Ukimura, Osamu; Thangathurai, Duraiyah; Aron, Monish; Desai, Mihir M

    2012-01-01

    Robot-assisted and laparoscopic partial nephrectomies (PNs) for medial tumors are technically challenging even with the hilum clamped and, until now, were impossible to perform with the hilum unclamped. Evaluate whether targeted vascular microdissection (VMD) of renal artery branches allows zero-ischemia PN to be performed even for challenging medial tumors. A prospective cohort evaluation of 44 patients with renal masses who underwent robot-assisted or laparoscopic zero-ischemia PN either with anatomic VMD (group 1; n=22) or without anatomic VMD (group 2; n=22) performed by a single surgeon from April 2010 to January 2011. Zero-ischemia PN with VMD incorporates four maneuvers: (1) preoperative computed tomographic reconstruction of renal arterial branch anatomy, (2) anatomic dissection of targeted, tumor-specific tertiary or higher-order renal arterial branches, (3) neurosurgical aneurysm microsurgical bulldog clamp(s) for superselective tumor devascularization, and (4) transient, controlled reduction of blood pressure, if necessary. Baseline, perioperative, and postoperative data were collected prospectively. Group 1 tumors were larger (4.3 vs 2.6 cm; p=0.011), were more often hilar (41% vs 9%; p=0.09), were medial (59% and 23%; p=0.017), were closer to the hilum (1.46 vs 3.26 cm; p=0.0002), and had a lower C index score (2.1 vs 3.9; p=0.004) and higher RENAL nephrometry scores (7.7 vs 6.2; p=0.013). Despite greater complexity, no group 1 tumor required hilar clamping, and perioperative outcomes were similar to those of group 2: operating room time (4.7 and 4.1h), median blood loss (200 and 100ml), surgical margins for cancer (all negative), major complications (0% and 9%), and minor complications (18% and 14%). The median serum creatinine level was similar 2 mo postoperatively (1.2 and 1.3mg/dl). The study was limited by the relatively small sample size. Anatomic targeted dissection and superselective control of tumor-specific renal arterial branches facilitate

  20. Medial circumflex femoral artery flap for ischial pressure sore

    Directory of Open Access Journals (Sweden)

    Palanivelu S

    2009-01-01

    Full Text Available A new axial pattern flap based on the terminal branches of the medial circumflex femoral artery is described for coverage of ischial pressure sore. Based on the terminal branches of the transverse branch of medial circumflex femoral artery, which exit through the gap between the quadratus femoris muscle above and the upper border of adductor magnus muscle below, this fascio cutaneous flap is much smaller than the posterior thigh flap but extremely useful to cover ischeal pressure sores. The skin redundancy below the gluteal fold allows a primary closure of the donor defect. It can also be used in combination with biceps femoris muscle flap.

  1. Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

    Science.gov (United States)

    Kelly, Mark; Pettit, Donald

    2003-01-01

    A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

  2. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    International Nuclear Information System (INIS)

    Kyriacou, P A; Shafqat, K; Pal, S K

    2007-01-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO 2 ) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO 2 ) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO 2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  3. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Science.gov (United States)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  4. Energy harvesting from arterial blood pressure for powering embedded brain sensors

    Science.gov (United States)

    Nanda, Aditya; Karami, M. Amin

    2016-04-01

    This paper investigates energy harvesting from arterial blood pressure via the piezoelectric effect by using a novel streaked cylinder geometry for the purpose of powering embedded micro-sensors in the brain. Initially, we look at the energy harvested by a piezoelectric cylinder placed inside an artery acted upon by blood pressure. Such an arrangement would be tantamount to constructing a stent out of piezoelectric materials. A stent is a cylinder placed in veins and arteries to prevent obstruction in blood flow. The governing equations of a conductor coated piezoelectric cylinder are obtained using Hamilton's principle. Pressure acting in arteries is radially directed and this is used to simplify the modal analysis and obtain the transfer function relating pressure to the induced voltage across the surface of the harvester. The power harvested by the cylindrical harvester is obtained for different shunt resistances. Radially directed pressure occurs elsewhere and we also look at harvesting energy from oil flow in pipelines. Although the energy harvested by the cylindrical energy harvester is significant at resonance, the natural frequency of the system is found to be very high. To decrease the natural frequency, we propose a novel streaked stent design by cutting it along the length, transforming it to a curved plate and decreasing the natural frequency. The governing equations corresponding to the new geometry are derived using Hamilton's principle and modal analysis is used to obtain the transfer function.

  5. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  6. Flow-related Right Ventricular - Pulmonary Arterial Pressure Gradients during Exercise.

    Science.gov (United States)

    Wright, Stephen P; Opotowsky, Alexander R; Buchan, Tayler A; Esfandiari, Sam; Granton, John T; Goodman, Jack M; Mak, Susanna

    2018-06-06

    The assumption of equivalence between right ventricular and pulmonary arterial systolic pressure is fundamental to several assessments of right ventricular or pulmonary vascular hemodynamic function. Our aims were to 1) determine whether systolic pressure gradients develop across the right ventricular outflow tract in healthy adults during exercise, 2) examine the potential correlates of such gradients, and 3) consider the effect of such gradients on calculated indices of right ventricular function. Healthy untrained and endurance-trained adult volunteers were studied using right-heart catheterization at rest and during submaximal cycle ergometry. Right ventricular and pulmonary artery pressures were simultaneously transduced, and cardiac output was determined by thermodilution. Systolic pressures, peak and mean gradients, and indices of chamber, vascular, and valve function were analyzed offline. Summary data are reported as mean ± standard deviation or median [interquartile range]. No significant right ventricular outflow tract gradients were observed at rest (mean gradient = 4 [3-5] mmHg), and calculated effective orifice area was 3.6±1.0 cm2. Right ventricular systolic pressure increases during exercise were greater than that of pulmonary artery systolic pressure. Accordingly, mean gradients developed during light exercise (8 [7-9] mmHg) and increased during moderate exercise (12 [9-14] mmHg, p < 0.001). The magnitude of the mean gradient was linearly related to cardiac output (r2 = 0.70, p < 0.001). In healthy adults without pulmonic stenosis, systolic pressure gradients develop during exercise, and the magnitude is related to blood flow rate.

  7. Selective Arterial Clamping Versus Hilar Clamping for Minimally Invasive Partial Nephrectomy.

    Science.gov (United States)

    Yezdani, Mona; Yu, Sue-Jean; Lee, David I

    2016-05-01

    Partial nephrectomy has become an accepted treatment of cT1 renal masses as it provides improved long-term renal function compared to radical nephrectomy (Campbell et al. J Urol. 182:1271-9, 2009). Hilar clamping is utilized to help reduce bleeding and improve visibility during tumor resection. However, concern over risk of kidney injury with hilar clamping has led to new techniques to reduce length of warm ischemia time (WIT) during partial nephrectomy. These techniques have progressed over the years starting with early hilar unclamping, controlled hypotension during tumor resection, selective arterial clamping, minimal margin techniques, and off-clamp procedures. Selective arterial clamping has progressed significantly over the years. The main question is what are the exact short- and long-term renal effects from increasing clamp time. Moreover, does it make sense to perform these more time-consuming or more complex procedures if there is no long-term preservation of kidney function? More recent studies have shown no difference in renal function 6 months from surgery when selective arterial clamping or even hilar clamping is employed, although there is short-term improved decline in estimated glomerular filtration rate (eGFR) with selective clamping and off-clamp techniques (Komninos et al. BJU Int. 115:921-8, 2015; Shah et al. 117:293-9, 2015; Kallingal et al. BJU Int. doi: 10.1111/bju.13192, 2015). This paper reviews the progression of total hilar clamping to selective arterial clamping (SAC) and the possible difference its use makes on long-term renal function. SAC may be attempted based on surgeon's decision-making, but may be best used for more complex, larger, more central or hilar tumors and in patients who have renal insufficiency at baseline or a solitary kidney.

  8. Perinatal taurine exposure affects adult arterial pressure control

    Science.gov (United States)

    Roysommuti, Sanya; Wyss, J. Michael

    2012-01-01

    Taurine is an abundant free amino acid found in mammalian cells that contributes to many physiologic functions from that of a simple cell osmolyte to a programmer of adult health and disease. Taurine’s contribution extends from conception throughout life, but its most critical exposure period is during perinatal life. In adults, taurine supplementation prevents or alleviates cardiovascular disease and related complications. In contrast, low taurine consumption coincides with increased risk of cardiovascular disease, obesity and type II diabetes. This review focuses on the effects that altered perinatal taurine exposure has on long-term mechanisms that control adult arterial blood pressure and could thereby contribute to arterial hypertension through its ability to program these cardiovascular regulatory mechanisms very early in life. The modifications of these mechanisms can last a lifetime and transfer to the next generation, suggesting that epigenetic mechanisms underlie the changes. The ability of perinatal taurine exposure to influence arterial pressure control mechanisms and hypertension in adult life appears to involve the regulation of growth and development, the central and autonomic nervous system, the renin-angiotensin system, glucose-insulin interaction and changes to heart, blood vessels and kidney function. PMID:23070226

  9. Allergic rhinitis and arterial blood pressure: a population-based study.

    Science.gov (United States)

    Sakallioglu, O; Polat, C; Akyigit, A; Cetiner, H; Duzer, S

    2018-05-01

    To investigate the likelihood of allergic rhinitis and potential co-morbidities, and to assess whether allergic rhinitis is associated with arterial blood pressure and hypertension. In this population-based study, 369 adults with allergic rhinitis and asthma were assessed via a questionnaire and immunoglobulin E levels. There were four groups: control (n = 90), allergic rhinitis (n = 99), asthma (n = 87) and hypertension (n = 93). Arterial blood pressure was measured in all groups. There were no significant differences in systolic or diastolic blood pressure between males and females in any group. Pairwise comparisons revealed no significant differences between: the control and allergic rhinitis groups, the control and asthma groups, or the allergic rhinitis and asthma groups. The systolic and diastolic blood pressure values of males and females were significantly higher in the hypertension group than the allergic rhinitis group. There were no significant differences in systolic blood pressure or diastolic blood pressure for seasonal and perennial allergic rhinitis patients. Rhinitis was not associated with increased blood pressure. Allergic rhinitis can coincide with asthma and hypertension. The findings do not support the need for blood pressure follow up in allergic rhinitis patients.

  10. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  11. Recommended practice for process sampling for partial pressure analysis

    International Nuclear Information System (INIS)

    Blessing, James E.; Ellefson, Robert E.; Raby, Bruce A.; Brucker, Gerardo A.; Waits, Robert K.

    2007-01-01

    This Recommended Practice describes and recommends various procedures and types of apparatus for obtaining representative samples of process gases from >10 -2 Pa (10 -4 Torr) for partial pressure analysis using a mass spectrometer. The document was prepared by a subcommittee of the Recommended Practices Committee of the American Vacuum Society. The subcommittee was comprised of vacuum users and manufacturers of mass spectrometer partial pressure analyzers who have practical experience in the sampling of process gas atmospheres

  12. Strength training reduces arterial blood pressure but not sympathetic neural activity in young normotensive subjects

    Science.gov (United States)

    Carter, Jason R.; Ray, Chester A.; Downs, Emily M.; Cooke, William H.

    2003-01-01

    The effects of resistance training on arterial blood pressure and muscle sympathetic nerve activity (MSNA) at rest have not been established. Although endurance training is commonly recommended to lower arterial blood pressure, it is not known whether similar adaptations occur with resistance training. Therefore, we tested the hypothesis that whole body resistance training reduces arterial blood pressure at rest, with concomitant reductions in MSNA. Twelve young [21 +/- 0.3 (SE) yr] subjects underwent a program of whole body resistance training 3 days/wk for 8 wk. Resting arterial blood pressure (n = 12; automated sphygmomanometer) and MSNA (n = 8; peroneal nerve microneurography) were measured during a 5-min period of supine rest before and after exercise training. Thirteen additional young (21 +/- 0.8 yr) subjects served as controls. Resistance training significantly increased one-repetition maximum values in all trained muscle groups (P < 0.001), and it significantly decreased systolic (130 +/- 3 to 121 +/- 2 mmHg; P = 0.01), diastolic (69 +/- 3 to 61 +/- 2 mmHg; P = 0.04), and mean (89 +/- 2 to 81 +/- 2 mmHg; P = 0.01) arterial blood pressures at rest. Resistance training did not affect MSNA or heart rate. Arterial blood pressures and MSNA were unchanged, but heart rate increased after 8 wk of relative inactivity for subjects in the control group (61 +/- 2 to 67 +/- 3 beats/min; P = 0.01). These results indicate that whole body resistance exercise training might decrease the risk for development of cardiovascular disease by lowering arterial blood pressure but that reductions of pressure are not coupled to resistance exercise-induced decreases of sympathetic tone.

  13. Clinical observations on the effect of carotid artery occlusion on cerebral blood flow mapped by xenon computed tomography and its correlation with carotid artery back pressure

    International Nuclear Information System (INIS)

    Steed, D.L.; Webster, M.W.; DeVries, E.J.; Jungreis, C.A.; Horton, J.A.; Sehkar, L.; Yonas, H.

    1990-01-01

    Xenon computed tomographic cerebral blood flow mapping was correlated with internal carotid artery stump pressures and clinical neurologic assessment during temporary internal carotid artery occlusion. One hundred fourteen patients with skull base tumors or intracranial aneurysms potentially requiring carotid resection or ligation underwent angiography, xenon CT cerebral blood flow mapping, and internal carotid artery blood pressure monitoring. The internal carotid artery was then temporarily occluded with a balloon catheter, stump pressure was measured through the catheter, and the xenon CT cerebral blood flow mapping was repeated. Adequate xenon CT cerebral blood flow was defined as greater than 30 cc/100 gm/min. All patients had normal xenon CT cerebral blood flow before internal carotid artery occlusion. During internal carotid artery occlusion, xenon CT cerebral blood flow was found to be normal (group I, 40 patients), globally reduced but still within the normal range (group II, 50 patients), or low in the distribution of the ipsilateral middle cerebral artery (group III, 13 patients). With balloon occlusion, an immediate neurologic deficit developed in 11 patients (9%) requiring deflation of the balloon preceding xenon CT cerebral blood flow measurement (group IV). In group I internal carotid artery blood pressure was 128 mm Hg. (range 85 to 171 mm Hg) with stump pressure 86 mm Hg (range 46 to 125 mm Hg). In group II internal carotid artery blood pressure was 130 mm Hg. (range 78 to 199 mm Hg), with stump pressure 86 mm Hg (range 31 to 150 mm Hg)

  14. Contribution of the Arterial System and the Heart to Blood Pressure during Normal Aging - A Simulation Study.

    Science.gov (United States)

    Maksuti, Elira; Westerhof, Nico; Westerhof, Berend E; Broomé, Michael; Stergiopulos, Nikos

    2016-01-01

    During aging, systolic blood pressure continuously increases over time, whereas diastolic pressure first increases and then slightly decreases after middle age. These pressure changes are usually explained by changes of the arterial system alone (increase in arterial stiffness and vascular resistance). However, we hypothesise that the heart contributes to the age-related blood pressure progression as well. In the present study we quantified the blood pressure changes in normal aging by using a Windkessel model for the arterial system and the time-varying elastance model for the heart, and compared the simulation results with data from the Framingham Heart Study. Parameters representing arterial changes (resistance and stiffness) during aging were based on literature values, whereas parameters representing cardiac changes were computed through physiological rules (compensated hypertrophy and preservation of end-diastolic volume). When taking into account arterial changes only, the systolic and diastolic pressure did not agree well with the population data. Between 20 and 80 years, systolic pressure increased from 100 to 122 mmHg, and diastolic pressure decreased from 76 to 55 mmHg. When taking cardiac adaptations into account as well, systolic and diastolic pressure increased from 100 to 151 mmHg and decreased from 76 to 69 mmHg, respectively. Our results show that not only the arterial system, but also the heart, contributes to the changes in blood pressure during aging. The changes in arterial properties initiate a systolic pressure increase, which in turn initiates a cardiac remodelling process that further augments systolic pressure and mitigates the decrease in diastolic pressure.

  15. Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording

    NARCIS (Netherlands)

    Imholz, B. P.; Langewouters, G. J.; van Montfrans, G. A.; Parati, G.; van Goudoever, J.; Wesseling, K. H.; Wieling, W.; Mancia, G.

    1993-01-01

    We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record

  16. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  17. Method and apparatus for monitoring oxygen partial pressure in air masks

    Science.gov (United States)

    Kelly, Mark E. (Inventor); Pettit, Donald R. (Inventor)

    2006-01-01

    Method and apparatus are disclosed for monitoring an oxygen partial pressure in an air mask and providing a tactile warning to the user. The oxygen partial pressure in the air mask is detected using an electrochemical sensor, the output signal from which is provided to a comparator. The comparator compares the output signal with a preset reference value or range of values representing acceptable oxygen partial pressures. If the output signal is different than the reference value or outside the range of values, the air mask is vibrated by a vibrating motor to alert the user to a potentially hypoxic condition.

  18. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Agnes S. Meidert

    2018-01-01

    Full Text Available Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent or continuous readings. Most commonly, an occluding upper arm cuff is used for intermittent non-invasive monitoring. BP values are then obtained either manually (by auscultation of Korotkoff sounds or palpation or automatically (e.g., by oscillometry. For continuous non-invasive BP monitoring, the volume clamp method or arterial applanation tonometry can be used. Both techniques enable the arterial waveform and BP values to be obtained continuously. This article describes the different techniques for non-invasive BP measurement, their advantages and limitations, and their clinical applicability.

  19. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Shafqat, K [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Pal, S K [St Andrew' s Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, CM1 7ET (United Kingdom)

    2007-10-15

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO{sub 2}) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO{sub 2}) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO{sub 2} sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures

  20. Chronic binge alcohol consumption during pregnancy alters rat maternal uterine artery pressure response.

    Science.gov (United States)

    Naik, Vishal D; Lunde-Young, Emilie R; Davis-Anderson, Katie L; Orzabal, Marcus; Ivanov, Ivan; Ramadoss, Jayanth

    2016-11-01

    We aimed to investigate pressure-dependent maternal uterine artery responses and vessel remodeling following gestational binge alcohol exposure. Two groups of pregnant rats were used: the alcohol group (28.5% wt/v, 6.0 g/kg, once-daily orogastric gavage in a binge paradigm between gestational day (GD) 5-19) and pair-fed controls (isocalorically matched). On GD20, excised, pressurized primary uterine arteries were studied following equilibration (60 mm Hg) using dual chamber arteriograph. The uterine artery diameter stabilized at 20 mm Hg, showed passive distension at 40 mm Hg, and redeveloped tone at 60 mm Hg. An alcohol effect (P = 0.0025) was observed on the percent constriction of vessel diameter with greater pressure-dependent myogenic constriction. Similar alcohol effect was noted with lumen diameter response (P = 0.0020). The percent change in media:lumen ratio was higher in the alcohol group (P alcohol affects pressure-induced uterine artery reactivity, inward-hypotrophic remodeling, and adaptations critical for nutrient delivery to the fetus. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Variable day/night bias in 24-h non-invasive finger pressure against intrabrachial artery pressure is removed by waveform filtering and level correction

    NARCIS (Netherlands)

    Westerhof, Berend E.; Guelen, Ilja; Parati, Gianfranco; Groppelli, Antonella; van Montfrans, Gert A.; Wieling, Wouter; Wesseling, Karel H.; Bos, Willem Jan W.

    2002-01-01

    Background Twenty-four-hour finger arterial pressure (FAP) recordings show a negative bias against intrabrachial artery pressure (BAP) and the bias is greater during the night thereby overestimating the nocturnal blood pressure dip. We have available a methodology with which to reconstruct BAP from

  2. Clinical outcome of patients with familial hypercholesterolemia and coronary artery disease undergoing partial ileal bypass surgery

    Directory of Open Access Journals (Sweden)

    Jaqueline Scholz Issa

    2000-07-01

    Full Text Available Familial hypercholesterolemia is characterized by high serum levels of total cholesterol and LDL-cholesterol. It may be homozygous or heterozygous. In homozygous patients, LDL-cholesterol levels range from 500 to 1000mg/dL and coronary artery disease is precocious, usually manifesting itself between the 2nd and 3rd decades of life. The diagnosis is often made by the presence of xanthoma tuberosum and tendinous xanthomas that appear between the 1st and 2nd decades of life. The use of high doses of statins or even unusual procedures (apheresis, partial ileal bypass surgery, liver transplantation, gene therapy, or both, is necessary for increasing survival and improving quality of life, because a reduction in cholesterol levels is essential for stabilizing the coronary artery disease and reducing xanthomas. We report our experience with 3 patients with xanthomatous familial hypercholesterolemia and coronary artery disease, who underwent partial ileal bypass surgery. Their follow-up over the years (approximately 8 years showed a mean 30% reduction in total cholesterol, with a significant reduction in the xanthomas and stabilization of the coronary artery disease.

  3. Pressures of Partial Crystallization of Magmas Along Transforms: Implications for Crustal Accretion

    Science.gov (United States)

    Scott, J. L.; Zerda, C.; Brown, D.; Ciaramitaro, S. C.; Barton, M.

    2016-12-01

    Plate spreading at mid-ocean ridges is responsible for the creation of most of the crust on earth. The ridge system is very complex and many questions remain unresolved. Among these is the nature of magma plumbing systems beneath transform faults. Pervious workers have suggested that increased conductive cooling along transforms promotes higher pressures of partial crystallization, and that this explains the higher partial pressures of crystallization inferred for magmas erupted along slow spreading ridges compared to magmas erupted along faster spreading ridges. To test this hypothesis, we undertook a detailed analysis of pressures of partial crystallization for magmas erupted at 3 transforms along the fast to intermediate spreading East Pacific Rise(Blanco, Clipperton, and Siqueiros) and 3 transforms along the slow spreading Mid Atlantic Ridge(Famous Transform B, Kane, and 15°20'N). Pressures of partial crystallization were calculated from the compositions of glasses (quenched liquids) lying along the P (and T) dependent olivine, plagioclase, and augite cotectic using the method described by Kelley and Barton (2008). Published analyses of mid-ocean ridge basalt glasses sampled from these transforms and surrounding ridge segments were used as input data. Samples with anomalous chemical compositions and samples that yielded pressures associated with unrealistically large uncertainties were filtered out of the database. The pressures of partial crystallization for the remaining 916 samples ranged from 0 to 520 MPa with the great majority ( 95%) of sample returning pressures of less than 300 MPa. Pressures of 300 MPa) are associated with a small number of samples from the Pacific segments. Except for the Blanco, pressures of partial crystallization do not increase as transforms are approached. These observations contrast with those of previous workers, who reported anomalously high pressures (up to 1000 MPa) for a large number of samples erupted near both Atlantic

  4. Retinal vessel diameter and estimated cerebrospinal fluid pressure in arterial hypertension: the Beijing Eye Study.

    Science.gov (United States)

    Jonas, Jost B; Wang, Ningli; Wang, Shuang; Wang, Ya Xing; You, Qi Sheng; Yang, Diya; Wei, Wen Bin; Xu, Liang

    2014-09-01

    Hypertensive retinal microvascular abnormalities include an increased retinal vein-to-artery diameter ratio. Because central retinal vein pressure depends on cerebrospinal fluid pressure (CSFP), we examined whether the retinal vein-to-artery diameter ratio and other retinal hypertensive signs are associated with CSFP. Participants of the population-based Beijing Eye Study (n = 1,574 subjects) underwent measurement of the temporal inferior and superior retinal artery and vein diameter. CSFP was calculated as 0.44 × body mass index (kg/m(2)) + 0.16 × diastolic blood pressure (mm Hg) - 0.18 × age (years) - 1.91. Larger retinal vein diameters and higher vein-to-artery diameter ratios were significantly associated with higher estimated CSFP (P = 0.001) in multivariable analysis. In contrast, temporal inferior retinal arterial diameter was marginally associated (P = 0.03) with estimated CSFP, and temporal superior artery diameter was not significantly associated (P = 0.10) with estimated CSFP; other microvascular abnormalities, such as arteriovenous crossing signs, were also not significantly associated with estimated CSFP. In a reverse manner, higher estimated CSFP as a dependent variable in the multivariable analysis was associated with wider retinal veins and higher vein-to-artery diameter ratio. In the same model, estimated CSFP was not significantly correlated with retinal artery diameters or other retinal microvascular abnormalities. Correspondingly, arterial hypertension was associated with retinal microvascular abnormalities such as arteriovenous crossing signs (P = 0.003), thinner temporal retinal arteries (P arterial hypertension, an increased retinal vein-to-artery diameter ratio depends on elevated CSFP, which is correlated with blood pressure. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Intravenous clonidine administration and its ability to reduce pulmonary arterial pressure in patients undergoing heart surgery

    Directory of Open Access Journals (Sweden)

    Benedito Barbosa João

    2014-01-01

    Full Text Available Objective: Evaluate the ability of clonidine to reduce pulmonary arterial pressure in patients with pulmonary hypertension undergoing heart surgery, either by reducing the pressure values from the direct measurement of pulmonary arterial pressure or by reducing or eliminating the need for intraoperative dobutamine and nitroprusside. Method: Randomized, double-blind, placebo-controlled, comparative study conducted in 30 patients with pulmonary arterial hypertension type 2 undergoing cardiac surgery. Mean pulmonary arterial pressure and dosage of dobutamine and sodium nitroprusside were assessed four times: before intravenous administration of clonidine (2 μg/kg or placebo (T0, 30 min after tested treatment and before cardiopulmonary bypass (T1, immediately after CPB (T2, 10 min after protamine injection (T3. Results: There were no significant differences regarding mean pulmonary arterial pressure at any time of evaluation. There was no significant difference between groups regarding other variables, such as mean systemic arterial pressure, heart rate, total dose of dobutamine, total dose of sodium nitroprusside, and need for fentanyl. Conclusion: Data analysis from patients included in this study allows us to conclude that intravenous clonidine (2 μg/kg was not able to reduce the mean pulmonary arterial pressure in patients with pulmonary hypertension in group 2 (pulmonary venous hypertension, undergoing heart surgery, or reduce or eliminate the need for intraoperative administration of dobutamine and sodium nitroprusside. Keywords: Clonidine, Pulmonary hypertension, Heart surgery

  6. The Effects of Synthetic Cannabinoids on Alveolar-Arterial Oxygen Gradient

    Directory of Open Access Journals (Sweden)

    Egemen Kucuk

    2016-09-01

    Full Text Available Aim: Synthetic cannabinoids are chemicals that produce several marijuana-like effects in humans. Aim of this study is to investigate the effects of synthetic cannabinoids on to alveolar-arterial oxygen gradient. Material and Method: A total of 112 patients, who admitted directly to emergency clinic with synthetic cannabinoid usage, were determined between February 2014 and August 2014. Blood gases of 41 patients were determined as arterial blood gases on room air, and included in to study. Patients were evaluated according to age, sex, decade, partial pressure of arterial oxygen, partial pressure of arterial carbon dioxide, pH, bicarbonate, metabolic status, age consistent expected alveolar-arterial oxygen gradient and calculated alveolar-arterial oxygen gradient. Results: Synthetic cannabinoid using was higher in males, mean age of patients was 23.32±6.14 years. Number of patients in the third decade were significantly higher than the other decades. The calculated alveolar-arterial oxygen gradient value of patients was significantly higher than age consistent expected alveolar-arterial oxygen gradient value. Respiratory acidosis, was significantly higher than the other types of the metabolic disorders. The best cutoff point for calculated alveolar-arterial oxygen gradient was 12.70, with sensitivity of 90% and specifity of 85%. Area under curve was 0.70 for calculated alveolar-arterial oxygen gradient. Discussion: The value of alveolar-arterial oxygen gradient has been increased due to synthetic cannabinoid usage. This can be used as a supportive parameter in the diagnosis of synthetic cannabinoid usage.

  7. Non-invasive multiwavelength photoplethysmography under low partial pressure of oxygen.

    Science.gov (United States)

    Fang, Yung Chieh; Tai, Cheng-Chi

    2016-08-01

    A reduction in partial pressure of oxygen in the environment may be caused by a gain in altitude, which reduces the atmospheric pressure; it may also be caused by the carbon dioxide generated from breathing in an enclosed space. Does inhaling oxygen of lower partial pressure affect the oxygen-carrying function of haemoglobin in vivo? This study uses non-invasive multiwavelength photoplethysmography to measure the effects that inhaling this type of oxygen can have on the plethysmography of the appendages of the body (fingertips). The results indicate that under low partial pressure of oxygen, be it the result of a gain in carbon dioxide concentration or altitude, the change in visible light absorption is the biggest for short wavelengths (approximately 620 or 640 nm) near deoxyhaemoglobin, which has higher absorption coefficient. Moreover, increasing carbon dioxide concentration from 5000 to 10,000 ppm doubly reduces the absorption rate of these short wavelengths.

  8. Monitoring in microvascular tissue transfer by measurement of oxygen partial pressure: four years experience with 125 microsurgical transplants.

    Science.gov (United States)

    Jonas, René; Schaal, Thomas; Krimmel, Michael; Gülicher, Dirk; Reinert, Siegmar; Hoffmann, Jürgen

    2013-06-01

    In a prospective study, the characteristics and benefit of an invasive measurement of oxygen partial pressure (pO(2)) with the aid of a polarographic sensor were investigated in 125 microsurgical reconstructions of the head and neck area over a period of 45 months. Measurements were performed over 96 h in eight different types of microsurgically revascularized flaps for extra- and intraoral reconstructions and were evaluated separately for each flap type. Of 125 reconstructions the system indicated malperfusion in 18 cases. Salvage surgery was performed in 17 cases due to venous thrombosis (6 cases), arterial thrombosis (3 cases), a combination of arterial and venous thrombosis (2 cases), rheological problems (3 cases), venous insufficiency by hematoma (2 cases) and kinking of vessels (1 case). In 10 cases salvage surgery was successful, 7 flaps were lost despite salvage surgery. In all these cases, the polarographic probe indicated the necessity of salvage surgery correctly. After 96 h no malperfusion was seen. Postoperatively, a common and characteristic development of the oxygen partial pressure in different types of flaps was seen. Initially, a clear increase of pO(2) could be measured. During 96 h, a slow decrease of pO(2) was observed. In conclusion polarographic measurement of pO(2) can be an excellent apparative supplement for the postoperative clinical control of microsurgically revascularized transplants. In buried flaps, this technique represents the only reliable method for transplant monitoring. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. The relation between in vivo ethylene production and oxygen partial pressure

    NARCIS (Netherlands)

    Sanders, M.G.; Wild, de H.P.J.

    2003-01-01

    Modelling in vivo ethylene production rate in relation to O2 partial pressure was used to improve understanding of enzyme kinetics of 1-aminocyclopropane-1-carboxylate oxidase (ACC oxidase). Tomato fruit were stored in an extensive range of O2 partial pressures at 8, 13 and 18 °C. Ethylene

  10. The effects of cigarette smoking on intraocular pressure and arterial ...

    African Journals Online (AJOL)

    This study was designed to determine the effects of cigarette Smoking on intra ocular pressure and arterial blood pressure of normotensive young male adults. Fifty male students (who met the screening conditions and devoid of obvious ocular pathology and systemic diseases and nonsmokers) had their intra ocular ...

  11. Oxygen partial pressure effects on the magnetron sputtered WO3 films

    International Nuclear Information System (INIS)

    Muğlu, G Merhan; Gür, E

    2016-01-01

    Electrochromism is changing color of a substance in response to the applied an external electric field and the phenomenon is reversible. WO 3 is very attractive material due to its electrochromic properties as well as it is also attractive for many different applications such as gas sensors, phosphorous screen, textile, glass industry. In this study, it is aimed to provide optimization of the optical and structural characteristics of WO 3 by changing the growth parameters mainly the oxygen partial pressure. The partial pressure of oxygen was changed with increments of 0.7 mTorr. For the analysis, X-ray Diffraction (XRD), absorption, Raman spectroscopy measurements were used. When O 2 gas increased, peaks belong to the WO 3 was observed in XRD patterns at the 2 theta angles of 23.0, 11.0, 23.5 and 28.5 angles corresponding to the (002), (020) and (220) planes, respectively. This shows that there is a significant effect of increasing O 2 partial pressure in the formation of WO 3 films. The bandgap energy of the WO 3 thin films are found to be around 3.0 eV. Raman measurements showed vibrational modes of W-O-W stretching and bending modes which shows small shifts depending on the partial pressures of the O 2 . Obtained results indicated that better crystal structure is obtained with higher O 2 gas partial pressure. (paper)

  12. Perfusion of veins at arterial pressure increases the expression of KLF5 and cell cycle genes in smooth muscle cells

    International Nuclear Information System (INIS)

    Amirak, Emre; Zakkar, Mustafa; Evans, Paul C.; Kemp, Paul R.

    2010-01-01

    Vascular smooth muscle cell (VSMC) proliferation remains a major cause of veno-arterial graft failure. We hypothesised that exposure of venous SMCs to arterial pressure would increase KLF5 expression and that of cell cycle genes. Porcine jugular veins were perfused at arterial or venous pressure in the absence of growth factors. The KLF5, c-myc, cyclin-D and cyclin-E expression were elevated within 24 h of perfusion at arterial pressure but not at venous pressure. Arterial pressure also reduced the decline in SM-myosin heavy chain expression. These data suggest a role for KLF5 in initiating venous SMCs proliferation in response to arterial pressure.

  13. Downstream Hepatic Arterial Blood Pressure Changes Caused by Deployment of the Surefire AntiReflux Expandable Tip

    International Nuclear Information System (INIS)

    Rose, Steven C.; Kikolski, Steven G.; Chomas, James E.

    2013-01-01

    Purpose: The purpose of this work was to evaluate blood pressure changes caused by deployment of the Surefire antireflux expandable tip. The pressure measurements are relevant because they imply changes in hepatoenteric arterial blood flow within this liver compartment during hepatic artery delivery of cytotoxic agents. Methods: After positioning the Surefire antireflux system in the targeted hepatic artery, blood pressure was obtained initially with the tip collapsed (or through a femoral artery sheath), then again after the tip was expanded before chemoembolization or yttrium 90 ( 90 Y) radioembolization. Results: Eighteen patients with liver malignancy underwent 29 procedures in 29 hepatic arteries (3 common hepatic, 22 lobar, 4 segmental). Systolic, diastolic, and mean blood pressure were all decreased by a mean of 29 mm Hg (p = 0.000004), 14 mm Hg (p = 0.0000004), and 22 mm Hg (p = 0.00000001), respectively. Conclusion: When the Surefire expandable tip is deployed to prevent retrograde reflux of agents, it also results in a significant decrease in blood pressure in the antegrade distribution, potentially resulting in hepatopedal blood flow in vessels that are difficult to embolize, such as the supraduodenal arteries

  14. LB03.04: SPHYGMOMANOMETER CUFF CONSTRUCTION AND MATERIALS AFFECT TRANSMISSION OF PRESSURE FROM CUFF TO ARTERIAL WALL. FINITE ELEMENT ANALYSIS OF HUMAN PRESSURE MEASUREMENTS AND DICOM DATA.

    Science.gov (United States)

    Lewis, P; Naqvi, S; Mandal, P; Potluri, P

    2015-06-01

    Sphygmomanometer cuff pressure during deflation is assumed to equal systolic arterial pressure at the point of resumption of flow. Previous studies demonstrated that pressure decreases with increasing depth of soft tissues whilst visco-elastic characteristics of the arm tissue cause spatial and temporal variation in pressure magnitude. These generally used non-anatomical axisymmetrical arm simulations without incorporating arterial pressure variation. We used data from a volunteer's Magnetic Resonance (MR) arm scan and investigated the effect of variations in cuff materials and construction on the simulated transmission of pressure from under the cuff to the arterial wall under sinusoidal flow conditions. Pressure was measured under 8 different cuffs using Oxford Pressure Monitor Sensors placed at 90 degrees around the mid upper arm of a healthy male. Each cuff was inflated 3 times to 155 mmHg and then deflated to zero with 90 seconds between inflations. Young's modulus, flexural rigidity and thickness of each cuff was measured.Using DICOM data from the MR scan of the arm, a 3D model was derived using ScanIP and imported into Abaqus for Finite Element Analysis (FEA). Published mechanical properties of arm tissues and geometric non-linearity were assumed. The measured sub-cuff pressures were applied to the simulated arm and pressure was calculated around the brachial arterial wall. which was loaded with a sinusoidal pressure of 125/85 mmHg. FEA estimates of pressure around the brachial artery cuffs varied by up to 27 mmHg SBP and 17 mmHg DBP with different cuffs. Pressures within the cuffs varied up to 27 mmHg. Pressure transmission from the cuff to the arterial surface achieved a 95% transmission ratio with one rubber-bladdered cuff but varied between 76 and 88% for the others. Non-uniform pressure distribution around the arterial wall was strongly related to cuff fabric elastic modulus. Identical size cuffs with a separate rubber bladder produced peri-arterial

  15. Report on ISS Oxygen Production, Resupply, and Partial Pressure Management

    Science.gov (United States)

    Schaezler, Ryan; Ghariani, Ahmed; Leonard, Daniel; Lehman, Daniel

    2011-01-01

    The majority of oxygen used on International Space Station (ISS) is for metabolic support and denitrogenation procedures prior to Extra-Vehicular Activities. Oxygen is supplied by various visiting vehicles such as the Progress and Shuttle in addition to oxygen production capability on both the United States On-Orbit Segment (USOS) and Russian Segment (RS). To maintain a habitable atmosphere the oxygen partial pressure is controlled between upper and lower bounds. The full range of the allowable oxygen partial pressure along with the increased ISS cabin volume is utilized as a buffer allowing days to pass between oxygen production or direct addition of oxygen to the atmosphere from reserves. This paper summarizes amount of oxygen supplied and produced from all of the sources and describes past experience of managing oxygen partial pressure along with the range of management options available to the ISS.

  16. Investigation Of Arterial Blood Pressure Level And Metabolic Indices In Patients With Arterial Hypertension At Pharmacotherapy With Antihypertensive Medicines Of Various Chemical Structure

    Directory of Open Access Journals (Sweden)

    G.Kh. Glybochko

    2009-12-01

    Full Text Available The research goal is to carry on the comparative analysis of medicines of various chemical structure, Telmisar-tan and Bisoprolol, and to reveal their effect on the arterial blood pressure level and the indices of various metabolic processes in patients with arterial hypertension. 60 out-patients with arterial hypertension (stage II risk III both males and females aged 33-55 have been under study taking Telmisartan and Bisoprolol for 3 months. While treating the patients the arterial blood pressure level control and biochemical investigations for determination the indices of metabolic processes have been carried out. The investigated medications have provided the decrease of systolic and diastolic arterial pressure parameters, the increase of concentration of total and ionized calcium, chlorine ions, urea and total bilirubin in blood plasma. Therapy with Telmisartan has shown more significant increase of potassium level in erythro-cytes, decrease of levels of natrium, glucose, glycolized hemoglobin and triglycerides and increased contents of alani-naminotransferase and aspartataminotransferase. The course of therapy with Bisoprolol has restored the normal level of magnesium in blood plasma, has not have any influence on carbohydrate and lipid metabolism, increased the level of alaninaminotransferase and significantly increased the contents of total and ionized calcium, urea and creatinine. 3-months therapy with Telmisartan and Bisoprolol has proved the decrease of systolic and diastolic arterial pressure in patients with arterial hypertension. The medications under study have had active and variable effects on metabolic indices

  17. Numerical modeling of dynamics of heart rate and arterial pressure during passive orthostatic test

    Science.gov (United States)

    Ishbulatov, Yu. M.; Kiselev, A. R.; Karavaev, A. S.

    2018-04-01

    A model of human cardiovascular system is proposed to describe the main heart rhythm, influence of autonomous regulation on frequency and strength of heart contractions and resistance of arterial vessels; process of formation of arterial pressure during systolic and diastolic phases; influence of respiration; synchronization between loops of autonomous regulation. The proposed model is used to simulate the dynamics of heart rate and arterial pressure during passive transition from supine to upright position. Results of mathematical modeling are compared to original experimental data.

  18. Effect of upper body position on arterial stiffness: influence of hydrostatic pressure and autonomic function.

    Science.gov (United States)

    Schroeder, Elizabeth C; Rosenberg, Alexander J; Hilgenkamp, Thessa I M; White, Daniel W; Baynard, Tracy; Fernhall, Bo

    2017-12-01

    To evaluate changes in arterial stiffness with positional change and whether the stiffness changes are due to hydrostatic pressure alone or if physiological changes in vasoconstriction of the conduit arteries play a role in the modulation of arterial stiffness. Thirty participants' (male = 15, 24 ± 4 years) upper bodies were positioned at 0, 45, and 72° angles. Pulse wave velocity (PWV), cardio-ankle vascular index, carotid beta-stiffness index, carotid blood pressure (cBP), and carotid diameters were measured at each position. A gravitational height correction was determined using the vertical fluid column distance (mmHg) between the heart and carotid artery. Carotid beta-stiffness was calibrated using three methods: nonheight corrected cBP of each position, height corrected cBP of each position, and height corrected cBP of the supine position (theoretical model). Low frequency systolic blood pressure variability (LFSAP) was analyzed as a marker of sympathetic activity. PWV and cardio-ankle vascular index increased with position (P hydrostatic pressure. Arterial stiffness indices based on Method 2 were not different from Method 3 (P = 0.65). LFSAP increased in more upright positions (P pressure did not (P > 0.05). Arterial stiffness increases with a more upright body position. Carotid beta-stiffness needs to be calibrated accounting for hydrostatic effects of gravity if measured in a seated position. It is unclear why PWV increased as this increase was independent of blood pressure. No difference between Methods 2 and 3 presumably indicates that the beta-stiffness increases are only pressure dependent, despite the increase in vascular sympathetic modulation.

  19. Comparing the Effect of Continuous and Intermittent Irrigation Techniques on Complications of Arterial Catheter and Partial Thromboplastin Time in Patients Following Coronary Artery Bypass Grafting Surgery

    Directory of Open Access Journals (Sweden)

    Sedigheh Arta

    2017-04-01

    Full Text Available Background: Different approaches are available to irrigate the arterial catheter, such as continuous and intermittent techniques. However, there is a disagreement regarding the most appropriate method. Aim: this study aimed to compare the effect of two continuous and intermittent irrigation methods on complications of arterial catheter and partial thromboplastin time (PTT in patients with coronary artery bypass (CABG surgery. Method: This randomized clinical trial was conducted on 60 participants undergoing coronary artery bypass grafting surgery in open-heart surgery ICU at Imam Reza hospital in Mashhad, Iran, in 2016. In continuous group, the arterial catheter was continuously irrigated with heparin solution at the rate of 2cc/h, and in the intermittent group with a syringe containing 5cc heparin solution every 3 hours. In both groups, catheter was monitored and recorded every 3 hours (until 48 hours and 3 times from enrollment in terms of complications of partial thromboplastin time. Data were analyzed using SPSS version 16. Results: The findingsof independent t-test showed that the two groups are homogeneous in age (P =0.48. The result of Fisher's exact test revealed no significant difference between the two groups in terms of average incidence of complications during the first 24 hours (P=0.55 and second 24 hours (P=0.55 after catheterization. Also during the 48 hours after surgery, independent t-test results showed no statistically significant difference in partial thromboplastin time (P=0.53 between the two groups. Implications for Practice: According to the results of the research based on the lack of difference between continuous and intermittent irrigation methods up to 48 hours after catheter replacement in terms of arterial catheter complications, further long-term follow-up researches are recommended.

  20. Neck length and mean arterial pressure in the sauropod dinosaurs.

    Science.gov (United States)

    Hughes, Stephen; Barry, John; Russell, Jeremy; Bell, Robert; Gurung, Som

    2016-04-15

    How blood was able to reach the heads of the long-necked sauropod dinosaurs has long been a matter of debate and several hypotheses have been presented. For example, it has been proposed that sauropods had exceptionally large hearts, multiple 'normal' sized hearts spaced at regular intervals up the neck or held their necks horizontal, or that the siphon effect was in operation. By means of an experimental model, we demonstrate that the siphon principle is able to explain how blood was able to adequately perfuse the sauropod brain. The return venous circulation may have been protected from complete collapse by a structure akin to the vertebral venous plexus. We derive an equation relating neck height and mean arterial pressure, which indicates that with a mean arterial pressure similar to that of the giraffe, the maximum safe vertical distance between heart and head would have been about 12 m. A hypothesis is presented that the maximum neck length in the fossil record is due to the siphon height limit. The equation indicates that to migrate over high ground, sauropods would have had to either significantly increase their mean arterial pressure or keep their necks below a certain height dependent on altitude. © 2016. Published by The Company of Biologists Ltd.

  1. A pressão arterial está sendo medida? Is the blood pressure being measured?

    Directory of Open Access Journals (Sweden)

    Débora C. Alavarce

    2000-03-01

    Full Text Available A medida da pressão arterial faz parte do exame físico e deve ser realizada em toda consulta médica. Para avaliar se a pressão arterial é medida nas consultas médicas, foram consultados 500 prontuários de pacientes de primeira consulta ambulatorial, sendo 335 (67% provenientes de clínicas médicas e cirúrgicas e 165 (33% das clínicas ginecológica e obstétrica. A pressão arterial foi anotada em 39% das consultas realizadas (135±32/85±19 mm Hg, sendo que em 11% destas anotações a pressão diastólica estava acima de 90 mm Hg. Em relação ao diagnóstico prévio de hipertensão arterial verificou-se que: a em 62% dos prontuários não havia esta informação; b 20% referiram ter hipertensão, e em 79% destes a pressão arterial foi anotada; e c 18% referiram não ter hipertensão e 46% destes tiveram registro da pressão arterial. Portanto, a maior parte dos pacientes não teve sua pressão arterial anotada.The blood pressure measure is part of the physical exam and it should be accomplished in every medical consultation. To verify the blood pressure measured in the accomplished medical consultations record of first they were consulted it consults 500 patient's ambulatorial being 335 (67% coming of medical and surgical clinics and 165 (33% of the gynecological and obstetric clinics. The blood pressure was written down in 39% of the accomplished consultations (135+32 mm Hg 85+19 mm Hg, and 11% of this annotations the pressure diastólica was above 90 mm Hg. In relation to the previous diagnosis of hypertension it was verified that: a in 62% of the records there was not this information; b 20% referred to have hypertension, and in 79% of these the arterial pressure was scored; and c 18% referred not to have hypertension and 46% of these had registration of the arterial pressure. Therefore, most of the patients didn't have its logged arterial pressure.

  2. Classification of peripheral occlusive arterial diseases based on symptoms, signs and distal blood pressure measurements

    DEFF Research Database (Denmark)

    Tønnesen, K H; Noer, Ivan; Paaske, William

    1980-01-01

    Systolic blood pressures at toe and ankle were measured in 459 consecutive patients with occlusive arterial disease. Fifty-eight per cent had intermittent claudication with arterial disease of all degrees of severity. Seventeen per cent complained of rest pain having toe systolic pressures below 30...

  3. The impact of renal artery stent revascularization on blood pressure: 1-year follow-up of 110 cases

    International Nuclear Information System (INIS)

    Wang Chao; Zou Yinghua; Yang Min; Wang Jian; Tong Xiaoqiang; Song Li

    2007-01-01

    Objective: To investigate the effect of renal artery revascularization through renal artery stenting(PTRAS)on blood pressure in patients with renal artery stenosis. Methods: During April 2000 through May 2005 110 cases of renal artery stenosis received PTRAS and followed up for at least 1 year with blood pressure measurements pre-and 1 year post-PTRAS. Results: The technical success rate was 100% for all 110 cases. The renal artery stenosis were decreased from 60%-100% before PTRAS to 0%-15% after the stent placement. There was significant difference between blood pressure pre-and 1 year post PTRAS. Systolic pressures decreased from(153 ± 32) mmHg to(131 ± 27) mmHg and diastolic pressures from(87 ± 19) mmHg to(75 ± 19) mmHg. The administration of antihypertensive diugs reduced from(2.6 ± 0.9 ) sorts to(1.9 ± 0.9) sorts. Conclusions: PTRAS revascularization is an effective procedure for blood pressure control in renal vascular hypertension during one year follow up. (authors)

  4. CT and angiographic appearances of hepatocellular carcinoma partially fed by right inferior phrenic artery

    Energy Technology Data Exchange (ETDEWEB)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu [Tokyo Univ. (Japan). Faculty of Medicine

    1983-04-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially fed by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery.

  5. CT and angiographic appearances of hepatocellular carcinoma partially feeded by right inferior phrenic artery

    International Nuclear Information System (INIS)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu

    1983-01-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially feeded by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery. (author)

  6. Contribution of the Arterial System and the Heart to Blood Pressure during Normal Aging - A Simulation Study

    NARCIS (Netherlands)

    Maksuti, Elira; Westerhof, Nico; Westerhof, Berend E.; Broomé, Michael; Stergiopulos, Nikos

    2016-01-01

    During aging, systolic blood pressure continuously increases over time, whereas diastolic pressure first increases and then slightly decreases after middle age. These pressure changes are usually explained by changes of the arterial system alone (increase in arterial stiffness and vascular

  7. Combining central venous-to-arterial partial pressure of carbon dioxide difference and central venous oxygen saturation to guide resuscitation in septic shock.

    Science.gov (United States)

    Du, Wei; Liu, Da-Wei; Wang, Xiao-Ting; Long, Yun; Chai, Wen-Zhao; Zhou, Xiang; Rui, Xi

    2013-12-01

    Central venous oxygen saturation (Scvo2) is a useful therapeutic target when treating septic shock. We hypothesized that combining Scvo2 and central venous-to-arterial partial pressure of carbon dioxide difference (△Pco2) may provide additional information about survival. We performed a retrospective analysis of 172 patients treated for septic shock. All patients were treated using goal-directed therapy to achieve Scvo2 ≥ 70%. After 6 hours of treatment, we divided patients into 4 groups based on Scvo2 (<70% or ≥ 70%) and △Pco2 (<6 mm Hg or ≥ 6 mm Hg). Overall, 28-day mortality was 35.5%. For patients in whom the Scvo2 target was not achieved at 6 hours, mortality was 50.0%, compared with 29.5% in those in whom Scvo2 exceeded 70% (P = .009). In patients with Scvo2 ≥ 70%, mortality was lower if △Pco2 was <6 mm Hg than if △Pco2 was ≥ 6 mm Hg (56.1% vs 16.1%, respectively; P < .001) and 6-hour lactate clearance was superior (0.01 ± 0.61 vs 0.21 ± 0.31, respectively; P = .016). The combination of Scvo2 and △Pco2 appears to predict outcome in critically ill patients resuscitated from septic shock better than Scvo2 alone. Patients who meet both targets appear to clear lactate more efficiently. © 2013.

  8. Circadian rhythm of arterial blood pressure and albuminuria in diabetic nephropathy

    DEFF Research Database (Denmark)

    Hansen, H P; Rossing, P; Tarnow, L

    1996-01-01

    The aim of our study was to evaluate the diurnal relationship between arterial blood pressure and albuminuria, and some potential mechanisms responsible for impaired nocturnal blood pressure reduction (non-dippers, groups I and II) in diabetic nephropathy (DN). Twenty-four-hour ambulatory blood p...

  9. Prognostic value of renal fractional flow reserve in blood pressure response after renal artery stenting (PREFER study).

    Science.gov (United States)

    Kądziela, Jacek; Januszewicz, Andrzej; Prejbisz, Aleksander; Michałowska, Ilona; Januszewicz, Magdalena; Florczak, Elżbieta; Kalińczuk, Łukasz; Norwa-Otto, Bożena; Warchoł, Ewa; Witkowski, Adam

    2013-01-01

    The aim of our study was to determine a potential relationship between resting translesional pressures ratio (Pd/Pa ratio), renal fractional flow reserve (rFFR) and blood pressure response after renal artery stenting. Thirty five hypertensive patients (49% males, mean age 64 years) with at least 60% stenosis in angiography, underwent renal artery stenting. Translesional systolic pressure gradient (TSPG), Pd/Pa ratio (the ratio of mean distal to lesion and mean proximal pressures) and hyperemic rFFR - after intrarenal administration of papaverine - were measured before stent implantation. Ambulatory blood pressure measurements (ABPM) were recorded before the procedure and after 6 months. The ABPM results were presented as blood pressure changes in subgroups of patients with normal (≥ 0.9) vs. abnormal (renal artery stenting. Median changes of 24-h systolic/diastolic blood pressure were comparable in patients with abnormal vs. normal Pd/Pa ratio (-4/-3 vs. 0/2 mm Hg; p = NS) and with abnormal vs. normal rFFR (-2/-1 vs. -2/-0.5 mm Hg, respectively). Physiological assessment of renal artery stenosis using Pd/Pa ratio and papaverine- induced renal fractional fl ow reserve did not predict hypertension response after renal artery stenting.

  10. Correlation Between Doppler Echocardiography and Right Heart Catheterization Derived Pulmonary Artery Pressures: Impact of Right Atrial Pressures

    International Nuclear Information System (INIS)

    Ahmed, I.; Nuri, M. M. H.; Zakariyya, A. N.; Ahmad, S. M.; Ahmed, M.

    2016-01-01

    Objective: To evaluate the correlation between Doppler echocardiography (DE) and right heart catheterization (RHC) derived pulmonary artery pressures and to assess the impact of right atrial (RA) pressures on this correlation. Study Design: Cross-sectional analytical study. Place and Duration of Study: Cardiology Department, Tahir Heart Institute, Chenab Nagar, from June 2013 to December 2014. Methodology: All patients undergoing RHC were included. Relevant data were collected from hospital database. Continuous variables were expressed as the mean and SD or as the median and interquartile range where the distributions were skewed. Pearson correlation coefficient and Bland-Altman method were used to correlate DE derived right ventricular systolic pressure (RVSP) and RHC derived systolic pulmonary artery pressures (sPAP). Adjusted RVSP was calculated by replacing default value of RA pressure (10 mmHg) with RHC derived mean RA pressure. Receiver operating characteristic curve (ROC) was used to identify the best cut-off value of RVSP in predicting pulmonary hypertension. Results: Fifty-one patients completed the study protocol. Mean age of study population was 45.22 ± 15.25 years with male to female ratio of 1.47:1. Median error was 13 mmHg (7 to 20). Pearson correlation coefficient (r) between RVSP and sPAP was 0.72. Bland-Altman method of correlation showed bias of +4.43 mmHg with 95% limits of agreement ranging from -34.61 to +43.47. Using ROC curve, the best cut-off value of RVSP was greater than 52 mmHg with accuracy of 75% (sensitivity: 81%, specificity: 69%) in predicting pulmonary hypertension. Adjusted RVSP showed only little improvement in correlation (r = 0.75), adjusted error (13.65 ± 13.05) and diagnostic accuracy (79%). Conclusion: Doppler echocardiography can frequently overestimate pulmonary artery pressures. Though correctly estimated RA pressure may improve this correlation, yet its contribution is only minimal. (author)

  11. Diastolic coronary artery pressure-flow velocity relationships in conscious man.

    Science.gov (United States)

    Dole, W P; Richards, K L; Hartley, C J; Alexander, G M; Campbell, A B; Bishop, V S

    1984-09-01

    We characterised the diastolic pressure-flow velocity relationship in the normal left coronary artery of conscious man before and after vasodilatation with angiographic contrast medium. Phasic coronary artery pressure and flow velocity were measured in ten patients during individual diastoles (0.5 to 1.0 s) using a 20 MHz catheter-tipped, pulsed Doppler transducer. All pressure-flow velocity curves were linear over the diastolic pressure range of 110 +/- 15 (SD) mmHg to 71 +/- 7 mmHg (r = 0.97 +/- 0.01). In the basal state, values for slope and extrapolated zero flow pressure intercept averaged 0.35 +/- 0.12 cm X s-1 X mmHg-1 and 51.7 +/- 8.6 mmHg, respectively. Vasodilatation resulted in a 2.5 +/- 0.5 fold increase in mean flow velocity. The diastolic pressure-flow velocity relationship obtained during peak vasodilatation compared to that during basal conditions was characterised by a steeper slope (0.80 +/- 0.48 cm X s-1 X mmHg-1, p less than 0.001) and lower extrapolated zero flow pressure intercept (37.9 +/- 9.8 mmHg, p less than 0.05). Mean right atrial pressure for the group averaged 4.4 +/- 1.7 mmHg, while left ventricular end-diastolic pressure averaged 8.7 +/- 2.8 mmHg. These observations in man are similar to data reported in the canine coronary circulation which are consistent with a vascular waterfall model of diastolic flow regulation. In this model, coronary blood flow may be regulated by changes in diastolic zero flow pressure as well as in coronary resistance.

  12. PX-18 Protects Human Saphenous Vein Endothelial Cells under Arterial Blood Pressure.

    Science.gov (United States)

    Kupreishvili, Koba; Stooker, Wim; Emmens, Reindert W; Vonk, Alexander B A; Sipkens, Jessica A; van Dijk, Annemieke; Eijsman, Leon; Quax, Paul H; van Hinsbergh, Victor W M; Krijnen, Paul A J; Niessen, Hans W M

    2017-07-01

    Arterial blood pressure-induced shear stress causes endothelial cell apoptosis and inflammation in vein grafts after coronary artery bypass grafting. As the inflammatory protein type IIA secretory phospholipase A 2 (sPLA 2 -IIA) has been shown to progress atherosclerosis, we hypothesized a role for sPLA 2 -IIA herein. The effects of PX-18, an inhibitor of both sPLA 2 -IIA and apoptosis, on residual endothelium and the presence of sPLA 2 -IIA were studied in human saphenous vein segments (n = 6) perfused at arterial blood pressure with autologous blood for 6 hrs. The presence of PX-18 in the perfusion blood induced a significant 20% reduction in endothelial cell loss compared to veins perfused without PX18, coinciding with significantly reduced sPLA 2 -IIA levels in the media of the vein graft wall. In addition, PX-18 significantly attenuated caspase-3 activation in human umbilical vein endothelial cells subjected to shear stress via mechanical stretch independent of sPLA 2 -IIA. In conclusion, PX-18 protects saphenous vein endothelial cells from arterial blood pressure-induced death, possibly also independent of sPLA 2 -IIA inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Randomized trial of low versus high carbon dioxide insufflation pressures in posterior retroperitoneoscopic adrenalectomy.

    Science.gov (United States)

    Fraser, Sheila; Norlén, Olov; Bender, Kyle; Davidson, Joanne; Bajenov, Sonya; Fahey, David; Li, Shawn; Sidhu, Stan; Sywak, Mark

    2018-05-01

    Posterior retroperitoneoscopic adrenalectomy has gained widespread acceptance for the removal of benign adrenal tumors. Higher insufflation pressures using carbon dioxide (CO 2 ) are required, although the ideal starting pressure is unclear. This prospective, randomized, single-blinded, study aims to compare physiologic differences with 2 different CO 2 insufflation pressures during posterior retroperitoneoscopic adrenalectomy. Participants were randomly assigned to a starting insufflation pressure of 20 mm Hg (low pressure) or 25 mm Hg (high pressure). The primary outcome measure was partial pressure of arterial CO 2 at 60 minutes. Secondary outcomes included end-tidal CO 2 , arterial pH, blood pressure, and peak airway pressure. Breaches of protocol to change insufflation pressure were permitted if required and were recorded. A prospective randomized trial including 31 patients (low pressure: n = 16; high pressure: n = 15) was undertaken. At 60 minutes, the high pressure group had greater mean partial pressure of arterial CO 2 (64 vs 50 mm Hg, P = .003) and end-tidal CO 2 (54 vs 45 mm Hg, P = .008) and a lesser pH (7.21 vs 7.29, P = .0005). There were no significant differences in base excess, peak airway pressure, operative time, or duration of hospital stay. Clinically indicated protocol breaches were more common in the low pressure than the high pressure group (8 vs 3, P = .03). In posterior retroperitoneoscopic adrenalectomy, greater insufflation pressures are associated with greater partial pressure of arterial CO 2 and end-tidal CO 2 and lesser pH at 60 minutes, be significant. Commencing with lesser CO 2 insufflation pressures decreases intraoperative acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. psychrometry: from partial pressures to mole fractions

    African Journals Online (AJOL)

    ES Obe

    1980-03-01

    Mar 1, 1980 ... as an ideal gas mixture. Partial pressures then become identical: to mole fractions and sets of psychometric parameters result from rather elementary thermodynamic relations. Search for more accurate data has long led to the realization that neither dry air nor pure water vapour behaves like an ideal gas,.

  15. Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.

    Science.gov (United States)

    Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe

    2017-07-01

    After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.

  16. Elevated plasma endothelin-1 and pulmonary arterial pressure in children exposed to air pollution.

    Science.gov (United States)

    Calderón-Garcidueñas, Lilian; Vincent, Renaud; Mora-Tiscareño, Antonieta; Franco-Lira, Maricela; Henríquez-Roldán, Carlos; Barragán-Mejía, Gerardo; Garrido-García, Luis; Camacho-Reyes, Laura; Valencia-Salazar, Gildardo; Paredes, Rogelio; Romero, Lina; Osnaya, Hector; Villarreal-Calderón, Rafael; Torres-Jardón, Ricardo; Hazucha, Milan J; Reed, William

    2007-08-01

    Controlled exposures of animals and humans to particulate matter (PM) or ozone air pollution cause an increase in plasma levels of endothelin-1, a potent vasoconstrictor that regulates pulmonary arterial pressure. The primary objective of this field study was to determine whether Mexico City children, who are chronically exposed to levels of PM and O(3) that exceed the United States air quality standards, have elevated plasma endothelin-1 levels and pulmonary arterial pressures. We conducted a study of 81 children, 7.9 +/- 1.3 years of age, lifelong residents of either northeast (n = 19) or southwest (n = 40) Mexico City or Polotitlán (n = 22), a control city with PM and O(3) levels below the U.S. air quality standards. Clinical histories, physical examinations, and complete blood counts were done. Plasma endothelin-1 concentrations were determined by immunoassay, and pulmonary arterial pressures were measured by Doppler echocardiography. Mexico City children had higher plasma endothelin-1 concentrations compared with controls (p < 0.001). Mean pulmonary arterial pressure was elevated in children from both northeast (p < 0.001) and southwest (p < 0.05) Mexico City compared with controls. Endothelin-1 levels in Mexico City children were positively correlated with daily outdoor hours (p = 0.012), and 7-day cumulative levels of PM air pollution < 2.5 mum in aerodynamic diameter (PM(2.5)) before endothelin-1 measurement (p = 0.03). Chronic exposure of children to PM(2.5) is associated with increased levels of circulating endothelin-1 and elevated mean pulmonary arterial pressure.

  17. Elevated Plasma Endothelin-1 and Pulmonary Arterial Pressure in Children Exposed to Air Pollution

    Science.gov (United States)

    Calderón-Garcidueñas, Lilian; Vincent, Renaud; Mora-Tiscareño, Antonieta; Franco-Lira, Maricela; Henríquez-Roldán, Carlos; Barragán-Mejía, Gerardo; Garrido-García, Luis; Camacho-Reyes, Laura; Valencia-Salazar, Gildardo; Paredes, Rogelio; Romero, Lina; Osnaya, Hector; Villarreal-Calderón, Rafael; Torres-Jardón, Ricardo; Hazucha, Milan J.; Reed, William

    2007-01-01

    Background Controlled exposures of animals and humans to particulate matter (PM) or ozone air pollution cause an increase in plasma levels of endothelin-1, a potent vasoconstrictor that regulates pulmonary arterial pressure. Objectives The primary objective of this field study was to determine whether Mexico City children, who are chronically exposed to levels of PM and O3 that exceed the United States air quality standards, have elevated plasma endothelin-1 levels and pulmonary arterial pressures. Methods We conducted a study of 81 children, 7.9 ± 1.3 years of age, lifelong residents of either northeast (n = 19) or southwest (n = 40) Mexico City or Polotitlán (n = 22), a control city with PM and O3 levels below the U.S. air quality standards. Clinical histories, physical examinations, and complete blood counts were done. Plasma endothelin-1 concentrations were determined by immunoassay, and pulmonary arterial pressures were measured by Doppler echocardiography. Results Mexico City children had higher plasma endothelin-1 concentrations compared with controls (p < 0.001). Mean pulmonary arterial pressure was elevated in children from both northeast (p < 0.001) and southwest (p < 0.05) Mexico City compared with controls. Endothelin-1 levels in Mexico City children were positively correlated with daily outdoor hours (p = 0.012), and 7-day cumulative levels of PM air pollution < 2.5 μm in aerodynamic diameter (PM2.5) before endothelin-1 measurement (p = 0.03). Conclusions Chronic exposure of children to PM2.5 is associated with increased levels of circulating endothelin-1 and elevated mean pulmonary arterial pressure. PMID:17687455

  18. End-inspiratory rebreathing reduces the end-tidal to arterial PCO2 gradient in mechanically ventilated pigs

    NARCIS (Netherlands)

    Fierstra, Jorn; Machina, Matthew; Battisti-Charbonney, Anne; Duffin, James; Fisher, Joseph Arnold; Minkovich, Leonid

    Noninvasive monitoring of the arterial partial pressures of CO2 (PaCO2) of critically ill patients by measuring their end-tidal partial pressures of CO2 (PetCO(2)) would be of great clinical value. However, the gradient between PetCO(2) and PaCO2 (Pet-aCO(2)) in such patients typically varies over a

  19. Effect of Electroacupuncture on Transcutaneous Oxygen Partial Pressure During Hyperbaric Oxygen Therapy in Healthy Individuals.

    Science.gov (United States)

    Qu, Lan; Ye, Yong; Li, Chunfeng; Gao, Guangkai

    2015-01-01

    The goal of hyperbaric oxygen therapy (HBOT) is to increase the oxygen (O₂) supply to the body significantly. Because of the toxic side effects and complications of hyperbaric oxygen (HBO₂), the environmental pressure and treatment time must be restricted. The research team hypothesized that other therapies administered during HBOT could safely improve the value of the arterial oxygen partial pressure (PaO₂) during HBOT and improve its therapeutic effect. The study intended to investigate whether electroacupuncture (EA) while receiving HBOT had a greater effect for healthy individuals than HBOT or EA alone or EA combined with normobaric pure oxygen (pure O₂). The research team designed a randomized, controlled trial. The study was performed in the Department of Hyperbaric Medicine at the No. 401 Hospital of the People's Liberation Army in Qingdao, China. A total of 81 volunteers were recruited. After thorough physical examination and laboratory testing, 21 volunteers were excluded from the study. Participants included 60 healthy volunteers. Participants were randomly assigned to 1 of 4 groups of 15 participants each: (1) an HBOT group, (2) an EA group, (3) an EA During HBOT group, and (4) an EA Combined With Pure O₂group. Because at the current technology level a blood gas analyzer cannot test PaO₂during HBOT, transcutaneous oxygen partial pressure (PtcO₂) of the participants was tested instead. Before, during, and after EA, variations in PtcO₂were monitored in each group. For the EA During HBOT group, (1) the increase in PtcO₂during EA was significantly greater than that observed for the other 3 groups (P > .05). The EA During HBOT method provided improvements in the efficacy, safety, and tolerability of HBOT, and the study's results partially demonstrated the accuracy of the research team's hypothesis that EA therapy applied during HBOT could safely improve the value of PtcO₂(PaO₂) during HBOT and produce a greater therapeutic effect.

  20. A theoretical description of arterial pressure-flow relationships with verification in the isolated hindlimb of the dog.

    Science.gov (United States)

    Jackman, A P; Green, J F

    1990-01-01

    We developed and tested a new two-compartment serial model of the arterial vasculature which unifies the capacitance (downstream arterial compliance) and waterfall (constant downstream pressure load) theories of blood flow through the arteries. In this model, blood drains from an upstream compliance through a resistance into a downstream compliance which empties into the veins through a downstream resistance which terminates in a constant pressure load. Using transient arterial pressure data obtained from an isolated canine hindlimb preparation, we tested this model, using a stop-flow technique. Numerical parameter estimation techniques were used to estimate the physiologic parameters of the model. The downstream compliance was found to be more than ten times larger than the upstream compliance and the constant pressure load was significantly above venous pressures but decreased in response to vasodilation. Our results support the applicability of both the capacitance and waterfall theories.

  1. Effect of Citrus paradisi extract and juice on arterial pressure both in vitro and in vivo.

    Science.gov (United States)

    Díaz-Juárez, J A; Tenorio-López, F A; Zarco-Olvera, G; Valle-Mondragón, L Del; Torres-Narváez, J C; Pastelín-Hernández, G

    2009-07-01

    Citrus paradisi (grapefruit) consumption is considered as beneficial and it is popularly used for the treatment of a vast array of diseases, including hypertension. In the present study, the coronary vasodilator and hypotensive effects of Citrus paradisi peel extract were assessed in the Langendorff isolated and perfused heart model and in the heart and lung dog preparation. In both models, Citrus paradisi peel extract decreased coronary vascular resistance and mean arterial pressure when compared with control values (60 +/- 15 x 10(7) dyn s cm(-5) vs 100 +/- 10 x 10(7) dyn s cm(-5) and 90 mmHg vs 130 +/- 15 mmHg, respectively). These decreases in coronary vascular resistance and mean arterial pressure were blocked when isolated and perfused hearts and mongrel dogs were pre-treated with L-NAME. In humans, Citrus paradisi juice decreased diastolic arterial pressure and systolic arterial pressure both in normotensive and hypertensive subjects. Citrus paradisi juice produced a greater decrease in mean arterial pressure when compared with Citrus sinensis juice, cow milk and a vitamin C-supplemented beverage. However, more detailed studies are required to isolate, purify and evaluate the chemical compounds responsible for this pharmacological effect and to clarify its possible role for treating hypertension. Copyright 2009 John Wiley & Sons, Ltd.

  2. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  3. Pulmonary artery pressure increases during commercial air travel in healthy passengers.

    Science.gov (United States)

    Smith, Thomas G; Talbot, Nick P; Chang, Rae W; Wilkinson, Elizabeth; Nickol, Annabel H; Newman, David G; Robbins, Peter A; Dorrington, Keith L

    2012-07-01

    It is not known whether the mild hypoxia experienced by passengers during commercial air travel triggers hypoxic pulmonary vasoconstriction and increases pulmonary artery pressure in flight. Insidious pulmonary hypertensive responses could endanger susceptible passengers who have cardiopulmonary disease or increased hypoxic pulmonary vascular sensitivity. Understanding these effects may improve pre-flight assessment of fitness-to-fly and reduce in-flight morbidity and mortality. Eight healthy volunteers were studied during a scheduled commercial airline flight from London, UK, to Denver, CO. The aircraft was a Boeing 777 and the duration of the flight was 9 h. Systolic pulmonary artery pressure (sPAP) was assessed by portable Doppler echocardiography during the flight and over the following week in Denver, where the altitude (5280 ft/1610 m) simulates a commercial airliner environment. Cruising cabin altitude ranged between 5840 and 7170 ft (1780 to 2185 m), and mean arterial oxygen saturation was 95 +/- 0.6% during the flight. Mean sPAP increased significantly in flight by 6 +/- 1 mmHg to 33 +/- 1 mmHg, an increase of approximately 20%. After landing in Denver, sPAP was still 3 +/- 1 mmHg higher than baseline and remained elevated at 30 +/- 1 mmHg for a further 12 h. Pulmonary artery pressure increases during commercial air travel in healthy passengers, raising the possibility that hypoxic pulmonary hypertension could develop in susceptible individuals. A hypoxia altitude simulation test with simultaneous echocardiography ('HAST-echo') may be beneficial in assessing fitness to fly in vulnerable patients.

  4. Integration of a capacitive pressure sensing system into the outer catheter wall for coronary artery FFR measurements

    Science.gov (United States)

    Stam, Frank; Kuisma, Heikki; Gao, Feng; Saarilahti, Jaakko; Gomes Martins, David; Kärkkäinen, Anu; Marrinan, Brendan; Pintal, Sebastian

    2017-05-01

    The deadliest disease in the world is coronary artery disease (CAD), which is related to a narrowing (stenosis) of blood vessels due to fatty deposits, plaque, on the arterial walls. The level of stenosis in the coronary arteries can be assessed by Fractional Flow Reserve (FFR) measurements. This involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. The blood flow is represented by a pressure drop, thus a pressure wire or pressure sensor integrated in a catheter can be used to calculate the ratio between the coronary pressure distal to the stenosis and the normal coronary pressure. A 2 Fr (0.67mm) outer diameter catheter was used, which required a high level of microelectronics miniaturisation to fit a pressure sensing system into the outer wall. The catheter has an eccentric guidewire lumen with a diameter of 0.43mm, which implies that the thickest catheter wall section provides less than 210 microns height for flex assembly integration consisting of two dies, a capacitive MEMS pressure sensor and an ASIC. In order to achieve this a very thin circuit flex was used, and the two chips were thinned down to 75 microns and flip chip mounted face down on the flex. Many challenges were involved in obtaining a flex layout that could wrap into a small tube without getting the dies damaged, while still maintaining enough flexibility for the catheter to navigate the arterial system.

  5. Partial pressures of oxygen, phosphorus and fluorine in some lunar lavas

    Science.gov (United States)

    Nash, W. P.; Hausel, W. D.

    1973-01-01

    Lunar sample 14310 is a feldspar-rich basalt which shows no evidence of shock deformation or recrystallization. Pyroxenes include Mg-rich orthopyroxene, pigeonite and augite; pyroxferroite occurs in the interstitial residuum. Plagioclase feldspars are zoned from An(96) to An(67), and variations in feldspar compositions do not necessarily indicate loss of Na during eruption of the lava. Opaque phases include ilmenite, ulvospinel, metallic iron, troilite, and schreibersite. Both whitlockite and apatite are present, and the interstitial residua contain baddeleyite, tranquillityite and barium-rich sanidine. Theoretical calculations provide estimates of partial pressures of oxygen, phosphorus, and fluorine in lunar magmas. In general, partial pressures of oxygen are restricted by the limiting assemblages of iron-wuestite and ilmenite-iron-rutile; phosphorus partial pressures are higher in lunar magmas than in terrestrial lavas. The occurrence of whitlockite indicates significantly lower fugacities of fluorine in lunar magmas than in terrestrial magmas.

  6. Arterial compliance in patients with cirrhosis: stroke volume-pulse pressure ratio as simplified index

    DEFF Research Database (Denmark)

    Fuglsang, S; Bendtsen, F; Christensen, E

    2001-01-01

    Arterial function may be altered in patients with cirrhosis. We determined compliance of the arterial tree (C(1)) in relation to systemic and splanchnic hemodynamic derangement and clinical variables. C(1) and the stroke volume-pulse pressure index (SV/PP) were significantly higher (+62% and +40%...... predictors of SV/PP (P abnormalities in the arterial compliance of these patients....

  7. A Pulse Wave Velocity Based Method to Assess the Mean Arterial Blood Pressure Limits of Autoregulation in Peripheral Arteries

    Directory of Open Access Journals (Sweden)

    Ananya Tripathi

    2017-11-01

    Full Text Available Background: Constant blood flow despite changes in blood pressure, a phenomenon called autoregulation, has been demonstrated for various organ systems. We hypothesized that by changing hydrostatic pressures in peripheral arteries, we can establish these limits of autoregulation in peripheral arteries based on local pulse wave velocity (PWV.Methods: Electrocardiogram and plethysmograph waveforms were recorded at the left and right index fingers in 18 healthy volunteers. Each subject changed their left arm position, keeping the right arm stationary. Pulse arrival times (PAT at both fingers were measured and used to calculate PWV. We calculated ΔPAT (ΔPWV, the differences between the left and right PATs (PWVs, and compared them to the respective calculated blood pressure at the left index fingertip to derive the limits of autoregulation.Results: ΔPAT decreased and ΔPWV increased exponentially at low blood pressures in the fingertip up to a blood pressure of 70 mmHg, after which changes in ΔPAT and ΔPWV were minimal. The empirically chosen 20 mmHg window (75–95 mmHg was confirmed to be within the autoregulatory limit (slope = 0.097, p = 0.56. ΔPAT and ΔPWV within a 20 mmHg moving window were not significantly different from the respective data points within the control 75–95 mmHg window when the pressure at the fingertip was between 56 and 110 mmHg for ΔPAT and between 57 and 112 mmHg for ΔPWV.Conclusions: Changes in hydrostatic pressure due to changes in arm position significantly affect peripheral arterial stiffness as assessed by ΔPAT and ΔPWV, allowing us to estimate peripheral autoregulation limits based on PWV.

  8. Noninvasive estimation of pulmonary arterial pressure by analysis of pulmonary blood-flow distribution

    International Nuclear Information System (INIS)

    Konstam, M.A.; Strauss, H.W.; Alpert, N.M.; Miller, S.W.; Murphy, R.X.; Greene, R.E.; McKusick, K.A.

    1979-01-01

    To determine whether a correlation exists between pulmonary arterial (PA) pressure (P/sub a/) and the distribution of pulmonary blood flow, this distribution was measured in four upright dogs in the control state and during intravenous infusions of epinephrine or prostaglandin F/sub 2α/. During suspension of respiration, 15 mCi of Xe-133 were injected intravenously, and perfusion and equilibration lung images were recorded with a scintillation camera. The procedure was performed several times on each dog, with and without pharmacological elevation of PA pressure by 5 to 50 cm H 2 O. For each scintigram, the relative blood flow per unit ventilated lung volume (F) was plotted against centimeters above the hilum (h). Pulmonary arterial pressure was derived from each curve, assuming the relation F = B(P/sub a/ - hD) 2 , where B = constant and D = specific gravity of blood. Calculated PA pressure correlated strongly (r = 0.83) with measured PA pressure, suggesting a possible means of noninvasive estimation of PA pressure

  9. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery

    International Nuclear Information System (INIS)

    Chin, K Y; Panerai, R B

    2013-01-01

    Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measurements closer to the ascending aorta, a new device was constructed to measure ABP in the superficial temporal artery (STA) using photoplethysmography and the arterial volume clamping technique. The optoelectronic circuitry to generate the photoplethysmogram is contained in a specially designed probe placed over the STA and kept in place with a head frame. The prototype (STAbp) also includes original designs for the pneumatic, electronic, signal processing, control and display sub-systems. A self-calibration feature regularly updates the photoplethysmogram operating point to improve accuracy. The performance of the STAbp was compared against the Finapres in 19 healthy subjects. At rest, the bias (SD d ) was −23.1 (15.05), −10.8 (13.83) and −12.4 (12.93) mmHg for systolic, mean and diastolic pressures respectively, without significant differences in drift between the two devices. The 99% bandwidth (SD) for the spectral distribution of ABP waveforms was 5.3 (1.46) Hz for STAbp and 6.8 (0.73) Hz for the Finapres (p < 0.01). Handgrip manoeuvre showed a very similar response to the Finapres, including the rapid return to baseline on release. The new STAbp device has considerable potential as a new tool for clinical and research applications where continuous recording of more central ABP is advantageous compared to peripheral alternatives. (paper)

  10. Oxidative stress mediated arterial dysfunction in patients with obstructive sleep apnoea and the effect of continuous positive airway pressure treatment

    Directory of Open Access Journals (Sweden)

    Del Ben Maria

    2012-07-01

    Full Text Available Abstract Background Several studies suggest an increase of oxidative stress and a reduction of endothelial function in obstructive sleep apnoea syndrome (OSAS. We assessed the association between OSAS, endothelial dysfunction and oxidative stress. Further aim was to evaluate the effect of nasal continuous positive airway pressure (nCPAP on oxidative stress and arterial dysfunction. Methods We studied 138 consecutive patients with heavy snoring and possible OSAS. Patients underwent unattended overnight home polysomnography. Ten patients with severe OSAS were revaluated after 6 months of nCPAP therapy. To assess oxidative stress in vivo, we measured urinary 8-iso-PGF2α and serum levels of soluble NOX2-derived peptide (sNOX2-dp. Serum levels of nitrite/nitrate (NOx were also determined. Flow-mediated brachial artery dilation (FMD was measured to asses endothelial function. Results Patients with severe OSAS had higher urinary 8-iso-PGF2α (p Conclusions The results of our study indicate that patients with OSAS and cardiometabolic comorbidities have increased oxidative stress and arterial dysfunction that are partially reversed by nCPAP treatment.

  11. Location of the internal carotid artery and ophthalmic artery segments for non-invasive intracranial pressure measurement by multi-depth TCD.

    Science.gov (United States)

    Hamarat, Yasin; Deimantavicius, Mantas; Kalvaitis, Evaldas; Siaudvytyte, Lina; Januleviciene, Ingrida; Zakelis, Rolandas; Bartusis, Laimonas

    2017-12-01

    The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler.

  12. Design and control of the oxygen partial pressure of UO2 in TGA using the humidification system

    International Nuclear Information System (INIS)

    Lee, S.; Knight, T.W.; Roberts, E.

    2015-01-01

    Highlights: • We focus on measurement of oxygen partial pressure and change of O/M ratio under specific conditions produced by the humidification system. • This shows that the humidification system is stable, accurate, and reliable enough to be used for experiments of the oxygen partial pressure measurement for the oxide fuels. • The humidification system has benefits of easy control and flexibility for producing various oxygen partial pressures with fixed hydrogen gas flow rate. - Abstract: The oxygen to uranium (O/U) ratio of UO 2±x is determined by the oxygen content of the sample and is affected by oxygen partial pressure (pO 2 ) of the surrounding gas. Oxygen partial pressure is controllable by several methods. A common method to produce different oxygen partial pressures is the use of equilibria of different reaction gases. There are two common methods: H 2 O/H 2 reaction and CO 2 /CO reaction. In this work, H 2 O/H 2 reaction using a humidifier was employed and investigated to ensure that this humidification system for oxygen partial pressure is stable and accurate for use in Thermogravimetric Analyzer (TGA) experiments with UO 2 . This approach has the further advantage of flexibility to make a wide range of oxygen partial pressure with fixed hydrogen gas flow rate only by varying temperature of water in the humidifier. The whole system for experiments was constructed and includes the humidification system, TGA, oxygen analyzer, and gas flow controller. Uranium dioxide (UO 2 ) samples were used for experiments and oxygen partial pressure was measured at the equilibrium state of stoichiometric UO 2.0 . Oxygen partial pressures produced by humidification (wet gas) system were compared to the approach using mixed dry gases (without humidification system) to demonstrate that the humidification system provides for more stable and accurate oxygen partial pressure control. This work provides the design, method, and analysis of a humidification system for

  13. [The predictive value of dynamic arterial elastance in arterial pressure response after norepinephrine dosage reduction in patients with septic shock].

    Science.gov (United States)

    Liang, F M; Yang, T; Dong, L; Hui, J J; Yan, J

    2017-05-01

    Objective: To assess whether dynamic arterial elastance(Ea(dyn))can be used to predict the reduction of arterial pressure after decreasing norepinephrine (NE) dosage in patients with septic shock. Methods: A prospective observational cohort study was conducted. Thirty-two patients with septic shock and mechanical ventilationwere enrolledfrom January 2014 to December 2015 in ICU of Wuxi People's Hospital of Nanjing Medical University. Hemodynamic parameters were recorded by pulse contour cardiac output(PiCCO)monitoring technology before and after decreasing norepinephrine dosage. Ea(dyn) was defined as the ratio of pulse pressure variation (PPV) to stroke volume variation (SVV). Mean arterial pressure(MAP) variation was calculated after decreasing the dose of NE. Response was defined as a ≥15% decrease of MAP. AUC was plotted to assess the value of Ea(dyn) in predicting MAP response. Results: A total of 32 patients were enrolled in our study, with 13 responding to NE dose decrease where as the other 19 did not. Ea(dyn) was lower in responders than in nonresponders (0.77±0.13 vs 1.09±0.31, P blood pressure variation, diastolic blood pressure variation, systemic vascular resistance variation and MAP variation( r =0.621, P =0.000; r =0.735, P =0.000; r =0.756, P =0.000; r =0.568, P =0.000 respectively). However, stoke volume variation, baseline level of systemic vascular resistance and NE baseline dose were not correlated with Ea(dyn) baseline value( r =0.264, P =0.076; r =0.078, P =0.545; r =0.002, P =0.987 respectively). Ea(dyn)≤0.97 predicted a decrease of MAP when decreasing NE dose, with an area under the receiver-operating characteristic curve of 0.85.The sensitivity was 100.0% and specificity was 73.7%. Conclusions: In septic shock patients treated with NE, Ea(dyn) is an index to predict the decrease of arterial pressure in response to NE dose reduction.

  14. Acidogenesis driven by hydrogen partial pressure towards bioethanol production through fatty acids reduction

    International Nuclear Information System (INIS)

    Sarkar, Omprakash; Butti, Sai Kishore; Venkata Mohan, S.

    2017-01-01

    H 2 partial pressure drives the reduction of carboxylic acid (short chain fatty acids) formed as primary metabolites in acidogenic fermentation to form bioalcohols. Microbial catalysis under the influence of H 2 partial pressure was evaluated in comparison with a reactor operated at atmospheric pressure under identical conditions. Carboxylic acid reduction gets regulated selectively by the influence of elevated pressures and redox conditions, resulting in the formation of alcohols. The non-equilibrium of the intra and extracellular H 2 ions causes the anaerobic bacteria to alter their pathways as a function of interspecies H 2 transfer. Ethanol production was quantified, as acetic acid was the major carboxylic acid synthesised during acidogenesis. H 2 pressure influenced the electrochemical activity which was reflected in the distinct variation of the electron transfer rates and the catalytic activity of redox mediators (NAD + /NADH, flavoproteins and iron-sulphur clusters). The bioprocess depicted in this communication depicted a non-genetic regulation of product formation, understanding the acidogenic metabolism and alternate route for alcohol production. - Highlights: • H 2 partial pressure in HPR aided in the reduction of carboxylic acids to alcohols. • Production and consumption rate of VFAs were correlating with alcohol formation. • Metabolic shift was evident with bioelectrochical analysis. • NADH/NAD + ratio and H 2 partial pressure coupled in enhanced solventogenesis.

  15. Calibration Of Partial-Pressure-Of-Oxygen Sensors

    Science.gov (United States)

    Yount, David W.; Heronimus, Kevin

    1995-01-01

    Report and analysis of, and discussion of improvements in, procedure for calibrating partial-pressure-of-oxygen sensors to satisfy Spacelab calibration requirements released. Sensors exhibit fast drift, which results in short calibration period not suitable for Spacelab. By assessing complete process of determining total drift range available, calibration procedure modified to eliminate errors and still satisfy requirements without compromising integrity of system.

  16. Elevated arterial blood pressure after superior cavo-pulmonary anastomosis is associated with elevated pulmonary artery pressure and cerebrovascular dysautoregulation.

    Science.gov (United States)

    Cabrera, Antonio G; Kibler, Kathleen K; Blaine Easley, R; Goldsworthy, Michelle; Shekerdemian, Lara S; Andropoulos, Dean B; Heinle, Jeffrey; Gottlieb, Erin A; Vu, Eric; Brady, Ken M

    2018-04-18

    BackgroundElevated arterial blood pressure (ABP) is common after superior bidirectional cavopulmonary anastomosis (BCPA). The effects of elevated ABP after BCPA on cerebrovascular hemodynamics are unknown. We sought to determine the relationship between elevated ABP and cerebrovascular autoregulation after BCPA.MethodsProspective, observational study on infants with single-ventricle physiology after BCPA surgery. Continuous recordings of mean ABP, mean cavopulmonary artery pressure (PAP), near-infrared spectroscopy measures of cerebral oximetry (regional cerebral oxygen saturation (rSO 2 )), and relative cerebral blood volume index were obtained from admission to extubation. Autoregulation was measured as hemoglobin volume index (HVx). Physiologic variables, including the HVx, were tested for variance across ABP.ResultsSixteen subjects were included in the study. Elevated ABP post-BCPA was associated with both, elevated PAP (PABP and alterations in rSO 2 . Using piecewise regression, the relationship of PAP to ABP demonstrated a breakpoint at 68 mm Hg (interquartile range (IQR) 62-70 mm Hg). Curve fit of HVx as a function of ABP identified optimal ABP supporting robust autoregulation at a median ABP of 55 mm Hg (IQR 51-64 mm Hg).ConclusionsElevated ABP post-BCPA is associated with cerebrovascular dysautoregulation, and elevated PAP. The effects, of prolonged dysautoregulation within this population, require further study.Pediatric Research advance online publication, 18 April 2018; doi:10.1038/pr.2018.31.

  17. Potential hydrogen and oxygen partial pressures in legacy plutonium oxide packages at Oak Ridge

    Energy Technology Data Exchange (ETDEWEB)

    Veirs, Douglas K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-07-07

    An approach to estimate the maximum hydrogen and oxygen partial pressures within sealed containers is described and applied to a set of packages containing high-purity plutonium dioxide. The approach uses experimentally determined maximum hydrogen and oxygen partial pressures and scales the experimentally determined pressures to the relevant packaged material properties. The important material properties are the specific wattage and specific surface area (SSA). Important results from the experimental determination of maximum partial pressures are (1) the ratio of hydrogen to oxygen is stoichiometric, and (2) the maximum pressures increase with increasing initial rates of production. The material properties that influence the rates are the material specific wattage and the SSA. The unusual properties of these materials, high specific wattage and high SSA, result in higher predicted maximum pressures than typical plutonium dioxide in storage. The pressures are well within the deflagration range for mixtures of hydrogen and oxygen.

  18. Effects of Changes in Arterial Carbon Dioxide and Oxygen Partial Pressures on Cerebral Oximeter Performance.

    Science.gov (United States)

    Schober, Andrew; Feiner, John R; Bickler, Philip E; Rollins, Mark D

    2018-01-01

    Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P oxygen extraction (P < 0.0001). Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.

  19. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgstandard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  20. Effect of systemic nitric oxide synthase inhibition on optic disc oxygen partial pressure in normoxia and in hypercapnia.

    Science.gov (United States)

    Petropoulos, Ioannis K; Pournaras, Jean-Antoine C; Stangos, Alexandros N; Pournaras, Constantin J

    2009-01-01

    To investigate the effect of systemic nitric oxide synthase (NOS) inhibition on optic disc oxygen partial pressure (PO(2)) in normoxia and hypercapnia. Intervascular optic disc PO(2) was measured in 12 anesthetized minipigs by using oxygen-sensitive microelectrodes placed 0.1), despite a 21% increase of mean arterial pressure. Optic disc PO(2) increase under hypercapnia was blunted after L-NAME injection (DeltaPO(2) = 0.6 +/- 1.1 mm Hg; 3%; P > 0.1), and this effect was reversible by L-arginine. Moreover, L-NAME reduced the response to carbogen by 29% (DeltaPO(2) = 9.1 +/- 4.4 mm Hg; 49%; P = 0.01 versus before L-NAME). The response to hyperoxia was not affected. Whereas systemic NOS inhibition did not affect optic disc PO(2) in normoxia, a blunting effect was noted on the CO(2)-induced optic disc PO(2) increase. Nitric oxide appears to mediate the hypercapnic optic disc PO(2) increase.

  1. [Fasciocutaneous flap reliable by deep femoral artery perforator for the treatment of ischial pressure ulcers].

    Science.gov (United States)

    Gebert, L; Boucher, F; Lari, A; Braye, F; Mojallal, A; Ismaïl, M

    2018-04-01

    The surgical management of pressure ulcers in the paraplegic or quadriplegic population is marked by the high risk of recurrence in the long-term. In the current era of perforator flaps, newer reconstructive options are available for the management of pressure ulcers, decreasing the need to use the classically described muscular or musculocutaneous locoregional flaps. The coverage of ischial sores described in this article by a pedicled flap based on a deep femoral artery perforator, appears to be an effective first-line reconstructive option for the management of limited size pressure ulcers. A number of fifteen paraplegic or quadriplegic patients having at least one ischial bed sore with underlying osteomyelitis were included in this series. The approximate location of the deep femoral artery perforator was initially identified using the "The Atlas of the perforator arteries of the skin, the trunk and limbs", which was confirmed, with the use of a Doppler device. A fasciocutaneous transposition flap was elevated, with the pivot point based on the cutaneous bridge centered on the perforator, and then transposed to cover the area of tissue loss. The donor site was closed primarily. A total of fifteen patients were operated from November 2015 to November 2016. The series comprised of 16 first presentations of a stage 4 pressure ulcers associated with underlying osteomyelitis that were subsequently reconstructed by the pedicled deep femoral artery perforator flap. The healing rate and functional results were both satisfactory. Fasciocutaneous flap reliable by deep femoral artery perforator appears to have a promising role in the treatment of ischial pressure sores. It is an attractive option to spare the use of musculocutaneous flaps in the area. Thus this flap could be used as a first-line option to cover ischial pressure ulcers of limited size. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Arterial stiffness, cardiovagal baroreflex sensitivity and postural blood pressure changes in older adults: the Rotterdam Study

    NARCIS (Netherlands)

    Mattace-Raso, Francesco U. S.; van den Meiracker, Anton H.; Bos, Willem Jan; van der Cammen, Tischa J. M.; Westerhof, Berend E.; Elias-Smale, Suzette; Reneman, Robert S.; Hoeks, Arnold P. G.; Hofman, Albert; Witteman, Jacqueline C. M.

    2007-01-01

    Arterial stiffness may be involved in the impairment of the arterial baroreflex. In the present study the associations between arterial stiffness and cardiovagal baroreflex sensitivity (BRS) and between BRS and postural blood pressure (BP) changes were investigated within the framework of the

  3. Reciprocal Influence of Slow Waves Extracted in Intracranial Pressure, Arterial Pressure and Cerebral Blood Velocity Signals

    National Research Council Canada - National Science Library

    Cervenansky, F

    2001-01-01

    ...), and arterial blood pressure (ABP). To clarify the links, we compared two frequency methods based on coherence function to estimate the influence of ICP, ABP, and CBV on couples, respectively CBV-ABP, ICP-CBV and ICP-ABP, of slow waves...

  4. Photosynthesis and growth response of almond to increased atmospheric ozone partial pressures

    International Nuclear Information System (INIS)

    Retzlaff, W.A.; Williams, L.E.; DeJong, T.M.

    1992-01-01

    Uniform nursery stock of five almond cultivars [Prunus dulcis (Mill) D.A. Webb syn. P. amygdalus Batsch, cv. Butte, Carmel, Mission, Nonpareil, and Sonora] propagated on peach (P. domstica L. Batsch.) rootstock were exposed to three different atmospheric ozone (O 3 ) partial pressures. The trees were planted in open-top fumigation chambers on 19 Apr. 1989 at the University of California Kearny Agricultural Center located in the San Joaquin Valley of California. Exposures of the trees to three atmospheric O 3 partial pressures lasted from 1 June to 2 Nov. 1989. The mean 12-h [0800-2000 h Pacific Daylight Time (PDT)] O 3 partial pressures measured in the open-top chambers during the experimental period were 0.038, 0.060, and 0.112 μPa Pa -1 O 3 in the charcoal filtered, ambient, and ambient + O 3 treatments, respectively. Leaf net CO 2 assimilation, trunk cross-sectional area growth, and root, trunk, foliage, and total dry weight of Nonpareil were reduced by increased atmospheric O 3 partial pressures. Mission was unaffected by O 3 and Butte, Carmel, and Sonora were intermediate in their responses. Foliage of Nonpareil also abscised prematurely in the ambient and ambient + O 3 treatments. The results indicate that there are almond cultivars that are sensitive to O 3 exposure

  5. The effects of arterial carbon dioxide partial pressure and sevoflurane on capillary venous cerebral blood flow and oxygen saturation during craniotomy.

    Science.gov (United States)

    Klein, Klaus Ulrich; Glaser, Martin; Reisch, Robert; Tresch, Achim; Werner, Christian; Engelhard, Kristin

    2009-07-01

    Intraoperative routine monitoring of cerebral blood flow and oxygenation remains a technological challenge. Using the physiological principle of carbon dioxide reactivity of cerebral vasculature, we investigated a recently developed neuromonitoring device (oxygen-to-see, O2C device) for simultaneous measurements of regional cerebral blood flow (rvCBF), blood flow velocity (rvVelo), oxygen saturation (srvO2), and hemoglobin amount (rvHb) at the capillary venous level in patients subjected to craniotomy. Twenty-six neurosurgical patients were randomly assigned to anesthesia with 1.4% or 2.0% sevoflurane end-tidal concentration. After craniotomy, a fiberoptic probe was applied on a macroscopically healthy surface of cerebral tissue next to the site of surgery. Simultaneous measurements in 2 and 8 mm cerebral depth were performed in each patient during lower (35 mm Hg) and higher (45 mm Hg) levels (random order) of arterial carbon dioxide partial pressure (PaCO2). The principle of these measurements relies on the combination of laser-Doppler flowmetry (rvCBF, rvVelo) and photo-spectrometry (srvO2, rvHb). Linear models were fitted to test changes of end points (rvCBF, rvVelo, srvO2, rvHb) in response to lower and higher levels of PaCO2, 1.4% and 2.0% sevoflurane end-tidal concentration, and 2 and 8 mm cerebral depth. RvCBF and rvVelo were elevated by PaCO2 independent of sevoflurane concentration in 2 and 8 mm depth of cerebral tissue (P oxygen was decreased by elevated PaCO2. Unchanged levels of rvHb signify that there was no blood loss during measurements. Data suggest that the device allows detection of local changes in blood flow and oxygen saturation in response to different PaCO2 levels in predominant venous cerebral microvessels.

  6. Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

    Science.gov (United States)

    Voga, Gorazd

    2008-01-01

    The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.

  7. Impact of mean arterial pressure on sublingual microcirculation during cardiopulmonary bypass - secondary outcome from a randomised clinical trial

    DEFF Research Database (Denmark)

    Holmgaard, Frederik; Vedel, Anne G; Ravn, Hanne Berg

    2018-01-01

    . METHODS: Thirty-six cardiac surgery patients undergoing coronary artery bypass grafting were included and randomised to either low (40-50 mmHg) or high (70-80 mmHg) mean arterial pressure during cardiopulmonary bypass. Sidestream Dark Field video images were recorded from the sublingual mucosa. Recordings...... were analysed in a blinded fashion to quantify microcirculatory variables. RESULTS: Mean arterial pressure during cardiopulmonary bypass in the low target group was 45.0 mmHg (SD 5.3) vs. 67.2 mmHg (SD 8.9) in the high target group. We found no significant difference between the two groups......OBJECTIVE: In this substudy of a randomised, clinical trial, we explored the sublingual microcirculation during cardiac surgery at two different levels of blood pressure. We hypothesised that a higher mean arterial pressure during cardiopulmonary bypass would cause higher Microvascular Flow Index...

  8. Computing the partial volume of pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wiencke, Bent [Nestle USA, Corporate Engineering, 800 N. Brand Blvd, Glendale, CA 91203 (United States)

    2010-06-15

    The computation of the partial and total volume of pressure vessels with various type of head profiles requires detailed knowledge of the head profile geometry. Depending on the type of head profile the derivation of the equations can become very complex and the calculation process cumbersome. Certain head profiles require numerical methods to obtain the partial volume, which for most application is beyond the scope of practicability. This paper suggests a unique method that simplifies the calculation procedure for the various types of head profiles by using one common set of equations without the need for numerical or complex computation methods. For ease of use, all equations presented in this paper are summarized in a single table format for horizontal and vertical vessels. (author)

  9. Phylloquinone (vitamin K₁) intake and pulse pressure as a measure of arterial stiffness in older adults.

    Science.gov (United States)

    Vaccaro, Joan A; Huffman, Fatma G

    2013-01-01

    This study examined the relationships among ethnicity/race, lifestyle factors, phylloquinone (vitamin K₁) intake, and arterial pulse pressure in a nationally representative sample of older adults from four ethnic/racial groups: non-Hispanic Whites, non-Hispanic Blacks, Mexican Americans, and other Hispanics. This was a cross-sectional study of U.S. representative sample with data from the National Health and Nutrition Examination Surveys, 2007-2008 and 2009-2010 of adults aged 50 years and older (N = 5296). Vitamin K intake was determined by 24-hour recall. Pulse pressure was calculated as the difference between the averages of systolic blood pressure and diastolic blood pressure. Compared to White non-Hispanics, the other ethnic/racial groups were more likely to have inadequate vitamin K₁ intake. Inadequate vitamin K₁ intake was an independent predictor of high arterial pulse pressure. This was the first study that compared vitamin K₁ inadequacy with arterial pulse pressure across ethnicities/races in U.S. older adults. These findings suggest that vitamin K screening may be a beneficial marker for the health of older adults.

  10. Roles of Arterial Stiffness and Blood Pressure in Hypertension-Associated Cognitive Decline in Healthy Adults.

    Science.gov (United States)

    Hajjar, Ihab; Goldstein, Felicia C; Martin, Greg S; Quyyumi, Arshed A

    2016-01-01

    Although there is strong evidence that hypertension leads to cognitive decline, especially in the executive domain, the relationship between blood pressure and cognition has been conflicted. Hypertension is characterized by blood pressure elevation and increased arterial stiffness. We aimed at investigating whether arterial stiffness would be superior to blood pressure in predicting cognitive decline and explaining the hypertension-executive decline association. A randomly selected asymptomatic population (n=591, age=49.2 years, 70% women, 27% black, and education=18 years) underwent annual vascular and cognitive assessments. Cognition was assessed using computerized versions commonly used cognitive tests, and principal component analysis was used for deriving cognitive scores for executive function, memory, and working memory. Arterial stiffness was measured by carotid-femoral pulse wave velocity (PWV). Higher PWV, but not blood pressure, was associated with a steeper decline in executive (P=0.0002), memory (P=0.05), and working memory (P=0.02) scores after adjusting for demographics, education, and baseline cognitive performance. This remained true after adjusting for hypertension. Hypertension was associated with greater decline in executive score (P=0.0029) and those with combined hypertension and elevated PWV (>7 m/s) had the greatest decline in executive score (P value hypertension×PWV=0.02). PWV explained the association between hypertension and executive function (P value for hypertension=0.0029 versus 0.24 when adjusting for PWV). In healthy adults, increased arterial stiffness is superior to blood pressure in predicting cognitive decline in all domains and in explaining the hypertension-executive function association. Arterial stiffness, especially in hypertension, may be a target in the prevention of cognitive decline. © 2015 American Heart Association, Inc.

  11. Non-dipping blood pressure patterns and arterial stiffness parameters in patients with Behcet's disease.

    Science.gov (United States)

    Celik, Gulperi; Yilmaz, Sema; Ergulu Esmen, Serpil

    2015-12-01

    Behcet's disease is a multisystemic vasculitis involving veins and arteries of various sizes. Non-dipping status, augmentation index and pulse wave velocity are important determinants of cardiovascular mortality and morbidity. We investigated the non-dipping status and arterial stiffness in patients with Behcet's disease. In this cross-sectional study, we examined the vascular parameters of 96 patients with Behcet's disease (53% female) and 60 age- and sex-matched control subjects. The non-dipping status and arterial distensibility were assessed using a Mobil-O-Graph Arteriograph, an automatic oscillometric device. In total, 65.6% of 96 patients were systolic non-dippers, and 34.4% exhibited high augmentation indices. Ten percent of the control subjects were systolic non-dippers, and 11.7% exhibited high augmentation indices. Nocturnal decreases in systolic blood pressure correlated with central systolic blood pressure and diastolic blood pressure, as well as nocturnal decreases in diastolic blood pressure. Furthermore, non-dipper patients with Behcet's disease exhibited higher nocturnal cardiac outputs than did dipper patients with Behcet's disease. Augmentation index correlated negatively with C-reactive protein and correlated positively with both 24 h and nocturnal peripheral resistance, as well as 24 h pulse wave velocity. The patients with high augmentation indices exhibited lower creatinine clearance, as well as lower nocturnal cardiac outputs, higher 24 h peripheral resistance and higher 24 h pulse wave velocities. Non-dipping status and arterial stiffness may exacerbate the harmful cardiovascular effects of the other. In addition to conventional risk factors, non-dipping status and arterial stiffness should be examined during the follow-up evaluations of patients with Behcet's disease.

  12. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  13. Design improvement for partial penetration welds of Pressurizer heater sleeves to head junctures

    International Nuclear Information System (INIS)

    Kim, Jin-Seon; Lee, Kyoung-Jin; Park, Tae-Jung; Kim, Moo-Yong

    2007-01-01

    ASME Code, Section III allows partial penetration welds for openings for instrumentation on which there are substantially no piping reactions and requires to have interference fit or limited diametral clearance between nozzles and vessel penetrations for the partial penetration welds. Pressurizer heater sleeves are nonaxisymmetrically attached on the hill-side of bottom head by partial penetration welds. The excessive stresses in the partial penetration weld regions of the heater sleeves are induced by pressure and thermal transient loads and also by the deformation due to manual welding process. The purpose of this study is 1) to improve design for the partial penetration welds between heater sleeves to head junctures, 2) to demonstrate the structural integrity according to the requirements of ASME Code, Section III and 3) to improve welding procedure considering the proposed design

  14. Giant partially thrombosed 4 th ventricular posterior inferior cerebellar artery aneurysm; microsurgical management

    Directory of Open Access Journals (Sweden)

    Forhad Hossain Chowdhury

    2014-01-01

    Full Text Available A 42-year-old woman presented with a 3-month history of progressive occipital headache, vomiting, walking difficulty, and repeated fall. She had no history of sudden and severe headache. She had positive cerebellar signs, predominantly on the right side. Computerized tomography (CT scan, CT angiogram, and magnetic resonance image (MRI of the brain showed suspected partially thrombosed giant 4 th ventricular posterior inferior cerebellar artery aneurysm. Patient developed severe hypersensitivity reaction during both CT scan and MRI after contrast injection. Though needed, digital subtraction angiogram (DSA of cerebral vessels was not done. The aneurysm was managed by microsurgical clipping of the aneurysm neck and partial excision of thrombosed aneurysm. Here, we report the details of management of these difficult giant aneurysm without DSA.

  15. Functional role of diverse changes in sympathetic nerve activity in regulating arterial pressure during REM sleep.

    Science.gov (United States)

    Yoshimoto, Misa; Yoshida, Ikue; Miki, Kenju

    2011-08-01

    This study aimed to investigate whether REM sleep evoked diverse changes in sympathetic outflows and, if so, to elucidate why REM sleep evokes diverse changes in sympathetic outflows. Male Wistar rats were chronically implanted with electrodes to measure renal (RSNA) and lumbar sympathetic nerve activity (LSNA), electroencephalogram, electromyogram, and electrocardiogram, and catheters to measure systemic arterial and central venous pressure; these parameters were measured simultaneously and continuously during the sleep-awake cycle in the same rat. REM sleep resulted in a step reduction in RNSA by 36.1% ± 2.7% (P sleep. In contrast to REM sleep, RSNA, LSNA, systemic arterial pressure, and heart rate increased in a unidirectional manner associated with increases in physical activity levels in the order from NREM sleep, quiet awake, moving, and grooming state. Thus, the relationship between RSNA vs. LSNA and systemic arterial pressure vs. heart rate observed during REM sleep was dissociated compared with that obtained during the other behavioral states. It is suggested that the diverse changes in sympathetic outflows during REM sleep may be needed to increase systemic arterial pressure by balancing vascular resistance between muscles and vegetative organs without depending on the heart.

  16. Photosynthesis and growth response of almond to increased atmospheric ozone partial pressures

    Energy Technology Data Exchange (ETDEWEB)

    Retzlaff, W.A.; Williams, L.E. (Univ. of California, Davis (United States) Kearney Agricultural Center, Parlier, CA (United States)); DeJong, T.M. (Univ. of California, Davis (United States))

    Uniform nursery stock of five almond cultivars [Prunus dulcis (Mill) D.A. Webb syn. P. amygdalus Batsch, cv. Butte, Carmel, Mission, Nonpareil, and Sonora] propagated on peach (P. domstica L. Batsch.) rootstock were exposed to three different atmospheric ozone (O[sub 3]) partial pressures. The trees were planted in open-top fumigation chambers on 19 Apr. 1989 at the University of California Kearny Agricultural Center located in the San Joaquin Valley of California. Exposures of the trees to three atmospheric O[sub 3] partial pressures lasted from 1 June to 2 Nov. 1989. The mean 12-h [0800-2000 h Pacific Daylight Time (PDT)] O[sub 3] partial pressures measured in the open-top chambers during the experimental period were 0.038, 0.060, and 0.112 [mu]Pa Pa[sup [minus]1] O[sub 3] in the charcoal filtered, ambient, and ambient + O[sub 3] treatments, respectively. Leaf net CO[sub 2] assimilation, trunk cross-sectional area growth, and root, trunk, foliage, and total dry weight of Nonpareil were reduced by increased atmospheric O[sub 3] partial pressures. Mission was unaffected by O[sub 3] and Butte, Carmel, and Sonora were intermediate in their responses. Foliage of Nonpareil also abscised prematurely in the ambient and ambient + O[sub 3] treatments. The results indicate that there are almond cultivars that are sensitive to O[sub 3] exposure.

  17. The effects of stair climbing on arterial stiffness, blood pressure, and leg strength in postmenopausal women with stage 2 hypertension.

    Science.gov (United States)

    Wong, Alexei; Figueroa, Arturo; Son, Won-Mok; Chernykh, Oksana; Park, Song-Young

    2018-02-12

    Menopause is accompanied by a progressive arterial stiffening associated with increases in blood pressure (BP) and decline in muscular function. It is crucial to prevent or reduce the negative effects of menopause on vascular and muscular function by implementing appropriate lifestyle interventions, such as exercise training. We examined the effects of a stair climbing (SC) regimen on arterial stiffness (pulse wave velocity [PWV]), BP, and leg strength in postmenopausal women with stage 2 hypertension. Using a parallel experimental design, participants were randomly assigned to either SC (n = 21) or nonexercising control group (n = 20) for 12 weeks. Participants in the SC group trained 4 d/wk, climbing 192 steps 2 to 5 times/d. Participants' brachial-to-ankle PWV (baPWV), BP, and leg strength were measured at baseline and after 12 weeks of their assigned intervention. There was a significant group by time interaction (P hypertensive postmenopausal women. The decrease in arterial stiffness partially explained the improvements in SBP and leg strength. SC may be an effective intervention in the prevention and treatment of menopause/aging-related vascular complications and muscle weakness.

  18. Analysis of Arterial and Venous Blood Gases in Healthy Gyr Falcons ( Falco rusticolus ) Under Anesthesia.

    Science.gov (United States)

    Raghav, Raj; Middleton, Rachael; BSc, Rinshiya Ahamed; Arjunan, Raji; Caliendo, Valentina

    2015-12-01

    Arterial and venous blood gas analysis is useful in the assessment of tissue oxygenation and ventilation and in diagnosis of metabolic and respiratory derangements. It can be performed with a relatively small volume of blood in avian patients under emergency situations. Arterial and venous blood gas analysis was performed in 30 healthy gyr falcons ( Falco rusticolus ) under anaesthesia to establish temperature-corrected reference intervals for arterial blood gas values and to compare them to temperature-corrected venous blood gas values with a portable point-of-care blood gas analyzer (i-STAT 1, Abbott Laboratories, Abbott Park, IL, USA). Statistically significant differences were observed between the temperature-corrected values of pH, partial pressure of carbon dioxide (Pco2), and partial pressure of oxygen (Po2) and the corresponding nontemperature-corrected values of these parameters in both arterial and venous blood. Values of temperature-corrected pH, temperature-corrected Pco2, bicarbonate concentrations, and base excess of extra cellular fluid did not differ significantly between arterial and venous blood, suggesting that, in anesthetized gyr falcons, venous blood gas analysis can be used in place of arterial blood gas analysis in clinical situations. Values for hematocrit, measured by the point-of-care analyzer, were significantly lower compared with those obtained by the microhematocrit method.

  19. Oxygen partial pressure effects on the RF sputtered p-type NiO hydrogen gas sensors

    Science.gov (United States)

    Turgut, Erdal; Çoban, Ömer; Sarıtaş, Sevda; Tüzemen, Sebahattin; Yıldırım, Muhammet; Gür, Emre

    2018-03-01

    NiO thin films were grown by Radio Frequency (RF) Magnetron Sputtering method under different oxygen partial pressures, which are 0.6 mTorr, 1.3 mTorr and 2.0 mTorr. The effects of oxygen partial pressures on the thin films were analyzed through Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), X-ray Diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS) and Hall measurements. The change in the surface morphology of the thin films has been observed with the SEM and AFM measurements. While nano-pyramids have been obtained on the thin film grown at the lowest oxygen partial pressure, the spherical granules lower than 60 nm in size has been observed for the samples grown at higher oxygen partial pressures. The shift in the dominant XRD peak is realized to the lower two theta angle with increasing the oxygen partial pressures. XPS measurements showed that the Ni2p peak involves satellite peaks and two oxidation states of Ni, Ni2+ and Ni3+, have been existed together with the corresponding splitting in O1s spectrum. P-type conductivity of the grown NiO thin films are confirmed by the Hall measurements with concentrations on the order of 1013 holes/cm-3. Gas sensor measurements revealed minimum of 10% response to the 10 ppm H2 level. Enhanced responsivity of the gas sensor devices of NiO thin films is shown as the oxygen partial pressure increases.

  20. Effect of substrate temperature and oxygen partial pressure on RF sputtered NiO thin films

    Science.gov (United States)

    Cheemadan, Saheer; Santhosh Kumar, M. C.

    2018-04-01

    Nickel oxide (NiO) thin films were deposited by RF sputtering process and the physical properties were investigated for varying substrate temperatures and oxygen partial pressure. The variation of the crystallographic orientation and microstructure of the NiO thin films with an increase in substrate temperature were studied. It was observed that NiO thin films deposited at 350 °C shows relatively good crystalline characteristics with a preferential orientation along (111) plane. With the optimum substrate temperature of 350 °C, the NiO thin films were deposited under various oxygen partial pressures at the same experimental conditions. The structural, optical and electrical properties of NiO thin films under varying oxygen partial pressure of 10%–50% were investigated. From XRD it is clear that the films prepared in the pure argon atmosphere were amorphous while the films in oxygen partial pressure exhibited polycrystalline NiO phase. SEM and AFM investigations unveil that the higher substrate temperature improves the microstructure of the thin films. It is revealed that the NiO thin films deposited at oxygen partial pressure of 40% and a substrate temperature of 350 °C, showed higher electrical conductivity with p-type characteristics.

  1. [Effects of gap junction blocking on the oxygen partial pressure in acupoints of the bladder meridian].

    Science.gov (United States)

    Wang, Qi; Yu, Wei-Chang; Jiang, Hong-Zhi; Chen, Sheng-Li; Zhang, Ming-Min; Kong, E-Sheng; Huang, Guang-Ying

    2010-12-01

    To explore the relation between gap junction and meridian phenomenon. The oxygen partial pressure in acupoints [see text for formula] and in their corresponding non-acupoints of the Bladder Meridian was observed with the needle-type tissue oxygen tension sensor in the gap junction blocking goats by 1-Heptanol injection and the Connexin 43 (Cx43) gene knockout mice. (1) The oxygen partial pressure in acupoints of Bladder Meridian on goats was higher than that in non-acupoints after 1-Heptanol injection with significant differences between them (both P oxygen partial pressure in acupoints of Bladder Meridian on goats increased significantly after injecting 1-Heptanol as compare with that either injecting normal saline or injecting nothing with significant differences between them (all P oxygen partial pressure in acupoints of the Bladder Meridian was significantly higher than that in the non-acupoint controls in Cx43 wild type (WT) mice (all P oxygen partial pressure between acupoints and non-acupoint controls showed no significant differences (all P > 0.05). (4) In acupoints, the oxygen partial pressure in Cx43 WT mice was significantly higher than that in Cx43 HT mice (all P 0.05). Gap junction maybe the essential factor in signal transduction of acupuncture.

  2. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  3. [Doppler ultrasound evaluation of aortic insufficiency using half-pressure time. Absence of arterial rigidity influence].

    Science.gov (United States)

    Kalotka-Bratek, H; Drobinski, G; Klimczak, K; Busquet, P; Fraysse, J B; Bejean-Lebuisson, A; Grosgogeat, Y

    1989-02-01

    In 20 patients with pure aortic regurgitation we studied the relationship between the severity of regurgitation, as assessed haemodynamically by the percentage of leakage (%L), and the half-pressure (T 1/2 P) and half-velocity (T 1/2 V) times, as obtained from doppler aortic blood velocity curves, taking into account the rigidity of the systemic vascular circuit characterized by the pressure wave propagation velocity (PWPV). The systemic arterial circuit was supple in 14 patients (PWPV less than 7.5 m/sec) and rigid in 6 patients (PWPV greater than 7.5 m/sec). The regression slopes between %L and T 1/2 P and between %L and T 1/2 V were calculated with their confidence limits in the 14 patients with supple arteries. The 6 patients with rigid arteries fitted into this nomogram, thus demonstrating that systemic arterial rigidity makes no difference in the relationship between %L and doppler indices. The half-velocity and half-pressure times measured by doppler ultrasound were acquired from a velocity signal directly determined by the aortic regurgitation, without any detectable effect of vascular circuit rigidity. Being equivalent by nature to the signal decrease time constant, they are independent of the absolute protodiastolic value of diastolic pressure gradient or blood flow velocity. For this reason these two doppler parameters are reliable to evaluate the severity of aortic regurgitation.

  4. Long-term effect of prazosin administration on blood pressure, heart and structure of coronary artery of young spontaneously hypertensive rats.

    Science.gov (United States)

    Kristek, F; Koprdova, R

    2011-06-01

    The sympathetic nervous system belongs to the essential systems participating in blood pressure (BP) regulation. Inhibitory intervention into the key point of its operation (alfa 1 adrenoceptors) in the prehypertensive period of spontaneously hypertensive rats (SHR) might affect the development of the hypertension in later ontogenic periods. We studied the long-term effect of prazosin administration on the cardiovascular system of young Wistar rats and SHR. Four-week-old animals were used: Wistar rats, SHR, and Wistar rats and SHR receiving prazosin (10 mg/kg/day in tap water) by gavage. Blood pressure (BP) was measured weekly by the plethysmographic method. After six weeks under anaesthesia, the carotid artery was cannulated for BP registration, and the jugular vein was cannulated for administration of drugs. Afterwards, the animals were perfused with a glutaraldehyde fixative at a pressure of 120 mmHg. The septal branch of the left descending coronary artery was processed using electron microscopy. The prazosin administration evoked the following results in both groups: a decrease of BP and heart/body weight ratio, enhancement of hypotensive responses to acetylcholine (0.1 μg, 1 μg, and 10 μg), and an increase in the inner diameter of the coronary artery without changes in wall thickness, cross sectional area (CSA) (tunica intima+media), CSA of smooth muscle cells, and extracellular matrix. In the SHR group, a reduction was observed in BP increase after noradrenaline (1 μg) application. CSA of endothelial cells which was decreased in the SHR (compared to the control Wistar rats) was increased after prazosin treatment (up to control value). Long-term prazosin administration from early ontogeny partially prevented some pathological alterations in the cardiovascular system of SHR.

  5. Partially thrombosed giant aneurysm arising from a distal anterior inferior cerebellar artery–posterior inferior cerebellar artery variant: A case report

    Directory of Open Access Journals (Sweden)

    Hidetoshi Ooigawa

    2015-09-01

    Full Text Available Anterior inferior cerebellar artery (AICA–posterior inferior cerebellar artery (PICA is a well-known variant in cerebral arteries. However, aneurysms located on the variant are rare and a giant one has not been reported. We report a case of a partially thrombosed giant aneurysm arising from an AICA–PICA variant. The patient was a 42-year-old man who presented with right hearing loss and facial numbness associated with left hemidysesthesia. Magnetic resonance imaging revealed an approximately 3.0-cm mass lesion at the right cerebello-pontine angle (CPA. Angiography showed a partially thrombosed aneurysm arising from the right AICA–PICA. The aneurysm was treated with endovascular trapping and surgical thrombectomy. Although cerebral aneurysm is known to occur at this site, this case provides awareness, that manifestations of aneurysms in the CPA include progressive multiple cranial nerve palsies and sensory disturbance caused by brainstem compression.

  6. Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

    Science.gov (United States)

    Martin, Jeffrey S; Borges, Alexandra R; Christy, John B; Beck, Darren T

    2015-10-01

    Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.

  7. Contrast analysis of the partial splenic artery embolization with splenectomy

    International Nuclear Information System (INIS)

    Lu Wusheng; He Qing; Zheng Zhiyong; Wu Shaoping; Xu Dawei

    2006-01-01

    Objective: To analyze the effects and the complications of partial splenic artery embolization (PSE) and splenectomy offering a feasible way to choose different therapeutic methods for hypersplenism. Methods: Forty-six patients treated with PSE and thirty-three undergone splenectomy were compared for their effectivenesses and complications in treating hypersplenism. Results: Thrombocyte and leucocyte counts increased markedly after the two kinds of treatment (P 0.05). The complication rate of the PSE was far more than that of the splenectomy (P<0.001). Conclusions Splenectomy is prior to PSE on patients with large mount of ascites, serious portal hypertension and splenomegaly. PSE is suitable for patients with poor liver function, blood coagulation disturbance, liver cancer complicated with hypersplenism and aging. (authors)

  8. Does mean arterial blood pressure scale with body mass in mammals?

    DEFF Research Database (Denmark)

    Poulsen, C B; Wang, T; Assersen, K

    2018-01-01

    For at least the last 30 years, it has been discussed whether mean arterial blood pressure (MAP) is independent of body mass or whether it increases in accordance with the vertical height between the heart and the brain. The debate has centred on the most appropriate mathematical models for analy......For at least the last 30 years, it has been discussed whether mean arterial blood pressure (MAP) is independent of body mass or whether it increases in accordance with the vertical height between the heart and the brain. The debate has centred on the most appropriate mathematical models......-Altman analysis showed a bias of 1 mm Hg with 95% confidence interval (from -35 to 36 mm Hg); that is, the limits of agreement between radiotelemetric studies and studies in restrained animals were double the supposed difference in the MAP between the mouse and elephant. In conclusion, the existing literature...

  9. Relationship between pre-extubation positive endexpiratory pressure and oxygenation after coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Reijane Oliveira Lima

    2015-08-01

    Full Text Available Abstract Introduction After removal of endotracheal tube and artificial ventilation, ventilatory support should be continued, offering oxygen supply to ensure an arterial oxygen saturation close to physiological. Objective: The aim of this study was to investigate the effects of positive-end expiratory pressure before extubation on the oxygenation indices of patients undergoing coronary artery bypass grafting. Methods: A randomized clinical trial with seventy-eight patients undergoing coronary artery bypass grafting divided into three groups and ventilated with different positive-end expiratory pressure levels prior to extubation: Group A, 5 cmH2O (n=32; Group B, 8 cmH2O (n=26; and Group C, 10 cmH2O (n=20. Oxygenation index data were obtained from arterial blood gas samples collected at 1, 3, and 6 h after extubation. Patients with chronic pulmonary disease and those who underwent off-pump, emergency, or combined surgeries were excluded. For statistical analysis, we used Shapiro-Wilk, G, Kruskal-Wallis, and analysis of variance tests and set the level of significance at P<0.05. Results Groups were homogenous with regard to demographic, clinical, and surgical variables. There were no statistically significant differences between groups in the first 6 h after extubation with regard to oxygenation indices and oxygen therapy utilization. Conclusion: In this sample of patients undergoing coronary artery bypass grafting, the use of different positive-end expiratory pressure levels before extubation did not affect gas exchange or oxygen therapy utilization in the first 6 h after endotracheal tube removal.

  10. Arterial Blood Pressure Induces Transient C4b-Binding Protein in Human Saphenous Vein Grafts.

    Science.gov (United States)

    Kupreishvili, Koba; Meischl, Christof; Vonk, Alexander B A; Stooker, Wim; Eijsman, Leon; Blom, Anna M; Quax, Paul H A; van Hinsbergh, Victor W M; Niessen, Hans W M; Krijnen, Paul A J

    2017-05-01

    Complement is an important mediator in arterial blood pressure-induced vein graft failure. Previously, we noted activation of cell protective mechanisms in human saphenous veins too. Here we have analyzed whether C4b-binding protein (C4bp), an endogenous complement inhibitor, is present in the vein wall. Human saphenous vein segments obtained from patients undergoing coronary artery bypass grafting (n = 55) were perfused in vitro at arterial blood pressure with either autologous blood for 1, 2, 4, or 6 hr or with autologous blood supplemented with reactive oxygen species scavenger N-acetylcysteine. The segments were subsequently analyzed quantitatively for presence of C4bp and complement activation product C3d using immunohistochemistry. Perfusion induced deposition of C3d and C4bp within the media of the vessel wall, which increased reproducibly and significantly over a period of 4 hr up to 3.8% for C3d and 81% for C4bp of the total vessel area. Remarkably after 6 hr of perfusion, the C3d-positive area decreased significantly to 1.3% and the C4bp-positive area to 19% of the total area of the vein. The areas positive for both C4bp and C3d were increased in the presence of N-acetylcysteine. Exposure to arterial blood pressure leads to a transient presence of C4bp in the vein wall. This may be part of a cell-protective mechanism to counteract arterial blood pressure-induced cellular stress and inflammation in grafted veins. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Pressure profile and morphology of the arteries along the giraffe limb

    DEFF Research Database (Denmark)

    Østergaard, Kristine Hovkjær; Bertelsen, Mads Frost; Brøndum, Emil Toft

    2011-01-01

    Giraffes are the tallest animals on earth and the effects of gravity on their cardiovascular system have puzzled physiologists for centuries. The authors measured arterial and venous pressure in the foreleg of anesthetized giraffes, suspended in upright standing position, and determined the ratio......-fold higher innervation density than the immediate distal and proximal regions. The sudden narrowing was also observed in the hind legs of neonates, indicating that it does not develop as an adaptation to the high transmural pressure in the standing giraffe. More likely it represents a preadaptation...... to the high pressures experienced by adult giraffes....

  12. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  13. [The heart catheter table is not the operating table : Intraindividual comparison of pulmonary artery pressures].

    Science.gov (United States)

    Ziegler, M U; Reinelt, H

    2018-05-01

    Patients undergoing cardiac surgery need extensive and invasive monitoring, which needs to be individually adapted for each patient and requires a diligent risk-benefit analysis. The use of a pulmonary artery catheter (PAC) seems to be justifiable in certain cases; therefore, the preoperative diagnosis of pulmonary hypertension represents an indication for perioperative monitoring with PAC in the S3 guidelines of the German Society for Anesthesiology and Intensive Care Medicine (DGAI). In many cases, however, this preoperative diagnosis cannot be confirmed intraoperatively. We wanted to find out whether this is just an impression or whether there actually are significant differences between preoperative, intraoperative and postoperative pulmonary artery pressures. After obtaining ethical approval, we retrospectively compared the pulmonary pressures of cardiac surgery patients with an elevated pulmonary pressure during preoperative right heart catheterization with those obtained intraoperatively and postoperatively by means of a PAC. All patients with a preoperatively documented pulmonary artery pressure of 40 mmHg or above and an intraoperative use of a PAC during a 4-year period were included. Exclusion criteria were intracardiac shunts, cardiogenic shock, emergency procedures, pulmonary hypertension of non-cardiac origin and a time span of more than 1 year between right heart catheterization and surgery. We included 90 patients. In the whole group and in the subgroups (according to diagnosis, time elapsed between heart catheterization and operation and pulmonary pressure), there were significant differences between preoperative and intraoperative pulmonary and systemic pressures. Systemic and pulmonary artery pressures were significantly higher during preoperative catheterization than intraoperatively. The systemic systolic pressure/systolic pulmonary pressure ratio, however, remained constant. The intraoperative and postoperative systemic and pulmonary

  14. Peripheral Chemoreception and Arterial Pressure Responses to Intermittent Hypoxia

    OpenAIRE

    Prabhakar, Nanduri R.; Peng, Ying-Jie; Kumar, Ganesh K.; Nanduri, Jayasri

    2015-01-01

    Carotid bodies are the principal peripheral chemoreceptors for detecting changes in arterial blood oxygen levels, and the resulting chemoreflex is a potent regulator of blood pressure. Recurrent apnea with intermittent hypoxia (IH) is a major clinical problem in adult humans and infants born preterm. Adult patients with recurrent apnea exhibit heightened sympathetic nerve activity and hypertension. Adults born preterm are predisposed to early onset of hypertension. Available evidence suggests...

  15. Determining the Arterial Blood Pressure of People Living in Yesilyurt Local Healthcare Office

    Directory of Open Access Journals (Sweden)

    Feyza Dereli

    2009-02-01

    Full Text Available AIM: Whereas the prevalance of arterial blood pressure which was a chronical health problem was 20%-25% among 30 year-old people, them showing an increase in aging, the percentage went as high as 50% in 60’s and later ages. What was that worrisome was that despite the high prevalance, only half of these received treathment. This is study was descriptively and cross-sectionally planned to determine whether the people asking their tensions to be measured in and around the Yesilyurt local healthcare office region. METHODS: The environment of the research consisted of 1400 people over 35 age and registered Yesilyurt Local healthcare Office and the whole of the environment were included in this sample. The study was conducted over 340 voluntaries. The data was collected by a questionnaire of 14 questions containing socio-demografic features and by measuring the arterial blood pressure, height and weight of the individuals. In the evaluation of the data, chi-square test was used and the level of significantly was accepted as 0.05. RESULTS: In this study, the rate of high sistolic blood pressure was found to be 21.47% and the rate of high diastolic blood pressure to be 8.23%. It was determined that age and body mass index varrieties were effective on sistolic hipertension. It was also found that in their behaviors of the use of hypertensive medicine, of regular arterial pressure controls and of having the hypertesion diagnosis significant differnces varied statistically on both sistolic and diastolic blood pressure people having. CONCLUSION: In order to improve the health, informative information abouth hypertension was provided for the participants for too days consisting of 4 sessions. [TAF Prev Med Bull 2009; 8(1.000: 53-58

  16. The influence of the oxygen partial pressure on the quasi-ternary system Cr-Mn-Ti-oxide

    International Nuclear Information System (INIS)

    Garcia-Rosales, C.; Schulze, H.A.; Naoumidis, A.; Nickel, H.

    1991-05-01

    The passivation layers formed by the oxidizing corrosion of high temperature alloys consist primarily of oxides and mixed oxides of the elements chromium, manganese and titanium. For a reproducible formation and characterization of such oxide layers it is necessary to know the phase equilibria of these oxide systems at temperature and oxygen partial pressure conditions which will be relevant during their application. For the investigation of the quasi-ternary system Cr-Mn-Ti-oxide, oxide powders were prepared and annealed at 1000deg C under different oxygen partial pressures ranging from 0.21 bar to 10 -21 bar. Phase identification and determination of lattice parameter using X-ray diffraction analysis as well as the direct measurement of phase boundaries as a function of oxygen partial pressure using the emf-methode were carried out for these investigations. In the quasi-ternary system Cr-Mn-Ti-oxide the spinels play a decisive role in the oxigen partial pressure range examined. The spinel MnCr 2 O 4 may be regarded as the most significant compound. Part of the chronium can be replaced by trivalent manganese at high oxygen partial pressures and by trivalent titanium at low pressures, and the formation of a solid solution with the spinel Mn 2 TiO 4 is possible in all cases. In this way a coherent single-phase spinel region is observed which extends over the entire oxygen partial pressure range form 0.21 bar to 10 -21 bar examined at 1000deg C. (orig.) [de

  17. Comparison of Doppler and oscillometric ankle blood pressure measurement in patients with angiographically documented lower extremity arterial occlusive disease.

    Science.gov (United States)

    Nukumizu, Yoshihito; Matsushita, Masahiro; Sakurai, Tsunehisa; Kobayashi, Masayoshi; Nishikimi, Naomichi; Komori, Kimihiro

    2007-01-01

    To assess the reliability of the oscillometric method in patients with peripheral vascular disease, ankle blood pressure measurement by Doppler and oscillometry was compared. This study represents a prospective, non-blinded examination of pressure measurements in 168 patients. Twenty-two patients were included who had abdominal aortic aneurysms (AAA) and 146 had peripheral arterial occlusive disease (PAOD). Patients with PAOD were divided into 2 groups according to angiography results: a crural artery occlusion group (CAO, n = 32), and a no crural artery occlusion group (NCAO, n = 114). All subjects underwent pressure measurement by both Doppler and oscillometry. The correlation coefficient was 0.928 in AAA patients and 0.922 in PAOD patients. In CAO patients, there were significantly fewer patients whose oscillometric pressure was equivalent to the Doppler pressure (DP), as compared to NCAO patients, because the oscillometric pressure (OP) was 10% higher than DP in 44% of CAO patients. A high correlation exists between Doppler and oscillometric ankle pressure measurements irrespective of the type of vascular disease. However, the oscillometric method could not be substituted for the Doppler method completely, because there were several patients whose OP was greater than DP especially in those with crural artery occlusive disease.

  18. Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress

    NARCIS (Netherlands)

    Harms, M.P.M.; Wesseling, K.H.; Pott, F.; Jenstrup, M.; Goudoever, J. van; Secher, N.H.; Lieshout, J.J. van

    1999-01-01

    The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and

  19. Low arterial pressure on admission as a predictor of mortality in operated patients with type A aortic dissection

    Directory of Open Access Journals (Sweden)

    Pavlović Katica

    2011-01-01

    Full Text Available Background/Aim. Hypertension is a known predictor of proximal aortic dissection, but it is not commonly present in these patients on presentation. The associations between ascending aorta with left ventricular hypertrophy, cardiovascular risk factors and coronary atherosclerosis, and outcome of these patients are not fully elucidated. Methods. This retrospective study included 55 consecutive patients with acute type A aortic dissection treated surgically in our institution during the last 2 years. The diagnosis was based on imaging studies. Diameter of ascending aorta was measured with echocardiography. Results. The mean age of the patients was 55.4 ± 12.19 years, and 72.7% were men. A history of arterial hypertension was present in 76.4% of the patients. Maximal ascending aorta diameter was 4.09 ± 0.59 cm, while patients with frank aneurysm accounted for 5.5%. Systolic blood pressure on admission was < 150 mmHg in 58.2% of the patients. Diastolic blood pressure on admission was < 90 mmHg in 54.5% of the patients. Mean arterial pressure on admission was 104.9 ± 24.6 mmHg. No correlations were demonstrated between maximal ascending aorta diameter and diameter of the left ventricular wall, any obtained risk factor and with coronary artery atherosclerosis (p > 0.05. After six months 11 (20% patients died, while intrahospital mortality was 72%. According to logistic regression analysis which included traditional risk factors, echo parameters, coronary artery disease and logistic euro scor, mean arterial blood pressure was the independent predictor of a six-month mortality [RR 0.956; CI (0.918-0.994 ; p = 0.024]. Conclusion. In our population the acute type A aortic dissection occurred rarely in the setting of frank ascending aortic aneurysms > 5.0 cm. The majority of patients had a history of arterial hypertension. A history of arterial hypertension was not associated with maximal ascending aorta diameter. Mean arterial blood pressure was the

  20. Imaging and modeling of acute pressure-induced changes of collagen and elastin microarchitectures in pig and human resistance arteries.

    Science.gov (United States)

    Bloksgaard, Maria; Leurgans, Thomas M; Spronck, Bart; Heusinkveld, Maarten H G; Thorsted, Bjarne; Rosenstand, Kristoffer; Nissen, Inger; Hansen, Ulla M; Brewer, Jonathan R; Bagatolli, Luis A; Rasmussen, Lars M; Irmukhamedov, Akhmadjon; Reesink, Koen D; De Mey, Jo G R

    2017-07-01

    The impact of disease-related changes in the extracellular matrix (ECM) on the mechanical properties of human resistance arteries largely remains to be established. Resistance arteries from both pig and human parietal pericardium (PRA) display a different ECM microarchitecture compared with frequently used rodent mesenteric arteries. We hypothesized that the biaxial mechanics of PRA mirror pressure-induced changes in the ECM microarchitecture. This was tested using isolated pig PRA as a model system, integrating vital imaging, pressure myography, and mathematical modeling. Collagenase and elastase digestions were applied to evaluate the load-bearing roles of collagen and elastin, respectively. The incremental elastic modulus linearly related to the straightness of adventitial collagen fibers circumferentially and longitudinally (both R 2 ≥ 0.99), whereas there was a nonlinear relationship to the internal elastic lamina elastin fiber branching angles. Mathematical modeling suggested a collagen recruitment strain (means ± SE) of 1.1 ± 0.2 circumferentially and 0.20 ± 0.01 longitudinally, corresponding to a pressure of ~40 mmHg, a finding supported by the vital imaging. The integrated method was tested on human PRA to confirm its validity. These showed limited circumferential distensibility and elongation and a collagen recruitment strain of 0.8 ± 0.1 circumferentially and 0.06 ± 0.02 longitudinally, reached at a distending pressure below 20 mmHg. This was confirmed by vital imaging showing negligible microarchitectural changes of elastin and collagen upon pressurization. In conclusion, we show here, for the first time in resistance arteries, a quantitative relationship between pressure-induced changes in the extracellular matrix and the arterial wall mechanics. The strength of the integrated methods invites for future detailed studies of microvascular pathologies. NEW & NOTEWORTHY This is the first study to quantitatively relate pressure

  1. Viscoelastic properties of doped-ceria under reduced oxygen partial pressure

    DEFF Research Database (Denmark)

    Teocoli, Francesca; Esposito, Vincenzo

    2014-01-01

    The viscoelastic properties of gadolinium-doped ceria (CGO) powder compacts are characterized during sintering and cooling under reduced oxygen partial pressure and compared with conventional sintering in air. Highly defective doped ceria in reducing conditions shows peculiar viscoelastic...

  2. Does donor arterial partial pressure of oxygen affect outcomes after lung transplantation? A review of more than 12,000 lung transplants.

    Science.gov (United States)

    Zafar, Farhan; Khan, Muhammad S; Heinle, Jeffrey S; Adachi, Iki; McKenzie, E Dean; Schecter, Marc G; Mallory, George B; Morales, David L S

    2012-04-01

    In lung transplantation (LTx), the arterial partial pressure of oxygen (PaO(2)) is traditionally regarded as critical information for assessment of donor lung function. Each center sets its own thresholds; by convention, a donor PaO(2) of less than 300 mm Hg has been considered disqualifying. Limited literature exists to support such a practice. We analyzed all LTxs performed in the United States over a 9-year period to assess the effect of donor PaO(2) on graft survival. The United Network for Organ Sharing (UNOS) database was queried for LTx (January 2000-November 2009). Of 12,545 LTx performed, 12,045 (96%) had donor PaO(2) data on a fraction of inspired oxygen of 1.0, recorded at the time of procurement. Mean donor PaO(2) was 407 ± 140 mm Hg. The majority of LTxs had a donor PaO(2) greater than 300 mm Hg (9593 (80%]) whereas PaO(2) was 200 mm Hg or less in 1830 (15%) and 201 to 300 in 582 (5%) donors. Use of donors with a PaO(2) of less than 200 increased over time from 5% (45) in 2000 to 21% (295) in 2009 (P = .002). Kaplan-Meier survival analysis showed no difference in graft survival with differing donor PaO(2)s, irrespective of whether patients had a single or double LTx. A Cox multivariable analysis of 21 donor characteristics demonstrated that donor PaO(2) had no association with graft survival. Donor PaO(2) levels did not affect graft survival. The use of donors with lower PaO(2)s could substantially increase the donor pool. We are not suggesting that donor PaO(2) is not important when assessing potential lung donors but its level of importance in regard to other criteria appears less than previously believed. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  3. Hydro-isomerization of n-hexane on bi-functional catalyst: Effect of total and hydrogen partial pressures

    Science.gov (United States)

    Thoa, Dao Thi Kim; Loc, Luu Cam

    2017-09-01

    The effect of both total pressure and hydrogen partial pressure during n-hexane hydro-isomerization over platinum impregnated on HZSM-5 was studied. n-Hexane hydro-isomerization was conducted at atmospheric pressure and 0.7 MPa to observe the influence of total pressure. In order to see the effect of hydrogen partial pressure, the reaction was taken place at different partial pressure of hydrogen varied from 307 hPa to 718 hPa by dilution with nitrogen to keep the total pressure at 0.1 MPa. Physico-chemical characteristics of catalyst were determined by the methods of nitrogen physi-sorption BET, SEM, XRD, TEM, NH3-TPD, TPR, and Hydrogen Pulse Chemi-sorption. Activity of catalyst in the hydro-isomerization of n-hexane was studied in a micro-flow reactor in the temperature range of 225-325 °C; the molar ratio H2/ hydrocarbon: 5.92, concentration of n-hexane: 9.2 mol.%, GHSV 2698 h-1. The obtained catalyst expressed high acid density, good reducing property, high metal dispersion, and good balance between metallic and acidic sites. It is excellent contact for n-hexane hydro-isomerization. At 250 °C, n-hexane conversion and selectivity were as high as 59-76 % and 85-99 %, respectively. It was found that catalytic activity was promoted either by total pressure or hydrogen partial pressure. At total pressure of 0.7 MPa while hydrogen partial pressure of 718 hPa, catalyst produced 63 RON liquid product containing friendly environmental iso-paraffins which is superior blending stock for green gasoline. Hydrogen did not only preserve catalyst actives by depressing hydrocracking and removing coke precursors but also facilitated hydride transfer step in the bi-functional bi-molecular mechanism.

  4. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cary, Theodore W.; Sultan, Laith R.; Sehgal, Chandra M., E-mail: sehgalc@uphs.upenn.edu [Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Reamer, Courtney B.; Mohler, Emile R. [Department of Medicine, Division of Cardiovascular Medicine, Section of Vascular Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2014-02-15

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.

  5. Quantifying [{sup 18}F]fluorodeoxyglucose uptake in the arterial wall: the effects of dual time-point imaging and partial volume effect correction

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, Bjoern A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark); Bashyam, Arjun; Ramachandran, Abhinay; Gholami, Saeid; Houshmand, Sina; Salavati, Ali; Werner, Tom; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); University of Groningen, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen (Netherlands)

    2015-08-15

    The human arterial wall is smaller than the spatial resolution of current positron emission tomographs. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake. We evaluated the impact of a novel method for partial volume effect (PVE) correction with contrast-enhanced CT (CECT) assistance on quantification of arterial wall {sup 18}F-FDG uptake at different imaging time-points. Ten subjects were assessed by CECT imaging and dual time-point PET/CT imaging at approximately 60 and 180 min after {sup 18}F-FDG administration. For both time-points, uptake of {sup 18}F-FDG was determined in the aortic wall by calculating the blood pool-corrected maximum standardized uptake value (cSUV{sub MAX}) and cSUV{sub MEAN}. The PVE-corrected SUV{sub MEAN} (pvcSUV{sub MEAN}) was also calculated using {sup 18}F-FDG PET/CT and CECT images. Finally, corresponding target-to-background ratios (TBR) were calculated. At 60 min, pvcSUV{sub MEAN} was on average 3.1 times greater than cSUV{sub MAX} (P <.0001) and 8.5 times greater than cSUV{sub MEAN} (P <.0001). At 180 min, pvcSUV{sub MEAN} was on average 2.6 times greater than cSUV{sub MAX} (P <.0001) and 6.6 times greater than cSUV{sub MEAN} (P <.0001). This study demonstrated that CECT-assisted PVE correction significantly influences quantification of arterial wall {sup 18}F-FDG uptake. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake with PET. (orig.)

  6. Biomass hydrolysis inhibition at high hydrogen partial pressure in solid-state anaerobic digestion.

    Science.gov (United States)

    Cazier, E A; Trably, E; Steyer, J P; Escudie, R

    2015-08-01

    In solid-state anaerobic digestion, so-called ss-AD, biogas production is inhibited at high total solids contents. Such inhibition is likely caused by a slow diffusion of dissolved reaction intermediates that locally accumulate. In this study, we investigated the effect of H2 and CO2 partial pressure on ss-AD. Partial pressure of H2 and/or CO2 was artificially fixed, from 0 to 1 557mbars for H2 and from 0 to 427mbars for CO2. High partial pressure of H2 showed a significant effect on methanogenesis, while CO2 had no impact. At high [Formula: see text] , the overall substrate degradation decreased with no accumulation of metabolites from acidogenic bacteria, indicating that the hydrolytic activity was specifically impacted. Interestingly, such inhibition did not occur when CO2 was added with H2. This result suggests that CO2 gas transfer is probably a key factor in ss-AD from biomass. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Optimizing the physical ergonomics indices for the use of partial pressure suits.

    Science.gov (United States)

    Ding, Li; Li, Xianxue; Hedge, Alan; Hu, Huimin; Feathers, David; Qin, Zhifeng; Xiao, Huajun; Xue, Lihao; Zhou, Qianxiang

    2015-03-01

    This study developed an ergonomic evaluation system for the design of high-altitude partial pressure suits (PPSs). A total of twenty-one Chinese males participated in the experiment which tested three types of ergonomics indices (manipulative mission, operational reach and operational strength) were studied using a three-dimensional video-based motion capture system, a target-pointing board, a hand dynamometer, and a step-tread apparatus. In total, 36 ergonomics indices were evaluated and optimized using regression and fitting analysis. Some indices that were found to be linearly related and redundant were removed from the study. An optimal ergonomics index system was established that can be used to conveniently and quickly evaluate the performance of different pressurized/non-pressurized suit designs. The resulting ergonomics index system will provide a theoretical basis and practical guidance for mission planners, suit designers and engineers to design equipment for human use, and to aid in assessing partial pressure suits. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. The Ratio of Partial Pressure Arterial Oxygen and Fraction of Inspired Oxygen 1 Day After Acute Respiratory Distress Syndrome Onset Can Predict the Outcomes of Involving Patients.

    Science.gov (United States)

    Lai, Chih-Cheng; Sung, Mei-I; Liu, Hsiao-Hua; Chen, Chin-Ming; Chiang, Shyh-Ren; Liu, Wei-Lun; Chao, Chien-Ming; Ho, Chung-Han; Weng, Shih-Feng; Hsing, Shu-Chen; Cheng, Kuo-Chen

    2016-04-01

    The initial hypoxemic level of acute respiratory distress syndrome (ARDS) defined according to Berlin definition might not be the optimal predictor for prognosis. We aimed to determine the predictive validity of the stabilized ratio of partial pressure arterial oxygen and fraction of inspired oxygen (PaO2/FiO2 ratio) following standard ventilator setting in the prognosis of patients with ARDS.This prospective observational study was conducted in a single tertiary medical center in Taiwan and compared the stabilized PaO2/FiO2 ratio (Day 1) following standard ventilator settings and the PaO2/FiO2 ratio on the day patients met ARDS Berlin criteria (Day 0). Patients admitted to intensive care units and in accordance with the Berlin criteria for ARDS were collected between December 1, 2012 and May 31, 2015. Main outcome was 28-day mortality. Arterial blood gas and ventilator setting on Days 0 and 1 were obtained.A total of 238 patients met the Berlin criteria for ARDS were enrolled, and they were classified as mild (n = 50), moderate (n = 125), and severe (n = 63) ARDS, respectively. Twelve (5%) patients who originally were classified as ARDS did not continually meet the Berlin definition, and a total of 134 (56%) patients had the changes regarding the severity of ARDS from Day 0 to Day 1. The 28-day mortality rate was 49.1%, and multivariate analysis identified age, PaO2/FiO2 on Day 1, number of organ failures, and positive fluid balance within 5 days as significant risk factors of death. Moreover, the area under receiver-operating curve for mortality prediction using PaO2/FiO2 on Day 1 was significant higher than that on Day 0 (P = 0.016).PaO2/FiO2 ratio on Day 1 after applying mechanical ventilator is a better predictor of outcomes in patients with ARDS than those on Day 0.

  9. Threshold value of home pulse pressure predicting arterial stiffness in patients with type 2 diabetes: KAMOGAWA-HBP study.

    Science.gov (United States)

    Kitagawa, Noriyuki; Ushigome, Emi; Matsumoto, Shinobu; Oyabu, Chikako; Ushigome, Hidetaka; Yokota, Isao; Asano, Mai; Tanaka, Muhei; Yamazaki, Masahiro; Fukui, Michiaki

    2018-03-01

    This cross-sectional multicenter study was designed to evaluate the threshold value of home pulse pressure (PP) and home systolic blood pressure (SBP) predicting the arterial stiffness in 876 patients with type 2 diabetes. We measured the area under the receiver-operating characteristic curve (AUC) and estimated the ability of home PP to identify arterial stiffness using Youden-Index defined cut-off point. The arterial stiffness was measured using the brachial-ankle pulse wave velocity (baPWV). AUC for arterial stiffness in morning PP was significantly greater than that in morning SBP (P AUC for arterial stiffness in evening PP was also significantly greater than that in evening SBP (P < .001). The optimal cut-off points for morning PP and evening PP, which predicted arterial stiffness, were 54.6 and 56.9 mm Hg, respectively. Our findings indicate that we should pay more attention to increased home PP in patients with type 2 diabetes. ©2018 Wiley Periodicals, Inc.

  10. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  11. Body height and arterial pressure in seated and supine young males during +2 G centrifugation

    DEFF Research Database (Denmark)

    Arvedsen, Sine K.; Eiken, Ola; Kölegård, Roger

    2015-01-01

    by the use of a human centrifuge would increase mean arterial pressure (MAP) more in tall than in short males in the seated position. In short (162-171cm, n=8) and tall (194-203cm, n=10) healthy males (18-41yr), brachial arterial pressure, heart rate (HR) and cardiac output were measured during +2G...... centrifugation, while they were seated upright with the legs kept horizontal (+2Gz). In a separate experiment, the same measurements were done with the subjects supine (+2Gx). During +2Gz MAP increased in the short (22±2 mmHg, P 

  12. Growth responses of Neurospora crassa to increased partial pressures of the noble gases and nitrogen.

    Science.gov (United States)

    Buchheit, R G; Schreiner, H R; Doebbler, G F

    1966-02-01

    Buchheit, R. G. (Union Carbide Corp., Tonawanda, N.Y.), H. R. Schreiner, and G. F. Doebbler. Growth responses of Neurospora crassa to increased partial pressures of the noble gases and nitrogen. J. Bacteriol. 91:622-627. 1966.-Growth rate of the fungus Neurospora crassa depends in part on the nature of metabolically "inert gas" present in its environment. At high partial pressures, the noble gas elements (helium, neon, argon, krypton, and xenon) inhibit growth in the order: Xe > Kr> Ar > Ne > He. Nitrogen (N(2)) closely resembles He in inhibitory effectiveness. Partial pressures required for 50% inhibition of growth were: Xe (0.8 atm), Kr (1.6 atm), Ar (3.8 atm), Ne (35 atm), and He ( approximately 300 atm). With respect to inhibition of growth, the noble gases and N(2) differ qualitatively and quantitatively from the order of effectiveness found with other biological effects, i.e., narcosis, inhibition of insect development, depression of O(2)-dependent radiation sensitivity, and effects on tissue-slice glycolysis and respiration. Partial pressures giving 50% inhibition of N. crassa growth parallel various physical properties (i.e., solubilities, solubility ratios, etc.) of the noble gases. Linear correlation of 50% inhibition pressures to the polarizability and of the logarithm of pressure to the first and second ionization potentials suggests the involvement of weak intermolecular interactions or charge-transfer in the biological activity of the noble gases.

  13. In vivo near real time imaging of oxygen partial pressures in the glass catfish (Kryptopterus bichirris)

    DEFF Research Database (Denmark)

    Steffensen, John Fleng

    2012-01-01

    of the transparent glass catfish (Kryptopterus bichirris), it is possible to measure near realtime oxygen partial pressure in vivo. We used a commercially-available digital single-lens reflex camera mounted with an optical long pass filter (II = 490 nm) and excited the phosphorescent dye in the microspheres inside...... the fish with externally-mounted blue light emitting diodes (lip = 470 nm) to image the oxygen partial pressure. This method makes it possible to investigate oxygen partial pressures in the vascular system and different tissues of fish without having to insert any probes into the animal. After injection...

  14. Time required for partial pressure of arterial oxygen equilibration during mechanical ventilation after a step change in fractional inspired oxygen concentration.

    Science.gov (United States)

    Cakar, N; Tuŏrul, M; Demirarslan, A; Nahum, A; Adams, A; Akýncý, O; Esen, F; Telci, L

    2001-04-01

    To determine the time required for the partial pressure of arterial oxygen (PaO2) to reach equilibrium after a 0.20 increment or decrement in fractional inspired oxygen concentration (FIO2) during mechanical ventilation. A multi-disciplinary ICU in a university hospital. Twenty-five adult, non-COPD patients with stable blood gas values (PaO2/FIO2 > or = 180 on the day of the study) on pressure-controlled ventilation (PCV). Following a baseline PaO2 (PaO2b) measurement at FIO2 = 0.35, the FIO2 was increased to 0.55 for 30 min and then decreased to 0.35 without any other change in ventilatory parameters. Sequential blood gas measurements were performed at 3, 5, 7, 9, 11, 15, 20, 25 and 30 min in both periods. The PaO2 values measured at the 30th min after a step change in FIO2 (FIO2 = 0.55, PaO2[55] and FIO2 = 0.35, PaO2[35]) were accepted as representative of the equilibrium values for PaO2. Each patient's rise and fall in PaO2 over time, PaO2(t), were fitted to the following respective exponential equations: PaO2b + (PaO2[55]-PaO2b)(1-e-kt) and PaO2[55] + (PaO2[35]-PaO2[55])(e-kt) where "t" refers to time, PaO2[55] and PaO2[35] are the final PaO2 values obtained at a new FIO2 of 0.55 and 0.35, after a 0.20 increment and decrement in FIO2, respectively. Time constant "k" was determined by a non-linear fitting curve and 90% oxygenation times were defined as the time required to reach 90% of the final equilibrated PaO2 calculated by using the non-linear fitting curves. Time constant values for the rise and fall periods were 1.01 +/- 0.71 min-1, 0.69 +/- 0.42 min-1, respectively, and 90% oxygenation times for rises and falls in PaO2 periods were 4.2 +/- 4.1 min-1 and 5.5 +/- 4.8 min-1, respectively. There was no significant difference between the rise and fall periods for the two parameters (p > 0.05). We conclude that in stable patients ventilated with PCV, after a step change in FIO2 of 0.20, 5-10 min will be adequate for obtaining a blood gas sample to measure a Pa

  15. Syngas fermentation to biofuels: Effects of hydrogen partial pressure on hydrogenase efficiency

    International Nuclear Information System (INIS)

    Skidmore, Bradley E.; Baker, Ryan A.; Banjade, Dila R.; Bray, Jason M.; Tree, Douglas R.; Lewis, Randy S.

    2013-01-01

    Producing biofuels from gasified biomass (synthesis gas) via microbial fermentation is currently being pursued as one alternative in biofuels development. In synthesis gas fermentation, reducing equivalents from H 2 oxidation via hydrogenase is important towards directing more carbon towards product formation. In this work, kinetic studies of H 2 utilization via the Clostridium P11 hydrogenase enzyme were performed to determine the most appropriate model to predict hydrogenase activity as a function of H 2 partial pressure. An important aspect of this work included the proper analysis of electron acceptors used in the kinetic studies. The K H 2 model parameter governing the effect of H 2 partial pressure on activity was ∼30 kPa (absolute), independent of the type and concentration of electron acceptor. The K H 2 value indicates that H 2 partial pressures typically associated with syngas fermentation will result in compromised efficiency of the hydrogenase activity. -- Highlights: ► We model hydrogenase activity as a function of H 2 and electron acceptors. ► Model shows the H 2 kinetic parameter is independent of electron acceptor. ► Hydrogenase efficiency is compromised at H 2 levels observed in gasified biomass

  16. Association between temporal mean arterial pressure and brachial noninvasive blood pressure during shoulder surgery in the beach chair position during general anesthesia.

    Science.gov (United States)

    Triplet, Jacob J; Lonetta, Christopher M; Everding, Nathan G; Moor, Molly A; Levy, Jonathan C

    2015-01-01

    Estimation of cerebral perfusion pressure during elective shoulder surgery in the beach chair position is regularly performed by noninvasive brachial blood pressure (NIBP) measurements. The relationship between brachial mean arterial pressure and estimated temporal mean arterial pressure (eTMAP) is not well established and may vary with patient positioning. Establishing a ratio between eTMAP and NIBP at varying positions may provide a more accurate estimation of cerebral perfusion using noninvasive measurements. This prospective study included 57 patients undergoing elective shoulder surgery in the beach chair position. All patients received an interscalene block and general anesthesia. After the induction of general anesthesia, values for eTMAP and NIBP were recorded at 0°, 30°, and 70° of incline. A statistically significant, strong, and direct correlation between NIBP and eTMAP was found at 0° (r = 0.909, P ≤ .001), 30° (r = 0.874, P Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Three-dimensional renal CT angiography for guiding segmental renal artery clamping during laparoscopic partial nephrectomy

    International Nuclear Information System (INIS)

    Xu, Yi; Shao, Pengfei; Zhu, Xiaomei; Lv, Qiang; Liu, Wangyan; Xu, Hai; Zhu, Yinsu; Yang, Guangyu; Tang, Lijun; Yin, Changjun

    2013-01-01

    Aim: To evaluate the effectiveness of three-dimensional (3D) renal computed tomography angiography (CTA) in guiding segmental renal artery clamping during laparoscopic partial nephrectomy (LPN). Materials and methods: Forty-three patients with renal tumours undergoing renal CTA before LPN were retrospectively enrolled in this study. 3D arteriogram reconstructed images were created to identify the renal tumour-supplying arteries. The number and location of these targeted vessels were annotated on 3D images preoperatively and compared with the clamped vessels during LPN. The consistency between target vessels annotated at CTA and clamped arteries at LPN was compared both using a patient-based analysis and vessel-based analysis. The χ 2 test was applied to analyse the influence of tumour size, location, and growth pattern on the number of clamped segmental renal branches. Results: On patient-based analysis, the number of targeted vessels was consistent with the clamped vessels during LPN in 33 of 43 patients. On vessel-based analysis, 56 of 65 target vessels annotated at CTA were clamped during LPN. More segmental renal branches (p = 0.04) were clamped in patients with tumours of larger size. Tumour location and growth pattern had no association with the number of clamped segmental branches during LPN. Conclusion: High-quality CTA images and 3D reconstruction images can detect detailed information of tumour-supplying arteries to renal tumours. 3D renal CTA is an effective way to guide segmental renal artery clamping during LPN

  18. Effect of mechanical behaviour of the brachial artery on blood pressure measurement during both cuff inflation and cuff deflation.

    Science.gov (United States)

    Zheng, Dingchang; Pan, Fan; Murray, Alan

    2013-10-01

    The aim of this study was to investigate the effect of different mechanical behaviour of the brachial artery on blood pressure (BP) measurements during cuff inflation and deflation. BP measurements were taken from each of 40 participants, with three repeat sessions under three randomized cuff deflation/inflation conditions. Cuff pressure was linearly deflated and inflated at a standard rate of 2-3 mmHg/s and also linearly inflated at a fast rate of 5-6 mmHg/s. Manual auscultatory systolic and diastolic BPs, and pulse pressure (SBP, DBP, PP) were measured. Automated BPs were determined from digitally recorded cuff pressures by fitting a polynomial model to the oscillometric pulse amplitudes. The BPs from cuff deflation and inflation were then compared. Repeatable measurements between sessions and between the sequential order of inflation/deflation conditions (all P > 0.1) indicated stability of arterial mechanical behaviour with repeat measurements. Comparing BPs obtained by standard inflation with those from standard deflation, manual SBP was 2.6 mmHg lower (P deflation suggest different arterial mechanical behaviour between arterial opening and closing during BP measurement. We have shown that the mechanical behaviour of the brachial artery during BP measurement differs between cuff deflation and cuff inflation.

  19. Dependence of mitochondrial and cytosolic adenine nucleotides on oxygen partial pressure in isolated hepatocytes. Application of a new rapid high pressure filtration technique for fractionation.

    OpenAIRE

    Hummerich, H; de Groot, H; Noll, T; Soboll, S

    1988-01-01

    By using a new rapid high pressure filtration technique, mitochondrial and cytosolic ATP and ADP contents were determined in isolated hepatocytes at different oxygen partial pressures. At 670 mmHg, subcellular adenine nucleotide contents and ATP/ADP ratios were comparable with values obtained with the digitonin fractionation technique. However at lower oxygen partial pressure ADP appears to be rephosphorylated during digitonin fractionation whereas with high pressure filtration fractionation ...

  20. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...

  1. Anatomic partial nephrectomy: technique evolution.

    Science.gov (United States)

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  2. Value of duplex scanning compared with angiography and pressure measurement in the assessment of aortoiliac arterial lesions

    NARCIS (Netherlands)

    Legemate, D. A.; Teeuwen, C.; Hoeneveld, H.; Eikelboom, B. C.

    1991-01-01

    To detect haemodynamically significant lesions in the aortoiliac arteries, invasive tests such as angiography and intra-arterial pressure measurement (IAPM) are considered valuable diagnostic tools. The value of duplex scanning as a direct non-invasive examination technique was prospectively

  3. Pulmonary artery pulse pressure and wave reflection in chronic pulmonary thromboembolism and primary pulmonary hypertension.

    Science.gov (United States)

    Castelain, V; Hervé, P; Lecarpentier, Y; Duroux, P; Simonneau, G; Chemla, D

    2001-03-15

    The purpose of this time-domain study was to compare pulmonary artery (PA) pulse pressure and wave reflection in chronic pulmonary thromboembolism (CPTE) and primary pulmonary hypertension (PPH). Pulmonary artery pressure waveform analysis provides a simple and accurate estimation of right ventricular afterload in the time-domain. Chronic pulmonary thromboembolism and PPH are both responsible for severe pulmonary hypertension. Chronic pulmonary thromboembolism and PPH predominantly involve proximal and distal arteries, respectively, and may lead to differences in PA pressure waveform. High-fidelity PA pressure was recorded in 14 patients (7 men/7 women, 46 +/- 14 years) with CPTE (n = 7) and PPH (n = 7). We measured thermodilution cardiac output, mean PA pressure (MPAP), PA pulse pressure (PAPP = systolic - diastolic PAP) and normalized PAPP (nPAPP = PPAP/MPAP). Wave reflection was quantified by measuring Ti, that is, the time between pressure upstroke and the systolic inflection point (Pi), deltaP, that is, the systolic PAP minus Pi difference, and the augmentation index (deltaP/PPAP). At baseline, CPTE and PPH had similar cardiac index (2.4 +/- 0.4 vs. 2.5 +/- 0.5 l/min/m2), mean PAP (59 +/- 9 vs. 59 +/- 10 mm Hg), PPAP (57 +/- 13 vs. 53 +/- 13 mm Hg) and nPPAP (0.97 +/- 0.16 vs. 0.89 +/- 0.13). Chronic pulmonary thromboembolism had shorter Ti (90 +/- 17 vs. 126 +/- 16 ms, p PPAP (0.26 +/- 0.01 vs. 0.09 +/- 0.07, p < 0.01). Our study indicated that: 1) CPTE and PPH with severe pulmonary hypertension had similar PA pulse pressure, and 2) wave reflection is elevated in both groups, and CPTE had increased and anticipated wave reflection as compared with PPH, thus suggesting differences in the pulsatile component of right ventricular afterload.

  4. A prospective study of glomerular filtration rate and arterial blood pressure in insulin-dependent diabetics with diabetic nephropathy

    DEFF Research Database (Denmark)

    Parving, H H; Smidt, U M; Friisberg, B

    1981-01-01

    Glomerular filtration rate (GFR, single bolus 51Cr-EDTA technique), serum creatinine, proteinuria and arterial blood pressure have been measured prospectively in 14 young onset insulin-dependent diabetics selected by of persistent proteinuria (greater than 0.5 g/day) secondary to diabetic...... in arterial blood pressure to a hypertensive level is an early feature of diabetic nephropathy in young insulin-dependent diabetics....... and 112/mumol/l (NS), proteinuria increased from 1.8 to 3.3 g/day (p less than 0.001) and arterial blood pressure rose from 132/88 to 153/101 mmHg (p less than 0.001). Glomerular filtration rate decreased linearly with time (slope = -0.75, r = 0.99, p less than 0.001) by a mean of 0.75 ml/min/month (range...

  5. Machine Learning Techniques for Arterial Pressure Waveform Analysis

    Directory of Open Access Journals (Sweden)

    João Cardoso

    2013-05-01

    Full Text Available The Arterial Pressure Waveform (APW can provide essential information about arterial wall integrity and arterial stiffness. Most of APW analysis frameworks individually process each hemodynamic parameter and do not evaluate inter-dependencies in the overall pulse morphology. The key contribution of this work is the use of machine learning algorithms to deal with vectorized features extracted from APW. With this purpose, we follow a five-step evaluation methodology: (1 a custom-designed, non-invasive, electromechanical device was used in the data collection from 50 subjects; (2 the acquired position and amplitude of onset, Systolic Peak (SP, Point of Inflection (Pi and Dicrotic Wave (DW were used for the computation of some morphological attributes; (3 pre-processing work on the datasets was performed in order to reduce the number of input features and increase the model accuracy by selecting the most relevant ones; (4 classification of the dataset was carried out using four different machine learning algorithms: Random Forest, BayesNet (probabilistic, J48 (decision tree and RIPPER (rule-based induction; and (5 we evaluate the trained models, using the majority-voting system, comparatively to the respective calculated Augmentation Index (AIx. Classification algorithms have been proved to be efficient, in particular Random Forest has shown good accuracy (96.95% and high area under the curve (AUC of a Receiver Operating Characteristic (ROC curve (0.961. Finally, during validation tests, a correlation between high risk labels, retrieved from the multi-parametric approach, and positive AIx values was verified. This approach gives allowance for designing new hemodynamic morphology vectors and techniques for multiple APW analysis, thus improving the arterial pulse understanding, especially when compared to traditional single-parameter analysis, where the failure in one parameter measurement component, such as Pi, can jeopardize the whole evaluation.

  6. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure......Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  7. Iron Deficiency in COPD Associates with Increased Pulmonary Artery Pressure Estimated by Echocardiography

    DEFF Research Database (Denmark)

    Plesner, Louis L; Schoos, Mikkel M; Dalsgaard, Morten

    2017-01-01

    OBJECTIVES: Iron deficiency (ID) might augment chronic pulmonary hypertension in chronic obstructive pulmonary disease (COPD). This observational study investigates the association between ID and systolic pulmonary artery pressure estimated by echocardiography in non-anaemic COPD outpatients...

  8. Oxidation of C/SiC Composites at Reduced Oxygen Partial Pressures

    Science.gov (United States)

    Opila, Elizabeth J.; Serra, Jessica

    2009-01-01

    Carbon-fiber reinforced SiC (C/SiC) composites are proposed for leading edge applications of hypersonic vehicles due to the superior strength of carbon fibers at high temperatures (greater than 1500 C). However, the vulnerability of the carbon fibers in C/SiC to oxidation over a wide range of temperatures remains a problem. Previous oxidation studies of C/SiC have mainly been conducted in air or oxygen, so that the oxidation behavior of C/SiC at reduced oxygen partial pressures of the hypersonic flight regime are less well understood. In this study, both carbon fibers and C/SiC composites were oxidized over a wide range of temperatures and oxygen partial pressures to facilitate the understanding and modeling of C/SiC oxidation kinetics for hypersonic flight conditions.

  9. Fourier Analysis of Peripheral Blood Pressure and Flow in Intraoperative Assessment of Infrainguinal Arterial Reconstructions

    Directory of Open Access Journals (Sweden)

    Cheshmedzhiev Mihail V.

    2014-08-01

    Full Text Available AIM: To assess infrainguinal arterial reconstructions by intraoperative flowmetry under the distal anastomosis using a fast Fourier transformation; calculate and compare the amplitude ratios of peripheral arterial blood pressure and volume flow before and after drug-induced vasodilation of occluded bypass grafts and bypass grafts that have been patent at least for 1 year. To find what magnitude of the change of these ratios indicate a long-term patency of the bypass grafting. PATIENTS AND METHODS: We compared the results of the intraoperative flowmetry tests of 97 patients with infrainguinal arterial reconstructions. The patients were divided into two groups based on the graft status: the grafts in 49 patients were patent for at least a year, and 48 patients had failed bypass. We used a fast Fourier transform (FFT of the pressure and blood flow waves and compared the ratios of their amplitudes before and after administration of a vasodilator drug into the graft. Comparing the ratios obtained before and those after administration of the drug we quantified their change in each group and analysed them. RESULTS: After a drug-induced vasodilation, the blood pressure and flow amplitude ratios for the group with compromised reconstructions were less than 1.9 times smaller than those before drug infusion, while for the group with bypass grafts that had been functional for at least 12 months the ratios declined by more than 1.9≈2 times. CONCLUSION: The magnitude of the change of amplitude ratios of the peripheral pressure and volume flow after drug-induced vasodilation can be used to make an assessment of the bypass graft and the distal arterial segment.

  10. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  11. The mechanical properties of the systemic and pulmonary arteries of Python regius correlate with blood pressures.

    Science.gov (United States)

    van Soldt, Benjamin J; Danielsen, Carl Christian; Wang, Tobias

    2015-12-01

    Pythons are unique amongst snakes in having different pressures in the aortas and pulmonary arteries because of intraventricular pressure separation. In this study, we investigate whether this correlates with different blood vessel strength in the ball python Python regius. We excised segments from the left, right, and dorsal aortas, and from the two pulmonary arteries. These were subjected to tensile testing. We show that the aortic vessel wall is significantly stronger than the pulmonary artery wall in P. regius. Gross morphological characteristics (vessel wall thickness and correlated absolute amount of collagen content) are likely the most influential factors. Collagen fiber thickness and orientation are likely to have an effect, though the effect of collagen fiber type and cross-links between fibers will need further study. © 2015 Wiley Periodicals, Inc.

  12. Combined resistance and endurance exercise training improves arterial stiffness, blood pressure, and muscle strength in postmenopausal women.

    Science.gov (United States)

    Figueroa, Arturo; Park, Song Y; Seo, Dae Y; Sanchez-Gonzalez, Marcos A; Baek, Yeong H

    2011-09-01

    Menopause is associated with increased arterial stiffness and reduced muscle strength. Combined resistance (RE) and endurance (EE) exercise training can decrease brachial-ankle pulse wave velocity (baPWV), an index of arterial stiffness, in young men. We tested the hypothesis that combined circuit RE and EE training would improve baPWV, blood pressure (BP), and muscle strength in postmenopausal women. Twenty-four postmenopausal women (age 47-68 y) were randomly assigned to a "no exercise" control (n = 12) or to combined exercise training (EX; n = 12) group. The EX group performed concurrent circuit RE training followed by EE training at 60% of the predicted maximal heart rate (HR) 3 days per week. Brachial systolic BP, diastolic BP, mean arterial pressure, baPWV, HR, and dynamic and isometric muscle strength were measured before and after the 12-week study. Mean ± SE baPWV (-0.8 ± 0.2 meters/s), systolic BP (-6.0 ± 1.9 mm Hg), diastolic BP (-4.8 ± 1.7 mm Hg), HR (-4.0 ± 1.0 beats/min), and mean arterial pressure (-5.1 ± 1.6 mm Hg) decreased (P hypertension and frailty in postmenopausal women.

  13. SrRuO3 thin films grown on MgO substrates at different oxygen partial pressures

    KAUST Repository

    Zou, Bin

    2013-01-08

    A comprehensive study of SrRuO3 thin films growth on (001) MgO substrates by pulsed laser deposition in a wide oxygen pressure range from 10 to 300 mTorr was carried out. The experimental results showed a correlation between the lattice constants, resistivity, and oxygen partial pressures used. Ru deficiency detected only in films deposited at lower oxygen pressures (<50 mTorr), resulted in an elongation of the in-plane and out-of-plane lattice constants and an increase in the film resistivity. When deposited with oxygen partial pressure of 50 mTorr, SrRuO3 films had lattice parameters matching those of bulk SrRuO3 material and exhibited room temperature resistivity of 320 μΩ·cm. The resistivity of SrRuO 3/MgO films decreased with increasing oxygen partial pressure. Copyright © 2013 Materials Research Society.

  14. Arterial blood pressure changes in acute T. brucei infection of dogs ...

    African Journals Online (AJOL)

    The aim of this study is to find out the usefulness of serial arterial blood pressure measurements in predicting severity and outcome of acute Trypanosoma brucei infection in dogs. Twenty adult dogs of mixed sexes and aged between 2 and 5 years were used for this study. The dogs were of good cardiac health and were ...

  15. The role of central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference as a goal and prognosis of sepsis treatment.

    Science.gov (United States)

    Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon

    2016-12-01

    The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Growth of the microalgae Neochloris oleoabundans at high partial oxygen pressures and sub-saturating light intensity

    NARCIS (Netherlands)

    Sousa, C.A.; Winter, de L.; Janssen, M.G.J.; Vermue, M.H.; Wijffels, R.H.

    2012-01-01

    The effect of partial oxygen pressure on growth of Neochloris oleoabundans was studied at sub-saturating light intensity in a fully-controlled stirred tank photobioreactor. At the three partial oxygen pressures tested (PO2=0.24; 0.63; 0.84 bar), the specific growth rate was 1.38; 1.36 and 1.06

  17. Effect of beta-1-blocker, nebivolol, on central aortic pressure and arterial stiffness in patients with essential hypertension.

    Science.gov (United States)

    Soanker, Radhika; Naidu, M U R; Raju, Sree Bhushan; Prasad, A Krishna; Rao, T Ramesh Kumar

    2012-05-01

    Blood pressure (BP) reduction is the major determinant of benefit provided by antihypertensive treatment. Although different drugs reduce peripheral BP to some extent, there may be a significant difference in their effect on central BP reduction. It has been shown that beta-blockers are efficient in reducing peripheral, but not central BP. This study was done to assess the effect of beta-1-blocker, nebivolol, in patients with essential hypertension on central aortic pressures and arterial stiffness. In this single arm, open-labeled study, 13 patients were given nebivolol, 5 mg orally once daily for 15 days. Primary outcome was change in central aortic pressure, and other measures of efficacy included changes in brachial BP, augmentation index (AIx%), AIx%@75 HR, augmentation pressure (AP), heart rate (HR), and carotid femoral pulse wave velocity (PWVcf). Nebivolol 5 mg significantly reduced central aortic pressures [systolic BP, 131.5-111.6 mmHg; diastolic BP, 96.3-81.7 mmHg; Mean Arterial Pressure (MAP), 111.3-94.0 mmHg (all PPressure (PP), 35.2-29.7 mmHg (Plost to followup. Nebivolol 5 mg demonstrated antihypertensive efficacy in patients with essential hypertension by reducing not only peripheral brachial pressures, but also significantly reducing central aortic pressures, augmentation index, and carotid femoral pulse wave velocity, which is the marker of arterial stiffness.

  18. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure

    Science.gov (United States)

    Wain, Louise V; Verwoert, Germaine C; O’Reilly, Paul F; Shi, Gang; Johnson, Toby; Johnson, Andrew D; Bochud, Murielle; Rice, Kenneth M; Henneman, Peter; Smith, Albert V; Ehret, Georg B; Amin, Najaf; Larson, Martin G; Mooser, Vincent; Hadley, David; Dörr, Marcus; Bis, Joshua C; Aspelund, Thor; Esko, Tõnu; Janssens, A Cecile JW; Zhao, Jing Hua; Heath, Simon; Laan, Maris; Fu, Jingyuan; Pistis, Giorgio; Luan, Jian’an; Arora, Pankaj; Lucas, Gavin; Pirastu, Nicola; Pichler, Irene; Jackson, Anne U; Webster, Rebecca J; Zhang, Feng; Peden, John F; Schmidt, Helena; Tanaka, Toshiko; Campbell, Harry; Igl, Wilmar; Milaneschi, Yuri; Hotteng, Jouke-Jan; Vitart, Veronique; Chasman, Daniel I; Trompet, Stella; Bragg-Gresham, Jennifer L; Alizadeh, Behrooz Z; Chambers, John C; Guo, Xiuqing; Lehtimäki, Terho; Kühnel, Brigitte; Lopez, Lorna M; Polašek, Ozren; Boban, Mladen; Nelson, Christopher P; Morrison, Alanna C; Pihur, Vasyl; Ganesh, Santhi K; Hofman, Albert; Kundu, Suman; Mattace-Raso, Francesco US; Rivadeneira, Fernando; Sijbrands, Eric JG; Uitterlinden, Andre G; Hwang, Shih-Jen; Vasan, Ramachandran S; Wang, Thomas J; Bergmann, Sven; Vollenweider, Peter; Waeber, Gérard; Laitinen, Jaana; Pouta, Anneli; Zitting, Paavo; McArdle, Wendy L; Kroemer, Heyo K; Völker, Uwe; Völzke, Henry; Glazer, Nicole L; Taylor, Kent D; Harris, Tamara B; Alavere, Helene; Haller, Toomas; Keis, Aime; Tammesoo, Mari-Liis; Aulchenko, Yurii; Barroso, Inês; Khaw, Kay-Tee; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Eyheramendy, Susana; Org, Elin; Sõber, Siim; Lu, Xiaowen; Nolte, Ilja M; Penninx, Brenda W; Corre, Tanguy; Masciullo, Corrado; Sala, Cinzia; Groop, Leif; Voight, Benjamin F; Melander, Olle; O’Donnell, Christopher J; Salomaa, Veikko; d’Adamo, Adamo Pio; Fabretto, Antonella; Faletra, Flavio; Ulivi, Sheila; Del Greco, M Fabiola; Facheris, Maurizio; Collins, Francis S; Bergman, Richard N; Beilby, John P; Hung, Joseph; Musk, A William; Mangino, Massimo; Shin, So-Youn; Soranzo, Nicole; Watkins, Hugh; Goel, Anuj; Hamsten, Anders; Gider, Pierre; Loitfelder, Marisa; Zeginigg, Marion; Hernandez, Dena; Najjar, Samer S; Navarro, Pau; Wild, Sarah H; Corsi, Anna Maria; Singleton, Andrew; de Geus, Eco JC; Willemsen, Gonneke; Parker, Alex N; Rose, Lynda M; Buckley, Brendan; Stott, David; Orru, Marco; Uda, Manuela; van der Klauw, Melanie M; Zhang, Weihua; Li, Xinzhong; Scott, James; Chen, Yii-Der Ida; Burke, Gregory L; Kähönen, Mika; Viikari, Jorma; Döring, Angela; Meitinger, Thomas; Davies, Gail; Starr, John M; Emilsson, Valur; Plump, Andrew; Lindeman, Jan H; ’t Hoen, Peter AC; König, Inke R; Felix, Janine F; Clarke, Robert; Hopewell, Jemma C; Ongen, Halit; Breteler, Monique; Debette, Stéphanie; DeStefano, Anita L; Fornage, Myriam; Mitchell, Gary F; Smith, Nicholas L; Holm, Hilma; Stefansson, Kari; Thorleifsson, Gudmar; Thorsteinsdottir, Unnur; Samani, Nilesh J; Preuss, Michael; Rudan, Igor; Hayward, Caroline; Deary, Ian J; Wichmann, H-Erich; Raitakari, Olli T; Palmas, Walter; Kooner, Jaspal S; Stolk, Ronald P; Jukema, J Wouter; Wright, Alan F; Boomsma, Dorret I; Bandinelli, Stefania; Gyllensten, Ulf B; Wilson, James F; Ferrucci, Luigi; Schmidt, Reinhold; Farrall, Martin; Spector, Tim D; Palmer, Lyle J; Tuomilehto, Jaakko; Pfeufer, Arne; Gasparini, Paolo; Siscovick, David; Altshuler, David; Loos, Ruth JF; Toniolo, Daniela; Snieder, Harold; Gieger, Christian; Meneton, Pierre; Wareham, Nicholas J; Oostra, Ben A; Metspalu, Andres; Launer, Lenore; Rettig, Rainer; Strachan, David P; Beckmann, Jacques S; Witteman, Jacqueline CM; Erdmann, Jeanette; van Dijk, Ko Willems; Boerwinkle, Eric; Boehnke, Michael; Ridker, Paul M; Jarvelin, Marjo-Riitta; Chakravarti, Aravinda; Abecasis, Goncalo R; Gudnason, Vilmundur; Newton-Cheh, Christopher; Levy, Daniel; Munroe, Patricia B; Psaty, Bruce M; Caulfield, Mark J; Rao, Dabeeru C

    2012-01-01

    Numerous genetic loci influence systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans 1-3. We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N=74,064) and follow-up studies (N=48,607), we identified at genome-wide significance (P= 2.7×10-8 to P=2.3×10-13) four novel PP loci (at 4q12 near CHIC2/PDGFRAI, 7q22.3 near PIK3CG, 8q24.12 in NOV, 11q24.3 near ADAMTS-8), two novel MAP loci (3p21.31 in MAP4, 10q25.3 near ADRB1) and one locus associated with both traits (2q24.3 near FIGN) which has recently been associated with SBP in east Asians. For three of the novel PP signals, the estimated effect for SBP was opposite to that for DBP, in contrast to the majority of common SBP- and DBP-associated variants which show concordant effects on both traits. These findings indicate novel genetic mechanisms underlying blood pressure variation, including pathways that may differentially influence SBP and DBP. PMID:21909110

  19. Treatment of ischial pressure sores with both profunda femoris artery perforator flaps and muscle flaps.

    Science.gov (United States)

    Kim, Chae Min; Yun, In Sik; Lee, Dong Won; Lew, Dae Hyun; Rah, Dong Kyun; Lee, Won Jai

    2014-07-01

    Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. We retrospectively analyzed data from 14 patients (16 ischial sores) whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. All flaps survived the entire follow-up period. Seven patients (50%) had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years). The mean follow-up period was 27.9 months (range, 3-57 months). In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%), wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%), but resolved with conservative treatment. Among 16 cases, there was only one (6%) recurrence at 34 months. The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.

  20. Treatment of Ischial Pressure Sores with Both Profunda Femoris Artery Perforator Flaps and Muscle Flaps

    Directory of Open Access Journals (Sweden)

    Chae Min Kim

    2014-07-01

    Full Text Available Background Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. Methods We retrospectively analyzed data from 14 patients (16 ischial sores whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. Results All flaps survived the entire follow-up period. Seven patients (50% had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years. The mean follow-up period was 27.9 months (range, 3-57 months. In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%, wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%, but resolved with conservative treatment. Among 16 cases, there was only one (6% recurrence at 34 months. Conclusions The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.

  1. Roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction.

    Science.gov (United States)

    Liu, Jia-Ming; Shen, Jian-Xiong; Zhang, Jian-Guo; Zhao, Hong; Li, Shu-Gang; Zhao, Yu; Qiu, Giu-Xing

    2012-01-01

    It has been stated that preoperative pulmonary function tests are essential to assess the surgical risk in patients with scoliosis. Arterial blood gas tests have also been used to evaluate pulmonary function before scoliotic surgery. However, few studies have been reported. The aim of this study was to investigate the roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction. This study involved scoliotic patients with moderate or severe pulmonary dysfunction (forced vital capacity treatment between January 2002 and April 2010. A total of 73 scoliotic patients (23 males and 50 females) with moderate or severe pulmonary dysfunction were included. The average age of the patients was 16.53 years (ranged 10 - 44). The demographic distribution, medical records, and radiographs of all patients were collected. All patients received arterial blood gas tests and pulmonary function tests before surgery. The arterial blood gas tests included five parameters: partial pressure of arterial oxygen, partial pressure of arterial carbon dioxide, alveolar-arterial oxygen tension gradient, pH, and standard bases excess. The pulmonary function tests included three parameters: forced expiratory volume in 1 second ratio, forced vital capacity ratio, and peak expiratory flow ratio. All five parameters of the arterial blood gas tests were compared between the two groups with or without postoperative pulmonary complications by variance analysis. Similarly, all three parameters of the pulmonary function tests were compared. The average coronal Cobb angle before surgery was 97.42° (range, 50° - 180°). A total of 15 (20.5%) patients had postoperative pulmonary complications, including hypoxemia in 5 cases (33.3%), increased requirement for postoperative ventilatory support in 4 (26.7%), pneumonia in 2 (13.3%), atelectasis in 2 (13.3%), pneumothorax in 1 (6.7%), and hydrothorax in 1 (6.7%). No significant differences

  2. Epistaxis after partial middle turbinectomy: the role of sphenopalatine artery ligation.

    Science.gov (United States)

    Cassano, Michele; Cassano, Pasquale

    2012-01-01

    Extensive nasal polyposis could involve the middle turbinate inducing the surgeon to partially remove it. We initiated this retrospective study to evaluate the effect of a partial middle turbinectomy (PMT) on postoperative epistaxis and if sphenopalatine artery ligation (SPAL) could reduce the risk of bleeding in patients without nasal packing. Twenty-seven patients with extended bilateral nasal polyposis and submitted to primary functional endoscopic sinus surgery (FESS) with PMT on 40 sides were retrospectively selected. Postoperative bleeding and other complications were evaluated and compared with those of a control group of 27 patients who underwent FESS with middle turbinate preservation on 40 sides. The study group was furthermore divided into 2 groups according to the execution of SPAL. The incidence of postoperative bleeding of both groups and of the 2 parts of the study group was compared using the Fisher exact test. A SPAL was necessary to stop intraoperative bleeding in 21 (52.5%) sides of the study group patients and in 7 (17.5%) of the control group patients. After surgery, epistaxis occurred in 8 cases (20%) in the PMT group (1 submitted to SPAL) and in 2 (5%) of the control group. The comparison with the Fisher exact test confirmed the major tendency of postoperative bleeding in the study group and in those not submitted to SPAL (P < .05). Partial middle turbinectomy causes a higher incidence of postoperative bleeding in patients who are not packed during the FESS operation. The execution of SPAL greatly reduces this risk. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Blood Pressure Response to Main Renal Artery and Combined Main Renal Artery Plus Branch Renal Denervation in Patients With Resistant Hypertension.

    Science.gov (United States)

    Fengler, Karl; Ewen, Sebastian; Höllriegel, Robert; Rommel, Karl-Philipp; Kulenthiran, Saaraaken; Lauder, Lucas; Cremers, Bodo; Schuler, Gerhard; Linke, Axel; Böhm, Michael; Mahfoud, Felix; Lurz, Philipp

    2017-08-10

    Single-electrode ablation of the main renal artery for renal sympathetic denervation showed mixed blood pressure (BP)-lowering effects. Further improvement of the technique seems crucial to optimize effectiveness of the procedure. Because sympathetic nerve fibers are closer to the lumen in the distal part of the renal artery, treatment of the distal main artery and its branches has been shown to reduce variability in treatment effects in preclinical studies and a recent randomized trial. Whether this optimized technique improves clinical outcomes remains uncertain. We report a 2-center experience of main renal artery and combined main renal artery plus branches renal denervation in patients with resistant hypertension using a multielectrode catheter. Twenty-five patients with therapy-resistant hypertension underwent renal sympathetic denervation with combined main renal artery and renal branch ablation and were compared to matched controls undergoing an ablation of the main renal artery only. BP change was assessed by ambulatory measurement at baseline and after 3 months. At baseline, BP was balanced between the groups. After 3 months, BP changed significantly in the combined ablation group (systolic/diastolic 24-hour mean and daytime mean BP -8.5±9.8/-7.0±10.7 and -9.4±9.8/-7.1±13.5 mm Hg, P renal artery and branches appears to improve BP-lowering efficacy and should be further investigated. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  4. Physiological Mechanisms Mediating the Coupling between Heart Period and Arterial Pressure in Response to Postural Changes in Humans

    NARCIS (Netherlands)

    Silvani, A.; Calandra-Buonaura, G.; Johnson, B.D.; Helmond, N. van; Barletta, G.; Cecere, A.G.; Joyner, M.J.; Cortelli, P.

    2017-01-01

    The upright posture strengthens the coupling between heart period (HP) and systolic arterial pressure (SAP) consistently with a greater contribution of the arterial baroreflex to cardiac control, while paradoxically decreasing cardiac baroreflex sensitivity (cBRS). To investigate the physiological

  5. [Effect of oxygen tubing connection site on percutaneous oxygen partial pressure and percutaneous carbon dioxide partial pressure in patients with chronic obstructive pulmonary disease during noninvasive positive pressure ventilation].

    Science.gov (United States)

    Mi, S; Zhang, L M

    2017-04-12

    Objective: We evaluated the effects of administering oxygen through nasal catheters inside the mask or through the mask on percutaneous oxygen partial pressure (PcO(2))and percutaneous carbon dioxide partial pressure (PcCO(2)) during noninvasive positive pressure ventilation (NPPV) to find a better way of administering oxygen, which could increase PcO(2) by increasing the inspired oxygen concentration. Methods: Ten healthy volunteers and 9 patients with chronic obstructive pulmonary disease complicated by type Ⅱ respiratory failure were included in this study. Oxygen was administered through a nasal catheter inside the mask or through the mask (oxygen flow was 3 and 5 L/min) during NPPV. PcO(2) and PcCO(2) were measured to evaluate the effects of administering oxygen through a nasal catheter inside the mask or through the mask, indirectly reflecting the effects of administering oxygen through nasal catheter inside the mask or through the mask on inspired oxygen concentration. Results: Compared to administering oxygen through the mask during NPPV, elevated PcO(2) was measured in administering oxygen through the nasal catheter inside the mask, and the differences were statistically significant ( P 0.05). Conclusion: Administering oxygen through a nasal catheter inside the mask during NPPV increased PcO(2) by increasing the inspired oxygen concentration but did not increase PcCO(2). This method of administering oxygen could conserve oxygen and be suitable for family NPPV. Our results also provided theoretical basis for the development of new masks.

  6. Inferior gluteal artery perforator flap: a viable alternative for ischial pressure sores.

    Science.gov (United States)

    Kim, Young Seok; Lew, Dae Hyun; Roh, Tai Suk; Yoo, Won Min; Lee, Won Jai; Tark, Kwan Chul

    2009-10-01

    The ischial area is by far the most common site for pressure sores in wheelchair-bound paraplegic patients, because most of the pressure of the body is exerted on this area in the seated position. Even after a series of successful pressure sore treatments, the site is very prone to relapse from the simplest everyday tasks. Therefore, it is crucial to preserve the main pedicle during primary surgery. Several surgical procedures, such as myocutaneous flap and perforator flap, have been introduced for the treatment of pressure sores. During a 4-year time period at our institute, we found favourable clinical results using the inferior gluteal artery perforator (IGAP) procedure for ischial sore treatment. A total of 23 patients (20 males and three females) received IGAP flap surgery in our hospital from January 2003 to January 2007. Surgery was performed on the same site again in 10 (43%) patients who had originally relapsed after undergoing the conventional method of pressure sore surgery. The average age of patients was 47.4 years (range 26-71 years). Most of the patients were paraplegic (16 cases, 70%) and others were either quadriplegic (four cases, 17%) or ambulatory (three cases, 13%). Based on hospital records and clinical photographs, we attempted to assess the feasibility and practicability of the IGAP flap procedure through comparative analysis of several parameters including the size of the defective area, treatment modalities, relapses, complications, and postoperative treatments. The average follow-up duration for 23 subjects was 25.4 months (range 5-42 months). All flaps survived without major complications. Partial flap necrosis developed in one case but secondary healing was achieved and the final outcome was not impaired. Most of the cases healed well during the follow-up period. Postoperative complications such as wound dehiscence and fistula developed in some subjects, but all healed well with a secondary treatment. A total of five cases relapsed

  7. Relations between a novel, reliable, and rapid index of arterial compliance (PP-HDI) and well-established inidices of arterial blood pressure (ABP) in a sample of hypertensive elderly subjects.

    Science.gov (United States)

    Bergamini, L; Finelli, M E; Bendini, C; Ferrari, E; Veschi, M; Neviani, F; Manni, B; Pelosi, A; Rioli, G; Neri, M

    2009-01-01

    Hypertension is a risk factor for a long-lasting arterial wall-remodelling leading to stiffness. The rapid method measuring the pulse pressure (PP) by means of the tool of Hypertension Diagnostic Instruments (HDI) called PP-HDI, overcomes some of the problems arising with more-time consuming methods, like ambulatory blood pressure monitoring (ABPM), and give information about the elasticity of the arterial walls. We studied the relationship between the PP-HDI, the large artery compliance (LA-C) and small artery compliance (SA-C) and few well-established indices of arterial blood pressure (ABP) in a sample of 75 hypertensive subjects, aged 65 years and over. Significant correlations between LA-C and heart rate (HR), PP-ABPM and PP-HDI were found. SA-C relates with HR and systolic blood pressure (SBP) measured in lying and standing positions. Applying a stepwise regression analysis, we found that LA-C variance stems from PP-HDI and HR, while SA-C variance stems from SBP in lying position. Receiver operator characteristic (ROC) curves for thresholds of PP showed that PP-HDI reached levels of sensitivity/specificity similar to PP-ABPM. In conclusion, surveillance of ABP through hemo-dynamic indices, in particular of SBP, is essential, nevertheless the advantage of this control is not known in an elderly population where the organ damage is already evident. PP needs necessarily an instrumental measurement. The PP-HDI result is similar in reliability with respect to PPABPM, but is more rapid and well applicable in an elderly population.

  8. A computational analysis of the long-term regulation of arterial pressure [v1; ref status: indexed, http://f1000r.es/1xq

    Directory of Open Access Journals (Sweden)

    Daniel A. Beard

    2013-10-01

    Full Text Available The asserted dominant role of the kidneys in the chronic regulation of blood pressure and in the etiology of hypertension has been debated since the 1970s. At the center of the theory is the observation that the acute relationships between arterial pressure and urine production—the acute pressure-diuresis and pressure-natriuresis curves—physiologically adapt to perturbations in pressure and/or changes in the rate of salt and volume intake. These adaptations, modulated by various interacting neurohumoral mechanisms, result in chronic relationships between water and salt excretion and pressure that are much steeper than the acute relationships. While the view that renal function is the dominant controller of arterial pressure has been supported by computer models of the cardiovascular system known as the “Guyton-Coleman model”, no unambiguous description of a computer model capturing chronic adaptation of acute renal function in blood pressure control has been presented. Here, such a model is developed with the goals of: 1. capturing the relevant mechanisms in an identifiable mathematical model; 2. identifying model parameters using appropriate data; 3. validating model predictions in comparison to data; and 4. probing hypotheses regarding the long-term control of arterial pressure and the etiology of primary hypertension. The developed model reveals: long-term control of arterial blood pressure is primarily through the baroreflex arc and the renin-angiotensin system; and arterial stiffening provides a sufficient explanation for the etiology of primary hypertension associated with ageing. Furthermore, the model provides the first consistent explanation of the physiological response to chronic stimulation of the baroreflex.

  9. Secondhand tobacco smoke, arterial stiffness, and altered circadian blood pressure patterns are associated with lung inflammation and oxidative stress in rats.

    Science.gov (United States)

    Gentner, Nicole J; Weber, Lynn P

    2012-02-01

    Chronic smoking and secondhand tobacco smoke exposure are major risk factors for cardiovascular disease that are known to adversely alter the structural and mechanical properties of arteries. The objective of this study was to determine the effects of subchronic secondhand tobacco smoke exposure on circadian blood pressure patterns, arterial stiffness, and possible sources of oxidative stress in conscious, unsedated radiotelemetry-implanted rats. Pulse wave change in pressure over time (dP/dt) was used an indicator of arterial stiffness and was compared with both structural (wall thickness) and functional (nitric oxide production and bioactivity and endothelin-1 levels) features of the arterial wall. In addition, histology of lung, heart, and liver was examined as well as pulmonary and hepatic detoxifying enzyme activity (cytochrome P450, specifically CYP1A1). Subchronic secondhand tobacco smoke exposure altered the circadian pattern of heart rate and blood pressure, with a loss in the normal dipping pattern of blood pressure during sleep. Secondhand tobacco smoke exposure also increased pulse wave dP/dt in the absence of any structural modifications in the arterial wall. Furthermore, although nitric oxide production and endothelin-1 levels were not altered by secondhand tobacco smoke, there was increased inactivation of nitric oxide as indicated by peroxynitrite production. Increased lung neutrophils or pulmonary CYP1A1 may be responsible for the increase in oxidative stress in rats exposed to secondhand tobacco smoke. In turn, this may be related to the observed failure of blood pressure to dip during periods of sleep and a possible increase in arterial stiffness.

  10. Investigating complex patterns of blocked intestinal artery blood pressure signals by empirical mode decomposition and linguistic analysis

    International Nuclear Information System (INIS)

    Yeh, J-R; Lin, T-Y; Shieh, J-S; Chen, Y; Huang, N E; Wu, Z; Peng, C-K

    2008-01-01

    In this investigation, surgical operations of blocked intestinal artery have been conducted on pigs to simulate the condition of acute mesenteric arterial occlusion. The empirical mode decomposition method and the algorithm of linguistic analysis were applied to verify the blood pressure signals in simulated situation. We assumed that there was some information hidden in the high-frequency part of the blood pressure signal when an intestinal artery is blocked. The empirical mode decomposition method (EMD) has been applied to decompose the intrinsic mode functions (IMF) from a complex time series. But, the end effects and phenomenon of intermittence damage the consistence of each IMF. Thus, we proposed the complementary ensemble empirical mode decomposition method (CEEMD) to solve the problems of end effects and the phenomenon of intermittence. The main wave of blood pressure signals can be reconstructed by the main components, identified by Monte Carlo verification, and removed from the original signal to derive a riding wave. Furthermore, the concept of linguistic analysis was applied to design the blocking index to verify the pattern of riding wave of blood pressure using the measurements of dissimilarity. Blocking index works well to identify the situation in which the sampled time series of blood pressure signal was recorded. Here, these two totally different algorithms are successfully integrated and the existence of the existence of information hidden in high-frequency part of blood pressure signal has been proven

  11. Investigating complex patterns of blocked intestinal artery blood pressure signals by empirical mode decomposition and linguistic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, J-R; Lin, T-Y; Shieh, J-S [Department of Mechanical Engineering, Yuan Ze University, 135 Far-East Road, Chung-Li, Taoyuan, Taiwan (China); Chen, Y [Far Eastern Memorial Hospital, Taiwan (China); Huang, N E [Research Center for Adaptive Data Analysis, National Central University, Taiwan (China); Wu, Z [Center for Ocean-Land-Atmosphere Studies (United States); Peng, C-K [Beth Israel Deaconess Medical Center, Harvard Medical School (United States)], E-mail: s939205@ mail.yzu.edu.tw

    2008-02-15

    In this investigation, surgical operations of blocked intestinal artery have been conducted on pigs to simulate the condition of acute mesenteric arterial occlusion. The empirical mode decomposition method and the algorithm of linguistic analysis were applied to verify the blood pressure signals in simulated situation. We assumed that there was some information hidden in the high-frequency part of the blood pressure signal when an intestinal artery is blocked. The empirical mode decomposition method (EMD) has been applied to decompose the intrinsic mode functions (IMF) from a complex time series. But, the end effects and phenomenon of intermittence damage the consistence of each IMF. Thus, we proposed the complementary ensemble empirical mode decomposition method (CEEMD) to solve the problems of end effects and the phenomenon of intermittence. The main wave of blood pressure signals can be reconstructed by the main components, identified by Monte Carlo verification, and removed from the original signal to derive a riding wave. Furthermore, the concept of linguistic analysis was applied to design the blocking index to verify the pattern of riding wave of blood pressure using the measurements of dissimilarity. Blocking index works well to identify the situation in which the sampled time series of blood pressure signal was recorded. Here, these two totally different algorithms are successfully integrated and the existence of the existence of information hidden in high-frequency part of blood pressure signal has been proven.

  12. Ischemic preconditioning of the lower extremity attenuates the normal hypoxic increase in pulmonary artery systolic pressure.

    Science.gov (United States)

    Foster, Gary P; Westerdahl, Daniel E; Foster, Laura A; Hsu, Jeffrey V; Anholm, James D

    2011-12-15

    Ischemic pre-condition of an extremity (IPC) induces effects on local and remote tissues that are protective against ischemic injury. To test the effects of IPC on the normal hypoxic increase in pulmonary pressures and exercise performance, 8 amateur cyclists were evaluated under normoxia and hypoxia (13% F(I)O(2)) in a randomized cross-over trial. IPC was induced using an arterial occlusive cuff to one thigh for 5 min followed by deflation for 5 min for 4 cycles. In the control condition, the resting pulmonary artery systolic pressure (PASP) increased from a normoxic value of 25.6±2.3 mmHg to 41.8±7.2 mmHg following 90 min of hypoxia. In the IPC condition, the PASP increased to only 32.4±3.1 mmHg following hypoxia, representing a 72.8% attenuation (p=0.003). No significant difference was detected in cycle ergometer time trial duration between control and IPC conditions with either normoxia or hypoxia. IPC administered prior to hypoxic exposure was associated with profound attenuation of the normal hypoxic increase of pulmonary artery systolic pressure. Published by Elsevier B.V.

  13. Effect of oxygen partial pressure on oxidation of Mo-metal

    Science.gov (United States)

    Sharma, Rabindar Kumar; Kumar, Prabhat; Singh, Megha; Gopal, Pawar; Reddy, G. B.

    2018-05-01

    This report explains the effect of oxygen partial pressure (PO2 ) on oxidation of Mo-metal in oxygen plasma. XRD results indulge that oxide layers formed on Mo-surfaces at different oxygen partial pressures have two different oxide phases (i.e. orthorhombic MoO3 and monoclinic Mo8O23). Intense XRD peaks at high pressure (i.e. 2.0×10-1 Torr) points out the formation of thick oxide layer on Mo-surface due to presence of large oxygen species in chamber and less oxide volatilization. Whereas, at low PO2 (6.5×10-2 and 7.5×10-2 Torr.) the reduced peak strength is owing to high oxide volatilization rate. SEM micrographs and thickness measurements also support XRD results and confirm that the optimum -2value of PO2 to deposited thicker and uniform oxide film on glass substrate is 7.5×10-2 Torr through plasma assistedoxidation process. Further to study the compositional properties, EDX of the sample M2 (the best sample) is carried out, which confirms that the stoichiometric ratio is less than 3 (i.e. 2.88). Less stoichiometric ratio again confirms the presence of sub oxides in oxide layers on Mo metal as evidenced by XRD results. All the observed results are well in consonance with each other.

  14. Growth of the microalgae Neochloris oleoabundans at high partial oxygen pressures and sub-saturating light intensity.

    Science.gov (United States)

    Sousa, Cláudia; de Winter, Lenneke; Janssen, Marcel; Vermuë, Marian H; Wijffels, René H

    2012-01-01

    The effect of partial oxygen pressure on growth of Neochloris oleoabundans was studied at sub-saturating light intensity in a fully-controlled stirred tank photobioreactor. At the three partial oxygen pressures tested (P(O)₂= 0.24; 0.63; 0.84 bar), the specific growth rate was 1.38; 1.36 and 1.06 day(-1), respectively. An increase of the P(CO)₂from 0.007 to 0.02 bar at P(O₂) of 0.84 bar resulted in an increase in the growth rate from 1.06 to 1.36 day(-1). These results confirm that the reduction of algal growth at high oxygen concentrations at sub-saturating light conditions is mainly caused by competitive inhibition of Rubisco. This negative effect on growth can be overcome by restoring the O(2)/CO(2) ratio by an increase in the partial carbon dioxide pressure. In comparison to general practice (P(O(2)) = 0.42 bar), working at partial O(2) pressure of 0.84 bar could reduce the energy requirement for degassing by a factor of 3-4. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Morning pressor surge, blood pressure variability, and arterial stiffness in essential hypertension.

    Science.gov (United States)

    Pucci, Giacomo; Battista, Francesca; Anastasio, Fabio; Schillaci, Giuseppe

    2017-02-01

    An excess morning blood pressure surge (MBPS) may portend an increased cardiovascular risk, but the mechanisms thereof have been little investigated. The link between MBPS, short-term blood pressure (BP) variability, and arterial stiffness has not been entirely defined. In 602 consecutive untreated hypertensive patients (48 ± 12 years, 61% men, office BP 149/93 ± 17/10 mmHg), we measured carotid-femoral pulse wave velocity (cf-PWV, SphygmoCor) and 24-h ambulatory BP. Using self-reported sleep and wake times, MBPS was defined as sleep-trough (ST-MBPS), prewaking, rising. Short-term BP variability was calculated as weighted 24-h SBP SD and average real variability of 24-h SBP (ARV), that is, average of absolute differences between consecutive SBP readings. ST-MBPS (r = 0.16, P < 0.001) and rising MBPS (r = 0.12, P = 0.003) showed a direct correlation with cf-PWV, whereas prewaking MBPS had no such relation (r = 0.06, P = 0.14). Only ST-MBPS was independently associated with cf-PWV (t = 1.96, P = 0.04) after adjustment for age, sex, height, office mean arterial pressure, heart rate, and renal function. This association was lost after further adjustment for weighted 24-h SBP SD (P = 0.13) or ARV (P = 0.24). ARV was a significant mediator of the relationship between ST-MBPS and cf-PWV (P = 0.003). In untreated hypertension, ST-MBPS has a direct relation with aortic stiffness, which is mediated by an increased ARV. The adverse effects of MBPS may be partly explained by its link with arterial stiffness, mediated by short-term SBP variability.

  16. Negative pressure wound therapy for partial-thickness burns.

    Science.gov (United States)

    Dumville, Jo C; Munson, Christopher; Christie, Janice

    2014-12-15

    A burn wound is a complex and evolving injury, with both local and systemic consequences. Burn treatments include a variety of dressings, as well as newer strategies, such as negative pressure wound therapy (NPWT), which, by means of a suction force that drains excess fluids from the burn, tries to promote the wound healing process and minimise progression of the burn wound. To assess the effectiveness of NPWT for people with partial-thickness burns. We searched the Cochrane Wounds Group Specialised Register (searched 04 September 2014); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 8). All randomised controlled trials (RCTs) and controlled clinical trials (CCTs) that evaluated the safety and effectiveness of NPWT for partial-thickness burns. Two review authors used standardised forms, and extracted the data independently. We assessed each trial for risk of bias, and resolved differences by discussion. One RCT, that was an interim report, satisfied the inclusion criteria. We undertook a narrative synthesis of results, as the absence of data and poor reporting precluded us from carrying out any formal statistical analysis. The trial was at high risk of bias. There was not enough evidence available to permit any conclusions to be drawn regarding the use of NPWT for treatment of partial-thickness burn wounds.

  17. Avaliação de fatores de risco associados com elevação da pressão arterial em crianças Evaluation of risk factors associated with increased blood pressure in children

    Directory of Open Access Journals (Sweden)

    Frederico D Garcia

    2004-02-01

    Full Text Available OBJETIVOS: Identificar fatores associados a níveis elevados de pressão arterial em crianças. MÉTODOS: Estudo transversal da pressão arterial de 672 crianças entre 2 e 11 anos de idade em duas instituições de ensino de Belo Horizonte, entre setembro e dezembro de 2001. A pressão arterial foi mensurada seguindo os parâmetros estabelecidos pelo relatório do Update on the 1987 Task Force Report on High Blood Pressure in Children and Adolescents. As seguintes variáveis foram estudadas: idade, sexo, cor da pele, índice de qualidade de vida urbana, estatura e índice de massa corporal. Para a comparação das médias, foi utilizada a análise de variância, e para a comparação de proporções, o teste qui-quadrado. As variáveis associadas a níveis mais elevados de pressão arterial foram incluídas em análise de regressão linear múltipla. RESULTADOS: Na análise univariada, níveis mais elevados de pressão arterial sistólica e diastólica estiveram associados com crianças de cor branca, crianças da região com alto índice de qualidade de vida urbana e com elevado índice de massa corporal. Na análise multivariada, apenas o índice de massa corporal, o índice de qualidade de vida urbana e a estatura mantiveram-se associados com níveis elevados de pressão sistólica. Em relação aos níveis mais elevados de pressão arterial diastólica, apenas as variáveis índice de qualidade de vida urbana e idade foram mantidas no modelo após o ajustamento. CONCLUSÃO: O sobrepeso e a obesidade estiveram associados com níveis mais elevados de pressão arterial sistólica. Outros fatores, não identificados, foram parcialmente associados a níveis mais elevados de pressão arterial de crianças do estabelecimento privado do ensino.OBJECTIVE: To identify factors associated with increased arterial blood pressure in children. METHODS: In this cross-sectional study, arterial blood pressure was measured in 672 children between 2 and 11

  18. Influence of isoflurane on the diastolic pressure-flow relationship and critical occlusion pressure during arterial CABG surgery: a randomized controlled trial

    OpenAIRE

    Hinz, Jos?; Mansur, Ashham; Hanekop, Gerd G.; Weyland, Andreas; Popov, Aron F.; Schmitto, Jan D.; Gr?ne, Frank F. G.; Bauer, Martin; Kazmaier, Stephan

    2016-01-01

    The effects of isoflurane on the determinants of blood flow during Coronary Artery Bypass Graft (CABG) surgery are not completely understood. This study characterized the influence of isoflurane on the diastolic Pressure-Flow (P-F) relationship and Critical Occlusion Pressure (COP) during CABG surgery. Twenty patients undergoing CABG surgery were studied. Patients were assigned to an isoflurane or control group. Hemodynamic and flow measurements during CABG surgery were perf...

  19. PREDICTION OF BLOOD PATTERN IN S-SHAPED MODEL OF ARTERY UNDER NORMAL BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    Mohd Azrul Hisham Mohd Adib

    2013-06-01

    Full Text Available Athletes are susceptible to a wide variety of traumatic and non-traumatic vascular injuries to the lower limb. This paper aims to predict the three-dimensional flow pattern of blood through an S-shaped geometrical artery model. This model has created by using Fluid Structure Interaction (FSI software. The modeling of the geometrical S-shaped artery is suitable for understanding the pattern of blood flow under constant normal blood pressure. In this study, a numerical method is used that works on the assumption that the blood is incompressible and Newtonian; thus, a laminar type of flow can be considered. The authors have compared the results with a previous study with FSI validation simulation. The validation and verification of the simulation studies is performed by comparing the maximum velocity at t = 0.4 s, because at this time, the blood accelerates rapidly. In addition, the resulting blood flow at various times, under the same boundary conditions in the S-shaped geometrical artery model, is presented. The graph shows that velocity increases linearly with time. Thus, it can be concluded that the flow of blood increases with respect to the pressure inside the body.

  20. On the mechanisms of blunted nocturnal decline in arterial blood pressure in NIDDM patients with diabetic nephropathy

    DEFF Research Database (Denmark)

    Nielsen, Flemming Steen; Rossing, P; Bang, L E

    1995-01-01

    Nondiabetic hypertensive patients lacking the normal nocturnal decline in arterial blood pressure have enhanced cardiovascular complications. Since cardiovascular morbidity and mortality are increased in non-insulin-dependent diabetes mellitus (NIDDM), we performed a prospective cross......-sectional case-controlled study comparing the diurnal variation in arterial blood pressure, prevalence of dippers, cardiac autonomic nervous function (beat-to-beat variation during deep breathing), and extracellular fluid volume (51Cr-labeled EDTA) in 55 NIDDM patients with diabetic nephropathy (group 1), 55...... NIDDM patients with normoalbuminuria (group 2), and 22 nondiabetic control subjects (group 3). All antihypertensive treatments were withdrawn at least 2 weeks before the study. The nocturnal blood pressure reduction (daytime-to-nighttime)/daytime (mean +/- SE) was impaired in group 1 (6.6 +/- 1...

  1. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Abhay B. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Kalange, Ashok E. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Tuljaram Chaturchand College, Baramati 413 102 (India); Bodas, Dhananjay, E-mail: dhananjay.bodas@gmail.co [Center for Nanobio Sciences, Agharkar Research Institute, Pune 411 004 (India); Gangal, S.A. [Department of Electronic Science, University of Pune, Pune 411 007 (India)

    2010-04-15

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  2. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    International Nuclear Information System (INIS)

    Joshi, Abhay B.; Kalange, Ashok E.; Bodas, Dhananjay; Gangal, S.A.

    2010-01-01

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  3. C1-esterase inhibitor protects against early vein graft remodeling under arterial blood pressure.

    Science.gov (United States)

    Krijnen, Paul A J; Kupreishvili, Koba; de Vries, Margreet R; Schepers, Abbey; Stooker, Wim; Vonk, Alexander B A; Eijsman, Leon; Van Hinsbergh, Victor W M; Zeerleder, Sacha; Wouters, Diana; van Ham, Marieke; Quax, Paul H A; Niessen, Hans W M

    2012-01-01

    Arterial pressure induced vein graft injury can result in endothelial loss, accelerated atherosclerosis and vein graft failure. Inflammation, including complement activation, is assumed to play a pivotal role herein. Here, we analyzed the effects of C1-esterase inhibitor (C1inh) on early vein graft remodeling. Human saphenous vein graft segments (n=8) were perfused in vitro with autologous blood either supplemented or not with purified human C1inh at arterial pressure for 6h. The vein segments and perfusion blood were analyzed for cell damage and complement activation. In addition, the effect of purified C1inh on vein graft remodeling was analyzed in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. Application of C1inh in the in vitro perfusion model resulted in significantly higher blood levels and significantly more depositions of C1inh in the vein wall. This coincided with a significant reduction in endothelial loss and deposition of C3d and C4d in the vein wall, especially in the circular layer, compared to vein segments perfused without supplemented C1inh. Administration of purified C1inh significantly inhibited vein graft intimal thickening in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. C1inh significantly protects against early vein graft remodeling, including loss of endothelium and intimal thickening. These data suggest that it may be worth considering its use in patients undergoing coronary artery bypass grafting. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. [A comparative study between inflation and deflation pressure-volume curve in determining the optimal positive end-expiratory pressure].

    Science.gov (United States)

    Gang, Li; Sun, Xiao-yi; Xu, Jin-quan; Zhang, Xin-li; Kou, Lu-xin; Jiang, Zhi-hong; Zhang, Lei

    2012-02-01

    To determine the optimal positive end-expiratory pressure (PEEP) according to inflation and deflation pressure-volume curve (P-V curve) in patients with acute respiratory distress syndrome (ARDS). ARDS models were reproduced in 20 dogs, and they were randomly divided into two groups. In both groups, Levenberg-Marquardt iterative algorithm was employed using software to explore parameters fitting with Boltzmann formula, by which the real inflection point of pressure (Pinf d) in deflation limb or lower inflection point pressure (PLip) in inflation limb on P-V curve were defined. For the control group (inflation curve) P-V curve of PLip + 2 cm H(2)O [1 cm H(2)O = 0.098 kPa] was applied as the best PEEP value. In the experimental group (deflation curve) the Pinf d was taken as the best PEEP value. The heart rate (HR), blood pressure (BP), fingertip pulse oxygen saturation [SpO(2)], static lung compliance (Cst), arterial partial pressure of oxygen [PaO(2)] and arterial partial pressure of carbon dioxide [PaCO(2)] were monitored at 0, 2, 6, 12, 24 and 48 hours. Oxygenation index increased significantly both in control and experimental groups. In experimental group, oxygenation index (mm Hg, 1 mm Hg = 0.133 kPa) of 12, 24 and 48 hours was respectively significantly higher than that of the control group (12 hours: 177.63 ± 8.94 vs. 165.60 ± 8.90, 24 hours: 194.19 ± 10.67 vs. 168.70 ± 10.60, 48 hours: 203.15 ± 13.21 vs. 171.26 ± 9.21, all P deflation P-V curve was better than that of inflation curve.

  5. TUNABLE MAGNETIC AND ELECTRICAL PROPERTIES OF Co-DOPED ZnO FILMS BY VARYING OXYGEN PARTIAL PRESSURE

    OpenAIRE

    L. G. WANG; H. W. ZHANG; X. L. TANG; Y. X. LI; Z. Y. ZHONG

    2011-01-01

    High quality Co-doped ZnO films with good reproducibility have been prepared under different oxygen partial pressure by radio-frequency magnetron sputtering. These films were characterized using numerous characterization techniques including X-ray diffraction, electrical transport, and magnetization measurements. The effect of oxygen partial pressure on the structural, magnetic, and electrical properties of Co-doped ZnO films has been systematically studied. It was found that the structural, ...

  6. Echocardiographic assessment of systolic pulmonary arterial pressure in HIV-positive patients.

    Directory of Open Access Journals (Sweden)

    Mehrnaz Rasoulinejad

    2014-11-01

    Full Text Available Pulmonary hypertension is rare but is one of the complications that occur due to HIV infection. Symptoms of HIV-associated pulmonary arterial hypertension are often non-specific but the main symptom of the disease is dyspnea. In this cross-sectional study, we measured systolic pulmonary arterial pressure (SPAP by echocardiographic methods among HIV-positive patients who received ART. This research is a descriptive, cross-sectional study of 170 HIV-positive patients that was conducted in Imam-Khomeini hospital, Tehran, Iran during 2011-2013. All patients regularly received antiretroviral therapy at least for recent 2 years. There were not any cardiopulmonary symptoms (cough, dyspnea, exertional fatigue and chest discomfort in these patients. All participants underwent echocardiography to estimate SPAP. The participants comprised 108 males (63.5% and 62 females (46.5%. The mean age of patients was 41 years old, and the mean duration of HIV infection was 5.5 years. The mean CD4 cell count was 401 cell/µl. The principal regimen of antiretroviral therapy included two nucleoside reverse transcriptase inhibitor (NRTI and one non-nucleoside reverse transcriptase inhibitor (NNRTI in the hospital. The mean of systolic pulmonary arterial pressure was 25 mmHg in the participants; 156 (93.4% of them had SPAP ≤ 30 mmHg (normal, six (3.6% had SPAP: 31-35 mmHg (borderline and five (3% had SPAP > 35 mmHg (pulmonary hypertension. Our results indicated a significant increase of pulmonary hypertension in asymptomatic HIV-positive patients that had no association with any other risk factor. Also, antiretroviral therapy was not a risk factor for pulmonary hypertension in this study.

  7. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    Full Text Available Abstract Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min.

  8. Effects of various factors on Doppler ultrasonographic measurements of radial and coccygeal arterial blood pressure in privately owned, conscious cats.

    Science.gov (United States)

    Whittemore, Jacqueline C; Nystrom, Michael R; Mawby, Dianne I

    2017-04-01

    OBJECTIVE To assess the effects of age, body condition score (BCS), and muscle condition score (MCS) on radial and coccygeal systolic arterial blood pressure (SAP) in cats. DESIGN Prospective randomized trial. ANIMALS 66 privately owned cats enrolled between May and December 2010. PROCEDURES BCS and MCS of cats were assessed by 2 investigators; SAP was measured via Doppler ultrasonic flow detector, with cats positioned in right lateral or sternal recumbency for measurements at the radial or coccygeal artery, respectively, with order of site randomized. Associations among variables were assessed through correlation coefficients, partial correlation coefficients, and ANCOVA. RESULTS Interrater reliability for BCS and MCS assessment was high (correlation coefficients, 0.95 and 0.83, respectively). No significant effect was identified for order of SAP measurement sites. Coccygeal and radial SAP were positively correlated (ρ = 0.45). The median difference in coccygeal versus radial SAP was 19 mm Hg, but differences were not consistently positive or negative. Radial SAP was positively correlated with age (ρ = 0.48) and negatively correlated with MCS (ρ = -0.30). On the basis of the correlation analysis, the association between radial SAP and MCS reflected the confounding influence of age. Coccygeal SAP was not significantly correlated with age, BCS, or MCS. CONCLUSIONS AND CLINICAL RELEVANCE Use of the coccygeal artery is recommended to reduce the confounding effects of age and sarcopenia on Doppler ultrasonographic SAP measurements in cats. Additionally, monitoring for changes in MCS is recommended for cats undergoing serial SAP measurement.

  9. Chronic intersticial lung disease in the horse- Findings in arterial bloodgas analysis, tracheobronchial mucus cytology and radiological examination of the thorax; Chronisch interstitielle Lungenerkrankung beim Pferd - Blutgasanalytische, sekretzytolytische und röntgenologische Befunde

    Energy Technology Data Exchange (ETDEWEB)

    Dieckmann, M. [Klinik fuer Pferde, Tieraerztliche Hochschule Hannover (Germany); Klein, H. J.; Deegen, E.

    1990-07-01

    In 12 horses chronic interstitial lung disease was diagnosed. All horses were referrred because of unexplained loss of performance. In general there was no history of respiratory problems; 4 horses showed nasal discharge and 2 horses coughed. Results of arterial bloodgas analysis, tracheobronchial mucus cytology and radiological examination of the lungs were found in a typical combination, and they were different from results found generally in horses suffering from chronic obstructive pulmonary disease. Mean value of arterial partial pressure of oxygen was 100,6 mm Hg, arterial partial pressure of carbon dioxide was 45,1 mm Hg and alveolo-arterial difference in oxygen 5,1 mm Hg, respectively. In tracheobronchial aspirates pulmonary alveolar macrophages and neutrophil granulocytes were found in a relation of 2,6 : 1. Chest radiographs of all horses showed diffuse interstitial pattern throughout the lung.

  10. Evaluation of the cerebrovascular pressure reactivity index using non-invasive finapres arterial blood pressure

    International Nuclear Information System (INIS)

    Kasprowicz, M; Kim, D J; Haubrich, C; Czosnyka, Z; Smielewski, P; Czosnyka, M; Schmidt, E

    2010-01-01

    A pressure reactivity index (PRx) can be assessed in patients with continuous monitoring of arterial blood pressure (ABP) and intracranial pressure (ICP) as a moving correlation coefficient between slow fluctuations of these two signals within a low frequency bandwidth. The study aimed to investigate whether the invasive ABP monitoring can be replaced with non-invasive measurement of ABP using a Finapres plethysmograph (fABP) to calculate the fPRx. There is a well-defined group of patients, suffering from hydrocephalus and undergoing CSF pressure monitoring, which may benefit from such a measurement. 41 simultaneous day-by-day monitoring of ICP, ABP and fABP were performed for about 30 min in 10 head injury patients. A Bland–Altman assessment for agreement was used to compare PRx and fPRx calculations. Performance metrics and the McNemary test were used to determine whether fPRx is sensitive enough to distinguish between functioning and disturbed cerebrovascular pressure reactivity. The fPRx correlated with PRx (R Spearman = 0.92, p < 0.001; bias = −0.04; lower and upper limits of agreement: −0.26 and 0.17, respectively). The fPRx distinguished between active and passive reactivity in more than 89% cases. The fPRx can be used with care for assessment of cerebrovascular reactivity in patients for whom invasive ABP measurement is not feasible. The fPRx is sensitive enough to distinguish between functional and deranged reactivity

  11. Negative-Pressure Hydrocephalus: A Case Report on Successful Treatment Under Intracranial Pressure Monitoring with Bilateral Ventriculoperitoneal Shunts.

    Science.gov (United States)

    Pandey, Sajan; Jin, Yi; Gao, Liang; Zhou, Cheng Cheng; Cui, Da Ming

    2017-03-01

    Negative-pressure hydrocephalus (NegPH), a very rare condition of unknown etiology and optimal treatment, usually presents postneurosurgery with clinical and imaging features of hydrocephalus, but with negative cerebrospinal fluid pressure. We describe a NegPH case of -3 mm Hg intracranial pressure that was successfully treated to achieve 5 mm Hg under continuous intracranial pressure monitoring with horizontal positioning, head down and legs elevated to 10°-15°, neck wrapping for controlled venous drainage, chest and abdomen bandages, infusion of 5% dextrose fluid to lower plasma osmolarity (Na + , 130-135 mmol/L), daily cerebrospinal fluid drainage >200 mL, and arterial blood gas partial pressure of carbon dioxide >40 mm Hg. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Effects of a nitrate-rich meal on arterial stiffness and blood pressure in healthy volunteers.

    Science.gov (United States)

    Liu, Alex H; Bondonno, Catherine P; Croft, Kevin D; Puddey, Ian B; Woodman, Richard J; Rich, Lisa; Ward, Natalie C; Vita, Joseph A; Hodgson, Jonathan M

    2013-11-30

    An increase in nitrate intake can augment circulating nitrite and nitric oxide. This may lead to lower blood pressure and improved vascular function. Green leafy vegetables, such as spinach, are rich sources of nitrate. We aimed to assess the acute effects of a nitrate-rich meal containing spinach on arterial stiffness and blood pressure in healthy men and women. Twenty-six participants aged 38-69years were recruited to a randomized controlled cross-over trial. The acute effects of two energy-matched (2000kJ) meals, administered in random order, were compared. The meals were either high nitrate (220mg of nitrate derived from spinach [spinach]) or low nitrate [control]. Outcome measurements were performed pre-meal and at specific time points up to 210min post meal. Spinach resulted in an eightfold increase in salivary nitrite and a sevenfold increase in salivary nitrate concentrations from pre-meal (Pnitrate-rich meal can lower systolic blood pressure and pulse pressure and increase large artery compliance acutely in healthy men and women. If sustained, these effects could contribute to better cardiovascular health. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Profunda Femoris Artery Perforator Propeller Flap: A Valid Method to Cover Complicated Ischiatic Pressure Sores.

    Science.gov (United States)

    Scalise, Alessandro; Tartaglione, Caterina; Bolletta, Elisa; Pierangeli, Marina; Di Benedetto, Giovanni

    2015-08-01

    We report the case of a 50-year-old paraplegic man with a complicated grade III/IV ischiatic pressure sore treated with a propeller flap based on the first perforator of the profunda femoris artery. Our aim was to surgically reconstruct an ischiatic pressure sore in a patient with ankylosis using a fasciocutaneous perforator propeller flap obtained from the posterior region of the thigh. Our decision to perform a profunda femoris artery perforator propeller flap reconstruction was mainly due to the anatomical contiguity of the flap with the site of the lesion and the good quality of the skin harvested from the posterior region of the thigh. The use of the perforator fasciocutaneous flap represents a muscle-sparing technique, providing a better long-term result in surgical reconstruction. The choice of the 180-degree propeller flap was due to its ability to provide a good repair of the pressure ulcer and to pass over the ischiatic prominence in the patient in the forced decubitus position. The operatory course did not present any kind of complication. Using this reconstructive treatment, we have obtained complete coverage of the ischiatic pressure sore.

  14. Trial occlusion to assess the risk of persistent pulmonary arterial hypertension after closure of a large patent ductus arteriosus in adolescents and adults with elevated pulmonary artery pressure.

    Science.gov (United States)

    Zhang, Duan-Zhen; Zhu, Xian-Yang; Lv, Bei; Cui, Chun-Sheng; Han, Xiu-Min; Sheng, Xiao-Tang; Wang, Qi-Guang; Zhang, Po

    2014-08-01

    No method is available to predict whether patients with patent ductus arteriosus (PDA) and severe pulmonary arterial hypertension (PAH) will show persistent postprocedural PAH (PP-PAH) after PDA closure. This study evaluated the usefulness of trial occlusion for predicting PP-PAH after transcatheter PDA closure in patients with severe PAH. Trial occlusion was performed in 137 patients (age ≥12 years) with PDA and severe PAH. All patients undergoing trial occlusion had a mean pulmonary artery pressure ≥45 mm Hg, pulmonary:systemic flow (Qp/Qs) ratio >1.5, and pulmonary:systemic resistance (Rp/Rs) ratio closure. Linear correlation analysis revealed weak or moderate relationships between the baseline and post-trial pulmonary artery pressures and pulmonary:systemic pressure (Pp/Ps) ratios. Patients were followed up for 1 to 10 years (median: 5 years). PP-PAH (systolic pulmonary artery pressure >50 mm Hg by Doppler echocardiography) was detected in 17 patients (13%), who displayed no significant differences in sex and age compared with patients without PP-PAH. According to discriminant analysis, the strongest discriminators between patients with and without PP-PAH were the baseline left ventricular end-diastolic volume and the baseline and post-trial systolic Pp/Ps ratios. In particular, a post-trial systolic Pp/Ps ratio >0.5 correctly classified 100% of the PP-PAH and non-PAH patients. Trial occlusion is a feasible method to predict PP-PAH in patients with PDA and severe PAH. A post-trial systolic Pp/Ps ratio >0.5 indicates a high risk of PP-PAH occurrence after device closure. © 2014 American Heart Association, Inc.

  15. Impact of arterial occlusion during partial nephrectomy on residual renal function. An evaluation with {sup 99m}technetium-dimercaptosuccinic acid scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Tsunenori; Nakazawa, Hayakazu; Ito, Fumio; Onitsuka, Shiro; Ryoji, Osamu; Yago, Rie; Hashimoto, Yasunobu; Toma, Hiroshi [Tokyo Women' s Medical Coll. (Japan)

    2002-08-01

    Partial nephrectomy (PNx) has been performed with temporary renal arterial occlusion and in situ renal hypothermia (conventional PNx). However, the impact of temporary renal arterial occlusion on residual renal function has not been well assessed. To address this question, we performed renal scintigraphy with {sup 99m}technetium-dimercaptosuccinic acid (DMSA) for the quantitative measurement of postoperative residual renal function after conventional PNx and partial nephrectomy without arterial occlusion (non-clamping PNx). Thirty-four patients underwent postoperative DMSA scintigraphy after PNx for renal cell carcinoma. No obvious difference in preoperative renal function between the diseased kidney and the contralateral kidney was found in any of the patients. Of these patients, 24 underwent conventional PNx, and 10 underwent non-clamping PNx. Residual renal function was evaluated using the relative DMSA uptake of the operated kidney. The relative DMSA uptake of the operated kidney was 39.9{+-}7.3% (25.1-58.8) after conventional PNx compared to 34.8{+-}8.9% (13.5-45.5) after non-clamping PNx. This difference was not statistically significant (P=0.15). Total ischemic time during conventional PNx had no adverse influence on the residual renal function. In the analysis of the other determinant factors influencing residual renal function, tumor size was the only significant factor that inversely correlated with the relative DMSA uptake. Our results showed that arterial clamping during PNx has no negative impact on the functional residual capacity as long as in situ renal hypothermia is adequately performed. (author)

  16. Oxygen Exposure Resulting in Arterial Oxygen Tensions Above the Protocol Goal Was Associated With Worse Clinical Outcomes in Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Aggarwal, Neil R; Brower, Roy G; Hager, David N; Thompson, B Taylor; Netzer, Giora; Shanholtz, Carl; Lagakos, Adrian; Checkley, William

    2018-04-01

    High fractions of inspired oxygen may augment lung damage to exacerbate lung injury in patients with acute respiratory distress syndrome. Participants enrolled in Acute Respiratory Distress Syndrome Network trials had a goal partial pressure of oxygen in arterial blood range of 55-80 mm Hg, yet the effect of oxygen exposure above this arterial oxygen tension range on clinical outcomes is unknown. We sought to determine if oxygen exposure that resulted in a partial pressure of oxygen in arterial blood above goal (> 80 mm Hg) was associated with worse outcomes in patients with acute respiratory distress syndrome. Longitudinal analysis of data collected in these trials. Ten clinical trials conducted at Acute Respiratory Distress Syndrome Network hospitals between 1996 and 2013. Critically ill patients with acute respiratory distress syndrome. None. We defined above goal oxygen exposure as the difference between the fraction of inspired oxygen and 0.5 whenever the fraction of inspired oxygen was above 0.5 and when the partial pressure of oxygen in arterial blood was above 80 mm Hg. We then summed above goal oxygen exposures in the first five days to calculate a cumulative above goal oxygen exposure. We determined the effect of a cumulative 5-day above goal oxygen exposure on mortality prior to discharge home at 90 days. Among 2,994 participants (mean age, 51.3 yr; 54% male) with a study-entry partial pressure of oxygen in arterial blood/fraction of inspired oxygen that met acute respiratory distress syndrome criteria, average cumulative above goal oxygen exposure was 0.24 fraction of inspired oxygen-days (interquartile range, 0-0.38). Participants with above goal oxygen exposure were more likely to die (adjusted interquartile range odds ratio, 1.20; 95% CI, 1.11-1.31) and have lower ventilator-free days (adjusted interquartile range mean difference of -0.83; 95% CI, -1.18 to -0.48) and lower hospital-free days (adjusted interquartile range mean difference of -1.38; 95

  17. Oxygen partial pressure dependence of electrical conductivity in γ'-Bi2MoO6

    International Nuclear Information System (INIS)

    Vera, C.M.C.; Aragon, R.

    2008-01-01

    The electrical conductivity of γ'-Bi 2 MoO 6 was surveyed between 450 and 750 deg. C as a function of oxygen partial pressure, in the range 0.01-1 atm. A -1/6 power law dependence, consistent with a Frenkel defect model of doubly ionized oxygen vacancies and interstitials, is evidence for an n-type semiconductive component, with an optical band gap of 2.9 eV. The absence of this dependence is used to map the onset of dominant ionic conduction. - Graphical abstract: Temporal dependence of electrical conductivity at 500 deg. C for γ'-Bi 2 MoO 6 at controlled partial pressures of oxygen

  18. Pressure passive cerebral blood flow and breakdown of the blood-brain barrier in experimental fetal asphyxia

    DEFF Research Database (Denmark)

    Lou, H C; Lassen, N A; Tweed, W A

    1979-01-01

    reaching CBF values up to 6 times normal at normal MABP of about 60 to 70 mmHg, and severe ischemia reaching CBF values close to zero in large cortical areas at MABP of 30 mmHg. CVP remained essentially unchanged at 10--15 mmHg. The severe and prolonged asphyxia rendered the blood-brain barrier leaky......Cerebral blood flow (CBF) was studied in non-exteriorized near-term sheep fetuses using the radioactive microsphere technique. By partially occluding the umbilical vessels for a period of 1--1 1/2 hours a progressive and severe asphyxia with a final arterial pH of 6.90 was achieved. Varying...... the mean arterial blood pressure in the fetuses by blood withdrawal or infusion in this state, CBF was measured at different perfusion pressures (mean arterial blood pressure (MABP) minus central venous pressure (CVP)). A passive flow/pressure relationship--loss of autoregulation--was found, with hyperemia...

  19. Application and analysis of retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping for patients with multiple renal tumor: initial experience.

    Science.gov (United States)

    Zhu, Jundong; Jiang, Fan; Li, Pu; Shao, Pengfei; Liang, Chao; Xu, Aiming; Miao, Chenkui; Qin, Chao; Wang, Zengjun; Yin, Changjun

    2017-09-11

    To explore the feasibility and safety of retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping for the patients with multiple renal tumor of who have solitary kidney or contralateral kidney insufficiency. Nine patients who have undergone retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping between October 2010 and January 2017 were retrospectively analyzed. Clinical materials and parameters during and after the operation were summarized. Nineteen tumors were resected in nine patients and the operations were all successful. The operation time ranged from 100 to 180 min (125 min); clamping time of segmental renal artery was 10 ~ 30 min (23 min); the amount of blood loss during the operation was 120 ~ 330 ml (190 ml); hospital stay after the operation is 3 ~ 6d (5d). There was no complication during the perioperative period, and the pathology diagnosis after the surgery showed that there were 13 renal clear cell carcinomas, two papillary carcinoma and four perivascular epithelioid cell tumors with negative margins from the 19 tumors. All patients were followed up for 3 ~ 60 months, and no local recurrence or metastasis was detected. At 3-month post-operation follow-up, the mean serum creatinine was 148.6 ± 28.1 μmol/L (p = 0.107), an increase of 3.0 μmol/L from preoperative baseline. For the patients with multiple renal tumors and solitary kidney or contralateral kidney insufficiency, retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping was feasible and safe, which minimized the warm ischemia injury to the kidney and preserved the renal function effectively.

  20. Treatment of a partially thrombosed giant aneurysm of the vertebral artery by aneurysm trapping and direct vertebral artery-posterior inferior cerebellar artery end-to-end anastomosis: technical case report.

    Science.gov (United States)

    Benes, Ludwig; Kappus, Christoph; Sure, Ulrich; Bertalanffy, Helmut

    2006-07-01

    The purpose of this article is to focus for the first time on the operative management of a direct vertebral artery (VA)-posterior inferior cerebellar artery (PICA) end-to-end anastomosis in a partially thrombosed giant VA-PICA-complex aneurysm and to underline its usefulness as an additional treatment option. The operative technique of a direct VA-PICA end-to-end anatomosis is described in detail. The VA was entering the large aneurysm sack. Distally, the PICA originated from the aneurysm sack-VA-complex. The donor and recipient vessel were cut close to the aneurysm. Whereas the VA was cut in a straight manner, the PICA was cut at an oblique 45-degree angle to enlarge the vascular end diameter. Vessel ends were flushed with heparinized saline and sutured. The thrombotic material inside the aneurysm sack was removed and the distal VA clipped, leaving the anterior spinal artery and brainstem perforators free. The patient regained consciousness without additional morbidity. Magnetic resonance imaging scans revealed a completely decompressed brainstem without infarction. The postoperative angiograms demonstrated a good filling of the anastomosed PICA. Despite the caliber mistmatch of these two vessels the direct VA-PICA end-to-end anastomosis provides an accurate alternative in addition to other anastomoses and bypass techniques, when donor and recipient vessels are suitable and medullary perforators do not have to be disrupted.

  1. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  2. Evaluation of different diameter arterial tubing and arterial cannulae in simulated neonatal/pediatric cardiopulmonary bypass circuits.

    Science.gov (United States)

    Wang, Shigang; Rosenthal, Tami; Kunselman, Allen R; Ündar, Akif

    2015-01-01

    The objective of this study is to evaluate three different diameters of arterial tubing and three diameters of arterial cannulae in terms of pressure drop, and hemodynamic energy delivery in simulated neonatal/pediatric cardiopulmonary bypass (CPB) circuits. The CPB circuit consisted of a Terumo Capiox Baby FX05 oxygenator (Terumo Corporation, Tokyo, Japan), arterial tubing (1/4 in, 3/16 in, or 1/8 in × 150 cm), and a Medtronic Bio-Medicus arterial cannula (8, 10, or 12 Fr; Medtronic, Inc., Minneapolis, MN, USA). The pseudo patient's pressure was maintained at 50 mm Hg. The circuit was primed using lactated Ringer's solution and heparinized packed human red blood cells (hematocrit 30%). Trials were conducted at different flow rates and temperatures (35 and 28°C). Flow and pressure data were collected using a custom-based data acquisition system. Using 8 Fr arterial cannula at 500 mL/min, small diameter arterial tubing generated higher circuit pressure (294.6 ± 0.1 mm Hg [1/8 in], 213.5 ± 0.5 mm Hg [3/16 in], 208.4 ± 0.4 mm Hg [1/4 in] at 35°C) and arterial line pressure drop (158.3 ± 0.1 mm Hg [1/8 in], 79.6 ± 0.1 mm Hg [3/16 in], 62.1 ± 0.1 mm Hg [1/4 in] at 35°C). Using 10 Fr arterial cannula at 1000 mL/min, pre-oxygenator pressures were 266.8 ± 0.2 mm Hg (3/16 in) and 248.0 ± 0.3 mm Hg (1/4 in); arterial line pressure drops were 111.6 ± 0.0 mm Hg (3/16 in) and 74.0 ± 0.1 mm Hg (1/4 in) at 35°C. When using 12 Fr arterial cannula at 1500 mL/min, preoxygenator pressures reached 324.4 ± 0.3 mm Hg (3/16 in) and 302.5 ± 0.4 mm Hg (1/4 in); arterial line pressure drops were 154.0 ± 0.1 mm Hg (3/16 in) and 92.0 ± 0.2 mm Hg (1/4 in) at 35°C. Pressure drops across arterial line tubing were main CPB circuit pressure drops. High flow rate, hypothermia, small diameter arterial tubing. and

  3. The alveolar to arterial oxygen partial pressure difference is associated with pulmonary diffusing capacity in heart failure patients.

    Science.gov (United States)

    Morosin, Marco; Vignati, Carlo; Novi, Angela; Salvioni, Elisabetta; Veglia, Fabrizio; Alimento, Marina; Merli, Guido; Sciomer, Susanna; Sinagra, Gianfranco; Agostoni, Piergiuseppe

    2016-11-01

    In chronic heart failure (HF), the alveolar-capillary membrane undergoes a remodeling process that negatively affects gas exchange. In case of alveolar-capillary gas diffusion impairment, arterial desaturation (SaO 2 ) is rarely observed in HF patients. At play are 3 factors: overall pulmonary diffusing capacity (assessed as lung diffusion for CO, DLCO), global O 2 consumption (VO 2 ) and alveolar (A) to arterial (a) pO 2 gradient (AaDO 2 ). In 100 consecutive stable HF patients, DLCO, resting respiratory gases and arterial blood gases were measured to determine VO 2, paO 2 , pAO 2 and AaDO 2 . DLCO was poorly but significantly related to AaDO 2 . The correlation improved after correcting AaDO 2 for VO 2 (p<0.001, r=0.49). Both VO 2 and AaDO 2 were independently associated with DLCO (p<0.001). Patients with reduced DLCO showed no differences as regards paO 2 and pAO 2 . AaDO 2 /VO 2 showed a higher gradient in patients with lower DLCO. AaDO 2 increase and VO 2 reduction allow preventing low SaO 2 in HF patients with reduced DLCO. Accordingly, we suggest considering AaDO 2 and VO 2 combined and reporting AaDO 2 /VO 2 . Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Effects of arm elevation on radial artery pressure: a new method to distinguish hypovolemic shock and septic shock from hypotension.

    Science.gov (United States)

    Xie, Zhiyi; Zhang, Zhenyu; Xu, Yuan; Zhou, Hua; Wu, Sheng; Wang, Zhong

    2018-06-01

    In this prospective observational study, we investigated the variability in radial artery invasive blood pressure associated with arm elevation in patients with different hemodynamic types. We carried out a prospective observational study using data from 73 general anesthesia hepatobiliary postoperative adult patients admitted to an ICU over a 1-year period. A standard procedure was used for the arm elevation test. The value of invasive radial arterial pressure was recorded at baseline, and 30 and 60 s after the arm had been raised from 0° to 90°. We compared the blood pressure before versus after arm elevation, and between hemodynamically stable, hypovolemic shock, and septic shock patient groups. In all 73 patients, systolic arterial pressure (SAP) decreased, diastolic arterial pressure (DAP) increased, and pulse pressure (PP) decreased at 30 and 60 s after arm elevation (Ppressure (MAP) was unchanged (P>0.05). On comparing 30 and 60 s, there was no significant difference in SAP, DAP, PP, or MAP (P>0.05). In 40 hemodynamically stable patients, SAP and PP decreased, and DAP and MAP increased significantly at 30 and 60 s after arm elevation compared with baseline (P0.05). In 17 patients with septic shock, SAP, PP, and MAP decreased significantly versus baseline at 30 and 60 s (P0.05). Comparison of the absolute value of pressure change of septic shock patients at 30 s after raising the arm showed that SAP, DAP, and MAP changes were significantly lower compared with those in hypovolemic shock and hemodynamically stable patients (Parm elevation of SAP. The best cut-off point for the SAP change value was -5 mmHg or less, with a sensitivity of 94.12%, a specificity of 80.36%, a positive likelihood ratio of 4.79 (95% CI: 2.8-8.2), and a negative likelihood ratio of 0.073 (95% CI: 0.01-0.5). Our study shows that hypovolemic shock and septic shock patients have significantly different radial artery invasive blood pressure changes in an arm elevation test

  5. Intracranial carotid anastomosis and partial aplasia of an internal carotid artery

    International Nuclear Information System (INIS)

    Huber, G.

    1980-01-01

    A rare arterial anastomosis between the right and left interal carotid arteries at the base at the skull, with aplasia of the cervical part of the left internal carotid artery is reported. The case is unusual because, in addition to the vascular anomaly of the carotid artery, there is an aneurysm of the anterior communicating artery and bilateral renal cysts. The condition is a complex malformation syndrome caused by defective regression of the third branchial artery. Because of the characteristic angiographic aspects such a case should be called transverse carotid anastomosis. (orig.)

  6. Intracranial carotid anastomosis and partial aplasia of an internal carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Huber, G.

    1980-12-01

    A rare arterial anastomosis between the right and left internal carotid arteries at the base at the skull, with aplasia of the cervical part of the left internal carotid artery is reported. The case is unusual because, in addition to the vascular anomaly of the carotid artery, there is an aneurysm of the anterior communicating artery and bilateral renal cysts. The condition is a complex malformation syndrome caused by defective regression of the third branchial artery. Because of the characteristic angiographic aspects such a case should be called transverse carotid anastomosis.

  7. Fluid responsiveness predicted by transcutaneous partial pressure of oxygen in patients with circulatory failure: a prospective study.

    Science.gov (United States)

    Xu, Jingyuan; Peng, Xiao; Pan, Chun; Cai, Shixia; Zhang, Xiwen; Xue, Ming; Yang, Yi; Qiu, Haibo

    2017-12-01

    Significant effort has been devoted to defining parameters for predicting fluid responsiveness. Our goal was to study the feasibility of predicting fluid responsiveness by transcutaneous partial pressure of oxygen (PtcO 2 ) in the critically ill patients. This was a single-center prospective study conducted in the intensive care unit of a tertiary care teaching hospital. Shock patients who presented with at least one clinical sign of inadequate tissue perfusion, defined as systolic blood pressure 40 mmHg in previously hypertensive patients or the need for vasopressive drugs; urine output 4 mmol/l, for less than 24 h in the absence of a contraindication for fluids were eligible to participate in the study. PtcO 2 was continuously recorded before and during a passive leg raising (PLR) test, and then before and after a 250 ml rapid saline infusion in 10 min. Fluid responsiveness is defined as a change in the stroke volume ≥10% after 250 ml of volume infusion. Thirty-four patients were included, and 14 responded to volume expansion. In the responders, the mean arterial pressure, central venous pressure, cardiac output, stroke volume and PtcO 2 increased significantly, while the heart rate decreased significantly by both PLR and volume expansion. Changes in the stroke volume induced either by PLR or volume expansion were significantly greater in responders than in non-responders. The correlation between the changes in PtcO 2 and stroke volume induced by volume expansion was significant. Volume expansion induced an increase in the PtcO 2 of 14% and PLR induced an increase in PtcO 2 of 13% predicted fluid responsiveness. This study suggested the changes in PtcO 2 induced by volume expansion and a PLR test predicted fluid responsiveness in critically ill patients. Trial registration NCT02083757.

  8. Passive heat therapy improves endothelial function, arterial stiffness and blood pressure in sedentary humans.

    Science.gov (United States)

    Brunt, Vienna E; Howard, Matthew J; Francisco, Michael A; Ely, Brett R; Minson, Christopher T

    2016-09-15

    A recent 30 year prospective study showed that lifelong sauna use reduces cardiovascular-related and all-cause mortality; however, the specific cardiovascular adaptations that cause this chronic protection are currently unknown. We investigated the effects of 8 weeks of repeated hot water immersion ('heat therapy') on various biomarkers of cardiovascular health in young, sedentary humans. We showed that, relative to a sham group which participated in thermoneutral water immersion, heat therapy increased flow-mediated dilatation, reduced arterial stiffness, reduced mean arterial and diastolic blood pressure, and reduced carotid intima media thickness, with changes all on par or greater than what is typically observed in sedentary subjects with exercise training. Our results show for the first time that heat therapy has widespread and robust effects on vascular function, and as such, could be a viable treatment option for improving cardiovascular health in a variety of patient populations, particularly those with limited exercise tolerance and/or capabilities. The majority of cardiovascular diseases are characterized by disorders of the arteries, predominantly caused by endothelial dysfunction and arterial stiffening. Intermittent hot water immersion ('heat therapy') results in elevations in core temperature and changes in cardiovascular haemodynamics, such as cardiac output and vascular shear stress, that are similar to exercise, and thus may provide an alternative means of improving health which could be utilized by patients with low exercise tolerance and/or capabilities. We sought to comprehensively assess the effects of 8 weeks of heat therapy on biomarkers of vascular function in young, sedentary subjects. Twenty young, sedentary subjects were assigned to participate in 8 weeks (4-5 times per week) of heat therapy (n = 10; immersion in a 40.5°C bath sufficient to maintain rectal temperature ≥ 38.5°C for 60 min per session) or thermoneutral water

  9. Increased pulmonary artery pressures during exercise are related to persistent tricuspid regurgitation after atrial septal defect closure.

    Science.gov (United States)

    De Meester, Pieter; Van De Bruaene, Alexander; Herijgers, Paul; Voigt, Jens-Uwe; Vanhees, Luc; Budts, Werner

    2013-08-01

    Although closure of an atrial septal defect type secundum often normalizes right heart dimensions and pressures, mild tricuspid insufficiency might persist. This study aimed at (1) identification of determinants explaining the persistence of tricuspid insufficiency after atrial septal defect closure, and (2) evaluation of functional capacity of patients with persistent mild tricuspid insufficiency. Twenty-five consecutive patients (age 42+17 y) were included from the outpatient clinic of congenital heart disease at the University Hospitals of Leuven. All underwent transthoracic echocardiography, semi-supine bicycle stress echocardiography and cardio-pulmonary exercise testing. Six patients (24%) had mild tricuspid insufficiency (2/4) compared to 19 patients (76%) with no or minimal tricuspid insufficiency ( 1/4) as assessed by semi-quantitative colour Doppler echocardiography. Mann-Whitney U and Fisher's exact tests were performed where applicable. Patients with persistent mild tricuspid insufficiency were significantly older than those with no or minimal tricuspid insufficiency (P = 0.042). At rest, no differences in right heart configuration, mean pulmonary artery pressure or right ventricular function were found. At peak exercise, mean pulmonary artery pressure was significantly higher in patients with mild persistent tricuspid insufficiency (P = 0.026). Peak oxygen uptake was significantly lower in patients with mild persistent tricuspid insufficiency (P = 0.019). Mild tricuspid insufficiency after atrial septal defect repair occurs more frequently in older patients and in patients with higher mean pulmonary artery pressure at peak exercise. In patients with mild tricuspid insufficiency, functional capacity was more reduced. Mild tricuspid insufficiency could be a marker of subclinical persistent pressure load on the right ventricle.

  10. Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

    Science.gov (United States)

    Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

  11. Evaluation of an isotope washout technique to measure skin vascular resistance and skin perfusion pressure: influence of age, site and arterial surgery

    International Nuclear Information System (INIS)

    Duncan, H.J.; Faris, I.B.

    1986-01-01

    1. A simplified isotope (sup(99m)Tc) washout technique has been devised to calculate the skin perfusion pressure (SPP) and skin vascular resistance (SVR). This test is simple, requires inexpensive equipment and is well tolerated by patients. 2. SPP and SVR were calculated in 20 patients 30 years of age and in 15 patients with peripheral vascular disease (PVD). With increasing age the SPP and SVP were increased. The SPP was similar to the mean arterial pressure in normal individuals but was decreased in patients with PVD. The SPP is a useful indicator of the severity of the PVD. 3. The SPP and SVR were higher in the calf than in the foot. This is probably related to the decrease in pressure in the distal arterial tree. 4. SPP was increased by 110% and skin blood flow by 190% by arterial reconstructive surgery. This test may be of use in assessing the effectiveness of arterial surgery. (author)

  12. Mean pressure of pulmonary arteries in non-callous silicosis at states 1 to 2 as determined by radiology in comparison to parameters of pulmonary function

    Energy Technology Data Exchange (ETDEWEB)

    Jakob, M; Konrad, A; Adam, P; Scharf, R

    1984-11-19

    Fifty coal miners suffering from reticulonodular silicosis underwent catheterization of the right heart and showed latent or manifest pulmonary hypertension. It has been found that the statistical relationship between pulmonary arterial pressure and pulmonary function was only a loose one. Thirty percent of the studied subjects presented no alterations of the lung function but an increased pulmonary artery mean pressure at rest and under exercise, indicating that the Euler-Liljestrand-mechanism could hardly be responsible for these pressure changes. Subjects with silicosis who presented impaired lung function showed statistically significant higher pulmonary artery pressures than those without alteration of the lung function. It is likely that an additional pressure increase occurs secondary to Euler-Liljestrand-mechanism, when restrictive or obstructive impairments of ventilation emerge from the pneumoconiosis.

  13. Increased augmentation index and central systolic arterial pressure are associated with lower school and motor performance in young adolescents.

    Science.gov (United States)

    Vogrin, Bernarda; Slak Rupnik, Marjan; Mičetić-Turk, Dušanka

    2017-12-01

    Objective In adults, improper arterial function has been linked to cognitive impairment. The pulse wave velocity (PWV), augmentation index (AIx) and other vascular parameters are useful indicators of arterial health. In our study, we monitored arterial properties, body constitution, school success, and motor skills in young adolescents. We hypothesize that reduced cognitive and motor abilities have a vascular origin in children. Methods We analysed 81 healthy school children aged 11-16 years. Anthropometry central systolic arterial pressure, body mass index (BMI), standard deviation scores (SDS) BMI, general school performance grade, and eight motor tests were assessed. PWV, AIx, and central systolic arterial pressure (SBPao) were measured. Results AIx and SBPao correlated negatively with school performance grades. Extremely high AIx, PWV and SBPao values were observed in 5% of children and these children had average to low school performance. PWV correlated significantly with weight, height, and waist and hip circumference. AIx, PWV, school success, and BMI correlated strongly with certain motor functions. Conclusions Increased AIx and SBPao are associated with lower school and motor performance in children. PWV is influenced by the body's constitution.

  14. Effect of Oxygen Partial Pressure on the Electrical and Optical Properties of DC Magnetron Sputtered Amorphous TiO2 Films

    OpenAIRE

    Chandra Sekhar, M.; Kondaiah, P.; Radha Krishna, B.; Uthanna, S.

    2013-01-01

    Titanium dioxide (TiO2) thin films were deposited on p-Si (100) and Corning glass substrates held at room temperature by DC magnetron sputtering at different oxygen partial pressures in the range 9 × 10−3–9 × 10−2 Pa. The influence of oxygen partial pressure on the structural, electrical, and optical properties of the deposited films was systematically studied. XPS studies confirmed that the film formed at an oxygen partial pressure of 6×10−2 Pa was nearly stoichiometric. TiO2 films formed at...

  15. The effect of pressure-controlled inverse ratio ventilation on lung protection in obese patients undergoing gynecological laparoscopic surgery.

    Science.gov (United States)

    Xu, Lili; Shen, Jianjun; Yan, Min

    2017-10-01

    To examine the effects of pressure-controlled inverse ratio ventilation (PCIRV) and volume-control ventilation (VCV) on arterial oxygenation, pulmonary function, hemodynamics, levels of surfactant protein A (SP-A), and tumor necrosis factor-α (TNF-α) in obese patients undergoing gynecological laparoscopic surgery. Sixty patients, body mass index (BMI) ≥30 kg/m 2 , scheduled for elective gynecological laparoscopic surgery were enrolled in the study. Patients were randomly allocated to receive either PCIRV with an inspiratory-expiratory (I:E) ratio of 1.5:1 (PCIRV group n = 30) or VCV with an I:E ratio of 1:2 (VCV group n = 30). Ventilation variables, viz. tidal volume (V T ), dynamic respiratory-system compliance (C RS ), driving pressure (ΔP = V T /C RS ), arterial blood oxygen partial pressure/fraction of inspiration oxygen (PaO 2 /FiO 2 ) and arterial blood carbon dioxide partial pressure (PaCO 2 ), were measured. Hemodynamic variables, viz. mean arterial pressure (MAP), heart rate (HR), and serum levels of SP-A and TNF-α, were also measured. When compared to patients in the VCV group, patients in the PCIRV group had higher V T , dynamic C RS , and PaO 2 /FiO 2 , and lower ΔP and PaCO 2 at 20 and 60 min after the start of pneumoperitoneum (p ventilation, promote gas exchange and oxygenation, and is associated with decreased levels of SP-A and TNF-α. These effects demonstrate improved lung protection provided by PCIRV in this patient population.

  16. Measuring systolic arterial blood pressure. Possible errors from extension tubes or disposable transducer domes.

    Science.gov (United States)

    Rothe, C F; Kim, K C

    1980-11-01

    The purpose of this study was to evaluate the magnitude of possible error in the measurement of systolic blood pressure if disposable, built-in diaphragm, transducer domes or long extension tubes between the patient and pressure transducer are used. Sinusoidal or arterial pressure patterns were generated with specially designed equipment. With a long extension tube or trapped air bubbles, the resonant frequency of the catheter system was reduced so that the arterial pulse was amplified as it acted on the transducer and, thus, gave an erroneously high systolic pressure measurement. The authors found this error to be as much as 20 mm Hg. Trapped air bubbles, not stopcocks or connections, per se, lead to poor fidelity. The utility of a continuous catheter flush system (Sorenson, Intraflow) to estimate the resonant frequency and degree of damping of a catheter-transducer system is described, as are possibly erroneous conclusions. Given a rough estimate of the resonant frequency of a catheter-transducer system and the magnitude of overshoot in response to a pulse, the authors present a table to predict the magnitude of probable error. These studies confirm the variability and unreliability of static calibration that may occur using some safety diaphragm domes and show that the system frequency response is decreased if air bubbles are trapped between the diaphragms. The authors conclude that regular procedures should be established to evaluate the accuracy of the pressure measuring systems in use, the transducer should be placed as close to the patient as possible, the air bubbles should be assiduously eliminated from the system.

  17. Cerebral blood flow response to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Kern, F.H.; Ungerleider, R.M.; Quill, T.J.; Baldwin, B.; White, W.D.; Reves, J.G.; Greeley, W.J.

    1991-01-01

    We examined the relationship of changes in partial pressure of carbon dioxide on cerebral blood flow responsiveness in 20 pediatric patients undergoing hypothermic cardiopulmonary bypass. Cerebral blood flow was measured during steady-state hypothermic cardiopulmonary bypass with the use of xenon 133 clearance methodology at two different arterial carbon dioxide tensions. During these measurements there was no significant change in mean arterial pressure, nasopharyngeal temperature, pump flow rate, or hematocrit value. Cerebral blood flow was found to be significantly greater at higher arterial carbon dioxide tensions (p less than 0.01), so that for every millimeter of mercury rise in arterial carbon dioxide tension there was a 1.2 ml.100 gm-1.min-1 increase in cerebral blood flow. Two factors, deep hypothermia (18 degrees to 22 degrees C) and reduced age (less than 1 year), diminished the effect carbon dioxide had on cerebral blood flow responsiveness but did not eliminate it. We conclude that cerebral blood flow remains responsive to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in infants and children; that is, increasing arterial carbon dioxide tension will independently increase cerebral blood flow

  18. Comparison of two methods of dental prophylaxis: evaluation of arterial pressure and patient comfort in a clinical randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Camila Lopes FERREIRA

    Full Text Available Abstract Introduction The number of hypertensive patients is increasing and prophylaxis with bicarbonate jet are widely performed in clinical practice using large amounts of this substance in a short period of time, which may lead to increased arterial pressure. In the literature there are several studies that analyze the effect of sodium bicarbonate jet on the biofilm and dental structures, but not report the effect on arterial pressure. Aim Evaluated the change in arterial pressure before and after two procedures of dental prophylaxis, jet baking soda application and conventional prophylaxis, and patient opinion of the comfort of each system was obtained. Material and method We selected 20 patients aged 18 to 30 in need of prophylaxis to remove biofilm. The patients were placed into three different treatment groups: sodium bicarbonate jet (G1, conventional prophylaxis (G2 and control (G3, with a one month interval between treatments. Patients were divided into groups randomly. Measurements were performed immediately before and after the procedure, 15 and 30 minutes after the end of treatment. Patient comfort was measured using a Visual Analog Scale (VAS at the end of each treatment. Data were analyzed by analysis of variance. Result There was a statistically significant difference in the comfort of the procedures, with G2 and G3 being better than G1. Additionally, an increase in the diastolic blood pressure was observed in sodium bicarbonate jet group evaluated just after the procedure. Conclusion The conventional prophylaxis is more comfortable from the patient stand point and does not alter arterial pressure.

  19. Hemodialysis catheter insertion: is increased PO2 a sign of arterial cannulation? A case report.

    Science.gov (United States)

    Chirinos, Julio C; Neyra, Javier A; Patel, Jiten; Rodan, Aylin R

    2014-07-29

    Ultrasound-guided Central Venous Catheterization (CVC) for temporary vascular access, preferably using the right internal jugular vein, is widely accepted by nephrologists. However CVC is associated with numerous potential complications, including death. We describe the finding of a rare left-sided partial anomalous pulmonary vein connection during central venous catheterization for continuous renal replacement therapy (CRRT). Ultrasound-guided cannulation of a large bore temporary dual-lumen Quinton-Mahurkar catheter into the left internal jugular vein was performed for CRRT initiation in a 66 year old African-American with sepsis-related oliguric acute kidney injury. The post-procedure chest X-ray suggested inadvertent left carotid artery cannulation. Blood gases obtained from the catheter showed high partial pressure of oxygen (PO2) of 140 mmHg and low partial pressure of carbon dioxide (PCO2) of 22 mmHg, suggestive of arterial cannulation. However, the pressure-transduced wave forms appeared venous and Computed Tomography Angiography located the catheter in the left internal jugular vein, but demonstrated that the tip of the catheter was lying over a left pulmonary vein which was abnormally draining into the left brachiocephalic (innominate) vein rather than into the left atrium. Although several mechanical complications of dialysis catheters have been described, ours is one of the few cases of malposition into an anomalous pulmonary vein, and highlights a sequential approach to properly identify the catheter location in this uncommon clinical scenario.

  20. The acute effects of lower limb intermittent negative pressure on foot macro- and microcirculation in patients with peripheral arterial disease.

    Directory of Open Access Journals (Sweden)

    Øyvind Heiberg Sundby

    Full Text Available Intermittent negative pressure (INP applied to the lower leg and foot increases foot perfusion in healthy volunteers. The aim of the present study was to describe the effects of INP to the lower leg and foot on foot macro- and microcirculation in patients with lower extremity peripheral arterial disease (PAD.In this experimental study, we analyzed foot circulation during INP in 20 patients [median (range: 75 (63-84yrs] with PAD. One leg was placed inside an air-tight vacuum chamber connected to an INP-generator. During application of INP (alternating 10s of -40mmHg/7s of atmospheric pressure, we continuously recorded blood flow velocity in a distal foot artery (ultrasound Doppler, skin blood flow on the pulp of the first toes (laser Doppler, heart rate (ECG, and systemic blood pressure (Finometer. After a 5-min baseline sequence (no pressure, a 10-min INP sequence was applied, followed by 5-min post-INP (no pressure. To compare and quantify blood flow fluctuations between sequences, we calculated cumulative up-and-down fluctuations in arterial blood flow velocity per minute.Onset of INP induced an increase in arterial flow velocity and skin blood flow. Peak blood flow velocity was reached 3s after the onset of negative pressure, and increased 46% [(95% CI 36-57, P<0.001] above baseline. Peak skin blood flow was reached 2s after the onset of negative pressure, and increased 89% (95% CI 48-130, P<0.001 above baseline. Cumulative fluctuations per minute were significantly higher during INP-sequences compared to baseline [21 (95% CI 12-30cm/s/min to 41 (95% CI 32-51cm/s/min, P<0.001]. Mean INP blood flow velocity increased significantly ~12% above mean baseline blood flow velocity [(6.7 (95% CI 5.2-8.3cm/s to 7.5 (95% CI 5.9-9.1cm/s, P = 0.03].INP increases foot macro- and microcirculatory flow pulsatility in patients with PAD. Additionally, application of INP resulted in increased mean arterial blood flow velocity.

  1. Increasing arterial blood pressure with norepinephrine does not improve microcirculatory blood flow: a prospective study

    NARCIS (Netherlands)

    Dubin, Arnaldo; Pozo, Mario O.; Casabella, Christian A.; Palizas, Fernando; Murias, Gaston; Moseinco, Miriam C.; Kanoore Edul, Vanina S.; Estenssoro, Elisa; Ince, Can

    2009-01-01

    Introduction Our goal was to assess the effects of titration of a norepinephrine infusion to increasing levels of mean arterial pressure (MAP) on sublingual microcirculation. Methods Twenty septic shock patients were prospectively studied in two teaching intensive care units. The patients were

  2. Effect of partial sports massage on blood pressure and heart rate

    Directory of Open Access Journals (Sweden)

    T.D. Pystupa

    2013-12-01

    Full Text Available With the growing popularity and demand for different types of massages (including sports is a growing need for research on specific forms. There is also a need to study the advantages and effects on various body functions. The objective was to study the effect of partial sports massage on blood pressure and heart rate in both men and women. Material and methods. Research has been extended 80 healthy men and women are physically active (age 20-25 years. Blood pressure and heart rate were made on the left arm automatic digital device (model HEM - 907. The device is intended to measure blood pressure. It is established that it is possible to verify the existing beliefs. This promotes more efficient use of massage therapy. Conclusions . Sports massage has an effect on hemodynamic changes, the increase (decrease in blood pressure acceleration (deceleration of the heart rate. It depends on what part of the body exposed to the massage procedure.

  3. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Directory of Open Access Journals (Sweden)

    Amann Matthias

    2007-11-01

    Full Text Available Abstract Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC measurement by the pulmonary artery catheter (PAC. However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years, who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min. The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC and percentage changes in COAP (ΔCOAP for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p PAC and ΔCOAP was 0.46 (p Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03 failed to

  4. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Science.gov (United States)

    Prasser, Christopher; Bele, Sylvia; Keyl, Cornelius; Schweiger, Stefan; Trabold, Benedikt; Amann, Matthias; Welnhofer, Julia; Wiesenack, Christoph

    2007-01-01

    Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC) and percentage changes in COAP (ΔCOAP) for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p < 0.01), while the correlation coefficient between ΔCOPAC and ΔCOAP was 0.46 (p < 0.01). Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore

  5. Association of thyroid function with arterial pressure in normotensive and hypertensive euthyroid individuals: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Saltiki Katerina

    2008-09-01

    Full Text Available Abstract Background Overt hypothyroidism has been associated with arterial hypertension and increased arterial stiffness. Results in euthyroid individuals have been conflicting. We investigated associations of thyroid function with systolic (SAP and diastolic (DAP arterial pressure in euthyroid subjects. Methods 311 euthyroid individuals (185 women, mean age 43.9 ± 9 without a history of diabetes attending a preventive medicine program were examined. Subjects receiving thyroxine (10.6% were excluded; 19.3% had hypertension, 43% had a family history for hypertension. TSH, fT4, thyroid autoantibodies, insulin, glucose were measured. The "fT4.TSH product", which has been suggested as a T4 resistance-index, was calculated. Results TSH range was 0.1–8, median 1.4 mU/L, fT4 range was 11.5–25.2 pmol/L, median 17.4. TSH and the "fT4.TSH product" were positively associated with DAP (p 2 mU/L (35.3% vs 21.3%, p = 0.045. Conclusion In euthyroid individuals the association of thyroid function with diastolic arterial pressure remains significant even when a stricter "normal range" for TSH levels is considered. The "freeT4.TSH" product appears to be an even stronger predictor of DAP, independently of HOMA insulin resistance index and obesity.

  6. Effects of mercury on the arterial blood pressure of anesthetized rats

    Directory of Open Access Journals (Sweden)

    Rossoni L.V.

    1999-01-01

    Full Text Available The available data suggests that hypotension caused by Hg2+ administration may be produced by a reduction of cardiac contractility or by cholinergic mechanisms. The hemodynamic effects of an intravenous injection of HgCl2 (5 mg/kg were studied in anesthetized rats (N = 12 by monitoring left and right ventricular (LV and RV systolic and diastolic pressures for 120 min. After HgCl2 administration the LV systolic pressure decreased only after 40 min (99 ± 3.3 to 85 ± 8.8 mmHg at 80 min. However, RV systolic pressure increased, initially slowly but faster after 30 min (25 ± 1.8 to 42 ± 1.6 mmHg at 80 min. Both right and left diastolic pressures increased after HgCl2 treatment, suggesting the development of diastolic ventricular dysfunction. Since HgCl2 could be increasing pulmonary vascular resistance, isolated lungs (N = 10 were perfused for 80 min with Krebs solution (continuous flow of 10 ml/min containing or not 5 µM HgCl2. A continuous increase in pulmonary vascular resistance was observed, suggesting the direct effect of Hg2+ on the pulmonary vessels (12 ± 0.4 to 29 ± 3.2 mmHg at 30 min. To examine the interactions of Hg2+ and changes in cholinergic activity we analyzed the effects of acetylcholine (Ach on mean arterial blood pressure (ABP in anesthetized rats (N = 9 before and after Hg2+ treatment (5 mg/kg. Using the same amount and route used to study the hemodynamic effects we also examined the effects of Hg2+ administration on heart and plasma cholinesterase activity (N = 10. The in vivo hypotensive response to Ach (0.035 to 10.5 µg was reduced after Hg2+ treatment. Cholinesterase activity (µM h-1 mg protein-1 increased in heart and plasma (32 and 65%, respectively after Hg2+ treatment. In conclusion, the reduction in ABP produced by Hg2+ is not dependent on a putative increase in cholinergic activity. HgCl2 mainly affects cardiac function. The increased pulmonary vascular resistance and cardiac failure due to diastolic

  7. Peripheral and central arterial pressure and its relationship to vascular target organ damage in carotid artery, retina and arterial stiffness. Development and validation of a tool. The Vaso risk study

    Directory of Open Access Journals (Sweden)

    Patino-Alonso Maria C

    2011-04-01

    Full Text Available Abstract Background Ambulatory blood pressure monitoring (ABPM shows a better correlation to target organ damage and cardiovascular morbidity-mortality than office blood pressure. A loss of arterial elasticity and an increase in carotid artery intima-media thickness (IMT has been associated with increased cardiovascular morbidity-mortality. Tools have been developed that allow estimation of the retinal arteriovenous index but not all studies coincide and there are contradictory results in relation to the evolution of the arteriosclerotic lesions and the caliber of the retinal vessels. The purpose of this study is to analyze the relationship between peripheral and central arterial pressure (clinic and ambulatory and vascular structure and function as evaluated by the carotid artery intima-media thickness, retina arteriovenous index, pulse wave velocity (PWV and ankle-brachial index in patients with and without type 2 diabetes. In turn, software is developed and validated for measuring retinal vessel thickness and automatically estimating the arteriovenous index. Methods/Design A cross-sectional study involving a control group will be made, with a posterior 4-year follow-up period in primary care. The study patients will be type 2 diabetics, with a control group of non-diabetic individuals. Consecutive sampling will be used to include 300 patients between 34-75 years of age and no previous cardiovascular disease, one-half being assigned to each group. Main measurements: age, gender, height, weight and abdominal circumference. Lipids, creatinine, microalbuminuria, blood glucose, HbA1c, blood insulin, high sensitivity C-reactive protein and endothelial dysfunction markers. Clinic and ambulatory blood pressure monitoring. Carotid ultrasound to evaluate IMT, and retinography to evaluate the arteriovenous index. ECG to assess left ventricle hypertrophy, ankle-brachial index, and pulse wave analysis (PWA and pulse wave velocity (PWV with the Sphigmocor

  8. Constriction of collateral arteries induced by "head-up tilt" in patients with occlusive arterial disease of the legs

    DEFF Research Database (Denmark)

    Agerskov, K; Henriksen, O; Tønnesen, K H

    1981-01-01

    The effect of head-up tilt on leg blood flow and segmental arterial blood pressures was studied in 21 patients with occlusion or severe stenosis of the common or superficial femoral artery. Arterial pressure was measured directly in the brachial artery, common femoral artery and popliteal artery....... Relative change in blood flow in the leg during tilt was estimated by changes in arterio-venous oxygen differences and by the indicator dilution technique in nine patients. Head-up tilt caused a decrease in leg blood flow of 36% corresponding to an increase in total vascular resistance of 57%. Tilt did...... not change the pressure gradient from femoral to popliteal artery in the patients with occlusion of the superficial femoral artery, indicating that the flow resistance offered by the collateral arteries had increased. In a bilateral sympathectomised patient the increase in collateral resistance was almost...

  9. Determining carotid artery pressure from scaled diameter waveforms: comparison and validation of calibration techniques in 2026 subjects

    International Nuclear Information System (INIS)

    Vermeersch, S J; Verdonck, P R; Segers, P; Rietzschel, E R; De Buyzere, M L; Gillebert, T C; De Bacquer, D; De Backer, G; Van Bortel, L M

    2008-01-01

    Calibrated diameter distension waveforms could provide an alternative for local arterial pressure assessment more widely applicable than applanation tonometry. We compared linearly and exponentially calibrated carotid diameter waveforms to tonometry readings. Local carotid pressures measured by tonometry and diameter waveforms measured by ultrasound were obtained in 2026 subjects participating in the Asklepios study protocol. Diameter waveforms were calibrated using a linear and an exponential calibration scheme and compared to measured tonometry waveforms by examining the mean root-mean-squared error (RMSE), carotid systolic blood pressure (SBP car ) and augmentation index (AIx) of calibrated and measured pressures. Mean RMSE was 5.2(3.3) mmHg (mean(stdev)) for linear and 4.6(3.6) mmHg for exponential calibration. Linear calibration yielded an underestimation of SBP car by 6.4(4.1) mmHg which was strongly correlated to values of brachial pulse pressure (PP bra ) (R = 0.4, P car by 1.9(3.9) mmHg, independent of PP bra . AIx was overestimated by linear calibration by 1.9(10.1)%, the difference significantly increasing with increasing AIx (R = 0.25, P < 0.001) and by exponential calibration by 5.4(10.6)%, independently of the value of AIx. Properly calibrated diameter waveforms offer a viable alternative for local pressure estimation at the carotid artery. Compared to linear calibration, exponential calibration significantly improves the pressure estimation

  10. Pressão arterial entre trabalhadores de curtume Blood pressure among tannery workers

    Directory of Open Access Journals (Sweden)

    Ricardo Cordeiro

    1998-10-01

    Full Text Available INTRODUÇÃO: O grupo das doenças cardiovasculares tem sido apontado como a principal causa de óbito no Brasil desde os anos 70, sendo a hipertensão arterial sistêmica (HAS o fator de risco mais importante para esse grupo. Entre os trabalhadores observa-se correlação negativa entre o status ocupacional e a pressão arterial. Tais fatos ressaltam a importância do conhecimento da distribuição da pressão arterial sistêmica entre os distintos grupos profissionais. Assim, foi realizado estudo para descrever o status pressórico de uma população homogênea e estável de trabalhadores do setor secundário da economia, pouco especializados e que ganham baixos salários, estabelecendo a prevalência da HAS nesse grupo específico, relacionando-a com algumas covariáveis biológicas e socioeconômicas, e comparando-a com a prevalência de HAS em outros grupos profissionais no Brasil. MÉTODO: Foram estudados 73 trabalhadores regularmente empregados em julho de 1993 em um curtume situado no Município de Botucatu, cidade de médio porte da região Centro-Oeste do Estado de São Paulo, os quais foram submetidos a exame antropométrico, aferição de pressão arterial, anamnese e exame clínico. Os resultados foram comparados com os obtidos em estudos semelhantes, controlando-se o confundimento da idade por intermédio de diferentes técnicas. RESULTADOS: A prevalência bruta da HAS encontrada foi de 56,1%, sendo 15,8% a prevalência de hipertensão sistólica isolada. Ambas se associaram ao etilismo e ao tabagismo na população estudada. DISCUSSÃO: A prevalência da hipertensão foi consideravelmente alta e significativamente maior do que a encontrada em outros grupos de trabalhadores estudados no Brasil. Tal achado ressalta a necessidade da continuidade da investigação, objetivando o isolamento dos fatores implicados na elevação pressórica do grupo estudado.INTRODUCTION: Cardiovascular diseases have been shown to be the leading cause of

  11. Relationship between pulmonary artery volumes at computed tomography and pulmonary artery pressures in patients with- and without pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Froelich, Jens J. [Department of Radiology, Philipps-University Hospital, Baldingerstrasse, 35043 Marburg (Germany)], E-mail: jens.froelich@klinikum-hef.de; Koenig, Helmut [Department of Radiology, Philipps-University Hospital, Baldingerstrasse, 35043 Marburg (Germany)], E-mail: helmut.koenig@siemens.com; Knaak, Lennard [Department of Medicine, Philipps-University Hospital, Baldingerstrasse, 35043 Marburg (Germany)], E-mail: froehlic@staff.uni-marburg.de; Krass, Stefan [MeVis Research, Universitaetsallee 29, 28359 Bremen (Germany)], E-mail: krass@mevis.de; Klose, Klaus J. [Department of Radiology, Philipps-University Hospital, Baldingerstrasse, 35043 Marburg (Germany)], E-mail: klose@med.uni-marburg.de

    2008-09-15

    Objectives: This study was designed to determine the relationship between pulmonary artery (PA) volumes at computed tomography (CT) and PA pressures at right-sided heart catheterization in patients with and without pulmonary hypertension (PAH) to develop a noninvasive CT method of PA pressure quantification. Materials and methods: Sixteen patients with chronic sleep apnea syndrome underwent contrast enhanced helical CT (slice thickness 3 mm; pitch 2; increment 2 mm) at inspiration. Eight patients had PAH while cardiopulmonary disease has been excluded in eight other patients. Vascular volumes were determined using a 3D technique (threshold seeded vascular tracing algorithm; thresholds -600 H [lower] and 3000 H [upper]). Right-sided heart catheterization measurements were available for linear regression analysis of PA volumes and pressures. Results: Correlation between PA pressures and volumes (normalized for BMI), was high in both groups (without PAH: r = .85; with PAH .90, Pearson). Compared to elevated PA pressures in patients with pulmonary hypertension (p < .005), PA volumes also were significantly increased (p < .05) among the groups. Conclusions: High correlation was found between PA volumes and mean PA pressures in patients with- and without PAH. Significant differences in PA volumes at CT-volumetry may admit non-invasive determination of pulmonary hypertension.

  12. Relationship between pulmonary artery volumes at computed tomography and pulmonary artery pressures in patients with- and without pulmonary hypertension

    International Nuclear Information System (INIS)

    Froelich, Jens J.; Koenig, Helmut; Knaak, Lennard; Krass, Stefan; Klose, Klaus J.

    2008-01-01

    Objectives: This study was designed to determine the relationship between pulmonary artery (PA) volumes at computed tomography (CT) and PA pressures at right-sided heart catheterization in patients with and without pulmonary hypertension (PAH) to develop a noninvasive CT method of PA pressure quantification. Materials and methods: Sixteen patients with chronic sleep apnea syndrome underwent contrast enhanced helical CT (slice thickness 3 mm; pitch 2; increment 2 mm) at inspiration. Eight patients had PAH while cardiopulmonary disease has been excluded in eight other patients. Vascular volumes were determined using a 3D technique (threshold seeded vascular tracing algorithm; thresholds -600 H [lower] and 3000 H [upper]). Right-sided heart catheterization measurements were available for linear regression analysis of PA volumes and pressures. Results: Correlation between PA pressures and volumes (normalized for BMI), was high in both groups (without PAH: r = .85; with PAH .90, Pearson). Compared to elevated PA pressures in patients with pulmonary hypertension (p < .005), PA volumes also were significantly increased (p < .05) among the groups. Conclusions: High correlation was found between PA volumes and mean PA pressures in patients with- and without PAH. Significant differences in PA volumes at CT-volumetry may admit non-invasive determination of pulmonary hypertension

  13. Dorsalis pedis arterial pressure is lower than noninvasive arm blood pressure in normotensive patients under sevoflurane anesthesia.

    Science.gov (United States)

    Chen, Yan; Wang, Enqin; Zhu, Yuan; Li, Yongshuai; Lu, Kaizhi

    2016-02-01

    It is widely known that blood pressure (BP) in the lower extremity is higher than in the upper extremity. However, whether this phenomenon remains the same during general anesthesia is still unclear. This study aims to investigate the difference between invasive dorsalis pedis artery (DPA) pressure and the most commonly used noninvasive arm pressure during sevoflurane anesthesia. A total of 50 normotensive Chinese patients were enrolled in this observational study. Invasive DPA pressure, noninvasive arm pressure, and systemic vascular resistance index were assessed simultaneously. BP data during the entire surgery were analyzed through a Bland-Altman plot for repeated measures. The concordance of BP variation in the DPA and the arm was analyzed using four-quadrant plots and linear regression. The time-dependent changes in BP and the systemic vascular resistance index were also evaluated. Data from 46 effective cases were analyzed. Bias (95% limits of agreement) was -7.40 mmHg (-20.36 to +5.57 mmHg) for mean blood pressure, +3.54 mmHg (-20.32 to +27.41 mmHg) for systolic blood pressure, and -10.20 mmHg (-23.66 to +3.26 mmHg) for diastolic blood pressure, respectively. The concordance of BP variation at the two measurement sites was clinically acceptable. DPA pressure and vascular resistance in the lower limb decreased gradually during surgery. DPA pressure tends to be lower than arm pressure under sevoflurane anesthesia, especially the mean blood pressure and the diastolic blood pressure. Hence, noninvasive arm BP monitoring is recommend to be retained when invasive BP is measured at the DPA, so as to allow clinicians to comprehensively evaluate the BP condition of the patients and make appropriate therapeutic decisions.

  14. Reduction of Blood Pressure Following After Renal Artery Adventitia Stripping During Total Nephroureterectomy: Potential Effect of Renal Sympathetic Denervation.

    Science.gov (United States)

    Okamura, Keisuke; Satou, Shunsuke; Setojima, Keita; Shono, Shinjiro; Miyajima, Shigero; Ishii, Tatsu; Shirai, Kazuyuki; Urata, Hidenori

    2018-05-16

    BACKGROUND Catheter-based renal sympathetic denervation has been reported to be effective for treatment resistance hypertension in Australia and Europe. However, in the blinded SYMPLICITY HTN-3 trial, renal denervation did not achieve a significant decrease in blood pressure (BP) in comparison to sham controls. There have been various discussions on the factors that influenced this result. CASE REPORT Two men on antihypertensive therapy underwent unilateral radical nephroureterectomy for cancer of the renal pelvis. When the renal artery adventitia was stripped and cauterized just before renal artery ligation, the measured BP of the 2 men increased after stripping adventitia and decreased gradually after cauterization of the renal artery. This was presumably due to removal of renal artery sympathetic nerves, similar to the mechanism of catheter-based renal sympathetic denervation, although anesthesia, fluid infusion, and/or mesenteric traction may have had an influence. CONCLUSIONS A similar strategy involving thoracolumbar sympathectomy was reported about 50 years ago. The clinically significant blood pressure reduction in these patients suggests renal denervation is effective.

  15. Renal artery anatomy affects the blood pressure response to renal denervation in patients with resistant hypertension.

    Science.gov (United States)

    Hering, Dagmara; Marusic, Petra; Walton, Antony S; Duval, Jacqueline; Lee, Rebecca; Sata, Yusuke; Krum, Henry; Lambert, Elisabeth; Peter, Karlheinz; Head, Geoff; Lambert, Gavin; Esler, Murray D; Schlaich, Markus P

    2016-01-01

    Renal denervation (RDN) has been shown to reduce blood pressure (BP), muscle sympathetic nerve activity (MSNA) and target organ damage in patients with resistant hypertension (RH) and bilateral single renal arteries. The safety and efficacy of RDN in patients with multiple renal arteries remains unclear. We measured office and 24-hour BP at baseline, 3 and 6 months following RDN in 91 patients with RH, including 65 patients with single renal arteries bilaterally (group 1), 16 patients with dual renal arteries on either one or both sides (group 2) and 10 patients with other anatomical constellations or structural abnormalities (group 3). Thirty nine out of 91 patients completed MSNA at baseline and follow-up. RDN significantly reduced office and daytime SBP in group 1 at both 3 and 6 months follow-up (Pkidney function in any group. While RDN can be performed safely irrespective of the underlying renal anatomy, the presence of single renal arteries with or without structural abnormalities is associated with a more pronounced BP and MSNA lowering effect than the presence of dual renal arteries in patients with RH. However, when patients with dual renal arteries received renal nerve ablation in all arteries there was trend towards a greater BP reduction. Insufficient renal sympathetic nerve ablation may account for these differences. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Influence of arterial wave reflection on carotid blood pressure and intima-media thickness in older endurance trained men and women with pre-hypertension.

    Science.gov (United States)

    Heffernan, Kevin S; Jae, Sae Young; Tomayko, Emily; Ishaque, Muhammad R; Fernhall, Bo; Wilund, Kenneth R

    2009-05-01

    Increased carotid intima-media thickness (IMT) with aging is a significant predictor of mortality. Older endurance trained (ET) individuals have lower carotid artery stiffness but similar carotid IMT when compared to sedentary (SED) age-matched peers. The purpose of this study was to examine the contribution of arterial wave reflections to carotid hemodynamics and IMT in older ET and SED with pre-hypertension. Subjects consisted of endurance-trained master athletes and age-matched sedentary controls (mean age 67 years). Carotid artery Beta-stiffness index and IMT was assessed with ultrasonography. Carotid pressure and augmented pressure from wave reflections (obtained from pulse contour analysis) was measured with applanation tonometry. Carotid systolic blood pressure (SBP) and IMT were not different between groups (P>0.05). Carotid stiffness was significantly lower in ET versus SED (7.3 +/- 0.8 versus 9.9 +/- 0.6, Phypertension have reduced carotid artery stiffness, but similar carotid SBP and carotid IMT when compared to SED. The lack of change in carotid SBP and IMT in older ET may be related to the inability of chronic exercise training to reduce bradycardia-related augmented pressure from wave reflections with aging.

  17. Four-Hour Dives with Exercise While Breathing Oxygen Partial Pressure of 1.3 ATM

    National Research Council Canada - National Science Library

    Shykoff, B

    2006-01-01

    ...) or less but does not address the possible accumulation of effects over multiple days. We have conducted experimental four-hour dives with oxygen partial pressure (Po2) of approximately 1.4 atmospheres (atm...

  18. Three-Hour Dives with Exercise While Breathing Oxygen Partial Pressure of 1.3 ATM

    National Research Council Canada - National Science Library

    Shykoff, B

    2007-01-01

    ...) or less but does not address the possible accumulation of effects over multiple days. When we conducted experimental four-hour dives with oxygen partial pressure (Po2) of approximately 1.4 atmospheres (atm...

  19. Effects of two newly synthesized analogues of lidocaine on rat arterial blood pressure and heart rate.

    Science.gov (United States)

    Al Rasheed, N M; Al Sayed, M I; Al Zuhair, H H; Al Obaid, A R; Fatani, A J

    2001-04-01

    Two new analogues of lidocaine were synthesized at the College of Pharmacy, King Saud University: compound I (Methyl-2-[2-(N,N-diethylamino) acetamido]-3-cyano-4,5-dimethylbenzoate) and compound II (Methyl-2-[2-(piperidino) acetamido]-3-cyano-4,5-dimethylbenzoate). Their influence on the arterial blood pressure and the heart rate of urethane-anaesthetized rats was studied and compared with the actions of lidocaine. Compounds I, II and lidocaine induced significant dose-dependent decreases in the arterial blood pressure and heart rate, which usually returned to basal values within 3-5 min. There were significant differences in the potency of the three compounds in producing their effects on blood pressure and heart rate (Plidocaine and compound I, respectively. The results of this study also indicated the ineffectiveness of antagonists of autonomic, histaminergic and 5-HT receptor, and various vasodilators in blocking the actions of the three compounds on blood pressure and heart rate. Pretreatment with CaCl(2)significantly reduced the hypotension and bradycardia induced by the three compounds, suggesting the involvement of calcium channels, probably of the L type. Several possible mechanisms are postulated. In conclusion, the results direct attention to the capability of the two new compounds to decrease blood pressure and heart rate; affects that may have clinical potential. Copyright 2001 Academic Press.

  20. The change of steel surface chemistry regarding oxygen partial pressure and dew point

    Science.gov (United States)

    Norden, Martin; Blumenau, Marc; Wuttke, Thiemo; Peters, Klaus-Josef

    2013-04-01

    By investigating the surface state of a Ti-IF, TiNb-IF and a MnCr-DP after several series of intercritical annealing, the impact of the annealing gas composition on the selective oxidation process is discussed. On behalf of the presented results, it can be concluded that not the general oxygen partial pressure in the annealing furnace, which is a result of the equilibrium reaction of water and hydrogen, is the main driving force for the selective oxidation process. It is shown that the amounts of adsorbed gases at the strip surface and the effective oxygen partial pressure resulting from the adsorbed gases, which is mainly dependent on the water content of the annealing furnace, is driving the selective oxidation processes occurring during intercritical annealing. Thus it is concluded, that for industrial applications the dew point must be the key parameter value for process control.

  1. Increased arterial compliance in decompensated cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Møller, Søren; Schifter, S

    1999-01-01

    BACKGROUND/AIMS: In patients with cirrhosis, the systemic circulation is hyperdynamic with low arterial blood pressure and reduced systemic vascular resistance. The present study was undertaken to estimate the compliance of the arterial tree in relation to severity of cirrhosis, circulating level...... of the vasodilator, calcitonin gene-related peptide (CGRP) and mean arterial blood pressure (MAP). METHODS: Arterial compliance (COMPart=deltaV/deltaP) was determined as the stroke volume relative to pulse pressure (i.e. systolic minus diastolic blood pressure) during a haemodynamic evaluation of portal hypertension...... of CGRP (r=0.34, pcompliance in cirrhosis is directly related to the severity of the disease and to the elevated level of circulating vasodilator peptide CGRP, and inversely related...

  2. Increased arterial compliance in decompensated cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Møller, Søren; Schifter, S

    1999-01-01

    of the vasodilator, calcitonin gene-related peptide (CGRP) and mean arterial blood pressure (MAP). METHODS: Arterial compliance (COMPart=deltaV/deltaP) was determined as the stroke volume relative to pulse pressure (i.e. systolic minus diastolic blood pressure) during a haemodynamic evaluation of portal hypertension......BACKGROUND/AIMS: In patients with cirrhosis, the systemic circulation is hyperdynamic with low arterial blood pressure and reduced systemic vascular resistance. The present study was undertaken to estimate the compliance of the arterial tree in relation to severity of cirrhosis, circulating level...... of CGRP (r=0.34, parterial compliance in cirrhosis is directly related to the severity of the disease and to the elevated level of circulating vasodilator peptide CGRP, and inversely related...

  3. Soybean oil increases SERCA2a expression and left ventricular contractility in rats without change in arterial blood pressure

    Directory of Open Access Journals (Sweden)

    Vassallo Dalton

    2010-05-01

    Full Text Available Abstract Background Our aim was to evaluate the effects of soybean oil treatment for 15 days on arterial and ventricular pressure, myocardial mechanics and proteins involved in calcium handling. Methods Wistar rats were divided in two groups receiving 100 μL of soybean oil (SB or saline (CT i.m. for 15 days. Ventricular performance was analyzed in male 12-weeks old Wistar rats by measuring left ventricle diastolic and systolic pressure in isolated perfused hearts according to the Langendorff technique. Protein expression was measured by Western blot analysis. Results Systolic and diastolic arterial pressures did not differ between CT and SB rats. However, heart rate was reduced in the SB group. In the perfused hearts, left ventricular isovolumetric systolic pressure was higher in the SB hearts. The inotropic response to extracellular Ca2+ and isoproterenol was higher in the soybean-treated animals than in the control group. Myosin ATPase and Na+-K+ATPase activities, the expression of sarcoplasmic reticulum calcium pump (SERCA2a and sodium calcium exchanger (NCX were increased in the SB group. Although the phosfolamban (PLB expression did not change, its phosphorylation at Ser16 was reduced while the SERCA2a/PLB ratio was increased. Conclusions In summary, soybean treatment for 15 days in rats increases the left ventricular performance without affecting arterial blood pressure. These changes might be associated with an increase in the myosin ATPase activity and SERCA2a expression.

  4. Oxygen supply in aquatic ectotherms: partial pressure and solubility together explain biodiversity and size patterns.

    Science.gov (United States)

    Verberk, Wilco C E P; Bilton, David T; Calosi, Piero; Spicer, John I

    2011-08-01

    Aquatic ectotherms face the continuous challenge of capturing sufficient oxygen from their environment as the diffusion rate of oxygen in water is 3 x 10(5) times lower than in air. Despite the recognized importance of oxygen in shaping aquatic communities, consensus on what drives environmental oxygen availability is lacking. Physiologists emphasize oxygen partial pressure, while ecologists emphasize oxygen solubility, traditionally expressing oxygen in terms of concentrations. To resolve the question of whether partial pressure or solubility limits oxygen supply in nature, we return to first principles and derive an index of oxygen supply from Fick's classic first law of diffusion. This oxygen supply index (OSI) incorporates both partial pressure and solubility. Our OSI successfully explains published patterns in body size and species across environmental clines linked to differences in oxygen partial pressure (altitude, organic pollution) or oxygen solubility (temperature and salinity). Moreover, the OSI was more accurately and consistently related to these ecological patterns than other measures of oxygen (oxygen saturation, dissolved oxygen concentration, biochemical oxygen demand concentrations) and similarly outperformed temperature and altitude, which covaried with these environmental clines. Intriguingly, by incorporating gas diffusion rates, it becomes clear that actually more oxygen is available to an organism in warmer habitats where lower oxygen concentrations would suggest the reverse. Under our model, the observed reductions in aerobic performance in warmer habitats do not arise from lower oxygen concentrations, but instead through organismal oxygen demand exceeding supply. This reappraisal of how organismal thermal physiology and oxygen demands together shape aerobic performance in aquatic ectotherms and the new insight of how these components change with temperature have broad implications for predicting the responses of aquatic communities to

  5. White coat hypertension is more risky than prehypertension: important role of arterial wave reflections.

    Science.gov (United States)

    Sung, Shih-Hsien; Cheng, Hao-Min; Wang, Kang-Ling; Yu, Wen-Chung; Chuang, Shao-Yuan; Ting, Chih-Tai; Lakatta, Edward G; Yin, Frank C P; Chou, Pesus; Chen, Chen-Huan

    2013-06-01

    Arterial aging may link cardiovascular risk to white coat hypertension (WCH). The aims of the present study were to investigate the role of arterial aging in the white coat effect, defined as the difference between office and 24-hour ambulatory systolic blood pressures, and to compare WCH with prehypertension (PH) with respect to target organ damage and long-term cardiovascular mortality. A total of 1257 never-been-treated volunteer subjects from a community-based survey were studied. WCH and PH were defined by office and 24-hour ambulatory blood pressures. Left ventricular mass index, carotid intima-media thickness, estimated glomerular filtration rate, carotid-femoral pulse wave velocity, carotid augmentation index, amplitude of the reflection pressure wave, and 15-year cardiovascular mortality were determined. Subjects with WCH were significantly older and had greater body mass index, blood pressure values, intima-media thickness, carotid-femoral pulse wave velocity, augmentation index, amplitude of the backward pressure wave, and a lower estimated glomerular filtration rate than PH. Amplitude of the backward pressure wave was the most important independent correlate of the white coat effect in multivariate analysis (model r(2)=0.451; partial r(2)/model r(2)=90.5%). WCH had significantly greater cardiovascular mortality than PH (hazard ratio, 2.94; 95% confidence interval, 1.09-7.91), after accounting for age, sex, body mass index, smoking, fasting plasma glucose, and total cholesterol/high-density lipoprotein-cholesterol ratio. Further adjustment of the model for amplitude of the backward pressure wave eliminated the statistical significance of the WCH effect. In conclusion, the white coat effect is mainly caused by arterial aging. WCH carries higher risk for cardiovascular mortality than PH, probably via enhanced wave reflections that accompany arterial aging.

  6. The giraffe kidney tolerates high arterial blood pressure by high renal interstitial pressure and low glomerular filtration rate

    DEFF Research Database (Denmark)

    Damkjær, Mads; Wang, T; Brøndum, E

    2015-01-01

    BACKGROUND: The tallest animal on earth, the giraffe (Giraffa camelopardalis) is endowed with a mean arterial blood pressure (MAP) twice that of other mammals. The kidneys reside at heart level and show no sign of hypertension-related damage. We hypothesized that a species-specific evolutionary...... cava generated a pressure drop of 12 ± 2 mmHg. RI was 0.27. The renal capsule was durable with a calculated burst pressure of 600 mmHg. Plasma renin and AngII were 2.6 ± 0.5 mIU L(-1) and 9.1 ± 1.5 pg mL(-1) respectively. CONCLUSION: In giraffes, GFR, ERPF and RI appear much lower than expected based...... adaption in the giraffe kidney allows normal for size renal haemodynamics and glomerular filtration rate (GFR) despite a MAP double that of other mammals. METHODS: Fourteen anaesthetized giraffes were instrumented with vascular and bladder catheters to measure glomerular filtration rate (GFR) and effective...

  7. Physiological Mechanisms Mediating the Coupling between Heart Period and Arterial Pressure in Response to Postural Changes in Humans

    OpenAIRE

    Silvani, Alessandro; Calandra-Buonaura, Giovanna; Johnson, Blair D.; van Helmond, Noud; Barletta, Giorgio; Cecere, Anna G.; Joyner, Michael J.; Cortelli, Pietro

    2017-01-01

    The upright posture strengthens the coupling between heart period (HP) and systolic arterial pressure (SAP) consistently with a greater contribution of the arterial baroreflex to cardiac control, while paradoxically decreasing cardiac baroreflex sensitivity (cBRS). To investigate the physiological mechanisms that mediate the coupling between HP and SAP in response to different postures, we analyzed the cross-correlation functions between low-frequency HP and SAP fluctuations and estimated cBR...

  8. Does dairy food intake predict arterial stiffness and blood pressure in men?: Evidence from the Caerphilly Prospective Study.

    Science.gov (United States)

    Livingstone, Katherine M; Lovegrove, Julie A; Cockcroft, John R; Elwood, Peter C; Pickering, Janet E; Givens, D Ian

    2013-01-01

    Arterial stiffness is an independent predictor of cardiovascular disease events and mortality, and like blood pressure, may be influenced by dairy food intake. Few studies have investigated the effects of consumption of these foods on prospective measures of arterial stiffness. The present analysis aimed to investigate the prospective relationship between milk, cheese, cream, and butter consumption and aortic pulse wave velocity, augmentation index, systolic and diastolic blood pressure, as well as cross-sectional relationships between these foods and systolic and diastolic blood pressure and metabolic markers using data from the Caerphilly Prospective Study. Included in this cohort were 2512 men, aged 45 to 59 years, who were followed up at 5-year intervals for a mean of 22.8 years (number follow-up 787). Augmentation index was 1.8% lower in subjects in the highest quartiles of dairy product intake compared with the lowest (P trend=0.021), whereas in the highest group of milk consumption systolic blood pressure was 10.4 mm Hg lower (P trend=0.033) than in nonmilk consumers after a 22.8-year follow-up. Cross-sectional analyses indicated that across increasing quartiles of butter intake, insulin (P trend=0.011), triacylglycerol (P trend=0.023), total cholesterol (P trend=0.002), and diastolic blood pressure (P trend=0.027) were higher. Across increasing groups of milk intake and quartiles of dairy product intake, glucose (P trend=0.032) and triglyceride concentrations (P trend=0.031) were lower, respectively. The present results confirm that consumption of milk predicts prospective blood pressure, whereas dairy product consumption, excluding butter, is not detrimental to arterial stiffness and metabolic markers. Further research is needed to better understand the mechanisms that underpin these relationships.

  9. Prevention of Hypoxemia During Apnea Testing: A Comparison of Oxygen Insufflation And Continuous Positive Airway Pressure.

    Science.gov (United States)

    Kramer, Andreas H; Couillard, Philippe; Bader, Ryan; Dhillon, Peter; Kutsogiannis, Demetrios J; Doig, Christopher J

    2017-08-01

    Apnea testing is an essential step in the clinical diagnosis of brain death. Current international guidelines recommend placement of an oxygen (O 2 ) insufflation catheter into the endotracheal tube to prevent hypoxemia, but use of a continuous positive airway pressure (CPAP) valve may be more effective at limiting arterial partial pressure of O 2 (PO 2 ) reduction. We performed a multicenter study assessing consecutive apnea tests in 14 intensive care units (ICUs) in two cities utilizing differing protocols. In one city, O 2 catheters are placed and arterial blood gases (ABGs) performed at intervals determined by the attending physician. In the other city, a resuscitation bag with CPAP valve is attached to the endotracheal tube, and ABGs performed every 3-5 min. We assessed arterial PO 2 , partial pressure of carbon dioxide (PCO 2 ), pH, and blood pressure at the beginning and termination of each apnea test. Thirty-six apnea tests were performed using an O 2 catheter and 50 with a CPAP valve. One test per group was aborted because of physiological instability. There were no significant differences in the degree of PO 2 reduction (-59 vs. -32 mmHg, p = 0.72), rate of PCO 2 rise (3.2 vs. 3.9 mmHg per min, p = 0.22), or pH decline (-0.02 vs. -0.03 per min, p = 0.06). Performance of ABGs at regular intervals was associated with shorter test duration (10 vs. 7 min, p pressure decline (p = 0.006). Both methods of O 2 supplementation are associated with similar changes in arterial PO 2 and PCO 2 . Performance of ABGs at regular intervals shortens apnea test duration and may avoid excessive pH reduction and consequent hemodynamic effects.

  10. The effect of O2 partial pressure on the structure and photocatalytic property of TiO2 films prepared by sputtering

    International Nuclear Information System (INIS)

    Liu Baoshun; Zhao Xiujian; Zhao Qingnan; Li Chunling; He Xin

    2005-01-01

    The TiO 2 films were prepared on slide substrates by dc reactive magnetron sputtering at different oxygen partial pressure, and were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and Fourier transform infrared spectrometry (FT-IR). The degradation of methyl orange aqueous solutions was used to evaluate the photocatalytic activity. The results show that all films show crystalline anatase structure irrespective of oxygen partial pressure. The surface oxygen element exists in three forms, the first one is TiO 2 , the second one is OH - and the last one is physical absorbed water. The films deposited at oxygen partial pressure of 0.035 and 0.040 mTorr present better photocatalytic activity, which shows clear tendency to increase with oxygen partial pressure. Such photocatalytic activity results are considered to correlate with the crystalline structure, grain sizes and the OH - concentration

  11. Systemic arterial hypertension, blood pressure levels and associated factors in schoolchildren

    Directory of Open Access Journals (Sweden)

    Priscila Heleno

    Full Text Available Summary Introduction: Hypertension is a major public health problem in contemporary times and it has high prevalence throughout the world. Objective: To investigate the situation of Systemic Arterial Hypertension in schoolchildren aged 6 to 10 years in Divinópolis/MG-Brazil and associated factors. Method: This is a cross-sectional, epidemiological, descriptive and analytical study, whose population was children aged 6 to 10 years enrolled in public schools in Divinópolis-MG-Brazil. Data collection was conducted from October 2014 to May 2015. Multivariate linear regressions were used to test associations between blood pressure, socioeconomic, anthropometric, dietary and physical activity. Results: The prevalence of hypertension was 15.2% in a sample of 284 children and mean values of systolic blood pressure of 101.7 (±13.2 mmHg and diastolic blood pressure of 66.0 (±11.2 mmHg. The body fat percentage showed significant differences between the genders, with 24.2 and 26.2%, respectively for boys and girls. Significant associations were made between blood pressure levels, body weight, body mass index, waist circumference, body fat percentage, consumption of yogurt, beef /chicken, beans, pizza, sandwich and some behaviors variables. Conclusion: The presented data show important aspects of school profile in the age range 6-10 years, especially related to the behavior of blood pressure.

  12. Results of ambulatory arterial blood pressure monitoring in children with obesity

    Directory of Open Access Journals (Sweden)

    Faruk Öktem

    2010-12-01

    Full Text Available Objectives: The relationship between obesity and essential hypertension is well known. In this study, we aimed to evaluate ambulatory arterial blood pressure monitoring of obese and non-obese children who had similar demographic characteristics.Materials and methods: Seventy one children and adolescents (n=39 obesity, n=32 controls were studied. Blood pressure of the children were measured by 24 hour ambulatory blood pressure monitoring device.Results: Obese children had significantly higher mean blood pressure values (systolic 121.9±11.7 mmHg, diastolic 70.2±5.3 mmHg than control subjects (systolic 109.3±6.7 mmHg, diastolic 65.1±4.6 mmHg, p0.05. Blood pressure load was found to be increased in obese children compared to the controls (%13.6±12.9 and %2.6±3.4, respectively; p<0.05. Serum total cholesterol and LDL-cholesterol levels of obese children (181.1±33.4 and 131.1±23.1mg/dl were significantly higher than those of the controls (134.3±11.1 and 103.3±14.2 mg/dl, p<0.05.Conclusions: Obesity in children and adolescents should not be regarded as variations of normality, but as abnormality with an extremely high risk for the development of hypertension and hyperlipidemia in adulthood.

  13. Partial pressure measurements with an active spectrometer

    International Nuclear Information System (INIS)

    Brooks, N.H.; Jensen, T.H.; Colchin, R.J.; Maingi, R.; Wade, M.R.; Finkenthal, D.F.; Naumenko, N.; Tugarinov, S.

    1998-07-01

    Partial pressure neutral ga measurements have been made using a commercial Penning gauge in conjunction with an active spectrometer. In prior work utilizing bandpass filters and conventional spectrometers, trace concentrations of the hydrogen isotopes H, D, T and of the noble gases He, Ne and Ar were determined from characteristic spectral lines in the light emitted by the neutral species of these elements. For all the elements mentioned, the sensitivity was limited by spectral contamination from a pervasive background of molecular hydrogen radiation. The active spectrometer overcomes this limitations by means of a digital lock-in method and correlation with reference spectra. Preliminary measurements of an admixture containing a trace amount of neon in deuterium show better than a factor of 20 improvement in sensitivity over conventional techniques. This can be further improved by correlating the relative intensities of multiple lines to sets of reference spectra

  14. Relationships Between Components of Blood Pressure and Cardiovascular Events in Patients with Stable Coronary Artery Disease and Hypertension.

    Science.gov (United States)

    Vidal-Petiot, Emmanuelle; Greenlaw, Nicola; Ford, Ian; Ferrari, Roberto; Fox, Kim M; Tardif, Jean-Claude; Tendera, Michal; Parkhomenko, Alexander; Bhatt, Deepak L; Steg, P Gabriel

    2018-01-01

    Observational studies have shown a J-shaped relationship between diastolic blood pressure (BP) and cardiovascular events in hypertensive patients with coronary artery disease. We investigated whether the increased risk associated with low diastolic BP reflects elevated pulse pressure (PP). In 22 672 hypertensive patients with coronary artery disease from the CLARIFY registry (Prospective Observational Longitudinal Registry of Patients With Stable Coronary Artery Disease), followed for a median of 5.0 years, BP was measured annually and averaged. The relationships between PP and diastolic BP, alone or combined, and the primary composite outcome (cardiovascular death or myocardial infarction) were analyzed using multivariable Cox proportional hazards models. Adjusted hazard ratios for the primary outcome were 1.62 (95% confidence interval [CI], 1.40-1.87), 1.00 (ref), 1.07 (95% CI, 0.94-1.21), 1.54 (95% CI, 1.32-1.79), and 2.34 (95% CI, 1.95-2.81) for PPhypertensive patients with coronary artery disease persists in patients within the lowest-risk PP range and is therefore unlikely to be solely the consequence of an increased PP reflecting advanced vascular disease. URL: http://www.clarify-registry.com. Unique identifier: ISRCTN43070564. © 2017 American Heart Association, Inc.

  15. Efficient absorption of SO_2 with low-partial pressures by environmentally benign functional deep eutectic solvents

    International Nuclear Information System (INIS)

    Zhang, Kai; Ren, Shuhang; Hou, Yucui; Wu, Weize

    2017-01-01

    Graphical abstract: Environmentally benign deep eutectic solvents (DESs) based on betaine or L-carnitine with ethylene glycol were designed with a function and used to efficiently capture SO_2 with low partial pressures. - Highlights: • Deep eutectic solvents (DESs) were designed with a function to absorb low-conc. SO_2. • Betaine(Bet) and L-carnitine(L-car) with a functional group were used as H-bond acceptor. • Bet + ethylene glycol (EG) DES and L-car + EG DES are environmentally benign. • L-car + EG DES can absorb 0.644 mol SO_2 per mole L-car (0.37% SO_2). • L-car + EG DES is a promising absorbent for SO_2 capture. - Abstract: Sulfur dioxide (SO_2) emitted from the burning of fossil fuels is one of the main air contaminants. In this work, we found that environmentally benign solvents, deep eutectic solvents (DESs) could be designed with a function to absorb low-partial pressure SO_2 from simulated flue gas. Two kinds of biodegradable functional DESs based on betaine (Bet) and L-carnitine (L-car) as hydrogen bond accepters (HBA) and ethylene glycol (EG) as a hydrogen bond donor (HBD) were prepared with mole ratios of HBA to HBD from 1:3 to 1:5, and they were investigated to absorb SO_2 with different partial pressures at various temperatures. The results showed that the two DESs could absorb low-partial pressure SO_2 efficiently. SO_2 absorption capacities of the DESs with HBA/HBD mole ratio of 1:3 were 0.332 mol SO_2/mol HBA for Bet + EG DES and 0.820 mol SO_2/mol HBA for L-car + EG DES at 40 °C with a SO_2 partial pressure of 0.02 atm. In addition, the regeneration experiments demonstrated that the absorption capacities of DESs did not change after five absorption and desorption cycles. Furthermore, the absorption mechanism of SO_2 by DESs was studied by FT-IR, "1H NMR and "1"3C NMR spectra. It was found that there are strong acid–base interactions between SO_2 and −COO"− on HBA.

  16. Correlation between arterial and venous blood gas analysis parameters in patients with acute exacerbation of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Novović Miloš

    2012-01-01

    Full Text Available Introduction. Arterial blood gas (ABG analyses have an important role in the assessment and monitoring of the metabolic and oxygen status of patients with acute exacerbation of chronic obstructive pulmonary disease (COPD. Arterial puncture could have a lot of adverse effects, while sampling of venous blood is simpler and is not so invasive. Objective. The aim of this study was to evaluate whether venous blood gas (VBG values of pH, partial pressure of carbon dioxide (PCO2, partial oxygen pressure (PO2, bicarbonate (HCO3, and venous and arterial blood oxygen saturation (SO2 can reliably predict ABG levels in patients with acute exacerbation of COPD. Methods. Forty-seven patients with a prior diagnosis of COPD were included in this prospective study. The patients with acute exacerbation of this disease were examined at the General Hospital EMS Department in Prijepolje. ABG samples were taken immediately after venous sampling, and both were analyzed. Results. The Pearson correlation coefficients between arterial and venous parameters were 0.828, 0.877, 0.599, 0.896 and 0.312 for pH, PCO2, PO2, HCO3 and SO2, respectively. The statistically significant correlation between arterial and venous pH, PCO2 and HCO3, values was found in patients with acute exacerbation of COPD (p<0.001. Conclusion. When we cannot provide arterial blood for analysis, venous values of the pH, Pv,CO2 and HCO3 parameters can be an alternative to their arterial equivalents in the interpretation of the metabolic status in patients with acute exacerbation of COPD, while the values of venous Pv,O2 and Sv,O2 cannot be used as predictors in the assessment of oxygen status of such patients.

  17. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Archie Robertson

    2003-10-29

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the July 1--September 30, 2003 time period.

  18. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2003-01-30

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the October 1--December 31, 2002 time period.

  19. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Archie Robertson

    2003-07-23

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the April 1--June 30, 2003 time period.

  20. DEVELOPMENT OF PRESSURIZED CIRCULATIONG FLUIDIZED BED PARTIAL GASIFICATION MODULE(PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Archie Robertson

    2003-04-17

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building block that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the January 1--March 31, 2003 time period.

  1. Development of Pressurized Circulating Fluidized Bed Partial Gasification Module (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    A. Robertson

    2003-12-31

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the October 1 - December 31, 2003 time period.

  2. Sensor for Measuring Hydrogen Partial Pressure in Parabolic Trough Power Plant Expansion Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Glatzmaier, Greg C.; Cooney, Daniel A.

    2017-06-27

    The National Renewable Energy Laboratory and Acciona Energy North America are working together to design and implement a process system that provides a permanent solution to the issue of hydrogen buildup at parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks that serve as reservoirs for the heat transfer fluid (HTF) that circulates in the collector field and power block components. Our modeling shows that removing hydrogen from the expansion tanks at a design rate reduces and maintains dissolved hydrogen in the circulating HTF to a selected target level. Our collaborative work consists of several tasks that are needed to advance this process concept to a development stage, where it is ready for implementation at a commercial power plant. Our main effort is to design and evaluate likely process-unit operations that remove hydrogen from the expansion tanks at a specified rate. Additionally, we designed and demonstrated a method and instrumentation to measure hydrogen partial pressure and concentration in the expansion-tank headspace gas. We measured hydrogen partial pressure in the headspace gas mixture using a palladium-alloy membrane, which is permeable exclusively to hydrogen. The membrane establishes a pure hydrogen gas phase that is in equilibrium with the hydrogen in the gas mixture. We designed and fabricated instrumentation, and demonstrated its effectiveness in measuring hydrogen partial pressures over a range of three orders of magnitude. Our goal is to install this instrument at the Nevada Solar One power plant and to demonstrate its effectiveness in measuring hydrogen levels in the expansion tanks under normal plant operating conditions.

  3. Hydrogen production by the iodine-sulphur thermochemical cycle. Total and partial pressure measurements

    International Nuclear Information System (INIS)

    D Doizi; V Dauvois; J L Roujou; V Delanne; P Fauvet; B Larousse; O Hercher; P Carles; C Moulin

    2006-01-01

    The iodine sulphur thermochemical cycle appears to be one of the most promising candidate for the massive production of hydrogen using nuclear energy. The key step in this cycle is the HI distillation section which must be optimized to get a good efficiency of the overall cycle. The concept of reactive versus extractive distillation of HI has been proposed because of its potentiality. The design and the optimization of the reactive distillation column requires the knowledge of the liquid vapour equilibrium over the ternary HI-I 2 -H 2 O mixtures up to 300 C and 100 bars. A general methodology based on three experimental devices imposed by the very corrosive and concentrated media will be described: 1) I1 for the total pressure measurement versus different ternary compositions. 2) I2 for the partial and total pressure measurements around 130 C and 2 bars to validate the choice of the analytical optical 'online' techniques we have proposed. 3) I3 for the partial and total pressures measurements in the process domain. The results obtained on pure samples, binary mixtures HI-H 2 O and ternary mixtures using an experimental design analysis in the experimental device I2 will be discussed. (authors)

  4. Relationship between chronic intermittent hypoxia and intraoperative mean arterial pressure in obstructive sleep apnea patients having laparoscopic bariatric surgery.

    Science.gov (United States)

    Turan, Alparslan; You, Jing; Egan, Cameron; Fu, Alex; Gazmuri, Ignazia; Khanna, Ashish; Eshraghi, Yashar; Ghosh, Raktim; Bose, Somnath; Qavi, Shahbaz; Arora, Lovkesh; Sessler, Daniel I; Doufas, Anthony G

    2015-01-01

    Recurrent nocturnal hypoxemia in obstructive sleep apnea enhances sympathetic function, decreases baroreceptor sensitivity, and weakens peripheral vascular responses to adrenergic signals. The authors hypothesized that the percentage of total sleep time spent at oxyhemoglobin saturation (SaO2) less than 90% and minimum nocturnal SaO2 on preoperative polysomnography are associated with decreased intraoperative mean arterial pressure. The authors examined the records of all patients who had laparoscopic bariatric surgery at Cleveland Clinic between 2005 and 2009 and an available polysomnography study. The authors assessed the relationships between the percentage of total sleep time spent at SaO2 less than 90% and minimum nocturnal SaO2, and the time-weighted average of mean arterial pressure. The authors used multivariable regression models to adjust for prespecified clinical confounders. Two hundred eighty-one patients were included in the analysis. The average change in the time-weighted average of mean arterial pressure was -0.02 (97.5% CI, -0.08, 0.04) mmHg for each 1% absolute increase in the percentage of sleep time spent at SaO2 less than 90% (P = 0.50). The average change was -0.13 (97.5% CI, -0.27, 0.01) mmHg, for each 1% absolute decrease in the minimum SaO2 (P = 0.04 > significance criterion of 0.025, Bonferroni correction). An unplanned analysis estimated 1% absolute decrease in minimum SaO2 was associated with -0.22 (98.75% CI, -0.39, -0.04) mmHg, change in mean arterial pressure (P = 0.002) in the time period between endotracheal intubation and trocar insertion. Recurrent nocturnal hypoxemia in obstructive sleep apnea is not a risk marker for intraoperative hypotension.

  5. Partial volume effect (PVE) on the arterial input function (AIF) in T1-weighted perfusion imaging and limitations of the multiplicative rescaling approach

    DEFF Research Database (Denmark)

    Hansen, Adam Espe; Pedersen, Henrik; Rostrup, Egill

    2009-01-01

    The partial volume effect (PVE) on the arterial input function (AIF) remains a major obstacle to absolute quantification of cerebral blood flow (CBF) using MRI. This study evaluates the validity and performance of a commonly used multiplicative rescaling of the AIF to correct for the PVE. In a gr...

  6. Peripheral Chemoreception and Arterial Pressure Responses to Intermittent Hypoxia

    Science.gov (United States)

    Prabhakar, Nanduri R.; Peng, Ying-Jie; Kumar, Ganesh K.; Nanduri, Jayasri

    2015-01-01

    Carotid bodies are the principal peripheral chemoreceptors for detecting changes in arterial blood oxygen levels, and the resulting chemoreflex is a potent regulator of blood pressure. Recurrent apnea with intermittent hypoxia (IH) is a major clinical problem in adult humans and infants born preterm. Adult patients with recurrent apnea exhibit heightened sympathetic nerve activity and hypertension. Adults born preterm are predisposed to early onset of hypertension. Available evidence suggests that carotid body chemoreflex contributes to hypertension caused by IH in both adults and neonates. Experimental models of IH provided important insights into cellular and molecular mechanisms underlying carotid body chemoreflex-mediated hypertension. This article provides a comprehensive appraisal of how IH affects carotid body function, underlying cellular, molecular, and epigenetic mechanisms, and the contribution of chemoreflex to the hypertension. PMID:25880505

  7. Peripheral chemoreception and arterial pressure responses to intermittent hypoxia.

    Science.gov (United States)

    Prabhakar, Nanduri R; Peng, Ying-Jie; Kumar, Ganesh K; Nanduri, Jayasri

    2015-04-01

    Carotid bodies are the principal peripheral chemoreceptors for detecting changes in arterial blood oxygen levels, and the resulting chemoreflex is a potent regulator of blood pressure. Recurrent apnea with intermittent hypoxia (IH) is a major clinical problem in adult humans and infants born preterm. Adult patients with recurrent apnea exhibit heightened sympathetic nerve activity and hypertension. Adults born preterm are predisposed to early onset of hypertension. Available evidence suggests that carotid body chemoreflex contributes to hypertension caused by IH in both adults and neonates. Experimental models of IH provided important insights into cellular and molecular mechanisms underlying carotid body chemoreflex-mediated hypertension. This article provides a comprehensive appraisal of how IH affects carotid body function, underlying cellular, molecular, and epigenetic mechanisms, and the contribution of chemoreflex to the hypertension. © 2015 American Physiological Society.

  8. EFFECT OF LISINOPRIL ON 24-HOUR BLOOD PRESSURE AND ARTERIAL STIFFNESS IN PATIENTS WITH ARTERIAL HYPERTENSION AND RHEUMATOID ARTHRITIS

    Directory of Open Access Journals (Sweden)

    O. L. Sarkisova

    2017-01-01

    Full Text Available Aim. To study effect of 24-week treatment with lisinopril on blood pressure (BP and arterial stiffness in patients with arterial hypertension (HT and rheumatoid arthritis (RA.Material and methods. Twenty patients with essential HT grade  1-2 and RA (mean age 60.2±7.9 years were treated with lisinoprilin 24 weeks in open controlled study. Office blood pressure (BP was 147.2±9.4/87.5±8.6 mm Hg; 24-h mean  BP – 141.8±9.3/82.2±9.6 mm Hg; HT duration was 14.5±9.4 years, and RA duration – 12.3±2.6 years. A high incidence of traditional cardiovascular risk factors was identified: 95% of patients had dyslipidaemia, 45% – obesity, 35% – impaired glucose tolerance. Atherosclerosis of carotid arteries with stenosis less than 25% was diagnosed in 65% of patients. Most patients had a positive rheumatoid factor and cyclic citrullinated peptide antibodies, as well as moderate RA activity and III-IV radiologic stage of RA. All patients received methotrexate as the basic anti-inflammatory drug, 12 (60% patients – selective cyclooxygenase-2 inhibitors, 6 (30% patients took corticosteroids equivalent to prednisolone 7.5±5.5 mg per day. Mean  dose  of lisinopril was 12.2±9.8 mg/day. Office BP measurements, 24-hour ambulatory BP monitoring (ABPM, and  arterial stiffness evaluation were  performed initially and  at the end of the study. Arterial stiffness was assessed by cardio-ankle vascular index on the right (R-CAVI and on the left (L-CAVI.Results. After 24-week therapy with lisinopril office systolic and diastolic BP significantly decreased by 16.0±7.2/11.6±9.1 mm Hg (p<0.0001 and 11.6±9.1 mm Hg (p<0.0001, respectively. The target BP was achieved in 16 (83% patients. According to the ABPM 24-week therapy with lisino pril led to a significant (p<0.002 decrease in BP for all referable periods: by 12.4±9.1/7.6±3.9 mm Hg within 24 hours;  by 13.4±10.1/8.0±6.1 mm Hg for daytime; by 10.1±9.3/7.3±6.3 mm Hg for night-time. After

  9. Effects of an alveolar recruitment maneuver on subdural pressure, brain swelling, and mean arterial pressure in patients undergoing supratentorial tumour resection: a randomized crossover study.

    Science.gov (United States)

    Flexman, Alana M; Gooderham, Peter A; Griesdale, Donald E; Argue, Ruth; Toyota, Brian

    2017-06-01

    Although recruitment maneuvers have been advocated as part of a lung protective ventilation strategy, their effects on cerebral physiology during elective neurosurgery are unknown. Our objectives were to determine the effects of an alveolar recruitment maneuver on subdural pressure (SDP), brain relaxation score (BRS), and cerebral perfusion pressure among patients undergoing supratentorial tumour resection. In this prospective crossover study, patients scheduled for resection of a supratentorial brain tumour were randomized to undergo either a recruitment maneuver (30 cm of water for 30 sec) or a "sham" maneuver (5 cm of water for 30 sec), followed by the alternative intervention after a 90-sec equilibration period. Subdural pressure was measured through a dural perforation following opening of the cranium. Subdural pressure and mean arterial pressure (MAP) were recorded continuously. The blinded neurosurgeon provided a BRS at baseline and at the end of each intervention. During each treatment, the changes in SDP, BRS, and MAP were compared. Twenty-one patients underwent the study procedure. The increase in SDP was higher during the recruitment maneuver than during the sham maneuver (difference, 3.9 mmHg; 95% confidence interval [CI], 2.2 to 5.6; P < 0.001). Mean arterial pressure decreased further in the recruitment maneuver than in the sham maneuver (difference, -9.0 mmHg; 95% CI, -12.5 to -5.6; P < 0.001). Cerebral perfusion pressure decreased 14 mmHg (95% CI, 4 to 24) during the recruitment maneuver. The BRS did not change with either maneuver. Our results suggest that recruitment maneuvers increase subdural pressure and reduce cerebral perfusion pressure, although the clinical importance of these findings is thus far unknown. This trial was registered with ClinicalTrials.gov, NCT02093117.

  10. A micromechanical device that monitors arterial pressure during general anesthesia and in intensive care units

    Science.gov (United States)

    Andreeva, A. V.; Luchinin, V. V.; Kuzmina, K. A.; Klyavinek, A. S.; Karelov, A. E.

    2015-12-01

    A vibroacoustic fiber optic system that consists of micromechanical components designated for use in medicine and biology is reviewed. A theoretical analysis of a fiber optic microphone is done and its optimal construction parameters are determined. The possibility of using the developed system with magnetic resonance tomography to noninvasively measure man's arterial pressure is specified.

  11. Partial alignment and measurement of residual dipolar couplings of proteins under high hydrostatic pressure

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yinan; Wand, A. Joshua, E-mail: wand@mail.med.upenn.edu [University of Pennsylvania, Department of Biochemistry and Biophysics, Johnson Research Foundation (United States)

    2013-08-15

    High-pressure NMR spectroscopy has emerged as a complementary approach for investigating various structural and thermodynamic properties of macromolecules. Noticeably absent from the array of experimental restraints that have been employed to characterize protein structures at high hydrostatic pressure is the residual dipolar coupling, which requires the partial alignment of the macromolecule of interest. Here we examine five alignment media that are commonly used at ambient pressure for this purpose. We find that the spontaneous alignment of Pf1 phage, d(GpG) and a C12E5/n-hexnanol mixture in a magnetic field is preserved under high hydrostatic pressure. However, DMPC/DHPC bicelles and collagen gel are found to be unsuitable. Evidence is presented to demonstrate that pressure-induced structural changes can be identified using the residual dipolar coupling.

  12. Structural, mechanical, electrical and wetting properties of ZrNx films deposited by Ar/N2 vacuum arc discharge: Effect of nitrogen partial pressure

    Science.gov (United States)

    Abdallah, B.; Naddaf, M.; A-Kharroub, M.

    2013-03-01

    Non-stiochiometric zirconium nitride (ZrNx) thin films have been deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures at different N2 partial pressure ratio. The microstructure, mechanical, electrical and wetting properties of these films are studied by means of X-ray diffraction (XRD), micro-Raman spectroscopy, Rutherford back scattering (RBS) technique, conventional micro-hardness testing, electrical resistivity, atomic force microscopy (AFM) and contact angle (CA) measurements. RBS results and analysis show that the (N/Zr) ratio in the film increases with increasing the N2 partial pressure. A ZrNx film with (Zr/N) ratio in the vicinity of stoichiometric ZrN is obtained at N2 partial pressure of 10%. XRD and Raman results indicate that all deposited films have strained cubic crystal phase of ZrN, regardless of the N2 partial pressure. On increasing the N2 partial pressure, the relative intensity of (1 1 1) orientation with respect to (2 0 0) orientation is seen to decrease. The effect of N2 partial pressure on micro-hardness and the resistivity of the deposited film is revealed and correlated to the alteration of grain size, crystallographic texture, stoichiometry and residual stress developed in the film. In particular, it is found that residual stress and nitrogen incorporation in the film play crucial role in the alteration of micro-hardness and resistivity respectively. In addition, CA and AFM results demonstrate that as N2 partial pressure increases, both the surface hydrophobicity and roughness of the deposited film increase, leading to a significant decrease in the film surface free energy (SFE).

  13. Vascular reactivity of mesenteric arteries and veins to endothelin-1 in a murine model of high blood pressure.

    Science.gov (United States)

    Pérez-Rivera, Alex A; Fink, Gregory D; Galligan, James J

    2005-06-01

    We characterized vascular reactivity to endothelin-1 (ET-1) in mesenteric vessels from DOCA-salt hypertensive and SHAM control mice and assessed the effect that endothelial-derived vasodilators have on ET-1-induced vasoconstriction. Changes in the diameter of unpressurized small mesenteric arteries and veins (100- to 300-microm outside diameter) were measured in vitro using computer-assisted video microscopy. Veins were more sensitive than arteries to the contractile effects of ET-1. There was a decrease in arterial maximal responses (E(max)) compared to veins, this effect was larger in DOCA-salt arteries. The selective ET(B) receptor agonist, sarafotoxin 6c (S6c), contracted DOCA-salt and SHAM veins but did not contract arteries. The ET(B) receptor antagonist, BQ-788 (100 nM), but not the ET(A) receptor antagonist, BQ-610 (100 nM), blocked S6c responses. BQ-610 partially inhibited responses to ET-1 in mesenteric veins from DOCA-salt and SHAM mice while BQ-788 did not affect responses to ET-1. Co-administration of both antagonists inhibited responses to ET-1 to a greater extent than BQ-610 alone suggesting a possible functional interaction between ET(A) and ET(B) receptors. Responses to ET-1 in mesenteric arteries were completely inhibited by BQ-610 while BQ-788 did not affect arterial responses. Nitric oxide synthase inhibition potentiated ET-1 responses in veins from SHAM but not DOCA-salt mice. There was a prominent role for ET-mediated nitric oxide release in DOCA-salt but not SHAM arteries. In summary, these studies showed a differential regulation of ET-1 contractile mechanisms between murine mesenteric arteries and veins.

  14. Ambulatory (24 h) blood pressure and arterial stiffness measurement in Marfan syndrome patients: a case control feasibility and pilot study.

    Science.gov (United States)

    Hillebrand, Matthias; Nouri, Ghazaleh; Hametner, Bernhard; Parragh, Stephanie; Köster, Jelena; Mortensen, Kai; Schwarz, Achim; von Kodolitsch, Yskert; Wassertheurer, Siegfried

    2016-05-06

    The aim of this work is the investigation of measures of ambulatory brachial and aortic blood pressure and indices of arterial stiffness and aortic wave reflection in Marfan patients. A case-control study was conducted including patients with diagnosed Marfan syndrome following Ghent2 nosology and healthy controls matched for sex, age and daytime brachial systolic blood pressure. For each subject a 24 h ambulatory blood pressure and 24 h pulse wave analysis measurement was performed. All parameters showed a circadian pattern whereby pressure dipping was more pronounced in Marfan patients. During daytime only Marfan patients with aortic root surgery showed increased pulse wave velocity. In contrast, various nighttime measurements, wave reflection determinants and circadian patterns showed a significant difference. The findings of our study provide evidence that ambulatory measurement of arterial stiffness parameters is feasible and that these determinants are significantly different in Marfan syndrome patients compared to controls in particular at nighttime. Further investigation is therefore indicated.

  15. Blood pressure regulation V: in vivo mechanical properties of precapillary vessels as affected by long-term pressure loading and unloading.

    Science.gov (United States)

    Eiken, Ola; Mekjavic, Igor B; Kölegård, Roger

    2014-03-01

    Recent studies are reviewed, concerning the in vivo wall stiffness of arteries and arterioles in healthy humans, and how these properties adapt to iterative increments or sustained reductions in local intravascular pressure. A novel technique was used, by which arterial and arteriolar stiffness was determined as changes in arterial diameter and flow, respectively, during graded increments in distending pressure in the blood vessels of an arm or a leg. Pressure-induced increases in diameter and flow were smaller in the lower leg than in the arm, indicating greater stiffness in the arteries/arterioles of the leg. A 5-week period of intermittent intravascular pressure elevations in one arm reduced pressure distension and pressure-induced flow in the brachial artery by about 50%. Conversely, prolonged reduction of arterial/arteriolar pressure in the lower body by 5 weeks of sustained horizontal bedrest, induced threefold increases of the pressure-distension and pressure-flow responses in a tibial artery. Thus, the wall stiffness of arteries and arterioles are plastic properties that readily adapt to changes in the prevailing local intravascular pressure. The discussion concerns mechanisms underlying changes in local arterial/arteriolar stiffness as well as whether stiffness is altered by changes in myogenic tone and/or wall structure. As regards implications, regulation of local arterial/arteriolar stiffness may facilitate control of arterial pressure in erect posture and conditions of exaggerated intravascular pressure gradients. That increased intravascular pressure leads to increased arteriolar wall stiffness also supports the notion that local pressure loading may constitute a prime mover in the development of vascular changes in hypertension.

  16. Influence of geomagnetic activity and atmospheric pressure on human arterial pressure during the solar cycle 24

    Science.gov (United States)

    Azcárate, T.; Mendoza, B.; Levi, J. R.

    2016-11-01

    We performed a study of the systolic (SBP) and diastolic (DBP) arterial blood pressure behavior under natural variables such as the atmospheric pressure (AtmP) and the horizontal geomagnetic field component (H). We worked with a sample of 304 healthy normotense volunteers, 152 men and 152 women, with ages between 18 and 84 years in Mexico City during the period 2008-2014, corresponding to the minimum, ascending and maximum phases of the solar cycle 24. The data was divided by gender, age and day/night cycle. We studied the time series using three methods: Correlations, bivariate and superposed epochs (within a window of three days around the day of occurrence of a geomagnetic storm) analysis, between the SBP and DBP and the natural variables (AtmP and H). The correlation analysis indicated correlation between the SBP and DBP and AtmP and H, being the largest during the night. Furthermore, the correlation and bivariate analysis showed that the largest correlations are between the SBP and DBP and the AtmP. The superposed epoch analysis found that the largest number of significant SBP and DBP changes occurred for women. Finally, the blood pressure changes are larger during the solar minimum and ascending solar cycle phases than during the solar maximum; the storms of the minimum were more intense than those of the maximum and this could be the reason of behavior of the blood pressure changes along the solar cycle.

  17. Role of the medulla oblongata in normal and high arterial blood pressure regulation: the contribution of Escola Paulista de Medicina - UNIFESP.

    Science.gov (United States)

    Cravo, Sergio L; Campos, Ruy R; Colombari, Eduardo; Sato, Mônica A; Bergamaschi, Cássia M; Pedrino, Gustavo R; Ferreira-Neto, Marcos L; Lopes, Oswaldo U

    2009-09-01

    Several forms of experimental evidence gathered in the last 37 years have unequivocally established that the medulla oblongata harbors the main neural circuits responsible for generating the vasomotor tone and regulating arterial blood pressure. Our current understanding of this circuitry derives mainly from the studies of Pedro Guertzenstein, a former student who became Professor of Physiology at UNIFESP later, and his colleagues. In this review, we have summarized the main findings as well as our collaboration to a further understanding of the ventrolateral medulla and the control of arterial blood pressure under normal and pathological conditions.

  18. Measurement of brachial artery endothelial function using a standard blood pressure cuff

    International Nuclear Information System (INIS)

    Maltz, Jonathan S; Budinger, Thomas F; Tison, Geoffrey H; Olgin, Jeffrey; Alley, Hugh F; Owens, Christopher D

    2015-01-01

    The integrity of endothelial function in major arteries (EFMA) is a powerful independent predictor of heart attack and stroke. Existing ultrasound-based non-invasive assessment methods are technically challenging and suitable only for laboratory settings. EFMA, like blood pressure (BP), is both acutely and chronically affected by factors such as lifestyle and medication. Consequently, laboratory-based measurements cannot fully gauge the effects of medical interventions on EFMA. EFMA and BP have, arguably, comparable (but complementary) value in the assessment of cardiovascular health. Widespread deployment of EFMA assessment is thus a desirable clinical goal. To this end, we propose a device based on modifying the measurement protocol of a standard electronic sphygmomanometer. The protocol involves inflating the cuff to sub-diastolic levels to enable recording of the pulse waveform before and after vasodilatory stimulus. The mechanical unloading of the arterial wall provided by the cuff amplifies the distension that occurs with each pulse, which is measured as a pressure variation in the cuff. We show that the height of the rising edge of each pulse is proportional to the change in lumen area between diastole and systole. This allows the effect of vasodilatory stimuli on the artery to be measured with high sensitivity. We compare the proposed cuff flow-mediated dilation (cFMD) method to ultrasound flow-mediated dilation (uFMD). We find significant correlation (r  =  0.55, p  =0.003, N  =  27) between cFMD- and uFMD-based metrics obtained when the release of a 5 min cuff occlusion is employed to induce endothelial stimulus via reactive hyperemia. cFMD is approximately proportional to the square of uFMD, representing a typical increase in sensitivity to vasodilation of 300–600%. This study illustrates the potential for an individual to conveniently measure his/her EFMA by using a low-cost reprogrammed home sphygmomanometer. (paper)

  19. Influence of short-term blood pressure variability on blood pressure determinations

    NARCIS (Netherlands)

    Bos, W. J.; van Goudoever, J.; van Montfrans, G. A.; Wesseling, K. H.

    1992-01-01

    To evaluate the effect of blood pressure variability on Riva Rocci Korotkoff blood pressure determinations, we studied the intra-arterial pressure during Riva Rocci Korotkoff determinations in 25 patients. In 50 measurements with a cuff deflation rate of 2.5 mm Hg/sec, the systolic intra-arterial

  20. Association of vitamin D status with arterial blood pressure and hypertension risk

    DEFF Research Database (Denmark)

    Vimaleswaran, Karani S; Cavadino, Alana; Berry, Diane J

    2014-01-01

    BACKGROUND: Low plasma 25-hydroxyvitamin D (25[OH]D) concentration is associated with high arterial blood pressure and hypertension risk, but whether this association is causal is unknown. We used a mendelian randomisation approach to test whether 25(OH)D concentration is causally associated...... with blood pressure and hypertension risk. METHODS: In this mendelian randomisation study, we generated an allele score (25[OH]D synthesis score) based on variants of genes that affect 25(OH)D synthesis or substrate availability (CYP2R1 and DHCR7), which we used as a proxy for 25(OH)D concentration. We meta......, -0·12 mm Hg, 95% CI -0·20 to -0·04; p=0·003) and reduced odds of hypertension (odds ratio [OR] 0·98, 95% CI 0·97-0·99; p=0·0003), but not with decreased diastolic blood pressure (β per 10% increase, -0·02 mm Hg, -0·08 to 0·03; p=0·37). In meta-analyses in which we combined data from D...

  1. Cathodic over-potential and hydrogen partial pressure coupling in hydrogen evolution reaction of marine steel under hydrostatic pressure

    International Nuclear Information System (INIS)

    Xiong, X.L.; Zhou, Q.J.; Li, J.X.; Volinsky, Alex A.; Su, Y.J.

    2017-01-01

    Highlights: •Hydrostatic pressure increases the Volmer and the Heyrovsky reactions rates. •Hydrostatic pressure decreases the Tafel reaction rate. •Hydrogen adsorption conditions change with pressure under −1.2 and −1.3 V SSE . •Under −1.2 and −1.3 V SSE , the Heyrovsky reaction dominates the hydrogen recombination. •Under −1.0 and −1.1 V SSE , the Tafel reaction dominates the hydrogen recombination. -- Abstract: A new electrochemical impedance spectroscopy (EIS) model, which considers both the Tafel recombination and the Heyrovsky reaction under permeable boundary conditions, was developed to characterize the kinetic parameters of the hydrogen evolution reaction (HER) under hydrostatic pressure. The effect of the hydrostatic pressure on the kinetic parameters of the HER and the permeation of A514 steel in alkaline solution were measured using potentiodynamic polarization, the Devanathan cell hydrogen permeation, and EIS. The hydrostatic pressure accelerates the Volmer reaction and inhibits the Tafel recombination, which increases the number of adsorbed hydrogen atoms. On the other hand, the pressure accelerates the Heyrovsky reaction, which decreases the amount of adsorbed hydrogen atoms. At 10 to 40 MPa hydrostatic pressure within the −1.0 to −1.1 V SSE cathodic potential region, the HER is controlled by hydrogen partial pressure, and hydrogen adsorption is the Langmuir type. Within the −1.2 to −1.3 V SSE cathodic potential region, the HER is controlled by the potential, and hydrogen adsorption gradually transfers from the Langmuir type to the Temkin type with increasing hydrostatic pressure.

  2. Influence of N2 partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N2 vacuum arc discharge

    Science.gov (United States)

    Naddaf, M.; Abdallah, B.; Ahmad, M.; A-Kharroub, M.

    2016-08-01

    The influence of N2 partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N2 partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N2 partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N2 partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N2 partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N2 partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N2 partial pressure.

  3. Influence of N_2 partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N_2 vacuum arc discharge

    International Nuclear Information System (INIS)

    Naddaf, M.; Abdallah, B.; Ahmad, M.; A-Kharroub, M.

    2016-01-01

    The influence of N_2 partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N_2 + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N_2 partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N_2 partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N_2 partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N_2 partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N_2 partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N_2 partial pressure.

  4. Effect of the addition of vasopressin or vasopressin plus nitroglycerin to epinephrine on arterial blood pressure during cardiopulmonary resuscitation in humans.

    Science.gov (United States)

    Ducros, Laurent; Vicaut, Eric; Soleil, Christian; Le Guen, Morgan; Gueye, Papa; Poussant, Thomas; Mebazaa, Alexandre; Payen, Didier; Plaisance, Patrick

    2011-11-01

    Infusion of a vasopressor during cardiopulmonary resuscitation (CPR) in humans increases end decompression (diastolic) arterial blood pressure, and consequently increases vital organ perfusion pressure and survival. Several vasoactive drugs have been tested alone or in combination, but their hemodynamic effects have not been investigated clinically in humans. We tested the hypothesis that epinephrine (1 mg) co-administered with vasopressin (40 IU) ± nitroglycerin (300 μg) results in higher diastolic blood pressure than epinephrine alone. A prospective, randomized, double-blinded controlled trial in the prehospital setting. The study included 48 patients with witnessed cardiac arrest. Patients received either epinephrine alone (E alone) or epinephrine plus vasopressin (E+V) or epinephrine plus vasopressin plus nitroglycerin (E+V+N). A femoral arterial catheter was inserted for arterial pressure measurement. The primary end point was diastolic blood pressure during CPR, 15 min after the first drug administration (T = 15 min). After exclusions, a total of 44 patients were enrolled. Diastolic blood pressures (mm Hg) at T = 15 min were not statistically different between groups (median [interquartile range]: 20 [10], 15 [6], and 15 [13] for E alone, E+V, and E+V+N, respectively. The rate of return of spontaneous circulation was 63% (n = 10) in the epinephrine group, 43% (n = 6) in the epinephrine plus vasopressin group, and 36% (n = 5) in the triple therapy group (NS). Addition of vasopressin or vasopressin plus nitroglycerin to epinephrine did not increase perfusion blood pressure compared to epinephrine alone in humans in cardiac arrest, suggesting the absence of benefit in using these drug combination(s). Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Avaliação da pressão arterial em bombeiros militares filhos de hipertensos através da monitorização ambulatorial da pressão arterial Using ambulatory blood pressure monitoring to assess blood pressure of firefighters with parental history of hypertension

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo de Mattos

    2006-12-01

    Full Text Available OBJETIVO: Avaliar a influência do antecedente familiar de hipertensão arterial sistêmica (HASF sobre o efeito do estresse do trabalho em bombeiros militares comunicantes (BMC, através da monitorização ambulatorial da pressão arterial (MAPA. MÉTODOS: Estudo prospectivo caso-controle. Foi realizada a MAPA em 66 BMC saudáveis, durante 12 horas de trabalho na central de comunicações (CC, sendo 34 filhos de hipertensos (grupo 1 e 32 filhos de normotensos (grupo 2. RESULTADOS: O grupo 1 diferiu do grupo 2, pois apresentou, no trabalho, maiores médias sistólicas (134,1 ± 9,9 mmHg X 120,8 ± 9,9 mmHg p OBJECTIVE: To evaluate the influence of family history of systemic arterial hypertension (FSAH on the effect of stress from work in Uniformed Firefighters (BMCs through Ambulatory Blood Pressure Monitoring (ABPM. METHODS: A prospective case-control study. Sixty-six healthy BMC underwent ABPM during 12 hours of work at the Communication Center (CC. Thirty-four had hypertensive parents (group 1 and thirty-two had normotensive parents (group 2. RESULTS: Group I differed from group 2 in that it showed higher mean systolic (134.1 ± 9.9 mmHg X 120.8 ± 9.9 mmHg p < 0.0001 and diastolic (83.8 ± 8.3 mmHg X 72.9 ± 8.6 mmHg p < 0.001 blood pressure, in addition to greater systolic (31.4 ± 25.6 % X 9.4 ± 9.4 % p = 0.0001 and diastolic (28.3 ± 26.6 % X 6.1 ± 8.9 % p = 0.0001 loads. The prevalence of systemic arterial hypertension (SAH in group 1 at the workplace was 32.3%. Monitored away from the job, these subjects showed normal blood pressure (functionally hypertensive. Group 2 revealed normal blood pressure (BP at work. CONCLUSION: Higher blood pressure in BMC with hypertensive parents is explained independently by the SAH. Subjects who developed SAH during their work at the CC may be considered functionally hypertensive, whereas those with normotensive parents and who underwent psychological stress are free of blood pressure changes.

  6. Efficient absorption of SO{sub 2} with low-partial pressures by environmentally benign functional deep eutectic solvents

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kai; Ren, Shuhang [State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029 (China); Hou, Yucui [Department of Chemistry, Taiyuan Normal University, Taiyuan, 030031 (China); Wu, Weize, E-mail: wzwu@mail.buct.edu.cn [State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029 (China)

    2017-02-15

    Graphical abstract: Environmentally benign deep eutectic solvents (DESs) based on betaine or L-carnitine with ethylene glycol were designed with a function and used to efficiently capture SO{sub 2} with low partial pressures. - Highlights: • Deep eutectic solvents (DESs) were designed with a function to absorb low-conc. SO{sub 2}. • Betaine(Bet) and L-carnitine(L-car) with a functional group were used as H-bond acceptor. • Bet + ethylene glycol (EG) DES and L-car + EG DES are environmentally benign. • L-car + EG DES can absorb 0.644 mol SO{sub 2} per mole L-car (0.37% SO{sub 2}). • L-car + EG DES is a promising absorbent for SO{sub 2} capture. - Abstract: Sulfur dioxide (SO{sub 2}) emitted from the burning of fossil fuels is one of the main air contaminants. In this work, we found that environmentally benign solvents, deep eutectic solvents (DESs) could be designed with a function to absorb low-partial pressure SO{sub 2} from simulated flue gas. Two kinds of biodegradable functional DESs based on betaine (Bet) and L-carnitine (L-car) as hydrogen bond accepters (HBA) and ethylene glycol (EG) as a hydrogen bond donor (HBD) were prepared with mole ratios of HBA to HBD from 1:3 to 1:5, and they were investigated to absorb SO{sub 2} with different partial pressures at various temperatures. The results showed that the two DESs could absorb low-partial pressure SO{sub 2} efficiently. SO{sub 2} absorption capacities of the DESs with HBA/HBD mole ratio of 1:3 were 0.332 mol SO{sub 2}/mol HBA for Bet + EG DES and 0.820 mol SO{sub 2}/mol HBA for L-car + EG DES at 40 °C with a SO{sub 2} partial pressure of 0.02 atm. In addition, the regeneration experiments demonstrated that the absorption capacities of DESs did not change after five absorption and desorption cycles. Furthermore, the absorption mechanism of SO{sub 2} by DESs was studied by FT-IR, {sup 1}H NMR and {sup 13}C NMR spectra. It was found that there are strong acid–base interactions between SO{sub 2} and

  7. Real-Time Monitoring of Singlet Oxygen and Oxygen Partial Pressure During the Deep Photodynamic Therapy In Vitro.

    Science.gov (United States)

    Li, Weitao; Huang, Dong; Zhang, Yan; Liu, Yangyang; Gu, Yueqing; Qian, Zhiyu

    2016-09-01

    Photodynamic therapy (PDT) is an effective noninvasive method for the tumor treatment. The major challenge in current PDT research is how to quantitatively evaluate therapy effects. To our best knowledge, this is the first time to combine multi-parameter detection methods in PDT. More specifically, we have developed a set of system, including the high-sensitivity measurement of singlet oxygen, oxygen partial pressure and fluorescence image. In this paper, the detection ability of the system was validated by the different concentrations of carbon quantum dots. Moreover, the correlation between singlet oxygen and oxygen partial pressure with laser irradiation was observed. Then, the system could detect the signal up to 0.5 cm tissue depth with 660 nm irradiation and 1 cm tissue depth with 980 nm irradiation by using up-conversion nanoparticles during PDT in vitro. Furthermore, we obtained the relationship among concentration of singlet oxygen, oxygen partial pressure and tumor cell viability under certain conditions. The results indicate that the multi-parameter detection system is a promising asset to evaluate the deep tumor therapy during PDT. Moreover, the system might be potentially used for the further study in biology and molecular imaging.

  8. Does intact pleura during internal mammary artery harvesting decreases pleuropulmonary complications

    International Nuclear Information System (INIS)

    Paracha, V.I.; Iqbal, M.A.; Rashid, A.

    2011-01-01

    Objective: To evaluate the effects on postoperative pulmonary function of pleural integrity versus opened pleura, in patients who receive a left internal mammary artery graft. Study Design: Randomized control trial. Place and Duration of study: Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi from June 2009 to Feb 2010. Patients and Methods: The study was conducted on 62 patients who underwent elective coronary artery bypass grafting. The patients were divided into 2 groups: Group A consisted of patients who underwent internal mammary artery harvesting with opened pleura (n=31) while Group B consisted of patients having internal mammary artery harvested with intact pleura (n=31). To monitor pleuro-pulmonary complications, chest radiography was performed routinely 1 day before operation and on the second, fourth and sixth postoperative days. The preoperative, after extubation, and first postoperative day values of partial oxygen pressure (PaO/sub 2/), partial carbon dioxide pressure (PaCO/sub 2/), oxygen (O/sub 2/) saturation and haematocrit were recorded for comparison. The effect of intact pleura on IMA traction was also recorded by serial cardiac enzymes measurement and electrocardiography in the immediate postoperative period. Results: Pleural effusion occurred more often in patients of Group A (35.5% versus 12.9%) which was statistically significant (P 0.038). However, no significant differences were recorded in postoperative respiratory complications. Reoperation for postoperative bleeding and tamponade was done in 6.5% and 3.2% of cases in Group B respectively but none Group A; however it was not statistically significant (P 0.076). The mean postoperative hospital stay was 7.84 days for Group A and 7.58 days for Group B. Conclusion: Pleural integrity during IMA harvesting decreases pleural effusion. Although, no significant differences were recorded in postoperative lung complications, intact pleural technique of IMA

  9. Influence of polymeric microspheres on the myocardial oxygen partial pressure in the beating heart of pigs.

    Science.gov (United States)

    Hiebl, B; Mrowietz, C; Lee, S; Braune, S; Knaut, M; Lendlein, A; Franke, R P; Jung, F

    2011-07-01

    Injection of labeled microspheres is an established method in animal models to analyze the capillary organ blood flow at different time points. However, the microspheres can lead to stenoses of the capillary lumen, which might affect tissue oxygen supply. Our study aimed to investigate the influence of repeated injections of microspheres into the left coronary artery on the tissue oxygen partial pressure (pO(2)) in the downstream supplied myocardium of Göttingen minipigs. Tests (n=6 pigs each) were performed with two differently sized microspheres (ø=10 ± 0.1 μm (M10) or ø=15 ± 0.15 μm (M15)) from polystyrene. The pO(2) was measured in the midmyocardium of the left and right ventricle for 6 min continuously after each of five injections (1 × 10(6) microspheres each). There was a time laps of 12 min between each injection. In addition, the influence of the carrier solution was analyzed solely in the identical time frame. pO(2) decreased significantly in the myocardial area supplied by the ramus interventricularis paraconalis after injection of M15 microspheres. In contrast, the application of the M10 microspheres did not change the myocardial pO(2). This finding suggests to use microspheres with diameters not exceeding 10 μm for the coronary blood flow assessment. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Method for sensing and measuring a concentration or partial pressure of a reactant used in a redox reaction

    Science.gov (United States)

    Findl, E.

    1984-12-21

    A method for sensing or measuring the partial pressure or concentration of an electroactive species used in conjunction with an electrolyte, the method being characterized by providing a constant current between an anode and a cathode of an electrolyte-containing cell, while measuring changes in voltage that occur between either the anode and cathode or between a reference electrode and one of the main electrodes of the cell, thereby to determine the concentration or partial pressure of the electro-active species as a function of said measured voltage changes. The method of the invention can be practiced using either a cell having only an anode and a cathode, or using a cell having an anode and a cathode in combination with a reference electrode. Accurate measurements of small concentrations or partial pressures of electro-active species are obtainable with the method of the invention, by using constant currents of only a few microamperes between the anode and cathode of the cell, while the concentration-determining voltage is measured.

  11. Oxygen Partial Pressure Is a Rate-Limiting Parameter for Cell Proliferation in 3D Spheroids Grown in Physioxic Culture Condition.

    Science.gov (United States)

    Gomes, Aurélie; Guillaume, Ludivine; Grimes, David Robert; Fehrenbach, Jérôme; Lobjois, Valérie; Ducommun, Bernard

    2016-01-01

    The in situ oxygen partial pressure in normal and tumor tissues is in the range of a few percent. Therefore, when studying cell growth in 3D culture systems, it is essential to consider how the physiological oxygen concentration, rather than the one in the ambient air, influences the proliferation parameters. Here, we investigated the effect of reducing oxygen partial pressure from 21% to 5% on cell proliferation rate and regionalization in a 3D tumor spheroid model. We found that 5% oxygen concentration strongly inhibited spheroid growth, changed the proliferation gradient and reduced the 50% In Depth Proliferation index (IDP50), compared with culture at 21% oxygen. We then modeled the oxygen partial pressure profiles using the experimental data generated by culturing spheroids in physioxic and normoxic conditions. Although hypoxia occurred at similar depth in spheroids grown in the two conditions, oxygen partial pressure was a major rate-limiting factor with a critical effect on cell proliferation rate and regionalization only in spheroids grown in physioxic condition and not in spheroids grown at atmospheric normoxia. Our findings strengthen the need to consider conducting experiment in physioxic conditions (i.e., tissue normoxia) for proper understanding of cancer cell biology and the evaluation of anticancer drugs in 3D culture systems.

  12. Discussion on the treatment of cerebral ischemia-reperfusion injuries following intra-arterial thrombolysis

    International Nuclear Information System (INIS)

    Tian Hong; Song Chuan; Fan Ruxiong; Zhou Huchuan; Zhang Yubo; Zang Qiaoli; Zhang Yunquan; Liu Lei

    2011-01-01

    Objective: To investigate the therapeutic method of cerebral ischemia-reperfusion injuries occurred after arterial thrombolytic therapy for acute cerebral infarction. Methods: Thirty-five patients, encountered in authors' Department since Oct. 2005, with cerebral ischemia-reperfusion injuries, which occurred after thrombolytic therapy by using arterial perfusion of urokinase for acute cerebral infarction, were enrolled in this study. The clinical data were retrospectively analyzed. Results: After the thrombolytic therapy, completer or partial recanalization of the occluded cerebral arteries was obtained in 33 cases, while secondary cerebral hemorrhage occurred in 13 cases, of whom cerebral parenchyma bleeding was seen in 2 and hemorrhagic infarction in 11. Different degrees of cerebral edema were found in all 33 cases. Among them significant shift of the midline structures was detected in 18 (54.5%), which was manifested clinically as the worsening of disturbance of consciousness. Strict control of blood pressure, prompt adjustment of dehydration medication, strengthening the cerebral protection measures, cerebral decompression by fenestration, etc. were carried out. All the patients took a turn for the better and were out of danger with remarkable improvement of neurological functions except one patient who died from massive intracerebral hemorrhage. Conclusion: Usually, different degrees of reperfusion injuries will develop after thrombolytic therapy for cerebral arterial infarction. Strictly controlling blood pressure, promptly adjusting dehydration medication and strengthening cerebral protection are the keys to reduce the severity of cerebral reperfusion injuries. (authors)

  13. An experimental study of pressure shadows in partially molten rocks

    Science.gov (United States)

    Qi, Chao; Zhao, Yong-Hong; Kohlstedt, David L.

    2013-11-01

    As a two-phase, solid-melt material flows around rigid particles, melt-depleted and melt-enriched regions (i.e., pressure shadows) develop due to the coupled fluxes of melt and solid driven by pressure gradients around the particles. To study this compaction-decompaction process, samples composed of fine-grained San Carlos olivine plus mid-ocean ridge basalt containing dispersed sub-millimeter-sized, single crystal beads of olivine were deformed in torsion at a temperature of 1473 K and a confining pressure of 300 MPa. Indicated by melt distribution maps obtained from reflected-light optical and backscattered electron microscopy, melt-enriched and melt-depleted regions around the beads became observable at a local shear strain of γ≈1 in samples with an initially homogeneously distributed melt fraction of ϕ≈0.05. The melt-enriched regions (ϕbarhigh≈0.06 to 0.10) and the melt-depleted regions (ϕbarlow≈0.02 to 0.04), extending as far as one radius of the bead, were symmetrically distributed around the bead. The flow field of the olivine matrix determined from crystallographic preferred orientations agrees with theoretical predictions based on two-phase flow analysis. These experiments are the first to produce pressure shadows in partially molten rocks. One implication of this study is that it will be possible to constrain the ratio of bulk to shear viscosity, which is inferred from the distribution of melt using a combination of experimental observations and numerical simulations.

  14. Blood pressure and calf muscle oxygen extraction during plantar flexion exercise in peripheral artery disease.

    Science.gov (United States)

    Luck, J Carter; Miller, Amanda J; Aziz, Faisal; Radtka, John F; Proctor, David N; Leuenberger, Urs A; Sinoway, Lawrence I; Muller, Matthew D

    2017-07-01

    Peripheral artery disease (PAD) is an atherosclerotic vascular disease that affects 200 million people worldwide. Although PAD primarily affects large arteries, it is also associated with microvascular dysfunction, an exaggerated blood pressure (BP) response to exercise, and high cardiovascular mortality. We hypothesized that fatiguing plantar flexion exercise that evokes claudication elicits a greater reduction in skeletal muscle oxygenation (SmO 2 ) and a higher rise in BP in PAD compared with age-matched healthy subjects, but low-intensity steady-state plantar flexion elicits similar responses between groups. In the first experiment, eight patients with PAD and eight healthy controls performed fatiguing plantar flexion exercise (from 0.5 to 7 kg for up to 14 min). In the second experiment, seven patients with PAD and seven healthy controls performed low-intensity plantar flexion exercise (2.0 kg for 14 min). BP, heart rate (HR), and SmO 2 were measured continuously using near-infrared spectroscopy (NIRS). SmO 2 is the ratio of oxygenated hemoglobin to total hemoglobin, expressed as a percent. At fatigue, patients with PAD had a greater increase in mean arterial BP (18 ± 2 vs. vs. 10 ± 2 mmHg, P = 0.029) and HR (14 ± 2 vs. 6 ± 2 beats/min, P = 0.033) and a greater reduction in SmO 2 (-54 ± 10 vs. -12 ± 4%, P = 0.001). However, both groups had similar physiological responses to low-intensity, nonpainful plantar flexion exercise. These data suggest that patients with PAD have altered oxygen uptake and/or utilization during fatiguing exercise coincident with an augmented BP response. NEW & NOTEWORTHY In this laboratory study, patients with peripheral artery disease performed plantar flexion exercise in the supine posture until symptoms of claudication occurred. Relative to age- and sex-matched healthy subjects we found that patients had a higher blood pressure response, a higher heart rate response, and a greater reduction in skeletal muscle oxygenation as

  15. Blood pressure changes in dogs with babesiosis

    Directory of Open Access Journals (Sweden)

    L.S. Jacobson

    2000-07-01

    Full Text Available Systemic arterial blood pressures were measured in 30 dogs with acute babesiosis, 10 each with mild uncomplicated, severe uncomplicated and complicated disease. Ten healthy dogs were used as controls. Hypotension was defined as more than 3 standard deviations below the control mean. Normal mean pressures (±SD were: systolic arterial pressure 151 (±11 mm Hg, diastolic arterial pressure 89 (±8 mm Hg and mean arterial pressure 107 (±10 mmHg. Hypotension was the most frequent abnormality, and increased strikingly in incidence as disease severity increased, with 5/10 dogs in the complicated group being hypotensive for systolic, diastolic and mean arterial pressures, compared with 2/10 in the severe uncomplicated group and 0/10 in the mild uncomplicated group. Systolic, diastolic and mean arterial pressures in the complicated group and severe uncomplicated group, and systolic pressure in the mild uncomplicated group, were significantly lower than in the controls. There were no significant relationships between arterial pressures and age, pulse rate, respiratory rate, temperature, mucous membrane colour or haematocrit. There was a significant negative correlation between arterial pressures and white cell and immature neutrophil counts. Arterial pressures differed significantly between dogs that were clinically collapsed and those that were not, but not between survivors and non-survivors. Pulse pressure (systolic - diastolic was low in 7/10 complicated, 1/10 mild uncomplicated, and 1/10 severe uncomplicated cases, and differed significantly between the complicated and control groups. The high incidence of hypotension in clinically severe babesiosis has important implications for therapy.

  16. Arterial stiffness

    Directory of Open Access Journals (Sweden)

    Ursula Quinn

    2012-09-01

    Full Text Available Measurements of biomechanical properties of arteries have become an important surrogate outcome used in epidemiological and interventional cardiovascular research. Structural and functional differences of vessels in the arterial tree result in a dampening of pulsatility and smoothing of blood flow as it progresses to capillary level. A loss of arterial elastic properties results a range of linked pathophysiological changes within the circulation including increased pulse pressure, left ventricular hypertrophy, subendocardial ischaemia, vessel endothelial dysfunction and cardiac fibrosis. With increased arterial stiffness, the microvasculature of brain and kidneys are exposed to wider pressure fluctuations and may lead to increased risk of stroke and renal failure. Stiffening of the aorta, as measured by the gold-standard technique of aortic Pulse Wave Velocity (aPWV, is independently associated with adverse cardiovascular outcomes across many different patient groups and in the general population. Therefore, use of aPWV has been proposed for early detection of vascular damage and individual cardiovascular risk evaluation and it seems certain that measurement of arterial stiffness will become increasingly important in future clinical care. In this review we will consider some of the pathophysiological processes that result from arterial stiffening, how it is measured and factors that may drive it as well as potential avenues for therapy. In the face of an ageing population where mortality from atheromatous cardiovascular disease is falling, pathology associated with arterial stiffening will assume ever greater importance. Therefore, understanding these concepts for all clinicians involved in care of patients with cardiovascular disease will become vital.

  17. Partial Discharge Measurements in HV Rotating Machines in Dependence on Pressure of Coolant

    Directory of Open Access Journals (Sweden)

    I. Kršňák

    2002-01-01

    Full Text Available The influence of the pressure of the coolant used in high voltage rotating machines on partial discharges occurring in stator insulation is discussed in this paper. The first part deals with a theoretical analysis of the topic. The second part deals with the results obtained on a real generator in industrial conditions. Finally, theoretical assumptions and obtained results are compared.

  18. [Efficacy observation on application of negative pressure therapy in the treatment of superficial partial-thickness scald wound in children].

    Science.gov (United States)

    Shen, Chuan-an; Chai, Jia-ke; Tuo, Xiao-ye; Cai, Jian-hua; Li, Dong-jie; Zhang, Lin; Zhu, Hua; Cai, Jin-dong

    2013-02-01

    To observe the effect of negative pressure therapy in the treatment of superficial partial-thickness scald in children. Three hundred and seven children with superficial partial-thickness scald hospitalized from August 2009 to May 2012 were divided into negative pressure therapy group (NPT, n = 145) and control group (C, n = 162) according to the random number table. Patients in group NPT were treated with negative pressure from within post injury day (PID) 3 to PID 9 (with -16 kPa pressure), while traditional occlusive dressing method was used in group C. Changes in body temperature, wound healing condition, frequency of dressing change were compared between group NPT and group C. Bacterial culture results of wounds were compared before and after treatment in group NPT. Volume of drained transudate per one percent of wound area was recorded in group NPT on PID 1 to PID 3. Data were processed with t test or chi-square test. The incidence of high fever was significantly lower in group NPT (26.9%, 39/145) than in group C (63.6%, 103/162, χ(2) = 41.419, P partial-thickness scald.

  19. Value of systolic pulmonary arterial pressure as a prognostic factor of death in the systemic sclerosis EUSTAR population

    DEFF Research Database (Denmark)

    Hachulla, Eric; Clerson, Pierre; Airò, Paolo

    2015-01-01

    OBJECTIVE: The aim of this study was to assess the prognostic value of systolic pulmonary artery pressure (sPAP) estimated by echocardiography in the multinational European League Against Rheumatism Scleroderma Trial and Research (EUSTAR) cohort. METHODS: Data for patients with echocardiography...

  20. [Arterial sequelae of pregnancy hypertension. Detection by carotid piezogram].

    Science.gov (United States)

    Meyer-Heine, A; Asquer, J C; Lagrue, G

    1989-01-01

    High blood pressure (HTA) is characterized by elevation of pression, but also by modifications of arterial pulse wave. Carotid piezograms were used to evaluate arterial pulse wave. Diastolic blood pressure is significantly correlated with dicrotic notch pressure. The duration of dicrotic notch is negatively correlated with arterial wall elasticity. Thus by carotid piezogram analysis one can determine the respective participation of arterial wall elasticity, peripheral resistance and cardiac factors in blood pressure elevation. Carotid piezograms were measured in 97 women (mean age 27, 8 y), with previous hypertensive pregnancy and apparently cured (mean blood pressure 122-74 mmHg at time of examination). 25 women only had normal piezogram drawing. Abnormalities similar to that of permanent hypertensive disease were observed in most cases. Dicrotic notch duration was significantly reduced and dicrotic notch pressure enhanced; in 34 women both of these abnormalities were present. In conclusion, among women previously hypertensive during pregnancy, even when blood pressure is returned to normal, abnormalities of arterial pulse wave may be present, suggesting that these women are prone to subsequent permanent hypertension.

  1. Theoretical study of the partial molar volume change associated with the pressure-induced structural transition of ubiquitin.

    Science.gov (United States)

    Imai, Takashi; Ohyama, Shusaku; Kovalenko, Andriy; Hirata, Fumio

    2007-09-01

    The partial molar volume (PMV) change associated with the pressure-induced structural transition of ubiquitin is analyzed by the three-dimensional reference interaction site model (3D-RISM) theory of molecular solvation. The theory predicts that the PMV decreases upon the structural transition, which is consistent with the experimental observation. The volume decomposition analysis demonstrates that the PMV reduction is primarily caused by the decrease in the volume of structural voids in the protein, which is partially canceled by the volume expansion due to the hydration effects. It is found from further analysis that the PMV reduction is ascribed substantially to the penetration of water molecules into a specific part of the protein. Based on the thermodynamic relation, this result implies that the water penetration causes the pressure-induced structural transition. It supports the water penetration model of pressure denaturation of proteins proposed earlier.

  2. Control of the threshold voltage by using the oxygen partial pressure in sputter-deposited InGaZnO4 thin-film transistors

    International Nuclear Information System (INIS)

    Ahn, Jeung Sun; Lee, Kwang Bae

    2012-01-01

    We investigate the controllability of the threshold voltage (V th ) by varying the O 2 partial pressure in sputter-deposited of InGaZnO 4 thin-film transistors (IGZO TFTs). We showed that the V th values could be linearly controlled from a depletion-type of V th ∼ -6 V to an enhancement-type of V th ∼ 2 V, without any abrupt change in μ sat , I on/off , and S, by only changing the O 2 partial pressure in a fixed region of the Ar partial pressure. Such V th controllability is thought to be due to the proper reduction of defect states and, in turn, to the preservation of high-performance TFT behavior.

  3. A novel photoplethysmography technique to derive normalized arterial stiffness as a blood pressure independent measure in the finger vascular bed

    International Nuclear Information System (INIS)

    Tanaka, Gohichi; Sawada, Yukihiro; Kato, Yuichi; Yamakoshi, Ken-ichi; Matsumura, Kenta; Maeda, Kimihito; Horiguchi, Masami; Ohguro, Hiroshi

    2011-01-01

    Stiffening of the small artery may be the earliest sign of arteriosclerosis. However, there is no adequate method for directly assessing small arterial stiffness. In this study, the finger arterial elasticity index (FEI) was defined as the parameter n which denotes the curvilinearity of an exponential model of pressure (P)–volume (V a ) relationship (V a = a − b exp (−nP)). For the original estimation, the FEI was calculated from a compliance index from the finger photoplethysmogram whilst occluding the finger. A simple estimation of the FEI was devised by utilizing normalized pulse volume instead of the compliance index. Both estimations yielded close agreement with the exponential model in healthy young participants (study 1: n = 19). Since the FEI was dependent on finger mean blood pressure, normalized finger arterial stiffness index (FSI) was defined as standardized residual from their relationship: mean and standard deviation (SD) of the FSI were 50 ± 10 (study 2: n = 174). The mean coefficient of variation of the FSI for four measurements was 5.72% (study 3: n = 6). The mean and SD of the FSI in seven arteriosclerotic patients were 100.0 ± 13.5. In conclusion, the FEI and FSI by simple estimation are valid and useful for arteriosclerosis research

  4. [Predictive value of central venous-to-arterial carbon dioxide partial pressure difference for fluid responsiveness in septic shock patients: a prospective clinical study].

    Science.gov (United States)

    Liu, Guangyun; Huang, Huibin; Qin, Hanyu; Du, Bin

    2018-05-01

    To evaluate the accuracy of central venous-to-arterial carbon dioxide partial pressure difference (Pcv-aCO 2 ) before and after rapid rehydration test (fluid challenge) in predicting the fluid responsiveness in patients with septic shock. A prospective observation was conducted. Forty septic shock patients admitted to medical intensive care unit (ICU) of Peking Union Medical College Hospital from October 2015 to June 2017 were enrolled. All of the patients received fluid challenge in the presence of invasive hemodynamic monitoring. Heart rate (HR), blood pressure, cardiac index (CI), Pcv-aCO 2 and other physiological variables were recorded at 10 minutes before and immediately after fluid challenge. Fluid responsiveness was defined as an increase in CI greater than 10% after fluid challenge, whereas fluid non-responsiveness was defined as no increase or increase in CI less than 10%. The correlation between Pcv-aCO 2 and CI was explored by Pearson correlation analysis. Receiver operating characteristic (ROC) curves were established to evaluate the discriminatory abilities of baseline and the changes after fluid challenge in Pcv-aCO 2 and other physiological variables to define the fluid responsiveness. The patients were separated into two groups according to the initial value of Pcv-aCO 2 . The cut-off value of 6 mmHg (1 mmHg = 0.133 kPa) was chosen according to previous studies. The discriminatory abilities of baseline and the change in Pcv-aCO 2 (ΔPcv-aCO 2 ) were assessed in each group. A total of 40 patients were finally included in this study. Twenty-two patients responded to the fluid challenge (responders). Eighteen patients were fluid non-responders. There was no significant difference in baseline physiological variable between the two groups. Fluid challenge could increase CI and blood pressure significantly, decrease HR notably and had no effect on Pcv-aCO 2 in fluid responders. In non-responders, blood pressure was increased significantly and CI, HR, Pcv

  5. Obese children and adolescents have elevated nighttime blood pressure independent of insulin resistance and arterial stiffness

    DEFF Research Database (Denmark)

    Hvidt, Kristian N; Olsen, Michael H; Holm, Jens-Christian

    2014-01-01

    BACKGROUND: Insulin resistance has been related to elevated blood pressure (BP) in obese children and may adversely affect the vasculature by arterial stiffening. The objective was to investigate whether daytime and nighttime BP were elevated and related to insulin resistance and arterial stiffness...... in obese children and adolescents. METHODS: Ninety-two obese patients aged 10-18 years were compared with 49 healthy control individuals. Insulin resistance was measured as the homeostatic assessment model (HOMA), and arterial stiffness was measured as carotid-femoral pulse wave velocity (cfPWV). RESULTS......: Mean ± SD daytime systolic BP (SBP) (obese: 125±8.3mm Hg; control: 121±10.1mm Hg; P = 0.03) and nighttime SBP (obese: 108±10.7mm Hg; control: 102±8.2mm Hg; P = 0.0001) were higher in the obese group when compared with the control group. No difference was found in daytime diastolic BP (DBP), whereas...

  6. Analyzing the dependence of oxygen incorporation current density on overpotential and oxygen partial pressure in mixed conducting oxide electrodes.

    Science.gov (United States)

    Guan, Zixuan; Chen, Di; Chueh, William C

    2017-08-30

    The oxygen incorporation reaction, which involves the transformation of an oxygen gas molecule to two lattice oxygen ions in a mixed ionic and electronic conducting solid, is a ubiquitous and fundamental reaction in solid-state electrochemistry. To understand the reaction pathway and to identify the rate-determining step, near-equilibrium measurements have been employed to quantify the exchange coefficients as a function of oxygen partial pressure and temperature. However, because the exchange coefficient contains contributions from both forward and reverse reaction rate constants and depends on both oxygen partial pressure and oxygen fugacity in the solid, unique and definitive mechanistic assessment has been challenging. In this work, we derive a current density equation as a function of both oxygen partial pressure and overpotential, and consider both near and far from equilibrium limits. Rather than considering specific reaction pathways, we generalize the multi-step oxygen incorporation reaction into the rate-determining step, preceding and following quasi-equilibrium steps, and consider the number of oxygen ions and electrons involved in each. By evaluating the dependence of current density on oxygen partial pressure and overpotential separately, one obtains the reaction orders for oxygen gas molecules and for solid-state species in the electrode. We simulated the oxygen incorporation current density-overpotential curves for praseodymium-doped ceria for various candidate rate-determining steps. This work highlights a promising method for studying the exchange kinetics far away from equilibrium.

  7. Does the serum uric acid level have any relation to arterial stiffness or blood pressure in adults with congenital renal agenesis and/or hypoplasia?

    Science.gov (United States)

    Yazici, Raziye; Guney, İbrahim; Altintepe, Lutfullah; Yazici, Mehmet

    2017-01-01

    The relationship between serum uric acid and arterial stiffness or blood pressure is not clear. The serum uric acid level and its association with cardiovascular risk is not well known in patients with reduced renal mass. We aimed to investigate the relation between serum uric acid levels and arterial stiffness and also blood pressure in patients with congenital renal agenesis and/or hypoplasia. In this single center, cross-sectional study, a total of 55 patients (39 (% 70.9) with unilateral small kidney and 16 (%29.1) with renal agenesis) were included. The median age was 35 (21-50) years. The study population was divided into tertiles of serum uric acid (according to 2.40-3.96, 3.97-5.10, and 5.11-9.80 mg/dl cut-off values of serum uric acid levels). Official and 24-h ambulatory non-invasive blood pressures of all patients were measured. The arterial stiffness was assessed by pulse wave velocity (PWV). PWV values were increased from first to third tertile (5.5 ± 0.6, 5.7 ± 0.8, 6.1 ± 0.7, respectively), but this gradual increase between tertiles did not reach significance. Linear regression analyses showed a positive correlation between serum uric acid levels and PWV (β = 0.40, p = 0.010), but no correlation was found between uric acid and daytime systolic blood pressure (β = 0.24, p = 0.345). In congenital renal agenesis/hypoplasia, the serum uric acid level was positively correlated with arterial stiffness, but there was no correlation with blood pressure.

  8. Bipolar impedance-controlled sealing of the pulmonary artery with SealSafe G3 electric current: determination of bursting pressures in an ex vivo model.

    Science.gov (United States)

    Kirschbaum, Andreas; Kunz, Julia; Steinfeldt, Thorsten; Pehl, Anika; Meyer, Christian; Bartsch, Detlef K

    2014-12-01

    In every anatomic lung resection operation, the pulmonary artery itself or its branches must be sealed. This involves either stapling or ligating the vessels. Based on the positive results with the bipolar vessel sealing ≤7 mm in abdominal surgery the present study aimed to evaluate burst pressures of the pulmonary artery after sealing with the sealing instrument SealSafe G3 (Gebrüder Martin & CoKG, Tuttlingen, Germany). The whole pulmonary artery above the pulmonary valve was exposed up to the periphery of the left lung in freshly removed pig heart-lung blocks. A pressure-measuring cylinder was then implanted in the prepared vessel on the side at the main trunk of the pulmonary artery to determine the pressure in the vessel. After either ligation or bipolar sealing of the pulmonary artery, the pneumatic burst pressure (millimeters of mercury) was determined in a water bath. Three groups (n = 12 for each seal type) with different vessel diameters were examined: group 1: 0-6 mm, group 2: 7-12 mm, and group 3: >12 mm. In all cases, vessel sealing was performed with a MARSEAL 5 instrument (Gebrüder Martin & Co KG, Tuttlingen, Germany) and the SealSafe G3 current. The mean burst pressures of the individual groups (ligature and bipolar sealing) were compared using two-tailed, nonparametric Mann-Whitney U test. Significance was defined as P < 0.05. The mean burst pressures in group 1 were measured by 340 ± 13.4 mm Hg with ligature and 205 ± 44.4 mm Hg with bipolar sealing (P < 0.001). In group 2, the mean values obtained were 270 ± 28.2 mm Hg for ligature and 162 ± 36.0 mm Hg for bipolar sealing (P < 0.001). In group 3, the mean burst pressures for bipolar sealing were only 52.1 ± 15.1 mm Hg, whereas those for ligated vessels were 253 ± 46.9 mm Hg (P < 0.001). For this size of vessel the burst pressure was also determined after stapling. The mean value in this case was 230 ± 21.8 mm Hg. In all groups, the mean burst

  9. Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments.

    Science.gov (United States)

    Kono, Kentaro; Kurihara, Daisuke; Suzuki, Yasunori; Ohkubo, Chikahiro

    2014-04-01

    This in vitro study investigated the pressure distribution of the implant-supported removable partial dentures (RPDs) with the stress-breaking attachments under the occlusal force. The experimental model of bilateral missing premolars and molars was modified from a commercial simulation model. Five pressure sensors were embedded near the bilateral first molars, first premolars, and medio-lingual alveolar crest. Two implants were placed near the second molars, and they were connected to the denture base using the following conditions: complete separation between the denture base and implant with cover screws (CRPD), flexible connection with a stress-breaking ball (SBB) attachment, and rigid connection without stress breaking with healing caps (HC). The pressure at five different areas of the soft tissue and the displacement of the RPDs were simultaneously measured, loading up to 50 N. The coefficient of variation (CV) for each connection was calculated from all data of the pressure at five areas to evaluate the pressure distribution. The pressure on medio-lingual alveolar crest and molars of the HC was less than SBB and CRPD. In contrast, the pressure on premolars of SBB was greater than for the HC and CRPD. The CV of SBB was less than that of HC and CRPD. Denture displacement of HC and SBB was less than for CRPD. Within the in vitro limitations, precise denture settlements and pressure distribution under the denture base could be controlled using an SBB attachment. An SBB attachment might be able to protect the implant from harmful force. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  10. Effects of sodium and potassium supplementation on blood pressure and arterial stiffness: a fully controlled dietary intervention study

    NARCIS (Netherlands)

    Gijsbers, L.; Dower, J.I.; Mensink, M.R.; Siebelink, A.E.; Bakker, S.J.L.; Geleijnse, J.M.

    2015-01-01

    We performed a randomised, placebo-controlled, crossover study to examine the effects of sodium and potassium supplementation on blood pressure (BP) and arterial stiffness in untreated (pre)hypertensive individuals. During the study, subjects were on a fully controlled diet that was relatively low

  11. Reversible effects of oxygen partial pressure on genes associated with placental angiogenesis and differentiation in primary-term cytotrophoblast cell culture.

    Science.gov (United States)

    Debiève, F; Depoix, C; Gruson, D; Hubinont, C

    2013-09-01

    Timely regulated changes in oxygen partial pressure are important for placental formation. Disturbances could be responsible for pregnancy-related diseases like preeclampsia and intrauterine growth restriction. We aimed to (i) determine the effect of oxygen partial pressure on cytotrophoblast differentiation; (ii) measure mRNA expression and protein secretion from genes associated with placental angiogenesis; and (iii) determine the reversibility of these effects at different oxygen partial pressures. Term cytotrophoblasts were incubated at 21% and 2.5% O2 for 96 hr, or were switched between the two oxygen concentrations after 48 hr. Real-time PCR and enzyme-linked immunosorbent assays (ELISAs) were used to evaluate cell fusion and differentiation, measuring transcript levels for those genes involved in cell fusion and placental angiogenesis, including VEGF, PlGF, VEGFR1, sVEGFR1, sENG, INHA, and GCM1. Cytotrophoblasts underwent fusion and differentiation in 2.5% O2 . PlGF expression was inhibited while sVEGFR1 expression increased. VEGF and sENG mRNA expressions increased in 2.5% compared to 21% O2 , but no protein was detected in the cell supernatants. Finally, GCM1 mRNA expression increased during trophoblast differentiation at 21% O2 , but was inhibited at 2.5% O2 . These mRNA expression effects were reversed by returning the cells to 21% O2 . Thus, low-oxygen partial pressure does not inhibit term-cytotrophoblast cell fusion and differentiation in vitro. Lowering the oxygen partial pressure from 21% to 2.5% caused normal-term trophoblasts to reversibly modify their expression of genes associated with placental angiogenesis. This suggests that modifications observed in pregnancy diseases such as preeclampsia or growth retardation are probably due to an extrinsic effect on trophoblasts. Copyright © 2013 Wiley Periodicals, Inc.

  12. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    International Nuclear Information System (INIS)

    Unknown

    2001-01-01

    Foster Wheeler Development Corporation is working under DOE contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% while producing near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The unique aspect of the process is that it utilizes a pressurized circulating fluidized bed partial gasifier and does not attempt to consume the coal in a single step. To convert all the coal to syngas in a single step requires extremely high temperatures ((approx)2500 to 2800F) that melt and vaporize the coal and essentially drive all coal ash contaminants into the syngas. Since these contaminants can be corrosive to power generating equipment, the syngas must be cooled to near room temperature to enable a series of chemical processes to clean the syngas. Foster Wheeler's process operates at much lower temperatures that control/minimize the release of contaminants; this eliminates/minimizes the need for the expensive, complicated syngas heat exchangers and chemical cleanup systems typical of high temperature gasification. By performing the gasification in a circulating bed, a significant amount of syngas can still be produced despite the reduced temperature and the circulating bed allows easy scale up to large size plants. Rather than air, it can also operate with oxygen to facilitate

  13. Algunas consideraciones sobre la hipertensión arterial en la diabetes mellitus tipo 2 Some considerations related to arterial high blood pressure in Type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Yanes Quesada

    2009-09-01

    Full Text Available Se realizó una revisión del tema relacionado con la hipertensión arterial en el paciente diabético tipo 2, con el objetivo de actualizar algunos elementos particulares en este grupo de pacientes. Se plantea que su prevalencia es considerablemente más alta que en la población no diabética, donde la hiperinsulinemia y la disfunción endotelial cobran un papel protagónico en su etiopatogenia. La hipertensión arterial en estos pacientes clínicamente se manifiesta como un patrón non dipper, lo que incrementa la morbimortalidad por esta entidad. El tratamiento medicamentoso es habitualmente necesario, y se usan como drogas de primera línea los inhibidores de la enzima convertidora, los antagonistas de los receptores de angiotensina ll y los calcioantagonistas, aunque se pueden utilizar también los diuréticos tiacídicos a dosis bajas.Authors made a review of the topic related to arterial high blood pressure in the patient presenting with Type 2 diabetes mellitus to update some particular elements in this group of patients. We propose that its prevalence is higher than that present in non-diabetic population, where the hyperinsulinism and the endothelial dysfunction have a leading role in its ethiopathogenesis. The arterial high blood pressure in these patients clinically is manifested as a non-dipper pattern increasing the morbidity and mortality. Drug therapy is commonly necessary and as first line-drugs are used the converting-enzyme inhibitors, the agiotensin-II receptors antagonists, and the antagonists-calcium, although the low-dose thiacidic diuretics.

  14. Endomorphins potentiate acid-sensing ion channel currents and enhance the lactic acid-mediated increase in arterial blood pressure: effects amplified in hindlimb ischaemia.

    Science.gov (United States)

    Farrag, Mohamed; Drobish, Julie K; Puhl, Henry L; Kim, Joyce S; Herold, Paul B; Kaufman, Marc P; Ruiz-Velasco, Victor

    2017-12-01

    Chronic limb ischaemia, characterized by inflammatory mediator release and a low extracellular pH, leads to acid-sensing ion channel (ASIC) activation and reflexively increases mean arterial pressure; endomorphin release is also increased under inflammatory conditions. We examined the modulation of ASIC currents by endomorphins in sensory neurons from rats with freely perfused and ligated femoral arteries: peripheral artery disease (PAD) model. Endomorphins potentiated sustained ASIC currents in both groups of dorsal root ganglion neurons, independent of mu opioid receptor stimulation or G protein activation. Intra-arterial administration of lactic acid (to simulate exercising muscle and evoke a pressor reflex), endomorphin-2 and naloxone resulted in a significantly greater pressor response than lactic acid alone, while administration of APETx2 inhibited endomorphin's enhancing effect in both groups. These results suggest a novel role for endomorphins in modulating ASIC function to effect lactic acid-mediated reflex increase in arterial pressure in patients with PAD. Chronic muscle ischaemia leads to accumulation of lactic acid and other inflammatory mediators with a subsequent drop in interstitial pH. Acid-sensing ion channels (ASICs), expressed in thin muscle afferents, sense the decrease in pH and evoke a pressor reflex known to increase mean arterial pressure. The naturally occurring endomorphins are also released by primary afferents under ischaemic conditions. We examined whether high affinity mu opioid receptor (MOR) agonists, endomorphin-1 (E-1) and -2 (E-2), modulate ASIC currents and the lactic acid-mediated pressor reflex. In rat dorsal root ganglion (DRG) neurons, exposure to E-2 in acidic solutions significantly potentiated ASIC currents when compared to acidic solutions alone. The potentiation was significantly greater in DRG neurons isolated from rats whose femoral arteries were ligated for 72 h. Sustained ASIC current potentiation was also observed

  15. SGLT2 inhibitors: their potential reduction in blood pressure.

    Science.gov (United States)

    Maliha, George; Townsend, Raymond R

    2015-01-01

    The sodium glucose co-transporter 2 (SGLT2) inhibitors represent a promising treatment option for diabetes and its common comorbidity, hypertension. Emerging data suggests that the SGLT2 inhibitors provide a meaningful reduction in blood pressure, although the precise mechanism of the blood pressure drop remains incompletely elucidated. Based on current data, the blood pressure reduction is partially due to a combination of diuresis, nephron remodeling, reduction in arterial stiffness, and weight loss. While current trials are underway focusing on cardiovascular endpoints, the SGLT2 inhibitors present a novel treatment modality for diabetes and its associated hypertension as well as an opportunity to elucidate the pathophysiology of hypertension in diabetes. Copyright © 2015 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  16. Blood pressure reactivity to psychological stress and coronary calcification in the Coronary Artery Risk Development in Young Adults Study.

    Science.gov (United States)

    Matthews, Karen A; Zhu, Sha; Tucker, Diane C; Whooley, Mary A

    2006-03-01

    A longstanding hypothesis is that individuals who exhibit large increases in blood pressure during psychological stress are at risk for atherosclerosis. We tested whether blood pressure changes during psychological stress predict subsequent coronary calcification (CaC) in young healthy adults. We evaluated 2816 healthy black and white women, 20 to 35 years of age, from the Coronary Artery Risk Development in Young Adults Study, who were not using medication for hypertension or diabetes in 1987-1988. Participants completed video game and star tracing tasks while their blood pressure was recorded. Thirteen years later (2000-2001), they completed computed tomography measures of CaC. Overall 9.3% (261 of 2816) had CaC present at follow-up. Each 10 mm Hg change in systolic blood pressure during the video game was associated with a 24% increased odds of having CaC at follow-up (unadjusted odds ratio, 1.24; 95% CI, 1.06 to 1.46; P=0.008). This association persisted after adjustment for age, race, sex, education, smoking, alcohol, family history of myocardial infarction, smoking, daily alcohol consumption, body mass index, and resting or baseline blood pressure (odds ratio, 1.31; 95% CI, 1.08 to 1.58; P=0.006). Blood pressure changes during the star tracing task were not associated with subsequent CaC. Blood pressure changes during a video game predicted the presence of CaC 13 years later. To our knowledge, this is the first study that reports blood pressure reactivity to a stressor being related to calcification in the coronary arteries. Blood pressure reactivity may provide useful prognostic information about future risk beyond standard risk factors.

  17. Effect of sulfur dioxide partial pressure on the reaction of iodine, sulfur dioxide and water

    International Nuclear Information System (INIS)

    Nakajima, Hayato; Imai, Yoshiyuki; Kasahara, Seiji; Kubo, Shinji; Onuki, Kaoru

    2007-01-01

    Effect of sulfur dioxide partial pressure on the reaction of iodine, sulfur dioxide and water, which is a unit reaction in the IS process for thermochemical hydrogen production, was studied experimentally at 323 K under iodine saturation. Quasi-equilibrium state was observed in the presence of sulfur dioxide gas at constant pressure. The composition of the poly-hydriodic acid solution formed was discussed assuming an ideal desulfurization by the reverse reaction of the Bunsen reaction. The value of HI/(HI+H 2 O) of the desulfurized solution was large at high sulfur dioxide pressure and reached the maximum of 15.7 ± 0.3 mol%. (author)

  18. Impact of lipopolysaccharide-induced acute inflammation on baroreflex-controlled sympathetic arterial pressure regulation.

    Directory of Open Access Journals (Sweden)

    Takeshi Tohyama

    Full Text Available Lipopolysaccharide (LPS induces acute inflammation, activates sympathetic nerve activity (SNA and alters hemodynamics. Since the arterial baroreflex is a negative feedback system to stabilize arterial pressure (AP, examining the arterial baroreflex function is a prerequisite to understanding complex hemodynamics under LPS challenge. We investigated the impact of LPS-induced acute inflammation on SNA and AP regulation by performing baroreflex open-loop analysis.Ten anesthetized Sprague-Dawley rats were used. Acute inflammation was induced by an intravenous injection of LPS (60 μg/kg. We isolated the carotid sinuses from the systemic circulation and controlled carotid sinus pressure (CSP by a servo-controlled piston pump. We matched CSP to AP to establish the baroreflex closed-loop condition, whereas we decoupled CSP from AP to establish the baroreflex open-loop condition and changed CSP stepwise to evaluate the baroreflex open-loop function. We recorded splanchnic SNA and hemodynamic parameters under baroreflex open- and closed-loop conditions at baseline and at 60 and 120 min after LPS injection.In the baroreflex closed-loop condition, SNA continued to increase after LPS injection, reaching three-fold the baseline value at 120 min (baseline: 94.7 ± 3.6 vs. 120 min: 283.9 ± 31.9 a.u.. In contrast, AP increased initially (until 75 min, then declined to the baseline level. In the baroreflex open-loop condition, LPS reset the neural arc (CSP-SNA relationship upward to higher SNA, while shifted the peripheral arc (SNA-AP relationship downward at 120 min after the injection. As a result, the operating point determined by the intersection between function curves of neural arc and peripheral arc showed marked sympatho-excitation without substantial changes in AP.LPS-induced acute inflammation markedly increased SNA via resetting of the baroreflex neural arc, and suppressed the peripheral arc. The balance between the augmented neural arc and

  19. Impact of lipopolysaccharide-induced acute inflammation on baroreflex-controlled sympathetic arterial pressure regulation.

    Science.gov (United States)

    Tohyama, Takeshi; Saku, Keita; Kawada, Toru; Kishi, Takuya; Yoshida, Keimei; Nishikawa, Takuya; Mannoji, Hiroshi; Kamada, Kazuhiro; Sunagawa, Kenji; Tsutsui, Hiroyuki

    2018-01-01

    Lipopolysaccharide (LPS) induces acute inflammation, activates sympathetic nerve activity (SNA) and alters hemodynamics. Since the arterial baroreflex is a negative feedback system to stabilize arterial pressure (AP), examining the arterial baroreflex function is a prerequisite to understanding complex hemodynamics under LPS challenge. We investigated the impact of LPS-induced acute inflammation on SNA and AP regulation by performing baroreflex open-loop analysis. Ten anesthetized Sprague-Dawley rats were used. Acute inflammation was induced by an intravenous injection of LPS (60 μg/kg). We isolated the carotid sinuses from the systemic circulation and controlled carotid sinus pressure (CSP) by a servo-controlled piston pump. We matched CSP to AP to establish the baroreflex closed-loop condition, whereas we decoupled CSP from AP to establish the baroreflex open-loop condition and changed CSP stepwise to evaluate the baroreflex open-loop function. We recorded splanchnic SNA and hemodynamic parameters under baroreflex open- and closed-loop conditions at baseline and at 60 and 120 min after LPS injection. In the baroreflex closed-loop condition, SNA continued to increase after LPS injection, reaching three-fold the baseline value at 120 min (baseline: 94.7 ± 3.6 vs. 120 min: 283.9 ± 31.9 a.u.). In contrast, AP increased initially (until 75 min), then declined to the baseline level. In the baroreflex open-loop condition, LPS reset the neural arc (CSP-SNA relationship) upward to higher SNA, while shifted the peripheral arc (SNA-AP relationship) downward at 120 min after the injection. As a result, the operating point determined by the intersection between function curves of neural arc and peripheral arc showed marked sympatho-excitation without substantial changes in AP. LPS-induced acute inflammation markedly increased SNA via resetting of the baroreflex neural arc, and suppressed the peripheral arc. The balance between the augmented neural arc and suppressed

  20. Corpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    S. Eichhorn

    2017-01-01

    Full Text Available According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR with an established system (LUCAS II in a pig model. Methods. Pigs (n = 5/group in provoked ventricular fibrillation were left untreated for 5 minutes, after which 15 min of cardiopulmonary resuscitation was performed with chest compressions. After 15 min, defibrillation was performed every 2 min if necessary, and up to 3 doses of adrenaline were given. If there was no return of spontaneous circulation after 25 min, the experiment was terminated. Coronary perfusion pressure, carotid blood flow, end-expiratory CO2, regional oxygen saturation by near infrared spectroscopy, blood gas, and local organ perfusion with fluorescent labelled microspheres were measured at baseline and during resuscitation. Results. Animals treated with Corpuls CPR had significantly higher mean arterial pressures during resuscitation, along with a detectable trend of greater carotid blood flow and organ perfusion. Conclusion. Chest compressions with the Corpuls CPR device generated significantly higher mean arterial pressures than compressions performed with the LUCAS II device.

  1. The effect of O2 partial pressure on the photoluminescence of ZnO thin films grown by pulsed laser deposition

    International Nuclear Information System (INIS)

    Lu, Y.M.; Li, X.P.; Su, S.C.; Cao, P.J.; Jia, F.; Han, S.; Zeng, Y.X.; Liu, W.J.; Zhu, D.L.

    2014-01-01

    In this paper, photoluminescence (PL) of ZnO thin films prepared on c-Al 2 O 3 substrates by the pulsed laser deposition (PLD) method at different O 2 partial pressures is investigated. For all samples, a narrow ultraviolet (UV) emission and a broad visible emission can be observed at room-temperature (RT). With increasing O 2 partial pressures from 0.2 to 5 Pa, the intensity ratio of the UV to visible emissions increases, and the energy positions of the UV emission band shift to the high energy side. It is noted that the visible part includes two emission bands of green luminescence (GL) and yellow luminescence (YL), in which the GL emission is strong at low oxygen pressure and the YL emission becomes dominant at high O 2 partial pressures. The temperature-dependent PL spectra show that the UV emission is composed of two bands labeled FX and FA. The dependences and possible assignments of these PL bands are briefly discussed. - Highlights: • We confirmed that the RT UV emission band is due to two transitions of the FX and FA. • The intensity of the FX and FA emission bands strongly depends on oxygen partial pressures. • We deduced that the acceptor-like defects located in the grain boundaries are responsible for the FA emission. • The visible emission includes the GL related to V O and the YL related to V Zn or O i . • The GL emission strongly affects the UV emission

  2. Effects of simulated microgravity on circadian rhythm of caudal arterial pressure and heart rate in rats and their underlying mechanism

    Directory of Open Access Journals (Sweden)

    Li CHEN

    2016-04-01

    Full Text Available Objective  To explore the effects of simulated microgravity on the circadian rhythm of rats' caudal arterial pressure and heart rate, and their underlying mechanism. Methods  Eighteen male SD rats (aged 8 weeks were randomly assigned to control (CON and tail suspension (SUS group (9 each. Rats with tail suspension for 28 days were adopted as the animal model to simulate microgravity. Caudal arterial pressure and heart rate of rats were measured every 3 hours. The circadian difference of abdominal aorta contraction was measured by aortic ring test. Western blotting was performed to determine and compare the protein expression level of clock genes such as Per2 (Period2, Bmal1 (Aryl hydrocarbon receptor nuclear translocatorlike and dbp (D element binding protein in suprachiasmatic nucleus (SCN and abdominal aorta of rats in CON and SUS group at different time points. Results  Compared with CON group, the caudal arterial pressure, both systolic and diastolic pressure, decreased significantly and the diurnal variability disappeared, meanwhile the heart rate increased obviously and also the diurnal variability disappeared in rats of SUS group. Compared with CON group, the contraction reactivity of abdominal aorta decreased with disappearence of the diurnal variability, and also the clock genes expression in SCN and abdominal aorta showed no diurnal variability in rats of SUS group. Conclusion  Simulated microgravity may lead to circadian rhythm disorders in rats' cardiovascular system, which may be associated with the changes of the clock genes expression. DOI: 10.11855/j.issn.0577-7402.2016.04.06

  3. Central Hemodynamics and Arterial Stiffness in Systemic Sclerosis.

    Science.gov (United States)

    Bartoloni, Elena; Pucci, Giacomo; Cannarile, Francesca; Battista, Francesca; Alunno, Alessia; Giuliani, Marco; Cafaro, Giacomo; Gerli, Roberto; Schillaci, Giuseppe

    2016-12-01

    Although microvascular disease is a hallmark of systemic sclerosis (SSc), a higher prevalence of macrovascular disease and a poorer related prognosis have been reported in SSc than in the general population. The simultaneous assessment of prognostically relevant functional properties of larger and smaller arteries, and their effects on central hemodynamics, has never been performed in SSc using the state-of-the-art techniques. Thirty-four women with SSc (aged 61±15 years, disease duration 17±12 years, and blood pressure 123/70±18/11 mm Hg) and 34 healthy women individually matched by age and mean arterial pressure underwent the determination of carotid-femoral (aortic) and carotid-radial (upper limb) pulse wave velocity (a direct measure of arterial stiffness), aortic augmentation (a measure of the contribution of reflected wave to central pulse pressure), and aortobrachial pulse pressure amplification (brachial/aortic pulse pressure) through applanation tonometry (SphygmoCor). Patients and controls did not differ by carotid-femoral or carotid-radial pulse wave velocity. Aortic augmentation index corrected for a heart rate of 75 bpm (AIx@75) was higher in women with SSc (30.9±16% versus 22.2±12%; P=0.012). Patients also had a lower aortobrachial amplification of pulse pressure (1.22±0.18 versus 1.33±0.25; P=0.041). SSc was an independent predictor of AIx@75 (direct) and pulse pressure amplification (inverse). Among patients, age, mean arterial pressure, and C-reactive protein independently predicted carotid-femoral pulse wave velocity. Age and mean arterial pressure were the only predictors of AIx@75. Women with SSc have increased aortic augmentation and decreased pulse pressure amplification (both measures of the contribution of reflected wave to central waveform) but no changes in aortic or upper limb arterial stiffness. Microvascular involvement occurs earlier than large artery stiffening in SSc. © 2016 American Heart Association, Inc.

  4. Unilateral renal artery stenosis and hypertension. II. Angiographic findings correlated with blood pressure response after surgery

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I; Bergentz, S E; Ericsson, B F; Dymling, J F; Hansson, B G; Hoekfelt, B [Department of Diagnostic Radiography, Surgery and Endocrinology, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    The findings at preoperative nephroanigiography of 42 hypertensive patients with unilateral renal artery stenosis or occlusion were correlated with the blood pressure response following surgery and also with the preoperative renal vein renin activity ratio. A stenosis reducing luminal area by at least 90 per cent (or occlusion) and the presence of collateral circulation are considered to be highly suggestive of renovascular hypertension.

  5. Thermal behaviour of pressure tube under fully and partially voided heating conditions using 19 pin fuel element simulator

    International Nuclear Information System (INIS)

    Yadav, Ashwini K.; Kumar, Ravi; Gupta, Akhilesh; Chatterjee, B.; Mukhopadhya, D.; Lele, H.G.

    2011-01-01

    In a nuclear reactor temperature can rise drastically during LOCA due to failure of heat transportation system and subsequently leads to mechanical deformations like sagging, ballooning and breaching of pressure tube. To understand the phenomenon an experiment has been carried out using 19 pin fuel element simulator. Main purpose of the experiment was to trace temperature profiles over the pressure tube, calandria tube and clad tubes of 220 MWe Indian Pressurised Heavy Water Reactor (IPHWR). The symmetrical heating of pressure tube of 1 m length was done through resistance heating of 19 pins under 13.5 kW power using a rectifier and the variation of temperatures over the circumference of pressure tube (PT), calandria tube (CT) and clad tubes were measured. The sagging of pressure tube was initiated at 460 deg C temperature and highest temperature attained was 650 deg C. The highest temperature attained by clad tubes was 680 deg C (over outer ring) and heat is dissipated to calandria vessel mainly due to radiation and natural convection. Again to simulate partially voided conditions, asymmetrical heating of pressure was carried out by injecting 8 kW power to upper 8 pins of fuel simulator. A maximum temperature difference of 295 deg C was observed over the circumference of pressure tube which highlights the magnitude of thermal stresses and its role in breaching of pressure tube under partially voided conditions. Integrity of pressure tube was retained during both symmetrical and asymmetrical heatup conditions. (author)

  6. Influence of N{sub 2} partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N{sub 2} vacuum arc discharge

    Energy Technology Data Exchange (ETDEWEB)

    Naddaf, M., E-mail: ascientific24@aec.org.sy [Department of Molecular Biology and Biotechnology, Atomic Energy Commission of Syria (AECS), P.O. Box 6091, Damascus (Syrian Arab Republic); Abdallah, B. [Department of Physics, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); Ahmad, M. [IBA Laboratory, Department of Chemistry, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); A-Kharroub, M. [Department of Physics, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic)

    2016-08-15

    The influence of N{sub 2} partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N{sub 2} + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N{sub 2} partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N{sub 2} partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N{sub 2} partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N{sub 2} partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N{sub 2} partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N{sub 2} partial pressure.

  7. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    2018-01-01

    Full Text Available Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min. Resumo: Objetivo: Diversos relatos alegam que a pressão arterial (PA na artéria radial poderá subestimar a PA precisa em pacientes gravemente doentes. Aqui, avaliamos diferenças na pressão arterial média (PAM entre a artéria radial e femoral durante cirurgia cardíaca pediátrica para determinar a eficácia do

  8. Evaluation of arterial blood gases and arterial blood pressures in brachycephalic dogs.

    Science.gov (United States)

    Hoareau, G L; Jourdan, G; Mellema, M; Verwaerde, P

    2012-01-01

    Brachycephalic dogs (BD) are prone to congenital upper airway obstruction (brachycephalic syndrome, BS). In humans suffering from sleep apnea, upper airway obstruction is known to cause hypertension. There is no information regarding the influence of BS in dogs on cardiorespiratory physiology. BD are prone to lower P(a) O(2), higher P(a) CO (2), and hypertension compared with meso- or dolicocephalic dogs (MDD). Eleven BD and 11 MDD. After a questionnaire was completed by the owner, a physical examination was performed. Height and thoracic circumferences were measured. Arterial blood gases, electrolyte concentrations, and packed cell volume (PCV) were measured. Systolic (SAP), mean (MAP), and diastolic (DAP) arterial blood pressure recordings were performed. A total of 7 French and 4 English bulldogs met the inclusion criteria. The control group consisted in 6 Beagles, 2 mixed breed dogs, 1 Staffordshire Bull Terrier, 1 Parson Russell Terrier, and 1 Australian Cattle Dog. Statistically, BD had lower P(a) O(2), higher P(a) CO2, and higher PCV when compared with controls (86.2 ± 15.9 versus 100.2 ± 12.6 mmHg, P = .017; 36.3 ± 4.6 versus 32.7 ± 2.6 mmHg, P = .019; 48.2 ± 3.5 versus 44.2 ± 5.4%, P = .026, respectively). Also, they had significantly higher SAP (177.6 ± 25.0 versus 153.5 ± 21.7 mmHg, P = .013), MAP (123.3 ± 17.1 versus 108.3 ± 12.2 mmHg, P = .014), and DAP (95.3 ± 19.2 versus 83.0 ± 11.5 mmHg, P = .042). BD with a P(a) CO (2) >35 mmHg were significantly older than those with a P(a) CO (2) ≤35 mmHg (58 ± 16 and 30 ± 11 months, P = .004). Results of this study suggest that some BD are prone to lower P(a) O(2), higher P(a) CO (2), and hypertension when compared with MDD. Age may be a contributing factor. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  9. [Treatment of acute respiratory distress syndrome using pressure and volume controlled ventilation with lung protective strategy].

    Science.gov (United States)

    Ge, Ying; Wan, Yong; Wang, Da-qing; Su, Xiao-lin; Li, Jun-ying; Chen, Jing

    2004-07-01

    To investigate the significance and effect of pressure controlled ventilation (PCV) as well as volume controlled ventilation (VCV) by lung protective strategy on respiratory mechanics, blood gas analysis and hemodynamics in patients with acute respiratory distress syndrome (ARDS). Fifty patients with ARDS were randomly divided into PCV and VCV groups with permissive hypercapnia and open lung strategy. Changes in respiratory mechanics, blood gas analysis and hemodynamics were compared between two groups. Peak inspiration pressure (PIP) in PCV group was significantly lower than that in VCV group, while mean pressure of airway (MPaw) was significantly higher than that in VCV after 24 hours mechanical ventilation. After 24 hours mechanical ventilation, there were higher central venous pressure (CVP) and slower heart rate (HR) in two groups, CVP was significantly higher in VCV compared with PCV, and PCV group had slower HR than VCV group, the two groups had no differences in mean blood pressure (MBP) at various intervals. All patients showed no ventilator-induced lung injury. Arterial blood oxygenations were obviously improved in two groups after 24 hours mechanical ventilation, PCV group had better partial pressure of oxygen in artery (PaO2) than VCV group. Both PCV and VCV can improve arterial blood oxygenations, prevent ventilator-induced lung injury, and have less disturbance in hemodynamic parameters. PCV with lung protective ventilatory strategy should be early use for patients with ARDS.

  10. Arterial wave reflection decreases gradually from supine to upright

    DEFF Research Database (Denmark)

    van den Bogaard, Bas; Westerhof, Berend E; Best, Hendrik

    2011-01-01

    BACKGROUND. An increase in total peripheral resistance (TPR) usually increases arterial wave reflection. During passive head-up tilt (HUT), however, arterial wave reflection decreases with increasing TPR. This study addressed whether arterial wave reflection gradually decreases during HUT. METHODS....... In 10 healthy volunteers (22-39 years, nine males), we recorded finger arterial pressures in supine position (0°), and 30°and 70°degrees HUT and active standing (90°). Aortic pressure was constructed from the finger pressure signal and hemodynamics were calculated. Arterial wave reflection...... from 0.9 dyn s/cm(5) at 0? to 1.2, 1.4 and 1.4 dyn s/cm(5) at 30°, 70° and 90° (p wave reflection...

  11. N-butyl Cyanoacrylate Glue Embolization of Arterial Networks to Facilitate Hepatic Arterial Skeletonization before Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Samuelson, Shaun D.; Louie, John D.; Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-06-15

    Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identify subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.

  12. Effects of respiratory alkalosis and acidosis on myocardial blood flow and metabolism in patients with coronary artery disease.

    Science.gov (United States)

    Kazmaier, S; Weyland, A; Buhre, W; Stephan, H; Rieke, H; Filoda, K; Sonntag, H

    1998-10-01

    Variation of the arterial carbon dioxide partial pressure (PaCO2) is not uncommon in anesthetic practice. However, little is known about the myocardial consequences of respiratory alkalosis and acidosis, particularly in patients with coronary artery disease. The aim of the current study was to investigate the effects of variation in PaCO2 on myocardial blood flow (MBF), metabolism, and systemic hemodynamics in patients before elective coronary artery bypass graft surgery. In 10 male anesthetized patients, measurements of MBF, myocardial contractility, metabolism, and systemic hemodynamics were made in a randomized sequence at PaCO2 levels of 30, 40, and 50 mmHg, respectively. The MBF was measured using the Kety-Schmidt technique with argon as a tracer. End-diastolic left ventricular pressure and the maximal increase of left ventricular pressure were assessed using a manometer-tipped catheter. The cardiac index significantly changed with varying PaCO2 levels (hypocapnia, - 9%; hypercapnia, 13%). This reaction was associated with inverse changes in systemic vascular resistance index levels. The MBF significantly increased by 15% during hypercapnia, whereas no change was found during hypocapnia. Myocardial oxygen and glucose uptake and the maximal increase of left ventricular pressure were not affected by varying PaCO2 levels. In anesthetized patients with coronary artery disease, short-term variations in PaCO2 have significant effects on MBF but do not influence global myocardial oxygen and glucose uptake. Changes in systemic hemodynamics associated with respiratory alkalosis and acidosis are caused by changes in systemic vascular resistance rather than by alterations in myocardial contractility.

  13. A fluid-structure interaction model of the internal carotid and ophthalmic arteries for the noninvasive intracranial pressure measurement method.

    Science.gov (United States)

    Misiulis, Edgaras; Džiugys, Algis; Navakas, Robertas; Striūgas, Nerijus

    2017-05-01

    Accurate and clinically safe measurements of intracranial pressure (ICP) are crucial for secondary brain damage prevention. There are two methods of ICP measurement: invasive and noninvasive. Invasive methods are clinically unsafe; therefore, safer noninvasive methods are being developed. One of the noninvasive ICP measurement methods implements the balance principle, which assumes that if the velocity of blood flow in both ophthalmic artery segments - the intracranial (IOA) and extracranial (EOA) - is equal, then the acting ICP on the IOA and the external pressure (Pe) on the EOA are also equal. To investigate the assumption of the balance principle, a generalized computational model incorporating a fluid-structure interaction (FSI) module was created and used to simulate noninvasive ICP measurement by accounting for the time-dependent behavior of the elastic internal carotid (ICA) and ophthalmic (OA) arteries and their interaction with pulsatile blood flow. It was found that the extra balance pressure term, which incorporates the hydrodynamic pressure drop between measurement points, must be added into the balance equation, and the corrections on a difference between the velocity of blood flow in the IOA and EOA must be made, due to a difference in the blood flow rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Investigating Cardiac MRI Based Right Ventricular Contractility As A Novel Non-Invasive Metric of Pulmonary Arterial Pressure

    Science.gov (United States)

    Menon, Prahlad G; Adhypak, Srilakshmi M; Williams, Ronald B; Doyle, Mark; Biederman, Robert WW

    2014-01-01

    BACKGROUND We test the hypothesis that cardiac magnetic resonance (CMR) imaging-based indices of four-dimensional (4D) (three dimensions (3D) + time) right ventricle (RV) function have predictive values in ascertaining invasive pulmonary arterial systolic pressure (PASP) measurements from right heart catheterization (RHC) in patients with pulmonary arterial hypertension (PAH). METHODS We studied five patients with idiopathic PAH and two age and sex-matched controls for RV function using a novel contractility index (CI) for amplitude and phase to peak contraction established from analysis of regional shape variation in the RV endocardium over 20 cardiac phases, segmented from CMR images in multiple orientations. RESULTS The amplitude of RV contractility correlated inversely with RV ejection fraction (RVEF; R2 = 0.64, P = 0.03) and PASP (R2 = 0.71, P = 0.02). Phase of peak RV contractility also correlated inversely to RVEF (R2 = 0.499, P = 0.12) and PASP (R2 = 0.66, P = 0.04). CONCLUSIONS RV contractility analyzed from CMR offers promising non-invasive metrics for classification of PAH, which are congruent with invasive pressure measurements. PMID:25624777

  15. Exercise transcutaneous oxygen pressure measurement has good sensitivity and specificity to detect lower extremity arterial stenosis assessed by computed tomography angiography

    OpenAIRE

    Koch, Caroline; Chauve, Emmanuel; Chaudru, S?gol?ne; Le Faucheur, Alexis; Jaquinandi, Vincent; Mah?, Guillaume

    2016-01-01

    Abstract Peripheral artery disease (PAD) is a highly prevalent disease diagnosed by the use of ankle-brachial index (ABI) at rest. In some clinical conditions (diabetes, renal insufficiency, advanced age), ABI can be falsely normal and other tests are required for the PAD diagnosis (American Heart Association statement). This study was conducted to determine the accuracy of exercise transcutaneous oxygen pressure measurement (exercise-TcPo2) in detection of arterial stenosis ?50% using comput...

  16. Protection against high intravascular pressure in giraffe legs

    DEFF Research Database (Denmark)

    Petersen, Karin K; Hørlyck, Arne; Østergaard, Kristine Hovkjær

    2013-01-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination....... All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure....... revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along...

  17. Assessing Collagen and Elastin Pressure-dependent Microarchitectures in Live, Human Resistance Arteries by Label-free Fluorescence Microscopy

    DEFF Research Database (Denmark)

    Bloksgaard, Maria; Thorsted, Bjarne; Brewer, Jonathan R

    2018-01-01

    The pathogenic contribution of resistance artery remodeling is documented in essential hypertension, diabetes and the metabolic syndrome. Investigations and development of microstructurally motivated mathematical models for understanding the mechanical properties of human resistance arteries...... in health and disease have the potential to aid understanding how disease and medical treatments affect the human microcirculation. To develop these mathematical models, it is essential to decipher the relationship between the mechanical and microarchitectural properties of the microvascular wall...... of interest. Image analyses are described for quantifying i) pressure-induced changes in internal elastic lamina branching angles and adventitial collagen straightness using Fiji and ii) collagen and elastin volume densities determined using Ilastik software. Preferably all mechanical and imaging measurements...

  18. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.

    Science.gov (United States)

    Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi

    2011-01-01

    Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.

  19. Effect of telmisartan on arterial distensibility and central blood pressure in patients with mild to moderate hypertension and Type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Roland Asmar

    2001-06-01

    Full Text Available Arterial wall stiffness is an important independent risk factor for cardiovascular disease in hypertensive patients, which is further exacerbated by co-existent diabetes mellitus. Increased arterial stiffness is directly associated with an increase in pulse wave velocity (PWV and indirectly with increased central and peripheral blood pressure. Following a two-week placebo run-in period, 27 patients with mild to moderate essential hypertension and Type 2 diabetes mellitus, were randomised to once daily treatment with either telmisartan 40 mg or placebo for three weeks, and after a two-week washout period, crossed-over to the alternative treatment for a further three weeks. Carotid/femoral and carotid/radial PWV were measured non-invasively using the automatic Complior® device, and central parameters (central blood pressure, pulse contour analysis, and augmentation index were measured using the SphygmoCor® system, at the start and end of each treatment period. Compared with placebo, treatment with telmisartan significantly reduced carotid/femoral PWV (mean adjusted treatment difference -0.95 m/s, 95% confidence intervals: -1.67, -0.23 m/s, p=0.013, as well as peripheral and central diastolic, systolic and pulse pressure. In conclusion, the results of this study show that telmisartan is effective in reducing arterial stiffness in hypertensive patients with Type 2 diabetes mellitus, and may potentially have beneficial effects on cardiovascular outcomes, beyond blood-pressure lowering effects, in this patient group.

  20. Dietary sodium bicarbonate, cool temperatures, and feed withdrawal: impact on arterial and venous blood-gas values in broilers.

    Science.gov (United States)

    Wideman, R F; Hooge, D M; Cummings, K R

    2003-04-01

    Sodium bicarbonate (NaHCO3) has been used successfully in mammals and birds to alleviate pulmonary hypertension. Experiment 1 was designed to provide measurements of arterial and venous blood-gas values from unanesthetized male broilers subjected to a cool temperature (16 degrees C) challenge and fed either a control diet or the same diet alkalinized by dilution with 1% NaHCO3. The incidences of pulmonary hypertension syndrome (PHS, ascites) for broilers fed the control or bicarbonate diets were 15.5 and 10.5%, respectively (P = 0.36, NS). Non-ascitic broilers fed the control diet were heavier than those fed the bicarbonate diet on d 49 (2,671 vs. 2,484 g, respectively); however, other comparisons failed to reveal diet-related differences in heart weight, pulse oximetry values, electrocardiogram amplitudes, or blood-gas values (P > 0.05). When the data were resorted into categories based on right:total ventricular weight ratios (RV:TV) indicative of normal (RV:TV or = 0.28) pulmonary arterial pressures, broilers with elevated RV:TV ratios had poorly oxygenated arterial blood that was more acidic, had high partial pressure of CO2 (PCO2), and had higher HCO3 concentrations when compared with broilers with normal RV:TV ratios. Experiment 2 was conducted to determine if metabolic variations associated with differences in feed intake or environmental temperature potentially could mask an impact of diet composition on blood-gas values. Male broilers maintained at thermoneutral temperature (24 degrees C) either received feed ad libitum or had the feed withdrawn > or = 12 h prior to blood sampling. Broilers fed ad libitum had lower venous saturation of hemoglobin with O2, higher venous PCO2, and higher arterial HCO3 concentrations than broilers subjected to feed withdrawal. Broilers in experiment 2 fed ad libitum and exposed to cool temperatures (16 degrees C) had lower arterial partial pressure of O2 and higher venous PCO2 than broilers fed ad libitum and maintained at 24

  1. Cone pathway function in relation to asymmetric carotid artery stenosis

    DEFF Research Database (Denmark)

    Kofoed, Peter Kristian; Munch, Inger Christine; Holfort, Stig K

    2013-01-01

    Purpose:  To examine retinal function in relation to retinal perfusion pressure in patients with carotid artery stenosis. Methods:  Thirteen patients with carotid artery stenosis without clinical eye disease underwent assessment of ophthalmic artery systolic blood pressure (OSP) by ocular...... pneumoplethysmography, carotid artery obstructive disease by ultrasonography, intraocular pressure by applanation tonometry, retinal perfusion by fluorescein angiography and retinal function by multifocal electroretinography (mfERG). Data analysis compared the eye on the most stenotic side with the fellow eye...... pressure (p = 0.0028, 0.011, 0.041 for N1, P1, N2 implicit times, respectively, and p = 0.0086, 0.016, 0.040 for N1, P1, N2 for amplitudes, respectively, corrected for OSP). Conclusion:  Cone function deviation was observed in clinically healthy eyes on the side with highest degree of carotid artery...

  2. Fatores de risco associados à pressão arterial elevada em adolescentes Risk factors associated with high blood pressure in adolescents

    Directory of Open Access Journals (Sweden)

    Kelly Samara da Silva

    2007-08-01

    Full Text Available Níveis elevados de pressão arterial (PA na infância e adolescência têm sido freqüentemente associados a outros fatores de risco cardiovasculares, além de hipertensão arterial na fase adulta da vida. O presente estudo objetivou identificar fatores de risco associados à PA elevada em adolescentes. Participaram do estudo 674 adolescentes de escolas públicas e privadas, de ambos os sexos (303 rapazes e 371 moças, com idade de 14 a 17 anos (16,5 DP 0,9, da cidade de João Pessoa, Paraíba. Mediante aplicação de um questionário, foram levantadas informações sobre: a indicadores sociodemográficos; b nível de prática da atividade física; c hábitos alimentares; c índice de massa corporal; e fumo e bebidas alcoólicas; e foram realizadas medidas de PA. A prevalência de PA elevada foi de 7,4%, sendo maior nos rapazes (10,2% quando comparada com a das moças (5,1%, p High levels of arterial blood pressure in childhood and adolescence have been often associated with other cardiovascular risk factors apart from arterial hypertension in the adult stage of life. The present study aimed at identifying risk factors associated with high blood pressure in adolescents. The subjects were 674 adolescents from public and private schools in the city of João Pessoa, Paraíba. These subjects were of both sexes (i.e., 303 boys and 371 girls and their ages spanned from 14 to 17 years old. By means of a questionnaire, information about the following aspects was gathered: a socio-demographic status; b physical activity levels; c eating habits; d body mass index; e consumption of alcohol and smoking. Moreover, measurements of arterial pressure (AP showed that the prevalence of high AP was 7.4 %, being higher in boys (10.2% when compared with girls (5.1%, p < 0.01. The results of the multivaried analysis indicated that overweight adolescents displayed from five to six times more chance of having high AP than adolescents with light/normal weight (boys: OR

  3. Physiological Mechanisms Mediating the Coupling between Heart Period and Arterial Pressure in Response to Postural Changes in Humans.

    Science.gov (United States)

    Silvani, Alessandro; Calandra-Buonaura, Giovanna; Johnson, Blair D; van Helmond, Noud; Barletta, Giorgio; Cecere, Anna G; Joyner, Michael J; Cortelli, Pietro

    2017-01-01

    The upright posture strengthens the coupling between heart period (HP) and systolic arterial pressure (SAP) consistently with a greater contribution of the arterial baroreflex to cardiac control, while paradoxically decreasing cardiac baroreflex sensitivity (cBRS). To investigate the physiological mechanisms that mediate the coupling between HP and SAP in response to different postures, we analyzed the cross-correlation functions between low-frequency HP and SAP fluctuations and estimated cBRS with the sequence technique in healthy male subjects during passive head-up tilt test (HUTT, n = 58), during supine wakefulness, supine slow-wave sleep (SWS), and in the seated and active standing positions ( n = 8), and during progressive loss of 1 L blood ( n = 8) to decrease central venous pressure in the supine position. HUTT, SWS, the seated, and the standing positions, but not blood loss, entailed significant increases in the positive correlation between HP and the previous SAP values, which is the expected result of arterial baroreflex control, compared with baseline recordings in the supine position during wakefulness. These increases were mirrored by increases in the low-frequency variability of SAP in each condition but SWS. cBRS decreased significantly during HUTT, in the seated and standing positions, and after blood loss compared with baseline during wakefulness. These decreases were mirrored by decreases in the RMSSD index, which reflects cardiac vagal modulation. These results support the view that the cBRS decrease associated with the upright posture is a byproduct of decreased cardiac vagal modulation, triggered by the arterial baroreflex in response to central hypovolemia. Conversely, the greater baroreflex contribution to cardiac control associated with upright posture may be explained, at least in part, by enhanced fluctuations of SAP, which elicit a more effective entrainment of HP fluctuations by the arterial baroreflex. These SAP fluctuations may result

  4. Quantitative angiography of the left anterior descending coronary artery: correlations with pressure gradient and exercise thallium scintigraphy

    International Nuclear Information System (INIS)

    Reiber, J.H.C.; Serruys, P.W.; Slager, C.J.; Erasmus Univ., Rotterdam

    1986-01-01

    In order to evaluate during cardiac catheterization what constitutes a physiologically significant obstruction to blood flow in the human coronary system, computer based quantitative analysis of coronary angiograms was performed in 31 patients with isolated proximal left anterior descending coronary artery disease. The angiographic severity of the stenosis was compared with the transstenotic pressure gradient measured with the dilatation catheter during angioplasty and the results of exercise thallium scintigraphy. A curvilinear relation was found between the pressure gradient across the stenosis (normalized for the mean aortic pressure) and the residual minimal obstruction area (after subtracting the area of the angioplasty catheter). This relation was best fitted by the equation: normalized mean pressure gradient = a + b · log [obstruction area], r = 0.74. The measurements of the percent area stenosis (cut-off 80%) and of the transstenotic pressure gradient (cut-off 0.30) obtained at rest, correctly predicted the occurrence of thallium perfusion defects induced by exercise in 83% of the patients. (Auth.)

  5. Fractal Dimension Analysis of MDCT Images for Quantifying the Morphological Changes of the Pulmonary Artery Tree in Patients with Pulmonary Hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Haitao; Li, Ning; Guo, Lijun; Gao, Fei; Liu, Cheng [Shandong University, Shandong Medical Imaging Research Institute, Shandong (Korea, Republic of)

    2011-06-15

    The aim of this study was to use fractal dimension (FD) analysis on multidetector CT (MDCT) images for quantifying the morphological changes of the pulmonary artery tree in patients with pulmonary hypertension (PH). Fourteen patients with PH and 17 patients without PH as controls were studied. All of the patients underwent contrast-enhanced helical CT and transthoracic echocardiography. The pulmonary artery trees were generated using post-processing software, and the FD and projected image area of the pulmonary artery trees were determined with Image J software in a personal computer. The FD, the projected image area and the pulmonary artery pressure (PAP) were statistically evaluated in the two groups. The FD, the projected image area and the PAP of the patients with PH were higher than those values of the patients without PH (p < 0.05, t-test). There was a high correlation of FD with the PAP (r = 0.82, p < 0.05, partial correlation analysis). There was a moderate correlation of FD with the projected image area (r = 0.49, p < 0.05, partial correlation analysis). There was a correlation of the PAP with the projected image area (r = 0.65, p < 0.05, Pearson correlation analysis). The FD of the pulmonary arteries in the PH patients was significantly higher than that of the controls. There is a high correlation of FD with the PAP.

  6. Fractal Dimension Analysis of MDCT Images for Quantifying the Morphological Changes of the Pulmonary Artery Tree in Patients with Pulmonary Hypertension

    International Nuclear Information System (INIS)

    Sun, Haitao; Li, Ning; Guo, Lijun; Gao, Fei; Liu, Cheng

    2011-01-01

    The aim of this study was to use fractal dimension (FD) analysis on multidetector CT (MDCT) images for quantifying the morphological changes of the pulmonary artery tree in patients with pulmonary hypertension (PH). Fourteen patients with PH and 17 patients without PH as controls were studied. All of the patients underwent contrast-enhanced helical CT and transthoracic echocardiography. The pulmonary artery trees were generated using post-processing software, and the FD and projected image area of the pulmonary artery trees were determined with Image J software in a personal computer. The FD, the projected image area and the pulmonary artery pressure (PAP) were statistically evaluated in the two groups. The FD, the projected image area and the PAP of the patients with PH were higher than those values of the patients without PH (p < 0.05, t-test). There was a high correlation of FD with the PAP (r = 0.82, p < 0.05, partial correlation analysis). There was a moderate correlation of FD with the projected image area (r = 0.49, p < 0.05, partial correlation analysis). There was a correlation of the PAP with the projected image area (r = 0.65, p < 0.05, Pearson correlation analysis). The FD of the pulmonary arteries in the PH patients was significantly higher than that of the controls. There is a high correlation of FD with the PAP.

  7. Treatment of hypertension and metabolic syndrome: lowering blood pressure is not enough for organ protection, new approach-arterial destiffening.

    Science.gov (United States)

    Zimlichman, Reuven

    2014-10-01

    Cardiovascular risk factors (CVRFs) have been shown to induce end organ damage. Until now, the main approach to reduce CVRF-induced end organ damage was by normalization of CVRFs; this approach was found effective to reduce damage and cardiovascular (CV) events. However, a residual risk always remained even when CVRFs were optimally balanced. An additional risk factor which has an immense effect on the progression of end organ damage is aging. Aging is accompanied by gradual stiffening of the arteries which finally leads to CV events. Until recently, the process of arterial aging was considered as unmodifiable, but this has changed. Arterial stiffening caused by the aging process is similar to the changes seen as a result of CVRF-induced arterial damage. Actually, the presence of CVRFs causes faster arterial stiffening, and the extent of damage is proportional to the severity of the CVRF, the length of its existence, the patient's genetic factors, etc. Conventional treatments of osteoporosis and of hormonal decline at menopause are potential additional approaches to positively affect progression of arterial stiffening. The new approach to further decrease progression of arteriosclerosis, thus preventing events, is the prevention of age-associated arterial structural changes. This approach should further decrease age-associated arterial stiffening. A totally new promising approach is to study the possibility of affecting collagen, elastin, and other components of connective tissue that participate in the process of arterial stiffening. Reduction of pulse pressure by intervention in arterial stiffening process by novel methods as breaking collagen cross-links or preventing their formation is an example of future directions in treatment. This field is of enormous potential that might be revolutionary in inducing further significant reduction of cardiovascular events.

  8. Blood pressure and arterial stiffness in obese children and adolescents.

    Science.gov (United States)

    Hvidt, Kristian Nebelin

    2015-03-01

    Obesity, elevated blood pressure (BP) and arterial stiffness are risk factors for cardiovascular disease. A strong relationship exists between obesity and elevated BP in both children and adults. Obesity and elevated BP in childhood track into adult life increasing the risk of cardiovascular disease in adulthood. Ambulatory BP is the most precise measure to evaluate the BP burden, whereas carotid-femoral pulse wave velocity (cfPWV) is regarded as the gold standard for evaluating arterial (i.e. aortic) stiffness. These measures might contribute to a better understanding of obesity's adverse impact on the cardiovascular system, and ultimately a better prevention and treatment of childhood obesity. The overall aim of the present PhD thesis is to investigate arterial stiffness and 24-hour BP in obese children and adolescents, and evaluate whether these measures are influenced by weight reduction. The present PhD thesis is based on four scientific papers.  In a cross-sectional design, 104 severe obese children and adolescents with an age of 10-18 years were recruited when newly referred to the Children's Obesity Clinic, Holbæk University Hospital, and compared to 50 normal weighted age and gender matched control individuals. Ambulatory BP was measured, and cfPWV was investigated in two ways in respect to the distance measure of aorta; the previously recommended length - the so called subtracted distance, and the currently recommended length - the direct distance. In a longitudinal design, the obese patients were re-investigated after one-year of lifestyle intervention at the Children's Obesity Clinic in purpose of reducing the degree of obesity. In the cross-sectional design, the obese group had higher measures of obesity, while matched for age, gender and height, when compared to the control group. In the longitudinal design, 74% of the 72 followed up obese patients experienced a significant weight reduction. CfPWV was dependent on the method used to measure the

  9. Influence of Oxygen Partial Pressure during Processing on the Thermoelectric Properties of Aerosol-Deposited CuFeO₂.

    Science.gov (United States)

    Stöcker, Thomas; Exner, Jörg; Schubert, Michael; Streibl, Maximilian; Moos, Ralf

    2016-03-24

    In the field of thermoelectric energy conversion, oxide materials show promising potential due to their good stability in oxidizing environments. Hence, the influence of oxygen partial pressure during synthesis on the thermoelectric properties of Cu-Delafossites at high temperatures was investigated in this study. For these purposes, CuFeO₂ powders were synthetized using a conventional mixed-oxide technique. X-ray diffraction (XRD) studies were conducted to determine the crystal structures of the delafossites associated with the oxygen content during the synthesis. Out of these powders, films with a thickness of about 25 µm were prepared by the relatively new aerosol-deposition (AD) coating technique. It is based on a room temperature impact consolidation process (RTIC) to deposit dense solid films of ceramic materials on various substrates without using a high-temperature step during the coating process. On these dense CuFeO₂ films deposited on alumina substrates with electrode structures, the Seebeck coefficient and the electrical conductivity were measured as a function of temperature and oxygen partial pressure. We compared the thermoelectric properties of both standard processed and aerosol deposited CuFeO₂ up to 900 °C and investigated the influence of oxygen partial pressure on the electrical conductivity, on the Seebeck coefficient and on the high temperature stability of CuFeO₂. These studies may not only help to improve the thermoelectric material in the high-temperature case, but may also serve as an initial basis to establish a defect chemical model.

  10. Pulmonary arterial hypertension : an update

    NARCIS (Netherlands)

    Hoendermis, E. S.

    2011-01-01

    Pulmonary arterial hypertension (PAH), defined as group 1 of the World Heart Organisation (WHO) classification of pulmonary hypertension, is an uncommon disorder of the pulmonary vascular system. It is characterised by an increased pulmonary artery pressure, increased pulmonary vascular resistance

  11. [Indices of 24-hour monitoring of arterial blood pressure in patients with neurogenic syncope and patients with chronic constitution- dependent hypotension].

    Science.gov (United States)

    Musaeva, Z A; Khapaev, B A; Fedotova, A V; Oknin, V Iu

    1999-01-01

    Clinical-psychologic study, spectral analysis of heart rate variability, 24-h monitoring of arterial pressure (AP) were performed in 20 patients with chronic constitutional arterial hypotension and in 18 patients with neurogenic syncopal states. Both groups were characterised by considerable manifestations of the syndrome of autonomic dystonia, by emotional-personal disorders that correlated with elevated level of slow-waves of the second order in heart rhythms' spectrum. That testified activation of supersegmental sympathetic-adrenal systems. Disorders in sympathetic-parasympathetic correlations were specific in each group. In patients with arterial hypotension disorder of circadian rhythm was observed in the form of superfluous decrease of diastolic AP during sleep. Circadian rhythms in patients with neurogenic syncopes have parameters characteristic for normals showing a preverved chronobiologic AP regulation. A role of the alterations revealed in pathogenesis of arterial hypotensionis discussed.

  12. Influence of isoflurane on the diastolic pressure-flow relationship and critical occlusion pressure during arterial CABG surgery: a randomized controlled trial.

    Science.gov (United States)

    Hinz, José; Mansur, Ashham; Hanekop, Gerd G; Weyland, Andreas; Popov, Aron F; Schmitto, Jan D; Grüne, Frank F G; Bauer, Martin; Kazmaier, Stephan

    2016-01-01

    The effects of isoflurane on the determinants of blood flow during Coronary Artery Bypass Graft (CABG) surgery are not completely understood. This study characterized the influence of isoflurane on the diastolic Pressure-Flow (P-F) relationship and Critical Occlusion Pressure (COP) during CABG surgery. Twenty patients undergoing CABG surgery were studied. Patients were assigned to an isoflurane or control group. Hemodynamic and flow measurements during CABG surgery were performed twice (15 minutes after the discontinuation of extracorporeal circulation (T15) and again 15 minutes later (T30)). The zero flow pressure intercept (a measure of COP) was extrapolated from a linear regression analysis of the instantaneous diastolic P-F relationship. In the isoflurane group, the application of isoflurane significantly increased the slope of the diastolic P-F relationship by 215% indicating a mean reduction of Coronary Vascular Resistance (CVR) by 46%. Simultaneously, the Mean Diastolic Aortic Pressure (MDAP) decreased by 19% mainly due to a decrease in the systemic vascular resistance index by 21%. The COP, cardiac index, heart rate, Left Ventricular End-Diastolic Pressure (LVEDP) and Coronary Sinus Pressure (CSP) did not change significantly. In the control group, the parameters remained unchanged. In both groups, COP significantly exceeded the CSP and LVEDP at both time points. We conclude that short-term application of isoflurane at a sedative concentration markedly increases the slope of the instantaneous diastolic P-F relationship during CABG surgery implying a distinct decrease with CVR in patients undergoing CABG surgery.

  13. Spatial and Temporal Variations in the Partial Pressure and Emission of CO2 and CH4 in and Amazon Floodplain Lake

    Science.gov (United States)

    Forsberg, B. R.; Amaral, J. H.; Barbosa, P.; Kasper, D.; MacIntyre, S.; Cortes, A.; Sarmento, H.; Borges, A. V.; Melack, J. M.; Farjalla, V.

    2015-12-01

    The Amazon floodplain contains a variety of wetland environments which contribute CO2 and CH4 to the regional and global atmospheres. The partial pressure and emission of these greenhouse gases (GHGs) varies: 1) between habitats, 2) seasonally, as the characteristics these habitats changes and 3) diurnally, in response to diurnal stratification. In this study, we investigated the combined influence of these factors on the partial pressure and emission of GHGs in Lago Janauacá, a central Amazon floodplain lake (3o23' S; 60o18' O). All measurements were made between August of 2014 and April of 2015 at two different sites and in three distinct habitats: open water, flooded forest, flooded macrophytes. Concentrations of CO2 and CH4 in air were measured continuously with a cavity enhanced absorption spectrometer, Los Gatos Research´s Ultraportable Greenhouse Gas Analyzer (UGGA). Vertical profiles o pCO2 and pCH4 were measured using the UGGA connected to an electric pump and equilibrator. Diffusive surface emissions were estimated with the UGGA connected to a static floating chamber. To investigate the influence of vertical stratification and mixing on GHG partial pressure and emissions, a meteorological station and submersible sensor chain were deployed at each site. Meteorological sensors included wind speed and direction. The submersible chains included thermistors and oxygen sensors. Depth profiles of partial pressure and diffusive emissions for both CO2 and CH4 varied diurnally, seasonally and between habitats. Both pCO2 and pCH4 were consistently higher in bottom than surface waters with the largest differences occurring at high water when thermal stratification was most stable. Methane emissions and partial pressures were highest at low water while pCO2 and CO2 fluxes were highest during high water periods, with 35% of CO2 fluxes at low water being negative. The highest average surface value of pCO2 (5491 μatm), encountered during rising water, was ~3 times

  14. A comparative study of middle cerebral pressure in dogs and macaques

    Science.gov (United States)

    Symon, Lindsay

    1967-01-01

    1. A comparison has been made of the pressures recorded from pial branches of the middle cerebral artery in dogs and macaques. This pressure has been shown to be between 88 and 95% of femoral arterial pressure in dogs under chloralose anaesthesia, and between 80 and 90% of femoral arterial pressure in macaques similarly anaesthetized. 2. The effect of occlusion of the main vessels in the neck is shown to differ considerably in the two species. Blood pressure within the forebrain of the dog is shown to be largely dependent upon the integrity of the external carotid artery, whereas in the monkey the external carotid artery is without effect in the maintenance of forebrain blood pressure. Occlusion of the four major arteries in the neck is shown to produce a greater effect in the macaque and to be accompanied by signs of medullary ischaemia in this species. 3. After occlusion of the main middle cerebral artery, arterial pressure measured distal to the occlusion depends upon the integrity of collateral vessels from the other cerebral arteries. When only a branch of the middle cerebral artery is occluded, the greater part of the residual blood pressure depends upon anastomoses from other branches of the middle cerebral artery itself. ImagesFig. 1 PMID:4963869

  15. Liver cirrhosis and arterial hypertension

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Møller, Søren

    2006-01-01

    blood pressure. This review considers the alterations in systemic hemodynamics in patients with cirrhosis in relation to essential hypertension and arterial hypertension of the renal origin. Subjects with arterial hypertension (essential, secondary) may become normotensive during the development...... of cirrhosis, and arterial hypertension is rarely manifested in patients with cirrhosis, even in cases with renovascular disease and high circulating renin activity. There is much dispute as to the understanding of homoeostatic regulation in cirrhotic patients with manifest arterial hypertension. This most...

  16. Comportamiento de percentiles de tensión arterial asociados a factores de riesgo en escolares Performance of blood pressure percentiles associated with risk factors in students

    Directory of Open Access Journals (Sweden)

    Javier Jesús Suárez Rivera

    2004-04-01

    Full Text Available Se realizó un estudio prospectivo y descriptivo del universo de escolares desde preescolar hasta 6to. grado de la Escuela Primaria "Jesús Menéndez," de la localidad de Alamar, en el período comprendido desde septiembre de 2000 hasta febrero de 2001, con el objetivo de estimar el comportamiento de los percentiles (pc de tensión arterial, según edad y sexo, así como los factores de riesgo asociados. La muestra quedó constituida por 743 alumnos, a los cuales se les realizó un examen físico que incluyó peso, talla, toma de tensión arterial y una encuesta abierta. Con los datos obtenidos se dividió la población en 4 grupos de estudio según percentiles de tensión arterial: grupo I ( 95 pc, según la literatura extranjera consultada, y se relacionaron con factores de riesgo. El mayor número de escolares estudiados se encontraban con cifras de tensión arterial ubicadas en canales menores al 50 pc (88,83 %, y el factor de riesgo que se encontró con mayor frecuencia fue el antecedente familiar de hipertensión arterial. Solo 6 escolares presentaron cifras de tensión arterial superiores al 95 pc.A prospective descriptive study of students from kindergarten to 6th grade in "Jesús Menendez" elementary school located in Alamar was performed from September 2000 to February 2001 to find out the performance of blood pressure percentiles by age and sex as well as the associated risk factors. The sample was comprised by 743 students who were physically examined, taking into account weight, height, blood pressure and an open survey. The obtained data allowed us to divide the population into 4 groups by blood pressure percentiles; group 1(95 pc according to the reviewed foreign literature and they were related to risk factors. The blood pressure values of the highest number of studied students were under 50 pc (88,83 % and the most frequent risk factors was family history of blood hypertension. Only 6 students had blood pressure value over 95 %.

  17. Beat-to-Beat Blood Pressure Monitor

    Science.gov (United States)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  18. [Arterial hypertension due to altitude].

    Science.gov (United States)

    Domej, Wolfgang; Trapp, Michael; Miggitsch, Eva Maria; Krakher, Tiziana; Riedlbauer, Rita; Roher, Peter; Schwaberger, Günther

    2008-01-01

    The behavior of blood pressure under hypoxic conditions depends on individual factors, altitude and duration of stay at altitude. While most humans are normotensive at higher altitudes, a few will react with moderate hypertension or hypotension. Excessive elevation of arterial blood pressure is not even to be expected below 4,000 m. Rather, several weeks' stay at higher altitude will decrease systolic and diastolic blood pressure at rest as well as during physical exertion. A high-altitude treatment for rehabilitation purposes at moderate altitude may be recommended for patients with cardio-circulatory disorders. Improvements can last several months even after returning to accustomed altitudes. Furthermore, endurance-trained hypertensive patients with pharmacologically controlled arterial blood pressure might be able to participate in mountain treks without additional health risk.

  19. Defining degree of aortic occlusion for partial-REBOA: A computed tomography study on large animals.

    Science.gov (United States)

    Reva, Viktor A; Matsumura, Yosuke; Samokhvalov, Igor M; Pochtarnik, Alexander A; Zheleznyak, Igor S; Mikhailovskaya, Ekaterina M; Morrison, Jonathan J

    2018-04-20

    Partial resuscitative endovascular balloon occlusion of the aorta (P-REBOA) is a modified REBOA technique designed to help ameliorate ischemia-reperfusion injury. The balloon is partially deflated, allowing a proportion of aortic flow distal to the balloon. The aim of this study is to use an ovine model of haemorrhagic shock to correlate the degree of occlusion to several hemodynamic indices. Six sheep weighing 35-46 kg underwent a controlled venous haemorrhage inside a CT scanner until the systolic arterial pressure (AP) dropped to fashion (proximal: r 2  = 0.85, p trend (r 2  = 0.90, p < 0.001). The relationship between percentage occlusion and IBP was sigmoid. MAP values became significantly different at 40-49% occlusion and more (p < 0.01). Furthermore, a drop in the distal pulse pressure from 7.0 (5.5-16.5) to 2.0 (1.5-5.0) mmHg was observed at 80% occlusion. All animals had femoral pulse pressure <5 mmHg at 80% of occlusion and more, which also coincided with the observed loss of pulsatility of the femoral wave-form. Serial CT angiography at an ovine model of haemorrhagic shock demonstrates a correlation between the femoral MAP, F/C pressure gradient and degree of zone I P-REBOA during the staged partial aortic occlusion. These parameters should be considered potential parameters to define the degree of P-REBOA during animal research and clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Right-to-left shunt determination in dog lungs under inhalation anesthesia with rebreathing and non-rebreathing system Determinação de shunt venoso-arterial em pulmões de cães sob anestesia geral inalatória por sistemas com e sem reinalação

    Directory of Open Access Journals (Sweden)

    André Leguthe Rosa

    2006-12-01

    Full Text Available PURPOSE: To investigatge right-to-left shunt determination in dog lungs under inhalantion anesthesia with non-rebreathing and rebreathing systems and fraction of inspired oxygen (F I O2 of 0.9 and 0.4, respectively. METHODS: Two groups of 10 dogs each under inhalation anesthesia with sevoflurane: GI in which it was utilized non-rebreathing semiclosed system and F I O2 = 0.9, and GII in which it was utilized rebreathing semiclosed system and F I O2 = 0.4. The study parameters were: heart rate, medium arterial pressure, right-to-left intrapulmonary shunt, hematocrit, hemoglobin, arterial partial pressure of oxygen, mixed venous partial pressure of oxygen, mixed venous oxygen saturation, arterial partial pressure of carbon dioxide, partial pressure of water in the alveoli. RESULTS: Shunt results were significantly different between the two groups - GI data were higher than GII in all the evaluated moments. Hence, the group with nonrebreathing (GI developed a superior grade of intrapulmonary shunt when compared with the rebreathing group (GII. The partial pressure of water in the alveoli was significantly higher in GII. CONCLUSION: The inhalation anesthesia with non-rebreathing system and F I O2 = 0.9 developed a higher grade of intrapulmonary right-to-left shunt when compared with the rebreathing system and F I O2 = 0.4. The higher humidity in GII contributed to the result.OBJETIVO: Comparar a formação de shunt venoso-arterial em pulmões de cães submetidos a anestesia geral inalatória utilizando-se sistemas de anestesia com e sem reinalação, com fração inspirada de oxigênio de 0,4 e 0,9, respectivamente. MÉTODOS: Empregaram-se 20 cães induzidos com tiopental sódico (30mg/kg e mantidos com sevoflurano (3% e alocados em dois grupos (n=10; os animais de GI foram ventilados com modalidade controlada em sistema semifechado, sem reinalação, F I O2 = 0,9, e os de GII, com modalidade controlada, sistema semifechado, com reinalação e F I O2

  1. The role of adenosine in preconditioning by brief pressure overload in rats.

    Science.gov (United States)

    Huang, Cheng-Hsiung; Tsai, Shen-Kou; Chiang, Shu-Chiung; Lai, Chang-Chi; Weng, Zen-Chung

    2015-08-01

    Brief pressure overload of the left ventricle reduced myocardial infarct (MI) size in rabbits has been previously reported. Its effects in other species are not known. This study investigates effects of pressure overload and the role of adenosine in rats in this study. MI was induced by 40-minute occlusion of the left anterior descending coronary artery followed by 3-hour reperfusion. MI size was determined by triphenyl tetrazolium chloride staining. Brief pressure overload was induced by two 10-minute episodes of partial snaring of the ascending aorta. Systolic left ventricular pressure was raised 50% above the baseline value. Ischemic preconditioning was elicited by two 10-minute coronary artery occlusions. The MI size (mean ± standard deviation), expressed as percentage of area at risk, was significantly reduced in the pressure overload group as well as in the ischemic preconditioning group (17.4 ± 3.0% and 18.2 ± 1.5% vs. 26.6 ± 2.4% in the control group, p overload and ischemic preconditioning (18.3 ± 1.5% and 18.2 ± 2.0%, respectively, p overload of the left ventricle preconditioned rat myocardium against infarction. Because SPT did not significantly alter MI size reduction, our results did not support a role of adenosine in preconditioning by pressure overload in rats. Copyright © 2013. Published by Elsevier B.V.

  2. The Effect of High Dose Cholecalciferol on Arterial Stiffness and Peripheral and Central Blood Pressure in Healthy Humans

    DEFF Research Database (Denmark)

    Bressendorff, Iain; Brandi, Lisbet; Schou, Morten

    2016-01-01

    and central blood pressure and 24-hour ambulatory blood pressure. RESULTS: 22 subjects in the cholecalciferol arm and 18 subjects in the placebo arm completed the 16 weeks of follow-up. There was no difference in changes in PWV, AIx corrected for heart rate or central or peripheral blood pressure between...... and blood pressure in healthy normotensive adults. METHODS: 40 healthy adults were randomised in this double-blinded study to either oral cholecalciferol 3000 IU/day or matching placebo and were followed for 16 weeks to examine any effects on pulse wave velocity (PWV), augmentation index (AIx), peripheral...... the two groups. There was no correlation between serum 25-hydroxy vitamin D and any of these parameters. CONCLUSIONS: Oral cholecalciferol 3000 IU/day does not affect arterial stiffness or blood pressure after 16 weeks of treatment in healthy normotensive adults. TRIAL REGISTRATION: ClinicalTrials.gov NCT...

  3. Association of sleep duration with arterial blood pressure profile of Gujarati Indian adolescents

    Directory of Open Access Journals (Sweden)

    Shaikh Wasim

    2010-01-01

    Full Text Available Background and Aim: Recently, National Health and Nutritional Examination Survey-1 data analysis found short sleep duration as a risk factor for hypertension in the U.S. population. However, since ethnic differences exist in the aetiopathogenesis of diseases, the current study was undertaken to study the effect of sleep duration on the blood pressure profile of Gujarati Indian adolescents. Materials and Methods: A cross-sectional study was conducted on 489 Gujarati Indian adolescents of age group 16-19 years studying in school and colleges in the local population. The participants were assessed for their sleep duration, physical activity status, body composition, blood pressure profile and cardiovascular reactivity. The sleep duration was reported by the subjects as the number of hours they slept on most of the nights in a week over the last one year. The observations of the study were then analyzed after grouping them into: 1 Adequate Sleep Duration at Night, ASDN (≥ 7 hrs and 2 Inadequate Sleep Duration at Night, ISDN (< 7 hrs groups. Student′s unpaired t-test was used to study if any significant difference (P< 0.05 existed between the groups. Results: No significant difference was found in Systolic blood pressure, Diastolic blood pressure, Pulse pressure and Mean arterial pressure between the ASDN group and the ISDN group. Physical activity status also did not differ between the two groups. However, adolescents of ISDN group showed a significantly higher level of adiposity and cardiovascular reactivity as compared to adolescents of ASDN group. Conclusion: Although short sleep duration is associated with a higher level of adiposity and cardiovascular reactivity in Gujarati Indian adolescents, it does not affect the resting blood pressure profile of these adolescents. However, longitudinal studies would be required to observe if the changes in adiposity and cardiovascular reactivity affect these adolescents in later life.

  4. Cardiac index and pulmonary arterial blood pressure during exercise in cases of suspected latent heart failure

    International Nuclear Information System (INIS)

    Agapov, A.A.; Berzak, N.V.; Vladimirov, S.S.

    1987-01-01

    The results studying hemodynamics during maximum physical load (veloeriometry when sitting) for 24 patients examined to avoid heart failure are presented. 19 patients were subjected to coronaroangiography and contrast ventriculography, and 12 patients - to myocardium scintigraphy with 99m Tc-pyrophosphate. It is shown that registration of diaslotic pressure in a pulmonary artery and in a cardiac index permits to diagnose failure in the miocardic function of patients with different heart diseases

  5. Subclavian artery dissection during catheterization in a patient after irradiation

    International Nuclear Information System (INIS)

    Kanazawa, Susumu; Hiraki, Yoshio; Fujie, Shunji; Sato, Nobuo.

    1997-01-01

    A 47-year-old woman with right breast cancer underwent partial mastectomy and had irradiations to the primary and metastatic sites, including the left supraclavicular region. During catheterization of the left internal mammary artery for arterial infusion therapy, the patient developed an iatrogenic dissection and subsequent occlusion of the left subclavian artery. Arterial infusion of tissue plasminogen activator into the artery resulted in recanalization and improvement of clinical signs and symptoms. (author)

  6. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  7. Measurement and prediction of the solubility of acid gases in monoethanolamine solutions at low partial pressures

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, P; Mather, A E

    1977-12-01

    An apparatus for the determination of the solubility of hydrogen sulfide, carbon dioxide, and their mixtures in ethanolamine solutions at low pressures is described. With this apparatus, the solubility of H/sub 2/S, CO/sub 2/ and their mixtures in aqueous solutions of monoethanolamine was measured at partial pressures between 0.001 kPa and 9 kPa at temperatures of 80 and 100/sup 0/C. The results for the mixture were compared with two methods of prediction based on a thermodynamic model. 6 figures, 4 tables.

  8. Intraspecific scaling of arterial blood pressure in the Burmese python.

    Science.gov (United States)

    Enok, Sanne; Slay, Christopher; Abe, Augusto S; Hicks, James W; Wang, Tobias

    2014-07-01

    Interspecific allometric analyses indicate that mean arterial blood pressure (MAP) increases with body mass of snakes and mammals. In snakes, MAP increases in proportion to the increased distance between the heart and the head, when the heart-head vertical distance is expressed as ρgh (where ρ is the density of blood, G: is acceleration due to gravity and h is the vertical distance above the heart), and the rise in MAP is associated with a larger heart to normalize wall stress in the ventricular wall. Based on measurements of MAP in Burmese pythons ranging from 0.9 to 3.7 m in length (0.20-27 kg), we demonstrate that although MAP increases with body mass, the rise in MAP is merely half of that predicted by heart-head distance. Scaling relationships within individual species, therefore, may not be accurately predicted by existing interspecific analyses. © 2014. Published by The Company of Biologists Ltd.

  9. Pharmacological modulation of arterial stiffness.

    LENUS (Irish Health Repository)

    Boutouyrie, Pierre

    2011-09-10

    Arterial stiffness has emerged as an important marker of cardiovascular risk in various populations and reflects the cumulative effect of cardiovascular risk factors on large arteries, which in turn is modulated by genetic background. Arterial stiffness is determined by the composition of the arterial wall and the arrangement of these components, and can be studied in humans non-invasively. Age and distending pressure are two major factors influencing large artery stiffness. Change in arterial stiffness with drugs is an important endpoint in clinical trials, although evidence for arterial stiffness as a therapeutic target still needs to be confirmed. Drugs that independently affect arterial stiffness include antihypertensive drugs, mostly blockers of the renin-angiotensin-aldosterone system, hormone replacement therapy and some antidiabetic drugs such as glitazones. While the quest continues for \\'de-stiffening drugs\\

  10. Nonoperative Management and Novel Imaging for Posterior Circumflex Humeral Artery Injury in Volleyball.

    Science.gov (United States)

    van de Pol, Daan; Planken, R Nils; Terpstra, Aart; Pannekoek-Hekman, Marja; Kuijer, P Paul F M; Maas, Mario

    We report on a 34-yr-old male elite volleyball player with symptomatic emboli in the spiking hand from a partially thrombosed aneurysm of the posterior circumflex humeral artery (PCHA) in his dominant shoulder. At initial diagnosis and follow-up, a combination of time-resolved and high-resolution steady state contrast-enhanced magnetic resonance angiography (CE-MRA) enabled detailed visualization of: (1) emboli that were not detectable by vascular ultrasound; and (2) the PCHA aneurysm, including compression during abduction and external rotation (ABER provocation). At 15-month follow-up, including forced cessation of volleyball activities over the preceding 9 months, the PCHA aneurysm remained unchanged. Central filling defects in the palmar arch and digital arteries resolved over time and affected arterial vessel segments showed postthrombotic changes. Digital blood pressure values improved substantially and almost normalized during follow-up. In conclusion, this case report is the first to show promising results of nonoperative management for a vascular shoulder overuse injury in a professional volleyball player as an alternative to invasive therapeutic options.

  11. Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff.

    Science.gov (United States)

    Fabian, Vratislav; Havlik, Jan; Dvorak, Jan; Kremen, Vaclav; Sajgalik, Pavol; Bellamy, Valentin; Schirger, John A; Sovka, Pavel; Johnson, Bruce D

    2016-12-01

    Systemic arterial blood pressure (BP) is one of the most important parameters of the cardiovascular system. An oscillometric NIBP monitor was specifically designed to measure oscillometric pulsations and mean arterial pressure (MAP) during inflation and deflation of the cuff. Nineteen healthy young (age 23.1±1.7 years; mean±SD) and 35 elderly (83.9±7.9 years; mean±SD) subjects were studied. Differential analysis of MAP during inflation and deflation show mean |ΔMAP|=2.9±2.6 mm Hg in the young group (mean±SD) and |ΔMAP|=6.3±5.2 mm Hg for seniors (mean±SD). There was a significant difference (pdeflation between both groups. In about 50% of elderly subjects |ΔMAP| was higher than 5 mm Hg. Potential clinical relevance of the method needs to be further evaluated.

  12. High CO/sub 2/ partial pressure effects on dark and light CO/sub 2/ fixation and metabolism in Vicia faba leaves

    Energy Technology Data Exchange (ETDEWEB)

    Coudret, A.; Ferron, F.; Laffray, D.

    1985-01-01

    Stomatal opening on Vicia faba can be induced by high CO/sub 2/ partial pressures (10.2%) in dark as well as in light. Stomatal aperture was measured in both cases with a hydrogen porometer. The distribution of /sup 14/C among early products of photosynthesis was studied. Comparisons are made with carboxylations occurring when stomata were open in the dark with CO/sub 2/-free air and in light with 0.034% CO/sub 2/. Results showed that in high CO/sub 2/ partial pressure in light, less radioactivity was incorporated in Calvin cycle intermediates and more in sucrose. ..beta.. carboxylations and photorespiration seemed to be inhibited. In the dark in both CO/sub 2/ conditions, /sup 14/C incorporation was found in malate and aspartate but also in serine and glycerate in high CO/sub 2/ conditions. In light these changes in metabolic pathways may be related with the deleterious effects recorded on leaves after long-term expositions to high partial pressure of CO/sub 2/.

  13. Pressão arterial e discriminação interpessoal: revisão sistemática de estudos epidemiológicos Blood pressure and interpersonal discrimination: systematic review of epidemiologic studies

    Directory of Open Access Journals (Sweden)

    Paulo Francisco Couto

    2012-10-01

    Full Text Available A relação entre pressão arterial e discriminação tem sido investigada recentemente, havendo intensos debates na literatura sobre o tema. Este trabalho objetivou atualizar as revisões de literatura sobre discriminação e pressão arterial ou hipertensão. Foi conduzida pesquisa no PubMed, entre janeiro/2000 e dezembro/2010, incluindo estudos epidemiológicos, que avaliaram a discriminação interpessoal e sua relação com pressão arterial/hipertensão. Os 22 estudos identificados originaram-se dos Estados Unidos; 96% deles empregaram o delineamento transversal, com amostras de conveniência e compostas, em 59% dos casos, exclusivamente por negros. Os instrumentos mais utilizados para aferir discriminação foram Everyday Discrimination Scale e Perceived Racism Scale, enfatizando a discriminação étnico-racial, ocorrida ao longo da vida ou cotidianamente. Nos 22 estudos avaliados, a relação entre discriminação e os desfechos foi analisada 50 vezes. Em 20 (40% resultados, não foi encontrada qualquer associação e, em apenas 15 (30%, observaram-se associações positivas globais, sendo 67% destas estatisticamente significativas. Foram também observadas oito associações inversas, sugerindo que maior exposição à discriminação estaria associada com menor pressão arterial/hipertensão. Os estudos não permitiram apoiar consistentemente a hipótese de que a discriminação está associada à maior pressão arterial. Isto pode ser atribuído, em parte, às limitações dos estudos, relacionadas à mensuração da discriminação e de eventos que podem modificar sua associação com os desfechos. Para consolidar a discriminação como um fator de risco epidemiológico, é necessário utilizar estratégias metodológicas mais rigorosas e revisar os marcos teóricos que propõem relações de causa e efeito entre discriminação e pressão arterial.The relationship between blood pressure and discrimination has been recently

  14. The middle meningeal artery: from clinics to fossils.

    Science.gov (United States)

    Bruner, Emiliano; Sherkat, Shahram

    2008-11-01

    Although research today ranges from molecular to universe scale, many issues regarding gross anatomy remain totally neglected. Within the framework of the endocranial morphogenesis and evolution, understanding the role and variation of the middle meningeal artery relies upon the very limited, scattered, and descriptive information available. The meninges are supplied by branches originating from both the internal and external carotid arteries, often converging in the same networks and hence raising questions on the homology and embryogenesis of these vessels. The middle meningeal artery is often ligated during craniotomies, with no apparent impairment of the cerebral functional processes. The exact physiological role of this extended vascular system, together with the adaptations and selective pressure associated with its evolutionary characterization, have generally been ignored. Anthropologists have made many attempts to quantify and qualify the differences and variation between and within human and nonhuman primates, with scarce results due to the blurry morphology of the vascular networks. Living apes and humans probably have meningeal vessels originating from different embryogenetic processes, further hampering easy phylogenetic comparisons. Generally, monkeys and apes display a larger component derived from the internal carotid artery and its ophthalmic branch. The fossil endocasts partially show the traces of the middle meningeal vessels, allowing some hypotheses on the evolution of these structures. In contrast with modern humans, some extinct groups show a dominance of the posterior branch over the anterior one. The most interesting features are associated with the variation of the middle branch, which supplies the parietal areas. In any case, the most striking difference between the modern and non-modern humans regard the definite increase in the number and complexity of the anastomoses and reticulation in the former. This may be either the simple result

  15. Mechanical design in arteries.

    Science.gov (United States)

    Shadwick, R E

    1999-12-01

    The most important mechanical property of the artery wall is its non-linear elasticity. Over the last century, this has been well-documented in vessels in many animals, from humans to lobsters. Arteries must be distensible to provide capacitance and pulse-smoothing in the circulation, but they must also be stable to inflation over a range of pressure. These mechanical requirements are met by strain-dependent increases in the elastic modulus of the vascular wall, manifest by a J-shaped stress-strain curve, as typically exhibited by other soft biological tissues. All vertebrates and invertebrates with closed circulatory systems have arteries with this non-linear behaviour, but specific tissue properties vary to give correct function for the physiological pressure range of each species. In all cases, the non-linear elasticity is a product of the parallel arrangement of rubbery and stiff connective tissue elements in the artery wall, and differences in composition and tissue architecture can account for the observed variations in mechanical properties. This phenomenon is most pronounced in large whales, in which very high compliance in the aortic arch and exceptionally low compliance in the descending aorta occur, and is correlated with specific modifications in the arterial structure.

  16. Synchronization of tubular pressure oscillations in interacting nephrons

    International Nuclear Information System (INIS)

    Sosnovtseva, O.V.; Postnov, D.E.; Mosekilde, E.; Holstein-Rathlou, N.-H.

    2003-01-01

    The pressure and flow regulation in the individual functional unit of the kidney (the nephron) tends to operate in an unstable regime. For normal rats, the regulation displays regular self-sustained oscillations, but for rats with high blood pressure the oscillations become chaotic. We explain the mechanisms responsible for this behavior and discuss the involved bifurcations. Experimental data show that neighboring nephrons adjust their pressure and flow regulation in accordance with one another. For rats with normal blood pressure, in-phase as well as anti-phase synchronization can be observed. For spontaneously hypertensive rats, indications of chaotic phase synchronization are found. Accounting for a hermodynamics as well as for a vascular coupling between nephrons that share a common interlobular artery, we present a model of the interaction of the pressure and flow regulations between adjacent nephrons. It is shown that this model, with physiologically realistic parameter values, can reproduce the different types of experimentally observed synchronization, including multistability and partial phase synchronization with respect to the slow and fast dynamics

  17. Synchronization of tubular pressure oscillations in interacting nephrons

    Energy Technology Data Exchange (ETDEWEB)

    Sosnovtseva, O.V. E-mail: olga@fysik.dtu.dk; Postnov, D.E.; Mosekilde, E.; Holstein-Rathlou, N.-H

    2003-01-01

    The pressure and flow regulation in the individual functional unit of the kidney (the nephron) tends to operate in an unstable regime. For normal rats, the regulation displays regular self-sustained oscillations, but for rats with high blood pressure the oscillations become chaotic. We explain the mechanisms responsible for this behavior and discuss the involved bifurcations. Experimental data show that neighboring nephrons adjust their pressure and flow regulation in accordance with one another. For rats with normal blood pressure, in-phase as well as anti-phase synchronization can be observed. For spontaneously hypertensive rats, indications of chaotic phase synchronization are found. Accounting for a hermodynamics as well as for a vascular coupling between nephrons that share a common interlobular artery, we present a model of the interaction of the pressure and flow regulations between adjacent nephrons. It is shown that this model, with physiologically realistic parameter values, can reproduce the different types of experimentally observed synchronization, including multistability and partial phase synchronization with respect to the slow and fast dynamics.

  18. Assessment of Nephroprotective Potential of Histochrome during Induced Arterial Hypertension.

    Science.gov (United States)

    Agafonova, I G; Bogdanovich, R N; Kolosova, N G

    2015-12-01

    Magnetic resonance tomography was employed to verify endothelial dysfunction of renal arteries in Wistar and OXYS rats under conditions of induced arterial hypertension. Angiography revealed changes in the size and form of renal arteries of hypertensive animals. In hypertensive rats, histochrome exerted a benevolent therapeutic effect in renal arteries: it decreased BP, diminished thrombus formation in fi ne capillaries and arterioles, demonstrated the anticoagulant properties, partially improved endothelial dysfunction of small renal arteries, and up-regulated the glomerular filtration.

  19. Effect of angiotensin II-induced arterial hypertension on the voltage-dependent contractions of mouse arteries.

    Science.gov (United States)

    Fransen, Paul; Van Hove, Cor E; Leloup, Arthur J A; Schrijvers, Dorien M; De Meyer, Guido R Y; De Keulenaer, Gilles W

    2016-02-01

    Arterial hypertension (AHT) affects the voltage dependency of L-type Ca(2+) channels in cardiomyocytes. We analyzed the effect of angiotensin II (AngII)-induced AHT on L-type Ca(2+) channel-mediated isometric contractions in conduit arteries. AHT was induced in C57Bl6 mice with AngII-filled osmotic mini-pumps (4 weeks). Normotensive mice treated with saline-filled osmotic mini-pumps were used for comparison. Voltage-dependent contractions mediated by L-type Ca(2+) channels were studied in vaso-reactive studies in vitro in isolated aortic and femoral arteries by using extracellular K(+) concentration-response (KDR) experiments. In aortic segments, AngII-induced AHT significantly sensitized isometric contractions induced by elevated extracellular K(+) and depolarization. This sensitization was partly prevented by normalizing blood pressure with hydralazine, suggesting that it was caused by AHT rather than by direct AngII effects on aortic smooth muscle cells. The EC50 for extracellular K(+) obtained in vitro correlated significantly with the rise in arterial blood pressure induced by AngII in vivo. The AHT-induced sensitization persisted when aortic segments were exposed to levcromakalim or to inhibitors of basal nitric oxide release. Consistent with these observations, AngII-treatment also sensitized the vaso-relaxing effects of the L-type Ca(2+) channel blocker diltiazem during K(+)-induced contractions. Unlike aorta, AngII-treatment desensitized the isometric contractions to depolarization in femoral arteries pointing to vascular bed specific responses of arteries to hypertension. AHT affects the voltage-dependent L-type Ca(2+) channel-mediated contraction of conduit arteries. This effect may contribute to the decreased vascular compliance in AHT and explain the efficacy of Ca(2+) channel blockers to reduce vascular stiffness and central blood pressure in AHT.

  20. Low-pressure balloon angioplasty with adjuvant pharmacological therapy in patients with acute ischemic stroke caused by intracranial arterial occlusions

    International Nuclear Information System (INIS)

    Nogueira, Raul G.; Schwamm, Lee H.; Buonanno, Ferdinando S.; Koroshetz, Walter J.; Yoo, Albert J.; Rabinov, James D.; Pryor, Johnny C.; Hirsch, Joshua A.

    2008-01-01

    The use of coronary balloons in the cerebral vasculature is limited due to their poor trackability and increased risk of vessel injury. We report our experience using more compliant elastomer balloons for thrombus resistant to intraarterial (IA) pharmacological and mechanical thrombolysis in acute stroke. We retrospectively analyzed 12 consecutive patients with an occluded intracranial artery treated with angioplasty using a low-pressure elastomer balloon. Angiograms were graded according to the Thrombolysis in Cerebral Infarction (TICI) and Qureshi grading systems. Outcomes were categorized as independent (modified Rankin scale, mRS, score ≤2), dependent (mRS score 3-5), or dead (mRS score 6). Included in the study were 12 patients (mean age 66±17 years, range 31-88 years; mean baseline National Institutes of Health stroke scale score 17±3, range 12-23). The occlusion sites were: internal carotid artery (ICA) terminus (five patients, including two concomitant cervical ICA occlusions), M1 segment (two patients), and basilar artery (two patients). Pharmacological treatment included intravenous (IV) t-PA only (two patients), IA urokinase only (nine patients), both IV t-PA and IA urokinase (one patient), and IV and/or IA eptifibatide (eight patients). Mean time to treatment was 5.9±3.9 h (anterior circulation) and 11.0±7.2 h (posterior circulation). Overall recanalization rate (TICI grade 2/3) was 91.6%. Procedure-related morbidity occurred in one patient (distal posterior inferior cerebellar artery embolus). There were no symptomatic hemorrhages. Outcomes at 90 days were independent (five patients), dependent (three patients) and dead (four patients, all due to progression of stroke with withdrawal of care). Angioplasty of acutely occluded intracranial arteries with low-pressure elastomer balloons results in high recanalization rates with an acceptable degree of safety. Prior use of thrombolytics may increase the chances of recanalization, and glycoprotein IIb

  1. Correction ofvitamin D deficiency/insufficiency and assessment of 24-hour blood pressure parameters in perimenopausal women with arterial hypertension

    Directory of Open Access Journals (Sweden)

    Ludmiła Walerjewna Jankowska

    2014-09-01

    Full Text Available Both arterial hypertension and vitamin D deficiency are highly prevalent in the general population. Aim of the study was to assess blood pressure and its dynamics in 24-hour ambulatory blood pressure monitoring (ABPM while correcting the vitamin D deficiency/insufficiency in perimenopausal women, who have grade 2 arterial hypertension. Material and methods: The study group consisted of 50 premenopausal women [48 (45–50 years] and 52 women in early (up to 5 years postmenopausal period [52 (50–54 years]. Total 25-(OHD blood plasma levels were assessed by immunoenzyme assay using DRG kit (Marburg, Germany. The total 25-(OHD blood plasma levels below 20 ng/ml were considered as vitamin D insufficiency, the concentration of 20–30 ng/ml – as deficiency, and the levels 30–60 ng/ml were considered normal. In the group of women with 25-(OHD deficiency/insufficiency two subgroups were isolated: IB subgroup (n = 25 and IIB (n = 21, which were introduced with treatment algorithm, including cholecalciferol administration at a daily dose of 2000 IU for 3 months. Results: Cholecalciferol therapy at a dose of 2000 IU per day for a period of 3 months has allowed reaching the optimum concentration of vitamin D in 80% of premenopausal hypertensive women, and in 76.2% of women in the early postmenopausal period. Correction of plasma vitamin D deficiency achieved by taking cholecalciferol, while using combined antihypertensive therapy (ramipril + indapamide allows to improve the following parameters assessed in ambulatory blood pressure monitoring in premenopausal women: the mean daytime and nighttime systolic blood pressure, time index of 24-hour and daytime systolic blood pressure, nighttime blood pressure variability, systolic and diastolic blood pressure morning surge, and normalization of nighttime:daytime blood pressure ratio; in postmenopausal women the treatment allowed: the reduction of morning surge of

  2. Unraveling the relationship between arterial flow and intra-aneurysmal hemodynamics.

    Science.gov (United States)

    Morales, Hernán G; Bonnefous, Odile

    2015-02-26

    Arterial flow rate affects intra-aneurysmal hemodynamics but it is not clear how their relationship is. This uncertainty hinders the comparison among studies, including clinical evaluations, like a pre- and post-treatment status, since arterial flow rates may differ at each time acquisition. The purposes of this work are as follows: (1) To study how intra-aneurysmal hemodynamics changes within the full physiological range of arterial flow rates. (2) To provide characteristic curves of intra-aneurysmal velocity, wall shear stress (WSS) and pressure as functions of the arterial flow rate. Fifteen image-based aneurysm models were studied using computational fluid dynamics (CFD) simulations. The full range of physiological arterial flow rates reported in the literature was covered by 11 pulsatile simulations. For each aneurysm, the spatiotemporal-averaged blood flow velocity, WSS and pressure were calculated. Spatiotemporal-averaged velocity inside the aneurysm linearly increases as a function of the mean arterial flow (minimum R(2)>0.963). Spatiotemporal-averaged WSS and pressure at the aneurysm wall can be represented by quadratic functions of the arterial flow rate (minimum R(2)>0.996). Quantitative characterizations of spatiotemporal-averaged velocity, WSS and pressure inside cerebral aneurysms can be obtained with respect to the arterial flow rate. These characteristic curves provide more information of the relationship between arterial flow and aneurysm hemodynamics since the full range of arterial flow rates is considered. Having these curves, it is possible to compare experimental studies and clinical evaluations when different flow conditions are used. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. The effect of siesta in parameters of cardiac structure and in interpretation of ambulatory arterial blood pressure monitoring

    Directory of Open Access Journals (Sweden)

    Marco A.M. Gomes

    2000-04-01

    Full Text Available OBJECTIVE: To evaluate the influence of the siesta in ambulatory blood pressure (BP monitoring and in cardiac structure parameters. METHODS: 1940 ambulatory arterial blood pressure monitoring tests were analyzed (Spacelabs 90207, 15/15 minutes from 7:00 to 22:00 hours and 20/20 minutes from 22:01 to 6.59hours and 21% of the records indicated that the person had taken a siesta (263 woman, 52±14 years. The average duration of the siesta was 118±58 minutes. RESULTS: (average ± standard deviation The average of systolic/diastolic pressures during wakefulness, including the napping period, was less than the average for the period not including the siesta (138±16/85±11 vs 139±16/86±11 mmHg, p5%. CONCLUSION: The siesta influenced the heart structure parameters and from a statistical point of view the average of systolic and diastolic pressures and the respective pressure loads of the wakeful period.

  4. Measurement of Local Partial Pressure of Oxygen in the Brain Tissue under Normoxia and Epilepsy with Phosphorescence Lifetime Microscopy

    Science.gov (United States)

    Zhang, Cong; Bélanger, Samuel; Pouliot, Philippe; Lesage, Frédéric

    2015-01-01

    In this work a method for measuring brain oxygen partial pressure with confocal phosphorescence lifetime microscopy system is reported. When used in conjunction with a dendritic phosphorescent probe, Oxyphor G4, this system enabled minimally invasive measurements of oxygen partial pressure (pO2) in cerebral tissue with high spatial and temporal resolution during 4-AP induced epileptic seizures. Investigating epileptic events, we characterized the spatio-temporal distribution of the "initial dip" in pO2 near the probe injection site and along nearby arterioles. Our results reveal a correlation between the percent change in the pO2 signal during the "initial dip" and the duration of seizure-like activity, which can help localize the epileptic focus and predict the length of seizure. PMID:26305777

  5. Measurement of Local Partial Pressure of Oxygen in the Brain Tissue under Normoxia and Epilepsy with Phosphorescence Lifetime Microscopy.

    Science.gov (United States)

    Zhang, Cong; Bélanger, Samuel; Pouliot, Philippe; Lesage, Frédéric

    2015-01-01

    In this work a method for measuring brain oxygen partial pressure with confocal phosphorescence lifetime microscopy system is reported. When used in conjunction with a dendritic phosphorescent probe, Oxyphor G4, this system enabled minimally invasive measurements of oxygen partial pressure (pO2) in cerebral tissue with high spatial and temporal resolution during 4-AP induced epileptic seizures. Investigating epileptic events, we characterized the spatio-temporal distribution of the "initial dip" in pO2 near the probe injection site and along nearby arterioles. Our results reveal a correlation between the percent change in the pO2 signal during the "initial dip" and the duration of seizure-like activity, which can help localize the epileptic focus and predict the length of seizure.

  6. Growth of MoO3 nanostructured thin films as a function of O2-partial pressure

    Science.gov (United States)

    Sharma, Rabindar Kumar; Kumar, Prabhat; Reddy, G. B.

    2015-06-01

    In this report, we synthesized molybdenum trioxide (α-MoO3) nanostructured thin films (NSTs) with nanoflakes (NFs) on the Ni-coated glass substrates employing plasma assisted sublimation process (PASP) as a function of oxygen partial pressure (PO2). The effect of oxygen partial pressure on structural, morphological, and vibrational properties have been investigated systematically. The structural analysis divulged that all films deposited at different PO2 have pure orthorhombic phase, no impurity phase is detected under the limit of resolution. The morphological studies of samples is carried out by SEM, revealed that features as well as alignment of MoO3 NSTs can be monitored by PO2 and the sample having best features is obtained at 7.5×10-2 Torr. In addition, the more insight information is accomplished by TEM/HRTEM on the best featured sample, which confirmed the single crystalline nature of nanoflakes. The vibrational study of all samples are performed by FTIR, and strongly supports the XRD observations. All the results are in consonance with each other.

  7. The Role of the Pressure in the Partial Regularity Theory for Weak Solutions of the Navier-Stokes Equations

    Science.gov (United States)

    Chamorro, Diego; Lemarié-Rieusset, Pierre-Gilles; Mayoufi, Kawther

    2018-04-01

    We study the role of the pressure in the partial regularity theory for weak solutions of the Navier-Stokes equations. By introducing the notion of dissipative solutions, due to D uchon and R obert (Nonlinearity 13:249-255, 2000), we will provide a generalization of the Caffarelli, Kohn and Nirenberg theory. Our approach sheels new light on the role of the pressure in this theory in connection to Serrin's local regularity criterion.

  8. PARTIAL TRISOMY 4p AND PARTIAL MONOSOMY 13q: CASE REPORT AND A LITERATURE REVIEW.

    Science.gov (United States)

    Puvabanditsin, S; Herrera-Garcia, G; Gengel, N; Hussein, K; February, M; Mayne, J; Mehta, R

    2016-01-01

    We report on a term first born dichorionic-diamniotic twin with deletion of the distal long arm of chromosome 13, partial trisomy of the short arm of chromosome 4, intrauterine growth retardation, and multiple anomalies including microcephaly, colpocephaly, absent corpus callosum, bulbous tip of the nose, large and low set ears, macroglossia, thin upper lip, double outlet right ventricle, atria/ventricular septal defect, cleft mitral valve, pulmonary stenosis, single umbilical artery, multicystic dysplastic left kidney, sacral dimple, anterior displacement of anus, simian creases, abnormal thumb (congenital clasped thumb), overlapping toes, and congenital hypothyroidism. This is the first report of a patient with partial trisomy 4p and partial monosomy 13q.

  9. Evaluation of a three-dimensional ultrasound localisation system incorporating probe pressure correction for use in partial breast irradiation.

    Science.gov (United States)

    Harris, E J; Symonds-Taylor, R; Treece, G M; Gee, A H; Prager, R W; Brabants, P; Evans, P M

    2009-10-01

    This work evaluates a three-dimensional (3D) freehand ultrasound-based localisation system with new probe pressure correction for use in partial breast irradiation. Accuracy and precision of absolute position measurement was measured as a function of imaging depth (ID), object depth, scanning direction and time using a water phantom containing crossed wires. To quantify the improvement in accuracy due to pressure correction, 3D scans of a breast phantom containing ball bearings were obtained with and without pressure. Ball bearing displacements were then measured with and without pressure correction. Using a single scan direction (for all imaging depths), the mean error was <1.3 mm, with the exception of the wires at 68.5 mm imaged with an ID of 85 mm, which gave a mean error of -2.3 mm. Precision was greater than 1 mm for any single scan direction. For multiple scan directions, precision was within 1.7 mm. Probe pressure corrections of between 0 mm and 2.2 mm have been observed for pressure displacements of 1.1 mm to 4.2 mm. Overall, anteroposterior position measurement accuracy increased from 2.2 mm to 1.6 mm and to 1.4 mm for the two opposing scanning directions. Precision is comparable to that reported for other commercially available ultrasound localisation systems, provided that 3D image acquisition is performed in the same scan direction. The existing temporal calibration is imperfect and a "per installation" calibration would further improve the accuracy and precision. Probe pressure correction was shown to improve the accuracy and will be useful for the localisation of the excision cavity in partial breast radiotherapy.

  10. Daily blueberry consumption improves blood pressure and arterial stiffness in postmenopausal women with pre- and stage 1-hypertension: a randomized, double-blind, placebo-controlled clinical trial.

    Science.gov (United States)

    Johnson, Sarah A; Figueroa, Arturo; Navaei, Negin; Wong, Alexei; Kalfon, Roy; Ormsbee, Lauren T; Feresin, Rafaela G; Elam, Marcus L; Hooshmand, Shirin; Payton, Mark E; Arjmandi, Bahram H

    2015-03-01

    Postmenopausal women have a high prevalence of hypertension and often develop arterial stiffness thereby increasing cardiovascular disease risk. Although antihypertensive drug therapies exist, increasing numbers of people prefer natural therapies. In vivo studies and a limited number of clinical studies have demonstrated the antihypertensive and vascular-protective effects of blueberries. To examine the effects of daily blueberry consumption for 8 weeks on blood pressure and arterial stiffness in postmenopausal women with pre- and stage 1-hypertension. This was an 8-week, randomized, double-blind, placebo-controlled clinical trial. Forty-eight postmenopausal women with pre- and stage 1-hypertension recruited from the greater Tallahassee, FL, area participated. Participants were randomly assigned to receive either 22 g freeze-dried blueberry powder or 22 g control powder. Resting brachial systolic and diastolic blood pressures were evaluated and arterial stiffness was assessed using carotid-femoral pulse wave velocity and brachial-ankle pulse wave velocity. C-reactive protein, nitric oxide, and superoxide dismutase were measured at baseline, 4 weeks, and 8 weeks. Statistical analysis was performed using a split plot model of repeated measures analysis of variance. After 8 weeks, systolic blood pressure and diastolic blood pressure (131±17 mm Hg [Pblueberry powder group, whereas there were no changes in the group receiving the control powder. Nitric oxide levels were greater (15.35±11.16 μmol/L; Pblueberry powder group at 8 weeks compared with baseline values (9.11±7.95 μmol/L), whereas there were no changes in the control group. Daily blueberry consumption may reduce blood pressure and arterial stiffness, which may be due, in part, to increased nitric oxide production. Copyright © 2015 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  11. TREATMENT OF INTERNAL CAROTID ARTERY OCCLUSION USING PROXIMAL CEREBRAL PROTECTION DEVICE AND ITS EFFECT ON THE BLOOD PRESSURE DYNAMICS. CLINICAL CASE

    Directory of Open Access Journals (Sweden)

    F. В. Shukurov

    2018-01-01

    Full Text Available In 2016, according to the Ministry of Health of the Russian Federation, about 200 thousand people died from stroke. Strokes are considered as the main cause of disability of the population, causing huge economic damage to the country. One of the most common causes of ischemic stroke is atherosclerosis of the branches of the aortic arch. The most common localization of atherosclerotic plaques is the extracranial section of the carotid arteries – bifurcation and ostium of the common carotid artery and the internal carotid artery. Recanalization of occlusion of the internal carotid artery until recently was an insoluble task for interventional surgery due to the high risk of distal embolization. The invention and use of the proximal cerebral protection device, which ensure the complete cessation of blood flow, has changed the situation. Effect of carotid revascularization on arterial hypertension, due to the effect on the baroreceptors of the carotid plexus by balloon angioplasty, which leads to a reflex decrease in arterial pressure, is an additional advantage of the endovascular technique in some cases. This effect requires further study. One also needs to pay careful attention to the diagnosis and imaging of carotid artery lesions before procedure. This clinical case is the illustration that an adequate assessment of the risk factors for intraoperative complications allows to achieve maximum results of endovascular treatment.

  12. Development of a low tritium partial pressure permeation system for mass transport measurement in lead lithium eutectic

    International Nuclear Information System (INIS)

    Pawelko, R.; Shimada, M.; Katayama, K.; Fukada, S.; Terai, T.

    2014-01-01

    A new experimental system designed to investigate tritium mass transfer properties in materials important to fusion technology is operational at the Safety and Tritium Applied Research (STAR) facility located at the Idaho National Laboratory (INL). The tritium permeation measurement system was developed as part of the Japan/US TITAN collaboration to investigate tritium mass transfer properties in liquid lead lithium eutectic (LLE) alloy. The system is similar to a hydrogen/deuterium permeation measurement system developed at Kyushu University and also incorporates lessons learned from previous tritium permeation experiments conducted at the STAR facility. This paper describes the experimental system that is configured specifically to measure tritium mass transfer properties at low tritium partial pressures. We present preliminary tritium permeation results for α-Fe and α-Fe/LLE samples at 600degC and at tritium partial pressures between 1.0E-3 and 2.4 Pain helium. The preliminary results are compared with literature data. (author)

  13. Percutaneous transluminal angioplasty of the superficial femoral artery by retrograde catheterization via the popliteal artery

    DEFF Research Database (Denmark)

    Tønnesen, K H; Sager, P; Karle, A

    1988-01-01

    We report the results of 50 angioplasty procedures via the popliteal artery. A 3-year follow-up including control of blood pressures at ankle and toe levels show results comparable to reports in the literature. This new approach for angioplasty of the superficial femoral artery and eventually of ...

  14. Foot reflexology can increase vagal modulation, decrease sympathetic modulation, and lower blood pressure in healthy subjects and patients with coronary artery disease.

    Science.gov (United States)

    Lu, Wan-An; Chen, Gau-Yang; Kuo, Cheng-Deng

    2011-01-01

    Complementary and alternative medicine (CAM) has long been used by people to postpone the aging process and to reverse disease progression. Reflexology is a CAM method that involves massage to reflex areas in the feet and hands. This study investigated the effect of foot reflexology (FR) on the autonomic nervous modulation in patients with coronary artery disease (CAD) by using heart rate variability analysis. Seventeen people with angiographically patent coronary arteries and 20 patients with CAD scheduled for coronary artery bypass graft surgery were recruited as the control and CAD groups, respectively. The normalized high-frequency power (nHFP) was used as the index of vagal modulation and the normalized very low-frequency power (nVLFP) as the index of vagal withdrawal and renin-angiotensin modulation. In both control and CAD groups, the nHFP was increased significantly whereas the nVLFP was decreased significantly 30 and 60 minutes after FR, as compared with those before FR. The systolic, diastolic, mean arterial, and pulse pressures were significantly decreased after FR in both groups of participants. In the CAD group, the percentage change in heart rate 30 and 60 minutes after FR was smaller than that in the control, and the percentage change in nVLFP 60 minutes after FR was smaller than that in the control. In conclusion, a higher vagal modulation, lower sympathetic modulation, and lower blood pressure can be observed following 60 minutes of FR in both controls and CAD patients. The magnitude of change in the autonomic nervous modulation in CAD patients was slightly smaller than that in the controls. FR may be used as an efficient adjunct to the therapeutic regimen to increase the vagal modulation and decrease blood pressure in both healthy people and CAD patients.

  15. Mean arterial pressure following prolonged exercise in the heat

    DEFF Research Database (Denmark)

    Gagnon, D; Lynn, A G; Binder, K

    2012-01-01

    benefit to its regulation. We examined MAP (Finometer) in eight trained (T) and eight untrained (UT) individuals prior to, and following, 120 min of cycling at 42 °C with (HYD) and without (DEHY) fluid replacement. Exercise during DEHY induced significant hyperthermia (T: 39.20 ± 0.52 °C vs UT: 38.70 ± 0......Prolonged exercise in the heat without fluid replacement represents a significant challenge to the regulation of mean arterial pressure (MAP). It is unknown, however, if MAP is equally challenged during the post-exercise period, and whether regular endurance exercise training can provide any.......36 °C, P = 0.941) and body weight losses (T: 3.4 ± 1.2% vs UT: 2.7 ± 0.9%, P = 0.332), which did not differ between groups. Although MAP was equally reduced 5 min into the post-exercise period of DEHY (T: -20 ± 11 mmHg vs UT: -22 ± 13 mmHg, P = 0.800), its subsequent recovery was significantly different...

  16. Leg intravenous pressure during head-up tilt.

    NARCIS (Netherlands)

    Groothuis, J.T.; Poelkens, F.; Wouters, C.W.; Kooijman, H.M.; Hopman, M.T.E.

    2008-01-01

    Leg vascular resistance is calculated as the arterial-venous pressure gradient divided by blood flow. During orthostatic challenges it is assumed that the hydrostatic pressure contributes equally to leg arterial, as well as to leg venous pressure. Because of venous valves, one may question whether,

  17. Distribuição de gordura corporal, pressão arterial e níveis de lipídios-lipoproteínas plasmáticas Body fat distribution, blood pressure and plasma lipids and lipoprotein levels

    Directory of Open Access Journals (Sweden)

    Dartagnan Pinto Guedes

    1998-02-01

    Full Text Available OBJETIVO: Investigar associações entre distribuição do tecido adiposo e níveis de pressão arterial e concentrações de lipídios-lipoproteínas plasmáticas, mediante controle de indicadores, quanto à quantidade de gordura corporal e à prática da atividade física. MÉTODOS: Estudo de 62 indivíduos com idades entre 20 e 45 anos. A distribuição do tecido adiposo foi determinada baseando-se na relação circunferência de cintura/quadril (CCQ, e como indicador da quantidade de gordura corporal recorreu-se às informações do índice de massa corporal (IMC, enquanto o nível de prática da atividade física foi estabelecido mediante estimativas do consumo máximo de oxigênio (VO2max. As associações entre CCQ e níveis de pressão arterial e de lipídios-lipoproteínas plasmáticas, com os efeitos do IMC e do VO2max controlados estatisticamente, foram estabelecidas pelo coeficiente de correlação parcial. RESULTADOS: Após correção pelo IMC verificou-se significativa correlação parcial entre a distribuição centrípeta do tecido adiposo e os níveis de pressão arterial, LDL-C e triglicerídios plasmáticos. Entretanto, controlando-se o VO2max, não foram constatadas associações significativas entre CCQ e qualquer variável sangüínea e pressão arterial.CONCLUSÃO: A distribuição centrípeta do tecido adiposo, independente da quantidade de gordura corporal, foi relacionada com concentrações de lipídios-lipoproteínas plasmáticas e níveis de pressão arterial em ambos os sexos. A prática da atividade física parece ser um importante modulador dessa associação, enfatizando seu papel no controle dos fatores de risco predisponentes às doenças cardiovasculares.PURPOSE: To study associations between FAT distribution and blood pressure levels and concentrations of lipids and lipoproteins, irrespective of body fat content and physical activity. METHODS: A sample of 62 subjects of both genders aging 20-45 years-old was

  18. Tobacco smoking strengthens the association of elevated blood pressure with arterial stiffness: the Bogalusa Heart Study.

    Science.gov (United States)

    Yun, Miaoying; Li, Shengxu; Sun, Dianjianyi; Ge, Shaoqing; Lai, Chin-Chih; Fernandez, Camilo; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S

    2015-02-01

    The study assessed the hypothesis that smoking strengthens the association of adult arterial stiffness with long-term cumulative burden of blood pressure (BP) from childhood to adulthood. Tobacco smoking and elevated BPs are important risk factors of vascular stiffness. However, the synergistic effect of these two risk factors is not well established, especially for the long-term burden of elevated BP since childhood. The study cohort consisted of 945 adults (661 whites and 284 blacks, aged 24-43 years) who have BP measured 4-15 times since childhood (aged 4-17 years) in Bogalusa, Louisiana. The adult arterial stiffness was measured as aorta-femoral pulse wave velocity (afPWV); the total area under the curve (AUC) and incremental AUC were used as a measure of long-term burden and trends of BP, respectively. Increased adult afPWV was significantly associated with higher adulthood (P AUC (P AUC (P AUC (P = 0.007) were significantly greater among the current smokers than among the nonsmokers. DBP showed a similar pattern regarding the smoking-BP interaction on afPWV. These results, by showing the synergistic effect of tobacco smoking and long-term BP measures from childhood to adulthood on arterial stiffening process, underscore the importance of undertaking preventive strategies early in life and smoking behavior control.

  19. Arterial hypertension in cirrhosis: arterial compliance, volume distribution, and central haemodynamics

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Fuglsang, S; Bendtsen, F

    2006-01-01

    , was significantly better in hypertensive cirrhotics than in their normotensive counterparts (pportal pressure was similar (HVPG 13 v 15 mm Hg; NS). AC was significantly lower and normal in the arterial hypertensive cirrhotic group (1.07 v 1.39 mm Hg/ml; p...BACKGROUND AND AIMS: Arterial hypertension is a common disorder. Hyperkinetic circulation and reduced effective volaemia are central elements in the haemodynamic dysfunction in cirrhosis. The aim of the present study was to investigate whether cirrhotic patients with arterial hypertension...... are normokinetic and normovolaemic or whether they reveal the same circulatory dysfunction as their normotensive counterparts. MATERIAL AND METHODS: Thirty three patients with arterial hypertension were identified among 648 patients with cirrhosis: 14 in Child class A, 12 in class B, and seven in class C. Controls...

  20. Endovascular treatment of renal artery stenoses

    International Nuclear Information System (INIS)

    Lashari, M.N.

    2015-01-01

    To evaluate the procedure success and effect on hypertension after stenting of incidentally diagnosed atherosclerotic renal artery stenoses. Study Design: An experimental study. Place and Duration of Study: A multicentric study was conducted at the Plastic Surgery and General Hospital, National Medical Center and Ziauddin University Hospital, Karachi, Pakistan from January 2009 to March 2013. Methodology: Hypertension (systolic blood pressure > 160 and diastolic > 90 mmHg with two or more than two medications) with coronary artery disease were initially evaluated for coronary angiography, Renal artery angiography was also endovascular performed and stent was deployed for atherosclerotic renal artery stenosis when found. Blood pressure readings, reduction in need of antihypertensive medication and serum creatinine levels were taken as outcome measures. Patients having renal artery stenoses secondary to connective tissue disorders and fibromuscular dysplasia were excluded. Results: There were 25 patients, 14 (56%) male and 11 (44%) female, with mean age of 49 +- 6 years. Diabetes mellitus, dyslipidemia and smoking were seen in 11 (44%), 10 (40%) and 4 (16%) patients respectively. Renal insufficiency (serum creatinine > 1.5 mg/dl) was seen in one (04%) patient. Bilateral, and isolated right and left renal artery stenoses was seen in 5 (20%), 9 (36%) and 11(44%) patients respectively. Mean percentage of renal artery stenoses was 89%, ranged from 70% to 99% while ostial lesion was found in 20 (80%) patients. A significant decrease in systolic (168.20 +- 9.987 vs. 140.60 +- 5.649 mmHg, p < 0.001) and diastolic blood pressure (88.60 +- 5.50 vs. 77.20 +- 5.017 mmHg, p < 0.001) and reduction of medication (2.72 +- 0.458 vs. 1.5 +- 0.510, p < 0.01) were noted without a change in renal function (p= 0.061) after renal artery stenting. Conclusion: Endovascular stenting of renal artery stenoses in patients with poorly controlled hypertension is a safe and effective treatment